51 - Interface With Staad Pro - Doc
51 - Interface With Staad Pro - Doc
From these two methods, we recommend importing using through OpenSTAAD function.
                                                                                                   1
Staad Pro
Select Analysis Engine Dialog Window as below is shown. Click Run Analysis to run structure analysis.
Note : LOAD LIST above the PRINT SUPPORT REACTION menu , which is one of the input files in
STAAD.Pro, should have both LOAD CASE and LOAD COMBINATION, since the calculation of LOAD
COMBINATION needs both VALUE and FACTORS of LOAD CASE in SUPPOT REACTION.
                                                                                                            2
Staad Pro
Choose Create New Structure button. Add : New Structure Name dialog window will appear.
                                                                                                       3
Staad Pro
        Import from Structural Analysis Program dialog box will appear. Select the Load
         cases/Combination import from STAAD.PRO by toggling on the corresponding check box. Select
         Isolated from the Apply Foundation Type drop-down list box, and then click on the OK button.
      In case same load case occurs from AFES and the Staad, the file can not be imported. A warning
      message shall appear instead as Current structure found to have same load case as listed below to
      Staad file. Replace and try again.
                                                                                                        4
Staad Pro
      The figure below shows Staad model with the same load case names. Those load cases should be
      renamed so that the program will not be confused in reading it which may result for errors.
        The support coordinates; load cases and load combinations from STAAD.PRO analysis will be
         imported in the AFES program. As shown below, geometry data is automatically imported from
         the superstructure analysis output.
                                                                                                    5
Staad Pro
     The support coordinates; load cases and load combinations from STAAD.PRO analysis will be
     imported in the AFES program.
Click Save then Close buttons. The raft/mat foundation shall appear as shown below.
The load case window shows the load case name and values on the supports.
The imported load case and values can be verified by clicking on the Load Case button.
     The import wizard will automatically converts the values into the coordinates system used by the AFES
     program in order to complete the foundation design.
     The coordinate system of AFES is as follows:
Note: All loads at the top of pier are assumed to act at the center of the pier.
                                                                                                        6
Staad Pro
     Various imported Load Case values can be checked on the Load Case button and select the load case
     description on the Show State of load case function then you can verify from the table.
        Imported load combination and load factor values can be verified by clicking on the Load
         Combination command button.
     Note: For the imported load combinations, half is for stability check and the other half is for
     reinforcement and shear check.
     Load combination can be changed by choosing Elastic Strength or Ultimate Strength on the toggle
     button.
                                                                                                    7
Staad Pro
Join them as isolated foundation using the Assign Foundation Grouping command button.
                                                                                                 8
Staad Pro
        Select footing to combine as a group through the screen by dragging your mouse or by choosing
         from the Assigned node list table. Click arrow pointing to the left to un-assign them from the
         default group then click Save button.
                                                                                                         9
Staad Pro
Method 1:
Go to website below, and install the OpenSTAAD program.
http://www.reiworld.com
           Run the program by clicking OpenSTAAD.exe file, then the OpenSTAAD is started to install.
            Follow the steps in windows. Click Next to go to next step, and click Back to go backward.
           Choose a folder that you want to install the OpenSTAAD. Click Next to install the program in
            specified location, otherwise click Browse.
                                                                                                         10
Staad Pro
      If the copy of file is finished, window indicating the end of installing is shown, then click Finish to finish
      installation.
When Geometry, Load Case, and Load Combination Data are not imported from AFES even after installing
OpenSTAAD, follow the steps below.
C:\Program Files\GS_AFES\Help\ Troubleshooting of OpenStaad Program.pdf
                                                                                                                 11
Staad Pro
Method 2:
Put CD in CD-ROM drive.
Appoint the CD-ROM drive of AFES by running the OpenStaad Setting, then input the registered path and
OpenSTaadSet.exe.
When the program runs, input the Directory to install OpenSTAAD in Registered path. Click
command button, then OpenSTAAD is started to install.
This function is only available in STAAD.Pro 2003 and higher versions. Superstructure should be analyzed first
before choosing .std(Input File) file of Staad.Pro. If data file(*.std) can not be imported because of version of
Staad.Pro, you can use the attached file and document. Please find attached the Troubleshooting of OpenStaad
Program.pdf for your easy understanding.
                                                                                                              12
Staad Pro
    To import the Geometry, load case, and load combination data from other related software, the
     superstructure should be modeled and analyzed first.
                                                                                               13
Staad Pro
    Select any existing project in the Project Dialog Window. Below is example. Select ACI_MKS project,
     and then click on the OK button.
                                                                                                       14
Staad Pro
    Choose Create New Structure button. Add : New Structure Name dialog window will appear. Input
     structure name, and then click on the New button.
                                                                                                 15
Staad Pro
 You can import a STAAD.PRO model that has been successfully analyzed. To import a STAAD.Pro file,
 navigate to the directory in which the file is located, and then select the file and click on the Open button.
                                                                                                                  16
Staad Pro
    Import from Structural Analysis Program dialog box will appear. Select the Load cases/Combination
     import from STAAD.PRO by toggling on the corresponding check box. Select the foundation type that
     will be placed on the footing or mat to be analyzed and/or designed from Apply Foundation Type drop-
     down list box, and then click on the OK button.
    The support coordinates, load cases and load combinations from STAAD.PRO analysis will be imported
     in the AFES program. As shown below, geometry data is automatically imported from the superstructure
     analysis output.
                                                                                                      17
Staad Pro
     The load case window shows the load case name and values on the supports. The imported load case and
      values can be verified by clicking on the Load Case button.
   The import wizard will automatically converts the values into the coordinates system used by the AFES
   program in order to complete the foundation design.
   The coordinate system of AFES is as follows:
Note: All loads at the top of pier are assumed to act at the center of the pier.
Various imported Load Case values can be checked on the Load Case button and select the load case description
on the Show State of load case function then you can verify from the table.
                                                                                                           18
Staad Pro
    Imported load combination and load factor values can be verified by clicking on the Load Combination
     command button.
 Note: For the imported load combinations, half is for stability check and the other half is for reinforcement
 and shear check.
Load combination can be changed by choosing Elastic Strength or Ultimate Strength on the toggle button.
                                                                                                           19
Staad Pro
Join them as isolated foundation using the Assign Foundation Grouping command button.
    Select footing to combine as a group through the screen by dragging your mouse or by choosing from the
     Assigned node list table. Click arrow pointing to the left to un-assign them from the default group then
     click Save button.
                                                                                                          20
Staad Pro
21