Avaya             Configuration Note 88019  Version L (1/10)
Modular Messaging
                                                Ericsson MD-110
                                                                                                                                                           Message
                                                              Ericsson MD110                                                                              Application
                                                                                                                                                            Server
                                                                                                                Automated Attendant
                                                                                                                Multiple Return to Operator                Voice
                                                         TRUNK                                                                                             Boards
                                                                                         ELU
                                                                                                                                                           COM
                                                                CPU CABINET                 ICU                          RS232                              Port
                                                                                                                           Call ID
                                                                                                                     Message Waiting                   Supported
                                                                                                                                                    Supported    Software
                                                                                                                                                              Software
                                                                Minimum Release:
                                                                Refer to Section 3.1                                                                    Releases
                                                                                                                                                      see Section2.0,
                                                                                                                                                                  2.0 3.0
                                                1.0 METHOD OF INTEGRATION
                                                With RS232 integration, call information is transmitted over a digital RS232 link
   With RS232 integration, call                 between the PBX and the Avaya Message Application Server (MAS). Voice
information is transmitted over a               communications are provided over separate analog lines on the PBX that connect
  digital RS232 link between the                to the MAS. When an incoming call is received, it is accompanied by a digital
   PBX and the Avaya Message                    message from the PBX containing call information. The MAS then answers the
        Application Server                      call and plays the appropriate greeting. The RS232 link also handles on & off
                                                message waiting indication.
          MAS requirements                      2.0 AVAYA MESSAGE APPLICATION SERVER REQUIREMENTS
            1
                Release Note:                       Integration cables (PN 057-1580-000 & 003-1081-000)
     Should features of the integration not
 function optimally when integrated to a PBX         Dialogic D/41JCT-LS or D/120JCT-LS cards (4 and 12 port/cards)
      or MM that may be operating on an
   unsupported software release as defined           Releases 1: 1.1, 2.0, 3.x, 4.0, 5.x
  Section 2.0 and 3.1, customers will need to
      upgrade their PBX and/or MM to a
          supported software release.            3.0 PBX HARDWARE REQUIREMENTS
    PBX hardware requirements                       ELU24 or ELU29 channel, one per MAS port
                                                    ICU2 card ROF 137 5397-1
                                                Disclaimer: Configuration Notes are designed to be a general guide reflecting AVAYA Inc. experience configuring its systems. These
                                                notes cannot anticipate every configuration possibility given the inherent variations in all hardware and software products. Please
                                                understand that you may experience a problem not detailed in a Configuration Note. If so, please notify the Technical Service
                                                Organization at (800) 876-2835, and if appropriate we will include it in our next revision. AVAYA Inc. accepts no responsibility for
                                                errors or omissions contained herein
                                 ERICSSON MD-110 (RS-232)                                                                   2
                                     Minimum Firmware Level:
                                      -RYT/ROFU 131 0021/1 R1A P50
                                     Cables:
                                      - RJ11 four-wire telephone cord, one per MAS port
                                      - TSR 901-0043/1700 and TSR 902-0038/15000 (order with female
                                      DB25)
                                    The customer must provide the necessary hardware.
                                 3.1 PBX SOFTWARE REQUIREMENTS
  PBX software requirements         Minimum Software 1 (see pg 1): ASB50104, Release 1
                                     Software Patch number 12198
                                     Options:
                                    -ILP -DIR
                                    -MWP -IHAH
                                    -DIM -IHH
                                 4.0 SUPPORTED INTEGRATION FEATURES
Supported integration features   [9] Items are supported
                                 System Forward to Personal Greeting
                                      All Calls                                                [ ]
                                      Ring/no answer                                           [9]
                                      Busy                                                     [9]
                                      Busy/No Answer                                           [ ]
                                 Station Forward to Personal Greeting
                                       All Calls                                               [9]
                                       Ring/no answer                                          [9]
                                       Busy                                                    [9]
                                       Busy/No Answer                                          [ ]
                                 Auto Attendant                                                [9]
                                 Call Me                                                       [9]
                                 Direct Call                                                   [9]
                                 External Call ID (ANI)                                        [9]
                                 Find Me                                                       [ ]
                                 Internal Call ID                                              [9]
                                 Message Waiting                                               [9]
                                 Multiple Return to Operator                                   [9]
                                 Multiple Call Forward                                         [9]
                                 N+1                                                           [ ]
                                 Outcalling                                                    [9]
                                 The above information is provided by AVAYA Inc. as a guideline. See disclaimer on page 1
                                   ERICSSON MD-110 (RS-232)                                                                                 3
                                   5.0 CONFIGURING THE ERICSSON MD-110 TO INTEGRATE
                                       Use the ICFUP command to configure the ICU port.
Configuring the MD 110 data link
                                   ICUIND EQU                 RATE           DFMT          UPDPCN PARITY CCHECK                       TXC
                                     0     X                  9600            Y             YES   EVEN    YES                         YES
                                   Where X=ICU card slot number and Y=the number of digits in the extension
                                   number.
                                   Note: Verify these values with the MAS.
                                   Use the VMFUP command to configure the I/O data link to pass a four (4)
                                   digit port ID number.
                                   o                                                    ICUND               VMF               POFMT
                                                                     0                  EXTN2                4
                                   Install software patch number 12198 on Program Unit CMPS12 and ELP6.
   Create the analog lines
                                   5.1 CONFIGURING THE VOICE LINES
   connected to the MAS
                                       Configure the ELU24 channels as follows:
                                                CAT = 1
                                                TYPE = EL6
                                          Configure the Voice Mail channels for all Class of Service features.
                                          Configure the hunt group using the GHDAP command. Assign the hunt
                                          group pilot number and set queue to 0.
                                          Configure the call diversion (call forward) target as the hunt group pilot
                                          number using the CDIDP command. The subscriber can then control call
                                          diversion (forwarding) from their phone.
                                          Application system parameter 56 defines how the phones will
                                          transmit DTMF tones. Set to 15 will allow the digital sets to send
                                          DTMF tones always. Set to 9 will require the subscriber to press 9, or
                                          press ETE button, to activate tone sending. Avaya Inc. recommends
                                          setting this parameter to 15.
                                   Please refer to the Consideration section at the end of this document for
                                   special PBX programming considerations.
                                   The above information is provided by AVAYA Inc. as a guideline. See disclaimer on page 1
                          ERICSSON MD-110 (RS-232)                                                                   4
                          6.0 CONFIGURING THE MESSAGE APPLICATION SERVER
Configuring the Message
  Application Server             Configuring the MAS platform for proper PBX integration requires
                                 configuring several folders accessed within the Voice Mail System
                                 Configuration application.
                               Access the Voice Mail System Configuration application from the MAS
                                program group.
                               Access the Voice Mail Domain, and then select:
                                          PBXs  Ericsson MD-110
                               Access the General tab and set the following values:
                                          Go Off Hook when Port Disabled = Enable by checking the box
                                          Pause before Digits = 500
                                          Pause Interval for Comma in Dial String (ms) = 2000
                                          DTMF Inter-Digit Delay during Dialing (ms) = 80
                                          DTMF Length during Dialing = 800
                                          DTMF Length during Detection = 50
                               Access the Call Transfer tab and set the following values:
                                          Transfer Mode = Blind
                                          Transfer Prefix Code = &,XN
                                          Transfer Completion Code = Leave Blank
                                          Transfer Release Code when Busy = &&
                                          Transfer Release Code when No Answer = &&
                                          Transfer Release Code when Reject = &,,
                                          Flash Time Interval (ms) = 100
                                          Enable Call Progress = Enable by checking the box
                                          Start Delay for Call Progress (ms) = 1000
                               Access the Hangup Detection tab and set the following values:
                                          Maximum Continuous Tone before Hanging Up (ms) = 6000
                                          Hangup String = Leave Blank
                                          Hangup String Timeout (ms) = 0
                                          Minimum Duration For Drop in Loop Current = 300
                                          Maximum Silence before Hanging Up (ms) = 6000
                               Return to the Voice Mail System Configuration window, and select
                                Voice Servers and access Telephony Interface (Dialogic Analog)
                               Select the Dialogic Analog tab to configure the selected port(s) on your
                                Voice Server as follows:
                          The above information is provided by AVAYA Inc. as a guideline. See disclaimer on page 1
                                  ERICSSON MD-110 (RS-232)                                                                   5
                                                  Playback Volume = 2 (Default)
                                                  Number of Ports = Enter the number of ports in your system
                                         Note: The MAS service must be restarted to allow port enabling
                                                  Enable the port(s) by checking the Box field next to the Port field
                                                  Extension = Enter the port number in the field, i.e. 1 for the first
                                                  port, 2 for the second port, etc.
                                                  Incoming Ring Count = 1
                                                  Primary ID = Enter the port number again, i.e. 1 for first port, 2 for
                                                  port second port, etc.
                                                  Secondary ID = Leave Blank
                                       Return to the Voice Servers section and access PBX Integration.
                                       Access the General folder. Select Serial as the Integration Type.
                                        Max Time to Wait for Serial and Remote Integration Data (sec) = 6
                                       Access the Serial General tab and set the following values:
For multiple MAS servers, refer                   Packet Format = Ericsson MD-110
     to Consideration 8.3                         Extension Field Length in Packet = Number of digits in
                                                  extension
                                                  Maximum Number of Remote Service Sessions = 0
                                                  Log Serial Packets = Enable by checking the box
                                       Access the Serial NEC/Ericsson/DMID/ tab and set the following values:
                                                  Filler Character = x (Space or Zero)
                                                  Port Field Length = x (usually 2)
                                                  Tenant Number = x (usually 01)
                                                  First Port Number = x (1 or 01, depends on the PBX program)
                                                        Reminder: Verify value of x in switch.
                                  Note: Message Waiting (MWI) needs to be configured on the switch to
                                        accept the Filler character Space or Zero. If this is not possible
                                        then set the following registry value on the MAS to remove Filler
                                        characters for Message Waiting only, set the following registry
                                        value to 0:
                                  \\HKLM\Software\Octel\Geneva\Vis_IntegrationServiceMgr\MWI_MD110_FORMAT_WITH_SPACE
                                       Access the Serial Settings button from the Serial General tab and set:
                                                  Line Speed (Bits per Second) = 9600
                                                  Data Bits = 7
                                                  Stop Bits = 1
                                                  Parity = Even
                                  The above information is provided by AVAYA Inc. as a guideline. See disclaimer on page 1
                                 ERICSSON MD-110 (RS-232)                                                                   6
                                                 Flow Control = None
                                                 Connector = COM1
                                 Note: Verify these values within switch.
                                 After making these changes, stop and restart the MAS.
                                 Refer to Configuring the voicemail system within the Message
                                 Application Server Installation Guide. Ensure you are prompted to restart
                                 the Message Application Server services to apply these changes.
                                 7.0 INSTALLING THE INTEGRATION LINK
                                 Connect the data link cable to the COM1 serial port on the MAS. The DB25
                                 RS-232 connector plugs into the Ericsson-provided RS232 cable to the ICU.
                                 8.0 CONSIDERATIONS/ALTERNATIVES
Important notes regarding this   8.1      If a caller dials an invalid extension number from the automated
         integration                      attendant the Ericsson will send an error tone to the MAS and the call
                                          will be falsely connected. The MD-110 will then call back to the MAS
                                          port attempted to transfer the call. For this reason we recommend setting
                                          the system parameter Transfer Invalid Mailboxes to NO.
                                 8.2      Ensure the integration link is not configured for UPDATING. If this
                                          feature is enabled then MWI failures will occur. It will also generate
                                          alarms on the PBX.
                                 8.3      Procedure for adding more than one Message Application Server
                                          (MAS) when using RS-232 integration
                                    The following steps are for MAS 1 only:
                                          1) The first MAS is the only one that will have the RS-232 link from the
                                             PBX connected to COM1
                                          2) MAS 1 will also have the appropriate Serial integration (i.e. Serial
                                             General, NEC/Ericsson) according to the Configuration Note or the PBX
                                             used.
                                          3) Finally, within the Serial integration programming of MAS 1, configure
                                             the Maximum Number of Remote Service Sessions. For example, if
                                             there are 2 additional MAS servers, then the value should be 2.
                                    The following steps are for the additional MAS servers only:
                                          1) The remaining MAS servers will not have any integration link or any
                                             other cabling from the PBX or external devices.
                                 The above information is provided by AVAYA Inc. as a guideline. See disclaimer on page 1
ERICSSON MD-110 (RS-232)                                                                   7
         2) These MAS servers will have the PBX Integration programmed as
            Remote.
         3) Next, access the Remote tab from the PBX Integration General page and
            configure the 2 fields (Primary Remote Server Name and Secondary
            Remote Server Name) with MAS #1s info. You can not get integration
            data from any other MAS, so it must be MAS 1 only.
   After concluding these steps, save them, and continue with the remaining of
   the programming detailed on either the Configuration Note and/or the MM
   Installation Guide.
8.4      For external CLI (Caller ID) to work with the Ericsson one of the
         following MM patches is required:
      Software
                                              MAS Patch or Service Pack required
      Release
       MM1.1             Patch MAS110803 or newer; or Service Pack 9 (when available)
       MM 2.0            Patch MAS200601 or newer; or Service Pack 7 (when available)
       MM 3.0            Patch MM300103 or newer; or Service Pack 2 (when available)
                                            - continued on next page -
The above information is provided by AVAYA Inc. as a guideline. See disclaimer on page 1
ERICSSON MD-110 (RS-232)                                                                                                     8
                                              CHANGE HISTORY
 Revision               Issue           Reason for Change
                         Date
 Version A             03/20/03         GA
  Version B            04/11/03         Consideration 8.2 added
  Version C            12/18/03         Updated to meet MM Release 1.1
 Version D             09/16/04         Updated to meet MM Release 2.0
  Version E            04/22/05         Added Consideration 8.3
  Version F            04/11/06         Updated to meet MM Release 3.0
 Version G             08/10/06         Added Consideration 8.4 detailing patches required for CLID
 Version H             05/05/08         Updated to support MM 4.0
  Version I            05/16/08         Updated diagram page 1, removed Dialogic Driver Release from Section 2.0
  Version J              2/2/09         Updated to support MM 5.0
 Version K               07/09          Updated to support MM 5.1
  Version L            01/19/10         Added note indicator to titles of Section 2.0 and 3.1; added corresponding
                                        note in sidebar; removed word supported in same sections for MAS
                                        releases and PBX Software releases.
2010 AVAYA Inc. All rights reserved. All trademarks identified by the , SM and TM are registered trademarks,
servicemarks or trademarks respectively. All other trademarks are properties of their respective owners. The above
information is based on knowledge available at the time of publication and is subject to change without notice. Printed in
U.S.A.
AVAYA Inc.
1033 McCarthy Blvd
Milpitas, CA 95035-7912
(408) 577- 7000
http://www.avaya.com
The above information is provided by AVAYA Inc. as a guideline. See disclaimer on page 1