0% found this document useful (0 votes)
434 views1 page

Telecom Cable Specifications

This document provides specifications for an AST HPL 50-1/4 XF flame retardant low smoke zero halogen coaxial cable. The cable has a copper-clad aluminum inner conductor, polyethylene dielectric, aluminum/polyester/aluminum outer conductor with 40% coverage copper braid, and a black fire retardant low smoke halogen jacket. Key specifications include an operating frequency up to 15 GHz, impedance of 50±1.5 ohms, capacitance of 79 pF/m, velocity of 84%, and attenuation ranging from 2.74 to 39.4 dB/100m from 10 to 3000 MHz.

Uploaded by

gakin2
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
434 views1 page

Telecom Cable Specifications

This document provides specifications for an AST HPL 50-1/4 XF flame retardant low smoke zero halogen coaxial cable. The cable has a copper-clad aluminum inner conductor, polyethylene dielectric, aluminum/polyester/aluminum outer conductor with 40% coverage copper braid, and a black fire retardant low smoke halogen jacket. Key specifications include an operating frequency up to 15 GHz, impedance of 50±1.5 ohms, capacitance of 79 pF/m, velocity of 84%, and attenuation ranging from 2.74 to 39.4 dB/100m from 10 to 3000 MHz.

Uploaded by

gakin2
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

DATA SHEET

AST

HPL 50-1/4 XF

M5361T

Flame retardant Low Smoke Zero Halogen

Page: 1/1

1 Inner conductor : Copper-clad Aluminium


Diameter : 1.75 0.05 mm
2 - Dielectric : Physically foam polyethylene
Diameter : 4.80 0.10 mm
3 Outer Conductor : Alu/Polyester/Alu tape
Tinned copper braid, wire diameter : 0.15 mm - Coverage > 40%
Diameter over braid : 5.60 mm
4 - Jacket : Black Fire Retardant Low Smoke Halogen compound
Diameter : 6.85 0.15 mm
5 - Ink marking : Metric length

ACOME HYPERCELL COAX LSOH HPL 50-1/4XF M5361 LOT Nlot


Mechanical characteristics
Packaging : 1000 meters (PW 70)

Minimum Bending radius (Multiple bending) : 20 mm

Weight : 57 kg/km
Fire resistance : IEC 332-1

Installation / operating Tensile Strength : 600 / 400 N

Smoke toxicity : IEC 754-2 / NFC 20-454

Installation temperature range : -20C / + 60C

Smoke density : IEC 1034

Operating temperature range : -40C/ + 85C

Electrical characteristics

Operating frequency : 15 GHz

Impedance : 50 1.5

Peak power rating : 3.6 kW

Capacitance : 79 pF/m, typical value

Operating voltage : 0.6 kV RMS

Velocity : 84% , dielectric constant : 1.42 (typical value)


Return Loss (jumper L=1m) :
maxi -26.5 dB from 806 to 960 MHz
maxi -24 dB from 1700 to 2200 MHz

Test voltage : 1.2 kV RMS


Insulation resistance : > 10000 M.km
DC resistance :

Inner conductor : < 11 /km


Outer conductor : < 10.50 /km

maxi -23.5 dB from 2500 to 2700 MHz


Screnning effectiveness : > 85 dB - from 5 MHz to 1000 MHz
Frequency MHz
Arttenuation dB/100 m
Power (kW) 40C ambient temperature,
Inner conductor + 100C

10
2.74

30
4.32

100
6.94

300
11.47

450
14.29

900
20.9

1000
21.83

1500
27.13

1800
29.60

2000
31.59

3000
39.40

3.00

1.84

1.09

0.67

0.56

0.41

0.38

0.31

0.28

0.26

0.22

100

A tte n u a tio n d B /1 0 0 m
Attenuation dB/100 m -Power KW

Po w e r

10

0 .1
10

Written by : LSC

100

Fr e q u e n c y M Hz

Approved by : LYB

1000

10000

Edition : B1 - 23 / 07 / 2006

DIVISION TELECOMMUNICATION - 52, rue du Montparnasse - 75014 PARIS - France Tl : +(33) 1 42 79 14 00 - Fax (33) 1 42 79 15 00 E-Mail : DTLC@acome.fr