Technical Site Survey Report (TSSR)

This technical site survey report summarizes findings from surveying the KANDE site located in Nkhatabay, Malawi. Key findings include: - The site has an existing 60m tower that can support additional equipment. - Space is available at 55m to mount new 3G antennas, and the available free space range for heights is 54-57m. - An existing 4.8KVA rectifier has capacity for new equipment, and a 32A circuit breaker is available. - Photos document the tower, equipment space, shelter, access road, and existing DC system to support upgrades.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
280 views7 pages

Technical Site Survey Report (TSSR)

This technical site survey report summarizes findings from surveying the KANDE site located in Nkhatabay, Malawi. Key findings include: - The site has an existing 60m tower that can support additional equipment. - Space is available at 55m to mount new 3G antennas, and the available free space range for heights is 54-57m. - An existing 4.8KVA rectifier has capacity for new equipment, and a 32A circuit breaker is available. - Photos document the tower, equipment space, shelter, access road, and existing DC system to support upgrades.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
You are on page 1/ 7

TECHNICAL SITE SURVEY REPORT

(TSSR)

SITE ID :___ MW0622___

SITE NAME :___KANDE______

Jun. 2014
3G SITE SURVEY SHEET

Site Name KANDE No MW0622 Date 12-08-2014


Location Town Nkhatabay
Site Type Airtel
Site Type Greenfield Rooftop Existing Structure Indoor Outdoor VDM Build Cell C Upgrade
GPS Position Measured During Survey Latitude S11.921706 Longitude E34.178791

ACCESS INFORMATION
Contact Person Number
Substitute Number
Access Days 12-08-2014 Access road Good Bad Very bad
Notes

TOWER N/A Existing New Tower Height 60 m


Antenna Height (2G) 57 m
Antenna Azimuth (2G) A Sector 0 B Sector 120 C Sector 240
Microwave Height 52 m
Tower Type Monopole Concrete Mono Pole Lattice Stub Enviro Spec Signboard Triangle
Other

Type of Loading Required Urban Rural Environ Strategic Rooftop/Stub


Terrain Category flat Tower Category .
Aviation Lights Motivated Metro Rural Paint Yes No Colour red and white
Notes There are too many microwaves.

EQUIPMENT SHELTER
N/A New Existing
Shelter Type N/A Isotherm Special
Equipment Space Available Unavailable
Cable Tray Space Available Unavailable
Size 2.4x2.8 2.4x2.4 2.0x2.0 Other
Feeder Entry Plate Existing New
Notes

OUTDOOR FOUNDATION
N/A New Existing Renovate

1
Concret base 3 m by 3 m
Notes

RF&RRU INSTALLATION
A Sector Jump cable size 1/2 Jump cable length 2m Qty 2
B Sector Jump cable size 1/2 Jump cable length 2m Qty 2
C Sector Jump cable size 1/2 Jump cable length 2m Qty 2
A Sector RRU mounting height 55m Fiber &DC Cable length 66m Qty 2
B Sector RRU mounting height 55m Fiber &DC Cable length 66m Qty 2
C Sector RRU mounting height 55m Fiber &DC Cable length 66m Qty 2
Ant Information
Proposal 3G Antenna Height 52m
Available free space range_______(54-57)m_____________________
Proposal Antenna Azimuth A Sector 0 B Sector 120 C Sector 240
Existing 2G Antenna type V-pole X-pole
H-Frame New Existing
Antenna Pole Yes No Qty 3 Length 2 m
Transmission Type Tie Cable Cable Microwave Satelite
Trunking (75x50) N/A PVC Steel Length 8m Paint Yes No Colour .
Antenna Mount Wall Mount Floor Mount Pole Mount
Access Workman Cage Platform Scaffolding Cherry Ricker Abseiling
Notes

DC INFORMATION
Existing Rec. Model Existing Capacity _4.8KVA___
Output Voltage +24V -48V
Existing circuit Breaker Detail:
Breaker Available Unavailable Capacity _32A___
Note:

First to shut down ________63*2+32*3_______________________________


Second to shut down _____________________________________________________________
Battery:
Battery Supplier/Type Existing Capacity _(2V,600AH)*24_ Group 1
Notes

2
SURVEY PHOTOS
The photo for Existing Tower

The position for 3G RRU& ANT.

The photo for site environment

3
The photo
for Site
location.

4
The photo
for existing
room
location or
outside
equipments

The photo
for Existing
DC.

5
The photo
for the space
for New
Equipment.

The photo
for access
road

You might also like