IS:1823-1980
( Reaffirmed 2001 )
Indian Standard
SPECIFICATION FOR
FLOOR DOOR STOPPERS
( Third Revision )
Second Reprint MARCH 1992
UDC 683.374.6
@ Copyight 1980 .
BUREAU OF INDIAN STANDARDS
, i h$fNAK BHAVAN, 9 BAHADUR SHAH ZAFAR MARC
c NEW DELHI 110002
.9
Gr3 44 November 1980
/
IS: lb23-1980
Indian Standard
SPECIFICATION FOR
FLOOR DOOR STOPPERS
( Third Revision )
Builders Hardware Sectional Committee, BDC 15
Chairman Representing
SHRI YUSUP MOWnm M. C. Mowjee 8~ company Private Ltd.
Calcutta; and Builders Hardware Industries
Associatron of India, Calcutta
Members
&RI SAHIB SINOH (Alternate 30
Shri Yusuf Mowjee )
SHRI D. R. BAHL Engineer-in-Chiefs Branch, Army Head -
quarters, New Delhi
Sxinr S. G. MAHAJAN ( Alrermve )
SHRt D. S. CHAUHAN Regronal Testing Centre (Northern) (Ministry
of -Industry)
3x1~ A. K. DUGGAL( Alternate)
CONTROLLEROF STORE% Ministry of Railways
EASTERN RAiLWAY
SHRI S. IC. DUTTA Housing and Urban Development Corporation
Ltd, New Delhi
SHRI K. H. GANDHI Ministry of Defence (DGI)
SHRI VIJAY ICuhfAR (Alternate)
SHRI A. GHOSH National Test House, Calcutta
SHRI A. K. SARKAR ( Alternate )
SHRI R&K~SH KAhum Jayna Trading Corporation, Delhi
SHRINAWALKAnmol( Alternate))
SHRI S. C. KAFQOR Directorate General of Supplies & Disposals,
New Delhi
SHRI I. C.I&ANNA (Alternate )
F.
SHRI &AM_ -_~WALRAMANI Indian Institute of Architects, Bombay
COL f;. C.KHANNA Argent Industries, New Delhi
MA&EN K. D. CHADHII ( Alternate 1
SHRI AJOYENDUEXUL Gobintutttheet Metal Works & Foundry,
Sttxr A&fI-rABHPAUL ( Afternate )
( Continued on gage 2 )
@ CepytW 1980
BUREAU OF INDIAN STANDARDS
This p&&on is protected under the M&n Cowright Act ( XIV of 1957 ) and
rep&&rcti&&t Thale .or in parf. by &ny means. except with writteripermition of- the
oubhsher shallbe deemed to be, an infringement of. copyright under the said Act.
IS :1823 - i980
( Continued from page 1 )
Members Represenhg
SHRI K. PURKAYASTHA Indian Aluminium
Co Ltd. Calcutta
SHRI R. K. MEHTA ( Alrcmare 1
DR A. V. R. RAO National Buildings Organization, New Delhi
SHRI 0. P. R~I-RA ( Alremale )
SHRI H. S. SETHI Excritc Sales Corporation, New Delhi
SHRI Y. D. SAIGAL ( Alternare )
SHRI T. C. SOLANKI Scn-Harvic Ltd. Bombay
SHRI N. K. RAGOOWAF~HI ( Altemure 1
SUPERINTENDINGSURVEYOROF Central Public Works Department, New Delhi
WORKS ( DA2 )
SURVEYOROF WORKS ( DA2 ) ( Alrernure )
SHRI G. RAMAN, Director General. ISI ( Ex-oficio Member )
Director ( Civ Engg )
Secrelrrry
&RI S. SBNGUPTA
Assistant Director (.Civ Engg ), ISI
Door and Window Fittings Subcommittee, BDC IS : 1
Convener
SXRI:YUSUF MOWJEE M.~~~ut~wjce & Company Private Ltd.
Members
SHR~ SAHIB Smcm ( AIfemuIe lo
Shri Yusuf Mowjee)
Slnu D. S. CHAUHAN Regional Testing Centre ( Nor them ) ( Ministry
of Industry )
Sm A. K. DUWAL ( Alremate)
SHIU JASWANT SINGH astern Commercial dt Industrial Enterprises
Pvt Ltd, Vishakhapatnam
SW RAVI MEHRA ( Alfemcrrr )
SHRI M. R. JOSHI Resca& & Development Organization. New
SHIU S. SEMALBRI ( Alfemufe )
SHRI bSH -MBoJ Jayna Trading Corporation, Delhi
SHRI NAWAL KAMBOI ( Allemate 1
SHIU I.. C. KHANNA Directorate General of Supplies & Disposals,
( Ministry of Supply ), New Delhi
COL P. C. KHA~A +rgant Indurtrics. New Delhi
MN-GEN K. D. CIUDHA ( Alremute 1
hflU AJOYB!UDUPAUL Gobgeuttiheet Metal Works & Fouadry.
SHRJAMITABH PAUL ( Atmnufe )
SHRI V. K. RJNI Ministry of Railway8
SHRI H. K. bKPiR.4 Engineer-ia-$%efa Branch, Army Iieadquuteti
Sm B. D. KSHIRSAOAR ( Almmfe )
Everite Soles Corporation, New Delhi
*TH;; p&GAL ( .&em)
&~BY~R~P~W~RK~ (DAZ) Central Public Works Deprtment. NOWDatbi
44 I
2
IS:1823-1980
Indian Standard
SPECIFICATION FOR
FLOOR DOOR STOPPERS
( Third Revision )
0. FOREWORD
0.1 This Indian Standard ( Third Revision) was adopted by the Indian
Standards Institution- on 24 January 1980, after the draft finalized by
the Builders Hardware Sectional Committee had been approved by the
Civil Engineering Division Council.
0.2 The specification for floor door stoppers was first published in 1962 and
revised in 1968, and the second revision was issued in 1974. In the third
revision the improvement made by the industry in the manufacture of floor
door stoppers have been incorporated. To satisfy the functional require-
ments better certain dimensions have .been kept binding, and certain
new dimensions have been introduced to ensure interchangeability. Some
new material for the manufactureof body and cover plate have also been
introduced.
0.3 For the purpose of deciding whether a particular requirement of
this standard is complied with, the final value, observed or calculated,
expressing the result of a test or analysis, shall. be rounded off in
accordance with IS : 2-1960*. The number of significant places retained in
the rounded off value should be the same as that of the specified value
in this standard.
1. SCOPE.
1.1 This standard lays down the requirements for floor door stopper
suitable for use with .door &utters of 30, 35, 40 and 45 mm thickness.
2. MATERIALS
2.1 Materials used for the manufacture of various components of floor
door stiipv s shall conform to those given in Table ,l.
I y
*R&S for %eu,ndinpoff numerical values ( revised ).
44 3
IS : 1823 - 1980
3. DIMENSIONS AND TOLERANCES
3.1 The leading dimensions and tolerances thereon shall be as given
in Table 2 read with Fig. 1,
NOTE- The shape of the floor door stopper is only illustrative but the
dimensions and minimum requirements are binding.
TABLE 1 REQUIREMENTS FOR MATERIAL FOR
FLOOR DOOR STOPPERS
( Cfuusc 2.1 )
PART MATERIAL
ii:.
(1) (2) (3)
i) Body or housing Aluminium alloy pressure IS Designation 4600 or
and cover plate die castings 5230 of IS : 61%1975*
Aluminium alloy sheqts IS Designation 52000 or
65032 of IS : 737-1974t
Brass sheet CuZn40 of IS : 410-1977t
Cast brass Grade 3 of IS : 292-1961s
Brass gravity die casting CuZn40 of IS : 1264-196511
ii) Spring Phosphor bronze Grade I of IS : 76083975~
Hard drawn rteel wire Grade 2 of IS : 4454
(Part I r-1975
iii) Tongue Aluminium alloy Grade 4600 or 522300
pressure die casting of IS : 617-1975.
Cast brass Grade 3 of IS: 292-1961)
Nylon Suitable grade
Plastic Suitable grade
*Specification for aluminium and aluminium alloy ingots and castings for general
engineering purposes ( second revision ).
tspecification for wrought aluminium and aluminium alloyr, sheet and strip ( for
general engineering purposes ) ( second revkim ).
$Specitlcation for cold rolled brass sheet, strip and foil ( third revision ).
$&ecification for brass ingots and castings (m&cd).
1lSpecification for brass ingots for gravity die castingsand brass gravity die castioos
( including naval brass ) ( rerissd).
((ISpecification for phosphor bronze wires ( for general engineering purposes ).
l*SpeciScation for steel wires for cold formed springs : Part I Patented atadcold
Ibrpnn steel wires - unalloyed (firer nvision ).
ls:1823-1980
1A CAST TVPE
18 CAST BODY Of? HOUSINO WITH
SHEET METAL COVER
All dimensions in millimetros.
FIG.1 TYPICAL ILLUSTRATIONOF Floor Door STOP~IQ
IS : 1823- 1980
TABLE 2 DIMENSIONS AND TOLERANCES OF FLOOR
DOOR STOPPERS
( Clauses 3.1, 4.2 and Fig. 1 )
All dimensions in millimctres.
THICK- A B C TI ~UNTERSUNK WOOD t?iCKE-
NESS Min r---h-- f--------?
OF Casting Sheet Screw Screw No. of
Desig- Desig- Hole-s
S%% nation dation
for for
Cast- Sheet
ing Metal
(1) (2) (3) (4) (5) (6) (7) (8) (9)
30 35 140 13 45 3 9 8 4
35 40 140 8 4.5 3 9 8 4
40 45 150 13 45 3 9 8 4
45 50 150 6 4.5 3 9 8 4
TOLB- -+@5 50.5 - +@3 +@3 - - -
RANCPS -0 -0
4. MANUFACTURE
4.1 The floor door stoppers shall be well made and shall be free
from defects likely to prevent its correct fixing or affect adversely its
reliability in use.
4.2 The body or housing of the door stopper shall be cast or manufactured
in one piece and shall be fixed to the cover plate by means of brass
or aluminium screws. The screw! for fixing the cover *plate to the body
;ha,illbe countersunk head machmed screws, conforrnrng to IS : 1365-
. The body and the cover plate shall be either of aluminium alloy
casting or aluminium alloy~aheet, or cast brash or brass sheet. There shah
be four countersunk holes for fixing the door stoppers to the floor.
The screw n&s shah be suitable for countersunk head wood screws
conforming to IS.: 676031972j and of sixes as specified in Table 2.
~$pecification for slotted countersunk head screw ( third revision ).
tS$yiffation for slotted countersunk head wood screws.
G 6
/
IS : 1823- 1980
4.3 The stoppers shall be provided with one wire spring which shall
comply with the material specified in Table 2. The spring shall be fixed to
a 8 mm diameter pin as shown in Fig. 1. The pin shall be either
of brass or aluminium or mild steel.
4.4 The ngue shah preferably be of the same material as used for
the body housing except when the tongue is made of nylon or ,plas-
tics. The tongue which would be pressed while closing or opening of the
door shall be connected to the lower part by means of a copper pin of suit-
able size as shown in Fig. 1.
4.5 On the extreme end, a rubber piece shall be attached to absorb
shocks due to the pulling action of the door as shown in Fig. 1. The rubber
used shall comply with the. requirement given in .Tabie 3. The rubber
piece may be fixed to the cover plate by means of brass or mild steel
screws.
TABLE 3 REQUIREMENIS FOR RUBBER FOR USE IN FLOOR
DOOR STOPPERS
PART&XAas Raqu- RE!mNo RmcEDuRR
(1) (2) (3) (4)
i) Relative density, MUX l-3 IS : 3400( Part Ix >197s*
ii) Hardness w.zs IS:mo(PartII)-196s.
iii) Ageing for 24 h at a) Change in IS : 3400 (Part 11)-1%5*
loo f 1oc initial hardness
+5,-O ind
b) Shall not deva- IS : 3400( Part IV )-lP7ff
lop brittlencsr
or tackinek
Methods of test for vulcanized tubbers
Part JX Density (first nvisian ).
Part II Hardness.
Part&J Accelerated ageing ( firsrrevision ).
i:
i9
7
/ 1
IS : 1823- 1980
5. WORKMANSHIP AND FINISH
5.1 Door stoppers shall be free from flaws and defects of, all kinds. All
burrs and sharp edges shall be removed. It shall be free from surface
and casting defects. Aluminium door stopper shall be anodized and the
anodic coating shall not be less than Grade AC 1.0.of IS : 1868- 1968*. Brass
stoppers shall be finished smooth. Stoppers may also be chromium or
nickel plated, anodized or oxidized, if so desired by the purchaser.
5.2 The exterior of the door stopper shall be in flush with the floor and
shall be finished bright or satin.
6. MARKING
6.1 Each door stopper shall be clearly and permanently marked with
the following information:
a) Name of the manufacturer or trade-mark, and
b) Size of shutter for which it is suitable.
6.2 The door stoppers may also be marked with the ISI Certification Mark.
Nom - Ihe use of the IS1 Certification Mark is governed by the provisions of
the Indian Standards Institution ( Certification Marks ), Act and the Rules and
Regulations made thereunder. The IS1 Mark on products covered by an Indian
Standard conveys the assurance that they have been produced to comply with the
requirements of that standard under a well-defined system of inspection, testing
and quality control which is devised and supervised by IS1 and operated by the pro-
ducer. ISImarked products are also continuously checked by IS1 for conformrty
to that standard as a further safeguard. Details of conditions under which a licence
for the use of the IS1 Certification Mark may be granted to manufacturers or
processors. may be obtained from the Indian Standards Institution.
7. PACKING
7.1 Each door stopper shall be suitably wrapped in craft paper or poly-
ethylene paper to avoid ingress of moisture during storage. It shall further
be packed in cardboard boxes.
7.2 Each cardboard box shall be marked with the following:
a) Manufacturers name or trade-mark,
b) Size of shutter to which the stopper is suitable,, and
c) Quantity in the package.
,i ;
~*S&$cjncatlon
for anodic coatings on aIqminium (first midon ).
G 8
/
IS : 1823 - l!W
8. SAMPLING AND CRITERION FOR CONFORMITY
8.1 The method of sampling and criterion for conformity shall be as
given in Appendix A.
APPENDIX A
( Clause 8.1 )
SAMPLING OF FLOOR DOOR STOPPERS
A-l. SCALE OF SAMPLING
A-l.1 Lot-In any consignment all the ffoor door stoppers of same shape,
size and manufactured from similar. materials under identical condition
shall be grouped together to constitute a lot.
A-1.2 The number of floor door stoppers to be selected from a lot
shall depend on the size of the lot and shall be in accordance with co1 1
and 2 of Table 4.
A-l.3 These stoppers shall be selected at random from at least 10 percent
of the randomly selected packages subject to a maximum of three, equal
number of stoppers being selected from each such package.
TABLE 4 SCALE OF SAMPLING AND CRITERION FOR CONFORh.,fMy
( Clauses A-l .2 andA-3.1 )
LOT SIZE SAMPLE SIZE Nuwm OF
PERMISSIBLE
DE~c;~~;~~ DOOR
(1) (2) (3)
up to loo 5 6
101 to 300 20 1
301 to 500 32 2
501 to loo0 50 3
80 5
l +I Td
0 ab0ve
i
9
i/
Is:1823-194)O
A-2.NUMBER OF TESTS
A-2.1
Allthefloor door stoppers selected as in A-l.2shall be checked
for dimensional requirements, materials, manufacture and %I&&. Any
%oor door stopper which fails to satisfy any one or more of these re-
quirements shall be considered as a defective door stopper.
~-3. C~WON FOR CONFORMITY
A-3.1 A lot shall be considered as conforming to the requirements of
this standard if the number of defective %oor door stoppers among those
tested does not exceed the corresponding number given in co1 3 of Table 4;
otherwise it shall be considered as not conforming to the requirements
of this standard.
10
BUREAU OF INDIAN STANDARDS
Headquarters:
Manak Bhavan, 9 Bahadur Shah Zafar Marg, NEW DELHI 110002
Telephones: 331 01 31, 331 13 75 Telegrams: Manaksanstha
( C mmon to all Offices)
Regional Offices: 4 Telephone
Central : Manak Bhavan, 9 Bahadur Shah Zafar Marg. 331 01 31
NEW DELHI 110002 331 1375
.Eastern : 1 /14 C. I. T. Scheme VII M, V. I. P. Road, 36 24 99
Maniktola, CALCUTTA 700054
Northern : SC0 445-446, Sector 35-C, I 21843
CHANDIGARH 160036 3 16 41
41 24 42
s 8outhern : C. I. T. Campus, MADRAS 600113 1 41 25 19
! (41 2916
tWestern : Manakalaya, E9 MIDC, Marol, Andheri ( East ), 6 32 92 95
1i *:
BOMBAY 400093
Branch Offices:
Pushpak. Nurmohamed Shaikh Marg, Khanpur, 2 63 48
AHMADABAD 380001 I 2 63 49
SPeenya Industrial Area 1st Stage, Bangalore Tumkur Road 38 49 55
BANGALORE 560058 38 49 56
I
Gangotri Complex, 5th Floor, Bhadbhada Road, T. T. Nagar, 667 16
BHOPAL 462063
Plot No. 82183, Lewis Road. BHUBANESHWAR 751002 5 36 27
53j5. Ward No. 29, R.G. Barua Road, 5th Byelane, .3 31 77
GUWAHATI 781003
5-8-56C L. N. Gupta Marg ( Nampally Station Road ), 231083
HYDERABAD 500001
.63471
R14 Yudhister Marg. C Scheme, JAIPUR 302005
{ 6 98 32
21 68 76
11 I/418 B Sarvodaya Nagar, KANPUR 298005
{ 21 82 92
Patliputra Industrial Estate, PATNA 800013 6 23 05
T.C. No. 14/l 421. University P.O.. Palayam J6 21 04
TRlVANDRUM 695035 16 21 17
Inspection Offices ( With Sale Point ):
Pushpanjali. First Floor, 205-A West High Court Road, 2 51 71
Shankar Nagar Square, NAGPUR 440010
Institution of Engineers ( India ) Building, 1332 Shivaji Nagar, 5 24 35
; . PUNE 411005 .,
Street.
%ales
?Mcutta in Calcutta is at 6 Chowringhee
Office700072 Approach, P. 0. Princep 27 6s 00
$$,@es Office in Bombay iS at Novelty Chambers, Grant Road, 89 66 28
Bombay 400007
$$ales Office in Bangalore is at Unity Boilding, Narasimharaja Square, 22 36 71
Bangalore 560002
Reprography Unit, BIS, New Delhi, India
_-