0% found this document useful (0 votes)
201 views5 pages

Home Ventilation Solutions

Manrose offers rangehood ducting kits for kitchen ventilation that come in three options - through an adjacent wall, through the soffit, or through the roof. The kits include ducting, grilles, and other components to efficiently extract cooking fumes outside. They are designed for easy installation and to reduce noise while complying with relevant standards. Dryer ducting kits are also provided to vent moisture from laundry areas.

Uploaded by

reydudes
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
201 views5 pages

Home Ventilation Solutions

Manrose offers rangehood ducting kits for kitchen ventilation that come in three options - through an adjacent wall, through the soffit, or through the roof. The kits include ducting, grilles, and other components to efficiently extract cooking fumes outside. They are designed for easy installation and to reduce noise while complying with relevant standards. Dryer ducting kits are also provided to vent moisture from laundry areas.

Uploaded by

reydudes
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 5

rangehood & dryer ducting

KITCHEN & LAUNDRY EXTRACTION


www.securimax.co.nz

proven reliable solutions

for the

Kitchen

CLASSIC

Extraction of cooking fumes at their source is essential for moisture and odour reduction in the
home. To help achieve this all kitchen rangehoods should be ducted outside.
Manrose Kitchen Rangehood Ducting Kits are designed to extract fumes efficiently and will fit most
rangehoods. They can be easily installed by the home handyman or a qualified tradesperson.
RANGEHOOD DUCTING KITS
There are three ducting options available for the kitchen rangehood, through an adjacent wall, through the
soffit (under the eave) or up through the roof. Designed with rangehood noise reduction in mind, Manrose
Rangehood Ducting Kits are also fully compliant to AS/NZS 60335.2.80.
THRU WALL

SOFFIT

THRU ROOF

Duct Size

Description

Order Code

Duct Size

Description

Order Code

Duct Size

Description

Order Code

125mm

Rear Vent Gravity Grille

DCT1162

150mm

Thru Soffit

DCT1161

150mm

Thru Roof - Iron

DCT2324

150mm

Thru Soffit - Galv Tube

DCT1259

150mm

Thru Roof - Tiled

DCT2325

150mm

Thru Soffit - Semi Rgid

DCT2323

150mm

Top & Rear Vent


Weatherproof Cowl

DCT2592

For added weather protection use the


weatherproof cowl as included in DCT2592

All systems include 3 metres of Aluminium Duct


Also includes 900mm of Solid Tube
Also includes 3 metres of Semi-Rigid Duct

THRU- ROOF
Flashing Options

For Iron Roof

Tiled Roof

for the

Laundry

CLASSIC

Dryer Ducting Kits effectively remove the moist warm air generated from clothes dryers and expel it
directly outside. This process eliminates the build up of dampness, helping to keep your home dry and
free from condensation.



Designed for todays modern & classic dryers.


Ducting Kit suits dryers with a 100mm outlet.
The square to round elbow will fit snugly onto
most 100mm dryer outlets.
Easily installed in confined spaces.

INVERTED & WALL MOUNTED DRYER


DUCTING KIT
Duct Size

Model No.

Description

Order Code

100mm

DKSD100

Soffit Ducted

DCT1263

CLASSIC THRU WALL FAN KIT


Duct Size

Model No.

Performance

100mm

XP100S

23l/s, 85m /hr

Order Code

FAN0135

36l/s, 130m /hr

150mm

XP150S

87l/s, 313m /hr

DRYER DUCTING KIT


SOFFIT DUCTED

For soffit ducted free standing


dryers extra rectangular
ducting and a connector will
be required Order Codes:
DCT0013 & DCT0014).

FAN0053
FAN0080

XP125S

PRO SERIES THRU WALL FAN KIT


Duct Size

Model No.

Performance

125mm

XPLP125SS

36l/s, 130m /hr

150mm

XPLP150SS

Order Code

FAN0614

FAN0621

87l/s, 313m /hr

Fully complies to AS/NZS 60335.2.80.


2 Year Warranty.

MANROSE THRU WALL


FAN KITS

125mm

NZS 4303:1990
The New Zealand Building Code
regulations require that any
fan installed in a bathroom,
toilet, laundry or kitchen must
have the exhaust air ducted to
the outside of the home. This
eliminates the build up of an
unhealthy concentration of
moisture in roof cavities.

Thru wall ventilation


kits are ideally suited
to ventilate laundry
areas where utilities
are adjacent to
exterior walls.
Thru wall kit includes
fan, ducting and
grille.
Fully Building Code
compliant
5 Year Warranty

CLASSIC

PRO - SERIES

DUCTING KIT CONTENT


Thru Wall
Rear Vent

Semi Rigid Duct - 400mm length

Thru Wall
Rear/Top

Semi Rigid Duct - 1.5m length

Soffit Kit

Soffit Kit
Galv Tube

Soffit Kit
Semi-Rigid

Thru Roof
125 Iron

Thru Roof
150 Iron

Thru Roof
Tiled

Dryer
Soffit Kit

Semi Rigid Duct - 3m length

Solid Tube - Galvanised 900m length

Flexible Aluminium - 3m length

Flat Channel Ducting - 0.75m length

White Eggcrate Grille

White Gravity Grille

White Fixed Louvre Grille

White Weatherproof Cowl

2 x Rec to Round 90 Elbows

150:125 Reducer

150mm Connector

Thru Roof Cowl

Flashing - Dektite

Flashing - Lead

Duct Tape

COMPONENTS LIST
MANROSE DUCTING

MANROSE CONNECTORS & ADAPTORS

Type

Diameter (mm) Length (m) Order Code

Type

Size (mm)

Order Code

Aluduct Aluminium Flexible

100

DCT0357

Round Adaptor

125

DCT0448

Aluduct Aluminium Flexible

125

DCT0358

Rect : Round Adaptor

335 x 155 : 125

DCT1360

Aluduct Aluminium Flexible

150

DCT0359

Round Connector

100

DCT0159

Semi Rigid

100

1.5

DCT0333

Round Connector

125

DCT0037

Semi Rigid

125

1.5

DCT0334

Round Connector

150

DCT0059

Semi Rigid

150

1.5

DCT0335

Round Reducer

150 : 125

DCT2066

Low Profile Flat Channel

110 x 54

1.5

DCT0013

Round Reducer

150 : 100

DCT2122

Low Profile Flat Channel

204 x 60

1.5

DCT0519

Rectangular Connector

110 x 54

DCT0014

Low Profile Flat Channel

220 x 90

1.5

DCT1443

DCT0124

300 x 25

1.5

DCT1460

Rect : Round Elbow


Connector

110 x 54 : 100

Low Profile Flat Channel


Galvanised Solid Tube

100

0.9

DCT0151

MANROSE WALL/CEILING GRILLES

Galvanised Solid Tube

125

0.9

DCT0152

Type

Size (mm)

Order Code

Galvanised Solid Tube

150

0.9

DCT0153

White Fixed Louvre

100

DCT0025

White Finish PVC Tube

100

0.9

DCT1424

White Fixed Louvre

125

DCT0041

White Finish PVC Tube

125

0.9

DCT1425

White Fixed Louvre

150

DCT0063

White Finish PVC Tube

150

0.9

DCT1426

White Gravity Shutter

100

DCT0029

White Gravity Shutter

125

DCT0044

White Gravity Shutter

All ducting complies with NZ Building Code fire rating requirements.

Round adaptor

Rectangular to round
elbow connector

Round
connector

Fixed louvre
grille

Round to rectangular
connector

Gravity shutter
grille

Round reducer

Weatherproof
cowl

Rectangular
connector

150

DCT0066

White Weatherproof Cowl 100

DCT0018

White Weatherproof Cowl 125

DCT1030

White Weatherproof Cowl 150

DCT1031

Dealers Stamp:

For the full range of


Fans, Ducting,
Grilles and Accessories visit our websites.
www.securimax.co.nz www.manrose.com.au
Securimax reserves the right to alter specifications without notice.

PUB0058
iss12
PUB0058
iss1104/12
05/11

MANROSE RANGEHOOD DUCTING kITS


There are three ducting options available, for the kitchen
rangehood. Through an adjacent wall, through the soffit
(under the eave) or up through the roof.
Semi-Rigid ducting is used in our top of the range systems
to reduce the rangehood system noise and increase air
flow performance.
fully complies to AS/NZS 60335.2.80.

THRu WALL RANgEHOOD DuCTINg KITS


Duct Size (mm)

Description

Order Code

125

Rear Vent - gravity grille

DCT1162

150

Top & Rear Vent Weatherproof Cowl

DCT2592

for added weather protection use the weatherproof cowl


as included in DCT2592.

SOffIT RANgEHOOD DuCTINg KITS


Duct Size (mm)

Description

Order Code

150

Thru Soffit

DCT1161

150

Thru Soffit - galv Tube

DCT1259

150

Thru Soffit - Semi Rigid

DCT2323

All systems include 3 metres of Aluminium Duct.


galv Tube system also includes 900mm of Solid Tube.

THRu ROOf RANgEHOOD DuCTINg KITS


Duct Size (mm)

Description

Order Code

150

Thru Roof - Iron

DCT2324

150

Thru Roof - Tiled

DCT2325

fLASHINg
Iron Roof

161

Tiled Roof

You might also like