0% found this document useful (0 votes)
83 views17 pages

Tenis: Outdoor

The document provides a summary of lighting calculations for an outdoor tennis court. It includes 8 luminaires of type HNF003, with a total installed power of 3.45 kW. Calculation results show an average surface illuminance of 391 lux for the general area and 439 lux for the tennis court area. Minimum and maximum values are also reported. Tables, graphs and diagrams are provided to show the illuminance levels across the illuminated area.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
83 views17 pages

Tenis: Outdoor

The document provides a summary of lighting calculations for an outdoor tennis court. It includes 8 luminaires of type HNF003, with a total installed power of 3.45 kW. Calculation results show an average surface illuminance of 391 lux for the general area and 439 lux for the tennis court area. Minimum and maximum values are also reported. Tables, graphs and diagrams are provided to show the illuminance levels across the illuminated area.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 17

TENIS

OUTDOOR
Date: 19-12-2016
Customer: Dr.Syamsuarnis

Designer: AIDIL SYAPUTRA (15063026)

The nominal values shown in this report are the result of precision calculations, based upon precisely positioned luminaires in a fixed relationship
to each other and to the area under examination. In practice the values may vary due to tolerances on luminaires, luminaire positioning,
reflection properties and electrical supply.

PENDIDIKAN TEKNIK ELEKTRO


FAKULTAS TEKNIK
UNIVERSITAS NEGERI PADANG

CalcuLuX Area 5.0b


TENIS PENDIDIKAN TEKNIK ELEKTRO
OUTDOOR Date: 19-12-2016

Table of Contents

1. Project Description 3

1.1 3-D Project Overview 3

2. Summary 4

2.1 General Information 4


2.2 Project Luminaires 4
2.3 Calculation Results 4

3. Calculation Results 5

3.1 General: Textual Table 5


3.2 General: Graphical Table 7
3.3 General: Iso Contour 8
3.4 General: Filled Iso Contour 9
3.5 General: Mountain Plot 10
3.6 Tennis: Textual Table 11
3.7 Tennis: Graphical Table 12
3.8 Tennis: Iso Contour 13
3.9 Tennis: Filled Iso Contour 14
3.10 Tennis: Mountain Plot 15

4. Luminaire Details 16

4.1 Project Luminaires 16

5. Installation Data 17

5.1 Legends 17
5.2 Luminaire Positioning and Orientation 17

CalcuLuX Area 5.0b Philips Lighting B.V. Page: 2/17


TENIS PENDIDIKAN TEKNIK ELEKTRO
OUTDOOR Date: 19-12-2016

1. Project Description

1.1 3-D Project Overview

A A

A A

Z Y

A HNF003

CalcuLuX Area 5.0b Philips Lighting B.V. Page: 3/17


TENIS PENDIDIKAN TEKNIK ELEKTRO
OUTDOOR Date: 19-12-2016

2. Summary

2.1 General Information

The overall maintenance factor used for this project is 1.00.

2.2 Project Luminaires

Code Qty Luminaire Type Lamp Type Power (W) Flux (lm)
A 8 HNF003 1 * SON-T400W 431.0 1 * 48000

The total installed power: 3.45 (kWatt)

Number of Luminaires Per Arrangement:


Luminaire
Arrangement Code Power (kWatt)
A
Polar 2 0.86
Polar2 2 0.86
Polar3 2 0.86
Polar4 2 0.86

2.3 Calculation Results

(Il)luminance Calculations:
Calculation Type Unit Ave Min/Ave Min/Max
General Surface Illuminance lux 391 0.20 0.11
Tennis Surface Illuminance lux 439 0.44 0.26

CalcuLuX Area 5.0b Philips Lighting B.V. Page: 4/17


TENIS PENDIDIKAN TEKNIK ELEKTRO
OUTDOOR Date: 19-12-2016

3. Calculation Results

3.1 General: Textual Table

Grid : General at Z = 0.00 m


Calculation : Surface Illuminance (lux)

X (m) -7.00 -6.00 -5.00 -4.00 -3.00 -2.00 -1.00 0.00 1.00 2.00 3.00 4.00 5.00
Y (m)
15.00 79 106 157 231 301 281 224 199 225 283 299 229 156
14.00 99 137 179 257 353 347 279 248 281 348 351 255 178
13.00 133 166 206 290 411 421 348 303 350 422 408 288 206
12.00 172 192 238 323 465 502 421 364 423 503 462 321 237
11.00 199 220 269 355 511 590 500 436 502 590 506 352 268
10.00 223 253 295 378 533 657 569 504 571 657 528 375 294
9.00 236 272 311 381 517 657 609 550 610 654 512 379 310
8.00 247 281 326 391 503 630 626 591 627 627 500 390 325
7.00 251 290 342 408 493 607 636 626 636 605 491 407 341
6.00 248 292 348 417 491 599 650 656 649 596 489 417 347
5.00 238 283 345 421 500 599 675 698 675 596 499 421 345
4.00 224 271 335 419 513 617 714 734 712 616 512 419 335
3.00 209 256 319 403 511 615 706 736> 703 613 511 403 319
2.00 198 242 303 384 489 599 693 736 692 597 489 383 303
1.00 191 231 289 370 466 574 679 726 678 574 466 370 289
0.00 188 226 284 364 458 562 675 726 676 562 458 364 284
-1.00 191 231 289 369 465 572 677 726 679 574 466 370 289
-2.00 198 242 303 383 487 595 689 735 693 598 489 384 303
-3.00 209 256 318 403 509 610 701 735 705 614 511 404 319
-4.00 224 271 334 419 511 613 710 734 713 617 514 420 335
-5.00 238 283 345 421 498 595 675 699 676 597 500 422 345
-6.00 248 292 348 417 489 595 648 657 650 596 490 418 348
-7.00 251 290 342 407 491 605 635 626 636 605 491 407 342
-8.00 247 282 327 392 504 627 624 589 627 627 501 390 326
-9.00 236 272 313 383 518 656 606 547 609 655 513 380 311
-10.00 223 254 298 382 541 657 564 501 571 657 528 375 295
-11.00 200 222 272 361 519 591 497 433 501 590 506 353 268
-12.00 174 194 242 331 473 503 418 361 422 503 462 321 237
-13.00 134 169 211 299 419 420 343 301 348 421 408 288 206
-14.00 101 140 184 266 359 344 276 246 280 348 351 255 178
-15.00 80 109 162 241 305 277 219 197 224 282 299 229 156
Continue >

Average Min/Ave Min/Max Project maintenance factor


391 0.20 0.11 1.00

CalcuLuX Area 5.0b Philips Lighting B.V. Page: 5/17


TENIS PENDIDIKAN TEKNIK ELEKTRO
OUTDOOR Date: 19-12-2016

< Continue

Grid : General at Z = 0.00 m


Calculation : Surface Illuminance (lux)

X (m) 6.00 7.00


Y (m)
15.00 105 79<
14.00 137 99
13.00 165 133
12.00 191 172
11.00 220 199
10.00 254 223
9.00 272 236
8.00 281 247
7.00 290 251
6.00 291 248
5.00 283 238
4.00 271 223
3.00 256 209
2.00 242 198
1.00 231 191
0.00 226 188
-1.00 231 191
-2.00 243 198
-3.00 256 209
-4.00 271 223
-5.00 283 238
-6.00 292 248
-7.00 290 251
-8.00 282 247
-9.00 272 236
-10.00 254 223
-11.00 221 200
-12.00 192 173
-13.00 166 133
-14.00 137 100
-15.00 105 79

Average Min/Ave Min/Max Project maintenance factor


391 0.20 0.11 1.00

CalcuLuX Area 5.0b Philips Lighting B.V. Page: 6/17


TENIS PENDIDIKAN TEKNIK ELEKTRO
OUTDOOR Date: 19-12-2016

3.2 General: Graphical Table

Grid : General at Z = 0.00 m


Calculation : Surface Illuminance (lux)
17

79 106 157 231 301 281 224 199 225 283 299 229 156 105 79
99 137 179 257 353 347 279 248 281 348 351 255 178 137 99
133 166 206 290 411 421 348 303 350 422 408 288 206 165 133
172 192 238 323 465 502 421 364 423 503 462 321 237 191 172
12

199 220 269 355 511 590 500 436 502 590 506 352 268 220 199
223 253 295 378 533 657 569 504 571 657 528 375 294 254 223
236 272 311 381 517 657 609 550 610 654 512 379 310 272 236
A A
247 281 326 391 503 630 626 591 627 627 500 390 325 281 247
251 290 342 408 493 607 636 626 636 605 491 407 341 290 251
7

248 292 348 417 491 599 650 656 649 596 489 417 347 291 248
238 283 345 421 500 599 675 698 675 596 499 421 345 283 238
224 271 335 419 513 617 714 734 712 616 512 419 335 271 223
209 256 319 403 511 615 706 736 703 613 511 403 319 256 209
198 242 303 384 489 599 693 736 692 597 489 383 303 242 198
2

191 231 289 370 466 574 679 726 678 574 466 370 289 231 191
188 226 284 364 458 562 675 726 676 562 458 364 284 226 188
Y(m)

191 231 289 369 465 572 677 726 679 574 466 370 289 231 191
198 242 303 383 487 595 689 735 693 598 489 384 303 243 198
209 256 318 403 509 610 701 735 705 614 511 404 319 256 209
-3

224 271 334 419 511 613 710 734 713 617 514 420 335 271 223
238 283 345 421 498 595 675 699 676 597 500 422 345 283 238
248 292 348 417 489 595 648 657 650 596 490 418 348 292 248
251 290 342 407 491 605 635 626 636 605 491 407 342 290 251
247 282 327 392 504 627 624 589 627 627 501 390 326 282 247
-8

236 272 313 383 518 656 606 547 609 655 513 380 311 272 236
A A
223 254 298 382 541 657 564 501 571 657 528 375 295 254 223
200 222 272 361 519 591 497 433 501 590 506 353 268 221 200
174 194 242 331 473 503 418 361 422 503 462 321 237 192 173
134 169 211 299 419 420 343 301 348 421 408 288 206 166 133
-13

101 140 184 266 359 344 276 246 280 348 351 255 178 137 100
80 109 162 241 305 277 219 197 224 282 299 229 156 105 79
-18

-18 -13 -8 -3 2 7 12 17
X(m)

A HNF003

Average Min/Ave Min/Max Project maintenance factor Scale


391 0.20 0.11 1.00 1:200

CalcuLuX Area 5.0b Philips Lighting B.V. Page: 7/17


TENIS PENDIDIKAN TEKNIK ELEKTRO
OUTDOOR Date: 19-12-2016

3.3 General: Iso Contour

Grid : General at Z = 0.00 m


Calculation : Surface Illuminance (lux)
17

0
10

10
0 0
30

0
20

20
12

0
500
400
A A

60
0
300
7

400
2

500
2 00
Y(m)

200
700

300
-3

600
600
-8

500

A A
400
300
20

40
0

0
-13

20
0

10
0 0
0

30
10

200
-18

-18 -13 -8 -3 2 7 12 17
X(m)

A HNF003

Average Min/Ave Min/Max Project maintenance factor Scale


391 0.20 0.11 1.00 1:200

CalcuLuX Area 5.0b Philips Lighting B.V. Page: 8/17


TENIS PENDIDIKAN TEKNIK ELEKTRO
OUTDOOR Date: 19-12-2016

3.4 General: Filled Iso Contour

Grid : General at Z = 0.00 m


Calculation : Surface Illuminance (lux)
17
12

700

A A
7

600

500
2
Y(m)

400
-3

300
-8

A A
200
-13

100
-18

-12 -7 -2 3 8 13
X(m)

A HNF003

Average Min/Ave Min/Max Project maintenance factor Scale


391 0.20 0.11 1.00 1:200

CalcuLuX Area 5.0b Philips Lighting B.V. Page: 9/17


TENIS PENDIDIKAN TEKNIK ELEKTRO
OUTDOOR Date: 19-12-2016

3.5 General: Mountain Plot

Grid : General at Z = 0.00 m


Calculation : Surface Illuminance (lux)

15

10

5
-10
0
)
-5
Y(m
-5
0
X(m
) -10
5
-15
10

Average Min/Ave Min/Max Project maintenance factor


391 0.20 0.11 1.00

CalcuLuX Area 5.0b Philips Lighting B.V. Page: 10/17


TENIS PENDIDIKAN TEKNIK ELEKTRO
OUTDOOR Date: 19-12-2016

3.6 Tennis: Textual Table

Grid : Tennis at Z = 0.00 m


Calculation : Surface Illuminance (lux)

X (m) -6.00 -4.00 -2.00 0.00 2.00 4.00 6.00


Y (m)
12.00 192 323 502 364 503 321 191<
10.00 253 378 657 504 657 375 254
8.00 281 391 630 591 627 390 281
6.00 292 417 599 656 596 417 291
4.00 271 419 617 734 616 419 271
2.00 242 384 599 736> 597 383 242
0.00 226 364 562 726 562 364 226
-2.00 242 383 595 735 598 384 243
-4.00 271 419 613 734 617 420 271
-6.00 292 417 595 657 596 418 292
-8.00 282 392 627 589 627 390 282
-10.00 254 382 657 501 657 375 254
-12.00 194 331 503 361 503 321 192

Average Min/Ave Min/Max Project maintenance factor


439 0.44 0.26 1.00

CalcuLuX Area 5.0b Philips Lighting B.V. Page: 11/17


TENIS PENDIDIKAN TEKNIK ELEKTRO
OUTDOOR Date: 19-12-2016

3.7 Tennis: Graphical Table

Grid : Tennis at Z = 0.00 m


Calculation : Surface Illuminance (lux)
17

192 323 502 364 503 321 191


12

253 378 657 504 657 375 254

A A
281 391 630 591 627 390 281
7

292 417 599 656 596 417 291

271 419 617 734 616 419 271

242 384 599 736 597 383 242


2

226 364 562 726 562 364 226


Y(m)

242 383 595 735 598 384 243


-3

271 419 613 734 617 420 271

292 417 595 657 596 418 292

282 392 627 589 627 390 282


-8

A A
254 382 657 501 657 375 254

194 331 503 361 503 321 192


-13
-18

-18 -13 -8 -3 2 7 12 17
X(m)

A HNF003

Average Min/Ave Min/Max Project maintenance factor Scale


439 0.44 0.26 1.00 1:200

CalcuLuX Area 5.0b Philips Lighting B.V. Page: 12/17


TENIS PENDIDIKAN TEKNIK ELEKTRO
OUTDOOR Date: 19-12-2016

3.8 Tennis: Iso Contour

Grid : Tennis at Z = 0.00 m


Calculation : Surface Illuminance (lux)
17
12

500
300

600

300
A A
7

4 00
700
2

300

600
Y(m)

300
500
500
-3

600
400
-8

0
60
3 00

A A
300
-13
-18

-18 -13 -8 -3 2 7 12 17
X(m)

A HNF003

Average Min/Ave Min/Max Project maintenance factor Scale


439 0.44 0.26 1.00 1:200

CalcuLuX Area 5.0b Philips Lighting B.V. Page: 13/17


TENIS PENDIDIKAN TEKNIK ELEKTRO
OUTDOOR Date: 19-12-2016

3.9 Tennis: Filled Iso Contour

Grid : Tennis at Z = 0.00 m


Calculation : Surface Illuminance (lux)
17
12

A A 700
7

600
2
Y(m)

500
-3

400
-8

A A

300
-13
-18

-12 -7 -2 3 8 13
X(m)

A HNF003

Average Min/Ave Min/Max Project maintenance factor Scale


439 0.44 0.26 1.00 1:200

CalcuLuX Area 5.0b Philips Lighting B.V. Page: 14/17


TENIS PENDIDIKAN TEKNIK ELEKTRO
OUTDOOR Date: 19-12-2016

3.10 Tennis: Mountain Plot

Grid : Tennis at Z = 0.00 m


Calculation : Surface Illuminance (lux)

12
10
8
6
4
2
-6 0
m )
-4 -2 Y(
-2 -4
X(m0 -6
) 2 -8
4 -10
6 -12

Average Min/Ave Min/Max Project maintenance factor


439 0.44 0.26 1.00

CalcuLuX Area 5.0b Philips Lighting B.V. Page: 15/17


TENIS PENDIDIKAN TEKNIK ELEKTRO
OUTDOOR Date: 19-12-2016

4. Luminaire Details

4.1 Project Luminaires

HNF003 1xSON-T400W Luminous Intensity Diagram (candela/1000 lumen)


120o 150o 180o 150o 120o
Light output ratios
DLOR : 0.72
ULOR : 0.00
TLOR : 0.72
Ballast : Standard 90o 90o
Lamp flux : 48000 lm
Luminaire wattage : 431.0 W
Measurement code : LVT0653600
60o 60o

1500

30o 0o 30o
C = 180 o C = 0o
C = 270 o Imax C = 90o

CalcuLuX Area 5.0b Philips Lighting B.V. Page: 16/17


TENIS PENDIDIKAN TEKNIK ELEKTRO
OUTDOOR Date: 19-12-2016

5. Installation Data

5.1 Legends

Project Luminaires:
Code Qty Luminaire Type Lamp Type Flux (lm)
A 8 HNF003 1 * SON-T400W 1 * 48000

5.2 Luminaire Positioning and Orientation

Qty and Position Aiming Angles


Code
X (m) Y (m) Z (m) Rot. Tilt90 Tilt0
1 *A -7.50 -9.00 12.00 -10.90 24.80 0.00
1 *A -7.50 -9.00 12.00 29.60 45.20 0.00
1 *A -7.50 9.00 12.00 10.20 24.90 0.00
1 *A -7.50 9.00 12.00 -29.70 45.20 0.00
1 *A 7.50 -9.00 12.00 -169.80 25.00 0.00

1 *A 7.50 -9.00 12.00 150.30 45.20 0.00


1 *A 7.50 9.00 12.00 169.80 25.00 0.00
1 *A 7.50 9.00 12.00 -150.20 45.20 0.00

CalcuLuX Area 5.0b Philips Lighting B.V. Page: 17/17