Toilet

There are no standard sizes for toilet cubicles, but guidance suggests minimum widths of 800-900mm and depths of at least 1500mm to allow for comfortable entry, movement, and use. Larger cubicles of 1200mm widths and 1500mm depths should be provided for disabled access. Wheelchair accessible cubicles require minimum dimensions of 2200mm depth, 1500mm width, and a 900mm door opening.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
100% found this document useful (1 vote)
7K views1 page

Toilet

There are no standard sizes for toilet cubicles, but guidance suggests minimum widths of 800-900mm and depths of at least 1500mm to allow for comfortable entry, movement, and use. Larger cubicles of 1200mm widths and 1500mm depths should be provided for disabled access. Wheelchair accessible cubicles require minimum dimensions of 2200mm depth, 1500mm width, and a 900mm door opening.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

What are a Standard Toilet Cubicle Dimensions?

There are no set standard sizes and dimensions for toilet cubicles, only minimum measurements to
allow for user comfort. If a cubicle is too small people will struggle to comfortably enter, manoeuvre
and seat themselves, particularly while carrying baggage and other personal items. Particular care
should be given to cubicle door sizes, allowing sufficient space for a door to swing open and miss the
toilet pan.
By way of guidance we suggest allowing at least 800-900mm widths and depths of at least 1500mm
from front to back. This should allow for a 450mm manoeuvring space within the cubicle. Please see
diagram below:

Where a washroom has 4 or more toilet cubicles there is a requirement that one of these should be
configured as an enlarged cubicle, which includes an outward opening door and grab rails. The
suggested sizes of an enlarged cubicle are 1200mm width and 1500mm depth.
If a wheelchair accessible toilet cubicle is provided it should meet the following minimum dimensions
under Document M of the Building Regulations:

Depth 2200mm
Width 1500mm
Door Opening 900mm