PRODUCT DATA SHEET
SikaCoat
MULTIPURPOSE FLEXIBLE ACRYLIC BASED LIQUID APPLIED MEM-
BRANE
DESCRIPTION CHARACTERISTICS / ADVANTAGES
One component multipurpose flexible acrylic based li- Easy application.
quid applied membrane. It can be applied on exposed Excellent hiding power.
roof areas, parapet walls, external walls, etc. Thixotropic product.
High elasticity.
USES Excellent UV stability.
Impermeable.
Concrete sloped roofs should be > 3% (with mem- Crack bridging ability.
brane) Can be diluted with 10% water (we only recommend
Finishing for priming).
Sealing joints, laps and roofing screws on various kind Low consumption.
of roofs (roof tile, asbestos, zinc)
Parapet walls
External walls
PRODUCT INFORMATION
Chemical Base Aqueous Acrylic Dispersion
Packaging 20 kg, 4 kg pail
Colour Grey, Stone Grey, White, and Latte.
Shelf Life 12 months from date of production
Storage Conditions Stored properly in original, unopened and undamaged sealed packaging in
dry conditions at temperatures between +5 C and +30 C and protect from
direct sunlight.
Density at 30 C ~1.3 kg/L (EN ISO 2811-1)
TECHNICAL INFORMATION
Tensile Strength >2 N/mm2 (without membrane) (ASTM D412: 2006a (2013))
Elongation at Break > 400% (without membrane) (ASTM D412: 2006a (2013))
Adhesion in Peel >1.5 N/mm2 (without membrane) (ASTM D4541:2002)
Product Data Sheet
SikaCoat
September 2016, Version 01.01
020915104000000015
1/3
SYSTEM INFORMATION
System Structure Without Membrane System (DFT ~200 micron) :
First coat : 1 x SikaCoat
Second coat 1 x SikaCoat
APPLICATION INFORMATION
Ambient Air Temperature < 35 C
Substrate Temperature < 35 C
Drying Time > 3 hours depending upon ambient conditions
Applied Product Ready for Use Without membrane
First Coat : consumption : 0.3 kg/m2
Subsequent Coats : consumption : 0.3 kg/m2
APPLICATION INSTRUCTIONS LIMITATIONS
SUBSTRATE PREPARATION Ambient and surface temperatures must be below 35
C during application.
SURFACE PREPARATION Do not attempt application if rain is imminent.
Surface must be clean, sound and properly cured. Re- Avoid any ponding water on top of SikaCoat.
move all loose materials mechanically, preferably with Minimum slope for Roof application (with mem-
a wire brush. Iron and steel surfaces should be free of brane) should be 3 %.
rust. Allow minimum three weeks curing time for cementi-
tious substrates before apply SikaCoat.
APPLICATION
For Wall (Without Membrane): BASIS OF PRODUCT DATA
For porous substrate, apply first coat diluted with
10% water as primer layer. Allow enough drying time All technical data stated in this Product Data Sheet are
(>3 hours). based on laboratory tests. Actual measured data may
Apply SikaCoat in two coats (0.3 kg/m2/coat), by vary due to circumstances beyond our control.
brush or roller.
For Roof (With Membrane): LOCAL RESTRICTIONS
Apply a first coat (0.8 - 1 kg/m2) of SikaCoat by
brush or roller (diluted with 10% water if needed). Please note that as a result of specific local regula-
Embed the SikaCoat membrane into the second tions the declared data and recommended uses for
coat while it is still wet. Ensure that the membrane is this product may vary from country to country. Please
thoroughly embedded and smooth out all air pock- consult the local Product Data Sheet for the exact
ets and creases. Overlaps of adjacent membrane product data and uses.
must be a minimum of 50 mm.
Immediately apply a second coat (0.8 - 1 kg/m2) of ECOLOGY, HEALTH AND SAFETY
SikaCoat while the first coat is still wet, to fully sat-
For information and advice on the safe handling, stor-
urate the membrane from both sides.
age and disposal of chemical products, users shall refer
When touch-dry, apply a final top coat (~0.4 kg/m2)
to the most recent Safety Data Sheet (SDS) containing
to complete the application. Protect from rain until
physical, ecological, toxicological and other safety-re-
dry.
lated data.
CLEANING OF TOOLS
Remove uncured surface SikaCoat with water. Cured
material can only be removed mechanically.
Product Data Sheet
SikaCoat
September 2016, Version 01.01
020915104000000015
2/3
LEGAL NOTES
The information, and, in particular, the recommenda-
tions relating to the application and end-use of Sika
products, are given in good faith based on Sika's cur-
rent knowledge and experience of the products when
properly stored, handled and applied under normal
conditions in accordance with Sika's recommenda-
tions. In practice, the differences in materials, sub-
strates and actual site conditions are such that no war-
ranty in respect of merchantability or of fitness for a
particular purpose, nor any liability arising out of any
legal relationship whatsoever, can be inferred either
from this information, or from any written recom-
mendations, or from any other advice offered. The
user of the product must test the products suitability
for the intended application and purpose. Sika re-
serves the right to change the properties of its
products. The proprietary rights of third parties must
be observed. All orders are accepted subject to our
current terms of sale and delivery. Users must always
refer to the most recent issue of the local Product Data
Sheet for the product concerned, copies of which will
be supplied on request.
PT. Sika Indonesia
Jl. Raya Cibinong-Bekasi km.20.
Cileungsi, Bogor 16820 - Indonesia
Tel. +62 21 8230025
Fax. +62 21 8230026
Website: idn.sika.com
email: sikacare@id.sika.com