DATA SHEET
AST
HPL 50-1/4 XF
M5361T
Flame retardant Low Smoke Zero Halogen
Page: 1/1
1 Inner conductor : Copper-clad Aluminium
Diameter : 1.75 0.05 mm
2 - Dielectric : Physically foam polyethylene
Diameter : 4.80 0.10 mm
3 Outer Conductor : Alu/Polyester/Alu tape
Tinned copper braid, wire diameter : 0.15 mm - Coverage > 40%
Diameter over braid : 5.60 mm
4 - Jacket : Black Fire Retardant Low Smoke Halogen compound
Diameter : 6.85 0.15 mm
5 - Ink marking : Metric length
ACOME HYPERCELL COAX LSOH HPL 50-1/4XF M5361 LOT Nlot
Mechanical characteristics
Packaging : 1000 meters (PW 70)
Minimum Bending radius (Multiple bending) : 20 mm
Weight : 57 kg/km
Fire resistance : IEC 332-1
Installation / operating Tensile Strength : 600 / 400 N
Smoke toxicity : IEC 754-2 / NFC 20-454
Installation temperature range : -20C / + 60C
Smoke density : IEC 1034
Operating temperature range : -40C/ + 85C
Electrical characteristics
Operating frequency : 15 GHz
Impedance : 50 1.5
Peak power rating : 3.6 kW
Capacitance : 79 pF/m, typical value
Operating voltage : 0.6 kV RMS
Velocity : 84% , dielectric constant : 1.42 (typical value)
Return Loss (jumper L=1m) :
maxi -26.5 dB from 806 to 960 MHz
maxi -24 dB from 1700 to 2200 MHz
Test voltage : 1.2 kV RMS
Insulation resistance : > 10000 M.km
DC resistance :
Inner conductor : < 11 /km
Outer conductor : < 10.50 /km
maxi -23.5 dB from 2500 to 2700 MHz
Screnning effectiveness : > 85 dB - from 5 MHz to 1000 MHz
Frequency MHz
Arttenuation dB/100 m
Power (kW) 40C ambient temperature,
Inner conductor + 100C
10
2.74
30
4.32
100
6.94
300
11.47
450
14.29
900
20.9
1000
21.83
1500
27.13
1800
29.60
2000
31.59
3000
39.40
3.00
1.84
1.09
0.67
0.56
0.41
0.38
0.31
0.28
0.26
0.22
100
A tte n u a tio n d B /1 0 0 m
Attenuation dB/100 m -Power KW
Po w e r
10
0 .1
10
Written by : LSC
100
Fr e q u e n c y M Hz
Approved by : LYB
1000
10000
Edition : B1 - 23 / 07 / 2006
DIVISION TELECOMMUNICATION - 52, rue du Montparnasse - 75014 PARIS - France Tl : +(33) 1 42 79 14 00 - Fax (33) 1 42 79 15 00 E-Mail : DTLC@acome.fr