0% found this document useful (0 votes)
2K views2 pages

Vitros 3600 Immunodiagnostic System Specifications Sheet: Shapes The Art of Living

The document provides specifications for the VITROS 3600 Immunodiagnostic System. It analyzes samples on microplates and provides results within 16-73 minutes. It can run up to 3,100 assays from samples like serum, plasma and urine. The system has reagent packs, onboard storage, and interfaces with laboratory information systems.

Uploaded by

Noval Farlan
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
2K views2 pages

Vitros 3600 Immunodiagnostic System Specifications Sheet: Shapes The Art of Living

The document provides specifications for the VITROS 3600 Immunodiagnostic System. It analyzes samples on microplates and provides results within 16-73 minutes. It can run up to 3,100 assays from samples like serum, plasma and urine. The system has reagent packs, onboard storage, and interfaces with laboratory information systems.

Uploaded by

Noval Farlan
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

VITROS 3600 Immunodiagnostic System1

Specifications Sheet

Measurement Principle: Time for Single Result:


+ Enhanced Chemiluminescence using MicroWell + MicroWell: ~16-73 minutes
technology + Real-time results data stream to LIS available
Sample Types:
Reagents: + Serum, Plasma, Urine, Whole Blood,**
+ No preparation, no mixing or reconstitution required Amniotic Fluid***
for Integrated Reagent Packs, Signal Reagent and
Universal Wash Reagent Sample Volume:
+ Onboard stability up to 84 days + Per assay: 10-80L
+ Shelf life stability up to 12 months from date of + Dead volume: minimum 35L
manufacture
+ Onboard test capacity: Sample Capacity:
Up to 3,100 assays + Continuous load and unload
31 reagent positions + 80 samples in Universal Sample Trays
100* assays per pack + 10 samples in dedicated STAT lane

Consumables: Sample and Reagent Management Incorporating


+ VersaTips, Signal Reagent and Universal Wash Intellicheck Technology:
Reagent can be replenished without interrupting + Single-use Tip Metering verifies sample aspiration
system operation. Reagents replenished without and dispense, eliminates carryover and addresses
interrupting incubation cross-contamination concerns
+ Onboard capacity and typical replenish frequency: + Clot, bubble, low and high viscosity, thin layer fluid
VersaTips: 2000 24 hours and short sample detection
Signal Reagent: 3 packs 48 hours + Save-the-Sample Clot/Bubble Management
Universal Wash Reagent: 5 liters 72 hours + Liquid level sensing
+ MicroWell Dispense Verification
Calibration: + Reagent aspiration and dispense verifications
+ 25 lots per assay may be calibrated with automatic lot + Onboard IntelliReport provides complete traceability
switching and documentation of result quality
+ Stable for up to 28 days
+ Random-access calibration Sample Containers:
+ Bar-coded calibrators + Universal Sample Trays accommodate:
5mL, 7mL, 10mL collection tubes
System Startup: 1.5mL micro-collection containers
+ 2 4-hour ready mode VITROS microsample cups and 0.5mL and
+ No manual primes, purges, washes or tubing 2.0mLcups
maintenance
+ No daily calibrations or calibration checks
+ Automatic integrated prime/purge

1
Availability is subject to local regulatory requirements
* HBc IgM and HAV IgM have 52 tests per pack.
** For Red Cell Folate
The science of knowing shapes the art of living. *** Not commercially available in the United States
Sample Bar Code Identification: Power:
+ Autodiscriminates by simultaneously recognizing + L ine Voltage: 1 dedicated 20 amp power line, or 1
all standard symbologies: dedicated 30 amp power line with UPS, nominal
Code 128 200-240V AC
ISBT 128 + Line Frequency: 47-63 Hz
Code 39
Codabar Environment:
Interleaved 2 of 5 + Operating Temperature: 15-30C/59-86F
+ Ambient Relative Humidity: 15%-75% RH
Dilution Capabilities: non-condensing
+ Auto reflex dilution + Altitude: up to 2,438 m/8,000 feet
+ Operator requested dilution + Plumbing: No water or drain required; self-
+ Off-board dilution calculation contained onboard waste management eliminates
special requirements for off-board plumbing
Automatic Reflex Testing (based on user-configuration):
+ Reflex to different assays Communications:
+ Reflex to the same assay + Laboratory Information System (LIS):
Bidirectional interface for ASTM and HL7
Operator Interface: protocols
+ Color-coded graphical user interface Broadcast download and Host Query
+ Ergonomic flat, low-glare, LCD, 17-inch touchscreen Results can be uploaded individually or as an
monitor entire sample
+ Numeric keypad on monitor + Laboratory Automation System (LAS):
+ Detached keyboard for maximum flexibility AT ready at launch
+ Onboard documentation and animated Help (V-Docs) 1 LAS interface, point-in-space
+ Onboard maintenance documentation + Ports:
RS 232 serial ports (for LIS and LAS)
Data Storage: USB ports (for printers)
+ Read/write disk drive for data input and archiving Ethernet ports (for e-Connectivity)
+ USB flash drive (memory stick) capabilities
+ 5,000 sample programs e-Connectivity Interactive System Management:
+ 25,000 samples with ability to archive and retrieve + Using the facilitys Internet connection or DSL,
through CD-ROM or memory stick VPN establishes a secure connection between
system and Ortho Clinical Diagnostics Technical
System Dimensions: Support to enhance troubleshooting and increase
+ Width: 2.12 m/83.5 inches uptime
+ Depth: 0.85 m/33.5 inches + Automatic two-way data exchange to
+ Height: 1.64 m/64.5 inches automatically send and retrieve data
+ Weight: 717 kg/1580 pounds + Automatic download of system software updates
+ Remote connectivity provides the ability to
enable remote diagnostics and remote control
operation
+ Enhance uptime with predictive alerts

The science of knowing shapes the art of living. www.orthoclinical.com | All trademarks are the property of Ortho-Clinical Diagnostics, Inc. Ortho-Clinical Diagnostics, Inc. 2009 CL10882 January 2009