BP 380
80 Watt Photovoltaic Module
High-efficiency photovoltaic module using silicon nitride multicrystalline silicon cells.
Performance
  Rated power (Pmax)         80W
  Power tolerance            ± 5%
  Nominal voltage            12V
  Limited Warranty1          25 years
Configuration
  S BP 380S        Clear universal frame with output cables and
                   polarized Multicontact (MC) connectors
  L BP 380L        Unframed laminate version of BP 380S
  U BP 380U        Clear universal frame with standard junction box
Electrical Characteristics2                      BP 380
  Maximum power (Pmax)3                          80W
  Voltage at Pmax (Vmp)                          17.6V
  Current at Pmax (Imp)                          4.55A
  Warranted minimum Pmax                         76W
  Short-circuit current (Isc)                    4.8A
  Open-circuit voltage (Voc)                     22.1V
  Temperature coefficient of Isc                 (0.065±0.015)%/ °C
  Temperature coefficient of Voc                 -(80±10)mV/°C
  Temperature coefficient of power               -(0.5±0.05)%/ °C
  NOCT (Air 20°C; Sun 0.8kW/m2 ; wind 1m/s)      47±2°C
  Maximum series fuse rating                     15A (20A for U version)
  Maximum system voltage                         600V (U.S. NEC)
                                                 1000V (TÜV Rheinland & IEC 61215 )
Mechanical Characteristics
Dimensions         S,U       Length: 1209mm (47.6”) Width: 537mm (21.1”)              Depth: 50mm (1.97”)
                   L         Length: 1197mm (47.1”) Width: 530mm (20.9”)              Depth: 19mm (0.75”)
Weight             S,U       7.7 kg (17.0 pounds)
                   L         6.1 kg (13.4 pounds)
Solar Cells        S,L,U     36 cells (125mm x 125mm) in a 4x9 matrix connected in series
Output Cables      S,L       RHW AWG# 12 (4mm2) cable with polarized weatherproof DC rated
                             Multicontact connectors; asymmetrical lengths - 900mm (-) and 800mm (+)
Junction Box       U         Standard junction box with 6-terminal connection block; IP 54, accepts PG 13.5,
                             M20, ½ inch conduit, or cable fittings accepting 6-12mm diameter cable.
                             Terminals accept 2.5 to 10mm2 (8 to 14 AWG) wire.
Diodes             S,L,U     Two 9A, 45V Schottky by-pass diodes included
Construction       S,L,U     Front: High-transmission 3mm (1/8th inch) tempered glass; Back: Tedlar;
                             Encapsulant: EVA
Frame              S,U       Clear anodized aluminum alloy type 6063T6 Universal frame; Color: silver
1. Warranty: Power output for 25 years. Freedom from defects in materials and workmanship for 5 years. See our website or your local
   representative for full terms of these warranties.
2. These data represent the performance of typical BP 380 products, and are based on measurements made in accordance with ASTM E1036
   corrected to SRC (STC.)
3. During the stabilization process that occurs during the first few months of deployment, module power may decrease by up to 3% from
   typical Pmax.
BP Solar 2003                                              4032-v1 12/03
Quality and Safety
                    Module power measurements calibrated to World Radiometric Reference through
     ESTI           ESTI (European Solar Test Installation at Ispra, Italy)
                                                                                                                               BP 380 I-V Curves
                    Manufactured in ISO 9001-certified factories; conforms to European Community
                    Directives 89/33/EEC, 73/23/EEC, 93/68/EEC; certified to IEC 61215                                   6.0
                    Framed modules certified by TÜV Rheinland as Safety Class II (IEC 60364)
                    equipment for use in systems up to 1000 VDC                                                          5.0
                                                                                                                                      t=0C
                    Listed by Underwriter’s Laboratories for electrical and fire safety                                  4.0          t=25C
                                                                                                           Current (A)
                                                                                                                                      t=50C
                     (Class C fire rating)                                                                                            t=75C
                                                                                                                         3.0
                    Approved by Factory Mutual Research in NEC Class 1, Division 2,
                    Groups C & D hazardous locations (U)
                                                                                                                         2.0
                                                                                                                         1.0
Qualification Test Parameters                                                                                            0.0
                                                                                                                               0       10          20   30
  Temperature cycling range                       -40°C to +85°C (-40°F to 185°F)
  Humidity freeze, damp heat                      85% RH                                                                                Voltage (V)
  Static load front and back (e.g. wind)          50psf (2400 pascals)
  Front loading (e.g. snow)                       113psf (5400 pascals)
  Hailstone impact                                25mm (1 inch) at 23 m/s (52mph)
Dimensions in brackets are in inches. Unbracketed dimensions are in millimeters. Overall tolerances ±3mm (1/8")
                                                    MC
                                                             +
                                                              MC
                                                                                          Section A-A
Included with each module: self-tapping grounding screw, instruction sheet, and warranty document.
Note: This publication summarizes product warranty and specifications, which are subject to change without notice.
BP Solar 2003                                                     4032-v1 12/03