200 - 250 Kva Can-Model

1. A document discusses specifications for 5 electrical components labeled 1 through 5. 2. Each component lists standards of IEC 269-3 and IEC 269-2, voltages of 400V~ and 500V~, currents of 10A and less than 100KA, and manufacturer of Legrand. 3. The components are arranged from left to right and include labels, colors, and numbers associated with each.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
322 views1 page

200 - 250 Kva Can-Model

1. A document discusses specifications for 5 electrical components labeled 1 through 5. 2. Each component lists standards of IEC 269-3 and IEC 269-2, voltages of 400V~ and 500V~, currents of 10A and less than 100KA, and manufacturer of Legrand. 3. The components are arranged from left to right and include labels, colors, and numbers associated with each.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

6 5 4 3 2 1

Green
307 5

Red
Green Red
322 6 316 310 315 310
D D

6 6 322 322 302

6 322 315 316 301 307 302 302 303 5 5 ETH


300 300

C 1
C
MPR
1 MPR
5
IEC 269-3 IEC 269-3 IEC 269-3 IEC 269-3 IEC 269-3
308
400V ~ 400V ~ 400V ~ 400V ~ 400V ~
2
10 A 10 A 10 A 10 A 10 A
IEC 269-2 IEC 269-2 IEC 269-2 IEC 269-2 IEC 269-2
302 301
500V ~ I 500V ~ I 500V ~ I 500V ~ I 500V ~ I 308 21 J1 J2B J2A 2 5 W B
058 08

058 08

058 08

058 08

058 08
10 x 38 10 x 38 10 x 38 10 x 38 10 x 38
Icc < 100KA 0 Icc < 100KA 0 Icc < 100KA 0 Icc < 100KA 0 Icc < 100KA 0

legrand legrand legrand legrand legrand


3 8 11 30 6 3 24 54 55 25 34 22 41 37 31 32 42 23 10 W B

Panel
Connections for speed pot,
300 309 310 308 303 5
(if required) or when used 3
with Sync panel see note 1 6
CAN X1
ECM Loom X2
W
B

CAN
B B

Diagnostic
Connector
ATA
B
B
A
W
C E
309 5

MPSI Tool for Laptop - Links 6 & 3 DIAGNOSTICS: REFER TO MANUAL FOR DIAGNOSTIC TEST PROCEDURE AND FAULT FLASH CODES.
NOTE: LINK NOT REQUIRED IF ENGINE IS RUNNING
NOTE 1: SPEED BIASING 11(-) & 30(+)
NOTE 2: PUT WIRE 32 ON IDEAL JUNCTION WHEN USING SPEED BIASING

ECM TYPE 1 ECM TYPE 2 & 3


1500RPM - LINKS 37 & 32 ISOCHRONUS - 37 & 32
A 1800RPM - LINKS 37 & 31 MANUAL/DROOP LOADSHARE - 3, 8 & 11 Designed By: Approved By:
Ahmad Dahshi
Date: Ref: A
AUTO./ISOC. LOADSHARE - 37, 3, 30 & 11 Yasser Farhat 26/05/2014 6110/200-250

ECM TYPE 1 - 1500/1800RPM NON-LOADSHARING ISOCHRONUS Wiring Diagram of Relay Box DSE 6110 CAN
ECM TYPE 2 - 1500RPM MULTIFUNCTION
ECM TYPE 3 - 1800RPM MULTIFUNCTION FOR P200-250 (HEUI)
Jubaili Bros Engineering LTD
Client Name: Edition Sheet:
Available in ECM Loom : 5, 6, 12, 26, 27, 29, 36, 45, 46
END USER 01 3/3