Product Information
ZTH EU
Service-Tool for parameterisable and
communicative Belimo actuators /VAV
controllers and HVAC performance
devices.
Connection via service socket on the
device or MP/PP connection.
ZIP-USB function
Technical data
Electrical data
Connection
Interface
Operating modes
Power supply
Operating range
Power consumption Operation
Socket for connecting cable ZK
USB 2.0 Interface
Optional cables
Communication
Parameterization
MP-level converter ( ZIP-Function)
Operating
Safety
Dimensions / Weight
LCD-display
Keys
Protection class
Electromagnetic compatibility
Operating temperature
Non-operating temperature
Dimensions
Weight
AC 24 V, 50/60 Hz, DC 24 V (from actuator)
AC 19,2 ... 28,8 V / DC 21,6 ... 28,8 V
1W
ZK1-GEN (5m) supplied with connector
USB socket Type B, connecting cable (1 m) with
socket A to B supplied
ZK2-GEN, ZK6-GEN
Point to Point (PP), no Bus mode possible (MP)
Point to Point connection
Connection using Service socket on the actuator
or terminals
Connection on the cabinet or over service socket
on the actuator
MP-Monitor operation, connection on the MP-Bus
2 x 16 characters, with background illumination
i / esc / / / OK
III Safety extra-low voltage
CE in accordance with 2004/108/EG
0 50 C, non-condensing
-20 50 C, not-condensing
L x W x D: 95 x 55 x 25 mm
Approx. 135 g
Definitions
ZTH EU
Actuators
www.belimo.com
The ZTH is sold worldwide. Therefore the product name for the European region is defined as
ZTH EU. On the product information, the expression ZTH is representative for the ZTH EU.
For simplicity ,In this documentation the terms actuators, VAV-Controller, fire damper
actuators and HVAC performance devices are summarized by the term actuators.
T9-ZTH EU en v2.0 09.2013 Subject to changes
1 / 20
ZTH EU
Service-Tool for Belimo actuators
Supported devices
Damper product range
Valve product range
EPIV pressure-independent
..-MF / ..-MP / ..-MPL / ..-MFT(2) /..-MOD / ..LON
..-MF / ..-MP / ..-MPL / ..-MFT(2) /..-MOD / ..LON
P6..W..-MP
Available starting 2011
characterised control valve
Fire damper actuator B
VAV product range
HVAC performance devices
sharedlogic
BF-Top Line with BKN230-24MP
VRD2 / VRD2-L
available 1992-2007
VRD3
available starting 2008
VRP-M (VAV- und STP-applications)
available starting 2005
NMV-D2..
available 1992 to 2000
LMV-D2M / NMV-D2M
available 2000 to 2006
LMV-D2-MP / NMV-D2-MP / SMV-D2-MP.., LHV-D2-MP..
available 2006 to 2011
LMV-D2LON / NMV-D2LON
available 2006 to 2011
LMV-D3-MP / NMV-D3-MP / SMV-D3-MP.., LHV-D3-MP..
available starting 2011
LMV-D3LON / NMV-D3LON
available starting 2011
LMV-D3-MOD / NMV-D3-MOD
available starting 2012
According to system description
( e.g. Energy Valve)
According to system description
Safety Notes
2 / 20
The device is not allowed to be used outside the specified field of application,
especially in aircraft or in any other airborne means of transport..
Connection allowed only to Belimo-devices with 24 V- safety extra-low voltage and
PP/MP-interface.
Changes of parameters, etc. may not be performed except after
consultation/specification of the OEM, device or mechanical/electrical contractor.
Operating and adjustment regulations must be observed.
T9-ZTH EU en v2.0 09.2013
www.belimo.com
ZTH EU
Service-Tool for Belimo actuators
Connection ZTH EU
Connection and supply
The ZTH is supplied via the actuator. The connection is set up
directly at the Service socket of the actuator or
via the PP/MP connection (U5) e.g. connection socket, in the control cabinet, room controller
CR24
Types of connection and connection
cables
Suitable cable
ZK1-GEN
Suitable cable
ZK2-GEN
Suitable cable
ZK4-GEN
Suitable cable
ZK6-GEN
Connection in the MP-Bus system
esc
ok
BELIMO
USB
USB
MP
MP
BELIMO
esc
ok
Direct connection to the MP bus or MP master is not possible with the ZTH-GEN.
Solution: Use the service socket on the actuator or temporarily disconnect the MP-connection
of the MP-device from the MP-bus and connect the ZTH-GEN to the MP connection.
www.belimo.com
T9-ZTH EU en v2.0 09.2013 Subject to changes
3 / 20
ZTH EU
Service-Tool for Belimo actuators
Connection ZIP function
Connection via the service socket
Local connection via the service socket cable ZK1-GEN
MP
BELIMO
USB
Belimo
PC-Tool
ZK1-GEN
USB 2.0
esc
ok
24V
GND
2
1
Connection via connection cable
Local connection via ZK2-GEN
~ T
_
ZK2-GEN
MP
BELIMO
USB
Belimo
PC-Tool
AC 24 V
DC 24 V
MP
USB 2.0
esc
GND
ok
weiss / white = GND
Blau / blue = n.angeschlossen /
not connected
Grn / green = MP
~ T
_ +
U5/MP
Antrieb / Actuator
PC-Tool as MP-Master
to parameterize the actuators via MP-Bus
set points for the simulation of actuators via the MP-Bus
reading of the sensors that are connected to the MP-Bus
recording of graphical trends
MP-Master
DDC Controller
UK...Gateway
GND 24 V MP
ZK2-GEN
MP
Verbindung
unterbrechen /
Interupt connection
BELIMO
Belimo
PC-Tool
GND
USB
USB 2.0
esc
MP
ok
weiss / white = GND
Blau / blue = n.angeschlossen /
not connected
Grn / green = MP
Antriebe /
Actuators
(max. 8)
MP-Slave
4 / 20
MP-Slave
T9-ZTH EU en v2.0 09.2013
MP-Slave
MP-Slave
MP-Slave
MP-Slave
www.belimo.com
ZTH EU
Service-Tool for Belimo actuators
Connection ZIP function
PC-Tool connection via ZK6 -GEN,
ZK4-GEN on Belimo gateways
For connection to the UK24MOD and UK24BAC the cable ZK6-GEN can be used
For connection to the UK24EIB and UK24LON the cable ZK4-GEN can be used
MP-Master
UK24MOD / BAC
ZK6-GEN
MP
BELIMO
USB
Belimo
PC-Tool
USB 2.0
esc
ok
MP
Antriebe /
Actuators
(max. 8)
24 V
GND
MP-Slave
www.belimo.com
MP-Slave
MP-Slave
T9-ZTH EU en v2.0 09.2013 Subject to changes
MP-Slave
MP-Slave
MP-Slave
5 / 20
ZTH EU
Service-Tool for Belimo actuators
Connection ZIP-function
PC-Tool as MP-Monitor
Check the MP-communication with the MP-Monitor tool (Module in PC-Tool V3.x)
PC-Tool Monitor connection
ZK2-GEN on MP-Master
MP-Master
DDC Controller
UK...Gateway
GND 24 V MP
ZK2-GEN
MP
BELIMO
Belimo
PC-Tool
GND
esc
USB
USB 2.0
MP
ok
weiss / white = GND
Blau / blue = n.angeschlossen /
not connected
Grn / green = MP
Antriebe /
Actuators
(max. 8)
MP-Slave
MP-Slave
MP-Slave
MP-Slave
MP-Slave
MP-Slave
PC-Tool Monitor connection on tool
socket with ZK6-GEN, ZK4-GEN
MP-Master
UK24MOD / BAC
ZK6-GEN
MP
BELIMO
USB
Belimo
PC-Tool
USB 2.0
esc
ok
MP
Antriebe /
Actuators
(max. 8)
24 V
GND
MP-Slave
6 / 20
T9-ZTH EU en v2.0 09.2013
MP-Slave
MP-Slave
MP-Slave
MP-Slave
MP-Slave
www.belimo.com
ZTH EU
Service-Tool for Belimo actuators
Operating
When connecting the ZTH to the actuator, the control unit will start and read the data from the
connected device.
The available settings and user options are displayed according to the device type.
The available configuration parameters are listed in the product information of all actuators.
See www.belimo.eu
Operating elements
LCD display
MP
- Background illumination
- Display 2 x 16 characters
Key function
USB
and Forward /backward
Value / change Status
OK
Confirm entry, change to
submenu
ESC
Abort entry, leave submenu,
discard changes
i
shows additional information if available
esc
ok
RJ12 Connection socket
USB Connection socket
for PC communication
Language setting, unit depiction
Operating
Menu structure, handling
Language and units can be set in the Configuration menu.
Operating is context-related, i.e. the user sees only the options available for the connected
device.
The corresponding Configuration table is read from the actuator for this purpose. In addition
to the parameter type, this table also contains the corresponding divisions,
e.g.: minimally adjustable running time/type. Non-relevant options are not displayed.
The operating menu can be run through from both sides ( Keys).
Start
Device identification
Typ
Data, settings
Option 1
Option 2
...
Change values
<Parametername>
<Value>
<Parametername>
<Value>
<Parametername>
<Value>
www.belimo.com
OK
OK
esc
Change value (with
<Parametername>
> <Value>
keys)
Press OK to enter the edit mode
(>appears).
Take over new value (with OK)
<Parametername>
Press OK-key to accept the new value
> <Value>
and switch to the main menu.
Discard changes (with ESC)
<Parametername>
Press ESC to cancel the new value and
switch back to main menu.
> <Value>
T9-ZTH EU en v2.0 09.2013 Subject to changes
7 / 20
ZTH EU
Service-Tool for Belimo actuators
Operating
Starting / ending
Device specifications/Technical data
The connection to the actuator is started by plugging in the RJ plug and
terminated by unplugging it.
For a more detailed description, including setting parameters, we draw your attention to the
respective separate product information. See www.belimo.eu Documentation
Configuration
Start configuration
1.
Press the key (OK) while simultaneously plugging in the connecting cable
2.
Configuration menu display appears
Configuration Menu
Option / Display
Setting
Language
Empty cache
German / English
Yes / No
Backlight timeout
After 0..255 sec off
/ always active
disabled/ after
165535 s
Show favourites
Product
range
-
HVAC performance
devices
(Energy Valve)
VAV
VAV
Fire damper
Modbus
OEM-Number
Advanced Mode 1)
065535
Yes / no
Expert Mode 1)
Yes / no
VAV
Valves
PICCV-Function
Yes / no
Valves
Measuring voltage
supply
Pressure unit
Flow unit (Water)
Flow unit (Air)
Exit configuration
Value V (AC)
Pa / inWC
m3/h / l/min / gpm
m3/h / l/s / cfm
ESC
VAV
Valves
VAV
Explanation
Function to delete data
profiles of HVAC
actuators from the local
cache
Setting backlight
duration in seconds
Alternating display of
the first 3 values after
the set time
Enable settings:
VAV: Direction of
rotation
VAV: set Vmin / Vmax
to original values (call
up OEM setting)
BF-Top: Adaption
Modbus: BaseAddress
Enable settings:
VAV: Switching mode
VAV: Vmid parameter
VAV: Altitude
compensation
Valves: Y
characteristic curve
Belimo US
Enable PICCV Wizard
function
Activate option 1) only as needed and with the respective know-how; the adjustment of the
respective parameters requires special expertise.
8 / 20
T9-ZTH EU en v2.0 09.2013
www.belimo.com
ZTH EU
Service-Tool for Belimo actuators
Basic functions
Device identification
The following menu tree shows the basic functions which are identical to all devices.
LM24A-MP
OK
->
esc
Serial number
0082800070140132
* changes according to the type
Typ
LM24A-MP
Firmware
Fw: V01.19
Designation
<designation>
Position
<position>
MP-Address
In MP-capable actuators the MP-Address (PP, MP1-MP8) can be set.
LM24A-MP
->
* changes according to the type
..
MP Adresse:
PP
Modbus actuators
PP, MP1...MP8
(On MF types only PP)
Modbus specific communication settings of an actuator with integrated Modbus interface
(..-MOD).
NMV-D3-MOD
->
....
Expert
Data, Settings
Modbus Address:
1
www.belimo.com
Base Address:
0
Possible settings with
in editing mode:
1...247
0...200
Baudrate
19200
9600 / 19200 / 38400 / 76800 / 115200
Parity
1-8-N-1
1-8-N-2 / 1-8-N-1 / 1-8-E-1 / 1-8-0-1
Termination
off
on / off
T9-ZTH EU en v2.0 09.2013 Subject to changes
9 / 20
ZTH EU
Service-Tool for Belimo actuators
Functions for damper / valve product range
The ZTH recognizes the device family of the connected device automatically
The menu and the settings are shown related to the connected device.
Menu tree
The following menu tree shows the possible settings and values of an LM24A-MP.
LM24A-MP*
->
* changes according to the type
..
Expert
Data, Settings
Min
0%
in editing mode:
0...Max %
Vmid
50%
Vmin...Vmax
Max
90 %
Min...100 %
running time
30 s
depending on type
Mode
2 - 10V
0.5 - 10V/2 - 10V
Act value: 0 %
Set -> OK
10 / 20
Possible settings with
OK
Act value: 0 %
Set OPEN -> /
Range 0...100%
(OPEN/CLOSE/STOP)
PF-Time
10 s
0...10 s (only at Super-CAP actuators)
MP Addresse:
PP
PP, MP1...MP8
(On MF types only PP)
T9-ZTH EU en v2.0 09.2013
www.belimo.com
ZTH EU
Service-Tool for Belimo actuators
Functions for globe valve product range
The ZTH recognizes the device family of the connected device automatically
The menu and the settings are shown related to the connected device.
Menu tree
The following menu tree shows the possible settings and values of an NVK24A-MP-TPC.
NVK24A-MP-TPC*
->
* changes according to the type
....
Expert
Data, Settings
Min
0%
in editing mode:
Min always = 0 %
Vmid
50%
Vmin...Vmax
Min...100 %
running time
90 s
depending on type
Mode
2 - 10V
0.5 - 10V/2 - 10V/0.5 - 10V Y inv/2 - 10V Y inv
Expert
Max
100 %
Y-char
Non- linear
Act value: 0 %
auto
www.belimo.com
Possible settings with
linear/non linear
OK
Act value: 0 %
-> Stop /
Range 0...100%
(OPEN/CLOSE/STOP)
PF-Time
2s
0...10 s (only at Super-CAP actuators)
MP Address:
MP1
PP, MP1...MP8
(On MF types only PP)
T9-ZTH EU en v2.0 09.2013 Subject to changes
11 / 20
ZTH EU
Service-Tool for Belimo actuators
Functions for EPIV pressure-independent
control valve
Menu tree The following menu tree shows the possible settings and values of an EPIV.
SR24A-CF
->
Data, Settings
Volume 0 l/min
Setpoint 0 l/min
Possible settings with
in editing mode:
Volume 0 l/min
Position 65 %
Expert
Volume 0 l/min
Step Auto
12 / 20
Mode
2 - 10V
Auto, OPEN, CLOSE, Max, Stop
0.5 - 10V/2 - 10V/0.5 - 10V Y inv/2 - 10V Y inv
Vmax
331 l/min
0...Vnom
MP Address:
PP
PP, MP1...MP8
(On MF types only PP)
T9-ZTH EU en v2.0 09.2013
www.belimo.com
ZTH EU
Service-Tool for Belimo actuators
Functions for VAV-product range
Menu tree The following menu tree corresponds to the new VAV-Compact D3 generation:
L/N/SMV-D3-MP, LHV-D3-MP, L/ NMV-D3LON , 1) L/MNV-D3-MOD
LMV-D3-MP
->
.
Data, Settings
Volume 125 m3/h
Setpoint 124 m3/h
Possible settings with
in editing mode:
Volume 125 m3/h
DP : 164 Pa
Volume 125 m3/h
Position 65 %
Expert
Mode
2 - 10V
2 - 10V / 0 - 10V
Advanc.
Auto, OPEN, CLOSE, Min, Mid, Max, Stop
Rotation direct.
ccw
ccw / cw
Expert
Volumen 125 m3/h
Step Auto
Set to original
values? No
No / Yes
Expert
Vmin
0m3/h
Vmid
200 m3/h
Vmax
500 m3/h
0...Vmax
Vmin...Vmax
Vmin...Vnom, minimum 20% of Vnom
Advanc.
DP@Vnom
110 Pa
Expert
Vnom
1200 m3/h
Alt.installation
500 m
MP Address:
MP5
Deviations VRD2 (1992-2007)
VRD3 (starting 2008)
VRP-M VAV
NMV-D2 (1992 2000)
NMV-D2M (2000
2006)
Altitude
compensation
Display actual value/setpoint in [% Vnom],
Vmin in [% Vmax], Vmax in [% Vnom]
Display actual value/setpoint in [% Vnom],
Vmin in [% Vnom], Vmax in [% Vnom]
PP, MP1...MP8
(On MF types only PP)
Read only
PP
HW potentiometer setting Tool
Read/write,
otherwise Read only
PP
up to V2.16 Vmin in [% Vmax], Vmax in [%
Vnom]
starting with V3.0 Vmin in [% Vnom], Vmax in
[% Vnom]
Display actual value/setpoint in [% Vnom],
Vmin in [% Vmax], Vmax in [% Vnom
PP / MP18
PP
PP / MP18
This function requires VAV-Compact D3
with firmware V2.06 (03/2013) or higher
and ZTH with firmware V2.01 or higher
Information: VAV-Universal actuators
The V-actuators L/N/SM24A-V, L/NMQ24A-SRV-ST, which fit the VAV universal controllers VR..,
have a tool connection but are nevertheless not tool-capable!
1)
www.belimo.com
0...3000 m
Modbus settings, see previous description of " Basic functions for Modbus actuators"
T9-ZTH EU en v2.0 09.2013 Subject to changes
13 / 20
ZTH EU
Service-Tool for Belimo actuators
Functions for MPL-devices
Menu tree The following menu tree shows the possible settings and values of an MPL-actuator.
MPL-actuator
->
....
Possible settings with
Data, Settings
Act value: 0 %
auto
OK
MP Address:
MP5
Act Value: 0 %
-> Stop /
in editing mode:
Range 0...100%
(OPEN/CLOSE/STOP)
PP, MP1...MP16
Functions for fire dampers
BF-TopLine
Menu tree The following menu tree shows the possible settings and values of a BF-TopLine actuator.
BF24TL-T-ST
->
....
Advanc.
Data, Settings
Range A 95
Adaption No
14 / 20
Possible settings with
Act value: 0 %
Setpoint CLOSE
OPEN, CLOSE
MP Address:
MP4
PP, MP1...MP8
T9-ZTH EU en v2.0 09.2013
in editing mode:
Yes / No
www.belimo.com
ZTH EU
Service-Tool for Belimo actuators
ZIP Functions
In this configuration, the ZTH works as a level converter between the USB port of a PC and the
Belimo MP device
The correct driver will be automatically installed on the PC when plugging the ZTH.
When the USB interface is connected, the ZTH switches to ZIP mode.
Note:
If the ZTH is connected to the PC, the screen flashes a few times until the driver is installed on
the PC.
ZIP Disabled
ZIP disabled
ZIP Master
ZIP Master
Tx:
Rx:
Connection as MP master e.g. PC
If bus communication is present, this is indicated by
flashing of Tx and Rx on the display.
ZIP Monitor
ZIP Monitor
Tx:
Rx:
Connection at monitor function with the PC-Tool
If bus communication is present, this is indicated by
flashing of Tx and Rx on the display.
Checking the power supply
Checking the power supply The ZTH-GEN offers the possibility of checking the AC 24V power supply (III safety extra-low
voltage) of the Belimo devices. Voltages >30V are not permitted!
Application e.g. Commissioning, troubleshooting in the event of a malfunction.
Measurement procedure
Equipment: ZTH, ZK2-GEN
Connection:
connect free wires of the ZK2-GEN to AC 24V.
white on GND (Connection 1 actuator)
blue on ~ (connection 2 actuator)
third wire (turquoise) do not connect
Do not connect RJ12 plug to ZTH-GEN yet!
Start:
End:
Display
Press the ZTH-GEN key (OK) while at the same time connecting the RJ12 plug
Select Supply function with arrow key ()
Disconnect ZTH-GEN RJ12 plug or end Configuration function (ESC)
Supply. okay
AC 25V, VHW: 85%
Quality: okay: AC supply in the division 19.2 ... 28.8V
AC value: measured AC voltage (accuracy 1.0V insofar as VHW >95%)
VHW: Relationship of positive to negative half-wave
The deviation of the positive half-wave value to the value of the negative half-wave
may not be too large. As a rule: positive HW / negative HW x 100 should be >80%.
Explanation VHW
Possible problems
The following items influence the half-wave load:
Transformer too small in its dimensions
long signal cable length from transformer to VAV controller
www.belimo.com
T9-ZTH EU en v2.0 09.2013 Subject to changes
15 / 20
ZTH EU
Service-Tool for Belimo actuators
Firmware Upgrade
The ZTH-EU can be updated using the ZTH updater to the latest firmware version.
The required software and the instructions for the upgrade can be purchased in the download area of the Belimo website www.belimo.eu.
Compatibilities
Function and operation of the new ZTH
The ZTH EU includes the functionality of all previous versions of the ZTH-GEN and ZTH-VAV
The hardware of the ZTH is not compatible with the hardware of the ZTH-GEN. The updates of
the ZTH-GEN cannot be loaded to the ZTH
Actual information to:
Firmware Upgrades
Version overview,
documentation
See www.belimo.eu
In addition, the new ZTH supports the ZIP-USB function. This can be used with for the ZTH EU
updates and as well as level converter USB/MP for the PC-Tool
ZEV
The ZEV Adjuster (1992 to 2007) is replaced by the ZTH.
ZTH-VAV
Is replaced by the new ZTH.
ZTH-GEN V2.xx / V3.xx / V4.xx
Is replaced by the new ZTH.
Version overview
V 2.01 Release of the ZTH and ZIP function
16 / 20
T9-ZTH EU en v2.0 09.2013
www.belimo.com
ZTH EU
www.belimo.com
Service-Tool for Belimo actuators
T9-ZTH EU en v2.0 09.2013 Subject to changes
17 / 20
ZTH EU
18 / 20
Service-Tool for Belimo actuators
T9-ZTH EU en v2.0 09.2013
www.belimo.com
ZTH EU
www.belimo.com
Service-Tool for Belimo actuators
T9-ZTH EU en v2.0 09.2013 Subject to changes
19 / 20
ZTH EU
20 / 20
Service-Tool for Belimo actuators
T9-ZTH EU en v2.0 09.2013
www.belimo.com