LIST OF CONTENTS
      2.       General                                                   8.      Lubrication
                                                                         8.1     General
      3.       Notes on transportation                                   8.2     Qil lubrication qualities
                                                                         8.3     Oil filling - transparent reservoir
      4.       Storage                                                   8.4     Oil fillings
                                                                         8.5     Oil change
      5.       Installation
      5.1      Preparation                                               9.      Blower - cleaning
      5.2      Type of foundation
      5.3      Preparing the foundation                                  10.     Change of flow direction
      5.4      Alignment
      5.5      Anchoring bolts                                           11.     Watercooled seal ring housing
      5.6      Coupling and pulleys
      5.7      V-belts                                                   12.     Spare parts list
      5.8      Final adjustment
      5.9      Pipelines                                                 13.     Mechanical load limits of the
                                                                                 Rough Vacuum blowers
      6.       Initial start-up                                          13.1    Direct coupled speeds
      6.1      Test run of drive motor                                   13.2    V-belt-drive
      6.2      Test run of blower
4PG-401EN page 2 of 14
0368-002
  Aerzener Maschinenfabrik GmbH
  Reherweg 28 / D-31855 Aerzen, Postfach 11 63 / D-31849 Aerzen, Tel.: 05154/810, Fax: 05154/81191
      1.     Safety information
      1.1     General
      The Positive Displacement Blowers are constructed according to the latest technical standards;
      the requirements of the German regulations for accident prevention VBG 16 are fulfilled.
      Nevertheless, operating risks resulting from improper handling, inappropriate use or operation by untrained
      personnel cannot be excluded.
      These may result in injuries, as well as damage to the machines and production work.
      In the users plant, anyone involved in the operation, maintenance and repair of the machines must have read and
      understood the operating/maintenance manual, and in particular this safety information.
      The machines must only be handled and operated by trained and authorized personnel.
      Responsibility for the operation of the machines must be clearly defined in order to avoid uncertainties of
      competence.
      All work performed on the machines, including repairs, oil changes, maintenance etc. are to be carried out during
      machine shutdown, with the electrical power supply to the compressor shut-off and locked out.
4PG-401EN page 3 of 14
0368-002
  Aerzener Maschinenfabrik GmbH
  Reherweg 28 / D-31855 Aerzen, Postfach 11 63 / D-31849 Aerzen, Tel.: 05154/810, Fax: 05154/81191
      2.     General
             These rotary piston blowers (Roots principle), used in vacuum operation, are distinguished by the
             letter "G". The subsequent letters "L" or "M" indicate the direction of flow.
             The numbers, e.g. "14.9", indicate the model size. The letters "HV" following mean "high vacuum"
             and the letter "m" following means "with auxiliary inlet".
                                                                                        coolant channel
                                                                                        water cooling at blower size
                                                                                        18.17 and above.
             The radial sealing rings run on a hardened and ground shaft protection sleeve. The oil chamber
             ensures that the radial sealing rings are vacuum-tight and have a long service life.
             The level of sealing oil can be checked visually through the transparent oil tank. Oil must be always
             be present. (see: Lubrication)
             Concerning the blower types HV 18.17 to 20.21 the sealing ring casings at the driving shaft are to be
             provided with cooling water. The connections are designed in G 1/4". All other blowers do not need
             a water cooling.
             External machined parts are coated with rust preventing varnish, and the inlet and outlet flanges
             are fitted with plastic caps to prevent the entry of dirt and water spray.
4PG-401EN page 4 of 14
0368-002
  Aerzener Maschinenfabrik GmbH
  Reherweg 28 / D-31855 Aerzen, Postfach 11 63 / D-31849 Aerzen, Tel.: 05154/810, Fax: 05154/81191
                                                                                                    cooling-
                                                                                                    water
                                                                                                    connection
discharge side
      3.     Notes on transportation
      3.1    The unit must be protected against jolts and impact during transportation.
      3.2    When lifting the unit by crane, do not use the free ends of the shaft nor the cast eyes on the side
             plates or the top of the housing: use instead a suitable hemp or wire rope sling placed around the
             side plates.
      3.3    When the unit arrives at its destination, check that it is undamaged and that the delivery is complete.
      4.     Storage
             If the units have to be stored before use, a dry, well protected space should be provided. If
             necessary, the rust preventing varnish coating on the machined surfaces should be renewed, using a
             rust preventing oil. If the unit has to be stored for a longer period and there is insufficient protection
             from dampness, the smooth faces of the flanges and the interior chambers of the blower must be
             coated with a conservation oil to prevent corrosion.
             Protective oils:
             External                         Oil chambers                                Conveying chamber
             TECREX 39 (MOBIL OIL)            ESSO LUB MZ 20 W/20                         Ballistol-oil
             RUST BAN 324 (ESSO)              SHELL Ensis Motor Del 20                    (biodegradable, no ground
             V-Produkt 9703 (SHELL)           MOBIL Mobilarma 523 or 524                  water contamination)
                                              AVIA Avilub MK 2000
             or other equivalent products offered by mineral oil manufacturers.
             Cleaning agent: e.g. Certrex 62 from Mobil or Varsol from Esso.
      5.     Installation
   4PG-401EN                                                                                                     page 5 of 14
0368-002
  Aerzener Maschinenfabrik GmbH
  Reherweg 28 / D-31855 Aerzen, Postfach 11 63 / D-31849 Aerzen, Tel.: 05154/810, Fax: 05154/81191
      5.1    Preparation
             Before transporting the unit to the prepared base, all surfaces which will come into contact with the
             base should be cleaned of oil and grease to ensure proper contact.
             Leave the plastic caps on the flange until the pipework is ready to be finally connected.
      5.4    Alignment
             Place the blower unit onto the foundation, and adjust it until it is accurately
             level, using steel shim plates (no wedges !). Use a machinists level on
             machined surfaces or on the drive shaft.
4PG-401EN page 6 of 14
0368-002
  Aerzener Maschinenfabrik GmbH
  Reherweg 28 / D-31855 Aerzen, Postfach 11 63 / D-31849 Aerzen, Tel.: 05154/810, Fax: 05154/81191
5.7 Keilriemen
             1. Consult the table to find the test force "f" appropriate to the type of belt used.
             2. Find the smallest-diameter pulley in the system, and use this to find the deflection "E" from the
             table.
             3. Calculate the deflection "Ea" from the actual shaft centre distance "e" using formula (1).
             4. Apply the test force "f" to the belt exactly midway between the two shafts (whose centre distance
                is "e") and exactly at right angles to its original (undeflected) path.
                Then tighten the belt until the deflection equals the correct calculated deflection "Ea".
               Belt tension example:    belt profile SPZ; dk = 100 mm; e = 380 mm; f = 2.5 daN; Ea = 5.5 mm
             The belts should be retightened after they have run for about 30 minutes.
4PG-401EN page 7 of 14
0368-002
  Aerzener Maschinenfabrik GmbH
  Reherweg 28 / D-31855 Aerzen, Postfach 11 63 / D-31849 Aerzen, Tel.: 05154/810, Fax: 05154/81191
Radial: max. 0.05 mm shaft misalignment (i.e. 0.1 mm total on a full revolution)
             Axial: max. 0.05 mm shaft misalignment over a complete revolution; if possible the misalignment
             should be kept lower than 0.03 mm at a distance r = 100 mm from the middle of the shaft
             (for distances other than this, calculate the corresponding tolerance in linear proportion).
5.9 Pipelines
             When installing the vacuum pipes, take particular care that the pairs of flanges are accurately parallel
             to one another (if necessary, use a feeler gauge to check), as otherwise they will be under strain and
             may disort when connected.
             The seal rings should be lightly greased with vacuum grease before being inserted. The weight of the
             piping and of any silencers etc. must be supported on separate brackets, and not carried by the flange.
             Once the flange bolts have been tightened, turn the blower over by hand and check that it turns easily.
             If any resistance is felt, then check that the blower has been mounted correctly without any
             mechanical strain or distortion. To do this, undo the flange connections and if necessary also the
             foundation anchoring bolts. Check the inside chambers of the blower for dirt.
             Note:
             Experience has shown, that, when starting up the blower for the first time, it is advisable to fit a strainer
             of 0.3 mm mesh size to the inlet side of the blower for the initial running-in period. The strainer should
             be of conical form, with the tip of the cone pointing AGAINST the direction of flow. The fine-mesh
             strainer should be supported on a perforated metal sheet.
             If the strainer is still clean after the first 200 hours operation, it can be removed.
      6.     Initial start-up
      6.1    Test run of drive motor
             Uncouple the blower, and check that the motor alone runs smoothly and in the correct direction. If any
             electrically-operated instruments are provided (e.g. thermometer, manometer with electrical contacts),
             these must be checked for correct functioning.
4PG-401EN page 8 of 14
0368-002
  Aerzener Maschinenfabrik GmbH
  Reherweg 28 / D-31855 Aerzen, Postfach 11 63 / D-31849 Aerzen, Tel.: 05154/810, Fax: 05154/81191
      7.     Maintenance
      7.1    General
             If run under normal operating conditions, a rotary piston blower needs scarely any maintenance. The
             rotary pistons do not touch metal at any point and thus do not need any lubricant.
      8.     Lubrication
      8.1    General
             Vacuum blowers are normally splash lubricated. In case of increased speed operation of vakuum
             blowers is admissible with an installed oil guiding device (wheel side) only. For reasens of space the
             installation of such an oil guiding device is possible in blowers sizes 14...20 only. Admissible
             application limits can be taken from the sheets 4TG-3381 and 4TG-3382. The correct oil level has to be
             checked at regular intervals. For this purpose th blower has to be switched off. Wait a few minutes
             until the oil has run down from the walls and the oil level is static.
4PG-401EN page 9 of 14
0368-002
  Aerzener Maschinenfabrik GmbH
  Reherweg 28 / D-31855 Aerzen, Postfach 11 63 / D-31849 Aerzen, Tel.: 05154/810, Fax: 05154/81191
Note: Through the oil filling opening it can be checked whether an oil feed device is installed.
             Special requirements:
             Oxidation stability at oil temperatures up to 110C.
             Special recommendations:
             In case of change-over from mineral to synthetic oil, an oil exchange is to be effected within an
             operation period of 24 h.
             It is not necessary to clean the oil chambers separately.
Concerning the following oil brands, good practical experiences are available:
Other oils brands may also be applied, provided the specification is observed.
             Before the test run the bearing and gear covers are be filled with the conservation oil
             ESSOLUB MZ 20W-20.
             After the mechanical test run the lube- and conservation oil is to be drained.
             The blower is delivered without lubricant filling.
             In order to avoid a dry-running of the seal rings of the driving shaft during commissioning on delivery
             of the blower stage the seal ring housing is filled with ARAL Motanol HV100.
4PG-401EN page 10 of 14
0368-002
  Aerzener Maschinenfabrik GmbH
  Reherweg 28 / D-31855 Aerzen, Postfach 11 63 / D-31849 Aerzen, Tel.: 05154/810, Fax: 05154/81191
8.4 Oil fillings (total, for drive and gear side together)
4PG-401EN page 11 of 14
0368-002
  Aerzener Maschinenfabrik GmbH
  Reherweg 28 / D-31855 Aerzen, Postfach 11 63 / D-31849 Aerzen, Tel.: 05154/810, Fax: 05154/81191
             When removing the piping the conveying chamber can be checked and cleaned.
             Adhesive and sticking deposits can be removed either with a scraper or an appropriate solvent on
             their nature.
             1) Extract oil
             2) Relocate feet, drive shaft is now at the bottom
             3) Exchange oil sight glasses and filler/drain
             4) Remove seal ring housing
             5) Lengthen pipe between seal ring housing and oil reservoir
             6) Mount seal ring housing with oil reservoir vertical
             7) Fill up oil in accordance with the operating instruction
                              Aerzener Maschinenfabrik
                              GmbH
                              Reherweg 28                                 Postfach 11 63
                              D-31855Aerzen                              D-31849Aerzen
4PG-401EN page 12 of 14
0368-002
  Aerzener Maschinenfabrik GmbH
  Reherweg 28 / D-31855 Aerzen, Postfach 11 63 / D-31849 Aerzen, Tel.: 05154/810, Fax: 05154/81191
GMa / GMb
GLa / GLb
      item    denomination                            GMa / GLa         GMb / GLb        GMb / GLb         GMb / GLb
                                                                         14...HV
                                                     10...-13... HV    GMb 17...HV        15...HV           16...HV
4PG-401EN page 13 of 14
0368-002
  Aerzener Maschinenfabrik GmbH
  Reherweg 28 / D-31855 Aerzen, Postfach 11 63 / D-31849 Aerzen, Tel.: 05154/810, Fax: 05154/81191
      normal speed                          4TG - 3381                     higher speed with oil feed device
   blower       pressure           speed       motor   theor. intake   pressure          speed       motor      theor. intake
                differ.                                                differ.
      4 ) (a) *GMa/b 15.10 and *GMa/b 15.11 at speed greater than 3000 1/min P max = 15 kW res. 18,5 kW.
      5 ) Types with *): GMa - type only spare blowers.
      normal speed                          4TG - 3382                       higher speed with oil feed device
               press.diff.   speed     motor    blower     theor. intake press.diff.  speed       motor blower       theor. intake
                                                pulley d                                                 pulley d
0368-002