JEDEC

STANDARD

HERMETICITY

JESD22-A109B
(Revision of JESD22A-109A, July 2001)

NOVEMBER 2011

JEDEC SOLID STATE TECHNOLOGY ASSOCIATION


NOTICE

JEDEC standards and publications contain material that has been prepared, reviewed, and
approved through the JEDEC Board of Directors level and subsequently reviewed and approved
by the JEDEC legal counsel.

JEDEC standards and publications are designed to serve the public interest through eliminating
misunderstandings between manufacturers and purchasers, facilitating interchangeability and
improvement of products, and assisting the purchaser in selecting and obtaining with minimum
delay the proper product for use by those other than JEDEC members, whether the standard is to
be used either domestically or internationally.

JEDEC standards and publications are adopted without regard to whether or not their adoption
may involve patents or articles, materials, or processes. By such action JEDEC does not assume
any liability to any patent owner, nor does it assume any obligation whatever to parties adopting
the JEDEC standards or publications.

The information included in JEDEC standards and publications represents a sound approach to
product specification and application, principally from the solid state device manufacturer
viewpoint. Within the JEDEC organization there are procedures whereby a JEDEC standard or
publication may be further processed and ultimately become an ANSI standard.

No claims to be in conformance with this standard may be made unless all requirements stated in
the standard are met.

Inquiries, comments, and suggestions relative to the content of this JEDEC standard or
publication should be addressed to JEDEC at the address below, or refer to www.jedec.org under
Standards and Documents for alternative contact information.

Published by
JEDEC Solid State Technology Association 2011
3103 North 10th Street
Suite 240 South
Arlington, VA 22201-2107

This document may be downloaded free of charge; however JEDEC retains the
copyright on this material. By downloading this file the individual agrees not to
charge for or resell the resulting material.

PRICE: Contact JEDEC

Printed in the U.S.A.


All rights reserved
PLEASE!

DONT VIOLATE
THE
LAW!

This document is copyrighted by JEDEC and may not be


reproduced without permission.

Organizations may obtain permission to reproduce a limited number of copies


through entering into a license agreement. For information, contact:

JEDEC Solid State Technology Association


3103 North 10th Street
Suite 240 South
Arlington, VA 22201-2107

or refer to www.jedec.org under Standards and Documents


for alternative contact information.
JEDEC Standard No. 22-A109B
Page 1

TEST METHOD A109


HERMETICITY

(From JEDEC Board Ballot, JCB-11-71, formulated under the cognizance of the JC-14.1
Subcommittee on Reliability Test Methods for Packaged Devices.)

1 Scope

Testing for hermeticity on commercial product is not normally done on standard molded devices
that are not hermetic. Commercial product that this test method applies to has a construction that
produces a hermetic package; examples of this are ceramic and metal packages.

Most of these tests are controlled and updated in the military standards, the two standards that
apply are MIL-STD-750 for Discretes, & MIL-STD-883 for microcircuits. The test within these
standards can be used for all package types.

Within these standards the tests are similar; MIL-STD-750 Test Method 1071 Hermetic Seal is
recommended for any commercial hermetic requirements.

For MIL-STD-883 the applicable test method is 1014 Seal.

Test Method A109B


(Revision of Test Method A109-A)
JEDEC Standard No. 22-A109B
Page 2

Annex A (informative) Differences between JESD22-A109B and JESD22-A109-A

This section briefly describes most of the changes made to entries that appear in this standard,
JESD22-A109B, compared to its predecessor, JESD22-A109-A (July 2001).

Clause Description of Change

Rewrite of total doc to point to Military standards.

Test Method A109B


(Revision of Test Method A109-A)
Standard Improvement Form JEDEC JESD22-A109B

The purpose of this form is to provide the Technical Committees of JEDEC with input from the
industry regarding usage of the subject standard. Individuals or companies are invited to submit
comments to JEDEC. All comments will be collected and dispersed to the appropriate
committee(s).
If you can provide input, please complete this form and return to:
JEDEC Fax: 703.907.7583
Attn: Publications Department
3103 North 10th Street
Suite 240 South
Arlington, VA 22201-2107

1. I recommend changes to the following:


Requirement, clause number

Test method number Clause number

The referenced clause number has proven to be:


Unclear Too Rigid In Error

Other

2. Recommendations for correction:

3. Other suggestions for document improvement:

Submitted by
Name: Phone:
Company: E-mail:
Address:
City/State/Zip: Date:

You might also like