Valve Series - 10V Series
Pressures to 15,000 psi (1034 bar)
Tube Pressure
Outside Rating
Diameter Orifice psi (bar)
Size Connection Size Rated @ Room
Inches Type Inches (mm) Cv* Temperature**
Notes:
* CV values shown are for 2-way straight valve pattern. For 2-way
angle patterns, increase CV value 50%. (Based on water)
6
LOW FRICTION ALUMINUM POWDER COATED
BRONZE PACKING GLAND STAINLESS STEEL
5
Number of turns open
HANDLE
1 Vee Stem
CHOICE OF VEE OR
10 20 30 40 50 60 70 80 90 100
REGULATING STEM TIP METAL-TO-METAL SPEEDBITE "W" CONNECTIONS
(EXCEPT 1/2" SPEEDBITE SW)
SEATING
% of rated Cv
Ordering Procedure
For complete information on available stem types, optional connections and additional valve options, see Needle Valve Options section or contact
your Sales Representative. 10V Series valves are furnished complete with connection components, unless otherwise specified.
10V 4 07 1 XX
Valve Outside Diameter Stem/Seat Body Options
Series Tube Size Type Pattern
For extreme
2-1/8 07 - non-rotating 1 - two-way straight
temperature and other
4-1/4 Vee stem (on-off service) 2 - two-way angle options, see Valve
6-3/8 08 - non-rotating 3 - three-way, two on pressure Options.
8-1/2 regulating stem (tapered tip
4 - three-way, one on pressure
for regulating and shutoff)
5 - three-way, two stem
87 - Vee stem with replaceable
Note: Contact Sales for 1/16tube size or manifold valve
seat
see MVE Series.
88 - Regulating stem with
replaceable seat
2 All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold.
Valve Options Valve Maintenance
Extreme Temperatures Repair Kits: add R to the front of valve catalog
Standard Parker Autoclave valves with PTFE packing may be operated number for proper repair kit.
to 450F (232C). High temperature packing and/or extended stuffing (Example: R10V4071)
box is available for service from -100F (-73C) to 650F (343C) by Valve Bodies: Valve bodies are available. Order using the eight (8)
adding the following suffixes to catalog order number. digit part number found on the valve drawing or
TG standard valve with PTFE glass packing to 600F (316C). contact your Sales Representative for information.
GY standard valve with graphite braided yarn packing to 650F
Consult your Parker Autoclave Engineers representative for pricing on
(343C).
repair kits and valve bodies. Refer to the Tools, Installation, Operation
B standard valve with cryogenic trim materials and Telfon packing
and Maintenance section for proper maintenance procedures.
to -100F (-73C).
Parker Autoclave Engineers does not recommend compression sleeve con-
nections below -100F (-73C) or above 650F (343C). For additional valve
options, contact your Sales Representative.
2-Way Straight
10V2071 VEE 1/8** 0.094 1.50 0.75 0.31 1.06 0.81 1.38 3.00 0.62 0.17 3.75 0.56 0.31 0.62
10V2081 REG (3.18) (2.39) (38.10) (19.05) (7.87) (26.92) (20.57) (35.05) (76.20) (15.75) (4.32) (95.25) (14.22) (7.87) (15.75)
10V4071 VEE 1/4 0.125 2.00 1.00 0.56 1.19 1.69 3.00 0.97 0.22 4.44 0.69 0.38 1.00
10V4081 REG (6.35) (3.18) (50.80) (25.40) (14.22) (30.23) (42.93) (76.20) (24.64) (5.59) (112.78) (17.53) (9.65) (25.40) See
10V6071 VEE 3/8 0.125 2.00 1.00 0.62 1.19 1.69 3.00 0.97 0.22 4.31 0.69 0.38 1.00 Figure 1
10V6081 REG (9.53) (3.18) (50.80) (25.40) (15.75) (30.23) (42.93) (76.20) (24.64) (5.59) (109.47) (17.53) (9.65) (25.40)
10V8071 VEE 1/2 0.250 2.50 1.25 0.53 1.25 1.81 3.00 0.97 0.22 4.44 0.69 0.38 1.00
10V8081 REG (12.70) (6.35) (63.50) (31.75) (13.46) (31.75) (45.97) (76.20) (24.64) (5.59) (112.78) (17.53) (9.65) (25.40)
2-Way Angle
10V2072 VEE 1/8 0.094 1.50 0.75 0.31 0.81 1.56 3.00 0.62 0.17 3.94 0.56 0.31 0.62
10V2082 REG (3.18) (2.39) (38.1) (19.05) (7.87) (20.57) (39.62) (76.20) (15.75) (4.32) (100.08) (12.70) (7.87) (15.75)
10V4072 VEE 1/4 0.125 2.00 1.00 0.56 1.19 2.19 3.00 0.97 0.22 4.81 0.69 0.31 1.00
10V4082 REG (6.35) (3.18) (50.80) (25.40) (14.2) (30.23) (55.63) (76.20) (24.64) (5.59) (122.17) (17.53) (7.87) (25.40) See
10V6072 VEE 3/8 0.125 2.00 1.00 0.62 1.19 2.19 3.00 0.97 0.22 4.81 0.69 0.31 1.00 Figure 2
10V6082 REG (9.53) (3.18) (50.80) (25.40) (15.7) (30.23) (55.63) (76.20) (24.64) (5.59) (122.17) (17.53) (7.87) (25.40)
10V8072 VEE 1/2 0.250 2.50 1.25 0.53 1.25 2.50 3.00 0.97 0.22 5.06 0.69 0.38 1.00
10V8082 REG (12.70) (6.35) (63.50) (31.75) (13.5) (31.75) (63.50) (76.20) (24.64) (5.59) (128.52) (17.53) (9.65) (25.40)
3-Way / 2 on Pressure
10V2073 VEE 1/8** 0.094 1.50 0.75 0.31 1.06 0.81 1.69 3.00 0.62 0.17 4.06 0.56 0.31 0.62
10V2083 REG (3.18) (2.39) (38.10) (19.05) (7.87) (26.92) 20.57 (42.93) (76.20) (15.75) (4.32) (103.12) (12.70) (7.87) (15.75)
10V4073 VEE 1/4 0.125 2.00 1.00 0.56 1.19 2.19 3.00 0.97 0.22 4.81 0.69 0.38 1.00
10V4083 REG (6.35) (3.18) (50.80) (25.40) (14.22) (30.23) (55.63) (76.20) (24.64) (5.59) (122.17) (17.53) (9.65) (25.40) See
10V6073 VEE 3/8 0.125 2.00 1.00 0.62 1.19 2.19 3.00 0.97 0.22 4.81 0.69 0.38 1.00 Figure 3
10V6083 REG (9.53) (3.18) (50.80) (25.40) (15.75) (30.23) (55.63) (76.20) (24.64) (5.59) (122.17) (17.53) (9.65) (25.40)
10V8073 VEE 1/2 0.250 2.50 1.25 0.53 1.19 2.44 3.00 0.97 0.22 5.06 0.69 0.38 1.00
10V8083 REG
(12.70) (6.35) (63.50) (31.75) (13.46) (30.23) (61.98) (76.20) (24.64) (5.59) (128.52) (17.53) (9.65) (25.40)
G - Packing gland mounting hole drill size * H Dimension is with stem in closed position. For prompt service, Autoclave stocks
G1 - Bracket mounting hole size ** 1/8 straight and 3-Way/2 on pressure valves have offset select products. Consult factory.
Panel mounting drill size: 0.22 all valves. tube connections. All dimensions for reference only and subject to change.
M M G G1 M M
G1 G
M M G1 H N
G H
H N N
D D D1
C E E
D D1
E C C
B B B
A A A
All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold. 3
Outside Dimensions - inches (mm) Block
Catalog Stem Diameter Orifice Thick- Valve
Number Type Tube Diameter A B C D D1 E F G G1 H* M N ness Pattern
3-Way / 1 on Pressure
10V2074 VEE 1/8 0.094 1.50 0.75 0.31 0.81 1.56 3.00 0.62 0.17 3.94 0.56 0.31 0.62
10V2084 REG (3.18) (2.39) (38.1) (19.05) (7.87) (20.57) (39.62) (76.20) (15.75) (4.32) (100.08) (12.70) (7.87) (15.7)
10V4074 VEE 1/4 0.125 2.00 1.00 0.56 1.19 2.19 3.00 0.97 0.22 4.81 0.69 0.38 1.00
10V4084 REG (6.35) (3.18) (50.8) (25.40) (14.22) (30.23) (55.63) (76.20) (24.64) (5.59) (122.17) (17.53) (9.65) (25.40) See
10V6074 VEE 3/8 0.125 2.00 1.00 0.62 1.19 2.19 3.00 0.97 0.22 4.81 0.69 0.38 1.00 Figure 4
10V6084 REG (9.53) (3.18) (50.8) (25.40) (15.75) (30.23) (55.63) (76.20) (24.64) (5.59) (122.17) (17.53) (9.65) (25.40)
10V8074 VEE 1/2 0.250 2.50 1.25 0.53 1.19 2.44 3.00 0.97 0.22 5.06 0.69 0.38 1.00
10V8084 REG (12.70) (6.35) (63.5) (31.75) (13.46) (30.23) (61.98) (76.20) (24.64) (5.59) (128.52) (17.53) (9.65) (25.40)
2-Way Angle / Replaceable Seat
10V2872 VEE 1/8 0.094 1.50 0.75 0.31 0.81 1.28 1.56 3.00 0.62 0.17 4.50 0.56 0.31 0.62
10V2882 REG (3.18) (2.39) (38.10) (19.05) (7.87) (20.57) (32.51) (39.62) (76.20) (15.75) (4.32) (114.30) (12.70) (7.87) (15.75)
10V4872 VEE 1/4 0.125 2.00 1.00 0.56 1.12 2.13 2.25 3.00 0.97 0.22 6.00 0.69 0.38 1.00
10V4882 REG (6.35) (3.18) (50.80) (25.40) (14.22) (28.45) (54.10) (57.15) (76.20) (24.64) (5.59) (152.40) (17.53) (9.65) (25.40) See
10V6872 VEE 3/8 0.125 2.00 1.00 0.62 1.12 2.28 2.25 3.00 0.97 0.22 6.00 0.69 0.38 1.00 Figure 5
10V6882 REG (9.53) (3.18) (50.80) (25.40) (15.75) (28.45) (57.91) (57.15) (76.20) (24.64) (5.59) (152.40) (17.53) (9.65) (25.40)
10V8872 VEE 1/2 0.250 2.50 1.25 0.53 1.00 2.50 2.38 3.00 0.97 0.28 6.06 0.69 0.38 1.00
10V8882 REG
(12.70) (6.35) (63.50) (31.75) (13.46) (25.45) (63.50) (60.45) (76.20) (24.64) (7.11) (153.92) (17.53) (9.65) (25.40)
G - Packing gland mounting hole drill size * H Dimension is with stem in closed position. For prompt service, Autoclave
G1 - Bracket mounting hole size All dimensions for reference only and subject to change. stocks select products.
Panel mounting drill size: 0.22 all valves. Consult factory.
G1 M G1
G1 M M M
M M N G H N G
N G
H D D1
H D
D D E E
E C
D1
D1 C
C
B
C A
B B
A A
4 All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold.
Needle Valves - SW Series
Pressures to 15,000 psi (1034 bar)
Tube Pressure
Outside Rating
Diameter Orifice psi (bar)
Size Connection Size Rated @ Room
Inches Type Inches (mm) Cv* Temperature**
Notes:
* CV values shown are for 2-way straight valve pattern. For 2-way
angle patterns, increase CV value 50%. (Based on water)
6
POWDER COATED
STAINLESS STEEL
HANDLE
LOW FRICTION
5
Number of turns open
ALUMINUM
BRONZE PACKING
GLAND
LOCKING DEVICE
4
Regulating Stem
ANTI-EXTRUSION
BACK-UP RINGS
NON-ROTATING 3
STEM
ADJUSTABLE PACKING
BELOW THREADS 2
COLD WORKED
TYPE 316 SS
BODY IN FIVE
PATTERNS 1 Vee Stem
SPEEDBITE "SW"
0
TUBE
CONNECTIONS
(except 1/8" 10 20 30 40 50 60 70 80 90 100
CHOICE OF VEE METAL-TO-METAL SpeedBite W)
OR REGULATING
% of rated Cv
SEATING
STEM TIP
Ordering Procedure
For complete information on available stem types, optional connections and additional valve options, see Needle Valve Options section or contact
your Sales Representative. SW Series valves are furnished complete with connection components, unless otherwise specified.
SW 4 07 1 XX
Valve Outside Diameter Stem/Seat Body Options
Series Tube Size Type Pattern
For extreme
4-1/4 07 - non-rotating 1 - two-way straight
temperature and other
6-3/8 Vee stem (on off service) 2 - two-way angle options, see Valve
8-1/2 08 - non-rotating 3 - three-way, two on pressure Options.
regulating stem (tapered tip
4 - three-way, one on pressure
for regulating and shutoff)
5 - three-way, two stem
87 - Vee stem with replaceable
manifold valve
seat
88 - Regulating stem with
replaceable seat
All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold. 5
Valve Options Valve Maintenance
Extreme Temperatures Repair Kits: add R to the front of valve catalog
Standard Parker Autoclave valves with PTFE packing may be oper- number for proper repair kit.
ated to 450F (232C). High temperature packing and/or extended (Example: RSW4071)
stuffing box are available for service from -100F (-73C) to 650F Valve Bodies: Valve bodies are available. Order using the eight (8)
(343C) by adding the following suffixes to catalog order number. digit part number found on the valve drawing or
TG standard valve with PTFE glass packing to 600F (316C). contact your Sales Representative for information.
GY standard valve with graphite braided yarn packing to 650F
(343C).
B standard valve with cryogenic trim materials and Telfon packing Consult your Parker Autoclave Engineers representative for pricing on
to -100F (-73C). repair kits and valve bodies. Refer to the Tools, Installation, Operation
and Maintenance section for proper maintenance procedures.
Parker Autoclave Engineers does not recommend compression sleeve con-
nections below -100F (-73C) or above 650F (343C). For additional valve
options, contact your Sales Representative.
2-Way Straight
SW4071 VEE 1/4 0.187 2.00 1.00 0.38 1.62 1.19 2.00 3.00 0.75 0.22 4.50 0.62 0.38 0.75
SW4081 REG (6.35) (4.75) (50.80) (25.40) (9.65) (41.15) (30.23) (50.80) (76.20) (19.05) (5.59) (114.30) (15.75) (9.65) (19.05)
SW6071 VEE 3/8 0.250 2.00 1.00 0.47 1.62 1.19 2.00 3.00 0.75 0.22 4.50 0.62 0.38 0.75 See
SW6081 REG (9.53) (6.35) (50.80) (25.40) (11.94) (41.15) (30.23) (50.80) (76.20) (19.05) (5.59) (114.30) (15.75) (9.65) (19.05) Figure 1
SW8071 VEE 1/2 0.375 2.50 1.25 0.53 2.38 1.75 2.88 4.00 1.00 0.34 5.95 0.69 0.50 1.00
SW8081 REG (12.70) (9.53) (63.50) (31.75) (13.46) (60.45) (44.45) (73.15) (101.60) (25.40) (8.64) (151.37) (17.53) (12.70) (25.40)
2-Way Angle
SW4072 VEE 1/4 0.187 2.00 1.00 0.38 1.19 2.43 3.00 0.75 0.22 5.00 0.62 0.38 0.75
SW4082 REG (6.35) (4.75) (50.80) (25.40) (9.65) (30.23) (61.72) (76.20) (19.05) (5.59) (127.00) (15.75) (9.65) (19.05)
SW6072 VEE 3/8 0.250 2.00 1.00 0.47 1.19 2.19 3.00 0.75 0.22 5.00 0.62 0.38 0.75 See
SW6082 REG (9.53) (6.35) (50.80) (25.40) (11.94) (30.23) (55.63) (76.20) (19.05) (5.59) (127.00) (15.75) (9.65) (19.05) Figure 2
SW8072 VEE 1/2 0.375 2.50 1.25 0.53 1.75 3.38 4.00 1.00 0.34 6.45 0.69 0.50 1.00
SW8082 REG (12.70) (9.53) (63.50) (31.75) (13.46) (44.45) (85.85) (101.60) (25.40) (8.64) (163.83) (17.53) (12.70) (25.40)
3-Way / 2 on Pressure
SW4073 VEE 1/4 0.187 2.00 1.00 0.38 1.62 1.19 2.62 3.00 0.75 0.22 5.18 0.62 0.38 0.75
SW4083 REG (6.35) (4.75) (50.80) (25.40) (9.65) (41.15) (30.23) (66.55) (76.20) (19.05) (5.59) (131.57) (15.75) (9.65) (19.05)
SW6073 VEE 3/8 0.250 2.00 1.00 0.47 1.62 1.19 2.62 3.00 0.75 0.22 5.13 0.62 0.38 0.75 See
SW6083 REG (9.53) (6.35) (50.80) (25.40) (11.94) (41.15) (30.23) (66.55) (76.20) (19.05) (5.59) (130.30) (15.75) (9.65) (19.05) Figure 3
SW8073 VEE 1/2 0.375 2.50 1.25 0.53 2.38 1.75 3.62 4.00 1.00 0.34 6.70 0.69 0.50 1.00
SW8083 REG (12.70) (9.53) (63.50) (31.75) (13.46) (60.45) (44.45) (91.95) (101.60) (25.40) (8.64) (170.18) (17.53) (12.70) (25.40)
G - Packing gland mounting hole drill size * H Dimension is with stem in closed position. For prompt service, Autoclave stocks
G1 - Bracket mounting hole size All dimensions for reference only and subject to change. select products. Consult factory.
Panel mounting drill size: 0.22 all valves.
G1 M M M G1 M M
M G G
G1 H N
H N G
N
H D D1
D
D1
D E E
E C
C C
B B
A B A
A
2-Way Straight 2-Way Angle 3-Way / 2 on Pressure
6 All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold.
Outside Dimensions -inches (mm) Block
Catalog Stem Diameter Orifice Thick- Valve
Number Type Tube Diameter A B C D D1 E F G G1 H* M N ness Pattern
3-Way / 1 on Pressure
SW4074 VEE 1/4 0.187 2.00 1.00 0.38 1.19 2.43 3.00 0.75 0.22 5.00 0.62 0.38 0.75
SW4084 REG (6.35) (4.75) (50.80) (25.40) (9.65) (30.23) (61.72) (76.20) (19.05) (5.59) (127.00) (15.75) (9.65) (19.05)
SW6074 VEE 3/8 0.250 2.00 1.00 0.47 1.19 2.43 3.00 0.75 0.22 5.00 0.62 0.38 0.75 See
SW6084 REG (9.53) (6.35) (50.80) (25.40) (11.94) (30.23) (61.72) (76.20) (19.05) (5.59) (127.00) (15.75) (9.65) (19.05) Figure 4
SW8074 VEE 1/2 0.375 2.50 1.25 0.53 1.75 3.38 4.00 1.00 0.34 6.45 0.69 0.50 1.00
SW8084 REG (12.70) (9.53) (63.50) (31.75) (13.46) (44.45) (85.85) (101.60) (25.40) (8.64) (163.83) (17.53) (12.70) (25.40)
G - Packing gland mounting hole drill size * H Dimension is with stem in closed position. For prompt service, Autoclave
G1 - Bracket mounting hole size All dimensions for reference only and subject to change. stocks select products. Consult
Panel mounting drill size: 0.22 all valves. factory.
G1 M G1
G1 M M M
M M G G
N H N
H N G
D D1
H D
D D E
E
E C
D1
D1
C
B C
C A
B B
A A
All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold.
All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold. 7
WARNING
FAILURE, IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS AND/OR SYSTEMS DESCRIBED HEREIN OR RELATED ITEMS CAN CAUSE DEATH, PERSONAL INJURY
AND PROPERTY DAMAGE.
This document and other information from Parker Hannifin Corporation, its subsidiaries and authorized distributors provide product and/or system options for further investiga-
tion by users having technical expertise. It is important that you analyze all aspects of your application and review the information concerning the product or system in the current
product catalog. Due to the variety of operating conditions and applications for these products or systems, the user, through its own analysis and testing, is solely responsible
for making the final selection of the products and systems and assuring that all performance, safety and warning requirements of the application are met. The products described
herein, including without limitation, product features, specifications, designs, availability and pricing, are subject to change by Parker Hannifin Corporation and its subsidiaries at
any time without notice.
Offer of Sale
The items described in this document are available for sale by Parker Hannifin Corporation, its subsidiaries or its authorized distributors. Any sale contract entered by Parker will be
governed by the provisions stated in Parker's standard terms and conditions of sale (copy available upon request).
2013 Parker Hannifin Corporation | Autoclave Engineers is a registered trademark of the Parker Hannifin Corporation 02-0102SE January2013
Instrumentation Products Division Parker Hannifin Manufacturing Ltd. Caution! Parker Autoclave Engineers Valves, Fittings and Tools are
Autoclave Engineers Operation Instrumentation Products Division, Europe not designed to work with common commercial instrument tubing
8325 Hessinger Drive Industrial Estate Whitemill and will only work with tubing built to Parker Autoclave Engineers
AES Specifications. Failure to do so will void warranty.
Erie, Pennsylvania 16509-4679 USA Wexford, Republic of Ireland
PH: 814-860-5700 FAX: 814-860-5811 PH: 353 53 914 1566
8www.autoclave.com All general terms and FAX: 353 53of914
conditions 1582
sale, including limitations of our liability, apply to all products and services sold. ISO-9001 Certified
Needle Valves
Medium Pressure
15SM Series
Pressures to 15,000 psi (1034 bar)
www.autoclave.com
Needle Valves - 15SM Series
Pressures to 15,000 psi (1034 bar)
Tube Pressure
Outside Rating
Diameter Orifice psi (bar)
Size Connection Size Rated @ Room
Inches Type Inches (mm) Cv* Temperature**
Notes:
* CV values shown are for 2-way straight valve pattern. For 2-way
angle patterns, increase CV value 50%. (Based on water)
6
STAINLESS STEEL
T-HANDLE
5 Regulating Stem
Number of turns open
LOW FRICTION
T
ALUMINUM
NO ABLE
BRONZE PACKING
GLAND 4
AIL
3
V
ANTI-EXTRUSION
NON-ROTATING
A
BACK-UP RINGS
STEM
2
ADJUSTABLE PACKING
BELOW THREADS
COLD WORKED
TYPE 316 SS 1 Vee Stem
BODY IN TWO
PATTERNS
0
10 20 30 40 50 60 70 80 90 100
HIGH PRESSURE
CONED AND
THREADED
CONNECTIONS
CHOICE OF VEE
OR REGULATING
METAL-TO-METAL
SEATING % of rated Cv
STEM TIP
15SM 24 07 1 XX
Valve Outside Diameter Stem/Seat Body Options
Series Tube Size Type Pattern
For extreme
24-1-1/2 07 - non-rotating 1 - two-way straight
temperature and other
Vee stem (on-off service) 2 - two-way angle options, see
08 - non-rotating Valve Options.
regulating stem (tapered tip
for regulating and shutoff)
2 All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold.
Valve Options Valve Maintenance
Extreme Temperatures Repair Kits: add R to the front of valve catalog
Standard Parker Autoclave Engineers valves with PTFE packing may number for proper repair kit.
be operated from 0F (-17.8C) to 450F (232C). High temperature (Example: R15SM24071)
packing and/or extended stuffing box are available for service from Valve Bodies: Valve bodies are available. Order using the eight (8)
-423F (-252C) to 1200F (649C) by adding the following suffixes digit part number found on the valve drawing or
to catalog order number. contact your Sales Representative for information.
TG standard valve with PTFE glass packing to 600F (316C).
GY standard valve with graphite braided yarn packing to 800F (427C).
Consult your Parker Autoclave Engineers representative for pricing on repair
Note: Contact factory for pressure ratings using graphite yarn packing.
kits and valve bodies. Refer to the Tools, Installation, Operation and Mainte-
HT extended stuffing box valve with graphite braided yarn packing nance section for proper maintenance procedures.
to 1200F (649C).
B standard valve with cryogenic trim materials and PTFE packing to
-100F (-73C). Note: Caution should be exercised in proper selection of medium pressure tub-
ing based on actual operating conditions. Two tubing series available in some
LT extended stuffing box valve with PTFE packing and cryogenic trim
sizes: 15,000 psi (1034 bar) and 20,000 psi (1380 bar).
materials to -423F (-252C).
K anti-vibration collet and gland assembly
See needle valve options for stem and seat coating for erosive service.
2-Way Straight
15SM24071 VEE 1-1/2 0.937 5.75 2.88 1.00 5.25 3.75 6.38 23.75 0.75 10.98 1.88 1.50 2.25 See
15SM24081 REG (38.10) (23.80) (146.05) (73.03) (25.40) (133.35) (95.25) (161.93) (603.25) (19.05) (278.79) (47.63) (38.10) (57.15) Fig. 1
2-Way Angle
15SM24072 VEE 1-1/2 0.937 5.75 2.88 1.00 3.75 6.75 23.75 0.75 11.35 1.88 1.50 2.25 See
15SM24082 REG (38.10) (23.80) (146.05) (73.03) (25.40) (95.25) (171.45) (603.25) (19.05) (288.32) (47.63) (38.10) (57.15) Fig. 2
G - Packing gland mounting hole drill size * H Dimension is with stem in closed position. For prompt service, Parker
G1 - Bracket mounting hole size All dimensions for reference only and subject to change. Autoclave Engineers stock select
Panel mounting drill size: 0.75 all valves. products. Consult factory.
Figure 1 Figure 2
F
F
G1 M M
G1 M M N
H N
H D
D1 E
D
E
C C
B
A B
A
All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold. 3
WARNING
FAILURE, IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS AND/OR SYSTEMS DESCRIBED HEREIN OR RELATED ITEMS CAN CAUSE DEATH, PERSONAL INJURY AND PROPERTY DAMAGE.
This document and other information from Parker Hannifin Corporation, its subsidiaries and authorized distributors provide product and/or system options for further investigation by users having technical
expertise. It is important that you analyze all aspects of your application and review the information concerning the product or system in the current product catalog. Due to the variety of operating conditions
and applications for these products or systems, the user, through its own analysis and testing, is solely responsible for making the final selection of the products and systems and assuring that all performance,
safety and warning requirements of the application are met. The products described herein, including without limitation, product features, specifications, designs, availability and pricing, are subject to change by
Parker Hannifin Corporation and its subsidiaries at any time without notice.
Offer of Sale
The items described in this document are available for sale by Parker Hannifin Corporation, its subsidiaries or its authorized distributors. Any sale contract entered by Parker will be governed by the provisions
stated in Parker's standard terms and conditions of sale (copy available upon request).
2013 Parker Hannifin Corporation | Autoclave Engineers is a registered trademark of the Parker Hannifin Corporation 02-9225BE January2013
Instrumentation Products Division Parker Hannifin Manufacturing Ltd. Caution! Parker Autoclave Engineers Valves, Fittings and Tools are
not designed to work with common commercial instrument tubing
Autoclave Engineers Operation Instrumentation Products Division, Europe
and will only work with tubing built to Parker Autoclave Engineers
8325 Hessinger Drive Industrial Estate Whitemill AES Specifications. Failure to do so will void warranty.
Erie, Pennsylvania 16509-4679 USA Wexford, Republic of Ireland
PH: 814-860-5700 FAX: 814-860-5811 PH: 353 53 914 1566
www.autoclave.com FAX: 353 53 914 1582 ISO-9001 Certified
Needle Valves
Medium Pressure
SM Series
Pressures to 20,000 psi (1379 bar)
www.autoclave.com
Needle Valves - SM Series
Pressures to 20,000 psi (1379 bar)
Tube Pressure
Outside Rating
Diameter Orifice psi (bar)
Size Connection Size Rated @ Room
Inches Type Inches (mm) Cv* Temperature**
Notes:
* CV values shown are for 2-way straight valve pattern. For 2-way
angle patterns, increase CV value 50%. (Based on water)
6
POWDER COATED
STAINLESS STEEL
HANDLE 5 Regulating Stem
Number of turns open
LOW FRICTION
ALUMINUM ONE PIECE NON-ROTATING
BRONZE PACKING STEM
GLAND
4
LOCKING DEVICE
3
ANTI-EXTRUSION
BACK-UP RINGS
ADJUSTABLE PACKING
2
BELOW THREADS
COLD WORKED
TYPE 316 SS
BODY IN FIVE
1 Vee Stem
PATTERNS
0
MEDIUM
PRESSURE
CONED-AND-THR
10 20 30 40 50 60 70 80 90 100
EADED
CHOICE OF VEE
OR REGULATING
METAL-TO-METAL
SEATING
CONNECTIONS
% of rated Cv
STEM TIP
20SM 4 07 1 XX
Valve Outside Diameter Stem/Seat Body Options
Series Tube Size Type Pattern
For extreme
4-1/4 07 - non-rotating 1 - two-way straight
temperature and other
10SM 6-3/8 Vee stem (on-off service) 2 - two-way angle options, see
20SM 9-9/16 08 - non-rotating 3 - three-way, two on pressure Valve Options.
12-3/4 regulating stem (tapered tip
4 - three-way, one on pressure
16-1 for regulating and shutoff)
5 - three-way, two stem
87 - Vee stem with replaceable seat
manifold valve
88 - Regulating stem with replaceable seat
2 All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold.
Valve Options Valve Maintenance
Extreme Temperatures Repair Kits: add R to the front of valve catalog
Standard Parker Autoclave Engineers valves with PTFE packing may number for proper repair kit.
be operated from 0F (-17.8C) to 450F (232C). High temperature (Example: R20SM4071)
packing and/or extended stuffing box are available for service from Valve Bodies: Valve bodies are available. Order using the eight (8)
-423F (-252C) to 1200F (649C) by adding the following suffixes digit part number found on the valve drawing or
to catalog order number. contact your Sales Representative for information.
TG standard valve with PTFE glass packing to 600F (316C).
GY standard valve with graphite braided yarn packing to 800F (427C).
Consult your Parker Autoclave Engineersrepresentative for pricing on repair kits
Note: 3/4 rated 8000 psi (552 bar) and 1 rated 6000 psi (412 bar) maxi-
and valve bodies. Refer to the Tools, Installation, Operation and Maintenance
mum with graphite yarn packing. section for proper maintenance procedures.
HT extended stuffing box valve with graphite braided yarn packing
to 1200F (649C).
Note: Caution should be exercised in proper selection of medium pressure
B standard valve with cryogenic trim materials and PTFE packing to
tubing based on actual operating conditions. Two tubing series available in
-100F (-73C). some sizes: 15,000 psi (1034 bar) and 20,000 psi (1380 bar).
LT extended stuffing box valve with PTFE packing and cryogenic trim
materials to -423F (-252C).
K anti-vibration collet and gland assembly
See needle valve options for stem and seat coating for erosive service.
2-Way Straight
20SM4071 VEE 1/4 0.125 2.00 1.00 0.38 1.62 1.19 2.00 3.00 0.75 0.22 4.69 0.62 0.38 0.75
20SM4081 REG (6.35) (3.18) (50.80) (25.40) (9.65) (41.15) (30.23) (50.80) (76.20) (19.05) (5.59) (119.13) (15.75) (9.65) (19.05)
20SM6071 VEE 3/8 0.219 2.00 1.00 0.47 1.62 1.19 2.00 3.00 0.75 0.22 4.63 0.62 0.38 0.75
20SM6081 REG (9.53) (5.56) (50.80) (25.40) (11.94) (41.15) (30.23) (50.80) (76.20) (19.05) (5.59) (117.48) (15.75) (9.65) (19.05)
20SM9071 VEE 9/16 0.312 2.50 1.25 0.53 2.38 1.75 2.88 4.00 1.00 0.34 5.93 0.69 0.50 1.00
20SM9081 REG (14.29) (7.92) (63.50) (31.75) (13.46) (60.45) (44.45) (73.15) (101.60) (25.40) (8.64) (150.86) (17.53) (12.70) (25.40)
20SM12071 VEE 3/4 0.438 3.00 1.50 0.62 3.00 2.25 3.75 10.25 1.12 0.44 7.00 0.88 0.63 1.38
See
20SM12081 REG (19.05) (11.13) (76.20) (38.10) (15.75) (76.20) (57.15) (95.25) (260.35) (28.45) (11.18) (177.80) (22.35) (16.00) (35.05)
Figure 1
20SM16071 VEE 1 0.562 4.12 2.06 0.63 3.75 2.81 4.63 10.25 1.62 0.56 9.00 1.25 1.13 1.75
20SM16081 REG (25.40) (14.27) (104.65) (52.32) (16.00) (95.25) (71.37) (117.60) (260.35) (41.15) (14.22) (228.84) (31.75) (28.70) (44.4 5)
10SM9071 VEE 9/16 0.359 2.50 1.25 0.53 2.38 1.75 2.88 4.00 1.00 0.34 5.93 0.69 0.50 1.00
10SM9081 REG (14.29) (9.12) (63.50) (31.75) (13.46) (60.45) (44.45) (73.15) (101.60) (25.40) (8.64) (150.86) (17.53) (12.70) (25.40)
10SM12071 VEE 3/4 0.516 3.00 1.50 0.62 3.00 2.25 3.75 10.25 1.12 0.44 7.00 0.88 0.63 1.38
10SM12081 REG (19.05) (13.11) (76.20) (38.10) (15.75) (76.20) (57.15) (95.25) (260.35) (28.45) (11.18) (177.80) (22.35) (16.00) (35.05)
10SM16071 VEE 1 0.688 4.12 2.06 0.63 3.75 2.81 4.63 10.25 1.62 0.56 9.00 1.25 1.13 1.75
10SM16081 REG (25.40) (17.48) (104.65) (52.32) (16.00) (95.25) (71.37) (117.60) (260.35) (41.15) (14.22) (228.84) (31.75) (28.70) (44.45)
G - Packing gland mounting hole drill size * H Dimension is with stem in closed position. For prompt service, Parker
G1 - Bracket mounting hole size All dimensions for reference only and subject to change. Autoclave Engineers stock
Panel mounting drill size: 0.22 all valves. select products.
Consult factory.
Figure 1
F
G1 M M
H N G
D1
D
E
C
B
A
2-Way Straight
All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold. 3
Outside Dimensions - inches (mm) Block
Catalog Stem Diameter Orifice Thick- Valve
Number Type Tube Diameter A B C D D1 E F G G1 H* M N ness Pattern
2-Way Angle
20SM4072 VEE 1/4 0.125 2.00 1.00 0.38 1.19 2.44 3.00 0.75 0.22 4.81 0.62 0.38 0.75
20SM4082 REG (6.35) (3.18) (50.80) (25.40) (9.65) (30.23) (61.90) (76.20) (19.05) (5.59) (122.25) (15.75) (9.65) (19.05)
20SM6072 VEE 3/8 0.219 2.00 1.00 0.47 1.19 2.44 3.00 0.75 0.22 4.81 0.62 0.38 0.75
20SM6082 REG (9.53) (5.56) (50.80) (25.40) (11.94) (30.23) (61.90) (76.20) (19.05) (5.59) (122.25) (15.75) (9.65) (19.05)
20SM9072 VEE 9/16 0.312 2.50 1.25 0.53 1.75 3.38 4.00 1.00 0.34 6.43 0.69 0.50 1.00
20SM9082 REG (14.29) (7.92) (63.50) (31.75) (13.46) (44.45) (85.85) (101.60) (25.40) (8.64) (163.56) (17.53) (12.70) (25.40)
20SM12072 VEE 3/4 0.438 3.00 1.50 0.62 2.25 4.25 10.25 1.12 0.44 7.50 0.88 0.63 1.38
See
20SM12082 REG (19.05) (11.13) (76.20) (38.10) (15.75) (57.15) (107.95) (260.35) (28.45) (11.18) (190.50) (22.35) (16.00) (35.05)
Figure 2
20SM16072 VEE 1 0.562 4.12 2.06 0.63 2.81 5.12 10.25 1.62 0.56 9.00 1.25 1.13 1.75
20SM16082 REG (25.40) (14.27) (104.65) (52.32) (16.00) (71.37) (130.05) (260.35) (41.15) (14.22) (228.84) (31.75) (28.70) (44.4 5)
10SM9072 VEE 9/16 0.359 2.50 1.25 0.53 1.75 3.38 4.00 1.00 0.34 6.43 0.69 0.50 1.00
10SM9082 REG (14.29) (9.12) (63.50) (31.75) (13.46) (44.45) (85.85) (101.60) (25.40) (8.64) (163.56) (17.53) (12.70) (25.40)
10SM12072 VEE 3/4 0.516 3.00 1.50 0.62 2.25 4.25 10.25 1.12 0.44 7.50 0.88 0.63 1.38
10SM12082 REG (19.03) (13.11) (76.20) (38.10) (15.75) (57.15) (107.95) (260.35) (28.45) (11.18) (190.50) (22.35) (16.00) (35.05)
10SM16072 VEE 1 0.688 4.12 2.06 0.63 2.81 5.12 10.25 1.62 0.56 9.00 1.25 1.13 1.75
10SM16082 REG (25.40) (17.48) (104.65) (52.32) (16.00) (71.37) (130.05) (260.35) (41.15) (14.22) (228.84) (31.75) (28.70) (44.45)
3-Way / 2 on Pressure
20SM4073 VEE 1/4 0.125 2.00 1.00 0.38 1.63 1.19 2.63 3.00 0.75 0.22 5.00 0.62 0.38 0.75
20SM4083 REG (6.35) (3.18) (50.80) (25.40) (9.65) (41.28) (30.23) (66.68) (76.20) (19.05) (5.59) (127.00) (15.75) (9.65) (19.05)
20SM6073 VEE 3/8 0.219 2.00 1.00 0.47 1.63 1.19 2.63 3.00 0.75 0.22 5.00 0.62 0.38 0.75
20SM6083 REG (9.53) (5.56) (50.80) (25.40) (11.94) (41.28) (30.23) (66.68) (76.20) (19.05) (5.59) (127.00) (15.75) (9.65) (19.05)
20SM9073 VEE 9/16 0.312 2.50 1.25 0.53 2.38 1.75 3.63 4.00 1.00 0.34 6.51 0.69 0.50 1.00
20SM9083 REG (14.29) (7.92) (63.50) (31.75) (13.46) (60.45) (44.45) (92.08) (101.60) (25.40) (8.64) (165.59) (17.53) (12.70) (25.40)
20SM12073 VEE 3/4 0.438 3.00 1.50 0.62 3.00 2.25 4.63 10.25 1.12 0.44 7.88 0.88 0.63 1.38
See
20SM12083 REG (19.05) (11.13) (76.20) (38.10) (15.75) (76.20) (57.15) (117.48) (260.35) (28.45) (11.18) (200.03) (22.35) (16.00) (35.05)
Figure 3
20SM16073 VEE 1 0.562 4.12 2.06 0.63 3.75 2.81 5.88 10.25 1.62 0.56 9.75 1.25 1.13 1.75
20SM16083 REG (25.40) (14.27) (104.65) (52.32) (16.00) (95.25) (71.37) (149.35) (260.35) (41.15) (14.22) (247.89) (31.75) (28.70) (44.4 5)
10SM9073 VEE 9/16 0.359 2.50 1.25 0.53 2.38 1.75 3.63 4.00 1.00 0.34 6.52 0.69 0.50 1.00
10SM9083 REG (14.29) (9.12) (63.50) (31.75) (13.46) (60.45) (44.45) (92.08) (101.60) (25.40) (8.64) (165.59) (17.53) (12.70) (25.40)
10SM12073 VEE 3/4 0.516 3.00 1.50 0.62 3.00 2.25 4.63 10.25 1.12 0.44 7.88 0.88 0.63 1.38
10SM12083 REG (19.03) (13.11) (76.20) (38.10) (15.75) (76.20) (57.15) (117.48) (260.35) (28.45) (11.18) (200.03) (22.35) (16.00) (35.05)
10SM16073 VEE 1 0.688 4.12 2.06 0.63 3.75 2.81 5.88 10.25 1.62 0.56 9.75 1.25 1.13 1.75
10SM16083 REG (25.40) (17.48) (104.65) (52.32) (16.00) (95.25) (71.37) (149.35) (260.35) (41.15) (14.22) (247.89) (31.75) (28.70) (44.45)
G - Packing gland mounting hole drill size * H Dimension is with stem in closed position. For prompt service, Parker
G1 - Bracket mounting hole size All dimensions for reference only and subject to change. Autoclave Engineers stock
Panel mounting drill size: 0.22 all valves. select products.
Consult factory.
Figure 2 Figure 3
F F
M M G1 M M
G G
G1 H N
N
H D D1
D
E E
C
C
B B
A A
2-Way Angle 3-Way / 2 on Pressure
4 All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold.
Outside Dimensions - inches (mm) Block
Catalog Stem Diameter Orifice Thick- Valve
Number Type Tube Diameter A B C D D1 E F G G1 H* M N ness Pattern
3-Way / 1 on Pressure
20SM4074 VEE 1/4 0.125 2.00 1.00 0.38 1.19 2.44 3.00 0.75 0.22 4.81 0.62 0.38 0.75
20SM4084 REG (6.35) (3.18) (50.80) (25.40) (9.65) (30.23) (61.90) (76.20) (19.05) (5.59) (122.25) (15.75) (9.65) (19.05)
20SM6074 VEE 3/8 0.219 2.00 1.00 0.47 1.19 2.44 3.00 0.75 0.22 4.81 0.62 0.38 0.75
20SM6084 REG (9.53) (5.56) (50.80) (25.40) (11.94) (30.23) (61.90) (76.20) (19.05) (5.59) (122.25) (15.75) (9.65) (19.05)
20SM9074 VEE 9/16 0.312 2.50 1.25 0.53 1.75 3.38 4.00 1.00 0.34 6.31 0.69 0.50 1.00
20SM9084 REG (14.29) (7.92) (63.50) (31.75) (13.46) (44.45) (85.85) (101.60) (25.40) (8.64) (160.56) (17.53) (12.70) (25.40)
20SM12074 VEE 3/4 0.438 3.00 1.50 0.62 2.25 4.25 10.25 1.12 0.44 7.50 0.88 0.63 1.38
20SM12084 REG See
(19.05) (11.13) (76.20) (38.10) (15.75) (57.15) (107.95) (260.35) (28.45) (11.18) (190.50) (22.35) (16.00) (35.05)
Figure 4
20SM16074 VEE 1 0.562 4.12 2.06 0.63 2.81 5.12 10.25 1.62 0.56 9.09 1.25 1.13 1.75
20SM16084 REG (25.40) (14.27) (104.65) (52.32) (16.00) (71.37) (130.05) (260.35) (41.15) (14.22) (231.13) (31.75) (28.70) (44.4 5)
10SM9074 VEE 9/16 0.359 2.50 1.25 0.53 1.75 3.38 4.00 1.00 0.34 6.31 0.69 0.50 1.00
10SM9084 REG (14.29) (9.12) (63.50) (31.75) (13.46) (44.45) (85.85) (101.60) (25.40) (8.64) (160.56) (17.53) (12.70) (25.40)
10SM12074 VEE 3/4 0.516 3.00 1.50 0.62 2.25 4.25 10.25 1.12 0.44 7.50 0.88 0.63 1.38
10SM12084 REG (19.03) (13.11) (76.20) (38.10) (15.75) (57.15) (107.95) (260.35) (28.45) (11.18) (190.50) (22.35) (16.00) (35.05)
10SM16074 VEE 1 0.688 4.12 2.06 0.63 2.81 5.12 10.25 1.62 0.56 9.09 1.25 1.13 1.75
10SM16084 REG (25.40) (17.48) (104.65) (52.32) (16.00) (71.37) (130.05) (260.35) (41.15) (14.22) (231.13) (31.75) (28.70) (44.45)
G - Packing gland mounting hole drill size * H Dimension is with stem in closed position. For prompt service, Parker
G1 - Bracket mounting hole size All dimensions for reference only and subject to change. Autoclave Engineers stock
Panel mounting drill size: 0.22 all valves. select products.
Consult factory.
Figure 4 Figure 5
F F
G1 G1 M M
M M G
N
H N G
H D
D D E
E C
D1
C
C
B B
A A
3-Way / 1 on Pressure 2-Way Angle / Replaceable Seat
All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold. 5
Outside Dimensions - inches (mm) Block
Catalog Stem Diameter Orifice Thick- Valve
Number Type Tube Diameter A B C D D1 E F G G1 H* M N ness Pattern
G - Packing gland mounting hole drill size * H Dimension is with stem in closed position. For prompt service, Parker
G1 - Bracket mounting hole size All dimensions for reference only and subject to change. Autoclave Engineers stock
Panel mounting drill size: 0.22 all valves. select products.
Consult factory.
Figure 6
F
G1
M M
G
H N
D1
D
E
D1
C
B
A
6 All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold.
All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold. 7
WARNING
FAILURE, IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS AND/OR SYSTEMS DESCRIBED HEREIN OR RELATED ITEMS CAN CAUSE DEATH, PERSONAL INJURY
AND PROPERTY DAMAGE.
This document and other information from Parker Hannifin Corporation, its subsidiaries and authorized distributors provide product and/or system options for further investiga-
tion by users having technical expertise. It is important that you analyze all aspects of your application and review the information concerning the product or system in the current
product catalog. Due to the variety of operating conditions and applications for these products or systems, the user, through its own analysis and testing, is solely responsible
for making the final selection of the products and systems and assuring that all performance, safety and warning requirements of the application are met. The products described
herein, including without limitation, product features, specifications, designs, availability and pricing, are subject to change by Parker Hannifin Corporation and its subsidiaries at
any time without notice.
Offer of Sale
The items described in this document are available for sale by Parker Hannifin Corporation, its subsidiaries or its authorized distributors. Any sale contract entered by Parker will be
governed by the provisions stated in Parker's standard terms and conditions of sale (copy available upon request).
2013 Parker Hannifin Corporation | Autoclave Engineers is a registered trademark of the Parker Hannifin Corporation 02-0112SE January2013
Instrumentation Products Division Parker Hannifin Manufacturing Ltd. Caution! Parker Autoclave Engineers Valves, Fittings and Tools are
Autoclave Engineers Operation Instrumentation Products Division, Europe not designed to work with common commercial instrument tubing
8325 Hessinger Drive Industrial Estate Whitemill and will only work with tubing built to Parker Autoclave Engineers
Erie, Pennsylvania 16509-4679 USA Wexford, Republic of Ireland AES Specifications. Failure to do so will void warranty.
QS Series
Pressures to 15,000 psi (1034 bar)
www.autoclave.com 1
Needle Valves - QS Series
Pressures to 15,000 psi (1034 bar)
Tube Pressure
Outside Rating
Diameter Orifice psi (bar)
Size Connection Size Rated @ Room
Inches Type Inches (mm) Cv* Temperature**
Notes:
* CV values shown are for 2-way straight valve pattern. For 2-way
angle patterns, increase CV value 50%. (Based on water)
LOW FRICTION
STAINLESS STEEL
HANDLE 7
ALUMINUM ONE PIECE NON-ROTATING
BRONZE PACKING STEM
GLAND
6
LOCKING DEVICE
Regulating Stem
Number of turns open
5
ANTI-EXTRUSION
BACK-UP RINGS
ADJUSTABLE PACKING
4
BELOW THREADS
COLD WORKED
TYPE 316 SS
BODY IN FIVE
3
PATTERNS
(See Note)
2
MEDIUM
PRESSURE
Vee Stem
1
COMPRESSION
SLEEVE
CHOICE OF VEE CONNECTIONS
METAL-TO-METAL
OR REGULATING SEATING
STEM TIP
0
(Note: 1 valves are 2507 Super Duplex)
10 20 30 40 50 60 70 80 90 100
% of rated Cv
To ensure proper fit use Parker Autoclave Engineers tubing
Ordering Procedure
For complete information on available stem types, optional connections and additional valve options, see Needle Valve Options section or contact
your Sales Representative. QS Series valves are furnished complete with connection components, unless otherwise specified.
15QS 4 07 1 XX
Valve Outside Diameter Stem/Seat Body Options
Series Tube Size Type Pattern
TG - PTFE Glass Plating
15QS 4-1/4 07 - non-rotating 1 - two-way straight
Vee stem (on-off service) GY - Graphite Yarn
6-3/8 2 - two-way angle
Packing
9-9/16 08 - non-rotating 3 - three-way, two on pressure
12-3/4 regulating stem (tapered tip See valve options
4 - three-way, one on pressure for ratings
16-1 for regulating and shutoff)
5 - three-way, two stem
87 - Vee stem with replaceable seat
manifold valve
88 - Regulating stem with replaceable seat
2
Valve Options Valve Maintenance
Extreme Temperatures Repair Kits: add R to the front of valve catalog
Standard Parker Autoclave Engineers valves with PTFE packing may number for proper repair kit.
be operated to 450F (232C). High temperature packing and/or (Example: R15QS4071)
extended stuffing box are available for service from -100F (-73C) Valve Bodies: Valve bodies are available. Order using the eight (8)
to 650F (343C) by adding the following suffixes to catalog order digit part number found on the valve drawing or
number. contact your Sales Representative for information.
TG standard valve with PTFE glass packing to 600F (316C).
GY standard valve with graphite braided yarn packing to 650F (343C). Consult your Parker Autoclave Engineers representative for pricing on repair
B standard valve with cryogenic trim materials and PTFE packing to kits and valve bodies.
-100F (-73C).
2-Way Straight
15QS4071 VEE 1/4 0.125 2.00 1.00 0.38 1.62 1.19 2.00 3.00 0.75 0.22 4.69 0.62 0.38 0.75
15QS4081 REG (6.35) (3.18) (50.80) (25.40) (9.53) (41.15) (30.23) (50.80) (76.20) (19.05) (5.59) (119.13) (15.75) (9.65) (19.05)
15QS6071 VEE 3/8 0.219 2.00 1.00 0.47 1.62 1.19 2.00 3.00 0.75 0.22 4.63 0.62 0.38 0.81
15QS6081 REG (9.53) (5.56) (50.80) (25.40) (11.94) (41.15) (30.23) (50.80) (76.20) (19.05) (5.59) (117.60) (15.75) (9.65) (20.57)
15QS9071 VEE 9/16 0.359 3.00 1.50 0.53 2.38 1.75 3.00 4.00 1.00 0.34 6.05 0.69 0.50 1.25 See
15QS9081 REG (14.29) (9.12) (76.20) (38.10) (13.46) (60.45) (44.45) (76.20) (101.60) (25.40) (8.64) (153.67) (17.53) (12.70) (31.75) Figure 1
15QS12071 VEE 3/4 0.516 4.12 2.06 0.62 3.00 2.25 3.88 10.25 1.12 0.44 7.13 0.88 0.63 1.50
15QS12081 REG (19.05) (13.11) (104.65) (52.32) (15.75) (76.20) (57.15) (98.43) (260.35) (28.45) (11.18) (180.98) (22.35) (16.00) (38.10)
15QS16071 VEE 1 0.688 4.75 2.38 1.19 3.75 2.63 4.75 10.25 1.12 0.44 8.00 0.88 0.63 2.00
15QS16081 REG (25.40) (17.48) (120.65) (60.33) (30.18) (95.25) (66.68) (120.65) (260.35) (28.45) (11.18) (203.20) (22.35) (16.00) (50.80)
Note: 1 valve bodies are 2507 Super Duplex
2-Way Angle
15QS4072 VEE 1/4 0.125 2.00 1.00 0.38 1.19 2.44 3.00 0.75 0.22 4.81 0.62 0.38 0.75
15QS4082 REG (6.35) (3.18) (50.80) (25.40) (9.53) (30.23) (61.98) (76.20) (19.05) (5.59) (122.17) (15.75) (9.65) (19.05)
15QS6072 VEE 3/8 0.219 2.00 1.00 0.47 1.20 2.56 3.00 0.75 0.22 4.93 0.62 0.38 0.81
15QS6082 REG (9.53) (5.56) (50.80) (25.40) (11.94) (30.48) (65.02) (76.20) (19.05) (5.59) (125.22) (15.75) (9.65) (20.62)
15QS9072 VEE 9/16 0.359 3.00 1.50 0.53 1.69 3.50 4.00 1.00 0.36 6.55 0.69 0.50 1.25 See
15QS9082 REG (14.29) (9.12) (76.20) (38.10) (13.46) (42.88) (88.90) (101.60) (25.40) (9.14) (166.37) (17.53) (12.70) (31.75) Figure 2
15QS12072 VEE 3/4 0.516 4.12 2.06 0.62 2.19 4.63 10.25 1.12 0.44 7.88 0.88 0.63 1.50
15QS12082 REG (19.05) (13.11) (104.65) (52.32) (15.75) (55.58) (117.48) (260.35) (28.45) (11.18) (200.15) (22.35) (16.00) (38.10)
15QS16072 VEE 1 0.688 4.75 2.38 1.19 3.75 5.38 10.25 1.12 0.44 8.63 0.88 0.63 2.00
15QS16082 REG (25.40) (17.48) (120.65) (60.33) (30.18) (95.25) (136.53) (260.35) (28.45) (11.18) (219.25) (22.35) (16.00) (50.80)
Note: 1 valve bodies are 2507 Super Duplex
G - Packing gland mounting hole drill size * H Dimension is with stem in closed position. For prompt service, Parker Autoclave Engineers stocks
G - Bracket mounting hole size **1/8" straight and 3-Way/2 on pressure valves have offset select products. Consult factory.
1
Panel mounting drill size: 0.22 all valves. tube connections All dimensions for reference only and subject to change.
Figure 1 Figure 2
F F
G1 M M M M G
H N G G1
H
N
D1 D
D
E
E
C C
B
A B
A
2-Way Straight 2-Way Angle
3
WARNING
FAILURE, IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS AND/OR SYSTEMS DESCRIBED HEREIN OR RELATED ITEMS CAN CAUSE DEATH, PERSONAL INJURY AND PROPERTY DAMAGE.
This document and other information from Parker Hannifin Corporation, its subsidiaries and authorized distributors provide product and/or system options for further investigation by users having technical
expertise. It is important that you analyze all aspects of your application and review the information concerning the product or system in the current product catalog. Due to the variety of operating conditions
and applications for these products or systems, the user, through its own analysis and testing, is solely responsible for making the final selection of the products and systems and assuring that all performance,
safety and warning requirements of the application are met. The products described herein, including without limitation, product features, specifications, designs, availability and pricing, are subject to change by
Parker Hannifin Corporation and its subsidiaries at any time without notice.
Offer of Sale
The items described in this document are available for sale by Parker Hannifin Corporation, its subsidiaries or its authorized distributors. Any sale contract entered by Parker will be governed by the provisions
stated in Parker's standard terms and conditions of sale (copy available upon request).
2013 Parker Hannifin Corporation | Autoclave Engineers is a registered trademark of the Parker Hannifin Corporation 02-1246BE January2013
Instrumentation Products Division Parker Hannifin Manufacturing Ltd. Caution! Parker Autoclave Engineers Valves, Fittings and Tools are
not designed to work with common commercial instrument tubing
Autoclave Engineers Operation Instrumentation Products Division, Europe
and will only work with tubing built to Parker Autoclave Engineers
8325 Hessinger Drive Industrial Estate Whitemill AES Specifications. Failure to do so will void warranty.
Erie, Pennsylvania 16509-4679 USA Wexford, Republic of Ireland
PH: 814-860-5700 FAX: 814-860-5811 PH: 353 53 914 1566
www.autoclave.com FAX: 353 53 914 1582 ISO-9001 Certified
Needle Valves
High Pressure
30SC, 43SC, 30VM, 40VM, 60VM,
100VM & 150V Series
Pressures to 150,000 psi (10342 bar)
www.autoclave.com
Needle Valves - High Pressure
High Pressure Valve Features
2 All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold.
Needle Valves - SC Series
Pressures to 43,000 psi (2965 bar)
Tube Pressure
Outside Rating
Diameter Orifice psi (bar)
Size Connection Size Rated @ Room
Inches Type Inches (mm) Cv* Temperature**
Series 30SC
1 F1000C43 .438 (11.12) 2.6 30,000 (2068)
Series 43SC
1 F1000C43 .438 (11.12) 2.6 43,000 (2965)
Notes:
* CV values shown are for 2-way straight valve pattern. For 2-way
angle patterns, increase CV value 50%.
LOW FRICTION
6
ALUMINUM
Number of turns open
BRONZE PACKING
GLAND
LOCKING DEVICE 5
Regulating Stem
4
ANTI-EXTRUSION
NON-ROTATING
BACK-UP RINGS
STEM
ADJUSTABLE PACKING
3
BELOW THREADS
COLD WORKED
TYPE 316 SS
BODY IN TWO
PATTERNS
2
Vee Stem
1
HIGH PRESSURE
CONED AND
THREADED
CONNECTIONS
CHOICE OF VEE METAL-TO-METAL 0
OR REGULATING
STEM TIP
SEATING 10 20 30 40 50 60 70 80 90 100
% of rated Cv
To ensure proper fit use Autoclave tubing
Ordering Procedure
For complete information on available stem types, optional connections and additional valve options, see Needle Valve Options section or contact
your Sales Representative. The 30SC Series valves are furnished complete with connection components, unless otherwise specified.
30SC 16 07 1 XX
Valve Outside Diameter Stem/Seat Body Options
Series Tube Size Type Pattern
For extreme
30SC 16-1 07 - non-rotating 1 - two-way straight
temperature and
43SC Vee stem (on-off service) 2 - two-way angle other options,
08 - non-rotating
see Valve Options.
regulating stem (tapered tip
for regulating and shutoff)
87 - Vee stem with replaceable
seat
88 - Regulating stem with
replaceable seat
All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold. 3
Valve Options Valve Maintenance
Extreme Temperatures Repair Kits: add R to the front of valve catalog
Standard Parker Autoclave Engineers valves with PTFE packing may number for proper repair kit.
be operated from 0F (-17.8C) to 450F (232C). High temperature (Example: R30SC16071)
packing is available for service from -423F (-252C) to 1200F Valve Bodies: Valve bodies are available. Order using the eight (8)
(649C) by adding the following suffixes to catalog order number. digit part number found in the valve drawing or
TG - standard valve with PTFE glass packing to 600F (316C). contact your Sales Representative for information.
GY - standard valve with graphite braided yarn packing to 800F (427C). Consult your Parker Autoclave Engineers representative for pricing on repair
8,000 psi (569 bar) max. kits and valve bodies. Refer to the Tools, Installation, Operation and
HT - extended stuffing box valve with graphite braided yarn packing to 1200F (649C). Maintenance section for proper maintenance procedures.
B - standard valve with cryogenic trim material and PTFE packing to -100F (-73C).
LT - extended stuffing box valve with PTFE packing & Cryogenic trim materials to
-423F (-252C).
K - anti-vibration collet and gland assembly.
2-Way Straight
30SC16071 VEE 1 0.438 4.13 2.06 0.72 3.50 2.75 4.44 10.25 1.62 0.56 8.42 1.25 1.12 1.75
30SC16081 REG (25.40) (11.12) (104.90) (52.32) (18.28) (88.90) (69.85) (112.77) (260.35) (41.14) (14.22) (213.86) (31.75) (28.44) (44.45) See
43SC16071 VEE 1 0.438 4.88 2.44 0.72 3.50 2.75 4.44 10.25 1.62 0.56 8.42 1.25 1.12 2.25 Figure 1
43SC16081 REG (25.40) (11.12) (123.96) (61.96) (18.28) (88.90) (69.85) (112.77) (260.35) (41.14) (14.22) (213.86) (31.75) (28.44) (57.15)
2-Way Angle
30SC16072 VEE 1 0.438 4.13 2.06 0.72 2.75 5.12 10.25 1.62 0.56 9.35 1.25 1.12 1.75
30SC16082 REG (25.40) (11.12) (104.90) (52.32) (18.28) (69.85) (130.04) (260.35) (41.14) (14.22) (237.49) (31.75) (28.44) (44.45) See
43SC16072 VEE 1 0.438 4.88 2.44 0.72 2.75 5.12 10.25 1.62 0.56 9.35 1.25 1.12 2.25 Figure 2
43SC16082 REG (25.40) (11.12) (123.96) (61.96) (18.28) (69.85) (130.04) (260.35) (41.14) (14.22) (237.49) (31.75) (28.44) (57.15)
G - Packing gland mounting hole drill size * H Dimension is with stem in closed position. For prompt service, Parker
G1 - Bracket mounting hole size All dimensions for reference only and subject to change. Autoclave Engineers stock
Panel mounting drill size: 0.22 all valves. select products.
Consult factory.
G1 M M G1 M M
N G N G
H D H D
E
E C
C
D1
B A
B
A
4 All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold.
Needle Valves - 30VM Series
Pressures to 30,000 psi (2068 bar)
Tube Pressure
Outside Rating
Diameter Orifice psi (bar)
Size Connection Size Rated @ Room
Inches Type Inches (mm) Cv* Temperature**
Notes:
* CV values shown are for 2-way straight valve pattern. For 2-way
angle patterns, increase CV value 50%.
PATTERNS
LOCKING DEVICE 5
NON-ROTATING
STEM ADJUSTABLE PACKING Regulating Stem
BELOW THREADS
ANTI-EXTRUSION
4
BACK-UP RINGS
1
Vee Stem
CHOICE OF VEE OR HIGH PRESSURE
REGULATING STEM TIP CONED-AND-THREADED 0
METAL-TO-METAL SEATING CONNECTIONS
10 20 30 40 50 60 70 80 90 100
% of rated Cv
To ensure proper fit use Autoclave tubing
Ordering Procedure
For complete information on available stem types, optional connections and additional valve options, see Needle Valve Options section or contact
your Sales Representative. The 30VM Series valves are furnished complete with connection components, unless otherwise specified.
30VM 4 07 1 XX
Valve Outside Diameter Stem/Seat Body Options
Series Tube Size Type Pattern
For extreme
4-1/4 07 - non-rotating 1 - two-way straight
temperature and other
6-3/8 Vee stem (on-off service) 2 - two-way angle options, see Valve
9-9/16 08 - non-rotating 3 - three-way, two on pressure Options.
regulating stem (tapered tip
4 - three-way, one on pressure
for regulating and shutoff)
5 - three-way, two-stem
87 - Vee stem with replaceable
manifold valve
seat
88 - Regulating stem with
replaceable seat
All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold. 5
Valve Options Valve Maintenance
Extreme Temperatures Repair Kits: add R to the front of valve catalog
Standard Parker Autoclave Engineers valves with PTFE packing may number for proper repair kit.
be operated from 0F (-17.8C) to 450F (232C). High temperature (Example: R30VM4071)
packing is available for service from -423F (-252C) to 1200F Valve Bodies: Valve bodies are available. Order using the eight (8)
(644C) by adding the following suffixes to catalog order number. digit part number found in the valve drawing or
TG - standard valve with PTFE glass packing to 600F (316C). contact your Sales Representative for information.
GY - standard valve with graphite braided yarn packing to 800F (427C). Consult your Parker Autoclave Engineers representative for pricing on repair
HT - extended stuffing box valve with graphite braided yarn packing to 1200F (649C). kits and valve bodies. Refer to the Tools, Installation, Operation and Mainte-
B - standard valve with cryogenic trim material and PTFE packing to -100F (-73C). nance section for proper maintenance procedures.
LT - extended stuffing box valve with PTFE packing & Cryogenic trim materials to
-423F (-252C).
K - anti-vibration collet and gland assembly.
2-Way Straight
30VM4071 VEE 1/4 0.094 2.00 1.00 0.50 1.50 1.12 2.00 3.00 1.00 0.22 4.62 0.69 0.38 1.00
30VM4081 REG (6.35) (2.39) (50.80) (25.40) (12.70) (38.10) (28.45) (50.80) (76.20) (25.40) (5.59) (117.35) (17.53) (9.65) (25.40)
30VM6071 VEE 3/8 0.125 2.00 1.00 0.53 1.50 1.12 2.00 3.00 1.00 0.22 4.68 0.69 0.38 1.00 See
30VM6081 REG (9.53) (3.18) (50.80) (25.40) (13.46) (38.10) (28.45) (50.80) (76.20) (25.40) (5.59) (118.87) (17.53) (9.65) (25.40) Figure 1
30VM9071 VEE 9/16 0.125 2.62 1.31 0.81 1.56 1.12 2.44 3.00 1.00 0.28 5.06 0.69 0.38 1.50
30VM9081 REG (14.29) (3.18) (66.55) (33.27) (20.57) (39.62) (28.45) (61.98) (76.20) (25.40) (7.11) (128.52) (17.53) (9.65) (38.10)
2-Way Angle
30VM4072 VEE 1/4 0.094 2.00 1.00 0.50 1.12 2.00 3.00 1.00 0.22 4.62 0.69 0.38 1.00
30VM4082 REG (6.35) (2.39) (50.80) (25.40) (12.70) (28.45) (50.80) (76.20) (25.40) (5.59) (117.35) (17.53) (9.65) (25.40)
30VM6072 VEE 3/8 0.125 2.00 1.00 0.53 1.12 2.12 3.00 1.00 0.22 4.74 0.69 0.38 1.00 See
30VM6082 REG (9.53) (3.18) (50.80) (25.40) (13.46) (28.45) (53.85) (76.20) (25.40) (5.59) (120.40) (17.53) (9.65) (25.40) Figure 2
30VM9072 VEE 9/16 0.125 2.62 1.31 0.81 1.12 2.44 3.00 1.00 0.28 5.06 0.69 0.38 1.50
30VM9082 REG (14.29) (3.18) (66.55) (33.27) (20.57) (28.45) (61.98) (76.20) (25.40) (7.11) (128.52) (17.53) (9.65) (38.10)
3-Way / 2 on Pressure
30VM4073 VEE 1/4 0.094 2.00 1.00 0.50 1.50 1.12 2.12 3.00 1.00 0.22 4.74 0.69 0.38 1.00
30VM4083 REG (6.35) (2.39) (50.80) (25.40) (12.70) (38.10) (28.45) (53.85) (76.20) (25.40) (5.59) (120.40) (17.53) (9.65) (25.40)
30VM6073 VEE 3/8 0.125 2.00 1.00 0.53 1.50 1.12 2.50 3.00 1.00 0.22 5.12 0.69 0.38 1.00 See
30VM6083 REG (9.53) (3.18) (50.80) (25.40) (13.46) (38.10) (28.45) (63.50) (76.20) (25.40) (5.59) (130.05) (17.53) (9.65) (25.40) Figure 3
30VM9073 VEE 9/16 0.125 2.62 1.31 0.81 1.56 1.12 2.88 3.00 1.00 0.28 5.49 0.69 0.38 1.50
30VM9083 REG (14.29) (3.18) (66.55) (33.27) (20.57) (39.62) (28.45) (73.15) (76.20) (25.40) (7.11) (139.45) (17.53) (9.65) (38.10)
G - Packing gland mounting hole drill size * H Dimension is with stem in closed position. For prompt service, Parker
G1 - Bracket mounting hole size All dimensions for reference only and subject to change. Autoclave Engineers stock
Panel mounting drill size: 0.22 all valves. select products.Consult
factory.
G1 M G1 M G1 M M
M M
H N G H N G
H N G
D D1
D1 D
D E
E
E C
C C
B B
A B A
A
2-Way Straight 2-Way Angle 3-Way / 2 on Pressure
6 All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold.
Dimensions - inches (mm) Block
Catalog Outside
Stem Orifice Thick- Valve
Number Diameter
Type Diameter
Tube A B C D D1 E F G G1 H* M N ness Pattern
3-Way / 1 on Pressure
30VM4074 VEE 1/4 0.094 2.00 1.00 0.50 1.12 2.00 3.00 1.00 0.22 4.62 0.69 0.38 1.00
30VM4084 REG (6.35) (2.39) (50.80) (25.40) (12.70) (28.45) (50.80) (76.20) (25.40) (5.59) (117.35) (17.53) (9.65) (25.40)
30VM6074 VEE 3/8 0.125 2.00 1.00 0.53 1.12 2.12 3.00 1.00 0.22 4.74 0.69 0.38 1.00 See
30VM6084 REG (9.53) (3.18) (50.80) (25.40) (13.46) (28.45) (53.85) (76.20) (25.40) (5.59) (120.40) (17.53) (9.65) (25.40) Figure 4
30VM9074 VEE 9/16 0.125 2.62 1.31 0.81 1.12 2.44 3.00 1.00 0.28 5.12 0.69 0.38 1.50
30VM9084 REG (14.29) (3.18) (66.55) (33.27) (20.57) (28.45) (61.98) (76.20) (25.40) (7.11) (130.05) (17.53) (9.65) (38.10)
G - Packing gland mounting hole drill size * H Dimension is with stem in closed position. For prompt service, Parker
G1 - Bracket mounting hole size All dimensions for reference only and subject to change. Autoclave engineers stock
Panel mounting drill size: 0.22 all valves. select products.
Consult factory.
G1
G1 M M M M
N G
N G H
D1
D D
H
E
E
C
D1
D1 C
B
A
B
A
3-Way / 1 on Pressure 2-Way Angle / Replacable Seat 3-Way / 2-Stem Manifold
All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold. 7
Needle Valves - 40VM Series
Pressures to 40,000 psi (2760 bar)
Tube Pressure
Outside Rating
Diameter Orifice psi (bar)
Size Connection Size Rated @ Room
Inches Type Inches (mm) Cv* Temperature**
Notes:
* CV values shown are for 2-way straight valve pattern. For 2-way
angle patterns, increase CV value 50%.
ALUMINUM BRONZE
POWDER COATED
STAINLESS STEEL
6
PACKING GLAND HANDLE
Number of turns open
1
Vee Stem
HIGH PRESSURE
CONED-AND-THREADED
CONNECTIONS 0
CHOICE OF VEE OR
REGULATING STEM TIP
10 20 30 40 50 60 70 80 90 100
METAL-TO-METAL SEATING
% of rated Cv
Ordering Procedure
For complete information on available stem types, optional connections and additional valve options, see Needle Valve Options Section or contact
your Sales Representative. The 40VM Series valves are furnished complete with connection components, unless otherwise specified.
40VM 9 07 1 XX
Valve Outside Diameter Stem/Seat Body Options
Series Tube Size Type Pattern
For extreme
9-9/16 07 - non-rotating 1 - two-way straight
temperature and other
Vee stem (on-off service) 2 - two-way angle options, see Valve
08 - non-rotating 5 - three-way, two-stem Options.
regulating stem (tapered tip manifold valve
for regulating and shutoff)
8 All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold.
Valve Options Valve Maintenance
Extreme Temperatures Repair Kits: add R to the front of valve catalog
Standard Parker Autoclave Engineers valves with PTFE packing may number for proper repair kit.
be operated from 0F (-17.8C) to 450F (232C). High temperature (Example: R40VM9071)
packing is available for service from -423F (-252C) to 1200F Valve Bodies: Valve bodies are available. Order using the eight (8)
(649C) by adding the following suffixes to catalog order number. digit part number found in the valve drawing or
contact your Sales Representative for information.
TG - standard valve with PTFE glass packing to 600F (316C). See note below.
Consult your Parker Autoclave Engineers representative for pricing on repair
GY - standard valve with graphite braided yarn packing to 800F (427C).
kits and valve bodies. Refer to the Tools, Installation, Operation and
HT - extended stuffing box valve with graphite braided yarn packing to 1200F (649C). Maintenance section for proper maintenance procedures.
B - standard valve with cryogenic trim material and PTFE packing to -100F (-73C).
LT - extended stuffing box valve with PTFE packing & Cryogenic trim materials to
-423F (-252C).
K - anti-vibration collet and gland assembly.
Note: 40VM and 60VM valves supplied with Peak/PTFE Glass/Peek
2-Way Straight
40VM9071 VEE 9/16 0.109 2.62 1.31 0.72 1.75 1.31 2.50 3.00 1.00 0.28 5.06 0.69 0.38 1.50 See
40VM9081 REG (14.3) (2.77) (66.55) (33.27) (18.29) (44.45) (33.27) (63.50) (76.20) (25.40) (7.11) (128.52) (17.53) (9.65) (38.10) Figure 1
2-Way Angle
40VM9072 VEE 9/16 0.109 2.62 1.31 0.72 1.31 2.81 3.00 1.00 0.28 5.37 0.69 0.38 1.50 See
40VM9082 REG (14.3) (2.77) (66.55) (33.27) (18.29) (33.27) (71.37) (76.20) (25.40) (7.11) (136.40) (17.53) (9.65) (38.10) Figure 2
G - Packing gland mounting hole drill size * H Dimension is with stem in closed position. For prompt service, Parker
G1 - Bracket mounting hole size All dimensions for reference only and subject to change. Autoclave Engineers stock
Panel mounting drill size: 0.22 all valves. select products.
Consult factory.
2-Way Straight 2-Way Angle 3-Way / 2 Stem Manifold 2-Way Angle / Replaceable Seat
All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold. 9
Needle Valves - 60VM Series
Pressures to 60,000 psi (4137 bar)
Tube Pressure
Outside Rating
Diameter Orifice psi (bar)
Size Connection Size Rated @ Room
Inches Type Inches (mm) Cv* Temperature**
Notes:
* CV values shown are for 2-way straight valve pattern. For 2-way
angle patterns, increase CV value 50%.
LOCKING DEVICE
NON-ROTATING 5
STEM
ADJUSTABLE PACKING 4
BELOW THREADS
ANTI-EXTRUSION
BACK-UP RINGS Regulating Stem
3
HIGH PRESSURE 1
CONED-AND-THREADED
CHOICE OF VEE OR
CONNECTIONS Vee Stem
REGULATING STEM TIP
METAL-TO-METAL SEATING 0
10 20 30 40 50 60 70 80 90 100
Ordering Procedure
For complete information on available stem types, optional connections and additional valve options, see Needle Valve Options section or contact
your Sales Representative. The 60VM Series valves are furnished complete with connection components, unless otherwise specified.
60VM 4 07 1 XX
Valve Outside Diameter Stem/Seat Body Options
Series Tube Size Type Pattern
For extreme
4-1/4 07 - non-rotating 1 - two-way straight
temperature and other
6-3/8 Vee stem (on-off service) 2 - two-way angle options, see Valve
9-9/16 08 - non-rotating 3 - three-way, two on pressure Options.
regulating stem (tapered tip
4 - three-way, one on pressure
for regulating and shutoff)
5 - three-way, two-stem
87 - Vee stem with replaceable
manifold valve
seat
88 - Regulating stem with
replaceable seat
10 All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold.
Valve Options Valve Maintenance
Extreme Temperatures Repair Kits: add R to the front of valve catalog
Standard Parker Autoclave Engineers valves with PTFE packing may number for proper repair kit.
be operated from 0F (-17.8C) to 450F (232C). High temperature (Example: R60VM4071)
packing is available for service from -423F (-252C) to 1200F Valve Bodies: Valve bodies are available. Order using the eight (8)
(649C) by adding the following suffixes to catalog order number. digit part number found in the valve drawing or
contact your Sales Representative for information.
TG - standard valve with PTFE glass packing to 600F (316C). See note below.
Consult your Parker Autoclave Engineers representative for pricing on repair
GY - standard valve with graphite braided yarn packing to 800F (427C).
kits and valve bodies. Refer to the Tools, Installation, Operation and
HT - extended stuffing box valve with graphite braided yarn packing to 1200F (649C). Maintenance section for proper maintenance procedures.
B - standard valve with cryogenic trim material and PTFE packing to -100F (-73C).
LT - extended stuffing box valve with PTFE packing & Cryogenic trim materials to
-423F (-252C).
K - anti-vibration collet and gland assembly.
Note: 40VM and 60VM valves supplied with Peak/PTFE Glass/Peek
2-Way Straight
60VM4071 VEE 1/4 0.062 2.00 1.00 0.50 1.69 1.31 2.12 3.00 1.00 0.22 4.75 0.69 0.38 1.00
60VM4081 REG (6.35) (1.57) (50.80) (25.40) (12.70) (42.93) (33.27) (53.85) (76.20) (25.40) (5.59) (120.65) (17.53) (9.65) (25.40)
60VM6071 VEE 3/8 0.062 2.00 1.00 0.53 1.69 1.31 2.25 3.00 1.00 0.22 4.87 0.69 0.38 1.00 See
60VM6081 REG (9.53) (1.57) (50.80) (25.40) (13.46) (42.93) (33.27) (57.15) (76.20) (25.40) (5.59) (123.70) (17.53) (9.65) (25.40) Figure 1
60VM9071 VEE 9/16 0.078 2.62 1.31 0.72 1.75 1.31 2.50 3.00 1.00 0.28 5.13 0.69 0.38 1.50
60VM9081 REG (14.29) (1.98) (66.55) (33.27) (18.29) (45.45) (33.27) (63.50) (76.20) (25.40) (7.11) (130.30) (17.53) (9.65) (38.10)
2-Way Angle
60VM4072 VEE 1/4 0.062 2.00 1.00 0.50 1.31 2.38 3.00 1.00 0.22 5.00 0.69 0.38 1.00
60VM4082 REG (6.35) (1.57) (50.80) (25.40) (12.70) (33.27) (60.45) (76.20) (25.40) (5.59) (127.00) (17.53) (9.65) (25.40)
60VM6072 VEE 3/8 0.062 2.00 1.00 0.53 1.31 2.62 3.00 1.00 0.22 5.25 0.69 0.38 1.00 See
Figure 2
60VM6082 REG (9.53) (1.57) (50.80) (25.40) (13.46) (33.27) (66.55) (76.20) (25.40) (5.59) (133.35) (17.53) (9.65) (25.40)
60VM9072 VEE 9/16 0.078 2.62 1.31 0.72 1.31 2.81 3.00 1.00 0.28 5.44 0.69 0.38 1.50
60VM9082 REG (14.29) (1.98) (66.55) (33.27) (18.29) (33.27) (71.37) (76.20) (25.40) (7.11) (138.18) (17.53) (9.65) (38.10)
3-Way / 2 on Pressure
60VM4073 VEE 1/4 0.062 2.00 1.00 0.50 1.69 1.31 2.38 3.00 1.00 0.22 4.75 0.69 0.38 1.00
60VM4083 REG (6.35) (1.57) (50.80) (25.40) (12.70) (42.93) (33.27) (60.45) (76.20) (25.40) (5.59) (120.65) (17.53) (9.65) (25.40)
60VM6073 VEE 3/8 0.062 2.00 1.00 0.53 1.69 1.31 2.75 3.00 1.00 0.22 4.87 0.69 0.38 1.00 See
60VM6083 REG (9.53) (1.57) (50.80) (25.40) (13.46) (42.93) (33.27) (68.86) (76.20) (25.40) (5.59) (123.70) (17.53) (9.65) (25.40) Figure 3
60VM9073 VEE 9/16 0.078 2.62 1.31 0.72 1.75 1.31 3.03 3.00 1.00 0.28 5.13 0.69 0.38 1.50
60VM9083 REG (14.29) (1.98) (66.55) (33.27) (18.29) (45.45) (33.27) (76.96) (76.20) (25.40) (7.11) (130.30) (17.53) (9.65) (38.10)
G - Packing gland mounting hole drill size * H Dimension is with stem in closed position. For prompt service, Parker
G1 - Bracket mounting hole size All dimensions for reference only and subject to change. Autoclave Engineers stock
Panel mounting drill size: 0.22 all valves. select products.
Consult factory.
G1 M G1 M M
G1 M M
M G H N G
H N
H N G
D D1
D
D1
D E E
E C
C C
B B
A B A
A
2-Way Straight 2-Way Angle 3-Way / 2 on Pressure
All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold. 11
Dimensions - inches (mm) Block
Outside
Catalog Stem Orifice Thick- Valve
Diameter
Number Type Diameter
Tube A B C D D1 E F G G1 H* M N ness Pattern
3-Way / 1 on Pressure
60VM4074 VEE 1/4 0.062 2.00 1.00 0.50 1.31 2.38 3.00 1.00 0.22 5.00 0.69 0.38 1.00
60VM4084 REG (6.35) (1.57) (50.80) (25.40) (12.70) (33.27) (60.45) (76.20) (25.40) (5.59) (127.00) (17.53) (9.65) (25.40)
60VM6074 VEE 3/8 0.062 2.00 1.00 0.53 1.31 2.62 3.00 1.00 0.22 5.25 0.69 0.38 1.00 See
60VM6084 REG (9.53) (1.57) (50.80) (25.40) (13.46) (33.27) (66.55) (76.20) (25.40) (5.59) (133.35) (17.53) (9.65) (25.40) Figure 4
60VM9074 VEE 9/16 0.078 2.62 1.31 0.72 1.31 2.81 3.00 1.00 0.28 5.44 0.69 0.38 1.50
60VM9084 REG (14.29) (1.98) (66.55) (33.27) (18.29) (33.27) (71.37) (76.20) (25.40) (7.11) (138.18) (17.53) (9.65) (38.10)
G - Packing gland mounting hole drill size * H Dimension is with stem in closed position. For prompt service, Parker
G1 - Bracket mounting hole size All dimensions for reference only and subject to change. Autoclave Engineers stock
Panel mounting drill size: 0.22 all valves. select products.
Consult factory.
D E
D D
E D1
E C
C C
B
D1 A
B B
A A
12 All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold.
Needle Valves - 100VM & 150V Series
Pressures to 150,000 psi (10350 bar)
Tube Pressure
Outside Rating
Diameter Orifice psi (bar)
Size Connection Size Rated @ Room
Inches Type Inches (mm) Cv* Temperature**
Series 100VM
1/4, 5/16, 3/8 F312C150 0.062 (1.57) .09 100,000 (6895)
Series 150V
5/16 F312C150 0.062 (1.57) .06 150,000 (10342)
Notes:
* CV values shown are for 2-way straight valve pattern. For 2-way
angle patterns, increase CV value 50%.
6
Number of turns open
2 100VM
Vee Stem
1
150V
0
10 20 30 40 50 60 70 80 90 100
% of rated Cv
NON-ROTATING
COLD WORKED 316/15-5PH STEM
SS BODY IN THREE
PATTERNS
LOCKING DEVICE
NON-ROTATING
STEM ADJUSTABLE PACKING
BELOW THREADS ADJUSTABLE PACKING
BELOW THREADS
ANTI-EXTRUSION
BACK-UP RINGS
15-5PH HIGH STRENGTH
STAINLESS STEEL
All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold. 13
Ordering Procedure
For complete information on available stem types, optional connections and additional valve options, see Needle Valve Options section or contact
your Sales Representative. The 100V Series valves are furnished complete with connection components, unless otherwise specified.
100VM 5 07 1 XX
Valve Outside Diameter Stem Body Options
Series Tube Size Type Pattern
For extreme
*4-1/4 07 - non-rotating 1 - two-way straight
100VM temperature and other
5-5/16 Vee stem (on off service) 2 - two-way angle
150V options, see Valve
*6-3/8 08 - non-rotating regulating 3 - three-way, two on pressure Options.
stem (tapered tip for
* Note: 1/4" and 3/8" for 100VM only. regulating shutoff
2-Way Straight
100VM4071 1/4" (6.35) 0.062 3.00 1.50 0.52 1.75 1.44 2.25 4.00 1.12 0.34 5.32 1.12 0.50 1.38 See
100VM5071 VEE 5/16" (7.93)
100VM6071 3/8" (9.53) (1.57) (76.20) (38.10) (13.21) (44.45) (36.58) (57.15) (101.60) (28.45) (8.64) (135.13) (28.45) (12.70) (35.05) Figure 1
2-Way Angle
100VM4072 1/4" (6.35) 0.062 2.25 1.50 0.52 1.44 3.00 4.00 1.12 0.34 6.05 0.94 0.50 1.38 See
100VM5072 VEE 5/16" (7.93)
100VM6072 3/8" (9.53) (1.57) (57.15) (38.10) (13.21) (36.58) (76.20) (101.60) (28.45) (8.64) (153.67) (23.88) (12.70) (35.05) Figure 2
G - Packing gland mounting hole drill size * H Dimension is with stem in closed position. For prompt service, Parker
G1 - Bracket mounting hole size All dimensions for reference only and subject to change. Autoclave Engineers stock
Panel mounting drill size: 0.22 all valves. select products.
Consult factory.
Figure 1 Figure 2
F F
G1 M M G M G1
G H N
H N
D
D1
D E
E
C C
B B
A A
2-Way Straight 2-Way Angle
14 All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold.
Outside Dimensions - inches (mm) Block
Catalog Stem Orifice Thick- Valve
Diameter
Number Type Diameter
Tube A B C D D1 E F G G1 H* M N ness Pattern
3-Way / 2 On Pressure
100VM4073 1/4" (6.35) 0.062 3.00 1.50 0.52 1.75 1.44 3.25 4.00 1.12 0.34 6.31 1.12 0.50 1.38 See
100VM5073 VEE 5/16" (7.93)
100VM6073 3/8" (9.53) (1.57) (76.20) (38.10) (13.21) (44.45) (36.58) (82.55) (101.60) (28.45) (8.64) (160.27) (28.45) (12.70) (35.05) Figure 3
G - Packing gland mounting hole drill size * H Dimension is with stem in closed position. For prompt service, Parker
G1 - Bracket mounting hole size All dimensions for reference only and subject to change. Autoclave Engineers stock
Panel mounting drill size: 0.22 all valves. select products.
See mounting note below for 150V series. Consult factory.
B B B
A A A Diameter
3-Way / 2 on Pressure 2-Way Angle / Replaceable Seat 2-Way Angle / Replaceable Seat
=
(2) 1/4"-20 mounting holes 180 apart
and (1) locking device screw 90 apart
All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold. 15
WARNING
FAILURE, IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS AND/OR SYSTEMS DESCRIBED HEREIN OR RELATED ITEMS CAN CAUSE DEATH, PERSONAL INJURY
AND PROPERTY DAMAGE.
This document and other information from Parker Hannifin Corporation, its subsidiaries and authorized distributors provide product and/or system options for further investiga-
tion by users having technical expertise. It is important that you analyze all aspects of your application and review the information concerning the product or system in the current
product catalog. Due to the variety of operating conditions and applications for these products or systems, the user, through its own analysis and testing, is solely responsible
for making the final selection of the products and systems and assuring that all performance, safety and warning requirements of the application are met. The products described
herein, including without limitation, product features, specifications, designs, availability and pricing, are subject to change by Parker Hannifin Corporation and its subsidiaries at
any time without notice.
Offer of Sale
The items described in this document are available for sale by Parker Hannifin Corporation, its subsidiaries or its authorized distributors. Any sale contract entered by Parker will be
governed by the provisions stated in Parker's standard terms and conditions of sale (copy available upon request).
2013 Parker Hannifin Corporation | Autoclave Engineers is a registered trademark of the Parker Hannifin Corporation 02-0113SE January2013
Instrumentation Products Division Parker Hannifin Manufacturing Ltd. Caution! Parker Autoclave Engineers Valves, Fittings and Tools are
Autoclave Engineers Operation Instrumentation Products Division, Europe not designed to work with common commercial instrument tubing
8325 Hessinger Drive Industrial Estate Whitemill and will only work with tubing built to Parker Autoclave Engineers
AES Specifications. Failure to do so will void warranty.
Erie, Pennsylvania 16509-4679 USA Wexford, Republic of Ireland
PH: 814-860-5700 FAX: 814-860-5811 PH: 353 53 914 1566
www.autoclave.com FAX: 353 53 914 1582 ISO-9001 Certified
Needle Valves
Pipe Valves
P Series
Pressures to 15,000 psi (1034 bar)
Since 1945 Parker Autoclave Engineers has
designed and built premium quality valves, fittings
and tubing. This commitment to engineering and
manufacturing excellence has earned Parker
Autoclave Engineers a reputation for reliable efficient
product performance. Parker Autoclave Engineers
has long been established as the world leader in high
pressure fluid handling components for the
chemical/petrochemical, research, and oil
and gas industries.
Parker Autoclave Engineers valves are complemented by a complete line of fittings, tubing,
check valves and line filters.
All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold.
www.autoclave.com 1
Valve Series - P Series
Pressures to 15,000 psi (1034 bar)
Tube Pressure
Outside Rating
Diameter Orifice psi (bar)
Size Connection Size Rated @ Room
Inches Type Inches (mm) Cv* Temperature**
Notes:
* CV values shown are for 2-way straight valve pattern. For 2-way
angle patterns, increase CV value 50%. (Based on water)
** For complete temperature ratings see pressure/temperature rating
guide in Technical Information section.
6
LOW FRICTION ALUMINUM POWDER COATED
STAINLESS STEEL
BRONZE PACKING GLAND
HANDLE 5 Regulating Stem
Number of turns open
ANTI-EXTRUSION
BACK-UP RINGS
ADJUSTABLE PACKING
BELOW THREADS
2
1 Vee Stem
0
10 20 30 40 50 60 70 80 90 100
CHOICE OF VEE OR PIPE CONNECTION
METAL-TO-METAL
REGULATING STEM TIP
SEATING % of rated Cv
Ordering Procedure
For complete information on available stem types, optional connections and additional valve options, see Needle Valve Options section or contact
your Sales Representative.
15P 4 07 1 XX
Valve Nominal Stem/Seat Body Options
Series Pipe Size Type Pattern
10P-10,000 psi (690 bar) 2-1/8 00 - rotating Vee stem 1 - two-way straight For extreme
4-1/4 (on-off service) temperature and
15P-15,000 psi (1034 bar) 2 - two-way angle other options, see
6-3/8 01 - rotating regulating stem Valve Options.
8-1/2 3 - three-way, two
(tapered tip for regulating
12-3/4 on pressure
and shut off)
16-1 4 - three-way, one
07 - non-rotating Vee stem on pressure
(on-off service)
Note: 3/4" and 1" 10,000 psi (690 bar) max. 5 - three-way, two stem
08 - non-rotating regulating manifold valve
stem (tapered tip for
regulating and shutoff)
2 All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold.
Valve Options Valve Maintenance
Extreme Temperatures Repair Kits: add R to the front of valve catalog
Standard Parker Autoclave Engineers valves with PTFE packing may be number for proper repair kit.
operated to 450F (232C). High temperature packing and/or extended (Example: R15P4071 or R10P12071)
stuffing box is available for service from 0F (-17.8C) to 650F (343C)
Valve Bodies: Valve bodies are available. Order using the eight (8)
by adding the following suffixes to catalog order number. digit part number found on the valve drawing or
TG standard valve with PTFE glass packing to 600F (316C).
GY standard valve with graphite braided yarn packing to 650F (343C). contact your Sales Representative for information.
B standard valve with cryogenic trim material and PTFE packing to Consult your Parker Autoclave Engineers representative for pricing on repair
-100F (-73C). kits and valve bodies. Refer to the Tools, Installation, Operation and Mainte-
LT extended stuffing box valve with PTFE packing and cryogenic trim nance section for proper maintenance procedures.
materials to -423F (-252C).
Parker Autoclave Engineers recommends pipe connections be operated between -423F (-252C) and 400F (204C). For additional valve options, contact your Sales Representative.
2-Way Straight
15P2001 VEE 1/8 0.078 1.50 0.75 0.56 0.82 1.25 1.75 0.56 0.16 2.53 0.45 0.20 0.63
15P2011 REG (3.18) (1.98) (38.10) (19.05) (14.22) (20.62) (31.75) (44.45) (14.22) (4.06) (64.26) (11.43) (5.16) (15.88)
15P4071 VEE 1/4 0.203 2.00 1.00 1.41 2.00 3.00 0.75 0.22 4.63 0.62 0.38 0.75
15P4081 REG (6.35) (5.16) (50.80) (25.40) (35.81) (50.80) (76.20) (19.05) (5.59) (117.60) (15.75) (9.65) (19.05)
15P6071 VEE 3/8 0.219 2.50 1.25 1.41 2.00 3.00 0.75 0.22 4.63 0.62 0.38 1.00
15P6081 REG (9.53) (5.56) (63.50) (31.75) (35.81) (50.80) (76.20) (19.05) (5.59) (117.60) (15.75) (9.65) (25.4) See
15P8071 VEE 1/2 0.312 3.00 1.50 2.06 2.88 4.00 1.00 0.34 5.93 0.69 0.50 1.38 Figure 1
15P8081 REG (12.70) (7.92) (76.20) (38.10) (52.32) (73.15) (101.60) (25.40) (8.64) (150.62) (17.53) (12.70) (35.05)
10P12071 VEE 3/4 0.437 3.50 1.75 2.63 3.75 10.25 1.12 0.44 7.00 0.88 0.63 1.75
10P12081 REG (19.05) (11.10) (88.90) (44.45) (66.80) (95.25) (260.35) (28.45) (11.18) (177.80) (22.35) (16.00) (44.45)
10P16071 VEE 1 0.562 4.12 2.06 3.31 4.62 10.25 1.62 0.56 9.00 1.25 1.13 1.75
10P16081 REG (25.40) (14.27) (104.65) (52.32) (84.07) (117.35) (260.35) (41.15) (14.22) (228.60) (31.75) (28.70 (44.45)
2-Way Angle
15P2002 VEE 1/8 0.078 1.50 0.75 0.56 1.38 1.75 0.56 0.16 2.66 0.45 0.20 0.63
15P2012 REG (3.18) (1.98) (38.10) (19.05) (14.22) (34.93) (44.45) (14.22) (4.06) (67.56) (11.43) (5.16) (15.88)
15P4072 VEE 1/4 0.203 2.00 1.00 1.41 2.44 3.00 0.75 0.22 4.81 0.62 0.38 0.75
15P4082 REG (6.35) (5.16) (50.80) (25.40) (35.81) (61.98) (76.20) (19.05) (5.59) (122.17) (15.75) (9.65) (19.05)
15P6072 VEE 3/8 0.219 2.50 1.25 1.41 2.44 3.00 0.75 0.22 4.81 0.62 0.38 1.00
15P6082 REG (9.53) (5.56) (63.50) (31.75) (35.81) (61.98) (76.20) (19.05) (5.59) (122.17) (15.75) (9.65) (25.40) See
15P8072 VEE 1/2 0.312 3.00 1.50 2.06 3.38 4.00 1.00 0.34 6.43 0.69 0.50 1.38 Figure 2
15P8082 REG (12.70) (7.92) (76.20) (38.10) (52.32) (85.85) (101.60) (25.40) (8.64) (163.32) (17.53) (12.70) (35.05)
10P12072 VEE 3/4 0.437 3.50 1.75 2.63 4.25 10.25 1.12 0.44 7.50 0.88 0.63 1.75
10P12082 REG (19.05) (11.10) (88.90) (44.45) (66.80) (107.95) (260.35) (28.45) (11.18) (190.50) (22.35) (16.00) (44.45)
10P16072 VEE 1 0.562 4.12 2.06 3.31 5.12 10.25 1.62 0.56 9.00 1.25 1.13 1.75
10P16082 REG (25.40) (14.27) (104.65) (52.32) (84.07) (130.05) (260.35) (41.15) (14.22) (228.60) (31.75) (28.70 (44.45)
3-Way / 2 on Pressure
15P4073 VEE 1/4 0.203 2.00 1.00 1.41 2.62 3.00 0.75 0.22 5.00 0.62 0.38 0.75
15P4083 REG (6.35) (5.16) (50.80) (25.40) (35.71) (66.55) (76.20) (19.05) (5.59) (127.00) (15.75) (9.65) (19.05)
15P6073 VEE 3/8 0.219 2.50 1.25 1.41 2.62 3.00 0.75 0.22 5.00 0.62 0.38 1.00
15P6083 REG (9.53) (5.56) (63.50) (31.75) (35.71) (66.55) (76.20) (19.05) (5.59) (127.00) (15.75) (9.65) (25.40)
15P8073 VEE 1/2 0.312 3.00 1.50 2.06 3.62 4.00 1.00 0.34 6.52 0.69 0.50 1.38 See
15P8083 REG (12.70) (7.92) (76.20) (38.10) (52.40) (91.95) (101.60) (25.40) (8.64) (165.61) (17.53) (12.70) (35.05) Figure 3
10P12073 VEE 3/4 0.437 3.50 1.75 2.65 4.62 10.25 1.12 0.44 7.88 0.88 0.63 1.75
10P12083 REG
(19.05) (11.10) (88.90) (44.45) (67.31) (117.35) (260.35) (28.45) (11.18) (200.15) (22.35) (16.00) (44.45)
10P16073 VEE 1 0.562 4.12 2.06 3.31 5.88 10.25 1.62 0.56 9.75 1.25 1.13 1.75
10P16083 REG (25.40) (14.27) (104.65) (52.32) (84.12) (149.35) (260.35) (41.15) (14.22) (247.65) (31.75) (28.70) (44.45)
G - Packing gland mounting hole drill size * H Dimension is with stem in closed position. For prompt service, Parker Autoclave stocks select products.
G1 - Bracket mounting hole size Consult factory.
Panel mounting drill size: 0.22 all valves. Panel mount screws for the 1/8" NPT are M3.5 x .7 thd. All dimensions for reference only and subject to change.
M M G
G1 G1 M M
M M G
G1 H N
N G H
H N
D D D
D D
E E E
D1 FOR
1/8 NPT B
A B
B A
All general terms and conditions of sale, including limitations
A of our liability, apply to all products and services sold. 3
2-Way Straight 2-Way Angle 3-Way /2 on Pressure
Outside Dimensions - inches (mm) Block
Catalog Stem Diameter Orifice Thick- Valve
Number Type Tube Diameter A B C D D1 E F G G1 H* M N ness Pattern
3-Way / 1 on Pressure
15P4074 VEE 1/4 .0203 2.00 1.00 1.41 2.44 3.00 0.75 0.22 4.81 0.62 0.38 0.75
15P4084 REG (6.35) (5.16) (50.80) (25.40) (35.71) (61.98) (76.20) (19.05) (5.59) (122.17) (15.75) (9.65) (19.05)
15P6074 VEE 3/8 0.219 2.50 1.25 1.41 2.44 3.00 0.75 0.22 4.81 0.62 0.38 1.00
15P6084 REG (9.53) (5.56) (63.50) (31.75) (35.71) (61.98) (76.20) (19.05) (5.59) (122.17) (15.75) (9.65) (25.40)
15P8074 VEE 1/2 0.312 3.00 1.50 2.06 3.38 4.00 1.00 0.34 6.31 0.69 0.50 1.38 See
15P8084 REG (12.70) (7.92) (76.20) (38.10) (52.40) (85.85) (101.60) (25.40) (8.64) (160.27) (17.53) (12.70) (35.05) Figure 4
10P12074 VEE 3/4 0.437 3.50 1.75 2.65 4.25 10.25 1.12 0.44 7.50 0.88 0.63 1.75
10P12084 REG (19.05) (11.10) (88.90) (44.45) (67.31) (107.95) (260.35) (28.45) (11.18) (190.50) (22.35) (16.00) (44.45)
10P16074 VEE 1 0.562 4.12 2.06 3.31 5.12 10.25 1.62 0.56 9.09 1.25 1.13 1.75
10P16084 REG (25.40) (14.27) (104.65) (52.32) (84.07) (130.05) (260.35) (41.15) (14.22) (230.89) (31.75) (28.70) (44.45)
3-Way/2-Stem Manifold
15P4075 VEE 1/4 0.203 2.00 1.00 1.69 1.19 3.38 3.00 0.75 0.22 5.75 0.62 0.38 0.75
15P4085 REG (6.35) (5.16) (50.80) (25.40) (42.88) (30.18) (85.85) (76.20) (19.05) (5.59) (146.05) (15375) (9.65) (19.05)
15P6075 VEE 3/8 0.219 2.50 1.25 1.69 1.19 3.38 3.00 0.75 0.22 5.75 0.62 0.38 1.00
15P6085 REG (9.53) (5.56) (63.50) (31.75) (42.88) (30.18) (85.85) (76.20) (19.05) (5.59) (146.05) (15.75) (9.65) (25.40)
15P8075 VEE 1/2 0.312 3.00 1.50 2.56 1.75 5.12 4.00 1.00 0.34 8.05 0.69 0.50 1.38 See
15P8085 REG (12.70) (7.92) (76.20) (38.10) (65.07) (44.45) (130.05) (101.60) (25.40) (8.64) (204.47) (17.53) (12.70) (35.05) Figure 5
10P12075 VEE 3/4 0.437 3.50 1.75 3.25 2.25 6.50 10.25 1.12 0.44 9.75 0.88 0.63 1.75
10P12085 REG (19.05) (11.10)
(88.90) (44.45) (82.55) (57.15) (165.10) (260.35) (28.45) (11.18) (247.65) (22.35) (16.00) (44.45)
10P16075 VEE 1 0.562 4.12 2.06 3.75 2.81 7.50 10.25 1.62 0.56 11.47 1.25 1.13 1.75
10P16085 REG (25.40) (14.27)
(104.65) (52.32) (95.25) (71.42) (190.50) (260.35) (41.15) (14.22) (291.38) (31.75) (28.70) (44.45)
G - Packing gland mounting hole drill size *H Dimension is with stem in closed position. For prompt service, Parker
G - Bracket mounting hole size All dimensions for reference only and subject to change. Autoclave Engineers stocks select
1
Panel mounting drill size: 0.22 all valves. products. Consult factory.
WARNING
FAILURE, IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS AND/OR SYSTEMS DESCRIBED HEREIN OR RELATED ITEMS CAN CAUSE DEATH, PERSONAL INJURY AND PROPERTY DAMAGE.
This document and other information from Parker Hannifin Corporation, its subsidiaries and authorized distributors provide product and/or system options for further investigation by users having technical
expertise. It is important that you analyze all aspects of your application and review the information concerning the product or system in the current product catalog. Due to the variety of operating conditions
and applications for these products or systems, the user, through its own analysis and testing, is solely responsible for making the final selection of the products and systems and assuring that all performance,
safety and warning requirements of the application are met. The products described herein, including without limitation, product features, specifications, designs, availability and pricing, are subject to change by
Parker Hannifin Corporation and its subsidiaries at any time without notice.
Offer of Sale
The items described in this document are available for sale by Parker Hannifin Corporation, its subsidiaries or its authorized distributors. Any sale contract entered by Parker will be governed by the provisions
stated in Parker's standard terms and conditions of sale (copy available upon request).
2013 Parker Hannifin Corporation | Autoclave Engineers is a registered trademark of the Parker Hannifin Corporation 02-1251SE January2013
Instrumentation Products Division Parker Hannifin Manufacturing Ltd. Caution! Parker Autoclave Engineers Valves, Fittings and Tools are
not designed to work with common commercial instrument tubing
Autoclave Engineers Operation Instrumentation Products Division, Europe
and will only work with tubing built to Parker Autoclave Engineers
8325 Hessinger Drive Industrial Estate Whitemill
AES Specifications. Failure to do so will void warranty.
Erie, Pennsylvania 16509-4679 USA Wexford, Republic of Ireland
PH: 814-860-5700 FAX: 814-860-5811 PH: 353 53 914 1566
www.autoclave.com FAX: 353 53 914 1582 ISO-9001 Certified
Needle Valves
Mini Valves
MVE/MV Series
Pressures to 15,000 psi (1034 bar)
www.autoclave.com
Needle Valves - MVE/MV Series
Pressures to 15,000 psi (1034 bar)
Tube Pressure
Outside Rating
Diameter Orifice psi (bar)
Size Connection Size Rated @ Room
Inches Type Inches (mm) Cv* Temperature**
Notes:
* CV values shown are for 2-way straight valve pattern. For 2-way
angle patterns, increase CV value 50%. (Based on water)
ANODIZED
ALUMINUM HANDLE
316 PACKING
GLAND
M3.5 x .6 SCREW
SPACER
COLD WORKED
TYPE 316 SS ADJUSTABLE PACKING
BODY IN FIVE BELOW THREADS
PATTERNS
ANTI-EXTRUSION
BACKUP RINGS
SPEEDBITE
"W" TUBE
SPEEDBITE
CONNECTION
"W" TUBE METAL-TO-METAL
CONNECTION VEE STEM TIP SEATING
Ordering Procedure
For complete information on valve options, contact your Sales Representative. MVE Series valves are furnished complete with connection
components, unless otherwise specified.
MVE 2 00 1 XX
Valve Outside Diameter Stem Body Options
Series Tube Size Type Pattern
See valve options
MVE - 3/8 Hex tubing 1-1/16 00 - rotating Vee stem 1 - two-way straight
for ratings.
glands 2-1/8 (on-off service) 2 - two-way angle
MV - 10mm Hex tubing 01 - rotating Regulating stem 3 - three-way, two on pressure
glands (tapered tip for regulating 4 - three way, one on pressure
and shut-off)
5 - three-way, two stem
manifold valve
2 All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold.
Valve Options Valve Maintenance
Extreme Temperatures Refer to the Tools, Installation, Operation and Maintenance section for
Standard Parker Autoclave Engineers valves with PTFE packing may proper maintenance procedures.
be operated to 450F (232C). High temperature packing is available
for service from 0F (-17.8C) to 600F (316C) by adding the fol-
lowing suffixes to catalog order number.=
TG standard valve with PTFE glass packing to 600F (316C).
2-Way Straight
MVE1001 VEE 1/16 0.055 1.38 0.69 0.45 0.81 0.56 1.13 1.75 0.56 0.16 2.38 0.45 0.20 0.56
MV1001 VEE (1.57) (1.40) (34.93) (17.45) (11.43) (20.65) (14.30) (28.58) (44.45) (14.27) (4.04) (60.38) (11.49) (5.16) (14.27) See
MVE2001 VEE 1/8 0.078 1.38 0.69 0.45 0.81 0.56 1.13 1.75 0.56 0.16 2.38 0.45 0.20 0.56 Figure 1
MV2001 VEE (3.18) (1.98) (34.93) (17.45) (11.43) (20.65) (14.30) (28.58) (44.45) (14.27) (4.04) (60.38) (11.49) (5.16) (14.27)
2-Way Angle
MVE1002 VEE 1/16 0.055 1.38 0.69 0.45 0.56 1.38 1.75 0.56 0.16 2.63 0.45 0.20 0.56
MV1002 VEE (1.57) (1.40) (34.93) (17.45) (11.43) (14.30) (34.93) (44.45) (14.27) (4.04) (66.75) (11.49) (5.16) (14.27) See
MVE2002 VEE 1/8 0.078 1.38 0.69 0.45 0.56 1.38 1.75 0.56 0.16 2.38 0.45 0.20 0.56 Figure 2
MV2002 VEE (3.18) (1.98) (34.93) (17.45) (11.43) (14.30) (34.93) (44.45) (14.27) (4.04) (60.38) (11.49) (5.16) (14.27)
3-Way / 2 on Pressure
MVE1003 VEE 1/16 0.055 1.38 0.69 0.45 0.81 0.56 1.44 1.75 0.56 0.16 2.69 0.45 0.20 0.56
MV1003 VEE (1.57) (1.40) (34.93) (17.45) (11.43) (20.65) (14.30) (36.50) (44.45) (14.27) (4.04) (68.30) (11.49) (5.16) (14.27) See
MVE2003 VEE 1/8 0.078 1.38 0.69 0.45 0.81 0.56 1.44 1.75 0.56 0.16 2.69 0.45 0.20 0.56 Figure 3
MV2003 VEE (3.18) (1.98) (34.93) (17.45) (11.43) (20.65) (14.30) (36.50) (44.45) (14.27) (4.04) (68.30) (11.49) (5.16) (14.27)
G - Packing gland mounting hole drill size * H Dimension is with stem in closed position. For prompt service, Parker Autoclave
G1 - Bracket mounting hole size All dimensions for reference only and subject to change. Engineers stocks select products.
Panel mounting screws are M3.5 x .7 thd. Consult factory.
Tube glands are 3/8 hex on standard MVE models
Tube glands are 10mm hex on MV models.
G1 M M G1 M M M M
G1
G G G
H N H N N
H
D1 D D D
D
E E E
C C C
B
B B
A A A
2-Way Straight 2-Way Angle 3-Way / 2 on Pressure
All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold. 3
Outside Dimensions - inches (mm) Block
Catalog Stem Diameter Orifice Thick- Valve
Number Type Tube Diameter A B C D D1 E F G G1 H* M N ness Pattern
3-Way / 1 on Pressure
MVE1004 VEE 1/16 0.055 1.38 0.69 0.45 0.56 0.56 1.44 1.75 0.56 0.16 2.69 0.45 0.20 0.56
MV1004 VEE (1.57) (1.40) (34.93) (17.45) (11.43) (14.22) (14.30) (36.50) (44.45) (14.27) (4.04) (68.30) (11.49) (5.16) (14.27) See
MVE2004 VEE 1/8 0.078 1.38 0.69 0.45 0.56 0.56 1.44 1.75 0.56 0.16 2.69 0.45 0.20 0.56 Figure 4
MV2004 VEE (3.18) (1.98) (34.93) (17.45) (11.43) (14.22) (14.30) (36.50) (44.45) (14.27) (4.04) (68.30) (11.49) (5.16) (14.27)
G - Packing gland mounting hole drill size * H Dimension is with stem in closed position. For prompt service, Parker
G1 - Bracket mounting hole size All dimensions for reference only and subject to change. Autoclave stocks select products.
Panel mounting screws are M3.5 x .7 thd. Consult factory.
Tube glands are 3/8 hex on standard MVE models
Tube glands are 10mm hex on MV models
Figure 4 Figure 5
F F
M M G1 M M
G1 G
G N
H N
D D
D D H E
E
D1
C
A
B B
A
WARNING
FAILURE, IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS AND/OR SYSTEMS DESCRIBED HEREIN OR RELATED ITEMS CAN CAUSE DEATH, PERSONAL INJURY
AND PROPERTY DAMAGE.
This document and other information from Parker Hannifin Corporation, its subsidiaries and authorized distributors provide product and/or system options for further investiga-
tion by users having technical expertise. It is important that you analyze all aspects of your application and review the information concerning the product or system in the current
product catalog. Due to the variety of operating conditions and applications for these products or systems, the user, through its own analysis and testing, is solely responsible
for making the final selection of the products and systems and assuring that all performance, safety and warning requirements of the application are met. The products described
herein, including without limitation, product features, specifications, designs, availability and pricing, are subject to change by Parker Hannifin Corporation and its subsidiaries at
any time without notice.
Offer of Sale
The items described in this document are available for sale by Parker Hannifin Corporation, its subsidiaries or its authorized distributors. Any sale contract entered by Parker will be
governed by the provisions stated in Parker's standard terms and conditions of sale (copy available upon request).
2013 Parker Hannifin Corporation | Autoclave Engineers is a registered trademark of the Parker Hannifin Corporation 02-0114SE January2013
Instrumentation Products Division Parker Hannifin Manufacturing Ltd. Caution! Parker Autoclave Engineers Valves, Fittings and Tools are
Autoclave Engineers Operation Instrumentation Products Division, Europe not designed to work with common commercial instrument tubing
8325 Hessinger Drive Industrial Estate Whitemill and will only work with tubing built to Parker Autoclave Engineers
AES Specifications. Failure to do so will void warranty.
Erie, Pennsylvania 16509-4679 USA Wexford, Republic of Ireland
PH: 814-860-5700 FAX: 814-860-5811 PH: 353 53 914 1566
www.autoclave.com FAX: 353 53 914 1582 ISO-9001 Certified
Needle Valves
Low Pressure
All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold.
www.autoclave.com 1
Valve Series - BTV Series
Pressures to 15,000 psi (1034 bar)
ALUMINUM HANDLE
PACKING GLAND
LOCKING
COLD WORKED TYPE 316
DEVICE
SS VALVE BODY
NON-ROTATING
STEM
METAL-TO-METAL
SEATING
Ordering Procedure
For complete information on available stem types, optional connections and additional valve options, see Needle Valve Options section or contact
your Sales Representative. BTV Series valves are furnished complete with connection components, unless otherwise specified.
BTV 4 S 4 P 1 XX
Valve Male NPT Male NPT Female Female Body Options
Series Position Port Sizes Connection Type Pattern R - Regulating
2-1/8 F - Front 2-1/8 P - NPT 1 - Straight Stem
4-1/4 S - Side 4-1/4 L - Low Pressure 2 - Angle
6-3/8 B - Bottom 6-3/8 3 - 3 Way 2 on
8-1/2 8-1/2 Pressure *2
4 - 3 Way 1 on
*Note: 1 inlet is NPT male Pressure *1
2 inlets are NPT male and 1 female connection
2 All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold.
Dimensions - inches (mm)
Catalog Stem Pipe/ Orifice
Valve
Number Type Tube Diameter A B C D D1 D2 E F G H M Block Thickness Pattern
2-Way Straight
BTV4S4P1 VEE 1/4 0.094 2.00 1.31 0.69 0.82 0.82 1.28 1.50 0.61 3.41 0.56 0.75 See
Side Inlet (6.35) (2.39) (50.80) (33.27) (17.53) (20.83) (20.83) (32.51) (38.10) (15.49) (86.61) (14.22) (19.05) Figure 1
BTV4F2L1 VEE 1/8 0.094 1.50 0.75 0.63 0.81 0.88 1.38 1.50 0.61 3.49 0.56 0.63 See
Front Inlet (3.18) (2.39) (38.10) (19.05) (15.88) (20.57) (22.35) (35.05) (38.10) (15.49) (88.65) (14.22) (16.00) Figure 2
2-Way Angle
BTV4B2L2 VEE 1/8 0.094 2.00 1.00 0.81 1.19 1.63 1.50 0.75 4.75 0.62 0.75 See
Bottom Inlet (3.18) (2.39) (50.80) (25.40) (20.57) (30.23) (41.40) (38.10) (19.05) (120.65) (15.75) (19.05) Figure 3
BTV4B4P2 VEE 1/4 0.203 1.50 1.00 1.25 1.19 1.63 3.00 0.75 5.30 0.62 0.75 See
Bottom Inlet (6.35) (5.16) (38.10) (25.40) (31.75) (30.23) (41.40) (76.20) (19.05) (134.62) (15.75) (19.05) Figure 3
M
M M G
H G G H
H
D
D D1 D D2
E
E E
B C
C B C
A A B
A
2-Way Straight 2-Way Straight 2-Way Angle
3-Way/2 on Pressure
BTV4F2L3 VEE 1/8 0.094 1.50 0.75 0.63 0.81 1.06 0.88 1.38 1.50 0.75 3.49 0.50 0.75 See
Front Inlet (3.18) (2.39) (38.10) (19.05) (15.88) (20.57) (26.92) (22.35) (34.93) (38.10) (19.05) (88.65) (12.70) (19.05) Figure 4
3-Way/1 on Pressure
BTV4F2L4 VEE 1/8 0.094 1.50 .75 0.63 0.81 0.81 0.88 1.38 1.50 0.75 3.49 0.50 0.75 See
Front Inlet (3.18) (2.39) (38.10) (19.05) (15.88) (20.57) (20.57) (22.35) (34.93) (38.10) (19.05) (86.66) (12.70) (19.05) Figure 5
Figure 4 Figure 5
F F
M M
G H G H
D D1 D2 D D1 D2
E E
B C B C
A A
G - Packing gland mounting hole drill size * H Dimension is with stem in closed position. For prompt service, Parker Autoclave
Engineers stocks select products.
Consult factory.
All dimensions for reference only and subject to change.
All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold. 3
WARNING
FAILURE, IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS AND/OR SYSTEMS DESCRIBED HEREIN OR RELATED ITEMS CAN CAUSE DEATH, PERSONAL INJURY AND PROPERTY DAMAGE.
This document and other information from Parker Hannifin Corporation, its subsidiaries and authorized distributors provide product and/or system options for further investigation by users having technical
expertise. It is important that you analyze all aspects of your application and review the information concerning the product or system in the current product catalog. Due to the variety of operating conditions
and applications for these products or systems, the user, through its own analysis and testing, is solely responsible for making the final selection of the products and systems and assuring that all performance,
safety and warning requirements of the application are met. The products described herein, including without limitation, product features, specifications, designs, availability and pricing, are subject to change by
Parker Hannifin Corporation and its subsidiaries at any time without notice.
Offer of Sale
The items described in this document are available for sale by Parker Hannifin Corporation, its subsidiaries or its authorized distributors. Any sale contract entered by Parker will be governed by the provisions
stated in Parker's standard terms and conditions of sale (copy available upon request).
2013 Parker Hannifin Corporation | Autoclave Engineers is a registered trademark of the Parker Hannifin Corporation 02-1248SE January 2013
Instrumentation Products Division Parker Hannifin Manufacturing Ltd. Caution! Parker Autoclave Engineers Valves, Fittings and Tools are
not designed to work with common commercial instrument tubing
Autoclave Engineers Operation Instrumentation Products Division, Europe
and will only work with tubing built to Parker Autoclave Engineers
8325 Hessinger Drive Industrial Estate Whitemill
AES Specifications. Failure to do so will void warranty.
Erie, Pennsylvania 16509-4679 USA Wexford, Republic of Ireland
PH: 814-860-5700 FAX: 814-860-5811 PH: 353 53 914 1566
www.autoclave.com FAX: 353 53 914 1582 ISO-9001 Certified
Needle Valves
MicroMetering
VRMM Series
Pressures to 60,000 psi (4137 bar)
MicroMetering valves are designed for applications
where more precise control of small flows is required
than is possible with a standard regulating stem. Barrel
and Thimble micrometer design permits settings to be
repeated.
Metering is effected by a finely tapered stem acting in a
precisely mated replaceable seat. Very fine stem
position is achieved utilizing a 40 TPI thread. The
Barrel and Thimble are set for proper metering at the
factory.
These valves are designed for metering only and
cannot be used as a shutoff valve. Minimum flow is
factory set and occurs at 0 position. DO NOT
OPERATE THE VALVE BELOW THE ZERO POSITION OR
DAMAGE WILL RESULT. When shutoff action is re-
quired, a correlated shutoff valve from Parker AE series
10V, 30VM or 60VM should be installed in series with
the MicroMetering valve.
www.autoclave.com
Needle Valves - MicroMetering
Pressures to 60,000 psi (4137 bar)
Tube Pressure
Outside Rating
Diameter Orifice psi (bar)
Size Connection Size Rated @ Room
Inches Type Inches (mm) Cv Temperature**
.
Note:
LOCKING DEVICE
0.125
(3.18)
ADJUSTABLE 0.100
PACKING BELOW
THREADS
(2.54)
*NON-ROTATING
STEM 0.075
(1.90)
STAINLESS
0.050
STEEL BODY REPLACEABLE SEAT
(1.27)
0.025
(.64)
0
0.001 0.002 0.003 0.004
Cv
Ordering Procedure
For complete information on available stem types, optional connections and additional valve options, see Needle Valve Options section or contact
your Sales Representative. VRMM Series valves are furnished complete with connection components, unless otherwise specified.
60VRMM 4 81 2 XX
Valve Outside Diameter Stem/Seat Body Options
Series Tube Size Type Pattern
For extreme
10VRMM 2-1/8 81 - Rotating regulating one 2 - two-way angle
temperature and other
30VRMM 4-1/4 piece stem with replaceable seat.
options, see
60VRMM 6-3/8 Valve Options.
NOTE:
Ordering procedure for information only. Models available are shown in tables on next page.
2 All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold.
Valve Options Valve Maintenance
Extreme Temperatures Repair Kits: add R to the front of valve catalog
Standard Parker Autoclave Engineers valves with PTFE packing may be number for proper repair kit.
operated to 450F (232C). High temperature packing and/or extended (Example: R60VRMM)
stuffing box is available for service from -423F (-252C) to 1200F Valve Bodies: Valve bodies are available. Order using the eight (8)
(649C) by adding the following suffixes to catalog order number digit part number found on the valve drawing or
TG - standard valve with PTFE glass packing to 600F (316C). See note below. contact your Sales Representative for information.
GY - standard valve with graphite braided yarn packing to 800F (427C).
HT - extended stuffing box valve with graphite braided yarn packing to 1200F (649C).
B - standard valve with cryogenic trim material and PTFE packing to -100F (-73C). Consult your Parker Autoclave Engineers representative for pricing on repair
kits and valve bodies. Refer to the Tools, Installation, Operation and
LT - extended stuffing box valve with PTFE packing & Cryogenic trim materials to
Maintenance section for proper maintenance procedures.
-423F (-252C).
Note: 60VRMM valves supplied with Peak/PTFE Glass/Peek
Parker Autoclave Engineers does not recommend compression sleeve connec-
tions below 0F (-17.8C) or above 650F (343C). For additional valve options,
contact your Sales Representative.
See Needle Valve options for stem and seat coatings for erosive service.
10VRMM2812 1/8 0.062 1.50 0.88 0.31 0.94 1.56 3.00 0.62 0.16 5.06 1.00 0.25 0.75
(3.17) (1.57) (38.10) (22.35) (7.87) (23.87) (39.62) (76.20) (15.74) (4.06) (128.52) (25.40) (6.35) (19.05)
See
Figure 1
* Note: M dimension is distance between holes for mounting bracket.
30VRMM4812 1/4 0.062 2.00 1.00 0.50 1.12 2.00 3.00 0.97 0.22 5.06 0.69 0.50 1.00
(6.35) (1.57) (50.80) (25.40) (12.70) (28.44) (50.80) (76.20) (24.63) (5.58) (128.52) (17.25) (12.70) (25.40)
60VRMM4812 1/4 0.062 2.00 1.00 0.50 1.31 2.63 3.00 0.97 0.22 6.06 0.69 0.38 1.00 See
(6.35) (1.57) (50.80) (25.40) (12.70) (33.27) (66.80) (76.20) (24.63) (5.58) (153.92) (17.25) (9.65) (25.40) Figure 2
60VRMM6812 3/8 0.062 2.00 1.00 0.53 1.31 2.63 3.00 0.97 0.22 6.06 0.69 0.38 1.00
(9.53) (1.57) (50.80) (25.40) (13.46) (33.27) (66.80) (76.20) (24.63) (5.58) (153.92) (17.25) (9.65) (25.40)
G - Packing gland mounting hole drill size * H Dimension is with stem in closed position. For prompt service, Parker
G1 - Bracket mounting hole size All dimensions for reference only and subject to change. Autoclave Engineers stocks select
Panel mounting drill size: 0:22 all valves. products. Consult factory.
Figure 1 Figure 2
F F
G1 G1 M M
G G
H .312
(79.24) H N
D D
M
E E
C
C
N
B B
A
A
10VRMM 30VRMM/60VRMM
All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold. 3
WARNING
FAILURE, IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS AND/OR SYSTEMS DESCRIBED HEREIN OR RELATED ITEMS CAN CAUSE DEATH, PERSONAL INJURY
AND PROPERTY DAMAGE.
This document and other information from Parker Hannifin Corporation, its subsidiaries and authorized distributors provide product and/or system options for further investiga-
tion by users having technical expertise. It is important that you analyze all aspects of your application and review the information concerning the product or system in the current
product catalog. Due to the variety of operating conditions and applications for these products or systems, the user, through its own analysis and testing, is solely responsible
for making the final selection of the products and systems and assuring that all performance, safety and warning requirements of the application are met. The products described
herein, including without limitation, product features, specifications, designs, availability and pricing, are subject to change by Parker Hannifin Corporation and its subsidiaries at
any time without notice.
Offer of Sale
The items described in this document are available for sale by Parker Hannifin Corporation, its subsidiaries or its authorized distributors. Any sale contract entered by Parker will be
governed by the provisions stated in Parker's standard terms and conditions of sale (copy available upon request).
2013 Parker Hannifin Corporation | Autoclave Engineers is a registered trademark of the Parker Hannifin Corporation 02-0115SE January2013
Instrumentation Products Division Parker Hannifin Manufacturing Ltd. Caution! Parker Autoclave Engineers Valves, Fittings and Tools are
Autoclave Engineers Operation Instrumentation Products Division, Europe not designed to work with common commercial instrument tubing
8325 Hessinger Drive Industrial Estate Whitemill and will only work with tubing built to Parker Autoclave Engineers
Erie, Pennsylvania 16509-4679 USA Wexford, Republic of Ireland AES Specifications. Failure to do so will void warranty.
MVBB Series
Pressures to 20,000 psi (1379 bar)
www.autoclave.com
Needle Valves - MVBB Series
Pressures to 20,000 psi (1379 bar)
Tube Pressure
Outside Rating
Diameter Orifice psi (bar)
Size Connection Size Rated @ Room
Inches Type Inches (mm) Cv Temperature**
Notes:
VENT
ANODIZED
ALUMINUM HANDLES
LOCKING DEVICE
GAUGE IN
ROTATING
MEDIUM PRESSURE STEM
CONED AND THREADED
CONNECTION
PTFE
PACKING
ANTI-EXTRUSION
BACK UP RINGS
Valve Options
Extreme Temperatures
Standard Parker Autoclave Engineers valves with PTFE packing may be operated to 450F (232C). High temperature packing is available for
service from 0F (-17.8C) to 800F (427C) by adding the following suffixes to catalog order number.
TG standard valve with PTFE glass packing to 600F (316C)
GY standard valve with Graphite braided yarn packing to 800F (427C).
Note: Refer to the Tools, Installation, Operation and Maintenance section for proper maintenance procedures.
2 All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold.
Outside Dimensions - inches (mm)
Catalog Stem Diameter Orifice
Number Type Tube Diameter A B C D D1 E F G G1 H* M N O P Q
20MVBB4 VEE 1/4 0.094 3.50 0.813 0.38 0.625 0.938 1.50 1.75 0.56 0.281 2.94 2.50 0.485 1.63 .500 2.625
(6.35) (2.39) (88.90) (20.65) (9.65) (15.88) (23.83) (38.10) (44.45) (14.27) (7.14) (74.68) (63.50) (12.32) (41.40) 12.70 66.68
20MVBB6 VEE 3/8 0.094 3.88 1.00 0.44 0.625 0.938 1.50 1.75 0.56 0.281 2.94 2.88 0.50 1.63 .500 2.625
(9.53) (2.39) (98.60) (25.40) (11.10) (15.88) (23.83) (38.10) (44.45) (14.27) (7.14) (74.68) (73.15) (12.70) (41.40) 12.70 66.68
For complete information on available options, contact your Sales representative. MVBB Series valves are furnished with connection
components unless otherwise specified.
M N
G1
Q
O
D H
D1
E
B B
A
G - Packing gland mounting hole drill size * H Dimension is with stem in closed position. For prompt service, Parker
G1 - Bracket mounting hole size All dimensions for reference only and subject to change. Autoclave Engineers stocks
select products.
Consult factory.
All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold. 3
WARNING
FAILURE, IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS AND/OR SYSTEMS DESCRIBED HEREIN OR RELATED ITEMS CAN CAUSE DEATH, PERSONAL INJURY
AND PROPERTY DAMAGE.
This document and other information from Parker Hannifin Corporation, its subsidiaries and authorized distributors provide product and/or system options for further investiga-
tion by users having technical expertise. It is important that you analyze all aspects of your application and review the information concerning the product or system in the current
product catalog. Due to the variety of operating conditions and applications for these products or systems, the user, through its own analysis and testing, is solely responsible
for making the final selection of the products and systems and assuring that all performance, safety and warning requirements of the application are met. The products described
herein, including without limitation, product features, specifications, designs, availability and pricing, are subject to change by Parker Hannifin Corporation and its subsidiaries at
any time without notice.
Offer of Sale
The items described in this document are available for sale by Parker Hannifin Corporation, its subsidiaries or its authorized distributors. Any sale contract entered by Parker will be
governed by the provisions stated in Parker's standard terms and conditions of sale (copy available upon request).
2013 Parker Hannifin Corporation | Autoclave Engineers is a registered trademark of the Parker Hannifin Corporation 02-0116SE January2013
Instrumentation Products Division Parker Hannifin Manufacturing Ltd. Caution! Parker Autoclave Engineers Valves, Fittings and Tools are
Autoclave Engineers Operation Instrumentation Products Division, Europe not designed to work with common commercial instrument tubing
8325 Hessinger Drive Industrial Estate Whitemill and will only work with tubing built to Parker Autoclave Engineers
Erie, Pennsylvania 16509-4679 USA Wexford, Republic of Ireland AES Specifications. Failure to do so will void warranty.
20DBNV Series
Pressures to 20,000 psi (1379 bar)
Parker Autoclave Engineers' valves are complemented by a complete line of fittings, tubings
and accessories. The 20DBNV Series uses Parker Autoclave Engineers' pressure connections.
This coned and threaded connection provides a reliable bubble-tight seal for dependable
performance in gas or liquid service.
Double Block and Bleed
www.autoclave.com
Needle Valves - 20DBNV Series
Pressures to 20,000 psi (1379 bar)
Tube Pressure
Outside Rating
Diameter Orifice psi (bar)
Size Connection Size Rated @ Room
Inches Type Inches (mm) Cv Temperature**
Notes:
POWDER COATED
ALUMINUM BRONZE
STAINLESS STEEL
PACKING GLAND
HANDLE
ANTI-EXTRUSION
BACK-UP RINGS
PLUGGED
INLET
VENT VALVE
BOTTOM VIEW
Valve Options
Extreme Temperatures
Standard Parker Autoclave Engineers' valves with PTFE packing may be operated to 450F (232C). High temperature packing is available for
service from 0F (-17.8C) to 800F (427C) by adding the following suffixes to catalog order number.
TG standard valve with PTFE glass packing to 600F (316C).
B standard valve with cryogenic trim material and PTFE packing to -100F (-73C).
For additional valve options, contact your Sales Representative.
Note: Refer to the Tools, Installation, Operation and Maintenance section for proper maintenance procedures.
2 All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold.
Ordering Procedure
For complete information on available end connections, see end connections options below. 20DBNV valves are furnished complete with tube
connections.
20DBNV M4 M4 XXX
Valve Tube Vent Connection Options
Series Connection M4 - SF250CX20 TG - PTFE Glass Packing
20DBNV Double M4 - SF250CX20 (see chart below) B - Cryogenic Trim
Block & Bleed M6 - SF375CX20
-100F (-73C)
Needle Valve H9 - F562C
(see chart below) K - Anti-vibration Collet &
Gland Assembly
Connection Options
Catalog Tube Connection MAWP @ Vent Connection Vent
Number Number Connection Room Temperature Number Connection
All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold. 3
Catalog Stem Pipe Orifice Dimensions - inches (mm)
Number Type Size Dia. A B C D D1 E F G H M N O P Q V X
1/4 0.094 5.25 1.00 0.38 1.50 1.13 2.13 3.00 1.00 4.65 0.69 0.50 0.75 0.63 1.50 1.43 .50
20DBNVM4M4 VEE
(6.35) (2.39) (133.35) (25.40) (9.65) (38.10) (28.70) (54.10) (76.20) (25.40) (118.11) (17.53) (12.70) (19.05) (16.00) (38.10) (36.32) (12.70)
3/8 0.094 5.25 1.00 0.44 1.50 1.13 2.13 3.00 1.00 4.65 0.69 0.50 0.75 0.63 1.50 1.43 .50
20DBNVM6M4 VEE
(9.53) (2.39) (133.35) (25.40) (11.18) (38.10) (28.70) (54.10) (76.20) (25.40) (118.11) (17.53) (12.70) (19.05) (16.00) (38.10) (36.32) (12.70)
9/16 0.094 5.88 1.31 0.53 1.50 1.13 3.00 3.00 1.00 5.53 0.69 0.50 1.38 0.63 1.75 1.43 .75
20DBNVH9M4 VEE
(14.29) (2.39) (149.35) (33.27) (13.46) (38.10) (28.70) (76.20) (76.20) (25.40) (140.46) (17.53) (12.70) (35.05) (16.00) (44.45) (36.32) (19.05)
For complete information on available options, contact your Sales representative. 20DBNV Series valves are furnished with connection
components unless otherwise specified.
B N
VENT OUTLET
O B
A X
Q
P
VENT VALVE
V
BOTTOM VIEW
WARNING
FAILURE, IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS AND/OR SYSTEMS DESCRIBED HEREIN OR RELATED ITEMS CAN CAUSE DEATH, PERSONAL INJURY AND PROPERTY DAMAGE.
This document and other information from Parker Hannifin Corporation, its subsidiaries and authorized distributors provide product and/or system options for further investigation by users having technical
expertise. It is important that you analyze all aspects of your application and review the information concerning the product or system in the current product catalog. Due to the variety of operating conditions
and applications for these products or systems, the user, through its own analysis and testing, is solely responsible for making the final selection of the products and systems and assuring that all performance,
safety and warning requirements of the application are met. The products described herein, including without limitation, product features, specifications, designs, availability and pricing, are subject to change by
Parker Hannifin Corporation and its subsidiaries at any time without notice.
Offer of Sale
The items described in this document are available for sale by Parker Hannifin Corporation, its subsidiaries or its authorized distributors. Any sale contract entered by Parker will be governed by the provisions
stated in Parker's standard terms and conditions of sale (copy available upon request).
2013 Parker Hannifin Corporation | Autoclave Engineers is a registered trademark of the Parker Hannifin Corporation 02-9259BE January 2013
Instrumentation Products Division Parker Hannifin Manufacturing Ltd. Caution! Parker Autoclave Engineers Valves, Fittings and Tools are
not designed to work with common commercial instrument tubing
Autoclave Engineers Operation Instrumentation Products Division, Europe
and will only work with tubing built to Parker Autoclave Engineers
8325 Hessinger Drive Industrial Estate Whitemill AES Specifications. Failure to do so will void warranty.
Erie, Pennsylvania 16509-4679 USA Wexford, Republic of Ireland
PH: 814-860-5700 FAX: 814-860-5811 PH: 353 53 914 1566
www.autoclave.com FAX: 353 53 914 1582 ISO-9001 Certified
Needle Valves - Wellhead Gauge and Bleed Valves
Pressures to 30,000 psi (2068 bar)
Bleed Valve
20BV 3/8 SM375CX 0.093 (2.36) - 20,000 (1379)
20BV 9/16 SM562CX 0.093 (2.36) - 20,000 (1379)
30BV 9/16 M562C 0.093 (2.36) - 30,000 (2068)*
Notes:
* Rating shown is in closed position.
Rating @ 15,000 psi (1034 bar) in open position. Glands and collars included
Parker Autoclave Engineers Wellhead Gauge valves are Gauge Valve Features:
designed for reliable shut-off service at a maximum work- One inlet, three outlet ports
ing pressure of 30,000 psi (2068 bar). The Wellhead Gauge Metal-to-metal bubble tight shut-off
and Bleed Valves are standard in 316 stainless steel material. Packing below stem threads
Special materials available on request. Two piece non-rotating stem on standard valves
Ordering Procedure
Typical catalog number: 30GV9078
30GV 9 07 8
Valve Outside Diameter Stem Body
Series Tube Size Type Pattern
20GV 6-3/8 00 - one piece VEE stem 8 - 4 ports, 1 inlet, 3 outlets
30GV 9-9/16 07- non-rotating VEE stem
Bleed Valve
Typical catalog number: 30BV9002
30BV 9 00 2
Valve Outside Diameter Stem Body
Series Tube Size Type Pattern
20BV 6-3/8 00 - one piece VEE stem 2 -Angle
30BV 9-9/16
Wellhead Gauge Valve
SF375CX 3/8 20,000 2.00 3.12 2.00 4.52 1.13 1.00 0.50 0.94 3.00
20GV6078
(1379) (50.80) (79.25) (50.80) (114.80) (28.58) (25.40) (12.70) (23.83) (76.20)
SF562CX 9/16 20,000 2.00 3.88 2.75 4.54 1.31 1.38 0.66 0.94 3.00 See
20GV9078
(1379) (50.80) (98.55) (69.85) (115.31) (33.27) (34.93) (16.76) (23.83) (76.20) Figure 1
F562C 9/16 30,000 2.00 3.88 2.75 4.50 1.31 1.38 0.66 0.94 3.00
30GV9078
(2068) (50.80) (98.55) (69.85) (114.30) (33.27) (34.93) (16.76) (23.83) (76.20)
J
Mounting Dimensions
K L M Dia.
20GV6078 .25 (6.4) .25 (6.4) .28 (7.1)
20GV9078 .38 (9.7) .38 (9.7) .28 (7.1)
D K 30GV9078 .38 (9.7) .38 (9.7) .28 (7.1)
"M" L
A
H
G
F
E
C B Figure 1 - Wellhead Gauge Valve
Bleed Valve
WARNING
FAILURE, IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS AND/OR SYSTEMS DESCRIBED HEREIN OR RELATED ITEMS CAN CAUSE DEATH, PERSONAL INJURY AND PROPERTY DAMAGE.
This document and other information from Parker Hannifin Corporation, its subsidiaries and authorized distributors provide product and/or system options for further investigation by users having technical
expertise. It is important that you analyze all aspects of your application and review the information concerning the product or system in the current product catalog. Due to the variety of operating conditions
and applications for these products or systems, the user, through its own analysis and testing, is solely responsible for making the final selection of the products and systems and assuring that all performance,
safety and warning requirements of the application are met. The products described herein, including without limitation, product features, specifications, designs, availability and pricing, are subject to change by
Parker Hannifin Corporation and its subsidiaries at any time without notice.
Offer of Sale
The items described in this document are available for sale by Parker Hannifin Corporation, its subsidiaries or its authorized distributors. Any sale contract entered by Parker will be governed by the provisions
stated in Parker's standard terms and conditions of sale (copy available upon request).
2013 Parker Hannifin Corporation | Autoclave Engineers is a registered trademark of the Parker Hannifin Corporation 02-1250SE January2013
Instrumentation Products Division Parker Hannifin Manufacturing Ltd. Caution! Parker Autoclave Engineers Valves, Fittings and Tools are
not designed to work with common commercial instrument tubing
Autoclave Engineers Operation Instrumentation Products Division, Europe
and will only work with tubing built to Parker Autoclave Engineers
8325 Hessinger Drive Industrial Estate Whitemill AES Specifications. Failure to do so will void warranty.
Erie, Pennsylvania 16509-4679 USA Wexford, Republic of Ireland
PH: 814-860-5700 FAX: 814-860-5811 PH: 353 53 914 1566
www.autoclave.com FAX: 353 53 914 1582 ISO-9001 Certified
Needle Valves
Extreme Temperature
www.autoclave.com
Needle Valve - HT, LT Series
Standard Valve with Stuffing Box option - Pressures to 60,000 psi (4137 bar)
2 All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold.
Needle Valve - PV Series
Pressures to 6,000 psi (414 bar)
Pressure
Rating
Tube psi (bar)
Outside Connection Orifice @ Room
Diameter Type Size Temperature**
TW - Tube Weld
PW - Pipe Weld
Note: ** For temperature ratings see pressure/temperature rating guide
chart below..
POWDER COATED
STAINLESS STEEL
PACKING GLAND HANDLE
ANTI-EXTRUSION
BACK-UP RINGS ADJUSTABLE PACKING
BELOW THREADS
INLET OUTLET
CHOICE OF VEE OR
REGULATING STEM TIP METAL-TO-METAL WELDED CONNECTION
SEATING
Ordering Procedure
For complete information on available stem types, optional connections and additional valve options, see Needle Valve Options section or contact
your Sales Representative.
PV 4 TW Outlet
See Note
6M G
Valve Outside Diameter Connection Size/Type Port Packing
Series Tube Size Type Size
4-1/4 TW - Tube Socket Weld 3 -3/16 G - Graphic Yarn
6-3/8
PW - Pipe Socket Weld 4 -1/4 GF - Grafoil
8-1/2
12- 3/4 8 -1/2
A-10mm 6M - 6.5mm
B-12mm
C-14mm 9M - 9.0mm
D-16mm 11M - 11.0mm
2-Way Straight
1/4 0.187 2.00 1.00 1.41 1.41 2.00 3.00 0.75 0.22 4.43 0.62 0.38 0.75
PV4TW3G VEE
(6.35) (4.75) (50.80) (25.40) (35.81) (35.81) (50.80) (76.20) (19.05) (5.59) (112.52) (15.75) (9.65) (19.05)
PVT6TW4G VEE 3/8 0.250 2.00 1.00 1.41 1.41 2.00 3.00 0.75 0.22 4.43 0.62 0.38 0.75
(9.53) (6.35) (50.80) (25.40) (35.81) (35.81) (50.80) (76.20) (19.05) (5.59) (112.52) (15.75) (9.65) (19.05) See
Metric (In) Figure 1
PVCTW6MG VEE 14.00 6.5 50.80 25.40 35.81 35.81 50.80 76.20 19.05 5.59 111.00 15.75 9.65 19.05
(0.55) (0.26) (2.00) (1.00) (1.41) (1.41) (2.00) (3.00) (0.75) (0.22) (4.37) (0.62) (0.38) (0.75)
PVCTW9MG VEE 14.00 9.0 63.50 31.75 52.32 52.32 73.15 101.60 22.23 5.59 148.34 17.53 12.70 25.40
(0.55) (0.35) (2.50) (1.25) (2.06) (2.06) (2.88) (4.00) (0.88) (0.22) (5.84) (0.69) (0.50) (1.00)
G - Packing gland mounting hole drill size * H Dimension is with stem in closed position. For prompt service, Parker
G1 - Bracket mounting hole size All dimensions for reference only and subject to change. Autoclave Engineers stocks select
Panel mounting drill size: 0.22 all valves. products. Consult factory.
Figure 1
F
G1
M M
G
H N
D D1
E
B
A
2-Way Straight
WARNING
FAILURE, IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS AND/OR SYSTEMS DESCRIBED HEREIN OR RELATED ITEMS CAN CAUSE DEATH, PERSONAL INJURY AND PROPERTY DAMAGE.
This document and other information from Parker Hannifin Corporation, its subsidiaries and authorized distributors provide product and/or system options for further investigation by users having technical
expertise. It is important that you analyze all aspects of your application and review the information concerning the product or system in the current product catalog. Due to the variety of operating conditions
and applications for these products or systems, the user, through its own analysis and testing, is solely responsible for making the final selection of the products and systems and assuring that all performance,
safety and warning requirements of the application are met. The products described herein, including without limitation, product features, specifications, designs, availability and pricing, are subject to change by
Parker Hannifin Corporation and its subsidiaries at any time without notice.
Offer of Sale
The items described in this document are available for sale by Parker Hannifin Corporation, its subsidiaries or its authorized distributors. Any sale contract entered by Parker will be governed by the provisions
stated in Parker's standard terms and conditions of sale (copy available upon request).
2013 Parker Hannifin Corporation | Autoclave Engineers is a registered trademark of the Parker Hannifin Corporation 02-0117SE January2013
20DV Series
Pressures to 20,000 psi (1379 bar)
www.autoclave.com
Valve Series - 20DV Series
Pressures to 20,000 psi (1379 bar)
Tube
Outside Pressure
Diameter Orifice psi (bar)
Size Connection Size Rated @ Room
Inches Type Inches (mm) Cv Temperature**
Notes:
STAINLESS STEEL
TEE HANDLE
(1" & 3/4" MODELS Generalized Flow Coefficient Curves (Cv)
ALUMINUM BRONZE
ONLY) 8
PACKING GLAND
ADJUSTABLE 5
PACKING BELOW NON-ROTATING
THREADS STEM
4
3
UPPER VEE STEM
2
SLIMLINE CONED AND
THREADED 1 Diverter Valve
CONNECTIONS
LOWER STEM
0
10 20 30 40 50 60 70 80 90 100
% of rated Cv
Ordering Procedure
For complete information on available stem types, optional connections and additional valve options, see Needle Valve Options section or contact
your Sales Representative. The 20DV Series valves are furnished complete with connection components, unless otherwise specified.
20DV 16 07 7 XX
Valve Outside Diameter Stem Body Options
Series Tube Size Type Pattern
7 - diverter For extreme
9-9/16 07 - non-rotating
temperature and other
12-3/4 Vee stem (on off service)
options, see
16-1
Valve Options.
2 All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold.
Valve Options Valve Maintenance
Extreme Temperatures Repair Kits: add R to the front of valve catalog
Standard Parker Autoclave Engineers valves with PTFE packing may number for proper repair kit.
be operated to 450F (232C). High temperature packing and/or (Example: R20DV16077)
extended stuffing box is available for service from -423F (-252C) Valve Bodies: Valve bodies are available. Order using the eight (8)
to 1200F (649C) by adding the following suffixes to catalog order digit part number found on the valve drawing or
number. contact your Sales Representative for information.
HT extended stuffing box valve with graphite braided yarn packing Consult your Parker Autoclave Engineers representative for pricing on repair
to 1200F (648C). kits and valve bodies. Refer to the Tools, Installation, Operation and Mainte-
B standard valve with cryogenic trim materials and PTFE packing to nance section for proper maintenance procedures.
-100F (-73C).
LT extended stuffing box valve with PTFE packing and cryogenic trim
materials to -423F (-252C).
K anti-vibe collet gland assembly.
20DV9077 VEE 9/16 0.359 2.50 1.25 0.53 2.41 1.75/1.63 4.69 4.00 1.00 0.34 8.88 0.69 0.50 1.00
(14.29) (9.12) (63.50) (31.75) (13.46) (61.21) (44.45/41.40) (119.13) (101.60) (25.40) (8.64) (225.55) (17.53) (12.70) (25.40)
20DV12077 VEE 3/4 0.516 3.00 1.50 0.62 3.00 2.13/1.81 5.69 10.25 1.12 0.44 10.12 0.88 0.62 1.38 See
(19.05) (13.11) (76.20) (38.10) (15.75) (76.20) (54.10/45.97) (144.53) (260.35) (28.45) (11.18) (257.05) (22.35) (15.75) (35.05) Figure 1
20DV16077 VEE 1 0.562 4.12 2.06 0.72 3.75 2.81/2.62 7.25 10.25 1.62 0.56 12.79 1.25 1.12 1.75
(25.40) (14.27) (104.65) (52.33) (18.29) (95.25) (71.37/66.55) (184.15) (260.35) (41.15) (14.22) (324.87) (31.75) (28.45) (44.45)
G - Packing gland mounting hole drill size * H Dimension is with stem in closed position. For prompt service, Parker
G1 - Bracket mounting hole size All dimensions for reference only and subject to change. Autoclave Engineers stocks select
Panel mounting drill size: 0.22 all valves. products. Consult factory.
Figure 1
F
G1
M M
H
N G
D1
D
E
D1
N B C
A
Diverter 20DV Series
All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold. 3
WARNING
FAILURE, IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS AND/OR SYSTEMS DESCRIBED HEREIN OR RELATED ITEMS CAN CAUSE DEATH, PERSONAL INJURY AND PROPERTY DAMAGE.
This document and other information from Parker Hannifin Corporation, its subsidiaries and authorized distributors provide product and/or system options for further investigation by users having technical
expertise. It is important that you analyze all aspects of your application and review the information concerning the product or system in the current product catalog. Due to the variety of operating conditions
and applications for these products or systems, the user, through its own analysis and testing, is solely responsible for making the final selection of the products and systems and assuring that all performance,
safety and warning requirements of the application are met. The products described herein, including without limitation, product features, specifications, designs, availability and pricing, are subject to change by
Parker Hannifin Corporation and its subsidiaries at any time without notice.
Offer of Sale
The items described in this document are available for sale by Parker Hannifin Corporation, its subsidiaries or its authorized distributors. Any sale contract entered by Parker will be governed by the provisions
stated in Parker's standard terms and conditions of sale (copy available upon request).
2013 Parker Hannifin Corporation | Autoclave Engineers is a registered trademark of the Parker Hannifin Corporation 02-0118SE January2013
Instrumentation Products Division Parker Hannifin Manufacturing Ltd. Caution! Parker Autoclave Engineers Valves, Fittings and Tools are
Autoclave Engineers Operation Instrumentation Products Division, Europe not designed to work with common commercial instrument tubing
and will only work with tubing built to Parker Autoclave Engineers
8325 Hessinger Drive Industrial Estate Whitemill
AES Specifications. Failure to do so will void warranty.
Erie, Pennsylvania 16509-4679 USA Wexford, Republic of Ireland
PH: 814-860-5700 FAX: 814-860-5811 PH: 353 53 914 1566
www.autoclave.com FAX: 353 53 914 1582 ISO-9001 Certified
Needle Valves
Yoke
Y Series
Pressures to 50,000 psi (3447 bar)
www.autoclave.com
Valve Series - Y Series
Pressures to 50,000 psi (3447 bar)
Tube
Outside Pressure
Diameter Orifice psi (bar)
Size Connection Size Rated @ Room
Inches Type Inches (mm) Cv * Temperature**
Notes:
* CV values shown are for 2-way straight valve pattern. For 2-way
angle patterns, increase CV value 50%.
STAINLESS STEEL
TEE HANDLE Generalized Flow Coefficient Curves (Cv)
(except 9/16 replaceable seat)
7
6
NON-ROTATING
Number of turns open
STEM
PACKING GLAND 5 15Y & 43Y
TYPE 316 SS Vee Stem
BONNET
COLD WORKED 4
TYPE 316 SS 15Y & 43Y
BODY
Regulating Stem
3
ADJUSTABLE 50Y Regulating
PACKING BELOW Stem
THREADS 2
0
AE MEDIUM PRESSURE
CONED-AND-THREADED CONNECTIONS ON
10 20 30 40 50 60 70 80 90 100
SERIES 15Y, AE HIGH PRESSURE ON 50Y AND
% of rated Cv
50Y 9 07 1 XX
Valve Outside Diameter Stem/Seat Body Options
Series Tube Size Type Pattern
9-9/16 07 - non-rotating TG - PTFE Glass
15Y 1 - two-way straight
12-3/4 Packing
43Y Vee stem (on-off service) 2 - two-way angle
50Y 16-1.0 B - Cryogenic
08 - non-rotating Trim and PTFE
Regulating stem (tapered tip for Packing
Regulating and shutoff) See Valve options
87 - Vee stem with replaceable seat for ratings
2 All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold.
Valve Options Valve Maintenance
Extreme Temperatures Repair Kits: add R to the front of valve catalog
Standard Parker Autoclave Engineers valves with PTFE packing may number for proper repair kit.
be operated to 450F (232C). High temperature packing is available (Example: R50Y9071)
for service from 0F (-17.8C) to 600F (316C) by adding the follow- Valve Bodies: Valve bodies are available. Order using the eight (8)
ing suffixes to catalog order number. digit part number found on the valve drawing or
TG standard valve with PTFE glass packing to 600F (316C). contact your Sales Representative for information.
B standard valve with cryogenic trim materials and PTFE packing to Consult your Parker Autoclave Engineers representative for pricing on repair
-100F (-73C). kits and valve bodies. Refer to the Tools, Installation, Operation and Mainte-
nance section for proper maintenance procedures.
2-Way Straight
15Y12071 VEE 3/4 0.438 3.00 1.50 0.63 .75 1.50 3.50 8.00 0.28 9.38 1.13 0.88 1.38
15Y12081 REG (19.05) (11.13) (76.20) (38.10) (15.88) (19.05) (38.10) (88.90) (203.20) (7.11) (238.25) (28.58) (22.23) (34.93)
15Y16071 VEE 1.00 0.562 4.13 2.06 0.63 .88 1.88 4.13 10.25 0.28 10.00 1.50 1.13 1.75
15Y16081 REG (25.40) (14.27) (104.78) (52.39) (15.88) (22.35) (47.75) (104.78) (260.35) (7.11) (254.00) (38.10) (28.58) (44.45) See
43Y16071 VEE 1.00 0.375 4.13 2.07 0.72 1.00 1.88 4.13 10.25 0.28 9.56 1.50 1.00 1.75 Figure 1
43Y16081 REG (25.40) (9.53) (104.90) (52.45) (18.29) (25.40) (47.75) (104.78) (260.35) (7.11) (242.82) (38.10) (25.40) (44.45)
50Y9071 VEE 9/16 0.188 3.00 1.50 0.56 .688 1.25 3.25 13.00 0.50 8.69 1.13 0.88 1.38
50Y9081 REG (14.27) (4.78) (76.20) (38.10) (14.27) (17.48) (31.75) (82.55) (330.20) (12.70) (220.73) (28.58) (22.23) (34.93)
2-Way Angle
15Y12072 VEE 3/4 0.438 3.00 1.50 0.63 1.75 3.75 8.00 0.28 9.63 1.13 0.88 1.38
15Y12082 REG (19.05) (11.13) (76.20) (38.10) (15.88) (44.45) (95.25) (203.20) (7.11) (244.48) (28.58) (22.23) (34.93)
15Y16072 VEE 1.00 0.562 4.13 2.06 0.63 2.25 4.50 10.25 0.28 10.38 1.50 1.13 1.75
15Y16082 REG (25.40) (14.27) (104.90) (52.39) (15.88) (57.15) (114.30) (260.35) (7.11) (263.53) (38.10) (28.58) (44.45) See
43Y16072 VEE 1.00 0.375 4.13 2.07 0.72 2.31 4.56 10.25 0.28 10.80 1.50 1.00 1.75 Figure 2
43Y16082 REG (25.40) (9.53) (104.90) (52.45) (18.29) (58.67) (115.82) (260.35) (7.11) (274.32) (38.10) (25.40) (44.45)
50Y9072 VEE 9/16 0.188 3.00 1.50 0.56 1.50 3.50 13.00 0.50 8.81 1.13 0.88 1.38
50Y9082 REG (14.27) (4.78) (76.20) (38.10) (14.27) (38.10) (88.90) (330.20) (12.70) (223.82) (28.58) (22.23) (34.93)
G - Bracket mounting hole size * H Dimension is with stem in closed position. For prompt service, Parker Autoclave
All dimensions for reference only and subject to change. Engineers stocks select products.
Consult factory.
H H
H G1
G1 N
G1 N
N
D E
D E
D1 E
D
B C
M M B C B C
A M M M M
A A
All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold. 3
WARNING
FAILURE, IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS AND/OR SYSTEMS DESCRIBED HEREIN OR RELATED ITEMS CAN CAUSE DEATH, PERSONAL INJURY AND PROPERTY DAMAGE.
This document and other information from Parker Hannifin Corporation, its subsidiaries and authorized distributors provide product and/or system options for further investigation by users having technical
expertise. It is important that you analyze all aspects of your application and review the information concerning the product or system in the current product catalog. Due to the variety of operating conditions
and applications for these products or systems, the user, through its own analysis and testing, is solely responsible for making the final selection of the products and systems and assuring that all performance,
safety and warning requirements of the application are met. The products described herein, including without limitation, product features, specifications, designs, availability and pricing, are subject to change by
Parker Hannifin Corporation and its subsidiaries at any time without notice.
Offer of Sale
The items described in this document are available for sale by Parker Hannifin Corporation, its subsidiaries or its authorized distributors. Any sale contract entered by Parker will be governed by the provisions
stated in Parker's standard terms and conditions of sale (copy available upon request).
2013 Parker Hannifin Corporation | Autoclave Engineers is a registered trademark of the Parker Hannifin Corporation 02-0119SE January2013
Instrumentation Products Division Parker Hannifin Manufacturing Ltd. Caution! Parker Autoclave Engineers Valves, Fittings and Tools are
not designed to work with common commercial instrument tubing
Autoclave Engineers Operation Instrumentation Products Division, Europe
and will only work with tubing built to Parker Autoclave Engineers
8325 Hessinger Drive Industrial Estate Whitemill AES Specifications. Failure to do so will void warranty.
Erie, Pennsylvania 16509-4679 USA Wexford, Republic of Ireland
PH: 814-860-5700 FAX: 814-860-5811 PH: 353 53 914 1566
www.autoclave.com FAX: 353 53 914 1582 ISO-9001 Certified
Needle Valves
Options
Parker Autoclave Engineers Needle Valves can be
supplied with a number of options to meet your
requirements. These include various materials of
construction, packing material, high temperature
packing, handle colors, stem options, custom
valves, pneumatic actuators, and a number of other
options.
www.autoclave.com
Needle Valves - Stem Options
Three Stem Types
Three types of stems are offered by Parker Autoclave Engineers: Vee, Regulating and MicroMetering. Both
Vee and Regulating stems are interchangable on most Parker AE valves and provide bubble-tight shut-off
against liquids and gases.
Optional Materials
To order optional materials for wetted parts, add the following designations to the order number.
Packing Options
Refer to the valve model required, and see valve options in that section.
Optional Connections
In addition to standard tube connections, Parker Autoclave Engineers can supply many valve and fitting
series with such optional end connections as Female or Male NPT, Socket Weld to O.D. tube size, or nominal
pipe size, Female AN (MS 33649), Male AN (MS 33656), Butt Weld and British straight thread. Contact
factory for current information. Metric sizes can be supplied on most Parker Autoclave Engineers valves and
fittings on special order.
Anti-Vibration Adder
For valves or other components supplied with anti-vibration option, add -K to catalog number. See fitting
and tubing sections for anti-vibration information.
Stem and Handle Extenders
Stem Extenders are offered for high or low temperature operation
on most Parker Autoclave Engineers valves. They are also useful for
"ES"
remote actuation, such as behind a barricade. To order any valve with Specify desired
a Stem Extender, add ES and the length (6, 12, 18 or 24) to the extra length
in inches
beginning of the valve catalog number: e.g. ES12-30VM4071. Other
lengths on special order. To order stem extender only, please provide
extender number and the prefix of the valve model. Ex: ES12-20SM6 (handle not included.)
Abrasive or Highly Erosive Service Option
For service conditions where high flows, erosive mediums, or high pressures cause premature wear on
stems and seats, N-Dura coating can be supplied to increase component life.
N-Dura coating is specifically used to enhance stem and seat life by providing a protective coating over a
base substrate. This creates a thin, hard, protective coating with no effects of brittleness. The coating will
not peel, chip or flake off the base material. The coating hardness is in a range of minimum 85 Rc
surpassing other coatings and most materials.
The additional performance characteristics provided with the coating are reduced friction, corrosion resis-
tance exceeding 400 stainless steel, and operating temperature ranges from -300F to 1200F.
The coating has been tested in erosive applications, yielding far better results than Stellite, which has been
utilized extensively in these applications. With few exceptions, most major ferrous and non ferrous materials
can be successfully coated.
Most valves in this catalog are available with N-Dura coated stems or with both N-Dura coated stems and
replaceable seats. This coating is available for all stem options. To order both N-Dura stems on any valve
pattern, add suffix CS to the catalog model number. To order both N-Dura coated stems and N-Dura
coated replaceable seats (available on 2-way angle replaceable seat pattern only) add suffix CSS to the
catalog number. Stellite is available as a special upon request.
Optional Valve Handles
Blue powder coated stainless handles are standard on the majority of the valve series. Stainess handles can
be purchased in different colors if required, contact the factory for color options.
All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold. 3
Exception: Heavy-duty Stainless Steel T-handles assemblies are standard on our larger valves, see
detailed information on each section for handles used.
Panel Mounting
Most Parker Autoclave Engineers valve series can be panel mounted through the locking device screw hole
and a corresponding hole opposite the packing gland. To order a set of two panel mounting screws, add PM
to the catalog order number.
Handle Lockouts: Handle lockouts are available to lockout valves in the open or closed position preventing
unauthorized personnel from actuating valves during shutdowns or emergency situations. Lockouts consist
of two halves that completely cover the valve handle and can be locked for security. They are constructed of
durable plastic resistant to abrasion, solvents, and chemical agents. Consult factory for details.
To order lockouts with valves add -L to part number.
Lockout part numbers: 90088 - 2.5" (63.5) to 5.0" (127.0) handle size
90194 - 6.5" (165.1) to 10.0" (254.0) handle size
Note: Modifications may be required to some valves to use lockouts if purchased separately. See page 1 of
ball valve options for photo of clamp style lockout.
Note: Many standard and special options and accessories for Parker Autoclave Engineers valves are listed
here. Not all options apply to all valve series - see individual ordering pages for specifics. Some options
listed here are special order options with prices quoted on application. See Custom Valves/Manifolds section
for other options.
For prompt service, Parker Autoclave Engineers stocks select products. Consult your local representative.
WARNING
FAILURE, IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS AND/OR SYSTEMS DESCRIBED HEREIN OR RELATED ITEMS CAN CAUSE DEATH, PERSONAL INJURY AND PROPERTY DAMAGE.
This document and other information from Parker Hannifin Corporation, its subsidiaries and authorized distributors provide product and/or system options for further investigation by users having technical
expertise. It is important that you analyze all aspects of your application and review the information concerning the product or system in the current product catalog. Due to the variety of operating conditions
and applications for these products or systems, the user, through its own analysis and testing, is solely responsible for making the final selection of the products and systems and assuring that all performance,
safety and warning requirements of the application are met. The products described herein, including without limitation, product features, specifications, designs, availability and pricing, are subject to change by
Parker Hannifin Corporation and its subsidiaries at any time without notice.
Offer of Sale
The items described in this document are available for sale by Parker Hannifin Corporation, its subsidiaries or its authorized distributors. Any sale contract entered by Parker will be governed by the provisions
stated in Parker's standard terms and conditions of sale (copy available upon request).
2013 Parker Hannifin Corporation | Autoclave Engineers is a registered trademark of the Parker Hannifin Corporation 02-0120SE January2013
Caution! Parker Autoclave Engineers Valves, Fittings and Tools are not
Instrumentation Products Division Parker Hannifin Manufacturing Ltd.
designed to work with common commercial instrument tubing and will
Autoclave Engineers Operation Instrumentation Products Division, Europe only work with tubing built to Parker Autoclave Engineers Specifications
8325 Hessinger Drive Industrial Estate Whitemill AES-222. Failure to do so will void warranty.
Erie, Pennsylvania 16509-4679 USA Wexford, Republic of Ireland
PH: 814-860-5700 FAX: 814-860-5811 PH: 353 53 914 1566
www.autoclave.com FAX: 353 53 914 1582 ISO-9001 Certified
Pneumatic
Valve Actuator
Pressures to 150,000 psi (10342 bar)
Actuator - Pneumatic
www.autoclave.com
Pneumatic Valve Actuators - General information
Pressures to 150,000 psi (10342 bar)
Pneumatic Actuator
Pressures to 150,000 psi (10342 bar)
Manual electric switch or
instrument for remote operation
Six sizes of air operators (light, heavy light, medium, heavy
Solenoid Valve
duty or extra heavy, single and double stage) are offered for
remote on-off operation or automatic operation of Parker
Air-in
Autoclave Engineers low, medium or high pressure valves.
AOV
The actuators are available in air-to-open (normally closed) and Vent
air-to-close (normally open) designs.
To order a valve with an air operator, select the duty rating Medium
Air-to-close CM
and type of the air operator from the chart below. Add the air Air-to-open O1S
Piston
operator identifying suffix to the catalog number of the Parker Air-to-close C1S
Autoclave Engineers valve. To order a 2-way straight, 30VM vee Air-to-open OH
Diaphragm
stem, 9/16 valve with a medium duty air-to-close air operator, Air-to-close CH
specify: ex: 30VM9071-C1S for a yoke style piston air actu- Heavy
Air-to-open O2S
ated valve or 30VM9071-CM for an integral style diaphragm air Piston
Air-to-close C2S
operated valve.
Extra Heavy Air-to-open HO1S
To order the same valve with an extended high temperature Single Stage
Piston
Air-to-close HC1S
stuffing box, add HT to the ordering number: ex: 30VM9071-
Extra Heavy Air-to-open HO2S
C1SHT or 30VM9071-CMHT. Double Stage
Piston
Air-to-close HC2S
To order a dual air operator manifold valve, specify both Outdoor Service Actuators
operators if different. The same valve with a medium duty ATC
Air-to-open O1SOD
on one stem and a medium duty ATO on the other, specify: Medium Piston
Air-to-close C1SOD
ex: 30VM9075-C1SO1S.
Air-to-open O2SOD
To order a valve with operators for outdoor service add an Heavy Piston
Air-to-close C2SOD
OD suffix to the catalog number.
Extra Heavy Air-to-open HO1SOD
Piston
Single Stage Air-to-close HC1SOD
Note: Ordering air actuated valves models with regulating
stems is not recommend. These are open/close actuators and Extra Heavy
Piston
Air-to-open HO2SOD
Doubl Stage
will not regulate flow. Air-to-close HC2SOD
2
Pneumatic Valve Actuators - Actuator Quick Selector Guide
This table allows the designer to quickly select an appropriate air available air pressure is 60 psi (4.14 bar) and an air-to-open (spring
actuator based on valve style and size, maximum system operating fail closed) valve is required, a 30VM or 60VM valve with a heavy
pressure and maximum available air pressure. For example, if the duty air operator can be used. More specific sizing data is available in
system operating pressure is 25,000 psi (1724 bar) and the the sizing charts on the following pages.
Air-to-Close
Light Medium Heavy Extra Heavy Extra Heavy
Valve Single Stage Two Stage
Tube
Series
Outside System Air System Air System Air System Air System Air
Diameter Pressure Pressure Pressure Pressure Pressure Pressure Pressure Pressure Pressure Pressure
in (mm) psi (bar) psi (bar) psi (bar) psi (bar) psi (bar) psi (bar) psi (bar) psi (bar) psi (bar) psi (bar)
1/2 10,000 65
(12.70) (689.46) (4.48)
1/4 15,000 65
(6.35) (1034.20) (4.48)
NOTE: For 10P and 15P series pipe valves see sizing data tables.
3
Pneumatic Valve Actuators - Actuator Quick Selector Guide
Air-to-Open
Light Medium Heavy Extra Heavy Extra Heavy
Valve Single Stage Two Stage
Tube
Series
Outside System Air System Air System Air System Air System Air
Diameter Pressure Pressure Pressure Pressure Pressure Pressure Pressure Pressure Pressure Pressure
in (mm) psi (bar) psi (bar) psi (bar) psi (bar) psi (bar) psi (bar) psi (bar) psi (bar) psi (bar) psi (bar)
1/2 10,000 95
(12.70) (689.46) (6.55)
4
Pneumatic Valve Actuators - Actuator Quick Selector Guide
Air-to-Close Air-to-Open
Light Medium Heavy Extra Heavy Light Medium Heavy Extra Heavy
Valve Two Stage Two Stage
Tube
Series Outside System Air System Air System Air System Air System Air System Air System Air System Air
Diameter Pressure Pressure Pressure Pressure Pressure Pressure Pressure Pressure Pressure Pressure Pressure Pressure Pressure Pressure Pressure Pressure
in (mm) psi (bar) psi (bar) psi (bar) psi (bar) psi (bar) psi (bar) psi (bar) psi (bar) psi (bar) psi (bar) psi (bar) psi (bar) psi (bar) psi (bar) psi (bar) psi (bar)
1 30,000 80 30,000 80
30SC (25.40) (2068.39) (5.52) (2068.39) (5.52)
5
Pneumatic Valve Actuators - Piston Style Pneumatic
Pressures to 150,000 psi (10342 bar)
Parker Autoclave Engineers piston type actuators feature: Air Operator Materials
Small, compact, piston actuator Cylinder, piston, cover plates, spring housing
Air-to-open or -close with spring return Anodized aluminum (for corrosion and wear resistance).
Yoke design for separation of process and air pressure Yoke
Ease of stem replacement Painted Steel
Stem position indicator is standard Technical Data
Positive shut-off metal-to-metal seating Air Operator
High actuator cycle life Maximum allowable working pressure: 100 psi (6.89 bar)
1/8" NPT air inlet connection except Extra Allowable piston temperature range: -20F to 200F
Heavy duty has 3/8" NPT (-29C to 93C)
Area of piston:
B Light duty - 4.9 sq. in (31.6 sq. cm)
Mini-Light duty - 5.4 sq. in (34.8 sq. cm)
Medium duty - 19.6 sq. in (126.5 sq. cm)
Heavy duty - 39.2 sq. in (252.9 sq. cm)
Extra Heavy duty single stage - 56 sq. in (361.3 sq. cm)
Extra Heavy duty double stage - 112 sq. in (722.6 sq. cm)
Approximate air usage/cycle @ 100 psi (6.89 bar):
Light duty - .003 SCF (.00008 SCM)
Mini-Light duty - .007 SCF (.0002 SCM)
A Medium duty - .04 SCF (.0011 SCM)
Heavy duty - .08 SCF (.0022 SCM)
Extra Heavy duty single stage - .33 SCF (.0095 SCM)
Holes supplied in yoke Extra Heavy duty double stage - .67 SCF (.019 SCM)
bracket for mounting
Tested to 100,000 cycles at 100 psi (6.89 bar) with no
leakage or signs of wear or fatigue.
6.42 7.12
Air-to-open OM
(163.01) (180.90)
B Medium
3.75 7.12
Air-to-close CM (95.25) (180.90)
8.75 10.00
A Air-to-open OH (222.25) (254.00)
Heavy
4.69 10.00
Air-to-close CH (119.13) (254.00)
Air-to-Close (ATC)
7
Pneumatic Valve Actuators - Air Operator Sizing Data
Air-to-Close
Series 10V and SW Valves
Valve Maximum Stem Travel Flow
Series Operator Duty System Pressure KSI (Mpa) Pressure
in (mm) Coefficient**
psi (bar)*
1-4 6 8 10 12 14 15
(6.89-27.57) (41.37) (55.16) (68.95) (82.74) (96.53) (103.42)
30 40 55 65 85 95 100 15,000 0.16 0.12
Light Duty
(2.07) (2.76) (3.79) (4.48) (5.86) (6.55) (6.89) (1034.20) (4.06)
10V2
25 25 25 25 25 25 30
Medium Duty (1.72) (1.72) (1.72) (1.72) (1.72) (1.72) (2.07)
20SM12 Extra
30 30 40 50 60 65 75 85 95 100 19,000
10P12 Heavy Duty
(2.07) (2.07) (2.76) (3.45) (4.13) (4.48) (5.17) (5.86) (6.55) (6.89) (1310.00)
Single Stage
Extra 15 15 20 25 30 35 40 45 50 50 20,000
Heavy Duty (1.03) (1.03) (1.38) (1.72) (2.07) (2.41) (2.76) (3.10) (3.45) (3.45) (1378.93)
Two Stage
100 100 3,900 0.56 3.40
Medium Duty
(6.89) (6.89) (268.89) (14.22)
50 50 70 100 8,800
Heavy Duty
(3.45) (3.45) (4.83) (6.89) (606.73)
20SM16 Extra
40 40 55 70 85 100 12,500
10P16 Heavy Duty
(2.76) (2.76) (3.79) (4.83) (5.86) (6.89) (861.83)
Single Stage
Extra 20 20 25 35 40 50 55 60 70 75 20,000
Heavy Duty (1.38) (1.38) (1.72) (2.41) (2.76) (3.45) (3.79) (4.48) (4.83) (5.17) (1378.93)
Two Stage
Extra Air
30 40 45 50 55 60 65 70 75 80 30,000 0.50 2.61
30SC16 Heavy Duty Pressure
(2.07) (2.76) (3.10) (3.45) (3.79) (4.13) (4.48) (4.83) (5.17) (5.52) (2068.39) (12.70)
Two Stage psi (bar)
** Cv data is for 2-way straight valves. CAUTION: While testing has shown O-rings to provide satisfactory service life,
For angle pattern, add approximately 50% to the CV valve. both cyclic and shelf life may vary widely with differing service conditions,
properties of reactants, pressure and temperature cycling and age of the O-ring,
FREQUENT INSPECTIONS SHOULD BE MADE to detect any deterioration, and
O-rings replaced as required.
9
Air-to-Close - Series 30VM Valves
Valve Maximum Stem Travel Flow
Series Operator Duty System Pressure KSI (Mpa) Pressure
in (mm) Coefficient**
psi (bar)*
1-10 12 14 16 18 20 22 24 26 28 30
(6.89-68.94) (82.74) (96.53) (110.31) (124.10) (137.89) (151.68) (165.47) (179.26) (193.05) (206.84)
25 25 25 30 35 35 40 45 50 50 55 30,000 0.19 0.12
Medium Duty (1.72) (1.72) (1.72) (2.07) (2.41) (2.41) (2.76) (3.10) (3.45) (3.45) (3.79) (2068.39) (4.83)
30VM4
15 15 15 15 20 20 20 25 25 25 30
Heavy Duty Air (1.03) (1.03) (1.03) (1.03) (1.38) (1.38) (1.38) (1.72) (1.72) (1.72) (2.07)
Pressure
psi (bar) 30 30 35 40 45 50 55 60 65 70 75 30,000 0.19 0.23
30VM6 Medium Duty
(2.07) (2.07) (2.41) (2.76) (3.10) (3.45) (3.79) (4.13) (4.48) (4.83) (5.17) (2068.39) (4.83) (30VM6)
&
30VM9 15 15 20 20 25 25 30 30 35 35 40 0.33
Heavy Duty
(1.03) (1.03) (1.38) (1.38) (1.72) (1.72) (2.07) (2.07) (2.41) (2.41) (2.76) (30VM9)
10
Pneumatic Valve Actuators - Air Operator Sizing Data
Air-to-Open
Series 10V Valves
Valve Maximum Pressure Flow Coefficient
Series Operator Duty System Pressure KSI (Mpa) psi (bar)* Cv**
1-6 8 10 12 14 15
(6.89-41.37) (110.31) (124.10) (82.74) (96.53) (103.42)
** Cv data is for 2-way straight valves. CAUTION: While testing has shown O-rings to provide satisfactory service life,
For angle pattern, add approximately 50% to the CV valve. both cyclic and shelf life may vary widely with differing service conditions,
properties of reactants, pressure and temperature cycling and age of the O-ring,
FREQUENT INSPECTIONS SHOULD BE MADE to detect any deterioration, and
O-rings replaced as required.
11
Air-to-Open
Series SW Valves
Valve Maximum Pressure Flow Coefficient
Series Operator Duty System Pressure KSI (Mpa) psi (bar)* Cv**
1-6 8 10 12 14 15
(6.89-41.37) (55.16) (68.95) (82.74) (96.53) (103.41)
Spring Pre-Compression: 0.19 0.19 0.25 0.31 0.36 0.38 15,000 0.65
SW4 Medium Duty in. (mm) (4.83) (4.83) (6.35) (7.87) (9.14) (9.14) (1034.20)
Spring Pre-Compression: 0.14 0.19 0.24 0.28 0.34 0.36 15,000 0.95
SW6 Heavy Duty in. (mm) (3.56) (4.83) (6.10) (7.11) (8.64) (9.14) (1034.20)
** Cv data is for 2-way straight valves. CAUTION: While testing has shown O-rings to provide satisfactory service life,
For angle pattern, add approximately 50% to the CV valve. both cyclic and shelf life may vary widely with differing service conditions,
properties of reactants, pressure and temperature cycling and age of the O-ring,
FREQUENT INSPECTIONS SHOULD BE MADE to detect any deterioration, and
O-rings replaced as required.
12
Air-to-Open - Series 10SM Valves
Valve Maximum Pressure Flow Coefficient
Series Operator Duty System Pressure KSI (Mpa) psi (bar)* Cv**
1-4 6 8 10 12 14 16 18 20
(6.89-27.58) (41.37) (55.15) (68.95) (82.74) (96.53) (110.31) (124.10) (137.89)
13
Air-to-Open - Series 20SM Valves
Valve Maximum Pressure Flow Coefficient
Operator Duty System Pressure KSI (Mpa) psi (bar)* Cv**
Series
1-4 6 8 10 12 14 16 18 20
(6.89-27.58) (41.37) (55.15) (68.95) (82.74) (96.53) (110.31) (124.10) (137.89)
14
Air-to-Open - Series 20SM Valves
Valve Maximum Pressure Flow Coefficient
Series Operator Duty System Pressure KSI (Mpa) psi (bar)* Cv**
1-4 6 8 10 12 14 16 18 20
(6.89-27.58) (41.37) (55.15) (68.95) (82.74) (96.53) (110.31) (124.10) (137.89)
Maximum rating is based on the valve rating. CAUTION: While testing has shown O-rings to provide satisfactory service life,
both cyclic and shelf life may vary widely with differing service conditions,
** Cv data is for 2-way straight valves. properties of reactants, pressure and temperature cycling and age of the
For angle pattern, add approximately 50% to the Cv valve. O-ring, FREQUENT INSPECTIONS SHOULD BE MADE to detect any deteriora-
tion, and O-rings replaced as required.
*** Cv varies because of spring compression limitations. The flow
*Maximum pressure rating is based on the lowest rating of any component.
coefficient range is given for the maximum stem travel (lowest system Actual working pressure may be determined by tubing pressure rating, if lower.
pressure) to minimum travel (highest system pressure).
All dimensions for reference only and subject to change.
For prompt service, Parker Autoclave Engineers stocks select products. Consult your local representative.
15
Air-to-Open - Series 30SC Valves
Valve Maximum Pressure Flow Coefficient
Series Operator Duty System Pressure KSI (Mpa) psi (bar)* Cv**
1-15 16 18 20 22 24 26 28 30
(6.89-103.42) (110.31) (124.10) (137.89) (151.68) (165.47) (179.26) (193.05) (206.84)
Spring Pre-Compression: 0.12 0.12 0.19 0.19 0.19 0.19 0.25 0.25 0.25 0.25 0.31 30,000 0.12
in. (mm) (3.15) (3.05) (4.83) (4.83) (4.83) (4.83) (6.35) (6.35) (6.35) (6.35) (7.87) (2068.39)
30VM4
Stem Travel 0.19 0.19 0.19 0.19 0.19 0.19 0.19 0.19 0.19 0.19 0.19
in (mm) (4.83) (4.83) (4.83) (4.83) (4.83) (4.83) (4.83) (4.83) (4.83) (4.83) (4.83)
Air Pressure: psi 25 25 30 30 30 30 35 35 35 35 40
Heavy Duty (bar) (1.72) (1.72) (2.07) (2.07) (2.07) (2.07) (2.41) (2.41) (2.41) (2.41) (2.76)
Spring Pre-Compression: 0.12 0.19 0.19 0.25 0.25 0.31 0.31 0.31 0.38 0.38 0.44 30,000 0.33
30VM6 in. (mm) (3.05) (4.83) (4.83) (6.35) (6.35) (7.87) (7.87) (7.87) (9.65) (9.65) (11.18) (2068.39) (30VM6)
&
30VM9 Stem Travel 0.19 0.19 0.19 0.19 0.19 0.19 0.19 0.19 0.19 0.19 0.19 0.33
in (mm) (4.13) (4.83) (4.83) (4.83) (4.83) (4.83) (4.83) (4.83) (4.83) (4.83) (4.83) (30VM9)
Air Pressure: psi 25 30 30 35 35 40 40 40 45 45 50
Heavy Duty (bar) (1.72) (2.07) (2.07) (2.41) (2.41) (2.76) (2.76) (2.76) (3.10) (3.10) (3.45)
Spring Pre-Compression: 0.12 0.18 0.25 0.31 0.38 0.43 0.5 40,000 0.28
in (mm) (3.05) (4.57) (6.35) (7.87) (9.65) (10.92) (12.70) (2757.86)
40VM9
Stem Travel 0.25 0.25 0.25 0.25 0.25 0.25 0.25
in (mm) (6.35) (6.35) (6.35) (6.35) (6.35) (6.35) (6.35)
Air Pressure: psi 30 35 40 45 50 50 55
Heavy Duty (bar) (2.07) (2.41) (2.76) (3.10) (3.45) (3.45) (3.79)
16
Air-to-Open - Series 60VM Valves
Valve Maximum Pressure Flow Coefficient
Series Operator Duty System Pressure KSI (Mpa) psi (bar)* Cv**
1-15 20 25 30 35 40 45 50 55 60
(6.89-103.42) (137.89) (172.37) (206.84) (241.31) (275.79) (310.26) (344.73) (379.21) (413.68)
Spring Pre-Compression: 0.12 0.19 0.19 0.19 0.25 0.25 0.31 0.31 0.31 0.38 60,000 0.08
60VM4 in. (mm) (3.05) (4.83) (4.83) (4.83) (6.35) (6.35) (7.87) (7.87) (7.87) (9.65) (4136.79) (60VM4)
&
60VM6 Stem Travel 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25
in (mm) (6.35) (6.35) (6.35) (6.35) (6.35) (6.35) (6.35) (6.35) (6.35) (6.35)
Air Pressure: psi 30 35 35 35 40 40 45 45 45 50 0.09
Heavy Duty (bar) (2.07) (2.41) (2.41) (2.41) (2.76) (2.76) (3.10) (3.10) (3.10) (3.45) (60VM6)
Spring Pre-Compression: 0.12 0.19 0.19 0.25 0.25 0.31 0.38 0.38 0.44 0.50 60,000 0.14
in. (mm) (3.05) (4.83) (4.83) (6.35) (6.35) (7.87) (9.65) (9.65) (11.18) (12.70) (4136.79)
60VM9
Stem Travel 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.19 0.12
in (mm) (6.35) (6.35) (6.35) (6.35) (6.35) (6.35) (6.35) (6.35) (4.83) (3.05)
Air Pressure: psi 30 35 35 40 40 45 50 50 50 50
Heavy Duty (bar) (2.07) (2.41) (2.41) (2.76) (2.76) (3.10) (3.45) (3.45) (3.45) (3.45)
Stem Travel 0.12 0.12 0.12 0.12 0.12 0.12 0.12 0.06
in (mm) (3.05) (3.05) (3.05) (3.05) (3.05) (3.05) (3.05) (1.52)
** Cv data is for 2-way straight valves. CAUTION: While testing has shown O-rings to provide satisfactory service life,
For angle pattern, add approximately 50% to the Cv valve. both cyclic and shelf life may vary widely with differing service conditions,
properties of reactants, pressure and temperature cycling and age of the O-ring,
*** Cv varies because of spring compression limitations. The flow FREQUENT INSPECTIONS SHOULD BE MADE to detect any deterioration, and
coefficient range is given for the maximum stem travel (lowest system O-rings replaced as required.
pressure) to minimum travel (highest system pressure).
*Maximum pressure rating is based on the lowest rating of any component.
Actual working pressure may be determined by tubing pressure rating, if lower.
All dimensions for reference only and subject to change.
For prompt service, Parker Autoclave Engineers stocks select products. Consult your local representative.
17
WARNING
FAILURE, IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS AND/OR SYSTEMS DESCRIBED HEREIN OR RELATED ITEMS CAN CAUSE DEATH, PERSONAL INJURY AND PROPERTY DAMAGE.
This document and other information from Parker Hannifin Corporation, its subsidiaries and authorized distributors provide product and/or system options for further investigation by users having technical
expertise. It is important that you analyze all aspects of your application and review the information concerning the product or system in the current product catalog. Due to the variety of operating conditions
and applications for these products or systems, the user, through its own analysis and testing, is solely responsible for making the final selection of the products and systems and assuring that all performance,
safety and warning requirements of the application are met. The products described herein, including without limitation, product features, specifications, designs, availability and pricing, are subject to change by
Parker Hannifin Corporation and its subsidiaries at any time without notice.
Offer of Sale
The items described in this document are available for sale by Parker Hannifin Corporation, its subsidiaries or its authorized distributors. Any sale contract entered by Parker will be governed by the provisions
stated in Parker's standard terms and conditions of sale (copy available upon request).
2013 Parker Hannifin Corporation | Autoclave Engineers is a registered trademark of the Parker Hannifin Corporation 02-0121SE January2013
Instrumentation Products Division Parker Hannifin Manufacturing Ltd. Caution! Parker Autoclave Engineers Valves, Fittings and Tools are
not designed to work with common commercial instrument tubing
Autoclave Engineers Operation Instrumentation Products Division, Europe
and will only work with tubing built to Parker Autoclave Engineers
8325 Hessinger Drive Industrial Estate Whitemill AES Specifications. Failure to do so will void warranty.
Erie, Pennsylvania 16509-4679 USA Wexford, Republic of Ireland
PH: 814-860-5700 FAX: 814-860-5811 PH: 353 53 914 1566
www.autoclave.com FAX: 353 53 914 1582 ISO-9001 Certified
Electric Flow
Control Valve
Pressures to 60,000 psi (4137 bar)
www.autoclave.com
Flow Control Valvs - Electric
Pressures to 60,000 psi (4137 bar)
Tube Pressure
Outside Rating
Diameter Orifice psi (bar)
Size Connection Size Rated @ Room
Inches Type Inches (mm) Cv Temperature**
.
Note:
repeatability. 0.125
(3.18)
Power Requirement: 24VDC/50 Watts Min. 0.100
Control Input: 4-20 mA or 0-10 VDC (2.54)
Operating Temperature: -22F (-30C) to 185F (85C) 0.075
(1.90)
2 foot lead cable
0.050
Anodized Aluminum Housing, IP65 (NEMA 4X) Weatherproof (1.27)
0.025
(.64)
0
0.001 0.002 0.003 0.004
Cv
Ordering Information
Note: For micrometering valve details see
Model Control No. Controller Fig. needle valve section.
Input Rotations RPMs
10VRMM2812-C4 4 - 20 mA 6 10 1
10VRMM2812-C10 0 - 10 VDC 6 10 1
30VRMM4812-C4 4 - 20 mA 6 10 2
30VRMM4812-C10 0 - 10 VDC 6 10 2
60VRMM4812-C4 4 - 20 mA 6 10 2
60VRMM4812-C10 0 - 10 VDC 6 10 2
60VRMM6812-C4 4 - 20 mA 6 10 2
60VRMM6812-C10 0 - 10 VDC 6 10 2
2 All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold.
Valve Options Valve Maintenance
Extreme Temperatures Repair Kits: add R to the front of valve catalog
Standard Parker Autoclave Engineers valves with PTFE packing may be number for proper repair kit.
operated to 450F (232C). Optional packing or trim material available (Example: R60VRMM4882-C)
by adding the following suffixes to catalog order number.= Valve Bodies: Valve bodies are available. Order using the eight (8)
TG - standard valve with PTFE glass packing to 600F (316C). digit part number found on the valve drawing or
B - standard valve with cryogenic trim material and PTFE packing to -100F (-73C). contact your Sales Representative for information.
=
Parker Autoclave Engineers does not recommend compression sleeve connec-
Consult your Parker Autoclave Engineers representative for pricing on repair
tions below 0F (-17.8C) or above 650F (343C). For additional valve options,
kits and valve bodies. Refer to the Tools, Installation, Operation and Mainte-
contact your Sales Representative. nance section for proper maintenance procedures.
See Needle Valve options for stem and seat coatings for erosive service.
Metering valve not to be used as a shutoff valve.
10VRMM2812-C4 1/8 0.062 1.50 0.88 0.31 0.94 1.56 4.50 2.50 4.75 3.50 0.75 See
K Electronic Valve K
10VRMM2812-C10 (3.17) (1.57) (38.10) (22.35)Actuator
(7.87) (23.87) (39.62) (114.30) (63.50) (120.65) (88.90) (19.05) Figure 1
K Electronic Valve K
30VRMM4812-C4
Electronic Valve 1/4 0.062 2.00 1.00 *0.50 1.12 2.00 3.50 3.50 4.75 3.50 1.00 Actuator
Actuator
30VRMM4812-C10 (6.35) (1.57) (50.80) (25.40) (12.70) (28.44) (50.80) (88.90) (88.90) (120.65) (88.90) (25.40)
60VRMM4812-C4 1/4 0.062 J 2.00 1.00 0.50 1.31 2.63 Electronic
3.50 Valve 3.50 8.30 4.10 1.00 See
60VRMM4812-C10 (6.35) (1.57) (50.80) (25.40) (12.70) (33.27) (66.80) Actuator
(88.90) (88.90) (210.80) (104.14) (25.40) Figure 2
60VRMM6812-C4 3/8 0.062 2.00 1.00 0.53 1.31 2.63 3.50 J 3.50 8.30 4.10 J 1.00
60VRMM6812-C10 (9.53) (1.57) (50.80) (25.40) (13.46) (33.27) (66.80) (88.90) (88.90) (210.80) (104.14) (25.40)
View A J J
*Distance gland extends
Coupling
View A J
F
Mounting Bracket Coupling
Coupling 30VRMM/60VRMM
K F Electronic Valve KF
Mounting Rods Actuator
Mounting Bracket Coupling
C D
E 10VRMM
Support Plate
60VRMM F
Mounting Rods
Electronic Valve 0.250
Actuator K (6.35) D Electronic Valve K
C Actuator D
E Support Plate
E
J
B C 0.250
A (6.35) D
Electronic Valve 30VRMM E
Actuator J
B C
A
B J
A J
View A
Coupling J B
A
F J
View A
Mounting Bracket Coupling
0.50
Coupling
(12.70) 0.50
(12.70) F
Mounting Rods
+ + 3.50F
(88.90) 0.50
0.75 D
(19.05)
Mounting Bracket
C E Support PlateCoupling
(12.70) 0.50
(12.70)
+ +
+ + 0.250 3.50
0.20 TYP
F (88.90)
2.90 Mounting Rods
0.75 (6.35) D
(5.16) (73.66) (19.05)
1.50 + +E
(38.1) D
C E Support Plate
B 0.20 TYP C
2.50 2.90
(63.50) A (5.16) (73.66)
0.34 TYP 1.50
(8.74) 0.250
(38.1) (6.35) D
2.50
E
(63.50) 0.34 TYP
B B C (8.74)
A A
All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold. 3
0.50
(12.70) 0.50
(12.70)
3.50
WARNING
FAILURE, IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS AND/OR SYSTEMS DESCRIBED HEREIN OR RELATED ITEMS CAN CAUSE DEATH, PERSONAL INJURY AND PROPERTY DAMAGE.
This document and other information from Parker Hannifin Corporation, its subsidiaries and authorized distributors provide product and/or system options for further investigation by users having technical
expertise. It is important that you analyze all aspects of your application and review the information concerning the product or system in the current product catalog. Due to the variety of operating conditions
and applications for these products or systems, the user, through its own analysis and testing, is solely responsible for making the final selection of the products and systems and assuring that all performance,
safety and warning requirements of the application are met. The products described herein, including without limitation, product features, specifications, designs, availability and pricing, are subject to change by
Parker Hannifin Corporation and its subsidiaries at any time without notice.
Offer of Sale
The items described in this document are available for sale by Parker Hannifin Corporation, its subsidiaries or its authorized distributors. Any sale contract entered by Parker will be governed by the provisions
stated in Parker's standard terms and conditions of sale (copy available upon request).
2013 Parker Hannifin Corporation | Autoclave Engineers is a registered trademark of the Parker Hannifin Corporation 02-9228BE January2013
Instrumentation Products Division Parker Hannifin Manufacturing Ltd. Caution! Parker Autoclave Engineers Valves, Fittings and Tools are
Autoclave Engineers Operation Instrumentation Products Division, Europe not designed to work with common commercial instrument tubing
and will only work with tubing built to Parker Autoclave Engineers
8325 Hessinger Drive Industrial Estate Whitemill
AES Specifications. Failure to do so will void warranty.
Erie, Pennsylvania 16509-4679 USA Wexford, Republic of Ireland
PH: 814-860-5700 FAX: 814-860-5811 PH: 353 53 914 1566
www.autoclave.com FAX: 353 53 914 1582 ISO-9001 Certified
Fittings and Tubing
Low Pressure
Pressures to 15,000 psi (1034 bar)
The Low Pressure Series uses Parker Autoclave Engineers' SpeedBite connection. This single-
ferrule compression sleeve connection delivers fast, easy make-up and reliable bubble-tight
performance, in liquid or gas service.
www.autoclave.com
Fittings and Tubing - Low Pressure Fittings
Pressures to 15,000 psi (1034 bar)
Parker Autoclave Engineers Low Pressure Fittings
are designed for use with low pressure valves and
tubing. These fittings feature improved SpeedBite
compression connections with larger orifices for
excellent flow capabilities. Parker Autoclave Engi-
neers fittings and components are manufactured of
cold-worked type 316 stainless steel. Optional
materials are available upon request.
Connection Components
All valves and fittings are supplied complete with appropriate glands and compression sleeves. To order these components sepa-
rately, use order numbers listed. When using plug, sleeve is not required.
Gland Sleeve Plug
SMN ( ) SSL ( ) SP ( )
Add tube size ( ) When ordering glands separately for 10V Series 1/4 and 3/8 valves, substitute
1/8 - 20 10N for SMN.
1/4 - 40
3/8 - 60 1/16 tubing system components are available in the mini-fitting series. 1/16 tubing
1/2 - 80 components can be used in 10V Series valves and fittings if required. Consult factory
for information on 1/16 tubing assembly in 1/8 tubing components.
Example: 1/4 Gland - SMN 40
Note: Special material glands may be supplied with four To ensure proper fit use Parker Autoclave Engineers tubing. For mounting hole op-
flats in place of standard hex. tion add suffix PM to catalog number. Consult factory for mounting hole dimensions.
Elbow
SL2200 W125 1/8 15,000 0.094 1.00 1.50 0.31 0.38 0.75 0.75 0.62
(3.18) (1034.19) (2.39) (25.40) (38.10) (7.87) (9.53) (19.05) (19.05) (15.75)
SL4400 SW250 1/4 15,000 0.188 1.38 2.00 0.44 0.63 1.00 1.00 0.75
(6.35) (1034.19) (4.78) (35.05) (50.80) (11.18) (15.88) (25.40) (25.40) (19.05) See
SL6600 SW375 3/8 15,000 0.250 1.38 2.00 0.53 0.75 1.00 1.00 0.75 Figure 1
(9.53) (1034.19) (6.35) (35.05) (50.80) (13.46) (19.05) (25.40) (25.40) (19.05)
SL8800 SW500 1/2 10,000 0.375 1.75 2.50 0.53 0.93 1.25 1.25 1.00
(12.70) (689.46) (9.53) (44.45) (63.50) (13.46) (23.62) (31.75) (31.75) (25.40)
E
A
Elbow
2 All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold.
Outside Pressure Dimensions - inches (mm)
Catalog Connection Minimum Block Fitting
Diameter Rating Opening A B C D E F G Thickness
Number Type Pattern
Tube psi (bar)* Typical Thickness
Tee
ST2220 W125 1/8 15,000 0.094 1.00 1.50 0.31 0.38 0.75 0.75 0.62
(3.18) (1034.19) (2.39) (25.40) (38.10) (7.87) (9.53) (19.05) (19.05) (15.75)
ST4440 SW250 1/4 15,000 0.188 1.38 2.00 0.44 0.63 1.00 1.00 0.75
(6.35) (1034.19) (4.78) (35.05) (50.80) (11.18) (15.88) (25.40) (25.40) (19.05)
See
ST6660 SW375 3/8 15,000 0.250 1.38 2.00 0.53 0.75 1.00 1.00 0.75 Figure 2
(9.53) (1034.19) (6.35) (35.05) (50.80) (13.46) (19.05) (25.40) (25.40) (19.05)
ST8880 SW500 1/2 10,000 0.375 1.75 2.50 0.53 0.93 1.25 1.25 1.00
(12.70) (689.46) (9.53) (44.45) (63.50) (13.46) (23.62) (31.75) (31.75) (25.40)
Cross
SX2222 W125 1/8 15,000 0.094 1.50 1.50 0.31 0.38 0.75 0.75 0.62
(3.18) (1034.19) (2.39) (38.10) (38.10) (7.87) (9.53) (19.05) (19.05) (15.75)
SX4444 SW250 1/4 15,000 0.188 2.00 2.00 0.44 0.63 1.00 1.00 0.75
(6.35) (1034.19) (4.78) (50.80) (50.80) (11.18) (15.88) (25.40) (25.40) (19.05) See
SX6666 SW375 3/8 15,000 0.250 2.00 2.00 0.53 0.75 1.00 1.00 0.75 Figure 3
(9.53) (1034.19) (6.35) (50.80) (50.80) (13.46) (19.05) (25.40) (25.40) (19.05)
SX8888 SW500 1/2 10,000 0.375 2.50 2.50 0.53 0.93 1.25 1.25 1.00
(12.70) (689.46) (9.53) (63.50) (63.50) (13.46) (23.62) (31.75) (31.75) (25.40)
Straight Coupling
15F2211 W125 1/8 15,000 0.094 0.50 1.25 0.31 0.38
(3.18) (1034.19) (2.39) (12.70) (31.75) (7.87) (9.53)
6F4422 SW250 1/4 15,000 0.188 0.62 1.62 0.44 0.63
(6.35) (1034.19) (4.78) (15.75) (41.15) (11.18) (15.88) See
6F6622 SW375 3/8 15,000 0.250 0.75 1.75 0.53 0.75 Figure 4
(9.53) (1034.19) (6.35) (19.05) (44.45) (13.46) (19.05)
4F8822 SW500 1/2 10,000 0.375 1.00 2.00 0.53 0.93
(12.70) (689.46) (9.53) (25.40) (50.80) (13.46) (23.62)
Bulkhead Coupling
15BF2211 W125 1/8 15,000 0.094 0.690 1.75 0.31 0.38 0.38 0.75 0.38
(3.18) (1034.19) (2.39) (17.53) (44.45) (7.87) (9.53) (9.53) (19.05) (9.53)
6BF4422 SW250 1/4 15,000 0.188 0.940 1.88 0.44 0.63 0.50 1.00 0.38
(6.35) (1034.19) (4.78) (23.88) (47.75) (11.18) (15.88) (12.70) (25.40) (9.53) See
6BF6622 SW375 3/8 15,000 0.250 0.940 1.88 0.53 0.75 0.50 1.00 0.38 Figure 5
(9.53) (1034.19) (6.35) (23.88) (47.75) (13.46) (19.05) (12.70) (25.40) (9.53)
4BF8822 SW500 1/2 10,000 0.375 1.120 2.38 0.53 0.93 0.78 1.38 0.38
(12.70) (689.46) (9.53) (28.45) (60.45) (13.46) (23.62) (19.81) (35.05) (9.53)
Figure 2 Figure 3 *Maximum pressure rating is based on the lowest rating of any component.
Actual working pressure may be determined by tubing pressure rating, if
F lower.
D HEX
F C All dimensions for reference only and subject to change.
For prompt service, Parker Autoclave Engineers stocks select products.
C Consult your local representative.
E
D
E HEX
A A
B
B
Tee Cross
Figure 4 Figure 5
A HEX G MAX
D F D
A
HEX HEX HEX
C E
B
B C
All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold. 3
Fittings and Tubing - Mini Series Fittings
Pressure to 15,000 psi (1034 bar)
All Parker Autoclave Engineers valves and fittings are supplied complete with appropriate glands and compression
sleeves. To order these components separately, use order numbers listed. When using plug, sleeve is not required.
Gland Add gland size ( ) Example: SMN - 10 Note: Gland sizes differ as folllows:
SMN ( ) 1/16 - 10 Standard is 3/8 hex
1/16 - 10-10mm 10 mm is 10 millimeter hex
1/8 - 20
1/8 - 20-10mm
Sleeve
SSL ( ) Add tube size for sleeve and plug ( ) Example: 1/8 Sleeve SSL20
1/16 - 10
1/8 - 20
Plug
SP ( )
Note: Special material glands may be supplied with four flats in place of standard hex.
MLE1100 W062 1/16 15,000 0.055 1.00 1.00 0.31 0.38 0.69 0.69 0.56
(1.59) (1034.20) (1.40) (25.40) (25.40) (7.87) (9.53) (17.45) (17.45) (14.27)
MLE2200 W125 1/8 15,000 0.093 1.00 1.00 0.31 0.38 0.69 0.69 0.56
(3.18) (1034.20) (2.36) (25.40) (25.40) (7.87) (9.53) (17.45) (17.45) (14.27)
See
10 millimeter hex glands (D Dimension)
Figure 1
ML1100 W062 1/16 15,000 0.055 1.00 1.00 0.31 0.39 0.69 0.69 0.56
(1.59) (1034.20) (1.40) (25.40) (25.40) (7.87) (10.00) (17.45) (17.45) (14.27)
ML2200 W125 1/8 15,000 0.093 1.00 1.00 0.31 0.39 0.69 0.69 0.56
(3.18) (1034.20) (2.36) (25.40) (25.40) (7.87) (10.00) (17.45) (17.45) (14.27)
E
A
Elbow
4 All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold.
Outside Pressure Dimensions - inches (mm)
Catalog Connection Minimum Block Fitting
Diameter Rating Opening A B C D E F Thickness
Number Type Pattern
Tube psi (bar)* Typical
MTE1110 W062 1/16 15,000 0.055 1.00 1.38 0.31 0.38 0.69 0.69 0.56
(1.59) (1034.20) (1.40) (25.40) (34.93) (7.87) (9.53) (17.45) (17.45) (14.27)
MTE2220 W125 1/8 15,000 0.093 1.00 1.38 0.31 0.38 0.69 0.69 0.56
(3.18) (1034.20) (2.36) (25.40) (34.93) (7.87) (9.53) (17.45) (17.45) (14.27)
See
10 millimeter hex glands (D Dimension) Figure 2
MT1110 W062 1/16 15,000 0.055 1.00 1.38 0.31 0.39 0.69 0.69 0.56
(1.59) (1034.20) (1.40) (25.40) (34.93) (7.87) (10.00) (17.45) (17.45) (14.27)
MT2220 W125 1/8 15,000 0.093 1.00 1.38 0.31 0.39 0.69 0.69 0.56
(3.18) (1034.20) (2.36) (25.40) (34.93) (7.87) (10.00) (17.45) (17.45) (14.27)
MXE1111 W062 1/16 15,000 0.055 1.38 1.38 0.31 0.38 0.69 0.69 0.56
(1.59) (1034.20) (1.40) (34.93) (34.93) (7.87) (9.53) (17.45) (17.45) (14.27)
MXE2222 W125 1/8 15,000 0.093 1.38 1.38 0.31 0.38 0.69 0.69 0.56
(3.18) (1034.20) (2.36) (34.93) (34.93) (7.87) (9.53) (17.45) (17.45) (14.27)
See
10 millimeter hex glands (D Dimension)
Figure 3
MX1111 W062 1/16 15,000 0.055 1.38 1.38 0.31 0.39 0.69 0.69 0.56
(1.59) (1034.20) (1.40) (34.93) (34.93) (7.87) (10.00) (17.45) (17.45) (14.27)
MX2222 W125 1/8 15,000 0.093 1.38 1.38 0.31 0.39 0.69 0.69 0.56
(3.18) (1034.20) (2.36) (34.93) (34.93) (7.87) (10.00) (17.45) (17.45) (14.27)
D HEX F
F C A HEX
C
E
D D
E HEX HEX
A A C
B
B
B
All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold. 5
Fittings and Tubing - Low Pressure Tubing
Pressures to 15,000 psi (1034 bar)
Catalog Tube Fits Tube Size Inches (mm) Flow Working Pressure psi (bar)*
Number Materials Connection Outside Inside Wall Area 0 - 100F 200F 400F 600F 650F
Type Diameter Diameter Thickness in.2 (mm2) -17.8 to 37.8C 93C 204C 316C 343C
MS15-070 316SS W062 1/16 0.026 0.018 0.0005 15,000 15,000 14,400 13,600 12,600
(1.59) (0.66) (0.46) (0.32) (1034.20) (1034.20) (992.83) (937.67) (868.73)
MS15-200 316SS 0.052 0.036 0.002 15,000 15,000 14,400 13,600 12,600
1/8 (1.32) (0.91) (1.29) (1034.20) (1034.20) (992.83) (937.67) (868.73)
W125
MS15-166= 304SS (3.18) 0.069 0.028 0.004 9,950 9,400 8,550 8,450 8,000
(1.75) (0.71) (2.58) (686.02) (648.10) (589.49) (582.60) (551.57)
MS15-203 316SS 0.084 0.083 0.029 15,000 15,000 14,400 13,600 12,600
(2.13) (2.11) (18.71) (1034.16) (1034.16) (992.83) (937.67) (868.73)
MS15-055 316SS 0.125 0.062 0.012 11,650 11,650 11,250 10,600 9,850
(3.18) (1.57) (7.74) (803.23) (761.86) (775.65) (730.83) (679.12)
W250
MS15-161= 304SS 1/4 0.180 0.035 0.026 5,450 5,150 4,700 4,600 4,400
or
(6.35) (4.57) (0.89) (16.77) (375.76) (355.07) (324.05) (317.15) (303.36)
SW250
MS15-069 316SS 0.180 0.035 0.026 5,450 5,450 5,250 4,950 4,600
(4.57) (0.89) (16.77) (375.76) (375.76) (361.97) (341.29) (317.15)
MS15-158= 304SS 0.194 0.028 0.029 4,600 4,350 3,950 3,900 3,700
(4.93) (0.71) (18.71) (317.15) (299.92) (272.34) (272.34) (255.10)
MS15-204 316SS 0.139 0.118 0.015 15,000 15,000 14,400 13,600 12,600
(3.53) (3.00) (9.79) (1034.16) (1034.16) (992.83) (937.67) (868.73)
MS15-184 304SS W375 0.195 0.090 0.030 10,000 9,400 8,600 8,500 8,450
3/8 (4.95) (2.29) (19.35) (689.46) (648.10) (592.94) (586.05) (582.60)
or
MS15-084 316SS (9.53) 0.195 0.090 0.030 10,000 10,000 9,650 9,000 8,400
SW375
(4.95) (2.29) (19.35) (689.46) (689.46) (665.33) (620.52) (579.15)
MS15-155= 304SS 0.250 0.062 0.049 7,500 7,100 6,450 6,350 6,050
(6.35) (1.57) (31.61) (517.10) (489.52) (444.70) (437.81) (417.13)
All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold.
6
Catalog Tube Fits Tube Size Inches (mm) Flow Working Pressure psi (bar)*
Number Materials Connection Outside Inside Wall Area 0 - 100F 200F 400F 600F 650F
Type Diameter Diameter Thickness in.2 (mm2) -17.8 to - 37.8C 93C 204C 316C 343C
MS15-062 316SS W375 3/8 0.250 0.062 0.049 7,500 7,500 7,200 6,800 6,300
or (9.53) (6.35) (1.57) (31.61) (517.10) (517.10) (496.41) (468.84) (434.36)
MS15-162= 304SS SW375 0.305 0.035 0.073 3,800 3,550 3,250 3,200 3,050
(7.75) (0.89) (47.10) (262.00) (244.76) (224.08) (220.63) (210.29)
MS15-205 316SS 0.270 0.118 0.055 10,000 10,000 9,650 9,000 8,400
(6.86) (3.00) (35.48) (689.46) (689.46) (665.33) (620.52) (579.15)
MS15-208= 304SS W500 1/2 0.270 0.118 0.055 10,000 9,400 8,600 8,500 8,450
or (12.70) (6.86) (3.00) (35.48) (689.46) (648.10) (592.94) (586.05) (582.60
MS15-065 316SS SW500 0.375 0.062 0.110 5,500 5,500 5,250 4,950 4,600
(9.53) (1.57) (70.97) (379.21) (379.21) (361.97) (341.29) (317.15)
MS15-165= 304SS 0.402 0.048 0.127 4,000 3,750 3,400 3,400 3,200
(10.21) (1.22) (81.94) (275.79) (258.55) (234.42) (234.42) (220.63)
*Maximum pressure rating is based on the lowest rating of any component. All dimensions for reference only and subject to change.
Actual working pressure may be determined by tubing pressure rating, if lower. For prompt service, Parker Autoclave Engineers stocks select products.
Consult your local representative.
=
Items are being discontinued. Contact the factory for available stock
Ball Check Valves Prevent reverse flow where leak-tight shut-off is not manda-
tory. When differential drops below cracking pressure, valve
closes. With all-metal components, valve can be used up to
650F (343C). See Technical Information section for connec-
tion temperature limitations. (Not for use as a relief valve.)
Ball and poppet are an integral design to assure positive,
in-line seating without chatter. Poppet is designed essen-
tially for axial flow with minimum pressure drop.
FLOW
Materials: 316 Stainless Steel: body, cover, cover gland, ball
poppet. 300 Series Stainless Steel: spring
Minimum operating temperature for standard ball check
valves 0F (-17.8C). CAUTION: While testing has shown O-Rings to provide satisfactory service life, both cyclic and shelf
For low temperature option to -100F (-73C) add suffix life may vary widely with differing service conditions, properties of reactants, pressure and temperature
cycling and age of the O-ring. FREQUENT INSPECTIONS SHOULD BE MADE to detect any deterioration,
LT (Low temperature spring). and O-rings replaced as required.
All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold. 7
Ball Type Excess Flow Valves
gland up).
Resetting Valve: Equalize the pressure across the poppet.
The poppet will drop and reset automatically.
CAUTION: While testing has shown O-Rings to provide satisfactory service life, both cyclic and shelf
life may vary widely with differing service conditions, properties of reactants, pressure and temperature
cycling and age of the O-ring. FREQUENT INSPECTIONS SHOULD BE MADE to detect any deterioration,
and O-rings replaced as required.
8 All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold.
Fittings and Tubing - Low Pressure Check Valves
Note:
All check valves are furnished complete with connection components unless otherwise specified.
The 1/16 Tubing System is a complete system for use with all 1/8 components for pressure to 15,000 psi (1034 bar). Consult factory.
= - Check Flow** - water, GPM
== - Check Flow** - CFM, nitrogen @ 500 psi (34.47 bar), RT
** - For flow using alternate fluids, consult Parker Autoclave Engineers. Figure 1
HEX D HEX
C C
All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold. 9
Fittings and Tubing - Low Pressure Line Filters
Pressures to 15,000 psi (1034 bar)
NOTE 1: All filters furnished complete with connection components unless otherwise specified. All
dimensions for reference only and subject to change. For optional materials, see Needle Valve Options
section
NOTE 2: Parker Autoclave Engineers disc and cup type filters are designed to filter small amounts of
process particles. It is recommended that all fluids are thoroughly cleaned prior to entering the higher
pressure system.
NOTE 3: Special material filters may be supplied with four flats in place of standard hex.
NOTE 4: Pressure differential not to exceed 1,000 psi (69 bar) in a flowing condition.
NOTE 5: Larger micron size filter element is installed on the upstream (inlet) side.
10 All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold.
Fittings and Tubing - Low Pressure Line Filters
** Larger micron size filter element is installed on upstream (inlet) side. All filters furnished complete *Maximum pressure rating is based on the lowest rating of any component.
with connection components unless otherwise specified. Actual working pressure may be determined by tubing pressure rating, if lower.
All dimensions for reference only and subject to change.
Other micron sizes available on special order. Change last digits of the catalog number accordingly. For
optional materials, see Needle Valve Options section. For prompt service, Parker Autoclave Engineers stocks select products. Consult your local
representative.
The 1/16 Tubing System is a complete system for use with all 1/8 components for pressure to 15,000
psi (1034 bar). Consult factory.
A A
D
D
B HEX C B C HEX
C C
HEX HEX
All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold. 11
WARNING
FAILURE, IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS AND/OR SYSTEMS DESCRIBED HEREIN OR RELATED ITEMS CAN CAUSE DEATH, PERSONAL INJURY AND PROPERTY DAMAGE.
This document and other information from Parker Hannifin Corporation, its subsidiaries and authorized distributors provide product and/or system options for further investigation by users having technical
expertise. It is important that you analyze all aspects of your application and review the information concerning the product or system in the current product catalog. Due to the variety of operating conditions
and applications for these products or systems, the user, through its own analysis and testing, is solely responsible for making the final selection of the products and systems and assuring that all performance,
safety and warning requirements of the application are met. The products described herein, including without limitation, product features, specifications, designs, availability and pricing, are subject to change by
Parker Hannifin Corporation and its subsidiaries at any time without notice.
Offer of Sale
The items described in this document are available for sale by Parker Hannifin Corporation, its subsidiaries or its authorized distributors. Any sale contract entered by Parker will be governed by the provisions
stated in Parker's standard terms and conditions of sale (copy available upon request).
2013 Parker Hannifin Corporation | Autoclave Engineers is a registered trademark of the Parker Hannifin Corporation 02-0123SE January2013
The medium pressure series uses Parker Autoclave Engineers medium pressure connection.
This coned-and-threaded connection features orifice sizes to match the high flow characteristics
of this series.
www.autoclave.com
Medium Pressure Fittings
Pressures to 20,000 psi (1379 bar)
Connection Components
All Parker Autoclave valves and fittings are supplied complete with appropriate glands and collars. To order these components
separately, use order numbers listed. When using plug, collar is not required.
Add tube size ( ) Example: To ensure proper fit use Parker Autoclave Engineers tubing.
1/4 - 40 1/4 Gland - CGLX 40
3/8 - 60 Note: Special material glands may be supplied with four flats
9/16 - 90 in place of standard hex.
3/4 - 120
1 - 160
1-1/2" - 240
Elbow
CLX4400 SF250CX 1/4 20,000 0.125 1.12 1.50 0.38 0.50 0.75 0.75 0.62
(6.35) (1378.93) (3.18) (28.45) (38.10) (9.53) (12.70) (19.05) (19.05) (15.75)
CLX6600 SF375CX 3/8 20,000 0.219 1.38 2.00 0.44 0.62 1.00 1.00 0.75
(9.53) (1378.93) (5.56) (35.05) (50.80) (11.10) (15.75) (25.40) (25.40) (19.05)
CLX9900 SF562CX 9/16 20,000 0.359 1.75 2.50 0.53 0.94 1.25 1.25 1.00
(14.29) (1378.93) (9.12) (44.45) (63.50) (13.46) (23.88) (31.75) (31.75) (25.40) See
CLX12 SF750CX 3/4 20,000 0.516 2.25 3.00 0.62 1.19 1.50 1.50 1.38 Figure 1
(19.05) (1378.93) (13.11) (57.15) (76.20) (15.75) (30.23) (38.10) (38.10) (34.93)
CLX16 SF1000CX 1 20,000 0.688 3.00 4.12 0.72 1.38 2.06 2.06 1.75
(25.40) (1378.93) (17.48) (76.20) (104.65) (18.29) (35.05) (52.32) (52.32) (44.45)
CLX24 SF1500CX 1-1/2 15,000 0.94 4.00 5.75 1.12 1.88 2.88 2.88 2.25
(38.10) (1034.20) (23.80) (101.60) (146.05) (28.45) (47.63) (73.03) (73.03) (57.15)
*Maximum pressure rating is based on the lowest rating Figure 1 For mounting hole option add suffix PM to catalog number.
of any component. Consult factory for mounting hole dimensions.
Actual working pressure may be determined by tubing
pressure rating, if lower. D HEX
All dimensions for reference only and subject to change.
F
For prompt service, Parker Autoclave Engineers stocks select products.
Consult your local representative.
C
E
A
B
Elbow
2 All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold.
Outside Pressure Dimensions - inches (mm)
Catalog Connection Minimum Block Fitting
Diameter Rating Opening A B C D E F G Thickness
Number Type Pattern
Tube psi (bar)* Typical Thickness
Tee
CTX4440 SF250CX 1/4 20,000 0.125 1.12 1.50 0.38 0.50 0.75 0.75 0.62
(6.35) (1378.93) (3.18) (28.45) (38.10) (9.53) (12.70) (19.05) (19.05) (15.75)
CTX6660 SF375CX 3/8 20,000 0.219 1.38 2.00 0.44 0.62 1.00 1.00 0.75
(9.53) (1378.93) (5.56) (35.05) (50.80) (11.10) (15.75) (25.40) (25.40) (19.05)
CTX9990 SF562CX 9/16 20,000 0.359 1.75 2.50 0.53 0.94 1.25 1.25 1.00
(14.29) (1378.93) (9.12) (44.45) (63.50) (13.46) (23.88) (31.75) (31.75) (25.40) See
CTX12 SF750CX 3/4 20,000 0.516 2.25 3.00 0.62 1.19 1.50 1.50 1.38 Figure 2
(19.05) (1378.93) (13.11) (57.15) (76.20) (15.75) (30.23) (38.10) (38.10) (34.93)
CTX16 SF1000CX 1 20,000 0.688 3.00 4.12 0.72 1.38 2.06 2.06 1.75
(25.40) (1378.93) (17.48) (76.20) (104.65) (18.29) (35.05) (52.32) (52.32) (44.45)
CTX24 SF1500CX 1-1/2 15,000 0.94 4.00 5.75 1.12 1.88 2.88 2.88 2.25
(38.10) (1034.20) (23.80) (101.60) (146.05) (28.45) (47.63) (73.03) (73.03) (57.15)
Cross
CXX4444 SF250CX 1/4 20,000 0.125 1.50 1.50 0.38 0.50 0.75 0.75 0.62
(6.35) (1378.93) (3.18) (38.10) (38.10) (9.53) (12.70) (19.05) (19.05) (15.75)
CXX6666 SF375CX 3/8 20,000 0.219 2.00 2.00 0.44 0.62 1.00 1.00 0.75
(9.53) (1378.93) (5.56) (50.80) (50.80) (11.10) (15.75) (25.40) (25.40) (19.05)
CXX9999 SF562CX 9/16 20,000 0.359 2.50 2.50 0.53 0.94 1.25 1.25 1.00
(14.29) (1378.93) (9.12) (63.50) (63.50) (13.46) (23.88) (31.75) (31.75) (25.40) See
CXX12 SF750CX 3/4 20,000 0.516 3.00 3.00 0.62 1.19 1.50 1.50 1.38 Figure 3
(19.05) (1378.93) (13.11) (76.20) (76.20) (15.75) (30.23) (38.10) (38.10) (34.93)
CXX16 SF1000CX 1 20,000 0.688 4.12 4.12 0.72 1.38 2.06 2.06 1.75
(25.40) (1378.93) (17.48) (104.65) (104.65) (18.29) (35.05) (52.32) (52.32) (44.45)
CXX24 SF1500CX 1-1/2 15,000 0.94 5.75 5.75 1.12 1.88 2.88 2.88 2.25
(38.10) (1034.20) (23.80) (146.05) (146.05) (28.45) (47.63) (73.03) (73.03) (57.15)
*Maximum pressure rating is based on the lowest rating of any component. For mounting hole option add suffix PM to catalog number.
Actual working pressure may be determined by tubing pressure rating, Consult factory for mounting hole dimensions.
if lower.
All dimensions for reference only and subject to change. Figure 2
For prompt service, Parker Autoclave Engineers stocks select products.
Consult your local representative.
D HEX
F
C
E
A
Tee
Figure 3
D HEX
F
C
E
A
B
Cross
All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold. 3
Outside Pressure Dimensions - inches (mm)
Catalog Connection Minimum Block Fitting
Diameter Rating Opening A B C D E F G Thickness
Number Type Pattern
Tube psi (bar)* Typical Thickness
Bulkhead Coupling
20BFX4466 SF250CX 1/4 20,000 0.125 0.81 1.88 0.38 0.50 0.53 1.00 0.38
(6.35) (1378.93) (3.18) (20.57) (47.75) (9.53) (12.70) (13.46) (25.40) (9.53)
20BFX6666 SF375CX 3/8 20,000 0.219 0.94 2.00 0.44 0.62 0.62 1.00 0.38
(9.53) (1378.93) (5.56) (23.88) (50.80) (11.10) (15.75) (15.75) (25.40) (9.53)
20BFX9966 SF562CX 9/16 20,000 0.359 1.12 2.38 0.53 0.94 0.78 1.38 0.38
(14.29) (1378.93) (9.12) (28.45) (60.45) (13.46) (23.88) (19.81) (35.05) (9.53) See
20BFX12 SF750CX 3/4 20,000 0.516 1.69 2.62 0.62 1.19 0.91 1.88 0.38 Figure 5
(19.05) (1378.93) (13.11) (42.93) (66.55) (15.75) (30.23) (23.11) (47.75) (9.53)
20BFX16 SF1000CX 1 20,000 0.688 1.94 3.50 0.72 1.38 1.50 1.88+ 0.38
(25.40) (1378.93) (17.48) (49.28) (88.90) (18.29) (35.05) (38.10) (47.75) (9.53)
15BFX24 SF1500CX 1-1/2 15,000 0.94 2.44 5.00 1.12 1.88 2.00 2.50+ 0.38
(38.10) (1034.20) (23.80) (61.85) (127.00) (28.45) (47.63) (50.80) (63.50) (9.53)
*Maximum pressure rating is based on the lowest rating of any Union Couplings are designed with a removable seat insert
component. Actual working pressure may be determined by tubing allowing disassembly and tubing removal without the necessity of
pressure rating, if lower. loosening other items in a line.
+ distance across flats
All dimensions for reference only and subject to change.
For prompt service, Parker Autoclave Engineers stocks select
products. Consult your local representative.
Figure 4
A HEX
D
HEX
B C
Figure 5
G MAX
F D
HEX HEX A
E
B C
(A=Panel hole drill size)
Bulkhead Coupling
4 All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold.
Medium Pressure Tubing
Pressures to 20,000 psi (1379 bar)
Catalog Tube Fits Tube Size Inches (mm) Flow Working Pressure psi (bar)*
Number Material Connection Outside Inside Wall Area -423 to 100F 200F 400F 600F 800F
Type Diameter Diameter Thickness in.2 (mm2) -252 to 37.8C 93C 204C 316C 427C
Note: Caution should be exercised in proper selection of Medium Pressure Tubing based on actual operating conditions. Two series available: 15,000 psi (1034 bar) and 20,000 psi (1379 bar).
*Maximum pressure rating is based on the lowest rating of any component.
Actual working pressure may be determined by tubing pressure rating, if lower.
All dimensions for reference only and subject to change.
For prompt service, Parker Autoclave Engineers stocks select products. Consult your local representative.
All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold. 5
Medium Pressure Coned-and-Threaded Nipples
Pressures to 20,000 psi (1379 bar)
Special lengths
In addition to the standard lengths listed in the table below,
nipples are available in any custom length. Consult factory.
Materials**
Catalog numbers in table refer to Type 316 Stainless steel.
Optional materials available. Consult factory.
CNX4402-316 CNX4403-316 CNX4404-316 CNX4406-316 CNX4408-316 CNX44010-316 CNX44012-316 SF250CX 1/4 0.109 20,000
(6.35) (2.77) (1378.93)
CNX6603-316 CNX6604-316 CNX6606-316 CNX6608-316 CNX66010-316 CNX66012-316 SF375CX 3/8 0.203 20,000
(9.53) (5.16) (1378.93)
Note: Caution should be exercised when selecting medium pressure nipples since two series
are available: 15,000 psi (1034.16 bar) and 20,000 psi (1379 bar)
6 All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold.
Medium Pressure Check Valves
Pressures to 20,000 (1379 bar)
Ball Check Valves Prevents reverse flow where leak-tight shut-off is not manda-
tory. When differential drops below cracking pressure, valve
closes. With all-metal components, valve can be used up to
1200F (649C). See Technical Information section for con-
nection temperature limitations. (Not for use as a relief valve.)
The ball and poppet are an integral design to assure
positive, in-line seating without chatter. Poppet is designed
essentially for axial flow with minimum pressure drop.
FLOW Materials: 316 Stainless Steel: body, cover, ball poppet,
cover gland. 300 Series Stainless Steel: ball, spring.
Minimum operating temperature for standard ball check
valves -110F (-79C).
For low temperature option to -423F (-252C) add suffix
LT (Low temperature spring).
Protects pressure gauges and pressure instrumentation from
Ball Type Excess Flow Valves surges in flow or sudden venting in the event of line failure.
Materials: 316 Stainless Steel: body, cover, sleeve, cover
gland. 300 Series Stainless Steel: ball.
Vertical Installation: Since this type of check valve employs a
non-spring loaded ball, valve MUST be installed in VERTICAL
position with arrow on valve body pointing UP. (cover gland up).
Resetting Valve: Equalize the pressure across the ball. The
ball will drop and reset automatically.
(Vertical Installation Only)
CAUTION: While testing has shown O-Rings to provide satisfactory service life, both cyclic and shelf
life may vary widely with differing service conditions, properties of reactants, pressure and temperature
FLOW
cycling and age of the O-ring. FREQUENT INSPECTIONS SHOULD BE MADE to detect any deterioration,
and O-rings replaced as required.
NOTE: Special material check valves may be supplied with four flats in place of standard hex.
All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold. 7
Medium Pressure Check Valves
Figure 1
A
B
D HEX
HEX
C C
8 All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold.
Medium Pressure Line Filters
Pressures to 20,000 psi (1379 bar)
NOTE 1: All filters furnished complete with connection components unless otherwise specified. All
dimensions for reference only and subject to change.
NOTE 2: Parker Autoclave Engineers disc and cup type filters are designed to filter small amounts of
process particles. It is recommended that all fluids are thoroughly cleaned prior to entering the higher
pressure system.
NOTE 3: Special material filters may be supplied with four flats in place of standard hex.
NOTE 4: Pressure differential not to exceed 1,000 psi (69 bar) in a flowing condition.
NOTE 5: Larger micron size filter element is installed on the upstream (inlet) side.
All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold. 9
Pressure Orifice Connection Effective Filter Dimensions - inches (mm)
Catalog Micron Element
Rating inches Size and A B C D Hex
Number Size** Area
psi (bar)* (mm) Type in.2 (mm2) Typical
CLFX9900-5/10 20,000 0.312 5/10 SF562CX 0.25 4.94 2.68 0.53 .94 1.38
(1378.93) (7.92) (161.29) (125.48) (68.07) (13.46) (23.88) (35.05)
A
D
B HEX
C C
HEX
A
B
HEX D HEX
C C
10 All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold.
Anti-Vibration Collet Gland Assembly
Pressures to 20,000 psi (1379 bar)
All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold. 11
WARNING
FAILURE, IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS AND/OR SYSTEMS DESCRIBED HEREIN OR RELATED ITEMS CAN CAUSE DEATH, PERSONAL INJURY AND PROPERTY DAMAGE.
This document and other information from Parker Hannifin Corporation, its subsidiaries and authorized distributors provide product and/or system options for further investigation by users having technical
expertise. It is important that you analyze all aspects of your application and review the information concerning the product or system in the current product catalog. Due to the variety of operating conditions
and applications for these products or systems, the user, through its own analysis and testing, is solely responsible for making the final selection of the products and systems and assuring that all performance,
safety and warning requirements of the application are met. The products described herein, including without limitation, product features, specifications, designs, availability and pricing, are subject to change by
Parker Hannifin Corporation and its subsidiaries at any time without notice.
Offer of Sale
The items described in this document are available for sale by Parker Hannifin Corporation, its subsidiaries or its authorized distributors. Any sale contract entered by Parker will be governed by the provisions
stated in Parker's standard terms and conditions of sale (copy available upon request).
2013 Parker Hannifin Corporation | Autoclave Engineers is a registered trademark of the Parker Hannifin Corporation 02-0124SE January2013
Instrumentation Products Division Parker Hannifin Manufacturing Ltd. Caution! Parker Autoclave Engineers Valves, Fittings and Tools are
not designed to work with common commercial instrument tubing
Autoclave Engineers Operation Instrumentation Products Division, Europe
and will only work with tubing built to Parker Autoclave Engineers
8325 Hessinger Drive Industrial Estate Whitemill
AES Specifications. Failure to do so will void warranty.
Erie, Pennsylvania 16509-4679 USA Wexford, Republic of Ireland
PH: 814-860-5700 FAX: 814-860-5811 PH: 353 53 914 1566
www.autoclave.com FAX: 353 53 914 1582 ISO-9001 Certified
Fittings and Tubing
QS Series
Medium Pressure
The Medium Pressure QS Series uses Parker Autoclave Engineers' Quick Set compression sleeve
design. This single-ferrule compression sleeve connection delivers fast, easy make-up and reli-
able bubble-tight performance in liquid or gas service.
Medium Pressure
www.autoclave.com
2
Fittings and Tubing - QS Series
Pressures to 15,000 psi (1034 bar)
Parker Autoclave Engineers Medium Pressure QS Fittings are
designed for use with QS Series valves and medium pressure tub-
ing. These fittings feature improved compression connections with
larger orifices for excellent flow capabilities. Parker Autoclave
Engineers fittings and components are manufactured of high
strength stainless steel.
Connection Components
All Parker Autoclave Engineers valves and fittings are supplied complete with appropriate glands and sleeves. To order these
components separately, use order numbers listed. When using plug, sleeve is not required.
Add tube size ( ) Example: To ensure proper fit use Parker Autoclave Engineers tubing.
1/4 - 40 1/4 Gland - QSG 40 For mounting hole option add suffix PM to catalog number.
3/8 - 60 Consult factory for mounting hole dimensions.
9/16 - 90
3/4 - 120
1" - 160
Elbow
QSL4400 QS250 1/4 15,000 0.16 1.38 2.00 0.52 0.63 1.00 1.00 0.75
(6.35) (1034.20) (3.99) (34.93) (50.80) (13.23) (15.88) (25.40) (25.40) (19.05)
QSL6600 QS375 3/8 15,000 0.25 1.50 2.00 0.55 0.75 1.00 1.00 0.81
(9.53) (1034.20) (6.35) (38.10) (50.80) (14.00) (19.05) (25.40) (25.40) (20.62)
QSL9900 QS562 9/16 15,000 0.36 2.19 3.00 0.82 1.19 1.50 1.50 1.25 See
(14.29) (1034.20) (9.12) (55.58) (76.20) (20.83) (30.18) (38.10) (38.10) (31.75) Figure 1
QSL12 QS750 3/4 15,000 0.52 2.94 4.13 1.04 1.50 2.06 2.06 1.50
(19.05) (1034.20) (13.11) (74.63) (104.78) (26.37) (38.10) (52.40) (52.40) (38.10)
QSL16 QSF1000 1 15,000 0.688 3.5 4.75 1.19 1.75 2.38 2.38 2.00
(25.4) (1034.20) (17.48) (88.90) (120.65) (30.18) (44.45) (60.33) (60.33) (50.80)
E
A
B
3
Elbow
Outside Pressure Dimensions - inches (mm)
Catalog Connection Minimum Block Fitting
Diameter Rating Opening A B C D E F G Thickness
Number Type Pattern
Tube psi (bar)* Typical Thickness
Tee
QST4440 QS250 1/4 15,000 0.16 1.38 2.00 0.52 0.63 1.00 1.00 0.75
(6.35) (1034.20) (3.99) (34.93) (50.80) (13.23) (15.88) (25.40) (25.40) (19.05)
QST6660 QS375 3/8 15,000 0.25 1.50 2.00 0.55 0.75 1.00 1.00 0.81
(9.53) (1034.20) (6.35) (38.10) (50.80) (14.00) (19.05) (25.40) (25.40) (20.62)
QST9990 QS562 9/16 15,000 0.36 2.19 3.00 0.82 1.19 1.50 1.50 1.25
See
(14.29) (1034.20) (9.12) (55.58) (76.20) (20.83) (30.18) (38.10) (38.10) (31.75) Figure 2
QST12 QS750 3/4 15,000 0.52 2.94 4.13 1.04 1.50 2.06 2.06 1.50
(19.05) (1034.20) (13.11) (74.63) (104.78) (26.37) (38.10) (52.40) (52.40) (38.10)
QST16 QSF1000 1 15,000 0.688 3.50 4.75 1.19 1.75 2.38 2.38 2.00
(25.4) (1034.20) (17.48) (88.90) (120.65) (30.18) (44.45) (60.33) (60.33) (50.80)
Cross
QSX4444 QS250 1/4 15,000 0.16 2.00 2.00 0.52 0.63 1.00 1.00 0.75
(6.35) (1034.20) (3.99) (50.80) (50.80) (13.23) (15.88) (25.40) (25.40) (19.05)
QSX6666 QS375 3/8 15,000 0.25 2.00 2.00 0.55 0.75 1.00 1.00 0.81
(9.53) (1034.20) (6.35) (50.80) (50.80) (14.00) (19.05) (25.40) (25.40) (20.62)
QSX9999 QS562 9/16 15,000 0.36 3.00 3.00 0.82 1.19 1.50 1.50 1.25 See
(14.29) (1034.20) (9.12) (76.20) (76.20) (20.83) (30.18) (38.10) (38.10) (31.75) Figure 3
QSX12 QS750 3/4 15,000 0.52 4.13 4.13 1.04 1.50 2.06 2.06 1.50
(19.05) (1034.20) (13.11) (104.78) (104.78) (26.37) (38.10) (52.40) (52.40) (38.10)
QSX16 QSF1000 1 15,000 0.688 4.75 4.75 1.19 1.75 2.38 2.38 2.00
(25.4) (1034.20) (17.48) (120.65) (104.78) (30.18) (44.45) (60.33) (60.33) (50.80)
For mounting hole option add suffix PM to catalog number. Consult factory for mounting hole dimensions.
1" QS fitting bodies are 2507 Super Duplex
Figure 2 Figure 3
F
D HEX C
F
C E
D
HEX A
E
A
B
B
Tee Cross
Straight Coupling
15F44QQ QS250 1/4 15,000 0.16 0.75 1.63 0.52 0.63 Straight
(6.35) (1034.20) (3.99) (19.05) (41.28) (13.23) (15.88)
15F66QQ QS375 3/8 15,000 0.25 0.81 1.75 0.55 0.75 Straight
(9.53) (1034.20) (6.35) (20.65) (44.45) (14.00) (19.05) See
15F99QQ QS562 9/16 15,000 0.36 1.38 2.75 0.82 1.19 Straight
(14.29) (1034.20) (9.12) (34.93) (69.85) (20.83) (30.18) Figure 4
15F12Q QS750 3/4 15,000 0.52 1.50 3.75 1.04 1.50 Straight
(19.05) (1034.20) (13.11) (38.10) (95.25) (26.37) (38.10)
15F16Q QSF1000 1 15,000 0.688 2.75 4.50 1.19 1.75 Straight
(25.4) (1034.20) (17.48) (69.85) (114.30) (30.23) (44.45)
Bulkhead Coupling
15BF44QQ QS250 1/4 15,000 0.16 0.88 2.00 0.52 0.63 0.63 1.00 0.38
(6.35) (1034.20) (3.99) (22.23) (50.80) (13.23) (15.88) (15.88) (25.40) (9.53)
15BF66QQ QS375 3/8 15,000 0.25 1.06 2.38 0.55 0.75 0.79 1.38 0.38
(9.53) (1034.20) (6.35) (27.00) (60.33) (14.00) (19.05) (19.94) (34.93) (9.53)
15BF99QQ QS562 9/16 15,000 0.36 1.63 2.63 0.82 1.19 0.91 1.75 0.38 See
(14.29) (1034.20) (9.12) (41.40) (66.68) (20.83) (30.18) (22.99) (44.45) (9.53) Figure 5
15BF12Q QS750 3/4 15,000 0.52 1.88 3.50 1.04 1.50 1.50 2.13 0.38
(19.05) (1034.20) (13.11) (47.63) (88.90) (26.37) (38.10) (38.10) (53.98) (9.53)
15BF16Q QSF1000 1 15,000 0.688 2.38 5.00 1.19 1.75 2.00 1.88 0.38
(25.4) (1034.20) (17.48) (60.33) (127.00) (30.23) (44.45) (50.80) (47.63) (9.53)
*Maximum pressure rating is based on the lowest rating of any component. All dimensions for reference only and subject to change. Union Couplings are designed with a removable seat insert
Actual working pressure may be determined by tubing pressure rating, For prompt service, Parker Autoclave Engineers stocks select allowing disassembly and tubing removal without the necessity of
if lower. products. Consult your local representative. loosening other items in a line.
1" QS fitting bodies are 2507 Super Duplex
D D A
HEX F
HEX
B C
E
B C
Catalog Tube Fits Tube Size Inches (mm) Flow Working Pressure psi (bar)*
Number Material Connection Outside Inside Wall Area -425 to 100F 200F 400F 600F
Type Diameter Diameter Thickness in.2 (mm2) -252 to 37.8C 93C 204C 316C
MS15-098 316SS QS750 3/4 0.516 0.117 0.209 15,000 15,000 14,400 13,650
(19.05) (13.11) (2.97) (134.84) (1034.19) (1034.19) (992.82) (941.12)
MS15-099 316SS QS1000 1 0.688 0.156 0.371 15,000 15,000 14,400 13,650
(25.4) (17.48) (3.96) (239.35) (1034.16) (1034.16) (992.83) (941.12)
5
Nipples - QS Series
Pressures to 15,000 psi (1034 bar)
Elbow Tube
Size Fits Connection Dimension H Mean Radius R Inside Radius Ri
Model Type Inches (mm)
Inches (mm) Inches (mm) Inches (mm)
QTE44-90 1/4 (6.35) QS250 3.25 (82.55) 0.563 (14.30) 0.438 (11.13)
QTE66-90 3/8 (9.53) QS375 3.50 (88.90) 0.938 (23.83) 0.75 (19.05)
QTE99-90 9/16 (14.29) QS562 7.50 (19.05) 2.906 (73.82) 2.625 (66.68)
QTE12-90 3/4 (19.05) QS750 10.00 (254.00) 3.875 (98.43) 3.5 (88.9)
QTE16-90 1 (25.40) QS1000 11.50 (292.10) 5.125 (13.30) 4.625 (117.48)
Ri
H Typ.
6
Check Valves - QS Series
Pressures to 15,000 psi (1034 bar)
O-Ring Check Valves Provide unidirectional flow and tight shut-off for liquids and
gases with high reliability. When differential drops below crack-
ing pressure*, valve shuts off. (Not for use as relief valve.)
Materials: 316 Stainless Steel: Body, cover, poppet, cover
gland. 300 Stainless Steel: Spring. Except 1" - see note below.
Standard O-ring: Viton, for operation to 400 F (204C).
Buna-N or PTFE available for 250F (121C) or 400F (204C)
respectively; specify when ordering.
FLOW
*Cracking Pressure: 20 psi (1.38 bar) 30%. Springs for
higher cracking pressures (up to 100 psi (6.89bar)) available
Minimum operating temperature for standard o-ring check valves 0F (-17.8C) on special order for O-ring style check valves only.
Ball Check Valves
Prevent reverse flow where leak-tight shut-off is not
mandatory. When differential drops below cracking pressure,
valve closes. With all-metal components, valve can be used up
to 650F (343C). See Technical Information section for con-
nection temperature limitations. (Not for use as a relief valve.)
Ball and poppet are an integral design to assure positive,
in-line seating without chatter. Poppet is designed essentially
FLOW for axial flow with minimum pressure drop.
Materials: 316 Stainless Steel: Body, cover, cover gland, ball
Minimum operating temperature for standard o-ring check valves 0F (-17.8C) poppet. 300 Series Stainless Steel: Spring. Except 1" - see note
below.
CAUTION: While testing has shown O-Rings to provide satisfactory service life, both cyclic and shelf life may vary widely with differing service conditions, properties of reactants, pressure and temperature cycling
and age of the O-ring. FREQUENT INSPECTIONS SHOULD BE MADE to detect any deterioration, and O-rings replaced as required.
Offer of Sale
The items described in this document are available for sale by Parker Hannifin Corporation, its subsidiaries or its authorized distributors. Any sale contract entered by Parker will be governed by the provisions
stated in Parker's standard terms and conditions of sale (copy available upon request).
2013 Parker Hannifin Corporation | Autoclave Engineers is a registered trademark of the Parker Hannifin Corporation 02-1247BE January2013
Instrumentation Products Division Parker Hannifin Manufacturing Ltd. Caution! Parker Autoclave Engineers Valves, Fittings and Tools are
Autoclave Engineers Operation Instrumentation Products Division, Europe not designed to work with common commercial instrument tubing
and will only work with tubing built to Parker Autoclave Engineers
8325 Hessinger Drive Industrial Estate Whitemill
AES Specifications. Failure to do so will void warranty.
Erie, Pennsylvania 16509-4679 USA Wexford, Republic of Ireland
PH: 814-860-5700 FAX: 814-860-5811 PH: 353 53 914 1566
www.autoclave.com FAX: 353 53 914 1582 ISO-9001 Certified
Fittings, Tubing & Nipples
High Pressure
Pressures to 150,000 psi (10342 bar)
Coned-and-Threaded Connection.
Available sizes are 1/4, 5/16, 3/8, 9/16, and 1.
Fittings manufactured from 316 cold worked or high strength stainless steel.
Tubing is manufactured from dual rated 316/316L and 304/304L cold worked
stainless steel.
Operating Temperatures from -423F (-252C) to 1200F (649C).
Anti-vibration connection components available.
Ultra-high pressure components.
Autofrettaged tubing.
High pressure high cycle tubing.
The high and ulta-high pressure series uses Parker Autoclave Engineers' high pressure con-
nector. This coned-and-threaded connection provides dependable performance in gas or liquid
service.
www.autoclave.com
Pressures to 150,000 psi (10342 bar)
Connection Components
All Parker Autoclave Engineers valves and fittings are supplied complete with appropriate glands and collars. To order these components sepa-
rately, use order numbers listed. When using plug, collar is not required.
Add tube size ( ) Example: To ensure proper fit use Parker Autoclave Engineers tubing.
1/4 - 40 9/16 Gland - AGL (90)
5/16 - 50
3/8 - 60 Note: Special material glands may be supplied with four flats in place
9/16 - 90 of standard hex.
1 - 160
F250C AGL( ) ACL( ) AP( ) Parker Autoclave Engineers high pressure fittings 1/4, 3/8 and
F375C 9/16 connection components to 60,000 psi (4137 bar).
F562C For use with 30VM, 40VM, 60VM valves and fittings.
F1000C43 CGLX160 CCLX160 43CP160 Parker Autoclave Engineers high pressure 1 connection
components to 43,000 psi (2965 bar) for use with 30SC, 43Y
valves, and fittings.
CGL50 CCL50 CP50 Parker Autoclave Engineers ultra high pressure 5/16
connection components to 150,000 psi ( 10342 bar) for use
with 100VM and 150V valve and fittings.
F312C150
100CGL40 100CCL40 100CP40 Parker Autoclave Engineers 100,000 psi (6895 bar) connection
100CGL60 100CCL60 100CP60 components utilize our 5/16" connection for 1/4" and 3/8"
tubing. (See Note*)
2 All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold.
Outside Pressure Dimensions - inches (mm)
Catalog Connection Minimum Block Fitting
Diameter Rating Opening A B C D E F G Thickness
Number Type Pattern
Tube psi (bar)* Typical Thickness
Elbow
CL4400 F250C 1/4 60,000 0.094 1.00 1.50 0.50 0.63 0.62 0.88 0.75
(6.35) (4136.79) (2.39) (25.40) (38.10) (12.70) (15.88) (15.75) (22.35) (19.05)
100CL4400 F312C150 1/4 100,000 0.094 2.12 3.00 0.52 0.75 1.50 1.50 1.38
(6.35) (6894.65) (2.39) (53.85) (76.20) (13.21) (19.05) (38.10) (38.10) (35.05)
CL5500 F312C150 5/16 150,000 0.094 2.12 3.00 0.52 0.75 1.50 1.50 1.38
(7.94) (10341.97) (2.39) (53.85) (76.20) (13.21) (19.05) (38.10) (38.10) (35.05)
CL6600 F375C 3/8 60,000 0.125 1.50 2.00 0.52 0.81 1.00 1.25 1.00
(9.53) (4136.79) (3.18) (38.10) (50.80) (13.21) (20.62) (25.40) (31.75) (25.40) See
100CL6600 F312C150 3/8 100,000 0.094 2.12 3.00 0.52 0.75 1.50 1.50 1.38 Figure 1
(9.53) (6894.65) (2.39) (53.85) (76.20) (13.21) (19.05) (38.10) (38.10) (35.05)
CL9900 F562C 9/16 60,000 0.188 1.88 2.62 0.81 1.19 1.12 1.88 1.50
(14.29) (4136.79) (4.78) (47.75) (66.55) (20.57) (30.23) (28.45) (47.75) (38.10)
40CL9900 F562C40 9/16 40,000 0.250 1.88 2.62 0.81 1.19 1.12 1.88 1.50
(14.29) (2757.86) (6.35) (47.775) (66.55) (20.57) (30.23) (28.45) (47.75) (38.10)
43CL16 F1000C43 1 43,000 0.438 3.00 4.12 0.72 1.38 2.06 2.06 1.75
(25.40) (2964.70) (11.13) (76.20) (104.65) (18.29) (35.05) (52.32) (52.32) (44.45)
Tee
CT4440 F250C 1/4 60,000 0.094 1.25 2.00 0.50 0.63 0.88 1.00 1.00
(6.35) (4136.79) (2.39) (31.75) (50.80) (12.70) (15.88) (22.35) (25.40) (25.40)
100CT4440 F312C150 1/4 100,000 0.094 2.12 3.00 0.52 0.75 1.50 1.50 1.38
(6.35) (6894.65) (2.39) (53.85) (76.20) (13.21) (19.05) (38.10) (38.10) (35.05)
CT5550 F312C150 5/16 150,000 0.094 2.12 3.00 0.52 0.75 1.50 1.50 1.38
(7.94) (10341.97) (2.39) (53.85) (76.20) (13.21) (19.05) (38.10) (38.10) (35.05)
CT6660 F375C 3/8 60,000 0.125 1.56 2.00 0.52 0.81 1.06 1.00 1.00
(9.53) (4136.79) (3.18) (39.62) (50.80) (13.21) (20.62) (26.92) (25.40) (25.40) See
100CT6660 F312C150 3/8 100,000 0.094 2.12 3.00 0.52 0.75 1.50 1.50 1.38 Figure 2
(9.53) (6894.65) (2.39) (53.85) (76.20) (13.21) (19.05) (38.10) (38.10) (35.05)
CT9990 F562C 9/16 60,000 0.188 2.12 2.62 0.81 1.19 1.38 1.31 1.50
(14.29) (4136.79) (4.78) (53.85) (66.55) (20.57) (30.23) (35.05) (33.27) (38.10)
40CT9990 F562C40 9/16 40,000 0.250 2.12 2.62 0.81 1.19 1.38 1.31 1.50
(14.29) (2757.86) (6.35) (53.85) (66.55) (20.57) (30.23) (35.05) (33.27) (38.10)
43CT16 F1000C43 1 43,000 0.438 3.00 4.12 0.72 1.38 2.06 2.06 1.75
(25.40) (2964.70) (11.13) (76.20) (104.65) (18.29) (35.05) (52.32) (52.32) (44.45)
Cross
CX4444 F250C 1/4 60,000 0.094 1.25 2.00 0.50 0.63 0.62 1.00 1.00
(6.35) (4136.79) (2.39) (31.75) (50.80) (12.70) (15.88) (15.75) (25.40) (25.40)
100CX4444 F312C150 1/4 100,000 0.094 3.00 3.00 0.52 0.75 1.50 1.50 1.38
(6.35) (6894.65) (2.39) (76.20) (76.20) (13.21) (19.05) (38.10) (38.10) (35.05)
CX5555 F312C150 5/16 150,000 0.094 3.00 3.00 0.52 0.75 1.50 1.50 1.38
(7.94) (10341.97) (2.39) (76.20) (76.20) (13.21) (19.05) (38.10) (38.10) (35.05)
CX6666 F375C 3/8 60,000 0.125 2.12 2.00 0.52 0.81 1.06 1.00 1.00
(9.53) (4136.79) (3.18) (53.85) (50.80) (13.21) (20.62) (26.92) (25.40) (25.40) See
100CX6666 F312C150 3/8 100,000 0.094 2.12 3.00 0.52 0.75 1.50 1.50 1.38 Figure 3
(9.53) (6894.65) (2.39) (76.20) (76.20) (13.21) (19.05) (38.10) (38.10) (35.05)
CX9999 F562C 9/16 60,000 0.188 2.75 2.62 0.81 1.19 1.38 1.31 1.50
(14.29) (4136.79) (4.78) (69.85) (66.55) (20.57) (30.23) (35.05) (33.27) (38.10)
40CX9999 F562C40 9/16 40,000 0.250 2.75 2.62 0.81 1.19 1.38 1.31 1.50
(14.29) (2757.86) (6.35) (69.85) (66.55) (20.57) (30.23) (35.05) (33.27) (38.10)
43CX16 F1000C43 1 43,000 0.438 4.12 4.12 0.72 1.38 2.06 2.06 1.75
(25.40) (2964.70) (11.13) (104.65) (104.65) (18.29) (35.05) (52.32) (52.32) (44.45)
*Maximum pressure rating is based on the lowest rating of any component. All dimensions for reference only and subject to change.
Actual working pressure may be determined by tubing pressure rating, if lower. For prompt service, Parker Autoclave stocks select products. Consult your local representative.
D HEX F F
F C
C
C
D HEX E
E D
E A HEX
A
A
B
B
B
Elbow Tee Cross
Note: Fittings such as 45 elbows, reducer elbows, and reducer 45 elbows are available upon request. For mounting hole option add suffix PM to catalog number, consult factory for
mounting hole dimensions. Contact your local sales representative for additional information.
All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold. 3
Outside Pressure Dimensions - inches (mm)
Catalog Connection Minimum Block Fitting
Diameter Rating Opening A B C D E F G Thickness
Number Type Pattern
Tube psi (bar)* Typical Hex Thickness
Bulkhead Coupling
60BF4433 F250C 1/4 60,000 0.094 0.94 1.88 0.50 0.63 0.50 1.00 0.38
(6.35) (4136.79) (2.39) (23.88) (47.75) (12.70) (15.88) (12.70) (25.40) (9.65)
100BF4433 F312C150 1/4 100,000 0.094 2.12 3.25 0.52 0.75 1.38 2.00 0.38
(6.35) (6894.65) (2.39) (53.85) (82.55) (13.21) (19.05) (35.05) (50.80) (9.65)
150BF5533 F312C150 5/16 150,000 0.094 2.12 3.25 0.52 0.75 1.38 2.00 0.38
(7.94) (10341.97) (2.39) (53.85) (82.55) (13.21) (19.05) (35.05) (50.80) (9.65)
60BF6633 F375C 3/8 60,000 0.125 1.12 2.38 0.53 0.81 0.78 1.38 0.38
(9.53) (4136.79) (3.18) (28.45) (60.45) (13.46) (20.62) (19.81) (35.05) (9.65) See
100BF6633 F312C150 3/8 100,000 0.094 2.12 3.25 0.52 0.75 1.38 2.00 0.38 Figure 5
(9.53) (6894.65) (2.39) (53.85) (82.55) (13.21) (19.05) (35.05) (50.80) (9.65)
60BF9933 F562C 9/16 60,000 0.188 1.69 2.75 0.81 1.19 1.00 1.88 0.38
(14.29) (4136.79) (4.78) (42.93) (69.85) (20.57) (30.23) (25.40) (47.75) (9.65)
40BF9933 F562C40 9/16 40,000 0.250 1.69 2.75 0.81 1.19 1.00 1.88 0.38
(14.29) (2757.86) (6.35) (42.93) (69.85) (20.57) (30.23) (25.40) (47.75) (9.65)
43BF16 F1000C43 1 43,000 0.438 1.94 3.50 0.72 1.38 1.50 2.13 0.50
(25.40) (2964.70) (11.13) (49.28) (88.90) (18.29) (35.05) (38.10) (54.10) (12.70)
*Maximum pressure rating is based on the lowest rating of any component. Union Couplings are designed with a removable seat insert
Actual working pressure may be determined by tubing pressure rating, if lower. allowing disassembly and tubing removal without the necessity of
loosening other items in a line.
All dimensions for reference only and subject to change.
For prompt service, Parker Autoclave Engineers stocks select products. Consult your local representative.
Figure 4 Figure 5
G MAX
A HEX
D F A D HEX
HEX
B C E
B C
4 All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold.
High Pressure Tubing
Pressures to 150,000 psi (10342 bar)
Catalog Tube Fits Tube Size Inches (mm) Flow Working Pressure psi (bar)*
Number Material Connection Outside Inside Wall Area -423 to 100F 200F 400F 600F 800F
Type Diameter Diameter Thickness in. (mm2)
2
-252 to 37.8C 93C 204C 316C 427C
Note:
1. Autofrettaged tubing available (see technical Information section: Pressure Cycling *Maximum pressure rating is based on the lowest rating of any component.
for Autofrettage information) Actual working pressure may be determined by tubing pressure rating, if lower.
2. For HighPressure, High Cycle (HPHC) tubing, MS15-201, MS15-202, MS15-209,
All dimensions for reference only and subject to change.
and MS15-210 are available. (See Technical Information section: Pressure Cycling
For prompt service, Parker Autoclave Engineers stocks select products. Consult your local representative.
for additional information)
3. For 100,000 psi rating use F312C150 connection
All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold. 5
High Pressure Coned-and-Threaded Nipples
Pressures to 150,000 psi (10342 bar)
Special lengths
In addition to the standard lengths listed in the table below,
nipples are available in any custom length. Consult factory.
Materials**
Catalog numbers in table refer to Type 316 Stainless steel.
Note: Most items available in 304SS. Consult factory for availability.
CN4402-316 CN4403-316 CN4404-316 CN4406-316 CN4408-316 CN44010-316 CN44012-316 F250C 1/4 0.083 60,000
(6.35) (2.11) (4136.79)
CN6603-316 CN6604-316 CN6606-316 CN6608-316 CN66010-316 CN66012-316 F375C 3/8 0.125 60,000
(9.53) (3.18) (4136.79)
Note:
See High pressure tubing section for pressure ratings at various temperatures.
6 All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold.
High Pressure Check Valves
Pressures to 60,000 psi (4137 bar)
Ball Check Valves Prevents reverse flow where leak-tight shut-off is not manda-
tory. When differential drops below cracking pressure, valve
closes. With all-metal components, valve can be used up
to 1200F (649C). See Technical Information section for
connection temperature limitations. (Not for use as a relief
valve.)
Ball and poppet are an integral design to assure positive, in-
line seating without chatter. Poppet is designed essentially
FLOW
for axial flow with minimum pressure drop.
Materials: 316 Stainless Steel: body, cover, ball poppet,
Minimum operating temperature for standard ball check cover gland. 300 Series Stainless Steel: spring.
valves -110F (-79C).
For low temperature option to -423F (-252C) add suffix
LT (Low temperature spring).
Ball Type Excess Flow Valves Protects pressure gauges and pressure instrumentation from
surges in flow or sudden venting in the event of line failure.
Materials: 316 Stainless Steel: body, cover, sleeve, cover
gland. 300 Series Stainless Steel: ball.
Vertical Installation: Since this type of check valve employs a
non-spring loaded ball, valve MUST be installed in VERTICAL
position with arrow on valve body pointing UP. (cover gland up).
Resetting Valve: Equalize the pressure across the ball. The
ball will drop and reset automatically.
(Vertical Installation Only)
CAUTION: While testing has shown O-Rings to provide satisfactory service life, both cyclic and shelf
life may vary widely with differing service conditions, properties of reactants, pressure and temperature
cycling and age of the O-ring. FREQUENT INSPECTIONS SHOULD BE MADE to detect any deterioration,
FLOW
All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold.
7
High Pressure Check Valves
Figure 1
A
B
HEX D HEX
C C
8 All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold.
High Pressure Line Filters
Pressures to 60,000 psi (4137 bar)
NOTE 1: All filters furnished complete with connection components unless specified without.
All dimensions for reference only and subject to change.
NOTE 2: Parker Autoclave Engineers disc and cup type filters are designed to filter small amounts of
process particles. It is recommended that all fluids are thoroughly cleaned prior to entering the higher
pressure system.
NOTE 3: Special material filters may be supplied with four flats in place of standard hex.
NOTE 4: Pressure differential not to exceed 1,000 psi (69 bar) in a flowing condition.
NOTE 5: Larger micron size filter element is installed on the upstream (inlet) side.
All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold. 9
Pressure Orifice Connection Effective Filter Dimensions - inches (mm)
Catalog Micron Element
Rating inches Size and A B C D Hex
Number Size** Area
psi (bar)* (mm) Type in.2 (mm2) Typical
Note:
**Other micron sizes available on special order. Change last digits of the catalog number accordingly.
For optional materials, see Needle Valve Options section.
A
D
B HEX
C C
HEX
A
B
HEX D HEX
C C
10 All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold.
High Anti-Vibration Collet Gland Assembly
Pressures to 150,000 psi (10342 bar)
Series KCGL
60,000 psi (4137 bar)
All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold. 11
Series KCBGLX - Sizes to 1 (25.40)
Series KCBGL - Sizes to 1/4" (6.35), 5/16" (7.94), 3/8" (9.53) Gland Nut Slotted Collet
WARNING
FAILURE, IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS AND/OR SYSTEMS DESCRIBED HEREIN OR RELATED ITEMS CAN CAUSE DEATH, PERSONAL INJURY AND PROPERTY DAMAGE.
This document and other information from Parker Hannifin Corporation, its subsidiaries and authorized distributors provide product and/or system options for further investigation by users having technical
expertise. It is important that you analyze all aspects of your application and review the information concerning the product or system in the current product catalog. Due to the variety of operating conditions
and applications for these products or systems, the user, through its own analysis and testing, is solely responsible for making the final selection of the products and systems and assuring that all performance,
safety and warning requirements of the application are met. The products described herein, including without limitation, product features, specifications, designs, availability and pricing, are subject to change by
Parker Hannifin Corporation and its subsidiaries at any time without notice.
Offer of Sale
The items described in this document are available for sale by Parker Hannifin Corporation, its subsidiaries or its authorized distributors. Any sale contract entered by Parker will be governed by the provisions
stated in Parker's standard terms and conditions of sale (copy available upon request).
2013 Parker Hannifin Corporation | Autoclave Engineers is a registered trademark of the Parker Hannifin Corporation 02-0125SE January2013
Instrumentation Products Division Parker Hannifin Manufacturing Ltd. Caution! Parker Autoclave Engineers Valves, Fittings and Tools are
Autoclave Engineers Operation Instrumentation Products Division, Europe not designed to work with common commercial instrument tubing
and will only work with tubing built to Parker Autoclave Engineers
8325 Hessinger Drive Industrial Estate Whitemill
AES Specifications. Failure to do so will void warranty.
Erie, Pennsylvania 16509-4679 USA Wexford, Republic of Ireland
PH: 814-860-5700 FAX: 814-860-5811 PH: 353 53 914 1566
www.autoclave.com FAX: 353 53 914 1582 ISO-9001 Certified
Fittings, Tubing & Nipples
P Series Pipe Fittings
Pressures to 15,000 psi (1034 bar)
www.autoclave.com
Pipe Fittings
Pressures to 15,000 psi (1034 bar)
Pressure Minimum
Dimensions - inches (mm)
Block
Catalog Connection Fitting
Rating Opening A B C D Thickness
Number Type Pattern
psi (bar)*
Pipe Elbow
PL4400 1/4" NPT 15,000 0.42 1.13 1.50 0.75 0.75 0.75
(1034.20) (10.67) (28.58) (38.10) (19.05) (19.05) (19.05)
PL6600 3/8" NPT 15,000 0.56 1.50 2.00 1.00 1.00 1.00
(1034.20) (14.22) (38.10) (50.80) (25.40) (25.40) (25.40)
PL8800 1/2" NPT 15,000 0.69 1.88 3.00 1.25 1.50 1.25 See
(1034.20) (17.53) (47.75) (76.20) (31.75) (38.10) (31.75) Figure 1
PL12 3/4" NPT 10,000 0.89 2.18 3.00 1.50 1.50 1.38
(689.46) (22.61) (55.37) (76.20) (38.10) (38.10) (35.05)
PL16 1" NPT 10,000 1.13 2.50 4.12 1.56 2.06 1.75
(689.46) (28.58) (63.50) (104.65) (39.67) (52.37) (44.45)
Pipe Tee
PT4440 1/4" NPT 15,000 0.42 1.13 1.50 0.75 0.75 0.75
(1034.20) (10.67) (28.58) (38.10) (19.05) (19.05) (19.05)
PT6660 3/8" NPT 15,000 0.56 1.50 2.00 1.00 1.00 1.00
(1034.20) (14.22) (38.10) (50.80) (25.40) (25.40) (25.40)
PT8880 1/2" NPT 15,000 0.69 1.88 3.00 1.25 1.50 1.25 See
(1034.20) (17.53) (47.75) (76.20) (31.75) (38.10) (31.75) Figure 2
PT12 3/4" NPT 10,000 0.89 2.18 3.00 1.50 1.50 1.38
(689.46) (22.61) (55.37) (76.20) (38.10) (38.10) (35.05)
PT16 1" NPT 10,000 1.13 2.50 4.12 1.56 2.06 1.75
(689.46) (28.58) (63.50) (104.65) (39.67) (52.37) (44.45)
Pipe Cross
PX4444 1/4" NPT 15,000 0.42 1.50 1.50 0.75 0.75 0.75
(1034.20) (10.67) (38.10) (38.10) (19.05) (19.05) (19.05)
PX6666 3/8" NPT 15,000 0.56 2.00 2.00 1.00 1.00 1.00
(1034.20) (14.22) (50.80) (50.80) (25.40) (25.40) (25.40)
PX8888 1/2" NPT 15,000 0.69 2.50 3.00 1.25 1.50 1.25 See
(1034.20) (17.53) (63.50) (76.20) (31.75) (38.10) (31.75) Figure 3
PX12 3/4" NPT 10,000 0.89 3.00 3.00 1.50 1.50 1.38
(689.46) (22.61) (76.20) (76.20) (38.10) (38.10) (35.05)
PX16 1" NPT 10,000 1.13 3.13 4.12 1.56 2.06 1.75
(689.46) (28.58) (79.38) (104.65) (39.67) (52.37) Figure
(44.45)3
*Maximum pressure rating is based on the lowest rating of any component. For prompt service, Parker Autoclave Engineers stocks select products. Consult your local representative.
Actual working pressure may be determined by pipe pressure rating, if lower. For mounting hole option add suffix PM to catalog number. Consult factory for
All dimensions for reference only and subject to change. mounting hole dimensions.
C C
C A A
A
B
B B
Elbow Tee Cross
2 All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold.
Pressure Minimum
Dimensions - in.(mm)
Catalog Connection Fitting
Rating Opening A B
Number Type Pattern
psi (bar)*
Pipe Coupling
15F4488 1/4" NPT 15,000 0.42 .075 1.50
(1034.20) (10.67) (19.05) (38.10)
15F6688 3/8" NPT 15,000 0.56 1.00 1.63
(1034.20) (14.22) (25.40) (41.28)
15F8888 1/2" NPT 15,000 0.69 1.19 2.00 See
(1034.20) (17.53) (30.23) (50.80) Figure 4
10F121288 3/4" NPT 10,000 0.89 1.38 2.75
(689.46) (22.61) (30.06) (69.90)
10F161688 1" NPT 10,000 1.13 1.75 2.50
(689.46) (28.58) (44.50) (63.50)
Pressure Minimum
Dimensions - inches (mm)
E
Catalog Connection Fitting
Rating Opening A B C D Max
Number Type Pattern
psi (bar)*
C
HEX A
A HEX
D
B
B
All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold. 3
Pressures to 15,000 (1034 bar)
Pressure Minimum
Dimensions - inches (mm)
Block
Catalog Connection Fitting
Rating Opening A B C D Thickness
Number Type Pattern
psi (bar)*
D D
D B D
B D B
B B D
B
A A
A
A
C A C
C B
C
C
D
D A HEX B
B D D
D B B
B
A
A
B C
B C
4 All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold.
A HEX
A HEX D
D B
B
Pressure Minimum
Dimensions - inches (mm)
Block
Catalog Connection Fitting
Rating Opening A B C D Thickness
Number Type Pattern
psi (bar)*
Figure 4 Figure 5
A A
C C
D
B
D
B D
B
5
Pipe Hex Nipples
Pressures to 15,000 psi (1034 bar)
Pressure Minimum
Dimensions - in.(mm) Fitting Figure 1
Catalog Connection
Rating Opening A Hex B Pattern
Number Type
psi (bar)*
6 All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold.
Pipe Check Valves
Pressures to 15,000 (1034 bar)
Special material check valves may be supplied with four flats in place of standard hex.
7
Pipe Check Valves
Pressure Minimum
Dimensions - inches (mm)
Catalog Connection Rated Fitting
Rating Opening A B C Hex D Hex
Number Type Cv Pattern
psi (bar)*
*Maximum pressure rating is based on the lowest rating of any component. All dimensions for reference only and subject to change.
+ distance across flats For prompt service, Parker Autoclave stocks select products. Consult your local representative.
WARNING
FAILURE, IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS AND/OR SYSTEMS DESCRIBED HEREIN OR RELATED ITEMS CAN CAUSE DEATH, PERSONAL INJURY AND PROPERTY DAMAGE.
This document and other information from Parker Hannifin Corporation, its subsidiaries and authorized distributors provide product and/or system options for further investigation by users having technical
expertise. It is important that you analyze all aspects of your application and review the information concerning the product or system in the current product catalog. Due to the variety of operating conditions
and applications for these products or systems, the user, through its own analysis and testing, is solely responsible for making the final selection of the products and systems and assuring that all performance,
safety and warning requirements of the application are met. The products described herein, including without limitation, product features, specifications, designs, availability and pricing, are subject to change by
Parker Hannifin Corporation and its subsidiaries at any time without notice.
Offer of Sale
The items described in this document are available for sale by Parker Hannifin Corporation, its subsidiaries or its authorized distributors. Any sale contract entered by Parker will be governed by the provisions
stated in Parker's standard terms and conditions of sale (copy available upon request).
2013 Parker Hannifin Corporation | Autoclave Engineers is a registered trademark of the Parker Hannifin Corporation 02-9222BE January2013
Instrumentation Products Division Parker Hannifin Manufacturing Ltd. Caution! Parker Autoclave Engineers Valves, Fittings and Tools are
not designed to work with common commercial instrument tubing
Autoclave Engineers Operation Instrumentation Products Division, Europe
and will only work with tubing built to Parker Autoclave Engineers
8325 Hessinger Drive Industrial Estate Whitemill AES Specifications. Failure to do so will void warranty.
Erie, Pennsylvania 16509-4679 USA Wexford, Republic of Ireland
PH: 814-860-5700 FAX: 814-860-5811 PH: 353 53 914 1566
www.autoclave.com FAX: 353 53 914 1582 ISO-9001 Certified
Adapters/Couplings
Parker Autoclave Engineers offers a complete line of
standard adapters and couplings as well as special
designs and materials.
Male/Female Adapters:
Male/female adapters are designed to join a female
connection directly to another size and/or type of
connection without the need for an additional
coupling.
Couplings:
Couplings and reducer/adapter couplings accommo-
date female-to-female joining of any combination of
standard size tubing listed.
Male/Male Adapters:
Male-to-male one piece adapters are designed to
join two female connections of any combination
listed.
QSS Male/Female Adapters:
Male/female adapters are designed to join a female
connection directly to another size and/or type of
connection without the need for an additional
coupling.
QSS Male/Male Adapters:
Male-to-male one piece adapters are designed to join two female connections of any
combination listed.
Male/Male JIC Adapters:
Male-to-male one piece adapters have one end machined with a 37 flare design.
Male/Female JIC Adapters:
Male/female adapters are designed to join a female connection directly to another size and/or
type of connection without the need for an additional coupling.
EZ-Union Adapters:
O-ring face seal adapter.
Adapters/Couplings
Flat face style o-ring seal permits easy installation or removal of components.
Butt-Weld/Header Coupling Adapters:
Female to male adapters have one end machined for butt-welding to pipe, tubes, and headers.
Bulkhead Adapters:
Male to female adapters designed for panel mounting.
SAE O-Ring Adapters:
Female to male SAE/MS straight thread o-ring seal adapter.
www.autoclave.com
Adapters/Couplings - Male/Female Adapters
Male /female adapters are designed to adapt a female connec- Other Adapters
tion to another size and/or type of connection without the need Parker Autoclave Engineers supplies many other types of
for additional couplings. In selecting an adapter involving two adapters on special order. These include socketweld to O.D.
different sized connections, the larger connection should be tube or nominal pipe size, extended or special designs.
on the male end where it is possible to maximize the mechani-
cal strength of the adapter. Materials
All Parker Autoclave Engineers adapters are precision ma-
To use this chart: chined from cold-worked Type 316 stainless steel. Other
1. Locate MALE end in vertical column. materials available on special order.
2. Locate desired FEMALE end of adapter across top of chart.
3. Catalog number of required adapter is located at
intersection of columns. Note: Special material couplings may be supplied with four flats in place of
4. For one piece adapter add-OP to suffix of part number standard hex. Pipe connections are rated 400F (204C) to -423F (-17.8C).
FEMALE END
SpeedBite Medium Pressure
Connection
Size and Type 1/8 1/4 3/8 1/2 1/4 3/8 9/16 3/4 1 1-1/2"
W125 SW250 SW375 SW500 SF250CX SF375CX SF562CX SF750CX SF1000CX SF1500CX
Fits this Pressure 15,000 15,000 15,000 10,000 20,000 20,000 20,000 20,000 20,000 15,000
Female Rating
Connection PSI (bar)* (1034.20) (1034.20) (1034.20) (689.45) (1378.93) (1378.93) (1378.93) (1378.93) (1378.93) (1034.20)
15,000
1/8 W125 (1034.20)
6M24C2 6M26C2 4M28C2 6M24C6 6M26C6 6M29C6 15M224C6
15,000
SpeedBite
1/4 SW250 (1034.20) 6M42D1 6M46D2 4M48D2 6M44D6 6M46D6 6M49D6 6M412D6
15,000
3/8 SW375 (1034.20) 6M62D1 6M64D2 4M68D2 6M64D6 6M66D6 6M69D6 6M612D6 6M616D6 15M624D6
10,000
1/2 SW500 (689.46) 4M82D1 4M84D2 4M86D2 4M84D6 4M86D6 4M89D6 4M812D6 4M816D6
20,000
1/4 SF250CX (1378.93) 15MX42K1 6MX44K2 6MX46K2 4MX48K2 20M44K6 20M46K6 20M49K6 20M412K6 20M416K6
20,000
3/8 SF375CX 15MX62K1 6MX64K2 6MX66K2 4MX68K2 20M64K6 20M66K6 20M69K6 20M612K6 20M616K6
Medium Pressure
(1378.93)
20,000
9/16 SF562CX (1378.93) 15MX92K1 6MX94K2 6MX96K2 4MX98K2 20M94K6 20M96K6 20M99K6 20M912K6 20M916K6
20,000
3/4 SF750CX (1378.93) 15MX122K1 6MX124K2 6MX126K2 4MX128K2 20M124K6 20M126K6 20M129K6 20M1212K6 20M1216K6
20,000
1 SF1000CX (1378.93) 15MX162K1 6MX164K2 6MX166K2 4MX168K2 20M164K6 20M166K6 20M169K6 20M1612K6 20M1616K6
15,000
1-1/2 SF1500CX (1034.20) 15M244K6 15M249K6 15M2412K6 15M2416K6
43,000
MALE END
1 F1000C43 (2964.69)
60,000
1/4 F250C (4136.85) 15M42B1 6M44B2 6M46B2 4M48B2 20M44B6 20M46B6 20M49B6 20M412B6
High Pressure
150,000
5/16 F312C150 (10342.14) 6M54B2 6M56B2 4M58B2 20M54B6 20M56B6 20M59B6 20M512B6
60,000
3/8 F375C (4136.85) 15M62B1 6M64B2 6M66B2 4M68B2 20M64B6 20M66B6 20M69B6 20M612B6 20M616B6
60,000
9/16 F562C (4136.85) 15M92B1 6M94B2 6M94B2 4M98B2 20M94B6 20M96B6 20M99B6 20M912B6 20M916B6
40,000
9/16 F562C40 (2757.90) 6M94G2 20M912G6
10,000
7/16 F437FB (689.45) 15M72E1 6M74E2 6M76E2 4M78E2 15M74E6 15M76E6 15M79E6
10,000
Flat Bottom
9/16 F562FB (689.45) 15M92E1 6M94E2 6M96E2 4M98E2 15M94E6 15M96E6 15M99E6 15M912E6 15M916E6
Flat Top
10,000
9/16 F562FT (689.45) 15M92R1 6M94R2 6M96R2 4M98R2 15M94R6 15M96R6 15M99R6 15M912R6 15M916R6
10,000
3/4 F750FB (689.45) 15M122E1 6M124E2 6M126E2 4M128E2 15M124E6 15M126E6 15M129E6 15M1212E6 15M1216E6
15,000
1/8 NPT (1034.20) 15M22N1 15M24N2 15M26N2 10M28N2 15M24N6 15M26N6 15M29N6
National Pipe Thread (NPT)
15,000
1/4 NPT (1034.20) 15M42N1 15M44N2 15M46N2 10M48N2 15M44N6 15M46N6 15M49N6 15M412N6 15M416N6 15M424N6
15,000
3/8 NPT (1034.20) 15M62N1 15M64N2 15M66N2 10M68N2 15M64N6 15M66N6 15M69N6 15M612N6 15M616N6
15,000
1/2 NPT (1034.20) 15M82N1 15M84N2 15M86N2 10M88N2 15M84N6 15M86N6 15M89N6 15M812N6 15M816N6
10,000
3/4 NPT (689.45) 10M124N2 10M126N2 10M128N2 10M124N6 10M126N6 10M129N6 10M1212N6 10M1216N6
10,000
1 NPT (689.45) 10M166N2 10M168N2 10M166N6 10M169N6 10M1612N6 10M1616N6
Note: * The maximum pressure rating for an adapter is determined by the connection component with the
All Parker Autoclave Engineers adapters are supplied complete with appropriate glands, collars, tube LOWEST pressure rating; that is, the two end connections and the tubing or pipe used, whichever is
nuts and sleeves unless specified without. LOWER.
CAUTION: See appropriate pressure section in reference to proper selection of tubing.
2 All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold.
Double Cone Plug Double Cone Plug Flat Bottom Gasket Flat Top Gasket Male NPT
(Medium Pressure shown) (SpeedBite shown) (Medium Pressure shown) (SpeedBite shown) (High Pressure shown)
FEMALE END
High Pressure National Pipe Thread (NPT)
1 1/4 5/16 3/8 9/16 9/16 1/8 1/4 3/8 1/2 3/4 1
F1000C43 F250C F312C150 F375C F562C F562C40 NPT NPT NPT NPT NPT NPT
43,000 60,000 150,000 60,000 60,000 40,000 15,000 15,000 15,000 15,000 10,000 10,000
(2964.69) (4136.85) (10342.14) (4136.85) (4136.85) (2757.90) (1034.20) (1034.20) (1034.20) (1034.20) (689.45) (689.45)
6M24C3 6M26C3 6M29C3 15M22C8 15M24C8 15M26C8 15M28C8
20M64K3 20M65K3 20M66K3 20M69K3 15MX62K8 15MX64K8 15MX66K8 15MX68K8 10MX612K8 10MX616K8
20M94K3 20M95K3 20M96K3 20M99K3 15MX92K8 15MX94K8 15MX96K8 15MX98K8 10MX912K8 10MX916K8
20M1216K3 20M124K3 20M125K3 20M126K3 20M129K3 20M129K40 15MX124K8 15MX126K8 15MX128K8 10MX1212K8 10MX1216K8
15M244K8 15M248K8
43M416B3 60M44B3 60M45B3 60M46B3 60M49B3 15M42B8 15M44B8 15M46B8 15M48B8 10M412B8 10M416B8
43M616B3 60M64B3 60M65B3 60M66B3 60M69B3 15M62B8 15M64B8 15M66B8 15M68B8 10M612B8 10M616B8
43M916B3 60M94B3 60M95B3 60M96B3 60M99B3 15M92B8 15M94B8 15M96B8 15M98B8 10M912B8 10M916B8
15M98G8
Parker Autoclave Engineers Male/Female Adapters are available in a one-piece design. They are identi- For prompt service, Parker Autoclave Engineers stocks select products.
cal to the two piece designs in length and can be ordered by adding the suffix - OP to the two piece Consult factory.
adapter part numbers listed.
All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold. 3
Adapters/Couplings - Male/Female Adapters
Speed Bite
Male End Dimension inches (mm) Male End Dimension inches (mm)
Female Catalog Female Catalog
Fits this Fits this
End Number A Hex B End Number A Hex B
Connection Connection
SW250 W125 6M42D1 0.63 (15.9) 1.08 (27.4) SW500 W125 4M82D1 0.94 (23.8) 1.22 (31.0)
SW250 SW250 SW500 SW250 4M84D2 0.94 (23.8) 1.34 (34.1)
SW250 SW375 6M46D2 0.75 (19.1) 1.64 (41.7) SW500 SW375 4M86D2 0.94 (23.8) 1.47 (37.3)
SW250 SW500 4M48D2 1.00 (25.4) 1.77 (44.9) SW500 SW500
SW250 SF250CX 6M44D6 0.63 (15.9) 1.52 (38.5) SW500 SF250CX 4M84D6 1.00 (25.4) 1.59 (40.5)
SW250 SF375CX 6M46D6 0.75 (19.1) 1.77 (44.9) SW500 SF375CX 4M86D6 1.00 (25.4) 1.59 (40.5)
SW250 SF562CX 6M49D6 1.00 (25.4) 1.89 (48.0) SW500 SF562CX 4M89D6 1.00 (25.4) 1.66 (42.2)
SW250 SF750CX 6M412D6 1.38 (35.1) 2.27 (57.7) SW500 SF750CX 4M812D6 1.38 (35.1) 2.09 (53.2)
SW250 SF1000CX SW500 SF1000CX 4M816D6 1.75 (44.5) 2.72 (69.0)
SW250 F1000C43 SW500 F1000C43
SW250 F250C 6M44D3 .75 (19.1) 1.27 (32.2) SW500 F250C 4M84D3 0.94 (23.8) 1.41 (35.7)
SW250 F312C150 SW500 F312C150
SW250 F375C 6M46D3 1.00 (25.4) 1.70 (43.3) SW500 F375C 4M86D3 1.00 (25.4) 1.59 (40.5)
SW250 F562C 6M49D3 1.38 (35.1) 1.77 (44.9) SW500 F562C 4M89D3 1.38 (35.1) 1.72 (43.7)
SW250 F562C40 SW500 F562C40
SW250 1/8 NPT 15M42D8 0.63 (15.9) 1.39 (35.3) SW500 1/8 NPT 10M82D8 1.00 (25.4) 1.34 (34.1)
SW250 1/4 NPT 15M44D8 0.75 (19.1) 1.64 (41.7) SW500 1/4 NPT 10M84D8 1.00 (25.4) 1.47 (37.3)
SW250 3/8 NPT 15M46D8 1.00 (25.4) 1.70 (43.3) SW500 3/8 NPT 10M86D8 1.00 (25.4) 1.72 (43.7)
SW250 1/2 NPT 15M48D8 1.18 (30.1) 1.95 (49.6) SW500 1/2 NPT 10M88D8 1.18 (30.1) 2.16 (54.7)
SW250 3/4 NPT 10M412D8 1.38 (35.1) 2.21 (56.0) SW500 3/4 NPT 10M812D8 1.38 (35.1) 2.22 (56.3)
SW250 1 NPT SW500 1 NPT 10M816D8 1.75 (44.5) 2.47 (62.7)
Maximum pressure rating is based on the lowest rating of any For prompt service, Parker Autoclaves Engineers stocks
component. Actual working pressure may be determined by select products. Consult factory.
tubing pressure rating, if lower.
A
Note: For pressure rating see selection chart. Hex
4 All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold.
Medium Pressure
Male End Dimension inches (mm) Male End Dimension inches (mm)
Female Catalog Female Catalog
Fits this Fits this
End Number A Hex B End Number A Hex B
Connection Connection
SF250CX W125 15MX42K1 0.63 (15.9) 1.34 (34.1) SF562CX W125 15MX92K1 0.81 (20.6) 1.75 (44.5)
SF250CX SW250 6MX44K2 0.63 (15.9) 1.59 (40.5) SF562CX SW250 6MX94K2 0.94 (23.8) 1.75 (44.5)
SF250CX SW375 6MX46K2 0.75 (19.1) 1.59 (40.5) SF562CX SW375 6MX96K2 0.94 (23.8) 1.75 (44.5)
SF250CX SW500 4MX48K2 1.00 (25.4) 1.00 (25.4) SF562CX SW500 4MX98K2 1.00 (25.4) 1.94 (49.2)
SF250CX SF250CX 20M44K6 0.63 (15.9) 1.47 (37.3) SF562CX SF250CX 20M94K6 0.94 (23.8) 1.34 (34.1)
SF250CX SF375CX 20M46K6 0.75 (19.1) 1.59 (40.5) SF562CX SF375CX 20M96K6 0.94 (23.8) 1.34 (59.5)
SF250CX SF562CX 20M49K6 1.00 (25.4) 1.97 (50.0) SF562CX SF562CX 20M99K6 1.00 (25.4) 2.00 (50.8)
SF250CX SF750CX 20M412K6 1.38 (35.1) 2.34 (59.5) SF562CX SF750CX 20M912K6 1.38 (35.1) 3.12 (79.3)
SF250CX SF1000CX 20M416K6 1.75 (44.5) 2.84 (72.2) SF562CX SF1000CX 20M916K6 1.75 (44.5) 3.75 (95.3)
SF250CX F1000C43 SF562CX F1000C43
SF250CX F250C 20M44K3 0.75 (19.1) 1.28 (32.5) SF562CX F250C 20M94K3 0.81 (20.6) 1.81 (46.0)
SF250CX F312C150 20M45K3 1.00 (25.4) 2.09 (53.2) SF562CX F312C150 20M95K3 1.00 (25.4) 2.50 (63.5)
SF250CX F375C 20M46K3 1.00 (25.4) 1.59 (40.5) SF562CX F375C 20M96K3 1.00 (25.4) 2.00 (50.8)
SF250CX F562C 20M49K3 1.38 (35.1) 1.97 (50.0) SF562CX F562C 20M99K3 1.38 (35.1) 2.12 (54.0)
SF250CX F562C40 SF562CX F562C40
SF250CX 1/8 NPT 15MX42K8 0.63 (15.9) 1.47(37.3) SF562CX 1/8 NPT 15MX92K8 0.94 (23.8) 1.75 (44.5)
SF250CX 1/4 NPT 15MX44K8 0.75 (19.1) 1.59 (40.5) SF562CX 1/4 NPT 15MX94K8 0.94 (23.8) 2.18 (55.5)
SF250CX 3/8 NPT 15MX46K8 1.00 (25.4) 1.66 (42.2) SF562CX 3/8 NPT 15MX96K8 0.94 (23.8) 2.18 (55.5)
SF250CX 1/2 NPT 15MX48K8 1.18 (30.1) 1.97 (50.0) SF562CX 1/2 NPT 15MX98K8 1.18 (30.1) 2.44 (61.9)
SF250CX 3/4 NPT 10MX412K8 1.38 (35.1) 2.09 (53.2) SF562CX 3/4 NPT 10MX912K8 1.50 (38.1) 2.50 (63.5)
SF250CX 1 NPT SF562CX 1 NPT 10MX916K8 1.75 (44.5) 3.00 (76.2)
Maximum pressure rating is based on the lowest rating of any For prompt service, Parker Autoclave Engineers stocks
component. Actual working pressure may be determined by select products. Consult factory.
tubing pressure rating, if lower.
All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold. 5
Male End Dimension inches (mm)
Female Catalog
Fits this
End Number A Hex B
Connection A
Hex
SF1000CX W125 6MX162K2 1.38 (35.1) 2.69 (68.3)
SF1000CX SW250 6MX164K2 1.38 (35.1) 2.63 (66.7)
SF1000CX SW375 6MX166K2 1.38 (35.1) 2.63 (66.7)
B
SF1000CX SW500 4MX168K2 1.18 (30.1) 2.69 (68.25)
SF1000CX SF250CX 20M164K6 1.38 (35.1) 2.63 (66.7) Adapter configurations may vary from outline shown
SF1000CX SF375CX 20M166K6 1.38 (35.1) 2.63 (66.7)
SF1000CX SF562CX 20M169K6 1.38 (35.1) 2.63 (66.7)
SF1000CX SF750CX 20M1612K6 1.50 (38.1) 2.12 (54.0) Male End Dimension inches (mm)
Female Catalog
SF1000CX SF1000CX Fits this
End Number A Hex B
SF1000CX F1000C43 Connection
SF1000CX F250C 20M164K3 1.38 (35.1) 2.18 (55.6)
SF1500CX SF250CX 15M244K6 1.88 (47.75) 3.31 (84.12)
SF1000CX F312C150
SF1500CX SF562CX 15M249K6 1.88 (47.75) 3.31 (84.12)
SF1000CX F375C 20M166K3 1.38 (35.1) 2.18 (55.6)
SF1500CX SF750CX 15M2412K6 1.88 (47.75) 3.81 (96.82)
SF1000CX F562C 20M169K3 1.50 (38.1) 2.44 (61.9)
SF1500CX SF1000CX 15M2416K6 1.88 (47.75) 4.06 (103.17)
SF1000CX F562C40
SF1500CX 1/4 NPT 15M244K8 1.75 (44.5) 3.56 (90.43)
SF1000CX 1/8 NPT
SF1500CX 1/2 NPT 15M248K8 1.75 (44.5) 3.56 (90.43)
SF1000CX 1/4 NPT 15MX164K8 1.50 (38.1) 3.18 (81.0)
SF1000CX 3/8 NPT 15MX166K8 1.75 (44.5) 3.18 (81.0)
SF1000CX 1/2 NPT 15MX168K8 1.75 (44.5) 3.18 (81.0)
SF1000CX 3/4 NPT 10MX1612K8 1.75 (44.5) 3.18 (81.0)
SF1000CX 1 NPT 10MX1616K8 1.75 (44.5) 3.18 (81.0)
High Pressure
Male End Dimension inches (mm) Male End Dimension inches (mm)
Female Catalog Female Catalog
Fits this Fits this
End Number A Hex B End Number A Hex B
Connection Connection
Maximum pressure rating is based on the lowest rating of any For prompt service, Parker Autoclave Engineers stocks
component. Actual working pressure may be determined by select products. Consult factory.
tubing pressure rating, if lower.
A
Note: For pressure rating see selection chart. Hex
6 All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold.
Male End Dimension inches (mm) Male End Female Dimension inches (mm)
Female Catalog Catalog
Fits this Fits this End
End Number A Hex B Number A Hex B
Connection Connection
Maximum pressure rating is based on the lowest rating of any For prompt service, Parker Autoclave Engineers stocks
component. Actual working pressure may be determined by select products. Consult factory.
tubing pressure rating, if lower.
All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold. 7
Flat Bottom
Male End Dimension inches (mm) Male End Dimension inches (mm)
Female Catalog Female Catalog
Fits this Fits this
End Number A Hex B End Number A Hex B
Connection Connection
F437FB W125 15M72E1 0.50 (12.7) 1.41 (35.8) F750FB W125 15M122E1 0.75 (19.1) 1.69 (42.8)
F437FB SW250 6M74E2 0.63 (15.9) 1.53 (38.9) F750FB SW250 6M124E2 0.81 (20.6) 2.06 (52.4)
F437FB SW375 6M76E2 0.75 (19.1) 1.91 (48.4) F750FB SW375 6M126E2 0.75 (19.1) 1.94 (49.2)
F437FB SW500 4M78E2 1.00 (25.4) 2.16 (54.8) F750FB SW500 4M128E2 1.00 (25.4) 2.18 (55.5)
F437FB SF250CX 15M74E6 0.63 (15.9) 1.53 (38.9) F750FB SF250CX 15M124E6 0.81 (20.6) 1.94 (49.2)
F437FB SF375CX 15M76E6 0.75 (19.1) 1.78 (45.2) F750FB SF375CX 15M126E6 0.81 (20.6) 2.06 (52.4)
F437FB SF562CX 15M79E6 1.00 (25.4) 1.91 (48.4) F750FB SF562CX 15M129E6 1.00 (25.4) 1.31 (33.3)
F437FB SF750CX F750FB SF750CX 15M1212E6 1.38 (35.1) 1.69 (42.8)
F437FB SF1000CX F750FB SF1000CX 15M1216E6 1.75 (44.5) 3.31 (84.1)
F437FB F1000C43 F750FB F1000C43
F437FB F250C 15M74E3 0.75 (19.1) 1.53 (38.9) F750FB F250C 15M124E3 1.00 (25.4) 1.94 (49.2)
F437FB F312C150 F750FB F312C150
F437FB F375C 15M76E3 1.00 (25.4) 1.78 (45.2) F750FB F375C 15M126E3 1.00 (25.4) 2.18 (55.5)
F437FB F562C 15M79E3 1.38 (35.1) 2.03 (51.6) F750FB F562C 15M129E3 1.38 (35.1) 2.31 (58.7)
F437FB F562C40 F750FB F562C40
F437FB 1/8 NPT 10M72E8 0.63 (15.9) 1.59 (40.4) F750FB 1/8 NPT 10M122E8 0.94 (23.8) 1.81 (46.0)
F437FB 1/4 NPT 10M74E8 0.75 (19.1) 1.78 (45.2) F750FB 1/4 NPT 10M124E8 1.00 (25.4) 2.31 (58.7)
F437FB 3/8 NPT 10M76E8 1.00 (25.4) 1.91 (48.4) F750FB 3/8 NPT 10M126E8 1.00 (25.4) 2.18 (55.5)
F437FB 1/2 NPT 10M78E8 1.18 (30.1) 2.16 (54.8) F750FB 1/2 NPT 10M128E8 1.18 (30.1) 2.69 (68.3)
F437FB 3/4 NPT F750FB 3/4 NPT 10M1212E8 1.38 (35.1) 2.69 (68.3)
F437FB 1 NPT F750FB 1 NPT 10M1216E8 1.88 (47.6) 3.18 (81.0)
Flat Top
F562FB W125 15M92E1 0.63 (15.9) 1.44 (36.5) F562FT W125 15M92R1 0.75 (19.1) 0.94 (23.9)
F562FB SW250 6M94E2 0.75 (19.1) 2.06 (52.4) F562FT SW250 6M94R2 0.75 (19.1) 1.50 (38.1)
F562FB SW375 6M96E2 0.75 (19.1) 2.25 (57.2) F562FT SW375 6M96R2 0.75 (19.1) 1.50 (38.1)
F562FB SW500 4M98E2 1.00 (25.4) 2.18 (55.5) F562FT SW500 4M98R2 1.00 (25.4) 1.63 (41.3)
F562FB SF250CX 15M94E6 0.63 (15.9) 1.81 (46.0) F562FT SF250CX 15M94R6 0.75 (19.1) 1.25 (31.8)
F562FB SF375CX 15M96E6 0.75 (19.1) 2.06 (52.4) F562FT SF375CX 15M96R6 0.75 (19.1) 1.50 (38.1)
F562FB SF562CX 15M99E6 1.00 (25.4) 1.18 (30.1) F562FT SF562CX 15M99R6 1.00 (25.4) 1.63 (41.3)
F562FB SF750CX 15M912E6 1.38 (35.1) 2.81 (71.4) F562FT SF750CX
F562FB SF1000CX F562FT SF1000CX
F562FB F1000C43 F562FT F1000C43
F562FB F250C 15M94E3 0.81 (20.6) 1.94 (49.2) F562FT F250C 15M94R3 0.75 (19.1) 1.25 (31.8)
F562FB F312C150 F562FT F312C150
F562FB F375C 15M96E3 1.00 (25.4) 2.44 (61.9) F562FT F375C 15M96R3 1.00 (25.4) 1.50 (38.1)
F562FB F562C F562FT F562C 15M99R3 1.38 (35.1) 1.75 (44.5)
F562FB F562C40 F562FT F562C40
F562FB 1/8 NPT 10M92E8 0.63 (15.9) 1.94 (49.2) F562FT 1/8 NPT 10M92R8 0.75 (19.1) 1.25 (31.8)
F562FB 1/4 NPT 10M94E8 0.75 (19.1) 2.18 (55.5) F562FT 1/4 NPT 10M94R8 0.75 (19.1) 1.44 (36.5)
F562FB 3/8 NPT 10M96E8 1.00 (25.4) 2.31 (58.7) F562FT 3/8 NPT 10M96R8 0.94 (23.8) 1.56 (39.7)
F562FB 1/2 NPT 10M98E8 1.18 (30.1) 1.63 (41.3) F562FT 1/2 NPT 10M98R8 1.18 (30.1) 2.00 (50.8)
F562FB 3/4 NPT 10M912E8 1.38 (35.1) 2.06 (52.4) F562FT 3/4 NPT
F562FB 1 NPT 10M916E8 1.88 (47.6) 2.25 (57.2) F562FT 1 NPT
8 All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold.
National Pipe Thread (NPT)
Male End Dimension inches (mm) Male End Dimension inches (mm)
Female Catalog Female Catalog
Fits this Fits this
End Number A Hex B End Number A Hex B
Connection Connection
1/8 NPT W125 15M22N1 0.50 (12.7) 1.00 (25.4) 3/8 NPT W125 15M62N1 0.75 (19.1) 1.13 (28.6)
1/8 NPT SW250 15M24N2 0.63 (15.9) 1.25 (31.8) 3/8 NPT SW250 15M64N2 0.75 (19.1) 1.38 (35.1)
1/8 NPT SW375 15M26N2 0.75 (19.1) 1.44 (36.5) 3/8 NPT SW375 15M66N2 0.75 (19.1) 1.50 (38.1)
1/8 NPT SW500 10M28N2 1.00 (25.4) 1.50 (38.1) 3/8 NPT SW500 10M68N2 1.00 (25.4) 1.75 (44.5)
1/8 NPT SF250CX 15M24N6 0.63 (15.9) 1.81 (46.0) 3/8 NPT SF250CX 15M64N6 0.75 (19.1) 1.38 (35.1)
1/8 NPT SF375CX 15M26N6 0.75 (19.1) 1.38 (35.1) 3/8 NPT SF375CX 15M66N6 0.75 (19.1) 1.50 (38.1)
1/8 NPT SF562CX 15M29N6 1.00 (25.4) 1.75 (44.5) 3/8 NPT SF562CX 15M69N6 1.00 (25.4) 1.75 (44.5)
1/8 NPT SF750CX 3/8 NPT SF750CX 15M612N6 1.38 (35.1) 2.00 (50.8)
1/8 NPT SF1000CX 3/8 NPT SF1000CX 15M616N6 1.75 (44.5) 2.88 (73.0)
1/8 NPT F1000C43 3/8 NPT F1000C43
1/8 NPT F250C 15M24N3 0.75 (19.1) 1.25 (31.8) 3/8 NPT F250C 15M64N3 0.75 (19.1) 1.38 (35.1)
1/8 NPT F312C150 3/8 NPT F312C150
1/8 NPT F375C 15M26N3 1.00 (25.4) 1.50 (38.1) 3/8 NPT F375C 15M66N3 1.00 (25.4) 1.63 (41.3)
1/8 NPT F562C 15M29N3 1.38 (35.1) 1.63 (41.3) 3/8 NPT F562C 15M69N3 1.38 (35.1) 1.75 (44.5)
1/8 NPT F562C40 3/8 NPT F562C40 15M69N40 1.38 (35.1) 1.75 (44.5)
1/8 NPT 1/8 NPT 3/8 NPT 1/8 NPT
1/8 NPT 1/4 NPT 15M24N8 0.75 (19.1) 1.38 (35.1) 3/8 NPT 1/4 NPT 15M64N8 0.75 (19.1) 1.63 (41.3)
1/8 NPT 3/8 NPT 3/8 NPT 3/8 NPT
1/8 NPT 1/2 NPT 3/8 NPT 1/2 NPT 15M68N8 1.18 (30.1) 2.25 (57.2)
1/8 NPT 3/4 NPT 3/8 NPT 3/4 NPT
1/8 NPT 1 NPT 3/8 NPT 1 NPT
1/4 NPT W125 15M42N1 0.63 (15.9) 1.13 (28.6) 1/2 NPT W125 15M82N1 1.00 (25.4) 2.50 (63.5)
1/4 NPT SW250 15M44N2 0.63 (15.9) 1.38 (35.1) 1/2 NPT SW250 15M84N2 1.00 (25.4) 1.63 (41.3)
1/4 NPT SW375 15M46N2 0.75 (19.1) 1.50 (38.1) 1/2 NPT SW375 15M86N2 1.00 (25.4) 1.63 (41.3)
1/4 NPT SW500 10M48N2 1.00 (25.4) 1.75 (44.5) 1/2 NPT SW500 10M88N2 1.00 (25.4) 1.88 (47.6)
1/4 NPT SF250CX 15M44N6 0.63 (15.9) 1.38 (35.1) 1/2 NPT SF250CX 15M84N6 1.00 (25.4) 1.38 (35.1)
1/4 NPT SF375CX 15M46N6 0.75 (19.1) 1.56 (39.7) 1/2 NPT SF375CX 15M86N6 1.00 (25.4) 1.63 (41.3)
1/4 NPT SF562CX 15M49N6 1.00 (25.4) 1.75 (44.5) 1/2 NPT SF562CX 15M89N6 1.00 (25.4) 1.94 (49.2)
1/4 NPT SF750CX 15M412N6 1.38 (35.1) 2.25 (57.2) 1/2 NPT SF750CX 15M812N6 1.38 (35.1) 2.18 (55.5)
1/4 NPT SF1000CX 15M416N6 1.75 (44.5) 2.88 (73.0) 1/2 NPT SF1000CX 15M816N6 1.75 (44.5) 2.81 (71.4)
1/4 NPT SF1500CX 15M424N6 2.25 (57.15) 3.48 (88.39) 1/2 NPT F1000C43
1/4 NPT F1000C43 1/2 NPT F250C 15M84N3 1.00 (25.4) 1.50 (38.1)
1/4 NPT F250C 15M44N3 0.75 (19.1) 1.38 (35.1) 1/2 NPT F312C150
1/4 NPT F312C150 15M45N3 1.00 (25.4) 2.50 (63.5) 1/2 NPT F375C 15M86N3 1.00 (25.4) 1.75 (44.5)
1/4 NPT F375C 15M46N3 1.00 (25.4) 1.63 (41.3) 1/2 NPT F562C 15M89N3 1.38 (35.1) 1.88 (47.6)
1/4 NPT F562C 15M49N3 1.38 (35.1) 1.75 (44.5) 1/2 NPT F562C40 15M89N40 1.38 (35.1) 1.75 (44.5)
1/4 NPT F562C40 1/2 NPT 1/8 NPT
1/4 NPT 1/8 NPT 15M42N8 0.63 (15.9) 1.38 (35.1) 1/2 NPT 1/4 NPT 15M84N8 1.00 (25.4) 1.75 (44.5)
1/4 NPT 1/4 NPT 1/2 NPT 3/8 NPT 15M86N8 1.00 (25.4) 1.81 (71.4)
1/4 NPT 3/8 NPT 15M46N8 1.00 (25.4) 1.75 (44.5) 1/2 NPT 1/2 NPT
1/4 NPT 1/2 NPT 15M48N8 1.18 (30.1) 2.25 (57.2) 1/2 NPT 3/4 NPT 10M812N8 1.38 (35.1) 2.25 (57.2)
1/4 NPT 3/4 NPT 1/2 NPT 1 NPT
1/4 NPT 1 NPT
*Maximum pressure rating is based on the lowest rating of any For prompt service, Parker Autoclave Engineers stocks
component. Actual working pressure may be determined by select products. Consult factory.
tubing pressure rating, if lower.
All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold. 9
National Pipe Thread (NPT)
Male End Dimension inches (mm) Male End Dimension inches (mm)
Female Catalog Female Catalog
Fits this Fits this
End Number A Hex B End Number A Hex B
Connection Connection
Maximum pressure rating is based on the lowest rating of any For prompt service, Parker Autoclave Engineers stocks
component. Actual working pressure may be determined by select products. Consult factory.
tubing pressure rating, if lower.
10 All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold.
Adapters/Couplings - Couplings
How to use the Ordering Chart below: Note: Special material couplings may be supplied with four flats in place of
1. Locate A connection in the vertical column. standard hex.
A B Connection
Connection SpeedBite Medium Pressure High Pressure
Tube 1/8 1/4 3/8 1/2** 1/4 3/8 9/16 3/4 1 1 1/4 3/8 9/16 9/16 5/16
Outside Connector Pressure W SW SW SW SF SF SF SF SF F F F F F F
in (mm) Type psi 125 250 375 500 250 375 562 750 1000 1000 250 375 562 562 312
(bar)* CX CX CX CX CX C43 C C C C40 C150
1/8 W125 15,000 15F 6F 6F 4F 15F 15F 15F 15F 15F 15F 15F
(3.18) (1034) 2211 2412 2612 2812 2416 2616 2916 21616 2413 2613 2913
(6.35) (1034) 4422 4622 4822 4426 4626 4926 4423 4623 4923
1/4 SF250 20,000 20FX 20F 20F 20F 20F 20F 20F 20F 20F 20F
(6.35) CX (1379) 4466 4666 4966 41266 41666 41663 4463 4663 4963 4563
3/8 SF375 20,000 20FX 20F 20F 20F 20F 20F 20F 20F 20F
Medium Pressure
(9.52) CX (1379) 6666 6966 61266 61666 61663 6463 6663 6963 6563
9/16 SF562 20,000 20FX 20F 20F 20F 20F 20F 20F
(14.27) CX (1379) 9966 91266 91666 9463 9663 9963 9563
1/8 NPT 15,000 15F 15F 15F 10F 15F 15F 15F 15F 15F 15F 15F 15F
(3.18) (1034) 2281 2482 2682 2882 2486 2686 2986 21286 2483 2683 2983 2583
National Pipe Thread (NPT)
1/4 NPT 15,000 15F 15F 15F 10F 15F 15F 15F 15F 15F 15F 15F 15F 15F
(6.35) (1034) 4281 4482 4682 4882 4486 4686 4986 41286 41686 4483 4683 4983 4583
3/8 NPT 15,000 15F 15F 15F 10F 15F 15F 15F 15F 15F 15F 15F 15F 15F
(9.52) (1034) 6281 6482 6682 6882 6486 6686 6986 61286 61686 6483 6683 6983 6583
1/2 NPT 15,000 15F 15F 15F 10F 15F 15F 15F 15F 15F 15F 15F 15F 15F
(12.70) (1034) 8281 8482 8682 8882 8486 8686 8986 81286 81686 8483 8683 8983 8583
*Maximum pressure rating is based on the lowest rating of any component. All dimensions for reference only and subject to change.
Actual working pressure may be determined by tubing pressure rating, if lower. For prompt service, Parker Autoclave Engineers stocks select products. Consult your local
**1/2 low pressure rated to 10,000 psi. representative.CAUTION: See appropriate pressure section in reference to proper selection of tubing.
All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold. 11
Coupling Dimensions - Speedbite
Connection Connection Catalog Dimension inches (mm) Connection Connection Catalog Dimension inches (mm)
A B Number A Hex B A B Number A Hex B
W125 W125 15F2211 0.50 (12.7) 1.25 (31.7) SW375 SW375 6F6622 0.75 (19.1) 1.75 (44.5)
W125 SW250 6F2412 0.63 (15.9) 1.44 (36.6) SW375 SW500 4F6822 1.00 (25.4) 1.88 (47.8)
W125 SW375 6F2612 0.75 (19.1) 1.50 (38.1) SW375 SF250CX 6F6426 0.75 (19.1) 0.88 (22.2)
W125 SW500 4F2812 1.00 (25.4) 1.63 (41.4) SW375 SF375CX 6F6626 0.75 (19.1) 1.75 (44.5)
W125 SF250CX 15F2416 0.63 (15.9) 1.38 (35.1) SW375 SF562CX 6F6926 1.00 (25.4) 2.00 (50.8)
W125 SF375CX 15F2616 0.75 (19.1) 1.50 (38.1) SW375 SF750CX 6F61226 1.38 (35.1) 2.25 (57.2)
W125 SF562CX 15F2916 1.00 (25.4) 1.75 (44.5) SW375 SF1000CX 6F61626 1.75 (44.5) 3.00 (76.2)
W125 SF1000CX 15F21616 1.75 (44.5) 2.75 (69.9) SW375 F250C 6F6423 0.75 (19.1) 1.63 (41.4)
W125 F250C 15F2413 0.75 (19.1) 1.25 (31.7) SW375 F375C 6F6623 1.00 (25.4) 1.81 (46.0)
W125 F375C 15F2613 1.00 (25.4) 1.50 (38.1) SW375 F562C 6F6923 1.38 (35.1) 2.00 (50.8)
W125 F562C 15F2913 1.38 (35.1) 1.75 (44.5)
SW500 SW500 4F8822 1.00 (25.4) 2.00 (50.8)
SW250 SW250 6F4422 0.63 (15.9) 1.63 (41.4) SW500 SF250CX 4F8426 1.00 (25.4) 1.63 (41.4)
SW250 SW375 6F4622 0.75 (19.1) 1.69 (42.9) SW500 SF375CX 4F8626 1.00 (25.4) 1.88 (47.8)
SW250 SW500 4F4822 1.00 (25.4) 1.88 (47.8) SW500 SF562CX 4F8926 1.00 (25.4) 2.00 (50.8)
SW250 SF250CX 6F4426 0.63 (15.9) 1.63 (41.4) SW500 SF750CX 4F81226 1.38 (35.1) 2.25 (57.2)
SW250 SF375CX 6F4626 0.75 (19.1) 1.75 (44.5) SW500 SF1000CX 4F81626 1.75 (44.5) 3.00 (76.2)
SW250 SF562CX 6F4926 1.00 (25.4) 2.00 (50.8) SW500 F250C 4F8423 1.00 (25.4) 1.69 (42.9)
SW250 F250C 6F4423 0.75 (19.1) 1.50 (38.1) SW500 F375C 4F8623 1.00 (25.4) 1.88 (47.8)
SW250 F375C 6F4623 1.00 (25.4) 1.69 (42.9) SW500 F562C 4F8923 1.38 (35.1) 2.06 (52.3)
SW250 F562C 6F4923 1.38 (35.1) 2.06 (52.3)
Connection Connection Catalog Dimension inches (mm) Connection Connection Catalog Dimension inches (mm)
A B Number A Hex B A B Number A Hex B
SF250CX SF250CX 20FX4466 0.63 (15.9) 1.63 (41.4) SF750CX SF750CX 20FX12 1.38 (35.1) 2.50 (63.5)
SF250CX SF375CX 20F4666 0.75 (19.1) 1.75 (44.5) SF750CX SF1000CX 20F121666 1.75 (44.5) 3.00 (76.2)
SF250CX SF562CX 20F4966 1.00 (25.4) 2.00 (50.8) SF750CX F250C 20F12463 1.38 (35.1) 2.50 (63.5)
SF250CX SF750CX 20F41266 1.38 (35.1) 2.25 (57.2) SF750CX F375C 20F12663 1.38 (35.1) 2.38 (60.33)
SF250CX SF1000CX 20F41666 1.75 (44.5) 2.75 (69.9) SF750CX F562C 20F12963 1.38 (35.1) 2.75 (69.9)
SF250CX F250C 20F4463 0.75 (19.1) 1.38 (35.1) SF750CX F312C150 20F12563 1.38 (35.1) 2.75 (69.9)
SF250CX F375C 20F4663 1.00 (25.4) 1.63 (41.4)
SF250CX F562C 20F4963 1.38 (35.1) 1.88 (47.8) SF1000CX SF1000CX 20FX16 1.75 (44.5) 3.50 (88.9)
SF250CX F312C150 20F4563 1.00 (25.4) 2.13 (54.1) SF1000CX F250C 20F16463 1.75 (44.5) 2.75 (69.9)
SF250CX F1000C43 43F41663 1.75 (44.5) 2.75 (69.9) SF1000CX F375C 20F16663 1.75 (44.5) 2.88 (73.0)
SF1000CX F562C 20F16963 1.75 (44.5) 3.25 (82.6)
SF375CX SF375CX 20FX6666 0.75 (19.1) 1.75 (44.5) SF1000CX F312C150 20F16563 1.75 (44.5) 3.25 (82.6)
SF375CX SF562CX 20F6966 1.00 (25.4) 2.00 (50.8)
SF375CX SF750CX 20F61266 1.38 (35.1) 2.25 (57.2)
SF375CX SF1000CX 20F61666 1.75 (44.5) 2.88 (73.0)
SF375CX F250C 20F6463 0.75 (19.1) 1.63 (41.4)
SF375CX F375C 20F6663 1.00 (25.4) 2.00 (50.8)
SF375CX F562C 20F6963 1.38 (35.1) 2.00 (50.8) A
SF375CX F312C150C 20F6563 1.00 (25.4) 2.25 (57.2) HEX
SF375CX F1000C43 43F61663 1.75 (44.5) 2.88 (73.0)
12 All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold.
Coupling Dimensions - High Pressure
Connection Connection Catalog Dimension inches (mm) Connection Connection Catalog Dimension inches (mm)
A B Number A Hex B A B Number A Hex B
1/8 NPT W125 15F2281 0.63 (15.9) 1.38 (35.1) 1/4 NPT W125 15F4281 0.75 (19.1) 1.50 (38.1)
1/8 NPT SW250 15F2482 0.63 (15.9) 1.50 (38.1) 1/4 NPT SW250 15F4482 0.75 (19.1) 1.63 (41.4)
1/8 NPT SW375 15F2682 0.75 (19.1) 1.63 (41.4) 1/4 NPT SW375 15F4682 0.75 (19.1) 1.75 (44.5)
1/8 NPT SW500 10F2882 1.00 (25.4) 1.50 (38.1) 1/4 NPT SW500 10F4882 1.00 (25.4) 2.00 (50.8)
1/8 NPT SF250CX 15F2486 0.63 (15.9) 1.38 (35.1) 1/4 NPT SF250CX 15F4486 0.75 (19.1) 1.63 (41.4)
1/8 NPT SF375CX 15F2686 0.75 (19.1) 1.50 (38.1) 1/4 NPT SF375CX 15F4686 0.75 (19.1) 1.75 (44.5)
1/8 NPT SF562CX 15F2986 1.00 (25.4) 1.63 (41.4) 1/4 NPT SF562CX 15F4986 1.00 (25.4) 2.00 (50.8)
1/8 NPT SF750CX 15F21286 1.38 (35.1) 1.75 (44.5) 1/4 NPT SF750CX 15F41286 1.38 (35.1) 1.75 (44.5)
1/8 NPT F250C 15F2483 0.75 (19.1) 1.38 (35.1) 1/4 NPT SF1000CX 15F41686 1.38 (35.1) 2.38 (60.33)
1/8 NPT F375C 15F2683 1.00 (25.4) 1.63 (41.4) 1/4 NPT F250C 15F4483 0.75 (19.1) 1.63 (41.4)
1/8 NPT F562C 15F2983 1.38 (35.1) 1.82 (46.2) 1/4 NPT F375C 15F4683 1.00 (25.4) 1.88 (47.8)
1/8 NPT F312C150 15F2583 1.00 (25.4) 2.13 (54.1) 1/4 NPT F562C 15F4983 1.38 (35.1) 2.00 (50.8)
1/4 NPT F312C150 15F4583 1.00 (25.4) 2.50 (63.5)
Maximum pressure rating is based on the lowest rating of any component.
Actual working pressure may be determined by tubing pressure rating, if lower.
Note: For pressure rating see selection chart.
A
HEX
All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold. 13
Coupling Dimensions - National Pipe Thread (NPT) - cont
Connection Connection Catalog Dimension inches (mm) Connection Connection Catalog Dimension inches (mm)
A B Number A Hex B A B Number A Hex B
3/8 NPT W125 15F6281 1.00 (25.4) 1.63 (41.1) 3/4 NPT SW500 10F12882 1.38 (35.1) 2.50 (63.5)
3/8 NPT SW250 15F6482 1.00 (25.4) 1.75 (44.5) 3/4 NPT SF375CX 10F12686 1.38 (35.1) 2.25 (57.2)
3/8 NPT SW375 15F6682 1.00 (25.4) 1.88 (47.8) 3/4 NPT SF562CX 10F12986 1.38 (35.1) 2.25 (57.2)
3/8 NPT SW500 10F6882 1.00 (25.4) 2.00 (50.8) 3/4 NPT SF750CX 10F121286 1.50 (38.1) 2.63 (66.7)
3/8 NPT SF250CX 15F6486 0.94 (23.9) 1.63 (41.4) 3/4 NPT SF1000CX 10F121686 1.75 (44.5) 3.00 (76.2)
3/8 NPT SF375CX 15F6686 0.94 (23.9) 1.82 (46.2) 3/4 NPT F562C 10F12983 1.38 (35.1) 2.38 (60.33)
3/8 NPT SF562CX 15F6986 1.00 (25.4) 2.00 (50.8)
3/8 NPT SF750CX 15F61286 1.38 (35.1) 2.38 (60.33) 1 NPT SF562CX 10F16986 1.75 (44.5) 2.63 (66.7)
3/8 NPT SF1000CX 15F61686 1.75 (44.5) 2.50 (63.5) 1 NPT SF1000CX 10F161686 1.75 (44.5) 2.88 (73.0)
3/8 NPT F250C 15F6483 1.00 (25.4) 1.63 (41.4) 1 NPT F250C 10F16483 1.88 (47.8) 2.38 (60.33)
3/8 NPT F375C 15F6683 1.00 (25.4) 1.88 (47.8) 1 NPT F562C 10F16983 1.75 (44.5) 2.50 (63.5)
3/8 NPT F562C 15F6983 1.38 (35.1) 2.00 (50.8)
3/8 NPT F312C150 15F6583 1.00 (25.4) 2.25 (57.2
14 All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold.
Adapters/Couplings - Male/Male Adapters
Ordering Procedure
20 MA M6 H9
Pressure Male Available End Connections
(X 1000 psi) Adapter
L2 - 1/8 Low Pressure M4 - 1/4 Medium Pressure H4 - 1/4 High Pressure P4 - 1/4 NPT * RH9 - 9/16 -18 Reverse High
L4 - 1/4 Low Pressure M6 - 3/8 Medium Pressure H5 - 5/16 High Pressure P6 - 3/8 NPT RH12 - 3/4 -16 Reverse High
L6 - 3/8 Low Pressure M9 - 9/16 Medium Pressure H6 - 3/8 High Pressure P8 - 1/2 NPT RH14 - 7/8 -14 Reverse High
L8 - 1/2 Low Pressure M12 - 3/4 Medium Pressure H9 - 9/16 High Pressure P12 - 3/4 NPT RH16 - 1 -12 Reverse High
M16 - 1 Medium Pressure P16 - 1 NPT RH21 - 1-5/16 -12 Reverse High
Note: Special material one piece adapters may be supplied with four flats in place of standard hex.
*RH9 & RH14 - 40,000 psi (2758 bar), RH12 - 30,000 psi (2068 bar), RH16 - 26,000 psi (1793 bar), RH21 - 20,000 psi (1379 bar).
All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold. 15
Low-Pressure to Low-Pressure Adapters
Catalog Connection Connection Dimension inches (mm)
Number L/P L/P A Hex B
16 All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold.
High-Pressure to High-Pressure Adapters
All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold. 17
High-Pressure to NPT Adapters
18 All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold.
High-Pressure to Reverse High-Pressure Adapters
All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold. 19
QSS Male/Female Adapters
Male /female adapters are designed to adapt a female connec- Materials
tion to another size and/or type of connection without the need All Parker Autoclave Engineers adapters are precision ma-
for additional couplings. In selecting an adapter involving two chined from cold-worked Type 316 stainless steel.
different sized connections, the larger connection should be
on the male end where it is possible to maximize the mechani-
cal strength of the adapter.
FEMALE END
Quick Set Medium Pressure
Connection
Size and Type 1/4 3/8 9/16 3/4 1/4 3/8 9/16 3/4 1
QS250 QS375 QS562 QS750 SF250CX SF375CX SF562CX SF750CX SF1000CX
Fits this Pressure 15,000 15,000 15,000 15,000 20,000 20,000 20,000 20,000 20,000
Female Rating (1034.20) (1034.20) (1034.20) (1034.20) (1378.93) (1378.93) (1378.93) (1378.93) (1378.93)
Connection PSI (bar)*
15,000
1/4 QS250 (1034.20) 15M46QQ 15M49QQ 15M412QQ 15M44Q6 15M46Q6 15M49Q6 15M412Q6 15M416Q6
15,000
Quick Set
3/8 QS375 (1034.20) 15M64QQ 15M69QQ 15M612QQ 15M64Q6 15M66Q6 15M69Q6 15M612Q6 15M616Q6
15,000
9/16 QS562 (1034.20) 15M94QQ 15M94QQ 15M912QQ 15M94Q6 15M96Q6 15M99Q6 15M912Q6 15M916Q6
15,000
3/4 QS750 (1034.20) 15M124QQ 15M126QQ 15M129QQ 15M124Q6 15M126Q6 15M129Q6 15M1212Q6 15M1216Q6
20,000
1/4 SF250CX (1378.93) 15M44KQ 15M46KQ 15M49KQ 15M412KQ
Medium Pressure
20,000
MALE END
(1034.20)
15,000
3/8 NPT (1034.20) 15M64NQ 15M66NQ 15M69NQ 15M612NQ
15,000
1/2 NPT (689.45) 15M84NQ 15M86NQ 15M89NQ 15M812NQ
10,000
3/4 NPT (689.45) 10M124NQ 10M126NQ 10M129NQ 10M1212NQ
10,000
1 NPT (689.45) 10M164NQ 10M166NQ 10M169NQ 10M1612NQ
Note:
All Parker Autoclave Engineers adapters are supplied complete with appropriate gland nuts and sleeves
unless specified without. NOTE: NPT (Pipe) connections
* The maximum pressure rating for an adapter is determined by the connection component with the
LOWEST pressure rating; that is, the two end connections and the tubing or pipe used, whichever is
NPT threads must be sealed using a high quality PTFE tape and/or
LOWER. PTFE paste product. Refer to thread sealant manufacturers instructions
CAUTION: See appropriate pressure section in reference to proper selection of tubing. on how to apply thread sealant.
Sealing performance may vary based on many factors such as pressure,
temperature, media, thread quality, thread material, proper thread
engagement and proper use of thread sealant.
Customer should limit the number of times an NPT fitting is assembled
and disassembled because thread deformation during assembly will
result in deteriorating seal quality over time. When using only PTFE
tape, consider using thread lubrication to prevent galling of mating parts.
20
Quick Set Female Quick Set Female Quick Set Female Quick Set Female
to to to to
Quick Set Male Medium Pressure Male High Pressure Male National Pipe Male
FEMALE END
High Pressure National Pipe Thread (NPT)
1/4 3/8 9/16 1/4 3/8 1/2 3/4 1
F250C F375C F562C NPT NPT NPT NPT NPT
60,000 60,000 150,000 15,000 15,000 15,000 10,000 10,000
(4136.85) (4136.85) (10342.14) (1034.20) (1034.20) (1034.20) (689.45) (689.45)
AE Male/Female Adapters are available in a one-piece design. They are identical to the two piece designs in
length and can be ordered by adding the suffix - OP to the two piece adapter part numbers listed.
For prompt service, Parker Autoclave Engineers stocks select products. Consult factory.factory.
21
QS Series
Male End Dimension inches (mm) Male End Dimension inches (mm)
Female Catalog Female Catalog
Fits this Fits this
End Number A Hex B End Number A Hex B
Connection Connection
QS375 QS250 15M64QQ 0.75 (19.1) 1.53 (38.9) QS750 QS250 15M124QQ
QS375 QS375 QS750 QS375 15M126QQ 1.50 (38.1) 2.53 (64.1)
QS375 QS562 15M69QQ QS750 QS562 15M129QQ 1.50 (38.1) 2.53 (64.1)
QS375 QS750 15M612QQ 1.50 (38.1) 2.78 (70.6) QS750 QS750
QS375 SF250CX 15M64Q6 QS750 SF250CX 15M124Q6
QS375 SF375CX 15M66Q6 0.75 (19.1) 1.66 (42.2) QS750 SF375CX 15M126Q6
QS375 SF562CX 15M69Q6 1.00 (25.4) 1.78 (45.2) QS750 SF562CX 15M129Q6
QS375 SF750CX 15M612Q6 QS750 SF750CX 15M1212Q6
QS375 SF1000CX 15M616Q6 QS750 SF1000CX 15M1216Q6
QS375 F250C 15M64Q3 QS750 F250C 15M124Q3
QS375 F375C 15M66Q3 QS750 F375C 15M126Q3
QS375 F562C 15M69Q3 QS750 F562C 15M129Q3
QS375 1/4 NPT 15M64Q8 0.75 (19.1) 1.66 (42.2) QS750 1/4 NPT 15M124Q8
QS375 3/8 NPT 15M66Q8 1.00 (25.4) 1.78 (45.3) QS750 3/8 NPT 15M126Q8
QS375 1/2 NPT 15M68Q8 1.19 (30.1) 2.16 (54.8) QS750 1/2 NPT 15M128Q8 1.50 (38.1) 2.78 (70.5)
QS375 3/4 NPT 10M612Q8 QS750 3/4 NPT 10M1212Q8
QS375 1 NPT 10M616Q8 QS750 1 NPT 10M1216Q8
For prompt service, Parker Autoclave Engineers stocks select products. Consult factory. Maximum pressure rating is based on the lowest rating of any component.
Actual working pressure may be determined by tubing pressure rating, if lower.
Note: For pressure rating see selection chart.
All Dimensions for reference only and subject to change.
A A
HEX HEX
B B
22
QS Series
Male End Dimension inches (mm) Male End Dimension inches (mm)
Female Catalog Female Catalog
Fits this Fits this
End Number A Hex B End Number A Hex B
Connection Connection
SF250CX QS250 15M44KQ 0.75 (19.1) 1.68 (42.7) F250C QS250 15M44BQ 0.75 (19.1) 1.31 (33.3)
SF250CX QS375 15M46KQ 0.81 (20.6) 1.68 (42.7) F250C QS375 15M46BQ 0.81 (20.6) 1.56 (39.7)
SF250CX QS562 15M49KQ 1.19 (30.1) 2.22 (56.4) F250C QS562 15M49BQ
SF250CX QS750 15M412KQ F250C QS750 15M412BQ
SF375CX QS250 15M64KQ 0.75 (19.1) 1.63 (41.4) F375C QS250 15M64BQ
SF375CX QS375 15M66KQ 0.81 (20.6) 1.81 (46.1) F375C QS375 15M66BQ 0.81 (20.6) 1.69 (42.9)
SF375CX QS562 15M69KQ F375C QS562 15M69BQ
SF375CX QS750 15M612KQ 1.50 (38.1) 3.00 (76.20) F375C QS750 15M612BQ
SF562CX QS250 15M94KQ 0.94 (23.8) 1.75 (44.5) F562C QS250 15M94BQ 1.19 (30.1) 1.81(46.1)
SF562CX QS375 15M96KQ 0.94 (23.8) 1.75 (44.5) F562C QS375 15M96BQ 1.19 (30.1) 1.69 (42.9)
SF562CX QS562 15M99KQ 1.38 (34.9) 2.50 (63.5) F562C QS562 15M99BQ 1.38 (34.9) 2.32 (58.8)
SF562CX QS750 15M912KQ 1.50 (38.1) 3.25 (82.6) F562C QS750 15M912BQ 1.50 (38.1) 3.06 (77.7)
MP to QSS HP to QSS
A
HEX A
HEX
B
B
23
QS Series
NPT to QSS
A
HEX
24
QSS Male/Male Adapters
Parker Autoclave Engineers standard male-to-male one piece adapters are
available in multiple configurations. Standard male-to-male adapters are
machined from cold worked stainless steel.Contact your local Sales
Representative for optional information. The following tables list our
standard adapters with dimensions.
Ordering Procedure
15 MA Q4 H9
Pressure Male Available End Connections
(X 1000 psi) Adapter
Q4 - 1/4 QS Series M4 - 1/4 Medium Pressure H4 - 1/4 High Pressure P4 - 1/4 NPT * RH9 - 9/16 -18 Reverse High
Q6 - 3/8 QS Series M6 - 3/8 Medium Pressure H5 - 5/16 High Pressure P6 - 3/8 NPT RH12 - 3/4 -16 Reverse High
Q9 - 9/16 QS Series M9 - 9/16 Medium Pressure H6 - 3/8 High Pressure P8 - 1/2 NPT RH14 - 7/8 -14 Reverse High
Q12 - 3/4 QS Series M12 - 3/4 Medium Pressure H9 - 9/16 High Pressure P12 - 3/4 NPT RH16 - 1 -12 Reverse High
M16 - 1 Medium Pressure P16 - 1 NPT RH21 - 1-5/16 -12 Reverse High
*RH9 & RH14 - 40,000 psi (2758 bar), RH12 - 30,000 psi (2068 bar), RH16 - 26,000 psi (1793 bar), RH21 - 20,000 psi (1379 bar).
25
QS Series to Reverse High-Pressure Adapters
26
Adapters/Couplings - Male/Male JIC Adapters
Ordering Procedure
Typical catalog number: 20 MA M4 J4
20 MA M4 J4
Pressure Male Available End Connections
(X 1000 psi) Adapter
*J4 - 1/4 JIC L4 - 1/4 Low Pressure M4 - 1/4 Medium Pressure H4 - 1/4 High Pressure P4 - 1/4 NPT
J6 - 3/8 JIC L6 - 3/8 Low Pressure M6 - 3/8 Medium Pressure H6 - 3/8 High Pressure P6 - 3/8 NPT
J8 - 1/2 JIC L8 - 1/2 Low Pressure M9 - 9/16 Medium Pressure H9 - 9/16 High Pressure P8 - 1/2 NPT
J10 - 5/8 JIC M12 - 3/4 Medium Pressure
J12 - 3/4 JIC M16 - 1 Medium Pressure
J16 - 1 JIC
Note: Special material one piece adapters may be supplied with four flats in place of standard hex. Thread Sizes
*J4, J6, J8 & J10 - 20,000 psi (1380 bar), J12 & J16 - 15,000 psi (1034 bar) J4 - 7/16-20
J6 - 9/16-18
J8 - 3/4-16
J10 - 7/8-14
J12 - 1-1/16-12
J16 - 1-5/16-12
All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold. 27
Low-Pressure to JIC Adapters
28 All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold.
JIC to JIC Adapters
15MAP8J8 1/2 1/2 1.00 (25.4) 2.13 (54.0) Note: For pressure rating see ordering procedure.
15MAP8J12 1/2 3/4 1.38 (34.9) 2.44 (61.9)
All Dimensions for reference only and are subject to change.
For prompt service, Parker Autoclave Engineers stocks select products. Consult factory.
All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold. 29
Adapters/Couplings - Male/Female JIC Adapters
FEMALE END
JIC Medium Pressure
Connection
Size and Type 1/4 3/8 1/2 5/8 3/4 1 1/4 3/8 9/16
JIC4 JIC6 JIC8 JIC10 JIC12 JIC16 SF250CX SF375CX SF562CX
Fits this Pressure 20,000 20,000 20,000 20,000 15,000 15,000 20,000 20,000 20,000
Female Rating (1378.93) (1378.93) (1378.93) (1378.93) (1034.20) (1034.20) (1378.93) (1378.93) (1378.93)
Connection PSI (bar)*
20,000
1/4 JIC4 (1378.93) 20MFAJ4M4 20MFAJ4M6 20MFAJ4M9
20,000
3/8 JIC6 (1378.93) 20MFAJ6M4 20MFAJ6M6 20MFAJ6M9
20,000
1/2 JIC8 (1378.93) 20MFAJ8M4 20MFAJ8M6 20MFAJ8M9
JIC
20,000
5/8 JIC10 (1378.93)
15,000
3/4" JIC12 (1034.20) 15MFAJ12M4 15MFAJ12M6 15MFAJ12M9
15,000
MALE END
20,000
3/8 SF375CX (1378.93)
20,000
9/16 SF562CX (1378.93)
20,000
3/4 SF750CX (1378.93) 20MFAM12J4
20,000
1 SF1000CX (1378.93)
60,000
High Pressure
(1034.20)
15,000
3/8 NPT (1034.20) 15MFAP6J6
15,000
1/2 NPT (1034.20)
10,000
3/4 NPT (689.45)
10,000
1 NPT (689.45)
Note: * The maximum pressure rating for an adapter is determined by the connection component with the
All adapters with Parker Autoclave connections are supplied with appropriate glands, collars, tube nuts LOWEST pressure rating; that is, the two end connections and the tubing or pipe used, whichever is
and sleeves unless specified without. LOWER.
JIC connections are not supplied with connection components. CAUTION: See appropriate pressure section in reference to proper selection of tubing.
30 All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold.
FEMALE END
Medium Pressure High Pressure National Pipe Thread (NPT)
3/4 1 1/4 3/8 9/16 1/4 3/8 1/2 3/4" 1"
F750CX F1000CX F250C F375C F562C NPT NPT NPT NPT NPT
20,000 20,000 60,000 60,000 60,000 15,000 15,000 15,000 10,000 10,000
(1378.93) (1378.93) (4136.85) (4136.85) (4136.85) (1034.20) (1034.20) (1034.20) (689.45) (689.45)
20MFAJ8M12 20MFAJ8M16
15MFAJ12M12 15MFAJ12M16
15MFAJ16M12 15MFAJ16M16
Parker AE Male/Female Adapters are available in a one-piece design. They are identical to the two piece
designs in length and can be ordered by adding the suffix - OP to the two piece adapter part numbers listed.
For prompt service, Parker Autoclave Engineers stocks select products. Consult factory.
All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold. 31
Adapters/Couplings - Male/Female JIC Adapters
32
Adapters/Couplings - EZ-Union Adapters
EZ-Union Adapter
O-Ring Seal
Female
Male Connection
Connection G
F
Nut
Ordering Procedure
20 EZ M4 M4
Pressure EZ- Male to Female "F" "G"
(X 1000 psi) EZMA- Male to Male Available End Connections
For Butt-Weld or specials contact factory. When ordering Male to Female adapters, Male connection is listed first.
Note: Special material EZ-Unions may be supplied with four flats in place of standard hex.
All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold. 33
EZ-Union Male to Female Adapters
20EZM4M4 SM250CX20 SF250CX20 20,000 (1379) 3.13 (79.50) 1.00 (25.40) 1.00 (25.40) 0.81 (20.57) 0.109 (2.77)
10EZM9M9 SM562CX20 SF562CX20 10,000 (690) 4.63 (117.60) 1.63 (41.40) 1.75 (44.45) 1.38 (34.93) 0.31 (7.92)
10EZM12M12 SM750CX20 SF750CX20 10,000 (690) 4.63 (117.60) 1.38 (35.05) 1.75 (44.45) 1.50 (38.10) 0.44 (11.13)
10EZM16M16 SM1000CX20 SF1000CX20 10,000 (690) 6.44 (163.58) 2.31 (58.67) 1.75 (44.45) 1.75 (44.45) 0.56 (14.27)
10EZP12M12 3/4" NPT SF750CX20 10,000 (690) 4.63 (117.60) 1.38 (35.05) 1.75 (44.45) 1.50 (38.10) 0.44 (11.13)
10EZM16P8 SM1000CX20 1/2" NPT 10,000 (690) 5.38 (136.65) 1.25 (31.75) 1.75 (44.45) 1.38 (35.05) 0.56 (14.27)
A
B
Male D
Connection C
F
Female
Connection
G
20EZMAH4H6 M250C M375C 20,000 (1379) 5.94 (150.88) 3.56 (90.42) 1.00 (25.40) 0.81 (20.57) 0.09 (2.29)
10EZMAP12M12 SM750CX20 3/4" NPT 10,000 (690) 6.50 (165.10) 3.25 (82.55) 1.75 (44.45) 0.87 (22.05)* 0.44 (11.13)
Male C
Connection
F
Male
D Connection
G
Note1: EZ-Unions are constructed from 316 SS and are supplied with a Viton o-ring as standard. *across flats
Maximum pressure rating is based on the lowest rating of any component. FFor prompt service, Parker Autoclave Engineers stocks select products. Consult factory.
Actual working pressure may be determined by tubing pressure rating, if lower.
34 All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold.
Adapters/Couplings - Butt-Weld Adapters
Butt-Weld Adapter
Butt-Weld End
Female
Connection
Butt-Weld Adapters
All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold. 35
Butt-Weld to Low-Pressure
M128W2B-XXS 3/4 SW500 10,000 689.5 1.19 (30.23) 2.00 (50.80) 0.81 (20.57)
Butt-Weld to Medium-Pressure
M24W6B-XS 1/8 SF250CX 8500 586.0 0.63 (15.88) 1.00 (25.40) 0.38 (9.53)
M26W6B-XS 1/8 SF375CX 8500 586.0 0.75 (19.05) 1.31 (33.32) 0.38 (9.53)
M44W6B-XS 1/4 SF250CX 8000 551.6 0.63 (15.88) 1.18 (29.97) 0.56 (14.27)
M46W6B-XS 1/4 SF375CX 8000 551.6 0.75 (19.05) 1.50 (38.10) 0.56 (14.27)
M49W6B-XS 1/4 SF562CX 8000 551.6 1.00 (25.40) 1.56 (39.67) 0.56 (14.27)
M64W6B-XS 3/8 SF250CX 6500 448.2 0.75 (19.05) 1.25 (31.75) 0.63 (15.88)
M66W6B-XS 3/8 SF375CX 6500 448.2 0.75 (19.05) 1.56 (39.67) 0.63 (15.88)
M69W6B-XS 3/8 SF562CX 6500 448.2 1.00 (25.40) 1.63 (41.28) 0.63 (15.88)
M612W6B-XS 3/8 SF750CX 6500 448.2 1.38 (34.93) 1.94 (49.20) 0.63 (15.88)
M84W6B-XS 1/2 SF250CX 6000 413.7 1.00 (25.40) 1.38 (34.93) 0.81 (20.57)
M86W6B-XXS 1/2" SF375CX 13000 896.3 1.00 (25.40) 1.75 (44.45) 0.81 (20.57)
M89W6B-XS 1/2 SF375CX 6000 413.7 1.00 (25.40) 1.81 (45.97) 0.81 (20.57)
M89W6B-XXS 1/2 SF562CX 10000 689.5 1.00 (25.40) 1.81 (45.97) 0.81 (20.57)
M812W6B-XXS 1/2 SF750CX 10000 689.5 1.38 (34.93) 2.13 (53.98) 0.81 (20.57)
M816W6B-XXS 1/2 SF1000CX 10000 689.5 1.75 (44.45) 2.81 (71.37) 0.81 (20.57)
M129W6B-XS 3/4 SF562CX 5000 344.7 1.19 (30.23) 1.81 (45.97) 0.81 (20.57)
M129W6B-160 3/4 SF562CX 7500 517.1 1.19 (30.23) 2.00 (50.80) 0.81 (20.57)
M129W6B-XXS 3/4 SF562CX 10000 689.5 1.19 (30.23) 2.00 (50.80) 0.81 (20.57)
M1212W6B-XXS 3/4 SF750CX 10000 689.5 1.38 (34.93) 2.06 (52.32) 0.81 (20.57)
M1216W6B-XXS 3/4 SF1000CX 10000 689.5 1.75 (44.45) 2.69 (68.25) 0.81 (20.57)
M1616W6B-XXS 1 SF1000CX 10000 689.5 1.75 (44.45) 3.25 (82.55) 1.31 (33.32)
Butt-Weld to High-Pressure
M169W3B-XXS 1 F562C 10000 689.5 1.38 (34.93) 2.44 (61.90) 1.22 (30.99)
B
C
Gland and collar supplied with high pressure connections. Note: For pressure rating see ordering procedure.
All Dimensions for reference only and are subject to change.
Maximum pressure rating is based on the lowest rating of any component. For prompt service, Parker Autoclave Engineers stocks select products. Consult factory.
Actual working pressure may be determined by piping pressure rating, contact factory.
36 All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold.
Adapters/Couplings - Header Couplings
Header Coupling
37.5
Ordering Procedure
HC F M16 W 625 DT
Header Female Available Welded Drilled
Coupling Connection End Connections Through
SAE 4130 - 4130
Inconel 625 - 625
2205 Duplex - 2205
316 SS - 316
A105 - 105
A105N - 105 Normalized
All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold. 37
Female Medium-Pressure Header Coupling Blind End
HCFM12W316 316 SS 10,000 (690) SF750CX20 1.75 (44.45) 3.00 (76.2) 1.05 (26.7) 1.32 (33.5) 0.44 (11.2)
HCFM12W105 SA-105 10,000 (690) SF750CX20 1.75 (44.45) 3.00 (76.2) 1.05 (26.7) 1.32 (33.5) 0.44 (11.2)
HCFM12W4130 SAE-4130 20,000 (1379) SF750CX20 1.75 (44.45) 3.00 (76.2) 1.05 (26.7) 1.32 (33.5) 0.44 (11.2)
HCFM12W2205 2205 Duplex 15,000 (1034) SF750CX20 1.75 (44.45) 3.00 (76.2) 1.05 (26.7) 1.32 (33.5) 0.44 (11.2)
HCFM16W316 316 SS 10,000 (690) SF1000CX20 1.75 (44.45) 2.62 (66.55) 1.00 (25.40) 1.38 (34.93) 0.56 (14.27)
HCFM16W2205 2205 Duplex 15,000 (1034) SF1000CX20 1.75 (44.45) 3.00 (76.2) 1.05 (26.7) 1.31 (33.27) 0.56 (14.27)
HCFH9W316 316SS 30,000 (2068) F562C 1.50 (38.10) 2.31 (58.67) 1.19 (30.18) 1.31 (33.27) 0.19 (4.75)
HCFH9W4130 SAE-4130 30,000 (2068) F562C 1.50 (38.10) 2.31 (58.67) 1.19 (30.18) 1.31 (33.27) 0.19 (4.75)
HCFH9W625 Inconel 625 30,000 (2068) F562C 1.50 (38.10) 2.31 (58.67) 1.19 (30.18) 1.31 (33.27) 0.19 (4.75)
HCFH16W4130 SAE-4130 20,000 (1379) F1000C43 1.75 (44.45) 3.00 (76.20) 1.05 (26.59) 1.32 (33.53) 0.44 (11.10)
HCFH16W625 Inconel 625 22,000 (1551) F1000C43 1.75 (44.45) 3.00 (76.20) 1.05 (26.59) 1.32 (33.53) 0.44 (11.10)
E
A D
Gland and collar supplied with high pressure connections. All Dimensions for reference only and are subject to change.
For prompt service, Parker Autoclave Engineers stocks select products. Consult factory.
Maximum pressure rating is based on the lowest rating of any component.
Actual working pressure may be determined by tubing pressure rating, if lower.
38 All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold.
Female Medium-Pressure Header Coupling Drill Through
HCFM4W316DT 316 SS 10,000 (690) SF250CX20 0.63 (16.0)* 1.19 (30.2) 0.56 (14.3) 0.54 (13.6) 0.11 (2.8)
HCFM9W316DT 316 SS 10,000 (690) SF562CX20 1.38 (35.1)* 2.44 (62.0) 1.13 (28.6) 1.32 (33.5) 0.36 (9.1)
HCFM9W4130DT SAE-4130 25,000 (1724) SF562CX20 1.38 (35.1) 2.44 (62.0) 1.13 (28.6) 1.32 (33.5) 0.36 (9.1)
HCFM12W4130DT SAE-4130 20,000 (1379) SF750CX 1.38 (35.1) 2.63 (66.68) 1.05 (26.7) 1.32 (33.5) 0.44 (11.2)
HCFM12W2205DT 2205 duplex 15,000 (1034) SF750CX20 1.75 (44.45) 3.00 (76.20) 1.05 (26.7) 1.32 (33.5) 0.44 (11.2)
HCFM16W316DT 316 SS 10,000 (690) SF1000CX20 1.75 (44.45) 3.00 (76.20) 1.05 (26.7) 1.32 (33.5) 0.56 (14.2)
HCFM16W316LDT 316L SS 10,000 (690) SF1000CX20 1.75 (44.45) 3.00 (76.20) 1.05 (26.7) 1.32 (33.5) 0.56 (14.2)
HCFM16W4130DT SAE-4130 20,000 (1379) SF1000CX20 1.75 (44.45) 3.00 (76.20) 1.05 (26.7) 1.32 (33.5) 0.56 (14.2)
HCFM16W105DT SA-105 12,000 (827) SF1000CX20 1.75 (44.45) 3.00 (76.20) 1.05 (26.7) 1.32 (33.5) 0.56 (14.2)
HCFM16W2205DT 2205 duplex 15,000 (1034) SF1000CX20 1.75 (44.45) 3.00 (76.20) 1.05 (26.7) 1.32 (33.5) 0.56 (14.2)
HCFM16W625DT Inconel 625 15,000 (1034) SF1000CX20 1.75 (44.45) 3.00 (76.20) 1.05 (26.7) 1.32 (33.5) 0.56 (14.2)
*across hex
HCFH9W316DT 316SS 30,000 (2068) F562C 1.50 (38.10) 2.31 (58.67) 1.19 (30.18) 1.31 (33.27) 0.19 (4.75)
HCFH9W4130DT SAE-4130 30,000 (2068) F562C 1.50 (38.10) 2.31 (58.67) 1.19 (30.18) 1.31 (33.27) 0.19 (4.75)
HCFH9W625DT Inconel 625 30,000 (2068) F562C 1.50 (38.10) 2.31 (58.67) 1.19 (30.18) 1.31 (33.27) 0.19 (4.75)
HCFH16W4130DT SAE-4130 20,000 (1379) F1000C43 1.75 (44.45) 3.00 (76.20) 1.05 (26.59) 1.32 (33.53) 0.44 (11.10)
HCFH16W625DT Inconel 625 22,000 (1551) F1000C43 1.75 (44.45) 3.00 (76.20) 1.05 (26.59) 1.32 (33.53) 0.44 (11.10)
B
C
E
A D
Gland and collar supplied with high pressure adapters. Note: For pressure rating see ordering procedure.
Maximum pressure rating is based on the lowest rating of any component. All Dimensions for reference only and are subject to change.
Actual working pressure may be determined by tubing pressure rating, if lower.
For prompt service, Parker Autoclave Engineers stocks select products. Consult
factory.
All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold. 39
Adapters/Couplings - Bulkhead Adapters
Bulkhead Adapter
Panel Nut
*
"A" "B"
Adapter
Ordering Procedure
20 BA M J16 F H4
Pressure Bulkhead *Male Connection Female Connection
(X 1000 psi) Adapter Female Male
J4 - 1/4 JIC L4 - 1/4 Low Pressure M4 - 1/4 Medium Pressure H4 - 1/4 High Pressure P4 - 1/4 NPT
J6 - 3/8 JIC L6 - 3/8 Low Pressure M6 - 3/8 Medium Pressure H6 - 3/8 High Pressure P6 - 3/8 NPT
J8 - 1/2 JIC L8 - 1/2 Low Pressure M9 - 9/16 Medium Pressure H9 - 9/16 High Pressure P8 - 1/2 NPT
J10 - 5/8 JIC M12 - 3/4 Medium Pressure RH9 - 9/16 Reverse High Pressure
J12 - 3/4 JIC M16 - 1 Medium Pressure RH12 - 3/4 Reverse High Pressure
J16 - 1 JIC RH16 - 1 Reverse High Pressure
Note: Special material adapters may be supplied with four flats in place of standard hex.
40 All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold.
Reverse High to Medium-Pressure
Gland and collar supplied with adapter. Note: For pressure rating see ordering procedure.
All Dimensions for reference only and are subject
Maximum pressure rating is based on the lowest rat- to change.
ing of any component. Actual working pressure may
be determined by tubing pressure rating, if lower. For prompt service, Parker Autoclave Engineers
stocks select products. Consult factory.
All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold. 41
JIC to Low Pressure
1/4 15BAMJ4FL4
3/8
1/2
1/4 20BAMJ4FH4
3/8 20BAMJ6H4
1/2
Gland and collar supplied with adapter. Note: For pressure rating see ordering procedure.
All Dimensions for reference only and are subject
Maximum pressure rating is based on the lowest rat- to change.
ing of any component. Actual working pressure may
be determined by tubing pressure rating, if lower. For prompt service, Parker Autoclave Engineers
stocks select products. Consult factory.
42 All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold.
Reverse High Pressure to Medium Pressure
20BAMRH9FM4 9/16 SF250CX 0.81 (20.62) 2.56 (65.0) 1.22 (31.0) 0.38 (9.65) 1.00 (25.40)
20BAMRH9FM6 9/16 SF375CX 0.94 (23.88) 2.63 (66.80) 1.13 (28.70) 0.38 (9.65) 1.00 (25.40)
20BAMRH9FM9 9/16 SF562CX 1.13 (28.58) 3.00 (76.20) 1.28 (32.51) 0.38 (9.65) 1.38 (34.93)
20BAMRH12FM9 3/4 SF562CX 1.13 (28.58) 3.13 (79.50) 1.41 (35.81) 0.38 (9.65) 1.38 (34.93)
20BAMRH12FM16 3/4 SF1000CX 1.94 (49.28) 4.26 (108.20) 2.13 (54.10) 0.38 (9.65) 2.13 (54.10)
20BAMRH16FM16 1 SF1000CX 1.94 (49.28) 4.41 (112.01) 2.28 (57.91) 0.38 (9.65) 2.13 (54.10)
40BAMRH9FH4 9/16 F250C 0.94 (23.88) 2.50 (63.50) 1.00 (25.40) 0.38 (9.65) 1.00 (25.40)
40BAMRH9FH9 9/16 F562C 1.69 (42.85) 3.38 (85.85) 1.50 (38.10) 0.38 (9.65) 1.88 (47.75)
30BAMRH12FH9 3/4 F562C 1.69 (42.85) 3.50 (88.90) 1.62 (41.15) 0.38 (9.65) 1.88 (47.75)
15BAMP4FM4 1/4 SF250CX 0.81 (20.62) 2.56 (65.02) 1.22 (31.01) 0.38 (9.65) 1.00 (25.40)
15BAMP4FM6 1/4 SF375CX 0.94 (23.88) 2.69 (68.33) 1.31 (33.35) 0.38 (9.65) 1.00 (25.40)
15BAMP6FM6 3/8 SF375CX 0.94 (23.88) 2.75 (69.85) 1.25 (31.75) 0.38 (9.65) 1.00 (25.40)
B
C D
Maximum
E A
Hex Panel Hole
Drill Size
For prompt service, Parker Autoclave Engineers stocks select products. Consult factory.
All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold. 43
JIC to Low Pressure
15BAMJ4FL4 1/4 SW250 0.94 (23.88) 2.29 (58.04) 0.91 (23.11) 0.38 (9.65) 1.00 (25.40)
20BAMJ4FM4 1/4 SF250CX 0.81 (20.62) 2.25 (57.15) 0.91 (23.11) 0.38 (9.65) 1.00 (25.40)
20BAMJ4FM6 1/4 SF375CX 0.81 (20.62) 2.44 (61.93) 0.94 (23.88) 0.38 (9.65) 1.00 (25.40)
20BAMJ4FM12 1/4 SF750CX 1.69 (42.85) 2.94 (74.68) 1.22 (31.0) 0.38 (9.65) 1.88 (47.75)
20BAMJ6FM4 3/8 SF250CX 0.81 (20.62) 2.25 (57.15) 0.91 (23.11) 0.38 (9.65) 1.00 (25.40)
20BAMJ6FM6 3/8 SF375CX 0.94 (23.88) 2.44 (61.98) 0.94 (23.88) 0.38 (9.65) 1.00 (25.40)
20BAMJ6FM9 3/8 SF562CX 1.13 (28.58) 2.75 (69.85) 1.16 (29.46) 0.38 (9.65) 1.38 (34.93)
20BAMJ6FM12 3/8 SF750CX 1.69 (42.85) 2.94 (74.68) 1.22 (31.0) 0.38 (9.65) 1.88 (47.75)
20BAMJ8FM6 1/2 SF375CX 0.81 (20.62) 2.53 (64.26) 1.03 (26.16) 0.38 (9.65) 1.00 (25.40)
20BAMJ8FM9 1/2 SF562CX 1.13 (28.58) 3.00 (76.20) 1.41 (35.69) 0.38 (9.65) 1.38 (34.93)
20BAMJ8FM12 1/2 SF750CX 1.69 (42.85) 3.13 (79.38) 1.41 (35.69) 0.38 (9.65) 1.88 (47.75)
20BAMJ8FM16 1/2 SF1000CX 1.94 (49.20) 4.36 (110.72) 2.23 (56.62) 0.50 (12.70) 1.87 (47.50*)
*Dimension across flats
20BAMJ4FH4 1/4 F250C 0.94 (23.80) 2.44 (61.90) 1.06 (26.97) 0.38 (9.65) 1.00 (25.40)
20BAMJ6FH4 3/8 F250C 0.94 (23.80) 2.47 (62.74) 1.09 (27.79) 0.38 (9.65) 1.00 (25.40)
B
C D
Maximum
E A
Hex Panel Hole
Drill Size
For prompt service, Parker Autoclave Engineers stocks select products. Consult factory.
44 All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold.
Adapters/Couplings - SAE O-Ring Adapters
Parker Autoclave Engineers also offers a line of components that assist in adapting into and out of specialized connections with
Parker Autoclave Engineers products. Along with the adapters shown, Parker Autoclave Engineers can provide other special
adapters to fill your requirements. Contact your local Sales representative for information.
O-Ring
MC240
All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold. 45
Adapters/Couplings - Female Tube Caps / Gauge Connectors
Tube Caps
Parker Autoclave Engineers offers a line of tube caps used to seal the
ends of tubing. Caps are used when pressure testing lengths of tubes
or capping off sections of systems for isolation or pressure tests.
46 All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold.
Female Tube Caps - JIC
B
Gauge Connectors
Gauge Connectors
To Fit This Gauge Connection 1/4 NPT 1/2 NPT 1/2 NPS
With This Female Tubing Connection 60,000 PSI 60,000 PSI 60,000 PSI
(4136.8 bar) (4136.8 bar) (4136.8 bar)
Gauge Connectors
Medium
Pressure 9/16 SF562CX 101F-1707
NPT: National Pipe Thread Note: For gauge connector without collars and glands, add the following suffix: -WO
NPS: National Straight Pipe Thread For gauge connector for sour gas applications, add the following suffix: -SOG or -SOGWO
All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold. 47
Gauge Connectors
CG4400 Tube Cone 1/4 60000 (4136.7) 1.00 (25.4) .813 (20.6)
CG4800 Tube Cone 1/4 60000 (4136.7) 1.19 (30.1) .94 (23.8) See Figure 1
CG9800 Tube Cone 9/16 60000 (4136.7) 1.50 (38.1) 1.25 (31.8)
B B
B
A A A
Hex Hex Hex
*Maximum pressure rating is based on the lowest rating of any component. Actual working pressure may be determined by tubing pressure rating, if lower.
Note: 1) For pressure rating see selection chart. These adapters are not intended as couplings. For prompt service, Parker Autoclave Engineers
2) Operation of this connector will depend on the inlet hole configuration in the gauge. Check to see that tubing will seal. stocks select products. Consult factory.
WARNING
FAILURE, IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS AND/OR SYSTEMS DESCRIBED HEREIN OR RELATED ITEMS CAN CAUSE DEATH, PERSONAL INJURY AND PROPERTY DAMAGE.
This document and other information from Parker Hannifin Corporation, its subsidiaries and authorized distributors provide product and/or system options for further investigation by users having technical
expertise. It is important that you analyze all aspects of your application and review the information concerning the product or system in the current product catalog. Due to the variety of operating conditions
and applications for these products or systems, the user, through its own analysis and testing, is solely responsible for making the final selection of the products and systems and assuring that all performance,
safety and warning requirements of the application are met. The products described herein, including without limitation, product features, specifications, designs, availability and pricing, are subject to change by
Parker Hannifin Corporation and its subsidiaries at any time without notice.
Offer of Sale
The items described in this document are available for sale by Parker Hannifin Corporation, its subsidiaries or its authorized distributors. Any sale contract entered by Parker will be governed by the provisions
stated in Parker's standard terms and conditions of sale (copy available upon request).
2013 Parker Hannifin Corporation | Autoclave Engineers is a registered trademark of the Parker Hannifin Corporation 02-0127SE January2013
Instrumentation Products Division Parker Hannifin Manufacturing Ltd. Caution! Parker Autoclave Engineers Valves, Fittings and Tools are
Autoclave Engineers Operation Instrumentation Products Division, Europe not designed to work with common commercial instrument tubing
and will only work with tubing built to Parker Autoclave Engineers
8325 Hessinger Drive Industrial Estate Whitemill
AES Specifications. Failure to do so will void warranty.
Erie, Pennsylvania 16509-4679 USA Wexford, Republic of Ireland
PH: 814-860-5700 FAX: 814-860-5811 PH: 353 53 914 1566
www.autoclave.com FAX: 353 53 914 1582 ISO-9001 Certified
Ball Valves
2-Way Series
Pressures to 20,000 psi (1379 bar)
These ball valves can also be modified to incorporate the use of Flow Configuration
special materials, seals for high temperature applications, subsea
models, and valve actuators.
All general terms and conditions of sale, including limitations of our liability, apply to all products andwww.autoclave.com
services sold. 1
Ball Valves - 2-Way Series (1/4 Orifice)
Pressures to 20,000 psi (1379 bar) .250 (6.35mm) Orifice
15,000 (1034)
STOPPING DEVICE
W125, SW250, SW375, & NPT CONNECTIONS
PRESSURE PSIG
PRESSURE BAR
PACKING GLAND
THRUST WASHER
LOCKING PIECE
10,000 (690)
SW500 CONNECTION
SPRING ENERGIZED SEAL
PEEK SEATS
LOCKNUT
SEAT GLAND
5,000 (345)
SEAT RETAINER Pressure ratings are determined by the end connections chosen, see chart.
NOTE: Ball valves are not recommended for critical gas applications such as Hydrogen, Helium or other small molecular gases.
Ordering Procedure
For complete information on available end connections and material options, see next page. 2-way ball valves are furnished complete with tube or
pipe connections.
2B 4 S 20 M9 XXX
Valve Ball Material Pressure End Connection Options
Series Orifice (X 1000 psi)
2B: 2-way Diameter S -316SS M9 - SF562CX20 HT - High Temperature
4-1/4 (For material options (See Chart on next (Ball Valve Actuators,
(6.35 mm) contact factory) page) see next page)
2 All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold.
End Connection Options
Seat Gland
Catalog End Connection MAWP @ Hex
Number Number Connection Room Temperature Inches(mm)
All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold. 3
Ball Valves - 2-Way Series (3/8 Orifice)
Pressures to 20,000 psi (1379 bar) .375 (9.52mm) Orifice
TEMPERATURE C
STAINLESS STEEL HANDLE
(-18) (38) (93) (150) (204) (260)
20,000 (1379)
SF CONNECTION
ONE PIECE BALL
AND STEM
PRESSURE BAR
PACKING GLAND
THRUST WASHER
LOCKING PIECE 10,000 (690)
SPRING ENERGIZED SEAL SW500 CONNECTION
CARBON FILLED
PEEK SEATS
LOCKNUT
SEAT GLAND
5,000 (345)
SEAT RETAINER *pressure ratings are determined by the end connections chosen, see chart.
Pressure ratings are determined by the end connections chosen, see chart.
NOTE: Ball valves are not recommended for critical gas applications such as Hydrogen, Helium or other small molecular gases.
Ordering Procedure
For complete information on available end connections and material options, see next page. 2-way ball valves are furnished complete with tube
or pipe connections.
2B 6 S 20 M9 XXX
Valve Ball Material Pressure End Connection Options
Series Orifice (X 1000 psi)
2B: 2-way Diameter S - 316SS M9 - SF562CX20 HT - High Temperature
(For material options (See Chart on next (Ball Valve Acutators,
6-3/8
contact factory) page) see next page.)
(9.52 mm)
4 All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold.
End Connection Options
Seat Gland
Catalog End Connection MAWP @ Hex
Number Number Connection Room Temperature Inches(mm)
All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold. 5
Ball Valves - 2-Way Series (1/2 Orifice)
Pressures to 15,000 psi (1034 bar) .500 (12.7mm) Orifice
TEMPERATURE C
(-18) (38) (93) (150) (204) (260)
ONE PIECE BALL STOPPING DEVICE
AND STEM 15,000 (1034)
SM CONNECTIONS
PACKING GLAND
THRUST WASHER
LOCKING PIECE
(690)
PRESSURE PSIG
10,000
PRESSURE BAR
SPRING ENERGIZED SEAL CARBON FILLED
PEEK SEATS NPT CONNECTIONS
LOCKNUT SEAT GLAND
5,000 (345)
SEAT RETAINER
Pressure ratings are determined by the end connections chosen, see chart.
NOTE: Ball valves are not recommended for critical gas applications such as Hydrogen, Helium or other small molecular gases.
Ordering Procedure
For complete information on available end connections and material options, see next page. 2-way ball valves are furnished complete with
tube or pipe connections.
2B 8 S 15 M12 XXX
Valve Ball Material Pressure End Connection Options
Series Orifice (X 1000 psi)
2B: 2-way Diameter S -316SS M12 - SF750CX20 HT - High Temperature
(For material options contact (See Chart on next (Ball Valve Acutators,
8-1/2
factory) page) see next page.)
(12.7 mm)
6 All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold.
End Connection Options
Seat Gland
Catalog End Connection MAWP @ Hex
Number Number Connection Room Temperature Inches(mm)
2B8S10P12 P12 3/4 NPT 10,000 psi (690 bar) 1.75 (44.5)
All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold. 7
Ball Valve Dimensions - inches (mm)
VALVE MODELS
2B4S 2B6S 2B8S E*
4.33 4.97 5.97 E
A (109.99) (126.30) (151.64)
L
1.91 2.50 3.09 C
(48.41) (63.50) (78.58)
B
Block 1.00 1.38 1.75
Thickness (25.40) (34.92) (44.45)
C (Diameter)
VALVE MODELS
2B4S 2B6S 2B8S D (Typical Diameter)
See Note:
1.500 2.000 3.000
A (38.10) (50.80) (76.20)
C 1.06
(26.92)
1.50
(38.10)
1.88
(47.63)
B
D
0.28
(7.11)
0.28
(7.11)
0.28
(7.11)
A
All dimensions are for reference only
and are subject to change without notice.
Note: Body mounting 1/4 - 20 thread
8 All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold.
Ball Valves - 2-Way Series (3/4 Orifice)
Pressures to 15,000 psi (1034 bar) .750 (19.05mm) Orifice
TEMPERATURE C
(-18) (38) (93) (150) (204) (260)
ONE PIECE BALL STOPPING DEVICE
AND STEM
15,000 (1034)
1/2 & SF CONNECTIONS
PACKING GLAND
THRUST WASHER
LOCKING PIECE
(690)
PRESSURE PSIG
10,000
PRESSURE BAR
SPRING ENERGIZED SEAL CARBON FILLED
PEEK SEATS 1 & 3/4 NPT CONNECTIONS
LOCKNUT SEAT GLAND
5,000 (345)
VITON O-RING
TEMPERATURE F
PEEK BEARING
SEAT RETAINER
Pressure ratings are determined by the end connections chosen, see chart.
NOTE: Ball valves are not recommended for critical gas applications such as Hydrogen, Helium or other small molecular gases.
Ordering Procedure
For complete information on available end connections and material options, see next page. 2-way ball valves are furnished complete with
tube or pipe connections.
2B 12 S 15 M16 XXX
Valve Ball Material Pressure End Connection Options
Series Orifice (X 1000 psi)
2B: 2-way Diameter S -316SS M16 - SF1000CX10 HT - High Temperature
(For material options contact (See Chart on next (Ball Valve Acutators,
12-3/4
factory) page) see next page.)
(19.05 mm)
All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold. 9
End Connection Options
Seat Gland
Catalog End Connection MAWP @ Hex
Number Number Connection Room Temperature Inches(mm)
2B12S10P12 P12 3/4" NPT 10,000 psi (690 bar) 1.88 (47.6)
2B12S10P16 P16 1" NPT 10,000 psi (690 bar) 1.88 (47.6)
10 All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold.
Ball Valve Dimensions - inches (mm)
22.00
(558.8)
11.00
(279.4)
.41 (10.4)
TYPICAL DIAMETER
3.25
(82.6)
10.13 3.00 (76.2)
(257.3) BLOCK THICKNESS
1.63
(41.4)
0.69 (17.5)
TYPICAL
2.47
(62.7)
4.50
(114.3)
4.50
(114.3)
9.18
(233.2)
2.38 (60.3)
.44 (11.2)
(Typical Diameter)
See Note:
1.63
(41.4)
3.25
(82.6)
All dimensions are for reference only
and are subject to change without notice.
NOTE: Body mounting 3/8-16 thread
All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold. 11
Ball Valves - 2-Way Series (1 Orifice)
Pressures to 10,000 psi (690 bar) 1.000 (25.40mm) Orifice
TEMPERATURE C
(-18) (38) (93) (150) (204) (260)
ONE PIECE BALL STOPPING DEVICE
AND STEM 15,000 (1034)
PACKING GLAND
THRUST WASHER
LOCKING PIECE
(690)
PRESSURE PSIG
10,000
PRESSURE BAR
SPRING ENERGIZED SEAL CARBON FILLED
PEEK SEATS NPT, SAE & SM CONNECTIONS
LOCKNUT SEAT GLAND
5,000 (345)
NOTE: Ball valves are not recommended for critical gas applications such as Hydrogen, Helium or other small molecular gases.
Ordering Procedure
For complete information on available end connections and material options, see next page. 2-way ball valves are furnished complete with
tube or pipe connections.
2B 16 S 10 MA24 XXX
Valve Ball Material Pressure End Connection Options
Series Orifice (X 1000 psi)
2B: 2-way Diameter S -316SS MA24 - SM1500CX10 HT - High Temperature
(For material options contact (See Chart on next (Ball Valve Acutators,
16-1.0
factory) page) see next page.)
(25.40 mm)
12 All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold.
End Connection Options
Seat Gland
Catalog End Connection MAWP @ Hex
Number Number Connection Room Temperature Inches(mm)
2B16S10MA24 M24 SM1500CX10 (Male) 10,000 psi (690 bar) 1.88 (47.6)*Square
2B16S10S16 S16 1" SAE (Female) 10,000 psi (690 bar) 1.88 (47.6)
2B16S10P16 P16 1" NPT (Female) 10,000 psi (690 bar) 1.88 (47.6)
All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold. 13
Ball Valve Dimensions - inches (mm)
28.00
(711.2)
14.00
(355.6)
.53 (13.5)
TYPICAL DIAMETER
4.00
(101.6)
11.87 3.38 (85.9)
(301.5) BLOCK THICKNESS
2.00
(50.8)
0.88 (22.2)
TYPICAL 3.10
(78.6)
5.46
L (138.6)
5.00
(127.00)
8.41
(213.7) Female Connection Only
20.74
(526.7) *SM1500CX20 Connection Only
2.94 (74.7)
.44 (11.2)
(Typical Diameter)
See Note:
.750 (19.1)
1.500
(38.1)
2.000
(50.8)
4.000
(101.6)
All dimensions are for reference only
and are subject to change without notice.
NOTE: Body mounting 3/8-16 thread
14 All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold.
All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold. 15
WARNING
FAILURE, IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS AND/OR SYSTEMS DESCRIBED HEREIN OR RELATED ITEMS CAN CAUSE DEATH, PERSONAL INJURY
AND PROPERTY DAMAGE.
This document and other information from Parker Hannifin Corporation, its subsidiaries and authorized distributors provide product and/or system options for further investiga-
tion by users having technical expertise. It is important that you analyze all aspects of your application and review the information concerning the product or system in the current
product catalog. Due to the variety of operating conditions and applications for these products or systems, the user, through its own analysis and testing, is solely responsible
for making the final selection of the products and systems and assuring that all performance, safety and warning requirements of the application are met. The products described
herein, including without limitation, product features, specifications, designs, availability and pricing, are subject to change by Parker Hannifin Corporation and its subsidiaries at
any time without notice.
Offer of Sale
The items described in this document are available for sale by Parker Hannifin Corporation, its subsidiaries or its authorized distributors. Any sale contract entered by Parker will be
governed by the provisions stated in Parker's standard terms and conditions of sale (copy available upon request).
2013 Parker Hannifin Corporation | Autoclave Engineers is a registered trademark of the Parker Hannifin Corporation 02-0105SE January2013
Instrumentation Products Division Parker Hannifin Manufacturing Ltd. Caution! Parker Autoclave Engineers Valves, Fittings and Tools are
Autoclave Engineers Operation Instrumentation Products Division, Europe not designed to work with common commercial instrument tubing
8325 Hessinger Drive Industrial Estate Whitemill and will only work with tubing built to Parker Autoclave Engineers
AES Specifications. Failure to do so will void warranty.
Erie, Pennsylvania 16509-4679 USA Wexford, Republic of Ireland
PH: 814-860-5700 FAX: 814-860-5811 PH: 353 53 914 1566
www.autoclave.com
16 All general terms andFAX: 353 53 of
conditions 914 1582
sale, including limitations of our liability, apply to all products and services sold. ISO-9001 Certified
Ball Valves
3-Way Series
Pressures to 20,000 psi (1379 bar)
All general terms and conditions of sale, including limitations of our liability, apply to all products andwww.autoclave.com
services sold. 1
Ball Valves - 3/16" 3-Way Series
Pressures to 20,000 psi (1379 bar) .187 (4.77mm) Orifice
TEMPERATURE C
STAINLESS STEEL HANDLE
(-18) (38) (93) (150) (204) (260)
20,000 (1379)
SF & F CONNECTIONS
SET SCREW
See Note
STOPPING DEVICE
ONE PIECE BALL
AND STEM 15,000 (1034)
PRESSURE PSIG
PRESSURE BAR
PACKING GLAND
W125, SW250, SW375, & NPT CONNECTIONS
THRUST WASHER
LOCKING PIECE
5,000 (345)
Pressure ratings are determined by the end connections chosen, see chart.
Note: Maximum side connection inlet pressure 15,000 psi (1034 bar)
NOTE: Ball valves are not recommended for critical gas applications such as Hydrogen, Helium or other small molecular gases.
Ordering Procedure
For complete information on available end connections and material options, see next page. 3-way ball valves are furnished complete with
tube or pipe connections.
3B 3 S 20 M9 XXX
Valve Ball Material Pressure End Connection Options
Series Orifice (X 1000 psi)
3B: 3-way Diameter S -316SS M9 - SF562CX20 HT - High Temperature
3BD: 3-way diverter (For material options (See Chart on (Ball Valve Actuators,
3-3/16
contact factory) next page) see next page)
(4.77 mm)
2 All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold.
End Connection Options
Catalog End Connection MAWP @ Hex
Number Number Connection Room Temperature Inches(mm)
*3-WayDiverter
*3-Way Diverter Valve
Valve 3-Way Ball
3-Way BallValve
Valve
90 Turn
90 Turn 180
180 Turn
Turn
*The Diverter Valve design permits inlet flow through the bottom port. Outlet flow may be diverted to either valve side port.
All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold. 3
Ball Valves - 3/8" 3-Way Series
Pressures to 15,000 psi (1034 bar) .328 (8.33mm) Orifice
(690)
PRESSURE BAR
10,000
LOCKNUT
BELLEVILLE BACKUP SW500 CONNECTION
SEAT GLAND
O-RING
5,000 (345)
Pressure ratings are determined by the end connections chosen, see chart.
Side connection pressure not recommended.
NOTE: Ball valves are not recommended for critical gas applications such as Hydrogen, Helium or other small molecular gases.
Ordering Procedure
For complete information on available end connections and material options, see next page. 3-way ball valves are furnished complete with tube or
pipe connections.
3B 6 S 15 M9 XXX
Valve Ball Material Pressure End Connection Options
Series Orifice (X 1000 psi)
3B: 3-way Diameter S -316SS M9 - SF562CX20 HT - High Temperature
3BD: 3-way diverter
6-3/8 (For material options (See Chart on next (Ball Valve Actuators,
(9.52 mm) contact factory) page) see next page)
4 All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold.
End Connection Options
See ball valve option/details section for end connection details, material, and high temperature options.
*3-Way Diverter
*3-Way Diverter Valve
Valve 3-WayBall
3-Way BallValve
Valve
90
90 Turn
Turn 180Turn
180 Turn
*The Diverter Valve design permits inlet flow through the bottom port. Outlet flow may be diverted to either valve side port.
All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold. 5
Ball Valves - 1/2" 3-Way Series
Pressures to 10,000 psi (690 bar) .500 (12.7mm) Orifice
TEMPERATURE C
(-18) (38) (93) (150) (204) (260)
ONE PIECE BALL
STOPPING DEVICE 15,000 (1034)
AND STEM
PACKING GLAND
SET SCREW
(690)
PRESSURE BAR
PRESSURE PSIG
5,000 (345)
NOTE: Ball valves are not recommended for critical gas applications such as Hydrogen, Helium or other small molecular gases.
Ordering Procedure
For complete information on available end connections and material options, see next page. 3-way ball valves are furnished complete with
tube or pipe connections.
3B 8 S 10 M12 XXX
Valve Ball Material Pressure End Connection Options
Series Orifice (X 1000 psi)
3B: 3-way Diameter S -316SS M12 - SF750CX20 HT - High Temperature
3BD: 3-way diverter
8-1/2 (For material options (See Chart on (Ball Valve Actuators,
(12.7 mm) contact factory) next page) see next page)
6 All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold.
End Connection Options
See ball valve options for end connection details, material, and high temperature options.
*3-WayDiverter
*3-Way Diverter Valve
Valve 3-Way
3-WayBall
Ball Valve
Valve
90 Turn
90 Turn 180Turn
180 Turn
*The Diverter Valve design permits inlet flow through the bottom port. Outlet flow may be diverted to either valve side port.
All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold. 7
Ball Valve Dimensions - inches (mm)
VALVE MODELS
3B3S/3BD3S 3B6S/3BD6S 3B8S/3BD8S
E
5.64 6.55 7.83
A (143.35) (166.37) (198.79) D
4.72 5.74 7.77
B (119.94) (145.79) (197.36)
C
2.50 3.00 4.13 G K TYPICAL DIAMETER
(63.50) (76.20) (104.78)
BLOCK THICKNESS
D
3.37
(85.55)
4.99
(126.82)
5.12
(130.04)
H
3.90 5.52 10.25 J
E (99.02) (140.32) (260.35) TYPICAL
F
1.13 1.38 1.66
A F
(28.58) (34.93) (42.16)
G
1.50 2.00 3.00 L
(38.10) (50.80) (76.20)
M
0.97 1.19 1.70 C
(24.64) (30.22) (43.18)
B
Block 1.00 1.38 1.75
Thickness (25.40) (34.92) (44.45)
WARNING
FAILURE, IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS AND/OR SYSTEMS DESCRIBED HEREIN OR RELATED ITEMS CAN CAUSE DEATH, PERSONAL INJURY AND PROPERTY DAMAGE.
This document and other information from Parker Hannifin Corporation, its subsidiaries and authorized distributors provide product and/or system options for further investigation by users having technical
expertise. It is important that you analyze all aspects of your application and review the information concerning the product or system in the current product catalog. Due to the variety of operating conditions
and applications for these products or systems, the user, through its own analysis and testing, is solely responsible for making the final selection of the products and systems and assuring that all performance,
safety and warning requirements of the application are met. The products described herein, including without limitation, product features, specifications, designs, availability and pricing, are subject to change by
Parker Hannifin Corporation and its subsidiaries at any time without notice.
Offer of Sale
The items described in this document are available for sale by Parker Hannifin Corporation, its subsidiaries or its authorized distributors. Any sale contract entered by Parker will be governed by the provisions
stated in Parker's standard terms and conditions of sale (copy available upon request).
2013 Parker Hannifin Corporation | Autoclave Engineers is a registered trademark of the Parker Hannifin Corporation 02-0106SE January2013
Instrumentation Products Division Parker Hannifin Manufacturing Ltd. Caution! Parker Autoclave Engineers Valves, Fittings and Tools are
not designed to work with common commercial instrument tubing
Autoclave Engineers Operation Instrumentation Products Division, Europe
and will only work with tubing built to Parker Autoclave Engineers
8325 Hessinger Drive Industrial Estate Whitemill AES Specifications. Failure to do so will void warranty.
Erie, Pennsylvania 16509-4679 USA Wexford, Republic of Ireland
PH: 814-860-5700 FAX: 814-860-5811 PH: 353 53 914 1566
8
www.autoclave.com
All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold.
FAX: 353 53 914 1582 ISO-9001 Certified
Ball Valves
4-Way Series
Pressures to 10,000 psi (690 bar)
All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold.
www.autoclave.com 1
Ball Valves - 4-Way Series (3/8 Orifice)
Pressures to 10,000 psi (690 bar) .375 (9.52mm) Orifice
TEMPERATURE C
(-18) (38) (93) (150) (204) (260)
15,000 (1034)
STOPPING DEVICE
ONE PIECE BALL
AND STEM
PACKING GLAND
SET SCREW
10,000 (690)
PRESSURE PSIG
PRESSURE BAR
THRUST WASHER LOCKING PIECE
SW500 NPT & SF CONNECTIONS
STEM SEAL BELLEVILLE WASHERS
BELLEVILLE BACKUP
LOCKNUT SEAT GLAND
5,000 (345)
NOTE: Ball valves are not recommended for critical gas applications such as Hydrogen, Helium or other small molecular gases.
Ordering Procedure
For complete information on available end connections and material options, see next page. 4-way ball valves are furnished complete with
tube or pipe connections.
4B 6 S 10 M9 XXX
Valve Ball Material Pressure End Connection Options
Series Orifice (X 1000 psi)
4B: 4-way crossover Diameter S -316SS M9 - SF562CX20 HT - High Temperature
4BS: 4-way switching
6-3/8 (For material options (See Chart on (Ball Valve Actuators,
(9.52 mm) contact factory) next page) see next page)
2 All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold.
End Connection Options
C C C C C
B D B D
B D B D B D
A A
A A A
C C
C C C
B D B D
B D B D B D
A A
A A A
44-Way Crossover
Way Crossover
4-Way Switching
90 Turn
90 Turn 4-Way Switching
180 Turn
180"D"
(supplied with Turn
port plugged)
(supplied with "D" port plugged)
VALVE MODELS
4B6S/4BS6S E
5.81 D
A (147.57)
6.79
B (172.47)
G K DIAMETER TYPICAL
3.50
C (88.90)
H BLOCK THICKNESS
5.13
D (130.18)
J
10.25 A TYPICAL
E (260.35)
1.63
F
F (41.28)
L
2.63
G (66.68)
1.13
H (33.34)
0.41
J (10.32) C/2
K 0.28 C
(7.11)
B
2.97 TYPICAL
L (75.39)
Block 3.50
Thickness (88.90)
2.63
A (66.68)
1.31
B (33.34) B
1.88
C (47.63) A
All dimensions are for reference only
0.28
D (7.11)
and are subject to change without notice.
WARNING
FAILURE, IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS AND/OR SYSTEMS DESCRIBED HEREIN OR RELATED ITEMS CAN CAUSE DEATH, PERSONAL INJURY AND PROPERTY DAMAGE.
This document and other information from Parker Hannifin Corporation, its subsidiaries and authorized distributors provide product and/or system options for further investigation by users having technical
expertise. It is important that you analyze all aspects of your application and review the information concerning the product or system in the current product catalog. Due to the variety of operating conditions
and applications for these products or systems, the user, through its own analysis and testing, is solely responsible for making the final selection of the products and systems and assuring that all performance,
safety and warning requirements of the application are met. The products described herein, including without limitation, product features, specifications, designs, availability and pricing, are subject to change by
Parker Hannifin Corporation and its subsidiaries at any time without notice.
Offer of Sale
The items described in this document are available for sale by Parker Hannifin Corporation, its subsidiaries or its authorized distributors. Any sale contract entered by Parker will be governed by the provisions
stated in Parker's standard terms and conditions of sale (copy available upon request).
2013 Parker Hannifin Corporation | Autoclave Engineers is a registered trademark of the Parker Hannifin Corporation 02-0107SE January2013
Instrumentation Products Division Parker Hannifin Manufacturing Ltd. Caution! Parker Autoclave Engineers Valves, Fittings and Tools are
Autoclave Engineers Operation Instrumentation Products Division, Europe not designed to work with common commercial instrument tubing
and will only work with tubing built to Parker Autoclave Engineers
8325 Hessinger Drive Industrial Estate Whitemill
AES Specifications. Failure to do so will void warranty.
Erie, Pennsylvania 16509-4679 USA Wexford, Republic of Ireland
PH: 814-860-5700 FAX: 814-860-5811 PH: 353 53 914 1566
4
www.autoclave.com
All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold.
FAX: 353 53 914 1582 ISO-9001 Certified
Ball Valves
Double Block and Bleed
6DB Series
Pressures to 15,000 psi (1035 bar)
www.autoclave.com
Ball Valves - 6DB Series
Pressures to 15,000 psi (1034 bar) .328 (8.33mm) Orifice
TEMPERATURE C
(-18) (38) (93) (150) (204) (260)
15,000 (1034)
SF & NPT CONNECTIONS
PRESSURE PSIG
PRESSURE BAR
(690)
10,000
SW500 CONNECTION
5,000 (345)
Pressure ratings are determined by the end connections chosen, see chart.
STOPPING DEVICE
PACKING GLAND
LOCK NUT LOCK NUT
LOCKING PIECE
SEAT GLANDS SEAT GLANDS
THRUST WASHER
SPRING ENERGIZED
SEALS
SEATS
O-RING O-RING
BEARING BEARING
BOTTOM GLAND
VENT CONNECTION BOTTOM GLAND
on back side
VENT VALVE
NOTE: Ball valves are not recommended for critical gas applications such as Hydrogen, Helium or other small molecular gases.
Ordering Procedure
For complete information on available end connections, see end connections options below. 6DB Series ball valves are furnished complete with
tube or pipe connections.
6DB 15 M9 M4 XXX
Valve Pressure Tube Vent Connection HT - High Temperature
Series (X 1000 psi) Connection M4 - SF250CX20
6DB: 3/8 Double Block M9 - SF562CX20 (see chart below)
(see chart below)
Connection Options
Catalog Tube Connection MAWP @ Hex Vent Connection Vent
Number Number Connection Room Temperature Inches(mm) Number Connection
6DB10L8P4 L8 SW500 10,000 psi (690 bar) 1.38 (35.05) P4 1/4" NPT
6DB15M12M4 M12 SF750CX20 15,000 psi (1034 bar) 1.38 (35.05) M4 SF250CX20
6DB15M9P4 M9 SF562CX20 15,000 psi (1034 bar) 1.38 (35.05) P4 1/4" NPT
6DB15M16P4 M16 SF1000CX20 15,000 psi (1034 bar) 1.75 (44.45) P4 1/4" NPT
6DB15P4P4 P4 1/4" NPT 15,000 psi (1034 bar) 1.38 (35.05) P4 1/4" NPT
6DB15P6P4 P6 3/8" NPT 15,000 psi (1034 bar) 1.38 (35.05) P4 1/4" NPT
6DB15P8P4 P8 1/2" NPT 15,000 psi (1034 bar) 1.38 (35.05) P4 1/4" NPT
2.00 2.00
(50.80) (50.80)
WARNING
FAILURE, IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS AND/OR SYSTEMS DESCRIBED HEREIN OR RELATED ITEMS CAN CAUSE DEATH, PERSONAL INJURY AND PROPERTY DAMAGE.
This document and other information from Parker Hannifin Corporation, its subsidiaries and authorized distributors provide product and/or system options for further investigation by users having technical
expertise. It is important that you analyze all aspects of your application and review the information concerning the product or system in the current product catalog. Due to the variety of operating conditions
and applications for these products or systems, the user, through its own analysis and testing, is solely responsible for making the final selection of the products and systems and assuring that all performance,
safety and warning requirements of the application are met. The products described herein, including without limitation, product features, specifications, designs, availability and pricing, are subject to change by
Parker Hannifin Corporation and its subsidiaries at any time without notice.
Offer of Sale
The items described in this document are available for sale by Parker Hannifin Corporation, its subsidiaries or its authorized distributors. Any sale contract entered by Parker will be governed by the provisions
stated in Parker's standard terms and conditions of sale (copy available upon request).
2013 Parker Hannifin Corporation | Autoclave Engineers is a registered trademark of the Parker Hannifin Corporation 02-1258SE January2013
www.autoclave.com
The Parker Autoclave Engineers ball valves can be utilized to
switch or isolate flow. The standard material of construction of
the valve is 316 cold worked stainless steel with PEEK seats,
graphite filled PTFE stem seal, and o-ring material as required
by the process fluid.
2
Ball Valves - 2-Way Subsea Series (1/4 Orifice)
Pressures to 20,000 psi (1379 bar) .250 (6.35mm) Orifice
MAWP: Maximum Allowable Working Pressure (-18) (38) (93) (150) (204) (260)
Cv listed is for maximum orifice size of .250 inches only. 20,000 (1379)
SF & F CONNECTIONS
Consult factory for Cv of valves with reduced orifice sizes.
15,000 (1034)
W125, SW250, SW375, & NPT CONNECTIONS
PRESSURE PSIG
PRESSURE BAR
ONE PIECE BALL STEM
10,000 (690)
PACKING GLAND SW500 CONNECTION
LOCKING PIECE
THRUST WASHER
O-RING
SPRING ENERGIZED SEAL
O-RING
5,000 (345)
PEEK SEATS
SEAT GLAND
Pressure ratings are determined by the end connections chosen, see chart.
O-RING
BEARING Maximum temperature rating is determined by the o-ring material
SEAT RETAINER
(see descriptions below).
BOTTOM THRUST WASHER
O-RING
LOCKING PIECE
Maximum pressure rating is determined by the end connection
BOTTOM GLAND
(see table above).
NOTE: Ball valves are not recommended for critical gas applications such as Hydrogen, Helium or other small molecular gases.
Ordering Procedure
For complete information on available end connections, see next page. 2-way ball valves are furnished complete with tube or pipe connections.
Standard valve has Buna-N o-rings [250F (121C)] max.
S2B 4 S 20 M9 XXX
Valve Ball Material Pressure End Connection Options
Series Orifice (X 1000 psi)
Subsea-2-way Diameter S - 316SS M9 - SF562CX20 V - Viton: 400F (204C) max
(See Chart on EPDM - Ethylene Propylene: 250F (121C) max
4-1/4 (For material options
contact factory) next page)
(6.35mm)
3
End Connection Options
Seat Gland
Catalog End Connection MAWP @ Hex
Number Number Connection Room Temperature Inches(mm)
S2B4S15L2 L2 W125 15,000 psi (1034 bar) 1 (25.40)
S2B4S15L4 L4 SW250 15,000 psi (1034 bar) 1 (25.40)
S2B4S15L6 L6 SW375 15,000 psi (1034 bar) 1 (25.40)
S2B4S10L8 L8 SW500 10,000 psi (690 bar) 1 (25.40)
S2B4S20M4 M4 SF250CX20 20,000 psi (1379 bar) 1 (25.40)
S2B4S20M6 M6 SF375CX20 20,000 psi (1379 bar) 1 (25.40)
S2B4S20M9 M9 SF562CX20 20,000 psi (1379 bar) 1 (25.40)
S2B4S20H4 H4 F250C 20,000 psi (1379 bar) 1 (25.40)
S2B4S20H6 H6 F375C 20,000 psi (1379 bar) 1 (25.40)
S2B4S20H9 H9 F562C 20,000 psi (1379 bar) 1.38 (35.05)
S2B4S15P2 P2 1/8 NPT 15,000 psi (1034 bar) 1 (25.40)
S2B4S15P4 P4 1/4 NPT 15,000 psi (1034 bar) 1 (25.40)
S2B4S15P6 P6 3/8 NPT 15,000 psi (1034 bar) 1 (25.40)
S2B4S15P8 P8 1/2 NPT 15,000 psi (1034 bar) 1.38 (35.05)
1.50
MAWP: Maximum Allowable Working Pressure
(38.1) 1/4-20 THD
0.75
See ball valve option/details section for end connection details, material, and high temperature options.
(19.1)
1.50
(38.1) 1/4-20 THD
0.75
(19.1)
0.50
(12.7)
0.81 HEX
0.50 1.00 (20.6)
(12.7) (25.4)
0.81 HEX
1.00 (20.6)
(25.4)
NOTE:
0.50 FLAT LG
(12.7) 0.216 0.001 FLAT 1. MAWP (See Table)
(5.48 .025)
2. Maximum Sea Depth
12,500 FT (3811 meters)
0.50 FLAT LG
(12.7)
0.249
0.216 0.001
(6.32
0.001
.025)
FLAT 3. Maximum External Pressure
(5.48 .025)
5,500 psi (379 bar)
1.27
(32.4)
0.249 0.001
(6.32 .025)
0.25
(6.4)
1.27 0.28
(32.4) (7.1)
0.25
0.43 (6.4)
0.28 (10.9)
(7.1)
4.31
1.50 0.43 (109.3)
(38.1) (10.9)
4.31
1.50 (109.3)
(38.1)
SEE END
CONNECTION
OPTIONS
(both ends)
SEE END
1.19 SEE SEAT
CONNECTION
(30.2) GLAND HEX
OPTIONS
HEX (both ends)
TEMPERATURE C
(-18) (38) (93) (150) (204) (260)
ONE PIECE BALL STEM 20,000 (1379)
O-RING SF CONNECTION
PRESSURE BAR
THRUST WASHER
5,000 (345)
BOTTOM GLAND LOCKING PIECE Pressure ratings are determined by the end connections chosen, see chart.
NOTE: Ball valves are not recommended for critical gas applications such as Hydrogen, Helium or other small molecular gases.
Ordering Procedure
For complete information on available end connections, see next page. 2-way ball valves are furnished complete with tube or pipe connections.
Standard valve has Buna-N o-rings [250F (121C)] max.
S2B 6 S 20 M9 XXX
Valve Ball Material Pressure End Connection Options
Series Orifice (X 1000 psi)
Subsea-2-way Diameter S - 316SS M9 - SF562CX20 V - Viton: 400F (204C) max
(See Chart on EPDM - Ethylene Propylene: 250F (121C) max
6-3/8 (For material options
next page)
(9.52 mm) contact factory)
5
End Connection Options
Seat Gland
Catalog End Connection MAWP @ Hex
Number Number Connection Room Temperature Inches(mm)
1.25
(31.8)
2.50
(63.5)
1.25 0.69
(31.8) (17.5)
1.38
0.88 (34.9)
(22.3) BODY
THICKNESS
0.69
(17.5)
1.38
0.88 (34.9)
(22.3) BODY
0.44 HEX THICKNESS
1.38
(11.1) 0.94 (35.1) 5/16-18 THRD
(23.9) .59 DEEP TYP
(4) PLACES
1.03 0.44
(26.2) (11.1)
1.03
(26.2)
5.78
(146.8) 0.44
(26.2)
5.78 1.78
(146.8) 0.44 (45.2)
(26.2)
1.78
(45.2)3.28
(83.3)
3.28
(83.3)
SEE END
CONNECTION
OPTIONS
(both ends)
1.75 HEX SEE END
(44.5) CONNECTION
OPTIONS
(both ends)
SEE SEAT
1.75 HEX
0.76 GLAND HEX
(44.5)
(19.2)
SEE SEAT
3.00 0.76 GLAND HEX
(76.2) (19.2)
5.53
(140.3)
3.00
(76.2)
Dimensions for reference only
6 5.53 and subject to change.
(140.3)
Ball Valves - 2-Way Subsea Series (1/2 Orifice)
Pressures to 15,000 psi (1034 bar) .500 (12.7mm) Orifice
O-RING TEMPERATURE C
PACKING GLAND
(-18) (38) (93) (150) (204) (260)
LOCKING PIECE 15,000 (1034)
THRUST WASHER SF CONNECTIONS
O-RING
SPRING
ENERGIZED PEEK SEATS
(690)
PRESSURE PSIG
10,000
PRESSURE BAR
SEAL
SEAT GLAND NPT CONNECTIONS
5,000 (345)
NOTE: Ball valves are not recommended for critical gas applications such as Hydrogen, Helium or other small molecular gases.
Ordering Procedure
For complete information on available end connections, see next page. 2-way ball valves are furnished complete with tube or pipe connections.
Standard valve has Buna-N o-rings [250F (121C)] max.
7
End Connection Options
Seat Gland
Catalog End Connection MAWP @ Hex
Number Number Connection Room Temperature Inches(mm)
S2B8S10P12 P12 3/4 NPT 10,000 psi (690 bar) 1.75 (44.5)
0.50
(12.7) 1.75
1.00 (44.5)
(25.4) BODY
THICKNESS
3.00
(76.2)
1.50 1.50
(38.1) (38.1)
1.50 1.50
(38.1) (38.1)
0.44
(11.1) 0.62
6.44 (15.9)
(163.5)
2.08
(52.8)
0.77
4.00 (19.6)
(101.6)
0.44
(11.1) SEE END
6.44 CONNECTION
(163.5) OPTIONS
2.08 (both ends)
(52.8)
SEE SEAT
4.00 GLAND HEX
(101.6)
2.25 HEX
(57.2)
SEE END
0.88 CONNECTION
(22.4) OPTIONS
(both ends)
SEE SEAT
4.13 GLAND HEX
(104.8)
7.73 2.25 HEX
(196.4) (57.2)
Dimensions for reference only
0.88 and subject to change.
(22.4)
4.13
(104.8)
7.73
(196.4)
8
Ball Valves - 2-Way Subsea Series (3/4 Orifice)
Pressures to 15,000 psi (1034 bar) .750 (19mm) Orifice
O-RING TEMPERATURE C
PACKING GLAND
(-18) (38) (93) (150) (204) (260)
LOCKING PIECE 15,000 (1034)
THRUST WASHER SF750CX, SF1000CX, 1/2 NPT
O-RING
SPRING
ENERGIZED PEEK SEATS
(690)
PRESSURE PSIG
10,000
PRESSURE BAR
SEAL
SEAT GLAND 3/4 & 1 NPT
5,000 (345)
NOTE: Ball valves are not recommended for critical gas applications such as Hydrogen, Helium or other small molecular gases.
Ordering Procedure
For complete information on available end connections, see next page. 2-way ball valves are furnished complete with tube or pipe connections.
Standard valve has Buna-N o-rings [250F (121C)] max.
9
End Connection Options
Seat Gland
Catalog End Connection MAWP @ Hex
Number Number Connection Room Temperature Inches(mm)
S2B12S10P12 P12 3/4 NPT 10,000 psi (690 bar) 1.88 (47.8)
MAWP:(88.9)
Maximum Allowable Working Pressure
3.50
See ball valve option/details section for end connection details, material, and high temperature options.
0.75
(19.05) 3.00
1.50 (76.2)
(38.10) BODY
THICKNESS
3.50
(88.9)
2.25 1.75
(57.2) (44.45)
(4) 3/8-16 TAP 0.75
(19.05) 3.00
.625 DEEP 1.50 (76.2)
(38.10) BODY
THICKNESS
2.25 1.75
(57.2) (44.45)
(4) 3/8-16 TAP
.625 DEEP
0.50
(12.70) .938
8.58 (23.81)
(217.93)
2.67
(67.9)
.980
5.31 (24.89)
(134.9)
0.50
(12.70) SEE END
8.58 CONNECTION
(217.93) OPTIONS
2.67 (both ends)
(67.9)
SEE SEAT
5.31 GLAND HEX
(134.9)
2.25 HEX
(57.2)
SEE END
0.75 CONNECTION
(19.05) OPTIONS
(both ends)
SEE SEAT
4.50 GLAND HEX
(114.30)
9.18 2.25 HEX
(233.10) (57.2)
Dimensions for reference only
0.75
(19.05)
and subject to change.
4.50
(114.30)
9.18
(233.10)
10
Ball Valves - 2-Way Subsea Series (1 Orifice)
Pressures to 10,000 psi (690 bar) 1.00 (25.4mm) Orifice
O-RING TEMPERATURE C
PACKING GLAND
(-18) (38) (93) (150) (204) (260)
THRUST WASHER
LOCKING PIECE 15,000 (1034)
O-RING
SPRING
ENERGIZED PEEK SEATS
(690)
PRESSURE PSIG
10,000
PRESSURE BAR
SEAL
SEAT GLAND SF & NPT CONNECTIONS
5,000 (345)
NOTE: Ball valves are not recommended for critical gas applications such as Hydrogen, Helium or other small molecular gases.
Ordering Procedure
For complete information on available end connections, see next page. 2-way ball valves are furnished complete with tube or pipe connections.
Standard valve has Buna-N o-rings [250F (121C)] max.
11
End Connection Options
Seat Gland
Catalog End Connection MAWP @ Hex
Number Number Connection Room Temperature Inches(mm)
S2B16S10P12 P12 3/4 NPT 10,000 psi (690 bar) 1.88 (47.75)
0.75
(19.05) 3.38
1.50 (85.7)
(38.10) BODY
THICKNESS
4.00
(101.6)
2.88 2.00
(73.0) (50.8)
(4) 3/8-16 TAP 0.75
.625 DEEP (19.05) 3.38
1.50 (85.7)
(38.10) BODY
THICKNESS
2.88 2.00
(73.0) (50.8)
(4) 3/8-16 TAP
.625 DEEP
0.50
(12.70) 1.25
9.96 (31.7)
(253.0)
2.67
(67.9)
1.25
5.80 (31.8)
(147.2)
0.50
(12.70) SEE END
9.96 CONNECTION
(253.0) OPTIONS
2.67 (both ends)
(67.9)
SEE SEAT
5.80 GLAND HEX
(147.2) 2.88 DIA
(73.0)
SEE END
0.98 CONNECTION
(24.9) OPTIONS
(both ends)
5.19 Dimensions
SEEfor reference only
SEAT
GLAND HEX
(131.8)
2.88 DIA and subject to change.
8.41
(213.7) (73.0)
0.98
Dimensions
(24.9)
for P12 and P16 connections only. Contact facotry for M16 dimensions.
5.19
(131.8)
8.41
(213.7)
12
Ball Valves - 3-Way Subsea Series (3/16 Orifice)
Pressures to 20,000 psi (1379 bar) .187 (4.77mm) Orifice
TEMPERATURE C
(-18) (38) (93) (150) (204) (260)
ONE PIECE BALL STEM 20,000 (1379)
SF & F CONNECTIONS
PACKING GLAND
LOCKING PIECE 15,000 (1034)
NPT CONNECTION
PRESSURE PSIG
PRESSURE BAR
O-RING
5,000 (345)
NOTE: Ball valves are not recommended for critical gas applications such as Hydrogen, Helium or other small molecular gases.
Ordering Procedure
For complete information on available end connections, see next page. 3-way ball valves are furnished complete with tube or pipe connections.
Standard valve has Buna-N o-rings [250F (121C)] max.
S3BD 3 S 20 M9 XXX
Valve Ball Material Pressure End Connection Options
Series Orifice (X 1000 psi)
S3B Subsea-3-way Diameter S -316SS M9 - SF562CX20 V - Viton: 400F (204C) max
S3BD Subsea-3-way (For material options (See Chart on EPDM - Ethylene Propylene: 250F (121C) max
diverter 3-3/16
contact factory) next page)
(4.77 mm)
13
End Connection Options
Seat Gland
Catalog End Connection MAWP @ Hex
Number Number Connection Room Temperature Inches(mm)
S3B3S15M4 M4 SF250CX20 15,000 psi (1034 bar) 1 (25.40)
S3BD3S20M4 20,000 psi (1379 bar)
S3B3S15M6 M6 SF375CX20 15,000 psi (1034 bar) 1 (25.40)
S3BD3S20M6 20,000 psi (1379 bar)
S3B3S15M9 M9 SF562CX20 15,000 psi (1034 bar) 1 (25.40)
S3BD3S20M9 20,000 psi (1379 bar)
S3B3S15H4 H4 F250C 15,000 psi (1034 bar) 1 (25.40)
S3BD3S20H4 20,000 psi (1379 bar)
S3B3S15H6 H6 F375C 15,000 psi (1034 bar) 1 (25.40)
S3BD3S20H6 20,000 psi (1379 bar)
S3B3S15P4 P4 1/4 NPT 15,000 psi (1034 bar) 1 (25.40)
S3BD3S15P4
S3B3S15P6 P6 3/8 NPT 15,000 psi (1034 bar) 1 (25.40)
S3BD3S15P6
See ball valve option/detail section for end connection details, material, and high temperature options.
OPEN OPEN OPEN CLOSED OPEN
*3-Way
*3-WayDiverter
DiverterValve
Valve 3-WayBall
3-Way Ball Valve
Valve
90
90Turn
1/4-20 TAP
Turn
.41 DEEP
2.50
(63.50) 180 Turn
180 Turn
(2) PLACES
*The Diverter Valve design permits inlet flow through the bottom port. Outlet
(31.75) flow may be diverted to either valve side port.
1.25
1.00
THK
0.25 STEM REF BODY
(6.35) (25.4)
0.50
(12.7)
0.216 .001
(5.49 .025)
2.50
(63.50)
2.50
(63.50)
4.72
(119.89)
Ball Valves - 3-Way Subsea Series (3/8 Orifice)
Pressures to 10,000 psi (689 bar) .328 (8.33mm) Orifice
BELLEVILLE WASHERS
THRUST WASHER
(690)
PRESSURE BAR
PRESSURE PSIG
5,000 (345)
NOTE: Ball valves are not recommended for critical gas applications such as Hydrogen, Helium or other small molecular gases.
Ordering Procedure
For complete information on available end connections, see next page. 3-way ball valves are furnished complete with tube or pipe connections.
Standard valve has Buna-N o-rings [250F (121C)] max.
S3B 6 S 10 M9 XXX
Valve Ball Material Pressure End Connection Options
Series Orifice (X 1000 psi)
S3B Subsea-3-way Diameter S -316SS M9 - SF562CX20 V - Viton: 400F (204C) max
S3BD Subsea-3-way (See Chart on EPDM - Ethylene Propylene: 250F (121C) max
diverter 6-3/8 (For material options
next page)
(9.52 mm) contact factory)
15
End Connection Options
Seat Gland
Catalog End Connection MAWP @ Hex
Number Number Connection Room Temperature Inches(mm)
S3B6S10L8 L8 SW500 10,000 psi (690 bar) 1.38 (35.05)
S3BD6S10L8
S3B6S10M6 M6 SF375CX20 10,000 psi (690 bar) 1.38 (35.05)
S3BD6S10M6
S3B6S10M9 M9 SF562CX20 10,000 psi (690 bar) 1.38 (35.05)
S3BD6S10M9
S3B6S10M12 M12 SF750CX20
1.38 10,000 psi (690 bar) 1.38 (35.05)
S3BD6S10M12 (35.1)
See ball valve option/details section for end connection details, material, and high temperature options.
OPEN OPEN OPEN CLOSED OPEN
*3-Way Diverter
*3-Way Diverter Valve 5.08
Valve(129.0) 3-WayBall
3-Way BallValve
Valve
90 Turn (25.4)
1.00
180Turn
Turn
90 Turn 180
*The Diverter Valve design permits inlet flow through the bottom port. Outlet flow may be diverted to either valve side port.
5.08 0.69
(129.0) (17.5)
1.00
(25.4) 1.38
(35.1)
0.69
(17.5)
1.38
1/4-20 THREAD 0.281 FLATS REF. (35.1)
(2) PLACES (7.1)
5.74
(145.8)
0.281 0.001
NOTE:
0.81
FLAT LENGTH
2 FLATS 180 APART
(7.14 .025)
1. MAWP (See Table)
.66
(16.8) .44
(20.6)
2. Maximum Sea Depth
(11.2)
2.06 0.437 0.001
11,500 FT (3505 meters)
(52.3) (11.1 .025)
B 0.281 0.001
3. Maximum External Pressure
2.00
(50.8) 0.81
FLAT LENGTH
2 FLATS 180 APART
(7.14 .025)
5,000 psi (345 bar)
1.00 (20.6)
(25.4)
0.28 HOLE
DETAIL B 2.06 0.437 0.001(2) PLACES
(52.3) (11.1 .025)(7.1)
2.00 B
0.41 TYP (50.8)
(10.4)
1.00
(25.4)
0.28 HOLE
1.63 (2) PLACES
(41.4) (7.1)
0.41 TYP
(10.4)
5.08
(129.0)
1.00 3.03
(25.4) (77.0) 1.63
(41.4)
SEE END
0.69 CONNECTION
(17.5) OPTIONS
(3 PLACES)
1.38 3.03
(35.1) (77.0)
1.75 HEX
(44.5) SEE SEAT
GLAND HEX SEE END
CONNECTION
OPTIONS
(3 PLACES)
16 3.00
(76.2)
1.28
(32.5)
PRESSURE BAR
PRESSURE PSIG
10,000
LOCKNUT SEAT GLAND
NPT & SF CONNECTIONS
5,000 (345)
Note: Side inlet pressure not recommended. Bottom inlet pressure only.
NOTE: Ball valves are not recommended for critical gas applications such as Hydrogen, Helium or other small molecular gases.
Ordering Procedure
For complete information on available end connections, see next page. 3-way ball valves are furnished complete with tube or pipe connections.
Standard valve has Buna-N o-rings [250F (121C)] max.
See ball valve options for end connection details, material, and high temperature options.
.65
OPEN OPEN (16.5) .44 OPEN CLOSED OPEN
(11.2)
1/4-20 THREAD
(2) PLACES
3.00
1.50 (76.2)
(38.1)
0.88
(22.4)
1.75
(44.5)
3.62
(91.9) SEE END
0.88
(22.4) CONNECTION
OPTIONS
1.75 (3 PLACES)
(44.5)
SEE SEAT
2.25 HEX GLAND HEX
(57.2)
1.188
(30.2) 4.13
FLAT LENGTH (104.9)
18
2.32
(58.9)
B
0.686
(17.4)
3.00
(76.2)
1.50
This page is blank
19
WARNING
FAILURE, IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS AND/OR SYSTEMS DESCRIBED HEREIN OR RELATED ITEMS CAN CAUSE DEATH, PERSONAL INJURY
AND PROPERTY DAMAGE.
This document and other information from Parker Hannifin Corporation, its subsidiaries and authorized distributors provide product and/or system options for further investiga-
tion by users having technical expertise. It is important that you analyze all aspects of your application and review the information concerning the product or system in the current
product catalog. Due to the variety of operating conditions and applications for these products or systems, the user, through its own analysis and testing, is solely responsible
for making the final selection of the products and systems and assuring that all performance, safety and warning requirements of the application are met. The products described
herein, including without limitation, product features, specifications, designs, availability and pricing, are subject to change by Parker Hannifin Corporation and its subsidiaries at
any time without notice.
Offer of Sale
The items described in this document are available for sale by Parker Hannifin Corporation, its subsidiaries or its authorized distributors. Any sale contract entered by Parker will be
governed by the provisions stated in Parker's standard terms and conditions of sale (copy available upon request).
2013 Parker Hannifin Corporation | Autoclave Engineers is a registered trademark of the Parker Hannifin Corporation 02-0108SE January2013
Instrumentation Products Division Parker Hannifin Manufacturing Ltd. Caution! Parker Autoclave Engineers Valves, Fittings and Tools are
Autoclave Engineers Operation Instrumentation Products Division, Europe not designed to work with common commercial instrument tubing
8325 Hessinger Drive Industrial Estate Whitemill and will only work with tubing built to Parker Autoclave Engineers
AES Specifications. Failure to do so will void warranty.
Erie, Pennsylvania 16509-4679 USA Wexford, Republic of Ireland
PH: 814-860-5700 FAX: 814-860-5811 PH: 353 53 914 1566
www.autoclave.com FAX: 353 53 914 1582 ISO-9001 Certified
Ball Valves
Actuators
Pneumatic Actuators
Electric Actuators
All general terms and conditions of sale, including limitations of our liability, apply to all products andwww.autoclave.com
services sold. 1
Ball Valves - Actuators
Pneumatic Operated Ball Valves
Add the suffix -AO, -AC or -AOC to the appropriate valve catalog number for a complete valve assembly
A B C D E F G H I J
2B4-AO/AC 6.69 2.56 2.50 1.25 1.00 0.50 0.28 1.14 2.50 1.58 80 psi
(169.92) (65.02) (63.50) (31.75) (25.40) (12.70) (7.11) (28.95) (63.50) (40.13) (5.51 bar)
2B6-AO/AC 9.84 3.94 3.00 1.50 1.50 0.75 0.34 1.87 3.00 2.24 80 psi
(249.93) (100.07) (76.20) (38.10) (25.40) (19.05) (8.63) (47.49) (76.20_) (56.89) (5.51 bar)
2B8-AO/AC 11.65 4.57 3.00 1.50 2.00 1.00 0.53 2.17 3.00 2.48 80 psi
*
3BD3-AO/AC
(259.91) (116.07) (76.20)
6.69 2.56 2.50
(38.10)
1.25
(50.80)
1.00
(25.40) (13.46)
0.50 0.28
(55.11)
1.14
(76.20)
2.50
(62.99)
1.58
(5.51 bar)
80 psi
(169.92) (65.02) (63.50) (31.75) (25.40) (12.70) (7.11) (28.95) (63.50) (40.13) (5.51 bar)
3BD6-AO/AC 9.84 3.94 3.00 1.50 1.50 0.75 0.34 1.87 3.00 2.24 80 psi
*
3BD8-AO/AC
(249.93) (100.07) (76.20)
11.65 4.57 3.00
(38.10)
1.50
(25.40)
2.00
(19.05)
1.00
(8.63)
0.53
(47.49) (76.20_) (56.89)
2.17 3.00 2.48
(5.51 bar)
80 psi
(259.91) (116.07) (76.20) (38.10) (50.80) (25.40) (13.46) (55.11) (76.20) (62.99) (5.51 bar)
2B4-AOC 6.69 2.56 2.50 1.25 1.00 0.50 0.28 1.14 2.50 1.58 80 psi
(169.92) (65.02) (63.50) (31.75) (25.40) (12.70) (7.11) (28.95) (63.50) (40.13) (5.51 bar)
2B6-AOC 7.95 3.07 3.00 1.50 1.50 0.75 0.34 1.40 3.00 1.77 80 psi
(201.93) (77.97) (76.20) (38.10) (38.10) (19.05) (8.63) (35.56) (76.20_) (44.95) (5.51 bar)
2B8-AOC 9.84 3.94 3.00 1.50 2.00 1.00 0.53 1.87 3.00 2.24 80 psi
(249.91) (100.07) (76.20) (38.10) (50.80) (25.40) (13.46) (47.49) (76.20) (56.89) (5.51 bar)
3BD3-AOC 6.69 2.56 2.50 1.25 1.00 0.50 0.28 1.14 2.50 1.58 80 psi
(169.92) (65.02) (63.50) (31.75) (25.40) (12.70) (7.11) (28.95) (63.50) (40.13) (5.51 bar)
3BD6-AOC 7.95 3.07 3.00 1.50 1.50 0.75 0.34 1.40 3.00 1.77 80 psi
(201.93) (77.97) (76.20) (38.10) (25.40) (19.05) (8.63) (35.56) (76.20_) (44.95) (5.51 bar)
3BD8-AOC 9.84 3.94 3.00 1.50 2.00 1.00 0.53 1.87 3.00 2.24 80 psi
(249.91) (100.07) (76.20) (38.10) (50.80) (25.40) (13.46) (47.49) (76.20) (56.89) (5.51 bar)
NOTE: Maximum allowable air pressure is 150 psi (10.34) Actuators operating temperature: 0F to 175F (-17C to 79C)
1/8 NPT female air connector (*= 1/4 NPT) High temperature actuator option available, consult factory
AO: Air to open/spring to close Stainless steel housing actuator models available, consult factory
AC: Air to close/spring to open Actuators available with limit switches and visual indicators.
AOC: Air to open/air to close (double acting) Corrosion resistant anodized aluminum housing.
Epoxy coated housing available.
Solenoids availabe, direct or nipple mount.
"A" "J" "H"
"A"/2
"B"
"G" DIAMETER
(2) Holes
"C" "F"
"D" "E"
2 All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold.
Ball Valves - Actuators
Electric Operated Ball Valves
Add the suffix -EO1, -EO2 or -EO3 to the appropriate valve catalog number for a complete valve assembly
SERIES
A B C D E F
2B4-EO1 2.50 1.25 1.00 0.50 0.28 2.50 120 VAC
50/60 Hz
2B4-EO2 (63.50) (31.75) (25.40) (12.70) (7.11) (63.50) 240 VAC
2B6-EO1 3.00 1.50 1.50 0.75 0.34 3.00 120 VAC
50/60 Hz
2B6-EO2 (76.20) (38.10) (38.10) (19.05) (8.63) (76.20) 240 VAC
3BD3-EO1 2.50 1.25 1.00 0.50 0.28 2.50 120 VAC 50/60 Hz
3BD3-EO2 (63.50) (31.75) (25.40) (12.70) (7.11) (63.50) 240 VAC
3BD6-EO1 3.00 1.50 1.50 0.75 0.34 3.00 120 VAC
50/60 Hz
3BD6-EO2 (76.20) (38.10) (38.10) (19.05) (8.63) (76.20) 240 VAC
2B4-EO3 2.50 1.25 1.00 0.50 0.28 2.50 24 VDC
(63.50) (31.75) (25.40) (12.70) (7.11) (63.50)
2B6-EO3 3.00 1.50 1.50 0.75 0.34 3.00 24 VDC
(76.20) (38.10) (38.10) (19.05) (8.63) (76.20)
3BD3-EO3 2.50 1.25 1.00 0.50 0.28 2.50 24 VDC
(63.50) (31.75) (25.40) (12.70) (7.11) (63.50)
3BD6-EO3 3.00 1.50 1.50 0.75 0.34 3.00 24 VDC
(76.20) (38.10) (38.10) (19.05) (8.63) (76.20)
NOTE: EO1: Electric 120 VAC For other voltages consult factory
EO2: Electric 220 VAC Actuator operating temperature: 0F to 160F (-17C to 71C)
EO3: Electric 24 VDC Corrosive resistant Zytel housing
CSA approved for NEMA 4 & 4X Consult factory for epoxy option
* *
*
*
* *
*
"E" DIAMETER
(2) Holes
*
"A"
"D"
"C"
"B"
NOTE:
Operators 90 rotations standard.
180 options available upon request.
"F/2"
"F"
All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold. 3
Ball Valves - Actuators
Electric Operated Ball Valves
Add the suffix -EO1, -EO2 or -EO3 to the appropriate valve catalog number for a complete valve assembly
* * *
*
*
*
*
* *
* *
0.53 (13.46)
3.00 (2) HOLES
(76.20)
1.50 1.00 (25.40)
(38.10) 2.00 (50.80) NOTE:
* Contact factory for dimensions
1.50
3.00 (38.10)
(76.20)
WARNING
FAILURE, IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS AND/OR SYSTEMS DESCRIBED HEREIN OR RELATED ITEMS CAN CAUSE DEATH, PERSONAL INJURY
AND PROPERTY DAMAGE.
This document and other information from Parker Hannifin Corporation, its subsidiaries and authorized distributors provide product and/or system options for further investiga-
tion by users having technical expertise. It is important that you analyze all aspects of your application and review the information concerning the product or system in the current
product catalog. Due to the variety of operating conditions and applications for these products or systems, the user, through its own analysis and testing, is solely responsible
for making the final selection of the products and systems and assuring that all performance, safety and warning requirements of the application are met. The products described
herein, including without limitation, product features, specifications, designs, availability and pricing, are subject to change by Parker Hannifin Corporation and its subsidiaries at
any time without notice.
Offer of Sale
The items described in this document are available for sale by Parker Hannifin Corporation, its subsidiaries or its authorized distributors. Any sale contract entered by Parker will be
governed by the provisions stated in Parker's standard terms and conditions of sale (copy available upon request).
2013 Parker Hannifin Corporation | Autoclave Engineers is a registered trademark of the Parker Hannifin Corporation 02-0109SE January2013
Instrumentation Products Division Parker Hannifin Manufacturing Ltd. Caution! Parker Autoclave Engineers Valves, Fittings and Tools are
Autoclave Engineers Operation Instrumentation Products Division, Europe not designed to work with common commercial instrument tubing
8325 Hessinger Drive Industrial Estate Whitemill and will only work with tubing built to Parker Autoclave Engineers
Erie, Pennsylvania 16509-4679 USA Wexford, Republic of Ireland AES Specifications. Failure to do so will void warranty.
All general terms and conditions of sale, including limitations of our liability, apply to all products andwww.autoclave.com
services sold. 1
Ball Valves - Options / Details
High temperature pneumatic valve actuators are also available. Consult factory with your application
and for specific information.
Material Options
Standard ball valves are constructed of 316 stainless steel. Other materials are available for specific
applications upon request. NACE (MR0175-2002) approved materials for sour service can be supplied
upon request. Consult factory for later NACE revisions and for the materials available as well as the
temperature and pressure ratings.
Handle Lockouts
Handle lockouts are available to lockout ball valves in the open or closed position preventing
unauthorized personnel from actuating valves during shutdowns or emergency situations.
Note: To purchase ball valves with lockouts add -L to part number.
Part numbers to purchase lockout separately:
2-Way Ball Valves 3-Way Ball Valves
1/4" 2B4-L 3/16" 3B3-L
3/8" 2B6-L 3/8" 3B6-L
1/2" 2B8-L 1/2" 3B8-L
For 3-way switching ball valves, consult factory.
For 6DB (double block and bleed) valves use two 2B6-L lockouts.
2 All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold.
Tube Connection Dimensions - AE SpeedBite SW *
Tube
Outside Dimensions - Inches (mm) 24
Diameter Connection B
THREAD
inches Type A
DRILL
(mm) A B C D E F G F
C
1/4 SW250 29/64 1/2 -20 0.34 0.44 0.69 0.35 F 0.257 G D
20
3/8 SW375 37/64 5/8 -18 0.38 0.47 0.75 0.48 W 0.386
(19.50) (14.70) (15.90) -18 (9.65) (11.90) (19.10) (12.20) W (9.80)
1/2 SW500 3/4 13/16 -16 0.41 0.50 0.81 0.60 0.514 *
(12.70) (19.10) (20.60) -16 (10.50) (12.70) (20.60) (15.20) (13.100)
Tube
Dimensions - Inches (mm)
24
Outside
Diameter Connection B
THREAD
inches Type A
DRILL
(mm) A B C D E F G F
C
1/8 W125 Q 0.332 3/8 -24 0.22 0.31 0.47 0.19 #30 0.128 G D
(3.18) Q (8.43) (9.53) -24 (5.59) (7.87) (11.90) (4.83) #30 (3.25) E
20
1/4 W250 11/16 3/4 -16 0.38 0.44 0.69 0.35 F 0.257
(6.35) (17.50) (19.10) -16 (9.65) (11.20) (17.50) (8.89) F (6.53)
3/8 W375 11/16 3/4 -16 0.38 0.44 0.69 0.48 W 0.386 *
(9.53) (17.50) (19.10) -16 (9.65) (11.20) (17.50) (12.20) W (9.80)
Tube
Outside Dimensions - Inches (mm) 60
Diameter Connection
inches Type
(mm) A B C D F B
THREAD
1/4 SF250CX20 25/64 7/16 -20 0.28 0.50 0.19 A
(6.35) (9.92) (11.10) -20 (7.11) (12.70) (4.83) DRILL
F
3/8 SF375CX20 33/64 9/16 -18 0.38 0.62 0.31
(9.53) (13.10) (14.30) -18 (9.65) (15.70) (7.87) C
D
9/16 SF562CX20 3/4 13/16 -16 0.44 0.75 0.50
(14.30) (19.10) (20.60) -16 (11.20) (19.10) (12.70)
All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold. 3
Tube Connection Dimensions - AE HighPressure FC **
Tube
Outside Dimensions - Inches (mm) 60
Diameter Connection
inches Type B
THREAD
(mm) A B C D F A
DRILL
F
1/4 F250C 33/64 9/16 -18 0.38 0.44 0.17
(6.35) (13.10) (14.30) -18 (9.65) (11.20) (4.32) 5 C D
WARNING
FAILURE, IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS AND/OR SYSTEMS DESCRIBED HEREIN OR RELATED ITEMS CAN CAUSE DEATH, PERSONAL INJURY
AND PROPERTY DAMAGE.
This document and other information from Parker Hannifin Corporation, its subsidiaries and authorized distributors provide product and/or system options for further investiga-
tion by users having technical expertise. It is important that you analyze all aspects of your application and review the information concerning the product or system in the current
product catalog. Due to the variety of operating conditions and applications for these products or systems, the user, through its own analysis and testing, is solely responsible
for making the final selection of the products and systems and assuring that all performance, safety and warning requirements of the application are met. The products described
herein, including without limitation, product features, specifications, designs, availability and pricing, are subject to change by Parker Hannifin Corporation and its subsidiaries at
any time without notice.
Offer of Sale
The items described in this document are available for sale by Parker Hannifin Corporation, its subsidiaries or its authorized distributors. Any sale contract entered by Parker will be
governed by the provisions stated in Parker's standard terms and conditions of sale (copy available upon request).
2013 Parker Hannifin Corporation | Autoclave Engineers is a registered trademark of the Parker Hannifin Corporation 02-0110SE January2013
Instrumentation Products Division Parker Hannifin Manufacturing Ltd. Caution! Parker Autoclave Engineers Valves, Fittings and Tools are
Autoclave Engineers Operation Instrumentation Products Division, Europe not designed to work with common commercial instrument tubing
8325 Hessinger Drive Industrial Estate Whitemill and will only work with tubing built to Parker Autoclave Engineers
AES Specifications. Failure to do so will void warranty.
Erie, Pennsylvania 16509-4679 USA Wexford, Republic of Ireland
PH: 814-860-5700 FAX: 814-860-5811 PH: 353 53 914 1566
4www.autoclave.com All general terms andFAX: 353 53 of
conditions 914sale,
1582including limitations of our liability, apply to all products and services sold. ISO-9001 Certified
Relief Valve
Pressures to 75,000 psi ( 5171 bar)
RVP Metal Seat Relief Valves
Series RVP relief valves provide reliable venting of
gases or liquids for set pressures from 3,000 psi
(206.8 bar) minimum to 75,000 psi (5171 bar). The
standard temperature range for all models is -423 to
400 (-252 to 204C). A high temperature option to
750F (399C) is also available.
The soft seat design provides bubble tight sealing, repeatable pop-off, and reseat. Additionally,
soft seat valves provide a higher cycle life than metal seat relief valves.
These precision valves are designed for pressure gas systems, where zero leakage is critical. They
are not recommended for liquid nitrogen or liquid carbon dioxide, which produce gas at cryogenic
temperatures upon relief.
Relief valves are designed to open proportionally to increasing pressure. Therefore, they are not
recommended for applications requiring immediate full valve flow at set pressure (such as
decompositions, polymerizations, etc.). Full flow of relief valve is defined at 10% over
set pressure.
Relief Valve
www.autoclave.com
AE Relief Valves Features
Materials: Standard models of Relief Valves are constructed of 316 stainless steel with selected compo-
nents made of anti-galling stainless steel material for optimum economy and ruggedness.
Connections: All models except 30, 60, & 75 RVP series are designed with 9/16 Parker Autoclave Engi-
neers Medium Pressure inlet connections. The 30 & 60 RVP have 3/8 high pressure connection, while the
75 RVP has a 5/16 high pressure connections. The outlet connection on all models is a female 3/4 NPT.
While adapters to other sizes and connection types are available, they must be sized for specific flow re-
quirements. See Adapter section.
Orifice Sizes: Orifice diameters range from .062 (1.57mm) to .312 (7.92mm).
Full Lift for Full Flow: These relief valves are designed to open as a function of increasing system
pressure. Proper spring selection assures repeatability of opening, full lift and flow, and reseat pressures.
Reliability and Long Service Life: Materials engineering and stringent quality control procedures combine
to assure the highest quality, reliability and service life. Each valve is preset and factory sealed to ensure
proper valve operation.
High Set Pressure Capability: Unique seat construction plus over-the-nozzle guiding and proper selection of
materials permits standard set pressures to 75,000 psi. (5171 bar)
Dependable Shut-off: Series RVP relief valves are designed to provide shut-off of liquids and gases under
pressure to commercial tightness standards. Series RVS relief valves are designed to provide bubble tight
shut off of gases.
Fewer Parts, Ease of Maintenance: Engineered to perform with fewer basic components, both RVP and
RVS valves facilitate minimum stocking of spare parts and ease of maintenance. The combined angle seat in
the RVP series eliminates the need for lapping in rework.
Special Requirements: Most models available with CE Mark. SOG option available upon request.
2 All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold.
Relief Valves - RVP Metal Seat Relief Valves
15 RVP set
pressure range Lock Nut
10,000 Gasket
(690)
10 RVP
10 RVP set Spindle
pressure range Spring Washer
5,000 Spring
(344)
5 RVP 5 RVP set
pressure range Spring
Cylinder
0 A
1,000 Lock Nut Mounting Holes
2,000 3,000 4,000
.28 (7.11mm)
(28.32) (56.64) (84.96) (113.28)
SCFM (SCMM) @ 10% overpressure 316SS Plug
5RVP9072 SF562CX 3/4 0.312 (7.92) 3,000 (206.84) 5,000 (344.73) 500 (34.47) 9.40 (238.76)
10RVP9072 SF562CX 3/4 0.250 (6.35) 5,000 (344.73) 10,000 (689.46) 500 (34.47) 9.40 (238.76)
15RVP9072 SF562CX 3/4 0.188 (4.78) 10,000 (689.46) 15,000 (1034.20) 500 (34.47) 9.40 (238.76)
20RVP9072 SF562CX 3/4 0.156 (3.96) 15,000 (1034.20) 20,000 (1378.93) 500 (34.47) 9.40 (238.76)
30RVP6072 F375C 3/4 0.125 (3.18) 20,000 (1378.93) 30,000 (2068.39) 500 (34.47) 9.52 (241.81)
45RVP9072 F562C 3/4 0.093 (2.36) 25,000 (1723.66) 45,000 (3102.59) 500 (34.47) 9.52 (241.81)
60RVP6072 F375C 3/4 0.078 (1.98) 30,000 (2068.39) 60,000 (4136.79) 500 (34.47) 9.52 (241.81)
75RVP5072 F312C150 3/4 0.062 (1.57) 37,000 (2551.02) 75,000 (5170.99) 500 (34.47) 9.83 (249.68)
*Maximum pressure rating is based on the lowest rating of any For prompt service, Parker Autoclave Engineers stocks select
component. Actual working pressure may be determined by products. Consult factory.
tubing pressure rating, if lower.
All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold. 3
Ordering Table and Specifications
Caution: A
Mounting Holes
1. AE relief valves are preset and factory sealed. Lock Nut
.28 (7.11mm)
5RVS9072 SF562CX 3/4 0.312 (7.92) 1,500 (103.42) 5,000 (344.73) 500 (34.47) 9.40 (238.76)
10RVS9072 SF562CX 3/4 0.25 (6.35) 5,000 (344.73) 10,000 (689.46) 500 (34.47) 9.40 (238.76)
20RVS9072 SF562CX 3/4 0.156 (3.96) 10,000 (689.46) 20,000 (1378.93) 500 (34.47) 9.40 (238.76)
*Maximum pressure rating is based on the lowest rating of any component. Actual working pressure may be determined by tubing pressure rating, if lower. For prompt service, Parker Autoclave
Note: For pressure rating see selection chart. Engineers stocks select products.
Consult factory.
WARNING
FAILURE, IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS AND/OR SYSTEMS DESCRIBED HEREIN OR RELATED ITEMS CAN CAUSE DEATH, PERSONAL INJURY AND PROPERTY DAMAGE.
This document and other information from Parker Hannifin Corporation, its subsidiaries and authorized distributors provide product and/or system options for further investigation by users having technical
expertise. It is important that you analyze all aspects of your application and review the information concerning the product or system in the current product catalog. Due to the variety of operating conditions
and applications for these products or systems, the user, through its own analysis and testing, is solely responsible for making the final selection of the products and systems and assuring that all performance,
safety and warning requirements of the application are met. The products described herein, including without limitation, product features, specifications, designs, availability and pricing, are subject to change by
Parker Hannifin Corporation and its subsidiaries at any time without notice.
Offer of Sale
The items described in this document are available for sale by Parker Hannifin Corporation, its subsidiaries or its authorized distributors. Any sale contract entered by Parker will be governed by the provisions
stated in Parker's standard terms and conditions of sale (copy available upon request).
2013 Parker Hannifin Corporation | Autoclave Engineers is a registered trademark of the Parker Hannifin Corporation 02-0129SE January2013
Instrumentation Products Division Parker Hannifin Manufacturing Ltd. Caution! Parker Autoclave Engineers Valves, Fittings and Tools are
not designed to work with common commercial instrument tubing
Autoclave Engineers Operation Instrumentation Products Division, Europe
and will only work with tubing built to Parker Autoclave Engineers
8325 Hessinger Drive Industrial Estate Whitemill
AES Specifications. Failure to do so will void warranty.
Erie, Pennsylvania 16509-4679 USA Wexford, Republic of Ireland
PH: 814-860-5700 FAX: 814-860-5811 PH: 353 53 914 1566
www.autoclave.com FAX: 353 53 914 1582 ISO-9001 Certified
Custom
Valves, Adapters
& Manifolds
Parker Autoclave Engineers offers special
components designed to meet customer specific
requirements.
www.autoclave.com
Custom Valves, Adapters & Manifolds
Special Adapters
Parker Autoclave Engineers also offers a line of compo- AE Medium Pressure (Male)
nents that assist in adapting into and out of specialized
connections with Parker Autoclave Engineers medium
pressure products. Along with the adapters shown, Parker
Autoclave Engineers can provide other special adapters to
fill requirements. Contact your local sales representative
for information. KC105 - 2 Piece
KC105 - 1 Piece
Dielectric Fittings
Dielectric couplings isolate components from the effects of
electrical current. Available as male/female coupling rated
to 15,000 psi (1034 bar) with selected connection sizes.
For more information contact local sales or the factory
2 All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold.
Custom Valves, Adapters & Manifolds
Metric, Special Material & Special Configuration Valves, Fittings & Tubing
Parker Autoclave Engineers medium and high pressure
valves and fittings are available in a variety of special ma-
terials and configurations to satisfy most process require-
ments. Please refer to the Valve Options section for types
of materials available and ordering information.
Other custom valves available include large port valves for
ammonia, urea and polyethylene production service, and
Y style straight-thru valves designed to minimize pressure
drop.
Contact your local sales representative to find out more
about these custom products. See the metric section in
this catalog for our complete line of metric valves, fitting
and tubing line.
Manifold Block
Specialty pressure manifolds minimize space requirements
and reduce the installation time necessary to plumb a
pressure system. In addition, by reducing the number of
components used in a system, manifolds also reduce the
number of potential leak joints. Parker Autoclave Engineers
will design and build pressure manifolds to meet specific
installation, layout, and pressure requirements. These mani-
folds are capable of withstanding pressures from vacuum to
100,000 psi (6895 bar), and are available in a variety of ma-
terials and sizes. Among the pressure connections that can
be incorporated are Parker Autoclave Engineers low, medium
and high pressure, NPT, SAE, BSP and others. Transitions in
system line sizes and tubing pressure can be accomplished
through a specialty manifold. These manifolds are appropri-
ate wherever pressure tubing systems are utilized.
All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold. 3
WARNING
FAILURE, IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS AND/OR SYSTEMS DESCRIBED HEREIN OR RELATED ITEMS CAN CAUSE DEATH, PERSONAL INJURY AND PROPERTY DAMAGE.
This document and other information from Parker Hannifin Corporation, its subsidiaries and authorized distributors provide product and/or system options for further investigation by users having technical
expertise. It is important that you analyze all aspects of your application and review the information concerning the product or system in the current product catalog. Due to the variety of operating conditions
and applications for these products or systems, the user, through its own analysis and testing, is solely responsible for making the final selection of the products and systems and assuring that all performance,
safety and warning requirements of the application are met. The products described herein, including without limitation, product features, specifications, designs, availability and pricing, are subject to change by
Parker Hannifin Corporation and its subsidiaries at any time without notice.
Offer of Sale
The items described in this document are available for sale by Parker Hannifin Corporation, its subsidiaries or its authorized distributors. Any sale contract entered by Parker will be governed by the provisions
stated in Parker's standard terms and conditions of sale (copy available upon request).
2013 Parker Hannifin Corporation | Autoclave Engineers is a registered trademark of the Parker Hannifin Corporation 02-0131SE January2013
Instrumentation Products Division Parker Hannifin Manufacturing Ltd. Caution! Parker Autoclave Engineers Valves, Fittings and Tools are
Autoclave Engineers Operation Instrumentation Products Division, Europe not designed to work with common commercial instrument tubing
and will only work with tubing built to Parker Autoclave Engineers
8325 Hessinger Drive Industrial Estate Whitemill
AES Specifications. Failure to do so will void warranty.
Erie, Pennsylvania 16509-4679 USA Wexford, Republic of Ireland
PH: 814-860-5700 FAX: 814-860-5811 PH: 353 53 914 1566
www.autoclave.com FAX: 353 53 914 1582 ISO-9001 Certified
Accessories
Parker Autoclave Engineers offers a complete selection of
accessories to complete your system requirements.
Accessories
www.autoclave.com
Accessories - Pencil-type Thermocouples
Pressures to 15,000 psi (1034 bar)
Materials
Precision-molded plastic connectors have heavy duty, spring-
loaded jack inserts for positive contact. The sheath is type 316
stainless steel with 316 SS ferrule and gland. We offer a choice
of iron constantan (J) or chromel-alumel (K) type elements
(please specify when ordering). Basic assembly includes 1/8
Parker Autoclave Engineers Speedbite connection with adapt-
ers for other connection sizes.
Pressure/Temperature Ratings
Ratings to 15,000 psi (1034 bar) maximum working pressure.
Temperature rating based on connection style. Low pressure
Speedbite connection not recommended below 0F (-17.8C)
or above 650F (343C)
Ordering Information
Catalog order numbers in the table refer to the complete as-
sembly. Add suffixJ for iron constantan element or K for
chromel-alumel. To order a basic thermocouple with plug/jack
assembly and connection (without through or angle block),
change last digit in order number to 0 and specify sheath
length if different from standard 3.62 (91.94 mm) length.
2 All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold.
Accessories - Pencil-type Thermocouples
Fits Tubing Dimensions - inches (mm)
Catalog Connection Size Block Fitting
Number Type Inches (mm) A B C D E H Thickness Pattern
Through-Type
TP2201 W125 1/8 1.38 0.69 0.31 3.62 1.00 7.18 0.50
(3.18) (35.05) (17.53) (7.87) (91.95) (25.40) (182.37) (12.70)
TP4401 SW250 1/4 1.75 0.88 0.44 3.62 1.19 7.25 0.62
(6.35) (44.45) (22.35) (11.18) (91.95) (30.23) (184.15) (15.75) See
TP6601 SW375 3/8 2.00 1.00 0.53 3.62 1.38 7.31 0.75 Figure 1
(9.52) (50.80) (25.40) (13.46) (91.95) (35.05) (185.67) (19.05)
TP8801 SW500 1/2 2.50 1.25 0.53 3.62 1.75 7.44 1.00
(12.70) (63.50) (31.75) (13.46) (91.95) (44.45) (188.98) (25.40)
Angle-Type
TP2202 W125 1/8 1.00 0.75 0.31 3.62 1.38 7.62 0.50
(3.18) (25.40) (19.05) (7.87) (91.95) (35.05) (193.55) (12.70)
TP4402 SW250 1/4 1.19 0.88 0.44 3.62 1.75 7.81 0.62
(6.35) (30.23) (22.35) (11.18) (91.95) (44.45) (198.37) (15.75) See
TP6602 SW375 3/8 1.38 1.00 0.53 3.62 2.00 7.94 0.75 Figure 2
(9.52) (35.05) (25.40) (13.46) (91.95) (50.80) (201.68) (19.05)
TP8802 SW500 1/2 1.75 1.25 0.53 3.62 2.50 8.19 1.00
(12.70) (44.45) (31.75) (13.46) (91.95) (63.50) (208.03) (25.40)
Note: All thermocouples are furnished complete with connection components unless otherwise All dimensions for reference only and subject to change.
specified. For prompt service, Parker Autoclave Engineers stocks select products. Consult your
local representative.
Maximum pressure rating is based on the lowest rating of any component.
Actual working pressure may be determined by tubing pressure rating, if lower.
Figure 1 Figure 2
C
C
H D H
D
E E
B B
A A
Through-Type Angle-Type
All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold. 3
Accessories - Sheath-type Thermocouples
Pressures to 60,000 psi (4137 bar)
Temperature Rating
Rating to 2,000F (1093C) at tip of thermocouple. (Refer to
adjacent Pressure/Temperature chart for elevated tempera-
tures.) Minimum operating temperature 0F (-17.8C)
Sheath Length
Differs for each size connection for optimum tip contact with
fluid stream.
Standard collar and gland are cold worked 316 SS for use up
Materials to 1200F (649C). When cold worked 316 SS collar and gland
Bodies are 15-5PH stainless steel. 316 sheath brazed into body are used, the physical properties are permanently altered after
with gold-nickel alloy brazing material. An aluminum terminal use above 800F (427C).
housing is threaded into the body for ready access to termi-
nals. An o-ring seal provides moisture protection. CAUTION: While testing has shown O-rings to provide satis-
factory service life, both cyclic and shelf life may vary widely
Ordering Information with differing service conditions, properties of reactants,
To order thermocouples for use in standard Parker Autoclave pressure and temperature cycling, and age of the O-ring.
Engineers tees or crosses, use order numbers listed in table FREQUENT INSPECTION SHOULD BE MADE to detect any
(fittings not included as standard). For custom length sheaths, deterioration, and O-rings replaced as required.
to extend through a vessel wall or cover, calculate sheath
length as follows: CAUTION: See appropriate pressure section in reference to
proper selection of tubing.
1. Add vessel wall or cover thickness to the distance the
sheath will extend into vessel.
2. When using a basic 1/4 Autoclave connection, subtract
dimension M for proper sheath length to order.
3. For all other connection sizes, add dimension N to
measurement obtained in step 1.
4. Order a custom length sheath by adding desired length in
inches as suffix to order number.
4 All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold.
Accessories - Sheath-type Thermocouples
Fits Tubing Dimensions - inches (mm)
Catalog Connection Size Element Fitting
Number Type Inches (mm) Type L M N H Pattern
Note: All thermocouples are furnished complete with connection components unless All dimensions for reference only and subject to change.
otherwise specified. For prompt service, Parker Autoclave Engineers stocks select
Basic assembly includes 1/4 connection with adapters for other O.D. tube sizes. products. Consult your local representative.
TSJ24 and TSK24 do not extend past the wall of the bore.
Maximum pressure rating is based on the lowest rating of any component.
Actual working pressure may be determined by tubing pressure rating, if lower.
Figure 1 Figure 2
1.25"
(31.75)
TOP FACE
OF COVER
SHEATH TEE OR
6.375" DIAMETER
CROSS
(161.93) 0.062"
(1.57mm)
N
H
L SHEATH
TOP FACE DIAMETER
OF COVER
3.75" 0.062"
TEE OR
(95.25) (1.57mm)
CROSS
Note: The tee shown in both figures are for reference only. Tee is not included.
All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold. 5
Accessories - Thermowells
Pressures to 20,000 psi (1379 bar)
Thermowells are used to provide isolation between a Care must be taken in determining the material used for
temperature sensor and the environment, such as liquid or the thermowell as well as other factors. Parker Autoclave
gas. Thermowells protect the sensor from pressure, corrosion, Engineers offers design assistance that includes pressure,
abrasion or vibration caused by the process medium. temperature and vibration effect of the fluids. This vibration
Thermowells allow the temperature sensor to be removed can cause well stem failure.
and replaced without compromising either the ambient region Standard and special thermowell materials available:
or the process. 316 Stainless Steel
Hastelloy
Parker Autoclave Engineers manufactures thermowells from Inconel
solid bar stock to accommodate applications in the petro- Connection gland included
chemical, chemical, refining, power and other process indus- To order Parker Autoclave Engineers thermowell assemblies,
tries for many years. please refer to our order guide to assist in determining your
needs. Contact your local representative or the factory for
Parker Autoclave Engineers manufactures 316SS thermowells technical assistance and application suggestions.
capable of connecting to a 1" (SF1000CX) Parker Autoclave
Engineers female medium pressure connection.
-10 90
TEMPERATURE SENSOR
THERMOWELL
HEADER COUPLING
PIPE
6 All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold.
Ordering Information
+015 +.381
A -.000 -.000mm
2.350
(59.69)
DIA
DIA
1/2 NPT
1.44
See Note
Cover Thickness
Note: Thermowells fit Autoclave's 1" medium pressure connection. (SF1000-CX). 1" connection insertion length is 1.44" (36.76).
All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold. 7
Accessories - Universal Safety Heads
Pressures to 110,000 psi (7584 bar)
The 1/2F style features a 1/2 blow-out diameter and a flat seat Consult Local Sales Representative for safety head assemblies rated above
which can be ordered in pressures from 500 to 10,000 psi 60,000 psi (4137 bar).
(35 to 690 bar).
8 All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold.
Ordering Information Hold-down nut torque requirements vs. rupture disc
To order an Parker Autoclave Engineers Universal Safety Head, burst pressure rating @ RT
use the catalog order number from table. ADD THE SIZE OF
@ RT
1/4 angle disc
since the disc size determines which hold-down ring will be 30,000
furnished with the safety head.) Note: Plug is included. (2068)
3/16 flat disc
15,000
Hold-down nut torque values (1034)
1/2 flat disc
Torque@ Torque@
Minimum Maximum Rupture Hold-down 0 30 60 90 120 150
Pressure Pressure Disc Ring (40.6) (81.3) (122.4) (162.7) (203.3)
Ft. lb. psi Ft. lb. psi inches Part Number
(N.m) (bar) (N.m) (bar) Torque ft.lb (N.m)
20 5,000 90 26,500 3/16 Flat= 112A-0439
(27.1) (345) (122.0) (1827)
40 4,000 90 10,000 1/2 Flat 1050-7434
(54.2) (276) (122.0) (690)
20 4,000 140 60,000 1/4 Angle 108A-0439
(27.1) (276) (189.8) (4137)
3/16 flat seat disc cannot be used with safety head assemblies SS6600, SS8600, 40CS9600 and
CSX9600. Torque values for intermediate pressures may be linearily interpolated. Use minimum torque
value for pressures lower than those shown.
Outlet C Inlet
E
D Body
Inlet Inlet
Low-Pressure
SS2600 2010- 101A- 3/16 W125 15,000 15 0.094 0.125 0.188 0.25 0.50 1.00 2.13
7035 0434 & (1034.2) (20.3) (2.39) (3.15) (4.78) (6.35) (12.7) (25.4) (53.96)
1/2
SS4600 2020- 102A- Flat SW250 15,000 15 0.125 0.250 0.188 0.25 0.50 1.00 2.13
7035 0434 1040-7434 (1034.2) (20.3) (3.18) (6.35) (4.78) (6.35) (12.7) (25.4) (53.96)
SS6600 2030- 103A- SW375 15,000 15 0.250 0.375 NA 0.25 0.50 1.00 2.13
7035 0434 1/4 (1034.2) (20.3) (6.35) (9.53) (6.35) (12.7) (25.4) (53.96)
Angle
SS8600 2040- 104A- 1030-0241 SW500 10,000 20 0.375 0.375 NA 0.25 0.50 1.00 2.13
7035 0434 (690.0) (22.1) (9.53) (9.53) (6.35) (12.7) (25.4) (53.96)
Note: Interchangeable hold-down rings permit use of several different sizes and types of rupture All dimensions for reference only and subject to change.
disc in a single safety head. For prompt service, Parker Autoclave Engineers stocks select products.
Consult your local representative.
All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold. 9
1/2 Flat Disc illustrated in safety head
Rupture
Hold-down Hold-down Disc Connection
Nut Ring
3/8" NPT Plug
Outlet C Inlet
E
D Body
Inlet Inlet
Medium-Pressure
CSX4600 101A- 2010- 3/16 SF250CX 20,000 15 0.094 0.141 0.188 0.25 0.50 1.00 2.19
&
1731 7823 1/2
(1378.9) (20.3) (2.39) (3.58) (4.78) (6.35) (12.7) (25.4) (55.63)
CSX6600 102A- 2010- Flat SF375CX 20,000 20 0.171 0.250 0.188 0.25 0.50 1.00 2.19
1040-7434
1731 7844 (1378.9) (27.1) (4.34) (6.35) (4.78) (6.35) (12.7) (25.4) (55.63)
1/4
CSX9600 101A- 102A- Angle SF562CX 20,000 30 0.312 0.375 NA 0.25 0.50 1.00 2.19
0438 0438 1030-0241 (1378.9) (40.6) (7.92) (9.53) (6.35) (12.7) (25.4) (55.63)
High-Pressure
CS4600 2010- 1030- 3/16 F250C 60,000 20 0.082 0.125 0.188 0.25 0.50 1.00 2.25
7036 4877 & (4136.8) (2.8) (2.08) (3.18) (4.78) (6.35) (12.7) (25.4) (57.15)
1/2
CS6600 2020- 1030- Flat F375C 60,000 40 0.125 0.219 0.188 0.25 0.50 1.00 2.25
7036 6096 1040-7434 (4136.8) (5.5) (3.18) (5.56) (4.78) (6.35) (12.7) (25.4) (57.15)
CS9600 2030- 1030- F562C 60,000 80 0.188 0.281 0.188 0.25 0.50 1.19 2.25
7036 6097 (4136.8) (11.1) (4.78) (7.13) (4.78) (6.35) (12.7) (30.23) (57.15)
1/4
40CS9600 2030- 101C- Angle F562C40 40,000 80 0.250 0.281 NA 0.25 0.50 1.19 2.25
7036 7192 1030-0241 (2757.9) (11.1 (6.35) (7.13) (6.35) (12.7) (30.23) (57.15)
Port E* - Minimum disc blow-out diameter of hold down ring Maximum pressure rating is based on the lowest rating of any component.
Actual working pressure may be determined by tubing pressure rating, if lower.
Note: Interchangeable hold-down rings permit use of several different sizes and types of rupture
disc in a single safety head. All dimensions for reference only and subject to change.
For prompt service, Parker Autoclave Engineers stocks select products. Consult your local
representative.
10 All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold.
Accessories - Prebulged Rupture Discs
Ordering Information
Specify quantity, disc size, type, material and temperature.
Indicate desired rupture rating which should be at least
110% of operating pressure. The burst rating tolerance
is +/- 5% of the furnished tag rating. Discs are rated at
72F (22C). 3/16 F Ref. O.D.
.375" (9.53 mm) 1/4A Ref. O.D.
0% optional manufacturing range is available upon request. 1/2 F Ref. O.D.
.62" (15.7 mm)
0% option provides the burst pressure requested with a .68" (17.3 mm)
PTFE coating available on one or both sides to increase minimum rupture rating. All dimensions for reference only and subject to change.
For prompt service, Parker Autoclave Engineers stocks select products.
CAUTION: High pressure-to-rupture ratios, severe pressure or temperature cycling, corrosion and Consult your local representative.
metal fatigue affect disc life and rupture pressure. Frequent disc replacement may be desirable to avoid
premature rupture. Rupture disc manufacturers recommended a 140 to 170 percent margin on disc
ratings for extended disc life.
All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold. 11
Rupture Disc Stock Part List - 3/16 Flat Disc
Part Pressure Pressure
Number Description Material Range Range
(psi) (bar)
12 All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold.
Rupture Disc Stock Part List - 1/4 Angle Disc
All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold. 13
Rupture Disc Stock Part List - 1/4 Angle Disc - cont
14 All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold.
Rupture Disc Stock Part List - 1/2 Flat Disc
All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold. 15
Accessories - Instrument Quality Pressure Gauges
Pressures to 80,000 psi (5116 bar)
16 All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold.
Note: Gauge connections are 1/4 (F250C) coned-and-threaded connection. Furnished with collar and gland.
inches - (mm)
P-0713 4-1/2 (114.3)
P-0714 6 (152.4)
Gauge A B C
**Bourdon tube material for 0-30,000 psi (0-2068 bar) Size cutout inches - (mm) inches - (mm)
inches - (mm) inches - (mm)
gauge is K Monel. Bourdon tube material for 0-50,000 psi
4-1/2 (114.3) 4.937 (125.39) 5.375 (136.52) .218 (5.54)
(0-3447 bar) and 0-80,000 psi (0-5116 bar) gauge is
6 (152.4) 6.437 (163.49) 7.0 (177.80) .218 (5.54)
Inconel 718.
All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold. 17
Accessories - Gauge/Instrument Snubbers
Pressures to 60,000 psi (4137 bar)
When sudden flow is seen, the poppet will rise, blocking the
pressure surge and a small bleed hole in the poppet will allow
pressure to slowly equalize. When the pressure is equalized,
the poppet will then drop back down allowing normal flow to
the gauge. A filter is used to prevent the hole in the plug from
becoming plugged. The snubber must be mounted in the
vertical position as indicated on the unit.
SNB F H4 F H4
Gauge Female Inlet Female Outlet
Snubber Connection Connection
INLET
18 All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold.
Accessories - Gauge/Instrument Snubbers
SNBFH4FH4 60,000 (4137) 3.36 (85.34) 2.50 (63.50) 0.50 (12.70) 0.63 (15.33) 1.19 (30.15) 1
SNBFH4MH4 60,000 (4137) 4.05 (102.87) 2.50 (63.50) 0.50 (12.70) 0.63 (15.33) 1.19 (30.15) 2
SNBMH6MH4 60,000 (4137) 3.68 (93.47) 2.13 (54.10) 1.50 (38.10) 0.75 (19.05) 1.19 (30.15) 3
Figure 1
A B
B
D HEX HEX
D HEX A HEX
C
B C
C
C
D HEX HEX
C A
A C
B
Figure 2 B
HEX
HEX B D HEX D HEX
HEX C C
D HEX
Figure 3
A C
A B C
B
A C
HEX D HEX
B
HEX D HEX
HEX D HEX
All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold. 19
WARNING
FAILURE, IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS AND/OR SYSTEMS DESCRIBED HEREIN OR RELATED ITEMS CAN CAUSE DEATH, PERSONAL INJURY AND PROPERTY DAMAGE.
This document and other information from Parker Hannifin Corporation, its subsidiaries and authorized distributors provide product and/or system options for further investigation by users having technical
expertise. It is important that you analyze all aspects of your application and review the information concerning the product or system in the current product catalog. Due to the variety of operating conditions
and applications for these products or systems, the user, through its own analysis and testing, is solely responsible for making the final selection of the products and systems and assuring that all performance,
safety and warning requirements of the application are met. The products described herein, including without limitation, product features, specifications, designs, availability and pricing, are subject to change by
Parker Hannifin Corporation and its subsidiaries at any time without notice.
Offer of Sale
The items described in this document are available for sale by Parker Hannifin Corporation, its subsidiaries or its authorized distributors. Any sale contract entered by Parker will be governed by the provisions
stated in Parker's standard terms and conditions of sale (copy available upon request).
2013 Parker Hannifin Corporation | Autoclave Engineers is a registered trademark of the Parker Hannifin Corporation 02-0134SE January2013
Instrumentation Products Division Parker Hannifin Manufacturing Ltd. Caution! Parker Autoclave Engineers Valves, Fittings and Tools are
Autoclave Engineers Operation Instrumentation Products Division, Europe not designed to work with common commercial instrument tubing
and will only work with tubing built to Parker Autoclave Engineers
8325 Hessinger Drive Industrial Estate Whitemill
AES Specifications. Failure to do so will void warranty.
Erie, Pennsylvania 16509-4679 USA Wexford, Republic of Ireland
PH: 814-860-5700 FAX: 814-860-5811 PH: 353 53 914 1566
www.autoclave.com FAX: 353 53 914 1582 ISO-9001 Certified
Sour Service Products
Pressures to 30,000 psi (2068 bar)
www.autoclaveengineers.com
All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold.
www.autoclave.com 1
Sour Service Products - Oil and Gas Service Valves and Fittings
Oil and Gas Service Valves and Fittings
Note:
For connection torque values, see tools section,
special material connection torque table.
API Type I API Type II API Type III All sour oil and gas valves and fittings supplied
connector connector connector without collars and glands unless otherwise
specified.
2 All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold.
Sour Service Products - Wellhead Gauge and Bleed Valves
Pressures to 20,000 psi (1379 bar)
Bleed Valve
20BV 3/8 SM375CX 0.093 (2.36) - 10,000 (690)
20BV 9/16 SM562CX 0.093 (2.36) - 10,000 (690)
30BV 9/16 M562C 0.093 (2.36) - 20,000 (1379)*
Notes:
* Rating shown is in closed position.
Rating @ 15,000 psi (1034 bar) in open position. Gauge Valve Features:
One inlet, three outlet ports, all ports are 9/16" API test
Parker Autoclave Engineers' Wellhead Gauge valves are
and gauge connection ports.
designed for reliable shut-off service at a maximum work-
Metal-to-metal bubble tight shut-off
ing pressure of 20,000 psi (1379 bar). The Wellhead Gauge
Packing below stem threads
and Bleed Valves are standard in 316 stainless steel annealed
Two piece non-rotating stem on standard service and
material and comply with NACE MR0175. Special materials
SOG valves
available on request.
Optional use of long nipples in the inlet for installation on
Applications: headers that are insulated.
Wellhead Gauge Valve
Bleed Valve Features:
Sample Lines
One piece hex construction allows easy installation
Instrument calibration
Vent port tapped for plumbing to safe area
Tee handle for easy operation
Bleed Valve
Positive blow out prevention on stem
Pressure bleed
Compatible with standard API test and gauge connections
for 15,000 psi (1034 bar) service.
Ordering Procedure
Wellhead Gauge Valve - 30GV-SOGWO valves are furnished without collars and glands unless otherwise specified.
30GV 9 07 8 SOGWO
Valve Outside Diameter Stem Body
Series Tube Size Type Pattern
20GV 6-3/8 00 - one piece VEE stem 8 - 4 ports, 1 inlet, 3 outlets Sour gas
30GV 9-9/16 07- non-rotating VEE stem without
glands and
collars
Bleed Valve
Typical catalog number: 30BV9002- SOG
30BV 9 00 2 SOG
Valve Outside Diameter Stem Body
Series Tube Size Type Pattern
20BV 6-3/8 00 - one piece VEE stem 2 -Angle Sour gas
30BV 9-9/16
All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold. 3
Wellhead Gauge Valve
SF375CX 3/8 10,000 2.00 3.12 2.00 4.75 1.13 1.00 0.50 0.94 3.00
20GV6078-SOG
(690) (50.80) (79.25) (50.80) (120.65) (28.58) (25.40) (12.70) (23.83) (76.20)
SF562CX 9/16 10,000 2.00 3.88 2.75 4.54 1.31 1.38 0.66 0.94 3.00 See
20GV9078-SOG
(690) (50.80) (98.55) (69.85) (115.31) (33.27) (34.93) (16.76) (23.83) (76.20) Figure 1
F562C 9/16 20,000 2.00 3.88 2.75 4.75 1.31 1.38 0.66 0.94 3.00
30GV9078-SOG
(1379) (50.80) (98.55) (69.85) (120.65) (33.27) (34.93) (16.76) (23.83) (76.20)
Mounting Dimensions
J
K L M Dia.
20GV6078-SOG .25 (6.4) .25 (6.4) .28 (7.1)
20GV9078-SOG .38 (9.7) .38 (9.7) .28 (7.1)
30GV9078-SOG .38 (9.7) .38 (9.7) .28 (7.1)
D K
"M" L
OUT
A
H
G OUT
IN GAUGE
F
E
C B
OUT
Bleed Valve
D HEX C
A
B
Connection
Type
4 All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold.
Sour Service Products - 30VM-SOGWO Series
Pressures to 20,000 psi (1379 bar)
Pressure/
Tube Temperature
Outside Rating
Diameter Orifice psi (bar)
Size Connection Size Rated @ Room
Inches Type Inches (mm) Cv* Temperature**
Notes:
* CV values shown are for 2-way straight valve pattern. For 2-way
angle patterns, increase CV value 50%.
304SS
6
POWDER COATED
PACKING STAINLESS STEEL
Number of turns open
GLAND HANDLE
1
Vee Stem
0
10 20 30 40 50 60 70 80 90 100
CHOICE OF VEE OR
REGULATING STEM TIP % of rated Cv
METAL-TO-METAL SEATING
Note: For information on standard 30VM valves, refer to the Needle Valve Section.
Ordering Procedure
The 30VM-SOGWO Series valves are furnished without collars and glands, unless otherwise specified.
30VM 4 00 1 SOGWO
Valve Outside Diameter Stem/Seat Body
Series Tube Size Type Pattern
4-1/4 00 - One piece rotating Vee stem 1 - two-way straight SOG-Sour Gas
6-3/8 01 - One piece rotating Regulating stem 2 - two-way angle SOGWO-Sour Gas
9-9/16 without glands &
07 - non-rotating Vee stem (on-off service) 3 - three-way, two on pressure
collars
08 - non-rotating Regulating stem 4 - three-way, one on pressure
(tapered tip for regulating and shutoff) 5 - three-way, two-stem
80 - One piece Vee stem with replaceable seat manifold valve
81 - One piece Regulating stem with
replaceable seat
88 - Regulating stem with replaceable seat
All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold. 5
Valve Maintenance
2-Way Straight
30VM4001-SOGWO VEE 1/4 0.094 2.00 1.00 0.50 1.50 1.12 2.00 3.00 1.00 0.22 4.62 0.69 0.38 1.00
30VM4081-SOGWO REG (6.35) (2.39) (50.80) (25.40) (12.70) (38.10) (28.45) (50.80) (76.20) (25.40) (5.59) (117.35) (17.53) (9.65) (25.40)
30VM6001-SOGWO VEE 3/8 0.125 2.00 1.00 0.53 1.50 1.12 2.00 3.00 1.00 0.22 4.68 0.69 0.38 1.00 See
30VM6081-SOGWO REG (9.53) (3.18) (50.80) (25.40) (13.46) (38.10) (28.45) (50.80) (76.20) (25.40) (5.59) (118.87) (17.53) (9.65) (25.40) Figure 1
30VM9001-SOGWO VEE 9/16 0.125 2.62 1.31 0.81 1.56 1.12 2.44 3.00 1.00 0.28 5.06 0.69 0.38 1.50
30VM9081-SOGWO REG (14.29) (3.18) (66.55) (33.27) (20.57) (39.62) (28.45) (61.98) (76.20) (25.40) (7.11) (128.52) (17.53) (9.65) (38.10)
2-Way Angle
30VM4002-SOGWO VEE 1/4 0.094 2.00 1.00 0.50 1.12 2.00 3.00 1.00 0.22 4.62 0.69 0.38 1.00
30VM4082-SOGWO REG (6.35) (2.39) (50.80) (25.40) (12.70) (28.45) (50.80) (76.20) (25.40) (5.59) (117.35) (17.53) (9.65) (25.40)
30VM6002-SOGWO VEE 3/8 0.125 2.00 1.00 0.53 1.12 2.12 3.00 1.00 0.22 4.74 0.69 0.38 1.00 See
30VM6082-SOGWO REG (9.53) (3.18) (50.80) (25.40) (13.46) (28.45) (53.85) (76.20) (25.40) (5.59) (120.40) (17.53) (9.65) (25.40) Figure 2
30VM9002-SOGWO VEE 9/16 0.125 2.62 1.31 0.81 1.12 2.44 3.00 1.00 0.28 5.06 0.69 0.38 1.50
30VM9082-SOGWO REG (14.29) (3.18) (66.55) (33.27) (20.57) (28.45) (61.98) (76.20) (25.40) (7.11) (128.52) (17.53) (9.65) (38.10)
3-Way / 2 on Pressure
30VM4003-SOGWO VEE 1/4 0.094 2.00 1.00 0.50 1.50 1.12 2.12 3.00 1.00 0.22 4.74 0.69 0.38 1.00
30VM4083-SOGWO REG (6.35) (2.39) (50.80) (25.40) (12.70) (38.10) (28.45) (53.85) (76.20) (25.40) (5.59) (120.40) (17.53) (9.65) (25.40)
30VM6003-SOGWO VEE 3/8 0.125 2.00 1.00 0.53 1.50 1.12 2.50 3.00 1.00 0.22 5.12 0.69 0.38 1.00 See
30VM6083-SOGWO REG (9.53) (3.18) (50.80) (25.40) (13.46) (38.10) (28.45) (63.50) (76.20) (25.40) (5.59) (130.05) (17.53) (9.65) (25.40) Figure 3
30VM9003-SOGWO VEE 9/16 0.125 2.62 1.31 0.81 1.56 1.12 2.88 3.00 1.00 0.28 5.49 0.69 0.38 1.50
30VM9083-SOGWO REG (14.29) (3.18) (66.55) (33.27) (20.57) (39.62) (28.45) (73.15) (76.20) (25.40) (7.11) (139.45) (17.53) (9.65) (38.10)
G - Packing gland mounting hole drill size All dimensions for reference only and subject to change. For prompt service,
G1 - Bracket mounting hole size * H Dimension is with stem in the closed position. Parker Autoclave Engineers stocks
Panel mounting drill size: 0.22 all valves. select products. Consult factory.
G1 M M G1 M G1 M M
M
G H N G H N G
H N
D1
D1 D D
D
E E
E
C
C
C
B
A B
B A
A
2-Way Straight 2-Way Angle 3-Way / 2 on Pressure
6 All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold.
Dimensions - inches (mm) Block
Catalog Outside
Stem Orifice Thick- Valve
Diameter
Number Type
Tube
Diameter
A B C D D1 E F G G1 H* M N ness Pattern
3-Way / 1 on Pressure
30VM4004-SOGWO VEE 1/4 0.094 2.00 1.00 0.50 1.12 2.00 3.00 1.00 0.22 4.62 0.69 0.38 1.00
30VM4084-SOGWO REG (6.35) (2.39) (50.80) (25.40) (12.70) (28.45) (50.80) (76.20) (25.40) (5.59) (117.35) (17.53) (9.65) (25.40)
30VM6004-SOGWO VEE 3/8 0.125 2.00 1.00 0.53 1.12 2.12 3.00 1.00 0.22 4.74 0.69 0.38 1.00 See
30VM6084-SOGWO REG (9.53) (3.18) (50.80) (25.40) (13.46) (28.45) (53.85) (76.20) (25.40) (5.59) (120.40) (17.53) (9.65) (25.40) Figure 4
30VM9004-SOGWO VEE 9/16 0.125 2.62 1.31 0.81 1.12 2.44 3.00 1.00 0.28 5.12 0.69 0.38 1.50
30VM9084-SOGWO REG (14.29) (3.18) (66.55) (33.27) (20.57) (28.45) (61.98) (76.20) (25.40) (7.11) (130.05) (17.53) (9.65) (38.10)
G - Packing gland mounting hole drill size All dimensions for reference only and subject to change. For prompt service,
G1 - Bracket mounting hole size * H Dimension is with stem in the closed position. Parker Autoclave Engineers stocks
Panel mounting drill size: 0.22 all valves. select products. Consult factory.
All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold. 7
Sour Service Products - 60VM-SOGWO Series
Pressures to 30,000 psi (2068 bar)
Pressure/
Tube Temperature
Outside Rating
Diameter Orifice psi (bar)
Size Connection Size Rated @ Room
Inches Type Inches (mm) Cv* Temperature**
Notes:
* CV values shown are for 2-way straight valve pattern. For 2-way
angle patterns, increase CV value 50%.
1
Vee Stem
HIGH PRESSURE 0
CONED-AND-THREADED
CONNECTIONS
10 20 30 40 50 60 70 80 90 100
CHOICE OF VEE OR
REGULATING STEM TIP
METAL-TO-METAL SEATING
% of rated Cv
Note: For information in standard 60VM valves refer to the Needle Valve Section.
Ordering Procedure
The 60VM-SOGWO Series valves are furnished without glands and collars, unless otherwise specified.
60VM 4 07 1 SOGWO
Valve Outside Diameter Stem/Seat Body
Series Tube Size Type Pattern
4-1/4 07 - non-rotating Vee stem 1 - two-way straight SOG-Sour Gas
6-3/8 (on-off service) 2 - two-way angle SOGWO-Sour
9-9/16 08 - non-rotating regulating stem Gas without
3 - three-way, two on pressure
(tapered tip for regulating and glands & collars
4 - three-way, one on pressure
shutoff)
5 - three-way, two-stem
81 - Regulating one piece stem with
manifold valve
replaceable seat
87 - Vee stem with replaceable seat
88 - Regulating stem with replaceable
seat
8 All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold.
Valve Maintenance
Repair Kits: add R to the front of valve catalog Note: All sour service valves and fittings supplied without col-
number for proper repair kit. lars and glands unless otherwise specified.
(Example: R60VM4071-SOGWO)
Valve Bodies: Valve bodies are available. Order using the
eight (8) digit part number found in the valve drawing or
contact your Sales Representative for information.
Consult your Parker Autoclave Engineers representative for
pricing on repair kits and valve bodies. Refer to the Tools,
Installation, Operation and Maintenance section for proper
maintenance procedures.
2-Way Straight
60VM4071-SOGWO VEE 1/4 0.062 2.00 1.00 0.50 1.69 1.31 2.12 3.00 1.00 0.22 4.75 0.69 0.38 1.00
60VM4081-SOGWO REG (6.35) (1.57) (50.80) (25.40) (12.70) (42.93) (33.27) (53.85) (76.20) (25.40) (5.59) (120.65) (17.53) (9.65) (25.40)
60VM6071-SOGWO VEE 3/8 0.062 2.00 1.00 0.53 1.69 1.31 2.25 3.00 1.00 0.22 4.87 0.69 0.38 1.00 See
Figure 1
60VM6081-SOGWO REG (9.53) (1.57) (50.80) (25.40) (13.46) (42.93) (33.27) (57.15) (76.20) (25.40) (5.59) (123.70) (17.53) (9.65) (25.40)
60VM9071-SOGWO VEE 9/16 0.078 2.62 1.31 0.72 1.75 1.31 2.50 3.00 1.00 0.28 5.13 0.69 0.38 1.50
60VM9081-SOGWO REG (14.29) (1.98) (66.55) (33.27) (18.29) (45.45) (33.27) (63.50) (76.20) (25.40) (7.11) (130.30) (17.53) (9.65) (38.10)
2-Way Angle
60VM4072-SOGWO VEE 1/4 0.062 2.00 1.00 0.50 1.31 2.38 3.00 1.00 0.22 5.00 0.69 0.38 1.00
60VM4082-SOGWO REG (6.35) (1.57) (50.80) (25.40) (12.70) (33.27) (60.45) (76.20) (25.40) (5.59) (127.00) (17.53) (9.65) (25.40)
60VM6072-SOGWO VEE 3/8 0.062 2.00 1.00 0.53 1.31 2.62 3.00 1.00 0.22 5.25 0.69 0.38 1.00 See
Figure 2
60VM6082-SOGWO REG (9.53) (1.57) (50.80) (25.40) (13.46) (33.27) (66.55) (76.20) (25.40) (5.59) (133.35) (17.53) (9.65) (25.40)
60VM9072-SOGWO VEE 9/16 0.078 2.62 1.31 0.72 1.31 2.81 3.00 1.00 0.28 5.44 0.69 0.38 1.50
60VM9082-SOGWO REG (14.29) (1.98) (66.55) (33.27) (18.29) (33.27) (71.37) (76.20) (25.40) (7.11) (138.18) (17.53) (9.65) (38.10)
3-Way / 2 on Pressure
60VM4073-SOGWO VEE 1/4 0.062 2.00 1.00 0.50 1.69 1.31 2.12 3.00 1.00 0.22 4.75 0.69 0.38 1.00
60VM4083-SOGWO REG (6.35) (1.57) (50.80) (25.40) (12.70) (42.93) (33.27) (53.85) (76.20) (25.40) (5.59) (120.65) (17.53) (9.65) (25.40)
60VM6073-SOGWO VEE 3/8 0.062 2.00 1.00 0.53 1.69 1.31 2.25 3.00 1.00 0.22 4.87 0.69 0.38 1.00 See
60VM6083-SOGWO REG (9.53) (1.57) (50.80) (25.40) (13.46) (42.93) (33.27) (57.15) (76.20) (25.40) (5.59) (123.70) (17.53) (9.65) (25.40) Figure 3
60VM9073-SOGWO VEE 9/16 0.078 2.62 1.31 0.72 1.75 1.31 2.50 3.00 1.00 0.28 5.13 0.69 0.38 1.50
60VM9083-SOGWO REG (14.29) (1.98) (66.55) (33.27) (18.29) (45.45) (33.27) (63.50) (76.20) (25.40) (7.11) (130.30) (17.53) (9.65) (38.10)
G - Packing gland mounting hole drill size All dimensions for reference only and subject to change. For prompt service,
G1 - Bracket mounting hole size * H Dimension is with stem in the closed position. Parker Autoclave Engineers stocks
Panel mounting drill size: 0.22 all valves. select products. Consult factory.
G1 M G1 M M
G1 M M M
G H N G
G H N
H N
D1
D1 D D
D E
E
E C
C C
B B
A B A
A
2-Way Straight 2-Way Angle 3-Way / 2 on Pressure
All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold. 9
Dimensions - inches (mm) Block
Catalog Outside
Stem Orifice Thick- Valve
Diameter
Number Type
Tube
Diameter
A B C D D1 E F G G1 H* M N ness Pattern
3-Way / 1 on Pressure
60VM4074-SOGWO VEE 1/4 0.062 2.00 1.00 0.50 1.31 2.38 3.00 1.00 0.22 5.00 0.69 0.38 1.00
60VM4084-SOGWO REG (6.35) (1.57) (50.80) (25.40) (12.70) (33.27) (60.45) (76.20) (25.40) (5.59) (127.00) (17.53) (9.65) (25.40)
60VM6074-SOGWO VEE 3/8 0.062 2.00 1.00 0.53 1.31 2.62 3.00 1.00 0.22 5.25 0.69 0.38 1.00 See
60VM6084-SOGWO REG (9.53) (1.57) (50.80) (25.40) (13.46) (33.27) (66.55) (76.20) (25.40) (5.59) (133.35) (17.53) (9.65) (25.40) Figure 4
60VM9074-SOGWO VEE 9/16 0.078 2.62 1.31 0.72 1.31 2.81 3.00 1.00 0.28 5.44 0.69 0.38 1.50
60VM9084-SOGWO REG (14.29) (1.98) (66.55) (33.27) (18.29) (33.27) (71.37) (76.20) (25.40) (7.11) (138.18) (17.53) (9.65) (38.10)
G - Packing gland mounting hole drill size All dimensions for reference only and subject to change. For prompt service,
G1 - Bracket mounting hole size * H Dimension is with stem in the closed position. Parker Autoclave Engineers stocks
Panel mounting drill size: 0.22 all valves. select products. Consult factory.
D D D E
E D1
E C
C B
C
D1 A
B B
A A
10 All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold.
Sour Service Products - High Pressure Fittings
Pressures to 30,000 psi (2068 bar)
Connection Components
Type SOGWO valves and fittings are furnished without glands and collars. To order these components separately, use order num-
bers listed. When using plug, collar is not required.
Add tube size ( ) Example: To ensure proper fit use Parker Autoclave Engineers tubing.
1/4 - 40 1/4 Gland - CGL (40) - 316 SOG
3/8 - 60
9/16 - 90
F250C CGL40-316SOG CCL40-316SOG CP40-316SOG Parker Autoclave Engineers high pressure SOG fittings 1/4, 3/8
F375C CGL60-316SOG CCL60-316SOG CP60-316SOG and 9/16 connection components to 30,000 psi (2068 bar).
F562C CGL90-316SOG CCL90-316SOG CP90-316SOG For use with 30VM-SOGWO, 60VM-SOGWO valves and fittings.
Associated Products
A complete line of high pressure anti-vibration collet gland assemblies is available. Please refer to high pressure fitting and tubing
section.
All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold. 11
Outside Pressure Dimensions - inches (mm)
Catalog Connection Minimum Block Fitting
Diameter Rating Opening A B C D E F G Thickness
Number Type Pattern
Tube psi (bar)* Typical Thickness
Elbow
CL4400- F250C 1/4 30,000 0.094 1.00 1.50 0.50 0.63 0.62 0.88 0.75
SOGWO (6.35) (2068.39) (2.39) (25.40) (38.10) (12.70) (15.88) (15.75) (22.35) (19.05)
CL6600- F375C 3/8 30,000 0.125 1.50 2.00 0.53 0.81 1.00 1.25 1.00 See
SOGWO (9.53) (2068.39) (3.18) (38.10) (50.80) (13.46) (20.62) (25.40) (31.75) (25.40) Figure 1
CL9900- F562C 9/16 30,000 0.188 1.88 2.62 0.81 1.19 1.12 1.88 1.50
SOGWO (14.29) (2068.39) (4.78) (47.75) (66.55) (20.57) (30.23) (28.45) (47.75) (38.10)
Tee
CT4440- F250C 1/4 30,000 0.094 1.25 2.00 0.50 0.63 0.88 1.00 1.00
SOGWO (6.35) (2068.39) (2.39) (31.75) (50.80) (12.70) (15.88) (22.35) (25.40) (25.40)
CT6660- F375C 3/8 30,000 0.125 1.56 2.00 0.53 0.81 1.06 1.00 1.00 See
SOGWO (9.53) (2068.39) (3.18) (39.62) (50.80) (13.46) (20.62) (26.92) (25.40) (25.40) Figure 2
CT9990- F562C 9/16 30,000 0.188 2.12 2.62 0.81 1.19 1.38 1.31 1.50
SOGWO (14.29) (2068.39) (4.78) (53.85) (66.55) (20.57) (30.23) (35.05) (33.27) (38.10)
Cross
CX4444- F250C 1/4 30,000 0.094 1.25 2.00 0.50 0.63 0.62 1.00 1.00
SOGWO (6.35) (2068.39) (2.39) (31.75) (50.80) (12.70) (15.88) (15.75) (25.40) (25.40)
CX6666- F375C 3/8 30,000 0.125 2.12 2.00 0.53 0.81 1.06 1.00 1.00 See
SOGWO (9.53) (2068.39) (3.18) (53.85) (50.80) (13.46) (20.62) (26.92) (25.40) (25.40) Figure 3
CX9999- F562C 9/16 30,000 0.188 2.75 2.62 0.81 1.19 1.38 1.31 1.50
SOGWO (14.29) (2068.39) (4.78) (69.85) (66.55) (20.57) (30.23) (35.05) (33.27) (38.10)
*Maximum pressure rating is based on the lowest rating of any component. NOTE: All sour oil and gas valves and fittings supplied without collars and glands unless otherwise
Actual working pressure may be determined by tubing pressure rating, if lower. specified.
All dimensions for reference only and subject to change.
For prompt service, Parker Autoclave Engineers stocks select products. Consult your local representative.
F
D HEX C
F F
C C
E
D
D HEX
E HEX
E
A A A
B B
B
Note: Fittings such as 45 elbows, reducer elbows, and reducer 45 elbows are available upon request.
For mounting hole option add suffix PM to catalog number, consult factory for mounting hole dimensions.
Contact your local sales representative for additional information.
12 All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold.
Outside Pressure Dimensions - inches (mm)
Catalog Connection Minimum Block Fitting
Number Diameter Rating A B C D E F G Thickness
Type Opening Pattern
Tube psi (bar)* Typical Thickness
Bulkhead Coupling
60BF4433-SOGWO F250C 1/4 30,000 0.094 0.094 1.88 0.50 0.63 0.50 1.00 0.38
(6.35) (2068.39) (2.39) (23.88) (47.75) (12.70) (15.88) (12.70) (25.40) (9.65)
60BF6633-SOGWO F375C 3/8 30,000 0.125 1.12 2.38 0.53 0.81 0.78 1.38 0.38 See
(9.53) (2068.39) (3.18) (28.45) (60.45) (13.46) (20.62) (19.81) (35.05) (9.65) Figure 5
60BF9933-SOGWO F562C 9/16 30,000 0.188 1.69 2.75 0.81 1.19 1.00 1.88 0.38
(14.29) (2068.39) (4.78) (42.93) (69.85) (20.57) (30.23) (25.40) (47.75) (9.65)
*Maximum pressure rating is based on the lowest rating of any component. NOTE: All sour oil and gas valves and fittings supplied without collars and glands unless otherwise
Actual working pressure may be determined by tubing pressure rating, if lower. specified.
Figure 4 Figure 5
A HEX
G MAX
D F A D HEX
HEX
B C E
B C
Union Couplings are designed with a removable seat insert allowing disassembly and tubing removal without the necessity of loosening other items in a line.
All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold. 13
Sour Service Products - High Pressure Tubing
Pressures to 30,000 psi (2068 bar)
Tubing Tolerance
Nominal Tubing Size Tolerance/Outside Diameter
inches (mm) inches (mm)
Catalog Tube Fits Tube Size Inches (mm) Flow Working Pressure psi (bar)*
Number Material Connection Outside Inside Wall Area -325 to 100F 200F 400F 600F 800F
Type Diameter Diameter Thickness in.2 (mm2) -198 - 37.8C 93C 204C 316C 427C
MS15-254 316SS F250C 1/4 0.083 0.083 0.005 30,000 30,000 28,750 27,000 25,250
(6.35) (2.11) (2.11) (3.23) (2068.39) (2068.39) (1982.21) (1861.56) (1741.00)
MS15-252 316SS F375C 3/8 0.125 0.125 0.012 30,000 30,000 28,750 27,000 25,250
(9.53) (3.18) (3.18) (0.30) (2068.39) (2068.39) (1982.21) (1861.56) (1741.00)
MS15-251 316SS F562C 9/16 0.188 0.187 0.028 30,000 30,000 28,750 27,000 25,250
(14.29) (4.78) (4.75) (0.71) (2068.39) (2068.39) (1982.21) (1861.56) (1741.00)
NOTE: All sour oil and gas valves and fittings supplied without collars and glands unless otherwise specified.
14 All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold.
Sour Service Products - High Pressure Coned-and-Threaded Nipples
Pressures to 30,000 psi (2068 bar)
Special lengths
In addition to the standard lengths listed in the table below,
nipples are available in any custom length. Consult factory.
Materials
Catalog numbers in table refer to Type 316 Stainless steel.
Catalog numbers with suffix 316SOG denote 316SS annealed in
compliance with NACE MR0175.
CN4402- CN4403- CN4404- CN4406- CN4408- CN44010- CN44012- F250C 1/4 0.083 30,000
316SOG 316SOG 316SOG 316SOG 316SOG 316SOG 316SOG (6.35) (2.11) (2068.39)
CN6603- CN6604- CN6606- CN6608- CN66010- CN66012- F375C 3/8 0.125 30,000
316SOG 316SOG 316SOG 316SOG 316SOG 316SOG (9.53) (3.18) (2068.39)
Note:
1. See Sour Service tubing section for pressure ratings at various temperatures.
2. Parker Autocalve Engineers does not recommend bending of SOG tubing.
*Maximum pressure rating is based on the lowest rating of any component.
Actual working pressure may be determined by tubing pressure rating, if lower.
All dimensions for reference only and subject to change.
For prompt service, Parker Autoclave Engineers stocks select products. Consult your local representative.
All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold. 15
Sour Service Products - High Pressure Check Valves
Pressures to 30,000 (2068 bar)
NOTE: All sour oil and gas valves and fittings supplied without collars and glands unless
otherwise specified.
CAUTION: While testing has shown O-Rings to provide satisfactory service life, both cyclic and shelf
life may vary widely with differing service conditions, properties of reactants, pressure and temperature
cycling and age of the O-ring. FREQUENT INSPECTIONS SHOULD BE MADE to detect any deterioration,
and O-rings replaced as required.
16 All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold.
Sour Service Products - High Pressure Check Valves
*Maximum pressure rating is based on the lowest rating of any component. NOTE: All sour oil and gas valves and fittings supplied without collars and glands unless
Actual working pressure may be determined by tubing pressure rating, if lower. otherwise specified.
All dimensions for reference only and subject to change.
For prompt service, Parker Autoclave Engineers stocks select products. Consult your local representative.
Figure 1
A
B
HEX D HEX
C C
All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold. 17
Sour Service Products - Adapters/Couplings
Pressures to 30,000 psi (2068 bar)
A Connection
Male Female
Connection A 1/4 M250C 3/8 M375C 9/16 M562C 1/4 F250C 3/8 F375C 9/16 F562C
Connection B
1/4 M250C 60MAH4H4-SOG 60MAH4H6-SOG 60MAH4H9-SOG 60M46B3-SOGWO 60M49B3-SOGWO
Male
*The maximum pressure for an adapter coupling is determined by the connection component with the All dimensions for reference only and subject to change.
LOWEST pressure rating; that is, the two end connections and the tubing or pipe used, whichever is For prompt service, Parker Autoclave Engineers stocks select products. Consult your local representative.
LOWER. CAUTION: See appropriate pressure section in reference to proper selection of tubing.
In selecting an adapter involving two different sized connections, the larger connection should be on the
NOTE: All sour oil and gas valves and fittings supplied without collars and glands unless
male end where maximum the mechanical strength of the adapter.
otherwise specified.
18 All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold.
Sour Service Products - Severe Service Valve
Pressures to 10,000 psi (690 bar)
Maximum
Valve Working
Size Orifice Rated Pressure
(inches) inches (mm) Cv psi (bar)
Applications:
All areas where reliable shut-off is required in severe Aluminum Handle
All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold. 19
End Connection Dimensions - inches (mm)
Catalog Valve Pattern
Number Inlet Outlet A B C D E F G H J
N.P.T. N.P.T.
2-Way Straight
SSV71M4F4 1/4 male 1/4 Female 3.00 1.75 - 1.25 .625 3.25 3.41 0.75 2.50
(76.20) (44.45) - (31.75) (15.88) (82.55) (86.51) (19.05) (63.50)
1/4 Female 1/4 Female 3.00 1.50 - 1.25 0.63 3.25 3.41 0.75 2.50
SSV71F4
(76.20) (38.10) - (31.75) (15.88) (82.55) (86.51) (19.05) (63.50)
1/2 Male 1/2 Female 3.81 2.22 - 1.50 0.75 4.25 4.41 1.00 3.25
SSV71M8F8 See
(96.82) (56.34) - (38.10) (19.05) (107.95) (111.91) (25.40) (82.55)
1/2 Female 1/2 Female 3.81 1.91 - 1.50 0.75 4.25 4.41 1.00 3.25 Figure 1
SSV71F8
(96.82) (48.41) - (38.10) (19.05) (107.95) (111.91) (25.40) (82.55)
3/4 Male 3/4 Female 3.81 2.19 - 1.75 0.88 4.94 5.13 1.00 3.25
SSV71M12F12 (96.82) (55.55) - (44.45) (22.23) (125.40) (130.18) (25.40) (82.55)
3/4 Female 3/4 Female 3.81 1.91 - 1.75 0.88 4.94 5.13 1.00 3.25
SSV71F12
(96.82) (48.41) - (44.45) (22.23) (125.40) (130.18) (25.40) (82.55)
2-Way Angle
SSV72M4F4 1/4 Female 1/4 Male 3.75 1.63 1.16 1.25 0.63 3.25 3.41 0.75 2.50
(95.25) (41.28) (29.36) (31.75) (15.88) (82.55) (86.51) (19.05) (63.50)
1/4 Female 1/4 Female 3.00 1.63 1.16 1.25 0.63 3.25 3.41 0.75 2.50
SSV721F4
(76.20) (41.28) (29.63) (31.75) (15.88) (82.55) (86.51) (19.05) (63.50)
1/2 Female 1/2 Male 4.25 2.03 1.28 1.50 0.75 4.25 4.41 1.00 3.25
SSV72M8F8 See
(107.95) (51.59) (32.54) (38.10) (19.05) (107.95) (111.91) (25.40) (82.55)
1/2 Female 1/2 Female 3.81 2.00 1.28 1.50 0.75 4.25 4.41 1.00 3.25 Figure 2
SSV72F8
(96.82) (50.80) (32.54) (38.10) (19.05) (107.95) (111.91) (25.40) (82.55)
3/4 Female 3/4 Male 4.94 2.75 2.00 1.75 0.88 4.94 5.13 1.00 3.25
SSV72M12F12 (125.40) (69.85) (50.80) (44.45) (22.23) (125.40) (130.18) (25.40) (82.55)
3/4 Female 3/4 Female 4.50 2.75 2.00 1.75 0.88 4.94 5.13 1.00 3.25
SSV72F12
(114.30) (69.85) (50.80) (44.45) (22.23) (125.40) (130.18) (25.40) (82.55)
All dimensions for reference only and subject to change. All general terms and conditions of sale, including limitations of our liability,
For prompt service, Parker Autoclave Engineers stocks select products. apply to all products and service sold.
Consult factory.
Figure 1 Figure 2
G
Open
H
F (Diameter)
Closed
D
(Square)
E
C Inlet
Inlet B
A
20 All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold.
Sour Service Products - Pressure Gauges
Pressures to 20,000 psi (1379 bar)
All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold. 21
WARNING
FAILURE, IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS AND/OR SYSTEMS DESCRIBED HEREIN OR RELATED ITEMS CAN CAUSE DEATH, PERSONAL INJURY AND PROPERTY DAMAGE.
This document and other information from Parker Hannifin Corporation, its subsidiaries and authorized distributors provide product and/or system options for further investigation by users having technical
expertise. It is important that you analyze all aspects of your application and review the information concerning the product or system in the current product catalog. Due to the variety of operating conditions
and applications for these products or systems, the user, through its own analysis and testing, is solely responsible for making the final selection of the products and systems and assuring that all performance,
safety and warning requirements of the application are met. The products described herein, including without limitation, product features, specifications, designs, availability and pricing, are subject to change by
Parker Hannifin Corporation and its subsidiaries at any time without notice.
Offer of Sale
The items described in this document are available for sale by Parker Hannifin Corporation, its subsidiaries or its authorized distributors. Any sale contract entered by Parker will be governed by the provisions
stated in Parker's standard terms and conditions of sale (copy available upon request).
2013 Parker Hannifin Corporation | Autoclave Engineers is a registered trademark of the Parker Hannifin Corporation 02-0136SE January2013
Instrumentation Products Division Parker Hannifin Manufacturing Ltd. Caution! Parker Autoclave Engineers Valves, Fittings and Tools are
not designed to work with common commercial instrument tubing
Autoclave Engineers Operation Instrumentation Products Division, Europe
and will only work with tubing built to Parker Autoclave Engineers
8325 Hessinger Drive Industrial Estate Whitemill
AES Specifications. Failure to do so will void warranty.
Erie, Pennsylvania 16509-4679 USA Wexford, Republic of Ireland
PH: 814-860-5700 FAX: 814-860-5811 PH: 353 53 914 1566
www.autoclave.com FAX: 353 53 914 1582 ISO-9001 Certified
Tools, Installation, Operation
and Maintenance
Safe, efficient operation of any product is inherently
dependent upon its proper installation. In this section the
preparation and assembly of low, medium and high pres-
sure connections is explained. Also covered is the assembly
procedure for medium and high pressure anti-vibration collet
gland assemblies.
All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold.
www.autoclave.com 1
Tools, Installation, Operation and Maintenance - Installation
Parker Autoclave Engineers Speedbite Connections
Step 1 Step 2
Fitting Bite into tubing
exaggerated for clarity
Step 3 Step 4
2 All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold.
Tools, Installation, Operation and Maintenance - Manual Coning & Threading Tools
Manual Coning & Threading Tools
Parker Autoclave Engineers manufactures a manual coning appropriate die for any of the standard Parker Autoclave
and threading tool for optimum performance with tubing sizes Engineers tubing sizes through 9/16 (14.3 mm) outside
up to 9/16 (14.3 mm) outside diameter. These precision diameter. Interchangeable guide bushings properly guide the
quality manual tools permit on-site end preparation for Parker tool for accurate thread cutting.
Autoclave Engineers medium and high pressure tubing instal-
lations. One coning and one threading tool with optional sizes
of collets, blades dies and guide bushings eliminates the need
of multiple tools for different size tubing.
Interchangeable collets for each size tubing provides proper Coning Tool
centering of tubing. The cutting feed arrangement permits the
operator to control the length of the cut. Interchangeable tool
steel cutting blades are used in pairs to assure more accurate
and faster coning, and are designed to square-off and finish Cutter Support
the tube as the cone is completed. There is a provision for ap-
plying metal cutting lubricants to the cutting zone. Feed Nut
Tube Size Coning Tools and Components Catalog Number Threading Tools and Components Catalog Number
Tool Tool
Outside Inside Coning with Threading Die
Diameter with Guide
Diameter Blades Die & Tool
in.(mm) Collet & Bushing
in.(mm) Collet (set of 2) Bushing Only Order No. Size-type*
Blades
Parker AE Medium Pressure
1/4 (6.35) .109 (2.77) MCTM4 90248 101F-1577 402A 402 P-0214 1/4-28 1010-0343
3/8 (9.53) .203 (5.16) MCTM6 90250 101F-1601 402C 402 P-0215 3/8-24 1010-0344
9/16 (14.3) .312 (7.92) MCTM920 90251 1010-5218 402E 402 P-0216 9/16-18 1010-0345
9/16 (14.3) .359 (9.12) MCTM910 90251 101A-1897 402E 402 P-0216 9/16-18 1010-0345
1/4 (6.35) .083 (2.11) MCTH4 90248 101F-3939 402A 402 P-0214 1/4-28 1010-0343
Parker AE High Pressure
5/16 (7.92) .062 (1.57) MCTH5 90249 101F-3939 402B 402 P-0205 5/16-24 1030-0343
3/8 (9.53) .125 (3.18) MCTH6 90250 101F-1578 402C 402 P-0215 3/8-24 1010-0344
9/16 (14.3) .188 (4.78) MCTH960 90251 1010-0883 402E 402 P-0216 9/16-18 1010-0345
=9/16 (14.3) .250 (6.35) MCTH940 90251 101C-7214 402E 402 P-0216 9/16-18 1010-0345
* All threads for Parker AE medium pressure and high pressure tubing are LH national fine (class 2). = 9/16 (14.3) x .312 (7.92) ID 40,000 psi (2758 bar), use MCTM920.
Note: Manual coning and threading tools for 3/4" (19.1 mm) and 1" (25.4 mm) outside diameter medium pressure tubing are not available. Model AEGCTM-2 Power Coning-and-
Threading Machine is recommended for this tubing. A minimum of 3" (76 mm) straight length is required to perform coning and threading operation with manual coning tool.
All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold. 3
Tools, Installation, Operation and Maintenance - Coning, Coning & Threading Kits
Coning and Coning and Threading Tool Kits
Parker Autoclave Engineers offers coning kits as well as con-
ing and threading tool kits. Each kit consists of the required
tools, and other items necessary for your coning or coning
and threading needs. All kit items are placed in a hand-carry
tool case with top tray. The coning tools supplied in the tool
kits come complete with the vise stand and chip/oil reservoir
standard. The following is a list of items included in each kit.
Included with all kits: Coning tool assembly, three collets, col-
let nut wrench, three sets of coning blades, tool box with tray,
de-burring tool, one quart of cutting oil, 3/32 Allen wrench,
four spare set screws, and laminated instruction sheet.
Coning Kit:
Medium pressure kit
KMCT-M Coning tool with vise stand and reservoir
1/4, 3/8 and 9/16 collets
1/4, 3/8 and 9/16 blades
(9/16 blades for 20,000 psi tubing only)
4 All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold.
Tools, Installation, Operation and Maintenance - Coning & Threading Installation
Coning and Threading Installation
Manual Kit: 3. Fig. 2 Place the coning tool housing
Fig. 2
1. Fig. 1 Cut tubing to length and Fig. 1 (or optional support arm), without the
square off the end as close to the feed nut/cutter support assembly, in a
required length as possible. Allow extra vise. The vise should be equipped with
length for proper engagement into soft jaws, and the housing should be
the connection as listed in Table 1. A placed in the vise to allow lubricant to
small amount of extra length should flow to the cutters and cone.
be allowed to finish the end of the
tube, but excessive amounts require 4. Fig. 2 Slide the tubing through the
additional cutting time and premature collet until the end of the tube appears
blade wear. Note: When cutting tubing in the coning tool housing window. Line
with abrasive cut off wheel, tubing the end of the tube with the edge of the
should not be over heated effecting window and tighten the collet nut firmly in place using the collet nut wrench
material properties. (see Table 2).
2. Install the collet and collet nut into the bottom of the coning tool housing. 5. Fig. 3 Install the feed nut/cutter support assembly into the coning tool
Remove the cutter support feed nut from the coning tool housing and install housing. Rotate the feed nut clockwise until the top of the cutters just contact
the cutters. This can be done by backing out the four set screws in the cutter the top of the tube. Do not rotate the
Fig. 3
support. Note: When installing new blades, be sure the blades are flat against feed nut any further at this point.
the holder. There should be no space between the blades and the holder. 6. Fig. 3 Apply cutting oil through
the lubricant opening in the end of the
cutter holder or directly through the
Tube Connection Extra Allowance**
for Engagement housing window. A medium weight
Size Type high sulphur content cutting fluid is
inches (mm)
1/4 SF250CX 0.55 (13.97) recommended. Use the cutting oil
3/8 SF375CX 0.69 (17.53) freely during the coning operation.
Pressure
Medium
3/8 F375C 0.69 (17.53) of turns of the feed nut. The number of turns is listed in Table 2 under the
High
9/16 F562C 0.84 (21.34) heading Number of Turns. This includes enough advancement of the feed
9/16 F562C40 0.81 (20.57) nut to face off the tube. This assumes the tube is cut to length in accordance
1 F1000C-43 1.62 (41.1) with these instructions. The feed nut is supplied with a position indicator
** See Note on page 2. (drilled hole) to help determine the number of turns.
8. Rotate the handle in a clockwise direction while simultaneously slowly
turning the feed nut in a clockwise direction. Rotate the feed nut slowly and
evenly to smoothly cone the tube. Loosen collet nut, remove tubing and
visually inspect the cone. Use deburring tool to remove any burr on inside
WINDOW
edge of tube after coning.
CUTTER SUPPORT POSTION Fig. 4
HOUSING INDICATOR HANDLE
COLLET NUT SET SCREWS
Manual Threading:
COLLET
9. Fig. 4 Clamp the tubing in a soft
jaw vise. Do not over tighten. Slide the
TABLE 2
CUTTER
CUTTER SUPPORT
FEED NUT
threading tool over the tube through
Insert Tube to here
the guide bushing.
Medium Pressure Tubing High Pressure Tubing
10. Apply a medium weight, high
Cone Length No. of Tube O.D. Cone Length No. of
inches (mm) Turns (inches) inches (mm) Turns sulphur cutting oil to threading area.
1/4 0.11 (2.79) 2 1/4 0.13 (3.30) 3
3/8 0.13 (3.30) 3-1/2 5/16 0.19 (4.83) 3-1/2 Insert tube Guide
3/8 0.16 (4.06) 3 from this Bushing
9/16(CX-20) 0.16 (4.06) 3 direction
9/16 0.28 (7.11) 5-1/2
9/16(CX-10) 0.13 (3.30) 2-1/2 9/16(C40) 0.21 (5.33) 4-1/2
Manual coning and threading tools are not available for 3/4 and 1 tubing,
see page 13 Coning and Threading Machine.
All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold. 5
11. Apply pressure to the top of Approximate Number of Turns to Thread Tubing
the threading tool to start the
cutting action. The threads are Male Connection Number of Turns
left handed, so turn the threader
counterclockwise to thread the 59 SM250CX20 6-1/2
tube. The threading tool may need +0 D SM375CX20 7-1/2
to be periodically rotated clockwise -2 SM562CX20 6
to break and discharge metal chips.
SM562CX10 6-3/4
Apply lubricant freely during the L
threading process. Note: The lead M250C 12
in chamfer (larger chamfer) on the M312C150 12
die flutes toward guide bushing. M375C 14
12. Continue to rotate die holder counterclockwise while applying cutting oil M562C 12
generously throughout the process until threads of the following lengths have M562C40 13
been cut.
13. After tube is coned, threaded and deburred, check for proper thread fit and
Assembly and Makeup of Connection
length with a new collar of the proper size. Note: Rememebr to flush all tubing
prior to installation with a fluid that is compatiable with the process fluid being used. 1. Lubricate male threads of gland with a metal based thread
lubricant.= Slip gland on tubing as shown and thread collar on
Male Tube Size Dimensions Thread size*
tubing until one to two threads are exposed between collar and
inches (mm)
Connection Outside
Diameter
X
Inside
Diameter
and type cone.
Type D L (max)
(inches)
inches (mm)
SM250CX20 1/4 x 0.109 0.141 0.344 1/4 - 28 2. A small amount of process tolerable lubricant, such as
(6.35 x 2.77) (3.58) (8.74)
silicone grease, on the cone tip will help with the sealing
SM375CX20 3/8 x 0.203 0.25 0.438 3/8 - 24 process. Insert tubing in connection, engage gland and tighten
(9.53 x 5.16) (6.35) (11.13)
fingertight.
SM562CX20 9/16 x 0.312 0.406 0.500 9/16 - 18
(14.29 x 7.92) (10.31) (12.70)
3. Tighten gland with torque wrench to specified values on
SM562CX10 9/16 x 0.359 0.438 0.500 9/16 - 18
(14.29 x 9.12) (11.13) (12.70)
page 13. When tightening, the use of an additional wrench is
recommended to hold the fitting.
SM750CX20 3/4 x 0.438 0.562 0.625 3/4 - 16
(19.05 x 11.13) (14.27) (15.88)
= Copper Anti-Seize Lubricant:
SM750CX10 3/4 x 0.516 0.578 0.625 3/4 - 16
(19.05 x 13.11) (14.68) (15.88) P-3580 (1 pound can)
SM1000CX20 1 x 0.562 0.719 0.781 1 - 14 P-3580-8 (1/2 pound can)
(25.4 x 14.27) (18.26) (19.84)
Moly Anti-Seize Lubricant:
SM1000CX10 1 x 0.688 0.812 0.781 1 - 14 P-9766 (1 pound can)
TABLE 3
*Thread is left-hand national fine (Class 2). All dimensions for reference only
and subject to change. Completed Autoclave Engineers Completed Autoclave Engineers
Medium Pressure Connection. High Pressure Connection.
NOTE: M250C100 and M375C100 used in F312C150 connection at 100,000
psi (6895 bar).
6 All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold.
Tools, Installation, Operation and Maintenance - QSS Assembly Procedure
QSS Assembly Procedure
Fast, Positive Sealing for Pressures up to Torque values can be used for both initial setting and reas-
15,000 psi (1034 bar) sembly connections. See the following page for reassembly
1/4 & 3/8 Tubing Size (Standard setting operation) values and ranges.
See next page for setting with hydraulic tool. Initial setting torque
(Setting with hydraulic tool is recommended but not required). ft-lbs (NM)
1/4 40 (54.3)
1. Cut tubing to length and deburr. Allow extra length for
3/8 80 (108.5)
proper engagement (per table below).
Outside Diameter Extra Allowance** Completed Connection
Tube Size for Engagement
inches (mm) inches (mm) The illustration below shows the condition of sleeve and tub-
ing after completion of sleeve setting. The sleeve has cut
1/4 (6.35) 0.75 (19.05)
into the tubing as it moved forward into the tapered seat, up-
3/8 (9.53) 0.81 (20.64) setting material ahead of it and establishing a shoulder on the
2. Slip gland and sleeve onto tubing. tubing to provide positive mechanical support for the tubing
end-load. A properly set sleeve cannot be displaced back and
Note: Be sure to remove gland and sleeve from components forth along the tubing but may be rotated around the tubing.
and slide them onto the tubing before inserting the tubing into
the components.
Make sure larger end of sleeve is toward gland.
Push tubing into valve or fitting until it bottoms. Lubricate
gland nut threads to aid in assembly. If process tolerable, a
slight amount of inert grease on the nose of the compression
sleeve is recommended to improve sealability.
2. Slip gland nut and sleeve onto tubing. Lubricate the nose of
the compression sleeve or the tapered die surface with a metal to
metal lubricant. We recommend Jetlube MP-50. Make sure larger
end of sleeve is toward gland nut. Push tubing into hydraulic set
tool until it bottoms into the setting die. For the 1" size only, as- Step 3 Step 4
semble the split nut (2A-1) around the tubing between the sleeve
and gland with the larger counter bore towards the gland and
thread into the cap. Be sure both the split nut and cap have been
tightened down and neither can be moved by hand. The cap
should always be flush with the top of the housing (2A-2) while
the split nut will not. Skip step 3.
3. Thread gland nut into cap until the hex touches the top surface.
4. Pressurize cylinder up to the set pressure (per table below.)
DO NOT EXCEED THE SET PRESSURE. Step 5 Step 6
AS WITH ALL HIGH PRESSURE EQUIPMENT, USE CAUTION
DURING OPERATION. SET TOOL MAWP IS 10,000 PSI (690 BAR).
Outside Diameter Tube Size Set Pressure for Full Tubing Bite
inches (mm) psi (bar)
1/4 (6.35) 3/8 (9.53) 9/16 (14.27) 4500 (310) to 5000 (344)
3/4 (19.04) 8000 (552) to 10000 (690)
1 (25.4) 9000 (620) to 9500 (655)
The Parker Autoclave Engineers hydraulic sleeve set tool Tooling Installation and Changing Sizes
is designed for use with the QS Series glands, sleeves and To change tooling to another size only requires interchanging
Autoclave tubing. This tool is required to set the sleeve for 2 parts.
the 9/16 and 3/4 sizes and suggested for the 1/4 and 3/8
sizes. It not only produces the required bite into the tubing, it 1. Loosen the 5/16" set screw that locks the threaded cap from
is much easier than trying to set the sleeve the conventional rotating.
method. The tool comes in a self contained portable, lockable 2. Using a 5/32" hex key to rotate and remove the threaded
case complete with hand or air pump, cap and dies for all steel cap from the aluminum housing.
sizes. 3. Turn the tool assembly upside down to remove the die
from inside the housing.
4. Install the die of the appropriate connection size you wish
to use. The solid side of the die should be facing down
towards the hydraulic cylinder.
5. Install the appropriate size cap to match the size of the die.
Insert cap with the 5/32" hex up. Rotate with a 5/32" hex key
until it bottoms out on the shoulder side of the housing.
6. Thread in the 5/16" set screw until it bottoms out on the
cap threads. Tighten set screw to prevent movement
during use.
Ordering Information
HST-912: Complete tool kit with hand pump (shown in photo)
HST-912TW: Complete tool kit with torque wrench and adapters
Features HST-912A: Complete tool kit with air-operated pump (Air
Case Dimensions: 28W x 14.25H x 13.75D (711cm x operated pump #P-1948)
362cm x 292cm) HST-912ATW: Complete tool kit with torque wrench and adapters
Total Weight: 69 lbs. (31 Kg) HST-S: Complete table mounted system that includes everything in
Hand Pump: Single stage hydraulic (standard) the HST-912ATW plus the required tooling for the 1" size connections.
Hydraulic Cylinder: 10,000 psi, 2.5 25 ton Not shown. Consult factory for replacement parts.
Base & Housing: Aluminum anodized
Die and Cap: Precision hardened steel Description Part #
Gauge: 15,000 psi (1034 bar) Hydraulic Cylinder 90588
Air-operated hydraulic pump option can be furnished in Gauge 90594
place of standard hand pump. (Add -A to order number). Adapter 90593
Operating pressure 0 to 10,000 psi (0 to 690 bar). Base 101F-3407
Required air presssure, 30 psi (2.1 bar) minimum 120 Housing 101F-3408
psi (8.3 bar) maximum. Reservoir capacity: 24 cu. in. Hydraulic Pump P-1893
(393cm3). Air lubricator/air separator is recommended for Hose P-1894
air operated units. 3/4 Die HSTD12
9/16 Die HSTD9
Cap 3/4 Cap HSTC12
Die 9/16 Cap HSTC9
Tool Chest P-10011
Housing
Moly Paste P-9766
1/4 Die HSTD4
1/4 Cap HSTC4
3/8 Die HSTD6
3/8 Cap HSTC6
Hydraulic
Cylinder (TW) Kits with torque and adapters
Hose Connection
3/8 NPT 20 to 150 ft-lbs (27-203 Nm) Torque Wrench P-1680
75 to 250 ft-lbs (102-339 Nm) Torque Wrench 91020
5/8 wrench adapter P-1683
Base
3/4 wrench adapter P-9813
1-3/16 wrench adapter P-1689
1-1/2 wrench adapter P-6040
All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold. 9
Tools, Installation, Operation and Maintenance - Anti-Vibration Collet Gland
Anti-Vibration Collet Gland
Assembly Procedure
Anti-vibration collet gland assembly replaces the standard Collet
gland nut. Collet
Medium pressure Gland
1. Cone and thread tubing as defined on pages 5 and 6.
Series KCBGLX
2. Slide collet assembly onto tube and install collar as de- 20,000 psi (1379 bar) Collet
scribed in the assembly and makeup of connections on page Body
6. One or two threads should be exposed between the collar (Gland)
and cone.
1. Clamp fitting in soft-jawed vise. 5. Remove reamer, guide nut and bushing and inspect cone
seat.
2. Thread gland nut into connection and tighten to 10 ft. lbs.
(13.6 N.m). 6. Repeat steps 2,3,4 and 5, if necessary, until cone surface
has been restored and finish is smooth.
3. Apply a medium weight high sulfur cutting oil generously
through opening in nut. Cutting oil P-8784. 7. Clean fitting thoroughly to remove all chips and residue.
10 All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold.
Coning and Threading Machine
Benefits
Coning and Threading of Parker Autoclave Engineers
Medium and High Pressure Tubing.
All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold. 11
Coning and Threading Machine
AEGCTM-2G
AEGCTM-2E-CEG
AEGCTM-2GK Retrofit kit catalog number
Note: Detailed operational instructions are supplied with the
machine in two forms, printed and DVD. Refer to these instruc-
tions for tooling installation, machine adjustment, and maintenance
instructions.
12 All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold.
Torque Values
Special Material Connection Torque Table Pressure psi (bar) vs. Torque ft.-lbs. (N.m)
Note: Use the recommended torque value for special material valves and fittings based on the maximum allowable working pressure of the valve
or fitting
SF1000CX20 35 (47.5) 35 (47.5) 50 (67.8) 100 (135.6) 115 (156.0) 125 (169.5)
F1000C43 30 (40.7) 30 (40.7) 50 (67.8) 65 (88.1) 75 (101.7) 100 (135.6) 125 (169.5) 150 (203.3) 180 (244.0)
F250C 10 (13.6) 10 (13.6) 10 (13.6) 10 (13.6) 10 (13.6) 10 (13.6) 15 (20.3) 15 (20.3) 20 (27.1) 25 (33.9) 25 (33.9)
F375C 10 (13.6) 10 (13.6) 10 (13.6) 10 (13.6) 15 (20.3) 20 (27.1) 25 (33.9) 25 (33.9) 35 (47.5) 45 (61.0) 50 (67.8)
F562C 15 (20.3) 15 (20.3) 15 (20.3) 15 (20.3) 20 (27.1) 25 (33.9) 35 (47.5) 40 (54.2) 50 (67.86) 65 (88.1) 75 (101.7)
F562C40 15 (20.3) 15 (20.3) 15 (20.3) 15 (20.3) 25 (33.9) 30 (40.7) 40 (54.2) 45 (61.0) 60 (81.3)
14 All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold.
Tube Connection Dimensions
B
Thread
A Drill
F
C
Parker Autoclave SpeedBite SW* D
E
1/4 SW250 29/64 (11.5) 1/2 -20 0.34 (8.6) 0.44 (11.1) 0.69 (17.5) 0.34 (8.6) F 0.257 (6.5)
3/8 SW375 37/64 (14.7) 5/8 -18 0.38 (9.7) 0.47 (11.9) 0.75 (19.1) 0.48 (12.1) W 0.386 (9.8)
1/2 SW500 3/4 (19.1) 13/16 -16 0.41 (10.4) 0.50 (12.7) 0.81 (20.6) 0.60 (15.21) 0.514 (13.1)
B
Thread
Tube
Outside Connection Dimensions inches (mm) C
D
Diameter E
Type
(inches) A B C D E F G
1/16 W062
W125 Q 0.332 (8.4) 3/8 -24 0.22 (5.6) 0.31 (7.9) 0.47 (11.9) 0.19 (4.8) #30 0.128 (3.3)
1/8
G
1/4 W250 11/16 (17.4) 3/4 -16 0.38 (9.7) 0.44 (11.1) 0.69 (17.7) 0.35 (8.9) F 0.257 (6.5)
3/8 W375 11/16 (17.4) 3/4 -16 0.38 (9.7) 0.44 (11.1) 0.69 (17.7) 0.48 (12.1) W 0.386 (9.8)
QSS
Tube Dimensions inches (mm)
Outside Connection
Diameter Type
(inches) A B C D E F G
1/4 QSF250 29/64 (11.5) 1/2 -20 0.34 (8.6) 0.44 (11.1) 0.69 (17.5) 0.34 (8.6) F 0.257 (6.5)
3/8 QSF375 37/64 (14.7) 5/8 -18 0.38 (9.7) 0.47 (11.9) 0.75 (19.1) 0.48 (12.1) .038" (9.7)
9/16 QSF562 7/8 (22.2) 15/16 -16 0.57 (14.5) 0.704 (17.9) 1.25 (31.8) 0.712 (18.1) 0.57 (14.5)
3/4 QSF750 1-3/16 (30.15) 1-1/4 -18 0.83 (21.08) 1.00 (25.40) 1.56 (39.62) 0.95 (24.13) 0.76 (19.30)
1 QSF1000 1-9/16 (39.70) 1-5/8 -16 .75 (19.1) .88 (22.2) 1.56 (39.62) 1.24 (31.5) 1.02 (26.0)
Note: All dimensions are shown for reference only and should not be consid- For prompt service. Parker Autoclave Engineers stocks select products.
ered as actual machining dimensions. Consult factory. All general terms and conditions of sale, including limitations
of our liability, apply to all products and service sold.
*For port diameter please see orifice sizes for specific valves and fittings.
All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold. 15
Tube Connection Dimensions
B
1/4 SF250CX20 25/64 (9.9) 7/16 -20 0.28 (7.1) 0.50 (12.7) 0.19 (4.8) 0.109 (2.8) Thread
A
Drill
3/8 SF375CX20 33/64 (13.1) 9/16 -18 0.38 (9.7) 0.62 (15.7) 0.31 (7.9) 0.203 (5.2) F
C
9/16 *SF562CX10 3/4 (19.1) 13/16 -16 0.44 (11.1) 0.75 (19.1) 0.50 (12.7) 0.359 (9.1) D
SF562CX20 0.312 (7.9)
*SF750CX10 61/64 (24.2) 0.516 (13.1) 5
3/4 3/4 -14z 0.50 (12.7) 0.94 (23.9) 0.62 (15.7)
SF750CX20 0.438 (11.1)
Weep
*SF1000CX10 1-19/64 (32.9) 1-3/8 -12 0.81 (20.6) 1.31 (33.3) 0.88 (22.4) 0.688 (17.5) hole
1 H
SF1000CX20 0.562 (14.3)
1-1/2 SF1500CX 1.790 (45.47) 1-7/8 -12 1.00 (25.4) 1.594 (40.49) 1.375 (34.93) .937 (23.80) Z = NPS Male Tap
9/16 F562C40 1-3/64 (26.6) 1-1/8 -12 0.62 (15.7) 0.75 (19.1) 0.38 (9.7) 0.250 (6.4)
Weep
hole
5/16 F312C150 37/64 (14.7) 5/8 -18 0.62 (15.7) 1.06 (26.9) 0.25 (6.4) 0.094 (2.4) H
1 F1000C43 1-19/64 (32.9) 1-3/8 -12 0.81 (20.6) 1.31 (33.3) 0.88 (22.4) 0.438 (11.1)
Note: All dimensions are shown for reference only and should not be consid- For prompt service. Parker Autoclave Engineers stocks select products.
ered as actual machining dimensions. Consult factory.All general terms and conditions of sale, including limitations
of our liability, apply to all products and service sold.
*For port diameter please see orifice sizes for specific valves and fittings.
**For male tubing end preparation, please see pages 5 and 6.
16 All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold.
Hydraulic Tube Bender
For Single Pass Bending of High Pressure Tubing Minimum Bend (Mandrel) Radius
The Parker Autoclave Engineers hydraulic tube bender is Tube Size Minimum
Shoe*
designed to bend heavy wall tubing and provide fast, accurate Catalog Inches (mm) Rated
Minimum
Bend Inside
Length
Required 90
and reliable bending with only one setup. The tube bender is Number Outside Inside Pressure (bar) Radius
Inches (mm)
Bend
Inches (cm)
Diameter Diameter
complete with pump, cylinder, frame and bending shoes which
are self contained in a portable, lockable case. 201A-6016 9/16 (14.29) 0.359 (9.12) 15,000 (1034) 2.62 (66.5) 14 (35.6)
(Order number: HTB)
201A-6018 3/4 (19.05) 0.516 (13.11) 15,000 (1034) 3.50 (88.9) 16 (40.6)
201A-6014 1/4 (6.35) 0.109 (2.77) 20,000 (1379) 1.25 (31.8) 8 (20.3)
201A-6014 3/8 (9.53) 0.203 (5.16) 20,000 (1379) 1.75 (44.5) 8 (20.3)
201A-6016 9/16 (14.29) 0.312 (7.92) 20,000 (1379) 2.62 (66.5) 14 (35.6)
201A-6018 3/4 (19.05) 0.438 (11.13) 20,000 (1379) 3.50 (88.9) 16 (40.6)
201A-6014 1/4 (6.35) 0.083 (2.10) 60,000 (4137) 1.25 (31.8) 8 (20.3)
Features 201A-6014 3/8 (9.53) 0.125 (3.18) 60,000 (4137) 1.75 (44.5) 8 (20.3)
Dimensions: 27.5W x 14.0H x 14.0D (69.9cm x 35.6cm x
35.6cm). 201A-6016 9/16 (14.29) 0.250 (6.35) 40,000 (2758) 2.62 (66.5) 14 (35.6)
Weight: 55 lbs. (29.9 Kg)
201A-6016 9/16 (14.29) 0.188 (4.78) 60,000 (4137) 2.62 (66.5) 14 (35.6)
Single-stage hydraulic hand pump (standard)
Ram retractor valve relieves system pressure after bending. N/A** 5/16 (7.94) 0.062 (1.57) 150,000 (10342) 6.00 (152.4) 8 (20.3)
The spring loaded ram retracts for easy removal of tubing after
bending is completed. Annealed Parkre Autoclave Engineeers pressure tubing may also be bent on
HTB tube bender using bending shoe sizes specified above.
Quick release pivot pins lock and unlock easily for tube
removal. * HTB bending shoes are constructed of heat-treated aluminum alloy and
designed specifically for use with Parker Autoclave Engineers heavy wall
One-piece shoe locking pin locks bending shoe securely but stainless tubing. They are not intended for bending such components as com-
allows for quick release to interchange shoes. mercial pipe. Because of diameter differences, such misuse could fracture the
bending shoe.
Rugged bending frame is lightweight, aircraft quality, alumi-
num alloy. ** Information on bending 150,000 psi (10342 bar) tubing is included here for
reference only. This tubing should not be bent on HTB hydraulic tube bender
Precision one-piece bending shoes are permanent mold, because of the 6 required minimum radius.
heat-treated, aircraft quality, aluminum alloy.
Value shown is mimimum bend radius of the tubing; bending shoe furnished
Air-operated hydraulic pump option can be furnished in place (201A-6014) will bend tubing to 1.75 (44.5).
of standard hand pump. (Add -A to order number) Operating
pressure 0 to 10,000 psi (0 to 690 bar). Required air pres- Pressure rating of the bent tube will be reduced. Consult the Technical
Application section for pressure rating at various bend radii.
sure 30 psi (2.1 bar) minimum 120 psi ( 8.3 bar) maximum.
Reservoir capacity 24 cu. in. (393cm3). Available with optional All dimensions for reference only and subject to change.
hydraulic pressure gauge and gauge adapter. A lubricator/air
separator is recommended for air operated units.
All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold. 17
Tools, Installation, Operation and Maintenance - Lubrication Guide
Lubrication Guide
General Information
For reliable operation and long life of hand valves, air valves,
relief valves, check valves and safety heads, Parker Autoclave
Engineers strongly recommends proper lubrication of all
Metal to Metal
components that are subject to friction during assembly and / Lubricant
or operation. This is especially important where metal to metal
contact occurs such as on connection gland threads, packing
gland threads and stem threads. Without proper lubrication,
the high loads imposed on these threads may cause the parts O-ring
to weld (or gall) together from the high metal to metal contact Lubricant
forces and friction heat. Lubrication is also essential for the
effective sealing and long life of o-rings, especially those that
are used in dynamic sealing applications. The performance of
metal to metal seals will be improved with lubrication but, they
do not absolutely require it.
Lubrication Sites
1. Speedbite, Slimline and High Pressure Connections in
all valves and fittings - Prior to assembly, the connection
gland should be lubricated on the threads and on the area that Metal to Metal
is in contact with the sleeve or collar. Parker AE provides as Lubricant
18 All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold.
For piston type air operators, o-ring lubricant should be 1. Jet Lube SS-301 - This lubricant consists of pure copper
applied to the inside of the operator housing, on the center flakes that are homogenized into a non-melting, nonvolatile
rod and on all the o-rings, on the pistons and divider plates. viscous carrier. It is fortified with anti-oxidants, rust and cor-
On air-to-open diaphragm operators, the o-ring on the stem rosion inhibitors. Jet Lube SS-30 is the standard lubricant for
should be lubricated. The threads and end of the spring adjust- Parker Autoclave VFT components with sliding metal to metal
ment screw should be lubricated on all air-to-open valves. contact surfaces. The surfaces are copper coated and prevents
Refer to Figure 2 and 3 for lubrication sites on piston and seizure, galling and heat freeze. SS-30 comes in the form of
diaphragm style operators. a thick oil that can be easily brushed on the surfaces to be
4. Check Valves - The gland nut should be lubricated on the lubricated. The absolute service temperature range is from 0 to
external threads and at the end where it contacts the cover. 1800F (-17.8 to 982C). Jet Lube SS-30 is not recommended
The cover should be lubricated at the sealing surface where for extreme low temperature applications or processes that will
it contacts the body. For o-ring check valves, a small amount not tolerate the presence of copper.
of o-ring lubricant on the o-ring will help swell the elastomer 2. Jet Lube MP-50 Moly Paste1 - This is a thick paste that
and aid sealing. Refer to Figure 4 for lubrication sites on check contains molybdenum disulfide (MoS). This lubricant is
valves. suitable for preventing seizure and galling of parts at absolute
5. Relief Valves - Threads should be lubricated on the cap, temperatures of -300 to 750F (-184 to 399C). It is recom-
spring cylinder, adjustment bolt and on the seat gland. Refer mended for metal to metal components that are exposed to
to Figure 5 for lubrication sites on the relief valve. temperatures of less than 0F. Other lubricants may solidify
under these conditions and prevent the effective operation of
6. Safety Heads - The threads and end of the hold down nut dynamic components.
should be lubricated. Refer to figure 6 for lubrication sites on
the safety head. 3. DuPont Krytox 240AC2 - Krytox is a non-flammable
fluorinated grease used for metal to metal lubrication in valves
For any part not covered in the above statements, the general that are cleaned and designated for oxygen service. It comes
rule is that parts that will move against each other during in the form of a white grease and has a recommended absolute
assembly or operation should be lubricated at the points/areas service temperature range of -15 to 500F (-26.1 to 260C).
of contact.
4. Molycoat 55M4 (Dow Corning) - This grease is used for
static lubrication between rubber and metal parts in ball valves
Recommended Lubricants and o-ring check valves. It is a silicone based lubricant and
Note: This information is provided for reference only. The meets Military Specifications MIL-G-4343. It is not recom-
manufacture of the lubricant should be contacted for specific mended for use on silicone rubber o-rings and seals. It has
information based on your application. Refer to the material a recommended absolute service temperature range of
safety data sheets for information on safe usage and storage -85 to 350F (-65 to 177C).
methods for these lubricants. 5. Neolube DAG 1563 - This is a dry film lubricant for valves
used in Navy Nuclear service. It consists of graphite particles
in a thermoplastic resin and ispropanol and meets Military
Specification MIL-L-24131B. The dry film form allows tight
control of impurities that are required for these applications.
It has an absolute service temperature of -100 to 400F.
6. LubriPlate-NSF H-1 Registered, Extremely Tacky, Food
Grade Greases - This grease is used for dynamic lubrication
between rubber and metal parts in pneumatic systems such
as piston style air operators. A tacky, adhesive, highly water
resistant grease for medium to slow dynamic speeds. It has
a recommended absolute service temperature range of
-0 to 350F (-17.8 tp 177C).
Metal to Metal
Lubricant
O-ring
Figure 3 Lubricant
Air Valve (Diaphragm) Figure 4
Lubrication Sites Check Valve
Lubrication Sites
All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold. 19
Tools, Installation, Operation and Maintenance - Lubrication Guide
Services
For service, contact the Parker Autoclave Engineers Representative in your area, or FAX Parker Autoclave Engineers Customer
Support Services at 1-814-860-5703.
Metal to
Metal to Metal Metal Lubricant
Lubricant
Metal to Metal
Seal Surface Lubricant
Figure 5 Figure 6
Relief Valve Safety Head
Lubrication Sites Lubrication Sites
WARNING
FAILURE, IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS AND/OR SYSTEMS DESCRIBED HEREIN OR RELATED ITEMS CAN CAUSE DEATH, PERSONAL INJURY AND PROPERTY DAMAGE.
This document and other information from Parker Hannifin Corporation, its subsidiaries and authorized distributors provide product and/or system options for further investigation by users having technical
expertise. It is important that you analyze all aspects of your application and review the information concerning the product or system in the current product catalog. Due to the variety of operating conditions
and applications for these products or systems, the user, through its own analysis and testing, is solely responsible for making the final selection of the products and systems and assuring that all performance,
safety and warning requirements of the application are met. The products described herein, including without limitation, product features, specifications, designs, availability and pricing, are subject to change by
Parker Hannifin Corporation and its subsidiaries at any time without notice.
Offer of Sale
The items described in this document are available for sale by Parker Hannifin Corporation, its subsidiaries or its authorized distributors. Any sale contract entered by Parker will be governed by the provisions
stated in Parker's standard terms and conditions of sale (copy available upon request).
2013 Parker Hannifin Corporation | Autoclave Engineers is a registered trademark of the Parker Hannifin Corporation 02-0140SE January2013
Instrumentation Products Division Parker Hannifin Manufacturing Ltd. Caution! Parker Autoclave Engineers Valves, Fittings and Tools are
not designed to work with common commercial instrument tubing
Autoclave Engineers Operation Instrumentation Products Division, Europe
and will only work with tubing built to Parker Autoclave Engineers
8325 Hessinger Drive Industrial Estate Whitemill
AES Specifications. Failure to do so will void warranty.
Erie, Pennsylvania 16509-4679 USA Wexford, Republic of Ireland
PH: 814-860-5700 FAX: 814-860-5811 PH: 353 53 914 1566
www.autoclave.com FAX: 353 53 914 1582 ISO-9001 Certified
Technical Information
The information presented in this section is intended to assist
designers in the proper selection of Parker Autoclave Engi-
neers valves, fittings and tubing for fluid handling systems.
This technical data does not represent product specifications
but rather guidelines for direction in the proper application
of the referenced equipment. These guidelines are general in
nature because of the many process variables.
Technical Information
All general terms and conditions of sale, including limitations of our liability,www.autoclave.com
apply to all products and services sold.
www.autoclave.com 1
Technical Information - General Information
Technical and Application Information
Materials:
Widely varying conditions frequently require that valves, ing material for the majority of extremely high temperature
fittings and tubing be constructed of materials other than con- applications, some gases may permeate more readily through
ventional stainless steel. Since many variables affect the corro- graphite yarn packing than through the PTFE packing in a valve
sion resistance of metallic materials, it is Parker Autoclave with an extended stuffing box. The packing material must be
Engineers policy not to recommend materials based on kept below the maximum permitted temperature listed on
corrosion resistance for specific fluid applications. We can, page 5.
however, suggest materials based on mechanical strength and
Valve Stem Seating:
also indicate materials generally used in a specific application.
Other materials not listed in this section are also available. Abrasive flow or high cycle service will require more frequent
maintenance. Special materials and the proper valve series
Pressure: selection may extend service life. For example, if flow is not
Included in this section are the standard pressure ratings for critical, a 30VM valve with an N-Dura stem will require less
several common materials for valves and fittings as well as maintenance than an SW series valve used in a low pressure,
tubing. Parker Autoclave Engineers stocks a select quantity of high cycle, abrasive flow application. Although all application
special material tubing for immediate delivery. parameters cannot be considered in this section, the user can
generally expect several thousand cycles in a liquid application
Temperature: and several hundred cycles for gas service. The packing gland
Also contained in this section are pressure reduction factors may require adjustment, however, to achieve these results.
at various temperatures for several materials. To obtain the
maximum pressure rating at an elevated temperature, multiply Pressure Cycling:
the maximum pressure rating of the item at room temperature In medium and high pressure applications, static as well as
by the elevated temperature factor (% of RT). dynamic (cyclic) pressure must be considered when selecting
High and low temperatures or high heat up and/or cool down an appropriate valve series. If fatigue life is a concern, Parker
rates can affect the capability of a metal-to-metal seal. When Autoclave Engineers can supply tubing which has been auto-
selecting a valve series, consideration should not only be given frettaged for improved fatigue resistance. For internally pres-
to static pressure rating, but also static and dynamic surized tubing, autofrettaging is a method by which the inner
temperature conditions. Generally, the smaller the seal diam- wall of the tube is precompressed to reduce the tube operating
eter of a metal-to-metal seal, the more reliable the seal will be. bore stresses. By applying sufficient internal pressure, greater
than the maximum working pressure of the tube, the inner wall
Gas or Liquid Service: is plastically deformed by a controlled amount. The remain-
Light gases such as hydrogen and helium are more difficult to ing outer portion of the wall acts elastically, and when the
seal than liquids. When selecting a valve series, consideration pressure is released, a positive compressive load at the bore
should be given to the fluid application and not just pressure will exist. As mentioned previously, the result is reduced bore
and temperature requirements. The higher the rating of the stress and increased fatigue life. In addition to the autofrettag-
valve or fitting, the less the likelihood of weepage problems ing method to increase cycle life, Parker Autoclave Engineers
with light gases. Tubing selections should also consider the offers HP-HC (high-pressure high cycle) tubing, rated to
service requirements, since thicker wall, smaller outside 100,000 psi (6895 bar). This tubing can be substituted for our
diameter tube sizes will produce a more reliable connection standard 60,000 psi (4137 bar) tubing providing longer life at
seal. Handling of fittings and tubing during installation will 60,000 psi (4137 bar) operation.
make a difference in sealability of light gases as well as liquids. Vacuum Service:
Do not handle the tube or fitting in such a way as to damage
the sealing surfaces. If it is process tolerable, a small amount The high, medium and low pressure series of Parker Autoclave
of lubrication (or even process fluid) on the seal area during Engineers standard valves, fittings and tubing can be used in
installation will help the sealing process. Refer to the Tools, light vacuum services to 10-2 torr. For high vacuums to 10-5 or
Installation, Operation and Maintenance section for further 10-6 torr, Parker Autoclave Engineers high pressure series is
information. recommended. Extreme care and proper seal lubrication is re-
quired (as mentioned in the Gas or Liquid Service paragraph)
Valve Stem Packing Materials: to achieve these degrees of vacuum. The pump type and size
The considerations listed thus far should be applied when will determine the final vacuum pressure.
selecting a suitable valve stem packing material (PTFE, PTFE
glass or Graphite yarn). Where possible, PTFE packing is the
most reliable, low maintenance, packing choice; PTFE/glass is
the second. While graphite yarn packing is a reliable pack-
2 All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold.
Technical Information - Coned & Threaded Connections
Parker Autoclave Engineers Medium & High Pressure Coned and Threaded Connections
Features:
Pressures to 20,000 psi (1379 bar)
Uncompromised reliability under rigorous thermal and Gland
Features:
Pressures to 60,000 psi (4137 bar)
Increased pressure handling capabilities Gland
Collar
Uncompromised reliability under rigorous thermal and Valve or Fitting
Body
pressure cycling Cold-worked
Tubing
Well suited to installations which require repeated assembly
and disassembly with consistent reliability.
Available in tube outside diameter sizes of 1/4 (6.35mm),
3/8(9.53mm) and 9/16(14.27mm) and bore sizes of
.083(2.11mm), .125(3.18mm), .188(4.78mm) and
.250(6.35mm).
Line-contact
Positive Backup
Sealing
Support
All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold. 3
Technical Information - Coned and Threaded Connections
Design Considerations - Why Coning and threading?
Positive backup support occurs with the collar threaded Because of the threaded on collar design, Parker Autoclave
(left-handed) directly onto the tubing to form a positive Engineers' Medium and High-Pressure connections can take
integral retaining surface. This allows for a consistent repeated thermal cycling under pressure with no loss in reli-
connection make up that is required at higher pressures and ability. These connections can also handle a wider range of
temperatures. When the gland nut is threaded into the temperatures than swaged or bite type connections and are
connection, the tubing is locked securely in place and the designed to maintain integrity from -423F to 1200F (-252C
possibility for the ejection of the tubing from a properly to 649C).
assembled and used connection is extremely remote. Pre-Rated Systems:
Remarks: Valves, fittings and tubing with Parker Autoclave Engineers'
Since the glands and threaded collars can be removed from Medium and High-Pressure connections provide a fully engi-
the tubing, properly lubricated Parker Autoclave Engineers neered, pre-rated system of components that are interchange-
Medium-Pressure and High-Pressure connections can be dis- able from assembly to assembly. They are not over sensitive to
assembled and reassembled repeatedly without loss of relabil- abuse or careless assembly and no special gauges or tools are
ity. These connections are used with cold-worked valve and needed to check the connection. Weep holes are provided in
fitting bodies which can withstand many repeated sealings. every connection to permit fast visual inspection for leakage,
Therefore, valves, fittings and accessories can be inserted or and prevent pressure build up in the threads.
removed from the pressure system or the system can be Materials:
altered or expanded in a fraction of the time and cost that may
Parker Autoclave Engineers' standard gland and collar material
be imposed by welded, screwed, flared or other types of
is type 316 cold-worked stainless steel. This material provides
connections.
high strength and good impact resistance over the tempera-
ture range mentioned above. A bonded dry film lubricant, to be
used as an anti-galling agent, is available.
Pipe Thread Information
In some applications pipe threads may be preferred in place NOTE: NPT (Pipe) connections
of standard Parker Autoclave Engineers connections. Pipe NPT threads must be sealed using a high quality PTFE tape and/or
PTFE paste product. Refer to thread sealant manufacturers instructions
threads for pressure seals are tapered or combination of on how to apply thread sealant.
taper and straight. A number of factors apply to pipe threads Sealing performance may vary based on many factors such as pressure,
for high-pressure sealing. Thread form or the quality of the temperature, media, thread quality, thread material, proper thread
engagement and proper use of thread sealant.
thread, which refers to the gauging or thread dimensions. Customer should limit the number of times an NPT fitting is assembled
Another is the actual machining of the thread producing the and disassembled because thread deformation during assembly will
required finish to prevent thread galling. result in deteriorating seal quality over time. When using only PTFE tape,
consider using thread lubrication to prevent galling of mating parts.
Pipe threads can be used up to 15,000 psi (1034 bar) safely
if proper installation procedures are followed. The following Temperature limitations for pipe threads are based on material
should be adhered to when using pipe threads. strength and thread sealant. Parker Autoclave Engineers limits
its pipe thread components to 0F (17.8C) to 400F (204C)
and pressures as stated in the components sections.
4 All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold.
Technical Information - Pressure/Temperature Rating Guide
Pressure/temperature Rating Guide
Information in this rating guide is furnished to approximate the Refer to appropriate tubing section for pressure ratings of
pressure/temperature capabilities of Parker Autoclave standard Parker Autoclave Engineers' tubing at various tem-
Engineers valves and fittings with various options. peratures to 800F (427C).
Note maximum temperature ratings for Parker Autoclave
To determine approximate ratings, the following factors should Engineers' valves with various packing and stem options in
be considered: table below.
Refer to valve or fitting ordering pages for the base pressure Note pressure/temperature curve on page 6 for type 316
rating of component at room temperature (R.T.). stainless steel bodies and tubing.
Refer to Technical Information section for pressure ratings of Note temperature information checklist on page 6.
materials at elevated temperatures.
10V Vee or Reg., Metal-to-Metal -100 (-73) 450 (232) NA NA -100 (-73) 600 (316) 0 (-17.8) 8002 (427)
SW Vee or Reg., Metal-to-Metal -100 (-73) 450 (232) NA NA -100 (-73) 600 (316) 0 (-17.8) 8002 (427)
10SM/20SM Vee or Reg., Metal-to-Metal -100 (-73) 450 (232) NA NA -100 (-73) 600 (316) 0 (-17.8) 800 (427)
30SC Vee or Reg., Metal-to-Metal -100 (-73) 450 (232) NA NA -100 (-73) 600 (316) NA NA
30VM Vee or Reg., Metal-to-Metal -100 (-73) 450 (232) NA NA -100 (-73) 600 (316) 0 (-17.8) 800 (427)
See page 2
40VM Vee or Reg., Metal-to-Metal NA NA 40 (4.4) 230 (110) -100 (-73) 600 (316) 0 (-17.8) 800 (427) of Extreme Tem-
perature Series
60VM Vee or Reg., Metal-to-Metal NA NA 40 (4.4) 230 (110) -100 (-73) 600 (316) 0 (-17.8) 800 (427)
Needle Valve
100VM Vee Stem, Metal-to-Metal NA NA 40 (4.4) 230 (110) NA NA NA NA Section
for information
15Y Vee or Reg., Metal-to-Metal -100 (-73) 450 (232) NA NA -100 (-73) 600 (316) 0 (-17.8) 800 (427) on extended
stuffing box.
50Y Vee or Reg., Metal-to-Metal -100 (-73) 450 (232) NA NA NA NA 0 (-17.8) 800 (427)
10VRMM Micrometering -100 (-73) 450 (232) NA NA -100 (-73) 600 (316) 0 (-17.8) 8002 (427)
30VRMM Micrometering -100 (-73) 450 (232) NA NA -100 (-73) 600 (316) 0 (-17.8) 800 (427)
60VRMM Micrometering NA NA 40 (4.4) 230 (110) -100 (-73) 600 (316) 0 (-17.8) 800 (427)
Caution: While testing has shown O-rings to provide satisfactory 3. Compression sleeve-type connections such as Parker Autoclave
service life, both cyclic and shelf life may vary widely with differing Engineers UniVersaLok, Parker Autoclave Engineers SpeedBite or
service conditions, properties of reactants, pressure and temperature other swaged or bite-type connections are not recommended for ser-
cycling and age of the O-ring. FREQUENT INSPECTION SHOULD BE vice above 650F (343C) or below 0F (-17.8C). For such applica-
MADE to detect any deterioration, and O-rings replaced as required. tions, Parker Autoclave Engineers recommends its medium pressure
components with Parker Autoclave Engineers Medium Pressure
Note: coned-and -threaded connections, offering excellent thermal cycling
1. Optional graphite-yarn packing not recommended for hydrogen or capability.
helium service.
2. 40VM, 60VM and 60VRMM valves use Peak/PTFE/Peak for the 4. Pressure Limitations: Consult factory on 3/4 and 1 inch sizes.
PTFE glass option.
All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold. 5
Pressure/Temperature Rating Curve: 316 SS & 304 SS
100%
80%
This curve illustrates maximum working pressure for
70% Type 316 stainless steel tubing, valve and fitting bodies at
various temperatures to 1200F (649C) expressed as
% of Rated Pressure @ R.T.
40%
20%
10%
0%
0 100 200 300 400 500 600 700 800 900 1000 1100 1200
(38) (93) (149) (204) (260) (316) (371) (427) (482) (538) (593) (649)
Temperature in F (C)
Note:
Curves and ratings presented here are average values for reference only, * Curve is valid for cold-worked Type 316 stainless steel components
and can be significantly affected by pressure and temperature character- as long as operating temperature does not exceed 800F (427C). When
istics of trim and packing materials. For unusual pressure/temperature exceeding this temperature, the cold worked effect is PERMANENTLY
requirements, please consult factory for recommended body, trim and altered, and the components should be considered as annealed material,
packing specifications. using 40% of its cold-worked rating for future operation of the compo-
For pressure temperature information on components supplied in materi- nents.
als other than Type 316 stainless steel, refer to pages 9-10.
Coned-and-Threaded
Required Recommended Recommended Required Required
Connections
For prompt service, Parker Autoclavce Engineers stocks select products. Consult factory.
6 All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold.
Technical Information - Material vs. Pressure Rating
Parker Autocalve Engineers Valves, Fittings and Tubing
Valves & Fittings
Tube Material vs. Pressure Rating psi (bar) @ Room Temperature *
Valve Connection
Size
Series Type
(in.) 316CW (Std.) Hastelloy C276 Inconel 600 Inconel 625 Monel 400 Nickel 200 Titanium Gr2 Titanium 6AL4V
W125 1/8 15,000 (1034) 11,000 (758) 11,000 (758) 11,000 (758) 9,900 (683) 6,000 (414) 7,500 (531) 11,000 (758)
W250 1/4 15,000 (1034) 11,500 (793) 11,500 (793) 11,500 (793) 9,900 (683) 6,000 (414) 7,500 (531)) 11,500 (793)
10V
W375 3/8 15,000 (1034) 7,500 (517) 7,500 (517) 7,500 (517) 6,300 (434) 3,800 (262) 4,800 (331) 7,500 (517)
W500 1/2 10,000 (690) 5,500 (379) 5,500 (379) 5,500 (379) 4,600 (317) 2,700 (186) 3,400 (234) 5,500 (379)
SW250 1/4 15,000 (1034) 9,600 (662) 7,700 (531) 12,500 (862) 6,300 (434) 3,800 (262) 4,800 (331) 11,500 (793)
SW SW375 3/8 15,000 (1034) 7,500 (517) 7,500 (517) 7,500 (517) 6,300 (434) 3,800 (262) 4,800 (331) 7,500 (517)
SW500 1/2 10,000 (690) 5,500 (379) 5,500 (379) 5,500 (379) 4,600 (317) 2,700 (186) 3,400 (234) 5,500 (379)
SF562CX10 9/16 10,000 (690) 10,000 (690) 9,300 (641) 10,000 (690) 6,600 (455) 4,000 (276) 6,600 (455) 10,000 (690)
10SM SF70CX10 3/4 10,000 (690) 10,000 (690) 9,300 (641) 10,000 (690) 6,600 (455) 4,000 (276) 6,600 (455) 10,000 (690)
SF1000CX10 1 10,000 (690) 10,000 (690) 9,300 (641) 10,000 (690) 6,600 (455) 4,000 (276) 6,600 (455) 10,000 (690)
SF250CX 1/4 20,000 (1379) 12,200 (841) 9,300 (641) 15,000 (1034) 6,600 (455) 4,000 (276) 6,600 (455) 20,000 (1379)
SF375CX 3/8 20,000 (1379) 12,200 (841) 9,300 (641) 15,000 (1034) 6,600 (455) 4,000 (276) 6,600 (455) 20,000 (1379)
20SM SF562CX20 9/16 20,000 (1379) 12,200 (841) 15,000 (1034) 20,000 (1379)
SF750CX20 3/4 20,000 (1379) 12,200 (841) 15,000 (1034) 20,000 (1379)
SF1000CX20 1 20,000 (1379) 12,200 (841) 15,000 (1034) 20,000 (1379)
F250C 1/4 30,000 (2068) 22,400 (1544) 17,300 (1193) 22,500 (1551) 13,000 (896) 8,200 (565) 15,200 (1048) 30,000 (2068)
30VM F375C 3/8 30,000 (2068) 22,400 (1544) 17,300 (1193) 22,500 (1551) 13,000 (896) 8,200 (565) 15,200 (1048) 30,000 (2068)
F562C 9/16 30,000 (2068) 22,400 (1544) 17,300 (1193) 22,500 (1551) 13,000 (896) 8,200 (565) 15,200 (1048) 30,000 (2068)
40VM F562C40 9/16 40,000 (2758) 23,500 (1620) 18,400 (1269) 27,000 (1862) 13,800 (951) 8,700 (600) 16,200 (1117) 40,000 (2758)
F250C 1/4 60,000 (4137) 35,900 (2475) 27,700 (1910) 35,900 (2475) 20,800 (1434) 13,100 (903) 24,300 (1675) 60,000 (4137)
60VM F375C 3/8 60,000 (4137) 35,900 (2475) 27,700 (1910) 35,900 (2475) 20,800 (1434) 13,100 (903) 24,300 (1675) 60,000 (4137)
F562C 9/16 60,000 (4137) 35,900 (2475) 27,700 (1910) 35,900 (2475) 20,800 (1434) 13,100 (903) 24,300 (1675) 60,000 (4137)
* For ratings at elevated temperatures see P/T Rating Curves on pages 9 and 10. Tubing, connection type and/or packing material may limit maximum temperature rating.
See pages 5 and 6 for further temperature limitations.
uUse 10SM Series
Note: Hastelloy C276 values for SW are based on the valve ratings.
The tubing pressure rating in some instances is lower than the rating of the valve and Except low pressure series which is 316 annealed.
fitting. Tubing connection type and/or packing material may limit maximum temperature * For ratings at elevated temperatures see P/T Rating Curves on pages 9 & 10.
rating. See pages 5 & 6 for further temperature limitations. ** Except Hastelloy C276 which is welded and drawn or seamless.
All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold. 7
Tubing (Seamless) - Low Pressure** - continued
Tubing Size Material vs. Pressure Rating psi (bar) @ Room Temperature *
Valve Outside x Inside
Series Diameter
Inches (mm) 316CW Hastelloy C276 Inconel 600 Inconel 625 Monel 400 Nickel 200 Titanium Gr2
3/8 x 0.195 10,000 10,000 10,000 7,500 8,800 5,300 6,600
(9.53 x 4.95) (689.46) (689.46) (689.46) (517.10) (606.73) (365.42) (455.05)
3/8 x 0.250 7,500 7,500 7,500 7,500 6,300 3,800 4,800
(9.53 x 6.35) (517.10) 517.10) (517.10) (517.10) (434.36) (262.00) (330.94)
Low Pressure
The tubing pressure rating in some instances is lower than the rating of the valve and Except low pressure sereis which is 316 annealed.
fitting. Tubing connection type and/or packing material may limit maximum temperature * For ratings at elevated temperatures see P/T Rating Curves on pages 9 & 10.
rating. See pages 5 & 6 for further temperature limitations. ** Except Hastelloy C276 which is welded and drawn or seamless.
The tubing pressure rating in some instances is lower than the rating of the valve and Except low pressure series which is 316 annealed.
fitting. Tubing connection type and/or packing material may limit maximum temperature * For ratings at elevated temperatures see P/T Rating Curves on pages 9 & 10.
rating. See pages 5 & 6 for further temperature limitations.
8 All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold.
Technical Information - Pressure vs. Temperature Rating Curves
Inconel 600
100
90
70
60
50
40
30
20
10
0
100 200 300 400 500 600 700 800 900 1000 1100 1200
(38) (93) (149) (204) (260) (316) (371) (427) (482) (538) (593) (649)
Temperature in F (C)
Example: What would be the pressure rating of a 30VM 1/4 inch valve
constructed of Hastelloy C276 at 600F (316C)?
From the Material vs. Pressure rating chart on pages 7 & 8 for valves and
fittings, the maximum pressure rating for a 30VM 1/4 inch valve constructed
of Hastelloy C276 would be 22,400 psi (1544 bar).
To determine the approximate pressure rating at 600F (316C), the Pressure
vs. Temperature Rating Curves will be used. A vertical line on the x-axis
(Temperature) is traced at 600F (316C) [on the Hastelloy C276 graph], until
it intersects the curve. A horizontal line is then drawn to the y-axis (% of rated
pressure @ RT) and read as 93%. The room temperature rating of the
Hastelloy C276 valve is multiplied by the temperature reduction factor (.93)
22,400 psi (1544 bar) to approximate the temperature corrected pressure of
20,800 psi (1434 bar).
See page 5 for further packing temperature limitations.
Curves and ratings presented here are average values for reference only and
can be significantly affected by pressure and temperature characteristics of
trim materials, stem packing materials (or o-rings), and connection type.
Other options such as an extended stuffing box will be required to achieve
the maximum temperature rating. See pages 5 and 6 for further temperature
limitations. For unusual pressure/temperature requirements, please consult
factory for recommended body, trim and packing specifications.
To obtain the maximum pressure rating at an elevated temperature, multiply
the maximum pressure rating of the item (in special material) at room
temperature, by the elevated temperature factor (% of RT).
All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold. 9
Technical Information - Pressure vs. Temperature Rating Curves
90 90
% of Room Temperature Rating
70 70
60 60
50 50
40 40
30 30
20 20
10 10
0 0
100 200 300 400 500 600 700 800 900 1000 1100 1200 100 200 300 400 500 600 700 800 900 1000 1100 1200
(38) (93) (149) (204) (260) (316) (371) (427) (482) (538) (593) (649) (38) (93) (149) (204) (260) (316) (371) (427) (482) (538) (593) (649)
90 90
% of Room Temperature Rating
80 80
70 70
60 60
50 50
40 40
30 30
20 20
10 10
0 0
100 200 300 400 500 600 700 800 900 1000 1100 1200 100 200 300 400 500 600 700 800 900 1000 1100 1200
(38) (93) (149) (204) (260) (316) (371) (427) (482) (538) (593) (649) (38) (93) (149) (204) (260) (316) (371) (427) (482) (538) (593) (649)
Curves and ratings presented here are average values for reference only and Example: What would be the pressure rating of a 30VM 1/4 inch valve
can be significantly affected by pressure and temperature characteristics of constructed of Titanium Grade 2 at 600F (316C)?
trim materials, stem packing materials (or o-rings), and connection type. From the Material vs. Pressure rating chart on pages 7 & 8 for valves and
Other options such as an extended stuffing box will be required to achieve fittings, the maximum pressure rating for a 30VM 1/4 inch valve constructed
the maximum temperature rating. See pages 5 and 6 for further temperature of Titanium Grade 2 would be 15,200 psi (1048 bar).
limitations. For unusual pressure/temperature requirements, please consult To determine the approximate pressure rating at 600F (316C), the Pressure
factory for recommended body, trim and packing specifications. vs. Temperature Rating Curves will be used. A vertical line on the x-axis
To obtain the maximum pressure rating at an elevated temperature, multiply Temperature) is traced at 600F (316C) [on the Titanium Grade 2 graph],
the maximum pressure rating of the item (in special material) at room tem- until it intersects the curve. A horizontal line is then drawn to the y-axis
perature, by the elevated temperature factor (% of RT). (% of rated pressure @ RT) and read as 44%. The room temperature rating
of the Titanium Grade 2 valve is multiplied by the temperature reduction factor
(.44) 15,200 psi (1048 bar) to approximate the temperature corrected pressure
of 6,688 psi (461 bar).
See page 5 for further packing temperature limitations.
10 All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold.
Technical Information - Flow Calculations
Liquids & Gases
Coefficient of flow (Cv) for a valve is the volume of water, in Flow Formulas
U.S gallons per minute at room temperature, which will flow
through the valve with the stem fully open with a pressure Liquids
drop of 1 psi (.069 bar) across the valve. Cv is the valve sizing Flow, U.S. gal./min.
factor that permits selection of the appropriate valve to meet V = Cv P1 - P2
flow requirements of a given fluid system
SGF
The flow capacity curves presented in the ordering pages for
each series of Parker Autoclave Engineers valves show the Cv Flow, lb./hr.
for all series, sizes and stem types per number of turns of the V = 500 Cv (P1 - P2) /SGF
stem. These curves also illustrate the relative flow patterns for
a vee on-off stem and a regulating stem. Gases
Flow, SCFH
The Cv values shown on the valve ordering pages represent *
the full-open Cv for that valve. In determining estimated capac- Q = 42.2 Cv (P1 - P2) (P1 + P2)
ity, this Cv value should be used in the formulas which follow. SGF
Flow, SCFH (temperature corrected)
Q = 963 Cv (P1 - P2) (P1 + P2)
SG TF
Flow, lb./hr.
W = 3.22 Cv (P1 - P2) (P1 + P2)/ SG
Saturated Steam
Flow, lb./hr.
W = 2.1 Cv (P1 - P2) (P1 + P2)
Formula Nomenclature
For 2 way angle patterns, increase Cv value 50% V = Flow, U.S. gallons per minute (GPM)
Q = Flow, standard cu.ft. per hr. (SCFH)
Specific Gravity (Sg) Specific Gravity (Sgf) W = Flow, pounds per hour (lb./hr.)
Typical Gases Typical Liquid P1 = Inlet pressure, psia (14.7 + psig)
P2 = Outlet pressure, psia (14.7 + psig)
SG@RT SGF@RT
Gas Relative Liquid Relative Sgf = Liquid specific gravity (water = 1.0)
to Air to Water
Sg = Gas specific gravity (air = 1.0)
Acetylene 0.897 Acetone 0.792 Tf = Flowing temp., R absolute (460 + F)
Air 1.000 Alcohol 0.792
Benzine 0.902 Ts = Superheat in F
Ammonia 0.587
Argon 1.377 Gasoline 0.751 Cv = Valve coefficient of flow, full open
Butane 2.070 Gasoline, nat. 0.680
* Effect of flowing temperatures on gas flow are minimal for temperatures between 30F
Carbon Dioxide 1.516 Kerosene 0.815
(-1.1C) and 150F (66C). Correction should be included if temperatures are higher or
Ethylene 0.967 Pentane 0.624 lower.
Helium 0.138 Water 1.000
Hydrogen 0.0695 Where outlet pressure P2 is equal to or less than 1/2 inlet pressure P1, the term:
Methane 0.553
(P1 - P2) (P1 + P2) becomes 0.87 P1
Nitrogen 0.966
Oxygen 1.103 Note: Maximum Cv values in this catalog have been determined in accordance with the Fluid Controls
Institute report FCI58-2. Recommended Voluntary Standards for Measurement Procedure for
Propane 1.562 Determining Control Valve Flow Capacity, including procedure, design of the test stand and evaluation
Sulphur Dioxide 2.208 of the data.
All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold. 11
Technical Information - Liquid Flow Curves
Tubing
Theoretical Pressure Drop & Fluid Velocity vs. Flow, total pressure loss. See note below to correct for system
Parker Autoclave Engineers Medium and High Pressure Tub- pressures above atmospheric. To determine the average fluid
ing. (Based on water @ RT) velocity, repeat the above procedure, but use the dashed line.
The pressure drop is for straight lengths of tube only.
Legend Pressure drop P = psi/ft. (bar/m)
Velocity V = Ft./s (m/s) 50
(11.30) .188
.109 (4.76)
[15.24]
(2.77)
50 .062 .109
.203
(11.30) (5.16)
.062 (1.51) (2.77)
[15.24] (1.51) .083 .125 Pressure Drop 40
(2.11) (3.17) (9.04)
Unit Length [12.19]
Pressure Drop 40 P = psi/ft. (bar/m)
(9.04)
Unit Length [12.19] Velocity 30
.125
P = psi/ft. (bar/m) (3.17) V = ft./s [m/s] (6.78)
Velocity [9.14] .188
30 (4.76) .203
V = ft./s [m/s] (6.78) (5.16)
[9.14] 20
.083 (4.52)
(2.11) [6.09]
20
(4.52)
[6.09] 10
(2.26)
[3.04]
10
(2.26) Use this set of curves
[3.04] for .109, .188 and .203
Use this set of curves inch (2.77, 4.76, & 1 2 3 4 5
for .062, .083 and .125 5.16 mm) inside (3.5) (8.8) (13.2) (17.6) (22.0)
inch (1.25, 2.11 & 3.17 .5 1.0 1.5 2.0 diameter tubing.
mm) inside diameter (2.2) (3.5) (6.6) (8.8) Flow Q GPM (LPM)
tubing.
Flow Q GPM (LPM)
50
(11.30)
[15.24] .516
50 .562 .688
(13.11) (14.27)
(11.30) .359 (17.48)
[15.24] .250 (9.12)
.438 Pressure Drop 40
(6.35) (9.04)
(11.13) Unit Length [12.19]
Pressure Drop 40 P = psi/ft. (bar/m)
(9.04) .312
Unit Length [12.19] (7.92) Velocity 30
P = psi/ft. (bar/m) V = ft./s [m/s] (6.78)
[9.14]
Velocity 30
V = ft./s [m/s] (6.78)
[9.14] 20
(4.52)
[6.09]
20
(4.52) .250 .516
(6.35) (13.11)
[6.09]
.312 10
(2.26) .562
(7.92) (14.27)
[3.04]
10 .688
(2.26) .359 Use this set of curves (17.48)
[3.04] (9.12) .438 for .516, .562 and .688
Use this set of curves (11.13) inch (13.11, 14.27, & 10 20 30 40 50 60
for .250, .312, .359 and 17.48 mm) inside (44.0) (88.1) (132.1) (176.2) (220.2) (264.3)
.438 inch (6.35, 7.92, 5 10 15 20 diameter tubing.
9.12 & 11.13 mm) (22.0) (44.01) (66.1) (88.1) Flow Q GPM (LPM)
inside diameter tubing.
Flow Q GPM (LPM)
Example: What would be the expected pressure drop and average fluid
velocity at 1 gallon (4.4 liter) per minute of water through 100 feet (30.48
60
meters) of 3/8 outside diameter x .125 inside diameter tubing at 30,000
System pressure KSI (MPa)
(413.8)
50 psi (2068 bar) will be used. This curve lists .125 inch (.317mm) inside
(344.9) diameter data.
40
(275.9) From the x-axis (Flow Q GPM (LPM) at 1 GPM (3.5 LPM) a vertical line
30 is drawn until it intersects the solid line labeled .125 (3.17mm).
(206.9)
20 A horizontal line is then traced to the y-axis )Pressure Drop/Unit Length)
(138.0) and is read 12 psi/ft. (2.71 bar/m).
10
(69.0) Since the system pressure is 30,000 psi (2068 bar), a correction must
1.00 1.02 1.04 1.06 1.08 1.10 be made to this value 12 psi/ft. (2.71 bar/m). The small graph in the
lower left corner is used to determine this correction factor. A horizontal
Compressibility Correction Factor 'C'
line on this graph is drawn from the y-axis System Pressure KSI (MPa)
Note: Multiply pressure drop (P/ft) from graph above by factor C to correct for sys- until it intersects the curve. It is then traced vertically to the x-axis
tem pressure above atmospheric. Higher system pressure increases the fluid density (Compressibility Correction Factor C) and is read as 1.054.
resulting in higher system pressure loss.
To determine the total pressure drop, multiply the total tube length by the
Instructions: To determine the expected pressure drop, per expected pressure drop per foot and by the correction factor C (100)
foot of tube length, select the appropriate curves based on (12) (1.054) = 1,265 psi [(30.48m)(2.71 bar/m) (1.054)=87.10 bar].
tube Inside Diameter. Follow the graph vertically at the design The average fluid velocity is determined in a similar way except that on
flow rate (X-axis) until it intersects the solid line, then move the original graph, the dashed line is used instead of the solid line. the
average fluid velocity at 1 GPM (4.4 LPM) would be 25 ft/s (7.62 m/s).
horizontally to read the expected pressure drop per foot No correction needs to be made for elevated system pressures.
(Y-axis). Multiply this by the total tube length to obtain the
12 All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold.
Technical Information - Conversion Tables
Temperature Equivalents
Degrees Fahrenheit = F
Fahrenheit F Celcius C RankineR KelvinK
Degrees Celcius = 5/9 (F - 32)
0 -18 460 255 Degrees Kelvin = C + 273.15
32 0 492 273
Degrees Rankine = F + 459.67
-460 -273 0 0
Linear Equivalents
foot inch meter centimeter millimeter micron angstrom
1 12 0.3048 30.48 304.800 3.048x105 3.048x109
0.08333 1 0.0254 2.54 25.4 2.54x104 2.54x108
3.28083 39.37 1 100 1000 1x106 1x1010
0.03281 0.3937 0.01 1 10 1x104 1x108
3.281x10-3 0.03937 0.001 0.1 1 1000 1x107
3.281x10-6 3.937x10-5 1x10-6 1x10-4 1x10-3 1 1x104
3.281x10-10 3.937x10-9 1x10-10 1x10-8 1x10-7 1x10-4 1
Pressure Equivalents
PSIG = lb./in.2 Gage
Pa MPa atm bar kg/cm2 psi inches Hg Microns Hg
PSIG = lb./in.2 absolute
1 1x10-6 9.8692x10-6 1x10-5 1.0197x10-5 1.4504x10-4 2.9530x10-4 7.50059 PSIA = PSIG plus atmospheric pressure
1x10-6 1 9.8692 10 10.1971 145.04 295.30 7.5006x106
1Torr = 133.322Pa
101325 0.101325 1 1.01325 1.0332 14.696 29.921 760x103
Volume Equivalents
US. gallon = 0.833 British Imperial gallon
meter3 foot3 gallon* liter quart inch3 cc
British Imperial gallon = 1.201 US. gallon
1 35.31 264.2 1000 1056.8 61023 1x106
US. gallon water = 8.345 pounds
28.317x10-3 1 7.4822 28.317 29.92 1728 28.317x103
3.785x10-3 0.1337 1 3.785 4 231 3785 British Imperial gallon water= 10.022
pounds
1x10-3 0.03531 0.2642 1 1.057 61.023 1000
9.463x10-4 0.03342 0.25 0.9463 1 57.75 946.25 US. fluid ounce = 29.573 centimeters3
1.638x10-5 5.787x10-4 43.29x10-4 0.01639 0.01732 1 16.387 British Imperial fluid ounce = 28.413
1x10-6 35.31x10-6 2.642x10-4 1x10-3 10.568x10-4 0.06102 1 centimeters3
*U.S. Gallons
Density Equivalents
pound/inch3 pound/ft3 kg/meter* pound/gallon3 gram/cm3
1 1728 231 27.68x103 27.6797
5.787x10-4 1 0.1337 16.018 0.01602
4.33x10-3 7.48 1 119.8257 0.11983
3.613x10-5 0.06243 8.3445x10-3 1 .001
0.03613 62.43 8.3445 1000 1
*U.S. Gallons
Fluid Flow Equivalents
*gal/hr *gal/min cu ft/hr cu ft/min liters/hr liters/min cc/min
1 0.01667 0.1337 2.228x10 -3
3.7848 0.06308 63.08
60 1 8.022 0.1337 227.1 3.7848 3784.8
7.48 0.1247 1 0.01667 28.32 0.472 472
448.8 7.48 60 1 1698.6 28.32 28.32x103
0.26418 4.403x10-3 0.03531 5.886x10-4 1 0.01667 16.67
15.8502 264.18x10-3 2.11887 0.03531 60 1 1000
.01585 264.2x10-6 2.1187x10-3 35.3145x10-6 .06 0.001 1
*U.S. Gallons
All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold. 13
Technical Information - Conversion Tables
Area Equivalents
ft2 in2 m2 cm2 mm2
1 144 0.09291 929.034 9.29x104
6.944x10-3 1 6.451x10-4 6.4516 645.1625
10.7639 1550 1 1x10-4 1x106
1.0764x10-3 0.155 1x10-4 1 100
1.076x10-5 1.55x10-3 1x10-6 .01 1
Weight Equivalents
pound ounce kilogram gram grain
1 16 .45351 453.592 7000
0.0625 1 .02836 28.345 437.5
2.205 35.27 1 1000 15.435x103
2.205x10-3 0.03527 0.001 1 15.435
1.428x10-4 0.002285 64.8x10-6 0.0648 1
Power Equivalents
US. horsepower = 1.014 metric horse-
kilowatt horsepower* ft lbs/sec ft lbs/min ft lbs/hr Btu/sec Btu/min Btu/hr power
1 1.341 738 44.280 2.653x106 0.948 56.9 3413 Metric. horsepower = 0.986 US. horse-
.7457 1 550 33x103 1.99x106 0.707 42.41 25.44 power
13.55x10-4 18.18x10-4 1 60 3600 12.84x10-4 0.0771 4.62
14 All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold.
Technical Information - Pressure vs. Bend Radius
Tubing
Allowable Pressure vs. Bend (Mandrel) Radius
Parker Autoclave Engineers Medium & High Pressure tubing
(316 & 304 SS)
60,000 60,000 and 100,000 psi (4137 & 6895 bar)
(41.4) High Pressure Tubing Mandrel radius
(Rm)
Size Rm (min.)
59,000 60,000 psi (4137 bar) Inches inches (mm)
(40.7) high pressure tubing 1 1/4 x .083 1.25 (31.8)
1 2 3/8 x .125 1.75 (44.5)
58,000 3 9/16 x .188 2.625 (66.7)
(40.0) 2 3
Size Rm (min.)
(29.0) Inches inches (mm)
41,000 43,000 psi (2965 bar) 1 x .438 4.625 (117.5)
(28.3) high pressure tubing
40,000 40,000 psi (2758 bar)
(27.6) High Pressure Tubing
Size Rm (min.)
39,000 Inches inches (mm)
(26.9) 1 9/16 x .250 2.625 (66.7)
1
40,000 psi (2756 bar) 2 9/16 x .312
2 high pressure tubing
20,000 psi (1379 bar)
Medium Pressure Tubing
20,000
(13.8) Size Rm (min.)
1 Inches inches (mm)
19,000 1 1/4 x .109 1.25 (31.8)
2 20,000 psi (1379 bar) 2 3/8 x .203 1.75 (44.5)
(13.0) 3 4 5 medium pressure tubing 3 9/16 x .312 2.625 (66.7)
4 3/4 x .438 3.5 (89.9)
5 1 x .562 4.625 (117.5)
15,000
15,000 psi (1034 bar)
(1034) 1 Medium Pressure Tubing
15,000 psi (1034 bar) Size Rm (min.)
14,000 2 3 medium pressure tubing Inches inches (mm)
(9.6)
1 9/16 x .359 2.625 (66.7)
0 1 2 3 4 5 6 9 10 11 12 13 14
7 8 2 3/4 x .516 3.5 (89.9)
Mandrel Radius (inches) 3 1 x .688 4.625 (117.5)
4 1 1/2 x .938 4.50 (114.3) (Curved not shown)
Parker Autoclave Engineers Ultra High Pressure tubing (316SS)
MAWP psi x 1000 (bar x 1000)@ RT
All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold. 15
WARNING
FAILURE, IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS AND/OR SYSTEMS DESCRIBED HEREIN OR RELATED ITEMS CAN CAUSE DEATH, PERSONAL INJURY AND PROPERTY DAMAGE.
This document and other information from Parker Hannifin Corporation, its subsidiaries and authorized distributors provide product and/or system options for further investigation by users having technical
expertise. It is important that you analyze all aspects of your application and review the information concerning the product or system in the current product catalog. Due to the variety of operating conditions
and applications for these products or systems, the user, through its own analysis and testing, is solely responsible for making the final selection of the products and systems and assuring that all performance,
safety and warning requirements of the application are met. The products described herein, including without limitation, product features, specifications, designs, availability and pricing, are subject to change by
Parker Hannifin Corporation and its subsidiaries at any time without notice.
Offer of Sale
The items described in this document are available for sale by Parker Hannifin Corporation, its subsidiaries or its authorized distributors. Any sale contract entered by Parker will be governed by the provisions
stated in Parker's standard terms and conditions of sale (copy available upon request).
2013 Parker Hannifin Corporation | Autoclave Engineers is a registered trademark of the Parker Hannifin Corporation 02-0142SE January2013
Instrumentation Products Division Parker Hannifin Manufacturing Ltd. Caution! Parker Autoclave Engineers Valves, Fittings and Tools are
Autoclave Engineers Operation Instrumentation Products Division, Europe not designed to work with common commercial instrument tubing
and will only work with tubing built to Parker Autoclave Engineers
8325 Hessinger Drive Industrial Estate Whitemill
AES Specifications. Failure to do so will void warranty.
Erie, Pennsylvania 16509-4679 USA Wexford, Republic of Ireland
PH: 814-860-5700 FAX: 814-860-5811 PH: 353 53 914 1566
www.autoclave.com FAX: 353 53 914 1582 ISO-9001 Certified
VFT
Lubrication Guide
General Information
For reliable operation and long life of hand valves, air valves, relief valves, check valves and safety heads,
Autoclave Engineers strongly recommends proper lubrication of all components that are subject to friction dur-
ing assembly and /or operation. This is especially important where metal to metal contact occurs such as on
connection gland threads, packing gland threads and stem threads. Without proper lubrication, the high loads
imposed on these threads may cause the parts to weld (or gall) together from the high metal to metal contact
forces and friction heat. Lubrication is also essential for the effective sealing and long life of o-rings, especially
those that are used in dynamic sealing applications. The performance of metal to metal seals will be improved
with lubrication but, they do not absolutely require it.
Lubricant selection is strongly dependent on the application of the given component. Process fluids, fluid tem-
perature, ambient environment temperature, materials and other factors are important in selecting a lubricant.
This manual gives some basic guidelines in the proper selection and application of lubricants. The end user
must ultimately determine the suitability of a lubricant based on process requirements.
Note: Autoclave Engineers assumes no liability in selecting lubricant for customer applications.
Note: This information is provided for reference only. The manufacture of the lubricant should be contacted for
specific information based on your application. Refer to the material safety data sheets for information on safe
usage and storage methods for these lubricants.
Metal to
Metal to Metal Metal Lubricant
Lubricant
Metal to Metal
Seal Surface Lubricant
Figure 5 Figure 6
Relief Valve Safety Head
Lubrication Sites Lubrication Sites
All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold.
! WARNING !
FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS AND/OR SYSTEMS
DESCRIBED HEREIN OR RELATED ITEMS CAN CAUSE DEATH, PERSONAL INJURY AND/OR PROPERTY DAMAGE.
This document and other information from Snap-tite, Inc., its subsidiaries and authorized distributors, provides product and/or system options for further investigation by users having technical expertise. It is important that you analyze all
aspects of your application and review the information concerning the product or system in the current product catalog. Due to the variety of operation conditions and applications for these products or systems, the user, through its own
analysis and testing, is solely responsible for making the final selection of the products and systems and assuring that all performance, safety and warning requirements of the application are met. The products described herein, including
without limitation, product features, specifications, designs, availability and pricing, are subject to change by Snap-tite, Inc. and its subsidiaries at any time without notice.
Industrial Estate
Whitemill-Wexford 8325 Hessinger Drive
ISO-9001 Certified Republic of Ireland
PH: 353-53-41566 FAX: 353-53-41582
Erie, Pennsylvania 16509-4679 USA
PH: 814-838-5700 FAX: 814-838-5811
e-mail: ste_sales@snap-tite.com e-mail: ae_sales@snap-tite.com
02-0027BE-0304 www.snap-tite.com www.autoclaveengineers.com
This page left blank
2
QSS-Quick Set System
Index
QSS Introduction................................... 4-5
QS Valves........................................... 7-9
1/4", 3/8", 9/16" and 3/4", Pressures to 15,000 psi (1034 bar)
QS Adapters..................................... 37-43
Male to Female
QSS - Index
3
QSS-Quick Set System
Safe, Reliable, Cost Effective
Parker Autoclave Engineers, the recog-
nized world leading designer and manu-
facturer of high pressure equipment up to
150,000 psi (10342 bar), has engineered
an advanced single ferrule fitting system
called the QSS-Quick Set System. This
1/4 through 3/4 O.D. heavy-walled, high
flowing tubing system operates in all sizes
up to 15,000 psi (1034 bar).
4
QSS-Quick Set System
As Simple as 1, 2, 3
Assembly of Parker Autoclave Engineers QS Series fittings couldnt be
more simple.
1) Slide on our inverted gland nut
2) Slide on our single ferrule 3
3) Insert into fitting body and tighten using the positioning mark
on the outside of the gland nut for reference
For our larger sizes our hydraulic set tool is required to ensure a
complete and superior tube bite.
1
Features
Proprietary single sleeve design provides superior tubing bite
reducing failure from vibration
Fewer parts to lose, reduced assembly errors
2
Long tube-support area provides resistance to vibration and
tube stress
Components manufactured from high strength Stainless Steel
Molybdenum Disulfide coated gland nuts help prevent galling
and allow for multiple remakes.
Pressure Ratings
Pressure ratings for a fluid system are determined by the
fitting or system component (including tubing) with the
lowest pressure rating. Maximum pressure ratings are marked
on all QS Series valves and fittings.
System Components Flow/Pressure
Working
Pressure (bar)** QSS -Quick Set System
Connection Orifice Flow Temperature
Diameter Area* 0 to 650F
in (mm) in2 (mm2) (-17.8 to 343C)
1/4 0.109 (2.77) 0.009 (5.81) 15,000 (1034)
3/8 0.203 (5.16) 0.032 (20.65) 15,000 (1034)
9/16 0.359 (9.12) 0.101 (65.16) 15,000 (1034)
3/4 0.516 (13.11) 0.209 (134.84) 15,000 (1034)
* Flow area shown is minimum system flow area including tubing.
** Maximum Working pressure is based on lowest rating of any system component.
5
This page left blank
6
Needle Valves
QS Series
Medium Pressure
compression sleeve design, providing fast easy make-up and reliable bubble-tight performance
in liquid or gas service.
7
Needle Valves - QS Series
Pressures to 15,000 psi (1034 bar)
Pressure/
Tube Temperature
Outside Rating
Diameter Orifice psi (bar)
Size Connection Size Rated @ Room
Inches Type Inches (mm) Cv* Temperature**
Notes:
* CV values shown are for 2-way straight valve pattern. For 2-way
angle patterns, increase CV value 50%. (Based on water)
5
ANTI-EXTRUSION
BACK-UP RINGS
4
ADJUSTABLE PACKING
BELOW THREADS
COLD WORKED
TYPE 316 SS
3
BODY IN FIVE
PATTERNS
2
MEDIUM Vee Stem
PRESSURE
COMPRESSION
1
SLEEVE
CHOICE OF VEE CONNECTIONS
METAL-TO-METAL
OR REGULATING
STEM TIP
SEATING
0
10 20 30 40 50 60 70 80 90 100
To ensure proper fit use Parker Autoclave Engineers tubing % of rated Cv
Ordering Procedure
For complete information on available stem types, optional connections and additional valve options, see Needle Valve Options section or contact
your Sales Representative. QS Series valves are furnished complete with connection components, unless otherwise specified.
15QS 4 07 1 Options
Valve Outside Diameter Stem/Seat Body Options
Series Tube Size Type Pattern
For extreme
15QS 4-1/4 07 - non-rotating 1 - two-way straight
temperature and other
6-3/8 Vee stem (on-off service) 2 - two-way angle options, see
9-9/16 08 - non-rotating 3 - three-way, two on pressure Valve Options.
12-3/4 regulating stem (tapered tip
4 - three-way, one on pressure
for regulating and shutoff)
5 - three-way, two stem
87 - Vee stem with replaceable seat
manifold valve
88 - Regulating stem with replaceable seat
8
Valve Options Valve Maintenance
Extreme Temperatures Repair Kits: add R to the front of valve catalog
Standard Parker Autoclave Engineers valves with PTFE packing may number for proper repair kit.
be operated to 450F (232C). High temperature packing and/or (Example: R15QS4071)
extended stuffing box are available for service from 0F (-17.8C) to Valve Bodies: Valve bodies are available. Order using the eight (8)
650F (343C) by adding the following suffixes to catalog order digit part number found on the valve drawing or
number. contact your Sales Representative for information.
TG standard valve with PTFE glass packing to 600F (316C).
GY standard valve with graphite braided yarn packing to 650F (343C). Consult your Parker Autoclave Engineers representative for pricing on repair
kits and valve
Parker Autoclave Engineers does not recommend compression sleeve connections bodies.
below 0F (-17.8C) or above 650F (343C). For additional valve options, contact
your Sales Representative.
Outside
Dimensions - inches (mm) Block
Catalog Stem Diameter Orifice Thick- Valve
Number Type Tube Diameter A B C D D1 E F G G1 H* M N ness Pattern
2-Way Straight
15QS4071 VEE 1/4 0.125 2.00 1.00 0.38 1.62 1.19 2.00 3.00 0.75 0.22 4.69 0.62 0.38 0.75
15QS4081 REG (6.35) (3.18) (50.80) (25.40) (9.53) (41.15) (30.23) (50.80) (76.20) (19.05) (5.59) (119.13) (15.75) (9.65) (19.05)
15QS6071 VEE 3/8 0.219 2.00 1.00 0.47 1.62 1.19 2.00 3.00 0.75 0.22 4.63 0.62 0.38 0.81
15QS6081 REG (9.53) (5.56) (50.80) (25.40) (11.94) (41.15) (30.23) (50.80) (76.20) (19.05) (5.59) (117.60) (15.75) (9.65) (20.57) See
15QS9071 VEE 9/16 0.359 3.00 1.50 0.53 2.38 1.75 3.00 4.00 1.00 0.34 6.05 0.69 0.50 1.25 Figure 1
15QS9081 REG (14.29) (9.12) (76.20) (38.10) (13.46) (60.45) (44.45) (76.20) (101.60) (25.40) (8.64) (153.67) (17.53) (12.70) (31.75)
15QS12071 VEE 3/4 0.516 4.12 2.06 0.62 3.00 2.25 3.88 10.25 1.12 0.44 7.13 0.88 0.63 1.50
15QS12081 REG (19.05) (13.11) (104.65) (52.32) (15.75) (76.20) (57.15) (98.43) (260.35) (28.45) (11.18) (180.98) (22.35) (16.00) (38.10)
2-Way Angle
15QS4072 VEE 1/4 0.125 2.00 1.00 0.38 1.19 2.44 3.00 0.75 0.22 4.81 0.62 0.38 0.75
15QS4082 REG (6.35) (3.18) (50.80) (25.40) (9.53) (30.23) (61.98) (76.20) (19.05) (5.59) (122.17) (15.75) (9.65) (19.05)
15QS6072 VEE 3/8 0.219 2.00 1.00 0.47 1.20 2.56 3.00 0.75 0.22 4.93 0.62 0.38 0.81
15QS6082 REG (9.53) (5.56) (50.80) (25.40) (11.94) (30.48) (65.02) (76.20) (19.05) (5.59) (125.22) (15.75) (9.65) (20.62) See
15QS9072 VEE 9/16 0.359 3.00 1.50 0.53 1.69 3.50 4.00 1.00 0.36 6.55 0.69 0.50 1.25 Figure 2
15QS9082 REG (14.29) (9.12) (76.20) (38.10) (13.46) (42.88) (88.90) (101.60) (25.40) (9.14) (166.37) (17.53) (12.70) (31.75)
15QS12072 VEE 3/4 0.516 4.12 2.06 0.62 2.19 4.63 10.25 1.12 0.44 7.88 0.88 0.63 1.50
15QS12082 REG (19.05) (13.11) (104.65) (52.32) (15.75) (55.58) (117.48) (260.35) (28.45) (11.18) (200.15) (22.35) (16.00) (38.10)
G - Packing gland mounting hole drill size * H Dimension is with stem in closed position. For prompt service, Parker Autoclave Engineers stocks
G - Bracket mounting hole size **1/8" straight and 3-Way/2 on pressure valves have offset select products. Consult factory.
1
Panel mounting drill size: 0.22 all valves. tube connections All dimensions for reference only and subject to change.
Figure 1 Figure 2
F F
G1 M M M M G
H N G G1
H
N
D1 D
D E
E
C C
B
A B
A
2-Way Straight 2-Way Angle
9
This page left blank
10
Ball Valves
2-Way QS Series
Pressures to 15,000 psi (1034 bar)
11
11
Ball Valves - 1/4 2-Way QS Series
Pressures to 15,000 psi (1034 bar) .250 (6.35mm) Orifice
STOPPING DEVICE
15,000 (1034)
QS CONNECTION
PRESSURE PSIG
PRESSURE BAR
PACKING GLAND
THRUST WASHER
LOCKING PIECE
5,000 (345)
0
PEEK BEARING VITON O-RING 100 200 300 400 500
SEAT RETAINER
TEMPERATURE F
NOTE: Ball valves are not recommended for critical gas applications such as Hydrogen, Helium or other small molecular gases.
Ordering Procedure
For complete information on available end connections see complete catalog.
2B 4 S 15 Q4 XXX
Valve Ball Material Pressure End Connection Options
Series Orifice (X 1000 psi)
2B: 2-way Diameter S -316SS Q4 - QS 250 HT - High Temperature
4-1/4 (See Chart on next (Ball Valve Actuators,
(6.35 mm) page) see next page)
12
End Connection Options
Seat Gland
Catalog End Connection MAWP @ Hex
Number Number Connection Room Temperature Inches(mm)
13
Ball Valves - 3/8 2-Way QS Series
Pressures to 15,000 psi (1034 bar) .359 (9.12mm) Orifice
TEMPERATURE C
(-18) (38) (93) (150) (204) (260)
20,000 (1379)
ONE PIECE BALL
AND STEM
STOPPING DEVICE
15,000 (1034)
PACKING GLAND QS562 CONNECTION
PRESSURE PSIG
PRESSURE BAR
THRUST WASHER
LOCKING PIECE
5,000 (345)
0
PEEK BEARING VITON O-RING 100 200 300 400 500
SEAT RETAINER TEMPERATURE F
NOTE: Ball valves are not recommended for critical gas applications such as Hydrogen, Helium or other small molecular gases.
Ordering Procedure
For complete information on available end connections see complete catalog.
2B 6 S 15 Q9 XXX
Valve Ball Material Pressure End Connection Options
Series Orifice (X 1000 psi)
2B: 2-way Diameter S - 316SS Q9 - QS562 HT - High Temperature
(See Chart on next (Ball Valve Acutators,
6-3/8
page) see next page.)
(9.52 mm)
14
End Connection Options
Seat Gland
Catalog End Connection MAWP @ Hex
Number Number Connection Room Temperature Inches(mm)
15
Ball Valves - 1/2 2-Way QS Series
Pressures to 15,000 psi (1034 bar) .500 (12.7mm) Orifice
TEMPERATURE C
(-18) (38) (93) (150) (204) (260)
ONE PIECE BALL STOPPING DEVICE 15,000 (1034)
AND STEM
PACKING GLAND
QS750 CONNECTION
THRUST WASHER
LOCKING PIECE
SPRING ENERGIZED SEAL CARBON FILLED
(690)
PRESSURE PSIG
10,000
PRESSURE BAR
PEEK SEATS
5,000 (345)
NOTE: Ball valves are not recommended for critical gas applications such as Hydrogen, Helium or other small molecular gases.
Ordering Procedure
For complete information on available end connections see complete catalog.
2B 8 S 15 MAQ12 XXX
Valve Ball Material Pressure End Connection Options
Series Orifice (X 1000 psi)
2B: 2-way Diameter S -316SS MAQ12 - Male QS750 HT - High Temperature
16
End Connection Options
Seat Gland
Catalog End Connection MAWP @ Square
Number Number Connection Room Temperature Inches(mm)
2B8S15MAQ12 MAQ12 Male QS750 15,000 psi (1034 bar) 1.19 (30.2)
MAWP: Maximum Allowable Working Pressure
17
Ball Valve Dimensions - inches (mm)
VALVE MODELS
E*
2B4S 2B6S 2B8S
4.33 4.97 5.97
E
A (109.99) (126.30) (151.64)
D
4.19 5.53 6.85
B (106.49) (140.41) (173.99)
G
E
3.90
(99.02)
5.52
(140.32)
*(260.35)
10.25
BLOCK THICKNESS
A
1.13 1.38 1.76 H
F (28.58) (34.92) (44.70)
J
1.50 2.00 3.00 TYPICAL
G (38.10) (50.80) (76.20) F L
C (Diameter)
VALVE MODELS
2B4S 2B6S 2B8S D (Typical Diameter)
See Note:
1.500 2.000 3.000
A (38.10) (50.80) (76.20)
Note: Body mounting 1/4 - 20 thread All dimensions are for reference only
and are subject to change without notice.
18
Ball Valves
3-Way QS Series
Pressures to 15,000 psi (1034 bar)
19
Ball Valves - 3/16" 3-Way QS Series
Pressures to 20,000 psi (1379 bar) .187 (4.77mm) Orifice
Valve Cv=.50
TEMPERATURE C
STOPPING DEVICE
ONE PIECE BALL
AND STEM
PACKING GLAND
15,000 (1034)
THRUST WASHER
LOCKING PIECE QS CONNECTIONS
PRESSURE PSIG
PRESSURE BAR
SPRING ENERGIZED SEAL BELLEVILLE WASHERS
BELLEVILLE BACKUP
LOCKNUT
SEAT GLAND 10,000 (690)
O-RING
5,000 (345)
O-RING
O-RING
CARBON FILLED PEEK SEATS
BEARING
SEAT RETAINER 0
100 200 300 400 500
BOTTOM GLAND
TEMPERATURE F
NOTE: Maximum side connection inlet pressure 15,000 psi (1034 bar).
NOTE: Ball valves are not recommended for critical gas applications such as Hydrogen, Helium or other small molecular gases.
Ordering Procedure
For complete information on available end connections see complete catalog
3B 3 S 15 Q4 XXX
Valve Ball Material Pressure End Connection Options
Series Orifice (X 1000 psi)
3B: 3-way Diameter S -316SS Q4 - QS250 HT - High Temperature
3BD: 3-way diverter (See Chart on (Ball Valve Actuators,
3-3/16
next page) see next page)
(4.77 mm)
20
End Connection Options
Catalog End Connection MAWP @ Hex
Number Number Connection Room Temperature Inches(mm)
3B3S15Q4 Q4 QS250 15,000 psi (1034 bar) 1 (25.40)
3BD3S15Q4
3B3S15Q6 Q6 QS375 15,000 psi (1034 bar) 1 (25.40)
3BD3S15Q6
*3-Way Diverter
*3-Way Diverter Valve
Valve 3-Way
3-WayBall
BallValve
Valve
90 Turn
Turn 180
180 Turn
Turn
90
*The Diverter Valve design permits inlet flow through the bottom port. Outlet flow may be diverted to either valve side port.
21
Ball Valves - 3/8" 3-Way QS Series
Pressures to 15,000 psi (1034 bar) .328 (8.33mm) Orifice
(690)
PRESSURE BAR
SPRING ENERGIZED SEAL BELLEVILLE WASHERS 10,000
BELLEVILLE BACKUP
LOCKNUT
SEAT GLAND
O-RING
5,000 (345)
O-RING 0
O-RING
CARBON FILLED PEEK SEATS
100 200 300 400 500
BEARING
SEAT RETAINER TEMPERATURE F
BOTTOM GLAND
Side connection pressure not recommended.
NOTE: Ball valves are not recommended for critical gas applications such as Hydrogen, Helium or other small molecular gases.
Ordering Procedure
For complete information on available end connections see complete catalog.
3B 6 S 15 Q9 XXX
Valve Ball Material Pressure End Connection Options
Series Orifice (X 1000 psi)
3B: 3-way Diameter S -316SS Q9 - QS562 HT - High Temperature
3BD: 3-way diverter
6-3/8 (See Chart on next (Ball Valve Actuators,
(9.52 mm) page) see next page)
22
End Connection Options
*3-Way
*3-Way Diverter
Diverter Valve
Valve 3-WayBall
3-Way BallValve
Valve
90
90 Turn
Turn 180Turn
180 Turn
*The Diverter Valve design permits inlet flow through the bottom port. Outlet flow may be diverted to either valve side port.
23
Ball Valves - 1/2" 3-Way QS Series
Pressures to 10,000 psi (690 bar) .500 (12.7mm) Orifice
SET SCREW
PACKING GLAND PRESSURE TEMPERATURE RATINGS
THRUST WASHER LOCKING PIECE
BELLEVILLE WASHERS
TEMPERATURE C
STEM SEAL
BELLEVILLE BACKUP
LOCKNUT (-18) (38) (93) (150) (204) (260)
SEAT GLAND
15,000 (1034)
(690)
PRESSURE BAR
PRESSURE PSIG
10,000
QS CONNECTION
O-RING
O-RING O-RING
0
100 200 300 400 500
TEMPERATURE F
NOTE: Ball valves are not recommended for critical gas applications such as Hydrogen, Helium or other small molecular gases.
Ordering Procedure
For complete information on available end connections see complete catalog.
3B 8 S 10 MAQ12 XXX
Valve Ball Material Pressure End Connection Options
Series Orifice (X 1000 psi)
3B: 3-way Diameter S -316SS MAQ12 - Male QS750 HT - High Temperature
3BD: 3-way diverter
8-1/2 (For material options (See Chart on (Ball Valve Actuators,
(12.7 mm) contact factory) next page) see next page)
24
End Connection Options
3B8S10MAQ12 MAQ12 Male QS750 10,000 psi (690 bar) 1.19 (30.2)
3BD8S10MAQ12
MAWP: Maximum Allowable Working Pressure
*3-Way Diverter
*3-Way Diverter Valve
Valve 3-Way
3-Way Ball
BallValve
Valve
90 Turn
90 Turn 180
180Turn
Turn
*The Diverter Valve design permits inlet flow through the bottom port. Outlet flow may be diverted to either valve side port.
25
Ball Valve Dimensions - inches (mm)
VALVE MODELS
3B3S/3BD3S 3B6S/3BD6S 3B8S/3BD8S
E
5.64 6.55 7.37 D
A (143.35) (166.37) (187.20)
D 0.28
(7.11)
0.28
(7.11
0.28
(7.11)
A
Note: Body mounting 1/4 - 20 thread All dimensions are for reference only
and are subject to change without notice.
26
Ball Valves
Actuators
Pneumatic Actuators
Electric Actuators
Electric Operators
Interface with control systems for automated operation
Ball Valves - Actuators
and monitoring
120 & 220 VAC, 50/60 Hz standard
24VDC
Explosion proof available
CE mark available
27
Ball Valves - Actuators
Pneumatic Operated Ball Valves
Add the suffix -AO, -AC or -AOC to the appropriate valve catalog number for a complete valve assembly
A B C D E F G H I J
2B4-AO/AC 6.69 2.56 2.50 1.25 1.00 0.50 0.28 1.14 2.50 1.58 80 psi
(169.92) (65.02) (63.50) (31.75) (25.40) (12.70) (7.11) (28.95) (63.50) (40.13) (5.51 bar)
2B6-AO/AC 9.84 3.94 3.00 1.50 1.50 0.75 0.34 1.87 3.00 2.24 80 psi
(249.93) (100.07) (76.20) (38.10) (25.40) (19.05) (8.63) (47.49) (76.20_) (56.89) (5.51 bar)
2B8-AO/AC 11.65 4.57 3.00 1.50 2.00 1.00 0.53 2.17 3.00 2.48 80 psi
*
3BD3-AO/AC
(259.91) (116.07) (76.20)
6.69 2.56 2.50
(38.10)
1.25
(50.80)
1.00
(25.40) (13.46)
0.50 0.28
(55.11)
1.14
(76.20)
2.50
(62.99)
1.58
(5.51 bar)
80 psi
(169.92) (65.02) (63.50) (31.75) (25.40) (12.70) (7.11) (28.95) (63.50) (40.13) (5.51 bar)
3BD6-AO/AC 9.84 3.94 3.00 1.50 1.50 0.75 0.34 1.87 3.00 2.24 80 psi
*
3BD8-AO/AC
(249.93) (100.07) (76.20)
11.65 4.57 3.00
(38.10)
1.50
(25.40)
2.00
(19.05)
1.00
(8.63)
0.53
(47.49) (76.20_) (56.89)
2.17 3.00 2.48
(5.51 bar)
80 psi
(259.91) (116.07) (76.20) (38.10) (50.80) (25.40) (13.46) (55.11) (76.20) (62.99) (5.51 bar)
2B4-AOC 6.69 2.56 2.50 1.25 1.00 0.50 0.28 1.14 2.50 1.58 80 psi
(169.92) (65.02) (63.50) (31.75) (25.40) (12.70) (7.11) (28.95) (63.50) (40.13) (5.51 bar)
2B6-AOC 7.95 3.07 3.00 1.50 1.50 0.75 0.34 1.40 3.00 1.77 80 psi
(201.93) (77.97) (76.20) (38.10) (38.10) (19.05) (8.63) (35.56) (76.20_) (44.95) (5.51 bar)
2B8-AOC 9.84 3.94 3.00 1.50 2.00 1.00 0.53 1.87 3.00 2.24 80 psi
(249.91) (100.07) (76.20) (38.10) (50.80) (25.40) (13.46) (47.49) (76.20) (56.89) (5.51 bar)
3BD3-AOC 6.69 2.56 2.50 1.25 1.00 0.50 0.28 1.14 2.50 1.58 80 psi
(169.92) (65.02) (63.50) (31.75) (25.40) (12.70) (7.11) (28.95) (63.50) (40.13) (5.51 bar)
3BD6-AOC 7.95 3.07 3.00 1.50 1.50 0.75 0.34 1.40 3.00 1.77 80 psi
(201.93) (77.97) (76.20) (38.10) (25.40) (19.05) (8.63) (35.56) (76.20_) (44.95) (5.51 bar)
3BD8-AOC 9.84 3.94 3.00 1.50 2.00 1.00 0.53 1.87 3.00 2.24 80 psi
(249.91) (100.07) (76.20) (38.10) (50.80) (25.40) (13.46) (47.49) (76.20) (56.89) (5.51 bar)
NOTE: Maximum allowable air pressure is 150 psi (10.34) Actuators operating temperature: -20F to 175F (-29C to 79C)
1/8 NPT female air connector (*= 1/4 NPT) High temperature actuator option available, consult factory
AO: Air to open/spring to close Stainless steel housing actuator models available, consult factory
AC: Air to close/spring to open Actuators available with limit switches and visual indicators.
AOC: Air to open/air to close (double acting) Corrosion resistant anodized aluminum housing.
Epoxy coated housing available.
Solenoids availabe, direct or nipple mount.
"A" "J" "H"
"A"/2
"B"
"G" DIAMETER
(2) Holes
"C" "F"
"D" "E"
"I"/2
28 "I"
Ball Valves - Actuators
Electric Operated Ball Valves
Add the suffix -EO1, -EO2 or -EO3 to the appropriate valve catalog number for a complete valve assembly
SERIES
A B C D E F
2B4-EO1 2.50 1.25 1.00 0.50 0.28 2.50 120 VAC
50/60 Hz
2B4-EO2 (63.50) (31.75) (25.40) (12.70) (7.11) (63.50) 240 VAC
2B6-EO1 3.00 1.50 1.50 0.75 0.34 3.00 120 VAC
50/60 Hz
2B6-EO2 (76.20) (38.10) (38.10) (19.05) (8.63) (76.20) 240 VAC
3BD3-EO1 2.50 1.25 1.00 0.50 0.28 2.50 120 VAC 50/60 Hz
3BD3-EO2 (63.50) (31.75) (25.40) (12.70) (7.11) (63.50) 240 VAC
3BD6-EO1 3.00 1.50 1.50 0.75 0.34 3.00 120 VAC
50/60 Hz
3BD6-EO2 (76.20) (38.10) (38.10) (19.05) (8.63) (76.20) 240 VAC
2B4-EO3 2.50 1.25 1.00 0.50 0.28 2.50 24 VDC
(63.50) (31.75) (25.40) (12.70) (7.11) (63.50)
2B6-EO3 3.00 1.50 1.50 0.75 0.34 3.00 24 VDC
(76.20) (38.10) (38.10) (19.05) (8.63) (76.20)
3BD3-EO3 2.50 1.25 1.00 0.50 0.28 2.50 24 VDC
(63.50) (31.75) (25.40) (12.70) (7.11) (63.50)
3BD6-EO3 3.00 1.50 1.50 0.75 0.34 3.00 24 VDC
(76.20) (38.10) (38.10) (19.05) (8.63) (76.20)
NOTE: EO1: Electric 120 VAC For other voltages consult factory
EO2: Electric 220 VAC Actuator operating temperature: -20F to 160F (-29C to 71C)
EO3: Electric 24 VDC Corrosive resistant Zytel housing
CSA approved for NEMA 4 & 4X Consult factory for epoxy option
5.88 4.50
(149.35) (114.30)
2.25
(57.15)
5.25
4.13 (133.35)
(104.90) 6.63
(168.40)
"F/2"
"F"
29
Ball Valves - Actuators
Electric Operated Ball Valves
Add the suffix -EO1, -EO2 or -EO3 to the appropriate valve catalog number for a complete valve assembly
11.04
(280.29)
8.87
(225.29)
0.53 (13.46)
3.00 (2) HOLES
(76.20)
1.50 1.00 (25.40)
(38.10) 2.00 (50.80)
1.50
3.00 (38.10)
(76.20)
30
Fittings and Tubing
QS Series
Medium Pressure
The Medium Pressure QS Series uses Parker Autoclave Engineers Quick Set compression sleeve
design. This single-ferrule compression sleeve connection delivers fast, easy make-up and
reliable bubble-tight performance in liquid or gas service.
Medium Pressure
31
31
Fittings and Tubing - QS Series
Pressures to 15,000 psi (1034 bar)
Parker Autoclave Engineers Medium Pressure QS
Fittings are designed for use with QS Series valves
and medium pressure tubing. These fittings feature
improved compression connections with larger
orifices for excellent flow capabilities. Autoclave
fittings and components are manufactured of high
strength stainless steel.
Connection Components
All Parker Autoclave Engineers valves and fittings are supplied complete with appropriate glands and sleeves. To order these com-
ponents separately, use order numbers listed. When using plug, sleeve is not required.
Add tube size ( ) Example: To ensure proper fit use Parker Autoclave Engineers tubing.
1/4 - 40 1/4 Gland - QSG 40 For mounting hole option add suffix PM to catalog number.
3/8 - 60 Consult factory for mounting hole dimensions.
9/16 - 90
3/4 - 120
Elbow
QSL4400 QS250 1/4 15,000 0.16 1.38 2.00 0.52 0.63 1.00 1.00 0.75
(6.35) (1034,20) (3.99) (34.93) (50.80) (13.23) (15.88) (25.40) (25.40) (19.05)
QSL6600 QS375 3/8 15,000 0.25 1.50 2.00 0.55 0.75 1.00 1.00 0.81
(9.53) (1034,20) (6.35) (38.10) (50.80) (14.00) (19.05) (25.40) (25.40) (20.62) See
QSL9900 QS562 9/16 15,000 0.36 2.19 3.00 0.82 1.19 1.50 1.50 1.25 Figure 1
(14.29) (1034,20) (9.12) (55.58) (76.20) (20.83) (30.18) (38.10) (38.10) (31.75)
QSL12 QS750 3/4 15,000 0.52 2.94 4.13 1.04 1.50 2.06 2.06 1.50
(19.05) (1034,20) (13.11) (74.63) (104.78) (26.37) (38.10) (52.40) (52.40) (38.10)
*Maximum pressure rating is based on the lowest rating For mounting hole option add suffix PM to catalog number.
of any component. Consult factory for mounting hole dimensions.
Actual working pressure may be determined by tubing Figure 1
pressure rating, if lower.
All dimensions for reference only and subject to change. D HEX
For prompt service, Parker Autoclave Engineers stocks F
select products. Consult your local representative.
C
E
A
B
Elbow
32
Outside Pressure Dimensions - inches (mm)
Catalog Connection Minimum Block Fitting
Diameter Rating Opening A B C D E F G Thickness
Number Type Pattern
Tube psi (bar)* Typical Thickness
Tee
QST4440 QS250 1/4 15,000 0.16 1.38 2.00 0.52 0.63 1.00 1.00 0.75
(6.35) (1034,20) (3.99) (34.93) (50.80) (13.23) (15.88) (25.40) (25.40) (19.05)
QST6660 QS375 3/8 15,000 0.25 1.50 2.00 0.55 0.75 1.00 1.00 0.81
(9.53) (1034,20) (6.35) (38.10) (50.80) (14.00) (19.05) (25.40) (25.40) (20.62) See
QST9990 QS562 9/16 15,000 0.36 2.19 3.00 0.82 1.19 1.50 1.50 1.25 Figure 2
(14.29) (1034,20) (9.12) (55.58) (76.20) (20.83) (30.18) (38.10) (38.10) (31.75)
QST12 QS750 3/4 15,000 0.52 2.94 4.13 1.04 1.50 2.06 2.06 1.50
(19.05) (1034,20) (13.11) (74.63) (104.78) (26.37) (38.10) (52.40) (52.40) (38.10)
Cross
QSX4444 QS250 1/4 15,000 0.16 2.00 2.00 0.52 0.63 1.00 1.00 0.75
(6.35) (1034,20) (3.99) (50.80) (50.80) (13.23) (15.88) (25.40) (25.40) (19.05)
QSX6666 QS375 3/8 15,000 0.25 2.00 2.00 0.55 0.75 1.00 1.00 0.81
(9.53) (1034,20) (6.35) (50.80) (50.80) (14.00) (19.05) (25.40) (25.40) (20.62) See
QSX9999 QS562 9/16 15,000 0.36 3.00 3.00 0.82 1.19 1.50 1.50 1.25 Figure 3
(14.29) (1034,20) (9.12) (76.20) (76.20) (20.83) (30.18) (38.10) (38.10) (31.75)
QSX12 QS750 3/4 15,000 0.52 4.13 4.13 1.04 1.50 2.06 2.06 1.50
(19.05) (1034,20) (13.11) (104.78) (104.78) (26.37) (38.10) (52.40) (52.40) (38.10)
For mounting hole option add suffix PM to catalog number. Consult factory for mounting hole dimensions.
Figure 2 Figure 3
F
D HEX
F C
C E
D
HEX A
E
A
B B
Tee Cross
Straight Coupling
15F44QQ QS250 1/4 15,000 0.16 0.75 1.63 0.52 0.63 Straight
(6.35) (1034,20) (3.99) (19.05) (41.28) (13.23) (15.88)
15F66QQ QS375 3/8 15,000 0.25 0.81 1.75 0.55 0.75 Straight
(9.53) (1034,20) (6.35) (20.65) (44.45) (14.00) (19.05) See
15F99QQ QS562 9/16 15,000 0.36 1.38 2.75 0.82 1.19 Straight Figure 4
(14.29) (1034,20) (9.12) (34.93) (69.85) (20.83) (30.18)
15F12Q QS750 3/4 15,000 0.52 1.50 3.75 1.04 1.50 Straight
(19.05) (1034,20) (13.11) (38.10) (95.25) (26.37) (38.10)
Bulkhead Coupling
15BF44QQ QS250 1/4 15,000 0.16 0.88 2.00 0.52 0.63 0.63 1.00 0.38
(6.35) (1034,20) (3.99) (22.23) (50.80) (13.23) (15.88) (15.88) (25.40) (9.53)
15BF66QQ QS375 3/8 15,000 0.25 1.06 2.38 0.55 0.75 0.79 1.38 0.38
(9.53) (1034,20) (6.35) (27.00) (60.33) (14.00) (19.05) (19.94) (34.93) (9.53) See
15BF99QQ QS562 9/16 15,000 0.36 1.63 2.63 0.82 1.19 0.91 1.88 0.38 Figure 5
(14.29) (1034,20) (9.12) (41.40) (66.68) (20.83) (30.18) (22.99) (47.75) (9.53)
15BF12Q QS750 3/4 15,000 0.52 1.88 3.50 1.04 1.50 1.50 2.13 0.38
(19.05) (1034,20) (13.11) (47.63) (88.90) (26.37) (38.10) (38.10) (53.98) (9.53)
*Maximum pressure rating is based on the lowest rating of any component. All dimensions for reference only and subject to change. Union Couplings are designed with a removable seat insert
Actual working pressure may be determined by tubing pressure rating, For prompt service, Autoclave stocks select products. allowing disassembly and tubing removal without the necessity of
if lower. Consult your local representative. loosening other items in a line.
Figure 4 Figure 5
G MAX
A HEX
D D
HEX F
HEX A
B C
E
B C
Straight Coupling Bulkhead Coupling
33
Medium Pressure Tubing
Pressures to 15,000 psi (1034 bar)
Catalog Tube Fits Tube Size Inches (mm) Flow Working Pressure psi (bar)*
Number Material Connection Outside Inside Wall Area -325 to 100F 200F 400F 600F
Type Diameter Diameter Thickness in.2 (mm2) -198 to - 37.8C 93C 204C 316C
34
Nipples - QS Series
Pressures to 15,000 psi (1034 bar)
Materials
Catalog numbers in table refer to Type 316 Stainless Steel.
Catalog Numbers Working
Fits Tube Size Pressure
Nipple Length Inches (mm)
Connection Inches (mm) at 100
4.00 6.00 8.00 10.00 12.00 Type psi (bar)
(101.60) (152.40) (203.20) (254.60) (304.80) OD ID
Elbow Tube
Size Fits Connection Dimension H Mean Radius R Inside Radius Ri
Model Type Inches (mm)
Inches (mm) Inches (mm) Inches (mm)
QTE44-90 1/4 (6.35) QS250 3.25 (82.55) 0.563 (14.30) 0.438 (11.13)
QTE66-90 3/8 (9.53) QS375 3.50 (88.90) 0.938 (23.83) 0.75 (19.05)
QTE99-90 9/16 (14.29) QS562 7.50 (19.05) 2.906 (73.82) 2.625 (66.68)
QTE12-90 3/4 (19.05) QS750 10.00 (254.00) 3.875 (98.43) 3.5 (88.9)
Ri
H Typ.
35
Check Valves - QS Series
Pressures to 15,000 psi (1034 bar)
O-Ring Check Valves Provide unidirectional flow and tight shut-off for liquids and
gases with high reliability. When differential drops below crack-
ing pressure*, valve shuts off. (Not for use as relief valve.)
Materials: 316 Stainless Steel: Body, cover, poppet, cover
gland. 300 Stainless Steel: Spring.
Standard O-ring: Viton, for operation to 500 F (260C). Buna-
N or PTFE available for 250F (121C) or 400F (204C)
respectively; specify when ordering.
FLOW
*Cracking Pressure: 20 psi (1.38 bar) 30%. Springs for
higher cracking pressures (up to 100 psi (6.89bar)) available
on special order for O-ring style check valves only.
Ball Check Valves Prevent reverse flow where leak-tight shut-off is not
mandatory. When differential drops below cracking pressure,
valve closes. With all-metal components, valve can be used up
to 650F (343C). See Technical Information section for con-
nection temperature limitations. (Not for use as a relief valve.)
Ball and poppet are an integral design to assure positive,
in-line seating without chatter. Poppet is designed essentially
for axial flow with minimum pressure drop.
FLOW
Materials: 316 Stainless Steel: Body, cover, cover gland, ball
poppet. 300 Series Stainless Steel: Spring
CAUTION: While testing has shown O-Rings to provide satisfactory service life, both cyclic and shelf life may vary widely with differing service conditions, properties of reactants, pressure and temperature cycling
and age of the O-ring. FREQUENT INSPECTIONS SHOULD BE MADE to detect any deterioration, and O-rings replaced as required.
FEMALE END
Quick Set Medium Pressure
Connection
Size and Type 1/4 3/8 9/16 3/4 1/4 3/8 9/16 3/4 1
QS250 QS375 QS562 QS750 SF250CX SF375CX SF562CX SF750CX SF1000CX
Fits this Pressure 15,000 15,000 15,000 15,000 20,000 20,000 20,000 20,000 20,000
Female Rating (1034.20) (1034.20) (1034.20) (1034.20) (1378.93) (1378.93) (1378.93) (1378.93) (1378.93)
Connection PSI (bar)*
15,000
1/4 QS250 (1034.20) 15M46QQ 15M49QQ 15M412QQ 15M44Q6 15M46Q6 15M49Q6 15M412Q6 15M416Q6
15,000
Quick Set
3/8 QS375 (1034.20) 15M64QQ 15M69QQ 15M612QQ 15M64Q6 15M66Q6 15M69Q6 15M612Q6 15M616Q6
15,000
9/16 QS562 (1034.20) 15M94QQ 15M94QQ 15M912QQ 15M94Q6 15M96Q6 15M99Q6 15M912Q6 15M916Q6
15,000
3/4 QS750 (1034.20) 15M124QQ 15M126QQ 15M129QQ 15M124Q6 15M126Q6 15M129Q6 15M1212Q6 15M1216Q6
20,000
1/4 SF250CX (1378.93) 15M44KQ 15M46KQ 15M49KQ 15M412KQ
Medium Pressure
20,000
MALE END
(1034.20)
15,000
3/8 NPT (1034.20) 15M64NQ 15M66NQ 15M69NQ 15M612NQ
15,000
1/2 NPT (689.45) 15M84NQ 15M86NQ 15M89NQ 15M812NQ
10,000
3/4 NPT (689.45) 10M124NQ 10M126NQ 10M129NQ 10M1212NQ
10,000
1 NPT (689.45) 10M164NQ 10M166NQ 10M169NQ 10M1612NQ
Note:
All AE adapters are supplied complete with appropriate gland nuts and sleeves unless specified without.
NOTE: NPT (Pipe) connections
* The maximum pressure rating for an adapter is determined by the connection component with the NPT threads must be sealed using a high quality PTFE tape and/or
LOWEST pressure rating; that is, the two end connections and the tubing or pipe used, whichever is PTFE paste product. Refer to thread sealant manufacturers instructions
LOWER. on how to apply thread sealant.
Sealing performance may vary based on many factors such as pressure,
CAUTION: See appropriate pressure section in reference to proper selection of tubing.
temperature, media, thread quality, thread material, proper thread
engagement and proper use of thread sealant.
Customer should limit the number of times an NPT fitting is assembled
and disassembled because thread deformation during assembly will
result in deteriorating seal quality over time. When using only PTFE tape,
consider using thread lubrication to prevent galling of mating parts.
37
Quick Set Female Quick Set Female Quick Set Female Quick Set Female
to to to to
Quick Set Male Medium Pressure Male High Pressure Male National Pipe Male
FEMALE END
High Pressure National Pipe Thread (NPT)
1/4 3/8 9/16 1/4 3/8 1/2 3/4 1
F250C F375C F562C NPT NPT NPT NPT NPT
60,000 60,000 150,000 15,000 15,000 15,000 10,000 10,000
(4136.85) (4136.85) (10342.14) (1034.20) (1034.20) (1034.20) (689.45) (689.45)
AE Male/Female Adapters are available in a one-piece design. They are identical to the two piece designs in
length and can be ordered by adding the suffix - OP to the two piece adapter part numbers listed.
For prompt service, Parker Autoclave Engineers stocks select products. Consult factory.
38
QS Series
Male End Dimension inches (mm) Male End Dimension inches (mm)
Female Catalog Female Catalog
Fits this Fits this
End Number A Hex B End Number A Hex B
Connection Connection
QS375 QS250 15M64QQ .75 (19.1) 1.40 (35.6) QS750 QS250 15M124QQ
QS375 QS375 QS750 QS375 15M126QQ 1.50 (38.1) 2.53 (64.1)
QS375 QS562 15M69QQ QS750 QS562 15M129QQ 1.50 (38.1) 2.53 (64.1)
QS375 QS750 15M612QQ QS750 QS750
QS375 SF250CX 15M64Q6 QS750 SF250CX 15M124Q6
QS375 SF375CX 15M66Q6 QS750 SF375CX 15M126Q6
QS375 SF562CX 15M69Q6 QS750 SF562CX 15M129Q6
QS375 SF750CX 15M612Q6 QS750 SF750CX 15M1212Q6
QS375 SF1000CX 15M616Q6 QS750 SF1000CX 15M1216Q6
QS375 F250C 15M64Q3 QS750 F250C 15M124Q3
QS375 F375C 15M66Q3 QS750 F375C 15M126Q3
QS375 F562C 15M69Q3 QS750 F562C 15M129Q3
QS375 1/4 NPT 15M64Q8 .75 (19.1) 1.66 (42.2) QS750 1/4 NPT 15M124Q8
QS375 3/8 NPT 15M66Q8 1.00 (25.4) 1.78 (45.3) QS750 3/8 NPT 15M126Q8
QS375 1/2 NPT 15M68Q8 1.19 (30.1) 2.16 (54.8) QS750 1/2 NPT 15M128Q8 1.50 (38.1) 2.78 (70.5)
QS375 3/4 NPT 10M612Q8 QS750 3/4 NPT 10M1212Q8
QS375 1 NPT 10M616Q8 QS750 1 NPT 10M1216Q8
For prompt service, Parker Autoclave Engineers stocks select products. Maximum pressure rating is based on the lowest rating of any component.
Consult factory. Actual working pressure may be determined by tubing pressure rating, if lower.
Note: For pressure rating see selection chart.
All Dimensions for reference only and subject to change.
A A
HEX HEX
B B
39
QS Series
Male End Dimension inches (mm) Male End Dimension inches (mm)
Female Catalog Female Catalog
Fits this Fits this
End Number A Hex B End Number A Hex B
Connection Connection
SF250CX QS250 15M44KQ F250C QS250 15M44BQ .75 (19.1) 1.31 (33.3)
SF250CX QS375 15M46KQ F250C QS375 15M46BQ .81 (20.6) 1.56 (39.7)
SF250CX QS562 15M49KQ F250C QS562 15M49BQ
SF250CX QS750 15M412KQ F250C QS750 15M412BQ
SF562CX QS250 15M94KQ .94 (23.8) 1.75 (44.5) F562C QS250 15M94BQ 1.19 (30.1) 1.81(46.1)
SF562CX QS375 15M96KQ .94 (23.8) 1.75 (44.5) F562C QS375 15M96BQ 1.19 (30.1) 1.69 (42.9)
SF562CX QS562 15M99KQ 1.38 (34.9) 2.50 (63.5) F562C QS562 15M99BQ 1.38 (34.9) 2.32 (58.8)
SF562CX QS750 15M912KQ 1.50 (38.1) 3.25 (82.6) F562C QS750 15M912BQ
MP to QSS HP to QSS
A
HEX A
HEX
B
B
40
QS Series
NPT to QSS
A
HEX
41
QS Series
Parker Autoclave Engineers standard male-to-male one piece adapters are
available in multiple configurations. Standard male-to-male adapters are
machined from cold worked stainless steel.Contact your local Sales
Representative for optional information. The following tables list our
standard adapters with dimensions.
Ordering Procedure
15 MA Q4 H9
Pressure Male Available End Connections
(X 1000 psi) Adapter
Q4 - 1/4 QS Series M4 - 1/4 Medium Pressure H4 - 1/4 High Pressure P4 - 1/4 NPT * RH9 - 9/16 -18 Reverse High
Q6 - 3/8 QS Series M6 - 3/8 Medium Pressure H5 - 5/16 High Pressure P6 - 3/8 NPT RH12 - 3/4 -16 Reverse High
Q9 - 9/16 QS Series M9 - 9/16 Medium Pressure H6 - 3/8 High Pressure P8 - 1/2 NPT RH14 - 7/8 -14 Reverse High
Q12 - 3/4 QS Series M12 - 3/4 Medium Pressure H9 - 9/16 High Pressure P12 - 3/4 NPT RH16 - 1 -12 Reverse High
M16 - 1 Medium Pressure P16 - 1 NPT RH21 - 1-5/16 -12 Reverse High
*RH9 & RH14 - 40,000 psi (2758 bar), RH12 - 30,000 psi (2068 bar), RH16 - 26,000 psi (1793 bar), RH21 - 20,000 psi (1379 bar).
42
QS Series to Reverse High-Pressure Adapters
43
Tools, Installation, Operation and Maintenance - QSS Assembly Procedure
QSS Assembly Procedure
Fast, Positive Sealing for Pressures up to Torque values can be used for both initial setting and reas-
15,000 psi (1034 bar) sembly connections. See the following page for reassembly
1/4 & 3/8 Tubing Size (Standard setting operation) values and ranges.
See next page for setting with hydraulic tool. Initial setting torque
(Setting with hydraulic tool is recommended but not required). ft-lbs (NM)
1/4 40 (54.3)
1. Cut tubing to length and deburr. Allow extra length for
3/8 80 (108.5)
proper engagement (per table below).
Outside Diameter Extra Allowance** Completed Connection
Tube Size for Engagement
inches (mm) inches (mm) The illustration below shows the condition of sleeve and tub-
ing after completion of sleeve setting. The sleeve has cut
1/4 (6.35) 0.75 (19.05)
into the tubing as it moved forward into the tapered seat, up-
3/8 (9.53) 0.81 (20.64) setting material ahead of it and establishing a shoulder on the
2. Slip gland and sleeve onto tubing. tubing to provide positive mechanical support for the tubing
end-load. A properly set sleeve cannot be displaced back and
Note: Be sure to remove gland and sleeve from components forth along the tubing but may be rotated around the tubing.
and slide them onto the tubing before inserting the tubing into
the components.
Make sure larger end of sleeve is toward gland.
Push tubing into valve or fitting until it bottoms. Lubricate Position
gland nut threads to aid in assembly. If process tolerable, a Reference
The Parker Autoclave Engineers hydraulic sleeve set tool Tooling Installation and Changing Sizes
is designed for use with the QS Series glands, sleeves and To change tooling to another size only requires interchanging
Parker Autoclave Engineers tubing. This tool is required to set 2 parts.
the sleeve for the 9/16 and 3/4 sizes and suggested for the
1/4 and 3/8 sizes. It not only produces the required bite into 1. Loosen the 5/16" set screw that locks the threaded cap from
the tubing, it is much easier than trying to set the sleeve the rotating.
conventional method. 2. Using a 5/32" hex key to rotate and remove the threaded
The tool comes in a self contained portable, lockable case steel cap from the aluminum housing.
complete with hand or air pump, cap and dies for all sizes. 3. Turn the tool assembly upside down the remove the die
from inside the housing.
4. Install the die of the appropriate connection size you wish
to use. The solid side of the die should be facing down
towards the hydraulic cylinder.
5. Install the appropriate size cap to match the size of the die.
Insert cap with the 5/32" hex up. Rotate with a 5/32" hex key
until it bottoms out on the shoulder side of the housing.
6. Thread in the 5/16" set screw until it bottoms out on the
cap threads. Tighten set screw to prevent movement
during use.
Cap
Die
Features
Case Dimensions: 28W x 14.25H x 13.75D (711cm x
362cm x 292cm) Housing
46
Ordering Information
HST-912: Complete tool kit with hand pump (shown in photo)
HST-912TW: Complete tool kit with torque wrench and adapters
HST-912A: Complete tool kit with air-operated pump (Air operated
pump #P-1948)
HST-912ATW: Complete tool kit with torque wrench and adapters
Description Part #
Hydraulic Cylinder 90588
Gauge 90594
Adapter 90593
Base 101F-3407
Housing 101F-3408
Hydraulic Pump P-1893
Hose P-1894
1/4 Die HSTD4
1/4 Cap HSTC4
3/8 Die HSTD6
3/8 Cap HSTC6
9/16 Die HSTD9
9/16 Cap HSTC9
3/4 Die HSTD12
%
3/4 Cap HSTC12 7KUHDG
$ ' ULO
O
Tool Chest P-10011 )
1/4 QS250 29/64 (11.5) 1/2 -20 0.34 (8.6) 0.44 (11.1) 0.69 (17.5) 0.34 (8.6) 0.254 (16.4)
3/8 QS375 37/64 (14.7) 5/8 -18 0.38 (9.7) 0.47 (11.9) 0.75 (19.1) 0.48 (12.1) 0.380 (9.6)
9/16 QS562 7/8 (22.2) 15/16 -16 0.57 (14.5) 0.70 (17.8) 1.12 (28.5) 0.71 (18.0) 0.568 (14.2)
Weep
3/4 QS750 1-3/16 (30.15) 1-1/4 -18 0.82 (20.8) 1.00 (25.4) 1.56 (39.6) 0.94 (23.9) 0.75 (19.1) Hole
*For port diameter please see orifice sizes for specific valves and fittings. All threads are manufactured to a class 2A or 2B fit.
47
WARNING
FAILURE, IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS AND/OR SYSTEMS DESCRIBED HEREIN OR RELATED ITEMS CAN CAUSE DEATH, PERSONAL INJURY AND PROPERTY DAMAGE.
This document and other information from Parker Hannifin Corporation, its subsidiaries and authorized distributors provide product and/or system options for further investigation by users having technical
expertise. It is important that you analyze all aspects of your application and review the information concerning the product or system in the current product catalog. Due to the variety of operating conditions
and applications for these products or systems, the user, through its own analysis and testing, is solely responsible for making the final selection of the products and systems and assuring that all performance,
safety and warning requirements of the application are met. The products described herein, including without limitation, product features, specifications, designs, availability and pricing, are subject to change by
Parker Hannifin Corporation and its subsidiaries at any time without notice.
Offer of Sale
The items described in this document are available for sale by Parker Hannifin Corporation, its subsidiaries or its authorized distributors. Any sale contract entered by Parker will be governed by the provisions
stated in Parker's standard terms and conditions of sale (copy available upon request).
2013 Parker Hannifin Corporation | Autoclave Engineers is a registered trademark of the Parker Hannifin Corporation 02-1253BE January2013
Instrumentation Products Division Parker Hannifin Manufacturing Ltd. Caution! Parker Autoclave Engineers Valves, Fittings and Tools are
Autoclave Engineers Operation Instrumentation Products Division, Europe not designed to work with common commercial instrument tubing
and will only work with tubing built to Parker Autoclave Engineers
8325 Hessinger Drive Industrial Estate Whitemill
AES Specifications. Failure to do so will void warranty.
Erie, Pennsylvania 16509-4679 USA Wexford, Republic of Ireland
PH: 814-860-5700 FAX: 814-860-5811 PH: 353 53 914 1566
www.autoclave.com FAX: 353 53 914 1582 ISO-9001 Certified
Parker Autoclave Engineers
Non-rotating stem
Stem - can be re-adjusted Handles - powder
Prevents stem/seat galling when valve is to minimize backlash while coated stainless steel.
opened and closed. valve is in service.
4
This table is designed to allow quick selection of an appropriate air actuator based on valve style and size,
maximum system operating pressure and maximum available air pressure. For example, if the system operating
pressure is 25,000 psi (1723 bar) and the available air pressure is 60 psi (4.1 bar) and an air-to-open (spring fail
closed) valve is required, a 30VM or 60VM valve with a heavy duty air operator can be used.
Air-to-close
Medium Heavy Extra Heavy Single Stage Extra Heavy Two Stage
Valve O.D. System Air System Air System Air System Air
Series Tube Press. Press. Press. Press. Press. Press. Press. Press.
in. (mm) psi (bar) psi (bar) psi (bar) psi (bar) psi (bar) psi (bar) psi (bar) psi (bar)
9/16 8,600 100 10,000 55 10,000 45 10,000 20
(14.3) (593) (6.9) (690) (3.8) (690) (3.10) (690) (1.4)
3/4 4,800 100 10,000 100 10,000 70 10,000 35
10SM (19.1) (331) (6.9) (690) (6.9) (690) (4.83) (690) (2.4)
1 2,800 100 6,300 100 8,500 95 10,000 55
(25.4) (193) (6.9) (434) (6.9) (586) (6.55) (690) (3.79)
1/4 20,000 95 20,000 50 __ __ __ __
(6.35) (1380) (6.5) (1380) (3.5)
3/8 19,000 100 20,000 55 __ __ __ __
(9.53) (1310) (6.9) (1380) (3.8)
9/16 10,700 100 20,000 85 20,000 65 20,000 30
20SM (14.3) (734) (6.9) (1380) (5.9) (1380) (4.48) (1380) (2.1)
3/4 6,100 100 13,600 100 19,000 100 20,000 50
(19.1) (421) (6.9) (938) (6.9) (1310) (6.90) (1380) (3.4)
1 3,900 100 8,800 100 12,500 100 20,000 75
(25.4) (269) (6.9) (607) (6.9) (862) (6.90) (1380) (5.1)
1 __ __ __ __ __ __ 30,000 80
30SC (25.4) (2068) (5.5)
1/4 30,000 55 30,000 30 __ __ __ __
(6.35) (2068) (3.8) (2068) (2.0)
3/8 30,000 75 30,000 40 __ __ __ __
30VM (9.53) (2068) (5.2) (2068) (2.8)
9/16 30,000 75 30,000 40 __ __ __ __
(14.3) (2068) (5.2) (2068) (2.8)
9/16 40,000 90 40,000 45 __ __ __ __
40VM (14.3) (2758) (6.2) (2758) (3.1)
1/4 60,000 75 60,000 40 __ __ __ __
(6.35) (4137) (5.2) (4137) (2.8)
3/8 60,000 75 60,000 40 __ __ __ __
60VM (9.53) (4137) (5.2) (4137) (2.8)
9/16 60,000 90 60,000 45 __ __ __ __
(14.3) (4137) (6.2) (4137) (3.1)
Air-to-open
9/16 7,900 95 10,000 75 10,000 60 10,000 40
(14.3) (545) (6.6) (690) (5.1) (690) (4.13) (690) (2.8)
10SM 3/4 __ __ __ __ 10,000 95 10,000 60
(9.1) (690) (6.55) (690) (4.1)
1 __ __ __ __ 6,500 100 10,000 85
(25.4) (448) (6.90) (690) (5.9)
1/4 20,000 95 20,000 50 __ __ __ __
(6.35) (1380) (6.6) (1380) (3.4)
3/8 18,250 95 18,250 50 __ __ __ __
(9.53) (1258) (6.6) (1258) (3.4)
20SM 9/16 9,800 95 15,700 75 20,000 85 20,000 55
(14.3) (676) (6.6) (1082) (5.1) (1379) (5.86) (1380) (3.8)
3/4 __ __ 6,000 75 15,000 100 20,000 80
(19.1) (414) (5.1) (1034) (6.90) (1380) (5.5)
1 __ __ 4,000 75 10,000 100 20,000 100
(25.4) (276) (5.1) (690) (6.90) (1380) (6.9)
1 __ __ __ __ __ __ 30,000 100
30SC (25.4) (2068) (6.9)
1/4 30,000 75 30,000 40 __ __ __ __
(6.35) (2068) (5.2) (2068) (2.8)
3/8 30,000 95 30,000 50 __ __ __ __
30VM (9.53) (2068) (6.5) (2068) (3.5)
9/16 30,000 95 30,000 50 __ __ __ __
(14.3) (2068) (6.5) (2068) (3.5)
9/16 40,000 100 40,000 55 __ __ __ __
40VM (14.3) (2758) (6.9) (2758) (3.8)
1/4 60,000 95 60,000 50 __ __ __ __
(6.35) (4137) (6.5) (4137) (3.5)
60VM 3/8
(9.53)
60,000
(4137)
95
(6.5)
60,000
(4137)
50
(3.5)
__ __ __ __
5
Couplings
The couplings shown here permit the joining of any combination of standard size Parker Autoclave Engineers
tubing with female-to-female couplings. Other couplings available on special order. See valve fitting and tubing catalog for
complete selection.
A B Connection
Connection
How to use the P-AE Medium Pressure P-AE High Pressure
Ordering Chart: Tube Conn. Pressure 1/4 3/8 9/16 3/4 1 1 1/4 3/8 9/16 9/16
Size Type psi*(bar) (6.35) (9.53) (14.3) (19.1) (25.4) (25.4) (6.35) (9.53) (14.3) (14.3)
in.(mm) SF250CX SF375CX SF562CX SF750CX SF1000CX F1000C43 F250C F375C F562C F562C40
1. Locate A connection in the
vertical column. 1/4 SF250 20,000 20FX 20F 20F 20F 20F 20F 20F 20F 20F
2. Locate the desired B connection
P-AE Medium Pressure
(6.35) CX (1380) 4466 4666 4966 41266 41666 41663 4463 4663 4963
across the top of the chart. 3/8 SF375 20,000 20FX 20F 20F 20F 20F 20F 20F 20F
(9.53) CX (1380) 6666 6966 61266 61666 61663 6463 6663 6963
3. The catalog number of the
required coupling is located at the 9/16 SF562 20,000 20FX 20F 20F 20F 20F 20F
(14.3) CX (1380) 9966 91266 91666 9463 9663 9963
intersection of the two columns.
3/4 SF750 20,000 20FX 20F 20F 20F 20F
(19.1) CX (1380) 12 121666 12463 12663 12963
Male/Female Adapters
Male/female adapters are designed to adapt a female connection direct to another size and/or type of connection.
In selecting an adapter involving two different sized connections, the larger connection should be on the male end where it is
possible to maximize the mechanical strength of the adapter. See valve fitting and tubing catalog for complete selection.
is located at intersection of columns. 3/8 SF375CX 20,000 20M64K6 20M69K6 20M612K6 20M616K6 20M64K3 20M66K3 20M69K3
(9.53) (1380)
others. 1/4
(6.35)
F250C 60,000
(4140)
20M44B6 20M46B6 20M49B6 20M412B6 60M46B3 60M49B3
Materials 3/8
(9.53)
F375C 60,000
(4140)
20M64B6 20M66B6 20M69B6 20M612B6 20M616B6 43M416B6 60M64B3 60M69B3
All Parker Autoclave Engineers adapt-
ers are precisionmachined from cold- 9/16 F562C 60,000 20M94B6 20M96B6 20M99B6 20M912B6 20M916B6 43M616B6 60M94B3 60M96B3
(14.3) (4140)
worked Type 316 stainless steel. Other
9/16 F562C40 40,000 20M912G6 43M916B6
materials available on special order. (14.3) (2758)
*Pressure Rating - The pressure rating of Parker Autoclave Engineers couplings is based on the lower rated connection used.
6
Fittings, Components & Accessories
Connection Sizes Pressure Rating Connection Styles
in. (mm) psi (bar)
Coned-and-threaded type for high
Medium 1/4 to 1 to 20,000
strength and repeated make-up.
Anti-vibration collet gland available.
Pressure (6.35 to 25.4) (1380)
In line collar and gland to minimize
block thickness.
O.D. Pressure
Tube Size Rating Straight Union Bulkhead
in. (mm) psi (bar) Elbow Tee Cross Coupling Coupling Coupling
1/4 (6.35) 20,000 (1380) CLX4400 CTX4440 CXX4444 20FX4466 20UFX4466 20BFX4466
O.D. Pressure
Tube Size Rating
In. (mm) psi (bar) Gland Collar Plug O-Ring Ball Excess Flow Dual Disc Cup-Type Safety Heads
1/4 (6.35) 20,000 (1380) CGLX40 CCLX40 CPX40 CXO4400 CXB4400 CXK4402 - CXF4 CSX4600*
Medium 3/8 (9.53)
9/16 (14.3)
20,000 (1380)
20,000 (1380)
CGLX60
CGLX90
CCLX60
CCLX90
CPX60
CPX90
CXO6600
CXO9900
CXB6602
CXB9900
CXK6602
CXK9902
-
CLFX9900
CXF6
CXF9
CSX6600*
CSX9600*
Pressure 3/4 (19.1) 20,000 (1380) CGLX120 CCLX120 CPX120 CXO12 CXB12 CXK1202 - CXF12 -
1 (25.4) 20,000 (1380) CGLX160 CCLX160 CPX160 CXO16 CXB16 CXK1602 - CXF16 -
1 (25.4) 43,000 (2964) CGLX160 CCLX160 43CP160 43CO16 43CB16 - - - -
High 9/16 (14.3)
1/4 (6.35)
40,000 (2760)
60,000 (4140)
AGL90
AGL40
ACL90
ACL40
AP90
AP40
-
CKO4400
-
CB4401
-
CK4402
-
CLF4400
-
CF4
-
CS4600*
Pressure 3/8 (9.53) 60,000 (4140) AGL60 ACL60 AP60 CKO6600 CB6601 CK6602 CLF6600 CF6 CS6600*
9/16 (14.3) 60,000 (4140) AGL90 ACL90 AP90 CKO9900 CB9901 CK9902 CLF9900 CF9 CS9600*
7
Tubing
Parker Autoclave Engineers offer a complete selection of Austenetic,
cold drawn stainless steel tubing designed to match the performance
standards of Parker Autoclave Engineers valves and fittings.
Parker Autoclave Engineers tubing is manufactured specifically
for high pressure applications requiring both strength and corrosion resistance.
The tubing is furnished in random lengths between 20 and 26.5 feet
(6.1 and 8.0 meter).
Note: For autofrettage tubing, add suffix ESR42 to the tubing part number.
8
Coned-and-threaded Nipples
For rapid system make-up, Parker Autoclave Engineers
supplies pre-cut, coned-and-threaded nipples in various
sizes and lengths for Parker Autoclave Engineers valves
and fittings.
Special lengths
In addition to the standard lengths listed in the table
below, nipples are available in any custom length.
Consult factory.
Materials
Catalog numbers in table refer to Type 316 stainless steel, unless specified.
Working Tube Size in.(mm) Catalog Number
Fits Pressure at
Connection 100F(38C) 2.75 3 4 6 8 10 12
Type O.D. I.D. psi(bar) Length Length Length Length Length Length Length
SF250CX 1/4 (6.35) .109 (2.77) 20,000 (1380) CNX4402 CNX4403 CNX4404 CNX4406 CNX4408 CNX44010 CNX44012
SF375CX 3/8 (9.53) .203 (5.16) 20,000 (1380) CNX6603 CNX6604 CNX6606 CNX6608 CNX66010 CNX66012
SF562CX 9/16 (14.3) .312 (7.92) 20,000 (1380) CNX9904 CNX9906 CNX9908 CNX99010 CNX99012
SF562CX 9/16 (14.3) .359 (9.12) 15,000 (1034) CNLX9904 CNLX9906 CNLX9908 CNLX99010 CNLX99012
SF750CX 3/4 (19.1) .438 (11.1) 20,000 (1380) CNX1204 CNX1206 CNX1208 CNX12010 CNX12012
SF750CX 3/4 (19.1) .515 (13.1) 15,000 (1034) CNLX1204 CNLX1206 CNLX1208 CNLX12010 CNLX12012
SF1000CX 1 (25.4) .562 (14.3) 20,000 (1380) CNX1606 CNX1608 CNX16010 CNX16012
SF1000CX 1 (25.4) .688 (17.5) 15,000 (1034) CNLX1606 CNLX1608 CNLX16010 CNLX16012
F250C 1/4 (6.35) .083 (2.11) 60,000 (4140) CN4402 CN4403 CN4404 CN4406 CN4408 CN44010 CN44012
F375C 3/8 (9.53) .125 (3.18) 60,000 (4140) CN6603 CN6604 CN6606 CN6608 CN66010 CN66012
F562C 9/16 (14.3) .187 (4.78) 60,000 (4140) CN9904 CN9906 CN9908 CN99010 CN99012
F562C40 9/16 (14.3) .250 (6.35) 40,000 (2760) 40CN9904-316 40CN9906-316 40CN9908-316 40CN99010-316 40CN99012-316
F1000C43 1 (25.4) .438 (11.1) 43,000 (2964) 43CN1606 43CN1608 43CN16010 43CN16012
Note: Add -316 or -304 to catalog number for material choice if not shown.
Line contact
3/4 (19.1) KCBGLX120-316MC - sealing
1 High Pressure to 43,000 psi (2964 bar) *AE Collar not included in complete assembly.
9
P-AE Instrument Quality Gauges
Materials and features
Accuracy within 0.5% of full scale range
Plastic dial cover/solid front aluminum alloy case
Blow-out back panel for pressure relief in the event of Bourdon tube failure
316 Stainless steel Bourdon tubes**
Precision stainless steel movement for accuracy and resistance to atmospheric corrosion
Pointer zero adjustment located on front of gauge behind dial cover for convenience
10
Specialty Products
Ball Valves
Parker Autoclave Engineers ball valves are designed for
on-off, high flow applications. With the valve fully open the
straight-through design minimizes pressure drop.
Parker Autoclave Engineers ball valves are economical
and easy to maintain for long service life. One piece,
trunnion mounted style stem design eliminates
shear failure and reduces the effects of side
loading found in two piece designs. Seat glands
may be retightened for extended use.
Operating torque is low to reduce wear and
extend the life of parts.
The Parker Autoclave Engineers ball valve is
designed to operate safely at pressures up to
20,000 psi @ 200 F (1380 bar @ 93 C) and
temperatures up to 500 F @ 5,000 psi (260 C @ 345 bar).
Connection
Size & Type Pressure Rating
(inches) PSIG @ 100F (bar @ 38C)
11
Specialty Products
Manifold Block
Specialty pressure manifolds minimize space requirements and reduce installation time necessary to plumb a
pressure system. In addition, by reducing the number of components used in a system, manifolds reduce the
number of potential leak joints.
Parker Autoclave Engineers will design and build pressure manifolds to meet specific installation, layout and pres-
sure requirements. These manifolds are capable of withstanding pressures from vacuum to 60,000 psi (4137 bar),
and are available in a variety of materials and sizes. Among the pressure connections that can be incorporated
are Parker Autoclave Engineers' low, medium and high pressure, NPT, SAE, BSP and others. Transitions in sys-
tem line sizes and tubing pressure series can be accomplished through a specialty manifold. These manifolds are
appropriate wherever pressure tubing systems are utilized.
12
Tools
P-AE Micrometer Adjustable Torque Wrench
P-1680 20 to 150 ft. lbs. (27 to 203 Nm)
91020 75 to 250 ft. lbs. (102 to 339 Nm)
Accurate tightening for all Parker Autoclave Engineers valve packing glands and tube nuts is essential. The
wrench can be adjusted to the ranges shown and is used with interchangeable wrench adapters for hex sizes
from 1/2" through 1-7/8". Part numbers for wrench adapters are listed on chart.
Packing Gland or 1/2 9/16 5/8 3/4 13/16 7/8 15/16 1 1-1/16 1-3/16 1-3/8 1-1/2 1-7/8
Tube Nut Hex Size
in. (mm) (12.7) (14.3) (15.9) (19.05) (20.6) (22.2) (23.8) (25.4) (27) (30.2) (34.9) (38.1) (47.6)
Wrench Adapter
Number P-1681 P-1682 P-1683 P-9813 P-1685 P-1686 P-1687 P-9901 P-1688 P-1689 P-1690 P-6040 P-10076
13
Tools
Manual Coning & Threading Tools
Parker Autoclave Engineers manufactures a manual coning tool for optimum coning performance with tubing
sizes up to 9/16" (14.3 mm) O.D. This is a precision quality manual tool to permit on-site end preparation for
AE medium and high pressure tubing installations. Interchangeable collets for each size tubing provide proper
centering of tubing. The cutting feed arrangement permits the operator to control the depth of cut to assure
against work hardening effects. Interchangeable tool steel cutting blades are used in pairs to assure more
accurate and faster coning and are designed to square-off and finish the tube as the cone is completed.
There is a provision for applying metal cutting lubricants to the cutting zone.
Coning tool
housing
Collet nut
Tube Size Coning Tools and Components Catalog Number Threading Tools and Components Catalog Number
Tool Tool
with Coning with Threading Die
O.D. I.D. Collet & Blades Die & Tool Guide
in.(mm) in.(mm) Blades Collet (set of 2) Bushing Only Order No. Size-type* Bushing
PAE Medium Pressure
1/4 (6.35) .109 (2.77) MCTM4 90248 101F-1577 402A 402 P-0214 1/4-28 1010-0343
3/8 (9.53) .203 (5.16) MCTM6 90250 101F-1601 402C 402 P-0215 3/8-24 1010-0344
9/16 (14.3) .312 (7.92) MCTM920 90251 1010-5218 402E 402 P-0216 9/16-18 1010-0345
9/16 (14.3) .359 (9.12) MCTM910 90251 101A-1897 402E 402 P-0216 9/16-18 1010-0345
1/4 (6.35) .083 (2.11) MCTH4 90248 101F-3939 402A 402 P-0214 1/4-28 1010-0343
PAE High Pressure
3/8 (9.53) .125 (3.18) MCTH6 90250 101F-1578 402C 402 P-0215 3/8-24 1010-0344
9/16 (14.3) .188 (4.78) MCTH960 90251 1010-0883 402E 402 P-0216 9/16-18 1010-0345
9/16 (14.3) .250 (6.35) MCTH940 90251 101C-7214 402E 402 P-0216 9/16-18 1010-0345
14
Flow Calculations
Coefficient of flow (CV) for a valve is the volume of water in U.S. gallons per minute at room temperature...which
will flow through the valve with the stem fully open...with a pressure drop of 1 psi across the valve. CV is the valve
sizing factor that permits selection of the appropriate valve to meet the flow requirements of a given fluid system.
The CV values shown on the valve ordering pages represent the full-open CV for that valve. In determining
estimated capacity, this CV value should be used in the formulas which follow.
Flow Formulas
Liquids
V = CV P1 - P2
q Flow, U.S. gal./min. SGF
q Flow, lb./hr. W = 500 CV (P1 - P2) /SGF
Gases **
Q = 42.2 CV (P1 - P2) (P1 + P2)
q Flow, SCFH SGF
*
Q = 963 CV (P1 - P2) (P1 + P2)
q Flow, SCFH (temperature corrected)
SGF TF
*
q Flow, lb./hr. W = 3.22 CV (P1 - P2) (P1 + P2)/SG
Saturated Steam
*
q Flow, lb./hr. W = 2.1 CV (P1 - P2) (P1 + P2)
Methane 0.553
*Effect of flowing temperatures on gas flow are minimal for temperatures between 30F
Nitrogen 0.966 and 150F. Correction should be included if temperatures are higher or lower.
Oxygen 1.103 **Where outlet pressure P2 is less than 1/2 inlet pressure P1, the term:
Propane 1.562 (P1 - P2) (P1 + P2): becomes 0.87 P1.
Sulpher dioxide 2.208
Note: Maximum CV values in this catalog have been determined in accordance with the Fluid
Controls Institute report FCI 58-2. Recommended Voluntary Standards for Measurement
Procedure for Determining Control Valve Flow Capacity, including procedure, design of the
test stand and evaluation of the data.
15
Connections
P-AE Medium Pressure SFCX
Dimensions
Tube inches (mm) 60
O.D. Connection Type
in. (mm) B
A B C D F H Thread
A
Drill
1/4 SF250CX20 25/64 7/16 -20 .28 .50 .19 .109 F
(6.35) (7.11) (12.7) (4.83) (2.77)
C
3/8 SF375CX20 33/64 9/16 -18 .38 .62 .31 .203 D
(9.53) (9.65) (15.7) (7.87) (5.16)
9/16 SF562CX20 3/4 13/16 -16 .44 .75 .50 .359 5
(14.3) (11.2) (19.1) (12.7) (9.12)
Weep
3/4 SF750CX20 61/64 3/4 -14z .50 .94 .62 .516 hole
(19.1) (12.7) (23.9) (15.7) (13.1) H
Note: All dimensions are shown for reference only and should not be considered as actual machining dimensions.
*For port Diameter please see orifice sizes for specific valves and fittings.
All threads are manufactured to a class 2A or 2B fit.
WARNING
FAILURE, IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS AND/OR SYSTEMS DESCRIBED HEREIN OR RELATED ITEMS CAN CAUSE DEATH, PERSONAL INJURY AND PROPERTY DAMAGE.
This document and other information from Parker Hannifin Corporation, its subsidiaries and authorized distributors provide product and/or system options for further investigation by users having technical
expertise. It is important that you analyze all aspects of your application and review the information concerning the product or system in the current product catalog. Due to the variety of operating conditions
and applications for these products or systems, the user, through its own analysis and testing, is solely responsible for making the final selection of the products and systems and assuring that all performance,
safety and warning requirements of the application are met. The products described herein, including without limitation, product features, specifications, designs, availability and pricing, are subject to change by
Parker Hannifin Corporation and its subsidiaries at any time without notice.
Offer of Sale
The items described in this document are available for sale by Parker Hannifin Corporation, its subsidiaries or its authorized distributors. Any sale contract entered by Parker will be governed by the provisions
stated in Parker's standard terms and conditions of sale (copy available upon request).
2013 Parker Hannifin Corporation | Autoclave Engineers is a registered trademark of the Parker Hannifin Corporation 02-0015BE January2013
tubes haute pression bars (15,000 psi) dans toutes les tailles. Pour plus
dinformations, demander un catalogue VFT complet ou
contacter le reprsentant Autoclave Engineers.
Depuis sa cration en 1945, Autoclave Engineers sest consacr
la fabrication de robinetterie haute pression totalement fiable,
pour un fonctionnement en toute scurit, malgr des variations
extrmes de temprature et de pression et dans des conditions
environnementales parfois difficiles. Aujourdhui, Autoclave
Engineers est le leader mondial de la fourniture des vannes,
raccords et tubes haute pression, et du service aux industries
utilisant les hautes pressions.
Alors que les vannes, raccords et tubes Autoclave sont
largement rputs pour leur aptitude travailler jusqu des
pressions pouvant excder 6895 bars (100000 psi), il existe
aussi une ligne de produits basse pression pour les applications
allant jusqu 750 bar (11500 psi). Utilisant une simple bague
sertie, qui permet une mise en oeuvre rapide et parfaitement
tanche; ce raccordement est disponible de 1/16 1/2.
Vannes, raccords et tubes basse pression
Toutes les vannes basse pression Autoclave sont des vannes de
type bloc/pointeau. La conception du pointeau dit non tournant
vite le grippage et dventuelles rayures.
De plus le contact mtal/mtal entre sige et pointeau garantit
une tanchit aux bulles, ainsi quune longvit accrue en cycle
marche/arrt du pointeau et de son sige mme dans un flux
abrasif et une excellente rsistance la corrosion de lensemble.
Trois styles de vannes basse pression sont disponibles: les
sries 10V, SW et MVE/MV.
Types de circuits proposs :
2-Voies droites
2-Voies dangle
3-Voies/ 2 sous pression
3-Voies/ 1 sous pression
2-Voies dangle sige remplaable (non disponible en MVE/MV)
3-Voies/ 2 pointeaux
Trois types de pointeaux sont disponibles. Un pointeau en V est
propos quand lapplication demande une simple ouverture/
fermeture, tanchit mtal/mtal, avec possibilit douverture
rapide. Si lapplication ncessite un meilleur contrle du dbit,
AE propose un pointeau de rgulation non tournant en 2 parties.
Pour les rgulations de dbit les plus prcises, Autoclave
recommande un pointeau de rgulation micromtrique.
Une gamme complte de tubes et raccords, ainsi que des
produits spciaux sont disponibles, afin de pouvoir fournir tous
les composants ncessaires pour notre ligne basse pression.
Les composants Autoclave sont proposs de faon standard en
Inox 316, mais peuvent tre commands en option en diffrents
matriaux tels que: Hastelloy B et C, Inconel, Monel, Nickel ou
Titane.
Pour plus dinformation ou pour commander un catalogue VFT
complet, contactez votre reprsentant Autoclave ou directement
notre site www.autoclaveengineers.com.
2
Vannes fermeture manuelle
Les vannes Autoclave sont conues et fabriques pour fonctionner des pressions allant jusqu 10342 bar
(150,000 psi). Leurs caractristiques spcifiques assurent un fonctionnement sr et fiable sous des contraintes
trs varies.
Pointeau non tournant
Pointeau - peut tre rajust
vite la dtrioration par grippage du pointeau/ pour rduire le jeu latral
Poinges - de
construction solide.
sige, louverture et la fermeture de la vanne. pendant que la vanne
Disponibles en dif-
fonctionne
frentes couleurs
Etancht mtal/mtal crou de presse toupe -
bronze daluminium plaqu
Assure une fermeture tanche aux bulles, une dure nickel, rduit le couple de
de vie pointeau/sige plus longue mme dans un fermeture du pointeau Frein dcrou - vite le desserrage
de lcrou presse toupe
flux abrasif, une longvit accrue en cycle marche/ Bute de pallier -
inox plaqu argent pour
arrt et une excellente rsistance la corrosion. rduire le frottement du
pointeau Orifices pour vis de montage
Presse-toupe PTFE encastr Perage pour montage sur
cornire - standard
sur panneau- standard sur
chaque vanne
Accrot la fiabilit de ltancht entre pointeau sur toutes les vannes
et corps de vanne. Les matriaux du fourreau du Presse toupe en
Corps de vanne tir froid dessous du filtetage
pointeau et de lcrou du presse toupe augmentent - autorise des pressions du pointeau - rglable;
leves pour des dimensions
la dure de vie du filetage et rduisent le couple de corps de vanne rduites
spare les filetages (et
leurs lubrifiants) du fluide
ncessaire pour actionner la vanne. vhicul
Pointeau non tournant
Haute 9/16
(14.3)
30,000
(2070)
.33 Vee 30VM9071 30VM9072
Reg 30VM9081 30VM9082
30VM9073
30VM9083
30VM9074
30VM9084
30VM9872
30VM9882
30VM9075
30VM9085
Pression 9/16
(14.3)
40,000
(2760)
.28 Vee 40VM9071 40VM9072
Reg 40VM9081 40VM9082
40VM9073
40VM9083
40VM9074
40VM9084
40VM9872
40VM9882
40VM9075
40VM9085
1/4 60,000 .08 Vee 60VM4071 60VM4072 60VM4073 60VM4074 60VM4872 60VM4075
(6.35) (4140) Reg 60VM4081 60VM4082 60VM4083 60VM4084 60VM4882 60VM4085
3/8 60,000 .09 Vee 60VM6071 60VM6072 60VM6073 60VM6074 60VM6872 60VM6075
(9.53) (4140) Reg 60VM6081 60VM6082 60VM6083 60VM6084 60VM6882 60VM6085
9/16 60,000 .14 Vee 60VM9071 60VM9072 60VM9073 60VM9074 60VM9872 60VM9075
(14.3) (4140) Reg 60VM9081 60VM9082 60VM9083 60VM9084 60VM9882 60VM9085
*les CV indiqus le sont pour les modles 2-voies droites. Pour 2-voies dangle, augmenter le CV de 50%.
3
Oprateurs Pneumatiques (pour Vannes Manuelles AE)
Trois tailles doprateurs pneumatiques ( service moyen, fort ou extra fort ) sont proposes pour la commande
douverture-fermeture automatique distance des vannes AE de moyenne et haute pression. Les oprateurs
pneumatiques sont disponibles en deux configurations: ouverture par pression dair (vanne normalement
ferme) ou fermeture par pression dair (vanne normalement ouverte.)
4
Ce tableau est destin permettre deffectuer la selection rapide dun oprateur pneumatique partir de la taille
et du type de la vanne quiper, de la pression de service maximum du systme et de la pression dair maximum
disponible. Par exemple, si la pression de travail du systme est 1723 bar (25000 psi), la pression dair disponible
est de 4,1 bar (60psi) et une vanne normalement ferme est ncessaire, une vanne 30VM ou 60VM avec un
oprateur pneumatique de classe fort peut tre utilise.
Normalement ouvert
ext. Moyen Fort Extra Fort Piston Simple Extra Fort Piston Double
du tube Pression Pression Pression Pression Pression Pression
Type de pouces Pression Pression
du systme dair du systme dair du systme dair du systme dair
Vanne (mm)
psi (bar) psi (bar) psi (bar) psi (bar) psi (bar) psi (bar) psi (bar) psi (bar)
9/16 8,600 100 10,000 55 10,000 45 10,000 20
(14.3) (593) (6.9) (690) (3.8) (690) (3.10) (690) (1.4)
10SM 3/4
(19.1)
4,800
(331)
100
(6.9)
10,000
(690)
100
(6.9)
10,000
(690)
70
(4.83)
10,000
(690)
35
(2.4)
1 2,800 100 6,300 100 8,500 95 10,000 55
(25.4) (193) (6.9) (4346) (6.9) (586) (6.55) (690) (3.79)
1/4 20,000 95 20,000 50 __ __ __ __
(6.35) (1380) (6.5) (1380) (3.5)
3/8 19,000 100 20,000 55 __ __ __ __
(9.53) (1310) (6.9) (1380) (3.8)
20SM 9/16
(14.3)
10,700
(734)
100
(6.9)
20,000
(1296)
85
(5.9)
20,000
(1380)
65
(4.48)
20,000
(1380)
30
(2.1)
3/4 6,100 95 13,600 100 19,000 100 20,000 50
(19.1) (421) (6.5) (938) (6.9) (1310) (6.90) (1380) (3.4)
1 3,900 100 8,800 100 19,000 95 20,000 75
(25.4) (269) (6.9) (607) (6.9) (1310) (6.55) (1380) (5.1)
1 __ __ __ __ __ __ 30,000 80
30SC (25.4) (2068) (5.5)
1/4 30,000 55 30,000 30 __ __ __ __
(6.35) (2068) (3.8) (2068) (2.0)
3/8 30,000 75 30,000 40 __ __ __ __
30VM (9.53) (2068) (5.2) (2068) (2.8)
9/16 30,000 75 30,000 40 __ __ __ __
(14.3) (2068) (5.2) (2068) (2.8)
9/16 __ __ 40,000 45 __ __ __ __
40VM (14.3) (2758) (3.1)
1/4 60,000 75 60,000 40 __ __ __ __
(6.35) (4137) (5.2) (4137) (2.8)
3/8 60,000 75 60,000 40 __ __ __ __
60VM (9.53) (4137) (5.2) (4137) (2.8)
9/16 60,000 90 60,000 45 __ __ __ __
(14.3) (4137) (6.2) (4137) (3.1)
Normalement ferm
9/16 7,900 95 10,000 75 10,000 60 10,000 40
(14.3) (1380) (6.9) (1380) (5.1) (690) (4.13) (690) (2.8)
10SM 3/4
(9.1)
__ __ __ __ 10,000
(690)
95
(6.55)
10,000
(690)
60
(4.1)
1 __ __ __ __ 6,500 100 10,000 85
(25.4) (448) (6.90) (690) (5.9)
1/4 20,000 95 20,000 50 __ __ __ __
(6.35) (1380) (6.6) (1380) (3.4)
3/8 18,250 95 18,250 50 __ __ __ __
(9.53) (1258) (6.6) (1258) (3.4)
9/16 9,800 95 15,700 75 20,000 85 20,000 55
20SM (14.3) (676) (6.6) (948) (5.1) (1380) (5.86) (1380) (3.8)
3/4 __ __ 6,000 75 15,000 100 20,000 80
(19.1) (414) (5.1) (1034) (6.90) (1380) (5.5)
1 __ __ 4,000 75 10,000 100 20,000 100
(25.4) (276) (5.1) (690) (6.90) (1380) (6.9)
1 __ __ __ __ __ __ 30,000 100
30SC (25.4) (2068) (6.9)
1/4 30,000 75 30,000 40 __ __ __ __
(6.35) (2068) (5.2) (2068) (2.8)
30VM 3/8
(9.53)
30,000
(2068)
95
(6.5)
30,000
(2068)
50
(3.5)
__ __ __ __
5
Raccords Union
Les raccords union prsents ici permettent de raccorder toutes les combinaisons de tube Autoclave de taille
standard par lintermdiaire de raccordements femelle-femelle. Dautre raccords sont disponibles sur commande
spciale.
Connexion Connexion B
A AE Moyenne Pression AE Haute Pression
Comment utiliser le 1/4 3/8 9/16 3/4 1 1 1/4 3/8 9/16 9/16
tableau: ext.
du tube
Type
de
Pression
psi* (6.35) (9.53) (14.3) (19.1) (25.4)
SF250CX SF375CX SF562CX SF750CX SF1000CX
(25.4)
F1000
(6.35)
F250C
(9.53)
F375C
(14.3)
F562C
(14.3)
F562C40
pouces connexion (bar)
(mm) CX43
1. Localiser la connexion A dans la
colonne verticale. 1/4 SF250CX 20,000 20FX 20F 20F 20F 20F 20F 20F 20F 20F
AE Moyenne Pression
(6.35) (1380) 4466 4666 4966 41266 41666 41666 4463 4663 4963
2. Localiser la connexion B sur la
partie haute du tableau. 3/8 SF375CX 20,000 20FX 20F 20F 20F 20F 20F 20F 20F
(9.53) (1380) 6666 6966 61266 61666 61666 6463 6663 6963
3. La rfrence du raccord
9/16 SF562CX 20,000 20FX 20F 20F 20F 20F 20F
ncessaire est situe (14.3) (1380) 9966 91266 91666 9463 9663 9963
lintersection des 2 colonnes.
3/4 SF750CX 20,000 20FX 20F 20F 20F 20F
(19.1) (1380) 12 121666 12463 12663 12963
Adaptateurs Mle/Femelle
Les adaptateurs Mle/Femelle sont conus pour raccorder directement une connexion femelle une autre taille
ou un autre type de connexion.
En choisissant un adaptateur comportant des connexions de tailles diffrentes, la connexion de plus gros diamtre devrait tre
sur lextrmit mle o la rsistance mcanique de ladaptateur peut tre la plus forte.
1/4(6.35) 3/8(9.53) 9/16(14.3) 3/4(19.1) 1(25.4) 1(25.4) 1/4(6.35) 3/8(9.53) 9/16(14.3) 9/16 (14.3)
1. Localiser lextremit MLE dans la SF250CX SF375CX SF562CX SF750CX SF1000CX F1000C43 F250C F375C F562C F562C40
colonne verticale. Extrmit pour conn. Pression 20,000 20,000 20,000 20,000 20,000 43,000 60,000 60,000 60,000 40,000
femelle
2. Localiser lextremit FEMELLE Mle
corresp. psi*(bar) (1380) (1380) (1380) (1380) (1380) (2964) (4140) (4140) (4140) (2758)
dsire pour ladaptateur sur la
1/4 SF250CX 20,000 20M46K6 20M49K6 20M412K6 20M416K6 20M44K3 20M46K3 20M49K3
partie haute du tableau. (6.35) (1380)
AE Moyenne Pression
3. La rfrence catalogue de 3/8 SF375CX 20,000 20M64K6 20M69K6 20M612K6 20M616K6 20M64K3 20M66K3 20M69K3
l adaptateur ncessaire est situe (9.53) (1380)
lintersection des 2 colonnes. 9/16 SF562CX 20,000 20M94K6 20M96K6 20M912K6 20M916K6 20M94K3 20M96K3 20M99K3
(14.3) (1380)
Autres adaptateurs 3/4 SF750CX 20,000 20M124K6 20M126K6 20M129K6 20M1216K6 20M124K3 20M126K3 20M129K3 20M129K40
AE fournit plusieurs autres types (19.1) (1380)
dadaptateurs sur commande spciale. 1 SF1000CX 20,000 20M164K6 20M166K6 20M169K6 20M1612K6 20M1616K6 20M164K3 20M166K3 20M169K3
(25.4) (1380)
Cel inclut aussi les connexions du type
AE UniVersa-Lok, douille souder sur 1 F1000C43 43,000 43M164B3 43M166B3 43M169B3 43M168B40
(25.4) (2964)
le ext du tube ou taille nominale du
AE Haute Pression
1/4 F250C 60,000 20M44B6 20M46B6 20M49B6 20M412B6 43M416B6 60M46B3 60M49B3
tube, connexion mle ou femelle (6.35) (4140)
AN et autres. 3/8 F375C 60,000 20M64B6 20M66B6 20M69B6 20M612B6 20M616B6 43M616B6 60M64B3 60M69B3
(9.53) (4140)
Matires 9/16 F562C 60,000 20M94B6 20M96B6 20M99B6 20M912B6 20M916B6 43M916B6 60M94B3 60M96B3
Tous les adaptateurs AE sont usins (14.3) (4140)
avec prcision partir dInox 316 tir 9/16 F562C40 40,000 20M912G6
(14.3) (2758)
froid. Autres matires disponible sur
commande spciale.
*Pression- les valeurs de pression des raccords AE sont bases la valeur de la connexion la plus faible.
6
Raccords, Composants & Accessoires
ext. Valeurs de
Tube Pression Raccord Raccord Traverse
pouces (mm) psi (bar) Coude T Croix union union droit de cloison
1/4 (6.35) 20,000 (1380) CLX4400 CTX4440 CXX4444 20FX4466 20UFX4466 20BFX4466
Moyenne 3/8
9/16
(9.53)
(14.3)
20,000 (1380)
20,000 (1380)
CLX6600
CLX9900
CTX6660
CTX9990
CXX6666
CXX9999
20FX6666
20FX9966
20UFX6666
20UFX9966
20BFX6666
20BFX9966
Pression 3/4 (19.1) 20,000 (1380) CLX12 CTX12 CXX12 20FX12 20UFX12 20BFX12
1 (25.4) 20,000 (1380) CLX16 CTX16 CXX16 20FX16 20UFX16 20BFX16
1 (25.4) 43,000 (2964) 43CLX16 43CTX16 43CXX16 43FX16 43UFX16 43BFX16
Haute 9/16
1/4
(14.3)
(6.35)
40,000 (2760)
60,000 (4140)
40CL9900
CL4400
40CT9990
CT4440
40CX9999
CX4444
40F9933
60F4433
40UF9933
60UF4433
40BF9933
60BF4433
Pression 3/8 (9.53) 60,000 (4140) CL6600 CT6660 CX6666 60F6633 60UF6633 60BF6633
9/16 (14.3) 60,000 (4140) CL9900 CT9990 CX9999 60F9933 60UF9933 60BF9933
ext. Valeurs de
Tube Pression limiteur de Support disque
pouces (mm) psi (bar) crou Bague filete Bouchon Joint torique Bille dbit Double disque Cartouche de rupture
1/4 (6.35) 20,000 (1380) CGLX40 CCLX40 CPX40 CXO4400 CXB4400 CXK4402 - CXF4 CSX4600*
Moyenne 3/8
9/16
(9.53)
(14.3)
20,000 (1380)
20,000 (1380)
CGLX60
CGLX90
CCLX60
CCLX90
CPX60
CPX90
CXO6600
CXO9900
CXB6602
CXB9900
CXK6602
CXK9902
-
CLFX9900
CXF6
CXF9
CSX6600*
CSX9600*
Pression 3/4 (19.1) 20,000 (1380) CGLX120 CCLX120 CPX120 CXO12 CXB12 CXK1202 - - -
1 (25.4) 20,000 (1380) CGLX160 CCLX160 CPX160 CXO16 CXB16 CXK1602 - - -
1 (25.4) 43,000 (2964) CGLX160 CCLX160 43CPX160 43CXO16 43CXB16 - - - -
Haute 9/16
1/4
(14.3)
(6.35)
40,000 (2760)
60,000 (4140)
AGL90
AGL40
ACL90
ACL40
AP90
AP40
-
CXO4400
-
CB4401
-
CK4402
-
CLF4400
-
CF4
-
CS4600*
Pression 3/8 (9.53) 60,000 (4140) AGL60 ACL60 AP60 CXO6600 CB6601 CK6602 CLF6600 CF6 CS6600*
9/16 (14.3) 60,000 (4140) AGL90 ACL90 AP90 CXO9900 CB9901 CK9902 CLF9900 CF9 CS9600*
7
Tube
Autoclave Engineers propose une gamme complte de tubes en acier inox. austnitique
tir froid conu pour rpondre aux xigences des normes des vannes et raccords AE.
Le tube AE est fabriqu spcifiquement pour les applications haute pression ncessitant
la fois rsistance aux contraintes mcaniques et la corrosion. Le tube est fourni dans des
longueurs comprises entre 6,1m et 8,2m (20 et 27 pieds).
Contrles et essais
Le tube AE est contrl pour sassurer quil est exempt de soudure, dfauts, fissures et
autres imperfections, galement quil ne prsente pas de carburation ou de prcipatation
de carbone intergranulaire. Les diamtres intrieurs et extrieurs du tube sont soumis un
contrle spcifique et les dimensions comprises dans des tolrances serres pour garantir
un raccordement correct. Des chantillons de chaque lot sont tests pour confirmer les
caractristiques mcaniques. Des tests hydrostatiques sont galements mis en oeuvre sur une
base statistique et sont effectus la pression de travail du tube. Autoclave peut, sur demande,
effectuer les tests hydrostatiques sur 100% du lot.
Note: Ajouter -316 ou -314 la rfrence pour prciser la matire si elle nest pas indique.
crou
Rfrences crou
ext Bague fendue
Tube Moyenne Haute Zone de main- Bague fendue
pouces Pression Pression tien du tube
Corps de bague
(mm) (jusqu 1400 bars) (jusqu 4200 bars) par la bague Corps de
pour support vanne ou
Corps de
anti-vibration de raccord
vanne ou
1/4 (6.35) KCBGLX40-316MC KCGL40-316 de raccord
Zone de main-
tien du tube
3/8 (9.53) KCBGLX60-316MC KCGL60-316 Bague par la bague
filete* pour support
anti-vibration
9/16 (14.3) KCBGLX90-316MC KCGL90-316 Ligne de
contact Ligne de
dtanchit Bague
contact
filete*
3/4 (19.1) KCBGLX120-316MC - dtanchit
1 High Pressure to 43,000 psi (2964 bar) *Bague filete AE non inclus dans lensemble complet
9
Manomtres de qualit AE pour instrumentation
Matires et caractristiques
Prcision de 0,5% de la gamme de mesure.
Cadran plastique robuste - boitier robuste en alliage daluminium.
Panneau arrire clatable pour libration de pression en cas de dfaillance du tube de Bourdon.
Tube de Bourdon** en Acier Inox 316.
Mouvement de prcision en Acier Inox pour la prcision et la rsistance la corrosion atmosphrique.
Rglage de point zro situ sur la face du manomtre derrire le couvercle du cadran pour commodit
dutilisation
1/4" (F250C)
Note: Les manomtres peuvent Connection type filetage et cne
tre fournis avec des connexions Livr avec bague filete et crou
arrire; Ajouter la lettre B la
rfrence. Exemple: P-047B-CG. Etalonn en psi uniquement
Valeur
Rfrences Gamme mini. Diamtre
Catalogue de pression dintervalle du cadran
(psi) (psi) (pouces)
10
Produits spcialiss
Vannes boisseau sphrique
Les vannes boisseau sphrique AE sont conues pour
des applications de type ouvert-ferm haut dbit. Lorsque
la vanne est totalement ouverte la conception plein passage
minimise la perte de charge.
Les vannes boisseau sphrique AE sont
conomiques et faciles entretenir pour une
utilisation durable. Conue dune seule pice,
la tige-boisseau limine le risque de cisaillement
et diminue les effets de charge latrale qui se
produisent avec les pices conues en deux parties.
Les crous de sige peuvent tre resserrs pour
prolonger lutilisation. Le couple de fonctionnement
est faible pour diminiuer lusure et tendre la dure
de vie des pices. La vanne boisseau sphrique AE
est conue pour travailler des pressions allant jusqu
1380 bar 93C (20000 psi 200F) et des tempratures
jusqu 260C 345 bar (500F 5000 psi). Les vannes
boisseau sphrique AE sont disponibles en 2 voies et 3 voies
avec orifices de taille 4.7mm 12.7mm. Parmi les caractristiques:
construction en acier
Inox 316, siges PEEK, tige-boisseau en une seule pice et tancheit
faible friction.
11
Produits spcialiss
Blocs multi-voies collecteurs/distributeurs
Les blocs collecteurs/distributeurs permettent de rduire au minimum lespace et le temps ncessaires la
connexion dun circuit sous pression. Par ailleurs en rduisant le nombre des composants utiliss dans le sytme,
les blocs multi-voies limitent le nombre de points de fuite potentiels.
Autoclave Engineers peut concevoir et fabriquer des blocs multi-voies pour rpondre des besoins spcifiques
de disposition et de pression pour des installations spciales. Ces blocs multi-voies sont capables de tenir des
pressions allant du vide jusqu 4137 bar (60 000 psi),et sont disponibles en divers matriaux et tailles. Parmi
les types de raccordement pouvant tre intgrs, on retouve les types basses pressions, moyennes pressions
et hautes pressions Autoclave, ainsi que NPT, SAE, BSP, et autres. Les changements de taille de circuits du
systme et les montages en serie de tubes sous pressions peuvent tre effectus par un bloc multi-voies
spcialis. Ces blocs multi-voies peuvent tre utiliss en tout point dun circuit sous pression.
12
Outils
Clef dynamomtrique rglage micromtrique AE (P-1680)
P-1680 20 to 150 ft. lbs. (27 to 203 Nm)
91020 75 to 250 ft. lbs. (102 to 339 Nm)
Un serrage prcis des presse-toupe et des crous de connexion est essentiel. La cl peut tre ajuste dans
les plages indiques et est utilise avec les adapteurs interchangeables pour des six-pans de 1/2" 1-7/8".
Les rfrences des adapteurs se trouvent sur le tableau ci-dessous.
Rfrence
adapteur P-1681 P-1682 P-1683 P-9813 P-1685 P-1686 P-1687 P-9901 P-1688 P-1689 P-1690 P-6040 P-10076
de la clef
Caractristiques
Moteur de 1,5 CV , 220 VAC 50 Hz (115 VAC 60 Hz) dmarrage par condensateur.
Inversion inutile durant le filetage; l'ouverture rapide de l'outil prvient l'endommagement
ventuel des filets.
Disponibilit d'un outillage complet; prciser les tailles demandes.
La tte d'usinage de cne est dplace par un volant permettant une opration
facile et prcise.
Pompe huile et rservoir pour l'usinage de cne.
L'unit est monte sur chssis avec roulettes bloquables offrant mobilit et stabilit
de la machine.
En option desponibilit d'un rservoir chauffant
Estampille CE en standard sur les modles 220 VAC 50 Hz.
13
Outils
Support de lame
Outil fileter
Nota: Des kits complets doutils sont disponibles.
Consulter lusine. crou davance
dusinage
Logement de loutil
Bague crou
Taille du tube Rfrences des outils pour cnes et composants Rfrences des outils fileter et composants
Filire
ext. int. Outil avec Bague de Jeu de Outil Corps Bague de
pouces (mm) pouces (mm) Bague & Lames serrage 2 lames Complet doutil Rfrence Dimension* guidage
AE Moyenne Pression
1/4 (6.35) .109 (2.77) MCTM4 90248 101F-1577 402A 402 P-0214 1/4-28 1010-0343
3/8 (9.53) .203 (5.16) MCTM6 90250 101F-1601 402C 402 P-0215 3/8-24 1010-0344
9/16 (14.3) .312 (7.92) MCTM920 90251 1010-5218 402E 402 P-0216 9/16-18 1010-0345
9/16 (14.3) .359 (9.12) MCTM910 90251 101A-1897 402E 402 P-0216 9/16-18 1010-0345
1/4 (6.35) .083 (2.11) MCTH4 90248 101F-1577 402A 402 P-0214 1/4-28 1010-0343
AE Haute Pression
3/8 (9.53) .125 (3.18) MCTH6 90250 101F-1578 402C 402 P-0215 3/8-24 1010-0344
9/16 (14.3) .188 (4.78) MCTH960 90251 1010-0883 402E 402 P-0216 9/16-18 1010-0345
9/16 (14.3) .250 (6.35) MCTH940 90251 101C-7214 402E 402 P-0216 9/16-18 1010-0345
14
Calculs de dbits
Le Coefficient de debit (CV) dune vanne est le dbit deau, temprature ambiante, exprim en galon US par
minute circulant au travers de la vanne, compltement ouverte, pour une perte de charge de 1 psi. Le CV est un
coefficient de dimensionnement de la vanne qui permet de choisir la vanne ncessaire pour rpondre aux
contraintes de dbit dun systme fluide donn.
Les valeurs de CV indiques sur les pages de commande de la vanne representent le CV de cette vanne
lorquelle est totalement ouverte. En dterminant la capacit estime, cette valeur de CV devrait tre utilise
dans les fomules suivantes.
Formules de dbit
Liquides
V = CV P1 - P2
q Dbit, gal. U.S./mn. SGF
Gaz *=
Q = 42.2 CV (P1 - P2) (P1 + P2)
q Dbit, SCFH SG
=
Q = 963 CV (P1 - P2) (P1 + P2)
q Dbit, SCFH (temprature corrige)
SG TF
=
q Dbit, lb./hr. W = 3.22 CV (P1 - P2) (P1 + P2)/SG
Vapeur sature
=
q Dbit, lb./hr. W = 2.1 CV (P1 - P2) (P1 + P2)
15
Connexions
AE Moyenne Pression SFCX
Dimensions
Tube pouces (mm)
ext. Type de connexion 60
pouces (mm)
A B C D F H B
Filetage
1/4 SF250CX20 25/64 7/16 -20 .28 .50 .19 .109 A
Perage
(6.35) (7.11) (12.7) (4.83) (2.77) F
3/8 SF375CX20 33/64 9/16 -18 .38 .62 .31 .203 C
(9.53) (9.65) (15.7) (7.87) (5.16) D
AE Haute Pression FC
Dimensions
Tube pouces (mm)
ext. Type de connexion 60
pouces (mm) B
A B C D F H Filetage
A
1/4 F250C 33/64 9/16 -18 .38 .44 .17 .094 Perage
(6.35) (9.65) (11.2) (4.32) (2.39) F
Nota: Toutes les dimensions ne sont indiques qu titre indicatif et ne doivent pas tre considres comme des
dimensions relles dusinage.
*Pour les dimensions des sorties voir taille des orifices des vannes et raccords spcifiques.
Tous les filetages sont fabriqus une classe 2A ou 2B .
! AVERTISSMENT !
Le prsent document ( ainsi que tout renseignement provenant de Snap-tite Inc. , de ses filiales et distributeurs autoriss ) offrent le choix de produits
et/ou systmes destins permettre des utilisateurs techniquement comptents deffectuer des recherches supplmentaires. Il est important deffectuer
une analyse exhaustive de lapplication et dtudier les renseignements relatifs au produit ou systme dans le catalogue le plus rcent . En raison de la
grande varit de conditions dexploitation et dapplication de ces produits , lutilisateur est, suite ses analyses et essais raliss par ses soins, seul
responsable de son choix de produits et de systmes et de lassurance que toutes les conditions de fonctionnement , de scurit et davertissement ont t
satisfaites .
Les produits dcrits ici , y compris caractristiques, spcifications, dessins, disponibilit, prix, sans aucune limitation, sont succeptibles dtre modifis
par Snap-tite Inc.; et ses filiales tout moment sans avis pralable .
Industrial Estate
Whitemill - Wexford 8325 Hessinger Road
Republic of Ireland Erie, Pennsylvania 16509 USA
Ph: 353 53 914 1566 Fax: 353 53 914 1582 Ph: 814-860-5700 Fax: 814-860-5811
e-mail: ste_sales@snap-tite.com e-mail: ae_sales@snap-tite.com
www.snap-tite.com www.autoclaveengineers.com
08-0056BF-0709
Autoclave Engineers
Weltweit fhrend in
Autoclave Engineers hat ein weitergehendes,
fortschrittliches Druckhlsensystem-genannt
Hochdruckventilen-, QSS-Quick-Set-System-entwickelt.
Dieses 1/4 bis 3/4 Aussendurchmesser
2
Handventile
Autoclave Ventile sind fr das sichere und zuverlssige Arbeiten mit Drcken bis zu 10342 bar (150.000 psi) entwickelt.
Mehrere wichtige Eigenschaften ermglichen das zuverlssige arbeiten unter unterschiedlichen Bedingungen.
Betriebsdruck
*Nennwert Cv
Spindeltyp
Zoll (mm)
psi (bar)
(offen)
2-Wege Eckventil
2-Wege 2-Wege 3-Wegeventil, 3-Wegeventil, austauschbarer 3-Wegeventil
Durchgangsventil Eckventil 2 Druckeingnge 1 Druckeingng Sitz mit 2 Spindel
1/4 20,000 .31 Vee 20SM4071 20SM4072 20SM4073 20SM4074 20SM4872 20SM4075
(6.35) (1380) Reg 20SM4081 20SM4082 20SM4083 20SM4084 20SM4882 20SM4085
3/8 20,000 .75 Vee 20SM6071 20SM6072 20SM6073 20SM6074 20SM6872 20SV6075
(9.53) (1380) Reg 20SM6081 20SM6082 20SM6083 20SM6084 20SM6882 20SM6085
9/16 20,000 1.30 Vee 20SM9071 20SM9072 20SM9073 20SM9074 20SM9872 20SM9075
(14.3) (1380) Reg 20SM9081 20SM9082 20SM9083 20SM9084 20SM9882 20SM9085
3/4 20,000 2.50 Vee 20SM12071 20SM12072 20SM12073 20SM12074 20SM12872 20SM12075
Mitteldruck (19.1)
1
(1380)
20,000 4.40
Reg
Vee
20SM12081 20SM12082 20SM12083 20SM12084
20SM16071 20SM16072 20SM16073 20SM16074
20SM12882
20SM16872
20SM12085
20SM16075
(25.4) (1380) Reg 20SM16081 20SM16082 20SM16083 20SM16084 20SM16882 20SM16085
9/16 10,000 1.75 Vee 10SM9071 10SM9072 10SM9073 10SM9074 10SM9872 10SM9075
(14.30) (690) Reg 10SM9081 10SM9082 10SM9083 10SM9084 10SM9882 10SM9085
3/4 10,000 2.80 Vee 10SM12071 10SM12072 10SM12073 10SM12074 10SM12872 10SM12075
(19.10) (690) Reg 10SM12081 10SM12082 10SM12083 10SM12084 10SM12882 10SM12085
1 10,000 5.20 Vee 10SM16071 10SM16072 10SM16073 10SM16074 10SM16872 10SM16075
(25.40) (690) Reg 10SM16081 10SM16082 10SM16083 10SM16084 10SM16882 10SM16085
1 30,000 2.60 Vee 30SC16071 30SC16072 30SC16073 30SC16074 30SC16872 30SC16075
(25.4) (2070) Reg 30SC16081 30SC16082 30SC16083 30SC16084 30SC16882 30SC16085
1/4 30,000 .12 Vee 30VM4071 30VM4072 30VM4073 30VM4074 30VM4872 30VM4075
(6.35) (2070) Reg 30VM4081 30VM4082 30VM4083 30VM4084 30VM4882 30VM4085
3/8 30,000 .23 Vee 30VM6071 30VM6072 30VM6073 30VM6074 30VM6872 30VM6075
(9.53) (2070) Reg 30VM6081 30VM6082 30VM6083 30VM6084 30VM6882 30VM6085
9/16 30,000 .33 Vee 30VM9071 30VM9072 30VM9073 30VM9074 30VM9872 30VM9075
Hochdruck (14.3)
9/16
(2070)
40,000 .28
Reg
Vee
30VM9081 30VM9082
40VM9071 40VM9072
30VM9083
40VM9073
30VM9084
40VM9074
30VM9882
40VM9872
30VM9085
40VM9075
(14.3) (2760) Reg 40VM9081 40VM9082 40VM9083 40VM9084 40VM9882 40VM9085
1/4 60,000 .08 Vee 60VM4071 60VM4072 60VM4073 60VM4074 60VM4872 60VM4075
(6.35) (4140) Reg 60VM4081 60VM4082 60VM4083 60VM4084 60VM4882 60VM4085
3/8 60,000 .09 Vee 60VM6071 60VM6072 60VM6073 60VM6074 60VM6872 60VM6075
(9.53) (4140) Reg 60VM6081 60VM6082 60VM6083 60VM6084 60VM6882 60VM6085
9/16 60,000 .14 Vee 60VM9071 60VM9072 60VM9073 60VM9074 60VM9872 60VM9075
(14.3) (4140) Reg 60VM9081 60VM9082 60VM9083 60VM9084 60VM9882 60VM9085
*CV Werte gelten fr 2-Wege Durchgangsventile. Fr 2-Wege Eckventile CV plus 50%. Bitten beachten: SM Serie ersetzt 20SC Serie.
3
Pneumatisch bettigte Ventile (fr AE handbettigte Ventile)
Drei Grssen pneumatisch bettigter Ventile (Mittel-, Hoch- und Hchstdruck) stehen zur Auswahl fr fernbettigte Auf-Zu
Bedienung oder automatische Bedienung von Autoclave Mittel- oder Hochdruckventilen. Die pneumatischen AE-Ventile sind
in zwei Schaltvorrichtungen erhltlich: normal offen, mit Druckluft schliessend (air-to-open) und normal geschlossen, mit
Druckluft ffnend (air-to-close).
Bestell-Beispiele (Um eine sichere Auswahl zu treffen, setzen Sie sich bitte mit unserem Werk in Verbindung)
Um ein Ventil mit einer pneumatischen Bedienung zu bestellen, whlen Sie Nennleistung, und Ventiltyp aus der
untenstehenden Tabelle. Fgen Sie Bestellzusatz zur Katalognummer des AE-Ventils hinzu. Beispiele: 2-Wege-
Durchgangsventil, 30VM, Auf/Zu-Spindel, 9/16 (14,3mm), Mitteldruck, mit Druckluft ffnend: 30VM9071-C1S fr ein
Pneumatisch bettiges Joch (Yoke) Ventil mit Kolbenantrieb oder 30VM9071-CM fr ein pneumatisch bettigtes integrales
Ventil mit Membranantrieb.
4
Die untenstehende Tabelle erlaubt eine schnelle Selektion entprechender Bettgungsvorrichtungen basierend auf
Ventilausfhrung und Grsse, maximaler Systemarbeitsdruck und maximalem entsprechendem Pneumatikdruck.
Beispiel: Der Systemsarbeitsdruck betrgt 1723 bar (25,000 psi) und der verfgbare Pneumatikdruck 4,1 bar (60
psi) und ein normal offen (mit Druckluft schliessend) Ventil wird verlangt: ein 30VM oder 60VM Hchstdruckventil
kann Eingesetzt werden.
5
Kupplungen
Die hier erwhnten Kupplungen sind fr die Verbindungen aller Kombinationen von Autoclave Standardrohren mit
Innengewinde (female-to-female). Weitere Ausfhrungen stehen auf Anfrage zur Verfgung.
Bestellbeispiele: A B Verbindung
Verbindung AE Mitteldruck AE Hochdruck
1. Nennweite in Tabelle A
lokalisieren Rohrab- Anschluss- Druck 1/4 3/8 9/16 3/4 1 1 1/4 3/8 9/16 9/16
messung variante psi*(bar) (6.35) (9.53) (14.3) (19.1) (25.4) (25.4) (6.35) (9.53) (14.3) (14.3)
2. Nennweite in Tabelle B in.(mm) SF250CX SF375CX SF562CX SF750CX SF1000CX F1000C43 F250C F375C F562C F562C40
entsprechend zuordnen
1/4 SF250CX 20,000 20FX 20F 20F 20F 20F 20F 20F 20F 20F
3. Die entsprechende Katalognummer
(6.35) (1380) 4466 4666 4966 41266 41666 41663 4463 4663 4963
finden Sie im Schnittpunkt der AE Mitteldruck
3/8 SF375CX 20,000 20FX 20F 20F 20F 20F 20F 20F 20F
beiden Tabellen. (9.53) (1380) 6666 6966 61266 61666 61663 6463 6663 6963
Aussen-/Inngewinde Adapter
Aussen-/Inngewindeadapter erlauben eine Verbindung zu anderen Nennweiten und/oder Anschlussvarianten.
Bei der Selektion eines Adapters fr zwei unterschiedliche Nennweiten, sollte die grssere Verbindung auf der Seite des
Aussengewindes liegen, zur Maximierung der mechanischen Kraft des Adapters.
1/4(6.35) 3/8(9.53) 9/16(14.3) 3/4(19.1) 1(25.4) 1(25.4) 1/4(6.35) 3/8(9.53) 9/16(14.3) 9/16 (14.3)
Spalte lokalisieren SF250CX SF375CX SF562CX SF750CX SF1000CX F1000C43 F250C F375C F562C F562C40
2. Entsprechendes Innengewinde Aussenge-
Passend Arbeits-
zum druck 20,000 20,000 20,000 20,000 20,000 43,000 60,000 60,000 60,000 40,000
winde
entsprechend zuordnen t
Innenge-
winde
psi*
(bar)
(1380) (1380) (1380) (1380) (1380) (2964) (4140) (4140) (4140) (2758)
3. Die entsprechende Katalognummer 1/4 SF250CX 20,000 20M46K6 20M49K6 20M412K6 20M416K6 20M44K3 20M46K3 20M49K3
finden Sie im Schnittpunkt der (6.35) (1380)
beiden Tabellen. 3/8 SF375CX 20,000 20M64K6 20M69K6 20M612K6 20M616K6 20M64K3 20M66K3 20M69K3
AE Mitteldruck
(9.53) (1380)
9/16 SF562CX 20,000 20M94K6 20M96K6 20M912K6 20M916K6 20M94K3 20M96K3 20M99K3
Andere Adapter (14.3) (1380)
AE liefert auf Wunsch viele andere 3/4 SF750CX 20,000 20M124K6 20M126K6 20M129K6 20M1216K6 20M124K3 20M126K3 20M129K3 20M129K40
(19.1) (1380)
Ausfhrungen von Adaptern,Einschliesslich
AE UniVersa-Lok gesenkgeschmiedete 1 SF1000CX 20,000 20M164K6 20M166K6 20M169K6 20M1612K6 20M1616K6 20M164K3 20M166K3 20M169K3
(25.4) (1380)
Verbindungen, Einschweissverschraubung
1 F1000C43 43,000 43M164B3 43M166B3 43M169B3 43M169B40
zum Rohraussen- bzw. nominalem Rohr- (25.4) (2964)
durchmesser, Aussen-/Inndurchmesser.
1/4 F250C 60,000 20M44B6 20M46B6 20M49B6 20M412B6 43M416B6 60M46B3 60M49B3
AE Hochdruck
(6.35) (4140)
Werkstoffe 3/8 F375C 60,000 20M64B6 20M66B6 20M69B6 20M612B6 20M616B6 43M616B6 60M64B3 60M69B3
Alle AE Adapter sind Przsionsteile aus (9.53) (4140)
kaltgeschmiedetem Edelstahl Typ 316. 9/16 F562C 60,000 20M94B6 20M96B6 20M99B6 20M912B6 20M916B6 43M916B6 60M94B3 60M96B3
Weitere Werkstoffe auf Anfrage. (14.3) (4140)
9/16 F562C40 40,000 20M912G6
(14.3) (2758)
*Nennleistung - Die Druckleistung der AE Kupplungen ist auf den niedrigsten Druck der Vergindung ausgelegt!
6
Fittinge, Komponenten & Zubehr
Anschluss-Typ Betriebsdruck Anschlussausfhrungen
in. (mm) psi (bar)
Dichtkonus und Gewindeausfhrung
fr hchsten und wiederholten Einsatz,
Mitteldruck 1/4 to 1
(6.35 to 25.4)
to 20,000
(1380)
einschliesslich Druckschraube und
Sttzring. Anti-Vibrationsdruckschrauben
lieferbar.
Berstscheiben-
Anschluss-Komponenten Rckschlagventile Leitungsfilter halterung
Rohraussen-
durchmesser Arbeitsdruck Kugel-Type
Doppelfilter- Tassen- Berstscheiben-
in. (mm) psi (bar) Dichtschraube Druckring Stopfen O-Ring Kugel
Durchflussber-
schuss scheiben Filterelement sicherung
1/4 (6.35) 20,000 (1380) CGLX40 CCLX40 CPX40 CXO4400 CXB4400 CXK4402 - CXF4 CSX4600*
3/8 (9.53) 20,000 (1380) CGLX60 CCLX60 CPX60 CXO6600 CXB6602 CXK6602 - CXF6 CSX6600*
Mitteldruck 9/16 (14.3) 20,000 (1380) CGLX90 CCLX90 CPX90 CXO9900 CXB9900 CXK9902 CLFX9900 CXF9 CSX9600*
3/4 (19.1) 20,000 (1380) CGLX120 CCLX120 CPX120 CXO12 CXB12 CXK1202 - - -
1 (25.4) 20,000 (1380) CGLX160 CCLX160 CPX160 CXO16 CXB16 CXK1602 - CXF16 -
1 (25.4) 43,000 (2964) CGLX160 CCLX160 43CP160 43CO16 43CB16 - - - -
9/16 (14.3) 40,000 (2760) AGL90 ACL90 AP90 - - - - - -
Hochdruck 1/4 (6.35) 60,000 (4140) AGL40 ACL40 AP40 CKO4400 CB4401 CK4402 CLF4400 CF4 CS4600*
3/8 (9.53) 60,000 (4140) AGL60 ACL60 AP60 CKO6600 CB6601 CK6602 CLF6600 CF6 CS6600*
9/16 (14.3) 60,000 (4140) AGL90 ACL90 AP90 CKO9900 CB9901 CK9902 CLF9900 CF9 CS9600*
7
Hochdruckrohre
Autoclave Engineers bieten eine komplette Auswahl an austenitisch,
kaltgezogenen Edelstahlrohren nach strengsten AE-Vorschriften fr
Ventile und Fittinge an. AE Rohre sind speziell fr Hchstdruckanwen-
dungen betreffend Festigkeit und Korrosionsbestndigkeit hergestellt.
Die Herstellungslngen liegen zwischen 6,1 m und 8,2 m (20 und 27 feet).
Sonderlngen
Zustzlich zu den in der untenstehenden Tabelle
aufgefhrten Lngen sind Sonderlngen auf Anfrage
lieferbar.
Material
Edelstahl Typ 316, falls nicht anderweitig spezifiert.
Abmessung in.(mm)
Katalog-Nummer
Betriebsdruck
bei 100F (38C) 2.75 3 4 6 8 10 12
Aussendurch- Innendurch- psi (bar)
Anschlusstyp messer messer Lnge Lnge Lnge Lnge Lnge Lnge Lnge
SF250CX 1/4 (6.35) .109 (2.77) 20,000 (1380) CNX4402 CNX4403 CNX4404 CNX4406 CNX4408 CNX44010 CNX44012
SF375CX 3/8 (9.53) .203 (5.16) 20,000 (1380) CNX6603 CNX6604 CNX6606 CNX6608 CNX66010 CNX66012
SF562CX 9/16 (14.3) .312 (7.92) 20,000 (1380) CNX9904 CNX9906 CNX9908 CNX99010 CNX99012
SF562CX 9/16 (14.3) .359 (9.12) 15,000 (1034) CNLX9904 CNLX9906 CNLX9908 CNLX99010 CNLX99012
SF750CX 3/4 (19.1) .438 (11.1) 20,000 (1380) CNX1204 CNX1206 CNX1208 CNX12010 CNX12012
SF750CX 3/4 (19.1) .515 (13.1) 15,000 (1034) CNLX1204 CNLX1206 CNLX1208 CNLX12010 CNLX12012
SF1000CX 1 (25.4) .562 (14.3) 20,000 (1380) CNX1606 CNX1608 CNX16010 CNX16012
SF1000CX 1 (25.4) .688 (17.5) 15,000 (1034) CNLX1606 CNLX1608 CNLX16010 CNLX16012
F250C 1/4 (6.35) .083 (2.11) 60,000 (4140) CN4402 CN4403 CN4404 CN4406 CN4408 CN44010 CN44012
F375C 3/8 (9.53) .125 (3.18) 60,000 (4140) CN6603 CN6604 CN6606 CN6608 CN66010 CN66012
F562C 9/16 (14.3) .187 (4.78) 60,000 (4140) CN9904 CN9906 CN9908 CN99010 CN99012
F562C40 9/16 (14.3) .250 (6.35) 40,000 (2760) 40CN9904-316 40CN9906-316 40CN9908-316 40CN99010-316 40CN99012-316
F1000C43 1 (25.4) .438 (11.1) 43,000 (2964) 43CN1606-304 43CN1608-304 43CN16010-304 43CN16012-304
Bemerkung: Bitte Katalognummer mit Materialnummer -316 oder -304 ergnzen, falls nicht angegeben.
Vibrationssichere Rohranschlsse
Vibrationen und/oder Erschtterungen knnen die Arbeitsweise in Rohrsystemen beintrchtigen. Aus diesem
Grund bietet Autoclave Engineers komplett mit AE Hochdruckverbindungen austauschbare -
vibrationssichere Rohranschlsse.
Druckring*
9/16 (14.3) KCBGLX90-316MC KCGL90-316 Dichtung
Dichtung
3/4 (19.1) KCBGLX120-316MC -
9
AE Manometer
Werkstoff/Eigenschaften
Genauigkeit +/- 0.5%
Kunststoff-Einstellscheibe/Vorderseite Aluminiumguss
berdruck-Entlastungsventil
Werkstoff 316 Edelstahl Rohrverbindung
Przisionsedelstahlfhrung fr hohe Passgenauigkeit und Witterungsbestndigkeit
Nadel-Nullinieneinstellung
Qualitts-Manometer
Bndige Panel-Befestigung austauschbare Anzeigenscheibe
zur Installation auf jedem Qualitts-Manometer. Dies wird gesondert berechnet, falls
der Auftrag mit dem Zusatz PM gekennzeichnet ist.
Optional elektrische Kontaktanzeige-lieferbar fr alle Qualitts-
Manometer, justierbar fr niedrige und hohe elektrische Kontakte.
** Manometer aus Inconel 718 fr Bourdon-Rohre von 0-80.000 psi (0-5116 bar) und 0-50.000 psi (0-3447 bar).
Manometer aus K Monel fr Bourdon-Rohre von 0-30.000 psi (0-2068 bar).
P-0713 4-1/2
P-0714 6
10
Sonderprodukte
Kugelventile
AE Kugelventile sind fr Auf-Zu und Schnellfluss-
applikationen konstruiert. In der Offen-Stellung (nicht
absperrend) werden Druckverluste minimiert.
AE Kugelventile sind konomisch, praktisch wartungsfrei
und garantieren eine lange Lebensdauer. Einteilige
Ventilspindel, zapfengelagert, verhindert
Scherbruch und reduziert den Einfluss von
Seitenkrften,wie sie bei einer zweiteiligen
Spindel auftreten knnen. Ein niedriges
Drehmoment verhindert Verschleiss und
verlngert die Lebensdauer.
Anschlussgrsse
und Typ Druckleistung
(inches) PSIG bei 100F (bar bei 38C)
11
Sonderprodukte
Verteilerblock
Spezielle Verteilerblcke minimieren den Platzbedarf, reduzieren Installationszeit. Zustzlich werden bei der
Installation von weniger Komponenten evtl. Leckagen reduziert.
Autoclave Engineers konstruiert und fertigt Hochdruckventile fr spezielle Applikationen und Betriebsdrcke.
Die Verteiler sind fr Druckanwendungen von Vakuum bis 60.000 psi (4137 bar) und sind in verschiedenen
Werkstoffen und Abmessungen und Anschlussvarianten wie z.B. NPT, SAE, BSP und weiteren, lieferbar.
12
Werkzeuge
AE Mikrometer Drehmomentschlssel
P-1680 20 to 150 ft. lbs. (27 to 203 Nm)
91020 75 to 250 ft. lbs. (102 to 339 Nm)
Przises Festziehen aller AE Packungsschrauben und Rohrmuttern ist unbedingt erforderlich.
Der Drehmomentschlssel kann auf die untenstehenden Schlsselweiten engestellt werden und
mit austauschbaren Schlssel-Adaptern fr Muttern von 1/2 bis 1-7/8 verwendet werden.Teile-/
Bestellnummer: siehe Tabelle.
Packungsschraub-
oder Rohrmutter- 1/2 9/16 5/8 3/4 13/16 7/8 15/16 1 1-1/16 1-3/16 1-3/8 1-1/2 1-7/8
Schlsselweite (12.7) (14.3) (15.9) (19.05) (20.6) (22.2) (23.8) (25.4) (27) (30.2) (34.9) (38.1) (47.6)
in. (mm)
Teile-Nr. Drehmo- P-1681 P-1682 P-1683 P-9813 P-1685 P-1686 P-1687 P-9901 P-1688 P-1689 P-1690 P-6040 P-10076
ment-schlssel-
Adapter
Hydraulischer Rohrbieger
AE Biegewerkzeuge ermglichen ein schnelles,
genaues und einfaches Biegen von dickwandigen
Hochdruckrohren. Der Rohrbieger wird komplett
mit Pumpe, Zylinder, Rahmen und Biegebacken
im tragbaren Koffer geliefert. (Bestell-Nr.: HTB)
Pneumatisch bettigte Pumpe ist optional
lieferbar. (Bestell-Nr.: HTB-A)
Merkmale
1/2 PS Motor, 220 VAC, 50 Hz (115 VAC, 60 Hz) Volt Kondensatror Start.
Kein Rcklauf erforderlich beim Gewindeschneiden; aufspringende Schneideisen verhindern
Beschdigung des Gewindes.
Kompletter Werkzeugsatz lieferbar, bitte Werkzeuggrssen spezifizieren.
Konusschneidkopft mit Federwalze fr przise Beschickung.
Komplett mit lpumpe und Behlter.
Die Einheit ist komplett auf einem Gestall mit feststellbaren Laufrollen montiert.
Lieferbar optional mit Tankheizung
CE-Kennzeichen auf 220 VAC, 50 Hz Modelle.
13
Werkzeuge
Rohrendbearbeitungswerkzeuge
Autoclave Engineers fertigt ein manulles Konusschneidwerkzeug fr eine optimale Konus-Performance fr Rohre
bis 14.3 mm (9/16 Aussendurchmesser. Dieses Przisions-und Qualtitswerkzeug kann an Ort und Stelle zum
Bearbeiten von AE Mittel- und Hochdruckrohren eingesetzt werden.
Austauschbare Muttern fr jede Rohrgrsse gewhrleisten eine exakte Zentrierung der Rohre. Die Schneide-
zufhrung erlaubt es dem Bediener die Einschnitt-tiefe genau zu kontrollieren. Der Einsatz der austauschbaren,
rechtwinkeligen Schneidebltter gewhrleisten einen genaueren und schnelleren Schneidevorgang. Das Gewin-
deschneidwerkzeug kann fr alle Rohraussendurchmesser bis 14,3 mm (9/16) benutzt werden. Hierzu ist es
lediglich notwendig, das Schneideisen und die Fhrungsbuchse im Werkzeug auszutauschen.
Bemerkung: Kompletter Werzeugsatz lieferbar.
Bitte mit unserem Werk in Verbindung setzen.
Konusschneidwerkzeug
Gewindeschneidewerkzeug
Schneidlager
Spannmutter
Werkzeugkrper
(Gehase)
Mutter
1/4 (6.35) .109 (2.77) MCTM4 90248 101F-1577 402A 402 P-0214 1/4-28 1010-0343
AE Mitteldruck
3/8 (9.53) .203 (5.16) MCTM6 90250 101F-1601 402C 402 P-0215 3/8-24 1010-0344
9/16 (14.3) .312 (7.92) MCTM920 90251 1010-5218 402E 402 P-0216 9/16-18 1010-0345
9/16 (14.3) .359 (9.12) MCTM910 90251 101A-1897 402E 402 P-0216 9/16-18 1010-0345
1/4 (6.35) .083 (2.11) MCTH4 90248 101F-3939 402A 402 P-0214 1/4-28 1010-0343
AE Hochdruck
3/8 (9.53) .125 (3.18) MCTH6 90250 101F-1578 402C 402 P-0215 3/8-24 1010-0344
9/16 (14.3) .188 (4.78) MCTH960 90251 1010-0883 402E 402 P-0216 9/16-18 1010-0345
9/16 (14.3) .250 (6.35) MCTH940 90251 101C-7214 402E 402 P-0216 9/16-18 1010-0345
Empfohlenes l: P-8784
*Alle Gewinde der AE Mittel- und Hochdruckrohre entsprechen LH National Fine (Klasse 2).
Zur Beachtung: Rohrendbearbeitungswerkzeuge (Konus- und Gewindeschneiden) fr 3/4 (19,1 mm) und 1 (25,4 mm) Aussendurchmesser
fr Mittel- und Hochdruckrohre sind nicht lieferbar.
Fr diese Abmessungen ist das Modell AEGCTM-2 einzusetzen.
14
Durchflusswerte
Koeffizient des Durchflusses (Cv) fr Ventile ist das Wasservolumen in U.S. Gallonen pro Minute bei
Raumtemperatur und vllig geffneter Ventilspindel und einem Druckabfall von 1 psi. Cv gibt den
Abmessungsfaktur zur Auswahl des entsprechenden Ventils an.
Die CV -Werte - siehe Bestellbezeichungen Ventile - geben den vollen Durchfluss fr dieses Ventil an. Zur
Festlegung geschtzer Kapazitt sollte dieser CV -Wert in noch folgenden Formeln verwendet werden.
Durchflussformeln
Flssigkeiten
V = CV P1 - P2
q Durchfluss, U.S. gal./min. SGF
Gase *=
Q = 42.2 CV (P1 - P2) (P1 + P2)
q Durchfluss, SCFH SGF
=
Q = 963 CV (P1 - P2) (P1 + P2)
q Durchfluss, SCFH
(bei angepasster Temperatur) SGF TF
=
W = 3.22 CV (P1 - P2) (P1 + P2)/SG
q Durchfluss, lb./hr.
Nassdampf =
W = 2.1 CV (P1 - P2) (P1 + P2)
q Durchfluss, lb./hr.
=
Heissdampf W = 2.1 CV (P1 - P2) (P1 + P2)
q Durchfluss, lb./hr. (1 + 0.0007 TS)
W = Durchfluss, (lb./hr.)
Acethylen 0.897 Azeton 0.792
Luft 1.000 Alkohol 0.792 P1 = Eingangsdruck, (14.7 + psig)
Methan 0.553
Stickstoff 0.966 *Auswirkung der Fliesstemperatur bei Gas sind minimal bei Temperaturen zwishcen
30F und 150 F.
Sauerstoff 1.103 = Wenn Ausgangsdruck P2 geringer ist als 1/2 des Eigangsdruck P1:
Propangas 1.562 (P1 - P2) (P1 + P2): wird 0.87 P1.
Schwefeldioxid 2.208
Bemerkung: Die maximalen Cv-Werte in diesem Katalog sind festgelegt unter Zugrundele-
gung des Fluid Control Institute Berichtes FCI 58-2. Recommended Voluntary Standards
for Measurement Procedure for Determining Control Valve Flow Capacity, einschliesslich
Verfahrenstest, Konstruktion der Prfstde sowie Auswertung der Kenndaten.
15
Anschlussteile
AE Mitteldruck SFCX
Abmessungen
Rohr-Aussen- inches (mm) 60
durchmesser Anschlusstyp
in. (mm)
A B C D F H B
Gewinde
A
1/4 SF250CX20 25/64 7/16 -20 .28 .50 .19 .109 Bohrung
(6.35) (7.11) (12.7) (4.83) (2.77) F
AE Hochdruck FC
Abmessungen
Rohr-Aussen- inches (mm)
durchmesser Anschlusstyp
in. (mm) 60
A B C D F H
B
Gewinde
1/4 F250C 33/64 9/16 -18 .38 .44 .17 .094 A
Bohrung
(6.35) (9.65) (11.2) (4.32) (2.39) F
3/8 F375C 11/16 3/4 -16 .53 .62 .26 .125 5 C D
(9.53) (13.5) (15.7) (6.60) (3.18)
9/16 F562C 1-3/64 1-1/8 -12 .62 .75 .38 .188
(14.3) (15.7) (19.1) (9.65) (4.78) Abspritzloch
9/16 F562C40 1-3/64 1-1/8 -12 .62 .75 .38 .250
(14.3) (15.7) (19.1) (9.65) (6.35) H
Bemerkung: Alle Abmessungen sind freibleibend und dienen lediglich zur Orientierung.
*Fr ffnungsdiameter siehe Dsenabmessungen fr spezifische Ventile und Fittinge.
Alle Gewinde entsprechen den Klassen 2A oder 2B.
!ACHTUNG!
EINE FALSCHE ODER UNSACHGEMSSE AUSWAHL ODER ANWENDUNG DER HIERIN BESCHRIEBENEN PRODUKTE UND/ODER SYSTEME ODER DER DAMIT ZUSAMMENHNGENDEN ARTIKEL KANN ZU
UNFLLEN MIT TODESFOLGE, PERSONEN- ODER SACHSCHDEN FHREN.
Dieses Dokument und andere Informationen von Snap-tite, Inc., ihren Tochtergesellschaften und ihren Vertragshndlern beschreiben Produkt- und/oder Systemoptionen die von Anwendern mit
technischer Erfahrung eingehender zu prfen sind. Es ist wichtig, da Sie alle Aspekte des vorgesehenen Einsatzzwecks analysieren und die Produkt- oder Systeminformationen im aktuellen Produktkatalog
beachten. Aufgrund der Vielfalt der Einsatzbedingungen und Anwendungsbereiche fr diese Produkte und Systeme trgt der Benutzer die alleinige Verantwortung dafr da er auf der Grundlage der von ihm
durchgefhrten Analysen und Tests die geeigneten Produkte und Systeme auswhlt. Der Benutzer mu darber hinaus sicherstellen, da in Zusammenhang mit dem Einsatz alle relevanten Leistungsanforderun-
gen, Sicherheits- und Warnhinweise beachtet und eingehalten werden.
Die hierin beschriebenen Produkte, einschlielich ihrer Merkmale, Spezifikationen, Entwurfsmuster, Lieferbarkeit und Preise, knnen ohne besondere Ankndigung jederzeit von der Snap-tite, Inc. und/
oder ihren Tochtergesellschaften gendert werden.
Industrial Estate
Whitemill - Wexford 8325 Hessinger Road
Republic of Ireland Erie, Pennsylvania 16509 USA
Ph: 353 53 914 1566 Fax: 353 53 914 1582 Ph: 814-860-5700 Fax: 814-860-5811
e-mail: ste_sales@snap-tite.com e-mail: ae_sales@snap-tite.com
www.snap-tite.com www.autoclave.com
08-0055BG-0709
MANUAL VALVE SERIES
10V
10VRMM
MV/MVE
SW
10P/15P
10SM/20SM
30VM
30VRMM
60VM
60VRMM
100VM
Manual Valves
Operation and Maintenance Manual
Drawing #
4. While holding the valve body secure, use a torque wrench 2. Turn valve stem to full open position.
to tighten the packing gland to the value shown on the
3. Remove the packing gland locking device.
attached Installation Summary Chart. If a torque wrench
7. Remove the handle by loosening the set screw(s) located SECOND THRUST WASHER
in the larger hole of the handle (use a 5/32 hex wrench
for the 3" long handle, a 3/16 hex wrench for the 4" and
10-1/4" long handle) and remove it from the stem sleeve.
Unscrew the stem from the packing gland. Remove the
two nuts and thrust washer from the top of the stem STEM SLEEVE
11. Lubricate stem sleeve threads with Jet-Lube SS-301 or 4. Apply silicone grease or similar lubricant to sealing
similar lubricant. Thread the stem sleeve all the way into surfaces of seat. Apply Jet-Lube SS-301 or similar
the packing gland or the insert so that the stem is in lubricant to the seat retainer threads.
the full open position. While holding the housing in a vice,
5. Replace seat and seat retainer. Make certain that the seat
torque the packing gland to the value in the Installation
stays flat against the valve body. Tighten seat retainer to
Summary Chart and tighten the locknut. Apply silicone
the torque specified in the Installation Summary Chart.
grease or similar lubricant to the sealing surfaces of the
cone rings. Apply Jet-Lube SS-301 or similar lubricant
to the threads. Screw the housing into the valve body and
torque the housing to the value in the Installation Sum
HEX SOCKET
mary Chart. Replace the housing locking device. SET SCREW
12. Remove the handle from the stem. Unthread the stem PACKING GLAND
and packing washer installed in the body, screw in the LOWER PACKING
WASHER
packing gland and torque it to the value in the
STEM
Installation Summary Chart. Reinstall the packing gland
locking device.
BODY
SEAT
LOCKING DEVICE
NON-ROTATING
STEM
ADJUSTABLE PACKING
BELOW THREADS Figure 3: Valve with Replacement Seat
ANTI-EXTRUSION
BACK-UP RINGS
HIGH PRESSURE
CONED-AND-THREADED
CHOICE OF VEE OR CONNECTIONS
REGULATING STEM TIP
METAL-TO-METAL SEATING
PACKING GLAND
For service contact the Parker Autoclave Engineers Representa-
tive in your area or FAX Parker Autoclave Engineers Support
Services at 1-814-860-5703.
GROOVE PIN
UPPER STEM
LOCKING NUT
Notes:
A PACKING LOCATED OUT
OF TEMPERATURE
HT - (high temperature extended stuffing box option).
ANTI-EXTRUSION
BACK-UP RINGS
LT - (cryogenic extended stuffing box option).
EXTENDED HOUSING
1
SS30 is a registered trademark of Jet-Lube, Inc.
LOWER STEM
LOCKING DEVICE
Section 6.0
Installation Summary Chart
BODY
CONE SEAL
ANODIZED
ALUMINUM HANDLE
316 PACKING
GLAND
M3.5 x .7
SCREW
STEM LOCKING CLIP
SPACER
COLD WORKED
TYPE 316 SS ADJUSTABLE PACKING
BODY IN FIVE BELOW THREADS
PATTERNS
SPEEDBITE
"W" TUBE
SPEEDBITE
CONNECTION
"W" TUBE METAL-TO-METAL
CONNECTION VEE STEM TIP SEATING
Valve** Packing Gland Packing Gland Tube Gland Tube Gland Packing P/N Replaceable Replaceable Extended Extended Packing Gland Hex Packing Gland Hex and Lock
Series Hex Size Torque ~ Hex Size Torque Seat Retainer Seat Retainer Housing Housing Size Torque ~ Nut Sizes
TFE TG GY Hex Size Torque Hex Torque (w/ext. housing) (w/ext. housing)
in. (mm) ft-lbs (Nm) in. (mm) ft-lbs (Nm) (qty.) (qty.) (qty.) in. (mm) ft-lbs (Nm) in. (mm) ft-lbs (Nm) in. (mm) ft-lbs (Nm) in. (mm)
MV1/
MV2 1/2 (12.7) 12.5 (17.1) .393 (10.0) * - - P-0825 (1) - - - - - - - -
MVE1/
MVE2 1/2 (12.7) 12.5 (17.13) 3/8 (7.57) * - - P-0825 (1) - - - - - - - -
10V2/
SW2 1/2 (12.7) 12 (16.3) 1/2 (12.7) * - P-0492 (2) P-0825 (2) P-8926 (1) 1/2 (12.7) 10 (13.6) 5/8 (15.9) 10 (13.6) 1/2 (12.7) 12 (16.3) 7/32 (5.56)
10 V4 13/16 (20.6) 40 (54.2) 13/16 (20.6) * - P-0128 (1) P-0466 (1) P-8932 (1) 1 (25.4) 15 (20.4) 15/16 (23.8) 20 (27.2) 13/16 (20.6) 40 (54.4) 7/32 (5.56)
10 V6 13/16 (20.6) 40 (54.2) 13/16 (20.6) * - P-0128 (1) P-0466 (1) P-8932 (1) 1 (25.4) 10 (13.6) 15/16 (23.8) 15 (20.4) 13/16 (20.6) 40 (54.4) 7/32 (5.56)
10 V8 13/16 (20.6) 30 (40.7) 15/16 (23.8) * - P-0686 (1) P-1211 (1) P-8927 (1) 1 (25.4) 15 (20.4) 15/16 (23.8) 20 (27.2) 13/16 (20.6) 30 (47.6) 7/32 (5.56)
SW4 5/8 (15.9) 30 (40.7) 5/8 (15.9) * - P-0685 (2) P-1691 (2) P-8928 (1) 3/4 (19.1) 20 (27.2) 13/16 (20.6) 35 (47.6) 1-13/16 (30.2) 25 (34.0) 7.32 (5.56)
SW6 5/8 (15.9) 40 (54.2) 3/4 (19.1) * - P-0686 (2) P-1211 (2) P-8927 (1) 3/4 (19.1) 15 (20.4) 13/16 (20.6) 35 (47.6) 1-13/16 (30.2) 30 (40.8) 7/32 (5.56)
SW8 13/16 (20.6) 50 (67.8) 15/16 (23.8) * - P-0677 (2) P-0776 (2) P-8929 (1) 1 (25.4) 50 (68.0) 1 (25.4) 35 (47.6) 1-1/2 (38.1) 20 (27.2) 5/16 (7.94)
15P4 5/8 (15.9) 40 (54.2) - - P-0685 (2) P-1691 (2) P-8928 (1) - - - - - - 7/32 (5.56)
15P6 5/8 (15.9) 40 (54.2) - - P-0685 (2) P-1691 (2) P-8928 (1) - - - - - - 7/32 (5.56)
15P8 13/16 (20.6) 80 (108) - - P-0677 (2) P-0776 (2) P-8929 (1 set) - - - - - - 5/16 (7.94)
6
10P12 15/16 (23.8) + - - P-1758 (2) P-1759 (2) P-8930 (1 set) - - - - -
- 3/8 (9.53)
10P16 1-3/8 (34.9) 20 (27.2) - - P-1733 (2) P-1775 (4) P-8931 (1 set) - - - - - - 1/2 (12.7)
20SM4 5/8 (15.9) 40 (54.2) 1/2 (12.7) 20 (27.1) P-0685 (2) P-1691 (2) P-8928 (1) 3/4 (19.1) 35 (47.6) 13/16 (20.6) 35 (47.6) 1-13/16 (30.2) 25 (34.0) 7/32 (5.56)
20SM6 5/8 (15.9) 40 (54.2) 5/8 (15.9) 30 (40.7) P-0685 (2) P-1691 (2) P-8928 (1) 3/4 (19.1) 35 (47.6) 13/16 (20.6) 35 (47.6) 1-13/16 (30.2) 25 (34.0) 7/32 (5.56)
20SM9 13/16 (20.6) 80 (108) 15/16 (23.8) 55 (74.6) P-0677 (2) P-0776 (2) P-8929 (1 set) 1 (25.4) 125 (170) 1 (25.4) 100 (136) 1-1/2 (38.1) 100 (136) 5/16 (7.94)
20SM12 15/16 (23.8) + 1-3/16 (30.2) 90 (122) P-1758 (2) P-1759 (2) P-8930 (1 set) 1-3/8 (34.9) 140 (190) 1-3/8 (34.9) 120 (163.2) 1-3/4 (44.5) + 3/8 (9.53)
20SM16 1-3/8 (34.9) ++ 1-3/8 (34.9) 150 (203) P-1733 (2) P-1775 (4) P-8931 (1 set) 1-3/4 (44.5) 150 (203) 1-3/4 (44.5) 170 (231.2) 1-3/4 (44.5) ++ 1/2 (12.7)
Notes:
** Valve series and connection size in sixteenths of an inch are indicated.
+ Finger tight, then 3/4 turn with wrench (TFE only). 175 ft. - lbs. (238.9) N-m with TG packing. 120 ft.-lbs. (162.7) N-m with GY packing.
++ Finger tight, then 3/4 turn with wrench (TFE only). 325 ft. - lbs. (443.8) N-m with TG packing. 140 ft.-lbs. (189.8) N-m with GY packing.
~ Unless otherwise noted, torque values are for TFE packing. For TG packing add 10% and for GY packing add 25% to these values.
Erie, PA USA
* Torque wrench not required for AE Speedbite tube connections. Tighten gland until sleeve begins to grip tubing the 1-1/4 turns.
Valve** Packing Gland Packing Gland Tube Gland Tube Gland Packing P/N Replaceable Replaceable Extended Extended Packing Gland Hex Packing Gland Hex and Lock
Series Hex Size Torque ~ Hex Size Torque ^^ Seat Retainer Seat Retainer Housing Housing Size Torque ~ Nut Sizes
TFE TG GY Hex Size Torque Hex Torque (w/ext. housing) (w/ext. housing)
in. (mm) ft-lbs (Nm) in. (mm) ft-lbs (Nm) (qty.) (qty.) (qty.) in. (mm) ft-lbs (Nm) in. (mm) ft-lbs (Nm) in. (mm) ft-lbs (Nm) in. (mm)
30VM4 13/16 (20.6) 60 (81.3) 5/8 (15.9) 15 (20.3) P-0128 (1) P-0466 (1) P-8932 (1) 3/4 (19.1) 35 (47.6) 15/16 (23.8) 50 (67.8) 13/16 (20.6) 60 (81.3) 7/32 (5.56)
30VM6 13/16 (20.6) 60 (81.3) 13/16 (20.6) 25 (33.9) P-0128 (1) P-0466 (1) P-8932 (1) 1 (25.4) 35 (47.6) 15/16 (23.8) 50 (67.8) 13/16 (20.6) 60 (81.3) 7/32 (5.56)
30VM9 13/16 (20.6) 60 (81.3) 1-3/16 (30.2) 55 (74.6) P-0128 (1) P-0466 (1) P-8932 (1) 1-3/8 (34.9) 35 (47.6) 15/16 (23.8) 50 (67.8) 13/16 (20.6) 60 (81.3) 7/32 (5.56)
60VM4 13/16 (20.6) 60 (81.3) 5/8 (15.9) 25 (33.9) P-0864 P-8713 (2) P-8933 (1) 13/16 (20.6) 45 (61.2) 15/16 (23.8) 65 (88.1) 13/16 (20.6) 60 (81.3) 7.32 (5.56)
(1 set)
60VM6 13/16 (20.6) 60 (81.3) 13/16 (20.6) 50 (67.8) P-0864 P-8713 (2) P-8933 (1) 1 (25.4) 45 (61.2) 15/16 (23.8) 65 (88.1) 13/16 (20.6) 60 (81.3) 7/32 (5.56)
(1 set)
60VM9 13/16 (20.6) 60 (81.3) 1-3/16 (30.2) 110 (149.2) P-0864 P-8713 (2) P-8933 (1) 1-3/8 (34.9) 45 (61.2) 15/16 (23.8) 65 (88.1) 13/16 (20.6) 60 (81.3) 7/32 (5.56)
(1 set)
10VRMM2 5/8 (15.9) 20^ (27.1) 1/2 (12.7) * P-1654 (1) P-0467 (1) P-8934 (1) 5/8 (15.9) 25 (34.0) 5/8 (15.9) 15 (20.5) 5/8 (15.9) 20 (27.3) N/A
30VRMM4 13/16 (20.6) 50^ (67.8) 5/8 (15.9) 15 (20.3) P-1654 (1) P-0467 (1) P-8934 (1) 13/16 (20.6) 50 (67.8) 15/16 (23.8) 50 (67.8) 13/16 (20.6) 50 (67.8) N/A
60VRMM4 13/16 (20.6) 50^ (67.8) 5/8 (15.9) 25 (33.9) P-0864 (1) P-8713 (2) P-8933 (1) 15/16 (23.8) 35 (47.6) N/A N/A N/A N/A 7/32 (5.56)
(1 set)
60VRMM4 13/16 (20.6) 50^ (67.8) 13/16 (20.6) 50 (67.8) P-0864 (1) P-8713 (2) P-8933 (1) 1-3/8 (34.9) 35 (47.6) 15/16 (23.8) 55 (75.1) 13/16 (20.6) 75 (102.4) 7/32 (5.56)
(1 set)
7
100VM5 15/16 (23.8) 60 (81.3) 3/4 (19.1) 70 (95.0) 90368 (1) N/A 70 (95.2) NA N/A NA N/A 15/16 (7.94)
90369 (2)
100VM4 15/16 (23.8) 60 (81.3) 3/4 (19.1) 70 (95.0) 90368 (1) 1 (25.4) 70 (95.2) NA N/A NA N/A 15/16 (7.94)
90369 (2)
100VM6 15/16 (23.8) 60 (81.3) 3/4 (19.1) 70 (95.0) 90368 (1) 1 (25.4) 70 (95.2) NA N/A NA N/A 15/16 (7.94)
90369 (2)
Notes:
** Valve series and connection size in sixteenths of an inch are indicated.
^ Zero position of barrel or thimble must be changed.
^^ 60VM and 60VRMM packing is nylon (P-0829), leather (P-0803) and nylon (P-0829).
+ Finger tight, then 3/4 turn with wrench (TFE only). 175 ft. - lbs. (238.9) N-m with TG packing. 120 ft.-lbs. (162.7) N-m with GY packing.
++ Finger tight, then 3/4 turn with wrench (TFE only). 325 ft. - lbs. (443.8) N-m with TG packing. 140 ft.-lbs. (189.8) N-m with GY packing.
~ Unless otherwise noted, torque values are for TFE packing. For TG packing add 10% and for GY packing add 25% to these values.
* Torque wrench not required for AE Speedbite tube connections. Tighten gland until sleeve begins to grip tubing the 1-1/4 turns.
N/A Not Applicable
Erie, PA USA
Parker Autoclave Engineers
Instrumentation Products Division
This document and other information from Parker Hannifin Corporation, its subsidiaries and authorized distributors provide product or system options for further investigation by
users having technical expertise. The user, through its own analysis and testing, is solely responsible for making the final selection of the system and components and assuring that
all performance, endurance, maintenance, safety and warning requirements of the application are met. The user must analyze all aspects of the application, follow applicable
industry standards, and follow the information concerning the product in the current product catalog and in any other materials provided from Parker or its subsidiaries or
authorized distributors. To the extent that Parker or its subsidiaries or authorized distributors provide component or system options based upon data or specifications provided by
the user, the user is responsible for determining that such data and specifications are suitable and sufficient for all applications and reasonably foreseeable users of the components
or systems.
Offer of Sale
The items described in this document are available for sale by Parker Hannifin Corporation, its subsidiaries or its authorized distributors. Any sale contract entered by Parker will be
governed by the provisions stated in Parker's standard terms and conditions of sale (copy available upon request).
2013 Parker Hannifin Corporation | Autoclave Engineers is a registered trademark of the Parker Hannifin Corporation 02-0024ME January 2013
Industrial Estate
Whitemill - Wexford 8325 Hessinger Drive
Republic of Ireland Erie, Pennsylvania 16509 USA
Ph: 353 53 914 1566 Fax: 353 53 914 1582 Tl: +1 814-860-5700 Fax: +1 814-860-5811
e-mail: ste_sales@snap-tite.com e-mail: ae_sales@snap-tite.com
www.snap-tite.com www.autoclave.com