ACCSYS
Document Ref :
WORK INSTRUCTION FOR ACEL/WI/AA01
ALARM ANNUNCIATOR Date Effective :
01/07/2017
1. PURPOSE
Making of Alarm Annunciator
2. SCOPE
Making an alarm Annunciator without any defect to achieve 0% complaint
3. REFERENCES
ACEL/WI/AMM02
ACEL/WI/SI03
ACEL/WI/HRC04
ACEL/WI/CRO05
ACEL/WI/VI10
4. TOOLS and EQUIPMENT
Multimeter
Heat Run Chamber
Soldering Iron
CRO ( Cathode Ray Oscillascope)
5. INSTRUCTIONS
1. Receiving the work indent which includes Job Code , Unit details , Delivery Date.
2. Preparing the material list as per the layout drawing and to be produced to store.
3. Collecting the materials from store
4. Assembling of parts in PCB and start soldering
5. Checking of Visual Inspection.
6. Cleaning of the assembled unit with spray and dry in the oven for 48Hrs under 55deg C.
7. Checking the CPU Board Voltage by using Multimeter.
8. Checking the Input , Output and Communication of the Alarm Annunciator.
9. Transferring to QC for Final Inspection.
ACCSYS
Document Ref :
WORK INSTRUCTION FOR ACEL/WI/AA01
ALARM ANNUNCIATOR Date Effective :
01/07/2017
6. QUALITY RECORDS
Record ID Owner Location Record Media Retention/Disposition
ACEL/WI/AA01 Production Incharge Production Dept File -
7. CHANGE HISTORY LOG
Revision Effective Date Description of Changes Approved By
01 01/07/2017 Titles Given
Prepared By Reviewed By Approved By