WASTEWATER DIVISION
FLORIDA BIOLINE                                                                 THE WORLDS MOST ADVANCED
                                                                                 CONTINUOUS SELF-CLEANING, PRESSURE
DRIPLINE
                                                                                 COMPENSATING DRIPLINE SPECIFICALLY
                                                                                 DESIGNED FOR WASTEWATER
 CROSS SECTION
      OF FLORIDA
BIOLINE DRIPLINE
    Dripper inlets are
     positioned in the
 center of flow where
 water is the cleanest
                                                                                       APPLICATIONS
 PRODUCT ADVANTAGES                                                                     	 Typically installed following a treatment
  	 Pressure compensation - all drippers deliver equal flow, even on                      process
     sloped or rolling terrain.                                                         	 Can be used with domestic septic tank
  	 Unique flow path - Turbonet technology provides more control of                       effluent with proper design, filtration and
     water and a high resistance to clogging.                                              operation
  	 Continuous self-flushing dripper design - flushes debris, as it is                 	 Reuse applications including municipally
     detected - throughout operation, not just at the beginning or end of a                treated effluent designated for irrigation and
     cycle. Ensures uninterrupted dripper operation.                                       other disinfected and non-disinfected water
  	 Single hole dripper outlet from tubing:                                               sources.
      	- 	 Better protection against root intrusion
                                                                                        SPECIFICATIONS
      	- 	 Allows the dripline to be used in subsurface applications without
                                                                                        	 Dripper flow rates: 0.4, 0.6 or 0.9 GPH
           need for chemical protection
                                                                                        	 Dripper spacings: 12, 18 or 24 dripper
  	 Drippers capture water flow from the center of the tubing - ensures
                                                                                           spacings and blank tubing
     that only the cleanest flow enters the dripper.
                                                                                        	 Pressure compensation range: 7 to 58 psi
  	 Built-in physical root barrier - drippers are protected from root
     intrusion without the need for chemical protection. Water exits dripper            	 Maximum recommended system pressure:
     in one location while exiting the tubing in another.                                  58 psi
  	 Three dripper flow rates - provides the broadest range of flow rates               	 Tubing diameter: 0.66 OD, 0.56 ID
     available. Allows the designer to match the dripline to any soil or slope          	 Tubing color: Purple color indicates non-
     condition.                                                                            potable
  	 Florida Bioline tubing is completely wrapped in purple - easily                    	 Coil lengths: 500 or 1,000 (Blank tubing in
     identifying it for non-potable use, regardless of how the tubing is                   250)
     installed.                                                                         	 Recommended filtration: 120 mesh
  	 Can be used subsurface - Florida Bioline can be installed on-surface,              	 Bending radius: 7
     under cover or subsurface.                                                         	 UV resistant
  	 No special storage requirements - does not degrade if stored                       	 Tubing material: Linear low-density
     outdoors.                                                                             polyethylene
  	 Techfilter compatible - an optional level of protection, provides a
     limited lifetime warranty against root intrusion.                                 Additional spacing and pipe sizes available
                                                                                       by special order. Please contact Netafim USA
                                                                                       Customer Service for details.
FLORIDA BIOLINE DRIPLINE
 MAXIMUM LENGTH OF A SINGLE LATERAL WITH 3.0 fps FLUSH VELOCITY                                                                     MAXIMUM LENGTH OF A SINGLE LATERAL WITH 1.5 fps FLUSH VELOCITY
 ADDITIONAL FLOW OF 2.3 GPM REQUIRED PER LATERAL TO ACHIEVE 3 fps                                                                   ADDITIONAL FLOW OF 1.2 GPM REQUIRED PER LATERAL TO ACHIEVE 1.5 fps
                  DRIPPER SPACING                 12                             18                             24                                DRIPPER SPACING                12                             18                             24
DRIPPER FLOW RATE (GPH)              0.4 GPH 0.6 GPH 0.9 GPH        0.4 GPH 0.6 GPH 0.9 GPH          0.4 GPH 0.6 GPH 0.9 GPH        DRIPPER FLOW RATE (GPH)            0.4 GPH 0.6 GPH 0.9 GPH        0.4 GPH 0.6 GPH 0.9 GPH          0.4 GPH 0.6 GPH 0.9 GPH
                          15           102       94        84         136         127       113        161       151       137                               15          201       171       140        275         235       194        337       289       241
 INLET PRESSURE
                                                                                                                                    INLET PRESSURE
                          25           151       136       118        203         184       161        245       223       197                               25          266       222       179        366         308       251        453       383       313
                          35           193       171       146        260         232       200        315       283       245                               35          316       262       210        437         365       295        543       455       369
                          40           211       186       158        286         254       218        347       311       267                               40          337       280       223        469         391       313        583       487       393
                          45           228       200       169        310         274       233        377       335       287                               45          358       296       235        497         413       331        619       517       415
 Flow per 100 (GPM / GPH)            0.67/40   1.02/61   1.53/92   0.44/26.67   0.68/41   1.02/61    0.34/20   0.51/31   0.77/46   Flow per 100 (GPM / GPH)           0.67/40   1.02/61   1.53/92   0.44/26.67   0.68/41   1.02/61    0.34/20   0.51/31   0.77/46
  Lateral lengths are based on flows allowing for a 3 fps flushing/scouring velocity                                                 Lateral lengths are based on flows allowing for a 1.5 fps flushing/scouring velocity
 MAXIMUM LENGTH OF A SINGLE LATERAL WITH 2.5 fps FLUSH VELOCITY                                                                     MAXIMUM LENGTH OF A SINGLE LATERAL WITH 1.0 fps FLUSH VELOCITY
 ADDITIONAL FLOW OF 2.0 GPM REQUIRED PER LATERAL TO ACHIEVE 2.5 fps                                                                 ADDITIONAL FLOW OF 0.8 GPM REQUIRED PER LATERAL TO ACHIEVE 1.0 fps
                  DRIPPER SPACING                 12                             18                             24                                DRIPPER SPACING                12                             18                             24
DRIPPER FLOW RATE (GPH)              0.4 GPH 0.6 GPH 0.9 GPH        0.4 GPH 0.6 GPH 0.9 GPH          0.4 GPH 0.6 GPH 0.9 GPH        DRIPPER FLOW RATE (GPH)            0.4 GPH 0.6 GPH 0.9 GPH        0.4 GPH 0.6 GPH 0.9 GPH          0.4 GPH 0.6 GPH 0.9 GPH
                          15           128       115       100        172         155       136        205       187       165                               15          248       205       163        344         285       228        427       355       285
 INLET PRESSURE
                                                                                                                                    INLET PRESSURE
                          25           183       161       137        248         220       188        301       268       231                               25          315       258       203        440         361       286        549       453       359
                          35           228       198       166        310         272       229        379       333       283                               35          367       299       234        513         419       331        643       527       417
                          40           248       214       178        338         295       247        413       362       305                               40          389       316       248        545         445       350        683       559       441
                          45           266       229       190        364         316       263        447       389       327                               45          409       332       260        574         468       367        721       589       463
 Flow per 100 (GPM / GPH)            0.67/40   1.02/61   1.53/92   0.44/26.67   0.68/41   1.02/61    0.34/20   0.51/31   0.77/46   Flow per 100 (GPM / GPH)           0.67/40   1.02/61   1.53/92   0.44/26.67   0.68/41   1.02/61    0.34/20   0.51/31   0.77/46
  Lateral lengths are based on flows allowing for a 2.5 fps flushing/scouring velocity                                               Lateral lengths are based on flows allowing for a 1 fps flushing/scouring velocity
 MAXIMUM LENGTH OF A SINGLE LATERAL WITH 2.0 fps FLUSH VELOCITY                                                                     MAXIMUM LENGTH OF A SINGLE LATERAL WITH 0.5 fps FLUSH VELOCITY
 ADDITIONAL FLOW OF 1.6 GPM REQUIRED PER LATERAL TO ACHIEVE 2.0 fps                                                                 ADDITIONAL FLOW OF 0.4 GPM REQUIRED PER LATERAL TO ACHIEVE 0.5 fps
                  DRIPPER SPACING                 12                             18                             24                                DRIPPER SPACING                12                             18                             24
DRIPPER FLOW RATE (GPH)              0.4 GPH 0.6 GPH 0.9 GPH        0.4 GPH 0.6 GPH 0.9 GPH          0.4 GPH 0.6 GPH 0.9 GPH        DRIPPER FLOW RATE (GPH)            0.4 GPH 0.6 GPH 0.9 GPH        0.4 GPH 0.6 GPH 0.9 GPH          0.4 GPH 0.6 GPH 0.9 GPH
                          15           161       141       119        217         191       164        263       233       201                               15          301       242       188        422         341       265        531       429       335
 INLET PRESSURE
                                                                                                                                    INLET PRESSURE
                          25           221       190       157        302         261       218        369       321       270                               25          369       296       228        520         418       323        655       527       409
                          35           269       229       187        370         316       260        455       391       324                               35          421       337       260        595         476       368        749       603       467
                          40           290       246       200        399         340       278        493       421       347                               40          443       354       273        626         501       387        790       635       491
                          45           310       261       212        427         362       296        527       449       369                               45          464       371       285        656         524       404        829       665       513
 Flow per 100 (GPM / GPH)            0.67/40   1.02/61   1.53/92   0.44/26.67   0.68/41   1.02/61    0.34/20   0.51/31   0.77/46   Flow per 100 (GPM / GPH)           0.67/40   1.02/61   1.53/92   0.44/26.67   0.68/41   1.02/61    0.34/20   0.51/31   0.77/46
  Lateral lengths are based on flows allowing for a 2 fps flushing/scouring velocity                                                 Lateral lengths are based on flows allowing for a 0.5 fps flushing/scouring velocity
Netafim recommends flushing velocities capable of breaking free any accumulated bioslimes and debris in the piping network.
Notes: 	                 1.	   Refer to local regulations for information on flushing velocities that may be written into codes.
	                        2.	   Netafim does not endorse a specific flushing velocity.
	                        3.	   Flushing velocities should be determined based on regulations, quality of effluent, and type of flushing control.
	                        4.	   Using a flushing velocity less than 1 fps does not provide turbulent flow as defined by Reynolds Number.
	                        5.	   Higher flushing velocities provide more aggressive flushing.
                            EXPLODED VIEW OF FLORIDA BIOLINE DRIPPER                                                                        FLORIDA BIOLINE DRIPPER OPERATION
                                  Bottom View                                                   Top View                                    Florida Bioline drippers are pressure compensating
                  Large inlet filtration area
                                                                                                                                            - delivering the water uniformly into the soil for further
                     (bottom of dripper)                                                                      Dripper Outlet                treatment or for reuse by the landscape. These unique
                                                                                                              (top of dripper)              drippers allow the tubing to be installed on flat topography
                                                                                                                                            or steep slopes.
                                                                                                                                            Netafim drippers are continuously self-cleaning during
                                                                              Physical barrier separates where
                                                                              water leaves the dripper from                                 operation, not just at the beginning and end of a cycle. The
  Chemical-resistant                                                          where it leaves the tubing.                                   result is dependable, clog-free operation, year after year.
     molded silicon
         diaphragm
                                                                                                Drippers Top View
                                                                                             Top of dripper (turned over)
                    TurboNet wide
                       flow path
                         DRIPPER FLOW RATE VS. PRESSURE
                   1.0
                   0.9                         0.9 GPH                                                                 FLOW PER 100 FEET
                   0.8
                                                                                                                       DRIPPER        0.4 GPH DRIPPER        0.6 GPH DRIPPER     0.9 GPH DRIPPER
FLOW RATE (GPH)
                   0.7
                   0.6                                                    0.6 GPH
                                                                                                                       SPACING         GPH       GPM          GPH       GPM       GPH       GPM
                   0.5                                                                                                      12"        40.0         0.67      61.0      1.02      92.0       1.53
                   0.4                                                                   0.4 GPH
                                                                                                                            18        26.7         0.44      41.0      0.68      61.0       1.02
                   0.3
                   0.2                                                                                                      24        20.0         0.34      31.0      0.51      46.0       0.77
                   0.1
                     0
                             10           20             30          40             50             58
                                                   PRESSURE (psi)
                                   Between 0 and 7 psi, the dripper functions as a
                                   turbulent flow emitter, ensuring that the nominal
                                   design flow is not exceeded at system start-up.                                                FLORIDA BIOLINE ORDERING INFORMATION
                                                                                                                                  FLOW         DRIPPER        COIL          MODEL
                                                                                                                                  RATE         SPACING      LENGTH         NUMBER
                                                                                                                                                             1,000'    08WRAM.4-12
                                                                                                                                  0.4 GPH         12"
                                                                                                                                                              500'     08WRAM.4-12500
       SPECIFYING INFORMATION
                                                                                                                                                             1,000'    08WRAM.4-18
                                                                                                                                  0.4 GPH         18"
                                                         SAMPLE MODEL NUMBER                                                                                  500'     08WRAM.4-18500
                                                                             1      2    3
           A                                                                                                                                                 1,000'    08WRAM.4-24
                                                                                                                                  0.4 GPH         24"
                          Florida
                          Bioline = 08WRAM               08WRAM.6-24                                                                                          500'     08WRAM.4-24500
                         Dripline                             A                                                                                              1,000'    08WRAM.6-12
                                                                                                                                  0.6 GPH         12"
                                                                                                                                                              500'     08WRAM.6-12500
            1                                  2                     3
                      DRIPPER                      DRIPPER                    COIL                                                                           1,000'    08WRAM.6-18
                     FLOW RATE                     SPACING                  LENGTH
                                                                                                                                  0.6 GPH         18"
                                                                                                                                                              500'     08WRAM.6-18500
                     0.4 GPH = .4                  12 = 12                 500 = 500                                                                       1,000'    08WRAM.6-24
                     0.6 GPH = .6                  18 = 18               1,000 = LEAVE                                          0.6 GPH         24"
                                                                                                                                                              500'     08WRAM.6-24500
                     0.9 GPH = 1                   24 = 24                        BLANK
                                                                                                                                                             1,000'    08WRAM1-12
                                                                                                                                  0.9 GPH         12"
                                                                                                                                                              500'     08WRAM1-12500
             BLANK Tubing Model Number: 250 = 08WRAM-250
                                                                                                                                                             1,000'    08WRAM1-18
                                                                                                                                  0.9 GPH         18"
                                                                                                                                                              500'     08WRAM1-18500
                                                                                                                                                             1,000'    08WRAM1-24
                                                                                                                                  0.9 GPH         24"
                                                                                                                                                              500'     08WRAM1-24500
                                                                                                                                  Blank Tubing 17mm           250'     08WRAM-250
FLORIDA BIOLINE FITTINGS
FITTING APPLICATIONS
 	 Fits Florida Bioline Dripline
FITTING SPECIFICATIONS
 	 Barbed fittings for a secure fit
 	 Easy installation without glue or tools
 	 Allows for easy on-site inspection of proper fitting installation
        TLCOUP                               TLELL                             TLTEE                       TLCROS
     Insert Coupling                      Insert Elbow                       Insert Tee                  Insert Cross
        TL050MA                             TL075MA                          TL075FTEE                   TL2W075MA
     Male Adapter                     Male Adapter                    Combination Tee                2-Way Insert
                                                                         Ins x Ins x  FPT              MPT x Insert
                                         TLIAPVC-B                            TDBIT16.5
         TLIAPE-B               Insert Adapter with Grommet             Drill Bit for TLIAPVC
 Insert Adapter for 1 or          1 or larger PVC Pipe             Fitting (16.5mm or 21/32)
Larger PE (Requires 11mm
  or 7/16 drill or punch)
                                                                         FITTING DEFINITIONS
                                                                         FPT = Female Pipe Thread
                                                                         MPT = Male Pipe Thread
         TLFIG8                              TLS6                        Ins x Ins = Insert by Insert
    Figure 8 Line End                    6 Soil Staple
        TLSOV                                TLCV
     Shut-Off Valve                   Inline Check Valve
       Ins x Ins              Flow Range:           0.9 to 4.4 GPM
                                                                                                                          NETAFIM USA
                              Opening Pressure:     10.2 psi                                                             5470 E. Home Ave.
                              Closing Pressure:     5.8 psi                                                              Fresno, CA 93727
                               (13.4 Feet Column of Water)                                                                CS	 888 638 2346
                                                                                                                          www.netafimusa.com
                                                                                                                                               W064FL 10/16