Section 2
Troubleshooting and Testing
Using Blink Code Diagnostics, Continued
NOTE                                                      1. Identify and record the blink code. Blink codes
Meritor WABCO recommends using the Meritor                   are identified in Columns 1 and 2.
WABCO test adaptor and a volt-ohm meter to                2. Measure the pins indicated. Pin locations to be
obtain these measurements.                                   tested are listed in Column 3.
Use the information in Table B, Meritor WABCO             3. Compare the measurement received against
C Version Hydraulic ABS Fault Codes, to identify a           the correct volt or ohm measurement listed in
fault, check for proper volt or ohm measurements             Column 4.
and repair the fault.
                                                          4. Follow the instructions listed in Column 5.
Table B  Meritor WABCO C Version Hydraulic ABS Blink Codes
 Ignition Key ON to Determine ABS
 Blink Code Fault                           Ignition Key OFF to Test System (except where noted)
       1                    2                        3                 4                      5
                                            Pin
                                            Locations        Correct Volt and
                                            To Be            Ohm Meter
 Fault Code     Problem Area                Tested           Readings             Action Required
 1-1            System OK
 2-0            Internal ECU fault                                              Replace ECU.
 2-1            Internal ECU fault                                              Replace ECU.
 2-2            Recirculation pump          11 and 27        0 volts              Check the recirculation
                operates continuously       30 and 27                             pump wiring, the pump
                (pump does not                                                    relay and the wiring
                switch off).                                                      connections. Repair or
                                                                                  replace as required.
 2-3            Recirculation pump does     9 and 11         12 volts DC          Check the recirculation
                not operate (pump does      27 and 30        Turn Ignition ON     pump wiring, the pump
                not switch on).                                                   relay and fuse and pump
                                                                                  connections. Repair or
                                                                                  replace as required.
 2-4            Recirculation pump          Link pins 9      Turn Ignition ON     Excessive current failure.
                motor locked.               and 11                                If pump does not run
                                                                                  when pins are linked,
                                                                                  replace modulator
                                                                                  assembly.
 2-5            Erratic wheel speed                                               Check for tire size
                                                                                  mismatch or tooth wheel
                                                                                  difference. Check sensor,
                                                                                  sensor cable and
                                                                                  connector for intermittent
                                                                                  contact. Make necessary
                                                                                  repairs.
                                                                                                      Page 7