BuyLog Smart Catalog
BuyLog Smart Catalog
Industrial Solutions
BuyLog
Contact Information
Customer Service
For general customer service requests
Telephone 800-GE1-STOP (800-431-7867)
Email GE.1STOP_REPLY@GE.com
Post-Sales Service
For initiating or updating post-sales service issues and warranty cases
Web www.geelitenet.com (EliteNet)
Telephone 888-GE-RESOLVE (888-437-3765)
Publications Orders
For additional catalogs or other publications
Web www.geindustrial.com
Telephone 309-664-1513
GE Parts SuperCenter
For industrial renewal parts and components (also see page 9)
Web www.PartsSuperCenter.com
Telephone 800-727-8443
Motors
For standard or custom motors, 1-100,000 HP
Web www.geindustrial.com or www.gemotors.com
Telephone 800-541-7191
Motor Parts
For Genuine GE parts built to original designs using the latest materials and manufacturing processes
Telephone 800-458-0451
Email motorparts@ge.com
Need a knowledgeable service provider whos there when needed most? Calling 888-GE4-SERVice connects you with
over 100 years of power system expertise, including generation, delivery, utilization and control.
When you need onsite field service support call your local sales team or
888-GE4-SERVice
International or toll calls: 540-378-3280
Parts Super Center is your one-stop source for genuine renewal parts for mature GE products lines and
many current products. It also offers a variety of cost-effective services and solutions:
Factory tech support factory expertise remains even when factories do not
24-hour emergency service
Quick access to more than 300,000 part numbers
Over $30 million dollars in inventory
Fast turnaround - stock items shipped same day order is received
Inventory management programs, including JIT
Web-based electronic ordering
On-line publications and parts catalogs
Dedicated, cross-functional product teams
Customer satisfaction driven by six sigma quality
Transformers
Rome Plant Hickory Plant
Primary Substation Parts Bushing Potential Devices - Complete units
Load Tap Changers (Complete units and Inductrol Regulator Complete units and parts
parts) Step Voltage Regulator Parts
Replacement Units
Pittsfield Plant
Primary Substation Parts
Load Tap Changer Parts
Download both catalogs or just the one you need. Once down-
loaded, instantly access product information on- or offline.
Special Purpose Circuit Breakers Copper stabs, tin-plated for corrosion resistance,
PowerMark Gold Main Circuit Breakers make the connection reliable and permanent.
Arc Fault Circuit Interrupter
Dual Function GFCI/AFCI Ground Fault Heat-resistant thermoset cases and covers add
& Combination Arc Fault Circuit Breaker stability and structural rigidity.
Ground Fault with Self-Test Feature
Trips are easy to spot because handles trip to the
Ground Fault with Equipment Protection
center position.
Switching Neutral
HID Lighting Breaker The dedicated calibration screw is cemented (not
High Magnetic Breaker simply papered over) to prevent shifting. The result is
Molded Case Switch stable calibration for optimum trip performance.
Surge Arrester
TQ Breaker
At 1/2, THQP breakers are half the width of standard breakers, permitting the use of smaller
load centers that save money and space in both new construction and service upgrades. They
feature the same high-performance design, and meet the same stringent standards as other Q-
Line breakers. Our 1 THQL will remain the breaker of choice for many contractors. In applica-
tions where space and cost are not critical, theyre an excellent choice. But when size and money
are driving considerations, THQP breakers are the smart choice.
Enclosed circuit
breakers make it
easy and efficient
to install exterior
main breakers.
THQLSURGE surge
arresters are easy to
install and protect the
whole house comput-
ers, fax machines, televi-
Maximum protection sions, stereos, VCRs and
against all-too-common other sensitive electronic
electrical fires comes equipment from
from the new technology destructive surges.
built into GEs arc fault
circuit interrupters (AFCIs).
With its ability to detect
and interrupt arcing The NEC requires ground fault protection of receptacles outdoors and
caused by damaged wire in garages, bathrooms and spa areas. These ground fault circuit
insulation or a frayed extension cord, the AFCI takes interrupters eliminate the need for separate GFCI receptacles, protect
home and family protection to a new, higher level. against short circuits and overloads, and prevent shock by detecting
very low levels of current leaks and immediately shutting off power to
the circuit.
T M 42 4 20 C CU B
GE Identification Insert for Specials
G or T = Factory installed ground bar
B = Bottom feed main breaker
Type FL = Factory installed feed-through lugs
M = Main breaker D = Optional door for 6-8 circuit panel.
L = Main lug (Doors standard on all units 12
LM = Convertible circuits or greater)
PL = Main lug (Thermoplastic) W = White Front
T H QL 1 1* 15 GFT
GE Identification
Ground Fault/Arc Fault Circuit Interrupter
AF2 = 1- & 2-pole Combination Arc Fault
Interrupting Rating Circuit Interrupter
H = 10kAlC GFEP = 1- & 2-pole Ground Fault with
HH = 22kAlC Equipment Protection Interrupter30 mA
X = 65kAlC GFT = 1- & 2-pole Ground Fault
with Self-Test Feature Interrupter - 5 mA
DF = 1-pole Dual Function GFCI/AFCI Ground Fault
Type & Combination Arc Fault Circuit Interrupter
QL = 1" plug-in
QP = 1/2" plug-in
QB = 1" bolt-on Ampere Rating
Voltage
1 = 120/240V
Poles (1, 2, 3) 2 = 240V
*Omit character for THQP breakers, which are all 120/240V.
THQL2140 THQL32015
Arc Fault2
UL Listed
Arc-Fault Circuit Interrupters No. 1699
1 Pole, 120/240 Volts ac1
Ampere Rating Product Number
10,000 AIC
15 THQL1115AF2
20 THQL1120AF2
22,000 AIC
15 THHQL1115AF2
20 THHQL1120AF2
Std. Pkg. 10 Cartons of 1
As of Jan. 1, 2008, 2005 NEC requires combination AFCI.
1Combination AFCI compliant with 2008 NEC and later
2For 2-Pole shared neutral applications use two 1-pole circuit breakers with a handle tie. See DET-719 for more
details on our Arc Fault products. Arc Fault
Dual Function GFCI/AFCI Ground Fault & Combination Arc Fault Circuit Breaker
UL Listed (Available December 2014)
1 Pole, 120 Volts ac
Ampere Rating Product Number
10,000 AIC
15 THQL1115DF
20 THQL1120DF
22,000 AIC
15 THHQL1115DF
20 THHQL1120DF
Std. Pkg. 10 Cartons of 1
Switching Neutral
UL Listed. 10kAIC RMS symmetrical.
Standard 1- or 2-pole automatic breaker plus one fully-rated, non-automatic pole.
1-Pole Plus Switching Neutral 2-Pole Plus Switching Neutral
120/240 Volts ac 120/240 Volts ac
Ampere Rating Product Number Product Number
15 THQL21WY15 THQL31WY15
20 THQL21WY20 THQL31WY20
25 THQL21WY25 THQL31WY25
30 THQL21WY30 THQL31WY30 THQL21WY30
Std. Pkg. 5 cartons of 5 5 cartons of 3
"HID" Lighting
UL Listed as HID. HID breakers have been designed to handle the current and voltage
spikes that result when gaseous discharge lamps, including fluorescent and HID lamps,
are switched on and off.
1-Pole, 120/240 Volts ac 2-Pole, 120/240 Volts ac
Ampere Rating Product Number Product Number
10,000 AIC
15 THQL1115HID2 THQL2115HID
20 THQL1120HID2 THQL2120HID
30 THQL1130HID THQL2130HID
22,000 AIC
15 THHQL1115HID2 THHQL2115HID THQL2120HID
20 THHQL1120HID2 THHQL2120HID
30 THHQL1130HID THHQL2130HID
Std. Pkg. 5 cartons of 10 5 cartons of 5
2UL Listed as SWD (switching duty). Suitable for 120 volts ac fluorescent lighting loads.
High Magnetic
UL Listed. 10kAIC RMS symmetrical
High short circuit setting suitable for circuits with inherent high-inrush load currents.
1-Pole, 120/240 Volts ac
Ampere Rating Product Number
15 THQL1115HM
20 THQL1120HM
25 THQL1125HM
30 THQL1130HM
40 THQL1140HM THQL1140HM
50 THQL1150HM
Std. Pkg. 5 cartons of 10
THQL 120/240 Vac, Internal Common Trip with Factory Installed Shunt1 THQL1130ST1
# of Ampere 240 Vac
Poles Rating Wire Range2 Interrupting Rating Product Number
2 15 14-8 Cu/12-8 Al 10kA THQL2115ST1
2 20 14-8 Cu/12-8 Al 10kA THQL2120ST1
2 30 14-8 Cu/12-8 Al 10kA THQL2130ST1
2 35 8-3 Cu/8-3 Al 10kA THQL2135ST1
2 40 8-3 Cu/8-3 Al 10kA THQL2140ST1
2 45 8-3 Cu/8-3 Al 10kA THQL2145ST1
2 50 8-3 Cu/8-3 Al 10kA THQL2150ST1
2 60 8-3 Cu/8-3 Al 10kA THQL2160ST1
2 70 6-1/0 Cu/4-1/0 Al 10kA THQL2170ST1
2 80 6-1/0 Cu/4-1/0 Al 10kA THQL2180ST1 THQL2120ST1
2 90 6-1/0 Cu/4-1/0 Al 10kA THQL2190ST1
2 100 6-1/0 Cu/4-1/0 Al 10kA THQL21100ST1
3 20 14-8 Cu/12-8 Al 10kA THQL32020ST1
3 30 14-8 Cu/12-8 Al 10kA THQL32030ST1
3 40 8-3 Cu/8-3 Al 10kA THQL32040ST1
3 50 8-3 Cu/8-3 Al 10kA THQL32050ST1
3 60 8-3 Cu/8-3 Al 10kA THQL32060ST1
3 70 6-1/0 Cu/4-1/0 Al 10kA THQL32070ST1
3 80 6-1/0 Cu/4-1/0 Al 10kA THQL32080ST1
3 90 6-1/0 Cu/4-1/0 Al 10kA THQL32090ST1
3 100 6-1/0 Cu/4-1/0 Al 10kA THQL32100ST1
2Solid or stranded for 14-10 AWG.
THQL32020ST1
*Square D is a registered trademark of SNA Holdings, Inc. **QO is a registered trademark of the Square D Company.
Product Features
UL Listed (Panelboards No. 67)
60/75C Conductor Rating
Suitable for Use as Service Entrance Equipment when Installed
in Accordance with the National Electrical Code
22kAIC RMS symmetrical, Except Where Noted
6-42 circuit devices UL Listed for bottom mounted lugs by
installing complete unit (box, interior and front) upside down.
For a listing of CSA Listed load centers, visit geindustrial.com.
TLM2020CCU TPL412R
Note: See page 11-4, AL Series Lighting Panelboards as replacements for 300-600A load centers.
Note: See page 11-4, AL Series Lighting Panelboards as replacements for 300-600A load centers.
Product Features
UL Listed (Panelboards No. 67)
60C/75C Conductor Rating
Suitable for Use as Service Entrance Equipment when Installed
in Accordance with the National Electrical Code
22kAIC RMS symmetrical, Except Where Noted
6-42 circuit devices UL Listed for bottom mounted lugs by
installing complete unit (box, interior and front) upside down.
For a listing of CSA Listed load centers, visit geindustrial.com.
TM2020CCU TM820RCUFL
Load Center
1PH
Main Breaker
Outdoor NEMA 3R
Outdoor (NEMA 3R) Enclosure4
Main 1 Pole, 2 Pole, 1 Pole, 2 Pole, Total Main Wire Size
Ampere 1 1 1/2 1/2 1-pole Feed Box (AWG/kcmil) Equipment Product
Rating Spaces Spaces Spaces Spaces Spaces Type Number Cu-Al Ground Kit Number
100 12 5 20 8 22 Top R3A 4-1/0 TGK12 (order separately) TM1210RCU
TGK24 (order separately)
100 20 10 0 0 30 Top R4 4-1/0 TGK24 (order separately) TM2010RCU
125 12 5 20 8 22 Top R3A 1-2/0 TGK12 (order separately) TM1212RCU
TGK24 (order separately)
125 24 12 0 0 24 Top R4 1-2/0 TGK24 (order separately) TM2412RCU
150 8 4 16 6 16 Top R5 1-250 (Cu), 2/0-250 (Al) TGK24 (order separately) TM815RCUFL
150 16 8 32 14 32 Top R5 1-3/0 (Cu), 2/0-3/0 (Al) TGK24 (order separately) TM1615RCU
TGK32 (order separately)
150 24 12 12 4 30 Top R6 1-3/0 (Cu), 2/0-3/0 (Al) TGK24 (order separately) TM2415RCU
TGK32 (order separately)
150 24 12 36 18 42 Top R39 1-250 (Cu), 2/0-250 (Al) TGK24 (order separately) TM2415R42
Bottom
150 32 16 0 0 32 Top R7 1-3/0 (Cu), 2/0-3/0 (Al) TGK32 (order separately) TM3215RCU
200 8 4 16 6 16 Top R5 1-250 (Cu), 2/0-250 (Al) TGK32 (order separately) TM820RCUFL
200 20 10 40 18 40 Top R6 1-250 (Cu), 2/0-250 (Al) TGK24 (order separately) TM2020RCU
TGK42 (order separately)
200 24 12 36 18 42 Top R39 1-250 (Cu), 2/0-250 (Al) TGK24 (order separately) TM2420R42
Bottom
200 32 16 16 6 40 Top R7 1-250 (Cu), 2/0-250 (Al) TGK32 (order separately) TM3220RCU
200 40 20 0 0 40 Top R8 1-250 (Cu), 2/0-250 (Al) TGK42 (order separately) TM4020RCU
225 8 4 16 6 16 Top R5 1-250 (Cu), 2/0-250 (Al) TGK24 (order separately) TM822RCUFL
225 42 20 0 0 42 Top R8 1-300 (Cu), 2/0-300 (Al) TGK42 (order separately) TM4222RCU
4100-225 amp devices have removable closing caps. Larger ampere devices require field-cut openings. Order hubs separately. See page 1-27.
Note: See page 11-4, AL Series Lighting Panelboards as replacements for 300-600A load centers.
Product Features
UL Listed (Panelboards No. 67)
60/75C Conductor Rating
Suitable for Use as Service Entrance Equipment when Installed
in Accordance with the National Electrical Code
22kAIC RMS symmetrical Short-circuit Rating Standard
Bottom feed models available where noted with a B suffix.
For a listing of CSA Listed load centers, visit geindustrial.com.
Copper breaker mounting stabs with aluminum bus1
Note: See page 11-4, AL Series Lighting Panelboards as replacements for 300-600A load centers.
Note: See page 11-4, AL Series Lighting Panelboards as replacements for 300-600A load centers. This table continued on next page
Load Center
3PH
Main Breaker
Outdoor NEMA 3R
Outdoor (NEMA 3R) Enclosure
Main 1 Pole, 2 Pole, 3 Pole, Total Main Wire Size
Ampere 1 1 1 1-pole Feed Box (AWG/kcmil) Equipment Product
Rating Spaces Spaces Spaces Spaces Type Number Cu-Al Ground Kit Number
100 18 8 6 18 Top R4 6-1/0 (Cu), TGK24 (order separately) TM18410R
4-1/0 (Al) TGK32 (order separately)
125 30 14 10 30 Top R7 1-3/0 (Cu), TGK32 (order separately) TM30412R
2/0-3/0 (Al)
150 24 12 8 24 Top R6 1-3/0 (Cu), TGK32 (order separately) TM24415R
2/0-3/0 (Al)
150 30 14 10 30 Top R7 1-3/0 (Cu), TGK32 (order separately) TM30415R
2/0-3/0 (Al)
200 30 14 10 30 Top R7 1-250 (Cu), TGK32 (order separately) TM30420R
2/0-250 (Al)
200 42 20 14 42 Top R8 1-250 (Cu), TGK42 (order separately) TM42420R
2/0-250 (Al)
225 42 20 14 42 Top R8 1-300 (Cu), TGK42 (order separately) TM42422R
2/0-300 (Al)
Note: See page 11-4, AL Series Lighting Panelboards as replacements for 300-600A load centers.
Riser Panels
Indoor (NEMA 1) Enclosure
Main 1 Pole, 2 Pole, 1 Pole, 2 Pole, Total Main Wire Size
Ampere 1 1 1/2 1/2 1-pole Feed Box (AWG/kcmil) Equipment Product
Rating Spaces Spaces Spaces Spaces Spaces Front Type Type Number Cu-Al Ground Kit Number
125 20 10 40 20 40 Combination Top 9A 6-2/0 TGK12 (order TLM2012CCURP
Flush/Surface Front separately)
Spa Panels
Outdoor (NEMA 3R) Enclosure
Main 1 Pole, 2 Pole, 1 Pole, 2 Pole, Total Main Wire Size
Ampere 1 1 1/2 1/2 1-pole Load Center Feed Box (AWG/kcmil) Equipment Product
Rating Spaces Spaces Spaces Spaces Spaces Type Type Number Cu-Al Ground Kit Number
125 4 2 8 4 8 Factory Included Top 1-2/0 TGL1 installed TL412R250GF
50A GFCI Bottom
125 4 2 8 4 8 Factory Included Top 1-2/0 TGL1 installed TL412R260GF
60A GFCI Bottom
Main
Ampere 1 Pole, 2 Pole, 1 Pole, 2 Pole, Total 1-pole Enclosure Bypass UL Agency Product
Rating 1 Spaces 1 Spaces 1/2 Spaces 1/2 Spaces Spaces Type Front Type Type Incoming Certification Number
Application Data
Main Wire Size
Product Box Unit Width Unit Height Depth Factory Inst. Field Inst. (AWG/kcmil) Equipment
Number Number (in inches) (in inches) (in inches) Svcs Disc Svcs Disc Cu-Al Ground Kit
TSL210CFCU R12 14 23-1/2 4-7/8 THQP/THQL 6-2/0 TGL1 installed
TSL210CSCU R12 14 23-1/2 4-7/8 THQP/THQL 6-2/0 TGL1 installed
TSL412CSCU R12 14 23-1/2 4-7/8 THQP/THQL 6-2/0 TGL1 installed
TSL420CFCU R14 14 30-3/4 5-3/4 THQP/THQL 1-250 TGL1 installed
TSL420CSCU R14 14 30-3/4 5-3/4 THQP/THQL 1-250 TGL1 installed
TM10RMC R32 16 17 5 TQD Field Installed4 2-250
TM12RMC R32 16 17 5 TQD Field Installed4 2-250
TM15RMC R32 16 17 5 TQD Field Installed4 2-250
TM20RMC R32 16 17 5 TQD Field Installed4 2-250
Application Data
Main Wire Size
Product Box Unit Width Unit Height Depth Factory Inst. Field Inst. (AWG/kcmil) Equipment
Number Number (in inches) (in inches) (in inches) Svcs Disc Svcs Disc Cu-Al Ground Kit
TSF420CSCU R16 16-3/4 33 6-3/16 THQMV THQL/THHQL 1-300 TGK12 (order separately)
Application Data
Main Wire Size
Product Box Unit Width Unit Height Depth Factory Inst. (AWG/kcmil) Equipment
Number Number (in inches) (in inches) (in inches) Svcs Disc Cu-Al Ground Kit
TSM415CSCU R36 14 28-1/2 4-1/2 THQMV 6-350 TGL2 included
TSM815CSCU R16 16-3/4 33 6-3/16 THQMV 1-300 TGK12 (order separately)
TSM815CSFL R37B 14 31-3/4 4-1/2 THQMV 6-350 TGK24 included
TSM420CSCU R36 14 28-1/2 4-1/2 THQMV 6-350 TGL2 included
TSM820CSCU R16 16-3/4 33 6-3/16 THQMV 6-350 TGK12 (order separately)
TSM820CSFL R37B 14 31-3/4 4-1/2 THQMV 6-350 TGK24 included
Application Data
Main Wire Size
Box Unit Width Unit Height Depth Factory Inst. (AWG/kcmil) Equipment
Product Number Number (in inches) (in inches) (in inches) Svcs Disc Cu-Al Ground Kit
TSM1610CFCU R19 14-3/4 28-1/2 7-5/16 THHQL 12-2/0 TGK12 (order separately)
TSM1212CFCU R19 14-3/4 28-1/2 7-5/16 THHQL 12-2/0 TGK12 (order separately)
TSM1612CFCU R19 14-3/4 28-1/2 7-5/16 THHQL 12-2/0 TGK12 (order separately)
TSM2020CFCU R17 16-3/4 34-1/4 7-5/16 THQMV 1-300 TGK12 (order separately)
TSM1610CSCU R20 14-3/4 27-5/16 5-7/16 THHQL 12-2/0 TGK12 (order separately)
TSM1212CSCU R20 14-3/4 27-5/16 5-7/16 THHQL 12-2/0 TGK12 (order separately)
TSM1612CSCU R20 14-3/4 27-5/16 5-7/16 THHQL 12-2/0 TGK12 (order separately)
TSM2020CSCU R18 14-3/4 33 6-5/16 THQMV 1-300 TGK12 (order separately)
Application Data
Main Wire Size
Box Unit Width Unit Height Depth Factory Inst. (AWG/kcmil) Equipment
Product Number Number (in inches) (in inches) (in inches) Svcs Disc Cu-Al Ground Kit
TSM3220UWCU R28 22-1/2 27-7/8 6-1/4 THQMV 1-300 TGK12 (order separately)
TSM4020UWCU R29 22-1/2 34-7/8 6-1/4 THQMV 1-300 TGK12 (order separately)
Application Data
Main Wire Size
Box Unit Width Unit Height Depth Factory Inst. (AWG/kcmil) Equipment
Product Number Number (in inches) (in inches) (in inches) Svcs Disc Cu-Al Ground Kit
TSM2420UF42 R17 16-3/4 34-1/4 7-5/16 THQMV 1-4/0 TGK12 (order separately)
TSM3220UFCU R27 14-9/16 43-5/8 7-3/16 THQMV 1-300 TGK12 (order separately)
TSM2022UFCU R21 14-9/16 43-5/8 7-3/16 THQMV 1-300 TGK12 (order separately)
TSM3222UFCU R22 16-3/16 48-1/8 7-3/16 THQMV 1-300 TGK12 (order separately)
TSM2420US42 R17 16-3/4 34-1/4 7-5/16 THQMV 1-4/0 TGK12 (order separately)
TSM3220USCU R27 14-9/16 48-1/8 6-3/16 THQMV 1-300 TGK12 (order separately)
TSM2022USCU R26 14-9/16 43-5/8 6-3/16 THQMV 1-300 TGK12 (order separately)
TSM3222USCU R27 14-9/16 48-1/8 6-3/16 THQMV 1-300 TGK12 (order separately)
Application Data
Main Wire Size
Box Unit Width Unit Height Depth Factory Inst. (AWG/kcmil) Equipment
Product Number Number (in inches) (in inches) (in inches) Svcs Disc Cu-Al Ground Kit
TSLR412CSCU R31 14-9/16 33-9/16 6-3/16 Field Installed2 6-350 TGK12 (order separately)
TSLB412CSCU R12 14 23-1/2 4-7/8 Field Installed2 6-350 TGL1 installed
TSMR1212CSCU R30 14-9/16 40-1/2 6-3/16 THHQL 6-350 TGK12 (order separately)
TSMB1212CSCU R20 14-3/4 27-5/16 5-7/16 THHQL 12-2/0 TGK12 (order separately)
TSMR415CSCU R31 14-9/16 33-9/16 6-3/16 THQMV 6-350 TGK12 installed
TSMR2015CSCU R30 14-9/16 40-1/2 6-3/16 THQMV 6-350 TGK12 (order separately)
TSMB2015CSCU R18 14-3/4 33 6-5/16 THQMV 1-300 TGK12 (order separately)
TSLB420CSCU R14 14 30-3/4 5-3/4 Field Installed2 6-350 TGL1 installed
TSLR420CSCU R31 14-9/16 33-9/16 6-3/16 Field Installed2 6-350 TGK12 (order separately)
TSMR420CSCU R31 14-9/16 33-9/16 6-3/16 THQMV 6-350 TGK12 installed
TSMR2020CSCU R30 14-9/16 40-1/2 6-3/16 THQMV 6-350 TGK12 (order separately)
TSMB2020CSCU R18 14-3/4 33 6-5/16 THQMV 1-300 TGK12 (order separately)
2THQL and THHQL only. 125 amp max. TQDL is obsolete.
Application Data
Main Wire Size
Box Unit Width Unit Height Depth Factory Inst. (AWG/kcmil) Equipment
Product Number Number (in inches) (in inches) (in inches) Svcs Disc Cu-Al Ground Kit
TSMR015CSGP R32A 18-7/8 18-9/16 5 THQD 2-250
TSMR020CSGP R32A 18-7/8 18-9/16 5 THQD 2-250
TSMR415CSCUGP R40 14 32 4-1/2 THQMV 6-350 TGL2 included
TSMR420CSCUGP R40 14 32 4-1/2 THQMV 6-350 TGL2 included
Application Data
Main Wire Size
Box Unit Width Unit Height Depth Factory Inst. (AWG/kcmil) Equipment
Product Number Number (in inches) (in inches) (in inches) Svcs Disc Cu-Al Ground Kit
TSMR415CSFLFMG R36A 14 28-1/2 4-1/2 THQMV 6-350 TGL2 included
TSMR420CSFLFMG R36A 14 28-1/2 4-1/2 THQMV 6-350 TGL2 included
TSMR815CSFLFMG R37A 14 31-3/4 4-1/2 THQMV 6-350 TGK24 included
TSMR820CSFLFMG R37A 14 31-3/4 4-1/2 THQMV 6-350 TGK24 included
TSMR2020CSCUFMG R403 14 34-1/2 4-1/2 THQMV 6-350 TGK24 included
1Use FMG unit if Ringless standard UL design is required by your local utility.
2No feed through lugs.
3Knock outs are the same as R36A.
4Feed-thru lugs provided.
Class 320
Main 1 Pole, 2 Pole, 1 Pole, 2 Pole, Total
Ampere 1 1 1/2 1/2 1-pole Enclosure Bypass UL Agency Product
Rating Spaces Spaces Spaces Spaces Spaces Type Front Type Type Incoming Certification Number
320 24 12 32 14 40 Outdoor Surf/Semi None UG UL TM2432RMS1,2,3
(NEMA 3R)
400 0 0 0 0 0 Outdoor Surf/Semi Lever Bypass UG UL TSDR040UFCU4
(NEMA 3R)
300 8 4 16 6 16 Outdoor Surface Lever Bypass UG UL TSDR830USCU4
(NEMA 3R) FMG
400 8 4 16 6 16 Outdoor Surface Lever Bypass UG UL TSDR840UFCU4
(NEMA 3R) FMG
400 24 12 32 14 40 Outdoor Surf/Semi Lever Bypass UG UL TM2440RMRS1,2,3
(NEMA 3R)
400 24 12 32 14 40 Outdoor Surf/Semi None UG UL TM2440RMS1,2,3
(NEMA 3R) EUSERC
400 24 12 32 14 40 Outdoor Surf/Semi Lever Bypass UG UL TMH2440RMRS1,2,3,4
(NEMA 3R) Xcel
400 24 12 32 14 40 Outdoor Surf/Semi None UG UL TMH2440RMS1,2,3,4
(NEMA 3R)
320 0 0 0 0 0 Outdoor Surf/Semi Lever Bypass UG UL TSD032UFCU4
(NEMA 3R)
320 24 12 32 14 42 Outdoor Surf/Semi Link Bypass UG UL TSDA2432UC424
(NEMA 3R) EUSERC
400 24 12 32 14 42 Outdoor Surf/Semi Link Bypass UG UL TSDA2440UC424
(NEMA 3R) EUSERC
1200A main breaker factory installed. Space provided for field mounted TQD-WL sub feed.
2For semi-flush applications, order surface enclosure load center and field installed kit, Product number SF400.
3Stud provisions only provided.
422 kAIC.
Application Data
Main Wire Size
Product Box Unit Width Unit Height Depth Factory Inst. Field Inst. (AWG/kcmil) Equipment
Number Ringless Number (in inches) (in inches) (in inches) Main Breaker Main Breaker Cu-Al Ground Kit
TM2432RMS No R24 30-1/4 40 6 TQD THQL (1) 800 or (2) 400 compression type; (2) TGL2
(1) 1000 or (2) compression type; (order separately)
(1) 1000 or (2) 350 pressure type
TM2440RMS No R24 30-1/4 40 6 TQD TQD (1) 800 or (2) 400 compression type; (2) TGL2
(1) 1000 or (2) 350 pressure type (order separately)
TMH2440RMS No R24 30-1/4 40 6 THQD THQD (1) 800 or (2) 400 compression type; (2) TGL2
(1) 1000 or (2) 350 pressure type (order separately)
TSDA2432UC42 No R24 30-1/4 40 6 THQD THQL/THHQL (1) 800 or (2) 400 compression type (2) TGL2
(order separately)
TSDA2440UC42 No R24 30-1/4 40 6 THQD TQD/THQD (1) 800 or (2) 400 compression type (2) TGL2
(order separately)
TSD032UFCU No R33 30-1/4 33 6-3/32 THQD THQL/THHQL (1) 800 or (2) 400 compression type (2) TGL2
(order separately)
TM2440RMRS Yes R24 30-1/4 40 6 TQD TQD (1) 800 or (2) 400 compression type; (2) TGL2
(1) 1000 or (2) 350 pressure type (order separately)
TMH2440RMRS Yes R24 30-1/4 40 6 THQD THQD (1) 800 or (2) 400 compression type; (2) TGL2
(1) 1000 or (2) 350 pressure type (order separately)
TSDR040UFCU Yes R33 30-1/4 33 6-3/32 THQD TQD/THQD (1) 800 or (2) 400 compression type (2) TGL2
(order separately)
TSDR840UFCU Yes R33 30-1/4 33 6-3/32 THQD TQD/THQD (1) 800 or (2) 400 compression type (2) TGL2
(order separately)
THLK200
For replacement of main lugs on 125 amp load centers; TLM load centers include main lugs.
PowerMark Gold main lug kits - TMLK200
Door Lock
Standard Product
Description Package Quantity Number
For indoor load centers larger than 12 circuits (Does not fit TPL412) 10 TDL106
TDL106
Circuit Directory
Standard Product
Description Package Quantity Number
Card and holder with pressure-sensitive backing. 1 TD42
Mounts inside the door.
TD42
Touch-up Paint
Standard Product
Description Package Quantity Number
12 3/4 oz. spray can of light gray enamel 1 TSP61
TSP61
Door Handle
Standard Product
Description Package Quantity Number
Replacement Door Handle Universal 1 TRL22
TRL22
LCCROSSARM
For main lug load centers utilizing a back fed branch breaker as a main
THQLRK4
Handle Locks - Padlocking
Product
Description Breaker Type Number
THQP Padlocking Handle Lock THQP TQPPL
THQL Padlocking Handle Lock THQL THP100
TQD Padlocking Handle Lock TQD TQDPLD1
THT1
Handle Ties
Product
Description Breaker Type Number
Handle Ties for THQP Breakers - Solid Snap-on THQP THT11
Trip Indicating
Handle Ties for THQP Breakers - For 2 THQPs THQP THT21
separated by 2 side-by-side THQPs
TQB
Snap-on Handle Tie - Trip Indicating TQC TQHT11 THT104
TQL
TQB
Snap-on Handle Tie - Solid TQC THT1041
TQL
TQB
Multiwire Branch Breaker TQ3HTK2
TQC
Handle Tie Kits TQ4HTK3
TQL
TQHT1
TLSB TQDSB
Service Barrier Kits for PowerMark Meter Socket Load Centers
Field installed service barrier kits.
These kits are normally supplied with service entrance load centers
and main circuit breaker kits
Service Barriers UL listed (Panelboards No. 489) and compliant TQDSBR TQDSFSBP
to UL 67 standards
Product
Description Number
MSLC Bus Service Barrier TSMBSB
MSLC Lug Service Barrier TSMLSB
MSLC Service Barrier 2P Module TSMLSB2P
MSLC Lug Service Barrier Bus Filler TSMLSBF
MSLC Lug Service Barrier Shutter TSMLSBS
MSLC Lug Service Barrier Reverse Feed TSMLSBR
TSMBSB TSMLSB
Surge Protectors
Product
Description Number
SurgePro AC 27KA Panel-Mount Surge Protector THQLSURGE
G G G E
Breaker Fill
Breaker Symbol 1 THQL 1/2 THQP
1
TL240SCU, RCU
1 2
TL270SCU, RCU TL510RT
C C
B 14-1/0 12-1/0
C
C 6-2/0 6-2/0
D 1-300 2/0-300
E 1-300 1-300
F 6-1 6-1
TPL412C, TL412C, TPL412R, TL412R1, TPL412CT, TL412CT
G 6-3 6-3 TL412R2, TL412R250GF, TL412R260GF TPL412RT, TL412RT1
C MAIN
E
F F F F BREAKER
F MAIN MAIN
F F BREAKER BREAKER
SUBFEED
LUGS
TM860FCUGEN, TLM830FCUGEN,
TLM612FCU, SCU TLM812FCU, SCU, TM815RCUFL TM860SCUGEN, TLM830SCUGEN,
FCUD, SCUD, RCU FCUD, SCUD, RCU TM820RCUFL TM860RCUGEN, TLM830RCUGEN
C C C C C C C C C C E
MAIN
MAIN MAIN
MAIN C C MAIN E
C
F F
C MAIN C
Breaker Fill
Breaker Symbol 1 THQL 1/2 THQP
1
1 2 TM2020CCU, TM2020RCU
TM2010CCU, TM2010RCU TLM2020CCU, TLM2020RCU
C C E
MAIN C E
C E MAIN
MAIN
MAIN
TM3220CCU, TM3220RCU,
TLM2420C42, TM2415C42 TM3210CCU TM3215CCU, TM3215RCU
TLM3220CCU, TLM3220RCU
MAIN MAIN
C E C E
MAIN
MAIN
C
C E
MAIN
Breaker Fill
MAIN
Breaker Symbol 1 THQL 1/2 THQP C C D
MAIN
1 C C D
1 2
MAIN
MAIN MAIN
C C D C C C D
MAIN
D D D C C C C C C C
MAIN
Breaker Fill
Breaker Symbol 1 THQL 1/2 THQP
1
1 2
MAIN MAIN
C C D C C C D
A C BB C
WHM
MAIN
WHM
A
A
A
C
WHM WHM
WHM
MAIN
A
A Load
Load D D C
B
A
A A
A A E
A
SPACE PROVIDED
WHM FOR 110A PARALLEL WHM
MAIN BREAKER MAIN
BREAKER
WHM
MAIN
MAIN BREAKER
BREAKER
C C C C
C C
C C
WHM
MAIN
BREAKER
WHM
MAIN
BREAKER
C
C C
C
D
C E
C WHM MAIN
BREAKER
WHM
C E
MAIN
D DC
C MAIN C E
A MAIN
BREAKER
Sub feed lugs WHM
A
WHM
B
A PH B PH
NEUTRAL
N
TSM815CSFL, TSM820CSFL, TSMF815CSFL, TSM3220USCU, TSM3220UFCU, TSM3222USCU,
TSM2420UF42 TSMF820CSFL, TSMR815CSFLFMG, TSM3220UWCU
TSM3222UFCU
TSMR820CSFLFMG
WHM MAIN
BREAKER WHM
C E
WHM
MAIN
BREAKER
WHM
MAIN
BREAKER
200A
MAIN
Main
Breaker
CC C D
D D C
L1 N L2
MAIN
BREAKER
E WHM
A PH B PH
NEUTRAL
TM2440RMRS, TM2440RMS,
TSMR2020CSCUFMG TSM2022USCU, TSM2022UFCU
TMH2440RMS, TMH2440RMRS
Space for
Field-installed
Breaker
WHM Line
C
C
C
MAIN
C E WHM
L1 N L2
MAIN C E
C
Neutral
WHM WHM
MAIN
C E
MAIN MAIN
T
Rev. 11/13 www.geindustrial.com BuyLog Catalog 1-37
Data subject to change
without notice
Load Centers and Circuit Breakers Section 1
PowerMark Gold and Plus Load Centers
Circuit Breakers
Indoor Enclosures
Knockouts
Symbol A B C D E F G H J K L M N P Q R S T U V W X Y Z
5/16
3/8 3/8 3/8
1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2
3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4
Conduit 1 1 1 1 1 1 1 1 1 1 1 1 1
Size 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4
in 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2
inches 2 2 2 2 2 2 2 2 2 2
2 1/2 2 1/2 2 1/2 2 1/2 2 1/2 2 1/2 2 1/2 2 1/2
3 3 3
3 1/2 3 1/2 3 1/2
4
C G
HD Y A H Z
K
Q Q
A A
H Q M A
H D B
K H A
G K D D
D
G D A D F A C
A
A Y Y
D D A M H
K H Y G Z
B D
B
Box 2A Box 3A Box 4, 6, 7, 8, 9, 11, 12, 13, 14 Box 4A, 9A
B T J GUB V GJ D K B D
C B C SB C
B B B D B B B B D
H P K D
K
B B B B D
K
S B S A A C
P B J K
B A
K AA
AA
B R
C
H A D
D
A D
CN B
D
D
B
A C A A B
D B
B P A B B D
D B B
B C N C B D B
A
D
B
D B
D D
A B B
S C
D
P
J
S K K A BP A B
A
P B C
C K C C
T B B J G J B
Box 15 Box 16 Box 17 Box 18
Knockouts
Symbol A B C D E F G H I J K L M N P Q R S T U V W X Y Z AA BB CC DD
9/32
3/8 3/8
1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2
9/16
3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4
Conduit 1 1 1 1 1 1 1 1 1 1 1 1 1 1
Size 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4
in 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2
Inches 2 2 2 2 2 2 2 2 2 2 2 2 2
2 1/2 2 1/2 2 1/2 2 1/2 2 1/2 2 1/2 2 1/2 2 1/2 2 1/2
3 3 3
3 1/2 3 1/2 3 1/2 3 1/2
4 4
Q R AK D
D
A
Q U U
Q R
D H J
Q D B
Box R3A, R5A, R6A Box R3, R4, R5, R6, R7 Box R8 Box R4A, R7A
Mounting provided
for universal hubs
R L
C L
J C B C
C
B R K
P R K K
J B
P
B B BC C K
B C C K
T J G V U B
Knockouts
Symbol A B C D E F G H J K L M N P Q R S T U V W X Y Z AA BB CC DD EE FF
5/32
3/8 3/8 3/8
1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2
3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4
Conduit 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
Size 1 1/4 1 1/4 1 1/4 1/1/4 1/1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4
in 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2
inches 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2
2 1/2 2 1/2 2 1/2 2 1/2 2 1/2 2 1/2 2 1/2 2 1/2 2 1/2 2 1/2 2 1/2
3 3 3
3 1/2 3 1/2 3 1/2 3 1/2
4 4
A A
F
B
B C B B C EE
EE
G B B
CC C C CC
C C G B B B B B
CC CC
B B B C C B B B B
B B B B
C C C B B B B
BB
A B B
B A
B C
B C
B BB
B
B BB CC
C B
Box R16 B
B C C
B B B B G
B B K C A
C
B B B
CC C C G B B CC C
B Q BB C CC
B B B
C C BBBB A
B
Box R17, R18 Box R19, R20
S S
Z Z
Z
S S
D R R
B K K
G R K G R
B AA
D AA
C D
K
B D D
Knockouts
Symbol A B C D E F G H J K L M N P Q R S T U V W X Y Z AA BB CC DD EE FF
5/32
3/8 3/8 3/8
1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2
3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4
Conduit 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
Size 1 1/4 1 1/4 1 1/4 1/1/4 1/1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4
in 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2
inches 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2
2 1/2 2 1/2 2 1/2 2 1/2 2 1/2 2 1/2 2 1/2 2 1/2 2 1/2 2 1/2 2 1/2
3 3 3
3 1/2 3 1/2 3 1/2 3 1/2
4 4
B BB B R
BB A
B L
EE EE BB BB B
G G C
B C B B
B B B B B B B C
C BB C BB B
B C B
R
A
B L
C G G
B FF FF
B C
P P
Box R31
A B B A B
HUB
FF FF B
Box R32 Box R32A
9/32 CC CC CC
EE E EE
GG
Box R40
Knockouts
Symbol A B C D E F G H J K L M N P Q R S T U V W X Y Z AA BB CC DD EE FF GG
5/32
3/8 3/8 3/8
1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2
3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4
Conduit 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
Size 1 1/4 1 1/4 1 1/4 1/1/4 1/1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4
in 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2
inches 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2
2 1/2 2 1/2 2 1/2 2 1/2 2 1/2 2 1/2 2 1/2 2 1/2 2 1/2 2 1/2 2 1/2 2 1/2
3 3 3 3
3 1/2 3 1/2 3 1/2 3 1/2
4 4
D R R D K K K
D G D R R
AA AA D G D
D D D D D D D D D D D D D D D D
9/32 CC CC CC 9/32 CC CC CC
D B D B D
B B
EE E G G EE E EE L L
D D D D D
GG GG W
HUB
EE EE
C C C C
EE
C C
EE 9/32 CC CC CC
9/32
C C C C C
K
EE C C
C C EE E EE
C d C C
GG
T MM 6 6 20 R F
GE Identification Special
MEG Approved
Type
MM = Mini Mod Ring Type
Enclosures
MMR = Mini Mod Ringless
R = Type 3R rainproof
Socket Positions
1-6
Product Features
UL Listed (Panelboards No. 67)
Indoor/Outdoor Construction
Ring-Type and Ringless Meter Sockets
Bondable Neutral, Strap Included
11-inch Mounting Z Rail Included
Swing Away Mounting Feet Factory Installed
Underground, incoming feed only
TMM4412R
Ring Type Socket1
Main Standard MEG
Ampere Main Wire Size Service Equipment Product Product
Socket Amps No. of Sockets Rating AWG/kcmil Cu/A Ground Ground Number Number3
125 A 2 200 (1) 6 -300 6-2/0 14-4 TMM2212R2 TMM2212RF2
125 A 3 400 (1) 6 -600 or (2) 2/0 -250 4-300 14-4 TMM4312R TMM4312RF
125 A 4 400 (1) 6 -600 or (2) 2/0 -250 4-300 14-4 TMM4412R TMM4412RF
125 A 5 600 (2) 250 - 500 4-300 14-4 TMM6512R TMM6512RF
125 A 6 600 (2) 250 - 500 4-300 14-4 TMM6612R TMM6612RF
200 A 2 400 (2) 250 - 500 4-300 14-4 TMM4220R Use TMM6320RF
200 A 3 600 (2) 250 - 500 4-300 14-4 TMM6320R TMM6320RF
200 A 4 600 (2) 250 - 500 4-300 14-4 TMM6420R TMM6420RF
Use Meter Mod III
200 A 5 600 (2) 250 - 500 4-300 14-4 TMM6520R
or Ringless
Use Meter Mod III
200 A 6 600 (2) 250 - 500 4-300 14-4 TMM6620R
or Ringless
installed, selected from table below. socket assembly to keep meter socket from detaching from base. These are
The short circuit rating is limited to the lowest interrupting rating required in all MEG areas as of January 2016.
4Includes factory installed fifth jaw.
of any tenant breaker installed. 5Units with HB suffix have a factory installed horn bypass included.
Replacement breakers shall be of the same manufacturer and
type and shall have an interrupting rating equal to or greater than
the interrupting rating of any tenant breaker presently installed in
this device.
Tenant Main Breaker Frame UL Listed AIC Rating
TMQD 100,000
TMQL 42,000
THQD 22,000
THHQL 22,000
TQD 10,000
THQL 10,000
GE breakers rated 10,000 AIC or greater when installed on the load side of the
Mini Mod III are protected for the interrupting rating per the UL Listing marked
on the tenant breaker.
TMQD
Mini Mod III Factory Optional Lug Kit and Optional Compression Lug Kit
Phase
GE Lug Kit GE Lug Kit
Main Mini Mod Amp. Rating Wire Size Product Number Wire Size Product Number Lugs Per Kit
(3) #4-300 TMPAL40
TMM4312R, TMM4312RF 125
(2) 250-500 TMPAL30
(3) #4-300 TMPAL40
TMMR4312R, TMMR4312RF, TMMR4312RHB 125
(2) 250-500 TMPAL30
(3) #4-300 TMPAL40
TMM4412R, TMM4412RF 125
(2) 250-500 TMPAL30
(3) #4-300 TMPAL40
TMMR4412R, TMMR4412RF, TMMR4412RHB 125
(2) 250-500 TMPAL30
(3) #4-300 TMPAL40
TMM6512R, TMM6512RF 125
(1) 2/0-600 or (2) #6-250 TMPAL30
(3) #4-300 TMPAL40
TMMR6512R, TMMR6512RF, TMMR6512RHB 125
(1) 2/0-600 or (2) #6-250 TMPAL30
(3) #4-300 TMPAL40
TMM6612R, TMM6612RF 125
(1) 2/0-600 or (2) #6-250 TMPAL30
(3) #4-300 TMPAL40
TMMR6612R, TMMR6612RF, TMMR6612RHB 125
(1) 2/0-600 or (2) #6-250 TMPAL30 2 studs per phase,
(3) #4-300 TMPAL40 Compression TMM6CLL double stack for up to
TMM4220R 200
(1) 2/0-600 or (2) #6-250 TMPAL30 2 conductors per phase,
(3) #4-300 TMPAL40 kit includes 3 lug landing pads
TMMR4220R, TMMR4220RF, TMMR4220RHB 200
(1) 2/0-600 or (2) #6-250 TMPAL30 (1 kit per device)
(3) #4-300 TMPAL40
TMM6320R, TMM6320RF 200
(1) 2/0-600 or (2) #6-250 TMPAL30
(3) #4-300 TMPAL40
TMMR6320R, TMMR6320RF, TMMR6320RHB 200
(1) 2/0-600 or (2) #6-250 TMPAL30
(3) #4-300 TMPAL40
TMM6420R, TMM6420RF 200
(1) 2/0-600 or (2) #6-250 TMPAL30
(3) #4-300 TMPAL40
TMMR6420R, TMMR6420RF, TMMR6420RHB 200
(1) 2/0-600 or (2) #6-250 TMPAL30
(3) #4-300 TMPAL40
TMM6520R 200
(1) 2/0-600 or (2) #6-250 TMPAL30
(3) #4-300 TMPAL40
TMMR6520R, TMMR6520RF, TMMR6520RHB 200
(1) 2/0-600 or (2) #6-250 TMPAL30
(3) #4-300 TMPAL40
TMM6620R 200
(1) 2/0-600 or (2) #6-250 TMPAL30
(3) #4-300 TMPAL40
TMMR6620R, TMM6620RF, TMMR6620RHB 200
(1) 2/0-600 or (2) #6-250 TMPAL30
T MP 3 8 6 20 T R F
GE Identification
Special
MEG Approved
Type
MP = Meter Mod Ring Type
Enclosures
MPR = Meter Mod Ringless
R = Type 3R rainproof
MPK = Meter Mod K-Base Socket
T MP 3 SB 8 R AR
GE Identification Additional Features
AR = Arc Reduction (For 1200A and greater
Type Main Breaker Type Main Modules only)
MP = Meter Mod III
CRIS = Copper, Riser
Product Features
UL Listed (details below)
Short Circuit Ratings through 100,000 Amps RMS symmetrical
Interchangeable Single and Three-phase Main and Meter Modules
Indoor/Outdoor Construction
Individual Meter Covers
11-inch Mounting Z-Rails Included
Numerous Accessories
Series Ratings 400A-2000A 1PH (2P) Main Breakers to 2-Pole THQL/THHQL (70-125A) - 125A Sockets1
Meter Mod III Meter Mod III Main Series Rating Voltage Voltage of Approved For
Main Breaker Section Breaker Frame Phase of Main (AIC) of Main Tenant Modular Metering
TMPSB4R SGH 400 65,000
TMPSHB4R SGL 400 100,000
TMPSB6R SGH 600 65,000
TMPSHB6R SGL 600 1 100,000 208/120 Vac 120/240 Vac Yes
TMPSB8R SKH 800 65,000
TMPSB10R SKH 1000 65,000
TMPSB12R SKH 1200 65,000
TMPBB14R, TMPBT14R, TMPBB16R,
TMPBB16RST, TMPBT16R, TMPBT16RST, RGH 1 100,000 208/120 Vac 120/240 Vac No
TMPBT20R, TMPBB20R
1Does not include 60A THQL/THHQL Tenant Breaker (Use 70A Instead)
Series Ratings 400A-2000A 3PH (3P) Main Breakers to 2-Pole THQL/THHQL (70-125A) - 125A Sockets1
Meter Mod III Meter Mod III Main Series Rating Voltage Voltage of Approved For
Main Breaker Section Breaker Frame Phase of Main (AIC) of Main Tenant Modular Metering
TMP3SB4R SGH 400 65,000
TMP3SHB4R SGL 400 100,000
TMP3SB6R SGH 600 65,000
TMP3SHB6R SGL 600 3 100,000 208/120 Vac 120/240 Vac Yes
TMP3SB8R SKH 800 65,000
TMP3SB10R SKH 1000 65,000
TMP3SB12R SKH 1200 65,000
TMPBB14R, TMPBT14R, TMPBB16R,
TMPBB16RST, TMPBT16R, TMPBT16RST, RGH 3 100,000 208/120 Vac 120/240 Vac No
TMPBT20R, TMPBB20R
1Does not include 60A THQL/THHQL Tenant Breaker (Use 70A Instead)
Series Ratings 400A-2000A 1PH (2P) Main Fusible Switches to 2-Pole THQL/THHQL (70-125A) - 125A Sockets
Meter Mod III Main Meter Mod III Main Series Rating Voltage Voltage of Approved For
Fusible Switch Section Fuse Type Phase of Main (AIC) of Main Tenant Modular Metering
TMPFT4R T Fuse
TMPFB4R T Fuse
1 100,000 208/120 Vac 120/240 Vac Yes3
TMPFT6R T Fuse
TMPFB6R T Fuse
TMPFT8R T Fuse
TMPFB8R2 T or L Fuse
TMPFT12R2 T or L Fuse 1 100,000 208/120 Vac 120/240 Vac No
TMPFB12R2 T or L Fuse
TMPFB12RT T Fuse
2Field convertible to Class L fusing, no kit required
3Switches up to 600A rated for series rating at 42K and below; switches up to 400A rated for series rating from >42K 100K.
Series Ratings 400A-2000A 3PH (3P) Main Fusible Switches to 2-Pole THQL/THHQL (70-125A) - 125A Sockets
Meter Mod III Main Meter Mod III Main Series Rating Voltage Voltage of Approved For
Fusible Switch Section Fuse Type Phase of Main (AIC) of Main Tenant Modular Metering
TMP3FT4R T Fuse
TMP3FB4R T Fuse
3 100,000 208/120 Vac 120/240 Vac Yes3
TMP3FT6R T Fuse
TMP3FB6R T Fuse
TMP3FT8R2 T Fuse
TMP3FB8R T or L Fuse
TMP3FT12R2 T or L Fuse
3 100,000 208/120 Vac 120/240 Vac No
TMP3FB12R T or L Fuse
TMP3FB12RT T Fuse
TMP3FB12RST T or L Fuse
TMP3FT16R, TMP3FB16R, TMP3FB16RST,
L Fuse 3 100,000 208/120 Vac 120/240 Vac No
TMP3FT20R, TMP3FB20R, TMP3FB20RST
2Field convertible to Class L fusing, no kit required
3Switches up to 600A rated for series rating at 42K and below; switches up to 400A rated for series rating from >42K 100K.
Series Ratings 400A-2000A 1PH (2P) Main Breakers to 2-Pole TQD (100-200A) - 200A Sockets
Meter Mod III Meter Mod III Main Series Rating Voltage Voltage of Approved For
Main Breaker Section Breaker Frame Phase of Main (AIC) of Main Tenant Modular Metering
TMPSB4R SGH 400 65,000 Yes
TMPSHB4R SGL 400 100,000 No
TMPSB6R SGH 600 65,000 Yes
TMPSHB6R SGL 600 1 100,000 208/120 Vac 120/240 Vac No
TMPSB8R SKH 800 65,000 No
TMPSB10R SKH 1000 65,000 No
TMPSB12R SKH 1200 65,000 No
TMPBB14R, TMPBT14R, TMPBB16R,
TMPBB16RST, TMPBT16R, TMPBT16RST, RGH 1 100,000 208/120 Vac 120/240 Vac No
TMPBT20R, TMPBB20R
Series Ratings 400A-2000A 3PH (3P) Main Breakers to 2-Pole TQD (100-200A) - 200A Sockets
Meter Mod III Meter Mod III Main Series Rating Voltage Voltage of Approved For
Main Breaker Section Breaker Frame Phase of Main (AIC) of Main Tenant Modular Metering
TMP3SB4R SGH 400 65,000 Yes
TMP3SHB4R SGL 400 100,000 No
TMP3SB6R SGH 600 65,000 Yes
TMP3SHB6R SGL 600 3 100,000 208/120 Vac 120/240 Vac No
TMP3SB8R SKH 800 65,000 No
TMP3SB10R SKH 1000 65,000 No
TMP3SB12R SKH 1200 65,000 No
TMPBB14R, TMPBT14R, TMPBB16R,
TMPBB16RST, TMPBT16R, TMPBT16RST, RGH 3 100,000 208/120 Vac 120/240 Vac No
TMPBT20R, TMPBB20R
Series Ratings 400A-2000A 1PH (2P) Main Fusible Switches to 2-Pole TQD (100-200A) - 200A Sockets
Meter Mod III Main Meter Mod III Main Series Rating Voltage Voltage of Approved For
Fusible Switch Section Fuse Type Phase of Main (AIC) of Main Tenant Modular Metering
TMPFT4R T Fuse
TMPFB4R T Fuse
1 100,000 208/120 Vac 120/240 Vac Yes1
TMPFT6R T Fuse
TMPFB6R T Fuse
TMPFT8R T Fuse
TMPFB8R T or L Fuse
TMPFT12R L Fuse 1 100,000 208/120 Vac 120/240 Vac No
TMPFB12R L Fuse
TMPFB12RT T Fuse
1Switches up to 600A rated for series rating at 42K and below; switches up to 400A rated for series rating from >42K 100K.
Series Ratings 400A-2000A 3PH (3P) Main Fusible Switches to 2-Pole TQD (100-200A) - 200A Sockets
Meter Mod III Main Meter Mod III Main Series Rating Voltage Voltage of Approved For
Fusible Switch Section Fuse Type Phase of Main (AIC) of Main Tenant Modular Metering
TMP3FT4R T Fuse
TMP3FB4R T Fuse
3 100,000 208/120 Vac 120/240 Vac Yes1
TMP3FT6R T Fuse
TMP3FB6R T Fuse
TMP3FT8R T Fuse
TMP3FB8R T or L Fuse
TMP3FT12R L Fuse
3 100,000 208/120 Vac 120/240 Vac No
TMP3FB12R L Fuse
TMP3FB12RT T Fuse
TMP3FB12RST T or L Fuse
TMP3FT16R, TMP3FB16R, TMP3FB16RST,
L Fuse 3 100,000 208/120 Vac 120/240 Vac No
TMP3FT20R, TMP3FB20R, TMP3FB20RST
1Switches up to 600A rated for series rating at 42K and below; switches up to 400A rated for series rating from >42K 100K.
TMPSB4R
Main Breaker Single-Phase, Three-Wire 120/240 Vac
Breaker included, top or bottom feed. 80% Rated MCB.
Main Main Wire Size Product
Ampere Rating IC Rating (Max) Main Wire Size AWG/kcmil Cu/Al - Phase AWG/kcmil Cu/Al - Neutral Number
400 65 kAIC Al :(2) 2/0 - 500 or (1) 6 -600 Cu 2/0 - 400 or (1) 6 -600 (2) 2 -600 TMPSB4R
400 100 kAIC Al :(2) 2/0 - 500 or (1) 6 -600 Cu 2/0 - 400 or (1) 6 -600 (2) 2 -600 TMPSHB4R
600 65 kAIC Al :(2) 2/0 - 500 or (1) 6 -600 Cu 2/0 - 400 or (1) 6 -600 (2) 2 -600 TMPSB6R
600 100 kAIC Al :(2) 2/0 - 500 or (1) 6 -600 Cu 2/0 - 400 or (1) 6 -600 (2) 2 -600 TMPSHB6R
800 65 kAIC Al/Cu (3) 3/0 -5001 (4) 250-5002 TMPSB8R
1000 65 kAIC Al(4) 250-500 CU(4) 250/3501 (4) 250-5002 TMPSB10R
1200 65 kAIC Al(4) 250-500 CU(4) 250/3501 (4) 250-5002 TMPSB12R7
1400 100 kAIC (4) 500-1000 kcmil Al/Cu (4) 500-1000 TMPBB14R4,6
1400 100 kAIC (4) 500-1000 kcmil Al/Cu (4) 500-1000 TMPBT14R5,6
1600 100 kAIC Al/Cu (4) 500-1000 kcmil Al/Cu (4) 500-1000 TMPBB16R4,6
1600 100 kAIC Al/Cu (4) 500-1000 kcmil Al/Cu (4) 500-1000 TMPBB16RST3,4,6
1600 100 kAIC Al/Cu (4) 500-1000 kcmil Al/Cu (4) 500-1000 TMPBT16R5,6
1600 100 kAIC Al/Cu (4) 500-1000 kcmil Al/Cu (4) 500-1000 TMPBT16RST3,5,6
2000 100 kAIC (6) #2 600 kcmil (6) #2 600 kcmil TMPBT20R5,6
2000 100 kAIC (6) #2 600 kcmil (6) #2 600 kcmil TMPBB20R4,6
Main Breaker Single-Phase, Three-Wire 120/240 Vac with Arc Reduction Means
The main breaker in this section has an arc reduction means that satisfies the requirement of NEC 2014 Section 240.87
Main Main Wire Size Product
Ampere Rating IC Rating (Max) Feed Main Wire Size AWG/kcmil Cu/Al - Phase AWG/kcmil Cu/Al - Neutral Number
Use Standard Part #.
400 to less than 1200 Top or Bottom Code effects only 1200A
and greater
Use 1400 or 1600A and advise GE
1200 Top or Bottom
sales rep to make trip unit 1200A
1400 100 kAIC Bottom (4) 500-1000 (4) 250-500 TMPBB14RAR
Bottom TMPBB16RAR
1600 100 kAIC (4) 500-1000 (4) 500-1000
Top TMPBT16RAR
2000 100 kAIC Bottom (6) #2-600 (6) #2-600 TMPBB20RAR
NOTE: These main sections use type RG Breakers. These breakers no longer have rating plugs; they have factory installed trip units. If
you need a trip setting that is different than the frame (For example, if you need a TMPBB16RAR 1600A frame with a 1200A trip), please
inform your GE sales rep at time of order entry. A request will be made to have this manually changed at the factory.
1Optional lug TCAL124 field installed wire range (3) 300-750 kcmil.
2Optional neutral lug field installed wire range (3) 1/0-750 kcmil.
Lug kit part number TMPL750.
3Includes 110-240 Vac shunt trip.
4Bottom feed.
5Top feed.
6Fixed Rating Plug not Field adjustable.
7To meet NEC 2014 Arc Energy Reduction (Section 240.87), please use a 1175A
rating plug. Product Number SRPK1200A1175, order separately.
Main Breaker Three-Phase, Four-Wire / Single-Phase, Three-Wire 120/240 Vac, 208Y/120 Vac
Breaker included, top or bottom feed. 80% Rated MCB
Main Main Wire Size Product
Ampere Rating IC Rating (Max) Main Wire Size AWG/kcmil Cu/Al - Phase AWG/kcmil Cu/Al - Neutral Number
400 65 kAIC Al :(2) 2/0 - 500 or (1) 6 -600 Cu 2/0 - 400 or (1) 6 -600 (2) 2 -600 TMP3SB4R
400 100 kAIC Al :(2) 2/0 - 500 or (1) 6 -600 Cu 2/0 - 400 or (1) 6 -600 (2) 2 -600 TMP3SHB4R
600 65 kAIC Al :(2) 2/0 - 500 or (1) 6 -600 Cu 2/0 - 400 or (1) 6 -600 (2) 2 -600 TMP3SB6R
600 100 kAIC Al :(2) 2/0 - 500 or (1) 6 -600 Cu 2/0 - 400 or (1) 6 -600 (2) 2 -600 TMP3SHB6R
800 65 kAIC Al/Cu (3) 3/0 -5001 (4) 250-5002 TMP3SB8R
1000 65 kAIC Al(4) 250-500 Cu(4) 250/3501 (4) 250-5002 TMP3SB10R
1200 65 kAIC Al(4) 250-500 Cu(4) 250/3501 (4) 250-5002 TMP3SB12R9
1400 100 kAIC (4) 500-1000 kmcil (4) 500-1000 kmcil TMP3BB14R4,7
1400 100 kAIC (4) 500-1000 kmcil (4) 500-1000 kmcil TMP3BT14R5,7
1600 100 kAIC Al/Cu (4) 500-1000 Al/Cu (4) 500-1000 TMP3BB16R4,7
1600 100 kAIC Compression Lugs Compression Lugs TMP3BB16RCLL4,7
1600 100 kAIC Al/Cu (4) 500-1000 Al/Cu (4) 500-1000 TMP3BB16RST3,4,7
1600 100 kAIC Al/Cu (4) 500-1000 Al/Cu (4) 500-1000 TMP3BT16R5,7
1600 100 kAIC Al/Cu (4) 500-1000 Al/Cu (4) 500-1000 TMP3BT16RST3.5.7
2000 100 kAIC (6) #2-600 kcmil (6) #2-600 kcmil TMP3BT20R5,7
2000 100 kAIC (6) #2-600 kcmil (6) #2-600 kcmil TMP3BB20R4,7
2000 100 kAIC Compression Lugs Compression Lugs TMP3BB20RCLL4,7
2000 100 kAIC (6) #2-600 kcmil (6) #2-600 kcmil TMP3BT20RST3,5,7
2000 100 kAIC (6) #2-600 kcmil (6) #2-600 kcmil TMP3BB20RST3,4,7
Main Breaker Three-Phase, Four-Wire 208Y/120 Vac or Three-Phase, Four-Wire 120/240 Vac,
Delta Hi-Leg with Arc Reduction Means
The main breaker in this section has an arc reduction means that satisfies the requirement of NEC 2014 Section 240.87
Main Main Wire Size Product
Ampere Rating IC Rating (Max) Feed Main Wire Size AWG/kcmil Cu/Al - Phase AWG/kcmil Cu/Al - Neutral Number
Use Standard Part #.
400 to less than 1200 Top or Bottom Code effects only 1200A
and greater
Use 1400 or 1600A and advise GE
1200 Top or Bottom
sales rep to make trip unit 1200A
Bottom TMP3BB14RAR
1400 100 kAIC (4) 500-1000 (4) 500-1000
Top TMP3BT14RAR
Bottom TMP3BB16RAR
1600 100 kAIC (4) 500-1000 (4) 500-1000
Top TMP3BT16RAR
Top TMP3BT20RAR
2000 100 kAIC (6) #2-600 (6) #2-600
Bottom TMP3BB20RAR
NOTE: These main sections use type RG Breakers. These breakers no longer have rating plugs; they have factory installed trip units. If
you need a trip setting that is different than the frame (For example, if you need a TMP3BB16RAR 1600A frame with a 1200A trip),
please inform your GE sales rep at time of order entry. A request will be made to have this manually changed at the factory.
Main Breaker Modules Shunt-Trip - Field Installed
Alternate Rating Plugs Field Installed8 For Use on all Main Breaker Modules
Product Product
Main Ampere Rating Alternate Rating Number Shunt Trip Number
TMPFB6R
Main Fusible Switch Three-Phase, Four-Wire / Single-Phase, Three-Wire 120/240 Vac, 208Y/120 Vac, 240/120 Vac
T-Fuses not included (available from table on page 2-18).
Main Main Wire Size Main Wire Size Stud sets
Ampere IC Rating AWG/kcmil AWG/kcmil per Phase Compression Product
Wire Entry Rating (Max) Cu/Al - Phase Cu/Al - Neutral and Neutral Lug Landing Kit2 Number
Top 400 100 kAIC (1) 1/0-750 or (2) 1/0 -300 (1) 1/0-750 or (2) 1/0 -300 1 Order Separately TMP3FT4R1
Top 600 100 kAIC (2) 2- 600 (2) 2- 600 1 Order Separately TMP3FT6R1
Top 800 100 kAIC (4) 3/0-750 (4) 3/0-750 1 Order Separately TMP3FT8R1
Top 1200 100 kAIC (4) 4-600 (4) 4-600 TMP3FT12R2
Top 1600 100 kAIC (6) 4-600 (6) 4-600 TMP3FT16R2
Top 2000 100 kAIC (8) 4-600 (8) 4-600 TMP3FT20R2
Bottom 400 100 kAIC (1) 1/0-750 or (2) 1/0 -300 (1) 1/0-750 or (2) 1/0 -300 1 Order Separately TMP3FB4R1
Bottom 600 100 kAIC (2) 2- 600 (2) 2- 600 1 Order Separately TMP3FB6R1
Bottom 800 100 kAIC (4) 3/0-750 (4) 3/0-750 1 Order Separately TMP3FB8R1
Bottom 1200 100 kAIC (4) 2-600 (4) 2-600 TMP3FB12RT5
Bottom 1200 100 kAIC (4) 4-600 (4) 4-600 TMP3FB12R6
Bottom 1600 100 kAIC (6) 4-600 (6) 4-600 TMP3FB16R2
Bottom 2000 100 kAIC (8) 4-600 (8) 4-600 TMP3FB20R2
Bottom 1200 100 kAIC (4) 4-600 (4) 4-600 TMP3FB12RST2,7
Bottom 1600 100 kAIC (6) 4-600 (6) 4-600 TMP3FB16RST2,7
Bottom 2000 100 kAIC (8) 4-600 (8) 4-600 TMP3FB20RST2,7
1Class T fuse only.
2Class L fuse only. Bolted pressure switch.
3TMPFB12RT is a standard fusible switch that uses only Class T fuses. This unit is less robust and smaller than the TMPFB12R, but is significantly less expensive.
4TMPFB12R is a bolted pressure switch that uses only Class L fuses. This unit is larger and more robust than the TMPFB12RT, but more expensive.
5TMP3FB12RT is a standard fusible switch that uses only Class T fuses. This unit is less robust and smaller than the TMP3FB12R, but is significantly less expensive.
6TMP3FB12R is a bolted pressure switch that uses only Class L fuses. This unit is larger and more robust than the TMP3FB12RT, but more expensive.
7Product numbers ending in ST have shunt tripping style bolted pressure switch.
TMP3L6R
Main Fusible Switch w/Integral Pull Box Single-Phase, Three-Wire 120/240 Vac
End or center mounting. Lugs not included. Meets EUSERC requirements. When meter stacks are to be mounted on handle side of
switch order TMPS12 spacer. All modules accept Class T fuse.
Main IC Rating Main Wire Size Main Wire Size Compression Lug Product
Wire Entry Ampere Rating (Max) AWG/kcmil Cu/Al - Phase AWG/kcmil Cu/Al - Neutral Landing Kit Number
Bottom 400 100 kAIC Compression Lug Landing Kit Included Compression Lug Landing Kit Included Included TMPFB4RCLL
(NEMA 2-Hole Spacing) (NEMA 2-Hole Spacing)
Bottom 600 100 kAIC Compression Lug Landing Kit Included Compression Lug Landing Kit Included Included TMPFB6RCLL
(NEMA 2-Hole Spacing) (NEMA 2-Hole Spacing)
Bottom 800 100 kAIC Compression Lug Landing Kit Included Compression Lug Landing Kit Included Included TMPFB8RCLL
(NEMA 2-Hole Spacing) (NEMA 2-Hole Spacing)
Bottom 12001 100 kAIC Compression Lug Landing Kit Included Compression Lug Landing Kit Included Included TMPFB12RCLLT
(NEMA 2-Hole Spacing) (NEMA 2-Hole Spacing)
Main Fusible Switch w/Integral Pull Box Three-Phase, Four-Wire / Single-Phase, Three-Wire 120/240 Vac, 208Y/120 Vac, 240/120 Vac
End or center mounting. Lugs not included. Meets EUSERC requirements. When meter stacks are to be mounted on handle side of
switch, order TMPS12 spacer. All modules accept Class T fuse.
Main IC Rating Main Wire Size Main Wire Size Compression Lug Product
Wire Entry Ampere Rating (Max) AWG/kcmil Cu/Al - Phase AWG/kcmil Cu/Al - Neutral Landing Kit Number
Bottom 400 100 kAIC Compression Lug Landing Kit Included Compression Lug Landing Kit Included Included TMP3FB4RCLL
(NEMA 2-Hole Spacing) (NEMA 2-Hole Spacing)
Bottom 600 100 kAIC Compression Lug Landing Kit Included Compression Lug Landing Kit Included Included TMP3FB6RCLL
(NEMA 2-Hole Spacing) (NEMA 2-Hole Spacing)
Bottom 800 100 kAIC Compression Lug Landing Kit Included Compression Lug Landing Kit Included Included TMP3FB8RCLL
(NEMA 2-Hole Spacing) (NEMA 2-Hole Spacing)
Bottom 1200 100 kAIC Compression Lug Landing Kit Included Compression Lug Landing Kit Included Included TMP3FB12RCLLT
(NEMA 2-Hole Spacing) (NEMA 2-Hole Spacing)
Main Lug Three-Phase, Four-Wire / Single-Phase, Three-Wire 120/240 Vac, 208Y/120 Vac
End or center mounting. Lugs included.
Main IC Rating2 Main Wire Size Main Wire Size Stud sets per Phase Compression Lug Product
Wire Entry Ampere Rating (Max) AWG/kcmil Cu/Al - Phase AWG/kcmil Cu/Al - Neutral and Neutral Landing Kit Number
Bottom/Top 400 100 kAIC (1) 6-600 or (2) 1/0-250 (1) 6-600 or (2) 1/0-250 1 Order Separately TMP3L4R
Bottom/Top 400 100 kAIC (1) 6-600 or (2) 1/0-250 (1) 6-600 or (2) 1/0-250 1 Order Separately TMP3L4RCU3
Bottom/Top 600 100 kAIC (2) 250-500 (2) 250-500 1 Order Separately TMP3L6R
Bottom/Top 600 100 kAIC (2) 250-500 (2) 250-500 1 Order Separately TMP3L6RCU3
Bottom/Top 800 100 kAIC (2) 1/0-750 or (4) 1/0-300 (2) 1/0-750 or (4) 1/0 -300 2 Order Separately TMP3L8R
Bottom/Top 800 100 kAIC (2) 1/0-750 or (4) 1/0-300 (2) 1/0-750 or (4) 1/0 -300 2 Order Separately TMP3L8RCU3
Bottom/Top 1200 100 kAIC (3) 1/0-750 or (6) 1/0-300 (3) 1/0-750 or (6) 1/0 -300 2 Order Separately TMP3L12R
Bottom/Top 1600 100 kAIC (6) 250-500 (6) 250-500 2 Order Separately TMP3L16R
Main Lug with Feed Through, Three Phase, Four Wire / Single Phase, Three Wire 120/240 Vac, 208Y/120 Vac
Main IC Rating Stud sets per Phase Compression Lug Product
Wire Entry Ampere Rating (Max) Incoming Line Outgoing Load and Neutral Landing Kit Number
Bottom/Top 1200 100 kAIC (5) Up to 750 MCM (5) Up to 750 MCM 2 TMP3L12RCRIS
per Phase/Neutral (AL/CU) per Phase/Neutral (AL/CU)
Bottom/Top 1600 100 kAIC (5) Up to 750 MCM (5) Up to 750 MCM 2 TMP3L16RCRIS
per Phase/Neutral (AL/CU) per Phase/Neutral (AL/CU)
1Center-feed only for single-phase meter modules with 800A horizontal bus rating.
2Limited to the lowest marked short circuit rating of the main and meter modules used.
3Copper bus.
TMPU4R
Main Pull Box Three-Phase, Four-Wire / Single-Phase, Three-Wire 120/240 Vac, 208Y/120 Vac, 240/120 Vac
End or center mounting. Lugs only included; cross bus not included.
Main Main Wire Size Main Wire Size Stud sets
Ampere IC Rating1 AWG/kcmil AWG/kcmil per Phase Compression Lug Product
Wire Entry Rating (Max) Cu/Al - Phase Cu/Al - NeutraL and Neutral Landing Kit Number
Bottom/Top 400 100 kAIC (1) 1/0-750 or (1) 1/0-750 or 1 Included TMP3U4R
(2) 1/0-300 (Load) (2) 1/0 -300 (Load)
Bottom/Top 800 100 kAIC (2) 1/0-750 or (2) 1/0-750 or 2 Included TMP3U8R
(4) 1/0-300 (Load) (4) 1/0-300 (Load)
Bottom/Top 1200 100 kAIC (4) 2-600 (Load) (4) 2-600 (Load) 3 Included TMP3U12R
1Limited to the lowest marked short circuit rating of the main and meter modules used.
TMP8512R TMPR8220R
Ring Type Socket - 800A Horizontal Bussing Ring-Type Socket - 1200A Horizontal Bussing
No. of Standard MEG No. of Standard MEG
Socket Amps Sockets Product Number Product Number2 Socket Amps Sockets Product Number Product Number2
125A 2 TMP8212R TMP8212RF 125A 2 TMP12212R TMP12212RF
125A 3 TMP8312R TMP8312RF 125A 3 TMP12312R TMP12312RF
125A 4 TMP8412R TMP8412RF 125A 4 TMP12412R TMP12412RF
125A 5 TMP8512R TMP8512RF 125A 5 TMP12512R TMP12512RF
125A 6 TMP8612R TMP8612RF 125A 6 TMP12612R TMP12612RF
200A 2 TMP8220R Use TMP8320RF 200A 2 TMP12220R TMP12220RF
200A 3 TMP8320R TMP8320RF 200A 3 TMP12320R TMP12320RF
200A 4 TMP8420R TMP8420RF 200A 4 TMP12420R TMP12420RF
200A 5 TMP8520R Use two smaller sections 200A 5 TMP12520R TMP12520RF
200A 5 TMP8520RBUS3 Use two smaller sections 200A 5 TMP12520RBUS3 Use TMP12520RF
Ringless Type Socket - 800A Horizontal Bussing Ringless Type Socket - 1200A Horizontal Bussing
(Includes 5th Jaw Standard) (Includes 5th Jaw Standard)
Standard MEG MEG & Standard MEG MEG &
Socket No. of Product Product Horned Bypass Horned Bypass
Socket No. of Product Product Horned Bypass Horned Bypass
Amps Sockets Number Number2 Product Number1 Product Number2
Amps Sockets Number Number2 Product Number1 Product Number2
TMPR12412RF+
125A 2 TMPR8212R TMPR8212RF TMPR8212RHB TMPR8212RHBF1 TMPR12412RF+
125A 2 TMPR12212R TMPR12212RHB (2) TMCB12B+
125A 3 TMPR8312R TMPR8312RF TMPR8312RHB TMPR8312RHBF1 (2) TMCB12B
(1) TMPBH20A
125A 4 TMPR8412R TMPR8412RF TMPR8412RHB TMPR8412RHBF1
TMPR12412RF+
Use TMPR8512RF+ TMPR12412RF+
125A 5 TMPR8512R TMPR8512RF TMPR8512RHB 125A 3 TMPR12312R TMPR12312RHB (1) TMCB12B+
TMBPH20A (1) TMCB12B
(1) TMPBH20A
Use TMPR8612RF+
125A 6 TMPR8612R TMPR8612RF TMPR8612RHB 125A 4 TMPR12412R TMPR12412RF TMPR12412RHB TMPR12412RHBF1
TMBPH20A
125A 5 TMPR12512R TMPR12512RF TMPR12512RHB TMPR12512RHBF1
Use TMPR8220RHB+
200A 2 TMPR8220R Use TMPR8320RF TMPR8220RHB TMPR12612RF+
TMBPH20A 125A 6 TMPR12612R TMPR12612RF TMPR12612RHB
TMBPH20A
Use TMPR8320RHB+
200A 3 TMPR8320R TMPR8320RF TMPR8320RHB TMPR12420RF+
TMBPH20A TMPR12420RF+
200A 2 TMPR12220R TMPR12220RHB (2) TMCB20B+
200A 4 TMPR8420R TMPR8420RF TMPR8420RHB TMPR8420RHBF1 (2) TMCB20B
(1) TMPBH20A
Use TMPR8520RHB+
200A 5 TMPR8520R TMPR8520RF TMPR8520RHB TMPR12420RF+
TMBPH20A TMPR12420RF+
200A 3 TMPR12320R TMPR12320RHB (1) TMCB20B+
Use TMPR8520RF+ (1) TMCB20B
200A 5 TMPR8520RBUS3 Use TMPR8520RF TMPR8520RHBBUS3 (1) TMPBH20A
TMBPH20A
200A 4 TMPR12420R TMPR12420RF TMPR12420RHB TMPR12420RHBF1
1Includes horn by-pass. TMPR12520RF+
2F units have an additional cotter pin that has been added to the meter socket 200A 5 TMPR12520R TMPR12520RF TMPR12520RHB
TMBPH20A
assembly that will keep the meter socket from detaching from the base. This Use TMPR12520RF+
change meets the new MEG requirements. 200A 5 TMPR12520RBUS3 Use TMPR12520RF TMPR12520RHBBUS3
TMBPH20A
3Parts with BUS on the end have the horizontal bussing centerline on the 3rd meter
rather than 2nd meter, making the unit shorter from the centerline for applications
where height of top meter may be an issue. Ring Type Socket Factory Phase Balanced (w/Copper Bus)
No. of Product
Socket Amps Sockets Number
125A 2 TMP8212RAB
125A 2 TMP8212RAC
125A 2 TMP8212RBC
125A 3 TMP8312RAB
125A 3 TMP8312RAC
125A 3 TMP8312RBC
125A 4 TMP8412RAB
125A 4 TMP8412RAC
125A 4 TMP8412RBC
TMZR
TMBR
Product Features
Single-Phase/Three-Wire, 120/240 Vac or Three-Phase,
Four-Wire, Horizontal Bus, 208Y/120 Vac System Voltage
UL listed
1200 amp, 4-wire cross bus (aluminum)
Front Accessible Field Phase Balancing by Meter Socket
(1) 14-2 Equipment Ground per Socket, Factory Installed
Only 225A and 400 Ringless Type meter stacks, contain lever
bypass. 125A and 200A meter sockets do not contain lever
bypass
Ringless Type Socket w/ Lever Bypass
TMPR12122R
Product
Socket Amps No. of Sockets Number
225A 1 TMPR12122R1,5
225A 2 TMPR12222R1,5
Tenant Main Circuit Breakers 100,000 AIC
225A 3 TMPR12322R1,5 Wire Size Product
225A 4 TMPR12422R1,5 Socket Amps Ampere Rating Load Lugs Number
400A 1 TMPR12140RB1,2,9
400A 2 TMPR12240RB1,3,9 200 60 (1) #6-1/0 CU; # 6-1/0 AL TMQD22060
400A 1 TMPK12140RB1 200 70 (1) #6-1/0 CU; # 6-1/0 AL TMQD22070
400A 1 TMPK12140RBA1 200 80 (1) #6-1/0 CU; # 6-1/0 AL TMQD22080
200 90 (1) #6-1/0 CU; # 6-1/0 AL TMQD22090
Ring Type Socket 200 100 (1) #6-4/0 CU; #6-4/0 AL TMQD22100
200 125 (1) #6-4/0 CU; #6-4/0 AL TMQD22125
Product 200 150 (1) #6-4/0 CU; #6-4/0 AL TMQD22150
Socket Amps No. of Sockets Number 200 175 (1) #6-4/0 CU; #6-4/0 AL TMQD22175
225A 1 TMP8120RTAB4,5 200 200 (1) #6-4/0 CU; #6-4/0 AL TMQD22200
225A 1 TMP8120RTBC4,5
225A 1 TMP8120RTAC4,5
225A 2 TMP112220RTAB4,5 Accessories Field Installed
225A 2 TMP112220RTAC4,5 Product
225A 2 TMP112220RTBC4,5 Type Description Number
225A 3 TMP112320RTAB4,5
225A 3 TMP112320RTAC4,5 TEB Breaker TMTEB
225A 3 TMP112320RTBC4,5 Mounting Kit
Barrel Lock Bracket TMBL6
One snap-type, aluminum sealing ring (TSR5) per socket included. and Guard Kit
Bypass Kit Totalizing Jumper Type TMBPT3206,7
Tenant Main Circuit Breakers 10,000 AIC Blank Meter
Socket Cover Fits all positions TMCB322A
Wire Size Product Individual Meter TMBR3
Socket Amps Ampere Rating Load Lugs Number
Socket Barrier Kit (Includes 6)
225 15 (1) #14-3 CU; #12-1 AL TEB122015 Insulator for Lever TMHN
225 20 (1) #14-3 CU; #12-1 AL TEB122020 By-pass Handle
225 25 (1) #14-3 CU; #12-1 AL TEB122025 Mounting Z Rail 4-foot TMZR
225 30 (1) #14-3 CU; #12-1 AL TEB122030 Spacer 4 inch, TMPS12
225 35 (1) #14-3 CU; #12-1 AL TEB122035 4 cross bus rated, 1200A
225 40 (1) #14-3 CU; #12-1 AL TEB122040
Elbow 16 inch x 16 inch, TMPE128
225 45 (1) #14-3 CU; #12-1 AL TEB122045
225 50 (1) #14-3 CU; #12-1 AL TEB122050 4 cross bus rated 1200A
225 60 (1) #14-3 CU; #12-1 AL TEB122060 Elbow 12 inch x 12 inch, TMPE12A8
225 70 (1) #14-3 CU; #12-1 AL TEB122070 4 cross bus rated 1200A
225 80 (1) #14-3 CU; #12-1 AL TEB122080 1Only 225A and 400A are lever bypass.
225 90 (1) #14-3 CU; #12-1 AL TEB122090 2One 400A tenant breaker included.
225 100 (1) #14-3 CU; #12-1 AL TEB122100
3Two 400A tenant breakers included.
225 125 (1) #1-300 CU; #1-300 AL TQD22125
225 150 (1) #1-300 CU; #1-300 AL TQD22150 4Meets EUSERC requirements. T- suffix signifies test bypass kit. Suffixes AB, BC, AC
225 175 (1) #1-300 CU; #1-300 AL TQD22175 reflect the factory-set phase balancing.
225 200 (1) #1-300 CU; #1-300 AL TQD22200 5Included factory-installed fifth jaw (TM5JA Bused).
6Not UL listed.
Tenant Main Circuit Breakers 22,000 AIC 7180 amps continuous.
8Indoor, Type 1.
Wire Size Product
9See Page 2-12 for alternate 400A Rating Plugs
Socket Amps Ampere Rating Load Lugs Number
200 100 (1) #1-300 CU; #1-300 AL THQD22100
200 125 (1) #1-300 CU; #1-300 AL THQD22125
200 150 (1) #1-300 CU; #1-300 AL THQD22150
200 175 (1) #1-300 CU; #1-300 AL THQD22175
200 200 (1) #1-300 CU; #1-300 AL THQD22200
Product Features
Three-Phase/Four-Wire, 240-120 Vac; Three-Phase/Four-Wire,
208Y/120 Vac
UL listed
1200 amp, 4-wire cross bus (aluminum)
Front Accessible Field Phase Balancing by Meter Socket
(1) 14-2 Equipment Ground per Socket, Factory Installed
Swingaway Mounting Feet Factory Installed
Only 225A and 400A sockets, Ringless Type, contain lever
bypass. 125A + 200A meter sockets do not contain lever bypass.
TMPR312140RB
Ringless Type Socket w/Lever Bypass. All units are 7-terminal Tenant Main Circuit Breakers 22,000 AIC
except TMPK. Wire Size Product
Socket Amps Ampere Rating Load Lugs Number
Product
Socket Amps No. of Sockets Number 225/400/200 100 (1) #1-300 CU; #1-300 AL THQD32100
225/400/200 125 (1) #1-300 CU;#1-300 AL THQD32125
225A 1 TMPR312122R8
225/400/200 150 (1) #1-300 CU; #1-300 AL THQD32150
225A 2 TMPR312222R8
225/400/200 175 (1) #1-300 CU; #1-300 AL THQD32175
225A 3 TMPR312322R8
225/400/200 200 (1) #1-300 CU; #1-300 AL THQD32200
225A 4 TMPR312422R8
225/400/200 225 Use TMQD
400A 1 TMPR312140TR1,8
400A 1 TMPR312140RB2,8
400A 2 TMPR312240RB3,8
Tenant Main Circuit Breakers 100,000 AIC
400A 1 TMPK312140RB Wire Size Product
400A 1 TMPK312140RBA Socket Amps Ampere Rating Load Lugs Number
225/400/200 60 (1) #6-1/0 CU; #6-1/0 AL TMQD32060
Ring Type Socket 7-terminal units 225/400/200 70 (1) #6-1/0 CU; #6-1/0 AL TMQD32070
Product 225/400/200 80 (1) #6-1/0 CU; #6-1/0 AL TMQD32080
Socket Amps No. of Sockets Number 225/400/200 90 (1) #6-1/0 CU; #6-1/0 AL TMQD32090
225/400/200 100 (1) #6-4/0 CU; #6-4/0 AL TMQD32100
200A 1 TMP38120RT4,8
225/400/200 125 (1) #6-4/0 CU; #6-4/0 AL TMQD32125
200 A 2 TMP312220RT4,8
225/400/200 150 (1) #6-4/0 CU; #6-4/0 AL TMQD32150
200A 3 TMP312320RT4,8
225/400/200 175 (1) #1/0-300 CU; 1/0-300 AL TMQD32175
225/400/200 200 (1) #1/0-300 CU; 1/0-300 AL TMQD32200
Tenant Main Circuit Breakers 10,000 AIC 225/400/200 225 (1) #1/0-300 CU; 1/0-300 AL TMQD32225
Wire Size Product
Socket Amps Ampere Rating Load Lugs Number Accessories Field Installed
225/400/200 15 (1) #14-3 CU; #12-1 AL TEB132015 Product
225/400/200 20 (1) #14-3 CU; #12-1 AL TEB132020 Type Description Number
225/400/200 25 (1) #14-3 CU; #12-1 AL TEB132025
TEB Breaker TMTEB
225/400/200 39 (1) #14-3 CU; #12-1 AL TEB132030
Mounting Kit
225/400/200 35 (1) #14-3 CU; #12-1 AL TEB132035
Barrel Lock Bracket TMBL5
225/400/200 40 (1) #14-3 CU; #12-1 AL TEB132040
and Guard Kit
225/400/200 45 (1) #14-3 CU; #12-1 AL TEB132045
Bypass Kit Totalizing Jumper Type TMBPT3205,6
225/400/200 50 (1) #14-3 CU; #12-1 AL TEB132050
Replacement TMPJ315
225/400/200 60 (1) #14-3 CU; #12-1 AL TEB132060
Phase Balancing
225/400/200 70 (1) #6-2/0 CU; #4-2/0 AL TEB132070
Jumper Kit
225/400/200 80 (1) #6-2/0 CU; #4-2/0 AL TEB132080
Blank Meter
225/400/200 90 (1) #6-2/0 CU; #4-2/0 AL TEB132090
Socket Cover Fits all positions TMCB322A
225/400/200 100 (1) #6-2/0 CU; #4-2/0 AL TEB132100
Individual Meter TMBR3
225/400/200 125 (1) #1-300 CU; #1-300 AL TQD32125
Socket Barrier Kit (Includes 6)
225/400/200 150 (1) #1-300 CU; #1-300 AL TQD32150
Insulator for Lever TMHN
225/400/200 175 (1) #1-300 CU; #1-300 AL TQD32175
By-pass Handle
225/400/200 200 (1) #1-300 CU; #1-300 AL TQD32200
Mounting Z Rail 4-foot TMZR
225/400/200 225 Use TMQD
Spacer 4 inch, TMPS12
4 cross bus rated, 1200A
Elbow 16 inch x 16 inch, TMPE127
4 cross bus rated 1200A
Elbow 12 inch x 12 inch, TMPE12A7
4 cross bus rated 1200A
1Requires two tenant main breakers, 400 amp maximum sum of branch ratings.
Cannot be used to serve a single 400A load.
2400 Amp tenant breaker included, 65 kAIC.
3Two 400 Amp tenant breakers included.
4Meets EUSERC requirements. T suffix indicates EUSERC test bypass kit included.
5Not UL listed.
6180 amps continuous.
7Indoor, Type 1, for inside corners only.
8These product numbers are shipped from the factory as 7-jaw units (7-terminal).
N N N N
All three-phase meter stack modules come fac-
tory connected to phase A and B, per Figure A. A A
A A A A
When connected to a 208Y/120 Vac 3-phase,
4-wire system, field phase balancing of two out
of every three stacks is required. One of every B B B B
C C C C
C
"Barrel" Shaped
Phase Connector C
FIELD 125A A-C PHASING "Z" Shaped
Remove "Z" Phase Connector from "B" Phase Phase Connector
Horizontal Bus FACTORY 200A A-C PHASING
Replace with "Barrel" Phase Connector supplied
Remove "Z" Phase Connector from "B" Phase
with meter stack and attach to "C" Phase Bus
Horizontal Bus
as shown.
Reattached at "C" Phase Horizontal Bus as Shown.
Torque to 60 lb-in (6.78 N-M)
Torque to 60 lb-in (6.78 N-M)
Retain "Z" Phase Connector for future use.
"Z" Shaped
Phase
Connector
Figure B
N N N N
A A A A
"Barrel" Shaped
Phase
Connector B B B B
C C C C C
Z Shaped and Barrel Shaped Phase B C B
Connectors
"Barrel" Shaped "Z" Shaped
Phase Connector Phase Connector
FIELD 125A C-B PHASING "Barrel" Shaped "Z" Shaped
Phase Connector Phase Connector
Remove "Barrel" Phase Connector from "A" Phase
Horizontal Bus FACTORY 200A C-B PHASING
Reattached at "C" Phase Horizontal Bus as shown. Remove "Barrel" Phase Connector from "A" Phase
Torque to 60 lb-in (6.78 N-M) Horizontal Bus
Reattached at "C" Phase Horizontal Bus as shown.
Torque to 60 lb-in (6.78 N-M)
Figure C
For applications where the main module ampere rating is greater than that of the meter stack horizontal bus, the main
module must be placed in the middle of the lineup (Figure A). The engineer of record must provide calculations on the
plans to show that the horizontal bussing will not be overloaded on either side. This situation, called Center-Feeding, can
happen in either 800A or 1200A horizontal bus meter stack applications, depending on the main ampere rating. Refer to
chart below for amperage and bus information. NOTE: Figure B shows the incorrect configurations.
Figure A Figure B
Dimensions
Product Width Height Depth Section A Section B
Description Number Figure No.1 (in inches) (in inches) (in inches) (in inches) (in inches)
Mini Mod, 1P3W, 200A MLO, (2) 125A Ring sockets TMM2212R, TMM2212RF 1 11.88 34.56 7.56 18.31 9.00
Mini Mod, 1P3W, 200A MLO, (2) 125A Ringless sockets TMMR2212R, TMMR2212RF, TMMR2212RHB 1 11.88 34.56 7.56 18.31 9.00
Mini Mod, 1P3W, 400A MLO, (3) 125A Ring sockets TMM4312R, TMM4312RF 3 24.25 48.31 7.00 21.56 9.00
Mini Mod, 1P3W, 400A MLO, (3) 125A Ringless sockets TMMR4312R, TMMR4312RF, TMMR4312RHB 3 24.25 48.31 7.00 21.56 9.00
Mini Mod, 1P3W, 400A MLO, (4) 125A Ring sockets TMM4412R, TMM4412RF 3 24.25 48.31 7.00 12.56 9.00
Mini Mod, 1P3W, 400A MLO, (4) 125A Ringless sockets TMMR4412R, TMMR4412RF, TMMR4412RHB 3 24.25 48.31 7.00 12.56 9.00
Mini Mod, 1P3W, 600A MLO, (5) 125A Ring sockets TMM6512R, TMM6512RF 2 36.28 41.59 7.00 12.56 9.00
Mini Mod, 1P3W, 600A MLO, (5) 125A Ringless sockets TMMR6512R, TMMR6512RF, TMMR6512RHB 2 36.28 41.59 7.00 12.56 9.00
Mini Mod, 1P3W, 600A MLO, (6) 125A Ring sockets TMM6612R, TMM6612RF 2 36.28 41.59 7.00 12.56 9.00
Mini Mod, 1P3W, 600A MLO, (6) 125A Ringless sockets TMMR6612R, TMMR6612RF, TMMR6612RHB 2 36.28 41.59 7.00 12.56 9.00
Mini Mod, 1P3W, 400A MLO, (2) 200A Ring sockets TMM4220R 5 25.50 42.69 7.00 18.44 12.13
Mini Mod, 1P3W, 400A MLO, (2) 200A Ringless sockets TMMR4220R, TMMR4220RF, TMMR4220RHB 5 25.50 42.69 7.00 18.44 12.13
Mini Mod, 1P3W, 600A MLO, (3) 200A Ring sockets TMM6320R, TMM6320RF 5 25.50 64.56 7.00 30.56 12.13
Mini Mod, 1P3W, 600A MLO, (3) 200A Ringless sockets TMMR6320R, TMMR6320RF, TMMR6320RHB 5 25.50 64.56 7.00 30.56 12.13
Mini Mod, 1P3W, 600A MLO, (4) 200A Ring sockets TMM6420R, TMM6420RF 5 25.50 64.56 7.00 18.44 12.13
Mini Mod, 1P3W, 600A MLO, (4) 200A Ringless sockets TMMR6420R, TMMR6420RF, TMMR6420RHB 5 25.50 64.56 7.00 18.44 12.13
Mini Mod, 1P3W, 600A MLO, (5) 200A Ring sockets TMM6520R 4 38.75 52.44 7.00 18.44 12.13
Mini Mod, 1P3W, 600A MLO, (5) 200A Ringless sockets TMMR6520R, TMMR6520RF, TMMR6520RHB 4 38.75 52.44 7.00 18.44 12.13
Mini Mod, 1P3W, 600A MLO, (6) 200A Ring sockets TMM6620R 4 38.75 52.44 7.00 18.44 12.13
Mini Mod, 1P3W, 600A MLO, (6) 200A Ringless sockets TMMR6620R, TMM6620RF, TMMR6620RHB 4 38.75 52.44 7.00 18.44 12.13
1Figures 2, 3 and 5 have removable drip hood and open end wall.
Knockouts
Symbol A B C D E F G H I J K L
1 1
2 2
3
4
1 1 1 1
Conduit 114 114 114 114
Size 112 112 112 112 112 112
in 2 2 2 2 2 2
Inches 212 212 212 212 212
3 3 3 3
312 312 312
4 4 4
5
Figure 1 Figure 2
Dimensions
Product Width Height Depth Section A Section B
Description Number Figure No.1 (in inches) (in inches) (in inches) (in inches) (in inches)
Meter Stack, 1P3W, (2) 125A Ring sockets, 800A horizontal bus TMP8212R, TMP8212RF3 1 12.26 41.60 6.62 21.61 9.00
TMPR8212R, TMPR8212RHB2, 1 12.26 41.60 6.62 21.61 9.00
Meter Stack, 1P3W, (2) 125A Ringless sockets, 800A horizontal bus
TMPR8212RF3, TMPR8212RHBF2,3
Meter Stack, 1P3W, (3) 125A Ring sockets, 800A horizontal bus TMP8312R, TMP8312RF3 1 12.26 41.60 6.62 21.61 9.00
TMPR8312R, TMPR8312RHB2 , 1 12.26 41.60 6.62 21.61 9.00
Meter Stack, 1P3W, (3) 125A Ringless sockets, 800A horizontal bus
TMPR8312RF3, TMPR8312RHBF2,3
Meter Stack, 1P3W, (4) 125A Ring sockets, 800A horizontal bus TMP8412R, TMP8412RF3 1 12.26 48.50 6.62 21.61 9.00
TMPR8412R, TMPR8412RHB2, 1 12.26 48.50 6.62 21.61 9.00
Meter Stack, 1P3W, (4) 125A Ringless sockets, 800A horizontal bus
TMPR8412RF3, TMPR8412RHBF2,3
Meter Stack, 1P3W, (5) 125A Ring sockets, 800A horizontal bus TMP8512R, TMP8512RF3 1 12.26 57.50 6.62 21.61 9.00
TMPR8512R, TMPR8512RHB2, 1 12.26 57.50 6.62 21.61 9.00
Meter Stack, 1P3W, (5) 125A Ringless sockets, 800A horizontal bus
TMPR8512RF3
Meter Stack, 1P3W, (6) 125A Ring sockets, 800A horizontal bus TMP8612R, TMP8612RF3 1 12.26 66.50 6.62 21.61 9.00
TMPR8612R, TMPR8612RHB2, 1 12.26 66.50 6.62 21.61 9.00
Meter Stack, 1P3W, (6) 125A Ringless sockets, 800A horizontal bus
TMPR8612RF3
Meter Stack, 1P3W, (2) 125A Ring sockets, 800A horizontal bus TMP8220R 2 13.38 52.36 6.62 30.55 12.13
TMPR8220R, TMPR8220RHB2, 2 13.38 52.36 6.62 30.55 12.13
Meter Stack, 1P3W, (2) 125A Ringless sockets, 800A horizontal bus
TMPR8220RF3
Meter Stack, 1P3W, (3) 125A Ring sockets, 800A horizontal bus TMP8320R, TMP8320RF3 2 13.38 52.36 6.62 18.42 12.13
TMPR8320R, TMPR8320RHB2, 2 13.38 52.36 6.62 18.42 12.13
Meter Stack, 1P3W, (3) 125A Ringless sockets, 800A horizontal bus
TMPR8320RF3
Meter Stack, 1P3W, (4) 125A Ring sockets, 800A horizontal bus TMP8420R, TMP8420RF3 2 13.38 64.51 6.62 18.42 12.13
TMPR8420R, TMPR8420RHB2, 2 13.38 64.51 6.62 18.42 12.13
Meter Stack, 1P3W, (4) 125A Ringless sockets, 800A horizontal bus
TMPR8420RF3, TMPR8420RHBF2,3
Meter Stack, 1P3W, (5) 125A Ring sockets, 800A horizontal bus TMP8520R, TM8520RBUS4 2 13.38 74.96 6.62 16.76 12.13
TMPR8520R, TMPR8520RHB2,
Meter Stack, 1P3W, (5) 125A Ringless sockets, 800A horizontal bus TMPR8520RF3, TMPR8520RBUS4 2 13.38 74.96 6.62 16.76 12.13
TMPR8520RHBBUS2,4
Meter Stack, 1P3W, (2) 125A Ring sockets, 1200A horizontal bus TMP12212R, TMP12212RF3 1 12.26 41.60 6.62 21.61 9.00
TMPR12212R, TMPR12212RHB2,
Meter Stack, 1P3W, (2) 125A Ringless sockets, 1200A horizontal bus TMPR12412RF + (2) TMCB12B3, 1 12.26 41.60 6.62 21.61 9.00
TMPR12212RHBF2,3
Meter Stack, 1P3W, (3) 125A Ring sockets, 1200A horizontal bus TMP12312R, TMP12312RF3 1 12.26 41.60 6.62 12.61 9.00
TMPR12312R, TMPR12312RHB2,
Meter Stack, 1P3W, (3) 125A Ringless sockets, 1200A horizontal bus TMPR12412RF + (1) TMCB12B3, 1 12.26 41.60 6.62 12.61 9.00
TMPR12312RHBF2,3
Meter Stack, 1P3W, (4) 125A Ring sockets, 1200A horizontal bus TMP12412R, TMP12412RF3 1 12.26 48.50 6.62 12.61 9.00
TMPR12412R, TMPR12412RHB2 1 12.26 48.50 6.62 12.61 9.00
Meter Stack, 1P3W, (4) 125A Ringless sockets, 1200A horizontal bus
TMPR12412RF3, TMPR12412RHBF2,3
Meter Stack, 1P3W, (5) 125A Ring sockets, 1200A horizontal bus TMP12512R, TMP12512RF3 1 12.26 57.50 6.62 12.61 9.00
TMPR12512R, TMPR12512RHB2, 1 12.26 57.50 6.62 12.61 9.00
Meter Stack, 1P3W, (5) 125A Ringless sockets, 1200A horizontal bus
TMPR12512RF3
Meter Stack, 1P3W, (6) 125A Ring sockets, 1200A horizontal bus TMP12612R, TMP12612RF3 1 12.26 66.50 6.62 12.61 9.00
TMPR12612R, TMPR12612RHB2, 1 12.26 66.50 6.62 30.55 9.00
Meter Stack, 1P3W, (4) 125A Ringless sockets, 1200A horizontal bus
TMPR12612RF3
Meter Stack, 1P3W, (2) 200A Ring sockets, 1200A horizontal bus TMP12220R 2 13.38 52.36 6.62 30.55 12.13
TMPR12220R, TMPR12220RHB2, 2 13.38 52.36 6.62 18.42 12.13
Meter Stack, 1P3W, (2) 200A Ringless sockets, 1200A horizontal bus
TMPR12420RF + (2) TMCB20B3
Meter Stack, 1P3W, (3) 200A Ring sockets, 1200A horizontal bus TMP12320R, TMP12320RF3 2 13.38 52.36 6.62 18.42 12.13
TMPR12320R, TMPR12320RHB2, 2 13.38 52.36 6.62 18.42 12.13
Meter Stack, 1P3W, (3) 200A Ringless sockets, 1200A horizontal bus
TMPR12420RF + (1) TMCB20B3
Meter Stack, 1P3W, (4) 200A Ring sockets, 1200A horizontal bus TMP12420R, TMP12420RF3 2 13.38 64.51 6.62 18.42 12.13
TMPR12420R, TMPR12420RHB2, 2 13.38 64.51 6.62 18.42 12.13
Meter Stack, 1P3W, (4) 200A Ringless sockets, 1200A horizontal bus
TMPR12420RF3, TMPR12420RHBF 2,3
Meter Stack, 1P3W, (5) 200A Ring sockets, 1200A horizontal bus TMP12520R, TM12520RBUS4 2 13.38 74.96 6.62 16.76 12.13
TMPR12520R, TMPR12520RHB2,
Meter Stack, 1P3W, (5) 200A Ringless sockets,1200A horizontal bus TMPR12520RF3, TMPR12520RBUS4, 2 13.38 74.96 6.62 16.76 12.13
TMPR12520RHBBUS2,4
Single-Phase, Three-Wire 225 A TMPR12122R 3 18 25.375 8.75 13
Single-Phase, Three-Wire 225 A TMPR12222R 3 18 52.625 8.75 27 14
Single-Phase, Three-Wire 225 A TMPR12322R 3 18 52.625 8.75 13 14
Single-Phase, Three-Wire 225 A TMPR12422R 3 18 66.625 8.75 13 14
Single-Phase, Three-Wire 225 A TMP8120RTAB 12 21.375 25 8.75
Single-Phase, Three-Wire 225 A TMP8120RTAC 12 21.375 25 8.75
1Figures referenced are on pages 2-29 and 2-30. Figures 1 through 8 have a removable top drip hood. Figure 4 has a removable top drip hood and open end wall.
2Includes horn by-pass.
3F units have an additional cotter pin that has been added to the meter socket assembly that will keep the meter socket from detaching from the base.
This change meets the new MEG requirements and should not be used outside of the state of Florida.
4Parts with BUS on the end have the horizontal bussing centerline on the 3rd meter rather than 2nd meter, making the unit shorter from the centerline for
applications where height of top meter may be an issue.
Dimensions
Product Width Height Depth Section A Section B
Description Number Figure No.1 (in inches) (in inches) (in inches) (in inches) (in inches)
Single-Phase, Three-Wire 225 A TMP8120RTBC 12 21.375 25 8.75
Single-Phase, Three-Wire 400 A TMPR12140RB 3 18 52.625 8.75 27
Three-Phase, Four-Wire 225 A TMPR312122R 3 18 25.375 8.75 13
Three-Phase, Four-Wire 400 A TMPR312140TR 3 18 52.625 8.75 41
Three-Phase, Four-Wire 225 A TMPR312222R 3 18 52.625 8.75 27 14
Three-Phase, Four-Wire 225 A TMPR312322R 3 18 52.625 8.75 13 14
Three-Phase, Four-Wire 225 A TMPR312422R 3 19 66.625 8.75 13 14
Three-Phase, Four-Wire 200 A TMP312220RT 3 21.38 43.00 8.75 27 14
Three-Phase, Four-Wire 200 A TMP312320RT 3 21.38 62.44 8.75 13 14
Three-Phase, Four-Wire 400 A TMPR312140RB 3 18 52.625 8.75 27
Main Breaker Modules TMPSB4R 4 20 47.625 11.75
Main Breaker Modules TMP3SB4R 4 20 47.625 11.75
Main Breaker Modules TMPSB6R 4 20 47.625 11.75
Main Breaker Modules TMP3SB6R 4 20 47.625 11.75
Main Breaker Modules TMPSB8R 4 20 47.625 11.75
Main Breaker Modules TMP3SB8R 4 20 47.625 11.75
Main Breaker Modules TMPSB10R 4 20 47.625 11.75
Main Breaker Modules TMP3SB10R 4 20 47.625 11.75
Main Breaker Modules TMPSB12R 4 20 47.625 11.75
Main Breaker Modules TMP3SB12R 4 20 47.625 11.75
Main Breaker Modules TMPSHB4R 4 20 47.625 11.75
Main Breaker Modules TMP3SHB4R 4 20 47.625 11.75
Main Breaker Modules TMPSHB6R 4 20 47.625 11.75
Main Breaker Modules TMP3SHB6R 4 20 47.625 11.75
Main Switch Modules TMPFT4R 4 20 47.625 11.75
Main Switch Modules TMP3FT4R 4 20 47.625 11.75
Main Switch Modules TMPFT6R 4 20 47.625 11.75
Main Switch Modules TMP3FT6R 4 20 47.625 11.75
Main Switch Modules TMPFT8R 4 20 47.625 11.75
Main Switch Modules TMP3FT8R 4 20 47.625 11.75
Main Switch Modules TMPFB4R 4 20 66.5 6.625
Main Switch Modules TMP3FB4R 4 20 66.5 6.625
Main Switch Modules TMPFB6R 4 20 66.5 6.625
Main Switch Modules TMP3FB6R 4 20 66.5 6.625
Main Switch Modules TMPFB8R 4 20 66.5 6.625
Main Switch Modules TMP3FB8R 4 20 66.5 6.625
Main Switch Modules TMPFB12R 10 36.5 66.5 19.5
Main Switch Modules TMPFT12R 10 36.5 66.5 19.5
Main Switch Modules TMP3FB12R 10 36.5 66.5 19.5
Main Switch Modules TMP3FT12R 10 36.5 66.5 19.5
Main Switch Modules TMP3FB16R 10 36.5 66.5 19.5
Main Switch Modules TMP3FT16R 10 36.5 66.5 19.5
Main Switch Modules TMP3FB20R 10 36.5 66.5 19.5
Main Switch Modules TMP3FT20R 10 36.5 66.5 19.5
Main Switch Modules TMPFB4RCLL 4 20 61 11.75
Main Switch Modules TMPFB6RCLL 4 20 61 11.75
Main Switch Modules TMPFB8RCLL 4 20 61 11.75
Main Switch Modules TMPFB12RCLLT 4 33.5 61 11.75
Main Switch Modules TMP3FB4RCLL 4 20 61 11.75
Main Switch Modules TMP3FB6RCLL 4 25.38 61 11.75
Main Switch Modules TMP3FB8RCLL 4 25.38 61 11.75
Main Switch Modules TMP3FB12RCLLT 33.5 61 11.875
Main Switch Modules TMPFB12RT 4 33.5 52.625 11.875
Main Switch Modules TMP3FB12RT 4 33.5 52.75 11.875
Main Lug Modules TMP3L4R 5 13.5 48.75 7
Main Lug Modules TMP3L6R 5 13.5 48.75 7
Main Lug Modules TMPL8R 4 20 47.625 11.75
Main Lug Modules TMP3L8R 4 20 47.625 11.75
Main Lug Modules TMPL12R 4 20 47.625 11.75
Main Lug Modules TMP3L12R 4 20 47.625 11.75
Main Lug Modules TMPL16R 32.875 60.125 11.4375
Main Lug Modules TMP3L16R 32.875 60.125 11.4375
Main Lug with Feed Through TMP3L12RCRIS 28.48 60.56 11.65
Main Lug with Feed Through TMP3L16RCRIS 28.48 60.56 11.65
Main Pull Box Modules TMPU4R 6 16.325 44.825 7.825
Main Pull Box Modules TMP3U4R 6 16.325 44.825 7.825
Main Pull Box Modules TMPU8R 7 24.325 46.825 11.825
Main Pull Box Modules TMP3U8R 7 24.325 46.825 11.825
Main Pull Box Modules TMPU12R 8 32.5 56.825 12
Main Pull Box Modules TMP3U12R 8 32.5 56.825 12
Elbow TMPE12 11 16 17.5 4.938
Elbow TMPE12A 11 12 17.5 4.938
1Figures referenced are on pages 2-29 and 2-30. Figures 1 through 8 have a removable top drip hood. Figure 4 has a removable top drip hood and open end wall..
Knockouts
Symbol A B C D E F G H I J K L M
1 1
2 2
3
4
1 1 1 1
Conduit 114 114 114 114
Size 112 112 112 112 112 112
in 2 2 2 2 2 2 2
Inches 212 212 212 212 212 212
3 3 3 3 3
312 312 312 312
4 4 4 4
5
Introduction .....................................................................................................3-2
Selection Guide ..............................................................................................3-3
Commercial WattStation
Overview, Features and Benefits ........................................................3-4
WattStation Pedestal EV Charger
Specifications and Ordering Information ....................................3-5
WattStation Wall Mount EV Charger
Specifications and Ordering Information ....................................3-6
Commercial DuraStation
Overview, Features and Benefits ........................................................3-7
Specifications and Ordering Information........................................3-8
Connect Software
Overview, Features and Benefits ........................................................3-9
Specifications and Ordering Information.....................................3-10
Residential Charging Stations Wall Mount Units
Overview, Features and Benefits......................................................3-11
Specifications and Ordering Information.....................................3-12
Utility Supply
Submetering
Introduction
Look to GEs broad-based expertise to make an integrated, connected, and stylish EV
charging solution a practical reality for your location. Our market knowledge and product
development has set the standard for user-friendly designs and reliability. GE EV charg-
ing stations offer
WattStation WattStation
Pedestal Wall Mount DuraStation
Software Cloud Software Standard Optional Optional
Connectivity CAT5/WiFi/Cell Standard Optional Optional
Point of Sale (PayPal/CC) Standard Optional Optional
Access Control (RFID) Standard Optional Optional WattStation Pedestal
Custom Wraps Optional Optional Optional
DuraStation
Overview
The GE Commercial WattStation line gives you a superior combi-
nation of design, style, and features for electric vehicle charging
systems. Available in a sleek pedestal or stylish wall mount, both
units feature GEs WattStation Connect software which lets you
manage your WattStation network remotely, enable EV drivers to
find stations at your facilities, provide payment options and gener-
ate valuable usage and user reports. Non-network wall mount
units for residential use are also offered.
Wall Mount
Easy to use display panel and a wraparound cord management
system to keep the charger cord off the ground between uses.
Both hardwired and wall plug options are available.
Pedestal Specifications
SAE Compliant Level II per J1772
Vehicle Interface SAE J1772 EV connector
Cable Length 15.5 feet (as allowed by the NEC)
AC Charging Power Output 7.2kW (240VAC @ 30A)
Voltage and Current Rating 208-240VAC @ 30A
AC Power Input 208-240VAC requiring only Line 1, Line 2, and Earth ground
Short Circuit Rating 5kA @ 240VAC
Recommended Service Panel Breaker 2-pole 40A breaker on dedicated circuit
Ground Fault Protection Internal 20mA CCID w/ auto re-closure, does not require a GFCI in service panel
Communication Option CAT5 Ethernet, WiFi or Cellular (CDMA)
Metering Accuracy 2% accurate on voltage and current
RFID Reader HID Multi-Class RP15
Display Screen LED Icon
Standby Power 5W typ.
Outdoor Rated NEMA 3R
Safety Compliance (ETL Listing) UL 2231, UL 2251, UL 2594, cUL 2231, cUL 2594, NEC 625, SAE J1772
Surge Protection 6kV @ 3,000A
EMI Compliance FCC Part 15 Class A
Operating Temperature -30C to +50C ambient (Operating temp. limit for cord reel is -15C)
Operating Humidity Up to 95% non-condensing
Approximate Shipping Weights 120 lbs.
Dimensions 51.1"H x 14.9"D
Ordering Information
Type Connect Communication Product No.
Single Pedestal w/ Connect Yes CAT 5 EVWPR3GEXXGB
Single Pedestal w/ Connect Yes WiFi EVWPR3GWXXGB
Single Pedestal w/ Connect1 Yes Cellular (CDMA)1 EVWPR3GZXXGB
1Required Cellular Access (Annual) per J1772 Connector Yes Cellular (CDMA) EVSWWC124
Accessories
Type Product No.
EV Connect (annual per connector) EVSWWC126
RFID Access Cards - pack of 10 GE branded cards EVRCG10
Customized Vinyl Wrap - Factory installed EVWRAPSETUP
Standards Compliance
SAE J1772
NEC 625
UL 2231, 2251, 2594
NEMA and NIST
cUL 2594 and 2231
Ordering Information
Type Connect Communication Product No.
Wall Mount w/Connect Yes WiFi EVWWR3BWXCGB
Wall Mount w/Connect1 Yes Cellular (CDMA)1 EVWWR3BZXCGB
1Required Cellular Access (Annual) per J1772 Connector Yes Cellular (CDMA) EVSWWC124
Accessories
Type Product No.
EV Connect (annual per connector) EVSWWC126
RFID Access Cards - pack of 10 GE branded cards EVRCG10
Customized Vinyl Wrap - Factory installed EVWRAPSETUP
Overview
GE DuraStation is our most versatile line of electric vehicle
chargers. It offers a broad array of mounting options, user access
control and payment methods with the optional WattStation
Connect Software which includes an RFID reader. Rugged, durable
and time-tested, DuraStation has been successfully used in the
extreme heat of summer (rated to 50 degrees Celsius) to the dead
of winter (rated to -30 degrees Celsius).
NEC 625
UL 2231, 2251, 2594 Ordering Information
cUL 2231, 2594 Type Connect Communication Product No.
Accessories
Type Product No.
EV Connect (annual per connector) EVSWWC126
RFID Access Cards - pack of 10 GE branded cards EVRCG10
Customized Vinyl Wrap - Factory installed EVWRAPSETUP
Our Commerical WattStation and DuraStation EV chargers feature the ability to connect
to the cloud for remote monitoring and management of your charging stations.
Overview
Advanced Network Capabilities: WattStation Connect software is a web-enabled, cloud-
based system to configure and manage your optionally equipped GE WattStation or GE
DuraStation, offering user and usage management, controlled access and third party
payment processing. Our Application Programming Interface (API) helps you to inter-
face with your own building or fleet management systems including email. You just
choose the communications platform (CAT5, WiFi or available Cellular1).
EV Connect
Through our partnership with EV Connect, GE is proud to provide additional network
management capabilities that enhance a site operators ability to control many aspects
of the charge station.
Specifications
Registration Drivers: Register by entering your name, email address and create a password
(terms and conditions apply)
Business Owners: Users may also request access to a business owner domain.
Find Station Locate stations based on address, zip code or dragging the map to your specific area of interest.
Users will be able to view stations, availability and station details (pricing, address, owner name, etc)
Dashboard Take your EV infrastructure project to the next level with the WattStation EV charger and WattStation
Connect software. This integrated hardware and software solution can help manage your charging
stations remotely, enable EV drivers to find stations at your facilities, generate valuable reports, and
engage with customers in new and meaningful ways.
Users Authorize users, define user groups, manage user accounts
Stations Provision and set-up of new installations, manage stations and update information, and set-up
automatic message notifications.
Planning/Pricing Options Define and create pricing models for stations and user groups. Options include:
Pay Flat Rate. E.g., set a fixed price, regardless of the duration of the charging session.
Pay As You Charge. E.g., set a fixed price for every hour your driver will charge his vehicle.
Pay By Time. E.g., set a fixed price based on the duration (hourly) of each transaction.
Other customized options available.
Access Cards Management Manage access cards and user assignments for your charging stations. GE offers a 10-pack Access
Card that Owners can purchase and distribute for free authorized access.
Reports Generate various reports for station operators, including revenue, energy usage, system faults, and
per driver charge session.
Settings Update your account information (name, address, contact info, password, etc.) and allow EV Driver to
enroll with PayPal or PlugShare for other pricing options, set up permissions and accept payment for
EV charging by mobile phone.
Mobile Application (EV Driver) This mobile app provides three functionalities:
Find a Station
Pay for Usage
Account management
Mobile Application Availability GE WattStation
PlugShare
Apple App Store
Android Market
Ordering Information
Description Product No.
WattStation Connect Cellular Data Access Fee EVSWWC124
EV Connect (annual per connector) EVSWWC126
RFID Access Cards pack of 10 GE branded cards EVRCG10
WattStation DuraStation
Level 2 Charging Standard Standard
7.2kWh Rating Standard Standard
Outdoor Rating Standard Standard
NEMA 6-50P Installation Optional N/A
Cord Length 20 feet 18 feet
3 year warranty Standard Standard
Custom Wraps Optional N/A
Overview
The WattStation Wall Mount design is suitable for various commercial and residential
locations. This product offers Level II charging, which is capable of reducing charge time
from 12-18 hours to 4-8 hours, with service needs of 208-240Vac at 40A, assuming a WattStation Wall Mount
24kWh battery and a full-cycle charge.
Standards Compliance
SAE J1772
NEC 625
cETL and ETL listed
UL 2594
cUL 2594
NEMA and NIST
ADA Compliance
Reference Publications
WattStation Wall Mount Brochure DEA-528
WattStation Wall Mount Application Guide DET-746
WattStation Wall Mount Fact Sheet DEQ-167
WattStation Wall Mount User Manual DEA-533
Ordering Information
Type Product No.
WattStation Wall Mount Plug In EVWSWBC-CP01
WattStation Wall Mount Hardwired EVWSWBH-CP03
DuraStation Wall Mount Hardwired EVDSWGH-CP01
TG4322
TH3361SS
TDT3362
Enclosure Types
Type 1Enclosures constructed for indoor use to provide a degree of protection to
personnel against incidental contact with the enclosed equipment and to provide a
degree of protection against falling dirt.
Type 3REnclosures constructed for either indoor or outdoor use to provide a degree
of protection to personnel against incidental contact with the enclosed equipment; to
provide a degree of protection against falling dirt, rain, sleet, and snow; and that will
be undamaged by the external formation of ice on the enclosure
Type 4Enclosures constructed for either indoor or outdoor use to provide a degree
of protection to personnel against incidental contact with the enclosed equipment;
to provide a degree of protection against falling dirt, rain, sleet, snow, windblown dust,
splashing water, and hose-directed water; and that will be undamaged by the external
formation of ice on the enclosure.
Type 4XEnclosures constructed for either indoor or outdoor use to provide a degree
of protection to personnel against incidental contact with the enclosed equipment; to
provide a degree of protection against falling dirt, rain, sleet, snow, windblown dust,
splashing water, hose-directed water, and corrosion; and that will be undamaged by
the external formation of ice on the enclosure.
Type 5Enclosures constructed for indoor use to provide a degree of protection to
personnel against incidental contact with the enclosed equipment; to provide a degree
of protection against falling dirt; against settling airborne dust, lint, fibers, and flyings;
and to provide a degree of protection against dripping and light splashing of liquids.
Type 12Enclosures constructed (without knockouts) for indoor use to provide a degree
of protection to personnel against incidental contact with the enclosed equipment; to
provide a degree of protection against falling dirt; against circulating dust, lint, fibers,
and flyings; and to provide a degree of protection against dripping and light splashing
of liquids.
Application Note: For applications of disconnecting means in motor circuit applications,
disconnect must be sized based on ampacity per NEC 430-110, but not less than 115%
of Motor Name-Plate current.
T H N 3 3 6 1 R DC
GE Identification
Note: This information is provided for interpreting numbers. It should not be used to build product numbers.
Type TG Switches
Designed for residential or light commercial applications
where duty is not severe
30-600 amps Safety
Fusible, Two-pole, 120/240 and 240 Volts AC; 250 Volts DC;
240Vac / 250Vdc maximum in fusible or non-fusible units SwitchesThree-wire switching neutral, 240 Volts AC
NEMA Type 1 (indoor) or NEMA Type 3R (outdoor) enclosures
Direct-drive, quick-make, quick-break mechanism snaps
contacts open and closed providing positive ON/OFF indication
Self-leveling, three-point mounting system
Integral cover interlock
Visible confirmation of plated blade contact positions
Spring reinforced fuse clips assure reliable contact for
cool operation. Suitable for Class H, K, J or R fuses,
where applicable.
UL Listed short-circuit rating is 10,000 rms symmetrical N
amps standard
With Class R fuses and fuse kits installed, 30-200 amp switches
have UL Listed short circuit rating of 100,000 rms symmetrical
amps
UL Listed as service entrance equipment when installed in
accordance with the National Electric Code Fusible, Four-wire switching neutral, 208/120 and 240 Volts AC
No Fuse, Two-pole, 240 Volts AC; 250 Volts DC (100-600 amps only);
Three-pole, 240 Volts AC or Two-pole with Switching Neutral
For Type 3R Enclosure: 30-200 amp devices have removable closing cap. Order hubs for these devices separately on page 4-25.
Larger amp devices require field cut openings and customer-supplied hub.
General Duty safety switches are not suitable for use as service equipment in Canada. Use Heavy Duty safety switches.
1 Add "B" suffix for factory reversed bottom feed. (e.g., TG3224B.) UL Listed.
2 Single make single break mechanism
3 Not suitable for use as service equipment. Solid neutral not available.
4 NEMA Type 3R Fusible or Non-Fusible versions, 400-600 ampere rating, available in heavy duty, type TH models. See pages 4-8 to 4-10.
Type TH Switches
Designed for commercial and industrial applications where
safety, high performance and continuity of service are essential Fusible, Two-pole, Fusible,
30-1200 amps 240 Volts AC; 250 Volts DC Four-wire switching neutral,
600Vac maximum, 600Vdc maximum in fusible or non-fusible and Fusible Two-pole, 208/120 and 240 Volts AC
units 600 Volts DC,
NEMA Type 1 (indoor), Type 3R (outdoor), Type 4/4X (water and (2 poles in series for 600 Vdc)
dust-tight, corrosion resistant) or Type 5/12 (drip and dust-tight)
enclosures
Donut handle ideal for hook stick operation and accepts
3 padlocks in the OFF position
Direct-drive, quick-make, quick-break mechanism snaps con-
tacts open and closed providing positive ON/OFF indication N
Self-leveling, three-point mounting system
Coin-proof, defeatable interlock
Visible confirmation of plated blade contact positions
Spring reinforced fuse clips assure reliable contact for cool
operation. Suitable for Class H, K, J or R fuses, where applicable. Fusible, Three-pole, Non-fusible,
With Class R fuses or J fuses, 30-600 amp switches have UL Three-wire switching neutral, Two-pole, 600 Volts DC
Listed short circuit rating of 200,000 rms symmetrical amps 120/240 and 240 Volts AC
Switches rated 800-1200 amps use Class L fuses and have a
UL Listed short circuit rating of 100,00 rms symmetrical amps
UL Listed as service entrance equipment when installed in
accordance with the National Electric Code
1 Type 1 Enclosure: 200-600 Amp devices available factory reversed for bottom feed. Add "B" suffix.
2 For switches CSA Certified for service entrance, add C suffix.
3 For switches suitable for service entrance applications in Canada, order TH3267C, TH3267RC, TH3268C and TH3268RC.
4 Available with Viewing Window. Add "W" suffix.
5 For switches suitable for service entrance applications in Canada, order TH4325RC and TH4326RC.
6 Rated 600 Vac only. Accepts Class L fuses only. Type HD electrical performance does not apply.
7 3 wire with neutral kit ordered separately. For 800A use TNI67; for 1200A use TNI68A.
8 4 wire with neutral kit ordered separately. For 400A use TNI65 or TNI65A.
9 4 wire with neutral kit ordered separately. For 600A use TNI66.
Note: Many Heavy Duty Switches are available with a Stainless Steel enclosure. See page 4-12.
1 3 wire with neutral kit ordered separately. For 800A use TNI67; for 1200A use TNI68A.
2 Rated 600 Vac only. Accepts Class L fuses only. Type HD electrical performance does not apply.
3 Type 1 Enclosure: 200-600 Amp devices available, factory reversed for bottom feed. Add B suffix.
4 4 wire with neutral kit ordered separately. For 800A use TNI67; for 1200A use TNI68A.
5 Farm Switch with oversize Type 3R enclosure with vertical hinge. See page 4-28 for dimensions.
6 Available with Viewing Window. Add W suffix.
7 For switches suitable for service entrance applications in Canada, order TH3267C, TH3267RC, TH3268C and TH3268RC.
NEMA Type 4X Enclosure Grade 304 Stainless Steel (see footnote below for 316 Stainless Steel offering)
Horsepower Ratings DC Horsepower Ratings
Single-Phase 240 Vac Three-Phase 240 Vac 250 Vdc
Amperage Product Number Standard Fuse Time Delay Standard Fuse Time Delay Standard Fuse
Fusible / 2 Pole / 2 Wire / 240V / 50/60 Hz
30 TH2221SS1,2 1.5 3 5
60 TH2222SS1,2 3 10 10
Fusible / 2 Pole / 3 Wire / 240V / 50/60 Hz (Neutral factory installed)
30 TH3221SS1,2 1.5 3 5
60 TH3222SS1,2 3 10 10
100 TH3223SS 1,2 7.5 15 20
N
200 TH3224SS 1,2 15 40
400 TH3225SS 50 125 50
600 TH3226SS 75 200 50
Fusible / 3 Pole / 3 Wire / 240V / 50/60 Hz
30 TH3321SS1,2 1.5 3 3 7.5 5
60 TH3322SS1,2 3 10 7.5 15 10
Fusible / 3 Pole / 4 Wire / 240V / 50/60 Hz (Neutral factory installed)
30 TH4321SS1,2 1.5 3 3 7.5 5
60 TH4322SS1,2 3 10 7.5 15 10
100 TH4323SS1,2 7.5 15 15 30 20
N
200 TH4324SS1,2 15 25 60 40
400 TH4325SS 50 125 50
600 TH4326SS 75 200 50
Selected Double Throw safety switches available in stainless steel. Refer to page 4-16.
Note: See page 4-2 for Short Circuit Ratings and page 4-20 for Lug Wire Sizes Line and Load Terminals.
Type TH Interrupting and Withstand Ratings Lug Wire Sizes Line and Load Terminals
Interrupting Rating Amps3 Fuse Clearing4 Wire Range Wire Range
Ampere Rating Symmetrical 600 volts AC, 3-phase (I2t x 103) Ampere Rating AWG/kcmil Copper AWG/kcmil Aluminum
30A 360 50 30A (240V) 14-8 12-8
60A 1200 200 30A (600V) 14-6 14-6
100A 1200 500 60A 14-2 14-2
200A 3,400 2,000 100A 14-1/0 12-1/0
400A 10,000 6,000 200A 2-250
600A 10,000 12,000 400A (1) 2-600 or (2) 1/0-250
3Maximum current at rated voltage that switch will interrupt three times without 600A (2) 4-600
ON ON
Non-fusible, Three-pole, Three-wire, 600 Volts AC, 250 Volts DC
OFF OFF
ON ON
N
Fusible / 3 Pole / 3 Wire / Fusible / 3 Pole / 3 Wire / Non-fusible, Three-wire switching neutral, 120/240 Volts AC
Two Sources / One Load Two Loads / One Source
Non-Fusible
Product Number Horsepower Rating DC Horsepower Rating Lug Wire Sizes Line and Load Terminals
NEMA
NEMA NEMA Type 4X Three-Phase
Amperage Type 1 Type 3R Stainless
Rating Indoor Outdoor Steel 240 Vac 480 Vac 600 Vac 125 Vdc 250 Vdc AWG/kcmil
Non-Fusible / 3 Pole / 3 Wire / 240V / 50/60 Hz
30 TC35321 TC35321R 2 14-8 (Cu)
60 TC35322 TC35322R 3 14-4 (Cu)
100 TC35323 TC35323R 7.5 14-1/0 (Cu)
200 TC35324 TC35324R 15 6-250 (Cu)
400 TC35325 TC35325R 30 (2) 1/0-250 (Cu) or 2-600 (Cu)
TC35326 2 50 (2) 3/0-350 (Cu) or 2-600 (Cu)
600
TC35326R 125 250 350 50 (2) 250 - (2) 500 (Cu/Al)
800 TC353274 TC35327R4 125 (3) 250 - (3) 500 (Cu/Al)
1200 TC35328 TC35328R (4) 1/0 - (4) 750 (Cu/Al)
Non-Fusible / 3 Pole / 3 Wire / 600V / 50/60 Hz
30 TC35361 TC35361R TC35361SS 10 20 30 3 5 14-2 (Cu/Al)
TC35362 TC35362R 10 10 10 14-4 (Cu)
60
TC35362SS 20 50 60 5 10 14-2 (Cu/Al)
TC35363 TC35363R 15 15 15 14-1/0 (Cu)
100
TC35363SS 40 75 100 20 14-1/0 (Cu/Al)
TC35364 TC35364R 30 30 30 6-250 (Cu)
200
TC35364SS 60 125 150 40 6-250 (Cu/Al)
TC353651,2,3 (2) 1/0-250 (Cu) or 2-600 (Cu)
400
TC35365R TC35365SS 125 250 350 50 (2) 1/0 - (2) 300 (Cu/Al) or 5 (1) 1/0 - 750 (Cu/Al)
TC353661,2 (2) 3/0-350 (Cu) or 2-600 (Cu)
600
TC35366R TC35366SS 125 250 350 (2) 250 - (2) 500 (Cu/Al)
800 TC353674 TC35367R4 TC35367SS 125 250 350 (3) 250 - (3) 500 (Cu/Al)
1200 TC35368 TC35368R (4) 1/0 - (4) 750 (Cu/Al)
1 Not UL Listed.
2 Not suitable for use as service equipment per NEC Article 702
3 No provision for auxiliary contact kit
4 Available with factory installed neutral. Add N suffix. For example: TC35327N.
5 Single barrel lug that accepts one or two cables per phase.
Type TC Accessories
Product Number Aux Contact
NEMA NEMA Type 4X
NEMA Type 3R Grade 304 1 Normally Open 2 Normally Open
Amperage Rating Type 1 Indoor Outdoor Stainless Steel Neutral Kit Ground Kit 1 Normally Closed 2 Normally Closed Control Pole
Non-Fusible / 3 Pole / 3 Wire / 240V
30 TC35321 TC35321R
TNK100 TGL1
60 TC35322 TC35322R
100 TC35323 TC35323R TNK100 TNG3 THAUXDT
200 TC35324 TC35324R TNK200 TNG3
400 TC35325 TC35325R TNK400 TGL6
TC35326 TGL6
600
TC35326R DT600NK DS16CP
800 TC35327 TC35327R1 DT800NK DS468GK DS200EK1 DS200EK2 DS16CP
1200 TC35328 TC35328R DT1200NK
Non-Fusible / 3 Pole / 3 Wire / 600V
30 TC35361 TC35361R TC35361SS DT100NK DS100GK DS200EK1 DS200EK2 DS16CP
TC35362 TC35362R TNK100 TGL1 THAUXDT
60
TC35362SS DT100NK DS100GK DS200EK1 DS200EK2 DS16CP
TC35363 TC35363R TNK100 TNG3 THAUXDT
100
TC35363SS DT100NK DS100GK DS200EK1 DS200EK2 DS16CP
TC35364 TC35364R TNK200 TNG3 THAUXDT
200
TC35364SS DT200NK DS200GK DS200EK1 DS200EK2 DS16CP
TC35365 TNK400 TGL6 THAUXDT
400
TC35365R TC35365SS DT400NK DS468GK DS200EK1 DS200EK2 DS16CP
TC35366 TGL6
600
TC35366R TC35366SS DT600NK DS16CP
800 TC35367 TC35367R1 TC35367SS DT800NK DS468GK DS200EK1 DS200EK2 DS16CP
1200 TC35368 TC35368R DT1200NK
1 Order same accessories for the "N" version.
BONDED
NEUT.
Service Equipment
No fuse UL1429
Enclosed Pull-out Switch
LISTED Fusible
GROUND
Wire Standard
EQUIP
Type Volts Fusing Amps HP Rating Product No. Range Package
Fusible 30 3 TF30R
Pullout 240V 60 10 TF60R
TFN60R 14-3 6
Non-Fusible 60 10
TFN60RGFR1
TNA60R1 No Fuse
Non-Automatic 240V Non-Fusible 60 10
TNA60RGFR1
1These disconnects include a GFCI outlet
Switching Neutral: Order standard switch of required number of poles and use dummy fuse in neutral pole.
1 Not suitable for type TG switches.
2 Not suitable for type TC Double Throw or TC Single Throw Non-Fusible
Note: All accessories are available in standard package of 1 unless otherwise noted.
THAUX66D
Equipment Ground TerminalsTwo lugs supplied per switch, provision for one additional lug.
Factory Installed Field Installed Crimp Lugs (See table on page 4-23)
Switch Ampere Rating Copper Aluminum Copper Aluminum
30A 14-6 14-6 14-8
60A 14-6 14-6 14-8
100A 14-4 14-4 8 6
200A 14-4 14-4 6 4
400A 14-1/0 14-1/0 3-2 1
600A 14-2/0 14-2/0 1 2/0
Class R Fusing Kit Field Installable, General Duty, Type TG, UL Listed
When specifications permit only Class R fuses to be used, these kits may be installed in
the safety switch to deter fuses other than Class R from being installed.
3060A = Fuse Clips
100200A = Rejection Pins
One kit required per two pole or three pole switch
Class J Fuse Field Conversion Kit, Heavy Duty, Type TH, UL Listed
TH switches, 30-400 amperes, 600 volt and 100-400 amperes, 240 volt, may be adapted
to accept Class J fuses without a kit by moving the load-block toward the switch base
and remounting.
Class R Fusing Kit Field Installable, Heavy Duty, Type TH, UL Listed
When specifications permit only Class R fuses to be used, these kits may be installed in
the safety switch to deter fuses other than Class R from being installed.
3060A = Fuse Clips
100200A = Rejection Pins
One kit required per two pole or three pole switch
Series Prefix Ampere Rating System Voltage Enclosure Type Product Number
30A 240Vac NEMA Type 1, 3R, 4/4X, 12 TRK12B
30A 600Vac NEMA Type 1, 3R TRK16B
30A 600Vac NEMA Type 4/4X, 12 TRK16SA TRK46A Class R Rejection Kit
60A 240Vac NEMA Type 1, 3R, 4/4X, 12 TRK22A
60A 600Vac NEMA Type 1, 3R, 4/4X, 12 TRK26A
TH
100A 240Vac 600Vac NEMA Type 1, 3R TRK46A
100A 240Vac 600Vac NEMA Type 4/4X, 12 TPBRK36A
200A 240Vac 600Vac NEMA Type 1, 3R, 4/4X, 12 TRK46A
400A 240Vac 600Vac NEMA Type 1, 3R, 4/4X, 12 TRK56A
600A 240Vac 600Vac NEMA Type 1, 3R, 4/4X, 12 TRK66A
TCCP
THGRIP
Heavy Duty, NEMA Type 4/4X (316 Stainless) Approximate Dimensions in inches D2
Product Dimension Dimension Dimension W2 Dimension Dimension D2 Weight KO Figure D
W2
Number H W (Box) (W/ Handle) D (Box) (W/ Handle) (lbs) Drawing # Number
TH3361SS316 13.3 9.4 10.1 4.9 9.4 18 10103091SH109
TH3361SS316-BA 13.3 9.4 10.1 4.9 9.4 18 10103091SH109
TH3362SS316 19.3 9.4 10.1 5.2 9.6 23 10103091SH109
TH3362SS316-BA 19.3 9.4 10.1 5.2 9.6 23 10103091SH109
H
TH3363SS316 25.4 13.4 14.3 5.2 9.6 36 10103091SH113
TH3363SS316-BA 25.4 13.4 14.3 5.2 9.6 36 10103091SH113
TH3364SS316 35.1 14.5 15.5 5.2 9.6 49 10103091SH113
TH3364SS316-BA 35.1 14.5 15.5 5.2 9.6 49 10103091SH113
THN3361SS316 11.3 9.4 10.1 4.9 9.4 16 10103091SH109 No KO
THN3361SS316-BA 11.3 9.4 10.1 4.9 9.4 9 10103091SH109
W
THN3362SS316 13.3 9.4 10.1 5.2 9.6 22 10103091SH109
THN3362SS316-BA 13.3 9.4 10.1 5.2 9.6 22 10103091SH109
Heavy Duty NEMA Type 4/4X
THN3363SS316 25.4 13.4 14.3 5.2 9.6 36 10103091SH113
THN3363SS316-BA 25.4 13.4 14.3 5.2 9.6 36 10103091SH113
THN3364SS316 35.1 14.5 15.5 5.2 9.6 50 10103091SH113
THN3364SS316-BA 35.1 14.5 15.5 5.2 9.6 50 10103091SH113
THN3365SS316 59.5 24.6 25.6 8.4 13.8 239 10103091SH119
THN3366SS316 59.5 24.6 25.6 8.4 13.8 239 10103091SH119
Heavy Duty, NEMA Type 4/4X Water/Dust-tight (Cont.) Approximate Dimensions in inches
Product Dimension Dimension Dimension W2 Dimension Dimension D2 Weight KO Figure D2
Number H W (Box) (W/ Handle) D (Box) (W/ Handle) (lbs) Drawing # Number D
W2
TH3361SSW 13.3 9.4 10.1 4.9 9.4 18 10103091SH109
TH3362MSS 19.3 9.4 14.1 5.0 10.1 23 10103091SH123
TH3362MSSW 19.3 9.4 14.1 5.0 10.1 23 10103091SH123
TH3362SS 19.3 9.4 10.1 5.2 9.6 23 10103091SH109
TH3362SS-BA 19.3 9.4 10.1 5.2 9.6 23 10103091SH109
H
TH3362SSW 19.3 9.4 10.1 5.2 9.6 22 10103091SH109
TH3363MSS 25.4 13.4 15.3 5.0 10.4 23 10103091SH128
TH3363SS 25.4 13.4 14.3 5.2 9.6 36 10103091SH113
TH3363SS-BA 25.4 13.4 14.3 5.2 9.6 36 10103091SH113
TH3363SSW 25.4 13.5 14.2 5.2 9.6 35 10103091SH113
TH3364MSS 35.1 14.4 16.3 5.0 10.4 45 10103091SH128
W
TH3364SS 35.1 14.5 15.5 5.2 9.6 49 10103091SH113
TH3364SS-BA 35.1 14.5 15.5 5.2 9.6 49 10103091SH113 Heavy Duty NEMA Type 4/4X
TH3364SSW 35.2 14.5 15.5 5.2 9.6 33 10103091SH113
TH3365MSS 59.4 24.5 25.6 7.9 14.4 206 10103091SH130
TH3365SS 59.5 24.6 25.6 8.4 13.8 131 10103091SH119
TH3366MSS 59.4 24.5 25.6 7.9 14.4 211 10103091SH130
TH3366SS 59.5 24.6 25.6 8.4 13.8 139 10103091SH119
TH4321SS 11.3 7.4 8.1 4.9 9.4 12 10103091SH109
TH4321SS-BA 11.3 7.4 8.1 4.9 9.4 12 10103091SH109
TH4321SSW 11.3 7.4 8.1 4.9 9.4 12 10103091SH109
TH4322SS 19.3 9.4 10.1 5.2 9.6 23 10103091SH109
TH4322SS-BA 19.3 9.4 10.1 5.2 9.6 23 10103091SH109
TH4322SSW 19.3 9.4 10.1 5.2 9.6 23 10103091SH109
TH4323SS 25.4 13.4 14.3 5.2 9.6 36 10103091SH113
TH4323SS-BA 25.4 13.4 14.3 5.2 9.6 36 10103091SH113
TH4323SSW 25.4 13.5 14.2 5.2 9.6 36 10103091SH113
TH4324SS 35.1 14.5 15.5 5.2 9.6 47 10103091SH113
TH4324SS-BA 35.1 14.5 15.5 5.2 9.6 47 10103091SH113
TH4324SSW 35.2 14.5 15.5 5.2 9.6 47 10103091SH113 No KO
TH4325SS 59.5 24.6 25.6 8.4 13.8 135 10103091SH119
TH4326SS 59.5 24.6 25.6 8.4 13.8 139 10103091SH119
THN2261SSDC 11.3 9.4 10.1 4.9 9.4 16 10103091SH109
THN2262SSDC 13.3 9.4 10.1 5.2 9.6 16 10103091SH109
THN2263SSDC 25.4 13.4 14.3 5.2 9.6 30 10103091SH113
THN3361MSS 19.3 9.4 14.1 5.0 10.1 22 10103091SH123
THN3361MSSW 19.3 9.4 14.1 5.0 10.1 22 10103091SH123
THN3361SS 11.3 9.4 10.1 4.9 9.4 16 10103091SH109
THN3361SS-BA 11.3 9.4 10.1 4.9 9.4 16 10103091SH109
THN3361SSCL 13.3 9.4 10.1 5.2 9.6 9 10103091SH109
THN3361SSW 11.3 9.4 10.1 4.9 9.4 19 10103091SH109
THN3362MSS 19.3 9.4 14.1 5.0 10.1 15 10103091SH123
THN3362SS 13.3 9.4 10.1 5.2 9.6 21 10103091SH109
THN3362SS-BA 13.3 9.4 10.1 5.2 9.6 21 10103091SH109
THN3362SSCL 13.3 9.4 10.1 5.2 9.6 21 10103091SH109
THN3362SSW 13.3 9.4 10.1 5.2 9.6 22 10103091SH109
THN3363MSS 25.4 13.4 15.3 5.0 10.4 20 10103091SH128
THN3363SS 25.4 13.4 14.3 5.2 9.6 36 10103091SH113
THN3363SS-BA 25.4 13.4 14.3 5.2 9.6 36 10103091SH113
THN3363SSW 25.4 13.5 14.2 5.2 9.6 36 10103091SH113
THN3364MSS 35.1 14.4 16.3 5.0 10.4 32 10103091SH128
THN3364SS 35.1 14.5 15.5 5.2 9.6 50 10103091SH113
THN3364SS-BA 35.1 14.5 15.5 5.2 9.6 50 10103091SH113
THN3364SSCL 35.1 14.5 15.5 5.2 9.6 32 10103091SH113
THN3364SSW 35.2 14.5 15.5 5.2 9.6 32 10103091SH113
THN3365MSS 47.9 24.5 25.6 7.9 14.4 110 10103091SH130
THN3365SS 48.0 24.6 25.6 8.4 13.7 239 10103091SH119
THN3366MSS 47.9 24.5 25.6 7.9 14.4 110 10103091SH130
THN3366SS 48.0 24.6 25.6 8.4 13.7 139 10103091SH119
Number H W (Box) (W/ Handle) D (Box) (W/ Handle) (lbs) Drawing # Number
TDT3321 37.0 12.0 12.8 8.3 11.2 47 10103091SH137
TDT3322 37.0 12.0 12.8 8.3 11.2 43 10103091SH137
TDT3323 37.0 12.0 12.8 8.3 11.2 48 10103091SH137
TDT3324 51.4 19.2 19.9 6.1 11.3 159 10103091SH138
TDT3325 74.7 25.3 26.2 8.9 14.1 163 10103091SH139
TDT3326 86.1 27.4 28.3 8.9 14.1 341 10103091SH139
TDT3327 58.9 28.1 29.3 20.5 25.6 275 10103091SH147
H
TDT3328 78.1 42.6 43.8 20.5 29.6 501 10103091SH146 No KO
TDT3361 37.0 12.0 12.8 8.3 11.2 42 10103091SH137
TDT3362 37.0 12.0 12.8 8.3 11.2 43 10103091SH137
TDT3363 37.0 12.0 12.8 8.3 11.2 62 10103091SH137
TDT3364 51.4 27.6 28.6 8.8 16.2 102 10103091SH138
TDT3365 74.7 25.3 26.2 8.9 14.1 274 10103091SH139
TDT3366 58.9 28.1 29.3 20.5 25.6 278 10103091SH144
TDT3367 58.9 28.1 29.3 20.5 25.6 278 10103091SH145
TDT3368 78.1 42.6 43.8 20.5 29.6 501 10103091SH146
W
Product Dimension Dimension Dimension W2 Dimension Dimension D2 Weight KO Figure Double Throw NEMA Type 3R
Number H W (Box) (W/ Handle) D (Box) (W/ Handle) (lbs) Drawing # Number
TC35361SS 25.7 11.9 12.7 5.5 11.4 60 10103091SH150
TC35362SS 25.7 11.9 12.7 5.5 11.4 60 10103091SH150
D2
TC35363SS 25.7 11.9 12.7 5.5 11.4 60 10103091SH150 W2 D
TC35364SS 39.8 19.6 20.3 6.5 11.7 105 10103091SH186 No KO
TC35365SS 37.9 19.6 20.3 6.5 14.1 185 10103091SH149
TC35366SS 67.0 24.1 25.3 9.0 14.0 195 10103091SH188
TC35367SS 63.3 27.4 28.4 8.9 14.1 230 10103091SH187
Double Throw, NEMA Type 4X (304 Stainless) TDT Approximate Dimensions in inches
Product Dimension Dimension Dimension W2 Dimension Dimension D2 Weight KO Figure
Number H W (Box) (W/ Handle) D (Box) (W/ Handle) (lbs) Drawing # Number
TDT3361SS 38.8 12.0 12.8 5.5 11.4 45 10103091SH148 W
TDT3362SS 38.8 12.0 12.8 5.5 11.4 45 10103091SH148
TDT3363SS 38.8 12.0 12.8 5.5 11.4 45 10103091SH148 No KO Double Throw NEMA Type 4X
TDT3364SS 53.3 19.6 20.3 6.5 11.6 100 10103091SH142
TDT3365SS 37.9 19.6 20.3 6.5 14.1 260 10103091SH149
Dimensions-Knockouts
Symbol A B C D E F G H J K L M N
9/32 1/2 1/2 1/2 1/2 1/2 3/4 3/4 1 1 2 2 2 1/ 2
Conduit
3/4 3/4 3/4 3/4 1 1 1 1/4 1 1/2 2 1/2 2 1/2 3
Size
(Inches) 1 1 1 1 1/4 1 1/2 2 3 3
1 1/4 1 1/2 1 1/ 2 2 2 1/2 3 1/2
References
Integrated SPD DEA-390, DEA-391, DEA-393, DEA-394
Wall Mounted DEA-300, DEA-320, DEA-391, DEA-392
1.331 [33.81]
5.064 [128.62]
0.312 [7.91] TYP
5.331 [135.41]
6.000 [152.40]
8.321 [211.36]
9.494 [241.15]
2.869 [72.87]
9.400 [238.76]
Product # T P M E * * AS = Full featured, with UL 1283 noise filtering and surge counter
ASNF = without UL 1283 noise filtering (Available 100kA per Mode) only
ASNC = without UL 1283 noise filtering, without surge counter
(Available 100kA per Mode) only
17.722 0.280
[450.130] 6.964
[ 7.112] HOLE [176.877]
17.382
0.340 (4 PLACES)
[441.494]
[8.636]
9.400
[238.755]
6.762
[171.751] TYP
2.638
[67.004] TYP
[182.922]
7.202
For GE MCC Distribution Equipment For GE Spectra Panel or Switch Board Distribution Equipment -
200 kA Symmetrical Fault Withstand 200 kA Symmetrical Fault Withstand
Panelboard, Lights, Alarm, Surge Counter, Form C Contacts Panelboard, Lights, Alarm, Surge Counter, Form C Contacts
Maximum Surge Current Product Number Maximum Surge Current Product Number
65kA per mode / 130kA per phase TPME120S06ME 65kA per mode / 130kA per phase TPME120S06PP
65kA per mode / 130kA per phase TPME120Y06ME 65kA per mode / 130kA per phase TPME120Y06PP
65kA per mode / 130kA per phase TPME220Y06ME 65kA per mode / 130kA per phase TPME220Y06PP
65kA per mode / 130kA per phase TPME277Y06ME 65kA per mode / 130kA per phase TPME277Y06PP
65kA per mode / 130kA per phase TPME480D06ME 65kA per mode / 130kA per phase TPME480D06PP
65kA per mode / 130kA per phase TPME347Y06ME 65kA per mode / 130kA per phase TPME347Y06PP
65kA per mode / 130kA per phase TPME240H06ME 65kA per mode / 130kA per phase TPME240H06PP
65kA per mode / 130kA per phase TPME240D06ME 65kA per mode / 130kA per phase TPME240D06PP
65kA per mode / 130kA per phase TPME240Y06ME 65kA per mode / 130kA per phase TPME240Y06PP
80kA per mode / 160kA per phase TPME120S08ME 80kA per mode / 160kA per phase TPME120S08PP
80kA per mode / 160kA per phase TPME120Y08ME 80kA per mode / 160kA per phase TPME120Y08PP
80kA per mode / 130kA per phase TPME220Y08ME 80kA per mode / 130kA per phase TPME220Y08PP
80kA per mode / 160kA per phase TPME277Y08ME 80kA per mode / 160kA per phase TPME277Y08PP
80kA per mode / 160kA per phase TPME480D08ME 80kA per mode / 160kA per phase TPME480D08PP
80kA per mode / 160kA per phase TPME347Y08ME 80kA per mode / 160kA per phase TPME347Y08PP
80kA per mode / 160kA per phase TPME240H08ME 80kA per mode / 160kA per phase TPME240H08PP
80kA per mode / 160kA per phase TPME240D08ME 80kA per mode / 160kA per phase TPME240D08PP
80kA per mode / 160kA per phase TPME240Y08ME 80kA per mode / 160kA per phase TPME240Y08PP
100kA per mode / 200kA per phase TPHE120S10ME 100kA per mode / 200kA per phase TPHE120S10PP
100kA per mode / 200kA per phase TPHE120Y10ME 100kA per mode / 200kA per phase TPHE120Y10PP
100kA per mode / 200kA per phase TPHE220Y10ME 100kA per mode / 200kA per phase TPHE220Y10PP
100kA per mode / 200kA per phase TPHE277Y10ME 100kA per mode / 200kA per phase TPHE277Y10PP
100kA per mode / 200kA per phase TPHE480D10ME 100kA per mode / 200kA per phase TPHE480D10PP
100kA per mode / 200kA per phase TPHE347Y10ME 100kA per mode / 200kA per phase TPHE347Y10PP
100kA per mode / 200kA per phase TPHE240H10ME 100kA per mode / 200kA per phase TPHE240H10PP
100kA per mode / 200kA per phase TPHE240D10ME 100kA per mode / 200kA per phase TPHE240D10PP
100kA per mode / 200kA per phase TPHE240Y10ME 100kA per mode / 200kA per phase TPHE240Y10PP
150kA per mode / 300kA per phase TPHE120S15ME 150kA per mode / 300kA per phase TPHE120S15PP
150kA per mode / 300kA per phase TPHE120Y15ME 150kA per mode / 300kA per phase TPHE120Y15PP
150kA per mode / 300kA per phase TPHE220Y15ME 150kA per mode / 300kA per phase TPHE220Y15PP
150kA per mode / 300kA per phase TPHE277Y15ME 150kA per mode / 300kA per phase TPHE277Y15PP
150kA per mode / 300kA per phase TPHE480D15ME 150kA per mode / 300kA per phase TPHE480D15PP
150kA per mode / 300kA per phase TPHE347Y15ME 150kA per mode / 300kA per phase TPHE347Y15PP
150kA per mode / 300kA per phase TPHE240H15ME 150kA per mode / 300kA per phase TPHE240H15PP
150kA per mode / 300kA per phase TPHE240D15ME 150kA per mode / 300kA per phase TPHE240D15PP
150kA per mode / 300kA per phase TPHE240Y15ME 150kA per mode / 300kA per phase TPHE240Y15PP
200kA per mode / 400kA per phase TPHE120S20ME 200kA per mode / 400kA per phase TPHE120S20PP
200kA per mode / 400kA per phase TPHE120Y20ME 200kA per mode / 400kA per phase TPHE120Y20PP
200kA per mode / 400kA per phase TPHE220Y20ME 200kA per mode / 400kA per phase TPHE220Y20PP
200kA per mode / 400kA per phase TPHE277Y20ME 200kA per mode / 400kA per phase TPHE277Y20PP
200kA per mode / 400kA per phase TPHE480D20ME 200kA per mode / 400kA per phase TPHE480D20PP
200kA per mode / 400kA per phase TPHE347Y20ME 200kA per mode / 400kA per phase TPHE347Y20PP
200kA per mode / 400kA per phase TPHE240H20ME 200kA per mode / 400kA per phase TPHE240H20PP
200kA per mode / 400kA per phase TPHE240D20ME 200kA per mode / 400kA per phase TPHE240D20PP
200kA per mode / 400kA per phase TPHE240Y20ME 200kA per mode / 400kA per phase TPHE240Y20PP
300kA per mode / 600kA per phase TPHE120S30ME 300kA per mode / 600kA per phase TPHE120S30PP
300kA per mode / 600kA per phase TPHE120Y30ME 300kA per mode / 600kA per phase TPHE120Y30PP
300kA per mode / 600kA per phase TPHE220Y30ME 300kA per mode / 600kA per phase TPHE220Y30PP
300kA per mode / 600kA per phase TPHE277Y30ME 300kA per mode / 600kA per phase TPHE277Y30PP
300kA per mode / 600kA per phase TPHE480D30ME 300kA per mode / 600kA per phase TPHE480D30PP
300kA per mode / 600kA per phase TPHE347Y30ME 300kA per mode / 600kA per phase TPHE347Y30PP
300kA per mode / 600kA per phase TPHE240H30ME 300kA per mode / 600kA per phase TPHE240H30PP
300kA per mode / 600kA per phase TPHE240D30ME 300kA per mode / 600kA per phase TPHE240D30PP
300kA per mode / 600kA per phase TPHE240Y30ME 300kA per mode / 600kA per phase TPHE240Y30PP
Specifications
Operating Frequency: 50/60 Hz
Connection: 6 to 2/0 Conductors, Parallel Connected
Operating Temperature: -40C to +65C
Operating Humidity: 0% to 95% Non-Condensing
Weight: 9X - 30 lbs., 12X - 52 lbs.
9.000
[228.60]
9.000
10.440 [228.6]
[265.18]
9.810
[249.174]
0.042
0.588 [1.067]
[14.94]
1.719 1.719
[43.67] [43.675]
0.344 [8.74] 0.344 [8.738]
7.375
7.375 [187.338]
[187.34] 10.000
10.000 [254]
[254.00] 12.6255
[320.69]
12.625
15.400
[320.69]
[391.16]
15.400
[391.16]
20.250 6.023
21.500 [514.350] [152.984]
[546.100] 6.023
[152.984]
9.000
9.000 [228.600]
7.042
6.412 [228.600] [178.867]
[162.865] 9.810
10.440 [249.174]
[265.176]
0.588
1.617 2.247 6.609
[14.935]
[41.072] 7.239 [57.074] [167.869]
[183.871] 13.624
14.254 [346.050]
[362.052]
2.389
2.389 [60.693]
[60.693]
0.344 [8.738]
7.085
[179.95] 7.085
6.810 [179.954]
[172.97]
6.333 12.560 5.390 6.333 6.810
0.711 [172.969]
[160.86] [319.02] [136.91] [160.858]
[18.06] 11.940 5.390 0.711
[303.276] [136.906] [18.059]
6.899 6.074
[175.23] [154.28]
8.030 6.074
6.274 8.030
[203.96] 8.635 [154.280]
21.500 [159.360]
[219.33] [203.962] 8.635
[546.10]
[219.329]
20.280 7.624 11.635
[515.11] [193.65] 1.400 20.280 7.624 [295.529]
[35.56] [515.112] [193.650]
1.400
[35.560]
24.000 3.176
[609.60] [80.67] 24.000 3.176
[609.600] [80.672]
7.246 [184.048]
7.246
[184.044]
24.743
[628.47] 24.743
25.440 [628.472]
[646.18]
Note: Replace XXXX in Product Number with nomenclature for Nominal Voltage (Volts RMS).
Note: Replace XXXX in Product Number with nomenclature for Nominal Voltage (Volts RMS).
Note: Replace XXXX in Product Number with nomenclature for Nominal Voltage (Volts RMS).
MCOV %
Nominal System Max. Maximum Surge
Voltage Voltage
Continuous Current Capacity
Operating
(Volts RMS) Configuration Voltage Exposure
Level Per Mode Per Phase
ME 120S 120/240 1 Ph, 3 W + G 125% 06 ME 65kA 130kA
HE 120Y 120Y/208 3 Ph, 4 W + G 125% 08 ME 80kA 160kA
220Y 220Y/380 3 Ph, 4 W + G 145% 10 ME 100kA 200kA
240D 240 Delta 3 Ph, 3 W + G 115% 12 HE 125kA 250kA
240H 120/240 Delta HL 3 Ph, 4 W + G 115% 15 HE 150kA 300kA
240Y 240Y/415 3 Ph, 4 W + G 130% 20 HE 200kA 400kA
277Y 277Y/480 3 Ph, 4 W + G 115% 25 HE 250kA 500kA
347Y 347Y/600 3 Ph, 4 W + G 115% 30 HE 300kA 600kA
480D 480 Delta 3 Ph, 3 W + G 170%
Phase Rating = (L-N + L-G) Product # Example
Also available in 600D configurations. For details, please TPHE277Y15BX24WF
contact GE Power Quality Customer Service at
277Y/480 V, 3 Ph, 4 W + G
800 637 1738.
150kA per mode
Flush mounted, display access
15.330
[389.38]
0.282 14.759 12.015
[ 7.16] HOLES [374.88] [305.18]
(8 PLACES) 13.478
[342.34]
1.852 0.440
0.571
8.978 [47.04] [14.50] [ 11.18] HOLE
[228.04] (2 PLACES)
0.625
[15.87]
18.759
[476.48]
16.000 19.330
[406.40] [490.98]
15.478
[393.14]
Wall Mount Tranquell ME - 200kA Symmetrical Fault Withstand Lights, Alarm, Surge Counter, Form C Contacts
Maximum Surge Current Enclosure Type Product Number
65kA per mode / 130kA per phase NEMA 12 Flush TMEXXXX065WMN12F
80kA per mode / 160kA per phase NEMA 12 Flush TMEXXXX080WMN12F
100kA per mode / 200kA per phase NEMA 12 Flush TMEXXXX100WMN12F
65kA per mode / 130kA per phase NEMA 12 Surface, Integral Disconnect TMEXXXX065WMN1
80kA per mode / 160kA per phase NEMA 12 Surface, Integral Disconnect TMEXXXX080WMN1
100kA per mode / 200kA per phase NEMA 12 Surface, Integral Disconnect TMEXXXX100WMN1
65kA per mode / 130kA per phase NEMA 12 Surface TMEXXXX065WMN12S
80kA per mode / 160kA per phase NEMA 12 Surface TMEXXXX080WMN12S
100kA per mode / 200kA per phase NEMA 12 Surface TMEXXXX100WMN12S
65kA per mode / 130kA per phase NEMA 4 Painted Steel Surface TMEXXXX065WMN4S
80kA per mode / 160kA per phase NEMA 4 Painted Steel Surface TMEXXXX080WMN4S
100kA per mode / 200kA per phase NEMA 4 Painted Steel Surface TMEXXXX100WMN4S
65kA per mode / 130kA per phase NEMA 4X Fiberglass, Integral Disconnect TMEXXXX065WMN4
80kA per mode / 160kA per phase NEMA 4X Fiberglass, Integral Disconnect TMEXXXX080WMN4
100kA per mode / 200kA per phase NEMA 4X Fiberglass, Integral Disconnect TMEXXXX100WMN4
65kA per mode / 130kA per phase NEMA 4X Stainless Steel TMEXXXX065WMN4X
80kA per mode / 160kA per phase NEMA 4X Stainless Steel TMEXXXX080WMN4X
100kA per mode / 200kA per phase NEMA 4X Stainless Steel TMEXXXX100WMN4X
Note: Replace XXXX in Product Number with nomenclature for Nominal Voltage (Volts RMS).
Wall Mount Tranquell HE - 200kA Symmetrical Fault Withstand Lights, Alarm, Surge Counter, Form C Contacts
Maximum Surge Current Enclosure Type Product Number
100kA per mode / 200kA per phase NEMA 12 Flush THEXXXX100WMN12F
150kA per mode / 300kA per phase NEMA 12 Flush THEXXXX150WMN12F
200kA per mode / 400kA per phase NEMA 12 Flush THEXXXX200WMN12F
300kA per mode / 600kA per phase NEMA 12 Flush THEXXXX300WMN12F
100kA per mode / 200kA per phase NEMA 12 Surface, Integral Disconnect THEXXXX100WMN1
150kA per mode / 300kA per phase NEMA 12 Surface, Integral Disconnect THEXXXX150WMN1
200kA per mode / 400kA per phase NEMA 12 Surface, Integral Disconnect THEXXXX200WMN1
300kA per mode / 600kA per phase NEMA 12 Surface, Integral Disconnect THEXXXX300WMN1
100kA per mode / 200kA per phase NEMA 12 Surface THEXXXX100WMN12S
150kA per mode / 300kA per phase NEMA 12 Surface THEXXXX150WMN12S
200kA per mode / 400kA per phase NEMA 12 Surface THEXXXX200WMN12S
300kA per mode / 600kA per phase NEMA 12 Surface THEXXXX300WMN12S
100kA per mode / 200kA per phase NEMA 4 Painted Steel Surface THEXXXX100WMN4S
150kA per mode / 300kA per phase NEMA 4 Painted Steel Surface THEXXXX150WMN4S
200kA per mode / 400kA per phase NEMA 4 Painted Steel Surface THEXXXX200WMN4S
300kA per mode / 600kA per phase NEMA 4 Painted Steel Surface THEXXXX300WMN4S
100kA per mode / 200kA per phase NEMA 4X Fiberglass, Integral Disconnect THEXXXX100WMN4
150kA per mode / 300kA per phase NEMA 4X Fiberglass, Integral Disconnect THEXXXX150WMN4
200kA per mode / 400kA per phase NEMA 4X Fiberglass, Integral Disconnect THEXXXX200WMN4
300kA per mode / 600kA per phase NEMA 4X Fiberglass, Integral Disconnect THEXXXX300WMN4
100kA per mode / 200kA per phase NEMA 4X Stainless Steel THEXXXX100WMN4X
150kA per mode / 300kA per phase NEMA 4X Stainless Steel THEXXXX150WMN4X
200kA per mode / 400kA per phase NEMA 4X Stainless Steel THEXXXX200WMN4X
300kA per mode / 600kA per phase NEMA 4X Stainless Steel THEXXXX300WMN4X
Note: Replace XXXX in Product Number with nomenclature for Nominal Voltage (Volts RMS).
Product # WM N
NEMA
Suffix Description Enclosure Mounting Disconnect
1 Painted Steel 1 Surface Yes
12S Painted Steel 12 Surface No
Product # Example
THE277Y150WMN12S 12F Painted Steel 12 Flush No
4 Fiberglass 4X Surface Yes
4S Painted Steel 4 Surface No
4X Stainless Steel 4X Surface No
Introduction
Recommended installation locations are primary and secondary
distribution and point of use levels. Designed for distribution and
point of use locations, but rated for service entrance, the
Tranquell HE and ME with enhanced thermal protection has
been third-party tested to ANSI/IEEE C3 10kA 8x20s impulses.
The entire Tranquell HE and ME line-up has been engineered to
the highest standards and is designed for rigorous duty and long
life, as evidenced in our outstanding minimum repetitive surge
current capacity test results.
These devices are available in a standard NEMA 12 enclosure.
Optional enclosure types from NEMA 12 NEMA 4x include flush
mount, surface mount, fiberglass and stainless steel.
These units have been tested to surge current ratings per NEMA
LS-1, up to 200kA per mode, 400kA per phase. Standard features
include a surge counter, audible alarm, indicating lights, dry
contacts, and an integral surge rated disconnect. Rating options
Specifications
range from 65kA 300kA per mode, 130kA 600kA per phase.
Operating Frequency 50/60 Hz
GE engineers design and build transient voltage surge suppres- Connection 6 to 2/0 Conductors, Parallel Connected
sors in our state-of-the-art lab and production facilities. Extensive Operating Temperature -40 F to 140 F (-40 C to +65 C)
testing is performed at GE and third-party test labs across North Operating Humidity 0% to 95% Non-Condensing
America. Production is carried out at our factory in Bonham, Texas
Weight NEMA Enclosure Suffix:
utilizing Six Sigma, ISO 9001 methodologies and lean
1 63 lbs. (28.5 kg)
manufacturing processes.
4 56 lbs. (25.4 kg)
4S, 12S, 12F 44 lbs. (20.0 kg)
4X 50 lbs. (22.7 kg)
Features and Benefits
UL 1449 3rd Edition, September 2009, cUL
UL 1283 noise filtering. The TVSS device EMI-RFI noise rejection
or attenuation value is measured in accordance with the
procedures outlined in NEMA LS 1-1992 (R2000)/MILSTD-220B.
Attenuation is -50db minimum @ 100kHz.
UL tested to 200,000 amperes symmetrical withstand
Integral surge rated disconnect
Tranquell ME device is capable of surviving a minimum of
5,000 category C3 impulses (10kA, 20kV) per mode
Tranquell HE device is capable of surviving a minimum of
20,000 category C3 impulses (10kA, 20kV) per mode
Thermally protected MOVS eliminate the need for additional
upstream fuses
NO/NC Form C dry type contacts for remote monitoring
Green status indicating lights, red service light
Audible alarm with test/disable feature
Standard LCD surge counter
10 year limited warranty (standard),
20 year limited warranty (optional)
12.000
[304.80] 20.000
[508.00]
12.015
[305.18] 12.651
[321.34]
0.440
[ 11.18] HOLE
(2 PLACES)
0.625
[15.87]
26.500 24.000
[673.10] [609.60]
24.000 25.500
[609.60] [647.70]
0.625
[15.87]
9.276 1.250
[235.61] [31.75] 0.440
10.750
[273.05] [ 11.18]
(2 PLACES)
12.000 9.912 21.500
[251.76] [546.10]
[304.80]
15.330
0.380
[389.38] [ 9.65] HOLE
14.759 (4 PLACES)
0.282
[ 7.16] HOLES [374.88] 9.226 10.399
(8 PLACES) 13.478 [234.33] [264.14]
[342.34]
1.852 0.571
8.978 [47.04] [14.50]
[228.04]
18.759
[476.48]
19.118 17.659
19.330
[485.61] [448.53]
16.000
[406.40] [490.98]
15.478
[393.14]
3.852
[97.84]
0.571
[14.50]
1.471
[37.36]
1.475
15.330 [37.46]
6.440 [389.38] 11.999
[163.58] 6.439 [304.77]
[163.56]
8.978
[228.04]
9.226
[234.33]
12.000
[304.80]
Wall Mount Tranquell ME - 200kA Symmetrical Fault Withstand Lights, Alarm, Surge Counter, Form C Contacts
Maximum Surge Current Enclosure Type Product Number
65kA per mode / 130kA per phase NEMA 12 Flush TPMEXXXX06WMN12F
80kA per mode / 160kA per phase NEMA 12 Flush TPMEXXXX08WMN12F
100kA per mode / 200kA per phase NEMA 12 Flush TPMEXXXX10WMN12F
65kA per mode / 130kA per phase NEMA 12 Surface, Integral Disconnect TPMEXXXX06WMN1
80kA per mode / 160kA per phase NEMA 12 Surface, Integral Disconnect TPMEXXXX08WMN1
100kA per mode / 200kA per phase NEMA 12 Surface, Integral Disconnect TPMEXXXX10WMN1
65kA per mode / 130kA per phase NEMA 12 Surface TPMEXXXX06WMN12S
80kA per mode / 160kA per phase NEMA 12 Surface TPMEXXXX08WMN12S
100kA per mode / 200kA per phase NEMA 12 Surface TPMEXXXX10WMN12S
65kA per mode / 130kA per phase NEMA 4 Painted Steel Surface TPMEXXXX06WMN4S
80kA per mode / 160kA per phase NEMA 4 Painted Steel Surface TPMEXXXX08WMN4S
100kA per mode / 200kA per phase NEMA 4 Painted Steel Surface TPMEXXXX10WMN4S
65kA per mode / 130kA per phase NEMA 4X Fiberglass, Integral Disconnect TPMEXXXX06WMN4
80kA per mode / 160kA per phase NEMA 4X Fiberglass, Integral Disconnect TPMEXXXX08WMN4
100kA per mode / 200kA per phase NEMA 4X Fiberglass, Integral Disconnect TPMEXXXX10WMN4
65kA per mode / 130kA per phase NEMA 4X Stainless Steel TPMEXXXX06WMN4X
80kA per mode / 160kA per phase NEMA 4X Stainless Steel TPMEXXXX08WMN4X
100kA per mode / 200kA per phase NEMA 4X Stainless Steel TPMEXXXX10WMN4X
Note: Replace XXXX in Product Number with nomenclature for Nominal Voltage (Volts RMS).
Wall Mount Tranquell HE - 200kA Symmetrical Fault Withstand Lights, Alarm, Surge Counter, Form C Contacts
Maximum Surge Current Enclosure Type Product Number
100kA per mode / 200kA per phase NEMA 12 Flush TPHEXXXX10WMN12F
150kA per mode / 300kA per phase NEMA 12 Flush TPHEXXXX15WMN12F
200kA per mode / 400kA per phase NEMA 12 Flush TPHEXXXX20WMN12F
300kA per mode / 600kA per phase NEMA 12 Flush TPHEXXXX30WMN12F
100kA per mode / 200kA per phase NEMA 12 Surface, Integral Disconnect TPHEXXXX10WMN1
150kA per mode / 300kA per phase NEMA 12 Surface, Integral Disconnect TPHEXXXX15WMN1
200kA per mode / 400kA per phase NEMA 12 Surface, Integral Disconnect TPHEXXXX20WMN1
300kA per mode / 600kA per phase NEMA 12 Surface, Integral Disconnect TPHEXXXX30WMN1
100kA per mode / 200kA per phase NEMA 12 Surface TPHEXXXX10WMN12S
150kA per mode / 300kA per phase NEMA 12 Surface TPHEXXXX15WMN12S
200kA per mode / 400kA per phase NEMA 12 Surface TPHEXXXX20WMN12S
300kA per mode / 600kA per phase NEMA 12 Surface TPHEXXXX30WMN12S
100kA per mode / 200kA per phase NEMA 4 Painted Steel Surface TPHEXXXX10WMN4S
150kA per mode / 300kA per phase NEMA 4 Painted Steel Surface TPHEXXXX15WMN4S
200kA per mode / 400kA per phase NEMA 4 Painted Steel Surface TPHEXXXX20WMN4S
300kA per mode / 600kA per phase NEMA 4 Painted Steel Surface TPHEXXXX30WMN4S
100kA per mode / 200kA per phase NEMA 4X Fiberglass, Integral Disconnect TPHEXXXX10WMN4
150kA per mode / 300kA per phase NEMA 4X Fiberglass, Integral Disconnect TPHEXXXX15WMN4
200kA per mode / 400kA per phase NEMA 4X Fiberglass, Integral Disconnect TPHEXXXX20WMN4
300kA per mode / 600kA per phase NEMA 4X Fiberglass, Integral Disconnect TPHEXXXX30WMN4
100kA per mode / 200kA per phase NEMA 4X Stainless Steel TPHEXXXX10WMN4X
150kA per mode / 300kA per phase NEMA 4X Stainless Steel TPHEXXXX15WMN4X
200kA per mode / 400kA per phase NEMA 4X Stainless Steel TPHEXXXX20WMN4X
300kA per mode / 600kA per phase NEMA 4X Stainless Steel TPHEXXXX30WMN4X
Note: Replace XXXX in Product Number with nomenclature for Nominal Voltage (Volts RMS).
Product # T P W M N
ME 120S 120/240 1 Ph, 3W + G 900 800 700 1200 125% Exposure Level Per Mode Per Phase
HE 120Y 120Y/208 3 Ph, 4W + G 900 800 700 1200 125% 06 ME 65kA 130kA
220Y 220Y/380 3 Ph, 4W + G 1500 1200 1200 2000 145% 08 ME 80kA 160kA
240D 240 Delta 3 Ph, 4W 1200 1800 196% 10 ME 100kA 200kA
240H 120/240 Delta HL 3 Ph, 4W + G 1000 1200 800 1200 700 2000 2200 115% 12 HE 125kA 250kA
240Y 240Y/415 3 Ph, 4W + G 1500 1200 1200 2000 130% 15 HE 150kA 300kA
277Y 277Y/480 3 Ph, 4W + G 1500 1200 1200 2000 115% 20 HE 200kA 400kA
347Y 347Y/600 3 Ph, 4W + G 1500 ---- 1500 ---- 1500 2500 ---- 115% 25 HE 250kA 500kA
480D 480 Delta 3 Ph, 4W ---- ---- 1800 ---- ---- 3000 ---- 198% 30 HE 300kA 600kA
Phase Rating = (L-N + L-G)
Also available in 600D configurations. For details, please contact GE Power Quality
Customer Service at 800 637 1738.
Product # Example
TPHE277Y15WMN12S
277Y/480 V, 3 Ph, 4 W + G NEMA
Suffix Description Mounting Disconnect
150kA per mode Enclosure
Surface mount enclosure 1 Painted Steel 1 Surface Yes
without disconnect 12S Painted Steel 12 Surface No
Painted steel 12F Painted Steel 12 Flush No
4 Fiberglass 4X Surface Yes
4S Painted Steel 4 Surface No
4X Stainless Steel 4X Surface No
Specifications
Operating Frequency: 50/60 Hz
Connection: 10 AWG Conductors, Parallel Connected
Operating Temperature: -40C to +65C
Operating Humidity: 0% to 95% Non-Condensing
Weight: (TME) 19 lbs., (TLE) 11.4 lbs.
TME TLE
4.00
3/4" N.P.T.
6.75
6.25
7.50
6.25
4.37
2.85
1.55
6.00
Note: Replace XXXX in Product Number with nomenclature for Nominal Voltage (Volts RMS).
Product # WM
Specifications
UL1449, 3rd edition (September 2009) 2.00
2.82
71.8
50.7
UL type 2 device Microswitch
**Wiring
Wiring Configuration
Configuration Diagrams
Diagrams (NOTE: Shown(NOTE
with no power applied)
: Shown with no power applied)
SINGLE SPLIT 3 PHASE DELTA / 3 PHASE HIGH LEG DELTA /
PHASE PHASE 3 PHASE WYE, COMMON N/G 3 PHASE WYE, PLUS N-G
L L1 L2 L1 L2 L3 L1 L2 L3
G/N
G/N G/N
N
**Electrical
** ElectricalVoltage Configurations
Voltage Configurations
L L1 L1 L1 L3 NOTE: GEs Tranquell Series SPD
DIN Rail mount devices are tested
L2
N
N for safe operation without any
N dedicated overcurrent protection,
L2 L1 when correctly matched to the
N L2 L3 L2 power system parameters.
L3
G G G G A gG 160 Amp NH Fuse may be
chosen to meet other requirements
FIGURE A FIGURE B FIGURE C FIGURE D FIGURE E in an IEC application. Consult local
Single Phase Split Phase 3 Phase Wye 3 Phase Delta 3 Phase Delta Hi-Leg codes and standards for appropriate
2 Wire + Ground 3 Wire + Ground 4 Wire + Ground 3 Wire + Ground 4 Wire + Ground fuse sizing.
Introduction
The GE 427 patented 5 Pin Protection Block Assembly is equipped
with a multi-layered printed circuit board, providing a connector-
ized interface for cable assemblies. It accommodates 25, 50 or
100 pair cable. It is used in many applications, including: central
offices, remote switching sites, customer premises and building
entrances, to protect telephone and voice/data lines.
When wiring cabinets with conventional wire wrap blocks each
block becomes a different part number and causes difficulty for
OEMs who have to inventory parts.
The same GE 427 Protection Block Assembly is used in every
position of a cabinet or mainframe. The cables are now treated as
less expensive parts and are stocked by length and mating con-
nector type. Manual labor, in running cables and making Protection Block Assembly
wire wrap connections, is reduced significantly by employing
GE Connectorized Block Assemblies.
Benefits
Provides maximum reliability by eliminating all wire wraps
Provides the high quality installation of a protection block
Provides additional flexibility for equipment installations
Easily serviceable in the field
Eliminates the need for wire wrapping
Allows connectorization into many different applications and
greatly reduces installation, labor and repair costs
All cables connected to this unit can be removed, permitting
specific cable change out or change out of the entire protection
block assembly. This allows the protected equipment to quickly
be put back into service.
Covered by a two year limited product warranty
Specifications
Voltage Class: 600 V
BIL rating: 10 kV
Primary Currents: 10 to 5000 amps
How to Order
Q-Line
Thermal Magnetic Circuit Breakers
Molded-Case Switches
The product number as shown in the following pages includes the
complete breaker or switch. TQD and TJD breakers are complete
with Cu/Al line and load lugs.
E 150 Line
Thermal Magnetic Circuit Breakers
Magnetic Circuit Breakers
Molded Case Switches
The product numbers as shown in the following pages include the
complete breaker or switch. All devices listed come with Cu/Al line
and load lugs. If line lugs are not required on a breaker, eliminate
WL from product number; for molded case switches see page
6-3. Unless otherwise noted, all circuit breakers are UL listed in
File E11592. Molded case switches are UL listed in File E57546.
J 600 Line
Thermal Magnetic Circuit Breakers
Magnetic Circuit Breakers
Molded Case Switches Q-Line Thermal Magnetic Circuit Breakers
These breakers are available with either noninterchangeable trip and Molded-Case Switches
(designated Type TJJ) or interchangeable trip (designated Type
TJK and THJK). Type TJJ product numbers include frame, trip,
Cu/Al line, and load lugs factory assembled. If line lugs are not
required on the breaker, eliminate WL from product number, and
Tri-Break Line
subtract price of line lugs from price of complete breaker.
Integrally Fused Thermal Magnetic Circuit Breakers
TJK breakers are available in two frames, 400 ampere frame Integrally Fused Magnetic Circuit Breakers
(125 to 400 amperes) and 600 ampere frame (250 to 600 Integrally Fused Molded Case Switches
amperes). Trip units are not interchangeable between frames.
These breakers are available in three types. Type TB1 (15-100
Complete Circuit Breaker price includes frame, trip unit, Cu/Al amperes) product numbers include frame, trip, line and load
line, and load lugs. Unit will be shipped unassembled unless order lugs, and current limiters all factory assembled. TB6 (300 to 600
specifies must be factory assembled. If line lugs are not amperes) and TB8 (600 to 800 amperes) include frame, trip and
required, eliminate WL from product number and subtract price limiters, factory assembled, but do not include line or load lugs.
of line lugs from price of complete breaker. If line and load lugs are required, order separately. Unless other-
To order the frame, trip, and lugs separately, select the required wise noted, TB1, TB6, and TB8 breaker components are UL
components from table. Magnetic breakers must be ordered as listed in File E42263. Fused molded case switches are UL
components. A complete breaker consists of frame, trip, and one listed in File E57546.
line and one load lug per pole. Mag-Break Line
Price of ordering Complete Circuit Breaker vs. frame, trip, and Magnetic only circuit breakers (motor circuit protectors)
line and load lugs separately is the same. These breakers are available only with noninterchangeable
Molded case switches can also be ordered as complete units adjustable magnetic trip, in frame Types E, F, J, K, and Tri-Break.
(designated Type TJK---Y) or as separate components. They are All breakers are shipped factory assembled, complete with Cu/Al
UL listed only as complete units. To indicate required lugs, see line and load lugs.
page 6-3. All magnetic only circuit breakers and limiters are UL Component
Unless otherwise noted, all circuit breakers are UL listed in File E Recognized in Files E11592 and E66390, respectively, unless
11592. Molded case switches are UL listed in File E57546. otherwise noted.
Spectra RMS
Circuit Breakers
Determine the required breaker frame, IC rating, and load
requirements. Select frame, trip unit (rating plug), and lug,
if required, product numbers from the tables on pages 6-45
to 6-53. For Spectra breakers with microEntelliGuard Trip
Units refer to pages 6-54 through 6-61. Select field-mounted
internal accessory product numbers, if required, on pages 6-67
and 6-68. Select field-mounted external accessory product
numbers, if required, on pages 6-95 through 6-106 and pages
6-62 to 6-66 for Spectra breakers with microEntelliGuard
Trip Units. Order as separate items.
Mag-Break Motor Circuit Protectors
Determine the required frame and ampere requirements.
Select frame, trip unit (rating plug), and lug, if required,
product numbers from the table on pages 6-91 through 6-92.
Select accessories as noted above for circuit breakers. The Spectra Circuit Breakers
same accessories are used with both circuit breakers and and Molded Case Switches
motor circuit protectors. Order as separate items.
Molded Case Switches
Determine the required frame and ampere requirements. Molded Case Circuit Breaker and Switch Terminal
Select frame and lug, if required, product numbers from Configuration Code
the table on page 6-90. Rating plugs are not used. Select
Order standard Cu/Al lugs by using suffix codes presented. Order
accessories as noted above for circuit breakers. Internal
lugs separately if special lugs are required. For optional lugs, see
accessories do not require dummy trips. The same
pages 6-103 and 6-104.
accessories are used with both circuit breakers and molded
case switches. Order as separate items. Suffix
Breaker/Switch
Unless otherwise noted, all circuit breakers are UL listed in File E Type Blank WL XL X2 LL
to 6-106.
Spectra RMS Breakerspages 6-66 to 6-67 and 6-94 to
6-106.
Spectra RMS Breakers with microEntelliGuard Trip Units
pages 6-62 to 6-68, and 6-94 to 6-106.
1Installation of accessories in molded case switches requires dummy trip; see page
6-44 for information. Dummy trip not required for Tri-Break or Q-Line molded
case switches.
Features
Spectra RMS Molded Case Circuit Breakers
SE150, SF250, SG600, and SK1200 circuit breaker frames have a
digital, solid-state, rms sensing trip system with field installable,
front-mounted rating plugs to establish or change the breaker
ampere rating. Adjustable instantaneous with tracking short-time
is standard on all frames including SE150. The trip system uses
digital sampling to determine the rms value of sinusoidal and
nonsinusoidal currents.
THHQL
THHQB 15-30 1 120 22 3 9/32 1 2 3/8 10
...GF
THQL
THQB 15-20 1 120/240 10 3 9/32 1 2 3/8 10
THQC
...AF
THHQL
THHQB 15-20 1 120/240 22 3 9/32 1 2 3/8 10
...AF
1 UL listed as HACR (heating, air conditioning and refrigeration).
2
Not UL listed.
J600 (UL File E-11592; TJJ, Fixed Thermal Magnetic Trip Unit; TJK, THJK: Interchangeable Thermal Mag. Trip Unit; CSA LR 40350)
16 lb/1
TJC 400-600 3 600 42 30 22 10 1/8 8 1/4 3 13/16 3 13/16 3 13/16 1 3/8 1 3/16
17 1/2 lb/1
1UL listed with poles in series for 500 Vdc ungrounded battery applications. 5UL/CSA listed for 10kA @ 347 Vac (TED) and 18kA @ 347V (THED).
2UL listed as HACR (heating, air conditioning, and refrigeration). Rated 10kA @ 480V but not UL listed.
315-50A UL listed as HID (high intensity discharge). 6UL listed 10kA, GE tested to 20kA.
410 amp not UL listed, rated 5kA @ 120V, 240V and 480V 7TED, 3P, 600V, 15A breaker is obsolete. (TED136015WL & THED136015WL)
8Per UL 489, interrupting capacities are not shown on product label.
IEC/JIS Ratings
Solid-State with Interchangeable Trip Unit (Rating Plug)
Japanese Industry Standard
IEC 947-2 Interruption Capacity kA Interruption Capacity kA
Circuit 220-240 Vac 380-415 Vac 500 Vac 690 Vac Vac
Breaker Ampere No.
Type Rating Poles Icu I cs I cu I cs I cu I cs I cu I cs 220-240 380-415 500 690
SE150 Current Limiting, 15-32A
2
SED 18 9 10 5 18 10
3 4 4 4
15-32
2
SEH 65 33 15 10 65 15
3 6 6 6
2
SEL 100 50 20 15 100 20
3 8 8 3 3 8 3
15-32
2
SEP
3
200 100 20 20
10 10 5 5
200 20
10 5
SE
SE150 Current Limiting, 40-160A
2
SED 18 9 14 7 18 14
3 14 7 14
40-160
2
SEH 65 33 35 17 65 25
3 25 12 18
2
SEL 100 50 65 33 100 65
3 40 20 5 5 25 5
40-160
2
SEP 200 100 100 50 200 100
3 50 25 10 5 65 10
SF250 Current Limiting
2
SFH 70-250 65 33 35 17 65 25
3 25 12 18
2
SFL 100 50 65 33 100 65
3 40 20 14 7 25 14
70-250
2 SF
SFP 200 100 100 50 200 100
3 65 33 18 9 65 18
SG600 Current Limiting
SGH11 65 33 25 13 18 9 65 25 18
SGL11 60-150 3 100 50 65 33 35 18 14 7 100 65 35 22
SGP11 200 100 100 50 50 25 18 9 200 100 65 35
2
SGH4 65 33 25 13 65 25
3 18 9 18
2
SGL4 125-400 100 50 65 33 100 65
3 35 18 14 7 35 22
2
SGP4 200 100 100 50 200 100
3 50 25 18 9 65 35
2
SGH6 65 33 25 13 65 25
3 18 9 18
2
SGL6 250-600 100 50 65 33 100 65
3 35 18 14 7 35 22
2
SGP6 200 100 100 50 200 100
3 50 25 18 9 65 35
SK1200 SG
2
SKH8 65 16 50 13 25 13 65 50 25
3
2
SKL8 300-800 100 25 65 16 42 21 14 14 100 65 42 14
3
2
SKP8 140 35 85 25 50 25 18 18 140 85 50 18
3
2
SKH12 65 16 50 13 25 13 65 50 25
3
2
SKL12 600-1250 100 25 65 21 42 16 14 14 100 65 42 14
3
2
SKP12 140 35 70 25 50 25 18 18 140 85 50 18
3
1 microEntelliGuard, MicroVersaTrip Plus, and MicroVersaTrip PM Trip Units only.
SK
The interruption ratings and voltages shown in the table are maximum ratings. A circuit breaker
of the type given in the left-hand column may be applied at the given circuit voltage in any
electrical distribution system where the available fault current at the load terminals of the
breaker does not exceed the value in the table. That circuit breaker type may also be applied at
intermediate values of circuit voltage provided the available fault current at the load terminals of
the breaker does not exceed the value in the table for the higher value of voltage.
FG 600
Ratings
FC 100 Amp Frame; Current Limiting (UL/cUL File No. E-11592)
Maximum UL Listed Interrupting Ratings - IEC Listed Interrupting Ratings, Approx.
Circuit Voltage rms Symmetrical Amperes (in Thousands) Icu, Amperes (in Thousands) Ship
Breaker Ampere No. Rating Vac Vdc Vac Vdc Dimensions in. (mm.) Wt./Std.
Type Rating Poles AC DC 240 480 600/347 250 (2p) 500 (3p) 220-240 400-415 500 250 (2p) 500 (3p) H W D Pack
FCS 15-100 2, 3 600 500 42 25 18 22 30 36 22 14 22 30 6.4 (162.6) 3.0 (76.2) 3.2 (81.3) 2.5 lb/1
FCV 15-100 2, 3 600 500 65 35 22 25 35 50 30 18 25 35 6.4 (162.6) 3.0 (76.2) 3.2 (81.3) 2.5 lb/1
FCN 15-100 2, 3 600 500 150 65 25 30 42 85 50 22 30 42 6.4 (162.6) 3.0 (76.2) 3.2 (81.3) 2.5 lb/1
FCH 15-100 2, 3 600 500 200 100 35 42 65 100 80 36 42 65 6.4 (162.6) 3.0 (76.2) 3.2 (81.3) 2.5 lb/1
FCL 15-100 2, 3 600 500 200 150 42 65 80 200 150 50 65 80 6.4 (162.6) 3.0 (76.2) 3.2 (81.3) 2.5 lb/1
FB 100 Amp Frame; Current Limiting (UL/cUL File No. E-11592)
Maximum UL Listed Interrupting Ratings - Approx.
Circuit Voltage rms Symmetrical Amperes (in Thousands) Ship
Breaker Ampere No. Rating Vac Dimensions in. (mm.) Wt./Std.
Type Rating Poles AC DC 240 277 347 480 600/347 H W D Pack
1 600/347 35 35 22 6.45 (163.8) 1.36 (34.5) 3.28 (83.3) 1.1 lb/1
FBV 15-100 2 600/347 65 35 22 6.45 (163.8) 2.74 (69.6) 3.28 (83.3) 2.6 lb/1
3 600/347 65 35 22 6.45 (163.8) 4.11 (104.4) 3.28 (83.3) 3.3 lb/1
1 600/347 65 65 25 6.45 (163.8) 1.36 (34.5) 3.28 (83.3) 1.1 lb/1
FBN 15-100 2 600/347 150 65 25 6.45 (163.8) 2.74 (69.6) 3.28 (83.3) 2.6 lb/1
3 600/347 150 65 25 6.45 (163.8) 4.11 (104.4) 3.28 (83.3) 3.3 lb/1
1 600/347 100 100 35 6.45 (163.8) 1.36 (34.5) 3.28 (83.3) 1.1 lb/1
FBH 15-100 2 600/347 200 100 35 6.45 (163.8) 2.74 (69.6) 3.28 (83.3) 2.6 lb/1
3 600/347 200 100 35 6.45 (163.8) 4.11 (104.4) 3.28 (83.3) 3.3 lb/1
1 600/347 100 100 42 6.45 (163.8) 1.36 (34.5) 3.28 (83.3) 1.1 lb/1
FBL 15-100 2 600/347 200 150 42 6.45 (163.8) 2.74 (69.6) 3.28 (83.3) 2.6 lb/1
3 600/347 200 150 42 6.45 (163.8) 4.11 (104.4) 3.28 (83.3) 3.3 lb/1
FE 250 Amp Frame; Current Limiting (UL/cUL File No. E-11592)
Maximum UL Listed Interrupting Ratings - Approx.
Circuit Voltage rms Symmetrical Amperes (in Thousands) Ship
Breaker Ampere No. Rating Vac Dimensions in. (mm.) Wt./Std.
Type Rating Poles AC DC 240 480 600 H W D Pack
FEN 250 2 480 - 150 65 - 6.70 (170.1) 4.11 (104.4) 3.52 (89.5) 4.5 lb/1
FEN 250 3 480 - 150 65 - 6.70 (170.1) 4.11 (104.4) 3.52 (89.5) 4.5 lb/1
FEH 250 2 480 - 200 100 - 6.70 (170.1) 4.11 (104.4) 3.52 (89.5) 4.5 lb/1
FEH 250 3 480 - 200 100 - 6.70 (170.1) 4.11 (104.4) 3.52 (89.5) 4.5 lb/1
FG 600 Amp Frame; Current Limiting (UL/cUL File No. E-11592)
Maximum UL Listed Interrupting Ratings - EN 60947-2 Interrupting Ratings, Approx.
Circuit Voltage rms Symmetrical Amperes (in Thousands) Icu, Amperes (in Thousands) Ship
Breaker Ampere No. Rating Vac Vac Dimensions in. (mm.) Wt./Std.
Type Rating Poles AC DC 240 480 600 240 400-415 690 H W D Pack
2 600 150 65 25 10.31 (262.0) 5.46 (138.7) 4.53 (115.0) 22 lb/1
FGN 250-600
3 600 150 65 25 85 50 10 10.31 (262.0) 5.46 (138.7) 4.53 (115.0) 22 lb/1
2 600 200 100 35 10.31 (262.0) 5.46 (138.7) 4.53 (115.0) 22 lb/1
FGH 250-600
3 600 200 100 35 100 80 22 10.31 (262.0) 5.46 (138.7) 4.53 (115.0) 22 lb/1
2 600 200 150 42 10.31 (262.0) 5.46 (138.7) 4.53 (115.0) 22 lb/1
FGL 250-600
3 600 200 150 42 200 150 40 10.31 (262.0) 5.46 (138.7) 4.53 (115.0) 22 lb/1
2 600 200 200 65 10.31 (262.0) 5.46 (138.7) 4.53 (115.0) 22 lb/1
FGP 250-600
3 600 200 200 65 10.31 (262.0) 5.46 (138.7) 4.53 (115.0) 22 lb/1
TED2,3 15 3 600 500 18 18 14 10 101 6 5/16 4 1/8 3 3/8 2 41/64 2 15/64 11/16 23/32 28 lb/8
THED2,3 15 3 600 500 65 25 18 10 101 6 5/16 4 1/8 3 3/8 2 41/64 2 15/64 11/16 23/32 28 lb/8
F225 (UL File E-11592; TFJ, Fixed Thermal Magnetic Trip Unit; TFK, THFK: Interchangeable Thermal Mag. Trip Unit; CSA LR 40350)
TFL8 70-225 3 600 100 100 65 25 10 1/8 4 1/8 3 13/16 3 7/8 3 7/8 11/16 1 3/16
J600 (UL File E-11592; TJJ, Fixed Thermal Magnetic Trip Unit; TJK, THJK: Interchangeable Thermal Mag. Trip Unit; CSA LR 40350)
2 250 20 18 lb/1
TJK6 125-175 600 42 30 22 10 1/8 8 1/4 3 13/16 3 15/16 3 13/16 1 3/8 1 3/16
3 500 20 201 20 lb/1
2 250 40 16 lb/1
THJK4 125-175 600 65 35 25 10 1/8 8 1/4 3 13/16 3 15/16 3 13/16 1 3/8 1 3/16
3 500 40 201 17 1/2 lb/1
2 250 40 18 lb/1
THJK6 125-175 600 65 35 25 10 1/8 8 1/4 3 13/16 3 15/16 3 13/16 1 3/8 1 3/16
3 500 40 201 20 lb/1
THJK4 D 125-400 3 600 40 50 25 10 1/8 8 1/4 3 13/16 3 15/16 3 13/16 1 3/8 1 3/16 17 1/2 lb/1
THJK6 D 250-400 3 600 40 50 25 10 1/8 8 1/4 3 13/16 3 15/16 3 13/16 1 3/8 1 3/16 20 lb/1
K1200 (UL File E-11592; Interchangeable Thermal Magnetic Trip Unit; CSA LR 40350)
2 250 20 33 lb/1
TKM8 300-800 600 42 30 22 15 1/2 8 1/4 5 1/2 8 9/16 5 11/16 1 3/8 5/8
3 500 20 221 39 lb/1
2 38 lb/1
TKM12 600-1200 600 42 30 22 15 1/2 8 1/4 5 1/2 8 9/16 5 11/16 1 3/8 5/8
3 41 1/2 lb/1
2 250 40 33 lb/1
THKM8 300-800 600 65 35 25 15 1/2 8 1/4 5 1/2 8 9/16 5 11/16 1 3/8 5/8
1
3 500 40 22 39 lb/1
2 38 lb/1
THKM12 600-1200 600 65 35 25 15 1/2 8 1/4 5 1/2 8 9/16 5 11/16 1 3/8 5/8
3 41 1/2 lb/1
1UL listed with poles in series for 500 Vdc ungrounded battery applications. 6480Y/277 Vac.
2UL listed as HACR (heating, air conditioning, and refrigeration). 7UL listed 10kA, GE tested to 20kA.
315-50A UL listed as HID (high intensity discharge). 8Not CSA listed
410 amp not UL listed, rated 5kA @ 120V, 240V and 480V
5UL listed/CSA Certified for 10kA @ 347 Vac (TED) and 18kA @ 347V (THED).
Also rated 10kA @ 480V but not UL listed.
Legend
XXX = Variable in Product Number changes per application
TJL6S
Tri-Break (UL File E-42263; Integrally Fused, Thermal Magnetic Trip Unit)
UL Listed Interrupting Ratings
Maximum rms Symmetrical Amps (In Thousands) Approx.
Voltage
Circuit Ship
Rating Vac Vdc Dimensions (In.)
Breaker Ampere No. Wt./Std.
Type Rating Poles ac dc 120 120/240 240 277 480 600 125 250 H W D A B C E Pack
TB11,2 15-100 3 600 200 200 200 10 5/16 4 1/8 3 5/8 2 21/32 6 9/32 11/16 23/32 8 lb/1
31 lb/1
TB41,3 125-400 3 600 200 200 200 16 1/8 8 1/4 4 1/2 3 15/16 9 13/16 1 3/8 1 3/16
33 lb/1
53 lb/1
TB61,3 300-600 3 600 200 200 200 21 7/8 8 1/4 5 7/8 8 9/16 12 1/16 1 3/8 5/8
55 lb/1
53 lb/1
TB81,3 600-800 3 600 200 200 100 21 7/8 8 1/4 5 7/8 8 9/16 12 1/16 1 3/8 5/8
55 lb/1
Mag-Break (UL Files E-11592, E-66390; Magnetic Trip Unit)4
2 480 250 10
TEC 3-150 10 10 10 6 5/16 4 1/8 3 3/8 2 41/64 2 15/64 11/16 23/32 21 lb/6
3 600
TEML 3-150 3 600 250 100 65 25 6 5/16 4 1/8 3 7/8 2 41/64 2 15/64 11/16 23/32 3 1/2 lb/1
TEC & 1.2 lb/1
3-150 3 600 100 100 100 8 3/16 4 1/8 3 3/8 2 41/64 2 15/64 11/16 23/32 TECL Only
TECL5
10 lb/1
TFC 225 3 600 25 22 18 10 1/8 4 1/8 3 13/16 3 7/8 3 7/8 11/16 1 3/16
12 lb/1
31 lb/1
TBC4 225-400 3 600 100 100 100 16 1/8 8 1/4 4 1/2 3 15/16 9 13/16 1 3/8 1 3/16
33 lb/1
53 lb/1
TBC6 600 3 600 100 100 100 21 7/8 8 1/4 5 7/8 8 9/16 12 1/16 1 3/8 5/8
55 lb/1
38 lb/1
TKC 800-1200 3 600 42 30 22 15 1/2 8 1/4 5 1/2 8 9/16 5 11/16 1 3/8 5/8
41 1/2/1
53 lb/1
TBC8 800 3 600 100 100 100 21 7/8 8 1/4 5 7/8 8 9/16 12 1/16 1 3/8 5/8
55 lb/1
MicroVersaTrip (UL File E-11592; Solid-State Trip Units)
TJ4V6,7 42 42 30 22
THJ4V6,7 150-600 3 600 65 65 35 25 10 1/8 8 1/4 3 13/16 3 15/16 3 13/16 1 3/8 1 3/16
TJL4V6 100 100 65 30
TK4V6 800-1200 3 600 42 42 30 22 15 1/2 8 1/4 5 1/2 8 9/16 5 11/16 1 3/8 5/8
TKL4V6 800-1200 3 600 100 100 65 42 15 1/2 8 1/4 5 1/2 8 9/16 5 11/16 1 3/8 5/8
TJH1S-6S 60-600 3 600 65 65 35 25 16 1/8 8 1/4 3 13/16 3 15/16 9 13/16 1 3/8 1 3/16
TJL1S-6S 60-600 3 600 100 100 65 30 16 1/8 8 1/4 3 13/16 3 15/16 9 13/16 1 3/8 1 3/16
TKH8S, 12S 300-1200 3 600 65 65 50 25 21 7/8 8 1/4 5 1/2 8 9/16 12 11/16 1 3/8 5/8
TKL8S, 12S 300-1200 3 600 100 100 65 42 21 7/8 8 1/4 5 1/2 8 9/16 12 11/16 1 3/8 5/8
1 UL listed with internally mounted accessories at 100,000 amps IC. 5 Ratings shown for TEC in combination with TECL.
Contact GE Sales Office for availability of 200 kAIC ratings with 6 With Power+ 4 trip unit.
internal accessories. 7 Suitable for single-phase, use outer two poles.
2 CSA LR 57114.
3 CSA LR 40350.
4 Per UL 489, interrupting capacities are not shown on product label.
THQL 120/240 Vac, Internal Common Trip with Factory Installed Shunt
# of Ampere 240 Vac
Poles Rating Wire Range1 Interrupting Rating Product Number
2 15 14-8 Cu/12-8 Al 10kA THQL2115ST1
2 20 14-8 Cu/12-8 Al 10kA THQL2120ST1
2 30 14-8 Cu/12-8 Al 10kA THQL2130ST1
2 35 8-3 Cu/8-3 Al 10kA THQL2135ST1
2 40 8-3 Cu/8-3 Al 10kA THQL2140ST1
2 45 8-3 Cu/8-3 Al 10kA THQL2145ST1
2 50 8-3 Cu/8-3 Al 10kA THQL2150ST1
2 60 8-3 Cu/8-3 Al 10kA THQL2160ST1
2 70 6-1/0 Cu/4-1/0 Al 10kA THQL2170ST1
2 80 6-1/0 Cu/4-1/0 Al 10kA THQL2180ST1
2 90 6-1/0 Cu/4-1/0 Al 10kA THQL2190ST1
2 100 6-1/0 Cu/4-1/0 Al 10kA THQL21100ST1
3 20 14-8 Cu/12-8 Al 10kA THQL32020ST1
3 30 14-8 Cu/12-8 Al 10kA THQL32030ST1 THQL32020ST1
3 40 8-3 Cu/8-3 Al 10kA THQL32040ST1
3 50 8-3 Cu/8-3 Al 10kA THQL32050ST1
3 60 8-3 Cu/8-3 Al 10kA THQL32060ST1
3 70 6-1/0 Cu/4-1/0 Al 10kA THQL32070ST1
3 80 6-1/0 Cu/4-1/0 Al 10kA THQL32080ST1
3 90 6-1/0 Cu/4-1/0 Al 10kA THQL32090ST1
3 100 6-1/0 Cu/4-1/0 Al 10kA THQL32100ST1
Dual Function GFCI/AFCI Ground Fault & Combination Arc Fault Circuit Breaker
(Available December 2014)
# of Ampere 120 Vac
Poles Rating Wire Range1 Interrupting Rating Product Number
1 15 14-8 Cu/12-8 Al 10kA THQL1115DF
1 20 14-8 Cu/12-8 Al 10kA THQL1120DF THQL1115AF2
1 15 14-8 Cu/12-8 Al 22kA THHQL1115DF
1 20 14-8 Cu/12-8 Al 22kA THHQL1120DF
1Solid or stranded for 14-10 AWG.
2Combination AFCI compliant with NEC 2008 and later.
THQL and THHQL 120 Vac, Equipment Protection Ground Fault Circuit
Breakers Internal Common Trip
# of Ampere 120 Vac
Poles Rating Wire Range1 Interrupting Rating Product Number
1 15 14-8 Cu/12-8 Al 10kA THQL1115GFEP
1 20 14-8 Cu/12-8 Al 10kA THQL1120GFEP
1 30 14-8 Cu/12-8 Al 10kA THQL1130GFEP
THQL and THHQL 120/240 Vac or 208Y/120 Vac, Equipment Protection THQL2120HID
Ground Fault Circuit Breakers
# of Ampere 120/240 Vac or 208Y/120
Poles Rating Wire Range1 Interrupting Rating Product Number
2 15 14-8 Cu/12-8 Al 10kA THQL2115GFEP
2 20 14-8 Cu/12-8 Al 10kA THQL2120GFEP
2 30 14-8 Cu/12-8 Al 10kA THQL2130GFEP
THQL and THHQL 120/240 Vac, High Intensity Discharge Lighting Loads
# of Ampere 120/240 Vac
Poles Rating Wire Range1 Interrupting Rating Product Number
1 15 14-8 Cu/12-8 Al 10kA THQL1115HID2
1 20 14-8 Cu/12-8 Al 10kA THQL1120HID2
1 25 14-8 Cu/12-8 Al 10kA THQL1125HID
1 30 14-8 Cu/12-8 Al 10kA THQL1130HID
1 15 14-8 Cu/12-8 Al 22kA THHQL1115HID2
1 20 14-8 Cu/12-8 Al 22kA THHQL1120HID2
1 25 14-8 Cu/12-8 Al 22kA THHQL1125HID
1 30 14-8 Cu/12-8 Al 22kA THHQL1130HID
UL listed as HID.
THQL and THHQL 120/240 Vac, Internal Common Trip For High Intensity
Discharge Lighting Loads
# of Ampere 120/240 Vac
Poles Rating Wire Range1 Interrupting Rating Product Number
2 15 14-8 Cu/12-8 Al 10kA THQL2115HID
2 20 14-8 Cu/12-8 Al 10kA THQL2120HID
2 25 14-8 Cu/12-8 Al 10kA THQL2125HID
2 30 14-8 Cu/12-8 Al 10kA THQL2130HID
2 15 14-8 Cu/12-8 Al 22kA THHQL2115HID
2 20 14-8 Cu/12-8 Al 22kA THHQL2120HID
2 25 14-8 Cu/12-8 Al 22kA THHQL2125HID
2 30 14-8 Cu/12-8 Al 22kA THHQL2130HID
UL listed as HID.
1Solid or stranded for 14-10 AWG.
2UL listed as SWD (switching duty). Suitable for 120 Vac fluorescent lighting loads.
THQL1120HM
THQL 120 Vac, For Factory Installed Shunt Trip2,3 Internal Common Trip
# of Ampere 120 Vac
Poles Rating Wire Range1 Interrupting Rating Product Number
3 20 14-8 Cu/12-8 Al 10kA THQL32020ST1
THQB, THHQB 120/240 Vac, Ground Fault Circuit Interrupters, Self Testing, cULus
# of Ampere 120/240 Vac
Poles Rating Wire Range1 Interrupting Rating Product Number THQB1115GF
1 15 14-8Cu/12-8 Al 10kA THQB1115GFT
1 20 14-8Cu/12-8 Al 10kA THQB1120GFT
1 25 14-8 Cu/12-8 Al 10kA THQB1125GFT
1 30 14-8Cu/12-8 Al 10kA THQB1130GFT
1 15 14-8Cu/12-8 Al 22kA THHQB1115GFT
1 20 14-8Cu/12-8 Al 22kA THHQB1120GFT
1 25 14-8 Cu/12-8 Al 22kA THHQB1125GFT
1 30 14-8Cu/12-8 Al 22kA THHQB1130GFT
2 15 14-8Cu/12-8 Al 10kA THQB2115GFT
2 20 14-8Cu/12-8 Al 10kA THQB2120GFT
2 25 14-8 Cu/12-8 Al 10kA THQB2125GFT
2 30 14-8Cu/12-8 Al 10kA THQB2130GFT
THQB 120 Vac, Ground Fault Circuit Interrupters (30 ma); cULus
# of Ampere 120 Vac
Poles Rating Wire Range1 Interrupting Rating Product Number
1 15 14-8 Cu/12-8 Al 10kA THQB1115GFEP
1 20 14-8 Cu/12-8 Al 10kA THQB1120GFEP
1 30 14-8 Cu/12-8 Al 10kA THQB1130GFEP
THQB 120/240 or 208Y/120 Vac, Ground Fault Circuit Interrupters (30 ma); cULus
Internal Common Trip
# of Ampere 120/240 or 208Y/120 Vac
Poles Rating Wire Range1 Interrupting Rating Product Number
2 15 14-8 Cu/12-8 Al 10kA THQB2115GFEP
2 20 14-8 Cu/12-8 Al 10kA THQB2120GFEP
2 30 14-8 Cu/12-8 Al 10kA THQB2130GFEP
2 40 14-8 Cu/12-8 Al 10kA THQB2140GFEP
1Solid or stranded for 14-10 AWG.
2Combination AFCI compliant with NEC 2008 and later.
THHQB 120/240 Vac, Internal Common Trip, High Intensity Discharge Lighting Loads1
# of Ampere 120/240 Vac
Poles Rating Wire Range2 Interrupting Rating Product Number
2 15 14-8 Cu/12-8 Al 22kA THHQB2115HID
2 20 14-8 Cu/12-8 Al 22kA THHQB2120HID
2 25 14-8 Cu/12-8 Al 22kA THHQB2125HID
2 30 14-8 Cu/12-8 Al 22kA THHQB2130HID
THQB 120 Vac with Factory Installed 120 Vac Shunt Trip4,5
# of Ampere 120 Vac
Poles Rating Wire Range2 Interrupting Rating Product Number
1 20 14-8 Cu/12-8 Al 10kA THQB1120ST1
THQB 120 Vac, Internal Common Trip with Factory Installed 120 Vac Shunt Trip4,5
# of Ampere 120 Vac
Poles Rating Wire Range2 Interrupting Rating Product Number
2 20 14-8 Cu/12-8 Al 10kA THQB2120ST1
2 30 14-8 Cu/12-8 Al 10kA THQB2130ST1
2 100 6-1/0 Cu/4-1/0 Al 10kA THQB21100ST1
3 20 14-8 Cu/12-8 Al 10kA THQB32020ST1
3 30 14-8 Cu/12-8 Al 10kA THQB32030ST1
3 35 8-3 Cu/8-3 Al 10kA THQB32035ST1
3 40 8-3 Cu/8-3 Al 10kA THQB32040ST1
3 50 8-3 Cu/8-3 Al 10kA THQB32050ST1
3 60 8-3 Cu/8-3 Al 10kA THQB32060ST1
3 70 6-1/0 Cu/4-1/0 Al 10kA THQB32070ST1
3 80 6-1/0 Cu/4-1/0 Al 10kA THQB32080ST1
3 90 6-1/0 Cu/4-1/0 Al 10kA THQB32090ST1
3 100 6-1/0 Cu/4-1/0 Al 10kA THQB32100ST1
THQB 120 Vac with Switching Neutral Single Thermal Magnetic Pole;
Single Nonautomatic Pole
# of Ampere 120 Vac
Poles Rating Wire Range2 Interrupting Rating Product Number
2 15 14-8 Cu/12-8 Al 10kA THQB21WY15
2 20 14-8 Cu/12-8 Al 10kA THQB21WY20
2 25 14-8 Cu/12-8 Al 10kA THQB21WY25
2 30 14-8 Cu/12-8 Al 10kA THQB21WY30
THQB 120 Vac with Switching Neutral Two Thermal Magnetic Pole;
Single Nonautomatic Pole
# of Ampere 120 Vac
Poles Rating Wire Range2 Interrupting Rating Product Number
3 15 14-8 Cu/12-8 Al 10kA THQB31WY15
3 20 14-8 Cu/12-8 Al 10kA THQB31WY20
3 25 14-8 Cu/12-8 Al 10kA THQB31WY25
3 30 14-8 Cu/12-8 Al 10kA THQB31WY30
1UL listed as HID (high intensity discharge).
2Solid or stranded for 14-10 AWG.
3UL listed as SWD (switching duty). Suitable for switching 120 Vac fluorescent lighting loads.
4For additional shunt trip offerings see page 6-41.
520-60 ampere are UL listed as HACR (heating, air conditioning and refrigeration).
UL listed HACR (heating, air conditioning and refrigeration). Refer to Q-Line accessories listed on pages 6-30 to 6-31.
Product Features
Multi-terminal Configuration Breakers
35 mm DIN rail mounting
Optional front/rear panel mounting kitsTHQCFMK, page 6-30.
Optional load end terminal for up to (4) 0.25-inch quick connnects.
Contact local GE sales office for ring terminal configurationsnot DIN rail compatible.
TQD 240 Vac, Internal Common Trip with Factory Installed 120 Vac Shunt Trip3
# of Ampere 240 Vac
Poles Rating Interrupting Rating Product Number 1,2
3 125 10kA TQD32125ST1
3 150 10kA TQD32150ST1
3 175 10kA TQD32175ST1
3 200 10kA TQD32200ST1
3 225 10kA TQD32225ST1
Cable In-Cable Out (Lug-Lug) TQC 120/240 Vac, Internal Common Trip
# of Ampere 120/240 Vac
Poles Rating Wire Range1 Short Circuit Withstand Rating Product Number
2 60 8-3 Cu/8-3 Al 10kA TQC21Y60
2 100 6-1/0 Cu/4-1/0 Al 10kA TQC21Y100
Cable In-Cable Out (Lug-Lug) TQC 240 Vac, Internal Common Trip
# of Ampere 240 Vac
Poles Rating Wire Range1 Short Circuit Withstand Rating Product Number
2 60 8-3 Cu/8-3 Al 10kA TQC22Y60
2 100 6-1/0 Cu/4-1/0 Al 10kA TQC22Y100
3 60 8-3 Cu/8-3 Al 10kA TQB32Y60
3 100 6-1/0 Cu/4-1/0 Al 10kA TQB32Y100
Cable In-Cable Out (Lug-Lug) TQD, TJD 240 Vac, Internal Common Trip
# of Ampere 240 Vac
Poles Rating Short Circuit Withstand Rating Product Number 4
2 225 14kA TQD22Y225
3 225 14kA TQD32Y2252
2 400 22kA TJD422Y400
3 400 22kA TJD432Y4003
1Solid or stranded for 14-10 AWG.
2TQD32YT225 with dummy trip used for accessorized applications.
3TJD uses same accessories as J600 line.
4Refer to table on page 6-106 for lug and wire range data. Line and load lugs included in basic switch product number.
TQHT1
TEY and TEYF breakers are one-inch wide per pole, compact, bolt-on circuit breakers
for use on grounded 480Y/277 Vac systems. Short circuit ratings at that voltage for TEY
and TEYF are 14 and 18kA, respectively. TEYF also offers higher selectivity ratings with
upstream devices (See DET-537 for details). The bolt-on mounting base (TEY3B) shown
on page 6-102 makes TEY and TEYF suitable for various lug-lug applications.
TEY/TEYF (UL File E-11592; CSA LR 57114)
Ampere
Rating Wire Range1 Product Number Product Number
Type TEY3,4 Type TEYF3,4
Single Pole - Includes Integral Cu/Al Load Lugs 14kA @ 277 Vac 18kA @ 277 Vac
15 #14-#10 TEY1152 TEYF1152
20 #14-#10 TEY1202 TEYF1202
25 #14-#10 TEY125 TEYF125
30 #14-#10 TEY130 TEYF130
35 #10-#4 TEY135 TEYF135
40 #10-#4 TEY140 TEYF140 1- 2- and 3-pole TEY/TEYF breakers
45 #10-#4 TEY145 TEYF145
50 #10-#4 TEY150 TEYF150
60 #10-#4 TEY160 TEYF160
70 #4-1/0 TEY170
80 #4-1/0 TEY180
90 #4-1/0 TEY190
100 #4-1/0 TEY1100
Type TEY3,4 Type TEYF3,4
Two-Pole - Includes Integral Cu/Al Load Lugs 14kA @ 480 / 277 Vac 18kA @ 480 / 277 Vac
15 #14-#10 TEY215 TEYF215
20 #14-#10 TEY220 TEYF220
25 #14-#10 TEY225 TEYF225
30 #14-#10 TEY230 TEYF230
35 #10-#4 TEY235 TEYF235
40 #10-#4 TEY240 TEYF240
45 #10-#4 TEY245 TEYF245
50 #10-#4 TEY250 TEYF250
60 #10-#4 TEY260 TEYF260
70 #4-1/0 TEY270 TEYF270
80 #4-1/0 TEY280 TEYF280
90 #4-1/0 TEY290 TEYF290
100 #4-1/0 TEY2100 TEYF2100
110 #4-2/0 TEYF2110B
125 #4-2/0 TEYF2125B
Type TEY3,4 Type TEYF3,4
Three-Pole - Includes Integral Cu/Al Load Lugs 14kA @ 480 / 277 Vac 18kA @ 480 / 277 Vac
15 #14-#10 TEY315 TEYF315
20 #14-#10 TEY320 TEYF320
25 #14-#10 TEY325 TEYF325
30 #14-#10 TEY330 TEYF330
35 #10-#4 TEY335 TEYF335
40 #10-#4 TEY340 TEYF340
45 #10-#4 TEY345 TEYF345
50 #10-#4 TEY350 TEYF350
60 #10-#4 TEY360 TEYF360
70 #4-1/0 TEY370 TEYF370
80 #4-1/0 TEY380 TEYF380
90 #4-1/0 TEY390 TEYF390
100 #4-1/0 TEY3100 TEYF3100
110 #4-2/0 TEYF3110B
125 #4-2/0 TEYF3125B
1Solid or stranded for 14-10 AWG.
2Single-pole, 15 and 20 ampere breakers are also UL listed as switching duty breakers, suitable for switching
120, 240, or 277 Vac.
3UL listed HACR (Heating, Air Conditioning, Refrigeration).
4UL listed for HID (high intensity discharge), all 50A or less.
Internal Accessories for TEY/TEYF (2- and 3-pole breaker only) Factory Installed Only
Auxiliary Switch, Single-Pole Add suffix to Breaker
(5A at 120, 240, 277 Vac, 1/4 hp at 120, 240 Vdc) Product Number
A switch (normally open) AS1A5
B switch (normally closed) AS1B5
AB switch (both) ASAB5
Shunt Trip 120-277 Vac control voltage ST125
5Limited to one accessory per breaker.
The TEY family of circuit breakers (TEY, TEYF, TEYD, TEYH, and TEYL) are one-inch wide per
pole, compact, bolt-on circuit breakers for use on grounded 480Y/277 Vac systems, and
are typically installed within Lighting Panelboards, including GE A-Series. Short circuit
ratings at 480/277 Vac are shown in the tables that follow. Ratings at other voltages are
shown in the Quick Reference Guide at the beginning of this section. Bolt-On mounting
bases TEY3B (page 6-102) and TEY3B125 (page 6-34) make these frames suitable for
unit mount / lug-lug connected applications. Handle tie kits, suitable for use with multiple
single pole breakers used on shared neutral circuits (page 6-34) are available for
TEYD/H/L circuit breakers.
TEB 1 1 1 015 WL
Single Pole Includes Cu/Al load lugs only. If line lugs are required, add suffix WL to Product Number.
Type TEB Type TED Type THED
120 Vac 125 Vdc 277 Vac 125 Vdc 347 Vac1 277 Vac 347 Vac1
Ampere
Rating Product Number Product Number Product Number Product Number Product Number
10 TEB1110102,4 TED1130102,4
15 TEB1110153,4 TED1130153,4 TED1140153,4 THED1130154 THED1140153,4
20 TEB1110203,4 TED1130203,4 TED1140203,4 THED1130204 THED1140203,4
25 TEB1110254 TED1130254 TED1140254 THED1130254 THED1140254
30 TEB1110304 TED1130304 TED1140304 THED1130304 THED1140304
35 TEB1110354 TED1130354
40 TEB1110404 TED1130404
45 TEB1110454 TED1130454
50 TEB1110504 TED1130504
60 TEB111060 TED113060
70 TEB111070 TED113070
80 TEB111080 TED113080
90 TEB111090 TED113090
100 TEB111100 TED113100
Two Pole Includes Cu/Al line and load lugs. For optional lugs, see page 6-103 and 6-105.
Type TEB Type TED Type THED, Hi-Break 5
240 Vac, 250 Vdc 480 Vac, 250 Vdc 480 Vac, 250 Vdc
Ampere
Rating Product Number Product Number Product Number
10 TEB122010WL2,4 TED124010WL2,4
15 TEB122015WL4 TED124015WL4 THED124015WL4
20 TEB122020WL4 TED124020WL4 THED124020WL4
25 TEB122025WL4 TED124025WL4 THED124025WL4
30 TEB122030WL4 TED124030WL4 THED124030WL4
35 TEB122035WL4 TED124035WL4 THED124035WL4
40 TEB122040WL4 TED124040WL4 THED124040WL4
45 TEB122045WL4 TED124045WL4 THED124045WL4
50 TEB122050WL4 TED124050WL4 THED124050WL4
60 TEB122060WL TED124060WL THED124060WL
70 TEB122070WL TED124070WL THED124070WL
80 TEB122080WL TED124080WL THED124080WL
90 TEB122090WL TED124090WL THED124090WL
100 TEB122100WL TED124100WL THED124100WL
110 TED124110WL
125 TED124125WL
150 TED124150WL
1Suitable for 10 kAIC at 480 Vac, but not labeled or UL listed.
2Not UL listed, rated 5kA @ 120V, 240V and 480V.
3Single-pole, 15-and 20-ampere breakers are also UL listed as switching duty breakers, suitable for switching 120 Vac (TEB), 277, 347 Vac (TED, THED) fluorescent lighting loads.
4UL listed for HID (high intensity discharge).
5Two-pole breaker is furnished in three-pole case.
Notes: All TEB, TED, THED breakers UL listed as HACR type except 10 ampere.
All TEB, TED, THED breakers suitable for reverse feed.
60/75C rating through 100 amperes, 75C rating above 100 amperes.
Three Pole Includes Cu/Al line and load lugs. For optional lugs, see page 6-103 and 6-105.
Type TEB Type TED Type THED, Hi-Break
240 Vac 480 Vac 600 Vac 600 Vac
Ampere
Rating Product Number Product Number Product Number Product Number
10 TEB132010WL1,3 TED134010WL1,3
15 TEB132015WL3 TED134015WL3
20 TEB132020WL3 TED134020WL3 TED136020WL3 THED136020WL3
25 TEB132025WL3 TED134025WL3 TED136025WL3 THED136025WL3
30 TEB132030WL3 TED134030WL3 TED136030WL3 THED136030WL3
35 TEB132035WL3 TED134035WL3 TED136035WL3 THED136035WL3
40 TEB132040WL3 TED134040WL3 TED136040WL3 THED136040WL3
45 TEB132045WL3 TED134045WL3 TED136045WL3 THED136045WL3
50 TEB132050WL3 TED134050WL3 TED136050WL3 THED136050WL3
60 TEB132060WL TED134060WL TED136060WL
70 TEB132070WL TED134070WL TED136070WL THED136070WL
80 TEB132080WL TED134080WL TED136080WL
90 TEB132090WL TED134090WL TED136090WL THED136090WL
100 TEB132100WL TED134100WL TED136100WL THED136100WL
110 TED134110WL TED136110WL THED136110WL
125 TED134125WL TED136125WL THED136125WL
150 TED134150WL TED136150WL THED136150WL
100NA TED134YT1002 TED136YT1002
150NA TED134YT1502 TED136YT1502
1Not UL listed, rated 5kA @ 120V, 240V and 480V.
2Includes factory-installed dummy trip.
3UL listed for HID (high intensity discharge).
Notes: All TEB, TED, THED breakers UL listed as HACR type except 10 ampere.
All TEB, TED, THED breakers suitable for reverse feed.
60/75C rating through 100 amperes, 75C rating above 100 amperes.
Type TJJ Noninterchangeable Trip, includes Cu/Al Line and Load Lugs, suitable for reverse feed
Frame
2-Pole, 400 Ampere Frame 3-Pole, 400 Ampere Frame Terminal Lugs for Front
Adjustable Instantaneous 600 Vac, 250 Vdc 600 Vac Connection (Cu/Al)
Trip Ampere Range
Ampere Product Product Copper/ Wire
Rating Low High Number Number Aluminum Lugs Size
200 600 2000 TJJ426200WL TJJ436200WL
225 675 2250 TJJ426225WL TJJ436225WL TCAL433
(1) 6-600
250 750 2500 TJJ426250WL TJJ436250WL Included in
or
300 900 3000 TJJ426300WL TJJ436300WL price of
(2) 2/0-250 Cu/Al
350 1050 3500 TJJ426350WL TJJ436350WL breaker
400 1200 4000 TJJ426400WL TJJ436400WL
Types TJK, THJK Interchangeable Trip, includes Cu/Al Line and Load Lugs, not suitable for reverse feed
Complete Circuit Breaker Terminal Lugs for Front
Includes Line and Load Lugs Connection (Cu/Al)1
Adjustable Instantaneous
Trip Ampere Frame Only Trip Unit Only. Use Product Number
Ampere Range Standard Hi-Break Product with Standard and (Order 2
Rating Low High Product Number Product Number Number Hi-Break Frames per pole) Wire Size
400A FrameTwo-Pole
200 600 2000 TJK426200WL THJK426200WL TJK426F000 TJK426T200
225 675 2250 TJK426225WL THJK426225WL Standard Frame TJK426T225
(1) 6-600
250 750 2500 TJK426250WL THJK426250WL TJK426T250
TCAL433 or
300 900 3000 TJK426300WL THJK426300WL THJK426F000 TJK426T300
(2) 2/0-250 Cu/Al
350 1050 3500 TJK426350WL THJK426350WL Hi-Break TJK426T350
400 1200 4000 TJK426400WL THJK426400WL TJK426T400
400A FrameThree-Pole
200 600 2000 TJK436200WL THJK436200WL TJK436F000 TJK436T200
225 675 2250 TJK436225WL THJK436225WL Standard Frame TJK436T225
250 750 2500 TJK436250WL THJK436250WL TJK436T250
300 900 3000 TJK436300WL THJK436300WL TJK436T300 (1) 6-600
350 1050 3500 TJK436350WL THJK436350WL THJK436F000 TJK436T350 TCAL433 or
400 1200 4000 TJK436400WL THJK436400WL Hi-Break TJK436T400 (2) 2/0-250 Cu/Al
400 600 2000 TJK436TM14002
Mag 1200 4000 TJK436TM24002
Only 350 1000 TJK436TM34002
1For optional lugs, see page 6-103.
2Not UL listed.
3Alternate lug for 750 kcmil Cu/Al cable, Product Number TCAL47.
Types TJK, THJK Interchangeable Trip, includes Cu/Al Line and Load Lugs, not suitable for reverse feed
Complete Circuit Breaker Terminal Lugs for Front
Includes Line and Load Lugs Connection (Cu/Al)1
Adjustable Instantaneous
Trip Ampere Frame Only Trip Unit Only. Use Product Number
Ampere Range Standard Hi-Break Product w/ Standard and (Order 2
Rating Low High Product Number Product Number Number Hi-Break Frames per pole) Wire Size
600A FrameTwo-Pole
250 750 2500 TJK626250WL THJK626250WL TJK626F000 TJK626T250 TCAL432 (1)
(1) 6-600
6-600
300 900 3000 TJK626300WL THJK626300WL TJK626F000
Standard TJK626T300 TCAL432 or
or
350 1050 3500 TJK626350WL THJK626350WL Standard
Frame TJK626T350 (2)
(2) 2/0-250 Cu/Al
2/0-250 Cu/Al
400 1200 4000 TJK626400WL THJK626400WL Frame
THJK626F000 TJK626T400
450 1350 4500 TJK626450WL THJK626450WL THJK626F000
Hi-Break TJK626T450 (2) 4/0-350
(2) 4/0-350 Cu
Cu
500 1500 5000 TJK626500WL THJK626500WL Hi-Break TJK626T500 TCAL63
TCAL63 or
Frame or
600 1800 6000 TJK626600WL THJK626600WL TJK626T600 (2) 300-500
(2) 300-500 Al
Al
600A FrameThree-Pole
250 750 2500 TJK636250WL THJK636250WL TJK636T250 (1)
(1) 6-600
6-600
300 900 3000 TJK636300WL THJK636300WL TJK636F000 TJK636T300 or
TJK636F000 TCAL432 or
350 1050 3500 TJK636350WL THJK636350WL Standard TJK636T350 (2) 2/0-250
2/0-250 Cu/Al
Standard (2) Cu/Al
400 1200 4000 TJK636400WL THJK636400WL Frame TJK636T400
450 1350 4500 TJK636450WL THJK636450WL Frame
THJK636F000 TJK636T450
500 1500 5000 TJK636500WL THJK636500WL THJK636F000
Hi-Break TJK636T500 TCAL63 (2) 4/0-350 Cu
Hi-Break (2) 4/0-350
or Cu
600 1800 600 TJK636600WL THJK636600WL Frame TJK636T600 TCAL63
Frame or
(2) 300-500 Al
600 6000 2000 TJK636TM16003
(2) 300-500 Al
Mag
1800 6000 TJK636TM26003
Only
1For optional lugs, see page 6-103.
2Alternate lug for 750 kcmil Cu/Al cable, Product Number TCAL47
3Not UL listed.
Mounting Pole Inst. Mounting Pole Inst. Mounting Pole Inst. Mounting Pole Inst. Total Number of
Sheet Sheet Sheet Sheet Accessories Within any
Breaker Type L C R GEH- L R GEH- L R GEH- L R GEH- One Circuit Breaker
TQB, THQB,
One accessory only. Mounts
THHQB, TXQB,
4 in a one-inch frame and
TQL, THQL, UL
increase overall breaker size
THHQL, TXQL,
by one pole. May be applied
TQC, THQC,
to 1-, 2-, or 3-pole breakers.
THHQC, TXQC
4
TQD, THQD UL One accessory only
E150 TEB,
TEC, TED, 3418 2-pole circuit breakerany
Aux one 3-pole circuit breaker
THED, UL7 UL 4576 UL 7 UL UL 3417 UL 8 3434
THLC1, 3416 any two except UVR and
S.T. 3-coil shunt trip
TB15,6,8
F225 9
TFC, TFJ, TFK,
THFK, THLC2, UL 4620 UL UL 4653 UL UL 4653 UL8 UL 4622 any two
THLC4, TLB2,
TLB4
J600 TJC, 3321
TJD, TJJ, Any two plus bell alarm except
Aux
TJK, THJK,
UL 8 3320 UL UL
3435
UL 5407 UL8 3346 TB4, TBC4 any one plus bell
alarm .
TB45, TBC45 S.T.
K1200 TKC, 3321
TKM, THKM Aux
UL 8 4305 UL UL UL 5408 UL8 3346 Any two plus bell alarm
TB65, TBC65 3344
TB8, TBC8 S.T.
Red Red
White Brown/white
Brown/white
Accessory-Lead Auxiliary Switch Blue All accessory contacts shown
with the circuit breaker in
Color Coding10 White tripped position.
Purple
Black Blue
Yellow Yellow
Brown Black Blue Black
Bell Alarm Switch Shunt Trip Undervoltage Release Three-Coil Shunt Trip
1 Except TFC and TFJ, F225 line model 4 frames and trips (mfg. code date J101+ (1981 or later), and THLC2, THLC4, TLB4 are UL listed for
field installation of most accessories.
2 Not UL listed.
3 600 Vac auxiliary switches are not UL listed.
4 Accessories are factory installed only.
5 UL listed at 200 AIC without internal accessories, 100 AIC with internally mounted accessories.
6 Accessories not available for single-pole TEB/TED frame. Use two-pole circuit breaker.
7 Left pole mounting available for two-pole THED but not for two-pole TEB, TED.
8 Not available with lead exit from the back of breaker.
9 UL listed interrupting capacity with accessories: 10 kAIC at 600 Vac, 22 kAIC at 480 Vac, 22 kAIC at 240 Vac.
10Leads are #18 125C Vulkene insulated.
Auxiliary Switches
Unless otherwise noted switch is SPDT rated 6 amperes at rated ac voltage, 1/2 amperes at 125 Vdc, 1/4 amperes at 250 Vdc.
Control Voltage 240 Vac, 250 Vdc Maximum Control Voltage 600 Vac, 250 Vdc Maximum
UL Listed When Factory Installed Suffix1 Not UL Listed Suffix1
Number of Add to Base Product Add to Base Product
SPDT Switch Base Number for Factory Base Number for Factory
Breaker Type Elements Number Installation4 Number Installation4
TEB, TEC, TB1 1 TEDAS2AB1R,L2,3 S TEDAS6AB1R,L2,3 S
TED, THED,THLC13 2 TEDAS2AB2R,L2,3 S TEDAS6AB2R,L2,3 S
1 TJKASA2AB1R,L S TJKASA6AB1R,L S
2 TJKASA2AB2R,L S TJKASA6AB2R,L S
TJC, TJD, TJJ, TJK, THJK
3 TJKASA2AB3R,L S TJKASA6AB3R,L S
4 TJKASA2AB4R,L S TJKASA6AB4R,L S
1 TB4ASA2AB1R,L S TB4ASA6AB1R,L S
2 TB4ASA2AB2R,L S TB4ASA6AB2R,L S
TB4, TBC4
3 TB4ASA2AB3R,L S TB4ASA6AB3R,L S
4 TB4ASA2AB4R,L S TB4ASA6AB4R,L S
1 TKMAAS2AB1 RS or LS TKMAAS6AB1 RS or LS
TKM, THKM, TKC, TB6, 2 TKMAAS2AB2 RS or LS TKMAAS6AB2 RS or LS
TB8, TBC6, TBC8 3 TKMAAS2AB3 RS or LS TKMAAS6AB3 RS or LS
4 TKMAAS2AB4 RS or LS TKMAAS6AB4 RS or LS
1"S" suffix for wires out the side of breaker. For lead exit from back of breaker, replace suffix "S" with "B" and multiply list price by 1.25. "B" suffix not UL listed. Not available
with leads out the back for "Q-Line", or 2 element auxiliary switches used on TFG, TFJ, TFK, THFK, THLC2, THLC4, TLB2, and TLB4.
2Auxiliary switch mounts in right pole only on two-pole TEB, TED breakers. (Factory installed only.)
3Not available with B suffixleads out back.
4For factory installation, contact Customer Service Center.
How to Order
For field replacement, order base number only. For factory installation, contact Customer
Service Center and order base number plus appropriate suffix. For a nonautomatic breaker
(molded case switch) a dummy trip is required when installing either a shunt trip or UVR.
Shunt Trip
Remote Tripping Trips breaker by remote control. Trip coil de-energized when breaker
opens. Device meets UL requirements for service to ground fault system.
Undervoltage Release
Undervoltage release automatically trips breaker when applied coil voltage drops to
30 to 70 percent of rated value. Time-delay unit prevent nuisance tripping due to
momentary loss of voltage. Separate externally mounted unit has 120 Vac input and
125 Vdc output. Used in conjunction with 125 Vdc undervoltage release which must be
ordered separately. Product number SPUVTD for adjustable delay .1 to 1.0 seconds.
Shunt Trip
Product Number1,2 UL Listed When Factory Installed
Suffix Number3
Accessory Voltage Base Number Add to Base Product Number
Breaker Type Vac Vdc for Field Replacement for Factory Installation
120-240 TQSTA14,5,6,7 10
TQB, THQB, THHQB, TXQB,
12 TQSTA74,6,7 10
TQL, THQL, THHQL, TXQL
24-48 TQSTA84,6,7 10
120 TQDST18,9 10
240 TQDST29 10
TQD, THQD
12 TQDST79 10
24 TQDST89 10
120 TEDST12 RS
240 TEDST12 RS
480 TEDST13 RS
600 TEDST13 RS
TEB, TEC, TB1-B11,
12 TEDST7 RS
TED, THED, THLC1
24 TEDST8 RS
48 TEDST9 RS
125 TEDST12 RS
250 TEDST11 RS
120 TFKSTA121 RS or LS
240 TFKSTA121 RS or LS
480 TFKSTA131 RS or LS
600 TFKSTA131 RS or LS
TFC, TFJ, TFK, THFK, THLC2,
12 TFKSTA71 RS or LS
THLC4, TLB2, TLB4
24 TFKSTA81 RS or LS
48 TFKSTA91 RS or LS
125 TFKSTA121 RS or LS
250 TFKSTA111 RS or LS
1UL listed for field installation on TFC, TFJ, TFK, and THFK model 4 frames and trips (mfg. Code date J101 or later) and on THLC2, THLC4, TLB4.
2For replacement voltage suppressor on 120 Vac UVRs for F225 line, order Product Number 286A8062G1. for 120 Vac UVRs on all other breaker lines, order Product Number
192A8300G1.
3"S" suffix for wires out the side of the breaker. For lead exit from back of breaker, replace suffix "S" with "B", and multiply "S" accessory List Price by 1.25. "B" suffix not UL listed.
Not available with leads out the back on "Q-Line." For factory installation, contact Customer Service Center.
4Mounts on a one-inch frame and increases overall breaker size by one pole added to left side. May be applied to 1-, 2-, or 3-pole breakers. Maximum total breaker width is
4-pole. Must be factory installed.
5A selective listing of breaker product numbers that include 120 Volt ac shunt trip appears on page 6-22.
6Not available on GFCI (5 ma) or Equipment Ground Fault (30 ma) breakers.
7TQST shunt trips not available on breakers over 100 A.
8Not available with B suffixleads out back.
9Must be factory installed, right pole only.
10To order, specify both the accessory and breaker product number =, e.g. THQL2130, TQST1 identifies a 30 A, 2-pole plug-in breaker with a factory installed 120 Vac
shunt trip.
11For TB1 with bolt-on limiters.
Undervoltage Release
Product Number1,2 UL Listed When Factory Installed
Suffix Number3
Accessory Voltage Base Number Add to Base Product Number
Breaker Type Vac Vdc for Field Replacement for Factory Installation
120 TEDUV1 RS
240 TEDUV2 RS
480 TEDUV4 RS
600 TEDUV6 RS
TEB, TEC, TB1-B4
12 TEDUV7 RS
TED, THED, THLC1
24 TEDUV8 RS
48 TEDUV9 RS
125 TEDUV10 RS
250 TEDUV11 RS
120 TJUV1R S
240 TJUV2R S
480 TJUV4R S
600 TJUV6R S
TJC, TJD, TJJ, TJK, THJK 12 TJUV7R S
24 TJUV8R S
48 TJUV9R S
125 TJUV10R S
250 TJUV11R S
120 TKUV1R S
240 TKUV2R S
480 TKUV4R S
600 TKUV6R S
TKC, TKM, THKM, TB6,
12 TKUV7R S
TB8, TBC6, TBC85
24 TKUV8R S
48 TKUV9R S
125 TKUV10R S
250 TKUV11R S
1UL listed for field installation on TFC, TFJ, TFK, and THFK model 4 frames and trips (mfg. Code date J101 or later) and on THLC2, THLC4, TLB4.
2For replacement voltage suppressor on 120 Vac UVRs for F225 line, order Product Number 286A8062G1 for 120 Vac UVRs on all other breaker lines, order
Product Number 192A8300G1.
3"S" suffix for wires out the side of the breaker. For lead exit from back of breaker, replace suffix "S" with "B". "B" suffix not UL listed. For factory installation, contact
Customer Service Center.
4For TB1 with bolt-on limiters.
5Not UL listed.
Dummy Trip1
Breaker Type Product Number
E150 Internal accessories for these noninterchangeable
FJ225 breakers require factory-installed dummy trips.
JJ400 Automatically supplied when accessories are ordered.
JK400 TJKYT3 (two-pole, three-pole)
JK600 TJKYT36 (two-pole, three-pole)
KM800 TKMAYT3 (two-pole, three-pole)
1Not UL listed when field installed.
2Add "B" suffix for leads exit from back of breaker. For factory installation, contact
Customer Service Center.
3Not available with B suffix leads out back.
4Not available for two-pole TEB, TED. Order TEDBAR.
5Changes circuit breaker interrupting capacity to: 10kA @ 600 Vac, 22kA @ 480 Vac,
22kA @ 240 Vac, for TFC, TFJ, TFK and THFK only.
6UL listed for field installation.
7Mounts in center pole with leads out left side.
S E D A 2 4 A T 0030
1Adjustable Instantaneous with Tracking Short Time (Long Time established via Interchangeable Rating Plugs).
Note: This information is provided for interpreting product numbers (it should not be used to build product numbers).
SED, SEH, SEL, SEP2; 2-Pole, 150A, 480 Vac Max., (IEC 947-2: 160A, 415 Vac Max.)
Terminal Lugs for
Rating Plug Frame Front Connection (Cu/Al)
UL 489 IC @ 480 Vac
Adjustable Instantaneous 18kA 25kA 65kA 100kA
Ampere Trip Range Amps Product Current Product Product Product Product Product Wire
Rating Low High Number Sensor Number Number Number Number Number Range
15 43 182 SRPE30A15
20 58 254 SRPE30A20 30 SEDA24AT00303 SEHA24AT00303 SELA24AT00303 SEPA24AT00303
25 73 332 SRPE30A25
30 87 415 SRPE30A30
35 104 453 SRPE60A35
40 118 501 SRPE60A40
45 134 583 SRPE60A45 60 SEDA24AT00603 SEHA24AT00603 SELA24AT00603 SEPA24AT00603 12-3/0 Cu
50 148 637 SRPE60A50 TCAL18
12-3/0 Al
60 178 777 SRPE60A60
70 206 863 SRPE100A70
80 236 999 SRPE100A80 100 SEDA24AT0100 SEHA24AT0100 SELA24AT0100 SEPA24AT0100
90 267 1138 SRPE100A90
100 297 1280 SRPE100A100
110 328 1426 SRPE150A110
125 374 1640 SRPE150A125 150 SEDA24AT0150 SEHA24AT0150 SELA24AT0150 SEPA24AT0150
150 450 1991 SRPE150A150
SED, SEH, SEL, SEP2; 3-Pole, UL/CSA: 150A, 600 Vac Max., (IEC 947-2: 160A, 690 Vac Max.)
Terminal Lugs for
Rating Plug Frame Front Connection (Cu/Al)
UL 489 IC @ 480 Vac
Adjustable Instantaneous 18kA 25kA 65kA 100kA
Ampere Trip Range Amps Product Current Product Product Product Product Product Wire
Rating Low High Number Sensor Number Number Number Number Number Range
15 43 182 SRPE30A15
20 58 254 SRPE30A20 30 SEDA36AT00303 SEHA36AT00303 SELA36AT00303 SEPA36AT00303
25 73 332 SRPE30A25
30 87 415 SRPE30A30
35 104 453 SRPE60A35
40 118 501 SRPE60A40
45 134 583 SRPE60A45 60 SEDA36AT00603 SEHA36AT00603 SELA36AT00603 SEPA36AT00603
50 148 637 SRPE60A50 12-3/0 Cu
TCAL18
60 178 777 SRPE60A60 12-3/0 Al
70 206 863 SRPE100A70
80 236 999 SRPE100A80 100 SEDA36AT0100 SEHA36AT0100 SELA36AT0100 SEPA36AT0100
90 267 1138 SRPE100A90
100 297 1280 SRPE100A100
110 328 1426 SRPE150A110
125 374 1640 SRPE150A125 150 SEDA36AT0150 SEHA36AT0150 SELA36AT0150 SEPA36AT0150
150 450 1991 SRPE150A150
2SEL, SEP UL current limiting.
3When used with 15-50A Rating Plug, UL listed for HID (high intensity discharge).
SFH, SFL, SFP2; 2-Pole, UL/CSA: 250A, 480 Vac Max., (IEC 947-2: 250A, 415 Vac Max.)
Terminal Lugs for
Rating Plug Frame Front Connection (Cu/Al)
UL 489 IC @ 480 Vac
Adjustable Instantaneous 35kA 65kA 100kA
Trip Ampere Range
Ampere Product Current Product Product Product Product Wire
Rating Low High Number Sensor Number Number Number Number Range
70 205 700 SRPF250A70
80 235 800 SRPF250A80
90 265 900 SRPF250A90
100 295 1000 SRPF250A100
110 325 1100 SRPF250A110 8-350 Cu
125 370 1250 SRPF250A125 250 SFHA24AT0250 SFLA24AT0250 SFPA24AT0250 TCAL29
150 440 1500 SRPF250A150 8-350 Al
175 515 1750 SRPF250A175
200 590 2000 SRPF250A200
225 665 2250 SRPF250A225
250 736 2500 SRPF250A250
SFH, SFL, SFP2; 3-Pole, UL/CSA: 250A, 600 Vac Max., (IEC 947-2: 250A, 690 Vac Max.)
Terminal Lugs for
Rating Plug Frame Front Connection (Cu/Al)
UL 489 IC @ 480 Vac
Adjustable Instantaneous 35kA 65kA 100kA
Trip Ampere Range
Ampere Product Current Product Product Product Product Wire
Rating Low High Number Sensor Number Number Number Number Range
70 205 700 SRPF250A70
80 235 800 SRPF250A80
90 265 900 SRPF250A90
100 295 1000 SRPF250A100
110 325 1100 SRPF250A110 8-350 Cu
125 370 1250 SRPF250A125 250 SFHA36AT0250 SFLA36AT0250 SFPA36AT0250 TCAL29
150 440 1500 SRPF250A150 8-350 Al
175 515 1750 SRPF250A175
200 590 2000 SRPF250A200
225 665 2250 SRPF250A225
250 736 2500 SRPF250A250
2SFL, SFP UL current limiting.
Reference Publications
Available for download from www.geindustrial.com/publibrary
SF Breaker
Installation Instructions GEH-5591
Rating Plug GEH-5549
SF Breaker Accessories
Bell Alarm & Aux. Switch GEH-5593
Shunt Trip & UVR GEH-5551
Padlock Device GEJ-3056
Lug Kits GEJ-3045
Control Wire Lug Kit GEH-5882
STDA Flange Handle GEH-5314
STDA Operating Mechanism GEH-5684
TDR Operating Mechanism GEH-5609
TDM Operating Mechanism GEH-5611
Motor Operator GEH-5613
Cable Operator Mechanism GEH-6290
Operator Adapter Kits GEH-5688
Mechanical Interlock GEH-5615
Mounting Hardware Kits GEH-5659
SF Mounting Provisions
Plug-in Mounting Base GEH-4610
Back Connected Studs GEJ-3635
Outline Drawing 168D1103SH1
Series Ratings DET-008
Spectra RMS Circuit Breakers in Combination with
Cooper Bussman Distribution Block DET-781
SGD; 400A, 240 Vac Max., (IEC 947-2: 400A, 690 Vac Max.)
Rating Plug Frame Terminal Lugs for
Front Connection (Cu/Al)
240 Vac
Adjustable Instantaneous 65kA
Trip Ampere Range
Ampere Product Current Product Product4 Wire
Rating Low High Number Sensor Poles Number Number Range
125 380 1275 SRPG400A125 2-pole lug kit
150 455 1530 SRPG400A150 (2) 2/0-500 Cu
175 530 1785 SRPG400A175 2 SGDA22AT04003 TCLK265 or
200 605 2040 SRPG400A200 (1) 8-600 Cu
225 680 2295 SRPG400A225 400
250 755 2550 SRPG400A250 3-pole lug kit
300 905 3060 SRPG400A300 (2) 2/0-500 Al
3 SGDA32AT04003
350 1060 3570 SRPG400A350 TCLK365 or
400 1210 4080 SRPG400A400 (1) 8-600 Al
SGH, SGL, SGP5; 400A, 600 Vac Max., (IEC 947-2: 400A, 690 Vac Max.)
Terminal Lugs for
Rating Plug Frame Front Connection (Cu/Al)
UL 489 IC @ 480 Vac
Adjustable Instantaneous 35kA 65kA 100kA
Trip Ampere Range
Ampere Product Current Product Product Product Product4 Wire
Rating Low High Number Sensor Poles Number Number Number Number Range
125 380 1275 SRPG400A125 2-pole lug kit
150 455 1530 SRPG400A150 (2) 2/0-500 Cu
175 530 1785 SRPG400A175 2 SGHA26AT0400 SGLA26AT0400 SGPA26AT0400 TCLK265 or
200 605 2040 SRPG400A200 (1) 8-600 Cu
225 680 2295 SRPG400A225 400
250 755 2550 SRPG400A250 3-pole lug kit
300 905 3060 SRPG400A300 (2) 2/0-500 Al
3 SGHA36AT0400 SGLA36AT0400 SGPA36AT0400
350 1060 3570 SRPG400A350 TCLK365 or
400 1210 4080 SRPG400A400 (1) 8-600 Al
SGH, SGL5, SGP5; 600A, 600 Vac Max., (IEC 947-2: 630A, 690 Vac Max.)
Terminal Lugs for
Rating Plug Frame Front Connection (Cu/Al)
UL 489 IC @ 480 Vac
Adjustable Instantaneous 35kA 65kA 100kA
Trip Ampere Range
Ampere Product Current Product Product Product Product4 Wire
Rating Low High Number Sensor Poles Number Number Number Number Range
250 765 2530 SRPG600A250 2-pole lug kit
300 915 3035 SRPG600A300 (2) 2/0-500 Cu
2 SGHA26AT0600 SGLA26AT0600 SGPA26AT0600
350 1070 3545 SRPG600A350 TCLK265 or
400 1220 4050 SRPG600A400 600 (1) 8-600 Cu
450 1375 4555 SRPG600A450 3-pole lug kit
500 1525 5060 SRPG600A500 3 SGHA36AT0600 SGLA36AT0600 SGPA36AT0600 (2) 2/0-500 Al
600 1830 6075 SRPG600A600 TCLK365 or (1) 8-600 Al
3Rated 240 Vac max.
4Order one kit for either line or load end; two kits required for both.
5SGL, SGP UL current limiting.
Note: All Spectra breakers UL listed as HACR type. All Spectra breakers marked CE.
SGH, SGL2, SGP2; 100% UL Rated, 3-Pole: 400A, 600 Vac Max.; (IEC 947-2: 400A, 690 Vac Max.)
Terminal Lugs for
Rating Plug Frame Front Connection (Cu/Al)
UL 489 IC @ 480 Vac
Adjustable Instantaneous 35kAIC 65kAIC 100kAIC
Trip Ampere Range
Ampere Product Current Product Product Product Product1 Wire
Rating Low High Number Sensor Poles Number Number Number Number Range
125 380 1275 SRPG400A125
150 455 1530 SRPG400A150 (2) 2/0-500 Cu
175 530 1785 SRPG400A175 or
200 605 2040 SRPG400A200 (1) 8-600 Cu
225 680 2295 SRPG400A225 400 3 SGHH36AT0400 SGLL36AT0400 SGPP36AT0400 TCLK365
250 755 2550 SRPG400A250
300 905 3060 SRPG400A300 (2) 2/0-500 Al
350 1060 3570 SRPG400A350 or
400 1210 4080 SRPG400A400 (1) 8-600 Al
1Order one kit for either line or load end; two kits required for both.
2SGL, SGP UL current limiting.
SGH, SGL2, SGP2; 100% UL Rated, 3-Pole: 600A, 600 Vac Max.; (IEC 947-2: 630A, 690 Vac Max.)
Terminal Lugs for
Rating Plug Frame Front Connection (Cu/Al)
UL 489 IC @ 480 Vac
Adjustable Instantaneous 35kAIC 65kAIC 100kAIC
Trip Ampere Range
Ampere Product Current Product Product Product Product1 Wire
Rating Low High Number Sensor Poles Number Number Number Number Range
250 765 2530 SRPG600A250
300 915 3035 SRPG600A300 (2) 2/0-500 Cu
350 1070 3545 SRPG600A350 or (1) 8-600 Cu
400 1220 4050 SRPG600A400 600 3 SGHH36AT0600 SGLL36AT0600 SGPP36AT0600 TCLK365
450 1375 4555 SRPG600A450 (2) 2/0-500 Al
500 1525 5060 SRPG600A500 (1) 8-600 Al
600 1830 6075 SRPG600A600
Reference Publications
Available for download from www.geindustrial.com/publibrary
SG Breaker
Installation Instructions GEH-5663
Rating Plug GEH-5549
MVT & MVT Plus PM Rating Plugs GEH-5887
SG Breaker Accessories
Bell Alarm & Aux. Switch GEH-5593
Shunt Trip & UVR GEH-5551
Lug Kits GEJ-3052
Trip Unit Covers GEH-5664
Door Ring Interlock Catch Kits GEH-5662
STDA Flange Handle GEH-5314
STDA Operating Mechanism GEH-5684
TDR Operating Mechanism GEH-5654
TDM Operating Mechanism GEH-5653
Motor Operator GEH-5657
Cable Operator Mechanism GEH-6290
Cable Operators DEH-40467
Mechanical Interlock GEH-5697
SG Mounting Provisions
Plug-in Mounting Base GEH-5655
Back Connected Studs GEH-5665
Outline Drawing 208C1549SH1, 2, 3
Series Ratings DET-008
SKH, SKL, SKP; 800A, 600 Vac Max., (IEC 947-2:800A 690 Vac Max.)
Terminal Lugs for
Rating Plug Frame Front Connection (Cu/Al)
UL 489 IC @ 480 Vac
Adjustable Instantaneous 50kA 65kA 100kA
Trip Ampere Range
Ampere Product Current Product Product Product Product Wire
Rating Low High Number Sensor Poles Number Number Number Number Range
300 940 3015 SRPK800A300
400 1255 4015 SRPK800A400 2 SKHA26AT0800 SKLA26AT0800 SKPA26AT0800 (3) 3/0-500 Cu
500 1570 5020 SRPK800A500 800 TCAL81
600 1875 6195 SRPK800A600
700 2155 7420 SRPK800A700
3 SKHA36AT0800 SKLA36AT0800 SKPA36AT0800 (3) 3/0-500 Al
800 2440 8705 SRPK800A800
SKH, SKL, SKP; 1200A, 600 Vac Max., (IEC 947-2: 1250A, 690 Vac Max.)
Terminal Lugs for
Rating Plug Frame Front Connection (Cu/Al)
UL 489 IC @ 480 Vac
Adjustable Instantaneous 50kA 65kA 100kA
Trip Ampere Range
Ampere Product Current Product Product Product Product Wire
Rating Low High Number Sensor Poles Number Number Number Number Range
600 1825 6110 SRPK1200A600
700 2125 7125 SRPK1200A700 2 SKHA26AT1200 SKLA26AT1200 SKPA26AT1200 (4) 250-500 Cu
800 2430 8145 SRPK1200A800
1200 TCAL125
900 2735 9160 SRPK1200A900
1000 3040 10180 SRPK1200A1000
3 SKHA36AT1200 SKLA36AT1200 SKPA36AT1200 (4) 250-500 Al
1175 3574 11961 SRPK1200A1175
1200 3650 12215 SRPK1200A1200
SKH, SKL, SKP; 100% UL Rated, 3-Pole: 800A, 600 Vac Max.; (IEC 947-2: 800A, 690 Vac Max.)
Terminal Lugs for
Rating Plug Frame Front Connection (Cu/Al)
UL 489 IC @ 480 Vac
Adjustable Instantaneous 50kA 65kA 100kA
Trip Ampere Range
Ampere Product Current Product Product Product Product Wire
Rating Low High Number Sensor Poles Number Number Number Number Range
300 940 3015 SRPK800A300
400 1255 4015 SRPK800A400
(3) 3/0-500 Cu
500 1570 5020 SRPK800A500
800 3 SKHH36AT0800 SKLL36AT0800 SKPP36AT0800 TCAL81
600 1875 6195 SRPK800A600
(3) 3/0-500 Al
700 2155 7420 SRPK800A700
800 2440 8705 SRPK800A800
SKH, SKL, SKP; 100% UL Rated, 3-Pole: 1200A, 600 Vac Max.; (IEC 947-2: 100A, 690 Vac Max.)
Terminal Lugs for
Rating Plug Frame Front Connection (Cu/Al)
UL 489 IC @ 480 Vac
Adjustable Instantaneous 50kA 65kA 100kA
Trip Ampere Range
Ampere Product Current Product Product Product Product Wire
Rating Low High Number Sensor Poles Number Number Number Number Range
600 1825 6110 SRPK1200A600
700 2125 7125 SRPK1200A700 3 SKHH36AT1000 SKLL36AT1000 SKPP36AT1000
(4) 250-500 Cu
800 2430 8145 SRPK1200A800
1200 TCAL125
900 2735 9160 SRPK1200A900
(4) 250-500 Al
1000 3040 10180 SRPK1200A1000 3 SKHH36AT12001 SKLL36AT12001 SKPP36AT12001
1200 3650 12215 SRPK1200A1200
1100% UL rated SK1200 supplied with back-
connected assembly which increases breaker
depth. Refer to outline drawings for details.
Lugs not required
Note: All Spectra breakers UL listed as HACR type.
All Spectra breakers marked CE.
Reference Publications
Available for download from www.geindustrial.com/publibrary
SK Breaker
Installation Instructions GEH-5592
Rating Plug GEH-5549
MVT & MVT Plus PM Rating Plugs GEH-5887
SG Breaker Accessories
Bell Alarm & Aux. Switch GEH-5593
Shunt Trip & UVR GEH-5551
Lug Shields for SK1200 GEH-5699
Lug Shields for SKP GEH-5685
Trip Unit Covers GEH-5664
Mounting of Integral Handle GEH-5610
STDA Flange Handle GEH-5314
STDA Operating Mechanism GEH-5684
TDM Operating Mechanism GEH-5612
Coupling TDM Operating Mechanisms GEH-5873
Motor Operator GEH-5614
Cable Operator Mechanism GEH-6291
Handle Extension GEH-5648
Padlocking Device - Standard GEH-5877
Face Mounted Interlock GEH-5698
Mechanical Interlock GEH-5874
SK Mounting Provisions
Plug-in Mounting Base GEH-4342
Back Connected Studs GEJ-3619
Outline Drawing 208C1757SH1
Outline Drawing (1200A 100%) 168D1678SH2
Series Ratings DET-008
Other Features
UL Listed for reverse feed and HACR type (standard)
UL Listed 100% continuous current rating (optional)
UL Listed Current Limiting (optional on SG Frame)
Internal Accessories (Shunt Trip, Undervoltage Release, Auxiliary
Contacts, Bell Alarm) UL Listed for field installation and
common across the entire line of Spectra RMS breakers
Metering (Basic)
Metering (Advanced)
Modbus
Waveform Capture
Functions Accuracy and Description Protective Relays
PC 2
PC 1
Select the appropriate breaker frame on the following pages
taking into consideration the maximum ampere rating, the
interrupt rating, whether or not a 100% rating is required, RELT
Junction Breaker
standard protection functions (LSI, LSIG, LSIA), advanced protec- Box Cable
Communications
tion functions (Neut. Prot., ZSI, RELT), and advanced features and
communications (basic or advanced metering, communications,
TIM 1
TIM 1
(ZSI)
waveform capture, protective relays)
Select the rating plug and breaker lugs from the tables provided. From To
Select the required power management system accessories. Breaker Breaker
To Other Junction Boxes
Neutral
Select other accessories as required (such as an auxiliary switch Current
Sensor
or shunt trip).
When ordering, specify separate product numbers for each item Trip Unit Function Definitions
Long-Time (L) Adjustable current setting
Adjustable long-time delay - three curve shapes
Ordering Example (MVT I2t, CB and Fuse I4t)
Short-Time (S) Adjustable short-time pickup (can also be turned OFF)
SG600 ampere frame, standard load rating and 400 maximum Adjustable short-time delay - multiple slope options
ampere rating, 350 amp rating plug with line and load lugs. Trip I2t IN or OUT
Instantaneous (I) Adjustable instantaneous pickup
functions to include adjustable long-time (L), short-time (S), Ground Fault (G) Adjustable ground fault pickup
instantaneous (I), ground fault alarm (A), reduced energy let- Ground Fault Alarm (A) Adjustable ground fault delay - multiple slope options
through (RELT), and advanced metering, communications, with I2t IN or OUT
Control Power (CP) +24Vdc control power connection
waveform capture and protective relays. Metering and communi- Trip Indication Targets Standard
cations of voltage, current, power and breaker contact position Neutral Protection Adjustable current setting on Neutral: multiple of
are required. Local RELT enable is also required. The available Long-Time setting
ZSI (ST/GF/INST) Adjustable Zone Selective Interlock settings for
system voltage is 480/277 Vac 3 phase/4-wire with an available Short-Time, Ground Fault, and Instantaneous
fault current of 65kAIC. Power management accessories are to be RELT Adjustable Instantaneous: Reduced Energy
Let-Through mode
mounted on plates with all of the necessary fuse protection, Metering (basic) Amperes (A/kA) - Phase selectable
potential transformers, control power transformers, and required Metering (advanced) Current (A/kA) - Phase selectable
interconnect accessories. The required circuit breaker Product Voltage (V) - L-L or L-N and Phase selectable
Real Power (kW) - L-L or L-N
Number is SGLC3604L5R8. Reactive Power (kVAR) - L-L or L-N
Apparent Power (kVA) - L-L or L-N
Peak Power Demand (kW)
Description Product Number Energy (kWh/MWh)
Frequency (Hz)
Breaker Prefix SGLC3604L5_ _ Power Factor (%)
Adder 1 for R (RELT) Communications Modbus with user selectable address assignment
Adder 2 for 8 Compatible with EnerVista Viewpoint power system
(Adv Meter/Modbus/WFC/Relay) monitoring software
Complete Breaker SGLC3604L5R8 Waveform Capture Stores 8 cycles of data on trip or signal
Rating Plug GTP0350U0408 (COMTRADE file format)
Lug Kits (2) TCLK365 Protective Relay Functions Voltage Unbalance - pickup/delay/OFF
Auxiliary Switch SAUXGAB1 Current Unbalance - pickup/delay/OFF
RELT Switch Kit GTURSK Under Voltage - pickup/delay/OFF
Power Supply Plate SPSA480 Over Voltage - pickup/delay/OFF
Voltage Conditioner GMPU7 Power Reversal - pickup/delay/OFF
Advanced J-Box SDCJBBC Load Alarm - pickup (ON)/OFF
Distribution Cable Harness (2) SDCHA11
400A Neutral CT TSRG204
Other Features/Functions
HMI - Backlit LCD display & Ease of programming and viewing status/
5-button keypad metering displays, tactile feel
LED Status Indicator Visual display of trip units health
Visual pickup waring signal For quick diagnostics and pre-trip detection
Sealable LEXAN cover for Tamper resistant settings
tamper resistant settings
Test set jack for GTURSK test kit Fully integrated with GTURSK test kit
Long Time Thermal Memory For enhanced system protection
Input Relay1 Dedicated if RELT enabled or set to TRIP/OFF
Qty (2) Programmable Output Contacts1 RELT (dedicated)
Ground Fault Alarm
Overcurrent Trip
Protective Relay Trip
Load Alarm
Health Status
1Included on breakers with 20-pin output harness
Instantaneous Selectivity
System/Asset Protection
Diagnostics/Reliability
System Performance
Coordination
Arc Flash
Feature Benefit
Enhanced adjustability and flexibility Enhanced system protection via tight coordination with upstream
of time current curve shape, slope, and delay bands and downstream devices including fuses
Ground Fault Trip or Alarm Enhanced system and asset protection - especially for process driven applications
Zone Selective Interlock (ST/GF) System protection
Zone Selective Interlock (Instantaneous) Maximum system protection, coordination, and selectivity
Reduced Energy Let-Through Enhanced system and personnel protection
Protective Relay Functions Enhanced system and asset protection via a suite of protective relays
Neutral Protection Protection on heavy harmonic loads
Sealable LEXAN Trip Unit Cover Prevents unauthorized trip unit setting changes for maximum system, personnel,
and asset protection.
Long Time Thermal Memory Enhanced system protection
Input Relay1 System and asset protection via remote trip (dedicated if RELT enabled)
Programmable Output Contacts1 Maximize system uptime via signaling on GF alarm, overcurrent trip, protective relay trip,
load alarm or health status
Advanced Metering System performance monitoring and diagnostics of critical current, voltage,
and power characteristics
Modbus Communications System performance monitoring, reporting and diagnostics (compatible with
EnerVista Viewpoint power system monitoring software)
Test Set Jack for GTUTK20 Test Kit Maximize system uptime and enhanced diagnostics via the GTUTK20 test kit
Trip Indication Targets Visual Trip indication for quick diagnostic evaluation
Event Log Records last 10 trip events
Waveform Capture Enhanced diagnostic feature to maximize system uptime
HMI - Backlit LCD Display and 5-button Keypad Ease of programming and viewing status/metering displays
LED Status Indicator Enhanced diagnostic feature to maximize system uptime
(visual display of trip units health)
Visual Pickup Warning Signal For quick diagnostics and pre-trip detection
Spectra microEntelliGuard
Reference Publications
Spectra G Breaker w/
microEntelliGuard Trip Unit GEH-700
Spectra K Breaker w/
microEntelliGuard Trip Unit GEH-701
Universal Rating Plug DEH-41318
MET Sealable Cover Kits GEH-707
microEntelliGuard Trip Unit Users Manual GEH-702
microEntelliGuard Jump Start
Programming Instructions GEH-703
Distribution Cable Terminal Block (SDCTBA11) GEH-6257
Distribution Cable Terminal Blocks -
MET only (SDCTBA11C & SDCTBA22C) GEH-706
Distribution Cable Junction Box SDCJBB DEH-006
Advanced Distribution Cable Junction Box SDCJBBC GEH-704
Distribution Cable Harness (12-pin) GEH-6255
Distribution Cable Extension (12-pin) GEH-6256
Distribution Cable Extension - MET only (20-pin) GEH-705
Power Supply Plate GEH-6251
Power Supply Assembly GEH-6253
Voltage Conditioner GMPU GEH-6259
Voltage Conditioner SVCAA - OBSOLETE GEH-6254
Voltage Conditioner Plate SVCA - OBSOLETE GEH-6252
Voltage Module ADSVMA - OBSOLETE GEH-6250
GTU Digital Test Kit (GTUTK20) DEH-4568
Shunt Trip and UVR Instructions GEH-5551
Aux Switch and Bell Alarm GEH-5593
Accessories - Door Ring Interlock Catch Kits GEI-70594
TIM-1 Zone Selective Interlock Module GEK-64467
Standard
Frame Rating Voltage Protection Advanced Features &
Family (Amperes) Poles Rating Functions Communications
S = Spectra G = 600 3 = 3 poles 6 = 600V L3 = LSI2 X = Metering (Basic)
L4 = LSIG 2 = Metering (Basic) +
L5 = LSIA Modbus
Continuous
L7 = LSI-CP3 6 = Metering (Adv) +
Load Rating
Modbus +
C = Standard Waveform Capture
H = 100% Max Amps 8 = Metering (Adv) +
L = 100% 01 = 150A Modbus +
P = 100% 04 = 400A Waveform Capture +
06 = 600A Protective Relays
Interruption Rating
(kA @ 480V)
H = 35 Advanced Protection Functions
L = 65 X = None
P = 100 K = Neutral Protection
Z = ZSI (ST/GF)
T = ZSI (ST/GF/INST)
R = RELT
L = ZSI (ST/GF) + RELT
M = ZSI (ST/GF) +
Note: This information is provided for interpreting product numbers (it should not be used to build product numbers).
L = Long Time, S = Short Time, I = Instantaneous, G = Ground Fault, A = Ground Fault Alarm
Neutral Protection
ZSI = Zone Selective Interlocking, RELT = Reduced Energy Let-Through N = ZSI (ST/GF) + RELT +
Neutral Protection
2Without a Control Power connection, unless required by Advanced Protection Functions or Advanced Features
V = RELT + Neutral Protection
& Communications. P = ZSI (ST/GF/INST) + RELT
3With a Control Power connection. The only valid trailing product digits for L7 are XX.
S = ZSI (ST/GF/INST) +
Note: All Spectra breakers are UL listed as HACR type. Neutral Protection
W = ZSI (ST/GF/INST) + RELT +
Neutral Protection
1May require 24 Vdc control power and voltage sensing Notes: All Spectra breakers are UL listed as HACR type.
signals. Refer to pages 6-62 to 6-68. Neutral Protection requires a neutral current sensor. Refer to page 6-66.
2For grounded neutral systems (1 phase/3-wire or ZSI (Zone Selective Interlock) requires TIM1 ZSI module and 24 Vdc control power (refer to pages 6-62 to
3 phase/4-wire) a neutral current sensor is required. 6-66 for accessories).
Refer to page 6-66. RELT (Reduced Energy Let-Through), Modbus, Ground Fault Alarm and Waveform Capture options require
3For +24 Vdc Control Power Accessories refer to pages 24 Vdc control power
6-62 to 6-66. (refer to pages 6-62 to 6-66 for accessories).
Standard
Frame Rating Voltage Protection Advanced Features &
Family (Amperes) Poles Rating Functions Communications
S = Spectra K = 1200 3 = 3 poles 6 = 600V L3 = LSI3 X = Metering (Basic)
4 = 480V5 L4 = LSIG 2 = Metering (Basic) +
L5 = LSIA Modbus
Continuous
L7 = LSI-CP4 6 = Metering (Adv) +
Load Rating
Modbus +
C = Standard Waveform Capture
H = 100% Max Amps 8 = Metering (Adv) +
L = 100% 08 = 800A Modbus +
P = 100% 10 = 1000A2 Waveform Capture +
S = 100% 12 = 1200A Protective Relays
T = 100%
Interruption Rating
(kA @ 480V) Advanced Protection Functions
H = 50 X = None
L = 65 K = Neutral Protection
P = 100 Z = ZSI (ST/GF)
T = 65 Extended Instantaneous (Selective)5 T = ZSI (ST/GF/INST)
S = 100 Extended Instantaneous (Selective)5 R = RELT
L = ZSI (ST/GF) + RELT
M = ZSI (ST/GF) +
Note: This information is provided for interpreting product numbers (it should not be used to build product numbers).
Neutral Protection
L = Long Time, S = Short Time, I = Instantaneous, G = Ground Fault, A = Ground Fault Alarm
ZSI = Zone Selective Interlocking, RELT = Reduced Energy Let-Through N = ZSI (ST/GF) + RELT +
Neutral Protection
2Max Amps Option 10 only available on 100% rated breakers. V = RELT + Neutral Protection
3Without a Control Power connection, unless required by Advanced Protection Functions or Advanced Features
P = ZSI (ST/GF/INST) + RELT
& Communications.
4With a Control Power connection. The only valid trailing product digits for L7 are XX.
S = ZSI (ST/GF/INST) +
5SC, SS, TC and TT catalog codes are optimized for selectivity (extended instantaneous) and will carry a 480 Vac Neutral Protection
maximum voltage rating. W = ZSI (ST/GF/INST) + RELT +
Neutral Protection
Note: All Spectra breakers are UL listed as HACR type.
Required Accessories
MicroVersaTrip Plus MicroVersaTrip PM microEntelliGuard Feature Required Accessories
Neutral Protection Neutral CT
Terminal Board (or Junction Box)
Ground Fault (3 phase/4-wire or 1 phase/3-wire) Distribution Cable(s)
Ground Fault Alarm (3 phase/4-wire or 1 phase/3-wire) Power Supply Plate/Assy2 for GFA only1
Control Power Power Supply Plate/Assy2
Power Supply (Plate or Assy2)
Voltage Conditioner
Advanced Metering, Protective Relays
Terminal Board (or Junction Box)
Distribution Cable(s)
Power Supply Plate/Assy2
Terminal Board (or Junction Box)
Communications3
Distribution Cable(s)
Auxiliary Switch4
Power Supply Plate/Assy2
Terminal Board with ZSI (or Advanced Junction Box)
Zone Selective Interlock (ZSI)
Distribution Cable(s)
TIM-1 module
Power Supply Plate/Assy2
Reduced Energy Let-Through (RELT) Terminal Board with RELT (or Advanced Junction Box)
Distribution Cable(s)
Power Supply Plate/Assy2
Waveform Capture Terminal Board (or Advanced Junction Box)
Distribution Cable(s)
1Power supply required for Ground Fault Alarm only. 3MicroVersaTrip PM (Commnet), microEntelliGuard (Modbus)
2Requires fuse protection and other components - refer to accessory instruction sheet 4Requires Auxiliary Switch with gold-plated contacts
Power Supply
The Power Supply Plate is used to provide +24 Vdc control power to Spectra RMS
molded case circuit breakers with microEntelliGuard, MicroVersaTrip Plus and
MicroVersaTrip PM trip units via the Distribution Cable System. The Power Supply
Plate includes the Power Supply Assembly (product number SPSAA) as an integral
component and also includes fuse protection for AC source input. Supplemental +24 Vdc
input terminals are provided for backup control power applications. Not suitable for
400 Hz.
Description Voltage Rating Product Number
The Power Supply Plate is rated 24 watts 120 Vac SPSA120 Power Supply Plate
(+24 Vdc at 1.0 amperes) and has the maximum 208 Vac SPSA208
capacity to power a distribution Cable System 240 Vac SPSA240
consisting of 20 breakers and has a maximum 480 Vac SPSA480
system cable length of 40 feet. 600 Vac SPSA600
Voltage Conditioner
The Voltage Conditioner is used to provide voltage sensing signals to Spectra RMS
molded case circuit breakers with microEntelliGuard and MicroVersaTrip PM trip units
via the distribution cable system. The GMPU Voltage Conditioner includes internal power
transformers. It replaces the SVCA voltage conditioner plates and is DIN rail mountable.
The Voltage Conditioner requires a control power source of +24 Vdc to operate properly.
The Power Supply Assembly or Power Supply Plate can provide this required input. The
unit also requires AC direct voltage inputs from the AC source. A communications
network connection is provided. Not suitable for 400 Hz.
Voltage Conditioner
OBSOLETE
Voltage
Conditioner Plate Replacement
Product Number Voltage Rating and Service Type Comments Product Number Voltage Rating and Service Type
SVCA120Y 120 Vac Wye system Phase to Neutral potential
GMPU5 120, 208, 230 Vac systems
SVCA208Y 208 Vac Wye system Phase to Phase potential
SVCA240D 240 Vac Delta system Phase to Phase potential
GMPU6 240, 277, 340 Vac systems
SVCA277Y 277 Vac Wye system Phase to Neutral potential
SVCA480Y 480 Vac Wye system Phase to Phase potential
SVCA480D 480 Vac Delta system Phase to Phase potential GMPU7 400, 480, 600 Vac systems
SVCA600D 600 Vac Delta system Phase to Phase potential
Note: The Voltage Conditoner has the maximum capacity to power a Distribution Cable System consisting of 20 breakers and has a maximum system cable length of 40 feet.
Breakers with microEntelliGuard Trip Units Distribution Cable Terminal Block Connection Configurations
Breaker Harness Connector Configuration Terminal SDCTBA11 SDCTBA11C SDCTBA22C
Description 12-pin Connector 20-pin Connector 20-pin Connector
Circuit Breaker Catalog Digits 9 & 10
MicroVersaTrip & microEntelliGuard microEntelliGuard
L3 L4 L5 L7
Trip Unit Type microEntelliGuard only only
K2 SDCTBA11 SDCTBA11 SDCTBA22C n/a
POWER (+24Vdc)
K6 SDCTBA11 SDCTBA11 SDCTBA22C n/a
POWER (common)
K8 SDCTBA22C SDCTBA22C SDCTBA22C n/a
Communications +
KX SDCTBA11 SDCTBA11 SDCTBA11C n/a
Communications -
L2 SDCTBA22C SDCTBA22C SDCTBA22C n/a
Aux Switch (red)
L6 SDCTBA22C SDCTBA22C SDCTBA22C n/a
Aux Switch (white)
L8 SDCTBA22C SDCTBA22C SDCTBA22C n/a
Voltage - Ph A
LX SDCTBA22C SDCTBA22C SDCTBA22C n/a
Voltage - Ph B
M2 SDCTBA22C SDCTBA22C SDCTBA22C n/a
Voltage - Ph C
M6 SDCTBA22C SDCTBA22C SDCTBA22C n/a
Neutral CT (black)
M8 SDCTBA22C SDCTBA22C SDCTBA22C n/a
Neutral CT (white)
MX SDCTBA22C SDCTBA22C SDCTBA22C n/a
ZSI input +
N2 SDCTBA22C SDCTBA22C SDCTBA22C n/a
ZSI input -
N6 SDCTBA22C SDCTBA22C SDCTBA22C n/a
ZSI output +
N8 SDCTBA22C SDCTBA22C SDCTBA22C n/a
ZSI output -
NX SDCTBA22C SDCTBA22C SDCTBA22C n/a
RELT input +
P2 SDCTBA22C SDCTBA22C SDCTBA22C n/a
RELT input -
P6 SDCTBA22C SDCTBA22C SDCTBA22C n/a
RELT output +
Circuit Breaker Catalog Digits 11 & 12
E TE
RMS molded case circuit breakers with microEntelliGuard, MicroVersaTrip Plus and
O L
OBS E WITH
MicroVersaTrip PM trip units via the Distribution Cable System. The Voltage Conditioner
Assembly requires a control power source of +24 Vdc to operate properly (the Power
P AC V I C E
Supply Assembly or Power Supply Plate can provide this required input). The unit also
L
requires 120 Vac voltage inputs from the secondary of three 1-VA high accuracy
E
R D E
potential transformers (not included). The primary side of the potential transformers
U
GMP
must be fused with three, 1/2 ampere class CC fuses (not included). A communications
network connection is provided. Not suitable for 400 Hz.
Description Voltage Rating Product Number
Requires 120 Vac voltage inputs from the 120 Vac SVCAA
Voltage Conditioner Assembly
secondary of three 1.0 VA high accuracy
potential transformers
Note: the Voltage Conditioner Assembly has the maximum capacity to power a Distribution Cable System
consisting of 20 breakers and has a maximum system cable length of 40 feet.
Voltage Modules
The Voltage Module is used as a Spectra Series Switchboard component to provide
+24 Vdc control power to Spectra RMS molded case circuit breakers with
microEntelliGuard, MicroVersaTrip Plus and MicroVersaTrip PM trip units via the
E T E
Distribution Cable System. The Voltage Module also provides voltage sensing signals to
L
O T
O B S AC E M E N
Spectra RMS molded case circuit breakers with microEntelliGuard and MicroVersaTrip
PM trip units on the same Distribution Cable System. The Voltage Module contains both
PL
a Power Supply Plate and a Voltage Conditioner as integral components. It also includes
R E
fuse protection for the AC source input terminals (the modules pressure connectors
NO
which connect to the switchboard bus bars). A communication network connection is
provided as well as supplemental +24 Vdc input terminals for backup control power
applications (microEntelliGuard trip units communicate via Modbus; MicroVersaTrip PM
Voltage Module Exterior View
communicate via Commnet). Seven versions are available. Not suitable for 400 Hz.
Voltage Rating and Service Type Comments Product Number
120 Vac Wye system Phase to Neutral potential ADSVMA120Y
208 Vac Wye system Phase to Phase potential ADSVMA208Y
240 Vac Delta system Phase to Phase potential ADSVMA240D
277 Vac Wye system Phase to Neutral potential ADSVMA277Y
480 Vac Wye system Phase to Phase potential ADSVMA480Y
480 Vac Delta system Phase to Phase potential ADSVMA480D
600 Vac Delta system Phase to Phase potential ADSVMA600D
Note: The Voltage Module has the maximum capacity to power a Distribution Cable System consisting of 20
breakers and has a maximum system cable length of 40 feet.
Voltage Module Interior View
Accessory Mounting
All accessories mount in pouches accessible from a front cover. All breakers have a
left-side pouch and right-side pouch. The following combinations may be installed:
Left-Side Poucheither shunt trip or undervoltage release plus bell alarm. Left Side Pouch Right Side Pouch
Right-Side Pouchauxiliary switch (single or double pole).
Auxiliary Switch
Auxiliary switches provide remote indication of whether the circuit breaker main
contacts are opened or closed via open or closed SPDT switch elements.
Switch Number of Auxiliary Switch
Rating Switch Elements Product Number
5A @240 Vac/ 1 form C SAUXPAB1
0.5A @ 125 Vdc 2 form C SAUXPAB2
Gold-Plated Contacts 1 form C SAUXGAB1
0.5A @ 30V 2 form C SAUXGAB2
One each 2 form C SAUXGPAB2
of above types
Auxiliary Switch
Red
All accessory contacts shown
White with the circuit breaker in
Brown/white tripped position.
For remote tripping of breaker, use with momentary close contact. Not recommended for
use with latching relay contact since electronics in shunt trip will pulse power to the coil
if continuously energized, and breaker shunt tripping upon reclosure will be delayed 1-2
seconds at rated control voltage. (A short-circuit trip would be instantaneous.)
If maintained (latching relay) contact must be used and delayed shunt tripping is not
acceptable, use small bell alarm in series with control power for SE150 and SF250 frames
and auxiliary switch for SG600 and SK1200 breakers.
These devices are suitable for use with ground fault sensing and relaying equipment.
Maximum VA is 75. AC devices are UL listed for 50-60 Hz.
Undervoltage Release
The undervoltage release provides automatic circuit breaker tripping when there is a
power loss or major dip (to 35%-70% of rated voltage) in accessory control voltage. AC
devices are UL listed for 50-60 Hz. Product number SAUV1 may be used with time delay
unit SPUVTD (List Price $430.00, GO-245B) (delay 0.1 to 1.0 seconds), 120 Vac input,
125 Vdc output.
Note: UL listed at 200,000 AIC without internal accessories, 100,000 AIC with internally mounted accessories.
Purple
Yellow All accessory contacts shown
with the circuit breaker in
Brown tripped position.
Actuator
All Spectra circuit breakers are supplied with an actuator installed in the left-side pouch.
The actuator is removed when installing either a shunt trip or undervoltage release.
Description Product Number
Replacement Actuator SACTUATOR
Trip Curves
Trip Unit Rated Current (A) Trip Curve
15 DES-013
FB Breaker Markings
20 DES-014
cULus UL File E-11592 25 DES-015
HACR 15 to 100A 1, 2, 3 Pole 30 DES-016
HID 15 to 50A 1, 2, 3 Pole 35 DES-017
NAVAL 15 to 100A 1, 2, 3 Pole 40 DES-018
Cu/Al 60/75C 15 to 100A 1, 2, 3 Pole 45 DES-019
Current Limiting 15 to 100A 1, 2, 3 Pole 50 DES-020
60 DES-021
FB breakers are NOT marked LINE/LOAD and can be reverse fed. 70 DES-022
80 DES-023
90 DES-024
100 DES-025
Peak Current Curves DES-030
Peak I2t Curve DES-031
Interrupting Ratings
UL Listed Interrupting Ratings -
rms Symmetrical Amperes (in Thousands) AC Voltage
Type Ampere Rating Max AC Voltage No. Poles 240 277 347 480 600/347
1 35 35 22
FBV 15-100 600/347VAC 2 65 35 22
3 65 35 22
1 65 65 25
FBN 15-100 600/347VAC 2 150 65 25
3 150 65 25
1 100 100 35
FBH 15-100 600/347VAC 2 200 100 35
3 200 100 35
1 100 150 42
FBL 15-100 600/347VAC 2 200 150 42
3 200 150 42
UL Listed for field installation. Accessories are prewired from the factory with 36 inch long leads
(#18 AWG). Shunt trip wire leads are black and UVR wire leads are blue.
Bell Alarm
Contact
Configuration Contacts Contact Rating Wire leads Product No.
1 NO (Form A) Standard 5A @ 277 VAC, 0.3A @ 125 VDC #16 AWG FABAM10W
1 NC (Form B) Standard 5A @ 277 VAC, 0.3A @ 125 VDC #16 AWG FABAM01W
UL Listed for field installation. Accessories are prewired from the factory with 36 inch long leads. Reference
instruction sheet DEH-40324 for wire lead colors.
Auxiliary Switches
Contact Left Mount Right Mount
Configuration Contacts Contact Rating Wire leads Product No. Product No.
1 NO (Form A) Standard 5A @ 277 VAC, #16 AWG FAS10LW FAS10RW
0.3A @ 125 VDC
1 NC (Form B) Standard 5A @ 277 VAC, #16 AWG FAS01LW FAS01RW
0.3A @ 125 VDC
UL Listed for field installation. Accessories are prewired from the factory with 36 inch long leads. Reference
instruction sheet DEH-40324 for wire lead colors.
Mounting Locations
Padlocking Devices
Description Product No.
Padlock Fixed Toggle FB1PF
Padlock EUSERC Toggle FB1PE
FB 100 Dimensions
Poles A B C D E F G1 G2 H
1 3.88 (98.6) 3.28 (83.3) 1.06 (26.9) 1.36 (34.5) N/A N/A 5.11 (129.8) 5.01 (127.3) 6.45 (163.8)
2 3.88 (98.6) 3.28 (83.3) 1.06 (26.9) 2.74 (69.6) 0.69 (17.5) 1.38 (35.1) 5.11 (129.8) 5.01 (127.3) 6.45 (163.8)
3 3.88 (98.6) 3.28 (83.3) 1.06 (26.9) 4.11 (104.4) 1.38 (35.1) 1.38 (35.1) 5.11 (129.8) 5.01 (127.3) 6.45 (163.8)
"D" "A"
"D" "E" "E" "B"
"D" "F"
"E" "F" "C"
"G1"
"G1" "G1"
Reference Publications
Available for download from www.geindustrial.com/publibrary
1 Breaker Frame Rating FC Breaker
2 Rated Voltage Installation Instructions DEH-40463
3 FC Breaker Accessories
Breaker Frame Bell Alarm & Aux. Switch DEH-40324
4 Enclosed Rating Shunt Trip & Undervoltage Release DEH-40363
4
1 3 5 Product Description Lug Kits DEH-40532
5 Outline Drawings
2 6 Standards
6 FC 2-3 pole 10085772SH1
7 Interruption Capacity Series Ratings DET-008
7
Product Number
Trip Curves
Trip Unit Rated Current (A) Trip Curve
15 DES-013
20 DES-014
25 DES-015
30 DES-016
35 DES-017
40 DES-018
Main Standards 45 DES-019
50 DES-020
UL 489 60 DES-021
IEC 947 and associated EN Sections 70 DES-022
80 DES-023
90 DES-024
FC Breaker Markings 100 DES-025
Peak Current Curves DES-030
cULus UL File E-11592
Peak I2t Curve DES-031
HID 15-50A
HACR 15 to 100A
Cu/Al 60/75C 15 to 100A
Current Limiting 15 to 100A
Record Plus, Non-Automatic Circuit Breaker (Molded Case Switch), 600 VAC
2-Pole 3-Pole Lug Kit (3 per kit)
Ampere Rating Product No. Product No. Product No.
60 FCY206F060R FCY306F060R FCALK13
100 FCY206F100R FCY306F100R FCALK14
External Accessories
Electrical Operator Motor Drives,
Front Mounted Padlocking Devices
Motor Operator
Voltage Product No.
Description Product No.
120 VAC/125 VDC FCEMF3
220/240 VAC, 50/60 Hz FCEMF6 Padlock Fixed Toggle FC1PF
48 VDC FCEMFF Padlock EUSERC Toggle FC1PE
Plug-In Types
Type Description Product No.
Complete Kits 3 Pole - LSL - Horizontal Strap FCDDF1
Padlock
3 Pole - SLS - Horizontal Strap FCDDF2
3 Pole - LSL - Vertical Strap FCDDF3
3 Pole - SLS - Vertical Strap FCDDF4
Secondary Disconnect Secondary Disconnect Kit FCDSD
Secondary Disconnect - Base Part FCDSDP
Secondary Disconnect - Breaker Part FCDSDB
Mounting Plate Mounting Plate FCDMP
Hardware Kits
Description Product No. Plug-In Bases
Mounting screws for mounting plates with tapped holes, quantity 4 FCMSK3
(#8-32 x 2 7/8 screws with lockwashers)
Mounting screws for mounting plates with clearance holes, quantity 4 FCMSK4
(#8-32 x 3 screws with nuts lockwashers)
Nut plates (quantity 3) FCNP3
Nut plates (quantity 36) FCNPB
Plug-In Plate
FC 100 Dimensions A D
Frame A B C D E F G H B E E
FC 3.7 (29.1) 3.2 (81.3) .96 (24.4) 3.0 (76.2) 1.0 (25.4) 6.4 (162.6) 5.0 (127.0) 1.0 (25.4) C H
G F
Reference Publications
Available for download from www.geindustrial.com/publibrary
1 FE Breaker
Breaker Frame Rating Installation Instructions DEH-41640
2 Product Description Outline Drawing 10101247PV1
1 3 Standards & Markings FE Breaker Accessories
2
4 Bell Alarm & Aux Switch DEH-40324
Interrupting Ratings Shunt Trip & UVR DEH-40259
3 5 Lug Data & Torque Info Padlock Device DEH-41059
4
6 Product Number Lug Kits DEH-41054
Auxiliary Contacts DEH-40261
5 7 Push to Trip Panelboards
7 6 Spectra Power Panel - Plug-in Kits DEH-40402
Spectra Power Panel - Bolt-on Kits DEH-40425
Series Ratings DET-008
External Operators
STDA Style DEH-41014
TDM Style DEH-41025
Trip Curves
Main Standards Record Plus FE with PremEon S Trip - LSI Protections DES-115
Record Plus FE with PremEon S Trip - GF Protection DES-116
UL /cUL 489
Record Plus FE with PremEon S Trip - Mag only Motor Circuit Protector DES-117
HACR (heating, air conditioning, and refrigeration) Peak Current Curves DES-205
Naval Peak l2t Curve DES-206
Interrupting Ratings
UL Listed Interrupting Ratings -
rms Symmetrical Amperes (in Thousands) AC Voltage
Type Ampere Rating Max Voltage No. Poles 240 480
2 150 65
FEN 25-250A 480VAC
3 150 65
2 200 100
FEH 25-250A 480VAC
3 200 100
Cross Reference
SMR1 Equipped FE MCCB Rating Plug Amps PremEon Equipped MCCB
FE(N/H)(2/3)4AA0025R 20, 25 FE(N/H)(2/3)4DB025KF
FE(N/H)(2/3)4AA0060R 25, 30, 40, 50, 60 FE(N/H)(2/3)4DB060KF
FE(N/H)(2/3)4AA0125R 50, 60, 70, 80, 90, 100 ,110 ,125 FE(N/H)(2/3)4DB125KF
FE(N/H)(2/3)4AA0150R 70, 80, 90, 100, 110, 125, 150 FE(N/H)(2/3)4DB150KF
FE(N/H)(2/3)4AA0250R 100, 110, 125, 150, 175, 200, 225, 250 FE(N/H)(2/3)4DB250KF
F E N 3 4 D B 250 K F
Interruption Connection
Family Frame Size Rating (@480VAC) Poles Voltage Trip Unit Type Trip Unit Protection Trip Unit Amps Frame Amps Configuration
F = Record Plus E = 250A N = 65kA 2 = 2-Pole 4 = 480VAC D = PremEon S1 B = LI 025 = 25A K = 250A F = Standard,
H = 100kA in 3-Pole Frame C = LI 400 Hz 060 = 60A No Lugs
3 = 3 Pole G = LIG 125 = 125A
w/ Ground Fault 150 = 150A
250 = 250A
M =Mag-Only MCP
P = Mag-Only MCP
w/ Ground Fault
FE Breakers and MCP's equipped with the PremEon trip unit do not
use Rating Plugs to determine Amp rating. The trip unit features
an adjustment knob to set the Amp rating (Long-Time Pickup).
The knob is located behind a sealable cover and requires a
tamper-resistant Torx T15 tool. The tool is available through many
industrial supply companies. The maximum Amp rating of the
breaker frame is shown in the "Current Sensor" column below.
The available Amp rating settings (LT Pickup values), by sensor, are
as follows:
LI Trip Unit (With Tracking Short-Time) LIG Trip Unit (With Tracking Short-Time)
2-Pole Record Plus FE Breakers 2-Pole Record Plus FE Breakers
65kAIC @ 480 Vac 100kAIC @ 480 VAC 65kAIC @ 480 Vac 100kAIC @ 480 VAC
Current Sensor (A) Product Number Product Number Current Sensor (A) Product Number Product Number
25 FEN24DB025KF FEH24DB025KF 25 FEN24DG025KF FEH24DG025KF
60 FEN24DB060KF FEH24DB060KF 60 FEN24DG060KF FEH24DG060KF
125 FEN24DB125KF FEH24DB125KF 125 FEN24DG125KF FEH24DG125KF
150 FEN24DB150KF FEH24DB150KF 150 FEN24DG150KF FEH24DG150KF
250 FEN24DB250KF FEH24DB250KF 250 FEN24DG250KF FEH24DG250KF
UL Listed for field installation. Accessories are prewired from the factory with 36 inch long leads
(#18 AWG). Shunt trip wire leads are black and UVR wire leads are blue.
Bell Alarm
Contact
Configuration Contact Rating Wire leads Product No.
1 NO (Form A) 5A @ 277 VAC, #16 AWG FABAM10W
0.3A @ 125 VDC
1 NC (Form B) 5A @ 277 VAC, #16 AWG FABAM01W
0.3A @ 125 VDC
UL Listed for field installation. Accessories are prewired from the factory with 36 inch long leads. Reference
instruction sheet DEH-40324 for wire lead colors.
Auxiliary Switches
Contact Left Mount Right Mount
Configuration Contact Rating Wire leads Product No. Product No.
Bell Alarm
1 NO (Form A) 5A @ 277 VAC, #16 AWG FAS10LW FAS10RW Mechanism
0.3A @ 125 VDC Auxiliary
1 NC (Form B) 5A @ 277 VAC, #16 AWG FAS01LW FAS01RW Switch
0.3A @ 125 VDC
Auxiliary
UL Listed for field installation. Accessories are prewired from the factory with 36 inch long leads. Reference Switch
instruction sheet DEH-40324 for wire lead colors.
Lug Kits
Lug Kit Lug Kit w/
Lug Torque Single Lug (3 Lugs + Lug Cover) Control Wire Terminal
Ampere Rating Conductor Size (Max) Product No. Product No. Product No.
150A #14 - 3/0 Cu / Al 150 in-lb FCAL15 FCALK15 FCALK15LV
250A #8 - 250MCM Cu / #8 - 350MCM Al 275 in-lb FCAL16 FCALK16 FCALK16LV
Padlocking Device
Description Product Number
104.4
Other Accessories
Description Product Number
L
60.63 .30
52.60
73.5 [ 2.07 ]
77.0 [ 2.9 ]
81.0 [ 3.0 ]
[ 3.2 ]
108.36 .30
[ 4.27 .01 ] 111.76 .30
[ 4.400 .011 ]
35.0 R4.75
17.5 18.0
7.30
L
139.78 .30
R 125.53
170.10 .50
5.70 9.00
.50 4.95
3.08
18.00
19.00
15.60 .30
Reference Publications
Available for download from www.geindustrial.com/publibrary
FG Breaker
1 Breaker Frame Rating Installation Instructions DEH-41639
2 Product Description FG Breaker Accessories
1 2 3 Bell Alarm & Aux. Switch DEH-40324
3 Standards & Markings Shunt Trip & UVR DEH-40259
4 Interrupting Ratings Padlock Device DEH-41031
4
5 Lug Kits DEH-40404
5 Lug Data & Torque Info Auxiliary Contacts DEH-40261
6 6 Product Number Trip Unit Test Kit (FAT) DEH-40358
7 Push to Trip SMR2 Expansion Modules DEH-40408
SMR2 Modbus User Manual DEH-41181
7 SMR2 External Contact Module DEH-40409
Panelboards
Spectra Power Panel - Plug-in Kits - Single DEH-40420
Spectra Power Panel - Plug-in Kits - Double DEH-40419
Spectra Power Panel - Bolt-on Kits - Single DEH-40426
Spectra Power Panel - Bolt-on Kits - Double DEH-41047
Series Ratings DET-008
Outline Drawing 10085108SHI
Connection
Family Frame Size Interruption Rating Poles Voltage Trip Unit Type Trip Unit Protection Trip Unit/Frame Amps Configuration
F = Record Plus G = 600A (@480VAC) 2 = 2-Pole 6 = 600VAC D = PremEon S2 A = SMR2 standard 0250 = 250A SMR2 R0 = Standard No Lugs
N = 65kA in 3-Pole Frame K = SMR2 Z = SMR2 with ZSI 0400 = 400A SMR2 R1 = Line and Load Lugs3
H = 100kA 3 = 3-Pole B = LI 0600 = 600A SMR2 R2 = Load Lugs3
L = 150kA C = LI 400 Hz 250L = 250A PremEon R3 = Line Lugs3
P = 200kA G = LIG w/Ground Fault 400L = 400A PremEon
M = Mag-Only MCP 600M = 600A PremEon F = PremEon Standard
P = Mag-Only MCP No Lugs
PremEon S
FG Breakers and MCP's equipped with the PremEon S trip unit use an adjustment knob to set the Amp rating (LT Pickup). The maximum
Amp rating of the breaker frame is shown in the "Current Sensor" column below. The available Amp rating settings (LT Pickup values),
by sensor, are as follows:
Current Sensor (A) Amp Settings (LT Pickup)
250 80, 90, 100, 110, 125, 135, 150, 165, 175, 190, 200, 215, 225, 240, 250
400 125, 150, 175, 180, 200, 225, 240, 250, 275, 300, 325, 340, 350, 375, 400
600 175, 200, 225, 250, 300, 325, 350, 400, 425, 450, 475, 500, 550, 575, 600
Record Plus FG with SMR2 Trip Unit, Breaker Frames without ZSI and Fixed Rating Plugs
2-Pole
Fixed Rating Plug Breaker Frame
UL 489 65kA IC @ 480 Vac UL 489 100kA IC @ 480 Vac UL 489 150kA IC @ 480 Vac UL 489 200kA IC @ 480 Vac
Ampere Current
Rating Product No. Sensor Product No. Product No. Product No. Product No.
100A FGRM2K0100
110A FGRM2K0110
125A FGRM2K0125 R0 R0 R0 R0
150A FGRM2K0150 250 R1 R1 R1 R1
FGN26KA0250_ _ FGH26KA0250_ _ FGL26KA0250_ _ FGP26KA0250_ _
175A FGRM2K0175 R2 R2 R2 R2
200A FGRM2K0200 R3 R3 R3 R3
225A FGRM2K0225
250A FGRM2K0250
175A FGRM2L0175
200A FGRM2L0200
R0 R0 R0 R0
225A FGRM2L0225
400 R1 R1 R1 R1
250A FGRM2L0250 FGN26KA0400_ _ FGH26KA0400_ _ FGL26KA0400_ _ FGP26KA0400_ _
R2 R2 R2 R2
300A FGRM2L0300
R3 R3 R3 R3
350A FGRM2L0350
400A FGRM2L0400
300A FGRM2M0300
350A FGRM2M0350 R0 R0 R0 R0
400A FGRM2M0400 600 R1 R1 R1 R1
FGN26KA0600_ _ FGH26KA0600_ _ FGL26KA0600_ _ FGP26KA0600_ _
450A FGRM2M0450 R2 R2 R2 R2
500A FGRM2M0500 R3 R3 R3 R3
600A FGRM2M0600
3-Pole
Fixed Rating Plug Breaker Frame
UL 489 65kA IC @ 480 Vac UL 489 100kA IC @ 480 Vac UL 489 150kA IC @ 480 Vac UL 489 200kA IC @ 480 Vac
Ampere Current
Rating Product No. Sensor Product No. Product No. Product No. Product No.
100A FGRM3K0100
110A FGRM3K0110
125A FGRM3K0125 R0 R0 R0 R0
150A FGRM3K0150 250 R1 R1 R1 R1
FGN36KA0250_ _ FGH36KA0250_ _ FGL36KA0250_ _ FGP36KA0250_ _
175A FGRM3K0175 R2 R2 R2 R2
200A FGRM3K0200 R3 R3 R3 R3
225A FGRM3K0225
250A FGRM3K0250
175A FGRM3L0175
200A FGRM3L0200
R0 R0 R0 R0
225A FGRM3L0225 400 R1 R1 R1 R1
250A FGRM3L0250 FGN36KA0400_ _ FGH36KA0400_ _ FGL36KA0400_ _ FGP36KA0400_ _
R2 R2 R2 R2
300A FGRM3L0300
R3 R3 R3 R3
350A FGRM3L0350
400A FGRM3L0400
300A FGRM3M0300
350A FGRM3M0350 R0 R0 R0 R0
400A FGRM3M0400 600 R1 R1 R1 R1
FGN36KA0600_ _ FGH36KA0600_ _ FGL36KA0600_ _ FGP36KA0600_ _
450A FGRM3M0450 R2 R2 R2 R2
500A FGRM3M0500 R3 R3 R3 R3
600A FGRM3M0600
Adjustable Rating Plugs for Record Plus FG with SMR2 Trip Unit
Ampere Current Sensor
Poles Rating Product No. Rating
160A FGRN2K0160 250
250A FGRN2K0250
2-Pole 250A FGRN2L0250 400
400A FGRN2L0400
600A FGRN2M0600 600
160A FGRN3K0160
250
250A FGRN3K0250
3-Pole 250A FGRN3L0250
400
400A FGRN3L0400
600A FGRN3M0600 600
Record Plus FG with SMR2 Trip Unit, Breaker Frames with ZSI and Fixed Rating Plugs
2-Pole
Fixed Rating Plug Breaker Frame
UL 489 65kA IC @ 480 Vac UL 489 100kA IC @ 480 Vac UL 489 150kA IC @ 480 Vac UL 489 200kA IC @ 480 Vac
Ampere Current
Rating Product No. Sensor Product No. Product No. Product No. Product No.
100A FGRM2K0100 $106.00
110A FGRM2K0110
125A FGRM2K0125 R0 R0 R0 R0
150A FGRM2K0150 250 R1 R1 R1 R1
FGN26KZ0250_ _ FGH26KZ0250_ _ FGL26KZ0250_ _ FGP26KZ0250_ _
175A FGRM2K0175 R2 R2 R2 R2
200A FGRM2K0200 R3 R3 R3 R3
225A FGRM2K0225
250A FGRM2K0250
175A FGRM2L0175
200A FGRM2L0200
R0 R0 R0 R0
225A FGRM2L0225
400 R1 R1 R1 R1
250A FGRM2L0250 FGN26KZ0400_ _ FGH26KZ0400_ _ FGL26KZ0400_ _ FGP26KZ0400_ _
R2 R2 R2 R2
300A FGRM2L0300
R3 R3 R3 R3
350A FGRM2L0350
400A FGRM2L0400
300A FGRM2M0300
350A FGRM2M0350 R0 R0 R0 R0
400A FGRM2M0400 600 R1 R1 R1 R1
FGN26KZ0600_ _ FGH26KZ0600_ _ FGL26KZ0600_ _ FGP26KZ0600_ _
450A FGRM2M0450 R2 R2 R2 R2
500A FGRM2M0500 R3 R3 R3 R3
600A FGRM2M0600
3-Pole
Fixed Rating Plug Breaker Frame
UL 489 65kA IC @ 480 Vac UL 489 100kA IC @ 480 Vac UL 489 150kA IC @ 480 Vac UL 489 200kA IC @ 480 Vac
Ampere Current
Rating Product No. Sensor Product No. Product No. Product No. Product No.
100A FGRM3K0100
110A FGRM3K0110
125A FGRM3K0125 R0 R0 R0 R0
150A FGRM3K0150 250 R1 R1 R1 R1
FGN36KZ0250_ _ FGH36KZ0250_ _ FGL36KZ0250_ _ FGP36KZ0250_ _
175A FGRM3K0175 R2 R2 R2 R2
200A FGRM3K0200 R3 R3 R3 R3
225A FGRM3K0225
250A FGRM3K0250
175A FGRM3L0175
200A FGRM3L0200
R0 R0 R0 R0
225A FGRM3L0225 400 R1 R1 R1 R1
250A FGRM3L0250 FGN36KZ0400_ _ FGH36KZ0400_ _ FGL36KZ0400_ _ FGP36KZ0400_ _
R2 R2 R2 R2
300A FGRM3L0300
R3 R3 R3 R3
350A FGRM3L0350
400A FGRM3L0400
300A FGRM3M0300
350A FGRM3M0350 R0 R0 R0 R0
400A FGRM3M0400 600 R1 R1 R1 R1
FGN36KZ0600_ _ FGH36KZ0600_ _ FGL36KZ0600_ _ FGP36KZ0600_ _
450A FGRM3M0450 R2 R2 R2 R2
500A FGRM3M0500 R3 R3 R3 R3
600A FGRM3M0600
Adjustable Rating Plugs for Record Plus FG with SMR2 Trip Unit
Ampere Current Sensor
Poles Rating Product No. Rating
160A FGRN2K0160 250
250A FGRN2K0250
2-Pole 250A FGRN2L0250 400
400A FGRN2L0400
600A FGRN2M0600 600
160A FGRN3K0160
250
250A FGRN3K0250
3-Pole 250A FGRN3L0250
400
400A FGRN3L0400
600A FGRN3M0600 600
UL Listed for field installation. Accessories are prewired from the factory with 36 inch long leads
(#18 AWG). Shunt trip wire leads are black and UVR wire leads are blue.
355% pickup as required for use with External Ground Fault Protection.
Bell Alarm
Mechanisms Trip Units
Contact
Configuration Contacts Contact Rating Wire leads Product No. Product No.
1 NO (Form A) Standard 5A @ 277 VAC, #16 AWG FABAM10W FABAT10W
0.3A @ 125 VDC
1 NC (Form B) Standard 5A @ 277 VAC, #16 AWG FABAM01W FABAT01W
0.3A @ 125 VDC
UL Listed for field installation. Accessories are prewired from the factory with 36 inch long leads. Reference
instruction sheet DEH-40324 for wire lead colors.
Auxiliary Switches
Left Mount Right Mount
Contact
Configuration Contacts Contact Rating Wire leads Product No. Product No.
1 NO (Form A) Standard 5A @ 277 VAC, #16 AWG FAS10LW FAS10RW
0.3A @ 125 VDC
1 NC (Form B) Standard 5A @ 277 VAC, #16 AWG FAS01LW FAS01RW
0.3A @ 125 VDC
UL Listed for field installation. Accessories are prewired from the factory with 36 inch long leads. Reference
instruction sheet DEH-40324 for wire lead colors.
Shunt Trip or
Undervoltage
Release
Mounting Locations
Padlocking Device
Description Product No.
Padlocking EUSERC Toggle FG1PE
Lug Kits
Top
Torque Strip Length
Pole/Lugs Location Wire Type Wire-Lug Lug-Strap Top Bottom Product No.
2 Top #8-400kcmil Cu, #8-#4 AWG Cu/Al 200 lb-in Bottom
#6-500kcmil Al 275 lb-in (31 N-m) (23 N-m) 7/8 1 5/8 FCALK218H
Bottom #2/0-600kcmil Cu/Al #3 AWG-600kcmil Cu/Al 200 lb-in
375 lb-in (42 N-m) (23 N-m)
3 Top #8-400kcmil Cu, #8-#4 AWG Cu/Al 200 lb-in
#6-500kcmil Al 275 lb-in (31 N-m) (23 N-m) FCALK218H/FCALK318H
7/8 1 5/8 FCALK318H
Bottom #2/0-600kcmil Cu/Al #3 AWG-600kcmil Cu/Al 200 lb-in
375 lb-in (42 N-m) (23 N-m)
Other Accessories
Product No.
Rating Plug Removal Tool (SMR1 and SMR2 only) FAR
Breaker External Test Kit (SMR1 and SMR2 only) FAT
Lug Cover Kit FGH1LCK
Hardware Kit (Tapped Holes) FGMSK1
Hardware Kit (Through Holes) FGMSK2
Terminal Shield Fin Cover FGJS3
Nut Plate / Terminal Shoe FGJN3
Dimensions (in.)
FG 600 Dimensions
Molded Case Switches Nonautomatic Trip, Includes Cu/Al line and load lugs. For optional lugs, see page 6-103 and 6-104.
Type Ampere Rating Number of Poles Voltage Rating Product Number
TEB 100 1 120 Vac, 125 Vdc TEB111Y1004
TEB 100 2 240 Vac, 250 Vdc TEB122Y1004
TEB 100 3 240 Vac TEB132Y1004
TEB 100 3 240Vac TEB132YT1009
TED 100 1 277 Vac, 125 Vdc TED113Y1004
TED 100 2 480 Vac, 250 Vdc TED124Y1004
TED 100 3 480Vac, 250Vdc TED134YT1009
TED 100 3 600Vac TED136YT1009
TED 100 3 600Vac TED136YT100A10
TED 150 2 480 Vac, 250 Vdc TED124Y1504,5
TED 150 3 480Vac, 250Vdc TED134YT1509
TED 150 3 600Vac TED136YT1509
TFJ 225 2 600 Vac TFJ226Y2254,6,11
TFJ 225 3 600 Vac TFJ236Y2256,11
TJJ 400 2 600 Vac, 250 Vdc TJJ426Y4007
TJJ 400 3 600 Vac TJJ436Y4007
Features
Suitable for Reverse Feed
UL Recognized File E-11592
CSA Certified LR 40350
IEC 947-2 690 Vac Max.
SE 150 160 Ampere Max.
SF250 250 Ampere Max.
SG600 630 Ampere Max.
SK1200 1250 Ampere Max.
UL Current Limiting
High Interrupting Capacity Spectra RMS Motor Circuit ProtectorsSE150 Line 3-Pole
Terminal Lugs for
Rating Plug Frame Front Connection (Cu/Al)
65kAIC @480 Vac 100kAIC @480 Vac
Adjustable Instantaneous
Ampere Trip Ampere Range Product Current Product Product Product Wire
Rating Low High Number Sensor Number Number Number Range
3 11 39 SRPE7A3
7 SELA36AI0007 SEPA36AI0007 TCAL18
7 22 90 SRPE7A7
15 43 182 SRPE30A15
20 58 254 SRPE30A20 30 SELA36AI0030 SEPA36AI0030 TCAL18
25 73 332 SRPE30A25
30 87 415 SRPE30A30 14-3/0 Cu
40 118 501 SRPE60A40
50 148 637 SRPE60A50 60 SELA36AI0060 SEPA36AI0060 TCAL18
60 178 777 SRPE60A60 12-3/0 Al
70 206 863 SRPE100A70
80 236 999 SRPE100A80 100 SELA36AI0100 SEPA36AI0100 TCAL18
90 267 1138 SRPE100A90
100 297 1280 SRPE100A100
110 328 1426 SRPE150A110
125 374 1640 SRPE150A125 150 SELA36AI0150 SEPA36AI0150 TCAL18
150 450 1991 SRPE150A150
1Per UL 489, interruption ratings are not printed on the product label (interruption ratings are established based on a tested combination of the motor circuit protector and a
properly sized overload relay and contactor).
Accessories: See pages 6-39 to 6-44, 6-67 to 6-69 and 6-94 to 6-106.
Standard Capacity Mag Break Motor Circuit ProtectorsType TJC 3-Pole
30kAIC @480 Vac
Adjustable Instantaneous Complete Breaker (includes line and load lugs)
Trip Ampere Range Product
Ampere Rating Low High Number
330 1100 TJC36400E
550 1670 TJC36400F
400
1000 3300 TJC36400G
1200 4000 TJC36400B
1000 3300 TJC36600G
600
1800 6000 TJC36600H
High Interrupting Record Plus FE Motor Circuit Protectors - FE 250 Line with PremEon S
Mag-Only Motor Circuit Protector (With Tracking Short-Time) Mag-Only Motor Circuit Protector Plus Ground Fault (With Tracking Short-Time)
2-Pole Record Plus FE MCPs 2-Pole Record Plus FE MCPs
65kAIC @480 Vac 100kAIC @480 Vac 65kAIC @480 Vac 100kAIC @480 Vac
Current Sensor (A) Product Number Product Number Current Sensor (A) Product Number Product Number
25 FEN24DM025KF FEH24DM025KF 25 FEN24DP025KF FEH24DP025KF
60 FEN24DM060KF FEH24DM060KF 60 FEN24DP060KF FEH24DP060KF
125 FEN24DM125KF FEH24DM125KF 125 FEN24DP125KF FEH24DP125KF
150 FEN24DM150KF FEH24DM150KF 150 FEN24DP150KF FEH24DP150KF
250 FEN24DM250KF FEH24DM250KF 250 FEN24DP250KF FEH24DP250KF
High Interrupting Record Plus FG Motor Circuit Protectors - FG 600 Line with PremEon S
Mag-Only Motor Circuit Protector (With Tracking Short-Time)
2-Pole Record Plus FG Breakers
65kAIC @ 480 Vac 100kAIC @ 480 Vac 150kAIC @ 480 Vac 200kAIC @ 480 Vac
Current Sensor (A) Product Number Product Number Product Number Product Number
250 FGN26DM250LF FGH26DM250LF FGL26DM250LF FGP26DM250LF
400 FGN26DM400LF FGH26DM400LF FGL26DM400LF FGP26DM400LF
600 FGN26DM600MF FGH26DM600MF FGL26DM600MF FGP26DM600MF
Mag-Only Motor Circuit Protector Plus Ground Fault (With Tracking Short-Time)
How to Order
Use the circuit breaker mounting zone dimension table to determine the correct cable
length for the application and ensure that the 3-inch minimum bending radius is not
violated. Select the breaker mounted mechanism, operating cable and handle mecha-
nism below. Order as separate components.
Publication References
Breaker types E150, SE150, SF250, SG600 GEH-6290
Breaker type SK1200 GEH-6291
Type STDA Flange Handles and Variable Depth Operating Flange Stiffener Kit or Extended Length Drive Rod,
Mechanisms Product Number TDSR
Designed to meet automotive duty specifications Provides rigid 3/8-inch diameter rod between STDA handle mount-
NEMA 12/13 and 4/4X UL Component Recognized components, ing surface (flange or center mullion) and operating mechanism
File E-57253l CSA LR 10263 when STDA handle would otherwise not be rigidly supported.
For right or left hand flange mounting field convertible
Mounting dimensions to fit standard flange enclosures 8 inches Rod length is 22 inches and my be cut to appropriate length. Also
24 inches deep used as extended-length drive rod for SDOM1A and SDOM3 when
Detailed installation instructions standard 16 inch rod is not long enough. (Operating mechanism
Superior strength Product Number SDOM6 for SK1200 includes two 22" unique
3/8-16x22 inch flange stiffener rods, Product Number TDSR and
drive rod.)
Flange Handle Construction
Rugged die cast housing with provisions for locking in OFF Operating Flange Extended
position with up to three 3/16-inch to 5/16-inch padlocks Mechanism Stiffener Kit Drive Rod
Product Number Product Number Product Number
O-ring seals for dirt-tight/oil-tight duty SDOM1A, SDOM3,
Gusseted, 3/32-inch thick double-sided steel handle with large, TDOM1A through TDOM3
TDSR TDSR
Product Number STDA1 (6 inch) and STDA2 (10 inch) flange series
handles are interchangeable. While the SE150 through SG600 Extended Drive Stud, Product Number TDS1, TDS2
operating mechanisms can be easily operated with the 6-inch
STDA1 handle, the 10-inch STDA2 may be used to obtain lower This optional drive study permits locating the operating mecha-
operating force and/or to provide a proportionally larger handle nism 1-5/16 inches farther to the left (When flange handle is on
on large enclosures. STDA3 and STDA3X can be used only with right side) or to the right (when handle is on the left side) to
SDOM6 (for SK1200) operating mechanism. accommodate specific mounting restrictions. Not suitable for use
with SDOM4, SDOM6, TDOM4 and TDOM5 operating mechanisms.
NEMA 12/13 NEMA 4/4X Nominal Installation Drilling
Flange Handle Flange Handle Length Instruction Template Operating Mechanism Extended Drive Stud
Product Number Product Number Inches Number Number Product Number Product Number
STDA1 STDA1X 6 SDOM1A, SDOM3,
TDS1
STDA2 STDA2X 10 GEH-5314 GEH-5314 TDOM1A through TDOM3
STDA3 STDA3X 10 TDOM6, TDOM7 TDS2
Publication References
Instructions:
Door Hardware GEH-5322
Auxiliary Contact Kit GEH-5323
Flange Stiffener Kit or Extended Length Drive Rod GEH-5324
Extended Drive Stud GEH-5325
Operating Mechanism:
SDOM1A through SDOM4, SDOM6 GEH-5684
TDOM1A through TDOM1D GEH-5315
TDOM3 GEH-5317
TDOM4 and TDOM5 GEH-5318
TDOM6 and TDOM7 GEH-5319
Product Number
TRTOOL
Special Calibration
Contact GE sales office for availability. May void UL listing status.
NEMA Type 1
For Enclosures with
Certifications Product Number Suffix Options (Mounting) For 3P4W Enclosures Ground Fault Protection
Max. Surface,
Ampere No. of UL cUL Blank Neutral Neutral Product Neutral Sensor
Rating Frame Type Poles SE cUL SE1 CSA Prefix Flush Surface End Wall2 Product Number Number3 for Ground Fault
70 THQL, TXQL, THQL-GF 1, 2, 3 TQL70_4 F S Included
100 THQL, TXQL, THQL-GF 1, 2, 3 TQL100_4 F S Included
125 THQL 2 TQL125_ F S Included
100 THQC, THHQC, TXQC 1, 2, 3 TQC100_4 F S Included
100 SE150, THED, TED, TEB 2, 3 TE100_ F S SB Included
150 SE150, THED, TED 2, 3 TE150_ F S SB Included
225 TQD, THQD 2, 3 TQD225_ F S - Included
250 SF250 2, 3 SF250_ F S SB TNIA2255
FEGS0025
FEGS0060
250 FE250 2, 3 FE250_ F S SB TNIA2255 TNIA250EGF FEGS0125
FEGS0150
FEGS0250
400 TJD, TJJ, TJK, THJK 2, 3 TJ400_6 F S - TNIA400
600 TJK, THJK 2, 3 TJ600_ F S - TNIA600
TSRG201
400 SG400 2, 3 SG400_ F S SB TNIA400 TNIA400VG
TSRG204
600 SG600 2, 3 SG600_ F S SB TNIA600 TNIA600VG TSRG206
FGGS0250
600 FG600 2, 3 FG600_ F S SB TNIA400 TNIA400GGF
FGGS0400
TNIA600
TNIA600GGF FGGS0600
TNIA400
TNIA600 TNIA800G TSKG408
1200 SK1200 2, 3 TK4V1200_7, 8 F S SB TNIA800 TSKG410
TNIA1200G
TNIA1200 TSKG412
TNIAC1200
1 cUL Listed - Suitable for use as service equipment.
2 Enclosures with blank end walls feature closed enclosure instantaneous adjustment.
3 Neutral for ground fault required to mount neutral sensor in enclosure.
4 3-Pole breakers with an accessory cannot be installed in these enclosures.
5 For 250A rating, use copper cable only.
6 Suitable for parallel 250 kcmil maximum. If larger cable is required, use 600A enclosure.
7 Not suitable for 100% rated 1200A SK breakers.
8 Suitable for parallel 500 kcmil maximum.
NEMA Type 3R
For Enclosures with
Max. Certifications For 3P4W Enclosures Ground Fault Protection
Ampere No. of UL cUL Product Neutral Neutral Neutral Sensor
Rating Frame Type Poles SE cUL SE1 CSA Number10 Product Number Product Number2 for Ground Fault
70 THQL, TXQL, THQL-GF 1, 2, 3 TQL70R3 Included
100 THQL, TXQL, THQL-GF 1, 2, 3 TQL100R3 Included
125 THQL 2 TQL125R Included
100 THQC, THHQC, TXQC 1, 2, 3 TQC100R3 Included
100 SE150, THED, TED, TEB 2, 3 TE100R Included
150 SE150, THED, TED 2, 3 TE150R Included
225 TQD, THQD 2 TQD225NR9 Included
225 TQD, THQD 2, 3 TQD225R Included
250 SF250 2, 3 TF225R TNIA2254
FEGS0025
FEGS0060
250 FE250 2, 3 FE250R TNIA2254 TNIA250EGF FEGS0125
FEGS0150
FEGS0250
400 TJD, TJJ, TJK, THJK 2, 3 TJ400R5 TNIA400
600 TJK, THJK 2, 3 TJ600R TNIA600
TSRG201
400 SG400 2, 3 SG400R TNIA400 TNIA400VG
TSRG204
600 SG600 2, 3 SG600R TNIA600 TNIA600VG TSRG206
TNIA400 FGGS0250
TNIA400GGF
600 FG600 2, 3 FG600R TNIA600 FGGS0400
TNIA600GGF FGGS0600
TNIA400
TNIA600 TNIA800G TSKG408
1200 SK1200 2, 3 TK4V1200R6, 7 TNIA800 TSKG410
TNIA1200G
TNIA1200 TSKG412
TNIAC1200
NEMA Type 12
For Enclosures with
Max. Certifications Product Number Suffix Options (Mounting) For 3P4W Enclosures Ground Fault Protection
Ampere No. of cUL With Knock Without Neutral Neutral Product Neutral Sensor
Rating Frame Type Poles UL cUL SE1 CSA Prefix Outs Knock Outs Product Number Number2 for Ground Fault
100 THED, TED, TEB 3 TE100_ D J Included
100 SE150 2, 3 SE100_ D J Included
250 SF250 2, 3 SF250_ D J TNIA2254
400 TJD, TJJ, TJK, THJK 2, 3 TJ400_3 J TNIA400
TNIA400
600 TJK, THJK 2, 3 TJ600_ J
TNIA600
TSRG201
400 SG400 2, 3 SG400_ D J TNIA400 TNIA400VG
TSRG204
600 SG600 2, 3 SG600_ J TNIA600 TNIA600VG TSRG206
TNIA400
TNIA600 TNIA800G TSKG408
1200 SK1200 2, 3 SK1200_5, 6 J TNIA800 TSKG410
TNIA1200G
TNIA1200 TSKG412
TNIAC1200
1 cUL Listed - Suitable for use as service equipment.
2 Neutral for ground fault required to mount neutral sensor in enclosure.
3 Suitable for parallel 250 kcmil maximum. If larger cable is required, use 600A enclosure.
4 For 250A rating, use copper cable only.
5 Not suitable for 100% rated 1200A SK breakers.
6 Suitable for parallel 500 kcmil maximum.
TC150
Max. Ampere Rating Lug Wire Size (Cu-Al) AWG/kcmil Standard Package Product Number
100 14-1/0 Cu, 12-1/0Al 1 TNI100
225 1-300 1 TNIA2251
250 1-300 1 TNIA250EGF1, 3
400 (2) 1/0-250 or (1) 4-600 1 TNIA400
400 (2) 1/0-250 or (1) 4-600 1 TNIA400VG2
400 (2) 1/0-250 or (1) 4-600 1 TNIA400GGF3
600 (2) 2/0-500 1 TNIA600
600 (2) 2/0-500 1 TNIA600VG2
600 (2) 2/0-500 1 TNIA600GGF3
800 (3) 250-500 1 TNIA800
800 (3) 250-350 Cu or (3) 250-500 Al 1 TNIA800G2
1200 (4) 250-350 Cu or (4) 250-500 Al 1 TNIA1200
1200 (4) 250-350 Cu or (4) 250-500 Al 1 TNIA1200G2
1200 (4) 250-400 Cu Only 1 TNIAC1200
1For 250A rating, use copper cable only
2Neutral required for Spectra Circuit Breakers with ground fault.
3Neutral required for Record Plus Circuit Breakers with ground fault.
Ground Kits
1 1 1 1 1 1 1 1 1 1 1
Conduit 11/4 11/4 11/4 11/4 11/4 11/4 11/4 11/4 11/4 11/4 11/4
Size
11/2 11/2 11/2 11/2 11/2 11/2 11/2 11/2 11/2 11/2 11/2
(Inches)
2 2 2 2 2 2 2 2 2 2 2
21/2 21/2 21/2 21/2 21/2 21/2 21/2 21/2
3 3 3 3 3 3 3
31/2 31/2 31/2 31/2 31/2
4
Fig. 3 Fig. 4
Low Voltage Power and DC Circuit Breakers Insulated Case Circuit Breakers
EntelliGuard G Low Voltage Power Circuit Breakers ...........8-2 Power Break II ...........................................................................8-91
Overview and Functions ........................................................................8-2 Features .......................................................................................................8-91
EntelliGuard TU Trip Units....................................................................8-4 Construction Options .............................................................................8-92
Product Nomenclature ............................................................................8-5 EntelliGuard TU Trip Unit Features................................................8-93
Cassettes Nomenclature......................................................................8-11 Power+ Trip Unit Features...................................................................8-94
Accessories.................................................................................................8-13 Enhanced MicroVersaTrip Trip Unit Features ..........................8-95
WavePro Circuit Breakers with EntelliGuard TU, Trip Unit Characteristics .......................................................................8-96
Power+, Enhanced MicroVersaTrip Plus and Power Break II Nomenclature System ........................................8-99
MicroVersaTrip PM Trip Unit Systems ............................8-24 Product Number Nomenclature System ...................................8-104
WavePro Low Voltage Power Circuit Breakers .....................8-26 Interrupting Capacity and Withstand Ratings ........................8-108
OEM Substructures and Substructure Accessories .............8-40 How to Order...........................................................................................8-109
Trip Units......................................................................................8-49 Frame Selection (Old Structure) .....................................................8-110
Overview EntelliGuard TU, Power+ and Trip Unit Selection.................................................................................8-111
Enhanced MicroVersaTrip .............................................................8-49 Enhanced MicroVersaTrip Rating Plug Selection ................8-113
Product Number Nomenclature System ......................................8-55 Stationary and Draw-out Switch Selection ..............................8-114
Trip Unit Conversion Kits Introduction...................................8-66 Stationary and Draw-out Breaker Accessories ......................8-115
Overview EntelliGuard TU, and Stationary Breaker Mounting Kits .................................................8-121
MicroVersaTrip PM Conversion Kits...........................................8-67 Stationary Breaker Mounting Kits,
Remanufactured MVT Trip Unit Wall Mounted Enclosures, Floor Mounted Enclosures .....8-122
Overview and Features......................................................................8-69 Neutral Current Sensors and
ProTrip Trip Unit Conversion Kits Selection Guide.................8-70 POWER LEADER Accessories......................................................8-123
ProTrip Rating Plugs.............................................................................8-74 Draw-out Breaker Accessories.......................................................8-124
EntelliGuard TU Trip Unit Conversion Reference Publications............................................................8-126
Kits Selection Guide.............................................................................8-76
EntelliGuard TU Trip Rating Plugs..................................................8-80
EntelliGuard TU Trip Unit Conversion Kit
Accessories and Hardware ..............................................................8-81
Trip Unit Accessories..............................................................................8-83
Asbestos Free Arc Quencher Replacement Kits ...................8-85
Gerapid High Speed DC Circuit Breakers...............................8-86
Features and Benefits ...........................................................................8-86
Technical Data ..........................................................................................8-88
Outline Drawings and Dimensions..................................................8-89
Visit GE Industrial Solutions website for ordering low voltage power and insulated case circuit breakers and accessories at:
www.geindustrial.com/industrialsystems/wizards/peb_oem_am/home.htm
Standard Functions
The EntelliGuard G Circuit Breakers offer operational safety with
functions such as:
Closing and opening - can be initiated remotely or via the front
cover push buttons. An Open-Close-Open cycle is possible with-
out recharging.
Breaker/Main Contact Status - OPEN/CLOSED, ON/OFF indication
is provided on the front cover.
Through-Door Racking - The breaker racking mechanism is Two-Step Stored Energy Mechanism - Breaker operates via
accessible through the front door and permits safely disconnect- stored energy mechanisms that can be manually charged (MO) or
ing/withdrawing the circuit breaker without opening the door and electrically charged (EO) by the Spring Charging Motor. Closing
exposing personnel to live parts during the process. time is less than five cycles.
Ready to Close Indicator - Provides visible indication/readiness Reverse Feed EntelliGuard G devices can be fed from top or
for close operation. bottom terminals.
Breaker Status Indicators - Standard Indicators include: Coils - EntelliGuard G devices have provisions for four accessory
The breaker status indicator shows the condition of the main operating coils. The four positions can be filled by the following
contacts (OPEN, CLOSED). four devices: one Close Coil (CC or CCC), one Shunt Trip Coil, one
The status of the closing springs is indicated as CHARGED UVR (Under Voltage Release), and the fourth position can either
or DISCHARGED. be a Shunt Trip Coil or a UVR.
The draw-out position indicator displays whether the breaker is Motor Operator Heavy Duty, Motor/Gearbox Unit -
in the CONNECT, TEST or DISCONNECT position. easily accessible.
The breaker also includes a switch that provides main
contact status indication to the POWER LEADER Power Interlocks - Standard interlocks include:
Management System. Drawout Breaker
The optional Reduced Energy Let-Through (RELT) is provided Drawout Breaker/Main Contacts
with an ON/OFF contact closure to positively indicate whether Spring Discharge Interlock
the RELT setting is enabled or not. Padlocking Devices - The padlocking device is standard on
Rejection Feature - A factory-installed rejection feature prevents breakers and allows up to three padlocks with 1/4" to 3/8" diame-
mismatching breakers and cassettes/substructures. ter shanks to secure the breaker in the OPEN/TRIP FREE position.
Thermal Performance - ANSI C37 and UL 489 designs are 100%
rated up to 40C when applied in recommended enclosure sizes.
EntelliGuard G breakers are designed for flexibility and IEC 60947 versions are 100% rated in free air up to 50C. IP31
superiority with functions such as: enclosure/switchboard rating is based on size, recommended up
Short Time Rating - Up to 100kA for 0.5 sec. to 50C ambient with rear vertical bus connection.
Short Circuit/High Interruption Rating - 150kA at 600V, Field Installable Trip Units and Accessories Field - installable
100kA at 690V. accessories are common to all breaker envelopes and frames.
Optionally, accessories are also factory mountable.
Accessories
There are more than 20 different types of factory or field
installed accessories available for the EntelliGuard G circuit
breaker. Whether its a bell alarm contact, key interlock or
redundant shunt trips, GE has the accessory combinations to
meet your need!
Factory-Installed Accessories
Motor Operators
Closing Devices
Shunt Trip for Ground Fault
UVR with Fixed Time Delay
Second Shunt Trip or UV Release
Auxiliary Switches and Contacts
Bell Alarm and Trip Annunciation
Bell Alarm Contact
Trip Annunciation
Breaker Mounted Key Interlocks
Mechanical Interlocks- Fixed Breakers
Mechanical Interlocks Drawout Breakers
Accessories for Field Installation
Carriage Position Switch
Coil Signaling Contact Module
Contact Wear Indicator
Door Interlock
Electrical Close Switch
Lock Kits
Lifting Truck
Mechanical Operation Counter
Pushbutton Padlock Device
Ready-to-Close Switch
Secondary Disconnect Block
Spring Charged Contact
UVR Time Delay Module
Note: See page 8-15 for more information about the accessories
available for EntelliGuard G Circuit Breakers.
G A 1 6 M 1 H E R X 5 R A X X L 4 X 6 V
Digit 1 2 3, 4 5 6 7 8 9 10 11 12 13 14 15 16, 17 18 19 20 Digit
Circuit
Breaker Family Rating Plug
G = EntelliGuard G 1900
Breaker/Switch
Advanced Features and
Breaker Switch Type Communications
A = ANSI/U 1066 Monitoring + Data acq.,
Circuit Breaker Modbus Protocol + RELT
Notes: Override has 7% pick up tolerance. Nominal setting is 98% of lcw if no other instantaneous is on, or 107% of lcw if any other instantaneous is on. UL 489 CB always
have other instantaneous protection on. MCR set at 78% Close and Latch rating with a -10% tolerance. 6000A UL 489 CB is 100% rated as stationary and 80% rated
draw-out.
UL489B Ratings Suitable for use in Photovoltaic system in accordance with article 690 of the NEC
Rated Endurance
Minimum Minimum
Minimum Electrical Electrical
Short Interrupting Mechanical Endurance at Endurance at
Envelope Type Amps Current (kA) Endurance 600Vdc 1000Vdc
2 M 800-3000 30 12500 500 500
Four configurations available for 600Vdc and 1000Vdc with or without isolating both DC legs.
Note: Bus Bars must be ordered separately
Time Constant (L/R) = 15msec, Rated calibration temperature 50C.
Note: See EntelliGuard G Circuit Breaker Configurator for pricing. Contact a sales representative for configurator.
Digit 6 Mounting
Designation Mounting Poles Code
3 1
Drawout 4, right 2
4, left 3
OEM 3 4
Stationary 4, right 5
4, left 6
Drawout 3 D
GE Equipment
Stationary 3 F
NOTE: Right, Left indicates the location of the fourth pole, typically used to switch the Neutral.
NOTE: 800A Envelope 2 (E, M Ratings) are not available in 4-pole design.
NOTE: P frame available as 3-pole only
safety feature to ensure that the electrical closing signal must be released
before further closure is attempted, a shut off is initiated if the closing signal is
maintained.
NOTE: Manual button through breaker cover is included as standard assembly.
NOTE: When a Spring Charging Motor is selected (Digit 7), a Closing Device must be
selected from Closing Devices for Digit 8, and a Shunt Trip Device must be
selected from Shunt Trip 1 Devices for Digit 9.
SELECT ONE DEVICE ONLY.
Abbreviations
CCC = Command Operated Close Coil
CSC = Coil Signaling Contact
Hi-Fi = High Fidelity
PR = Power Rated
SD = Secondary Disconnect
NOTE: The term "Hi Fidelity" (HiFi) refers to gold-plated contacts used for signal level outputs (10mA minimum - 100mA maximum, 5-30Vdc, 125Vac)
NOTE: If no devices were selected in Digit 8, 9, 10, 11 (Codes = "X"), then Options A - V are Invalid
NOTE: Options A-V are only valid if the corresponding device to be monitored by the Coil Signaling Contact (CSC) is selected in digits 8, 9, 10, 11
3The 3NO/3NC scheme is STANDARD (INCLUDED, CODE 2) and is wired to Secondary Disconnect Block A; all other selections require Secondary Disconnect Block B
4For Side-mounted Secondary Disconnect Blocks All options are available EXCEPT options (4 and 8)
5In order to output the Coil Signaling status HiFi via trip unit (Options B, D, F, H, K, M, P, R, T, and V) a communications package must be selected in Advanced Features (Digit
19; options "2, 3, 6, 7, 8, 9") This options requires Secondary Disconnect Block B.
If a UL or ANSI Switch is selected in Digit 2 (C, D, M, S), the HiFi via Trip unit Options are not valid (Options B, D, F, H, K, M, P, R, T, and V)
Note: See EntelliGuard G Circuit Breaker Configurator for pricing. Contact a sales representative for configurator.
Digit 13 Bell Alarm, Mechanical Counter and Trip Annunciation Digit 15 Mechanical Interlocks
Bell Alarm, Mechanical Counter and Trip Annunciation Code Mechanical Interlocks Code
Bell Alarm Contact (1NO/1NC) with Lockout(BACL) A Black/None DEFAULT X
Mechanical Operations Counter(MOC) B Mechanical Interlock- Type A 1
Bell Alarm Contact (1NO/1NC) with Lockout and MOC C Mechanical Interlock- Type B 2
RTC Power Rated Contacts on SD1 1 Mechanical Interlock- Type C 3
RTC Signal Rated (HI-Fi) Contacts on SD1 2 Mechanical Interlock- Type D 4
RTC Signal Rated(HI-Fi) Contacts on SD1 3
RTC Signal Rated (HI-fi) Conatcts through Trip Unit2 D
Some installations use multiple power sources that are required to supply energy
BACL and RTC Power Rated Contacts on SD1 E simultaneously, alternately, or, in a specified sequence. EntelliGuard G Circuit
BACL and RTC Signal Rated (Hi-Fi) Contacts on SD1 F Breakers can be used to interconnect these sources and be electrically and
BACL and RTC Signal Rated (Hi-Fi) through Trip Unit 2 G mechanically interlocked to provide the necessary transition and protection.
BACL,MOC and RTC Power Rated on SD1 H Mechanical Interlocks are available for fixed and draw out circuit breakers.
BACL,MOC and RTC Signal Rated (Hi-Fi) through Trip Unit2 J The interlocks enable directly interlocking breakers that are mounted side by side
MOC and RTC Power Rated on SD1 K or in vertical stacks. The interlocks consist of two components: (1) The factory-
MOC and RTS Signal Rated on SD1 L
installed bracket fitted to the breaker (fixed breakers) or the cassette (drawout
MOC and RTC Signal Rated (Hi-Fi) through Trip Unit2 M
Blank/none X
breakers), and (2) The field-installable interconnecting cables available in lengths
of 1.0, 1.6, 2.0, 2.5, 3.0, 3.5 and 4.0m (ordered separately). Refer to Section 4 of the
Abbreviations Application Guide DET-653B for interlocking schemes.
BACL = Bell Alarm Contact with Lockout
RTC = Ready To Close Contacts Contact factory for availability.
Hi-Fi = High Fidelity
SD = Secondary Disconnect
1Ready To Close Switches are wired to where a Spring Charge Contact would be
2In order to output the RTC contact output via Trip Unit (options 3, F, J, M) a
communications package must be selected in Advanced Features
(Code 19/Step 16); this requires Secondary Disconnect Block B.
If a UL or ANSI Switch is selected, the (Hi-Fi Through Trip Unit) is not valid
(Options 3, F, J, M).
RTC Through the Trip Unit is not a valid option for Switches. Bell Alarm
Contact with Lockout comes with the Trip Unit set to Manual LO Enabled.
NOTE: The term Hi-Fi refers to gold-plated contacts used for signal level
outputs (10mA minimum - 100mA maximum, 5-30Vdc, 125Vac).
Bell Alarm Contact with Lockout comes with the Trip unit set to Manual LO Enabled
NOTE: This option provides factory installed interlocking devices for installation
between separate circuit breakers (baseplates and mechanism). This safeguard
ensures that a circuit breaker cannot be closed unless the dedicated key has been
inserted and secured within the lock.
NOTE: If selecting a Draw Out Breaker (Digit 6), consider putting the Key Interlock on
the Cassette versus the breaker. This enables the ability to swap breakers without
having to change the key interlocks.
Locks and Keys are NOT Supplied by GE.
Note: See EntelliGuard G Circuit Breaker Configurator for pricing. Contact a sales representative for configurator.
Note: See EntelliGuard G Circuit Breaker Configurator for pricing. Contact a sales representative for configurator.
The drawout mechanism allows the breaker to be racked in four distinct positions (CONNECTED, TEST, DISCONNECTED, WITHDRAWN).
Choice of whether shutters are needed are based in the order option 2nd disconnect Block B (GSDWCR).
G A 16 M 2 5
Digit 1 Digit 2 Digit 3,4 Digit 5 Digit 6 Digit 7
Digit 7 Shutters
Shutters with Locks Code
Shutter and Shutter Lock - Factory Installed S
None X
Shunt Trip
Power Nominal
Consumption Control Voltage Product Number
24Vdc GUVT024DR
DC: 350W, 30Vdc GUVT030DR
2W (sealed) 40Vdc; 48Vac/dc GUVT048R
60 - 72Vdc GUVT060DR
110Vdc/130Vdc; 120Vac GUVT120R
AC: 350W
208Vac GUVT208AR
(inrush),
220Vdc; 240Vac GUVT240R Under Voltage Release
20W (sealed)
250Vdc; 277Vac GUVT277R
1 NO
Voltage Amps Description Product Number
120Vac 6 High fidelity/secondary disconnect
AC GRTC2R
250Vac 6
125Vdc 0.5 Power rated/secondary disconnect GRTC1R
DC
250Vdc 0.25 High fidelity/trip unit GRTC3R
Auxiliary Switches
Auxiliary switches indicate breaker main contact position. They
change their state in the same time sequence as the breaker
main contacts.
Product
Description Number
Baseplate and mechanism for Kirk Key Key Interlock Facility
GBKRKR
Locks (Breaker Mounted)
Baseplate and mechanism for Ronis Locks GBRONR
(Breaker Mounted)
Mechanism for Ronis Key cassette interlock GCRONR
(Cassette mounted)
Mechanism for Kirk Key cassette interlock GCKRKR
(Cassette mounted)
Switch Product
Configuration Number
1 NO/NC switch per position GCPS1R
Set of 2 NO/NC switches per position GCPS2R
Set of 6 NO/NC switches connected position GCPS3R
Number of Product
Interlock Type Cables Required Breaker Type Poles Number
Withdrawable 3 GI2WADR
Withdrawable 4 GI3WADR
2 Way - Type A 2
Fixed 3 GI2FADR
Fixed 4 GI3FADR
Withdrawable 3 GI2WBR
Withdrawable 4 GI3WBR
1 from 2 - Type B 6
Fixed 3 GI2FBR
Fixed 4 GI3FBR
Withdrawable 3 GI2WCR
Withdrawable 4 GI3WCR
2 from 3 - Type C 6
Fixed 3 GI2FCR
Fixed 4 GI3FCR
Withdrawable 3 GI2WDTR
1 from 3 - Type D 4 Withdrawable 4 GI3WDTR
Fixed 3 GI2FDTR
Refer to Section 4 of the Application Guide DET-653B for interlocking schemes.
58
Current Product
Type Envelope Rating (A) Number
110
400 G04HNRCE
Remark: for ratings > 4000A two coils are used
600/630 G07HNRCE
800 G08HNRCE
1 1000 G10HNRCE Neutral Rogowski
1200/1250 G13HNRCE External
1600 G16HNRCE
2000 G20HNRCE
400 G04MNRCE
600/630 G07MNRCE
Encased with 800 G08MNRCE
Terminal Screws 1000 G10MNRCE
2 1200/1250 G13MNRCE
1600 G16MNRCE
2000 G20MNRCE
2500 G25MNRCE
3000/3200 G32MNRCE
3000/3200 (1600 x 2) G32LNRCE
4000 (2000 x 2) G40LNRCE
3
5000 (2500 x 2) G50LNRCE
6000/6400 (3200 x 2) G64LNRCE
400 G04HNRC
600/630 G07HNRC
800 G08HNRC
1 1000 G10HNRC
1200/1250 G13HNRC
1600 G16HNRC
2000 G20HNRC
400 G04MNRC
Loose Rogowski 600/630 G07MNRC
Coil and 800 G08MNRC
Mounting 1000 G10MNRC
Hardware 2 1200/1250 G13MNRC
1600 G16MNRC
2000 G20MNRC
2500 G25MNRC
3000/3200 G32MNRC
3000/3200 (1600 x 2) G32LNRC
4000 (2000 x 2) G40LNRC
3
5000 (2500 x 2) G50LNRC
6000/6400 (3200 x 2) G64LNRC
Product
Description Number
Door Escutcheon Kit - IP54 Door Panel - Fixed/ Drawout G54DR
Product
Description Number
Mechanical Operations Counter GMCNR
Product
Description Number
Door Interlock (Left Side) GLHD
Door Interlock (Right Side) GRHD
Product
Description Number
Env1 800 - 2000A, Type N&H, Flat Front UL489, GBB1TBF3
Fixed 3 Pole Breaker Bus Bar Terminations (Top/Bottom)
Env1 800 - 2000A, Type N&H, Flat Front UL489, GBB1TBF4
Fixed 4 Pole Breaker Bus Bar Terminations (Top/Bottom)
Env2 800A - 3000A Flat Front UL489 Fixed 3 Pole GBB2TBF3
Breaker Bus Bar Terminations (Top/Bottom)
Env2 800A - 3000A Flat Front UL489 Fixed 4 Pole GBB2TBF4
Breaker Bus Bar Terminations (Top/Bottom)
Env3 4000-6000A Flat Front UL Fixed 3 Pole GBB3TBF3
Breaker Bus Bar Terminations (Top/Bottom)
Env3 4000-6000A Flat Front UL Fixed 4 Pole
GBB3TBF4
Breaker Bus Bar Terminations (Top/Bottom)
Racking Handle
A collapsible Racking Handle is provided to rack in/out the draw
out breakers whenever needed.
Product
Description Number
Racking Handle GRHNR
Cluster Pad
Product
Envelope Size Description Number
1 Cluster Pad (set per phase) Qty 2 per GBB120TBD
Cluster Pad (single cluster) 2000A Qty 2 per GBB220TBD
2
Cluster Pad (double cluster) 2500A - 3200A Qty 2 per GBB232TBD
3 Cluster Pad Qty 2 per GBB360TBD
Product
Description Number
Fixed Breaker Top Mounted Secondary Disconnect, GSDFTR1
39 Pole Male/Female
Fixed Breaker Top Mounted Secondary Disconnect, GSDFTR2
78 Pole Male/Female
Fixed Breaker Side Mounted Secondary Disconnect, GSDFSR
78 Pole Male/Female
Remote Racker
The Remote Racking Operator allows the user to move a draw
out circuit breaker between the CONNECT and DISCONNECT posi-
tions via an electric racking gear head motor and the cassette
housing the breaker. The remote racking operator requires
115Vac, 60Hz control power. A control box connected
to the operator with a thirty-foot cord permits control from a
remote location.
Product
Description Number
Remote Racker EGGRRLV
Lifting Devices
Product
Poles Frame Number
3 1 and 2 GLD3F12
3 3 GLD3F3
4 1 and 2 GLD4F12
4 3 GLD4F3
ACB Lifting Truck ACBLIFT Frame 1 & 2,
For more accessories and options, see the EntelliGuard G Application Guide
3 Pole
DET-653B.
of each step, transfer the resulting product number digit(s) for WPS-16 1600 50 50 50
your selection to the appropriate boxes in the Product Number WPH-16 1600 65 65 65
Line. Helpful Hint: Make a photocopy of the Product Number Line WPS-20 2000 65 65 65
480
(page 8-29) every time you follow this process so you can use the (508)
WPS-32 3200 65 65 65
Note: See WavePro configurator for pricing. Contact a sales representative for configurator.
Example
Option or Accessory Option or Accessory
Tables A-1 to A-4 WPF-08 Breaker, 800A Frame Step 6 240V, 50/60 Hz electric lockout
Step 1 800A Class L Fuse, 800A Sensor Step 7 4-stage aux switch
Step 2 MVT PM Trip Unit with LSIG functions Step 8 Bell alarm with lockout
Step 3 700A Trip Unit Rating Plug Step 9 24V dc shunt trip (second shunt trip)
Step 4 120V ac 60Hz Electrical Charge & Close Operation Step 10 Hidden close push button and remote charge indicator
(Note: A disconnect comes standard with the options selected here.)
Step 5 120V ac shunt trip, 60 Hz
Step 1 Select Interrupting Type and Current Sensor (Example) GO TO STEP 2 ON PAGE 8-27
Current Sensor
Breaker Interrupting
Type Type & Rating No Sensor1 150A 400A 800A
WPS-08 Standard 1A 1B 1C 1D
WPH-08 High 2A 2B 2C 2D
WPX-08 Extended 3A 3B 3C 3D
300A Fuse AB AC AD
350A Fuse BB BC BD
400A Fuse CB CC CD
Class J
Fuse 450A Fuse DB DC DD
500A Fuse EB EC ED
WPF-08
600A Fuse FB FC FD
800A Fuse GB GC GD
1000A Fuse HB HC HD
Class L
Fuse 1200A Fuse JB JC JD
1600A Fuse KB KC KD
2 80
3 100
4 125 1
5 150 1, 2
6 200
7 225
8 250
9 300 1, 2
A 400
B 450 1, 2
C 500
D 600 1, 2
E 700
F 750 1, 2
G 800 1, 2
H 1000
J 1100 1, 2
K 1200
L 1500 1, 2
M 1600
N 2000
P 2400
Q 2500
R 3000
S 3200 1, 2
T 3600 1, 2
V 4000 1, 2
W 5000 1, 2
1At coordinate indicated, rating plug and current sensor combination available only on MicroVersaTrip trip units. Not available on Power+ trip units.
2At coordinate indicated, rating plug and current sensor combination available only on EntelliGuard TU trip units. Not available on Power+ trip units.
Step 4 Select Charge and Close Operators (Example) Step 9 Select Second Shunt Trip (Example)
Manual Charge, Electrical Charge
(not available with WPS-50 5000A breakers)
Manual Remote Close & Close
Product Product Product Voltage Product Number Digit
Number Number Number
Voltage Digit Digit Digit None X
Manual X 120V, 60Hz 1
120V, 60 Hz 1 F 240V, 60Hz 3
120V, 50 Hz 4 H 24Vdc B
120V, 50/60 Hz-48Vdc N 110/125Vdc E
240V, 60 Hz 3 T
240V, 50 Hz 6 W Step 10 Select Additional Options (Example)
48Vdc A E
A-Disconnect Hidden Close Operation Remote Charge Product No.
110Vdc B P PM Ready Push Button Counter Indicator Digit
125Vdc C Q X (none)
A
Step 5 Select Shunt Trip (Example) B
C
Voltage Product Number Digit D
None X E
120V, 60 Hz 1 F
208V, 60 Hz 2 G
240V, 60 Hz 3 H
70V, 60 Hz 4 J
120V, 50 Hz 5 K
208V, 50 Hz 6 L
M
Step 6 Select Undervoltage Trip OR Electric Lockout (Example) N
P
Undervoltage Undervoltage
(Instantaneous) with Time Delay Electric Lockout
Product Product Product Example only - ordering information starts on page 8-33.
Number Number Number
Voltage Digit Digit Digit Note: See WavePro configurator for pricing. Contact a sales
None X X X representative for configurator.
120V,
1 4
50/60 Hz
208V,
3
50/60 Hz
240V,
2 3 5
50/60 Hz
24Vdc A G
48Vdc B H
110Vdc C J
125Vdc C E J
Ordering Worksheet
The step-by-step process below allows you to systematically Follow the instructions at each step and transfer the product
arrive at the product number for your WavePro OEM breaker. As a number digit for each selection to the appropriate boxes in the
result, you will get exactly what you need. In addition, this system Product Number Line below. Note: You must submit a complete
reduces the cycle time, precisely specifies your requirements, 15-digit product number when ordering. If you reach a point
allows tracking during production and ensures accurate invoicing. where no further options or accessories are desired, fill in the
The final product number will appear on the breaker nameplate, remaining product number digits with X (for none).
so you can identify all components built into the original breaker For options not listed, contact your GE Sales Engineer or
and compare breakers within a facility for proper application. GE Switchgear Marketing for assistance.
Note: Photocopy this page for each breaker you select and
Date submit it with your order.
Name
Title
Company
Address
City
State
Zip
Telephone
Fax
Table A-1.
WavePro Interrupting Ratings (50/60 Hz ac)
Short-Circuit RMS Symmetrical kA
Rated AC Voltage,
Nominal (max) Breaker Type Frame Size (amps) Short-Time Withstand With Instantaneous Trip Without Instantaneous Trip
WPS-08 800 30 30 30
WPH-08 800 42 42 42
WPX-08 800 50 50 50
WPS-16 1600 42 42 42
WPH-16 1600 65 65 65
WPS-20 2000 65 65 65
600 WPS-32 3200 65 65 65
(635)
WPH-32 3200 85 85 85
WPX-32 3200 85 85 85
WPS-40 4000 85 85 85
WPX-40 4000 85 85 85
WPS-50 5000 85 85 85
WPX-50 5000 85 85 85
WPS-08 800 30 30 30
WPH-08 800 42 42 42
WPX-08 800 65 65 65
WPS-16 1600 50 50 50
WPH-16 1600 65 65 65
WPS-20 2000 65 65 65
480 WPS-32 3200 65 65 65
(508)
WPH-32 3200 85 85 85
WPX-32 3200 100 100 100
WPS-40 4000 85 85 85
WPX-40 4000 100 100 100
WPS-50 5000 85 85 85
WPX-50 5000 100 100 100
WPS-08 800 30 42 30
WPH-08 800 42 50 42
WPX-08 800 50 65 50
WPS-16 1600 50 65 50
WPH-16 1600 65 65 65
WPS-20 2000 65 65 65
240 WPS-32 3200 65 85 65
(254)
WPH-32 3200 85 130 85
WPX-32 3200 100 130 100
WPS-40 4000 85 130 85
WPX-40 4000 100 130 100
WPS-50 5000 85 130 85
WPX-50 5000 100 130 100
Table A-2.
Fused Breaker Ratings. Max. 600V ac 50/60 Hz.
Fuse Rating (Amps) 1
Interrupting Rating rms
Frame Size (Amps) Min Max Symmetrical kA Breaker Type
800 300 1600 200 WPF-08
1600 450 2500 200 WPF-16
2000 2000 2500 200 WPS-20 2
3200 2000 4000 200 WPS-32 2
4000 2000 5000 200 WPS-40 2
5000 2000 5000 200 WPS-50 2
1
The maximum fuse rating is the largest fuse that tests show will result in proper performance of the breaker and fuse in combination under short circuit conditions.
2
Fuses are mounted on separate fuse roll-out element and are ordered and shipped separately. See Table A-4 on page 8-31.
Table A-3.
Allowable Fuse Sizes for WavePro WPF and WPS breakers with separate fused rollout elements.
Note: WPS breakers with separate fuse roll-out element require the open fuse lockout (OFLO) device. Select OFLO only option for
breakers 2000A-5000A: The OFLO option is standard on WPF breakers.
Ferraz-Shawmut Fuse Range (Amps) 1
Darkened areas indicate available fuse ranges
Class J Class L
Breaker Frame
Type Size Sensor Rating Rating Plug 300 350 400 450 500 600 800 1000 1200 1600 2000 2500 3000 4000 5000
150A Below 150A
150A, 400A 150A
400A 225A
400A, 800A 300A
WPF-08 800A
400A, 800A 400A
800A 600A
800A 700A
800A 800A
800A 400A & below
800A 500A
800A, 1600A 600A
800A, 1600A 700A
WPF-163 1600A
800A, 1600A 800A
1600A 1000A
1600A 1200A
1600A3 1600A3
WPS-20 2 2000A 2000A 2000A & below
WPS-32 2 3200A 3200A 3200A & below
WPS-40 2 4000A 4000A 4000A & below
WPS-50 2 5000A 5000A 5000A & below
1 Class L fuses less than 800A are not UL or CSA listed. Use Class J fuses for 600A and below. 800A-2000A fuses are also available as welder limiters.
2 Fuses are mounted on separate fuse roll-out element and are ordered and shipped separately. See Table B-3 on pages 8-41 to 8-42.
3 Integrally fused 1600A frame breakers (WPF-16) equipped with 2500A fuses can be furnished with rating plugs from 300-1600A. Breakers equipped with
2500A fuses cannot be modified to accept lower rated fuses. WPF-16 breakers equipped with 2000A and lower fuses cannot be upgraded to 2500A fuses.
The maximum trip rating for a WPF-16 breaker is 1200A when furnished with other than 2500A fuses (see chart for min-max fuse rating for each rating
plug value). 2500A fuses preclude the use of shutters in the breaker cubicle.
Table A-4. Class L Fuses for Roll-out Elements on 2000A, 3200A, 4000A
Product Numbers for Replacement Fuses and 5000A Frames
Note: These product numbers are for field-installed replacement (replace original customer-installed fuses)
fuses. Original fuses for 800A and 1600A frame breakers are Fuse Rating Product Number
integral to the breaker and are factory installed. For larger frame 2000A A4BY2000-55BA
breakers (2000A and greater), customers must provide and sepa- 2500A A4BY2500-55BA
rately mount fuses. 3000A A4BY3000-55BA
Class J & Class L Breaker Mounted Fuses for 800A 4000A A4BY4000-55BA
5000A A4BY5000-55BA
and 1600A Frames
(replace original GE-installed fuses)
Fuse Class Fuse Rating Product Number Welder Limiters for Breaker Mounted Fuses
J 300A A4J300 (replace original GE-installed fuses)
J 400A A4J400
Fuse Rating Product Number
J 450A A4J450
J 500A A4J500 800A A4BX800
L 1000A A4BY1000BG
L 1200A A4BY1200BG
L 1600A A4BY1600BG
L 2000A A4BY2000
L (Silver) 2500A A4BQ2500GE
Selection
Before beginning the selection process, first determine the appropriate WavePro breaker type from Table A-1 on
page 8-30. You will need this information to proceed.
Breaker Type Interrupting Type & Rating No Sensor 1 150A 400A 800A
WPS-08 Standard 1A 1B 1C 1D
WPH-08 High 2A 2B 2C 2D
WPX-08 Extended 3A 3B 3C 3D
300A Fuse AB AC AD
350A Fuse BB BC BD
400A Fuse CB CC CD
Class J Fuse
450A Fuse DB DC DD
500A Fuse EB EC ED
600A Fuse FB FC FD
WPF-08 800A Fuse GB GC GD
1000A Fuse HB HC HD
Class L Fuse
1200A Fuse JB JC JD
1600A Fuse KB KC KD
800A Fuse ND
Welder Limiter
1600A Fuse QD
1 Draw-out breaker only, non-automatic.
Current Sensor
600A Fuse FF FG
800A Fuse GF GG
1000A Fuse HF HG
1200A Fuse JF JG
Class L Fuse
WPF-16 1600A Fuse KF KG
2000A Fuse LF LG
2500A Fuse MF MG
800A Fuse NF NG
Welder Limiter 1600A Fuse QF QG
2000A Fuse RF RG
1 Draw-out breaker only, non-automatic.
Step 1 (continued)
2000 Amp Frame 3200 Amp Frame
Breaker Interrupting No 2000A Breaker Interrupting No 3200A
Type Type Sensor 1 Sensor Type Type Sensor 1 Sensor
Standard 1H 1J Standard 1K 1L
WPS-20 WPS-32
OFLO only 2 4J OFLO only 2 4L
WPH-32 High 2K 2L
WPX-32 Extended 3K 3L
Step 2 (Cont.)
WavePro Catalog Number - Code 6
Function Long Short Non-Switchable Ground Product No.
Code Time Time Instantaneous Instantaneous Fault1 Digit
LSI P
LSIG Q
LSIGA 1
LSIGDA2 2
LSI2 U
LSIG2 7
LSIGA2 8
LSIGDA3 9
2Switchboard Applications
Defeatable Switchable
Function Long Short Instanta- Ground Ground ST or Inst ZSI-GF Product Product Product
Code Time Time neous Fault 1 Fault 1,3 & GF 1,3 ZSI-GF 4 & ST 4 No. Digits No. Digits No. Digits
LI AJ BJ CJ
LIG AK BK CK
LIGZ1 AL BL CL
LIGD3 AM BM CM
LIGDZ13 AN BN CN
LS AA BA CA
LSG AB BB CB
LSGZ1 AC BC CC
LSGZ2 AD BD CD
LSGD 3 AE BE CE
LSGDZ13 AF BF CF
LSGDZ23 AG BG CG
LSI AP BP CP
LSIG AQ BQ CQ
LSIGX 3 AR BR CR
LSIGZ1 AS BS CS
LSIGZ2 AT BT CT
LSIGD 3 AV BV CV
LSIGDZ13 AW BW CW
LSIGDZ23 AY BY CY
1 Ground fault is 3-wire/4-wire. If 4-wire ground fault is required, then one of the A-Disconnect options in Step 10 must be selected and the sensor for
the 4th wire (neutral) must be ordered separately. See Table B-5 on page 8-44.
3 Function combination is not UL Listed.
4 Requires zone selective interlock module, Type TIM1 (120Vac control voltage).
1At coordinate indicated, rating plug and current sensor combination available only on MicroVersaTrip trip units. Not available on Power+ trip units.
2At coordinate indicated, rating plug and current sensor combination available only on EntelliGuard TU trip units. Not available on Power+ trip units.
Manually Operated X
120V, 60 Hz 1 F
120V, 50 Hz 4 H
120V, 50/60 Hz - 48Vdc N
240V, 60 Hz 3 T
240V, 50 Hz 6 W
48Vdc A E
110Vdc B P
125Vdc C Q
250Vdc D R
1 Requires the selection of a shunt trip in Step 5 and a 4-stage or higher auxiliary switch in Step 7.
Table B-1.
Breaker Substructures
NOTE: Use shallow substructures unless there are other deep substructures
in the line-up.
Table B-2.
Fuse Rollout Elements and Substructures for Drawout Equipment Substructures
600 Volts AC, 50/60 Hz
NOTE: When used in conjunction with these fuse roll out elements, WavePro Type WPS
drawout circuit breaker elements should be equipped with an open fuse lockout (OFLO)
device, and the WPS breaker substructure should be ordered with a Keylock Mounting
Kit. Key interlock is supplied and mounted by the customer.
Table B-3
Breaker Substructures Accessories
Substructure accessories shown assembled are shipped separately for field installation.
Substructure Accessory
Product Number Accessory Product Number
Secondary Disconnect (bracket only) WPSDSFSH1
Secondary Disconnect (one 36-pin block) WPSDSUBM1
CT Hardware Mounting Kit, Metering Type (for 3 CTs) WPCTMTG1
CT Hardware Mounting Kit, Relaying Type (for 3 CTs) WPCTMTG2
WPS08SUBSH1 One-stage Position Switch Kit WPPSMTG1 Secondary disconnect blocks
WPH08SUBSH1
WPX08SUBSH1 Three-stage Position Switch Kit WPPSMTG2
Shutter Kit WPSHMTG1
Padlock Kit Standard on breaker
Keylock Mounting Kit (bracket only) WPSKLMTG1
Door Interlock Kit WPDIMTG1
Secondary Disconnect (bracket only) WPSDSFDP1
Secondary Disconnect (one 36-pin block) WPSDSUBM1
CT Hardware Mounting Kit, Metering Type (for 3 CTs) WPCTMTG1
CT Hardware Mounting Kit, Relaying Type (for 3CTs) WPCTMTG2
WPS08SUBDP1 One-stage Position Switch Kit WPPSMTG3
WPH08SUBDP1
WPX08SUBDP1 Three-stage Position Switch Kit WPPSMTG4
Shutter Kit WPSHMTG2
Padlock Kit Standard on breaker
Keylock Mounting Kit (bracket only) WPSKLMTG1
Door Interlock Kit WPDIMTG1
Secondary Disconnect (bracket only) WPSDSFDP1 Secondary disconnect bracket
Secondary Disconnect (one 36-pin block) WPSDSUBM1 with disconnects installed
CT Hardware Mounting Kit, Metering Type (for 3 CTs) WPCTMTG1
CT Hardware Mounting Kit, Relaying Type (for 3 CTs) WPCTMTG2
One-stage Position Switch Kit WPPSMTG5
WPF08SUBDP1
Three-stage Position Switch Kit WPPSMTG6
Shutter Kit WPSHMTG3
Padlock Kit Standard on breaker
Keylock Mounting Kit (bracket only) WPSKLMTG1
Door Interlock Kit WPDIMTG1
Substructure Accessory
Product Number Accessory Product Number
Secondary Disconnect (bracket only) WPSDSFSH1
Secondary Disconnect (one 36-pin block) WPSDSUBM1
CT Hardware Mounting Kit, Metering Type (for 3 CTs) WPCTMTG1
CT Hardware Mounting Kit, Relaying Type (for 3 CTs) WPCTMTG2
Table B-5.
Neutral Current Transformers (required with 4-wire ground fault).
Circuit Breaker Sensor Neutral Sensor
Frame (Amps) Amps Rating Rating (Amps) Product Number
150 100-300 TSVG303B
800
400, 800 300-800 TSVG508B
800 300-800 TSVG508B
1600
1600 600-1600 TSVG516B
2000 2000 800-2000 TSVG620B
3200 3200 1200-3200 TSVG832B
4000 4000 1600-4000 TSVG940B
Neutral Current Transformer
5000 5000 5000 TSVG950B
Table B-6.
Static Time Delays for Undervoltage Option
Voltage Static Time Delay Product No. 1
125Vdc TAKYUVT1
250Vdc TAKYUVT2
208 Vac (50/60 Hz) TAKYUVT5
240 Vac (50/60 Hz) TAKYUVT4
1
Must be ordered in conjunction with Undervoltage with Time Delay option in Step 6 on page 8-37.
Table B-7.
Miscellaneous Accessories
Static Time Delay
Accessory Product Number
Breaker Racking HandleStd 30" Long - Non Swivel 0324B4721G001
Breaker Racking Handle64" Long - Non Swivel 0324B4721G002
Breaker Racking Handle30" Long - Swivel Socket 0324B4724G001
Maintenance Closing Handle 568B386G1
Small Frame Lifting Assembly, WP08, 16, 20 0324B4551G001
Large Frame Lifting Assembly, WP32, 40 0247B8961G001
Extra Large Frame Lifting Assembly, WP50 0247B8961G003
Fuse Rollout Out Element Lifting Assembly, 3200A & 4000A 0247B8961G004
Fuse Rollout Element Lifting Assembly, 5000A 0247B8961G005
WavePro Breaker Maintenance Video (Approx. 40 minutes, VHS format) 2 DEV-042
2 Order only from Burlington OEM marketing.
Table B-9.
POWER LEADER Voltage Conditioner
Conditions and scales 120Vac to 1.76Vac for use by the trip unit for voltage sensing. Provides transient protection. Requires isolation
PTs with 120 volt secondary. Supports up to 15 trip units at a maximum distance of 20 feet. Required for PM trip units only.
System Requirements
Description Product Number (Not included with voltage conditioners)
Supplies isolated bus voltage signal PLVC1G01 One set of 3 voltage conditioners required
to EntelliGuard TU and MicroVersaTrip PM trip units. for each sensing location. PTs also required.
Table B-10.
The hand-held Portable Battery Pack provides an independent power source for EntelliGuard TU, microEntelliGuard, MicroVersaTrip
Plus and MicroVersaTrip PM trip units as an alternative to a test set. The battery pack is used to power up the trip unit to set or adjust
trip set points when the breaker is on the bench or otherwise not powered up. For microEntelliGuard trip units, the battery pack
connects to the trip unit through the 15-pin connector. A battery pack adapter cable is required. For MicroVersaTrip Plus and
MicroVersaTrip PM trip units, the battery pack connects to the trip unit through the rating plug test jack. The battery pack requires
three standard 9 Vdc alkaline batteries (not included).
Description Product Number
MicroVersaTrip Plus and PM Portable Power Pack TVPBP
EntelliGuard TU, microEntelliGuard Battery Pack Adapter Cable TVPBPACC
Table B-11.
MicroVersaTrip Rating Plug Removal Tool
Table B-12.
Portable Test Set
This portable, battery powered test kit provides self-tests and functional trip/no trip tests. It also provides defeat of the ground fault
function and be used in conjunction with high current test equipment. Interface is via a plug on the front of the trip units, and tests
can be conducted with the breaker in service. Test sets use either 120Vac power source or internal batteries (not included).
Portable Test Set - MicroVersaTrip Portable Test Set - EntelliGuard TU and microEntelliGuard
Table B-13.
Metering and Relaying Current Transformers for 800-5000A Substructures, 600 Vac, 50/60 Hz
Breaker Frame Size Ampere Ratio ():5 Metering Product Number Metering & Relaying Product Number
100 75C149640P001 75C149640P025
150 75C149640P002 75C149640P026
200 75C149640P003 75C149640P027
250 75C149640P004 75C149640P028
300 75C149640P005 75C149640P029
400 75C149640P006 75C149640P030
500 75C149640P007 75C149640P031
800A
1600A 600 75C149640P008 75C149640P032
2000A
800 75C149640P010 75C149640P034
1000 75C149640P011 75C149640P035
1200 75C149640P012 75C149640P036
1500 75C149640P013 75C149640P037
1600 75C149640P014 75C149640P038
2000 75C149640P015 75C149640P039
2500 75C149640P016 75C149640P040
2000 75C149640P020 75C149640P044
2500 75C149640P021 75C149640P045
3200A 3000 75C149640P022 75C149640P046
4000A
3200 75C149640P023 75C149640P047
4000 75C149640P024 75C149640P048
5000A 5000 75C149640P049 Consult Factory
OEM Benefits
Simplified OEM Modules (substructures)
Complete drawout DC breaker solution
Trolleys and Modules are UL recognized.
Outlines available in PDF and as AutoCAD templates for OEMs Drawout Trolley
All breaker controls prewired to secondary control disconnect
ANSI C37.20.1 and C37.14 required interlocking included
Accessories available, including various covers
and hardware kits
Substructures
Breaker Trolley
Description Product Number
Gerapid OEM Trolley-motor driven 700693
Gerapid OEM Trolley-manual drive 700694
Accessories
Description Product Number
Racking Handle 700695
Rear Side Cover 1500mm Depth Unit 700696
Rear Side Cover 1800mm Depth Unit 700697
Control Wireway Connector 700698
Control Wireway Cover 700699
Section Bolting Hardware Kit 289158
Cover Attachment Harware kit 289160
Door Hinges Kit 289709
To configure Gerapid OEM Modules and DC Circuit Breakers, visit our web\ wizard configuration tool at:
http://www.geindustrial.com/cwc/Dispatcher?REQUEST=PRODUCTS&id=gerapid&lang=en_US
Standard
Adjustable Long-Time (L) Pickup, 0.5 - 1.0X, with four delay bands.
Adjustable Instantaneous (I) Pickup, 1.5 - 15X.1
Options
Overload, Short Circuit, and Short-Time local trip indicators with
overload pickup warning and health monitor.
Adjustable Short-Time (S) Pickup, 1.5 - 9.0C, and delay (3 bands)
with I2t ON/OFF selection.
Adjustable Ground Fault (G) Pickup, 0.2 - 0.6S, and delay1
Power+ Trip Target Module (3 bands) with I2t ON/OFF selection and trip indicator.
Upgradeable Ground Fault function with use of appropriate
ground fault rating plug.
1Limited by breaker frame size above 2000A.
F O I L D P L W H TA
S
play also allows viewing of many standard metering parameters
R AB MV E TE EN TU
as well as pickup alarms, trip target indications and fault
6 9 AV R D E E Y S R I P
status information.
Enhanced MicroVersaTrip Plus and MicroVersaTrip PM trip
units continue to use GEs proven technique of measuring true
8- E TU S E T C T
rms currents (and voltages for MicroVersaTrip PM trip units) of
both sinusoidal and harmonically distorted waveforms. The fre-
E R C I L A A
quent sampling (64 times per cycle) allows precise calculations of Enhanced MicroVersaTrip Plus and MicroVersaTrip PM Trip
E T E. T .
LS EE P
Units have been specifically designed to integrate with the
G S A FA R Y S O E G R S
D L T D
true rms current. The sampling rate allows waveform measure-
ments up to the 31st harmonic to achieve accuracies of 99%. extensive capabilities offered by circuit breakers.
AI S RI
GEs true rms sensing avoids potential underprotection or over-
PA I T U O B L V E
protection problems associated with peak-sensing tripping systems.
The enhanced trip unit design includes a wide range of functions
and adds many new features:
N N T O N O
U A EN BE S I CR
.
UL Listed Field-Interchangeable Features exclusive to MicroVersaTrip PM Trip Units
Non-volatile trip targets display/Cold setup capability Communications
Replaceable long-life batteries provide trip target indications All information can be viewed on the LCD display or
I
RE N L I M
and cold setup capabilitywithout the need for external communicated over a POWER LEADER Power
power or a battery pack. Management System network.
E
Trip operations counter Demand/peak demand
:
The number of long-time, short-time, instantaneous and The trip unit can display a rolling average of power demand
W U E
T
ground fault trips are individually counted and displayed. and peak power demand at user-selected intervals from 5 to
I P OT
On overcurrent faults, the trip unit displays fault pickup, the Local and remote metering
type of fault, the magnitude of the fault current and the Amps, volts, frequency
TR N
Function Description 1 2 3 4 5 6 7 8 9 X A4 B4 C4 D4 E4
Metering
Communications Modbus Communications Bus Link
Amperes (A, kA)2 Selectable Phase Current 2.5%
Voltage (V) L-L or L-N Volts 1.5%
Energy (kWh, Mwh, GWh) Total Energy Usage on Brkr 4%
Real Power (kW/MW) L-L or L-N Power 4%
Total Power (kVA/MVA) L-L or L-N Power 4%
Frequency (Hz) Circuit Frequency 1Hz
Demand & Peak Demand (kW)
Relaying
Adjustable pickup, 50-90%
Under Voltage Trip
Adjustable delay, 1-15 seconds OFF
Adjustable pickup, 110-150%
Over Voltage Trip
Adjustable delay, 1-15 seconds OFF
Adjustable pickup, 10-50%
Voltage Unbalance
Adjustable delay, 1-15 seconds OFF
Adjustable pickup, 10-990kW
Current Unbalance Adjustable delay, 1-15 seconds Off
Power Reversal Direction
Data Acquisition - Waveform Capture
RELT
4Used when Ground Fault Alarm is needed via the output contact
800 1.5 thru 10.0 in 1.5 thru 15.0 in 0.20 thru 0.60 in
0.5 increments 0.5 increments increments of 0.01
1600 1.5 thru 10.0 in 1.5 thru 15.0 in 0.20 thru 0.60 in
0.5 increments 0.5 increments increments of 0.01
.44 at 200% of
2000 1.5 thru 10.0 in 1.5 thru 15.0 in 1.0 0.20 thru 0.60 in .10, .21, .35
pick-up at lower
0.5 increments 0.5 increments increments of 0.01
limit of band
3000 1.5 thru 10.0 in 1.5 thru 13.0 in 0.20 thru 0.37 in
0.5 increments 0.5 increments increments of 0.01
4000 1.5 thru 9.0 in 1.5 thru 9.0 in 0.20 thru 0.30 in
0.5 increments 0.5 increments increments of 0.01
2 Time delay shown at 600% of current setting at lower limit of band. X = Rating plug amps
3 Time delay shown at lower limit of each band. All pick-up tolerances are 10%. S = Sensor amp rating
4 Time delay shown at lower limit of each band. Ground fault pick-up not to exceed 1200 amperes. C = Long-time current setting (pick-up)
5 Time delay shown at 200% of pick-up at lower limit of band. H = Short-Time Rating
Additional Features and Characteristics Exclusive to the Enhanced MicroVersaTrip PM Trip Unit1
Trip Unit Suffix
Function Description M (Metering) P (Relaying) PM (Metering & Relaying)
G G M 1 6 L 4 X 6 A R X X X X
Digit 1 and 2 3 4 and 5 6 and 7 8 9 10 11 12 13 14 15
Trip Unit
Form
EntelliGuard
Frame Ratings
Advanced Features and Communications Manual / Auto Trip Reset (EntelliGuard G only)
Monitoring + Data Acquisition, Modbus Protocol + RELT Auto Reset/Reclose
NOTES:
All Advanced Feature selections require Secondary Disconnect Block B and
24Vdc control power
RELT = Reduced Energy Let Through
Monitoring = Advanced Metering
Data Acquisition = Waveform Capture and Harmonic Analysis
EntelliGuard TU Trip Unit for Power Break, WavePro, AK/AKR, Conversion Kit Breakers Product Number Structure
G B 2 1 6 L 4 X 6 X R X X X X
Digit 1 and 2 3 4 and 5 6 and 7 8 9 10 11 12 13 14 15
Trip Unit
Form
Power
Break II
Frame Ratings
1600 Amp Frame
NOTES: G = Ground Fault Protection (GFP, 3-wire or 4-wire, internal summing), Trip and Alarm
L = Long Time (L, I2T) + Fuse Settings (I4T) (Fuse settings are now standard on all D = Defeatable/Switchable Ground Fault, NOT UL Listed
EntelliGuard Trip Units) A = Ground Fault, Alarm only
S = Short Time (Switchable if Instantaneous (I) protection is enabled) GA = Ground Fault Alarm Only
I = Standard Range Adjustable Instantaneous, (IOC, 2x-15x) GDA = Ground Fault Trip and Ground Fault Alarm (all switchable, Not UL Listed)
ZSI, Short time and Ground Fault; user selectable Z Factory Installed (Original) F
ZSI, Instantaneous, Short Time, and Ground Fault; user selectable T Replacement (Field Installed) R
Blank/None X
All ZSI selections require a special harness (contact factory) and 24Vdc control power.
ZSI Instantaneous (T), Power Break can only be used as a Feeder (ZSI-I out)
EntelliGuard TU
GTP 1100 U 12 25
Trip Unit Type Rating
Largest Current Sensor Rating
GTP = Trip unit rating plug
01 = 150A 16 = 1600A
EntelliGuard TU Trip Unit
02 = 200A 20 = 2000A
03 = 225A 25 = 2500A
Rating Plug Ampere Rating
04 = 400A 30 = 3000A
0060 = 60A 1000 = 1000A
06 = 600A 32 = 3200A
0080 = 80A 1100 = 1100A
07 = 630A 40 = 4000A
0100 = 100A 1200 = 1200A
08 = 800A 50 = 5000A
0125 = 125A 1500 = 1500A
10 = 1000A 60 = 6000A
0150 = 150A 1600 = 1600A
12 = 1200A 64 = 6400A
0200 = 200A 1700 = 1700A
13 = 1250A
0225 = 225A 1800 = 1800A
0250 = 250A 1900 = 1900A
0300 = 300A 2000 = 2000A
0350 = 350A 2200 = 2200A Smallest Current Sensor Rating
0400 = 400A 2400 = 2400A 01 = 150A 16 = 1600A
0450 = 450A 2500 = 2500A 02 = 200A 20 = 2000A
0500 = 500A 3000 = 3000A 03 = 225A 25 = 2500A
0600 = 600A 3200 = 3200A 04 = 400A 30 = 3000A
0700 = 700A 3600 = 3600A 06 = 600A 32 = 3200A
0750 = 750A 4000 = 4000A 07 = 630A 40 = 4000A
0800 = 800A 5000 = 5000A 08 = 800A 50 = 5000A
0900 = 900A 6000 = 6000A 10 = 1000A 60 = 6000A
12 = 1200A 64 = 6400A
Trip Unit Type 13 = 1250A
U = Universal Trip Plug
D2 20 LSI T1 R1
Trip Unit Type and Rating Replacement or New
D2 = Power Break II Power+ Trip Unit: R = Replacement trip unit
2000 A sensor maximum (Blank) = New
D3 = Power Break II Power+ Trip Unit:
3000 A sensor maximum
D4 = Power Break II Power+ Trip Unit: Trip unit options
4000 A sensor maximum T1 = Target Module without ground fault target
T2 = Target Module with ground fault target
(Blank) = Factory Installed
Current Sensor Rating
02 = 200 A 20 = 2000 A
04 = 400 A 25 = 2500 A
08 = 800 A 30 = 3000 A Auxiliary functions
10 = 1000 A 40 = 4000 A LI = Long-time and Instantaneous
16 = 1600 A LSI = Long-time, Short-time, Instantaneous
1Device Product Number requires an extender R for field installable kit version only.
NOTE: This information is provided only for use interpreting product numbers. It cannot be used to build product numbers.
TR 10 C 800 GF
Trip Unit Type Rating Ground Fault Function
TR = Trip unit rating plug Blank = No ground fault
All Power+, MicroVersaTrip Plus, GF = Ground fault
and MicroVersaTrip PM
rating plugs
Rating Plug Ampere Rating
Current Sensor Rating 100 = 100 A 800 = 800 A
02 = 200 A 20 = 2000 A 150 = 150 A 1000 = 1000 A
04 = 400 A 25 = 2500 A 200 = 200 A 1100 = 1100 A
08 = 800 A 30 = 3000 A 225 = 225 A 1200 = 1200 A
10 = 1000 A 40 = 4000 A 250 = 250 A 1500 = 1500 A
16 = 1600 A 300 = 300 A 1600 = 1600 A
400 = 400 A 2000 = 2000 A
Trip Unit Type 450 = 450 A 2500 = 2500 A
C = Power+ trip unit rating plugs 500 = 500 A 3000 = 3000 A
600 = 600 A 3600 = 3600 A
700 = 700 A 4000 = 4000 A
Power+ Target Module Product Numbers
TARGET00 = Blank insert for Target Module
TARGET01 = Target Module without ground fault target
TARGET02 = Target Module with ground fault target
NOTE: This information is provided only for use interpreting product numbers. It cannot be used to build product numbers.
J 3 32 LSI T1 R
Step 1 Step 2 Step 3 Step 4 Step 5 Step 6
Power+ / WavePro
MicroVersaTrip Plus, MicroVersaTrip PM Trip Unit and Power Break II Product Number
B2 20 LSI GZ1 PM R1
Trip Unit Type and Rating
B2 = Power Break II Enhanced
MicroVersaTrip Plus or PM Trip Unit:
2000 A Sensor maximum Remanufactured
B3 = Power Break II Enhanced RM = Remanufactured Trip Unit
MicroVersaTrip Plus or PM Trip Unit: RX = Exchanged Trip Unit
3000 A Sensor maximum
B4 = Power Break II Enhanced
MicroVersaTrip Plus or PM Trip Unit:
Trip Unit Options
4000 A Sensor maximum
Options for MicroVersaTrip PM trip units only. Must select one:
P = Protective relays & communications
Current Sensor Rating M = Metering & communications
02 = 200 A 20 = 2000 A PM = Protective relays, metering, & communications
04 = 400 A 25 = 2500 A (Blank) = MicroVersaTrip Plus trip unit
08 = 800 A 30 = 3000 A
10 = 1000 A 40 = 4000 A
16 = 1600 A
Ground Fault Functions
G = Ground fault
Auxiliary Functions GD = Ground fault defeatable (not UL listed)
LI = Long-time and instantaneous GZ1 = Ground fault; zone selective interlocking for ground fault only
LSI = Long-time, short-time, instantaneous GZ2 = Ground fault and short-time selective interlock
LSH = Long-time, short-time, high-range GDZ2 = Ground fault defeatable (not UL listed): ground fault and
instantaneous short-time selective interlock
(Blank) = None
1Device Product Number requires an extender R for field installable kit version only.
NOTE: This information is provided only for use interpreting product numbers. It cannot be used to build product numbers.
TR 10 B 800
Device Type
Rating Plug Ampere Rating
TR = Trip unit rating plug
100 = 100 A 1000 = 1000 A
All MicroVersaTrip Plus and
150 = 150 A 1200 = 1200 A
MicroVersaTrip PM rating plugs
200 = 200 A 1500 = 1500 A
225 = 225 A 1600 = 1600 A
300 = 300 A 2000 = 2000 A
Current Sensor Rating
400 = 400 A 2500 = 2500 A
2 = 200 A 20 = 2000 A
500 = 500 A 3000 = 3000 A
4 = 400 A 25 = 2500 A
600 = 600 A 3600 = 3600 A
8 = 800 A 30 = 3000 A
700 = 700 A 4000 = 4000 A
10 = 1000 A 40 = 4000 A
800 = 800 A
16 = 1600 A
NOTE: This information is provided only for use interpreting product numbers. It cannot be used to build product numbers.
A 3 32 LSI G Z1 PM R
Step 1 Step 2 Step 3 Step 4 Step 5 Step 6 Step 7 Step 8
MicroVersaTrip Plus, MicroVersaTrip PM Trip Unit and Power Break Product Number
C 2 08 LSI G Z1 PM R
Step 1 Step 2 Step 3 Step 4 Step 5 Step 6 Step 7 Step 8
A 2 04 LSI G Z1 PM R
Step 1 Step 2 Step 3 Step 4 Step 5 Step 6 Step 7 Step 8
Step 3 Installed CT
Installed CT Code
150A 01 Step 7 Communication, Metering and Relaying
225A 03 Communication, Metering and Relaying Code
400A 04
600A 06 Relaying and Communication P
800A 08 Metering and Communication M
1600A 16
2000A 20
3000A 30
3200A 32 Step 8 Remanufactured
4000A 40 Remanufactured Code
Remanufactured trip unit RM
Exchanged trip unit RX
GE offers a complete line of trip unit upgrade kits for low voltage
power circuit breakers manufactured by GE, as well as by
Westinghouse, I-T-E, and Allis-Chalmers. These conversion kits
contain everything necessary to convert an old-style electro-
mechanical or solid-state trip unit to today's latest electronic,
digital technologyincluding the addition of metering, protective
relay, waveform capture, RELT, and communication functions.
All conversion kits designed by GE are tested to ANSI C37.59
standards for each breaker type so customers have the
assurance of safe, reliable operation.
Features and BenefitsAll Kits
Kit includes everything needed in one compact package
Full-range of interchangeable rating plugs
Trip targets for quick identification of overload, short circuit,
and ground fault trips
Sealable, see-through cover to prevent unauthorized access to
trip unit settings
Portable Trip Unit Test Kits; GTUTK20 and TVRMS2
Eliminate costly downtime due to nuisance tripping
Improved power system coordination and protection
Extend life and function of existing breakers and low voltage
equipment
AK-25 Breaker with EntelliGuard TU Trip Unit
EntelliGuard TU Conversion Kits
True RMS sensing with a sampling rate of 48 samples per cycle
with the ability to Waveform capture 4 cycles prior and 4 cycles
after an event
Long Time, Short Time, and Instantaneous Standard on all trip
units. S and I switchable on ANSI breakers
Large backlit LCD screen, view all currents on one screen
Trip settings and trip target information stored in non-volatile
memory
On-board lithium battery (field replaceable) for cold set-up and
reading trip targets
Status and Event Log, view the last 10 events
Health Status LED and Thermal Memory
Comm port for interface with set-up software and to download
Waveform
Optional metering, relaying, communications, ZSI - I, ground
fault (trip & alarm), and fused shaped curves
Plug and Play with previous generation of RMS9, EPIC, MVT and
Enhanced MVT Trip Units
ProTrip Conversion Kits EntelliGuard TU Conversion Kits
Cost-effective upgrade with standard adjustable long time,
short time, instantaneous, and defeatable ground fault functions Everything You Need in One Package
Simple-to-use rotary switches for selecting the trip unit pickup ProTrip and EntelliGuard TU conversion kits for the breakers
and delay settings listed in the following pages are shipped complete with detailed
True RMS sensing with sampling rate of 48 times per cycle installation instructions and everything needed for fast and easy
per phase - accurate waveform measurements through the trip unit conversions.
11th harmonic
Standard target module with individual LEDs for overload pick- Digital solid-state trip with quick disconnect
up, overload trip, short circuit trip, ground fault trip, and target Direct-acting flux shift trip actuator with automatic reset
module battery monitor Epoxy encapsulated high-accuracy current sensors
Interchangeable rating plug (order separately)
Specially designed mounting hardware and wire harnesses for
each breaker frame
6 9 AV R D E E Y S R I P
productivity and reduce costs, while meeting all your electrical
S
system monitoring needs.
R AB MV E TE EN TU
The POWER LEADER Modbus Concentrator can be connected to
MicroVersaTrip PM trip units, allowing communication with the
GE Power Management Control System (PMCS) software. With
F O I L D P L W H TA
PMCS, you'll see how easy it is to:
8- E TU S E T C T
View custom metering screens and CAD drawings of our system
E R C I L A A
Analyze energy consumption and power factor trends to mini-
E T E. T .
mize utility demand and PF charges or provide cost allocations
LS EE P
G S A FA R Y S O E G R S
D L T D
Collect precise sequence of event and alarm information to Refer to BuyLog Section 22 for additional Power
AI S RI
speed diagnosis and minimize downtime Management components not supplied with the
Utilize alarm and event logs to assist with maintenance interval MicroVersaTrip PM conversion kits
PA I T U O B L V E
.
cate with MicroVersaTrip PM trip units on Spectra Series
molded case circuit breakers, Power Break II insulated case cir-
TS IC
cuit breakers, and AKR/WavePro power circuit breakers (refer to Reference Publications
BuyLog Section 22 for network architecture) GE MVT Plus and PM Conversion Kits DET-066
I-T-E MVT Plus and PM Conversion Kits DET-067
RE N LL I M
Communicate with Modbus RTU-supported electronic meters Westinghouse MVT Plus and PM Conversion Kits DET-093
and relays Allis-Chalmers MVT Plus and PM Conversion Kits DET-226
E
GE ProTrip Conversion Kits DET-228
I-T-E ProTrip Conversion Kits DET-229
:
undervoltage
overvoltage
voltage unbalance
I
current unbalance
M
power reversal
power direction setup
Overview
GE is extending the lifecycle of this important component by
offering a remanufactured MVT solution. As of January 2012, GE
will no longer manufacture its MicroVersaTrip Plus and
MicroVersaTrip PM trip units.
GEs MVT Trip Units were manufactured from 1994 through 2011.
GEs latest Trip Unit model is the EntelliGuard TU, offering
improved selectivity and reliability. However, for those customers
not yet ready to upgrade, GE offers Remanufactured MVT Trip
Units to extend the lifecycle of this product for an additional 5 or
more years.
GE is committed to our customers through lifecycle support of
legacy equipment with quality services and solutions meeting
MicroVersaTrip Plus MicroVersaTrip PM
original specifications.
GE Remanufactured MVT Trip Units meet OEM specifications,
including new electronic boards and factory acceptance testing.
Key Features
Original GE parts
Complete replacement of all electronic circuit boards
Fully tested to original specifications
GE warranty
Standard next-day shipping; same-day shipping available
upon request
POWER LEADER communications network supported
Benefits
Longer life
GE Remanufactured MVT Trip Units allow you to extend the
lifecycle of your trip unit with service and remanufactured
products from GE.
Identical fit
GE Remanufactured MVT Trip Units are a plug-and-play unit
identical to your original unit in form, fit and function. Customers
are responsible for configuring the Remanufactured MVT Trip
Units to their specific system protection needs.
GE quality
GE Remanufactured MVT Trip Units have new electronic boards
and are fully tested to original manufacturers standards.
GE provides proven repair techniques and service from the
original manufacturer for your trip unit.
PK115 D 3 F 01 08
Breaker Trip Functions
AK-1-15 PK115 LSIGX- 08
AK-15 PKO151
AK-1-25 Trip Unit Functions
PK125 Sensor Rating
AK-25 LSIGX- Long Time, Short Time/INST.
PKO251 150A- 01
and Switchable Ground Fault (off)
AKU-25 225A- 02
AK-1-50 PK150 Not Approved for a UL Listed Breaker
600A- 06
AK-50
800A- 08
AKU-502
1600A- 16
AKT-50 PKO501 2000A- 20
AKS-50
3000A- 30
AKSU-502
4000A- 40
AKST-50
Sensor Rating Selection
AK-753 PKO753 Frame Breaker Product Numbers Sensors
AK-1003 PKO103
225 AK-1-15, AK-15 150A, 225A
Model 600 AK-1-25, AK-25, AKU-25 150A, 225A, 600A
Generation-D AK-1-50, AK-50, AKU-50,
1600 800A, 1600A
AKS-50, AKSU-50
Wiring 2000 AKT-50, AKST-50 2000A
3 Wire-3 3000 AK-75 3000A
4 Wire-4 4000 AK-100 4000A
Sensor Type
Fixed CTs-F
1
For converting AK-2 version breakers and newer, not applicable for AK-1 or AKR
2
Breakers equipped with older style open fuse lockout devices (OFLO), must be
retrofitted with newer style OFLO device prior to conversion process.
Order replacement OFLO kits as follows: AKU-50 - order OFLO kit #121C287OG2,
AK-75 - order OFLO kit #121C287OG3, AK-100 - order OFLO kit #121C287OG4
3
Contact the factory for stationary breaker applications
PIK22 D 3 F 02 08
Breaker Trip Functions
K225 PIK221 LSIGX- 08
K600
PIK601 Trip Unit Functions
KD0N600 Sensor Rating
K800 LSIGX- Long Time, Short Time/INST.
PIK801 150A- 01
and Switchable Ground Fault (off)
KD0N800 225A- 02
K1600 (black) Not Approved for a UL Listed Breaker
PIK1B1 400A- 04
KD0N1600 (black)
600A- 06
K1600 (red) PIK161,2
800A- 08
KD0N1600 (red) PIKN1,3
1600A- 16
Sensor Type
Fixed CTs-F
1
Applicable to breakers originally equipped with either electro-mechanical
trip devices or with solid state trip devices ("S" version breakers).
2
Only applicable to breakers originally equipped with rectangular shaped
primary disconnect assemblies.
3
Only applicable to breakers originally equipped with circular shaped
primary disconnect assemblies.
PSL6B D 3 F 02 08
Breaker Trip Functions
LA-600 (blue) LSIGX- 08
PSL6B
LAF-600 (blue)
LA-600 (gold) Trip Unit Functions
PSL6G Sensor Rating
LAF-600 (gold) LSIGX- Long Time, Short Time/INST.
150A- 01
LA-800 (gold) and Switchable Ground Fault (off)
PSL8O 225A- 02
LAF-800 (gold) Not Approved for a UL Listed Breaker
400A- 04
LA-1600 (blue)
PSL1B 600A- 06
LAF-1600 (blue)
800A- 08
LA-1600 (gold)
PSL1G 1600A- 16
LAF-1600 (gold)
Model
Sensor Rating Selection
Generation-D
Frame Breaker Product Numbers Sensors
Wiring LA-600 (blue), LAF-600 (blue)
600 150A, 225A, 600A
3 Wire-3 LA-600 (gold), LAF-600 (gold)
4 Wire-4 800 LA-800 (gold), LAF-800 (gold) 150A, 400A, 800A
LA-1600 (blue), LAF-1600 (blue)
1600 800A, 1600A
Sensor Type LA-1600 (gold), LAF-1600 (gold)
Fixed CTs-F
Conversion kits come standard with a rating plug that matches the current sensor. For rating plugs with different values, order separately. See page 8-74.
PDB15 D 3 F 02 08
Breaker Trip Functions
DB15, DBL15- PDB15 LSIGX- 08
DB25, DBL25- PDB25
Trip Unit Functions
DB50, DBL50- PDB50 Sensor Rating
LSIGX- Long Time, Short Time/INST.
DB75- PDB75 150A- 01
and Switchable Ground Fault (off)
DB100- PDB10 225A- 02
Not Approved for a UL Listed Breaker
600A- 06
Model
800A- 08
Generation-D
1600A- 16
3000A- 30
Wiring
4000A- 40
3 Wire-3
4 Wire-4
Sensor Rating Selection
Sensor Type Frame Breaker Product Numbers Sensors
Fixed CTs-F 225 DB15, DBL15 150A, 225A
600 DB25, DBL25 225A, 600A
1600 DB50, DBL50 800A,1600A
3000 DB75 3000A
4000 DB100 4000A
Conversion kits come standard with a rating plug that matches the current sensor. For rating plugs with different values, order separately. See page 8-74.
Reference Publications
ProTrip Trip Unit Conversion Kits for
GE Power Circuit Breakers - Fact Sheet DET-228
ProTrip Trip Unit Conversion Kits for
*Westinghouse Power Circuit Breakers - Fact Sheet DET-230
ProTrip Trip Unit Conversion Kits for
*Allis-Chalmers Power Circuit Breakers - Fact Sheet DET-231
ProTrip Trip Unit Conversion Kits for
*I-T-E Power Circuit Breakers - Fact Sheet DET-229 Rating Plug
Rating Plugs
Frame Size (Amps) Sensor Rating (Amps) Current Rating (Amps) Current Range (Amps) Product Number
225|600|800 150 80 40-88 PT1C80GFD
225|600|800 150 100 50-110 PT1C100GFD
225|600|800 150 125 63-138 PT1C125GFD
225|600|800 150 150 75-165 PT1C150GFD1
225|600|800 225 150 75-165 PT225C150GFD
225|600|800 225 225 113-248 PT225C225GFD1
600 600 300 150-330 PT6C300GFD
600 600 400 200-440 PT6C400GFD
600 600 450 225-495 PT6C450GFD
600 600 500 250-550 PT6C500GFD
600 600 600 300-660 PT6C600GFD1
800 400 200 100-220 PT4C200GFD
800 400 225 113-248 PT4C225GFD
800 400 250 125-275 PT4C250GFD
800 400 300 150-330 PT4C300GFD
800 400 400 200-440 PT4C400GFD1
800|1600 800 400 200-440 PT8C400GFD
800|1600 800 450 225-495 PT8C450GFD
800|1600 800 500 250-550 PT8C500GFD
800|1600 800 600 300-660 PT8C600GFD
800|1600 800 700 350-770 PT8C700GFD
800|1600 800 800 400-880 PT8C800GFD1
1600 1600 800 400-880 PT16C800GFD
1600 1600 1000 500-1100 PT16C1000GFD
1600 1600 1100 550-1210 PT16C1100GFD
1600 1600 1200 600-1320 PT16C1200GFD
1600 1600 1600 800-1760 PT16C1600GFD
2000 2000 1000 500-1100 PT20C1000GFD
2000 2000 1200 600-1320 PT20C1200GFD
2000 2000 1500 750-1650 PT20C1500GFD
2000 2000 1600 800-1760 PT20C1600GFD
2000 2000 2000 1000-2200 PT20C2000GFD
3000 3000 1200 600-1320 PT30C1200GFD
3000 3000 1600 800-1760 PT30C1600GFD
3000 3000 2000 1000-2200 PT30C2000GFD
3000 3000 2500 1250-2750 PT30C2500GFD
3000 3000 3000 1500-3300 PT30C3000GFD1
4000 4000 1600 800-1760 PT40C1600GFD
4000 4000 2000 1000-2200 PT40C2000GFD
4000 4000 2500 1250-2750 PT40C2500GFD
4000 4000 3000 1500-3300 PT40C3000GFD
4000 4000 3600 1800-3960 PT40C3600GFD
4000 4000 4000 2000-4000 PT40C4000GFD1
1Rating Plug furnished with conversion kit.
1Note: Long Time pickup range is 0.5-1.1 times the rating plug value. 1.1 setting allows the breaker to carry 100% of the rating plug current value, not to exceed the
continuous current (frame) rating of the breaker.
AKO25 C 3 F 06 04 A
Reference Publications 1For converting AK-2 version breakers and newer, not applicable for AK-1 or AKR.
2AKR30S Instantaneous Is Non-Switchable and the Non-Switchable High Range
EntelliGuard TU Conversion Kit Brochure DET-722
EntelliGuard TU Conversion Kit Supplemental Instructions DEH-3456 Instantaneous max is 22KA. LSH and LSHG Are Only Available on AKR30S.
EntelliGuard TU Trip Unit Installation/Instruction Manual DEH-4567 3Breakers equipped with older style open fuse lockout devices (OFLO), must be
EntelliGuard TU Test Set - GTUTK20 DEH-4568A retrofitted with newer style OFLO device prior to conversion process. Order
GE AK-1-15, AK-1-25 GEH-6466 replacement OFLO kits as follows: AKU-50 - order OFLO Kit #121C2870G2,
GE AK-1-50 DEH-40027 AK-75 - order OFLO kit #121C2870G3, AK-100 - order OFLO kit #121C2870G4.
GE AK-15, AK, AKU-25, AKR-30S, AKRU-30S GEH-5967 4Not applicable for converting breakers equipped with Power Sensor - contact
GE AKR-30,30H, AKRU-30, AKR-50, AKJ-50 Series GEH-5966
GE AK-100, AK,U,T,S,SU,ST-50, AK-75 GEH-5965
factory.
5Contact the factory for stationary breaker applications.
GE AKR-100, AKR-75, AKW-100 GEH-5964
6Only applicable to trip units with ground fault.
Westinghouse DB-15 GEH-6318
Westinghouse DB-25, DBL-25 (225A), DB-50, DBL-50 GEH-6319 7Available only for MicroVersaTrip RMS-9 type AKR breakers equipped with fixed
Westinghouse DS-206, DSL-206, DS416, DSL-416, DS-420, DS-632 DEH-023 current sensors.
Westinghouse DB-100 (4000A), DB-75 (3000A) GEH-6320 8Not available on AK-75 breaker frames.
ITE K-1600 (red), K, KDON-1600 Black, K-2000, K-225, K-600, 9Contact factory for availability.
KDON-600, K-800, KDON-800, KDON-1600 (red) GEH-6294 10Not applicable for slate version breakers.
ITE KC (1600A), KC (800A) GEH-6433 11Left pole accessories must be removed or relocated.
ITE KA GEH-6293
12Right pole accessories must be removed or relocated.
ITE KB (Metal), KB (Slate Drawout), KB (Slate Fixed) GEH-6295
131600-amp version of the KC breaker.
ITE K-3000, K-4000 DEH-133
ITE KD-3000, KE-4000 DEH-40019 14800-amp version of the KC breaker.
Allis Chalmers LA, LAF - 1600 (BLUE), LA, LAF-600 (BLUE) DEH-40008 15Order for red or black insulator as applicable.
Allis Chalmers LA, LAF - 1600 (GOLD), LA, LAF-600 (GOLD), LA, LAF-800, 16Not applicable to fixed mounted breakers.
RL, RLX, RLE-1600 & 800 DEH-40009A 17Only applicable for blue-gray color version breakers.
18Applicable to both A and B version breakers.
19Applicable to both nameplated versions of integral fused breakers
(i.e., LA-600F and LAF-600).
20Only applicable for gold color version breakers.
21800-amp version of the LA-50 breaker.
22Only applicable for the 1600-amp, 6-pole primary disconnect version of
the LA-50 breaker.
23Only applicable for 1600-amp, 12 pole primary disconnect version of the
LA-50 breaker.
24Requires 24Vdc control power.
25Existing Allis-Chalmers, I-T-E and Westinghouse bell alarms will not work
with EntelliGuard TU.
26Trip Unit will be mounted horizontally on breaker.
Note: Conversion Kit tables are located on pages 8-78
through 8-80.
225 AK115
AKO15
AK125
600
AKO25
AKR30
800
AKR3S
AK150
1600 AKO50
AKR50
AK150
2000 AKO50
AKR50
3000 AKO75
3200 AKR75
AKO10
4000 AKR10
AKW10
600 ASL6B
ASL6G
ASL80
800
ASR80
ASL1B
1600 ASL1G
ASR16
2000 ASR0
3000 ASL30
3200 ASR32
ASR40
4000 ASL4G
ASL4B
225 AIKA2
AIK22
AIKBM
AIKBS
600 AIKBX
AIK60
800 AIKC8
AIK80
AIKC1
AIK16
1600 AIK1B
AIKN1
2000 AIK20
3000 AIK30
4000 AIK40
EntelliGuard TU Trip Rating Plug Specifications 2WavePro and AKR only. EntelliGuard G min. trip plug is 150A.
May Be Used With Trip Plug
3PowerBreak only. EntelliGuard G min. trip plug is 150A.
Plug Minimum Maximum Sensor 4WavePro and AKR only. EntelliGuard G min. sensor is 400A.
Rating Rating Sensor Product Number
5PowerBreak only. EntelliGuard G min. sensor is 400A.
60 A2 150A4 150A4 GTP0060U0101 6IEC only sensor, UL equivalents are 600A.
80A2 150A4 150A5 GTP0080U0101 7For ITE and Allis Chalmers 4000A breakers.
100A3 150A4 225A5 GTP0100U0103
125A2 150A4 225A5 GTP0125U0103
150A 150A4 400A GTP0150U0104
200A 200A5 400A GTP0200U0204
225A 225A 600A GTP0225U0306
250A 400A 630A1 GTP0250U0407
300A 400A 800A GTP0300U0408
350A 400A 800A GTP0350U0408
400A 400A 1000A GTP0400U0410
450A 600A 1200A GTP0450U0612
500A 600A 1250A1 GTP0500U0613
600A 600A 1600A GTP0600U0616
700A 800A 1600A GTP0700U0816
750A 800A 2000A GTP0750U0820
800A 800A 2000A GTP0800U0820
900A 1000A 2000A GTP0900U1020
1000A 1000A 2500A GTP1000U1025
1100A 1200A 2500A GTP1100U1225
1200A 1200A 3200A GTP1200U1232
1500A 1600A 4000A GTP1500U1640
1600A 1600A 4000A GTP1600U1640
1900A 2000A 5000A GTP1900U2050
2000A 2000A 5000A GTP2000U2050
2200A 2500A 5000A GTP2200U2550
2400A 2500A 6400A6 GTP2400U2564
2500A 2500A 6400A6 GTP2500U2564
3000A 3000A 6400A6 GTP3000U3064
3200A 3200A 6400A6 GTP3200U3264
3600A 4000A 6400A6 GTP3600U4064
4000A 4000A 4000A6 GTP4000U40407
4000A 4000A 6400A6 GTP4000U 4064
5000A 5000A 6400A6 GTP5000U5064 *Westinghouse is a trademark of Westinghouse Electric Corporation.
6000A 6000A 6400A6 GTP6000U6064
Harness Kits and Hardware to add RELT (Reduced Energy Let Through)
Breakers Component Product Number Description
24V Power Supply PLPS4G01 Power Leader 1.5A power supply for up to 15 trip units
All RELT Switch Kit GTURSK Includes blue lighted RELT switch, lockable cover, contacts,
8 wire harness, warning labels (see picture above)
RELT Harness Kit GTURHB 4 wire RELT & Ground Fault Alarm harness kit. Used to add RELT
or Ground Fault Alarm to an existing MVT installation in combination with an
EntelliGuard TU. Harness comes with breaker and cubicle side, 8 feet of
wire, terminal block, and RELT labels. Includes 9 pin harness for 24VDC,
AK, AKR, Allis Chalmers,
communications, and voltage source.
ITE, Westinghouse
RELT Harness Kit GTURHA 4 wire RELT & Ground Fault Alarm harness kit. Used to add RELT or
Ground Fault Alarm to an existing MVT installation in combination with
an EntelliGuard TU. Harness comes with breaker and cubicle side, 8 feet
of wire, terminal block, and RELT labels1
WavePro - 800-2000A RELT Harness Kit GTURHWP1 6 wires (4 for RELT, 2 for 24VDC) from trip unit to secondary
disconnect block. Used to add RELT to an existing MVT Installation.
WavePro - 3200-4000A RELT Harness Kit GTURHWP2 6 wires (4 for RELT, 2 for 24VDC) from trip unit to secondary
disconnect block. Used to add RELT to an existing MVT Installation.
EntelliGuard TU Trip Units are compatible with MicroVersaTrip, RMS9, EPIC RMS9, MicroVersaTrip Plus and PM,
Enhanced MicroVersaTrip Plus and PM Trip Units models.
Now Available:
Power Break II in a Power Break I (fixed and drawout)
EntelliGuard R Retrofill (EntelliGuard G in AKD-5,
AKD-6, AKD-8 switchgear line-ups)
Contact factory for availability and options
AKO25 AQR1 G1
Breaker Model Application
AK-15 AQR1 Arc Quencher Replacement Kit For Asbestos Removal G1
AK-25 AKO25 1,2,3 Generation 1 Renewal Kit for G2
AKU-25 Ceramic Arc Quenchers
AKR-30S AKR3S 1,2
AKR-30
AKR30
AKRU-30
Arc Quenchers Replacement Kit
AKR-30H
AKR3H
AKRU-30H Product Number
AK-50 AKO25AQR1 G1
2,3
AKT-50 AKO50 AKR3SAQR1 G1
AKU-50 AKR30AQR1 G1
AKR30AQR1 G2
AKJ-50
AKR3HAQR1 G1
AKJT-50 AKR3HAQR1 G2
AKJU-50 AKR50 AKO50AQR1 G1
AKR-50 AKR50AQR1 G1
AKRT-50 AKR50AQR1 G2
AKRU-50 AKR5HAQR1 G1
AKR5HAQR1 G2
AKJ-50H
AKD50AQR1 G1
AKJT-50H AKD50AQR1 G2
AKJU-50H AKD5HAQR1 G1
AKR5H
AKR-50H AKD5HAQR1 G2
AKRT-50H AKO75AQR1 G1
AKR75AQR1 G1
AKRU-50H
AKO10AQR1 G1
AKJ-50 AKR10AQR1 G1
AKJT-50 AKD50 4
AKJU-50
AKJ-50H
AKJT-50H AKD5H 4
AKJU-50H
AK-75 AKO75 2,3
AKR-75 AKR75 2
AK-100 AKO10 2,3
AKR-100 AKR10 2
1Kits contain replacement barriers only, arc quenchers do not contain asbestos.
2G2 kits are not available for these breakers, please contact the factory for individual replacement arc quenchers.
3Does not apply to AK-1 series breakers.
4These kits are for use on breakers used in AKD and AKD-5 switchgear and substructures.
Electric utility Primary switchgear, 5kV-38kV Transformer Heavy duty traction rectifier DC switchgear
Third rail
or overhead
contact system
In addition to traction substation applications, Gerapid can be used as a feeder breaker in various other installations such as industrial
plants (metals industry), as field breakers for motor and generator field applications, and as disconnects for DC drives, to name a few.
General Information
Rated Temperature -5 to 40C ambient (55C with reduced ratings)
Relative Humidity 90% @ T<20C; RH=130-2*T @ T>20 C
Altitude -120m to 2000m above sea level
Control circuits
screw terminals and
Arc chute plug-in connectors
(1x2 shown, 1,000Vdc)
Instantaneous trip
mechanically operated,
adjustable (optional)
Technical Data for Feeder Circuit Breaker Models 2607 through 8007
Breaker type Gerapid 2607 Gerapid 4207 Gerapid 6007 Gerapid 8007
Arc chute type 1X2 1X4 2X2 2X3 2X4 1X2 1X4 2X2 2X3 2X4 1X2 1X4 2X2 2X3 2X4 1X2 2X2
Conventional thermal current Ith [A] (IEC/EN) 2600 4200 6000 8000
Rated voltage UNe [V] (EN 50123 / IEC 60947) 1000 2000 2000 3000 3600 1000 2000 2000 3000 3600 1000 2000 2000 3000 3600 1000 2000
Rated maximum voltage [V] (ANSI/IEEE C37.14) 800 N/A N/A N/A N/A 800 N/A 1600 N/A N/A N/A N/A N/A N/A N/A 800 N/A
Rated insulation voltage Ui [V] (EN 50123 / IEC 60947) 2000 2000 2000 3000 4000 2000 2000 2000 3000 4000 1000 2000 2000 3000 4000 1000 2000
Short time current 120 min [A] (EN 50123 / IEC 60947) 3150 5000 7200 9600
Short time current 2 min [A] (EN 50123 / IEC 60947) 5200 8500 12000 16000
Short time current 20 sec [A] (EN 50123 / IEC 60947) 7800 12600 18000 24000
Short circuit current according to IEEE C37.14 [kA] 120 120 60 120 *
Peak current according to IEEE C37.14 [kA] 200 200 100 200 *
Maximum arc voltage Uarc [kV] (EN 50123 / IEC 60947) 2 4 4 5.6 7 2 4 4 5.6 7 2 4 4 5.6 7 2 4
Weight ca. [kg] 120 120 160 160 160 120 120 160 160 160 150 150 165 165 165 190 210
Weight ca. [lbs] 265 265 352 352 352 265 265 352 352 352 331 331 364 364 364 419 463
Technical Data for Rectifier Circuit Breaker Models 8007R and 10007R
Parameter Reference Gerapid 8007R Gerapid 10007R
Arc chute type N/A 1x2 1x3 1x2 1x3
Rated continuous current [A] ANSI C37.14 p.5.3 6000 6000 8000 8000
2 hours current [A] N/A 7200 7200 9600 9600
2 minutes current [A] N/A 12000 12000 16000 16000
20 seconds current [A] N/A 18000 18000 24000 24000
Rated short-time current (250ms) [kA] ANSI C37.14 p.5.5 90 (149 peak) 60 (100 peak) 90 (149 peak) 60 (100 peak)
Rated maximum voltage [V] ANSI C37.14 p.5.2 800 1200 800 1200
Rated insulation voltage - UNm [V] EN 50124-1 p.1.3.2.4 2000 2000 2000 2000
Rated impulse voltage - UNi [kV] EN 50124-1 p.1.3.2.7 18 [12/50 s] 18 [12/50 s] 18 [12/50 s] 18 [12/50 s]
Power frequency voltage Ua [kV] EN 50124-1 a.B 2.2 10 [1 minute 50 Hz] 10 [1 minute 50 Hz] 10 [1 minute 50 Hz] 10 [1 minute 50 Hz]
Mechanical endurance [cycles] 1 N/A 10.000 10000 10000 10000
Rated short circuit peak / sustained current [kA] 2,3 ANSI C37.14 p.5.4 200 / 120 132 / 80 200 / 120 132 / 80
Short-circuit characteristic Tests a, b, c, d acc. ANSI C37.14 annex A High-speed High-speed High-speed High-speed
Maximum arc voltage [V] N/A 2500 2500 2500 2500
Mass ca. N/A 220 kG 220 kG 220 kG 220 kG
110000 cycles without parts replacement. Inspection after 5000 cycles. Max. 5000 cycles by means of ED impulse coil or POCT release.
2Tested for high and low frequency impedance bonds.
3Trip by means of POCT (direct-acting, instantaneous, electromechanical and polarized OC release) or by means of ED impulse coil with no intentional delay
To configure Gerapid OEM Modules and DC Circuit Breakers, visit our web\ wizard configuration tool at:
http://www.geindustrial.com/cwc/Dispatcher?REQUEST=PRODUCTS&id=gerapid&lang=en_US
Figure 1. Models 2607 - 6007 Feeder CBs, 1X4 Arc Chute, 2,000Vdc (Dimensions in mm)
Figure 2. Gerapid 8007 Feeder CBs, 1X4 Arc Chute, 2,000Vdc (Dimensions in mm)
Figure 3. Gerapid 8007R and 10007R Rectifier CB, 1X2 Arc Chute, 800Vdc
(Dimensions in mm)
1Molded case switch ratings are short time @ 600Vac, not interrupting current. See page 8-108 for withstand ratings.
Standard
Adjustable Long-Time (L) Pickup, 0.5 - 1.0X, with four delay bands.
Adjustable Instantaneous (I) Pickup, 1.5 - 15X.
Options
Overload, Short Circuit, and Short-Time local trip indicators with
overload pickup warning and health monitor.
Adjustable Short-Time (S) Pickup, 1.5 - 9.0C, and delay (3 bands)
with I2t ON/OFF selection.
Adjustable Ground Fault (G) Pickup, 0.2 - 0.6S, and delay1
Power+ Trip Target Module (3 bands) with I2t ON/OFF selection and trip indicator.
Upgradeable Ground Fault function with use of appropriate
ground fault rating plug.
1Limited by breaker frame size above 2000A.
6 9 AV R D E E Y S R I P
information and protective relaying, and allows integration with
S
GE POWER LEADER Power Management Systems. The trip unit
R AB MV E TE EN TU
display also allows viewing of many standard metering parame-
ters as well as pickup alarms, trip target indications and fault
status information.
F O I L D P L W H TA
Enhanced MicroVersaTrip Plus and MicroVersaTrip PM trip
8- E TU S E T C T
units continue to use GEs proven technique of measuring true
E R C I L A A
rms currents (and voltages for MicroVersaTrip PM trip units) of
E T E. T .
both sinusoidal and harmonically distorted waveforms. The fre-
LS EE P
G S A FA R Y S O E G R S
D L T D
quent sampling (64 times per cycle) allows precise calculations of Enhanced MicroVersaTrip Plus and MicroVersaTrip PM Trip
Units have been specifically designed to integrate with the
AI S RI
true rms current. The sampling rate allows waveform measure-
ments up to the 31st harmonic to achieve accuracies of 99%. extensive capabilities offered by Power Break II circuit breakers.
PA I T U O B L V E
GEs true rms sensing avoids potential underprotection or over-
protection problems associated with peak-sensing tripping systems.
The enhanced trip unit design includes a wide range of functions
N N T O N O
.
UL Listed Field-Interchangeable Features exclusive to MicroVersaTrip PM Trip Units
I
Replaceable long-life batteries provide trip target indications All information can be viewed on the LCD display or
and cold setup capabilitywithout the need for external communicated over a POWER LEADER Power
E
power or a battery pack. Management System network.
:
W U E
Demand/peak demand
The number of long-time, short-time, instantaneous and The trip unit can display a rolling average of power demand
I P OT
ground fault trips are individually counted and displayed. and peak power demand at user-selected intervals from 5 to
A
N
type of fault, the magnitude of the fault current and the Amps, volts, frequency
phase the fault occurred on. Real power, total power
Display indicates when a shunt trip or undervoltage release Accumulated energy
trip has opened the breaker. Protective relays include:
I
New status and setup displays for greater ease of use Power reversal direction setup
M
800 1.5 thru 10.0 in 1.5 thru 15.0 in 0.20 thru 0.60 in
0.5 increments 0.5 increments increments of 0.01
1600 1.5 thru 10.0 in 1.5 thru 15.0 in 0.20 thru 0.60 in
0.5 increments 0.5 increments increments of 0.01
.44 at 200% of
2000 1.5 thru 10.0 in 1.5 thru 15.0 in 1.0 0.20 thru 0.60 in .10, .21, .35
pick-up at lower
0.5 increments 0.5 increments increments of 0.01
limit of band
3000 1.5 thru 10.0 in 1.5 thru 13.0 in 0.20 thru 0.37 in
0.5 increments 0.5 increments increments of 0.01
4000 1.5 thru 9.0 in 1.5 thru 9.0 in 0.20 thru 0.30 in
0.5 increments 0.5 increments increments of 0.01
1 Time delay shown at 600% of current setting at lower limit of band. X = Rating plug amps
2 Time delay shown at lower limit of each band. All pick-up tolerances are 10%. S = Sensor amp rating
3 Time delay shown at lower limit of each band. Ground fault pick-up not to exceed 1200 amperes. C = Long-time current setting (pick-up)
4 Time delay shown at 200% of pick-up at lower limit of band. H = Short-Time Rating
Additional Features and Characteristics Exclusive to the Enhanced MicroVersaTrip PM Trip Unit1
Trip Unit Suffix
Function Description M (Metering) P (Relaying) PM (Metering & Relaying)
S S D 2 G 5 X 2 U 4 1 0 0 0 H
Step 1 Step 2 Step 3 Step 4 Step 5 Step 6 Step 7 Step 8 Step 9 Step 10 Step 11 Step 12 Step 13 Step 14 Step 15
POWER + X
Metering None
Communication None
Relays None
ZSI None
ENHANCED MVT X A B
ENHANCED MVT PM C D E F G H J K L
Metering Current Current Current Full Full Full Full Full Full
Communication COMNET COMNET COMNET COMNET COMNET COMNET COMNET COMNET COMNET
ENTELLIGUARD TU X A B C D E F G H J K L M N
Metering Current Current Current Current1 Full Full1 Full Full1 Current Current Current Current1
RELT None RELT RELT None1 RELT None1 RELT None1 None RELT RELT None1
Communication None None Modbus Modbus1 Modbus Modbus1 Modbus Modbus1 None None Modbus Modbus1
Relays None None None None1 None None1 YES YES1 None None None None1
ZSI None None None None1 None None1 None None1 GF&ST GF&ST GF&ST GF&ST1
ENTELLIGUARD TU P Q R V W Y Z 1 2 3 4 5 6 7 8 9
Metering Full Full1 Full Full1 Current1 Current1 Current1 Current1 Full1 Full1 Full1 Full1
RELT RELT None1 RELT None1 None1 RELT1 RELT1 None1 RELT1 None1 RELT1 None1
Communication Modbus Modbus1 Modbus Modbus1 None1 None1 Modbus1 Modbus1 Modbus1 Modbus1 Modbus1 Modbus1
Relays None None1 YES YES1 None1 None1 None1 None1 None1 None1 YES1 YES1
ZSI GF&ST GF&ST1 GF&ST GF&ST1 GFST&I1 GFST&I1 GFST&I1 GFST&I1 GFST&I1 GFST&I1 GFST&I1 GFST&I1
1 Zone Selective Intantaneous Ground Fault & Short Time & Instantaneous (out)
A 100
B 150 1
C 200
D 225
E 250
F 300 1
G 350 2 2 2 2 2 2 2 2 2
H 400 1
I 450
J 500
K 600 1
L 700
M 750 1
N 800 1
O 900 2 2 2 2 2 2 2 2 2
P 1000
Q 1100
R 1200 1
S 1250 2 2 2 2 2 2 2 2 2
T 1500
U 1600
V 1900 2 2 2 2 2 2 2 2 2
W 2000
Y 2200 2 2 2 2 2 2 2 2 2
Z 2400 2 2 2 2 2 2 2 2 2
1 2500
2 3000
3 3200 2 2 2 2 2 2 2 2 2
4 3600
5 4000
1Exclusive for MicroVersaTrip Plus and Enhanced MicroVersaTrip PM Trip Unit Rating Plugs
2Exclusive for EntelliGuard TU Trip Unit Rating Plugs only Step 11 Bell Alarm, Bell Alarm With Lockout, Kirk Key Provision
(Example)
Character 11 Bell Alarm Bell Alarm w/Lockout3 Kirk Key Provision4
Step 10 Shunt Trip (Example) 0 None None None
Character 10 Voltage With Lockout Without Lockout 1 None 240 None
0 None 2 None 600 None
1 12Vdc 4 240 None None
2 24Vac/24Vdc 5 240 240 None
3 48Vac/48Vdc 6 240 600 None
4 120Vac/125Vdc 8 600 None None
5 208Vac 9 600 240 None
6 240Vac/250Vdc A 600 600 None
7 480Vac G None None 4
8 600Vac H None 240 4
H 12Vdc J None 600 4
J 24Vac/24Vdc L 240 None 4
K 48Vac/48Vdc M 240 240 4
L 120Vac/125Vdc N 240 600 4
M 208Vac R 600 None 4
N 240Vac/250Vdc S 600 240 4
P 480Vac T 600 600 4
R 600Vac 3Bell Alarm ratings Vac
Step 12 UnderVoltage Release, Racking Padlock Step 13 Electric Operator, Push Button Cover, Hidden On
(Example) (Example)
Character 12 UnderVoltage Release Racking Padlock1 Character 13 Electric Operator Push Button Cover Hidden On
0 None None 0 None None None
1 24Vac None 1 120Vac None None
2 48Vac None 2 240Vac None None
3 120Vac None 3 24Vdc None None
4 208Vac None 4 48Vdc None None
5 240Vac None 5 72Vdc None None
6 480Vac None 6 125Vdc None None
7 600Vac None 8 None YES None
8 12Vdc None 9 120Vac YES None
9 24Vdc None A 240Vac YES None
A 48Vdc None B 24Vdc YES None
B 125Vdc None C 48Vdc YES None
C 250Vdc None D 72Vdc YES None
G None All E 125Vdc YES None
H 24Vac All G None None YES
J 48Vac All H 120Vac None YES
K 120Vac All J 240Vac None YES
L 208Vac All K 24Vdc None YES
M 240Vac All L 48Vdc None YES
N 480Vac All M 72Vdc None YES
P 600Vac All N 125Vdc None YES
R 12Vdc All R None YES YES
S 24Vdc All S 120Vac YES YES
T 48Vdc All T 240Vac YES YES
U 125Vdc All U 24Vdc YES YES
V 250Vdc All V 48Vdc YES YES
1Frame Rating W 72Vdc YES YES
X 125Vdc YES YES
Step 14 Closing Solenoid, Door Interlock, Counter Step 15 Auxiliary Switch, Stationary/Draw-out, Trimplate
(Example) (Example)
Character 14 Closing Solenoid Door Interlock Counter Character 15 Auxiliary Switch Stationary/Draw-out Trimplate
0 None None None 0 None Stationary None
1 120Vac None None 1 4-240V Stationary None
2 240Vac None None 2 8-240V Stationary None
3 24Vdc None None 3 12-240V Stationary None
4 48Vdc None None 4 4-600V Stationary None
5 72Vdc None None 5 8-600V Stationary None
6 125Vdc None None 8 None Stationary YES
8 None YES None 9 4-240V Stationary YES
9 120Vac YES None A 8-240V Stationary YES
A 240Vac YES None B 12-240V Stationary YES
B 24Vdc YES None C 4-600V Stationary YES
C 48Vdc YES None D 8-600V Stationary YES
D 72Vdc YES None H 4-240V Drawout None
E 125Vdc YES None J 8-240V Drawout None
G None None YES K 12-240V Drawout None
H 120Vac None YES L 4-600V Drawout None
J 240Vac None YES M 8-600V Drawout None
K 24Vdc None YES S 4-240V Drawout YES
L 48Vdc None YES T 8-240V Drawout YES
M 72Vdc None YES U 12-240V Drawout YES
N 125Vdc None YES V 4-600V Drawout YES
R None YES YES W 8-600V Drawout YES
S 120Vac YES YES
T 240Vac YES YES
U 24Vdc YES YES
V 48Vdc YES YES
W 72Vdc YES YES
X 125Vdc YES YES
S S D 08 * 02 H1
Power Break II Breaker Type
1High-range instantaneous sensors only available on MicroVersaTrip Plus and MicroVersaTrip PM units.
NOTE: This information is provided only for use interpreting product numbers. It cannot be used to build product numbers.
SP AS 240 AB4D R
Power Break II Breaker Extender
R = Field installable kit
Device Type
Blank = Factory installed
AS = Auxiliary switch2
BAA = Bell alarm, alarm only2 Auxiliary Switch Extender
BAL = Bell alarm with lockout2 AB4 = Auxiliary switch, type AB with 4 elements
COUNTER = Mechanical counter2 AB8 = Auxiliary switch, type AB with 8 elements
DIL = Defeatable door interlock AB12 = Auxiliary switch, type AB with 12 elements
DOSD = Drawout secondary disconnects (add suffix D for Drawout construction)
DOWB = Drawout mechanical interlock
DSS = Substructure shutter kit
E = Electric operator2 Voltage, unless otherwise stated
HDOS = Hi-Break rated drawout substructure 012 = 12 Vdc
K4 = Kirk key lock (4 maximum)2 024 = 24 Vdc
PBCOVER = Pushbutton cover2 048 = 48 Vdc
RCS = Remote close solenoid2 120/125 = 120 Vac or 125 Vdc
SDOD = Standard rated drawout substructure 240/250 = 240 Vac and 250 Vdc
ST = Shunt trip2 250 = 250 Vdc
STL = Shunt trip with lockout2 480 = 480 Vac
UV = Undervoltage release 600 = 600 Vac
WB = Walking beam for stationery breakers 08 = 800 A 25 = 2500 A
08 = 800A T-stud 16 = 1600 A 30 = 3000 A
20 = 1600 thru 2000A T-stud 20 = 2000 A 40 = 4000 A
S20 = 2000A T-stud (3000 frame) BCA = Back connected aluminum
S25 = 2500A T-stud BCC = Back connected copper
S30 = 3000A T-stud FCA = Front connected aluminum terminal T-stud
S40 = 4000A T-stud FCA = Front connected copper terminal T-stud
RAILS = Rail kit LFCC = Front connected copper, long stud
LUGA = Lug adapter kit 36B = 36 secondary disconnects, breaker
B = Enclosure 36C = 36 secondary disconnects, substructure
2Device Product Number requires an extender R for field installable kit version only.
NOTE: This information is provided only for use interpreting product numbers. It cannot be used to build product numbers.
G B 2 0 4 L 5 C 5 X R X X X X
Step 1 Step 2 Step 3 Step 4 Step 5 Step 6 Step 7 Step 8 Reserved Reserved Reserved Reserved
Trip Unit
Form Reserved
Power
Break II
GTP 1100 U 12 25
Trip Unit Type Rating Largest Current Sensor Rating
GTP = Trip unit rating plug 01 = 150 A 16 = 1600 A
EntelliGuard TU Trip Unit 02 = 200 A 20 = 2000 A
03 = 225 A 25 = 2500 A
Rating Plug Ampere Rating
04 = 400 A 30 = 3000 A
0060 = 60 A 1000 = 1000 A
06 = 600 A 32 = 3200 A
0080 = 80 A 1100 = 1100 A
07 = 630 A 40 = 4000 A
0100 = 100 A 1200 = 1200 A
08 = 800 A 50 = 5000 A
0125 = 125 A 1500 = 1500 A
10 = 1000 A 60 = 6000 A
0150 = 150 A 1600 = 1600 A
12 = 1200 A 64 = 6400 A
0200 = 200 A 1700 = 1700 A
13 = 1250 A
0225 = 225 A 1800 = 1800 A
0250 = 250 A 1900 = 1900 A Smallest Current Sensor Rating
0300 = 300 A 2000 = 2000 A 01 = 150 A 16 = 1600 A
0350 = 350 A 2200 = 2200 A 02 = 200 A 20 = 2000 A
0400 = 400 A 2400 = 2400 A 03 = 225 A 25 = 2500 A
0450 = 450 A 2500 = 2500 A 04 = 400 A 30 = 3000 A
0500 = 500 A 3000 = 3000 A 06 = 600 A 32 = 3200 A
0600 = 600 A 3200 = 3200 A 07 = 630 A 40 = 4000 A
0700 = 700 A 3600 = 3600 A 08 = 800 A 50 = 5000 A
0750 = 750 A 4000 = 4000 A 10 = 1000 A 60 = 6000 A
0800 = 800 A 5000 = 5000 A 12 = 1200 A 64 = 6400 A
0900 = 900 A 6000 = 6000 A 13 = 1250 A
Trip Unit Type
U = Universal Trip Plug
D2 20 LSI T1 R1
Trip Unit Type and Rating Replacement or New
D2 = Power Break II Power+ Trip Unit: R = Replacement trip unit
2000 A sensor maximum (Blank) = New
D3 = Power Break II Power+ Trip Unit:
3000 A sensor maximum
D4 = Power Break II Power+ Trip Unit: Trip unit options
4000 A sensor maximum T1 = Target Module without ground fault target
T2 = Target Module with ground fault target
(Blank) = Factory Installed
Current Sensor Rating
02 = 200 A 20 = 2000 A
04 = 400 A 25 = 2500 A
08 = 800 A 30 = 3000 A Auxiliary functions
10 = 1000 A 40 = 4000 A LI = Long-time and Instantaneous
16 = 1600 A LSI = Long-time, Short-time, Instantaneous
1Device Product Number requires an extender R for field installable kit version only.
NOTE: This information is provided only for use interpreting product numbers. It cannot be used to build product numbers.
TR 10 C 800 GF
Trip Unit Type Rating Ground Fault Function
TR = Trip unit rating plug Blank = No ground fault
All Power+, MicroVersaTrip Plus, GF = Ground fault
and MicroVersaTrip PM
rating plugs
Rating Plug Ampere Rating
Current Sensor Rating 100 = 100 A 800 = 800 A
02 = 200 A 20 = 2000 A 150 = 150 A 1000 = 1000 A
04 = 400 A 25 = 2500 A 200 = 200 A 1100 = 1100 A
08 = 800 A 30 = 3000 A 225 = 225 A 1200 = 1200 A
10 = 1000 A 40 = 4000 A 250 = 250 A 1500 = 1500 A
16 = 1600 A 300 = 300 A 1600 = 1600 A
400 = 400 A 2000 = 2000 A
Trip Unit Type 450 = 450 A 2500 = 2500 A
C = Power+ trip unit rating plugs 500 = 500 A 3000 = 3000 A
600 = 600 A 3600 = 3600 A
700 = 700 A 4000 = 4000 A
Power+ Target Module Product Numbers
TARGET00 = Blank insert for Target Module
TARGET01 = Target Module without ground fault target
TARGET02 = Target Module with ground fault target
NOTE: This information is provided only for use interpreting product numbers. It cannot be used to build product numbers.
B2 20 LSI GZ1 PM R1
Trip Unit Type and Rating
B2 = Power Break II Enhanced
MicroVersaTrip Plus or PM Trip Unit:
2000 A Sensor maximum Remanufactured
B3 = Power Break II Enhanced RM = Remanufactured Trip Unit
MicroVersaTrip Plus or PM Trip Unit: RX = Exchanged Trip Unit
3000 A Sensor maximum
B4 = Power Break II Enhanced
MicroVersaTrip Plus or PM Trip Unit:
Trip Unit Options
4000 A Sensor maximum
Options for MicroVersaTrip PM trip units only. Must select one:
P = Protective relays & communications
Current Sensor Rating M = Metering & communications
02 = 200 A 20 = 2000 A PM = Protective relays, metering, & communications
04 = 400 A 25 = 2500 A (Blank) = MicroVersaTrip Plus trip unit
08 = 800 A 30 = 3000 A
10 = 1000 A 40 = 4000 A
16 = 1600 A
Ground Fault Functions
G = Ground fault
Auxiliary Functions GD = Ground fault defeatable (not UL listed)
LI = Long-time and instantaneous GZ1 = Ground fault; zone selective interlocking for ground fault only
LSI = Long-time, short-time, instantaneous GZ2 = Ground fault and short-time selective interlock
LSH = Long-time, short-time, high-range GDZ2 = Ground fault defeatable (not UL listed): ground fault and
instantaneous short-time selective interlock
(Blank) = None
1Device Product Number requires an extender R for field installable kit version only.
NOTE: This information is provided only for use interpreting product numbers. It cannot be used to build product numbers.
TR 10 B 800
Device Type
Rating Plug Ampere Rating
TR = Trip unit rating plug
100 = 100 A 1000 = 1000 A
All MicroVersaTrip Plus and
150 = 150 A 1200 = 1200 A
MicroVersaTrip PM rating plugs
200 = 200 A 1500 = 1500 A
225 = 225 A 1600 = 1600 A
300 = 300 A 2000 = 2000 A
Current Sensor Rating
400 = 400 A 2500 = 2500 A
2 = 200 A 20 = 2000 A
500 = 500 A 3000 = 3000 A
4 = 400 A 25 = 2500 A
600 = 600 A 3600 = 3600 A
8 = 800 A 30 = 3000 A
700 = 700 A 4000 = 4000 A
10 = 1000 A 40 = 4000 A
800 = 800 A
16 = 1600 A
NOTE: This information is provided only for use interpreting product numbers. It cannot be used to build product numbers.
The interruption ratings and voltages shown in the table are max-
imum ratings. A circuit breaker of the type given in the left-hand
column may be applied at the given circuit voltage in any electri-
cal distribution system where the available fault current at the
load terminals of the breaker does not exceed the value in the
table. That circuit breaker type may also be applied at intermedi-
ate values of circuit voltage provided the available fault current at
the load terminals of the breaker does not exceed the value in the
table for the higher value of voltage.
How To Order
Power Break IIs were previously ordered as separate product
numbers for the Frame, Trip Unit, Accessories, etc. In 2008, they
transitioned to a single 15 digit product number.
1. Determine your 15 digit number by using the BuyLog or the
digitized configurator.
2. Check Elitenet for price and availability. Note: Because the
number of possible combinations is in the millions, only product
numbers that have been ordered are in EliteNet. If the number
is not available in Elitenet, email the request to load the part to
GE.1STOP_REPLY@GE.com
3. Once the product number is loaded and pricing finalized, the
product can be ordered.
4. Note: Substructures/Cassettes, Neutral CTs, T-Studs, Drawout
Secondary disconnects are ordered separately from the 15 SSF20B220 Frame
digit number.
Draw-out in Substructure
ExampleDraw-out Breaker SHD2B4X6K200130
1600 ampere draw-out frame, 100 kA, 480 V IC rating, 1000 ampere
sensor, 600 ampere rating plug, trip unit functions including long-
time (L), short-time (S), high range instantaneous (H), factory installed
accessories including: 120 Vac electric (motor) operator; 24 Vdc
remote close solenoid; 24 Vdc shunt trip; draw-out substructure;
draw-out secondary disconnect; draw-out shutter.
R RE A NU E O II
Basic Frame SelectionStationary
PR K M N
FO B T R K
IN I R
Standard Break Hi-Break
Circuit Breaker Circuit Breaker
Envelope Size Frame Size Current Sensor Product Product
IC I BE
(Amperes) (Amperes) (Amperes) Number1 Number1
R E R U C AT U E A
200 SSF08*202,H SHF08*202,H
800 800 400 SSF08*204,H SHF08*204,H
800 SSF08*208,H SHF08*208,H
TO W O D C L B R
800 SSF16*208,H SHF16*208,H
.
G
1600 1600 1000 SSF16*210,H SHF16*210,H
1600 SSF16*216,H SHF16*216,H
U P P E R
1000
SSB25*210,H SHB25*210,H
FI SE O O W
SSF25*220,H SHF25*220,H
2500 2000
RA O R N
SSB25*220,H SHB25*220,H
3000
PO
SSF25*325,H SHF25*325,H
2500
SSB25*325,H SHB25*325,H
SSF30*330,H SHF30*330,H
3000 3000
SSB30*330,H SHB30*330,H
CO N 9 ED EE
F
T
3000
N
How to Order 5. For replacement trip units, add suffix R. Check Elitenet for
1. Determine the basic trip unit product number. List Price and GO schedule.
Example:
2. Determine the type of trip unit, EntelliGuard TU , Power+,
1600 Ampere frame, 1000 ampere sensor, Long-time (L). Short-time
MicroVersaTrip Plus or MicroVersaTrip PM trip unit.
(S), Instantaneous (I), MicroVersaTrip PM with metering only.
3. Select the trip unit suffix representing the protection function to Order B210LSIM. The replacement trip unit product number
complete trip unit product number. would be B210LSIMR.
4. Order rating plug separately.
9
Trip Unit Trip Selectable Long-Time Short-Time Inst. High Inst. Ground Fault GF Zone GF/ST Zone
9
ER
Suffix1 Indicators Phase Ammeter (L) (ST) (I) (H) (G) 2 Interlock (Z1) 3 Interlock (Z2) 3
R . TA P P O . 8 -
Adjustable Instantaneous
TO E N O R E E G I
LIM
RA S F S P I
R .
W
FO G
G PR O N O K
LIGM
LIGZ1M
N
LSIM
I
F I E AT A E A
LSIGM
VE C
LSIGZ1M
N S R UR ER UR BRE
U E R D N
LSIGZ2M
I
TI R
Fixed High Range Instantaneous 4
LSHM
LSHGM
LSHGZ1M
LSHGZ2M
FI M L A ER
O N N W
Trip Unit Trip Selectable Long-Time Short-Time Inst. High Inst. Ground Fault GF Zone GF/ST Zone
Suffix 1 Indicators Phase Ammeter (L) (ST) (I) (H) (G) 2 Interlock (Z1) 3 Interlock (Z2) 3
Adjustable Instantaneous
SA N U C
LIP
TA I I U M E
LIGP
N K D NO SE
LIGZ1P
LSIP
LSIGP
CO E A R O ED TE:
LSIGZ1P
LSIGZ2P
Fixed High Range Instantaneous 4
BR R A NO
LSHP
LSHGP
LSHGZ1P
LSHGZ2P
L
T
Trip Unit Trip Selectable Long-Time Short-Time Inst. High Inst. Ground Fault GF Zone GF/ST Zone
Suffix1 Indicators Phase Ammeter (L) (ST) (I) (H) (G) 2 Interlock (Z1) 3 Interlock (Z2) 3
P
Adjustable Instantaneous
U
LIPM
LIGPM
LIGZ1PM
LSIPM
LSIGPM
LSIGZ1PM
LSIGZ2PM
Fixed High Range Instantaneous 4
LSHPM
LSHGPM
LSHGZ1PM
LSHGZ2PM
1 Add suffix to basic trip unit product number.
2 For single-phase 3 wire or 3-phase, 4-wire applications, order appropriate neutral current sensor separately, page 8-123.
Defeatable Ground Fault (not UL Listed) is available. Use code GD in place of G.
3 Requires purchase of Zone Selective Interlock module(s) Type TIM1 (120 Vac control voltage).
4 Not available on 4000A stationary breaker frame.
Control Units
Switch Envelope Switch Frame Sensor Product
Size (Amperes) Size (Amperes) (Amperes) Number
D208
800 800 800
D208T2
D210
1000
D210T2
1600 1600
D216
1600
D216T2
D220
2000 2000 2000
D220T2
D210
1000
D210T2
D220
2500 2000
D220T2
3000
D325
2500
D325T2
D330
3000 3000
D330T2
D440
4000 4000 4000
D440T2
Electrical Operator
The electrical operator mounts inside the front cover of the manually operated breaker.
This accessory can be added to any Power Break II breaker in the factory or the field
to provide electrical spring charging and charge indication. For remote closing, the
remote close solenoid must be ordered separately. All breakers are prewired to dedi-
cated secondary terminals for easy field installation. When electrical operation is used,
either a shunt trip or an undervoltage release must be ordered separately.
Shunt Trip
The shunt trip accessory is an electronic module, which provides remote control capabil-
ity to open the circuit breaker. When activated, the shunt trip module sends a signal to
the trip unit to open the breaker. This allows the trip unit to record, display, distinguish
and communicate (in MicroVersaTrip PM trip units) that the opening event was initiated
by the shunt trip device. The shunt trip is continuously rated and requires no cut-off
switch. When energized, the shunt trip supplies +24Vdc power to the trip unit to power
the display.
Auxiliary Switch
An auxiliary switch signals the circuit breakers primary contact position (i.e., OPEN or
CLOSED) to other devices, such as indicating lights, relays or logic circuits. This enables
the user to provide remote indication, interlocking or control operations as a function of
breaker primary contact position. The auxiliary switch operation is independent of the
method by which the breaker is opened or closed. The auxiliary switch does not distin-
guish between a "tripped" or "open" condition. The auxiliary switch contacts follow the
main breaker contacts on opening and precede them on closing.
Auxiliary switch modules are available with 4, 8 or 12 NO/NC (SPDT) switches for control
power duty ac/dc ratings. When ordered for field installation, an auxiliary switch module
comes pre-wired to its own terminal board, which mounts with one screw to the left of
the breaker. A special accessory, available for draw out breakers, comes pre-wired to the
breaker secondary disconnect. All switch ratings are 6A at 120V-600 Vac, 1/2A at 125
Vdc and 1/4A at 250 Vdc.
Auxiliary Switch with
Pre-wired Secondary Terminals
for Stationary Breaker
Auxiliary Switches for Stationary Breakers
No. of SPDT
Ratings Ratings Switch Elements Field Installable Factory Installed
Vac Vdc (Contacts) Product Number Product Number
240 125-250 4 SPAS240AB4R SPAS240AB4
240 125-250 8 SPAS240AB8R SPAS240AB8
240 125-250 12 SPAS240AB12R SPAS240AB12
600 125-250 4 SPAS600AB4R1 SPAS600AB41
600 125-250 8 SPAS600AB8R1 SPAS600AB81
1600 Vac module not UL Listed.
Door Interlock
The door interlock provides interlocking of the circuit breaker compartments hinged
door so that the breaker must be in the "OFF" position before the door can be opened.
The door interlock is defeatable with a small tool to allow authorized access.
Lug Kits
Kits accept Cu/AI wire and are suitable for direct mounting to the breaker. When order-
ing Type TPLUG kits, order one kit per line or load pole. Example: A complete set of lugs
for the line side of an 800A frame, 400A trip breaker would be Qty 3-TPLUG106 lugs. Type TPLUG206
When ordering TSLUG kits order one kit per line or load side; TSLUG kits require use of
T-studs. Example: A complete set of lugs for a 3000A frame, 2500A trip breaker would be
Qty 1-TSLUG25. T-Studs would also be required.
Circuit Breaker Max Rating Product Lug Max. Cables Wire Range
Envelope Size (Amperes) (Amperes) Number Per Kit Per Pole kcmil Cu/AI
400 TPLUG106 1 1 (2) #2 2-600
600 TPLUG206 1 2 (2) #2 2-600
800
800 TPLUG308 1 3 (3) 300-750
800 TPLUG1084 1 3 3/0-800
800 TPLUG1084 1 6 3/0-800
1600
1600 TPLUG408 1 4 500-800
2000 TPLUG1084 1 6 3/0-800 Type TPLUG408
800 TSLUG08 9 3 3/0-800
2000
1200 TSLUG12 12 4 3/0-800
1600 TSLUG16 15 5 3/0-800
2000 TSLUG20 18 6 3/0-800
3000 2500 TSLUG25 21 7 3/0-800
3000 TSLUG30 27 9 3/0-800
4000 4000 TSLUG40 27 9 3/0-800
4For use with adapter kit only. See table above.
Type TPLUG308
Type TSLUG20
T-Studs
T-studs mount directly to the breaker, and can be rotated for either vertical or horizontal
bus connection. 4000 ampere T-studs are for vertical bus bars only. Product number
includes one stud. Both copper and aluminum T-studs are tin-plated.
1Aluminum
2Copper
3Extra long stud. Alternate with SPS40FCC for ease of installation.
4Supplied with integral T-stud
Trimplate
Factory Installed Field Installable
Product Number Product Number
SPTRIMPLATE SPTRIMPLATER
The hand-held Portable Battery Pack provides an independent Supplies isolated bus
power source for EntelliGuard TU, microEntelliGuard, voltage signal to
EntelliGuard TU and One set of 3 voltage conditioners
MicroVersaTrip Plus and MicroVersaTrip PM trip units as an MicroVersaTrip PM required for each voltage sensing
alternative to a test set. The battery pack is used to power up the trip units. location. PTs also required. PLVC1G01
trip unit to set or adjust trip set points when the breaker is on the
bench or otherwise not powered up. For microEntelliGuard trip
units, the battery pack connects to the trip unit through the Reference
15-pin connector. A battery pack adapter cable is required. Instructions GEH-5946
Features
Draw-outs through 4000 amperes are UL Listed, 100% rated
Modular design for simplified installation6 basic sizes800, 1600, 2000, 2500 ,
3000 , 4000 5 inch pole centers
Screw racking mechanism provides positive racking motion
Self aligning primary and secondary disconnects
Four position draw-outengaged, test, disengaged, fully withdrawn
simplifies system testing and inspection
Breaker position indicator clearly shows breaker position
Provisions for padlocking breaker in test or disengaged position
Mechanical interlock logic prevents movement of a closed breaker
Suitable for reverse feeding
OEM Substructures
Substructures are available for both standard and Hi-Break Power Break II breakers.
Holes are provided for bolting on a shelf or supports. Holes are also provided in the pri-
mary stabs for bolting to busbars or terminal lugs. Substructure secondary disconnects
are ordered and priced separately. Order Hi-Break substructures for use with Power 1600-ampere substructure for
Break II switches. standard break breaker
BE H E
Top Feed 3000A 480-600Vac 180 THPC3630ET2 HPC Switch, Top Feed
Top Feed 4000A 480-600Vac 505 THPC3640ET2
SE
Bottom Feed 800A 120-240Vac 75 THPR3608BET1
RS P C
Bottom Feed 1200A 120-240Vac 80 THPR3612BET1
Bottom Feed 1600A 120-240Vac 80 THPR3616BET1
Bottom Feed 2000A 120-240Vac 165 THPC3620BET1
Bottom Feed 2500A 120-240Vac 180 THPC3625BET1
U W ,
Bottom Feed 3000A 120-240Vac 180 THPC3630BET1
N NE TE
.
Bottom Feed 4000A 120-240Vac 505 THPC3640BET1
Bottom Feed 800A 480-600Vac 75 THPR3608BET2
Bottom Feed 1200A 480-600Vac 80 THPR3612BET2
Bottom Feed 1600A 480-600Vac 80 THPR3616BET2
CT R LE
Bottom Feed 2000A 480-600Vac 165 THPC3620BET2
Bottom Feed 2500A 480-600Vac 180 THPC3625BET2
Bottom Feed 3000A 480-600Vac 180 THPC3630BET2
Bottom Feed 4000A 480-600Vac 505 THPC3640BET2
U O O
M
D F S
For service or feeder disconnects not requiring ground fault protection. Includes fuse- Type THPR, 800-1600A
mounting hardware and door-catch interlock bracket. Fuses not included. HPC Switch, Bottom Feed
Source Ampere Net Weight Product
Configuration Rating Lbs. (Approx.) Number
PR E 9 :
HPC Switches with Integral Ground Fault Protection for Solidly Grounded Systems
Integral Ground Fault with 3-Phase Sensor, Adjustable Pick-up, Adjustable Time-Delay,
Test Function, and Mechanical Ground Fault Indicator
Source Ampere Net Weight Product
Configuration Rating Lbs. (Approx.) Number
Top Feed 800A 105 THPR3608G3T
Top Feed 1200A 105 THPR3612G3T
Top Feed 1600A 105 THPR3616G3T
Top Feed 2000A 195 THPC3620G3T
Top Feed 2500A 210 THPC3625G3T
Top Feed 3000A 210 THPC3630G3T
Top Feed 4000A 540 THPC3640G3T
Bottom Feed 800A 105 THPR3608BG3T
Bottom Feed 1200A 105 THPR3612BG3T
Bottom Feed 1600A 105 THPR3616BG3T
Bottom Feed 2000A 195 THPC3620BG3T HPC Switches with
Bottom Feed 2500A 210 THPC3625BG3T
Bottom Feed 3000A 210 THPC3630BG3T
Integral Ground Fault Protection
Bottom Feed 4000A 540 THPC3640BG3T
.
BE H E
SE
HPC Switches with Integral Ground Fault Alarm only for Solidly Grounded Systems
RS P C
Integral Ground Fault with 3-Phase Sensor, Adjustable Pick-up, Adjustable Time-Delay,
Test Function, and Mechanical Ground Fault Indicator
Source
U W ,Ampere Net Weight Product
N NE TE
Configuration Rating Lbs. (Approx.) Number
Top Feed 800A 105 THPR3608GA3
Top Feed 1200A 105 THPR3612GA3
Top Feed 1600A 105 THPR3616GA3
CT R LE
Includes fuse-mounting hardware and door-catch interlock bracket. (Fuses not included)
NOTE: The 800-3000 ampere integral ground fault HPC switches can easily be installed in the space occupied by
PR E 9 :
a manual HPC switch of the same ampere rating. The 4000 ampere switch, being 3 inches wider, may require
G TE
some modification.
NOTE: Integral ground fault tripping is accomplished by a low-energy, flux-shifting tripping mechanism and is Integral Ground Fault HPC Pick-up and
not suitable for remote (paralleled) tripping. If remote tripping is required, add suffix RT1 120-240Vac or Delay Time-current Curves
PA N O
TI FO 2 UF NA TS
L A 1 TO A N I G I A R
O R 01 A L
S. E . -
AL -2 R M R P
Neutral Current Sensor - Solid
N N 4 C
ST E 9 IO ES O NT
IN G PR H OR E
W
PA D T C F E M
E E I D C
SE UR SW SE L A
EP
SH P R T 3 X 3 N L 0 0 0 8 1
Char 1-3 Char 4 Char 5 Char 6 Char 7 Char 8 Char 9 Char 10 Char 11 Char 12 Char 13 Char 14 Char 15
Auxiliary Switch,
Fusible Switch Trimplate
SHP = HPC 1 = 4-240V, None
New Generation
Closing Solenoid,
Frame Size
Door Interlock, Counter
R = Small Frame
8 = None, Yes, None
Feed
T = Top Electric Operator, Push Button Cover,
Hidden On
Frame Rating 0 = None, None, None
3 = 800A
Metering, RELT, Communication, Relays, ZSI Undervoltage Release, Blown Fuse Provision
X = Metering-Current, RELT-None, 0 = None
Communication- None, Relays- None, ZSI- None
Bell Alarm, Bell Alarm with Lock Out, Kirk Key Protection
TU Protection
0 = None, None, None
3 = Ground Fault
Character 8 TU Protection Character 11 Bell Alarm, Bell Alarm with Lock Out, Kirk
Character 8 Key Protection (Continued)
Fuse Only X 240 240 4 M
I (Switchable) 1 240 600 4 N
IG (I Switchable) 8 600 None 4 R
IGA (I Switchable) 9 600 240 4 S
IGDA (All Switchable)1 A 600 600 4 T
G 3
GA 4
GDA (All Switchable)1 5
Character 12 Undervoltage Release, Blown Fuse Provision
1G switchable by password only
Undervoltage Release Blown Fuse Provision Character 12
None None 0
Character 9 Switch Rating 24 Vac None 1
Character 9 48 Vac None 2
800A N 120 Vac None 3
1200A R 208 Vac None 4
1600A U 240 Vac None 5
2000A W 480 Vac None 6
2500A 1 600 Vac None 7
3000A 2 12 Vdc None 8
4000A 5 24 Vdc None 9
48 Vdc None A
125 Vdc None B
Character 10 Shunt Trip/ Blown Fuse Provision 250 Vdc None C
120 Vac W
Voltage with Lockout without Lockout Blown Fuse Provision Character 10
208 Vac X
None None 0
240 Vac Y
12 Vdc None H
24 Vac/24 Vdc None J
48 Vac/48 Vdc None K
120 Vac/125 Vdc None L Character 13 Electric Operator, Push Button Cover, Hidden On
208 Vac None M Electric Operator Push Button Cover Hidden On Character 13
240 Vac/250 Vdc None N None None None 0
480 Vac None P 120 Vac None None 1
600 Vac None R 240 Vac None None 2
120 Vac V 24 Vdc None None 3
208 Vac W 48 Vdc None None 4
240 Vac Y 72 Vdc None None 5
12 Vdc None 1 125 Vdc None None 6
24 Vac/24 Vdc None 2 None Yes None 8
48 Vac/48 Vdc None 3 120 Vac Yes None 9
120 Vac/125 Vdc None 4 240 Vac Yes None A
208 Vac None 5 24 Vdc Yes None B
240 Vac/250 Vdc None 6 48 Vdc Yes None C
480 Vac None 7 72 Vdc Yes None D
600 Vac None 8 125 Vdc Yes None E
120 Vac S None None Yes G
208 Vac T 120 Vac None Yes H
240 Vac U 240 Vac None Yes J
24 Vdc None Yes K
48 Vdc None Yes L
72 Vdc None Yes M
Character 11 Bell Alarm, Bell Alarm with Lock Out, Kirk
125 Vdc None Yes N
Key Protection None Yes Yes R
Bell Alarm Bell Alarm with Lock Out Kirk Key Protection Character 11 120 Vac Yes Yes S
None None None 0 240 Vac Yes Yes T
None 240 None 1 24 Vdc Yes Yes U
None 600 None 2 48 Vdc Yes Yes V
240 None None 4 72 Vdc Yes Yes W
240 240 None 5 125 Vdc Yes Yes X
240 600 None 6
600 None None 8
600 240 None 9
600 600 None A
None None 4 G
None 240 4 H
None 600 4 J
240 None 4 L
Character 14 Closing Solenoid, Door Interlock, Counter Character 15 Auxiliary Switch, Trimplate
Closing Solenoid Door Interlock Counter Character 14 Auxiliary Switch Trimplate Character 15
None Yes None 8 None None 0
120 Vac Yes None 9 4-240V None 1
240 Vac Yes None A 8-240V None 2
24 Vdc Yes None B 12-240V None 3
48 Vdc Yes None C 4-600V None 4
72 Vdc Yes None D 8-600V None 5
125 Vdc Yes None E None Yes 8
None Yes Yes R 4-240V Yes 9
120 Vac Yes Yes S 8-240V Yes A
240 Vac Yes Yes T 12-240V Yes B
24 Vdc Yes Yes U 4-600V Yes C
48 Vdc Yes Yes V 8-600V Yes D
72 Vdc Yes Yes W
125 Vdc Yes Yes X
THP R 2 3 6 08 T
Frame Size
R = Small Frame (800A-1600A) Switch Rating
C = Large Frame (2000A-4000A) 08 = 800A
L = Long Frame (42 4000A w/ GF, Retrofill only) 12 = 1200A
16 = 1600A
Construction 20 = 2000A
2 = New Generation 25 = 2500A
25 = 2500A
40 = 4000A
Poles
3 = 3 Pole
Voltage
6 = 600V
SP AS 240 AB4 R
HPC Switch Extender
R = Field installable kit
Device Type
Blank = Factory installed
AS = Auxiliary switch1
BAA = Bell alarm, alarm only1 Auxiliary Switch Extender
BAL = Bell alarm with lockout1 AB4 = Auxiliary switch, type AB with 4 elements
COUNTER = Mechanical counter1 AB8 = Auxiliary switch, type AB with 8 elements
DIL = Defeatable door interlock AB12 = Auxiliary switch, type AB with 12 elements
E = Electric operator1
K4 = Kirk key lock (4 maximum)1 Voltage, unless otherwise stated
PBCOVER = Pushbutton cover1 012 = 12 Vdc
RCS = Remote close solenoid1 024 = 24 Vdc
ST = Shunt trip 048 = 48 Vdc
STL = Shunt trip with lockout1 120/125 = 120 Vac or 125 Vdc
UV = Undervoltage release 240/250 = 240 Vac and 250 Vdc
250 = 250 Vdc
480 = 480 Vac
600 = 600 Vac
08 = 800 A 25 = 2500 A
16 = 1600 A 30 = 3000 A
20 = 2000 A 40 = 4000 A
1Device Product Number requires an extender R for field installable kit version only.
NOTE: This information is provided only for use interpreting product numbers. It cannot be used to build product numbers.
G F 1 0 8 L W X X X R X X X X
Char 1-2 Char 3 Char 4 & 5 Char 6 & 7 Char 8 Char 9 Char 10 Char 11 Char 12 Char 13 Char 14 Char 15
Frame Rating
Reserved
1 = 800A
Sensor Rating
08 = 800A
Reserved
OC and GF Protection Packages
LW = GF Only
Character 1 & 2 EntelliGuard Control Unit Form Character 8 Zone Selective Interlocking
Character 1 & 2 Character 8
HPC, New Generation GF None X
G user selectable Z
Z+IOC user selectable T
Character 3 Frame Ratings
Character 3
Character 9 Advanced Features and Communications
800A 1
1600A 2 Character 9
2000A 3 None Selected X
2500A 4 RELT 1
3000A 5 RELT+Modbus 2
4000A 7 Modbus-Adv Meter+WFC +RELT 6
Note: Use 1600A CT w/ 1200A rating plug for 1200A HPC frame. Modbus-Adv Meter+WFC+RELT+relay 8
Modbus Only (No RELT) A
Adv Metering, Modbus (No RELT) D
Character 4 & 5 Sensor Rating (Amperes) Adv Metering, Modbus, Relays (No RELT) E
Character 4 & 5
800A 08
1600A 16 Character 10 Manual/Auto Trip Reset
2000A 20 Character 10
2500A 25 None X
3000A 30
4000A 40
Character 11 Original Factory or Replacement Control Unit
Character 6 & 7 OC and GF Protection Packages Character 11
Factory F
Character 6 & 7 Replacement R
Fuse Only LZ
I (Switchable) S1
IG (I Switchable) S2
IGA (I Switchable) S3
IGDA (All Switchable)1 S4
GDA (All Switchable)1 S5
G LW
GA LY
1G switchable by password only
4000A 139C4114 sh 6 464 540
5-TS40FCA
IT NE E TU HP D
CH W P R C
Application Information HPC Switches without Integral Ground Fault Protection
S W R . FA O R A N
Data in the table below pertains to Type HPC switches without integral ground devices.
G D
Ampere Outline Approx. Shipping Approx. Net Connectors
Rating Drawing Weight (Lbs.) Weight (Lbs.) Product Number
E
800A 139C4219 85 75 1
N
TS20FCA
2000A 139C4114 sh 2 190 165
E
(Optional)
PC 2 0 N A O
2500A 139C4114 sh 3 205 180
TS25FCA
(Optional)
TS30FCA
H - 1 2 A AT T I
3000A 139C4114 sh 3 205 180
(Optional)
A
4000A
F 139C4114 sh 6 429 505
1-TS40LFCA
C
TO M D A
5-TS40FCA
R ES S LIC
E
(Cubic Top and Bottom to Ground C Min Height D Min Width E Mounting4 or Insulation
U
Rating Inches) (Square Inches) (Inches) (Inches) (Inches) Depth (Inches) (Inches)
S
IO CH ION PP
.
800A 8400 23 2 28 25 8.66 3.5
1200A-1600A 11100 63 2 30 25 8.66 3.5
ES
2000A 28000 63 2 40 25 9.38 3
2500A 28000 172 2 40 25 9.38 3
4
PR IT S : A
4000 40.00 22.387 11.12 9.24 18.19 Minimum OEM Enclosure Dimensions
7.75 (A & C)
and Ventilation Requirements
Note: For dimensions of neutral current sensor to be used with integral ground fault switches, page 9-34.
1See page 9-33 for optional connectors.
2Dimensions are minimum requirements and do not represent enclosures on page 9-22.
3Ventilating openings can be in alternate locations but must provide equivalent ventilating areas.
9
4For switches with integrally mounted three-phase Ground Fault current sensor (Product Numbers with suffix G3T,
G3R, GA3, BG3T, BGA3, BG3R) add 1.62 inch to dimension E.
5For complete switch dimensions order outline drawings from application information above.
6For Product Numbers with suffix B (bottom-feed), invert drawing.
7With integral ground fault, overall width is 24 inches.
Switch Dimensions
(For Estimating Only)
Note: For dimensions of neutral current sensor to be used with integral ground fault switches,
see outline drawings: 139C5016SH1 & SH2 (TSVG types) and 10112973P1 (SSVG types).
1Ventilating openings can be in alternate location but must provide equivalent ventilating areas.
How to Order
1. Determine your new HPC 15-digit part number by using the Configurator (contact your authorized GE Distributor) and refer to the
Buylog for complete list of options.
2. Check EliteNet for price and availability (For access to EliteNet, contact your authorized GE Distributor). Note: Because of multiple
possible combinations, only product numbers that have been ordered are in EliteNet. If the product number you are interested in is
not in EliteNet, email the request to GE.1STOP_REPLY@GE.com to add it to the system.
3. Once the product number is loaded, the order can be placed via EliteNet.
4. Note: Neutral CTs and T-Studs are ordered separately from the 15-digit product number.
Accessories
The complete line of new generation HPC switch accessories may be either factory or
field installed to meet user needs. The electronic shunt trip, the bell alarm, the bell alarm
with mechanical lockout, and the undervoltage release modules are drop-in from the
front of the switch, interchangeable across all frames, and require no field internal wiring
or switch disassembly. Auxiliary switch modules are available in groups of 4, 8 or 12,
NO/NC single-pole, double-throw (SPDT) switches. Their installation simply involves
removal of switch cover, installation of the switch module, routing of wiring and installa-
tion of the pre-wired terminal block and re-installation of the cover. Auxiliary switches
are also interchangeable across all new geneation HPC switch frames.
Electrical Operator
The electrical operator mounts inside the front cover of the manually operated switch.
This accessory can be added to any new generation HPC switch in the factory or the
field to provide electrical spring charging and charge indication. For remote closing, the
remote close solenoid must be ordered separately. All switches are prewired to dedi-
cated secondary terminals for easy field installation. When electrical operation is used,
either a shunt trip or an undervoltage release must be ordered separately.
Shunt Trip
The shunt trip accessory is an electronic module, which provides remote control capabil-
ity to open the switch. When activated, the shunt trip module sends a signal to the
control unit to open the switch. This allows the control unit to record, display, distinguish
and communicate that the opening event was initiated by the shunt trip device. The
shunt trip is continuously rated and requires no cut-off switch. When energized, the
shunt trip supplies +24Vdc power to the control unit to power the display.
Ratings Ratings Field Installable Factory Installed
Vac Vdc Product Number Product Number
12 SPST012R SPST012
24 24 SPST024R SPST024
48 48 SPST048R SPST048
120 125 SPST120R SPST120
208 SPST208R SPST208
240 250 SPST240R SPST240
Shunt Trip Module
480 SPST480R1 SPST4801
600 SPST600R1 SPST6001
1Kit contains externally mounted transformer.
Auxiliary Switch
An auxiliary switch signals the HPC switchs primary contact position (i.e., OPEN or
CLOSED) to other devices, such as indicating lights, relays or logic circuits. This enables
the user to provide remote indication, interlocking or control operations as a function of
HPC switch primary contact position. The auxiliary switch operation is independent of
the method by which the HPC switch is opened or closed. The auxiliary switch does not
distinguish between a "tripped" or "open" condition. The auxiliary switch contacts follow
the main HPC switch contacts on opening and precede them on closing.
Auxiliary switch modules are available with 4, 8 or 12 NO/NC (SPDT) switches for control
power duty ac/dc ratings. When ordered for field installation, an auxiliary switch module
comes pre-wired to its own terminal board, which mounts with one screw to the left of
the HPC switch. All switch ratings are 6A at 120V-600 Vac, 1/2A at 125 Vdc and 1/4A at
250 Vdc.
Auxiliary Switch with
Pre-wired Secondary Terminals
No. of SPDT
Ratings Ratings Switch Elements Field Installable Factory Installed
Vac Vdc (Contacts) Product Number Product Number
240 125-250 4 SPAS240AB4R SPAS240AB4
240 125-250 8 SPAS240AB8R SPAS240AB8
240 125-250 12 SPAS240AB12R SPAS240AB12
600 125-250 4 SPAS600AB4R1 SPAS600AB41
600 125-250 8 SPAS600AB8R1 SPAS600AB81
1600 Vac module not UL Listed.
Maintenance/Repair Parts
Description Product Number
Top Cover and Rating Labels SPBIICOVER1
Visible On Button Conversion SPPBRONR
1Special handling and order entry required to preserve UL Listing of switch.
Contact Post Sale Service for additional details of special process.
Door Interlock
The door interlock provides interlocking of the switch compartments hinged door so
that the switch must be in the "OFF" position before the door can be opened. The door
interlock is defeatable with a small tool to allow authorized access.
SwitchesDirect Mounting
Field installed only. Kits consist of lugs and hardware for direct Trimplate
Factory Installed Field Installable
mounting to switch terminal straps (multiple-hole tang lugs) or lugs Product Number Product Number
for mounting to 800 ampere terminal adapter kit. Order three kits SPTRIMPLATE SPTRIMPLATER
for three-pole line or load end. For 1600-ampere, copper conduc-
tors must be used.
Accessory Wire Range Product
Ampere Rating Type Cu/Al Number
Lug Kit Line
800A (3) 300-750 THPCLUG308
& Lug Kit Load
1200A, 1600A Lug Kit Line (4) 500-800 kcmil TPLUG408
1200A, 1600A Lug Kit Load (4) 500-800 kcmil THPCLUG408
Reference Publications
Auxiliary Switch Module GEH6274
Bell Alarm Alarm Only GEH6275
Door Interlock GEH6276
Lugs & Adapters for 8002000 A Frames GEH4546
Bell Alarm with Lockout GEH6278
Key Interlock Mounting Provision GEH6279
Mechanical Counter GEH6280
Motor Operator Mechanism GEH6281
Push Button Cover GEH6282
Remote Close GEH6283
Shunt Trip and Shunt Trip with Lockout (except 480 and 600 Vac) GEH6284
Shunt Trip and Shunt Trip with Lockout, 480 & 600 Vac GEH6519
Undervoltage Release (except 480 and 600 Vac) GEH6285
Undervoltage Release, 480 & 600 Vac GEH6520
Instructions, HPC Heat Sink Installation DEH41694
Instructions, HPC Blown Fuse Protector DEH41695
EntelliGuard TU Trip Unit DEH4567
HPC Switches, New Generation, Users Guide DEH41689
Time Current Curves HPC Switches, New Generation, Ground Fault DES121
Time Current Curves HPC Switches,
New Generation, Adjustable Selective Instantaneous Trip,
Reduced Energy Let-Through (RELT) DES-122
HPC Switches, New Generation, Instantaneous Protection Guide DEE-715
Product Description
QMR and QMW switches (30-200 amperes), fuse and no-fuse kits
are UL Recognized Components, File E-36152, and UL Recognized
to Canadian safety requirements under the Component Recognition
Program of Underwriters Laboratories Inc.
The 30-200 ampere fusible switches are UL Recognized for use
on circuits capable of delivering not more than 200,000 rms
symmetrical amperes at 240 or 600Vac when fused with Class R
rated size fuses. Refer to the table 7-3 for the appropriate Class R
Fusing Kit. They are suitable for use with Type STDA flange handles
and variable depth operating mechanisms on page 9-28.
Fuse and No-Fuse Kits (Includes load block, clips, and lugs)
Product Switch
Number Description of Kit Product Number Fuse Type No. of Poles Lug Wire Size
THMC31002 No Fuse THMC31 or THMS31 No Fuse 3 Wire Keeper Term.
for #14-8 CU
THMC3200 No Fuse THMC32 or THMS32 No Fuse 3 CU 14-2 AL 12-2
THMC3300 No Fuse THMC33 or THMS33 No Fuse 3 CU 14-0 AL 12-0
THMC3400 No Fuse THMC34 or THMS34 No Fuse 3 6-250 kcmil CU-AL
THMC31211 30A, 240Vac/250Vdc THMC31 or THMS31 NEC Standard 3 Wire Keeper Term.
for #14-8 CU
THMC32221 60A, 240Vac/250Vdc THMC31 or THMS31 NEC Standard 3 Wire Keeper Term.
for #14-8 CU
THMC31611 30A, 600Vac HMC31 or THMS31 NEC Standard 3 TWire Keeper Term.
and Class J for #14-8 CU
THMC32621 60A, 600Vac THMC31 or THMS31 NEC Standard 3 Wire Keeper Term.
and Class J for #14-8 CU
THMC3363 100A, 240Vac/250Vdc THMC32 or THMS32 NEC Standard 3 CU 14-2 AL 12-2
100A, 600Vac and Class J
THMC3364 200A, 600Vac THMC33 or THMS33 NEC Standard 3 CU 14-0 AL 12-0
and Class J
THMC3464 200A, 240Vac/250Vdc THMC34 or THMS34 NEC Standard 3 6-250 kcmil CU-AL
200A, 600Vac and Class J
THMC3465 400A, 600Vac THMC34 or THMS34 NEC Standard 3 6-250 kcmil CU-AL
and Class J
No-fuse ratings indicate switch capability as permitted by UL 508 (Ind. Cont. Equip.), additional hp ratings correspond to commercially available fuses.
For DC use outer poles.
1Can be used for one-step underfusing for next higher current-rated disconnect.
2Maximum UL listing 20 hp. at 600V.
Product Description
These 30-600 ampere disconnect switches are complete with
Class H fuse clips except where noted, line/load lugs and handle
operators, all factory assembled, and are mounted on a heavy-
gauge steel backplate. They are UL Recognized Components, File
E-36152, and UL Recognized to Canadian safety requirements
under the Component Recognition Program of Underwriters
Laboratories Inc.
The 30-200 ampere fusible switches are UL Recognized for use on
circuits capable of delivering not more than 200,000 rms symmet-
rical amperes at 240 or 600Vac when fused with Class R rated
size fuses. Refer to the table below for the appropriate Class R
Fusing Kit. Class H Fuse Clips are standard. Suitable for NEMA 1
QMR Disconnect with TDR Handle
and NEMA 12 enclosures.
Assembled with Lugs, Fuse Clips and Handle Operators Horsepower Ratings
Disconnect Switch Max. HP Rating Max. HP Rating Max. HP Rating Max. HP Rating
Duty Type Rating (Amperes) @ 240Vac 3-Phase @ 480Vac 3-Phase @ 600Vac 3-Phase @ 250 Vdc Product Number
Heavy Duty QMR 30A 7.5 20 20 5 THMR3100
Heavy Duty QMR 30A 7.5 5 THMR3121
Heavy Duty QMR 30A 7.5 15 20 5 THMR3161
Heavy Duty QMR 60A 20 40 50 10 THMR3200
Heavy Duty QMR 60A 15 10 THMR3222
Heavy Duty QMR 60A 30 50 10 THMR3262
Heavy Duty QMR 100A 30 60 75 20 THMR3300
Heavy Duty QMR 100A 30 60 75 20 THMR33631
Heavy Duty QMR 200A 60 125 150 40 THMR3400
Heavy Duty QMR 200A 60 125 150 40 THMR34641
Heavy Duty QMR 400A 125 250 350 50 THMA35NF
Heavy Duty QMR 400A 125 50 THMA3525
Heavy Duty QMR 400A 125 250 350 THMA3565
Heavy Duty QMR 400A 125 250 350 THMA35J52
Heavy Duty QMR 400A 125 250 350 50 THMRB35NF
Heavy Duty QMR 400A 125 250 350 THMRB3565
Heavy Duty QMR 400A 125 250 350 THMRB35J52
Heavy Duty QMR 600A 200 400 500 50 THMA36NF
Heavy Duty QMR 600A 200 400 500 THMA3665
Heavy Duty QMR 600A 200 400 500 THMA36663
Heavy Duty QMR 600A 200 400 500 THMA36J62
Heavy Duty QMR 600A 200 400 500 50 THMRB36NF
Heavy Duty QMR 600A 200 400 500 THMRB36663
Heavy Duty QMR 600A 200 400 500 THMRB36J62
Heavy Duty QMR 600A 200 400 500 THMRB36L74
Premium Duty QMW 30A 7.5 5 THMCR3121
Premium Duty QMW 30A 7.5 15 20 5 THMCR3161
Premium Duty QMW 60A 20 40 50 10 THMCR3200
Premium Duty QMW 60A 15 10 THMCR3222
Premium Duty QMW 60A 30 50 10 THMCR3262
Premium Duty QMW 100A 30 60 75 20 THMCR3300
Premium Duty QMW 100A 30 60 75 20 THMCR3363
Premium Duty QMW 200A 60 125 150 40 THMCR3400
Premium Duty QMW 200A 60 125 150 40 THMCR3464
400 and 600 Ampere QMR units are UL Recognized on 100,000 Ampere rms circuits when fused with rated size Class J or R fuses.
Order Door Ring Interlock Kit343L483G4; Gasket Kit792A489G3.
400 and 600 Ampere switches with TDM handle have pendulum operation.
400 and 600 Ampere QMR units are UL Recognized on 100,000 Ampere rms circuits when fused with rated size Class J or R fuses.
1Field convertible to 250 Volt fusing.
2Supplied with Class J fuse clips.
3600 Ampere, 600 Volt Class H fused to Class J fusing. Order kit Product Number THJ6. One kit required per switch. 400 Ampere units can be field converted by moving the
fuse block toward the switch.
4Supplied with Class L fuse clips.
400 and 600 Ampere QMR units are UL Recognized on 100,000 Ampere rms circuits when fused with rated size Class J or R fuses.
Order Door Ring Interlock Kit343L483G4. Gasket Kit792A489G3.
400 and 600 Ampere switches with TDM handle have pendulum operation.
400 and 600 Ampere QMR units are UL Recognized on 100,000 Ampere rms circuits when fused with rated size Class J or R fuses.
1Field convertible to 250 Volt fusing.
2Supplied with Class J fuse clips.
3600 Ampere, 600 Volt Class H fused to Class J fusing. Order kit Product Number THJ6. One kit required per switch. 400 Ampere units can be field converted by moving the
fuse block toward the switch.
4Supplied with Class L fuse clips.
Assembled Switches with Lugs, Fuse Clips and Handle Operators (Continued)
Ampere Fuse Clip Rating Fuse Clip Rating
Duty Type Rating (Ampere) @ 250Vdc Max. (Ampere) @ 600Vac Max. Handle Style Lug Wire Size Product Number
Premium Duty QMW 30A 30 TDR Rotary Handle Wire Keeper, THMCR3121
Term. for #14-8 Cu
Premium Duty QMW 30A 30 TDR Rotary Handle Wire Keeper, THMCR3161
Term. for #14-8 Cu
Premium Duty QMW 60A No Fuse No Fuse TDR Rotary Handle CU 14-2 AL 12-2 THMCR3200
Premium Duty QMW 60A 60 TDR Rotary Handle CU 14-2 AL 12-2 THMCR3222
Premium Duty QMW 60A 60 TDR Rotary Handle CU 14-2 AL 12-2 THMCR3262
Premium Duty QMW 100A No Fuse No Fuse TDR Rotary Handle 10-1/0 Cu/Al THMCR3300
Premium Duty QMW 100A 100 100 TDR Rotary Handle 10-1/0 Cu/Al THMCR3363
Premium Duty QMW 200A No Fuse No Fuse TDR Rotary Handle 6-250 kcmil Cu/Al THMCR3400
Premium Duty QMW 200A 200 200 TDR Rotary Handle 6-250 kcmil Cu/Al THMCR3464
400 and 600 Ampere QMR units are UL Recognized on 100,000 Ampere rms circuits when fused with rated size Class J or R fuses.
Order Door Ring Interlock Kit343L483G4. Gasket Kit792A489G3.
400 and 600 Ampere switches with TDM handle have pendulum operation.
400 and 600 Ampere QMR units are UL Recognized on 100,000 Ampere rms circuits when fused with rated size Class J or R fuses.
1Field convertible to 250 Volt fusing.
2Supplied with Class J fuse clips.
3600 Ampere, 600 Volt Class H fused to Class J fusing. Order kit Product Number THJ6. One kit required per switch. 400 Ampere units can be field converted by moving the
fuse block toward the switch.
4Supplied with Class L fuse clips.
Product Description
Type STDA Flange Handles and Variable Depth Operating
Mechanisms For Use With QMR/QMW 30-200A Disconnects
Designed to meet automotive duty specifications.
NEMA 12/13 and 4/4X, UL Recognized Components, File E-
57253, and UL Recognized to Canadian safety requirements
under the Component Recognition Program of Underwriters
Laboratories Inc.
For right- or left-hand flange mountingfield convertible.
Mounting dimensions to fit standard flange enclosures
8"-24" deep.
Drilling templates and detailed installation instructions.
Construction Details
Flange Handles Variable Depth Operating Mechanisms
Rugged aluminum alloy cast housing with provision for locking Plated steel yokes and integral mounting plates are 1/8-inch
in off position with up to three 3/16- to 5/16-inch diameter thick minimum.
padlocks. Operating yokes have toggle spring assist for positive
Optional provision for locking on by drilling hole in die casting. on/off operation.
O-ring seals for dust-tight/oil-tight duty. Mounting plates include positive yoke stops to prevent undue
Gusseted, 3/32-in. thick double-sided steel handle with large, wear on disconnect and circuit breaker toggle handles.
red-black self-extinguishing grade plastic grip. Threaded 3/8-in. dia. drive rod (16-in. lengthstandard, 22-in.
lengthoptional) provides simple variable depth connection
between flange-mounted handle and operating mechanism.
Suitable for use with Hoffman Bulletin A-25 or equivalent
enclosures.
Flange Handles
Nominal Length Installation Instruction Drilling Template Product
Enclosure Type (Inches) Number Number Number
NEMA Type 12/13 6 GEH-5314 GEH-5314 STDA1
NEMA Type 12/13 10 GEH-5314 GEH-5314 STDA2
NEMA Type 4/4X 6 GEH-5314 GEH-5314 STDA1X
NEMA Type 4/4X 10 GEH-5314 GEH-5314 STDA2X
Select individual QMR or QMW disconnect and fuse or no-fuse kit from page 9-24.
Reference Publications
Extended Drive Stud
Door Hardware GEH-5322
This optional drive stud permits locating the operating mechanism Auxiliary Contact Kit GEH-5323
Flange Stiffener Kit or Extended-Length Drive Rod GEH-5324
1 5/16 inches further to the left (when flange handle is on right Extended Drive Stud GEH-5325
side) or to the right (when handle is on left side) to accommodate Operating Mechanism:
specific mounting restrictions. TDOM1A through TDOM1B GEH-5315
TDOM2 GEH-5316
Used With Operating
Mechanism Product Number Product Number
TDOM1A, TDOM1B, TDOM2 TDS1
Overpack Kits
QMW disconnect switch, fuse kit with copper lugs, operating mechanism and STDA1 flange handle packed in a single carton.
QMW with Copper Lugs for Copper Cables Only and Class R Rejection Clips for Class R Fusing
Ampere Fuse Clip System Fuse Kit Prod. No. Variable Depth Operating Product
Rating Rating (Ampere) Voltage (or No-Fuse Kit Prod. No.) Mechanism Prod. No. Number
30A No Fuse No Fuse THMC3200CL TDOM1A STDAD3NF
30A 30 250Vdc THMC3121CLR TDOM1A STDAD332R
30A 30 600Vac THMC3161CLR TDOM1B STDAD336R
60A No Fuse No Fuse THMC3200CL TDOM1A STDAD6NF
60A 60 250Vdc THMC3222CLR TDOM1B STDAD662R
60A 60 600Vac THMC3262CLR TDOM1B STDAD666R
100A No Fuse No Fuse THMC3300CL TDOM1A STDAD1NF
250Vdc
100A 100 600Vac THMC3363CLR TDOM1B STDAD100R
200A No Fuse No Fuse THMC3400CL TDOM2 STDAD2NF
250Vdc
200A 200 600Vac THMC3464CLR TDOM2 STDAD200R
QMW with Copper Lugs for Copper Cables Only and Class J Clips for Class J Fusing
Ampere Fuse Clip System Fuse Kit Prod. No. Variable Depth Operating Product
Rating Rating (Ampere) Voltage (or No-Fuse Kit Prod. No.) Mechanism Prod. No. Number
30A 30 600Vac THMC3161CL TDOM1JA STDAD336J
30A 60 600Vac THMC3262CL TDOM1JB STDAD3362J
60A 60 600Vac THMC3262CL TDOM1JB STDAD666J
60A 100 600Vac THMC3363CL TDOM1JA STDAD6663J
100A 100 600Vac THMC3363CL TDOM1JA STDAD106J
100A 200 600Vac THMC3364CL TDOM1A STDAD1064J
200A 200 600Vac THMC3464CL TDOM2 STDAD206J
200A 400 600Vac THMC3465 TDOM2 STDAD2065J
Auxiliary switch (SPDT) for HCI rated .5 ampere at 125Vdc, .25 ampere at 250Vdc, 15 ampere at 480Vac. Product Number 343L296G2.
HCI switches, fuse and no-fuse kits, are listed in UL Recognized Component Index (WHTY2) for mounting in a vertical position, line side up. UL File E-36152.
Line shield included with THC31 and THC31S. All other line shields included with fuse-clip or no-fuse kits.
For Two-pole applicationsUse two poles of three-pole switch.
HCI switches, fuse and no-fuse kits, are listed in UL Recognized Component Index (WHTY2) for mounting in a vertical position, line side up. UL File E-36152.
Inside enclosure depth may be reduced to these depths while maintaining electrical spacingsrequires cutting handle shaft.
1Suitable for 25 hp @ 600 V but not UL listed.
2Basic switch with UL 600 Volt industrial control spacings only.
3For 30 ampere switch with 600 Volt enclosed switch spacing and 60 ampere terminals, order Product Number THC31SSE.
Basic Switch Rating Basic Switch Product Number Fuse Type Fuse Kit Rating Product Number
30 Ampere 3-Pole THC31S No Fuse No Fuse600 THC31001,3
30 Ampere 3-Pole THC31 NEC Standard 30A, 240Vac/250Vdc THC3121
30 Ampere 3-Pole THC31 NEC Standard 30A, 600Vac THC3161
30 Ampere 3-Pole THC31 Class J 30A, 600Vac THC31J1
30 Ampere 3-Pole THC31 NEC Standard 60A, 240Vac/250Vdc THC3122
30 Ampere 3-Pole THC31 NEC Standard 60A, 600Vac THC3162
30 Ampere 3-Pole THC31 Class J 60A, 600Vac THC31J2
60 Ampere 3-Pole THC32S No Fuse No Fuse600 THC32002
60 Ampere 3-Pole THC32 NEC Standard 30A, 240Vac/250Vdc THC32212
60 Ampere 3-Pole THC32 NEC Standard 30A, 600Vac THC32612
60 Ampere 3-Pole THC32 NEC Standard 60A, 240Vac/250Vdc THC32222
60 Ampere 3-Pole THC32 NEC Standard 60A, 600Vac THC32622
60 Ampere 3-Pole THC32 Class J 60A, 600Vac THC32J22
60 Ampere 3-Pole THC32 NEC Standard 100A, 240Vac/250Vdc THC32232
60 Ampere 3-Pole THC32 NEC Standard 100A, 600Vac THC32632
60 Ampere 3-Pole THC32 Class J 100A, 600Vac THC32J32
100 Ampere 3-Pole THC33S No Fuse No Fuse600 THC3300
100 Ampere 3-Pole THC33 NEC Standard 60A, 240Vac/250Vdc THC3322
100 Ampere 3-Pole THC33 NEC Standard 60A, 600Vac THC3362
100 Ampere 3-Pole THC33 NEC Standard 100A, 240Vac/250Vdc THC3323
100 Ampere 3-Pole THC33S NEC Standard 100A, 600Vac THC3363
100 Ampere 3-Pole THC33S Class J 100A, 600Vac THC33J3
100 Ampere 3-Pole THC33 NEC Standard 200A, 240Vac/250Vdc THC3324
100 Ampere 3-Pole THC33 NEC Standard 200A, 600Vac THC3364
100 Ampere 3-Pole THC33 Class J 200A, 600Vac THC33J4
200 Ampere 3-Pole THC34S No Fuse No Fuse600 THC3400
200 Ampere 3-Pole THC34 NEC Standard 100A, 240Vac/250Vdc THC3423
200 Ampere 3-Pole THC34 NEC Standard 100A, 600Vac THC3463
200 Ampere 3-Pole THC34 Class J 100A, 600Vac THC34J3
200 Ampere 3-Pole THC34 NEC Standard 200A, 240Vac/250Vdc THC3424
200 Ampere 3-Pole THC34 NEC Standard 200A, 600Vac THC3464
200 Ampere 3-Pole THC34 Class J 200A, 600Vac THC34J4
200 Ampere 3-Pole THC34 NEC Standard 400A, 240Vac/250Vdc THC3425
200 Ampere 3-Pole THC34 NEC Standard 400A, 600Vac THC3465
200 Ampere 3-Pole THC34 Class J 400A, 600Vac THC34J5
Basic Switch Rating Basic Switch Product Number Fuse Type Fuse Kit Rating Product Number
30 Ampere 3-Pole THC31S NEC Standard 30A, 600Vac THC31S611,3
30 Ampere 3-Pole THC31S Class J 30A, 600Vac THC31SJ11,3
30 Ampere 3-Pole THC31S No Fuse No Fuse600 THC31001,3
60 Ampere 3-Pole THC32S NEC Standard 60A, 600Vac THC32S62
60 Ampere 3-Pole THC32S Class J 60A, 600Vac THC32SJ2
60 Ampere 3-Pole THC32S No Fuse No Fuse600 THC32002
100 Ampere 3-Pole THC33S NEC Standard 100A, 600Vac THC3363
100 Ampere 3-Pole THC33S Class J 100A, 600Vac THC33J3
100 Ampere 3-Pole THC33S No Fuse No Fuse600 THC3300
200 Ampere 3-Pole THC34 NEC Standard 200A, 600Vac THC3464
200 Ampere 3-Pole THC34 Class J 200A, 600Vac THC34J4
200 Ampere 3-Pole THC34S No Fuse No Fuse600 THC3400
Auxiliary switch (SPDT) for HCI rated .5 ampere at 125Vdc, .25 ampere at 250Vdc, 15 ampere at 480Vac. Product Number 343L296G2.
HCI switches, fuse and no-fuse kits, are listed in UL Recognized Component Index (WHTY2) for mounting in a vertical position, line side up. UL File E-36152.
Line shield included with THC31 and THC31S. All other line shields included with fuse-clip or no-fuse kits.
For Two-pole applicationsUse two poles of three-pole switch.
HCI switches, fuse and no-fuse kits, are listed in UL Recognized Component Index (WHTY2) for mounting in a vertical position, line side up. UL File E-36152.
Inside enclosure depth may be reduced to these depths while maintaining electrical spacingsrequires cutting handle shaft.
TDR Handle
FD160J
Mechanical Specifications3
Product Mechanical Endurance Normal Operating Terminal Capacity / Terminal Capacity / Maximum Number of
Number Operations Torque Power Terminals Auxiliary Switch Terminals Auxiliary Circuits FD1100J and FD1200J
FD130CC 10000 27 #14 - #8 #14 - #12 4
FD130J 10000 27 #14 - #8 #14 - #12 4
FD130NF 10000 27 #14 - #8 #14 - #12 4
FD160J 10000 45 #14 - #4 #14 - #12 4
FD160NF1 10000 45 #14 - #4 #14 - #12 4
FD1100J 10000 107 #14 - #2 #14 - #12 4
FD1100NF 10000 107 #14 - #2 #14 - #12 4
FD1200J 10000 239 #6 - 250kcmil #14 - #12 4
FD1200NF 10000 239 #6 - 250kcmil #14 - #12 4
3See page 9-38 for additional Mechanical Specifications.
FD1100NF and FD1200NF
Switch Type Handle Type Enclosure Depth (Max.) Shaft Length Product Number
FD130 or FD1HA4X 10 15/64 (260) 166mm or FD1S166
FD160 6 17/32in.
FD130 or FD1HA4X 17 7/8 (454) 360mm or FD1S360
FD160 14 11/64in.
FD1100 or FD11HA 11 21/38 (296) 200mm or FD1S12
FD1200 7 7/8in.
FD1100 or FD11HA 16 15/64 (430) 319mm or FD1L12
FD1200 12 19/32in.
Auxiliary Switches
Other Accessories
Accessory Type Switch Type Comments Product Number
Terminal Shields FD130 Terminal shield for FD130TS
line or load side.
One shield supplied
with switch as standard.
Terminal Shields FD160 Terminal shield for FD160TS
line or load side.
One shield supplied
with switch as standard.
Terminal Shields FD1100 Terminal shield for FD1100TS
line or load side.
One shield supplied
with switch as standard.
Terminal Shields
Terminal Shields FD1200 Terminal shield for FD1200TS
line or load side.
One shield supplied
with switch as standard.
Shorting Links FD130 Package of 3. Use as FD130LNK
replacements in FD130NF
and FD160NF.
Shorting Links FD160 Package of 3. Use as FD160LNK
replacements in FD130NF
and FD160NF.
Shorting Links FD1100 For non-fused applications. FD1100LNK
Shorting Links FD1200 For non-fused applications. FD1200LNK
Fuse Covers FD130CC FD130CV1
FD130NF
Fuse Covers FD130J FD130JCV1
Fuse Covers FD160J FD160JCV1
FD160NF
Fuse Covers FD1100 FD1100JCV1
Fuse Covers FD1200 FD1200JCV1 Shorting Links
Auxiliary Switch All Package of 2. FD1ASCV1
Terminal Shields
Lug Kits
Fuse Covers
Lugs Kits
FD130CC 4 19/64 (109) 3 23/64 (85) 4 21/64 (110) 3 15/64 (82) 4 13/32 (112) M4
FD130J 4 19/64 (109) 3 11/32 (85) 4 21/64 (110) 3 15/64 (82) 5 15/64 (133) M4
FD130NF 4 19/64 (109) 3 23/64 (85) 4 21/64 (110) 3 15/64 (82) 4 13/32 (112) M4
FD160J 4 41/64 (118) 4 23/32 (120) 5 19/32 (142) 3 15/16 (100) 4 49/64 (121) M4
D A
FD160NF 4 41/64 (118) 4 23/32 (120) 5 19/32 (142) 3 15/16 (100) 4 49/64 (121) M4
FD1100J 6 21/32 (169) 6 7/32 (158) 7 11/64 (182) 4 9/64 (105) 4 59/64 (125) M6
FD1100NF 6 21/32 (169) 6 7/32 (158) 7 11/64 (182) 4 9/64 (105) 4 59/64 (125) M6
FD1200J 9 27/32 (250) 8 21/32 (220) 9 17/32 (242) 5 29/32 (150) 7 (178) M8
FD1200NF 9 27/32 (250) 8 21/32 (220) 9 17/32 (242) 5 29/32 (150) 7 (178) M8 B E
C
Approvals/Standards
UL Listed (UL 489)
CSA Certified (CSA 22.2 No. 4)
Meets service entrance requirements
CE Marked
Auxiliary Switches
Auxiliary Switches
Padlocking Device
Comments Product Number
For padlock with maximum D/061900-020
8mm or 5/16" diameter.
Padlocking Device
Inbus Key
Inbus Key
Lugs
Lugs
DILOS Weights
Product Number Weight (Lbs.) Weight (kg)
D/061312-201 1.2 0.54 kg
D/061314-201 1.2 0.54 kg
D/061315-201 1.2 0.54 kg
D/061324-201 1.6 0.73 kg
D/061326-201 1.6 0.73 kg
Approvals/Standards
UL Listed (UL 489)
IEC 947-1, 947-3
EN 60947-3
DILOS 1
DILOS 2
General Information
Types QB, QMS, QL ..................................................................................10-2 Servicenter Mini-Unit Substations
General Purpose Integral Transformer and Distribution Center...................10-32
Single-Phase DOE 2016 Efficiency, Aluminum...........................10-4 Single-Phase and Three-Phase DOE 2016 Efficiency ..........10-33
Single-Phase DOE 2016 Efficiency, Copper.................................10-5 Outlines, Dimensions, Wiring Diagrams.....................................10-34
Three-Phase DOE 2016 Product Number Nomenclature.....10-6 Totally Enclosed, Nonventilated TENV ..............................10-35
Three-Phase DOE 2016 Efficiency, Aluminum ...........................10-9 Aluminum and Copper DOE 2016 Efficiency ...........................10-36
Three-Phase DOE 2016 Efficiency, Copper...............................10-11 Midtapped
K-Factor Aluminum DOE 2016 Efficiency......................................................10-37
Three-Phase DOE 2016 Efficiency, Aluminum.........................10-12 Copper DOE 2016 Efficiency............................................................10-38
Three-Phase DOE 2016 Efficiency, Copper...............................10-16 Drive Isolation
K-Factor Low Noise Three-Phase.............................................................................................10-40
Three-Phase DOE 2016 Efficiency, Aluminum.........................10-20 Accessories and Lugs ..............................................................10-42
Three-Phase DOE 2016 Efficiency, Copper...............................10-22 Enclosure Parts.........................................................................10-44
Low Noise Wiring Diagrams ......................................................................10-45
Three-Phase DOE 2016 Efficiency, Aluminum.........................10-24 Dimensions ................................................................................10-46
Three-Phase DOE 2016 Efficiency, Copper...............................10-25 General Purpose Transformers in Enclosures
Noise Isolation Guard I Single-Phase............................................................................................10-48
Three-Phase DOE 2016 Efficiency, Aluminum.........................10-26 Buck-Boost Encapsulated Transformers .............................10-51
Three-Phase DOE 2016 Efficiency, Copper...............................10-27 Selection Tables .....................................................................................10-54
Noise Isolation Guard II .......................................................10-28 Connection Diagrams .........................................................................10-61
Three-Phase DOE 2016 Efficiency, Aluminum.........................10-29 Open Core and Coil Transformers ........................................10-62
Three-Phase DOE 2016 Efficiency, Copper...............................10-30 Machine Tool Applications................................................................10-63
Harmonic Mitigating Guard III Control........................................................................................................10-64
Three-Phase DOE 2016 Efficiency, Copper...............................10-31 Options and Fusing Guide ................................................................10-66
Wiring Diagrams ...................................................................................10-67
Outlines and Dimensions ..................................................................10-68
CE-Rated....................................................................................................10-69
Termination
Improved termination spacing and wiring compartment room
gives greater flexibility in selecting various UL listed connectors
for either copper or aluminum cable.
9T 1 0 A 100 1 G31
GE Standard Group Number
No Group Number Shown = 150C G34 = 115C, Electrostatic Shield, -3dB
1 = QL DOE 2016 Design kVA Rating G02 = 150C, -3dB G35 = 115C, -5dB
1 = 15kVA G03 = 150C, Electrostatic Shield G36 = 115C, Electrostatic Shield, -5dB
Transformer Type 2 = 30kVA G04 = 150C, Electrostatic Shield, -3dB G39 = 115C, Non-STD kVA
0 = Standard, K1 3 = 45kVA G05 = 150C, -5dB G40 = 115C, Non-STD kVA
1 = K13 4 = 75kVA G06 = 150C, Electrostatic Shield, -5dB G61 = 80C
2 = K20 5 = 112.5kVA G09 = 150C, Non-STD kVA G62 = 80C, -3dB
3 = K30 6 = 150kVA G10 = 150C, Non-STD kVA G63 = 80C, Electrostatic Shield
4 = K4 7 = 225kVA G29 = 140C, 40C amb G64 = 80C, Electrostatic Shield, -3dB
7 = Guard II/Servicenter 8 = 300kVA G30 = 140C, 50C amb G65 = 80C, -5dB
8 = Spare Parts 9 = 500kVA G31 = 115C G66 = 80C, Electrostatic Shield, -5dB
G32 = 115C, -3dB G69 = 80C, Non-STD kVA
Coil Material G33 = 115C, Electrostatic Shield G70 = 80C, Non-STD kVA
A = Aluminum Voltage Rating An Electrostatic Shield (also called a Guard I transformer) is a grounded, copper-foil barrier between the primary
C = Copper See Voltage Chart below and secondary winding to reduce electrical noise. All K-Factor transformers contain an Electrostatic Shield.
Advantages
Quiet performance
No-weld design an industry first
Comprehensive factory testing assures quality
Accessible mounting foot design speeds installation
Lug kit and ground bar kit included up through 150kVA
GEs exclusive wood crate packaging helps reduce
shipping damage
Key Features
Unique core and coil design makes QL transformers among the
quietest available Type QL Transformer
Core and coil assemblies are mounted on rubber isolation pads
to reduce noise Seismic qualified to the requirements of ASCE 7.05,
Bolted coil terminations are more reliable than welded termina- IEEE-693-2005 and IBC-2012/CBC-2013
tions, and they eliminate weld failures and problems associated Copper or aluminum windings
with welding and weld splatter Copper ground strap
Single-piece front/back is easily removable for service Robust packaging with top and side protection protects against
Accessible mounting flanges with front/back slotted mounting shipping damage
holes make installation easier
100% factory tested for shorts and coil integrity, current and Applications
loss, voltage, impedance and noise. Commercial
NEMA 2 powder-coat drip-proof enclosure is standard. Industrial
Weathershield kit is available for conversion to NEMA 3R Motors
outdoor. Incandescent lighting
NEMA 3R stainless steel enclosure is available up to 150kVA. Resistance heating
To specify a stainless steel enclosure, substitute an S in the Motor generators (without solid state drives)
fifth character in the GE catalog number.
Example: 9T10A1004 changes to 9T10S1004.
Transformer Selection Guide
(type 316) Enclosure
K -Factor (K=13)
K -Factor (K=20)
K -Factor (K=30)
K -Factor (K=4)
Service Center
Stainless Steel
Standard
Guard III
Guard II
Guard I
TENV
DIT
Motors X X X
Incandescent Lighting X X X
Resistance Heating X X X
Motor Generators (without solid state drives) X X X
HID Lighting X
Induction Heaters X
Welders X
UPS with optional input filtering X
PLC & Solid state controls X
Multiple receptacle circuits in heath care facilities X
UPS without optional input filtering X
Production or assembly line equipment X
Schools & Classroom facilities X
Surge Supression X
Office Buildings X X X X
SCR Variable Speed Drives X X
Circuits with exclusive data processing equipment X X X X
Critical Care facilities X X X X
Hospital Operating Rooms X X X X
X-ray equipment X X X X
Computer Installations X X X X
Programmable Controllers X X X X
Instrumentation X X X X
AC or DC Variable Speed Drives X
Rectifier outputs X
Temporary Power X
Airborne contamins or dust-laden environments (indoor and outdoor) X
Corrosive environments including water/wastewater and salt spray X
Type QL Transformer
Product Description
These type QL transformers have passed the UL K-factor testing
program. K-factor is a standardized way to indicate the ability of
a transformer to withstand harmonics. These units shall not
exceed rated winding temperature rise at full load and rated K-
factor. Neutrals are capable of handling 200% of rated secondary
phase current.
Full-width copper electrostatic shielding is standard on all GE
K-factor rated transformers. Effective coupling capacitance is
30 pf. Common mode noise attenuation averages 120 dB, and
transverse mode noise attenuation averages 30 dB.
Application
For commercial applications with significant nonlinear electronic
loading, use K=4 for systems with 50% connected nonlinear elec-
tronic loads; K=13 for systems with 100% connected nonlinear
electronic loads.
Higher K-factor rated units are available for unique applications. Type QL, UL K-Factor Transformer
K = 4 150C Rise
Input Output Wiring Approx. Net Frame Product
Voltage Voltage kVA Taps Diagram No.1 Weight (Lbs) Size Number
15 (+2, -4 2.5%) 12 230 UX71C 9T14C1001G04
30 (+2, -4 2.5%) 12 353 UX72C 9T14C1002G04
45 (+2, -4 2.5%) 12 480 UX73C 9T14C1003G04
75 (+2, -4 2.5%) 12 661 UY74C 9T14C1004G04
480 Volts Delta 208Y/120 Volts
112.5 (+2, -4 2.5%) 12 790 DY75C 9T14C1005G04
150 (+2, -4 2.5%) 12 1610 DY77C 9T14C1006G04
225 (+2, -4 2.5%) 12 1970 DY78C 9T14C1007G04
300 (+2, -2 2.5%) 12 3720 DX79C 9T14C1008G04
K = 4 115C Rise
Input Output Wiring Approx. Net Frame Product
Voltage Voltage kVA Taps Diagram No.1 Weight (Lbs) Size Number
15 (+2, -4 2.5%) 12 353 UX72C 9T14C1001G34
30 (+2, -4 2.5%) 12 353 UX72C 9T14C1002G34
45 (+2, -4 2.5%) 12 661 UY74C 9T14C1003G34
480 Volts Delta 208Y/120 Volts 75 (+2, -4 2.5%) 12 790 DY75C 9T14C1004G34
112.5 (+2, -4 2.5%) 12 900 DX75C 9T14C1005G34
150 (+2, -4 2.5%) 12 1610 DY77C 9T14C1006G34
225 (+2, -4 2.5%) 12 2150 DX78C 9T14C1007G34
300 (+2, -2 2.5%) 12 3720 DX79C 9T14C1008G34
K = 4 80C Rise
Input Output Wiring Approx. Net Frame Product
Voltage Voltage kVA Taps Diagram No.1 Weight (Lbs) Size Number
15 (+2, -4 2.5%) 12 353 UX72C 9T14C1001G64
30 (+2, -4 2.5%) 12 480 UX73C 9T14C1002G64
45 (+2, -4 2.5%) 12 661 UY74C 9T14C1003G64
480 Volts Delta 208Y/120 Volts 75 (+2, -4 2.5%) 12 790 DY75C 9T14C1004G64
112.5 (+2, -4 2.5%) 12 1240 DX76C 9T14C1005G64
150 (+2, -4 2.5%) 12 1610 DY77C 9T14C1006G64
225 (+2, -2 2.5%) 12 3720 DX79C 9T14C1007G64
K = 13 150C Rise
Input Output Wiring Approx. Net Frame Product
Voltage Voltage kVA Taps Diagram No.1 Weight (Lbs) Size Number
15 (+2, -4 2.5%) 12 230 UX71C 9T11C1001G04
30 (+2, -4 2.5%) 12 353 UX72C 9T11C1002G04
45 (+2, -4 2.5%) 12 480 UX73C 9T11C1003G04
480 Volts Delta 208Y/120 Volts 75 (+2, -4 2.5%) 12 790 DY75C 9T11C1004G04
112.5 (+2, -4 2.5%) 12 790 DY75C 9T11C1005G04
150 (+2, -4 2.5%) 12 1610 DY77C 9T11C1006G04
225 (+2, -4 2.5%) 12 1970 DY78C 9T11C1007G04
300 (+2, -2 2.5%) 12 3720 DX79C 9T11C1008G04
K = 13 115C Rise
Input Output Wiring Approx. Net Frame Product
Voltage Voltage kVA Taps Diagram No.1 Weight (Lbs) Size Number
15 (+2, -4 2.5%) 12 353 UX72C 9T11C1001G34
30 (+2, -4 2.5%) 12 480 UX73C 9T11C1002G34
45 (+2, -4 2.5%) 12 661 UY74C 9T11C1003G34
480 Volts Delta 208Y/120 Volts 75 (+2, -4 2.5%) 12 790 DY75C 9T11C1004G34
112.5 (+2, -4 2.5%) 12 1085 DY76C 9T11C1005G34
150 (+2, -4 2.5%) 12 1610 DY77C 9T11C1006G34
225 (+2, -2 2.5%) 12 3720 DX79C 9T11C1007G34
300 (+2, -2 2.5%) 12 3720 DX79C 9T11C1008G34
K = 13 80C Rise
Input Output Wiring Approx. Net Frame Product
Voltage Voltage kVA Taps Diagram No.1 Weight (Lbs) Size Number
15 (+2, -4 2.5%) 12 353 UX72C 9T11C1001G64
30 (+2, -4 2.5%) 12 661 UY74C 9T11C1002G64
45 (+2, -4 2.5%) 12 661 UY74C 9T11C1003G64
480 Volts Delta 208Y/120 Volts 75 (+2, -4 2.5%) 12 790 DY75C 9T11C1004G64
112.5 (+2, -4 2.5%) 12 1240 DX76C 9T11C1005G64
150 (+2, -4 2.5%) 12 1610 DY77C 9T11C1006G64
225 (+2, -2 2.5%) 12 3720 DX79C 9T11C1007G64
1See page 10-45 for wiring diagrams.
K = 20 150C Rise
Input Output Wiring Approx. Net Frame Product
Voltage Voltage kVA Taps Diagram No.1 Weight (Lbs) Size Number
15 (+2, -4 2.5%) 12 2 2 9T12C1001G04
30 (+2, -4 2.5%) 12 2 2 9T12C1002G04
45 (+2, -4 2.5%) 12 2 2 9T12C1003G04
480 Volts Delta 208Y/120 Volts
75 (+2, -4 2.5%) 12 2 2 9T12C1004G04
112.5 (+2, -4 2.5%) 12 2 2 9T12C1005G04
150 (+2, -4 2.5%) 12 2 2 9T12C1006G04
K = 20 115C Rise
Input Output Wiring Approx. Net Frame Product
Voltage Voltage kVA Taps Diagram No.1 Weight (Lbs) Size Number
15 (+2, -4 2.5%) 12 2 2 9T12C1001G34
30 (+2, -4 2.5%) 12 2 2 9T12C1002G34
45 (+2, -4 2.5%) 12 2 2 9T12C1003G34
480 Volts Delta 208Y/120 Volts 2 2
75 (+2, -4 2.5%) 12 9T12C1004G34
112.5 (+2, -4 2.5%) 12 2 2 9T12C1005G34
150 (+2, -4 2.5%) 12 2 2 9T12C1006G34
K = 20 80C Rise
Input Output Wiring Approx. Net Frame Product
Voltage Voltage kVA Taps Diagram No.1 Weight (Lbs) Size Number
15 (+2, -4 2.5%) 12 2 2 9T12C1001G64
30 (+2, -4 2.5%) 12 2 2 9T12C1002G64
480 Volts Delta 208Y/120 Volts 2 2
45 (+2, -4 2.5%) 12 9T12C1003G64
75 (+2, -4 2.5%) 12 2 2 9T12C1004G64
112.5 (+2, -4 2.5%) 12 2 2 9T12C1005G64
K = 30 150C Rise
Input Output Wiring Approx. Net Frame Product
Voltage Voltage kVA Taps Diagram No.1 Weight (Lbs) Size Number
15 (+2, -4 2.5%) 12 2 2 9T13C1001G04
30 (+2, -4 2.5%) 12 2 2 9T13C1002G04
45 (+2, -4 2.5%) 12 2 2 9T13C1003G04
480 Volts Delta 208Y/120 Volts
75 (+2, -4 2.5%) 12 2 2 9T13C1004G04
112.5 (+2, -4 2.5%) 12 2 2 9T13C1005G04
150 (+2, -4 2.5%) 12 2 2 9T13C1006G04
K = 30 115C Rise
Input Output Wiring Approx. Net Frame Product
Voltage Voltage kVA Taps Diagram No.1 Weight (Lbs) Size Number
15 (+2, -4 2.5%) 12 2 2 9T13C1001G34
30 (+2, -4 2.5%) 12 2 2 9T13C1002G34
480 Volts Delta 208Y/120 Volts 45 (+2, -4 2.5%) 12 2 2 9T13C1003G34
75 (+2, -4 2.5%) 12 2 2 9T13C1004G34
112.5 (+2, -4 2.5%) 12 2 2 9T13C1005G34
1See page 10-45 for wiring diagrams.
2Call GE Technical Support at 1-800-GE 1-STOP, Option #4
Product Description
These low noise transformers are designed to operate at reduced
noise levels. The vibrations within the magnetic steel core have
been greatly reduced, thus lowering the humming of the trans-
former 3 dB less than NEMA/ANSI standards. Available in
Aluminum or Copper windings, with either a 150C, 115C or
80C rise.
Application
Type QL low noise transformers are ideal when quiet operation is
required such as near offices, in school buildings, or hospitals.
Although they are inherently quieter, installation can greatly
influence their noise level and therefore care should be taken in
following acoustical principles as well as proper installation
procedures. Closets and corners should be avoided as they act as
megaphones by seemingly increasing noise levels. Type QL Low Noise Transformer (front panel removed)
Key Features
Grounded copper electrostatic shield between
primary and secondary windings
Noise suppressors and spike/surge suppressors
120dB common mode noise rejection
60dB transverse mode noise rejection
Compliance with ANSI and NEMA standards
Sound levels below NEMA ST-20 limits
UL Listed Guard II Transformer
NEMA 2 enclosure
Applications
Schools and colleges
Large computer installations
Small commercial offices
Motor installations
Process controllers
Hospitals
X-ray rooms
Electrical laboratories
High lightning strike areas
150C Rise
Input Output Wiring Approx Net Frame Product
Voltage Voltage kVA Taps Diagram No.1 Weight (Lbs) Size Number
15 (+2, -4 2.5%) 12 260 XV371 9T17A1001G03
30 (+2, -4 2.5%) 12 370 XV372 9T17A1002G03
480 Volts Delta 208Y/120 Volts 45 (+2, -4 2.5%) 12 460 XV373 9T17A1003G03
75 (+2, -4 2.5%) 12 680 XV374 9T17A1004G03
112.5 (+2, -4 2.5%) 12 830 XV375 9T17A1005G03
115C Rise
Input Output Wiring Approx Net Frame Product
Voltage Voltage kVA Taps Diagram No.1 Weight (Lbs) Size Number
15 (+2, -4 2.5%) 12 260 XV371 9T17A1001G33
30 (+2, -4 2.5%) 12 370 XV372 9T17A1002G33
480 Volts Delta 208Y/120 Volts
45 (+2, -4 2.5%) 12 460 XV373 9T17A1003G33
75 (+2, -4 2.5%) 12 680 XV374 9T17A1004G33
80C Rise
Input Output Wiring Approx Net Frame Product
Voltage Voltage kVA Taps Diagram No.1 Weight (Lbs) Size Number
15 (+2, -4 2.5%) 12 370 XV372 9T17A1001G63
30 (+2, -4 2.5%) 12 460 XV373 9T17A1002G63
480 Volts Delta 208Y/120 Volts
45 (+2, -4 2.5%) 12 680 XV374 9T17A1003G63
75 (+2, -4 2.5%) 12 830 XV375 9T17A1004G63
150C Rise
Input Output Wiring Approx Net Frame Product
Voltage Voltage kVA Taps Diagram No.1 Weight (Lbs) Size Number
15 (+2, -4 2.5%) 12 260 XV371 9T17A1451G03
30 (+2, -4 2.5%) 12 370 XV372 9T17A1452G03
208 Volts Delta 208Y/120 Volts 45 (+2, -4 2.5%) 12 460 XV373 9T17A1453G03
75 (+2, -4 2.5%) 12 680 XV374 9T17A1454G03
112.5 (+2, -4 2.5%) 12 830 XV375 9T17A1455G03
115C Rise
Input Output Wiring Approx Net Frame Product
Voltage Voltage kVA Taps Diagram No.1 Weight (Lbs) Size Number
15 (+2, -4 2.5%) 12 260 XV371 9T17A1451G33
208 Volts Delta 208Y/120 Volts 30 (+2, -4 2.5%) 12 370 XV372 9T17A1452G33
45 (+2, -4 2.5%) 12 460 XV373 9T17A1453G33
75 (+2, -4 2.5%) 12 680 XV374 9T17A1454G33
80C Rise
Input Output Wiring Approx Net Frame Product
Voltage Voltage kVA Taps Diagram No.1 Weight (Lbs) Size Number
15 (+2, -4 2.5%) 12 370 XV372 9T17A1451G63
30 (+2, -4 2.5%) 12 460 XV373 9T17A1452G63
208 Volts Delta 208Y/120 Volts
45 (+2, -4 2.5%) 12 680 XV374 9T17A1453G63
75 (+2, -4 2.5%) 12 830 XV375 9T17A1454G63
1See page 10-45 for wiring diagrams.
150C Rise
Input Output Wiring Approx Net Frame Product
Voltage Voltage kVA Taps Diagram No.1 Weight (Lbs) Size Number
15 (+2, -4 2.5%) 12 270 XV371 9T17C1001G03
30 (+2, -4 2.5%) 12 420 XV372 9T17C1002G03
480 Volts Delta 208Y/120 Volts 45 (+2, -4 2.5%) 12 540 XV373 9T17C1003G03
75 (+2, -4 2.5%) 12 770 XV374 9T17C1004G03
112.5 (+2, -4 2.5%) 12 1010 XV375 9T17C1005G03
115C Rise
Input Output Wiring Approx Net Frame Product
Voltage Voltage kVA Taps Diagram No.1 Weight (Lbs) Size Number
15 (+2, -4 2.5%) 12 270 XV371 9T17C1001G33
30 (+2, -4 2.5%) 12 420 XV372 9T17C1002G33
480 Volts Delta 208Y/120 Volts 45 (+2, -4 2.5%) 12 540 XV373 9T17C1003G33
75 (+2, -4 2.5%) 12 770 XV374 9T17C1004G33
112.5 (+2, -4 2.5%) 12 1010 XV375 9T17C1005G33
80C Rise
Input Output Wiring Approx Net Frame Product
Voltage Voltage kVA Taps Diagram No.1 Weight (Lbs) Size Number
15 (+2, -4 2.5%) 12 420 XV372 9T17C1001G63
30 (+2, -4 2.5%) 12 540 XV373 9T17C1002G63
480 Volts Delta 208Y/120 Volts
45 (+2, -4 2.5%) 12 770 XV374 9T17C1003G63
75 (+2, -4 2.5%) 12 1010 XV375 9T17C1004G63
150C Rise
Input Output Wiring Approx Net Frame Product
Voltage Voltage kVA Taps Diagram No.1 Weight (Lbs) Size Number
15 (+2, -4 2.5%) 12 270 XV371 9T17C1451G03
30 (+2, -4 2.5%) 12 420 XV372 9T17C1452G03
208 Volts Delta 208Y/120 Volts 45 (+2, -4 2.5%) 12 540 XV373 9T17C1453G03
75 (+2, -4 2.5%) 12 770 XV374 9T17C1454G03
112.5 (+2, -4 2.5%) 12 1010 XV375 9T17C1455G03
115C Rise
Input Output Wiring Approx Net Frame Product
Voltage Voltage kVA Taps Diagram No.1 Weight (Lbs) Size Number
15 (+2, -4 2.5%) 12 270 XV371 9T17C1451G33
30 (+2, -4 2.5%) 12 420 XV372 9T17C1452G33
208 Volts Delta 208Y/120 Volts 45 (+2, -4 2.5%) 12 540 XV373 9T17C1453G33
75 (+2, -4 2.5%) 12 770 XV374 9T17C1454G33
112.5 (+2, -4 2.5%) 12 1010 XV375 9T17C1455G33
1See page 10-45 for wiring diagrams.
Single-Phase Servicenter
Single-Phase Indoor/Outdoor 60 Hz
Max. Branch Max. Branch Max. Branch Max. Branch
Input Output Spaces 1 THQL, Spaces 1 THQL, Spaces 1/2 THQP, Spaces 1/2 THQP, Total Breaker Rating- Breaker Rating- Product
Voltage Voltage kVA 1-pole 2-pole 1-pole 2-pole 1-pole Spaces Primary Main Secondary Main Number
5 6 3 12 4 12 25A 30A 9T21S1050
7.5 6 3 12 4 12 35A 40A 9T21S1070
480 Volts Delta 120/240 Volts 10 8 4 16 6 16 50A 50A 9T21S1100
15 12 6 24 10 24 60A 70A 9T21S1150
25 20 10 8 2 24 100A 150A 9T21S1250
2Three-Phase Servicenters may be ordered with a stainless steel enclosure. To order this option, replace the fifth character in the Product Number with the letterS.
For example: 9T17A0001 becomes 9T17S0001; 9T17C0004 becomes 9T17S0004.
Single-Phase
Product Approx. Net "A" "B" "C" Frame
kVA Number Weight (Lbs.) Height (in.) Width (in.) Depth (in.) Size
5 9T21S1050 103 32.5 10.75 11.12 16350
7.5 9T21S1070 147 32.5 10.75 11.12 16600
10 9T21S1100 198 35 12.62 12.62 19400
15 9T21S1150 220 35 12.62 12.62 19500
25 9T21S1250 388 44.75 16.75 16 50500
Advantages
Dry-type transformer is housed in an enclosed NEMA 3R
non-ventilated compartment
Convenient wiring compartment is located beneath the
transformer and has removable front and rear covers
Copper bus bars are located at the front of the wiring
compartment and are clearly labeled
All electrical connections between the transformer and
TENV Transformer
bus bars are factory wired
Quiet performance meets NEMA ST-20
No-weld coil termination design an industry first
Comprehensive factory testing assures quality
Features
Quiet design - unique core and coil design makes GE TENV
transformers among the quietest available
Core and coil assembly mounted on rubber isolation pads to
reduce noise
Bolted coil terminations are more reliable than welded
terminations, and they eliminate weld failures and problems
associated with welding and weld splatter
100% factory tested for shorts and coil integrity, current and
loss, voltage, impedance and noise
Qualified to the seismic requirements of IEEE-693-2005 and
IBC-2012/CBC-2013
Copper ground strap
Copper or aluminum windings available
Available in 150C, 115C, and 80C rise models
Indoor or outdoor use
Applications
Textile
Automotive
Foundry
Paper mills
Wash-down areas
Aluminum
150C Rise 60Hz
Input Output Net
Voltage Voltage kVA Taps Weight (Lbs.) Frame Size Product Number
480 240/120 15 (+2,-4 2.5%) 231 UX71A 9T10A1181
480 240/120 30 (+2,-4 2.5%) 330 UX72A 9T10A1182
480 240/120 45 (+2,-4 2.5%) 444 UX73A 9T10A1183
480 240/120 75 (+2,-4 2.5%) 561 UY74A 9T10A1184
480 240/120 112.5 (+2,-4 2.5%) 830 DX75A 9T10A1185
480 240/120 150 (+2,-4 2.5%) 1030 DY76A 9T10A1186
480 240/120 225 (+2,-4 2.5%) 1450 DY77A 9T10A1187
480 240/120 300 (+2,-4 2.5%) 1670 DY78A 9T10A1188
480 240/120 500 (+2,-2 2.5%) 2900 DX79A 9T10A1189
Application
The use of SCR control circuitry with adjustable-speed drives has with SCR drives. Isolation transformers also reduce line-pollution
resulted in a need for a line of isolation transformers specifically feedback resulting from SCR firing circuits. The GE delta-wye
designed to meet the demanding requirements of SCR drives. designs meet the NEC requirements for grounded secondary
Symmetrically placed taps and added coil bracing minimize neutrals that isolate primary distribution systems. kVA ratings of
mechanical forces caused by the often severe SCR drive duty the DIT line cover most dc motor requirements from 3 to 1000 hp.
cycles. These features also help protect the transformer from the Enclosed drive isolation transformers are UL listed.
regenerative duty and more frequent short-circuits associated
Conversion Chart
Decimal Fraction
.13 1/8
.38 3/8
.63 5/8
.88 7/8
FRONT/BACK
PANEL
FRONT/BACK
PANEL
GRILL
ENCLOSURE KIT: 1 COVER + 2 SIDES + 2 FRONTS ENCLOSURE KIT: 1 COVER + 2 SIDES + 2 FRONTS
This style enclosure is used with the This style enclosure is used with the
following frames: following frames:
UX71A UY74C DX76A DX79A
UX71C UX74C DX76C DX79C
UX72A DY75A DX77A YF171
UX72C DY75C DX77C YF172
UX73A DX75A DY77A YF173
UX73C DX75C DY77C YF174
UY74A DY76A DY78C YF175
UX74A DY76C DY78A YF176
DX78A YF177
DX78C
QL Transformer
3-Phase, Vented, Non-Fan Cooled QL Transformers (Front Panel Removed)
(9T8, 9T7, 9T6 models)
Includes General Purpose, K-Factor, K-Factor Low Noise,
Low Noise, Guard I, Midtapped, Drive Isolation
Enclosure Dimensions Mounting Feet Dimensions Weight
Frame Size Outline Drawing Width (in.) Depth (in.) Height (in.) Width (in.) Depth (in.) Painted (lbs.) 316 Stainless Steel (lbs.)
UX71A 303B111GEUXP71A 18.7 16.9 29.3 21.2 15.1 231 251
UX71C 303B111GEUXP71C 18.7 16.9 29.3 21.2 15.1 230 250
UX72A 303B111GEUXP72A 23.8 18.4 34.7 26.2 16.6 330 350
UX72C 303B111GEUXP72C 23.8 18.4 34.7 26.2 16.6 353 373
UX73A 303B111GEUXP73A 23.8 18.4 34.7 26.2 16.6 444 464
UX73C 303B111GEUXP73C 23.8 18.4 34.7 26.2 16.6 480 500
UY74A 303B111GEUYP74A 31.8 24 35.7 34.3 22.3 561 581
UY74C 303B111GEUYP74C 31.8 24 35.7 34.3 22.3 661 681
UX74A 303B111GEUXP74A 31.8 24 35.7 34.3 22.3 603 623
UX74C 303B111GEUXP74C 31.8 24 35.7 34.3 22.3 748 768
DY75A 303B111GEDYP75A 31.8 24 42.2 34.3 22.3 680 760
DY75C 303B111GEDYP75C 31.8 24 42.2 34.3 22.3 790 870
DX75A 303B111GEDXP75A 34.8 24 45.8 37.3 22.3 830 850
DX75C 303B111GEDXP75C 31.8 24 42.2 34.3 22.3 900 980
DY76A 303B111GEDYP76A 34.8 24 45.8 37.3 22.3 1030 1050
DY76C 303B111GEDYP76C 34.8 24 45.8 37.3 22.3 1085 1105
DX76A 303B112GEDXP76A 38.4 33 47.4 41.1 32 1250 Not available
DX76C 303B111GEDXP76C 34.8 24 45.8 37.3 22.3 1240 1260
DY77A 303B112GEDYP77A 38.4 33 47.4 41.4 32 1450 Not available
DY77C 303B112GEDYP77C 38.4 33 47.4 41.4 32 1610 Not available
DX77A 303B112GEDXP77A 38.4 33 47.4 41.4 32 1670 Not available
DY78A 303B112GEDYP78A 38.4 33 57.1 41.4 32 1670 Not available
DX77C 303B112GEDXP77C 38.4 33 47.4 41.4 32 1847 Not available
DY78C 303B112GEDYP78C 38.4 33 57.1 41.4 32 1970 Not available
DX78A 303B112GEDXP78A 38.4 33 57.1 41.4 32 1985 Not available
DX78C 303B112GEDXP78C 38.4 33 57.1 41.4 32 2150 Not available
DX79A 303B112GEDXP79A 46.5 37.8 65.7 50.1 37 2900 Not available
DX79C 303B112GEDXP79C 46.5 37.8 65.7 50.1 37 3720 Not available
TENV Transformers
Frame Size Outline Drawing No. Height (In.) Width (In.) Depth (In.)
XV372 303B405AAP072 41.3 23.8 18.4
XV373 303B405AAP073 41.3 23.8 18.4
XV374 303B405AAP074 44.8 31.8 24
XV375 303B405AAP075 49.1 31.8 24
240 x 480 Volts, 480 Volts 120/240 Volts 0.05 60 Hz No Taps 1 6 6100 9T51B0002
240 x 480 Volts 120/240 Volts 0.05 50 Hz No Taps 1 6 6100 9T51B0502
240 x 480 Volts, 480 Volts 120/240 Volts 0.075 60 Hz No Taps 1 6 6200 9T51B0003
240 x 480 Volts 120/240 Volts 0.075 50 Hz No Taps 1 6 6200 9T51B0503
240 x 480 Volts, 480 Volts 120/240 Volts 0.1 60 Hz No Taps 1 6 6200 9T51B0004
240 x 480 Volts 120/240 Volts 0.1 50 Hz No Taps 1 6 6200 9T51B0504
240 x 480 Volts, 480 Volts 120/240 Volts 0.15 60 Hz No Taps 1 10 8175 9T51B0005
240 x 480 Volts 120/240 Volts 0.15 50 Hz No Taps 1 10 8175 9T51B0505
240 x 480 Volts, 480 Volts 120/240 Volts 0.25 60 Hz No Taps 1 10 8175 9T51B0007
240 x 480 Volts 120/240 Volts 0.25 50 Hz No Taps 1 10 8200 9T51B0507
240 x 480 Volts, 480 Volts 120/240 Volts 0.5 60 Hz No Taps 1 16 10200 9T51B0008
240 x 480 Volts 120/240 Volts 0.5 50 Hz No Taps 1 20 10225 9T51B0508
240 x 480 Volts, 480 Volts 120/240 Volts 0.75 60 Hz No Taps 1 25 12200 9T51B0009
240 x 480 Volts 120/240 Volts 0.75 50 Hz No Taps 1 25 12225 9T51B0509
240 x 480 Volts, 480 Volts 120/240 Volts 1 60 Hz No Taps 1 25 12225 9T51B0010
240 x 480 Volts 120/240 Volts 1 50 Hz No Taps 1 30 12275 9T51B0510
240 x 480 Volts, 480 Volts 120/240 Volts 1.5 60 Hz No Taps 1 40 14200 9T51B0011
240 x 480 Volts 120/240 Volts 1.5 50 Hz No Taps 1 40 14225 9T51B0511
240 x 480 Volts, 480 Volts 120/240 Volts 2 60 Hz No Taps 1 45 14250 9T51B0012
240 x 480 Volts 120/240 Volts 2 50 Hz No Taps 1 50 14300 9T51B0512
240 x 480 Volts, 480 Volts 120/240 Volts 3 60 Hz No Taps 1 55 14350 9T51B0013
240 x 480 Volts 120/240 Volts 3 50 Hz No Taps 1 60 14400 9T51B0513
480 Volts 120/240 Volts 0.5 50 Hz (-2 5.0%) 2 20 10225 9T51B0548
480 Volts 120/240 Volts 0.75 50 Hz (-2 5.0%) 2 25 12200 9T51B0549
480 Volts 120/240 Volts 1 60 Hz (-2 5.0%) 2 25 12225 9T51B0050
480 Volts 120/240 Volts 1 50 Hz (-2 5.0%) 2 30 12275 9T51B0550
480 Volts 120/240 Volts 1.5 60 Hz (-2 5.0%) 2 40 14200 9T51B0051
480 Volts 120/240 Volts 1.5 50 Hz (-2 5.0%) 2 40 14225 9T51B0551
480 Volts 120/240 Volts 2 60 Hz (-2 5.0%) 2 45 14250 9T51B0052
480 Volts 120/240 Volts 2 50 Hz (-2 5.0%) 2 50 14300 9T51B0552
480 Volts 120/240 Volts 3 60 Hz (-2 5.0%) 2 55 14350 9T51B0053
480 Volts 120/240 Volts 3 60 Hz (+2,-2 2.5%) 3 55 14350 9T51B0135
480 Volts 120/240 Volts 3 50 Hz (-2 5.0%) 2 60 14400 9T51B0553
600 Volts 120/240 Volts 0.05 60 Hz No Taps 5 6 6100 9T51B0082
600 Volts 120/240 Volts 0.075 60 Hz No Taps 5 6 6200 9T51B0083
600 Volts 120/240 Volts 0.1 60 Hz No Taps 5 6 6200 9T51B0084
600 Volts 120/240 Volts 0.1 50 Hz No Taps 5 6 6200 9T51B0584
600 Volts 120/240 Volts 0.15 60 Hz No Taps 5 10 8175 9T51B0085
600 Volts 120/240 Volts 0.25 60 Hz No Taps 5 10 8175 9T51B0087
600 Volts 120/240 Volts 0.25 50 Hz No Taps 5 10 8200 9T51B0587
600 Volts 120/240 Volts 0.5 60 Hz No Taps 5 16 10200 9T51B0088
600 Volts 120/240 Volts 0.5 50 Hz (-2 5.0%) 2 20 10225 9T51B0568
600 Volts 120/240 Volts 0.75 60 Hz No Taps 5 25 12200 9T51B0089
600 Volts 120/240 Volts 0.75 50 Hz (-2 5.0%) 2 25 12200 9T51B0569
600 Volts 120/240 Volts 1 60 Hz (-2 5.0%) 2 25 12225 9T51B0070
600 Volts 120/240 Volts 1 60 Hz No Taps 5 25 12225 9T51B0090
600 Volts 120/240 Volts 1 50 Hz (-2 5.0%) 2 30 12275 9T51B0570
600 Volts 120/240 Volts 1.5 60 Hz (-2 5.0%) 2 40 14200 9T51B0071
600 Volts 120/240 Volts 1.5 60 Hz No Taps 5 40 14200 9T51B0091
600 Volts 120/240 Volts 1.5 50 Hz (-2 5.0%) 2 40 14225 9T51B0571
600 Volts 120/240 Volts 2 60 Hz (-2 5.0%) 2 45 14250 9T51B0072
600 Volts 120/240 Volts 2 60 Hz No Taps 5 45 14250 9T51B0092
600 Volts 120/240 Volts 2 50 Hz (-2 5.0%) 2 50 14300 9T51B0572
600 Volts 120/240 Volts 2 50 Hz No Taps 50 14300 9T51B0592
600 Volts 120/240 Volts 3 60 Hz (-2 5.0%) 2 55 14350 9T51B0073
600 Volts 120/240 Volts 3 60 Hz No Taps 5 55 14350 9T51B0093
600 Volts 120/240 Volts 3 50 Hz (-2 5.0%) 2 60 14400 9T51B0573
600 Volts 120/240 Volts 3 50 Hz No Taps 60 14400 9T51B0593
1See page 10-45 for wiring diagrams.
For Bucking or Boosting Voltage of Single-Phase Indoor/Outdoor Type QB 60 Hz UL Listed CSA Certified1
Approx. Net Frame Product
Input Voltage Output Voltage kVA2 Height (in) Width (in) Depth (in) Weight (Lbs.) Size Number
240/120 Volts 120 or 240/120 Volts 0.5 7.38 6.13 4.25 10 8175 9T51B0136
(Three-Wire)
240/120 Volts 120 or 240/120 Volts 0.75 8.38 6.88 4.88 16 10200 9T51B0137
(Three-Wire)
240/120 Volts 120 or 240/120 Volts 1 8.38 6.88 4.88 16 10200 9T51B0138
(Three-Wire)
240/120 Volts 120 or 240/120 Volts 1.5 9.63 7.88 5.5 25 12200 9T51B0139
(Three-Wire)
240/120 Volts 120 or 240/120 Volts 2 9.63 7.88 5.5 25 12225 9T51B0140
(Three-Wire)
240/120 Volts 120 or 240/120 Volts) 3 11.13 9.38 6.75 40 14200 9T51B0141
(Three-Wire)
240/120 Volts 120 or 240/120 Volts 5 11.13 9.38 6.75 60 14400 9T51B0142
(Three-Wire)
1Through 3 kVA
For Bucking or Boosting Voltage of Single-Phase Indoor/Outdoor Type QMS 60 Hz UL Listed CSA Certified
Approx. Net Frame Product
Input Voltage Output Voltage kVA2 Height (in) Width (in) Depth (in) Weight (Lbs.) Size Number
240/120 Volts 120 or 240/120 Volts 10 14.50 10.62 11.00 103 16350 9T21B4553G02
(Three-Wire)
240/120 Volts 120 or 240/120 Volts 15 17.06 10.62 11.00 147 16600 9T21B9201
(Three-Wire)
240/120 Volts 120 or 240/120 Volts 25 17.06 12.50 12.50 220 19500 9T21B9202
(Three-Wire)
2kVA output at 120 Volts, two-wire, or allowable unbalance at 240/120 Volts, three-wire.
Conversion Chart
Decimal Fraction
.13 1/8
.38 3/8
.63 5/8
.88 7/8
Product Description
Buck boost transformers are small, single-phase, dry type distri-
bution transformers designed and shipped as insulating/isolating
transformers. They have a dual voltage primary and a dual volt-
age secondary. These transformers can be connected for a wide
range of voltage combinations. The most common use is to buck
(lower) or boost (raise) the supply voltage a small amount, usual-
ly 5 to 27%. Buck boost transformers comply with NEC Article
210-9, Exception 1, when field connected as an autotransformer.
GE bucking and boosting transformers provide an economical
and convenient means for bucking or boosting voltage, usually
no more than 20% on single- and three-phase circuits. They are
compact, relatively light in weight, and can be easily installed for
indoor or outdoor service.
Buck-boost transformers are employed primarily for boosting
single-and three-phase circuits by connecting them as auto-
Indoor/Outdoor Type QB Transformer; Single-Phase
transformers. When connected as an autotransformer, only the
low-voltage, high-current capacity secondary windings are
required to carry the load. Because this load is only transformed
over a small change in voltage, the buck-boost transformer can
handle loads many times its nameplate kVA rating.
The transformers with series-multiple 12/24, 24/48, or 16/32 Volt
secondary windings are suitable for a wide variety of applica-
tions. Two or more units can be used in various combinations to
obtain many other special voltages. (For fluctuating voltage con-
ditions, refer to Power Conditioning Equipment Products section
starting on page 10-36).
Wiring Diagram for Low Voltage Loads
Advantages
Efficient insulating materials permit compact size and
light weight Qualified to the seismic requirements of IEEE-693-1997 and
Dual voltage primary and dual voltage secondary for IBC-2003
maximum versatility ABS (American Bureau of Shipping) Type Approved
Large, front-accessible wiring compartment permits fast,
easy wiring Applications
Convenient conduit knockouts located on side, bottom and
International voltage adaptation
back of wiring compartment
Commercial and industrial air conditioning
GE Buck-Boost Transformer Selector makes selection fast
Heating systems
and easy
Induction motors
Many GE buck-boost transformers fit competitor mounting
Voltage line drop correction
footprints
Landscape lighting
Indoor or outdoor service
Low-voltage lighting
Key Features Marine and Offshore - ABS Classed Vessels
Convenient and least expensive method of matching line
Efficient operation of electrical equipment requires that line volt-
voltage with equipment voltage
age be at or near the nameplate rating of the equipment. In
More efficient than equivalent isolation transformers
order to match available line voltage (whether it be too high or
Ability to handle loads up to 20 times nameplate rating when
low) with equipment voltage, buck-boost transformers provide
connected as an autotransformer
the most convenient and least expensive method.
Ideal for changing line voltages by small amounts
Primary voltages include 120V, 240V and 480V Do not use buck-boost transformers to solve a fluctuating voltage
Secondary voltages include 12V, 16V, 24V, 32V, 48V problem. They should be used to compensate for high- or low-
UL and cUL Listed voltage conditions only when the available line voltage is
reasonably constant.
NOTE: In addition to bucking or boosting low circuit voltages to related value, these transformers can be used as two winding transformers to supply the rated nameplate
low voltages, 12 to 48 Volts, two-wire or 12/24 to 24/48 Volts, three-wire. Also available in 50/60 Hz ratings.
5-Step Selection
The tables on these pages greatly facilitate buck-boost trans- 4. Once you have established this point, read across to the far
former selection. Simply follow these five easy steps: left column for the exact GE buck-boost model number for
your application. For example, the 230 Volt table under the
1. Refer to the table having the same output voltage as the 208 column for a 2 kVA air conditioner, read across from 2.4
equipment you want to operate. For example, if you are (next higher kVA rating) and the model number is 9T51B0107.
installing a 230 Volt single-phase air conditioner, use the 5. Connect the buck-boost transformer you have selected per
230 Volt table. the connection diagram specified at the bottom of the avail-
2. Different available line voltages are listed across the top of able line voltage column you used. For example, if you used
each table. Select the line voltage column closest to your the 208 column, you would connect the buck-boost trans-
actual supply. If your available line voltage is exactly midway former per connection diagram A. Thats all there is to it! The
between two listed voltage levels, you may use either voltage transformer youve selected will meet your exact requirements
column. For example, in the 230 Volt table, if you have 212 when connected in the specified manner.
available, use either the 208 or the 216 column.
The formula for calculating single-phase kVA is:
3. Read down the available line voltage column until you reach
the rated load kVA of the equipment you want to operate or Load Voltage Full Load Amps
the next higher kVA rating. For example, in the 230 Volt table 1000
under the 208 available line voltage column, you want to oper-
ate an air conditioner rated 2 kVA. Since 2 kVA is not listed as The formula for calculating three-phase kVA is:
such, you must read down to the next higher value or 2.4 kVA. 1.732 Load Voltage Load Amps
1000
Table 1
230 Volts Output, 60 Hertz, Single-Phase
Available Line Voltage
192 203 208 216 219 242 245 353 261 276
Product Number Load kVA1
9T51B0102 0.480 0.960 1.0 0.530
9T51B0122 0.360 0.720 0.770 0.410
9T51B0202 0.240 0.288
9T51B0103 0.720 1.5 1.6 0.800
9T51B0123 0.540 1.1 1.2 0.620
9T51B0203 0.359 0.431
9T51B0104 0.960 2.0 2.1 1.1
9T51B0124 0.720 1.5 1.6 0.820
9T51B0204 0.479 0.575
9T51B0105 1.5 2.9 3.1 1.6
9T51B0125 1.1 2.2 2.3 1.3
9T51B0205 0.719 0.863
9T51B0107 2.4 4.8 5.1 2.7
9T51B0127 1.8 3.6 3.9 2.1
9T51B0207 1.2 1.4
9T51B0108 4.8 9.6 10.1 5.3
9T51B0128 3.6 7.2 7.7 4.1
9T51B0208 2.4 2.9
9T51B0109 7.2 14.4 15.2 7.9
9T51B0129 5.4 10.8 11.5 6.2
9T51B0209 3.6 4.3
9T51B0110 9.6 19.2 20.2 10.6
9T51B0130 7.2 14.4 15.4 8.2
9T51B0210 4.8 5.7
9T51B0111 14.4 28.8 30.3 15.9
9T51B0131 10.8 21.6 23.0 12.3
9T51B0211 7.2 8.6
9T51B0112 19.1 38.4 40.4 21.1
9T51B0132 14.4 28.8 30.7 16.4
9T51B0212 9.6 11.5
9T51B0113 28.7 57.5 60.5 31.7
9T51B0133 21.6 43.2 46.0 24.5
9T51B0213 14.4 17.3
9T21B1037G02 47.8 95.9 100.9 52.7
9T21B1040G02 36.0 72.0 77.0 40.8
Connection Diagram C A A B B B B A A C
Page 10-61
1The load kVA is the maximum load at voltages shown when transformers are connected as autotransformers according to the diagram referenced.
Table 2
240 Volts Output, 60 Hertz, Single-Phase
Available Line Voltage
200 212 218 225 229 252 256 264 272 288
Product Number Load kVA1
9T51B0102 0.500 1.0 1.1 0.6
9T51B0122 0.380 0.750 0.800 0.430
9T51B0202 0.250 0.300
9T51B0103 0.750 1.5 1.6 0.825
9T51B0123 0.570 1.2 1.2 0.640
9T51B0203 0.375 0.391
9T51B0104 1.0 2.0 2.1 1.1
9T51B0124 0.750 1.5 1.6 0.850
9T51B0204 0.500 0.522
9T51B0105 1.5 3.0 3.2 1.7
9T51B0125 1.2 2.3 2.4 1.3
9T51B0205 0.750 0.782
9T51B0107 2.5 5.0 5.3 2.8
9T51B0127 1.9 3.8 4.0 2.2
9T51B0207 1.3 1.4
9T51B0108 5.0 10.0 10.5 5.5
9T51B0128 3.8 7.5 8.0 4.3
9T51B0208 2.5 2.6
9T51B0109 7.5 15.0 15.8 8.3
9T51B0129 5.7 11.3 12.0 6.4
9T51B0209 3.8 4.0
9T51B0110 10.0 20.0 21.0 11.0
9T51B0130 7.5 15.0 16.0 8.5
9T51B0210 5.0 5.2
9T51B0111 15.0 30.0 31.5 16.5
9T51B0131 11.3 22.5 24.0 12.8
9T51B0211 7.5 7.8
9T51B0112 20.0 40.0 42.6 22.0
9T51B0132 15.0 30.0 32.0 17.0
9T51B0212 10.0 10.4
9T51B0113 30.0 60.0 63.0 33.0
9T51B0133 22.5 45.0 48.0 25.5
9T51B0213 15.0 15.6
9T21B1037G02 50.0 100.0 105.0 55.0
9T21B1040G02 37.5 75.0 80.0 42.5
Connection Diagram C A A B B B B A A C
Page 10-61
1The load kVA is the maximum load at voltages shown when transformers are connected as autotransformers according to the diagram referenced.
Table 3
115 Volts Output, 60 Hertz, Single-Phase
Available Line Voltage
91 96 101 105 127 130 138 146
Product Number Load kVA1
9T51B0102 0.240 0.480 0.539 0.290
9T51B0122 0.180 0.360 0.410 0.230
9T51B0103 0.360 0.720 0.800 0.440
9T51B0123 0.270 0.540 0.610 0.350
9T51B0104 0.480 0.960 1.1 0.580
9T51B0124 0.360 0.720 0.820 0.460
9T51B0105 0.720 1.5 1.6 0.870
9T51B0125 0.540 1.1 1.3 0.690
9T51B0107 1.2 2.4 2.7 1.5
9T51B0127 0.900 1.8 2.1 1.2
9T51B0108 2.4 4.8 5.3 2.9
9T51B0128 1.8 3.6 4.1 2.3
9T51B0109 3.6 7.2 8.0 4.4
9T51B0129 2.7 5.4 6.1 3.5
9T51B0110 4.8 9.6 10.6 5.8
9T51B0130 3.6 7.2 8.2 4.6
9T51B0111 7.2 14.4 15.9 8.6
9T51B0131 5.4 10.8 12.2 6.9
9T51B0112 9.6 19.2 21.2 11.5
9T51B0132 7.2 14.4 16.3 9.2
9T51B0113 14.4 28.8 31.8 17.3
9T51B0133 10.8 21.6 24.4 13.7
9T21B1061G02 24.0 48.0 53.0 28.8
9T21B1037G02 24.0 48.0 53.0 28.8
9T21B1064G02 18.0 36.0 41.0 22.9
9T21B1040G02 18.0 36.0 41.0 22.9
Connection Diagram C C D D D D C C
Page 10-61
1The load kVA is the maximum load at voltages shown when transformers are connected as autotransformers according to the diagram referenced.
Table 4
120 Volts Output, 60 Hertz, Single-Phase
Available Line Voltage
95 100 106 109 132 136 144 152
Product Number Load kVA1
9T51B0102 0.250 0.500 0.550 0.300
9T51B0122 0.190 0.380 0.430 0.240
9T51B0103 0.380 0.750 0.830 0.450
9T51B0123 0.290 0.570 0.640 0.360
9T51B0104 0.500 1.0 1.1 0.600
9T51B0124 0.380 0.750 0.850 0.480
9T51B0105 0.750 1.5 1.7 0.900
9T51B0125 0.570 1.2 1.3 0.720
9T51B0107 1.3 2.5 2.8 1.5
9T51B0127 0.940 1.9 2.2 1.2
9T51B0108 2.5 5.0 5.5 3.0
9T51B0128 1.9 3.8 4.3 2.4
9T51B0109 3.8 7.5 8.3 4.5
9T51B0129 2.9 5.7 6.4 3.6
9T51B0110 5.0 10.0 11.0 6.0
9T51B0130 3.8 7.5 8.5 4.8
9T51B0111 7.5 15.0 16.5 9.0
9T51B0131 5.7 11.3 12.8 7.2
9T51B0112 10.0 20.0 22.0 12.0
9T51B0132 7.5 15.0 17.0 9.5
9T51B0113 15.0 30.0 33.0 18.0
9T51B0133 11.3 22.5 25.5 14.3
9T21B1061G02 25.0 50.0 55.0 30.0
9T21B1037G02 25.0 50.0 55.0 30.0
9T21B1064G02 18.8 38.0 43.0 23.8
9T21B1040G02 18.8 38.0 43.0 23.8
Connection Diagram C C D D D D C C
Page 10-61
1The load kVA is the maximum load at voltages shown when transformers are connected as autotransformers according to the diagram referenced.
Table 5
230 Volts, 3-Wire Output, 60 Hertz, Three-Phase 2
Available Line Voltage
181Y/105 192Y/111 203Y/117 208Y/120 277Y/160
Quantity Required Product
Per Bank Number Load kVA1
3 9T51B0102 0.830 1.7
3 9T51B0122 0.620 1.3
3 9T51B0202 0.480
3 9T51B0103 1.2 2.5
3 9T51B0123 0.930 1.9
3 9T51B0203 0.720
3 9T51B0104 1.7 3.4
3 9T51B0124 1.2 2.5
3 9T51B0204 0.960
3 9T51B0105 2.5 5.0
3 9T51B0125 1.9 3.7
3 9T51B0205 1.44
3 9T51B0107 4.2 8.3
3 9T51B0127 3.1 6.2
3 9T51B0207 2.4
3 9T51B0108 8.3 16.6
3 9T51B0128 6.2 12.5
3 9T51B0208 4.8
3 9T51B0109 12.5 25.0
3 9T51B0129 9.3 18.7
3 9T51B0209 7.2
3 9T51B0110 16.6 33.2
3 9T51B0130 12.5 25.0
3 9T51B0210 9.6
3 9T51B0111 25.0 50.0
3 9T51B0131 18.7 37.0
3 9T51B0211 14.4
3 9T51B0112 33.0 66.0
3 9T51B0132 25.0 50.0
3 9T51B0212 19.2
3 9T51B0113 50.0 100.0
3 9T51B0133 37.5 75.0
3 9T51B0213 28.8
3 9T21B1037G02 83.0 167.0
3 9T21B1040G02 62.0 125.0
Connection Diagram F F G G F
Page 10-61
1The load kVA is the maximum load at voltages shown when transformers are connected as autotransformers according to the diagram referenced.
2See Caution page 10-59, footnote 1.
Table 6
240 Volts, 3-Wire Output, 60 Hertz, Three-Phase 2
Available Line Voltage
189Y/109 200Y/115 208Y/1203 218Y/126 288Y/166
212Y/122
Quantity Required Product
Per Bank Number Load kVA1
3 9T51B0102 0.870 1.7
3 9T51B0122 0.650 1.3
3 9T51B0202 0.500
3 9T51B0103 1.3 2.6
3 9T51B0123 0.970 2.0
3 9T51B0203 0.750
3 9T51B0104 1.7 3.5
3 9T51B0124 1.3 2.6
3 9T51B0204 1.0
3 9T51B0105 2.6 5.2
3 9T51B0125 2.0 3.9
3 9T51B0205 1.5
3 9T51B0107 4.3 8.7
3 9T51B0127 3.2 6.5
3 9T51B0207 2.5
3 9T51B0108 8.7 17.3
3 9T51B0128 6.5 13.0
3 9T51B0208 5.0
3 9T51B0109 13.0 26.0
3 9T51B0129 9.7 19.5
3 9T51B0209 7.5
3 9T51B0110 17.3 34.6
3 9T51B0130 13.0 26.0
3 9T51B0210 10.0
3 9T51B0111 26.0 52.0
3 9T51B0131 19.5 39.0
3 9T51B0211 15.0
3 9T51B0112 35.0 70.0
3 9T51B0132 26.0 52.0
3 9T51B0212 20.0
3 9T51B0113 52.0 104.0
3 9T51B0133 39.0 78.0
3 9T51B0213 30.0
3 9T21B1037G02 87.0 173.0
3 9T21B1040G02 65.0 130.0
Connection Diagram F F G G F
Page 10-61
1The load kVA is the maximum load at voltages shown when transformers are connected as autotransformers according to the diagram referenced.
2See Caution page 10-59, footnote 1.
3When 208Y/120 Volts is the available line voltage, the 212Y/122 column may be used to obtain 236 Volts which should be satisfactory for most applications.
Table 7
460 Volts, 3-Wire Output, 60 Hertz, Three-Phase 1
Available Line Voltage 3- or 4-Wire
385 406 418 432 438
Quantity Required Product
Per Bank Number Load kVA2
3 9T51B0102 1.66 3.32
3 9T51B0122 1.25 2.49
3 9T51B0202 0.830
3 9T51B0103 2.48 4.96
3 9T51B0123 1.87 3.73
3 9T51B0203 1.2
3 9T51B0104 3.31 6.62
3 9T51B0124 2.49 4.97
3 9T51B0204 1.7
3 9T51B0105 4.97 9.94
3 9T51B0125 3.73 3.9
3 9T51B0205 2.5
3 9T51B0107 8.28 16.6
3 9T51B0127 6.22 6.5
3 9T51B0207 4.2
3 9T51B0108 16.6 33.2
3 9T51B0128 12.5 13.0
3 9T51B0208 8.3
3 9T51B0109 24.8 59.6
3 9T51B0129 18.7 19.5
3 9T51B0209 12.5
3 9T51B0110 33.1 66.2
3 9T51B0130 24.9 26.0
3 9T51B0210 16.6
3 9T51B0111 49.7 99.4
3 9T51B0131 37.3 39.0
3 9T51B0211 24.9
3 9T51B0112 66.3 133.0
3 9T51B0132 49.7 52.0
3 9T51B0212 33.2
3 9T51B0113 99.3 198.6
3 9T51B0133 74.6 78.0
3 9T51B0213 49.8
3 9T21B1037G02 166.0 322.0
3 9T21B1040G02 125.0 130.0
Connection Diagram F H H I I
Page 10-61
1Caution: If input is 3-wire Delta or 4-wire midtapped Delta, the neutral established from the bank of buck-boost transformers must be insulated and isolated
from the input power neutral and/or ground.
2The load kVA is the maximum load at voltages shown when transformers are connected as autotransformers according to the diagram referenced.
Table 8
480 Volts, 3-Wire Output, 60 Hertz, Three-Phase1
Available Line Voltage 3- or 4-Wire
400 424 436 450
Quantity Required Product
Per Bank Number Load kVA2
9T51B0102 1.74
3 9T51B0122 1.3 2.6
3 9T51B0202 0.866
3 9T51B0103 2.6
3 9T51B0123 1.95 3.9
3 9T51B0203 1.3
3 9T51B0104 3.5
3 9T51B0124 2.6 5.2
3 9T51B0204 1.7
3 9T51B0105 5.2
3 9T51B0125 3.9 7.8
3 9T51B0205 2.6
3 9T51B0107 8.7
3 9T51B0127 6.3 13.0
3 9T51B0207 4.3
3 9T51B0108 17.4
3 9T51B0128 13.0 26.0
3 9T51B0208 8.7
3 9T51B0109 26.0
3 9T51B0129 19.5 39.0
3 9T51B0209 13.0
3 9T51B0110 35.0
3 9T51B0130 26.0 52.0
3 9T51B0210 17.3
3 9T51B0111 52.2
3 9T51B0131 39.0 78.0
3 9T51B0211 26.0
3 9T51B0112 69.0
3 9T51B0132 52.0 104.0
3 9T51B0212 34.6
3 9T51B0113 104.0
3 9T51B0133 78.0 156.0
3 9T51B0213 51.9
3 9T21B1037G02 174.0
3 9T21B1040G02 130.0 260.0
Connection Diagram F H H I
Page 10-61
Table 9
208 Volts, 3-Wire, 60 Hertz, Three-Phase1
Available Line Voltage 3- or 4-Wire
218 222 229 236
Quantity Required Product
Per Bank Number Load kVA2
2 9T51B0102 1.6 0.800
2 9T51B0122 1.2 0.640
2 9T51B0103 2.3 1.2
2 9T51B0123 1.8 0.960
2 9T51B0104 3.2 1.6
2 9T51B0124 2.4 1.3
2 9T51B0105 4.7 2.5
2 9T51B0125 3.6 1.9
2 9T51B0107 7.8 4.1
2 9T51B0127 6.0 3.2
2 9T51B0108 16 8.0
2 9T51B0128 12.0 6.4
2 9T51B0109 23.6 12.4
2 9T51B0129 18.0 9.6
2 9T51B0110 31.5 16.5
2 9T51B0130 24.0 12.7
2 9T51B0111 47.5 24.8
2 9T51B0131 36.0 19.1
2 9T51B0112 63.0 33.0
2 9T51B0132 48.0 25.6
2 9T51B0113 94 49.6
2 9T51B0133 72.0 38.3
Connection Diagram J J Z Z
Page 10-61
1Caution: If input is 3-wire Delta or 4-wire midtapped Delta, the neutral established from the bank of buck-boost transformers must be insulated and isolated
from the input power neutral and/or ground.
2The load kVA is the maximum load at voltages shown when transformers are connected as autotransformers according to the diagram referenced.
Connection Diagrams
Fuse Guide
Midget Class CC Rejection Fuse
Transformer Continuous Power Rating (VA)
Primary 50 75 100 150 200 250 300 375 500
Voltage Fuse Rating (Amperes)
100 1.50 2.00 3.00 4.00 3.00 4.00 5.00 6.00 8.00
110 1.25 2.00 2.50 4.00 5.00 3.00 4.00 5.00 7.00
120 1.25 1.60 2.50 3.00 5.00 3.00 4.00 5.00 6.00
200 0.75 1.00 1.50 2.00 3.00 3.00 4.00 5.00 4.00
208 0.60 1.00 1.25 2.00 2.50 3.00 4.00 5.00 4.00
220 0.60 1.00 1.25 2.00 2.50 3.00 4.00 5.00 3.00
230 0.60 0.80 1.25 1.60 2.50 3.00 3.00 4.00 3.00
240 0.60 0.80 1.25 1.60 2.50 3.00 3.00 4.00 3.00
277 0.50 0.80 1.00 1.60 2.00 2.50 3.00 4.00 5.00
380 0.30 0.50 0.75 1.00 1.50 1.60 2.00 2.50 3.00
400 0.30 0.50 0.75 1.00 1.50 1.60 2.00 2.50 3.00
416 0.30 0.50 0.60 1.00 1.25 1.60 2.00 2.50 3.00
440 0.30 0.50 0.60 1.00 1.25 1.60 2.00 2.50 3.00
460 0.30 0.40 0.60 0.80 1.25 1.60 1.60 2.00 3.00
480 0.30 0.40 0.60 0.80 1.25 1.50 1.60 2.00 3.00
550 0.25 0.40 0.50 0.80 1.00 1.25 1.60 2.00 2.50
575 0.25 0.30 0.50 0.75 1.00 1.25 1.50 1.60 2.50
600 0.25 0.30 0.50 0.75 1.00 1.25 1.50 1.60 2.50
Diagram 1 Diagram 5
Diagram 2 Diagram 6
Diagram 3 Diagram 7
Diagram 4 Diagram 8
Style AA Style AB
(Terminal Blocks) Top (Leads Out)
Top
E
E
G G
(MTG Slot) F (MTG Slot)
F
B A B A
C C
S
T
50/60 Hz
Input Output Approx. Net Frame Product
Voltage Voltage kVA Weight (Lbs) Size Number
230/400 Volts 12/24 Volts 0.025 3 6100 9T58E0020
230/400 Volts 12/24 Volts 0.05 4 6150 9T58E0021
230/400 Volts 12/24 Volts 0.075 4 8100 9T58E0023
230/400 Volts 12/24 Volts 0.1 5 8150 9T58E0024
230/400 Volts 12/24 Volts 0.15 7 8200 9T58E0025
230/400 Volts 12/24 Volts 0.2 12 10225 9T58E0026
230/400 Volts 12/24 Volts 0.25 12 10225 9T58E0027
230/400 Volts 12/24 Volts 0.3 12 10225 9T58E0028
230/400 Volts 12/24 Volts 0.375 16 12225 9T58E0029
230/400 Volts 24/48 Volts 0.05 4 6150 9T58E0061
230/400 Volts 24/48 Volts 0.075 4 8100 9T58E0063
230/400 Volts 24/48 Volts 0.1 5 8150 9T58E0064
230/400 Volts 24/48 Volts 0.15 7 8200 9T58E0065
230/400 Volts 24/48 Volts 0.2 12 10225 9T58E0066
230/400 Volts 24/48 Volts 0.5 19 12300 9T58E0071
230/400 Volts 24/48 Volts 0.75 28 14225 9T58E0073
220/380, 230/400, 240/415 Volts 110/220, 115/230, 120/240 Volts 0.025 3 6100 9T58E0150
220/380, 230/400, 240/415 Volts 110/220, 115/230, 120/240 Volts 0.05 4 6150 9T58E0151
220/380, 230/400, 240/415 Volts 110/220, 115/230, 120/240 Volts 0.075 4 8100 9T58E0153
220/380, 230/400, 240/415 Volts 110/220, 115/230, 120/240 Volts 0.1 5 8150 9T58E0154
220/380, 230/400, 240/415 Volts 110/220, 115/230, 120/240 Volts 0.15 7 8200 9T58E0155
220/380, 230/400, 240/415 Volts 110/220, 115/230, 120/240 Volts 0.2 12 10225 9T58E0156
220/380, 230/400, 240/415 Volts 110/220, 115/230, 120/240 Volts 0.25 12 10225 9T58E0157
220/380, 230/400, 240/415 Volts 110/220, 115/230, 120/240 Volts 0.3 12 10225 9T58E0158
220/380, 230/400, 240/415 Volts 110/220, 115/230, 120/240 Volts 0.375 16 12225 9T58E0159
220/380, 230/400, 240/415 Volts 110/220, 115/230, 120/240 Volts 0.5 19 12300 9T58E0161
220/380, 230/400, 240/415 Volts 110/220, 115/230, 120/240 Volts 0.75 28 14225 9T58E0163
220/380, 230/400, 240/415 Volts 110/220, 115/230, 120/240 Volts 1 34 14300 9T58E0164
220/380, 230/400, 240/415 Volts 110/220, 115/230, 120/240 Volts 1.5 45 14475 9T58E0165
NOTES:
Panelboards Section 11
A-Series II Panelboards
Applications................................................................................................11-3
Types..............................................................................................................11-4
Terminal Lugs............................................................................................ 11-7
Pricing and Ordering.............................................................................. 11-8
Column Panels.......................................................................................... 11-9
Column Field Installed Kits/Replacement
Parts/Enclosures.................................................................................11-10
Lighting Control PanelRemote Operated
Circuit Breakers...................................................................................11-11
Pro-Stock Panelboards Unassembled.....................................11-13
Product Options..................................................................................... 11-19
Accessories.............................................................................................. 11-20
Power Panelboards.............................................................................. 11-21
Branch Circuit Monitoring.................................................................11-23
AMP1 Integrated Power and Energy............................................11-24
Spectra Series Panelboards................................................. 11-25
Fusible Switches Load and Interrupting Ratings................... 11-26
Merchandisable Kits and Sizing Information...........................11-28
Terminal Lugs..........................................................................................11-29
PCU Selection..........................................................................................11-30
Interior, Enclosure Options................................................................11-31
Integrated Submetering Panelboard...........................................11-33
Renewal Parts Modular Concept...................................................11-34
Renewal Parts Circuit Breaker Sizing...........................................11-35
Replacement Boxes and Fronts..................................................... 11-36
Renewal Parts Product Number Structure............................... 11-38
Renewal Parts Mounting Hardware......................................... 11-41
Renewal Parts Main Lug Modules;
Neutral and Ground Kits.................................................................11-46
Renewal Parts Accessories...........................................................11-47
Renewal Parts Interiors, Boxes and Fronts...........................11-48
Renewal Parts Type SCP Panelboards.................................... 11-49
Renewal Parts Type CCB and QMR Panelboards............... 11-50
Available Publications............................................................. 11-53
NEMA PB1.
Federal Specifications
Panelboards, W-P-115c.
Type 1Circuit breaker equipped
Class 1Panelboards
Class 2Load centers
Molded case circuit breakers, WC-375B/GEN.
Fusible switches, W-S-865c.
Application Features
The following classifications and limitations of panelboards have Symmetrical design, no required top or bottom mountings
been established by the Underwriters Laboratories and the Wide, easy-to-install galvanized enclosures with removable
National Electrical Code. Note an overcurrent protective device endwalls
is a circuit breaker pole or single fuse. Panelboards have no fire
Flush or surface mounting
wall ratings. All 50/60 Hz rated. There is no limitation as to the
number and rating of branch circuits, except as determined by Standard concealed mounting hardware and hinges
available enclosures. Interiors that allow straight-in wiring
Split neutral
Interrupting RatingsCircuit Breakers Field-installable, UL Listed, 200% neutral for non-linear loads
Panelboards have integrated short circuit ratings. When fully Branch-bus direct connection
rated, the rating is that of the lowest rated device in the panel-
Captive hardware on branch breakers
board. When series connected rated, the rating is that of the
main device in panel (or remote line side protected device) and Short circuit ratings allow up to 100KA @ 480Y/277Vac; 200KA
branch-tested/UL Listed combination. @ 240Vac
Main bus ratings of 125 to 800 amps copper, 125 to 600 amps
aluminum
Short-Circuit RatingsFusible Switch Units
Spectra RMS and vertically mounted main circuit breakers
The interrupting rating of the fuse must equal or exceed the
short-circuit rating of the switch. If it is lower, then the interrupt- available
ing rating of the switch is the same as the fuse. Switches have no Bus-connected TVSS for maximum surge protection
short-circuit rating if renewable fuses are used. Optional door-in-door or front-hinged-to-box door
Enclosures available in NEMA Type 1, Type 3R/12, Type 4/4X
Seismic Ratings
All A-Series II Lighting Panels and Spectra Power Panels have
been tested and certified to meet the International Building Code
(IBC) Zone 3 and Zone 4 as well as the California Building Code
(CBC) Zone 4.
Type AQ
Service Information:
1P, 3W-120/240 Vac
3P, 3W-240 Vac
3P, 4W-240/120 Vac, 208/120 Vac
Fully Rated: 65kAIC at 240V
Series Rated: 200kAIC at 240V
Mains
Breakers:
100A-THQB, THHQB, TEY, SE, FE
225A-TQD, THQD, SF, FE
400A-TJD, SG, FG
600A-SG
800A-SK
Main Lug:
125-800A
Branch Breakers (Bolt-on):
Amperage-15-100A
Poles-1, 2, 3
Types-THQB, THHQB, TXQB
Enclosures
Length-25.5, 31.5, 37.5, 43.5, 49.5, 55.5, 64.5, 76.5, 82.5, 88.5
Width-20
Depth-5.81
Type AD
Service Information:
3P, 3W-480 Vac, 600 Vac
3P, 4W-208/120 Vac, 480/277 Vac, 600/347 Vac
Fully Rated: 35kAIC at 600Y/347V, 100kAIC at 480V
Series Rated: 35kAIC at 600Y/347V
Mains
Breakers:
150A-THED, SE
225A-TFJ, SF
400A-TJJ, SG
600A-SG
800A-SK
Main Lug:
150-800A
Branch Breakers (Bolt-on):
Amperage-15-100A (1P, 2P)
15-150A (3P)
220A Max. double branch
Types-TED, SE, FB
Enclosures
Length-31.5, 37.5, 43.5, 49.5, 55.5, 64.5, 76.5, 82.5, 88.5
Width-20
Depth-5.81
Panelboard Types
Max. Main Lug 800A 800A 800A 800A 400A 225A 225A 225A 1200A
Amperes
Max. Main Breaker 800A 800A 800A 800A 400A 225A 225A 225A 1200A
or Switch Amperes
THQB, THHQB, TQD, THQD, TEY, TFJ, TJJ, TEYF, TEY, SE, TFJ, THQB, THHQB, TQD, TEY, TFJ, SF, SG, SK,
THED, TFJ, TJJ
Main Devices TEY, TJD, TFJ TEYD, TEYH, TEYL SF, TJJ, THQD, TEY, TFJ, SE, SF ADS Switches,
SE, SF, SG, SK SG SE, SF FB, FC, FE, FG
Subfeeds
Max. Amps 225 225 225 225 225 150 150 150
(100% Rated)
Subfeed
TQD, THQD TQD, THQD TED, TFJ, SE, SF TED, TFJ, SE, SF TED, TFJ, SE, SF TQD, THQD TQD, THQD TED
Breaker Types
Information Required to Price and Order a Panelboard How to Price Factory Assembled Panelboards
Short-circuit Rating (10kA, 18kA, etc.) Main Price (or Interior Price for A-Series II) + Branch Circuits +
Service Entrance Label (Yes) or (No) Options = Total List of Panelboard. The sum of these list prices is
the total list for the complete panelboard including box and front.
Mark(s) (LPA, MDP, RPC, etc.)
Please refer to Speedi for quoting, pricing and ordering GE panels
Service (3-ph, 4-w 208Y/120; 3-ph, 3-w 480 volts, etc.)
Entrance of Incoming Line (Top) or (Bottom).
How to Lay Out Factory Assembled Panelboards
(Bottom Supplied as Standard)
Multi-section panels must have a main circuit breaker or main
Trim (Surface) or (Flush)
lugs in each section. Double (dual) main lugs or thru-feed lugs
Incoming Wire Size (500kcmil, 250kcmil, etc.) must be added as required in all but the last section.
Incoming Number of Wires per phase (1, 2, 3, etc.) Please refer to Speedi for quoting, pricing and ordering GE panels
Wire Material (Copper or Aluminum)
Main Type (Main Lugs Only, Circuit Breaker, Fusible Switch, etc.) How to select a Pro-Stock, unassembled panelboard
Amperage of Main Bus Total the following components:
Interior
Frame of Main Circuit Breaker (SG, SK, TJK, etc.) (if applicable)
Box (add ground bars as required)
Options to Mains (Shunt Trip, Lighting Contactor, etc.)
Front
Equipment Ground (Optional)
Main breaker or lug kit
Branches
Amp Rating (20, 30, 50, etc.) Subfeed breaker or feed thru lug kit (if required)
Poles (1, 2, or 3) Branch Breakers (from Section 3)
Frame (THQB, TED, etc.) Accessories (200% neutral, service entrance etc.)
Quantity (1, 10, 15, etc.)
Please consult your local distributor for net pricing and current
Options: stock levels.
Interior (Copper bus, 200% rated neutral, etc.)
Box (Painted, Increased Gutter, etc.) For additional details on selecting Pro-Stock panelboards, please
Front (Door in Door, etc.) refer to publication DEP-104.
Ground Fault Protection (Yes) or (No)
Type of Panel (AQ, AE, Spectra Bolt-on, etc.)
Type AQC
Service Information:
1P, 3W-240/120 Vac
3P, 3W-240 Vac
3P, 4W-240 Vac
Mains
Breakers:
100A-THQB, THHQB, TEY, SE
225A-TQD, THQD, SF
Main Lug:
125-225A
Branch Breakers (Bolt-on):
Amperage-15-100A (1P, 2P, 3P)
Types-THQB, THHQB, TXQB
Enclosures
Length-37.5, 43.5, 49.5, 55.5, 64.5, 76.5
Width-8.62
Depth-5.81
TEY TEYPLD1
TED, TEL TEFPLD1
TQD TQDPLD1
TFJ, TFL TFKPLD1
Filler Plate for Q Line
and TEY Breakers TQLFP1
Accessories
Product
Description Number
Programming Software ASROCBPRGM
PC-based start up software
Daylight Optimization Module ASRGLCDOK
Performs sunlight harvesting by measuring the
amount of light and provides a control signal to a
dimming mechanism to maintain a preset lighting level.
Remote Switch Expansion Module ASRGLCDSK
Provides additional 16 digital input
signals to the controller for each module
Control Wiring Insulation Tubing ASRGLCCWT
Requirement per UL67 and NEC725.55, that low
voltage class 2 and 3 control wiring be separated with
tubing having an insulation rating equal to branch load wiring.
Programming Software
Dimming Module
Aluminum Bus
Rating No. of Feed-thru Box/Front TGL2
Voltage (Amps) Circuits Product Number1 Height Ground Bars2,3
18 AQU1182RCXAXT1 37.5" 2
240 Vac,
100-225 30 AQU1302RCXAXT1 43.5" 3
1 Phase
42 AQU1422RCXAXT1 49.5" 4
18 AQU3182RCXAXT1 37.5" 2
208/120 Vac,
100-225 30 AQU3302RCXAXT1 43.5" 3
3 Phase
42 AQU3422RCXAXT1 49.5" 4
18 AEU3182RCXAXT1 37.5" 2
480/277 Vac,
100-225 30 AEU3302RCXAXT1 43.5" 3
3 Phase
42 AEU3422RCXAXT1 49.5" 4
2 Select Box
Select a box of the correct height (see Step 1). Boxes come with blank endwalls.
If endwalls with knockouts are required, also order knockout endwall kit AKEW2.
NEMA 3R/12
3 Select Front
Select a front of the correct height (see Step 1).
Standard (20" wide) Door Within Door (20" wide) Front Hinged To Box (20" wide) Standard (30" Wide)
Front Height Flush1 Surface1 Flush1 Surface1 Flush1 Surface1 Flush1 Surface1
31.5" AF31F AF31S AF31FP AF31SP AF31FD AF31SD AF31FW AF31SW
37.5" AF37F AF37S AF37FP AF37SP AF37FD AF37SD AF37FW AF37SW
43.5" AF43F AF43S AF43FP AF43SP AF43FD AF43SD AF43FW AF43SW
49.5" AF49F AF49S AF49FP AF49SP AF49FD AF49SD AF49FW AF49SW
64.5" AF64F AF64S AF64FP AF64SP AF64FD AF64SD AF64FW AF64SW
76.5" AF76F AF76S AF76FP AF76SP AF76FD AF76SD AF76FW AF76SW
1For CSA label, add "A" suffix to product number.
Note: 400A and 600A breaker kits cannot be used for sub-feed applications in Pro-Stock panelboards.
MB513 Breaker Kit MB516 6-Pole Breaker Kit MB233WB WB Breaker Kit
Skip Step 5 if you selected a main breaker kit ending in WB All TQD and Spectra main breakers require line-side lugs.
no breaker is required. For TEY and THQB main breakers, see branch breakers tables in
To correlate breaker types with the kAIC rating in specific panel- Step 7.
boards, see the table for Step 4. For more rating details, see
A-Series II Lighting Panels Rating Series Labels (DEH-40007).
Digital, Solid State Spectra RMS Breakers (3-pole) For use with appropriate main breaker kit (see Step 4).
Breaker Rating Plug1 Terminal Lugs for Front Connection2
Current Amp Wire Range
Poles Sensor Product Number Rating Product Number Product Number (Cu/Al)
SEDA36AT0100
SEHA36AT0100
100 100 SRPE100A100
SELA36AT0100
SEPA36AT0100 TCAL18 #12-3/0
SEDA36AT0150 110 SRPE150A110
150 SELA36AT0150 125 SRPE150A125
SEPA36AT0150 150 SRPE150A150
3 70 SRPF250A70
90 SRPF250A90
100 SRPF250A100
SFHA36AT0250 110 SRPF250A110
250 SFLA36AT0250 125 SRPF250A125 TCAL29 #8-350 MCM
SFPA36AT0250 150 SRPF250A150
175 SRPF250A175
200 SRPF250A200
225 SRPF250A225
125 SRPG400A125
SGHA36AT0400
150 SRPG400A150
3 400 SGLA36AT0400
175 SRPG400A175 TCLK365
SGPA36AT0400
200 SRPG400A200
225 SRPG400A225 Al: (2) 2/0-500
SGHA26AT0400 250 SRPG400A250 MCM or (1)
2 400 SGLA26AT0400 300 SRPG400A300 TCLK265 #6-600 MCM
SGPA26AT0400 350 SRPG400A350 Cu: (2) 2/0-400
400 SRPG400A400 MCM or (1)
250 SRPG600A250 #8-600 MCM
SGLA36AT0600
3 600 300 SRPG600A300 TCLK365
SGPA36AT0600
350 SRPG600A350
400 SRPG600A400
2 600 SGLA26AT0600 500 SRPG600A500 TCLK265
SGPA26AT0600 600 SRPG600A600
1Any rating plug within a given current sensor group may be paired with any breaker in that group.
2Except for WB kits, lugs must be ordered separately for Spectra breakers. All Spectra breakers also require an appropriate rating plug.
Main or subfeed breakers for use with AQ panels (208/120 Vac 3-phase or 240 Vac single phase). See Step 4.
2-pole 3-pole
10kAIC 22kAIC 10kAIC 22kAIC
Amp Product3 Product Product3 Product
Rating Number Number Number Number
100 TQD22100X2 THQD22100X2 TQD32100X2 THQD32100X2
125 TQD22125X2 THQD22125X2 TQD32125X2 THQD32125X2
150 TQD22150X2 THQD22150X2 TQD32150X2 THQD32150X2
175 TQD22175X2 THQD22175X2 TQD32175X2 THQD32175X2
200 TQD22200X2 THQD22200X2 TQD32200X2 THQD32200X2
225 TQD22225X2 THQD22225X2 TQD32225X2 THQD32225X2
250 TJD422250L2 TJD432250L3
300 TJD422300L2 TJD432300L3
350 TJD422350L2 TJD432350L3
400 TJD422400L2 TJD432400L3
Main or subfeed breakers for use with AE panels (480/277 Vac 3-phase). See Step 4.
3-pole
18kAIC 22kAIC 30kAIC
Amp Rating Product Number Product Number Product Number
100 TED134110WL THED134110WL MB233WB
125 TED134125WL THED134125WL MB233WB
150 TED134150WL THED134150WL MB233WB
175 MB233WB
200 MB233WB
225 MB233WB
250 TJJ436250L3
300 TJJ436300L3
350 TJJ436350L3
400 TJJ436400L3
3Any load-side lugs on TQD breakers must be removed before assembly. TQD breakers with X2 product number suffix feature line-side lugs only.
Accessories
Service Entrance3 ProCare Kit4
Amp Rating Product Number Description Product Number
225A BNDKT ProCare Kit for Pro-Stock PROCARE
400A BNDKT6 panelboard installation
and maintenance
600A BNDKT6
4ProCare Kit includes: (5) filler plate hardware kits, (9) bus stud nuts, (5) MLA1 filler
3Service entrance kit includes a bonding strap with hardware and a service
entrance label. plates, (2) 225A phase barriers, (2) feed-thru barriers, (1) 400/600A phase barrier,
(50) directory cards/rating books, (50) circuit number strips (1-48), (50) circuit
number strips (43-84), (5) standard locks and keys, (50) deadfront screws, (10)
AQ/AE front hardware kits, (10) AD front hardware kits, (50) service disconnect
labels, (50) main labels.
7 Typical Bolt-On Branch Breakers
These tables show typical branch breakers, but do not include all branch breakers that can be used with Pro-Stock panelboards.
Branch circuit breakers for use with AQ panels (208/120 Vac 3-phase or 240 Vac single phase)
10kAIC 22kAIC
1-pole 2-pole 3-pole 1-pole 2-pole 3-pole
Amp Product Product Product Product Product Product
Rating Number Number Number Number Number Number
15 THQB1115 THQB2115 THQB32015 THHQB1115 THHQB2115 THHQB32015
20 THQB1120 THQB2120 THQB32020 THHQB1120 THHQB2120 THHQB32020
25 THQB1125 THQB2125 THQB32025 THHQB1125 THHQB2125 THHQB32025
30 THQB1130 THQB2130 THQB32030 THHQB1130 THHQB2130 THHQB32030
35 THQB1135 THQB2135 THQB32035 THHQB1135 THHQB2135 THHQB32035
40 THQB1140 THQB2140 THQB32040 THHQB1140 THHQB2140 THHQB32040
45 THQB1145 THQB2145 THQB32045 THHQB1145 THHQB2145 THHQB32045
50 THQB1150 THQB2150 THQB32050 THHQB1150 THHQB2150 THHQB32050
60 THQB1160 THQB2160 THQB32060 THHQB1160 THHQB2160 THHQB32060
70 THQB1170 THQB2170 THQB32070 THHQB1170 THHQB2170 THHQB32070
80 THQB2180 THQB32080 THHQB2180 THHQB32080
90 THQB2190 THQB32090 THHQB2190 THHQB32090
100 THQB21100 THQB32100 THHQB21100 THHQB32100
Branch circuit breakers for use with AE panels (480/277 Vac 3-phase)
14kAIC
1-pole 2-pole 3-pole
Product Product Product
Amp Rating Number Number Number
15 TEY115 TEY215 TEY315
20 TEY120 TEY220 TEY320
30 TEY130 TEY230 TEY330
40 TEY140 TEY240 TEY340
50 TEY150 TEY250 TEY350
60 TEY160 TEY260 TEY360
70 TEY170 TEY270 TEY370
80 TEY180 TEY280 TEY380
90 TEY190 TEY290 TEY390
100 TEY1100 TEY2100 TEY3100
Interior Type
AQU 240 Vac Bus
AEU 480Y/277 Vac No. of Circuits B4 Copper
18 18 Circuits Blank Aluminum
30 30 Circuits
42 42 Circuits
Max. Amp
Phase T1 Feed-thru
Rating
1 1 Phase Blank Non Feed-thru* (requires copper bus [B4])
2 225A
3 3 Phase * For retrofit applications
4 400A
6 600A
Enclosure Options
AEBGC
Optional Equipment Grounds
Product Number
AEIG
TQLFP1
Product Number
TEDFP1
ASPGIBC
Endwall Kits
Field installed. For standard 20"w x 5.81"d boxes.
Product Number Description Qty.
ABEW2 Blank 1
AKEW2 Knockout 1
Panelboards Parts
Product List Price,
Description Number GO-101
Directory Card 139C5612P3 $2.00 Replacement Lock with Replacement Lock with
Replacement Lock with Std. Key 569B737P1 $22.00 Standard Key Black GE75 Key Red with no
Replacement Lock with GE75 Key 569B737P2 $22.00 with GE Monogram GE Monogram
Additional Keys for Above Lock 569B737P5 $2.00
Circuit Numbering Strips- Box Extensions
1-48 569B806G1 $4.00
Bolts to A-Series II box with or without box endwall in place.
49-84 569B806G2 $4.00
Extensions can be combined to obtain lengths greater than 18
85-126 569B806G3 $4.00
and 24 inches.
Adhesive Backed Lamicoid Nameplate 3/4 in. x 3 in. 315A7190P1 $27.00
Metal Directory Card Holder 139C5491G1 $50.00 Box Width Box Extension Box Extension
and Depth Box Mounting Length (Inches) Product Number
Directory Card Holder 139C5491P4 $10.00
9 ABX2509F
Delta Hi-leg Conversion Kit, to Add B-Phase
Flush 18 ABX2518F
Plug on AL Panels APHBL $60.00
24 ABX2524F
Bolt on AE/AQ Panels APHBQ $60.00
9 ABX2509S
NEMA 3R/12 Tamper Proof Tork Screw Kit NEMATRX $30.00
18 ABX2518S
2P to 3P TQD Conv. Kit ASP2PTQD3P $100.00
24 ABX2524S
2P to 3P SF Conv. Kit for horizontal subfeed ASP2PTFJ3P $100.00
1
20 x 5.81 31 ABX2531S
AD 25 to 65 kAIC Barrier kit ASP25AD65KA $100.00
37 ABX2537S
Service Entrance Kit ASPSERENT $50.00 Surface
43 ABX2543S
2 wire Relay Kit ASP2WRelay $286.00
49 ABX2549S
Yale Lock Kit ASPYALE47 $120.00
55 ABX2555S
Corbin Lock Kit ASPCORBNTEU1 $120.00
64 ABX2564S
2-3 pole TQD Mechanical Interlock TQDFM1 $120.00
76 ABX2576S
AQ/AL/AE Rail Bracket ASPAQLEBKT $20.00
18 ABX3518F
Front Flush Adjust Kit ASPFLUSHADJ $20.00 Flush
24 ABX3524F
AE Front Mounting Kit 139C5720G3 $30.00 30 x 5.81
18 ABX3518S
AQ/AL Front Mounting Kit 139C5720G6 $30.00 Surface
24 ABX3524S
AD Front Mounting Kit 139C5720G9 $30.00
18 ABX3718F
Front Hinge to Box Mounting Kit 139C5700G6 $20.00 Flush
24 ABX3724F
Front Extension Mounting Kit 139C5700G11 $20.00 30 x 7.81
18 ABX3718S
1 Surface
Included in factory assembled panelsAD panels with Spectra 24 ABX3724S
branch breakers.
Type AEP
Service Information:
1P, 3W-240/120 Vac
3P, 3W-240 Vac
3P, 4W-208/120 Vac, 480/277 Vac
Fully Rated- 18kAIC at 480/277 Vac, 65kAIC at 240Vac
Series Rated- 100kAIC at 480 Vac, 200kAIC at 240 Vac
Mains
Breakers:
125-800A: SG, SK
Main Lug:
600-800A
Branch Breakers (Bolt-on):
15A-100A (1P, 2P, 3P): TEY, TEYF
Double Branch- TED, SE
Center-Mounted-SF, SG
Enclosures
Length-25.5, 31.5, 37.5, 43.5, 49.5, 55.5, 64.5, 76.5, 82.5, 88.5
Width-30
Depth-8
Features
Solutions up to 800A
IEC Class 1 revenue grade metering accuracy
Offers Solid Core or Split Core BCM selection process
Monitor up to 50 panelboards on one RS-485 drop
Reports volts, amps, power, and energy for each circuit
Solid Core monitors 42 circuits (and optional mains)
Split Core monitors up to 66 circuits (and optional mains)
4 configurable alarm thresholds improve load management
Ability to set the orientation and numbering of the circuits
1/4 to 1251 Amp monitoring the widest range available
1-, 2-, 3-pole breaker support
5-year warranty
Modbus RTU via RS485 communications
1Must use Split Core BCM for 110A and 125A monitoring.
References
DEA-539 for additional information
Speedi for configuration/quotation purposes
Panelboards Section 11
A-Series II Panelboard
AMP1 Integrated Power and Energy
Features
Solutions up to 800A
Revenue Grade, ANSI 12.20 0.2% accuracy
Monitors voltage, amperage, power, and energy
Backlit LCD Display
Data logging option to ensure data is still preserved locally
Communicates via Modbus RTU or BACnet Versatile and
widely used protocols.
User-enabled password protection
UL-67 approved
5-Year warranty
Earn points towards LEED Certification
Meter
Type Product Number
Pulse AMP1B1
Modbus AMP1C2
Modbus & data logger AMP1C3
Bacnet & data logger AMP1H5
Panelboard
TYPE AQ TYPE AE TYPE AS
Max Voltage 240V 480Y/277V, 125/250 Vdc 480Y/277V, 125/250 Vdc
Max Amperage 800A 800A 800A
Fully Rated 65kAIC at 240V 18kAIC at 480Y/277V, 65kAIC at 240V 65kAIC at 480Y/277V, 100kAIC at 240V
Series Rated 200kAIC at 240V 100kAIC at 480V 100kAIC at 480V
Main Lug 600 Amp Max 600 Amp Max 600 Amp Max
Main Breakers QB, SE, SF, SG, SK TEY, TEYF, SE, SF, SG, SK TEYD/H/L, SE, SF, SG, SK
Branch Breakers 15A-100A, 1P, 2P, 3P QB 15A-100A, 1P, 2P, 3P TEY or TEYF 15A-100A, 1P, 2P, 3P TEYD/H/L
Optional Accessories
To add an AMP1 meter to an existing/non-metering panel, enclosure, CTs and fuse kit can be ordered separately.
Current Transformer1 Enclosure2 Fuse Kit3
Amp Rating Product Number AMP1N4 AMP1FUSE
100 AMP1V100A
200 AMP1V200A
300 AMP1V300A
400 AMP1V400A
600 AMP1V600A
800 AMP1V800A
1000 AMP1V1000A
1200 AMP1V1200A
2000 AMP1V2000A
1Qty 3 per meter required for three pole breaker applications; qty 2 per meter
required for two pole breaker applications.
2Qty 1 per meter required.
3Qty 1 per meter required.
Features
Main bus, 250-1200 amp, copper or aluminum
Wide, easy-to-install galvanized enclosures with removable
endwalls
5 box widths simplify installation and design
Bolt On
Enclosures available in NEMA Type 1, Type 3R/12, Type 4/4X
Service Information:
Integrated TVSS for maximum surge protection 1P, 3W-600/347 Vac
Optional door-in-door or front-hinged-to-box construction 3P, 4W-600/347 Vac
Reduced density copper or aluminum bus Fully Rated- 200KAIC at 480/277 Vac
200% rated neutrals available Series Rated- 200KAIC at 480/277 Vac
Mains
Vertically mounted main circuit breakers available Breakers:
Branch-bus direct connection 250A-1200A: SF, SG, SK, FG
Captive hardware on branch breakers Branch Breakers (Bolt-on):
Front accessible main lug assembly Double Branch-SE, SF, SG, FG, FB, TEY, TEB, TQD Breakers
Center-mounted-SK Breakers
Process control unit in plug-in style
Spectra MVT breaker option for main/branch breakers Plug In
100% rated breakers available Service Information:
Individual breaker cover plates 1P, 3W-600/347 Vac
3P, 4W-600/347 Vac
Fully Rated-200KAIC at 480/277 Vac
Series Rated-200KAIC at 480/277 Vac
Mains
Breakers:
250A-1200A: SF, SG, SK, FG
Branch Breakers/Switches (Plug In):
Double Branch-SE, SF, SG, FG, FB, TEY, TEB, TQD Breakers
Center-mounted- SK Breakers
30A-1200A Fused Switches (R, J, H, K, T Fuses)
Short Circuit RatingsFusible Switch Units (Plug-In Only) Maximum Horsepower Ratings1 ADS Fusible Switch
Maximum Volts, ac Volts, dc
Available Short-Circuit Rating
UL Amp Rating in Sym. Max. 2-Pole 3-Pole 2-Pole 2-Pole
in
Class Rating rms Amps Voltage Application Amps1 120 240 480 600 240 480 600 125 250
H 30-600 10,000 250/600 One-time general purpose With Standard Fuses
Fast-acting rejection sizing 30 1/2 1 1/2 3 3 3 5 7 1/2 2 5
J 30-600 200,000 600 mains & feeders, current limiting
60 1 1/2 3 5 10 7 1/2 15 15 5 10
50,000
100 7 1/2 10 15 15 25 30 20
K 30-600 100,000 250/600 Dual element no rejection means,
motor starting current limiting 200 15 25 30 25 50 60 40
200,000 50
400 50 100 125
Rejection means available in two forms 600 75 150 200 50
L 800-1200 200,000 600 Fast-acting mains & feeders With "Time-delay" Fuses
Time-delay motor starting 30 2 3 7 1/2 10 7 1/2 15 20 3
current limiting
60 3 10 20 25 15 30 50
100,000 Dual element rejection means, 100 15 30 40 30 60 75
R 30-600 250/600
200,000 motor starting current limiting
200 15 50 50 60 125 150
Fast-acting small physical size 400 125 250 350
T 100-600 200,000 250/600 mains & feeders, current limiting
600 200 400 500
1
Ratings are based on latest revision of the National Electrical Code
Article 430. Horsepower ratings for switches with Standard Class H
Panelboard Terminal Lugs - Main Lugs2 fuses are based on one-time fuses having minimum time-delay. When
time-delay fuses are used, the horsepower ratings are maximum for
and Neutral Incoming Lugs the switches.
Lighting Panels (A-Series II)
Panelboard Terminal Lugs (Cu-Al)
Spectra Optional Main Lug Terminations
Wire (Cu-Al) Max. # Lugs Per Phase
Max. Main Bus
Types Rating in Amps No. Per No. Per Lug Range 800A 800A
# Wires 1200A 1200A
125 1 1 #14-2/0
Per Lug 250-600A 21" 27"
225 1 1 #6-350kcmil
CU/AL Mechanical
AL 1 #4-600kcmil
AQ #6-350 kcmil 1 2 2 4
400 1 or
AE
2 1/0-250kcmil #2-500 kcmil 2 2 2 4
AD
600 1 2 2/0-500 mcm #2-600 kcmil 2 2 2 4
Breaker Side Gutter Space smallest, lowest amperage furthest from the main incoming. The
spaces, if any, will follow after the breakers. All main breakers are
EY, QB EY, QB A ENCLOSURE mounted horizontally and incoming lugs are, as a standard and if
SIDE WALL
not specified, always oriented to the left gutter regardless if top
T(H)E, SE, FC, FE T(H)E, SE, FC, FE B
or bottom feed. If 2 or more large branch breakers (SK, SG single
T(H)QD T(H)QD C mounted) are supplied with the board then the factory will start
T(H)J, SF T(H)J, SF D the first breaker with the lugs to the right and the second breaker
SG, FG SG, FG
with lugs to left and will continue staggering them until all have
E
been installed. If any further clarification is needed, please con-
FE J tact your local GE representative.
T(H)J, SF F Enclosure Width
Letter Reference 27 31 36 40 44
SG, FG G
A 7.88 9.88 12.38 14.38 16.38
Breakers are arranged, as a standard and if not specified, with H N/A N /A N/A 12.63 14.63
largest and highest amperage closest to main incoming and the J Breaker not available at time of printing
Spectra Series Main Lugs Top or Bottom Feed 240 Vac and 600 Vac, 200-1200 Amperes
Main Lug Kits (Factory Installed and/or Merchandise Panelboards)
Kit bolts directly to interior bus bars (either APN Plug-In Style or APNB Bolt-On Style).
Can be used for feed-through lug application by replacing standard cover plate with AFL feed-through cover plate kit (See
Accessories).
F suffix indicates all AFPML cover plates are included to fit applicable box widths. If cover plates are not necessary, remove the F suffix.
For 2 pole applications, replace the third digit or numeral 3 in the product number with the number 2.
Aluminum mechanical lugs can be converted to copper by replacing the first from last digit from an A to a C.
Spectra Series PCU Selection Guide Spectra PCU Control Power Transformer Kits
(Ref DET-104) Specify Overload Relay Amps One kit required per panel unless an external, 120VAC is brought
(Included w/PCU) into the panel.
Description: 15hp max, 22A, 600V max Continuous Primary
Configuration: 3PH, 3W, & ground; all units are 4X height, 120V kVA Voltage 2 Capacity Product Number
control. .200 600 Standard APCUCKA200
* Overload Range
B 0.16-0.26A
C 0.25-0.41A
D 0.40-0.65A
F 0.65-1.1A
G 1.0-1.5A
H 1.3-1.9A
J 1.8-2.7A
K 2.5-4.1A
L 4.0-6.3A
M 5.5-8.5A
N 8.0-12.0A
P 10.0-16.0A
S 14.5-18.0A
T 17.5-22.0A
X BLANK
2P 2P
TQD, THQD,
3P 3P TEB, TED
2P 2P THQB, THHQB,
TEY, THLC1,
THED, SE-Frame,
3P 3P FC (FE Future)
2P or 3P SG-Frame,
FG
THLC2, THLC4
2P or 3P
2P 2P SF-Frame, TFJ,
TFK, THFK
31" W
3P 3P
SF-Frame Double,
2P 2P FC (FE Future),
Branch Adjacent
to Switch
3P 3P
SF-Frame Single,
36" W Branch or Main
Adjacent to Switch
2P or 3P
THLC2, THLC4
3P 3P
3P 3P
SG-Frame
40" W FG
2P or 3P
TKM, THKM,
SKHA, SKLA
200% Neutral
Provides second neutral assembly of equal amperage rating.
Compression Lugs
Main Lugs, Neutral Lugs and Fusible Switches
The standard sizes and number of mechanical lugs are shown on
page 11-29.
Description Description
#12 1/0 500 kcmil
2/0-300 kcmil 600-750 kcmil
Example: APN 38 06 U B4
X Hgt of
Interior Ampere Rating Interior Type Modification Code
18 = 18X 02 = 200A U = Unassembled Blank = Standard
23 = 23X 04 = 400A (Aluminum Bus)
28 = 28X 06 = 600A B4 = Copper Bus
33 = 33X 08 = 800A (100A/sq in.)
38 = 38X 12 = 1200A
43 = 43X
48 = 48X
53 = 53X
Example: APNB 38 06 U B4
X Hgt of
Interior Ampere Rating Interior Type Modification Code
18 = 18X 02 = 200A U = Unassembled Blank = Standard
23 = 23X 04 = 400A (Aluminum Bus)
28 = 28X 06 = 600A B4 = Copper Bus
33 = 33X 08 = 800A (100A/sq in.)
38 = 38X 12 = 1200A
43 = 43X
48 = 48X
53 = 53X
Example: APB 36 89
Box Box
Width Height Modification Code
27 = 27" 65 = 65" Blank = Any box except APB2765
36 = 36" 75 = 75" A = For APB2765 with 18X interior
44 = 44" 89 = 89" B = For APB2765 with 23X interior
96 = 96" C = For APB2765 with 28X interior
Panelboard Front Type APF
Example: APF 89 38
Box X Hgt of
Height Interior Modification Code
65 = 65" 18 = 18X Blank = For Std Box (36" wide)
75 = 75" 23 = 23X S = For Slim Box (27" wide)
89 = 89" 28 = 28X W = For Wide Box (44" wide)
96 = 96" 33 = 33X E = Extra Line Gutter Space for
38 = 38X Dual Main Neutral
43 = 43X N = Nonvented Front
48 = 48X (for 250A only)
53 = 53X
Example: AMC 6 EB S FP
No. of Total CB Poles
on Module Breaker Frames Unit Type Accessory Code
6 = 6 poles QB = THQB, THHQB Blank = Std. FP = With Filler Plate Kit
(3-pole breakers, EY = TEY S = Special Type to allow (full width plates with
double branched) EB = TEB, TED, THED, SED, TFL, SE and SF to be cutouts for handles,
4 = 4 poles SEH, SEL, SEP mounted adjacent to etc.)
(2-pole breakers, FDB = FC a switch
double branched) FEB = FE Future
3 = 3 poles FJ = TFJ, TFK, THFK, TFL,
(3-pole breakers, SFH, SFL, SFP
single branched) JK = TJD, TJJ, TJK, THJK,
2 = 2 poles TJ4V, TJL4V
(2-pole breakers, LB = TLB4, THLC2, THLC4
single branched) GB or GM = SGD, SGH, SGL, SGP
FGB = FG
KM = TKM, THKM, TK4V, TKL4V,
SKH, SKL, SKP
FB = FB
Example: AMCB 6 EB B FP
Example: AEG 21 S
No. of
Circuits Modification Code
10 Blank = Std (bonded)
21 S = Insulated/Isolated
31
Product Features
Use to mount main or branch circuit breakers into panelboard. Breakers bolt on to the mounting modules.
FP suffix indicates that all AFP filler plates, with cutouts for handles, are included to fit all applicable box widths. On double branch modules,
filler plates to cover any unused breaker poles are also included.
Circuit breakers not included in module price.
Includes all necessary hardware.
Product Features
Module includes fusible switch and panelboard mounting connectors. Fuses not included.
Class R Fuse Clip Kit (for field installation) included with all switches that accept Class R Fuses.
FP suffix indicates that all AFP filler plates are included to fit applicable box widths.
Product Features
Module includes fusible switch and panelboard mounting connectors. Fuses not included.
Class R Fuse Clip Kit (for field installation) included with all switches that accept Class R Fuses.
FP suffix indicates that all AFP filler plates are included to fit applicable box widths.
Mounting Hardware With Filler Plate, Straps and Brackets Bolt-On Spectra
Mounting kit with filler plate includes hardware straps, brackets and filler plate.
Filler plate kit includes filler plate and associated hardware only.
Product
Mounting Arrangement Breaker Frame Number of Poles Box Width Range X Height Number
Dual Mounted TEB, TED 2-pole 27"-44" 2X AMCB4EBFP
Dual Mounted TEY 2-pole 27"-44" 3X AMCB4EYFP
Dual Mounted FBV, FBN, FBH, or FBL 2-pole 27"-44" 2X AMCB4FBFP
Dual Mounted FCS, FCV, FCN, FCH or FCL 2-pole 27", 31", 36", 40", 44" 3X AMCB4FDBFP
Dual Mounted FES, FEV, FEN, FEH or FEL 2-pole 27", 31", 36", 40", 44" 3X AMCB4FEBFP
Dual Mounted TQD, THQD 2-pole 27"-44" 2X AMCB4QDFP
Dual Mounted THED, SED, SEH, SEL, SEP 2-pole 27"-44" 3X AMCB4SEFP
Dual Mounted TEB, TED, THED, SED, SEH, SEL, SEP 3-pole 27"-44" 3X AMCB6EBFP
Dual Mounted TEY 3-pole 27"-44" 3X AMCB6EYFP
Dual Mounted FBV, FBN, FBH, or FBL 3-pole 27"-44" 3X AMCB6FBFP
Dual Mounted FCS, FCV, FCN, FCH or FCL 3-pole 27", 31", 36", 40", 44" 3X AMCB6FDBFP
Dual Mounted FES, FEV, FEN, FEH or FEL 3-pole 27", 31", 36", 40", 44" 3X AMCB6FEBFP
Dual Mounted TQD, THQD 3-pole 27"-44" 3X AMCB6QDFP
Dual Mounted SFH, SFL, SFP 2-pole 31"-44" 3X AMCB4FJFP
Dual Mounted SFH, SFL, SFP 3-pole 31"-44" 3X AMCB6FJFP
Dual Mounted TFJ, TFK, THFK 2-pole 36"-44" 2X AMCB4FJFPTF
Dual Mounted TFJ, TFK, THFK 3-pole 36"-44" 3X AMCB6FJFPTF
Dual Mounted FGV, FGN, FGH or FGP 2-pole 40", 44" 4X AMCB4FGBFP
Dual Mounted SGH, SGL, SGP 2-pole 40"-44" 4X AMCB4GBFP
Dual Mounted FGV, FGN, FGH or FGP 3-pole 40", 44" 4X AMCB6FGBFP
Dual Mounted SGH, SGL, SGP 3-pole 40"-44" 4X AMCB6GBFP
Single Mounted SFH, SFL, SFP 2-pole 27"-44" 3X AMCB2FJFP
Single Mounted TFJ, TFK, THFK 2-pole 27"-44" 3X AMCB2FJFPTF
Single Mounted FGV, FGN, FGH or FGP 2-pole 27", 31", 36", 40", 44" 4X AMCB2FGMFP
Single Mounted FES, FEV, FEN, FEH or FEL 2-pole 27", 31", 36", 40", 44" 3X AMCB2FEBFP
Single Mounted SGH, SGL, SGP 2-pole 27"-44" 4X AMCB2GMFP
Single Mounted SFH, SFL, SFP 3-pole 27"-44" 3X AMCB3FJFP
Single Mounted TFJ, TFK, THFK 3-pole 27"-44" 3X AMCB3FJFPTF
Single Mounted FGV, FGN, FGH or FGP 3-pole 27", 31", 36", 40", 44" 4X AMCB3FGMFP
Single Mounted FES, FEV, FEN, FEH or FEL 3-pole 27", 31", 36", 40", 44" 3X AMCB3FEBFP
Single Mounted SGH, SGL, SGP 3-pole 27"-44" 4X AMCB3GMFP
Single Mounted SKP 2-, 3-pole 44" 6X AMCB3KMFP
Single Mounted SKH, SKL, TKM, THKM 2-pole 40"-44" 6X AMCB2KMFP
Single Mounted SKH, SKL, TKM, THKM 3-pole 40"-44" 6X AMCB3KMFP
Filler Plates Plug-In or Bolt-On Spectra Mounting Hardware Single Breaker Plug-In Spectra
Use to cover unused spaces. Included when ordering AMC module. Only required when mount-
Includes filler plate support brackets and hardware. ing breaker on existing module.
Space Switchboard Product
Kit contains screws and washers to mount one circuit breaker on
X Height1 Box Width Range Section Widths Number AMC circuit breaker mounting module.
1X 27", 31" 35 APP1S Circuit Breaker Mounting Product
2X 27", 31" 35 APP2S Module Part Number Number
3X 27", 31" 35 APP3S
4X 27", 31" 35 APP4S AMC6EB AHKE1
5X 27", 31" 35 APP5S AMC4SE
6X 27", 31" 35 APP6S AMC4EB
1X 36", 40" 40 APP1 AMC6EBS
2X 36", 40" 40 APP2 AMC6EL AHKEL1
3X 36", 40" 40 APP3 AMC2FLS AHKF1
4X 36", 40" 40 APP4 AMC6FJ
5X 36", 40" 40 APP5 AMC4FJ
6X 36", 40" 40 APP6 AMC3FJ
1X 44" 45 APP1W AMC2FJ
2X 44" 45 APP2W AMC6FLS
3X 44" 45 APP3W AMC3FLS
4X 44" 45 APP4W AMC4FLS
5X 44" 45 APP5W AMC2GM AHKG1
6X 044" 45 APP6W AMC6GB
AMC4GB
1 X-height: 1X = 1 3/8"
AMC3GM
AMC2JK AHKJ1
AMC6JK
AMC4JK
Mounting Hardware Plug-In or Bolt-On Spectra ADS Switch AMC3JK
Replacement Load Base Kits AMC3LB AHKLB1
AMC6LB
Includes load base, clips and lugs. AMC4QD AHKQ1
Replacement AMC6QD
for Load Base Load Base Load Base - Load Base Product FCS, FCV, FCN, FCH or FCL AHKFD1
Part Number Ampere Rating No. of Poles Voltage Number FGV, FGN, FGH or FGP AHKFG1
ADS22030HD 331A1519G1
ADS32030HD 331A1519G2
ADS322060HD 331A1519G3 Mounting HardwareHardware only; no brackets
ADS32060HD 331A1519G4
ADS26030HD 331A1519G5 or straps Bolt-On Spectra
ADS36030HD 331A1519G6
Product
ADS26060HD 331A1519G7 Breaker Frame Number
ADS36060HD 331A1519G8
ADS36200JD 331A1519G12 SE AHKBE1
ADS26200JD 331A1519G16 SF AHKBF1
ADS36200JM 331A1519G20 SG AHKBG1
ADS26200JM 331A1519G22 THQD AHKBQ1
100A 2-pole 240V & 600V 331A1519G9 FCS, FCV, FCN, FCH or FCL AHKBFD1
100A 3-pole 240V & 600V 331A1519G10 FGV, FGN, FGH or FGP AHKBFG1
100A 3-pole 240V & 600V 331A1519G14 FB AHKBFB1
100A 2-pole 240V & 600V 331A1519G18
200A 3-pole 240V & 600V 331A1519G11
200A 2-pole 240V & 600V 331A1519G13
200A 2-pole 240V & 600V 331A1519G15
200A 2-pole 240V & 600V 331A1519G17
200A 3-pole 240V & 600V 331A1519G19
200A 2-pole 240V & 600V 331A1519G21
400A 2-pole 240V & 600V 331A1545G1
400A 3-pole 240V & 600V 331A1545G3
400A 2-pole 240V & 600V 331A1545G5
400A 3-pole 240V & 600V 331A1545G7
600A 2-pole 240V & 600V 331A1545G2
600A 3-pole 240V & 600V 331A1545G4
600A 2-pole 240V & 600V 331A1545G6
600A 3-pole 240V & 600V 331A1545G8
400-1200A 331A1543G1
4-pc Fronts
Panel Current Space X Box Box Product
Rating (amperes) Height Width/Depth Height (inches) Number
250 18 36" W x 11.5" D 64.63 APF6518N
250 28 36" W x 11.5" D 64.63 APF6528N
250 38 36" W x 11.5" D 89.25 APF8938N
250 53 36" W x 11.5" D 96.13 APF9653N
400 18 36" W x 11.5" D 64.63 APF6518
400, 800, 1200 28 36" W x 11.5" D 75.5 APF7528
400, 600, 800, 1200 38 36" W x 11.5" D 89.25 APF8938
600 23 36" W x 11.5" D 64.63 APF6523
400, 600, 800, 1200 48 36" W x 11.5" D 96.13 APF9648
800 23 36" W x 11.5" D 75.5 APF7523
800, 1200 43 36" W x 11.5" D 96.13 APF9643
400 18 44" W x 11.5" D 64.63 APF6518W
600 23 44" W x 11.5" D 64.63 APF6523W
800 23 44" W x 11.5" D 75.5 APF7523W
400, 1200 28 44" W x 11.5" D 75.5 APF7528W
400, 600, 800, 1200 38 44" W x 11.5" D 89.25 APF8938W
800, 1200 43 44" W x 11.5" D 96.13 APF9643W
400, 600 48 44" W x 11.5" D 96.13 APF9648W
Box dimensions are inside dimensions. Add 1/4-inch for outside dimensions.
Boxes furnished with no knockouts. Mounting HardwareFiller Plate and Filler Hardware
Maximum Breaker
Mounting Breaker Breaker Number Product
Arrangement Frame Amperage of Poles Number
Fronts
Dual Mounted SHE, SEL, 150A ACTFPKSE
Product
SED, SEP
Box Width/Depth X Height Box Height (inches) Number
Dual Mounted TEB, TED, THED 150A single-pole ACTFPKEB1P
31"W x 11.5"D 15 49.375 ACF3149S Dual Mounted TEB, TED, THED 150A two-pole ACTFPKEB2P
31"W x 11.5"D 18 53.5 ACF3153S Dual Mounted TEB, TED, THED 150A three-pole ACTFPKEB3P
31"W x 11.5"D 21 57.625 ACF3157S Dual Mounted TFK, SFH, 250A ACTFPKSF
31"W x 11.5"D 24 61.75 ACF3161S SFL, SFP
31"W x 11.5"D 27 65.875 ACF3165S Dual Mounted TQD, THQD 225A two-pole ACTFPKQD2P
31"W x 11.5"D 30 70 ACF3170S Dual Mounted TQD, THQD 225A three-pole ACTFPKQD3P
31"W x 11.5"D 33 74.125 ACF3174S Dual Mounted TJD, TJJ, TJK 400A ACTFPKJD
31"W x 11.5"D 36 78.25 ACF3178S Dual Mounted SGD, SGH, 400A, 600A ACTFPKSG
31"W x 11.5"D 39 82.275 ACF3182S SGL, SGP
31"W x 11.5"D 42 86.5 ACF3186S Single Mounted SGD, SGH, 400A, 800A ACSFPKSG
40"W x 11.5"D 15 49.375 ACF4049S SGL, SGP
40"W x 11.5"D 18 53.5 ACF4053S Single Mounted SKH, SKL 800A, 1200A ACSFPKSK
40"W x 11.5"D 21 57.625 ACF4057S Single Mounted TB4 400A ACSFPKTB4
40"W x 11.5"D 24 61.75 ACF4061S
40"W x 11.5"D 27 65.875 ACF4065S
40"W x 11.5"D 30 70 ACF4070S
40"W x 11.5"D 33 74.125 ACF4074S Mounting HardwareHardware to Mount One Breaker
40"W x 11.5"D 36 78.25 ACF4078S Maximum Breaker
40"W x 11.5"D 39 82.275 ACF4082S Mounting Breaker Breaker Number Product
40"W x 11.5"D 42 86.5 ACF4086S Arrangement Frame Amperage of Poles Number
Flush fronts (F) are 2 inches larger than box. Surface fronts (S) are 1/4-inch larger Dual Mounted SHE, SEL, 150A ACTHKSE
than box. SED, SEP
Dual Mounted TEB, TED, THED 150A single-pole ACTHKEB1P
Dual Mounted TEB, TED, THED 150A two-pole ACTHKEB2P
Dual Mounted TEB, TED, THED 150A three-pole ACTHKEB3P
Dual Mounted TFK, SFH, 250A ACTHKSF
SFL, SFP
Dual Mounted TQD, THQD 225A two-pole ACTHKQD2P
Dual Mounted TQD, THQD 225A three-pole ACTHKQD3P
Dual Mounted TJD, TJJ, TJK 400A ACTHKJD
Dual Mounted SGD, SGH, 400A, 600A ACTHKSG
SGL, SGP
Single Mounted SGD, SGH, 400A, 800A ACSHKSG
SGL, SGP
Single Mounted SKH, SKL 800A, 1200A ACSHKSK
Single Mounted TB4 400A ACSHKTB4
Note: If filler plates for SCP+ panels are required, please contact
Houston equipment plant.
Note: THLC 1/2/4 breaker no longer available.
Mounting HardwareCopper Straps for Use on Cu or Al Device and Hardware Suffix Selection
Main Bus Dual Mounted Device Type
Replacement Panelboard CCB Front (Flush or Surface) Replacement Panelboard CCB Box
Box Height Product Product
Box Width/Depth X Height (inches) Number1 Box Width/Depth X Height Box Height (inches) Number
31" Wide x 9 1/2" 15X 49 CBA3121S,F 31" Wide x 9 1/2" 15X 49 DASW3121
Deep Box (No Knockouts) Deep Box (No Knockouts)
31" Wide x 9 1/2" 18X 53 1/2 CBA3124S,F 31" Wide x 9 1/2" 21X 57 5/8 DASW3127
Deep Box (No Knockouts) Deep Box (No Knockouts)
31" Wide x 9 1/2" 21X 57 5/8 CBA3127S,F 31" Wide x 9 1/2" 24X 61 3/4 DASW3130
Deep Box (No Knockouts) Deep Box (No Knockouts)
31" Wide x 9 1/2" 24X 61 3/4 CBA3130S,F 31" Wide x 9 1/2" 27X 65 7/8 DASW3133
Deep Box (No Knockouts) Deep Box (No Knockouts)
31" Wide x 9 1/2" 30X 70 CBA3136S,F 31" Wide x 9 1/2" 30X 70 DASW3136
Deep Box (No Knockouts) Deep Box (No Knockouts)
31" Wide x 9 1/2" 42X 86 1/2 CBA3148S,F 31" Wide x 9 1/2" 36X 78 1/4 DASW3142
Deep Box (No Knockouts) Deep Box (No Knockouts)
35" Wide x 11 1/2" 36X 78 1/4 CBA3542S,F 35" Wide x 11 1/2" 33X 74 1/8 DACB3539
Deep Box (No Knockouts) Deep Box (No Knockouts)
40" Wide x 11 1/2" 21X 57 5/8 CBA4027S,F 35" Wide x 11 1/2" 39X 82 3/8 DACB3545
Deep Box (No Knockouts) Deep Box (No Knockouts)
40" Wide x 11 1/2" 24X 61 3/4 CBA4030S,F 40" Wide x 11 1/2" 21X 57 5/8 DACB4027
Deep Box (No Knockouts) Deep Box (No Knockouts)
40" Wide x 11 1/2" 30X 70 CBA4036S,F 40" Wide x 11 1/2" 24X 61 3/4 DACB4030
Deep Box (No Knockouts) Deep Box (No Knockouts)
40" Wide x 11 1/2" 33X 74 1/8 CBA4039S,F 40" Wide x 11 1/2" 27X 65 7/8 DACB4033
Deep Box (No Knockouts) Deep Box (No Knockouts)
40" Wide x 11 1/2" 36X 78 1/4 CBA4042S,F 40" Wide x 11 1/2" 30X 70 DACB4036
Deep Box (No Knockouts) Deep Box (No Knockouts)
40" Wide x 11 1/2" 39X 82 3/8 CBA4045S,F 40" Wide x 11 1/2" 33X 74 1/8 DACB4039
Deep Box (No Knockouts) Deep Box (No Knockouts)
1Flush fronts (F) are 2 inches larger than box. Surface fronts (S) are 1/4-inch larger 40" Wide x 11 1/2" 36X 78 1/4 DACB4042
than box. Deep Box (No Knockouts)
40" Wide x 11 1/2" 39X 82 3/8 DACB4045
Deep Box (No Knockouts)
40" Wide x 11 1/2" 42X 86 1/2 DACB4048
Deep Box (No Knockouts)
Note: Box dimensions are inside dimensions. Add 1/4-inch for outside dimensions.
Boxes furnished without knockouts as standard.
Filler Plates
Product
Panel Type X Height Number
QMR 1X QMRFP1
QMR 2X QMRFP2
QMR 5X QMRFP5
QMR 3X 75C145005G703
CCB 1X CCBFP1
CCB 3X CCBFP3
CCB 5X CCBFP5
CCB 2X 75C145005G711
CCB 6X 75C145005G715
SCP+ 1X SCPFP1
SCP+ 2X SCPFP2
SCP+ 3X SCPFP3
SCP+ 5X SCPFP5
QMR Mounting Hardware Kits Are Copper for Use with Maximum Horsepower Ratings QMR Fusible Switch
Cu or Al Main Bus Dual Mounted Vac Vdc
Available Publications
Spectra Series Power Panels Plug-In and Bolt-On Spectra Series Plug-In (Only) (continued)
Circuit Breaker Mounting Instructions (Modules) Installing Fusible Switches
TKM, THKM, TK4V, LA, SKPA GEH-5623 Fuse Pullers DEH-034
TJK, TJD, TJJ, THJK, TJ4V, THJ4V, TJL4V GEH-5624 Class R Fuse Rejector Kit GEH-4616
TEB, TED, THED, TEL, SEDA, SEHA, SELA, SEPA GEH-5625 R Fuse Rejection Pin, 400-600 Ampere Switch Units GEH-5577
TFJ, TFK, THFK, TFL, SFHA, SFLA, SEPA GEH-5626 Lug Kits into GE Type ADS Switches GEH-5944
TQD, THQD GEH-5643 Alternate Lugs, 30-1200 Ampere Fusible Switch Units GEJ-3050
THLC1 GEH-5644 Installing Fusible Switch Expansion Kits
SGDA, SGHA, SGLA, SGPA (3 pole) GEH-5673 30/60 Ampere Expansion Kit GEH-5547
SGDA, SGHA, SGLA, SGPA (2 pole) GEH-5674 60A, 100A Expansion Kits for Type ADS Fusible Switch Units GEH-5581
THLC2, THLC4, TLB4 (3 pole) GEH-5675 200 Ampere Expansion Kit (J, T Fuses) GEH-5582
THLC2, THLC4, TLB4 (2 pole) GEH-5676 200 Ampere Expansion Kit (H, K, R Fuses) GEH-5889
TEY, THQB, THHQB GEH-5677 Handle and Load Base Replacements on Fusible Switches
Circuit Breaker Mounting Hardware Kits Handle Replacement: 400-1200 Ampere Switches GEH-5553
TQD, THQD, SE TEB, TED, THED, THLC1, SF, TFJ, TFK, THFK, SG, Load Base Replacement for Type ADS 400-600 Ampere Switches GEH-5576
TJK, THJK, TJD, TJJ, THLC2, THLC4 GEH-5913
Miscellaneous
Installing Lugs Typical - Fusible Mains and Feeders DE-166
Type AML Main Lug Kits GEH-5588
Technical Data, Spectra Series Panelboards - Pressure Locked
Type AML Feed Thru Main Lug Kits GEH-5630 Connectors DE-168
Installing Fusible Switches
Fuse Pullers DEH-034
Class R Fuse Rejector Kit GEH-4616 Spectra Series Bolt-On (Only)
R Fuse Rejection Pin, 400-600 Ampere Switch Units GEH-5577 Circuit Breaker Mounting Instructions (Straps)
Lug Kits into GE Type ADS Switches GEH-5944 TEB, TED, THED, SED, SEH, SEL, SEP DEH-047
Alternate Lugs, 30-1200 Ampere Fusible Switch Units GEJ-3050 SGH, SFL, SFP DEH-059
30/60 Ampere Expansion Kit GEH-5547 SKH, SKL, SKP, TKM, THKM DEH-061
60A, 100A Expansion Kits for Type ADS Fusible Switch Units GEH-5581 TEY DEH-062
200 Ampere Expansion Kit (J, T Fuses) GEH-5582 TQD, THQD DEH-065
TJK, TJD, TJJ, THJK, TJ4V, THJ4V, TJL4V GEH-5624 Fact Sheet DET-398
NOTES:
Product Introduction
Evolution Series Switchboards offer a state-of-the-art design
that provides the high quality, safety and reliability long associ-
ated with GE group-mounted switchboards. Evolution Series
Switchboards are designed and manufactured to meet the
stringent GE internal standards along with NEMA, NEC, UL and
cUL requirements. In addition, Spectra RMS and Record Plus
Circuit Breakers meet all NEMA, NEC, IBC Seismic, UL and cUL
requirements, plus those for JIS and IEC.
Class 1
Class 2
Product Introduction
Spectra Series Switchboards offer a state-of-the-art design that
provides the high quality, safety and reliability long associated
with GE group-mounted switchboards. Spectra Series
Switchboards are designed and manufactured to meet the strin-
gent GE internal standards along with NEMA, NEC, UL and cUL
requirements. In addition, Spectra RMS and Record Plus Circuit
Breakers meet all NEMA, NEC, IBC Seismic, UL and cUL require-
ments, plus those for JIS and IEC.
Class 1
Class 2
Standards
Switchboard
UL 891
NEMA PB-2
Meter Sockets
UL 414
ANSI C12.7
Circuit Breakers
For application and size information, refer to publication
UL 489 DEA-552, www.geindustrial.com, or contact your local Sales Office.
Fused Switches
UL 98
Available Sections
Underground Pull Sections
Underground Pull Section with Main Switch
Underground Pull Section with Main Breaker
Overhead Sections with Main Switch or Breaker
CT Meter Sections with Main Switch
CT Meter Sections with Main Switch and Distribution
CT Meter Sections with Main Breaker
CT Main Sections with Main Breaker and Distribution
CT Meter Sections with Main Lugs
Auxiliary Sections (Wireways, Corner Sections)
Multi Meter Sections with Fusible Pullout Mains
Multi Meter Sections with Circuit Breaker Mains
Distribution Sections
Mounting holes
use four (18)
1/ -20 screws
Cover 4
Support
bracket
Meter socket
assembly
[1]
Meter Socket with Device Space Field Kit Meter Socket Space with Device Space Field Kit
Disconnect Rating Product Number Disconnect Rating Product Number
277/480V, 200A CM 203M SB600V 277/480V, 200A CM200A35K480V
35 kAIC Breaker 35 kAIC Breaker
277/480V, 100A CM 103M SB600V 277/480V, 100A CM100A35K480V
277/480V, 200A CM 203M SB600VH 277/480V, 200A CM200A65K480V
277/480V, 100A CM 103M SB600VH 277/480V, 100A CM100A65K480V
120/208V, 200A CM 203M SB240V 120/208V, 200A CM200A65K208V
65 kAIC Breaker 65 kAIC Breaker
120/208V, 100A CM 103M SB240V 120/208V, 100A CM100A65K208V
120/240V, 200A CM 203M SSB240V 120/240V, 200A CM200A65K240V
120/240V, 100A CM 103M SSB240V 120/240V, 100A CM100A65K240V
277/480V, 200A CM 203M STF600V 277/480V, 200A CM200ATF280V
T-Fuse Pullout 120/208V, 200A CM 203M STF240V T-Fuse Pullout 120/208V, 200A CM200ATF208V
120/240V, 200A CM 201M STF240V 120/240V, 200A CM200ATF240V
277/480V, 200A CM 200M SJF600V
FD1 Switch
120/480V, 100A CM 200M SJF240V Notes:
- Small tenant spaces do not get a meter socket nor any wiring
- Provisions do not get a meter socket but they do get wiring
Product Introduction
Spectra Integrated Switchboard solutions save time, money
and space, yet sacrifice nothing in terms of safety, performance
or flexibility. You get flexibility in design and consistency in exe-
cution. Units expand or contract to accommodate your specific
needs. And not only do they reflect GEs rigorous Six Sigma quali-
ty standards, they are also built and tested in accordance with
NEMA PB-2, UL 891 and the NEC. All sections and devices are UL
listed and UL labeled.
Features
Spectra Integrated Switchboard solutions are custom designed Typical Installation Steps for Spectra Integrated
and built to your specifications. You choose all the elements you Switchboard Solution
need. Featured elements include: 1. Bring conduits through floor
Power distribution 2. Receive single units from switchboard lineup
Energy management systems 3. Set switchboard in place (whether the room is complete or not)
Building automation systems 4. Run conduits and wire branches
Surge suppression
Dry type transformers
Lighting controls
Benefits
Save SpaceConventional electrical installations waste space.
Lighting and power panels take up long stretches of wall.
Transformers eat up floor space. Lighting controls and building
automation have to go somewhere. Spectra Integrated
Switchboard solutions integrate all these elements into a frac-
tion of the area.
Reduce Total Installed CostsThe Spectra Integrated
Switchboard solution packs virtually all your power require-
ments into one single integrated distribution and control
systema compact, plug-and-play line-up. This reduces instal-
lation costs while turning otherwise non-productive
mechanical space into revenue-generating sales or storage
space.
Cut Installation TimeConstruction schedules have never
been tighter. When youre ready to install electrical equipment,
you want it done now, so that you can move on to the next
step. Spectra Integrated Switchboard solutions arrive with
everything you need, and when you need it, fully pre-wired to
your specifications. All you have to do is set it in place, run the
incoming power and wire out the branches. Installation takes
less than half the time.
To determine A-Series Panel height (AQ, AL and AE only), refer to EQIP Sizing 2001.
Hinged covers for lighting panels are available, ask local GE Sales Office
40" Max.
A-Series Panel Selection Guide
UL
Amps. Max. Service Information Switchboard Location Section Width Min.
4
AQ panel X
125 A 240 Vac max. Top, Bottom 20W
225 A 1 Ph, 3W. Top, Bottom 20W
400 A 3 Ph, 3W. Top, Bottom 20W
AL panel
125 A 240 Vac max. Top, Bottom 20W
225 A 1 Ph, 3W. Top, Bottom 20W
400 A 3 Ph, 3W. Top, Bottom 20W
AE Panel
125 A 480Y/227 Vac Top, Bottom 20W 37
40 90
225 A 3 Ph, 4W. Top, Bottom 20W
400 A 125/250 Vdc Top, Bottom 20W 4
AD Panel1 X
125 A 120/208 Vac, 3 Ph, 4W. Full Height 25W
225 A 480 Vac, 3 Ph, 3W. Full Height 25W
400 A 480Y/277 Vac, 3 Ph, 4W. Full Height 25W
1Availability limited, ask local GE Sales Office
600 A available, ask local GE Sales Office
31
36
X
Transformer Specifications
40" Max.
Type 3 Phase, 15-225 kVA
High-Efficiency UL
Windings Copper or Aluminum
Temp. Rise 80C, 115C, 150C
Category Standard
Shield No shield or Electrostatic-Shield1
Enclosure Type NEMA 12
24
No transformer can be placed in a section adjacent to a 150 kVA or 225 kVA
Individual transformers can be placed at the bottom of the section only.
1K-rated transformer, low noise and ultra efficient are also available.
Confirm requirements with local GE Sales Ofice
2N3R available up to 45 kVA max
24
Individual Mounting Logic
ISB Section Size kVA3 XF Frame Size4
30 Wide X 25 Deep 15-45 71, 72, 73, 31, 32, 33
35 Wide X 30 Deep 75-150 74, 75, 34, 35, FC77 XFMR 36
150 KVA Max.
40 Wide X 30 Deep 112.5-225 76, 77, 36, 37
3kVA rangle overlaps due to temp rise, confirm requirements with speedi or in Section 10 of the BuyLog
4Refer to Section 10 of the BuyLog or speedi for more information
36
X
Individual Transformer
42
42
XFMR
112.5 KVA Max.
42
X
Dual Transformer
Product Description
Panel type AQ, AL, AE
Panel height 37"H with MCB
Transformer type High-Efficiency, 3 Phase, 15 - 150 kVA
Section size In individual mounting, section depth and width
depend on the transformer.
In double mounting, minimum section width is 40W.
Section depth depends on the transformer.
UL UL
4 4
X X X
31
37 40 37
40
4 4
XFMR XFMR
Max. 150 kVA Max. 150 kVA
36 36
X X
A-Series Single Mounting and Transformer A-Series Double Mounting and Transformer
Breaker Specifications
Type Spectra RMS SE
Spectra RMS SF
Ampere Rating SE 15-150
SF 70-250
System 3Ph, 3W
3Ph, 4W
Voltage 480 V max.
Section depth 15" min.
Stack with Transformers
Lighting panels
When SE/SF are mounting in stack with transformers, the section size depend on the transformers.
SE/SF individually mounted circuit breakers available, ask local GE Sales Office.
Breaker Dimensions
Minimum size into the section
Type Ampere Rating Height Width
SE 15-70 8H 20W
SE 70-150 8H 20W
SF 70-150 8H 20W
SF 150-250 8H 25W
UL UL
16
16
31
DIST 36
DIST
8
DP-T3
SF
8
8
4
X
XFMR
150 KVA
31
36 36
X X
The minimum section depth required to mount a 463, 260L, or 360ML2 is 15"D.
All other contactors require 20"D section.
Total Box size includes the size of the contactor and necessary wire bending space
required. Contactors are placed at the bottom of the section.
Lighting Contactors
Type: Amps- Valid Section Section Contactor Module UL
Contactor Contactor Combinations Width Depth Width Height
X
CR360L3 30 CR360L3, L4 20-40 15 - 30 5.00 8.58
CR360L4 60 CR360L3, L4 20-40 20 - 30 5.00 10.70
CR463ML 30 CR463ML 20-40 15 - 30 6.66 10.70
CR360L5 100 CR360L5 20-40 20 - 30 7.50 17.45
CR360L6 200 CR360ML400, CR36L6, L7 20-40 25 - 30 11.65 25.74
CR360L7 300 CR360ML400, CR36L6, L7 20-40 25 - 30 12.50 34.90
CR360ML400 400 CR360ML400, CR36L6, L7 20-40 25- 30 12.25 26.90
CR160MC30 30 20-40 20 - 30 10.00 14.30
CR160MC60-75 60-75 CR160MC30, MC60-75, 20-40 20 - 30 10.00 17.45 31
CR160MC100 100 MC100, MC150, 20-40 20 - 30 10.00 19.31 36
CR160MC150 150 MC200, MC225 20-40 20 - 30 10.00 24.50
CR160MC200 200 20-40 20 - 30 10.00 25.70
CR160MC225 225 20-40 20 - 30 10.00 26.90
External ROCB
Controller N/A External ROCB Controller 20-40 20 - 30 10 28
CONTACTORS
WIRING SPACE
CR463 CR463
WIRING SPACE
LIGHTING LIGHTING
CONTACTOR CONTACTOR
Additional Options
8 POLE 8 POLE
Automatic Transfer Switches - 200A or less
20
Product Introduction
For customers who wish to provide their facility with power assurance in
the event of a utility failure or onsite generator failure, the new GE
GenTower offers a stand alone, permanent solution. It provides end cus-
tomers the ability to easily connect a mobile generator to feed the main
power distribution system in the event of a total power failure. Because
the board is permanently installed to the system, there is no need to
make emergency modifications to the building or main distribution board
to connect a generator during the crisis or outage. This saves the build-
ing owner both labor costs and costs associated with down time
at the facility.
Primary Features
Switchboard Styled NEMA Type 1 Indoor or NEMA 3R Enclosure
1000A Heat Rated Bus Max. 100kAIC @ 480V Max.
Ground Fault Protection Optional
Left or Right Hand Pull Sections
Top or Bottom Feed
UL, EUSERC Approved
14X, 18X, 23X of Device Space for Feeder Breakers,
Bolt-on Construction
Seismic IBC Zone 4, CBC Zone 4, UBC Zone 4
Heat Rated Copper Bus
Accepts Aluminum or Copper Incoming Cable
35"W Bolt-on (45"W Plug-in) x 90"H x 25"D (Main Only)
35"W x 90"H x 25"D (Bussed Pull Section)
Add 11" Depth for NEMA 3R
Instructions
Drawings Included (Feed to Right STD)
Be sure Utility Kit Size matches Distribution Section
Breaker Distribution Section 35"W
Breaker Distribution Service Disconnect only
Main Device available on next page
18X Spectra Interior available for Distribution
Product Introduction
The GE Jiffy III Utility Service Entrance Switchboard is designed
especially to address the Canadian market. The compact unit
combines the electrical distribution panel, the main service
disconnect and the utility metering compartment into one
space-saving unit, delivering maximum installation opportunities.
The switchboard is floor mounted and rated up to a maximum
1200A, 42 kAIC @600V. At 15 (381 mm) deep, the electrical
distribution board easily fits into the tightest areas where space
is typically limited. The Jiffy III is UL and cUL1 approved and
meets the seismic requirements of IBC Zone 4 and CBC Zone 4.
Designed and approved specifically for the Canadian Utility
Market 2, the Jiffy III is available with mains rated at 800A, 1000A
and 1200A; 80% and 100% rated (with the exception of 1200A,
which is 80% rated only); and with or without Ground Fault pro-
tection. A full line of field installable Digital Solid State Electronic
Trip Molded-Case Breakers is also available. With a combination
of superior features and options, the GE Jiffy III Utility Service
Entrance Switchboard not only meets your space-saving needs,
but also offers total flexibility in design to meet the requirements
of the project.
Features
Switchboard Styled, Type 1 Indoor Enclosure with Driphood
(NEMA 1)
1200AHeat Rated Bus max., 65kAIC @ 600V max.
80% and 100% Rated Main (1200A rated at 80% only)
Ground Fault Protection optional
Left or Right Hand Pull Sectionsdependent on region
Top or Bottom Feed Maindependent on region
UL, cUL approved
23X of Device Space for Feeder Breakers, Bolt-on Construction
Seismic IBC Zone 4, CBC Zone 4, UBC Zone 4
Heat Rated Aluminum Bus Bar standard with Copper Main
Device Straps
Accepts Aluminum or Copper Incoming Cable
40 W (1016 mm) x 90 H (2286 mm) x 15 D (381 mm)
(Main Only)
25 W (635 mm) x 90 H (2286 mm) x 15 D (381 mm)
(Bussed Pull Section)
15 W (381 mm) x 90 H (2286 mm) x 15 D (381 mm)
(Blank Pull Section)
Branch FeedMCCB 15-1200A
1cUL certified to meet CSA 22.2 No. 31.
2Non-BC Hydro Utilities. Contact your local GE Sales Engineer for your
utility requirements.
Switchboard with Bussed Section1Left to Right Feed Switchboard w/out Bussed Pull Section1Top Feed
Max. Main Breaker Ground Fault Product Max. Main Breaker Ground Fault Product
Amp Rating Protection Number Amp Rating Protection Number
800 80% No ACJ208080LR 800 80% No ACJ108080T
800 80% Yes ACJ208080GLR 800 80% Yes ACJ108080GT
800 100% No ACJ208100LR 800 100% No ACJ108100T
800 100% Yes ACJ208100GLR 800 100% Yes ACJ108100GT
1000 100% No ACJ210100LR 1000 100% No ACJ110100T
1000 100% Yes ACJ210100GLR 1000 100% Yes ACJ110100GT
1200 80% No ACJ212080LR 1200 80% No ACJ112080T
1200 80% Yes ACJ212080GLR 1200 80% Yes ACJ112080GT
Switchboard with Bussed Section1Right to Left Feed Switchboard w/out Bussed Pull Section1Bottom Feed
Max. Main Breaker Ground Fault Product Max. Main Breaker Ground Fault Product
Amp Rating Protection Number Amp Rating Protection Number
800 80% No ACJ208080RL 800 80% No ACJ108080B
800 80% Yes ACJ208080GRL 800 80% Yes ACJ108080GB
800 100% No ACJ208100RL 800 100% No ACJ108100B
800 100% Yes ACJ208100GRL 800 100% Yes ACJ108100GB
1000 100% No ACJ210100RL 1000 100% No ACJ110100B
1000 100% Yes ACJ210100GRL 1000 100% Yes ACJ110100GB
1200 80% No ACJ212080RL 1200 80% No ACJ112080B
1200 80% Yes ACJ212080GRL 1200 80% Yes ACJ112080GB
1Bus materialaluminum with copper main device straps. Bussed pull sections are
not convertible from left to right or right to left. Main breaker included in section.
Specifications
Product Capability/Specification Jiffy III Switchboard Additional Information
Enclosure Type NEMA 1 NEMA 1 with Driphood
Section Dimensions 40 W x 90 H x 15 D (1016 mm x 2286 mm x 381 mm) (Main Only)
25 W x 90 H x 15 D (635 mm x 2286 mm x 381 mm) (Bussed Pull Section)
15 W x 90 H x 15 D (381 mm x 2286 mm x 381 mm) (Blank Pull Section)
Voltage 600V Max.
Amperage 1200A - Heat Rated
Bus Bar Aluminum with Copper Main Device Straps
80% Rating 800A to 1200A
100% Rating 800A to 1000A
Standards cUL, NEMA, NEC, PB II
Seismic Rating IBC Zone 4, CBC Zone 4, UBC Zone 4
Entry Cable or Bussed Pull Section
Top or Bottom Feed Top and Bottom Feed
Lug Type Mechanical Aluminum
Incoming Cable Copper or Aluminum
Max. Bus kA Rating 65kAIC
Neutral Rating 100% - Heat Rated
Main Devices 1200A
Manually Operated
Stationary
Main Device Accessories UV2, ST2, Aux Contact, Bell Alarm Field Installed
Utility CT Provision Bar Type CT
Utility PT Provision Yes
Branch/Feeder Switches MCCB 15 1200A TEY, TED, TED6CL, THED, TEDL, SFHA
SGLA, SFDA, SFHA, SKHA, SKLA
Field Installed
Branch Accessories UV2, ST2, Aux Contact, Bell Alarm Field Installed
Branch Mounting 23x Bolt-on Construction
Delivery Time 2 Weeks to Ship - 3 Weeks On-site
Accessories Available Jiffy and Spectra Bolt-on Device Mounting Hardware
Full Filler Plates for Jiffy and Spectra
Jiffy and Spectra Bolt-on Device Filler Plate Kit
Padlocking Devices for Jiffy and Spectra
Load Lugs
2Shunt Trip or UV cannot be installed in same breakers.
DNSP(Call GE EnergySales Office The short-circuit rating of a busway plug is equal to the short-cir-
for information.) cuit rating of the fuse or circuit breaker used in the plug.
Thermal Expansion
Give consideration to the effects of thermal expansion on
busway runs. Compensation for thermal expansion is inherent in
DH busway. For other busway types, expansion fittings may be
necessary for long straight runs of 150 feet or more, particularly
if the busway is not free to move at the ends of the run. The use
of an expansion fitting is recommended when the busway run
crosses a building expansion joint.
Fusible Switch Busway Plugs Spectra RMS Circuit Breaker IC Ratings (rms sym. kA)
Frame Type 240 V 480 V 600 V
Fusible switches in all busway fittings (plugs, power takeoffs, and
SED 18 14 14
reducers) have the following short-circuit ratings when used with
SEH 65 25 18
the fuses shown. To qualify for R fuse rating, switches must have SEL 100 65 25
R fuse clips which reject other type fuses. The interrupting rating SEP 200 100 25
SFH 65 25 18
of the fuse must equal or exceed the short-circuit rating of the SFL 100 65 25
switch. It is lower than the short-circuit rating of the switch, then SFP 200 100 25
the combination has the rating of the fuse. SGH4 65 35 25
SGL4 100 65 65
SGP4 200 100 65
Switch Interrupting Rating SGH6 65 35 25
Switch Ampere Fuse Amperes rms Symmetrical SGL6 100 65 65
Type Rating UL Class Description 240 and 480 Volts SGP6 200 100 65
QMR 30 to 1200 H One Time 10,000 SKH 65 50 25
QMR 30 to 1200 K5 High Interrupting 10,000 SKL 100 65 42
QMR 30 to 1200 K1 High Interrupting 10,000 SKP 200 100 65
QMR 30 to 1200 J Current Limiting 200,000
QMR 30 to 1200 R Current Limiting 200,000
QMR 30 to 1200 L Current Limiting 200,000
Floor 1. With initial busway purchase. Use the product numbers listed
above and the fire-stop material will be shipped in a specially
marked box directly to the job site with the busway.
Mineral Wool 2. Through 1-800-GE 1-STOP or an authorized GE Silicones
Concrete 4 " 3" Depth Minimum Distributor. Recommended for fill-in (if needed) after
Thick Minimum initial purchase.
This information is provided as a guideline for typical fire-stop
Note: The Busway cover plate and sealant is required on both sides for wall
installation.
systems. If you have an annulus (or opening) greater than 1
beyond the busway enclosure, you will need to determine the
proper amount of fire-stop material based on the illustration on
this page. Quantities are based on application of recommended
amount of material; more may be required if over-application
occurs.
F 3 H A 02 SL I 02
Product Description Code
Feeder F
Type Plug-In 5 P Type Feet Code 6
Riser 5 R 1 01
3PH, 3W 3 2 02
Service 3PH, 4W 4 3 03
100% Neutral
Ground Integrated Housing H 4 04
Copper C Indoor I 5 05
Conductor Feeder
Aluminum A Drip Proof D 0 06
Splash Proof S 7 07
Outdoor O 8 08
Amps Code 9 09
Configurations Code 225 02 10 10
Straight Length SL 400 04 1 01
Elbow Left EL 600 06 2 02
Elbow Right ER 800 08 4 04
Plug-In
Elbow Up EU 1000 10 6 06
Elbow Down ED 1200 12 8 08
Center Cable Tap Box-Up CT 1350 13 10 10
Center Cable Tap Box-Down CB 1600 16 Fittings NA ST
End Cable Tap Box-Up TT 2000 20
End Cable Tap Box-Down TB 2500 25
End Box EB 3000 30
Flanged End FE 4000 40
Flanged End w/Lugs FL
5 Straight lengths only.
6 Code 01 suffix for order entry purposes only. Minimum length 2'-0".
225 Amps Three-Phase, Three-Wire Internal Ground Bar 800 Amps Three-Phase, Three-Wire Internal Ground Bar
Component Type Product Number Component Type Product Number
Linear Lengths 10-ft. plug-in P3GC02SLI10 Linear Lengths 10-ft. plug-in P3GC08SLI10
Linear Lengths 10-ft. feeder F3GC02SLI10 Linear Lengths 10-ft. feeder F3GC08SLI10
Linear Lengths 10-ft. riser R3GC02SLI10 Linear Lengths 10-ft. riser R3GC08SLI10
Fitting Elbows; Left F3GC02ELIST Fitting Elbows; Left F3GC08ELIST
Fitting Elbows; Right F3GC02ERIST Fitting Elbows; Right F3GC08ERIST
Fitting Elbows; Up F3GC02EUIST Fitting Elbows; Up F3GC08EUIST
Fitting Elbows; Down F3GC02EDIST Fitting Elbows; Down F3GC08EDIST
Accessories End Cable Tap Box (Up) F3GC02TTIST Accessories End Cable Tap Box (Up) F3GC08TTIST
Accessories End Cable Tap Box (Dn) F3GC02TBIST Accessories End Cable Tap Box (Dn) F3GC08TBIST
Accessories Center Cable Tap Box (Up) F3GC02CTIST Accessories Center Cable Tap Box (Up) F3GC08CTIST
Accessories Center Cable Tap Box (Dn) F3GC02CBIST Accessories Center Cable Tap Box (Dn) F3GC08CBIST
Accessories End Box F3GC02EBIST Accessories End Box F3GC08EBIST
Accessories Flanged End w/ Lugs F3GC02FLIST Accessories Flanged End w/ Lugs F3GC08FLIST
Accessories Flanged End F3GC02FEIST Accessories Flanged End F3GC08FEIST
400 Amps Three-Phase, Three-Wire Internal Ground Bar 1000 Amps Three-Phase, Three-Wire Internal Ground Bar
Component Type Product Number Component Type Product Number
Linear Lengths 10-ft. plug-in P3GC04SLI10 Linear Lengths 10-ft. plug-in P3GC10SLI10
Linear Lengths 10-ft. feeder F3GC04SLI10 Linear Lengths 10-ft. feeder F3GC10SLI10
Linear Lengths 10-ft. riser R3GC04SLI10 Linear Lengths 10-ft. riser R3GC10SLI10
Fitting Elbows; Left F3GC04ELIST Fitting Elbows; Left F3GC10ELIST
Fitting Elbows; Right F3GC04ERIST Fitting Elbows; Right F3GC10ERIST
Fitting Elbows; Up F3GC04EUIST Fitting Elbows; Up F3GC10EUIST
Fitting Elbows; Down F3GC04EDIST Fitting Elbows; Down F3GC10EDIST
Accessories End Cable Tap Box (Up) F3GC04TTIST Accessories End Cable Tap Box (Up) F3GC10TTIST
Accessories End Cable Tap Box (Dn) F3GC04TBIST Accessories End Cable Tap Box (Dn) F3GC10TBIST
Accessories Center Cable Tap Box (Up) F3GC04CTIST Accessories Center Cable Tap Box (Up) F3GC10CTIST
Accessories Center Cable Tap Box (Dn) F3GC04CBIST Accessories Center Cable Tap Box (Dn) F3GC10CBIST
Accessories End Box F3GC04EBIST Accessories End Box F3GC10EBIST
Accessories Flanged End w/ Lugs F3GC04FLIST Accessories Flanged End w/ Lugs F3GC10FLIST
Accessories Flanged End F3GC04FEIST Accessories Flanged End F3GC10FEIST
600 Amps Three-Phase, Three-Wire Internal Ground Bar 1200 Amps Three-Phase, Three-Wire Internal Ground Bar
Component Type Product Number Component Type Product Number
Linear Lengths 10-ft. plug-in P3GC06SLI10 Linear Lengths 10-ft. plug-in P3GC12SLI10
Linear Lengths 10-ft. feeder F3GC06SLI10 Linear Lengths 10-ft. feeder F3GC12SLI10
Linear Lengths 10-ft. riser R3GC06SLI10 Linear Lengths 10-ft. riser R3GC12SLI10
Fitting Elbows; Left F3GC06ELIST Fitting Elbows; Left F3GC12ELIST
Fitting Elbows; Right F3GC06ERIST Fitting Elbows; Right F3GC12ERIST
Fitting Elbows; Up F3GC06EUIST Fitting Elbows; Up F3GC12EUIST
Fitting Elbows; Down F3GC06EDIST Fitting Elbows; Down F3GC12EDIST
Accessories End Cable Tap Box (Up) F3GC06TTIST Accessories End Cable Tap Box (Up) F3GC12TTIST
Accessories End Cable Tap Box (Dn) F3GC06TBIST Accessories End Cable Tap Box (Dn) F3GC12TBIST
Accessories Center Cable Tap Box (Up) F3GC06CTIST Accessories Center Cable Tap Box (Up) F3GC12CTIST
Accessories Center Cable Tap Box (Dn) F3GC06CBIST Accessories Center Cable Tap Box (Dn) F3GC12CBIST
Accessories End Box F3GC06EBIST Accessories End Box F3GC12EBIST
Accessories Flanged End w/ Lugs F3GC06FLIST Accessories Flanged End w/ Lugs F3GC12FLIST
Accessories Flanged End F3GC06FEIST Accessories Flanged End F3GC12FEIST
1600 Amps Three-Phase, Three-Wire Internal Ground Bar 3000 Amps Three-Phase, Three-Wire Internal Ground Bar
Component Type Product Number Component Type Product Number
Linear Lengths 10-ft. plug-in P3GC16SLI10 Linear Lengths 10-ft. plug-in P3GC30SLI10
Linear Lengths 10-ft. feeder F3GC16SLI10 Linear Lengths 10-ft. feeder F3GC30SLI10
Linear Lengths 10-ft. riser R3GC16SLI10 Linear Lengths 10-ft. riser R3GC30SLI10
Fitting Elbows; Left F3GC16ELIST Fitting Elbows; Left F3GC30ELIST
Fitting Elbows; Right F3GC16ERIST Fitting Elbows; Right F3GC30ERIST
Fitting Elbows; Up F3GC16EUIST Fitting Elbows; Up F3GC30EUIST
Fitting Elbows; Down F3GC16EDIST Fitting Elbows; Down F3GC30EDIST
Accessories End Cable Tap Box (Up) F3GC16TTIST Accessories End Cable Tap Box (Up) F3GC30TTIST
Accessories End Cable Tap Box (Dn) F3GC16TBIST Accessories End Cable Tap Box (Dn) F3GC30TBIST
Accessories Center Cable Tap Box (Up) F3GC16CTIST Accessories Center Cable Tap Box (Up) F3GC30CTIST
Accessories Center Cable Tap Box (Dn) F3GC16CBIST Accessories Center Cable Tap Box (Dn) F3GC30CBIST
Accessories End Box F3GC16EBIST Accessories End Box F3GC30EBIST
Accessories Flanged End w/ Lugs F3GC16FLIST Accessories Flanged End w/ Lugs F3GC30FLIST
Accessories Flanged End F3GC16FEIST Accessories Flanged End F3GC30FEIST
2000 Amps Three-Phase, Three-Wire Internal Ground Bar 4000 Amps Three-Phase, Three-Wire Internal Ground Bar
Component Type Product Number Component Type Product Number
Linear Lengths 10-ft. plug-in P3GC20SLI10 Linear Lengths 10-ft. plug-in P3GC40SLI10
Linear Lengths 10-ft. feeder F3GC20SLI10 Linear Lengths 10-ft. feeder F3GC40SLI10
Linear Lengths 10-ft. riser R3GC20SLI10 Linear Lengths 10-ft. riser R3GC40SLI10
Fitting Elbows; Left F3GC20ELIST Fitting Elbows; Left F3GC40ELIST
Fitting Elbows; Right F3GC20ERIST Fitting Elbows; Right F3GC40ERIST
Fitting Elbows; Up F3GC20EUIST Fitting Elbows; Up F3GC40EUIST
Fitting Elbows; Down F3GC20EDIST Fitting Elbows; Down F3GC40EDIST
Accessories End Cable Tap Box (Up) F3GC20TTIST Accessories End Cable Tap Box (Up) F3GC40TTIST
Accessories End Cable Tap Box (Dn) F3GC20TBIST Accessories End Cable Tap Box (Dn) F3GC40TBIST
Accessories Center Cable Tap Box (Up) F3GC20CTIST Accessories Center Cable Tap Box (Up) F3GC40CTIST
Accessories Center Cable Tap Box (Dn) F3GC20CBIST Accessories Center Cable Tap Box (Dn) F3GC40CBIST
Accessories End Box F3GC20EBIST Accessories End Box F3GC40EBIST
Accessories Flanged End w/ Lugs F3GC20FLIST Accessories Flanged End w/ Lugs F3GC40FLIST
Accessories Flanged End F3GC20FEIST Accessories Flanged End F3GC40FEIST
225 Amps Three-Phase, Four-Wire Internal Ground Bar 800 Amps Three-Phase, Four-Wire Internal Ground Bar
Component Type Product Number Component Type Product Number
Linear Lengths 10-ft. plug-in P4GC02SLI10 Linear Lengths 10-ft. plug-in P4GC08SLI10
Linear Lengths 10-ft. feeder F4GC02SLI10 Linear Lengths 10-ft. feeder F4GC08SLI10
Linear Lengths 10-ft. riser R4GC02SLI10 Linear Lengths 10-ft. riser R4GC08SLI10
Fitting Elbows; Left F4GC02ELIST Fitting Elbows; Left F4GC08ELIST
Fitting Elbows; Right F4GC02ERIST Fitting Elbows; Right F4GC08ERIST
Fitting Elbows; Up F4GC02EUIST Fitting Elbows; Up F4GC08EUIST
Fitting Elbows; Down F4GC02EDIST Fitting Elbows; Down F4GC08EDIST
Accessories End Cable Tap Box (Up) F4GC02TTIST Accessories End Cable Tap Box (Up) F4GC08TTIST
Accessories End Cable Tap Box (Dn) F4GC02TBIST Accessories End Cable Tap Box (Dn) F4GC08TBIST
Accessories Center Cable Tap Box (Up) F4GC02CTIST Accessories Center Cable Tap Box (Up) F4GC08CTIST
Accessories Center Cable Tap Box (Dn) F4GC02CBIST Accessories Center Cable Tap Box (Dn) F4GC08CBIST
Accessories End Box F4GC02EBIST Accessories End Box F4GC08EBIST
Accessories Flanged End w/ Lugs F4GC02FLIST Accessories Flanged End w/ Lugs F4GC08FLIST
Accessories Flanged End F4GC02FEIST Accessories Flanged End F4GC08FEIST
400 Amps Three-Phase, Four-Wire Internal Ground Bar 1000 Amps Three-Phase, Four-Wire Internal Ground Bar
Component Type Product Number Component Type Product Number
Linear Lengths 10-ft. plug-in P4GC04SLI10 Linear Lengths 10-ft. plug-in PAGC10SLI10
Linear Lengths 10-ft. feeder F4GC04SLI10 Linear Lengths 10-ft. feeder F4GC10SLI10
Linear Lengths 10-ft. riser R4GC04SLI10 Linear Lengths 10-ft. riser R4GC10SLI10
Fitting Elbows; Left F4GC04ELIST Fitting Elbows; Left F4GC10ELIST
Fitting Elbows; Right F4GC04ERIST Fitting Elbows; Right F4GC10ERIST
Fitting Elbows; Up F4GC04EUIST Fitting Elbows; Up F4GC10EUIST
Fitting Elbows; Down F4GC04EDIST Fitting Elbows; Down F4GC10EDIST
Accessories End Cable Tap Box (Up) F4GC04TTIST Accessories End Cable Tap Box (Up) F4GC10TTIST
Accessories End Cable Tap Box (Dn) F4GC04TBIST Accessories End Cable Tap Box (Dn) F4GC10TBIST
Accessories Center Cable Tap Box (Up) F4GC04CTIST Accessories Center Cable Tap Box (Up) F4GC10CTIST
Accessories Center Cable Tap Box (Dn) F4GC04CBIS Accessories Center Cable Tap Box (Dn) F4GC10CBIST
Accessories End Box F4GC04EBIST Accessories End Box F4GC10EBIST
Accessories Flanged End w/ Lugs F4GC04FLIST Accessories Flanged End w/ Lugs F4GC10FLIST
Accessories Flanged End F4GC04FEIST Accessories Flanged End F4GC10FEIST
600 Amps Three-Phase, Four-Wire Internal Ground Bar 1200 Amps Three-Phase, Four-Wire Internal Ground Bar
Component Type Product Number Component Type Product Number
Linear Lengths 10-ft. plug-in P4GC06SLI10 Linear Lengths 10-ft. plug-in P4GC12SLI10
Linear Lengths 10-ft. feeder F4GC06SLI10 Linear Lengths 10-ft. feeder F4GC12SLI10
Linear Lengths 10-ft. riser R4GC06SLI10 Linear Lengths 10-ft. riser R4GC12SLI10
Fitting Elbows; Left F4GC06ELIST Fitting Elbows; Left F4GC12ELIST
Fitting Elbows; Right F4GC06ERIST Fitting Elbows; Right F4GC12ERIST
Fitting Elbows; Up F4GC06EUIST Fitting Elbows; Up F4GC12EUIST
Fitting Elbows; Down F4GC06EDIST Fitting Elbows; Down F4GC12EDIST
Accessories End Cable Tap Box (Up) F4GC06TTIST Accessories End Cable Tap Box (Up) F4GC12TTIST
Accessories End Cable Tap Box (Dn) F4GC06TBIST Accessories End Cable Tap Box (Dn) F4GC12TBIST
Accessories Center Cable Tap Box (Up) F4GC06CTIST Accessories Center Cable Tap Box (Up) F4GC12CTIST
Accessories Center Cable Tap Box (Dn) F4GC06CBIST Accessories Center Cable Tap Box (Dn) F4GC12CBIST
Accessories End Box F4GC06EBIST Accessories End Box F4GC12EBIST
Accessories Flanged End w/ Lugs F4GC06FLIST Accessories Flanged End w/ Lugs F4GC12FLIST
Accessories Flanged End F4GC06FEIST Accessories Flanged End F4GC12FEIST
1600 Amps Three-Phase, Four-Wire Internal Ground Bar 3000 Amps Three-Phase, Four-Wire Internal Ground Bar
Component Type Product Number Component Type Product Number
Linear Lengths 10-ft. plug-in P4GC16SLI10 Linear Lengths 10-ft. plug-in P4GC30SLI10
Linear Lengths 10-ft. feeder F4GC16SLI10 Linear Lengths 10-ft. feeder F4GC30SLI10
Linear Lengths 10-ft. riser R4GC16SLI10 Linear Lengths 10-ft. riser R4GC30SLI10
Fitting Elbows; Left F4GC16ELIST Fitting Elbows; Left F4GC30ELIST
Fitting Elbows; Right F4GC16ERIST Fitting Elbows; Right F4GC30ERIST
Fitting Elbows; Up F4GC16EUIST Fitting Elbows; Up F4GC30EUIST
Fitting Elbows; Down F4GC16EDIST Fitting Elbows; Down F4GC30EDIST
Accessories End Cable Tap Box (Up) F4GC16TTIST Accessories End Cable Tap Box (Up) F4GC30TTIST
Accessories End Cable Tap Box (Dn) F4GC16TBIST Accessories End Cable Tap Box (Dn) F4GC30TBIST
Accessories Center Cable Tap Box (Up) F4GC16CTIST Accessories Center Cable Tap Box (Up) F4GC30CTIST
Accessories Center Cable Tap Box (Dn) F4GC16CBIST Accessories Center Cable Tap Box (Dn) F4GC30CBIST
Accessories End Box F4GC16EBIST Accessories End Box F4GC30EBIST
Accessories Flanged End w/ Lugs F4GC16FLIST Accessories Flanged End w/ Lugs F4GC30FLIST
Accessories Flanged End F4GC16FEIST Accessories Flanged End F4GC30FEIST
2000 Amps Three-Phase, Four-Wire Internal Ground Bar 4000 Amps Three-Phase, Four-Wire Internal Ground Bar
Component Type Product Number Component Type Product Number
Linear Lengths 10-ft. plug-in P4GC20SLI10 Linear Lengths 10-ft. plug-in P4GC40SLI10
Linear Lengths 10-ft. feeder F4GC20SLI10 Linear Lengths 10-ft. feeder F4GC40SLI10
Linear Lengths 10-ft. riser R4GC20SLI10 Linear Lengths 10-ft. riser R4GC40SLI10
Fitting Elbows; Left F4GC20ELIST Fitting Elbows; Left F4GC40ELIST
Fitting Elbows; Right F4GC20ERIST Fitting Elbows; Right F4GC40ERIST
Fitting Elbows; Up F4GC20EUIST Fitting Elbows; Up F4GC40EUIST
Fitting Elbows; Down F4GC20EDIST Fitting Elbows; Down F4GC40EDIST
Accessories End Cable Tap Box (Up) F4GC20TTIST Accessories End Cable Tap Box (Up) F4GC40TTIST
Accessories End Cable Tap Box (Dn) F4GC20TBIST Accessories End Cable Tap Box (Dn) F4GC40TBIST
Accessories Center Cable Tap Box (Up) F4GC20CTIST Accessories Center Cable Tap Box (Up) F4GC40CTIST
Accessories Center Cable Tap Box (Dn) F4GC20CBIST Accessories Center Cable Tap Box (Dn) F4GC40CBIST
Accessories End Box F4GC20EBIST Accessories End Box F4GC40EBIST
Accessories Flanged End w/ Lugs F4GC20FLIST Accessories Flanged End w/ Lugs F4GC40FLIST
Accessories Flanged End F4GC20FEIST Accessories Flanged End F4GC40FEIST
2500 Amps Three-Phase, Four-Wire Internal Ground Bar Hangers - Common to All Services
Component Type Product Number Component Type Product Number
Linear Lengths 10-ft. plug-in P4GC25SLI10 800 Amps Flatwise (st.) SBF16
Linear Lengths 10-ft. feeder F4GC25SLI10 1000 Amps Flatwise (st.) SBF22
Linear Lengths 10-ft. riser R4GC25SLI10 1200 Amps Flatwise (st.) SBF28
Fitting Elbows; Left F4GC25ELIST 1600Amps Flatwise (st.) SBF42
Fitting Elbows; Right F4GC25ERIST 2500 Amps Flatwise (st.) SBTF
Fitting Elbows; Up F4GC25EUIST 3000 Amps Flatwise (st.) SBTH
Fitting Elbows; Down F4GC25EDIST 4000 Amps Flatwise (st.) SBTH
Accessories End Cable Tap Box (Up) F4GC25TTIST 225-1600 Amps Edgewise (st.) SBE45
Accessories End Cable Tap Box (Dn) F4GC25TBIST 2000-5000 Amps Edgewise (st.) SBTE
Accessories Center Cable Tap Box (Up) F4GC25CTIST 1200 Amps Spring SBR1
Accessories Center Cable Tap Box (Dn) F4GC25CBIST 4000 Amps Spring SBR2
Accessories End Box F4GC25EBIST
Accessories Flanged End w/ Lugs F4GC25FLIST
Accessories Flanged End F4GC25FEIST
True Digital rms Sensing: more accurate and reliable trip 70 65 25 18 SB37SFHG
90 65 25 18 SB39SFHG
interruption. 100 65 25 18 SB310SFHG
110 65 25 18 SB311SFHG
High Interrupting Rating: satisfies high IC requirements up to 125 65 25 18 SB312SFHG
100 kAIC @ 480V. 150 65 25 18 SB315SFHG
175 65 25 18 SB317SFHG
UL listed and CSA Certified for heat rise, short-circuit, and 200 65 25 18 SB320SFHG
ground fault. 225 65 25 18 SB322SFHG
250 65 25 18 SB325SFHG
Interlocks and Safety Features: door interlock, plug interlock,
ground contact before stab contact, and plug assist1 for
mechanical installation. Low-Tier Frames Three-Phase, Three-Wire SGH4GA (400A)
Short Circuit Short Circuit Short Circuit
Trip Rating Rating Rating Product
Amps @ 240V (kAIC) @ 480V (kAIC) @ 600 V (kAIC) Number
Low-Tier Frames Three-Phase, Three-Wire SEDGA
125 65 35 25 SB312SGH4G
Short Circuit Short Circuit Short Circuit 150 65 35 25 SB315SGH4G
Trip Rating Rating Rating Product 175 65 35 25 SB317SGH4G
Amps @ 240V (kAIC) @ 480V (kAIC) @ 600 V (kAIC) Number
200 65 35 25 SB320SGH4G
15 18 14 14 SB31SEDG 225 65 35 25 SB322SGH4G
20 18 14 14 SB32SEDG 250 65 35 25 SB325SGH4G
30 18 14 14 SB33SEDG 300 65 35 25 SB330SGH4G
40 18 14 14 SB34SEDG 350 65 35 25 SB335SGH4G
50 18 14 14 SB35SEDG 400 65 35 25 SB340SGH4G
60 18 14 14 SB36SEDG
70 18 14 14 SB37SEDG
80 18 14 14 SB38SEDG
90 18 14 14 SB39SEDG Low-Tier Frames Three-Phase, Three-Wire SGH6GA (600A)
100 18 14 14 SB310SEDG Short Circuit Short Circuit Short Circuit
110 18 14 14 SB311SEDG Trip Rating Rating Rating Product
125 18 14 14 SB312SEDG Amps @ 240V (kAIC) @ 480V (kAIC) @ 600 V (kAIC) Number
150 18 14 14 SB315SEDG 250 65 35 25 SB325SGH6G
300 65 35 25 SB330SGH6G
350 65 35 25 SB335SGH6G
400 65 35 25 SB340SGH6G
Low-Tier Frames Three-Phase, Three-Wire SEHGA
450 65 35 25 SB345SGH6G
Short Circuit Short Circuit Short Circuit 500 65 35 25 SB350SGH6G
Trip Rating Rating Rating Product 600 65 35 25 SB360SGH6G
Amps @ 240V (kAIC) @ 480V (kAIC) @ 600 V (kAIC) Number
15 65 25 18 SB31SEHG
20 65 25 18 SB32SEHG
30 65 25 18 SB33SEHG Low-Tier Frames Three-Phase, Three-Wire SKHGA
40 65 25 18 SB34SEHG Short Circuit Short Circuit Short Circuit
50 65 25 18 SB35SEHG Trip Rating Rating Rating Product
60 65 25 18 SB36SEHG Amps @ 240V (kAIC) @ 480V (kAIC) @ 600 V (kAIC) Number
70 65 25 18 SB37SEHG 300 65 50 25 SB330SKHG
80 65 25 18 SB38SEHG 400 65 50 25 SB340SKHG
90 65 25 18 SB39SEHG 500 65 50 25 SB350SKHG
100 65 25 18 SB310SEHG 600 65 50 25 SB360SKHG
110 65 25 18 SB311SEHG 700 65 50 25 SB370SKHG
125 65 25 18 SB312SEHG 800 65 50 25 SB380SKHG
150 65 25 18 SB315SEHG
1Optional for E Frame plugs.
Notes: Breakers must be factory-installed. IC rating in rms symmetrical kA.
Low-Tier Frames Three-Phase, Four-Wire SEDGA Low-Tier Frames Three-Phase, Four-Wire SGH6GA (600A)
Short Circuit Short Circuit Short Circuit Short Circuit Short Circuit Short Circuit
Trip Rating Rating Rating Product Trip Rating Rating Rating Product
Amps @ 240V (kAIC) @ 480V (kAIC) @ 600 V (kAIC) Number Amps @ 240V (kAIC) @ 480V (kAIC) @ 600 V (kAIC) Number
15 18 14 14 SB41SEDG 250 65 35 25 SB425SGH6G
20 18 14 14 SB42SEDG 300 65 35 25 SB430SGH6G
30 18 14 14 SB43SEDG 350 65 35 25 SB435SGH6G
40 18 14 14 SB44SEDG 400 65 35 25 SB440SGH6G
50 18 14 14 SB45SEDG 450 65 35 25 SB445SGH6G
60 18 14 14 SB46SEDG 500 65 35 25 SB450SGH6G
70 18 14 14 SB47SEDG 600 65 35 25 SB460SGH6G
80 18 14 14 SB48SEDG
90 18 14 14 SB49SEDG
100 18 14 14 SB410SEDG
110 18 14 14 SB411SEDG Low-Tier Frames Three-Phase, Four-Wire SKHGA
125 18 14 14 SB412SEDG Short Circuit Short Circuit Short Circuit
150 18 14 14 SB415SEDG Trip Rating Rating Rating Product
Amps @ 240V (kAIC) @ 480V (kAIC) @ 600 V (kAIC) Number
300 65 50 25 SB430SKHG
Low-Tier Frames Three-Phase, Four-Wire SEHGA 400 65 50 25 SB440SKHG
500 65 50 25 SB450SKHG
Short Circuit Short Circuit Short Circuit 600 65 50 25 SB460SKHG
Trip Rating Rating Rating Product 700 65 50 25 SB470SKHG
Amps @ 240V (kAIC) @ 480V (kAIC) @ 600 V (kAIC) Number
800 65 50 25 SB480SKHG
15 65 25 18 SB41SEHG
20 65 25 18 SB42SEHG
30 65 25 18 SB43SEHG
40 65 25 18 SB44SEHG Mid-Tier Frames Three-Phase, Three-Wire SELGA
50 65 25 18 SB45SEHG Short Circuit Short Circuit Short Circuit
60 65 25 18 SB46SEHG Trip Rating Rating Rating Product
70 65 25 18 SB47SEHG Amps @ 240V (kAIC) @ 480V (kAIC) @ 600 V (kAIC) Number
80 65 25 18 SB48SEHG
15 100 65 25 SB31SELG
90 65 25 18 SB49SEHG
20 100 65 25 SB32SELG
100 65 25 18 SB410SEHG
30 100 65 25 SB33SELG
110 65 25 18 SB411SEHG
40 100 65 25 SB34SELG
125 65 25 18 SB412SEHG
50 100 65 25 SB35SELG
150 65 25 18 SB415SEHG
60 100 65 25 SB36SELG
70 100 65 25 SB37SELG
80 100 65 25 SB38SELG
Low-Tier Frames Three-Phase, Four-Wire SFHGA 90 100 65 25 SB39SELG
100 100 65 25 SB310SELG
Short Circuit Short Circuit Short Circuit 110 100 65 25 SB311SELG
Trip Rating Rating Rating Product 125 100 65 25 SB312SELG
Amps @ 240V (kAIC) @ 480V (kAIC) @ 600 V (kAIC) Number
150 100 65 25 SB315SELG
70 65 25 18 SB47SFHG
90 65 25 18 SB49SFHG
100 65 25 18 SB410SFHG
110 65 25 18 SB411SFHG Mid-Tier Frames Three-Phase, Three-Wire SFLGA
125 65 25 18 SB412SFHG Short Circuit Short Circuit Short Circuit
150 65 25 18 SB415SFHG Trip Rating Rating Rating Product
175 65 25 18 SB417SFHG Amps @ 240V (kAIC) @ 480V (kAIC) @ 600 V (kAIC) Number
200 65 25 18 SB420SFHG
70 100 65 25 SB37SFLG
225 65 25 18 SB422SFHG
90 100 65 25 SB39SFLG
250 65 25 18 SB425SFHG
100 100 65 25 SB310SFLG
110 100 65 25 SB311SFLG
125 100 65 25 SB312SFLG
Low-Tier Frames Three-Phase, Four-Wire SGH4GA (400A) 150 100 65 25 SB315SFLG
175 100 65 25 SB317SFLG
Short Circuit Short Circuit Short Circuit 200 100 65 25 SB320SFLG
Trip Rating Rating Rating Product 225 100 65 25 SB322SFLG
Amps @ 240V (kAIC) @ 480V (kAIC) @ 600 V (kAIC) Number
250 100 65 25 SB325SFLG
125 65 35 25 SB412SGH4G
150 65 35 25 SB415SGH4G
175 65 35 25 SB417SGH4G
200 65 35 25 SB420SGH4G
225 65 35 25 SB422SGH4G
250 65 35 25 SB425SGH4G
300 65 35 25 SB430SGH4G
350 65 35 25 SB435SGH4G
400 65 35 25 SB440SGH4G
Mid-Tier Frames Three-Phase, Three-Wire SGL4GA Mid-Tier Frames Three-Phase, Four-Wire SFLGA
Short Circuit Short Circuit Short Circuit Short Circuit Short Circuit Short Circuit
Trip Rating Rating Rating Product Trip Rating Rating Rating Product
Amps @ 240V (kAIC) @ 480V (kAIC) @ 600 V (kAIC) Number Amps @ 240V (kAIC) @ 480V (kAIC) @ 600 V (kAIC) Number
125 100 65 65 SB312SGL4G 70 100 65 25 SB47SFLG
150 100 65 65 SB315SGL4G 90 100 65 25 SB49SFLG
175 100 65 65 SB317SGL4G 100 100 65 25 SB410SFLG
200 100 65 65 SB320SGL4G 110 100 65 25 SB411SFLG
225 100 65 65 SB322SGL4G 125 100 65 25 SB412SFLG
250 100 65 65 SB325SGL4G 150 100 65 25 SB415SFLG
300 100 65 65 SB330SGL4G 175 100 65 25 SB417SFLG
350 100 65 65 SB335SGL4G 200 100 65 25 SB420SFLG
400 100 65 65 SB340SGL4G 225 100 65 25 SB422SFLG
250 100 65 25 SB425SFLG
Peak-Tier Frames Three-Phase, Three-Wire SEPGA Peak-Tier Frames Three-Phase, Three-Wire SKPGA
Short Circuit Short Circuit Short Circuit Short Circuit Short Circuit Short Circuit
Trip Rating Rating Rating Product Trip Rating Rating Rating Product
Amps @ 240V (kAIC) @ 480V (kAIC) @ 600 V (kAIC) Number Amps @ 240V (kAIC) @ 480V (kAIC) @ 600 V (kAIC) Number
15 200 100 25 SB31SEPG 300 200 100 25 SB330SKPG
20 200 100 25 SB32SEPG 400 200 100 25 SB340SKPG
30 200 100 25 SB33SEPG 500 200 100 25 SB350SKPG
40 200 100 25 SB34SEPG 600 200 100 25 SB360SKPG
50 200 100 25 SB35SEPG 700 200 100 25 SB370SKPG
60 200 100 25 SB36SEPG 800 200 100 25 SB380SKPG
70 200 100 25 SB37SEPG
80 200 100 25 SB38SEPG
90 200 100 25 SB39SEPG
100 200 100 25 SB310SEPG Peak-Tier Frames Three-Phase, Four-Wire SEPGA
110 200 100 25 SB311SEPG Short Circuit Short Circuit Short Circuit
125 200 100 25 SB312SEPG Trip Rating Rating Rating Product
150 200 100 25 SB315SEPG Amps @ 240V (kAIC) @ 480V (kAIC) @ 600 V (kAIC) Number
15 200 100 25 SB41SEPG
20 200 100 25 SB42SEPG
Peak-Tier Frames Three-Phase, Three-Wire SFPGA 30 200 100 25 SB43SEPG
40 200 100 25 SB44SEPG
Short Circuit Short Circuit Short Circuit 50 200 100 25 SB45SEPG
Trip Rating Rating Rating Product 60 200 100 25 SB46SEPG
Amps @ 240V (kAIC) @ 480V (kAIC) @ 600 V (kAIC) Number
70 200 100 25 SB47SEPG
70 200 100 25 SB37SFPG 80 200 100 25 SB48SEPG
90 200 100 25 SB39SFPG 90 200 100 25 SB49SEPG
100 200 100 25 SB310SFPG 100 200 100 25 SB410SEPG
110 200 100 25 SB311SFPG 110 200 100 25 SB411SEPG
125 200 100 25 SB312SFPG 125 200 100 25 SB412SEPG
150 200 100 25 SB315SFPG 150 200 100 25 SB415SEPG
175 200 100 25 SB317SFPG
200 200 100 25 SB320SFPG
225 200 100 25 SB322SFPG
250 200 100 25 SB325SFPG Peak-Tier Frames Three-Phase, Four-Wire SFPGA
Short Circuit Short Circuit Short Circuit
Trip Rating Rating Rating Product
Amps @ 240V (kAIC) @ 480V (kAIC) @ 600 V (kAIC) Number
Peak-Tier Frames Three-Phase, Three-Wire SGP4GA
70 200 100 25 SB47SFPG
Short Circuit Short Circuit Short Circuit 90 200 100 25 SB49SFPG
Trip Rating Rating Rating Product 100 200 100 25 SB410SFPG
Amps @ 240V (kAIC) @ 480V (kAIC) @ 600 V (kAIC) Number
110 200 100 25 SB411SFPG
125 200 100 65 SB312SGP4G 125 200 100 25 SB412SFPG
150 200 100 65 SB315SGP4G 150 200 100 25 SB415SFPG
175 200 100 65 SB317SGP4G 175 200 100 25 SB417SFPG
200 200 100 65 SB320SGP4G 200 200 100 25 SB420SFPG
225 200 100 65 SB322SGP4G 225 200 100 25 SB422SFPG
250 200 100 65 SB325SGP4G 250 200 100 25 SB425SFPG
300 200 100 65 SB330SGP4G
350 200 100 65 SB335SGP4G
400 200 100 65 SB340SGP4G
Peak-Tier Frames Three-Phase, Four-Wire SGP4GA
Short Circuit Short Circuit Short Circuit
Trip Rating Rating Rating Product
Peak-Tier Frames Three-Phase, Three-Wire SGP6GA Amps @ 240V (kAIC) @ 480V (kAIC) @ 600 V (kAIC) Number
Short Circuit Short Circuit Short Circuit 125 200 100 65 SB412SGP4G
Trip Rating Rating Rating Product 150 200 100 65 SB415SGP4G
Amps @ 240V (kAIC) @ 480V (kAIC) @ 600 V (kAIC) Number
175 200 100 65 SB417SGP4G
250 200 100 65 SB325SGP6G 200 200 100 65 SB420SGP4G
350 200 100 65 SB335SGP6G 225 200 100 65 SB422SGP4G
400 200 100 65 SB340SGP6G 250 200 100 65 SB425SGP4G
450 200 100 65 SB345SGP6G 300 200 100 65 SB430SGP4G
500 200 100 65 SB350SGP6G 350 200 100 65 SB435SGP4G
600 200 100 65 SB360SGP6G 400 200 100 65 SB440SGP4G
Peak-Tier Frames Three-Phase, Four-Wire SGP6GA Without Rating Plug Three-Phase, Four-Wire
Short Circuit Short Circuit Short Circuit Frame Type Trip Amps Product Number
Trip Rating Rating Rating Product
Amps @ 240V (kAIC) @ 480V (kAIC) @ 600 V (kAIC) Number SEDGA 15-30 SB401SEDG
SEDGA 40-60 SB402SEDG
250 200 100 65 SB425SGP6G SEDGA 70-100 SB403SEDG
350 200 100 65 SB435SGP6G SEDGA 110-150 SB404SEDG
400 200 100 65 SB440SGP6G SEHGA 15-30 SB401SEHG
450 200 100 65 SB445SGP6G SEHGA 40-60 SB402SEHG
500 200 100 65 SB450SGP6G SEHGA 70-100 SB403SEHG
600 200 100 65 SB460SGP6G SEHGA 110-150 SB404SEHG
SELGA 15-30 SB401SELG
SELGA 40-60 SB402SELG
SELGA 70-100 SB403SELG
Peak-Tier Frames Three-Phase, Four-Wire SKPGA SELGA 110-150 SB404SELG
Short Circuit Short Circuit Short Circuit SEPGA 15-30 SB401SEPG
Trip Rating Rating Rating Product SEPGA 40-60 SB402SEPG
Amps @ 240V (kAIC) @ 480V (kAIC) @ 600 V (kAIC) Number SEPGA 70-100 SB403SEPG
300 200 100 25 SB430SKPG SEPGA 110-150 SB404SEPG
400 200 100 25 SB440SKPG SFHGA 70-250 SB400SFHG
500 200 100 25 SB450SKPG SFLGA 70-250 SB400SFLG
600 200 100 25 SB460SKPG SFPGA 70-250 SB400SFPG
700 200 100 25 SB470SKPG SGH4GA 125-400 SB400SGH4G
800 200 100 25 SB480SKPG SGL4A 125-400 SB400SGL4G
SGP4GA 125-400 SB400SGP4G
SGH6GA 250-600 SB400SGH6G
SGL6GA 250-600 SB400SGL6G
Without Rating Plug Three-Phase, Three-Wire SGP6GA 250-600 SB400SGP6G
Frame Type Trip Amps Product Number SKHGA 300-800 SB400SKHG
SKLGA 300-800 SB400SKLG
SEDGA 15-30 SB301SEDG SKPGA 300-800 SB400SKPG
SEDGA 40-60 SB302SEDG
SEDGA 70-100 SB303SEDG Notes: Breakers must be factory-installed. IC rating in rms symmetrical kA.
SEDGA 110-150 SB304SEDG Order rating plug separately from BuyLog. Breakers must be factory-installed. Plug
SEHGA 15-30 SB301SEHG assist optional for E frame plugs.
SEHGA 40-60 SB302SEHG
SEHGA 70-100 SB303SEHG
SEHGA 110-150 SB304SEHG
SELGA 15-30 SB301SELG
SELGA 40-60 SB302SELG
SELGA 70-100 SB303SELG
SELGA 110-150 SB304SELG
SEPGA 15-30 SB301SEPG
SEPGA 40-60 SB302SEPG
SEPGA 70-100 SB303SEPG
SEPGA 110-150 SB304SEPG
SFHGA 70-250 SB300SFHG
SFLGA 70-250 SB300SFLG
SFPGA 70-250 SB300SFPG
SGH4GA 125-400 SB300SGH4G
SGL4A 125-400 SB300SGL4G
SGP4GA 125-400 SB300SGP4G
SGH6GA 250-600 SB300SGH6G
SGL6GA 250-600 SB300SGL6G
SGP6GA 250-600 SB300SGP6G
SKHGA 300-800 SB300SKHG
SKLGA 300-800 SB300SKLG
SKPGA 300-800 SB300SKPG
Features and Benefits Low Tier Frames (Ground Fault) Three-Phase, Three-Wire
MicroVersaTrip Plus Trip Units Standard Frame Type Trip Amps Product Number
Low Tier Frames Three-Phase, Three-Wire Mid Tier Frames (Ground Fault) Three-Phase, Three-Wire
Frame Type Trip Amps Product Number Frame Type Trip Amps Product Number
SGHB 60 SB36SGHG+ SGLB 60 SB36SGLGF+
SGHB 80 SB38SGHG+ SGLB 80 SB38SGLGF+
SGHB 100 SB310SGHG+ SGLB 100 SB310SGLGF+
SGHB 125 SB312SGHG+ SGLB 125 SB312SGLGF+
SGHB 150 SB315SGHG+ SGLB 150 SB315SGLGF+
SGH4B 150 SB315SGH4G+ SGL4B 150 SB315SGL4GF+
SGH4B 200 SB320SGH4G+ SGL4B 200 SB320SGL4GF+
SGH4B 225 SB322SGH4G+ SGL4B 225 SB322SGL4GF+
SGH4B 250 SB325SGH4G+ SGL4B 250 SB325SGL4GF+
SGH4B 300 SB330SGH4G+ SGL4B 300 SB330SGL4GF+
SGH4B 350 SB335SGH4G+ SGL4B 350 SB335SGL4GF+
SGH4B 400 SB340SGH4G+ SGL4B 400 SB340SGL4GF+
SGH6B 300 SB330SGH6G+ SGL6B 300 SB330SGL6GF+
SGH6B 400 SB340SGH6G+ SGL6B 400 SB340SGL6GF+
SGH6B 450 SB345SGH6G+ SGL6B 450 SB345SGL6GF+
SGH6B 500 SB350SGH6G+ SGL6B 500 SB350SGL6GF+
SGH6B 600 SB360SGH6G+ SGL6B 600 SB360SGL6GF+
SKHB 300 SB330SKHG+ SKLB 300 SB330SKLGF+
SKHB 400 SB340SKHG+ SKLB 400 SB340SKLGF+
SKHB 500 SB350SKHG+ SKLB 500 SB350SKLGF+
SKHB 600 SB360SKHG+ SKLB 600 SB360SKLGF+
SKHB 700 SB370SKHG+ SKLB 700 SB370SKLGF+
SKHB 800 SB380SKHG+ SKLB 800 SB380SKLGF+
Low Tier Frames Three-Phase, Four-Wire Mid Tier Frames (Ground Fault) Three-Phase, Four-Wire
Frame Type Trip Amps Product Number Frame Type Trip Amps Product Number
SGHB 60 SB46SGHG+ SGLB 60 SB46SGLGF+
SGHB 80 SB48SGHG+ SGLB 80 SB48SGLGF+
SGHB 100 SB410SGHG+ SGLB 100 SB410SGLGF+
SGHB 125 SB412SGHG+ SGLB 125 SB412SGLGF+
SGHB 150 SB415SGHG+ SGLB 150 SB415SGLGF+
SGH4B 150 SB415SGH4G+ SGL4B 150 SB415SGL4GF+
SGH4B 200 SB420SGH4G+ SGL4B 200 SB420SGL4GF+
SGH4B 225 SB422SGH4G+ SGL4B 225 SB422SGL4GF+
SGH4B 250 SB425SGH4G+ SGL4B 250 SB425SGL4GF+
SGH4B 300 SB430SGH4G+ SGL4B 300 SB430SGL4GF+
SGH4B 350 SB435SGH4G+ SGL4B 350 SB435SGL4GF+
SGH4B 400 SB440SGH4G+ SGL4B 400 SB440SGL4GF+
SGH6B 300 SB430SGH6G+ SGL6B 300 SB430SGL6GF+
SGH6B 400 SB440SGH6G+ SGL6B 400 SB440SGL6GF+
SGH6B 450 SB445SGH6G+ SGL6B 450 SB445SGL6GF+
SGH6B 500 SB450SGH6G+ SGL6B 500 SB450SGL6GF+
SGH6B 600 SB460SGH6G+ SGL6B 600 SB460SGL6GF+
SKHB 300 SB430SKHG+ SKLB 300 SB430SKLGF+
SKHB 400 SB440SKHG+ SKLB 400 SB440SKLGF+
SKHB 500 SB450SKHG+ SKLB 500 SB450SKLGF+
SKHB 600 SB460SKHG+ SKLB 600 SB460SKLGF+
SKHB 700 SB470SKHG+ SKLB 700 SB470SKLGF+
SKHB 800 SB480SKHG+ SKLB 800 SB480SKLGF+
LIT trip function is standard. LSIT is additional. LIGT trip function is standard. LSIGT is additional.
Mid Tier Frames Three-Phase, Three-Wire Peak Tier Frames (Ground Fault) Three-Phase, Three-Wire
Frame Type Trip Amps Product Number Frame Type Trip Amps Product Number
SGLB 60 SB36SGLG+ SGPB 60 SB36SGPGF+
SGLB 80 SB38SGLG+ SGPB 80 SB38SGPGF+
SGLB 100 SB310SGLG+ SGPB 100 SB310SGPGF+
SGLB 125 SB312SGLG+ SGPB 125 SB312SGPGF+
SGLB 150 SB315SGLG+ SGPB 150 SB315SGPGF+
SGL4B 150 SB315SGL4G+ SGP4B 150 SB315SGP4GF+
SGL4B 200 SB320SGL4G+ SGP4B 200 SB320SGP4GF+
SGL4B 225 SB322SGL4G+ SGP4B 225 SB322SGP4GF+
SGL4B 250 SB325SGL4G+ SGP4B 250 SB325SGP4GF+
SGL4B 300 SB330SGL4G+ SGP4B 300 SB330SGP4GF+
SGL4B 350 SB335SGL4G+ SGP4B 350 SB335SGP4GF+
SGL4B 400 SB340SGL4G+ SGP4B 400 SB340SGP4GF+
SGL6B 300 SB330SGL6G+ SGP6B 300 SB330SGP6GF+
SGL6B 400 SB340SGL6G+ SGP6B 400 SB340SGP6GF+
SGL6B 450 SB345SGL6G+ SGP6B 450 SB345SGP6GF+
SGL6B 500 SB350SGL6G+ SGP6B 500 SB350SGP6GF+
SGL6B 600 SB360SGL6G+ SGP6B 600 SB360SGP6GF+
SKLB 300 SB330SKLG+ SKPB 300 SB330SKPGF+
SKLB 400 SB340SKLG+ SKPB 400 SB340SKPGF+
SKLB 500 SB350SKLG+ SKPB 500 SB350SKPGF+
SKLB 600 SB360SKLG+ SKPB 600 SB360SKPGF+
SKLB 700 SB370SKLG+ SKPB 700 SB370SKPGF+
SKLB 800 SB380SKLG+ SKPB 800 SB380SKPGF+
Mid Tier Frames Three-Phase, Four-Wire Peak Tier Frames (Ground Fault) Three-Phase, Four-Wire
Frame Type Trip Amps Product Number Frame Type Trip Amps Product Number
SGLB 60 SB46SGLG+ SGPB 60 SB46SGPGF+
SGLB 80 SB48SGLG+ SGPB 80 SB48SGPGF+
SGLB 100 SB410SGLG+ SGPB 100 SB410SGPGF+
SGLB 125 SB412SGLG+ SGPB 125 SB412SGPGF+
SGLB 150 SB415SGLG+ SGPB 150 SB415SGPGF+
SGL4B 150 SB415SGL4G+ SGP4B 150 SB415SGP4GF+
SGL4B 200 SB420SGL4G+ SGP4B 200 SB420SGP4GF+
SGL4B 225 SB422SGL4G+ SGP4B 225 SB422SGP4GF+
SGL4B 250 SB425SGL4G+ SGP4B 250 SB425SGP4GF+
SGL4B 300 SB430SGL4G+ SGP4B 300 SB430SGP4GF+
SGL4B 350 SB435SGL4G+ SGP4B 350 SB435SGP4GF+
SGL4B 400 SB440SGL4G+ SGP4B 400 SB440SGP4GF+
SGL6B 300 SB430SGL6G+ SGP6B 300 SB430SGP6GF+
SGL6B 400 SB440SGL6G+ SGP6B 400 SB440SGP6GF+
SGL6B 450 SB445SGL6G+ SGP6B 450 SB445SGP6GF+
SGL6B 500 SB450SGL6G+ SGP6B 500 SB450SGP6GF+
SGL6B 600 SB460SGL6G+ SGP6B 600 SB460SGP6GF+
SKLB 300 SB430SKLG+ SKPB 300 SB430SKPGF+
SKLB 400 SB440SKLG+ SKPB 400 SB440SKPGF+
SKLB 500 SB450SKLG+ SKPB 500 SB450SKPGF+
SKLB 600 SB460SKLG+ SKPB 600 SB460SKPGF+
SKLB 700 SB470SKLG+ SKPB 700 SB470SKPGF+
SKLB 800 SB480SKLG+ SKPB 800 SB480SKPGF+
LIT trip function is standard. LSIT is additional. LIGT trip function is standard. LSIGT is additional.
Ground Contact: before stab contact. 600 Volts Inter. Trip 70 SB37FKG
600 Volts Inter. Trip 100 SB310FKG
Interlock: to insure that plug is off when engaging bus and 600 Volts Inter. Trip 125 SB312FKG
when removing plug. 600 Volts Inter. Trip 150 SB315FKG
Door Interlock: plug must be off to open door. 600 Volts Inter. Trip 200 SB320FKG
600 Volts Inter. Trip 225 SB322FKG
Standard Frames Three-Phase, Three-Wire TEB Standard Frames Three-Phase, Three-Wire TJJ
Voltage Trip Amps Product Number Voltage Trip Amps Product Number
240 Volts Fixed Trip 15 SB31EBG 600 Volts Fixed Trip 125 SB312JJG
240 Volts Fixed Trip 20 SB32EBG 600 Volts Fixed Trip 150 SB315JJG
240 Volts Fixed Trip 30 SB33EBG 600 Volts Fixed Trip 200 SB320JJG
240 Volts Fixed Trip 40 SB34EBG 600 Volts Fixed Trip 225 SB322JJG
240 Volts Fixed Trip 50 SB35EBG 600 Volts Fixed Trip 300 SB330JJG
240 Volts Fixed Trip 60 SB36EBG 600 Volts Fixed Trip 400 SB340JJG
240 Volts Fixed Trip 70 SB37EBG
240 Volts Fixed Trip 100 SB310EBG
Voltage Trip Amps Product Number 600 Volts Inter. Trip 125 SB312JK4G
600 Volts Inter. Trip 150 SB315JK4G
480 Volts Fixed Trip 15 SB31ED4G 600 Volts Inter. Trip 175 SB317JK4G
480 Volts Fixed Trip 20 SB32ED4G 600 Volts Inter. Trip 200 SB320JK4G
480 Volts Fixed Trip 30 SB33ED4G 600 Volts Inter. Trip 225 SB322JK4G
480 Volts Fixed Trip 40 SB34ED4G 600 Volts Inter. Trip 300 SB330JK4G
480 Volts Fixed Trip 50 SB35ED4G 600 Volts Inter. Trip 400 SB340JK4G
480 Volts Fixed Trip 60 SB36ED4G
480 Volts Fixed Trip 70 SB37ED4G
480 Volts Fixed Trip 100 SB310ED4G
Standard Frames Three-Phase, Three-Wire TJK6
Voltage Trip Amps Product Number
Standard Frames Three-Phase, Three-Wire TED6 600 Volts Inter. Trip 400 SB340JK6G
Voltage Trip Amps Product Number 600 Volts Inter. Trip 450 SB345JK6G
600 Volts Inter. Trip 500 SB350JK6G
600 Volts Fixed Trip 15 SB31ED6G 600 Volts Inter. Trip 600 SB360JK6G
600 Volts Fixed Trip 20 SB32ED6G
600 Volts Fixed Trip 30 SB33ED6G
600 Volts Fixed Trip 40 SB34ED6G
600 Volts Fixed Trip 50 SB35ED6G Standard Frames Three-Phase, Three-Wire TKM8
600 Volts Fixed Trip 60 SB36ED6G
Voltage Trip Amps Product Number
600 Volts Fixed Trip 70 SB37ED6G
600 Volts Fixed Trip 100 SB310ED6G 600 Volts Inter. Trip 300 SB330KMG
600 Volts Inter. Trip 400 SB340KMG
600 Volts Inter. Trip 500 SB350KMG
600 Volts Inter. Trip 600 SB360KMG
Standard Frames Three-Phase, Three-Wire TFJ 600 Volts Inter. Trip 700 SB370KMG
Voltage Trip Amps Product Number 600 Volts Inter. Trip 800 SB380KMG
Standard Frames Three-Phase, Four-Wire TED4 Standard Frames Three-Phase, Four-Wire TJK4
Voltage Trip Amps Product Number Voltage Trip Amps Product Number
480 Volts Fixed Trip 15 SB41ED4G 600 Volts Inter. Trip 125 SB412JK4G
480 Volts Fixed Trip 20 SB42ED4G 600 Volts Inter. Trip 150 SB415JK4G
480 Volts Fixed Trip 30 SB43ED4G 600 Volts Inter. Trip 175 SB417JK4G
480 Volts Fixed Trip 40 SB44ED4G 600 Volts Inter. Trip 200 SB420JK4G
480 Volts Fixed Trip 50 SB45ED4G 600 Volts Inter. Trip 225 SB422JK4G
480 Volts Fixed Trip 60 SB46ED4G 600 Volts Inter. Trip 300 SB430JK4G
480 Volts Fixed Trip 70 SB47ED4G 600 Volts Inter. Trip 400 SB440JK4G
480 Volts Fixed Trip 100 SB410ED4G
Hi-Break Frames Three-Phase, Three-Wire THJK6 Hi-Break Frames Three-Phase, Four-Wire THKM8
Voltage Trip Amps Product Number Voltage Trip Amps Product Number
600 Volts Inter. Trip 400 SB340HJK6G 600 Volts Inter. Trip 300 SB430HKMG
600 Volts Inter. Trip 450 SB345HJK6G 600 Volts Inter. Trip 400 SB440HKMG
600 Volts Inter. Trip 500 SB350HJK6G 600 Volts Inter. Trip 500 SB450HKMG
600 Volts Inter. Trip 600 SB360HJK6G 600 Volts Inter. Trip 600 SB460HKMG
600 Volts Inter. Trip 700 SB470HKMG
600 Volts Inter. Trip 800 SB480HKMG
Adapter Kits Convert Spectra Series plugs to Armor-Clad Miscellaneous Plug Modifications
Amperage Product Number Plug AssistStandard for plugs over 100 amperes. Add suffix
30-100 SBAC1G P to the product number for plugs 100 amperes and below.
150-250 SBAC4G
400-800 SBAC5G Drip-Proof PlugsIncludes cover and stab gasketing. Add suffix
Ground stabs included. I to product number.
Splashproof (IP54) PlugsAdd suffix Z to the product number.
Adapter Kits Spectra MVT + OptionAdd suffix + to the product number.
Convert Spectra Series Bus Plugs to Spectra LowAmp Bus Include note describing type of trip unit.
Amperage Product Number
30-100 SBSL1G
200-225 SBSL4G
400-600 SBSL5G
Contactor Plugs
Contactor Plugs are available in 30, 60 and 100 amps and have
the following options:
Electronically Held
Mechanically Held
Pilot Lights
Pushbutton
Selector Switches
Control Transformers
Extra Interlocks
Two-Wire Controls
Auxiliary Contacts
Contact the factory for pricing details.
NA = Not Available
Decimal Fraction
.12 1/8
.38 3/8
.63 5/8
.88 7/8
Nominal Position
Combination Elbow
Flat Elbows1
Standard Dimensions (Inches)
Amp X Y
Al 225-1350 12 12
1600-3000 18 18
4000 24 24
Cu 225-2000 12 12
2500-4000 18 18
5000 24 24
Mechanical-type (CU-AI wires) lugs standard; Crimp-type optional. Important: Local code requirements can affect
Standard Box Down Position, Side View
the dimensions, number of lugs furnished, etc. In these situations, refer to Company.
Transformer Taps
Hangers
Vertical MountingSpring Hangers (Must be ordered separately)
Spring hangers should be ordered to support the busway at each floor if floor-to-floor
span is less than 16 feet. When the floor-to-floor span is over 16 feet, supports and
additional spring hangers are required on 16 foot centers maximum. The quantity of Product Number SBR X
springs supplied is based on total weight of busway and devices installed per floor. Common to All Services
Simple adjustment procedures are included with installation instructions. Mounting holes Note: Floor or wall opening should provide
align with floor flanges. 1/2 clearance all around busway.
Product Number (SBR X) where X = Quantity of springs (1 or 2) on each side of hanger
(single spring up to 600 lbs. per floor).
Refer to Installation Instructions DEH-40087 for A Dimension.
design allow takeoffs to be mounted at any joint, whether feeder 400A JJ 24 15.50 10.75
225-1200 Al 2.875
16.50
225-1600 Cu 3.375
1 4.250
4.500
5.750
1350-2000 Al 6.500 20.00
2000-2500 Cu
8.250
2500 Al 4.250
24.75
3000 Cu 4.500
Fig. 4 Meter-mod Metering (in line device)
2 5.750
Available for G&K Frame Spectra C/B only 3000-4000 Al 6.500 32.00
4000-5000 Cu
8.250
Flex-A-Tap Device (Fig. 1)
Decimal Fraction
Device "H " " W" "D "
.12 1/8
Cable Tap Box 54" 24" 15 1/2"
.38 3/8
KM 66" 19 9/32" 15 1/2"
.63 5/8
QMW 600A 66" 19 9/32" 15 1/2"
.88 7/8
Power Break II 63" 24 9/32" 18"
1TMZR mounting Z-rail must be added for the attached Meter Mod.
L F 3 H C 02 SL 02 B
Type Code
Description Code Indoor Blank
Product
Spectra Series Low/Amp L Transverse Barrier3 B
Feeder F
Type
Plug-In4 P
3PH, 3W 3 Type Feet Code
Service
3PH, 4W 100% Neutral 4 2 02
Integrated Housing H 3 03
Ground Feeder
Internal Bus1 G 5 05
Copper C Amp Code 10 10
Conductor
Aluminum A 225 02 4 04
400 04 Plug-In 6 06
Configurations Code 600 06 10 10
Straight Length SL 800 08 Fittings NA ST
ElbowLeft EL Off Sets:
ElbowRight ER Configurations Code 6" 06
ElbowUp EU Busway Adapter 12" 12
ElbowDown ED Spectra Bus SB 18" 18
Center Cable Tap BoxUp CT Armor-Clad Style 3 Blot End BE
Center Cable Tap BoxDown CB Armor-Clad Style 3 Slot End SE
End Cable Tap BoxUp TT Busway Stubs (600-800)2,3
End Cable Tap BoxDown TB Spectra/AV-Line Switchboard SA
End Box EB AKD8/Power Break AK
Flanged End FE MCC 8000 Line MC
Flanged End w/Lugs FL Panelboards PA
Adjustable StraightLength AS
Expansion LengthUp XU
Expansion LengthDown XD
Total Phase Transposition TF
TeeRight TR
TeeLeft TL
TeeUp TU
TeeDown TD
Off SetUp OU
Off SetDown OD
Off SetRight OR
Off SetLeft OL
1 Available w/copper bus bars only.
2 Requires drawing for layout configuration.
3 Item available in feeder construction only. (Use with fire barrier and wall/floor flange for 3-hour fire rating)
4 Straight lengths only.
225 Amps Three-Phase, Four-Wire Integrated Housing Ground 400 Amps Three-Phase, Four-Wire Integrated Housing Ground
Component Type Product Number Component Type Product Number
Linear Lengths Plug-In: 10-ft. LP4HA02SL10 Linear Lengths Plug-In: 10-ft. LP4HA04SL10
Linear Lengths Plug-In: 6-ft. LP4HA02SL06 Linear Lengths Plug-In: 6-ft. LP4HA04SL06
Linear Lengths Plug-In: 4-ft. LP4HA02SL04 Linear Lengths Plug-In: 4-ft. LP4HA04SL04
Linear Lengths Feeder: 10-ft. LF4HA02SL10 Linear Lengths Feeder: 10-ft. LF4HA04SL10
Linear Lengths Feeder: 5-ft. LF4HA02SL05 Linear Lengths Feeder: 5-ft. LF4HA04SL05
Linear Lengths Feeder: 3-ft. LF4HA02SL03 Linear Lengths Feeder: 3-ft. LF4HA04SL03
Linear Lengths Feeder: 2-ft. LF4HA02SL02 Linear Lengths Feeder: 2-ft. LF4HA04SL02
Linear Lengths Adjustable Straight Length LF4HA02ASST Linear Lengths Adjustable Straight Length LF4HA04ASST
Fittings Elbow Left 90 LF4HA02ELST Fittings Elbow Left 90 LF4HA04ELST
Fittings Elbow Right 90 LF4HA02ERST Fittings Elbow Right 90 LF4HA04ERST
Fittings Elbow Up 90 LF4HA02EUST Fittings Elbow Up 90 LF4HA04EUST
Fittings Elbow Down 90 LF4HA02EDST Fittings Elbow Down 90 LF4HA04EDST
Accessories End Cable Tap BoxUp LF4HA02TTST Accessories End Cable Tap BoxUp LF4HA04TTST
Accessories End Cable Tap BoxDown LF4HA02TBST Accessories End Cable Tap BoxDown LF4HA04TBST
Accessories Center Cable Tap BoxUp LF4HA02CTST Accessories Center Cable Tap BoxUp LF4HA04CTST
Accessories Center Cable Tap BoxDown LF4HA02CBST Accessories Center Cable Tap BoxDown LF4HA04CBST
Accessories End Box LF4HA02EBST Accessories End Box LF4HA04EBST
Accessories Flanged End w/Lugs LF4HA02FLST Accessories Flanged End w/Lugs LF4HA04FLST
Accessories Flanged End LF4HA02FEST Accessories Flanged End LF4HA04FEST
Fittings Expansion LengthUp LF4HA02XUST Fittings Expansion LengthUp LF4HA04XUST
Fittings Expansion LengthDown LF4HA02XDST Fittings Expansion LengthDown LF4HA04XDST
Fittings Total Phase Transposition LF4HA02TFST Fittings Total Phase Transposition LF4HA04TFST
Fittings TeeRight LF4HA02TRST Fittings TeeRight LF4HA04TRST
Fittings TeeLeft LF4HA02TLST Fittings TeeLeft LF4HA04TLST
Fittings TeeUp LF4HA02TUST Fittings TeeUp LF4HA04TUST
Fittings TeeDown LF4HA02TDST Fittings TeeDown LF4HA04TDST
Fittings Off SetUp (6) LF4HA02OU06 Fittings Off SetUp (6) LF4HA04OU06
Fittings Off SetUp (12) LF4HA02OU12 Fittings Off SetUp (12) LF4HA04OU12
Fittings Off SetUp (18) LF4HA02OU18 Fittings Off SetUp (18) LF4HA04OU18
Fittings Off SetDown (6) LF4HA02OD06 Fittings Off SetDown (6) LF4HA04OD06
Fittings Off SetDown (12) LF4HA02OD12 Fittings Off SetDown (12) LF4HA04OD12
Fittings Off SetDown (18) LF4HA02OD18 Fittings Off SetDown (18) LF4HA04OD18
Fittings Off SetLeft (6) LF4HA02OL06 Fittings Off SetLeft (6) LF4HA04OL06
Fittings Off SetLeft (12) LF4HA02OL12 Fittings Off SetLeft (12) LF4HA04OL12
Fittings Off SetLeft (18) LF4HA02OL18 Fittings Off SetLeft (18) LF4HA04OL18
Fittings Off SetRight (6) LF4HA02OR06 Fittings Off SetRight (6) LF4HA04OR06
Fittings Off SetRight (12) LF4HA02OR12 Fittings Off SetRight (12) LF4HA04OR12
Fittings Off Set Right (18) LF4HA02OR18 Fittings Off Set Right (18) LF4HA04OR18
600 Amps Three-Phase, Four-Wire Integrated Housing Ground 800 Amps Three-Phase, Four-Wire Integrated Housing Ground
Component Type Product Number Component Type Product Number
Linear Lengths Plug-In: 10-ft. LP4HA06SL10 Linear Lengths Plug-In: 10-ft. LP4HA08SL10
Linear Lengths Plug-In: 6-ft. LP4HA06SL06 Linear Lengths Plug-In: 6-ft. LP4HA08SL06
Linear Lengths Plug-In: 4-ft. LP4HA06SL04 Linear Lengths Plug-In: 4-ft. LP4HA08SL04
Linear Lengths Feeder: 10-ft. LF4HA06SL10 Linear Lengths Feeder: 10-ft. LF4HA08SL10
Linear Lengths Feeder: 5-ft. LF4HA06SL05 Linear Lengths Feeder: 5-ft. LF4HA08SL05
Linear Lengths Feeder: 3-ft. LF4HA06SL03 Linear Lengths Feeder: 3-ft. LF4HA08SL03
Linear Lengths Feeder: 2-ft. LF4HA06SL02 Linear Lengths Feeder: 2-ft. LF4HA08SL02
Linear Lengths Adjustable Straight Length LF4HA06ASST Linear Lengths Adjustable Straight Length LF4HA08ASST
Fittings Elbow Left 90 LF4HA06ELST Fittings Elbow Left 90 LF4HA08ELST
Fittings Elbow Right 90 LF4HA06ERST Fittings Elbow Right 90 LF4HA08ERST
Fittings Elbow Up 90 LF4HA06EUST Fittings Elbow Up 90 LF4HA08EUST
Fittings Elbow Down 90 LF4HA06EDST Fittings Elbow Down 90 LF4HA08EDST
Accessories End Cable Tap BoxUp LF4HA06TTST Accessories End Cable Tap BoxUp LF4HA08TTST
Accessories End Cable Tap BoxDown LF4HA06TBST Accessories End Cable Tap BoxDown LF4HA08TBST
Accessories Center Cable Tap BoxUp LF4HA06CTST Accessories Center Cable Tap BoxUp LF4HA08CTS
Accessories Center Cable Tap BoxDown LF4HA06CBST Accessories Center Cable Tap BoxDown LF4HA08CBST
Accessories End Box LF4HA06EBST Accessories End Box LF4HA08EBST
Accessories Flanged End w/Lugs LF4HA06FLST Accessories Flanged End w/Lugs LF4HA08FLST
Accessories Flanged End LF4HA06FEST Accessories Flanged End LF4HA08FEST
Fittings Expansion LengthUp LF4HA06XUST Fittings Expansion LengthUp LF4HA08XUST
Fittings Expansion LengthDown LF4HA06XDST Fittings Expansion LengthDown LF4HA08XDST
Fittings Total Phase Transposition LF4HA06TFST Fittings Total Phase Transposition LF4HA08TFST
Fittings TeeRight LF4HA06TRST Fittings TeeRight LF4HA08TRST
Fittings TeeLeft LF4HA06TLST Fittings TeeLeft LF4HA08TLST
Fittings TeeUp LF4HA06TUST Fittings TeeUp LF4HA08TUST
Fittings TeeDown LF4HA06TDST Fittings TeeDown LF4HA08TDST
Fittings Off SetUp (6) LF4HA06OU06 Fittings Off SetUp (6) LF4HA08OU06
Fittings Off SetUp (12) LF4HA06OU12 Fittings Off SetUp (12) LF4HA08OU12
Fittings Off SetUp (18) LF4HA06OU18 Fittings Off SetUp (18) LF4HA08OU18
Fittings Off SetDown (6) LF4HA06OD06 Fittings Off SetDown (6) LF4HA08OD06
Fittings Off SetDown (12) LF4HA06OD12 Fittings Off SetDown (12) LF4HA08OD12
Fittings Off SetDown (18) LF4HA06OD18 Fittings Off SetDown (18) LF4HA08OD18
Fittings Off SetLeft (6) LF4HA06OL06 Fittings Off SetLeft (6) LF4HA08OL06
Fittings Off SetLeft (12) LF4HA06OL12 Fittings Off SetLeft (12) LF4HA08OL12
Fittings Off SetLeft (18) LF4HA06OL18 Fittings Off SetLeft (18) LF4HA08OL18
Fittings Off SetRight (6) LF4HA06OR06 Fittings Off SetRight (6) LF4HA08OR06
Fittings Off SetRight (12) LF4HA06OR12 Fittings Off SetRight (12) LF4HA08OR12
Fittings Off Set Right (18) LF4HA06OR18 Fittings Off Set Right (18) LF4HA08OR18
225 Amps Three-Phase, Three-Wire Integrated Housing Ground 400 Amps Three-Phase, Three-Wire Integrated Housing Ground
Component Type Product Number Component Type Product Number
Linear Lengths Plug-In: 10-ft. LP3HC02SL10 Linear Lengths Plug-In: 10-ft. LP3HC04SL10
Linear Lengths Plug-In: 6-ft. LP3HC02SL06 Linear Lengths Plug-In: 6-ft. LP3HC04SL06
Linear Lengths Plug-In: 4-ft. LP3HC02SL04 Linear Lengths Plug-In: 4-ft. LP3HC04SL04
Linear Lengths Feeder: 10-ft. LF3HC02SL10 Linear Lengths Feeder: 10-ft. LF3HC04SL10
Linear Lengths Feeder: 5-ft. LF3HC02SL05 Linear Lengths Feeder: 5-ft. LF3HC04SL05
Linear Lengths Feeder: 3-ft. LF3HC02SL03 Linear Lengths Feeder: 3-ft. LF3HC04SL03
Linear Lengths Feeder: 2-ft. LF3HC02SL02 Linear Lengths Feeder: 2-ft. LF3HC04SL02
Linear Lengths Adjustable Straight Length LF3HC02ASST Linear Lengths Adjustable Straight Length LF3HC04ASST
Fittings Elbow Left 90 LF3HC02ELST Fittings Elbow Left 90 LF3HC04ELST
Fittings Elbow Right 90 LF3HC02ERST Fittings Elbow Right 90 LF3HC04ERST
Fittings Elbow Up 90 LF3HC02EUST Fittings Elbow Up 90 LF3HC04EUST
Fittings Elbow Down 90 LF3HC02EDST Fittings Elbow Down 90 LF3HC04EDST
Accessories End Cable Tap BoxUp LF3HC02TTST Accessories End Cable Tap BoxUp LF3HC04TTST
Accessories End Cable Tap BoxDown LF3HC02TBST Accessories End Cable Tap BoxDown LF3HC04TBST
Accessories Center Cable Tap BoxUp LF3HC02CTST Accessories Center Cable Tap BoxUp LF3HC04CTST
Accessories Center Cable Tap BoxDown LF3HC02CBST Accessories Center Cable Tap BoxDown LF3HC04CBST
Accessories End Box LF3HC02EBST Accessories End Box LF3HC04EBST
Accessories Flanged End w/Lugs LF3HC02FLST Accessories Flanged End w/Lugs LF3HC04FLST
Accessories Flanged End LF3HC02FEST Accessories Flanged End LF3HC04FEST
Fittings Expansion LengthUp LF3HC02XUST Fittings Expansion LengthUp LF3HC04XUST
Fittings Expansion LengthDown LF3HC02XDST Fittings Expansion LengthDown LF3HC04XDST
Fittings Total Phase Transposition LF3HC02TFST Fittings Total Phase Transposition LF3HC04TFST
Fittings TeeRight LF3HC02TRST Fittings TeeRight LF3HC04TRST
Fittings TeeLeft LF3HC02TLST Fittings TeeLeft LF3HC04TLST
Fittings TeeUp LF3HC02TUST Fittings TeeUp LF3HC04TUST
Fittings TeeDown LF3HC02TDST Fittings TeeDown LF3HC04TDST
Fittings Off SetUp (6) LF3HC02OU06 Fittings Off SetUp (6) LF3HC04OU06
Fittings Off SetUp (12) LF3HC02OU12 Fittings Off SetUp (12) LF3HC04OU12
Fittings Off SetUp (18) LF3HC02OU18 Fittings Off SetUp (18) LF3HC04OU18
Fittings Off SetDown (6) LF3HC02OD06 Fittings Off SetDown (6) LF3HC04OD06
Fittings Off SetDown (12) LF3HC02OD12 Fittings Off SetDown (12) LF3HC04OD12
Fittings Off SetDown (18) LF3HC02OD18 Fittings Off SetDown (18) LF3HC04OD18
Fittings Off SetLeft (6) LF3HC02OL06 Fittings Off SetLeft (6) LF3HC04OL06
Fittings Off SetLeft (12) LF3HC02OL12 Fittings Off SetLeft (12) LF3HC04OL12
Fittings Off SetLeft (18) LF3HC02OL18 Fittings Off SetLeft (18) LF3HC04OL18
Fittings Off SetRight (6) LF3HC02OR06 Fittings Off SetRight (6) LF3HC04OR06
Fittings Off SetRight (12) LF3HC02OR12 Fittings Off SetRight (12) LF3HC04OR12
Fittings Off Set Right (18) LF3HC02OR18 Fittings Off Set Right (18) LF3HC04OR18
600 Amps Three-Phase, Three-Wire Integrated Housing Ground 800 Amps Three-Phase, Three-Wire Integrated Housing Ground
Component Type Product Number Component Type Product Number
Linear Lengths Plug-In: 10-ft. LP3HC06SL10 Linear Lengths Plug-In: 10-ft. LP3HC08SL10
Linear Lengths Plug-In: 6-ft. LP3HC06SL06 Linear Lengths Plug-In: 6-ft. LP3HC08SL06
Linear Lengths Plug-In: 4-ft. LP3HC06SL04 Linear Lengths Plug-In: 4-ft. LP3HC08SL04
Linear Lengths Feeder: 10-ft. LF3HC06SL10 Linear Lengths Feeder: 10-ft. LF3HC08SL10
Linear Lengths Feeder: 5-ft. LF3HC06SL05 Linear Lengths Feeder: 5-ft. LF3HC08SL05
Linear Lengths Feeder: 3-ft. LF3HC06SL03 Linear Lengths Feeder: 3-ft. LF3HC08SL03
Linear Lengths Feeder: 2-ft. LF3HC06SL02 Linear Lengths Feeder: 2-ft. LF3HC08SL02
Linear Lengths Adjustable Straight Length LF3HC06ASST Linear Lengths Adjustable Straight Length LF3HC08ASST
Fittings Elbow Left 90 LF3HC06ELST Fittings Elbow Left 90 LF3HC08ELST
Fittings Elbow Right 90 LF3HC06ERST Fittings Elbow Right 90 LF3HC08ERST
Fittings Elbow Up 90 LF3HC06EUST Fittings Elbow Up 90 LF3HC08EUST
Fittings Elbow Down 90 LF3HC06EDST Fittings Elbow Down 90 LF3HC08EDST
Accessories End Cable Tap BoxUp LF3HC06TTST Accessories End Cable Tap BoxUp LF3HC08TTST
Accessories End Cable Tap BoxDown LF3HC06TBST Accessories End Cable Tap BoxDown LF3HC08TBST
Accessories Center Cable Tap BoxUp LF3HC06CTST Accessories Center Cable Tap BoxUp LF3HC08CTST
Accessories Center Cable Tap BoxDown LF3HC06CBST Accessories Center Cable Tap BoxDown LF3HC08CBST
Accessories End Box LF3HC06EBST Accessories End Box LF3HC08EBST
Accessories Flanged End w/Lugs LF3HC06FLST Accessories Flanged End w/Lugs LF3HC08FLST
Accessories Flanged End LF3HC06FEST Accessories Flanged End LF3HC08FEST
Fittings Expansion LengthUp LF3HC06XUST Fittings Expansion LengthUp LF3HC08XUST
Fittings Expansion LengthDown LF3HC06XDST Fittings Expansion LengthDown LF3HC08XDST
Fittings Total Phase Transposition LF3HC06TFST Fittings Total Phase Transposition LF3HC08TFST
Fittings TeeRight LF3HC06TRST Fittings TeeRight LF3HC08TRST
Fittings TeeLeft LF3HC06TLST Fittings TeeLeft LF3HC08TLST
Fittings TeeUp LF3HC06TUST Fittings TeeUp LF3HC08TUST
Fittings TeeDown LF3HC06TDST Fittings TeeDown LF3HC08TDST
Fittings Off SetUp (6) LF3HC06OU06 Fittings Off SetUp (6) LF3HC08OU06
Fittings Off SetUp (12) LF3HC06OU12 Fittings Off SetUp (12) LF3HC08OU12
Fittings Off SetUp (18) LF3HC06OU18 Fittings Off SetUp (18) LF3HC08OU18
Fittings Off SetDown (6) LF3HC06OD06 Fittings Off SetDown (6) LF3HC08OD06
Fittings Off SetDown (12) LF3HC06OD12 Fittings Off SetDown (12) LF3HC08OD12
Fittings Off SetDown (18) LF3HC06OD18 Fittings Off SetDown (18) LF3HC08OD18
Fittings Off SetLeft (6) LF3HC06OL06 Fittings Off SetLeft (6) LF3HC08OL06
Fittings Off SetLeft (12) LF3HC06OL12 Fittings Off SetLeft (12) LF3HC08OL12
Fittings Off SetLeft (18) LF3HC06OL18 Fittings Off SetLeft (18) LF3HC08OL18
Fittings Off SetRight (6) LF3HC06OR06 Fittings Off SetRight (6) LF3HC08OR06
Fittings Off SetRight (12) LF3HC06OR12 Fittings Off SetRight (12) LF3HC08OR12
Fittings Off Set Right (18) LF3HC06OR18 Fittings Off Set Right (18) LF3HC08OR18
225 Amps Three-Phase, Four-Wire Integrated Housing Ground 400 Amps Three-Phase, Four-Wire Integrated Housing Ground
Component Type Product Number Component Type Product Number
Linear Lengths Plug-In: 10-ft. LP4HC02SL10 Linear Lengths Plug-In: 10-ft. LP4HC04SL10
Linear Lengths Plug-In: 6-ft. LP4HC02SL06 Linear Lengths Plug-In: 6-ft. LP4HC04SL06
Linear Lengths Plug-In: 4-ft. LP4HC02SL04 Linear Lengths Plug-In: 4-ft. LP4HC04SL04
Linear Lengths Feeder: 10-ft. LF4HC02SL10 Linear Lengths Feeder: 10-ft. LF4HC04SL10
Linear Lengths Feeder: 5-ft. LF4HC02SL05 Linear Lengths Feeder: 5-ft. LF4HC04SL05
Linear Lengths Feeder: 3-ft. LF4HC02SL03 Linear Lengths Feeder: 3-ft. LF4HC04SL03
Linear Lengths Feeder: 2-ft. LF4HC02SL02 Linear Lengths Feeder: 2-ft. LF4HC04SL02
Linear Lengths Adjustable Straight Length LF4HC02ASST Linear Lengths Adjustable Straight Length LF4HC04ASST
Fittings Elbow Left 90 LF4HC02ELST Fittings Elbow Left 90 LF4HC04ELST
Fittings Elbow Right 90 LF4HC02ERST Fittings Elbow Right 90 LF4HC04ERST
Fittings Elbow Up 90 LF4HC02EUST Fittings Elbow Up 90 LF4HC04EUST
Fittings Elbow Down 90 LF4HC02EDST Fittings Elbow Down 90 LF4HC04EDST
Accessories End Cable Tap BoxUp LF4HC02TTST Accessories End Cable Tap BoxUp LF4HC04TTST
Accessories End Cable Tap BoxDown LF4HC02TBST Accessories End Cable Tap BoxDown LF4HC04TBST
Accessories Center Cable Tap BoxUp LF4HC02CTST Accessories Center Cable Tap BoxUp LF4HC04CTST
Accessories Center Cable Tap BoxDown LF4HC02CBST Accessories Center Cable Tap BoxDown LF4HC04CBST
Accessories End Box LF4HC02EBST Accessories End Box LF4HC04EBST
Accessories Flanged End w/Lugs LF4HC02FLST Accessories Flanged End w/Lugs LF4HC04FLST
Accessories Flanged End LF4HC02FEST Accessories Flanged End LF4HC04FEST
Fittings Expansion LengthUp LF4HC02XUST Fittings Expansion LengthUp LF4HC04XUST
Fittings Expansion LengthDown LF4HC02XDST Fittings Expansion LengthDown LF4HC04XDST
Fittings Total Phase Transposition LF4HC02TFST Fittings Total Phase Transposition LF4HC04TFST
Fittings TeeRight LF4HC02TRST Fittings TeeRight LF4HC04TRST
Fittings TeeLeft LF4HC02TLST Fittings TeeLeft LF4HC04TLST
Fittings TeeUp LF4HC02TUST Fittings TeeUp LF4HC04TUST
Fittings TeeDown LF4HC02TDST Fittings TeeDown LF4HC04TDST
Fittings Off SetUp (6) LF4HC02OU06 Fittings Off SetUp (6) LF4HC04OU06
Fittings Off SetUp (12) LF4HC02OU12 Fittings Off SetUp (12) LF4HC04OU12
Fittings Off SetUp (18) LF4HC02OU18 Fittings Off SetUp (18) LF4HC04OU18
Fittings Off SetDown (6) LF4HC02OD06 Fittings Off SetDown (6) LF4HC04OD06
Fittings Off SetDown (12) LF4HC02OD12 Fittings Off SetDown (12) LF4HC04OD12
Fittings Off SetDown (18) LF4HC02OD18 Fittings Off SetDown (18) LF4HC04OD18
Fittings Off SetLeft (6) LF4HC02OL06 Fittings Off SetLeft (6) LF4HC04OL06
Fittings Off SetLeft (12) LF4HC02OL12 Fittings Off SetLeft (12) LF4HC04OL12
Fittings Off SetLeft (18) LF4HC02OL18 Fittings Off SetLeft (18) LF4HC04OL18
Fittings Off SetRight (6) LF4HC02OR0 Fittings Off SetRight (6) LF4HC04OR06
Fittings Off SetRight (12) LF4HC02OR12 Fittings Off SetRight (12) LF4HC04OR12
Fittings Off Set Right (18) LF4HC02OR18 Fittings Off Set Right (18) LF4HC04OR18
600 Amps Three-Phase, Four-Wire Integrated Housing Ground 800 Amps Three-Phase, Four-Wire Integrated Housing Ground
Component Type Product Number Component Type Product Number
Linear Lengths Plug-In: 10-ft. LP4HC06SL10 Linear Lengths Plug-In: 10-ft. LP4HC08SL10
Linear Lengths Plug-In: 6-ft. LP4HC06SL06 Linear Lengths Plug-In: 6-ft. LP4HC08SL06
Linear Lengths Plug-In: 4-ft. LP4HC06SL04 Linear Lengths Plug-In: 4-ft. LP4HC08SL04
Linear Lengths Feeder: 10-ft. LF4HC06SL10 Linear Lengths Feeder: 10-ft. LF4HC08SL10
Linear Lengths Feeder: 5-ft. LF4HC06SL05 Linear Lengths Feeder: 5-ft. LF4HC08SL05
Linear Lengths Feeder: 3-ft. LF4HC06SL03 Linear Lengths Feeder: 3-ft. LF4HC08SL03
Linear Lengths Feeder: 2-ft. LF4HC06SL02 Linear Lengths Feeder: 2-ft. LF4HC08SL02
Linear Lengths Adjustable Straight Length LF4HC06ASST Linear Lengths Adjustable Straight Length LF4HC08ASST
Fittings Elbow Left 90 LF4HC06ELST Fittings Elbow Left 90 LF4HC08ELST
Fittings Elbow Right 90 LF4HC06ERST Fittings Elbow Right 90 LF4HC08ERST
Fittings Elbow Up 90 LF4HC06EUST Fittings Elbow Up 90 LF4HC08EUST
Fittings Elbow Down 90 LF4HC06EDST Fittings Elbow Down 90 LF4HC08EDST
Accessories End Cable Tap BoxUp LF4HC06TTST Accessories End Cable Tap BoxUp LF4HC08TTST
Accessories End Cable Tap BoxDown LF4HC06TBST Accessories End Cable Tap BoxDown LF4HC08TBST
Accessories Center Cable Tap BoxUp LF4HC06CTST Accessories Center Cable Tap BoxUp LF4HC08CTST
Accessories Center Cable Tap BoxDown LF4HC06CBST Accessories Center Cable Tap BoxDown LF4HC08CBST
Accessories End Box LF4HC06EBST Accessories End Box LF4HC08EBST
Accessories Flanged End w/Lugs LF4HC06FLST Accessories Flanged End w/Lugs LF4HC08FLST
Accessories Flanged End LF4HC06FEST Accessories Flanged End LF4HC08FEST
Fittings Expansion LengthUp LF4HC06XUST Fittings Expansion LengthUp LF4HC08XUST
Fittings Expansion LengthDown LF4HC06XDST Fittings Expansion LengthDown LF4HC08XDST
Fittings Total Phase Transposition LF4HC06TFST Fittings Total Phase Transposition LF4HC08TFST
Fittings TeeRight LF4HC06TRST Fittings TeeRight LF4HC08TRST
Fittings TeeLeft LF4HC06TLST Fittings TeeLeft LF4HC08TLST
Fittings TeeUp LF4HC06TUST Fittings TeeUp LF4HC08TUST
Fittings TeeDown LF4HC06TDST Fittings TeeDown LF4HC08TDST
Fittings Off SetUp (6) LF4HC06OU06 Fittings Off SetUp (6) LF4HC08OU06
Fittings Off SetUp (12) LF4HC06OU12 Fittings Off SetUp (12) LF4HC08OU12
Fittings Off SetUp (18) LF4HC06OU18 Fittings Off SetUp (18) LF4HC08OU18
Fittings Off SetDown (6) LF4HC06OD06 Fittings Off SetDown (6) LF4HC08OD06
Fittings Off SetDown (12) LF4HC06OD12 Fittings Off SetDown (12) LF4HC08OD12
Fittings Off SetDown (18) LF4HC06OD18 Fittings Off SetDown (18) LF4HC08OD18
Fittings Off SetLeft (6) LF4HC06OL06 Fittings Off SetLeft (6) LF4HC08OL06
Fittings Off SetLeft (12) LF4HC06OL12 Fittings Off SetLeft (12) LF4HC08OL12
Fittings Off SetLeft (18) LF4HC06OL18 Fittings Off SetLeft (18) LF4HC08OL18
Fittings Off SetRight (6) LF4HC06OR06 Fittings Off SetRight (6) LF4HC08OR06
Fittings Off SetRight (12) LF4HC06OR12 Fittings Off SetRight (12) LF4HC08OR12
Fittings Off Set Right (18) LF4HC06OR18 Fittings Off Set Right (18) LF4HC08OR18
225 Amps Three-Phase, Four-Wire Internal Copper Ground Bus 400 Amps Three-Phase, Four-Wire Internal Copper Ground Bus
Component Type Product Number Component Type Product Number
Linear Lengths Plug-In: 10-ft. LP4GC02SL10 Linear Lengths Plug-In: 10-ft. LP4GC04SL10
Linear Lengths Plug-In: 6-ft. LP4GC02SL06 Linear Lengths Plug-In: 6-ft. LP4GC04SL06
Linear Lengths Plug-In: 4-ft. LP4GC02SL04 Linear Lengths Plug-In: 4-ft. LP4GC04SL04
Linear Lengths Feeder: 10-ft. LF4GC02SL10 Linear Lengths Feeder: 10-ft. LF4GC04SL10
Linear Lengths Feeder: 5-ft. LF4GC02SL05 Linear Lengths Feeder: 5-ft. LF4GC04SL05
Linear Lengths Feeder: 3-ft. LF4GC02SL03 Linear Lengths Feeder: 3-ft. LF4GC04SL03
Linear Lengths Feeder: 2-ft. LF4GC02SL02 Linear Lengths Feeder: 2-ft. LF4GC04SL02
Linear Lengths Adjustable Straight Length LF4GC02ASST Linear Lengths Adjustable Straight Length LF4GC04ASST
Fittings Elbow Left 90 LF4GC02ELST Fittings Elbow Left 90 LF4GC04ELST
Fittings Elbow Right 90 LF4GC02ERST Fittings Elbow Right 90 LF4GC04ERST
Fittings Elbow Up 90 LF4GC02EUST Fittings Elbow Up 90 LF4GC04EUST
Fittings Elbow Down 90 LF4GC02EDST Fittings Elbow Down 90 LF4GC04EDST
Accessories End Cable Tap BoxUp LF4GC02TTST Accessories End Cable Tap BoxUp LF4GC04TTST
Accessories End Cable Tap BoxDown LF4GC02TBST Accessories End Cable Tap BoxDown LF4GC04TBST
Accessories Center Cable Tap BoxUp LF4GC02CTST Accessories Center Cable Tap BoxUp LF4GC04CTST
Accessories Center Cable Tap BoxDown LF4GC02CBST Accessories Center Cable Tap BoxDown LF4GC04CBST
Accessories End Box LF4GC02EBST Accessories End Box LF4GC04EBST
Accessories Flanged End w/Lugs LF4GC02FLST Accessories Flanged End w/Lugs LF4GC04FLST
Accessories Flanged End LF4GC02FEST Accessories Flanged End LF4GC04FEST
Fittings Expansion LengthUp LF4GC02XUST Fittings Expansion LengthUp LF4GC04XUST
Fittings Expansion LengthDown LF4GC02XDST Fittings Expansion LengthDown LF4GC04XDST
Fittings Total Phase Transposition LF4GC02TFST Fittings Total Phase Transposition LF4GC04TFST
Fittings TeeRight LF4GC02TRST Fittings TeeRight LF4GC04TRST
Fittings TeeLeft LF4GC02TLST Fittings TeeLeft LF4GC04TLST
Fittings TeeUp LF4GC02TUST Fittings TeeUp LF4GC04TUST
Fittings TeeDown LF4GC02TDST Fittings TeeDown LF4GC04TDST
Fittings Off SetUp (6) LF4GC02OU06 Fittings Off SetUp (6) LF4GC04OU06
Fittings Off SetUp (12) LF4GC02OU12 Fittings Off SetUp (12) LF4GC04OU12
Fittings Off SetUp (18) LF4GC02OU18 Fittings Off SetUp (18) LF4GC04OU18
Fittings Off SetDown (6) LF4GC02OD06 Fittings Off SetDown (6) LF4GC04OD06
Fittings Off SetDown (12) LF4GC02OD12 Fittings Off SetDown (12) LF4GC04OD12
Fittings Off SetDown (18) LF4GC02OD18 Fittings Off SetDown (18) LF4GC04OD18
Fittings Off SetLeft (6) LF4GC02OL06 Fittings Off SetLeft (6) LF4GC04OL06
Fittings Off SetLeft (12) LF4GC02OL12 Fittings Off SetLeft (12) LF4GC04OL12
Fittings Off SetLeft (18) LF4GC02OL18 Fittings Off SetLeft (18) LF4GC04OL18
Fittings Off SetRight (6) LF4GC02OR06 Fittings Off SetRight (6) LF4GC04OR06
Fittings Off SetRight (12) LF4GC02OR12 Fittings Off SetRight (12) LF4GC04OR12
Fittings Off Set Right (18) LF4GC02OR18 Fittings Off SetRight (18) LF4GC04OR18
600 Amps Three-Phase, Four-Wire Internal Copper Ground Bus 800 Amps Three-Phase, Four-Wire Internal Copper Ground Bus
Component Type Product Number Component Type Product Number
Linear Lengths Plug-In: 10-ft. LP4GC06SL10 Linear Lengths Plug-In: 10-ft. LP4GC08SL10
Linear Lengths Plug-In: 6-ft. LP4GC06SL06 Linear Lengths Plug-In: 6-ft. LP4GC08SL06
Linear Lengths Plug-In: 4-ft. LP4GC06SL04 Linear Lengths Plug-In: 4-ft. LP4GC08SL04
Linear Lengths Feeder: 10-ft. LF4GC06SL10 Linear Lengths Feeder: 10-ft. LF4GC08SL10
Linear Lengths Feeder: 5-ft. LF4GC06SL05 Linear Lengths Feeder: 5-ft. LF4GC08SL05
Linear Lengths Feeder: 3-ft. LF4GC06SL03 Linear Lengths Feeder: 3-ft. LF4GC08SL03
Linear Lengths Feeder: 2-ft. LF4GC06SL02 Linear Lengths Feeder: 2-ft. LF4GC08SL02
Linear Lengths Adjustable Straight Length LF4GC06ASST Linear Lengths Adjustable Straight Length LF4GC08ASST
Fittings Elbow Left 90 LF4GC06ELST Fittings Elbow Left 90 LF4GC08ELST
Fittings Elbow Right 90 LF4GC06ERST Fittings Elbow Right 90 LF4GC08ERST
Fittings Elbow Up 90 LF4GC06EUST Fittings Elbow Up 90 LF4GC08EUST
Fittings Elbow Down 90 LF4GC06EDST Fittings Elbow Down 90 LF4GC08EDST
Accessories End Cable Tap BoxUp LF4GC06TTST Accessories End Cable Tap BoxUp LF4GC08TTST
Accessories End Cable Tap BoxDown LF4GC06TBST Accessories End Cable Tap BoxDown LF4GC08TBST
Accessories Center Cable Tap BoxUp LF4GC06CTST Accessories Center Cable Tap BoxUp LF4GC08CTST
Accessories Center Cable Tap BoxDown LF4GC06CBST Accessories Center Cable Tap BoxDown LF4GC08CBST
Accessories End Box LF4GC06EBST Accessories End Box LF4GC08EBST
Accessories Flanged End w/Lugs LF4GC06FLST Accessories Flanged End w/Lugs LF4GC08FLST
Accessories Flanged End LF4GC06FEST Accessories Flanged End LF4GC08FEST
Fittings Expansion LengthUp LF4GC06XUST Fittings Expansion LengthUp LF4GC08XUST
Fittings Expansion LengthDown LF4GC06XDST Fittings Expansion LengthDown LF4GC08XDST
Fittings Total Phase Transposition LF4GC06TFST Fittings Total Phase Transposition LF4GC08TFST
Fittings TeeRight LF4GC06TRST Fittings TeeRight LF4GC08TRST
Fittings TeeLeft LF4GC06TLST Fittings TeeLeft LF4GC08TLST
Fittings TeeUp LF4GC06TUST Fittings TeeUp LF4GC08TUST
Fittings TeeDown LF4GC06TDST Fittings TeeDown LF4GC08TDST
Fittings Off SetUp (6) LF4GC06OU06 Fittings Off SetUp (6) LF4GC08OU06
Fittings Off SetUp (12) LF4GC06OU12 Fittings Off SetUp (12) LF4GC08OU12
Fittings Off SetUp (18) LF4GC06OU18 Fittings Off SetUp (18) LF4GC08OU18
Fittings Off SetDown (6) LF4GC06OD06 Fittings Off SetDown (6) LF4GC08OD06
Fittings Off SetDown (12) LF4GC06OD12 Fittings Off SetDown (12) LF4GC08OD12
Fittings Off SetDown (18) LF4GC06OD18 Fittings Off SetDown (18) LF4GC08OD18
Fittings Off SetLeft (6) LF4GC06OL06 Fittings Off SetLeft (6) LF4GC08OL06
Fittings Off SetLeft (12) LF4GC06OL12 Fittings Off SetLeft (12) LF4GC08OL12
Fittings Off SetLeft (18) LF4GC06OL18 Fittings Off SetLeft (18) LF4GC08OL18
Fittings Off SetRight (6) LF4GC06OR06 Fittings Off SetRight (6) LF4GC08OR06
Fittings Off SetRight (12) LF4GC06OR12 Fittings Off SetRight (12) LF4GC08OR12
Fittings Off Set Right (18) LF4GC06OR18 Fittings Off Set Right (18) LF4GC08OR18
Low-Tier Frames Three-Phase, Four-Wire SFHA Mid-Tier Frames Three-Phase, Four-Wire SFLA
Short Circuit Short Circuit Short Circuit Short Circuit Short Circuit Short Circuit
Trip Rating Rating Rating Product Trip Rating Rating Rating Product
Amps @ 240V (kAIC) @ 480V (kAIC) @ 600V (kAIC) Number Amps @ 240V (kAIC) @ 480V (kAIC) @ 600V (kAIC) Number
70 65 25 18 SL47SFHG 70 100 65 25 SL47SFLG
90 65 25 18 SL49SFHG 90 100 65 25 SL49SFLG
100 65 25 18 SL410SFHG 100 100 65 25 SL410SFLG
110 65 25 18 SL411SFHG 110 100 65 25 SL411SFLG
125 65 25 18 SL412SFHG 125 100 65 25 SL412SFLG
150 65 25 18 SL415SFHG 150 100 65 25 SL415SFLG
175 65 25 18 SL417SFHG 175 100 65 25 SL417SFLG
200 65 25 18 SL420SFHG 200 100 65 25 SL420SFLG
225 65 25 18 SL422SFHG 225 100 65 25 SL422SFLG
250 65 25 18 SL425SFHG 250 100 65 25 SL425SFLG
Mid-Tier Frames Three-Phase, Three-Wire SELA Without Rating Plug Three-Phase, Three-Wire
Short Circuit Short Circuit Short Circuit Frame Type Trip Amps Product Number
Trip Rating Rating Rating Product
Amps @ 240V (kAIC) @ 480V (kAIC) @ 600V (kAIC) Number SEDGA 15-30 SL301SEDG
SEDGA 40-60 SL302SEDG
15 100 65 25 SL31SELG SEDGA 70-100 SL303SEDG
20 100 65 25 SL32SELG SEDGA 110-150 SL304SEDG
30 100 65 25 SL33SELG SEHGA 15-30 SL301SEHG
40 100 65 25 SL34SELG SEHGA 40-60 SL302SEHG
50 100 65 25 SL35SELG SEHGA 70-100 SL303SEHG
60 100 65 25 SL36SELG SEHGA 110-150 SL304SEHG
70 100 65 25 SL37SELG SFHGA 70-250 SL300SFHG
80 100 65 25 SL38SELG SELGA 15-30 SL301SELG
90 100 65 25 SL39SELG SELGA 40-60 SL302SELG
100 100 65 25 SL310SELG SELGA 70-100 SL303SELG
110 100 65 25 SL311SELG SELGA 110-150 SL304SELG
125 100 65 25 SL312SELG SFLGA 70-250 SL300SFLG
150 100 65 25 SL315SELG SEPGA 15-30 SL301SEPG
SEPGA 40-60 SL302SEPG
SEPGA 70-100 SL303SEPG
SEPGA 110-150 SL304SEPG
Mid-Tier Frames Three-Phase, Three-Wire SFLA
Short Circuit Short Circuit Short Circuit
Trip Rating Rating Rating Product
Amps @ 240V (kAIC) @ 480V (kAIC) @ 600V (kAIC) Number Without Rating Plug Three-Phase, Four-Wire
70 100 65 25 SL37SFLG Frame Type Trip Amps Product Number
90 100 65 25 SL39SFLG
SEDA 15-30 SL401SEDG
100 100 65 25 SL310SFLG
SEDA 40-60 SL402SEDG
110 100 65 25 SL311SFLG
SEDA 70-100 SL403SEDG
125 100 65 25 SL312SFLG
SEDA 110-150 SL404SEDG
150 100 65 25 SL315SFLG
SEHA 15-30 SL401SEHG
175 100 65 25 SL317SFLG
SEHA 40-60 SL402SEHG
200 100 65 25 SL320SFLG
SEHA 70-100 SL403SEHG
225 100 65 25 SL322SFLG
SEHA 110-150 SL404SEHG
250 100 65 25 SL325SFLG
SFHA 70-250 SL400SFHG
SELA 15-30 SL401SELG
SELA 40-60 SL402SELG
Mid-Tier Frames Three-Phase, Four-Wire SELA SELA 70-100 SL403SELG
SELA 110-150 SL404SELG
Short Circuit Short Circuit Short Circuit SFLA 70-250 SL400SFLG
Trip Rating Rating Rating Product
Amps @ 240V (kAIC) @ 480V (kAIC) @ 600V (kAIC) Number
15 100 65 25 SL41SELG
20 100 65 25 SL42SELG
30 100 65 25 SL43SELG
40 100 65 25 SL44SELG
50 100 65 25 SL45SELG
60 100 65 25 SL46SELG
70 100 65 25 SL47SELG
80 100 65 25 SL48SELG
90 100 65 25 SL49SELG
100 100 65 25 SL410SELG
110 100 65 25 SL411SELG
125 100 65 25 SL412SELG
150 100 65 25 SL415SELG
Circuit Breaker Plugs - Standard Frames Three-Phase, Circuit Breaker Plugs - Standard Frames Three-Phase,
Three-Wire TEB Four-Wire TED4
Short Circuit Rating Product Trip Short Circuit Rating Short Circuit Rating Product
Trip Amps @ 240V (kAIC) Number Amps @ 240V (kAIC) @ 480V (kAIC) Number
15 10 SL31EBG 15 18 14 SL41ED4G
20 10 SL32EBG 20 18 14 SL42ED4G
30 10 SL33EBG 30 18 14 SL43ED4G
40 10 SL34EBG 40 18 14 SL44ED4G
50 10 SL35EBG 50 18 14 SL45ED4G
60 10 SL36EBG 60 18 14 SL46ED4G
70 10 SL37EBG 70 18 14 SL47ED4G
100 10 SL310EBG 100 18 14 SL410ED4G
Circuit Breaker Plugs - Standard Frames Three-Phase, Circuit Breaker Plugs - Standard Frames Three-Phase,
Three-Wire TED4 Four-Wire TED6
Trip Short Circuit Rating Short Circuit Rating Product Short Circuit Short Circuit Short Circuit
Amps @ 240V (kAIC) @ 480V (kAIC) Number Trip Rating Rating Rating Product
Amps @ 240V (kAIC) @ 480V (kAIC) @ 600V (kAIC) Number
15 18 14 SL31ED4G
20 18 14 SL32ED4G 15 18 14 14 SL41ED6G
30 18 14 SL33ED4G 20 18 14 14 SL42ED6G
40 18 14 SL34ED4G 30 18 14 14 SL43ED6G
50 18 14 SL35ED4G 40 18 14 14 SL44ED6G
60 18 14 SL36ED4G 50 18 14 14 SL45ED6G
70 18 14 SL37ED4G 60 18 14 14 SL46ED6G
100 18 14 SL310ED4G 70 18 14 14 SL47ED6G
100 18 14 14 SL410ED6G
Adapter Kits
Convert Spectra Series LowAmp plugs to Spectra Series Bus.
Ground stabs included.
Amperage Product Number
30-100 SLSB1G
200-250 SLSB4G
400-600 SLSB5G
Adapter Kits
Convert Spectra Series Bus Plugs to Spectra LowAmp Bus.
(Style 2shipped after 5/95.) Ground stabs included.
Amperage Product Number
30-100 SBSL1G
200-225 SBSL4G
400-600 SBSL5G
Adapter Kits
Convert Armor-Clad to Spectra Series LowAmp
(Style 8 shipped after 5/95.) Ground stabs included.
Amperage Product Number
30-100 ACSL1G
200-225 ACSL4G
400 ACSL5G
Spring Riser
Linear Lengths Three-Phase, Four-Wire
Plug-In and Feeder. All Bus are UL listed at 600 Volts
Conductor A Width Bar Sizes - DC Ampere Approx. Weight Approx. Weight
Material Amperage (inches, mm) Width x Thickness (in.) Rating Lbs./Ft. Kg/M
Aluminum 225 Amps 3 (76) .750 x .250 225 5.4 8
Aluminum 400 Amps 3 3/8 (86) 1.125 x .250 600 6 8.9
Aluminum 600 Amps 4 (102) 1.750 x .250 800 7.5 11.2
Aluminum 800 Amps 5 (127) 2.875 x .250 1200 10 14.9
Copper 225 Amps 3 (76) .750 x .250 225 7.4 11
Copper 400 Amps 3 (76) .750 x .250 600 7.4 11
Copper 600 Amps 3 3/8 (86) 1.125 x .250 800 9.2 13.7
Copper 800 Amps 4 (102) 1.750 x .250 1200 12.2 18.2 (Standard) Flatwise Hanger
1DC Bus. is 4-wire with + + polarity. Shipped with Each Straight Length
Conversion Chart
Decimal Fraction
.12 1/8
.63 5/8
.88 7/8
Floor/Wall Flange Cutout and Drilling Detail Standard Center Cable Tap Box Down Position, Side View
Bar Width (mm) Dimension X (mm) Dimension Y (mm)
.750 5.000 8.500
1.125 5.375 8.875
1.750 6.000 9.500
2.875 7.125 10.625
Note: Floor or wall opening should provide 1/2" clearance all around the Busway.
End Box
Figure A
Fusible Switches Outer Dimensions Door hinges at left end. All dimensions
are shown over largest part of plug.
Type QMR
Weight Width Length (in.) Length (in.) Depth Figure
Voltage Amperage (Lbs.) (in.) Standard Gutter Extended Gutter (in.) No.
240 and 600 30 24 11.25 13 18.63 8.75 A
240 and 600 60 25 11.25 13 18.63 8.75 A
240 and 600 100 28 11.25 18.75 N/A 8.75 A
240 and 600 200 46 16 18.75 24.5 8.75 A
240 and 600 400 135 20.5 18.75 N/A 18.75 B
Figure B
Door hinges at top. All dimensions
are shown over largest part of plug.
Up 90 Elbow Shown (Down 90 Elbow Reversed) Offset Right Shown (Left Offset Reversed)
Offset Down Shown (Offset Up Reversed) Tee Right Shown (Left Tee Reversed)
Tee Down Shown (Up Tee Reversed) Elbow 90 Right Shown (Left Elbow Reversed)
wide variety of indoor locations where there is a need for small Linear Lengths 10-ft. DP3HA01SL10
Linear Lengths 6 ft. DP3HA01SL06
blocks of conveniently available power. Type DH busway has a Linear Lengths 2-ft. DP3HA01SL02
lower installed cost than wire and conduit, yet has all the advan- Accessories End Tap Boxes DP3HA01TSST
tages and features of plug-in busway. Available Ratings: 100 Straight Bar end
Accessories End Tap Boxes DP3HA01TOST
amperes, 600 volts, indoor enclosures only. Offset Bar End
Accessories Center (Joint) DP3HA01CCST
Tap Boxes
Accessories End (Stub) Straight DP3HA01SSST
Applications Bar end
Type DH busway provides a ready power source for small Fittings Offset Bar End DP3HA01SOST
Devices Common to All Three- and Four-Wire Systems Devices Common to All Three- and Four-Wire Systems
Standard Internal Ground Bar
Component Type Product Number Component Type Product Number
Fittings Elbows Up DP4HA01EUST Fittings Elbows Up DP4GA01EUST
Fittings Elbows Down DP4HA01EDST Fittings Elbows Down DP4GA01EDST
Fittings Elbows Left DP4HA01ELST Fittings Elbows Left DP4GA01ELST
Fittings Elbows Right DP4HA01ERST Fittings Elbows Right DP4GA01ERST
Fittings Tees Up DP4HA01TUST Fittings Tees Up DP4GA01TUST
Fittings Tees Down DP4HA01TDST Fittings Tees Down DP4GA01TDST
Fittings Tees Left DP4HA01TLST Fittings Tees Left DP4GA01TLST
Fittings Tees Right DP4HA01TRST Fittings Tees Right DP4GA01TRST
Fittings Crosses Up-Down DP4HA01CDST Fittings Crosses Left-Right DP4GA01CLST
Fittings Crosses Left-Right DP4HA01CLST Fittings Crosses Up-Down DP4GA01CDST
Fittings Reverse Fittings Straight DP4HA01RSST Fittings Reverse Fittings Straight DP4GA01RSST
Bar End Bar End
Fittings Reverse Fittings DP4HA01ROST Fittings Reverse Fittings DP4GA01ROST
Offset Bar End Offset Bar End
Linear Lengths Adjustable Lengths DP4HA01ASST Linear Lengths Adjustable Lengths DP4GA01ASST
Accessories End Boxes DP4HA01EBST Accessories End Boxes DP4GA01EBST
Accessories Flanges DH1F Accessories Flanges DH1F
Accessories Outlet Covers DH10C Accessories Outlet Covers DH10C
Accessories Hangers (Edgewise) DE1HES Accessories Hangers (Edgewise) DE1HES
Single Run Single Run
Accessories Hangers (Edgewise) Single DH1HU1 Accessories Hangers (Edgewise) Single DH1HU1
Run (wall/ceiling mtg.) Run (wall/ceiling mtg.)
Accessories Hangers (Edgewise) DE1HED Accessories Hangers (Edgewise) DE1HED
Double Run Double Run
wide variety of indoor locations where there is a need for small Linear Lengths 10-ft. DP3HC01SL10
Linear Lengths 6 ft. DP3HC01SL06
blocks of conveniently available power. Type DH busway has a Linear Lengths 2-ft. DP3HC01SL02
lower installed cost than wire and conduit, yet has all the advan- Accessories End Tap Boxes DP3HC01TSST
tages and features of plug-in busway. Available Ratings: 100 Straight Bar end
Accessories End Tap Boxes DP3HC01TOST
amperes, 600 volts, indoor enclosures only. Offset Bar End
Accessories Center (Joint) DP3HC01CCST
Tap Boxes
Accessories End (Stub) Straight DP3HC01SSST
Applications Bar end
Type DH busway provides a ready power source for small Fittings Offset Bar End DP3HC01SOST
Devices Common to All Three- and Four-Wire Systems Devices Common to All Three- and Four-Wire Systems
Standard Internal Ground Bar
Component Type Product Number Component Type Product Number
Fittings Elbows Up DP4HC01EUST Fittings Elbows Up DP4GC01EUST
Fittings Elbows Down DP4HC01EDST Fittings Elbows Down DP4GC01EDST
Fittings Elbows Left DP4HC01ELST Fittings Elbows Left DP4GC01ELST
Fittings Elbows Right DP4HC01ERST Fittings Elbows Right DP4GC01ERST
Fittings Tees Up DP4HC01TUST Fittings Tees Up DP4GC01TUST
Fittings Tees Down DP4HC01TDST Fittings Tees Down DP4GC01TDST
Fittings Tees Left DP4HC01TLST Fittings Tees Left DP4GC01TLST
Fittings Tees Right DP4HC01TRST Fittings Tees Right DP4GC01TRST
Fittings Crosses Up-Down DP4HC01CDST Fittings Crosses Up-Down DP4GC01CDST
Fittings Crosses Left-Right DP4HC01CLST Fittings Crosses Left-Right DP4GC01CLST
Fittings Reverse Fittings Straight DP4HC01RSST Fittings Reverse Fittings Straight DP4GC01RSST
Bar End Bar End
Fittings Reverse Fittings DP4HC01ROST Fittings Reverse Fittings DP4GC01ROST
Offset Bar End Offset Bar End
Linear Lengths Adjustable Lengths DP4HC01ASST Linear Lengths Adjustable Lengths DP4GC01ASST
Accessories End Boxes DP4HC01EBST Accessories End Boxes DP4GC01EBST
Accessories Flanges DH1F Accessories Flanges DH1F
Accessories Outlet Covers DH10C Accessories Outlet Covers DH10C
Accessories Hangers (Edgewise) DE1HES Accessories Hangers (Edgewise) DE1HES
Single Run Single Run
Accessories Hangers (Edgewise) Single DH1HU1 Accessories Hangers (Edgewise) Single DH1HU1
Run (wall/ceiling mtg.) Run (wall/ceiling mtg.)
Accessories Hangers (Edgewise) DE1HED Accessories Hangers (Edgewise) DE1HED
Double Run Double Run
(With Space Only for Three THQL Breaker Poles) Handle-Operated Type TQL
Order breakers separately.
1C in Product Number indicates screw tightening housing clips.
D P 3 H C 01 SL 02
Description Code
Product DH - Busway D Configurations Code Type Feet Code
Type Plug-In P Straight Length SL 2 02
1PH, 3W 1 ElbowLeft EL Plug-In 6 06
Service 3PH, 3W 3 ElbowRight ER 10 10
3PH, 4W 100% Neutral 4 ElbowUp EU Fittings NA ST
Integrated Housing H ElbowDown ED
Ground
Internal Bus G Center Cable Tap Box CC
Copper C End Cable Tap Box Straight Bar TS
Conductor
Aluminum A End Cable Tap Box Offset Bar TO
End Stub Straight Bar SS
Amps Code End Stub Off-set Bar SO
100 01 End Box EB
TeeRight TR
TeeLeft TL
TeeDown TD
TeeUp TU
Cross Up/Down CD
Cross Left/Right CL
Adjustable Straight Length AS
Reverse Fitting Straight Bar RS
Reverse Fitting Offset Bar RO
End Stub Center Joint Tap Box Elbow Down Tee Down
Linear Lengths Single Run (wall/ceiling mtg) Elbow Left Tee Left
Hanger
Tap Box-Straight Bar End Hanger Edgewise Elbow Right Tee Right
Busway Section 13
Lighting Busway
Type LTG
Plug-in
Application
for convenient distribution of power for lighting or similar light- Feed-In Boxes 4 1 DFEB422
Surface Mounting
duty loads. End
Feed-In Boxes 4 1 DFCB422
Surface Mounting
Available Ratings Center
Feed-In Boxes 5 1 DAOCBB422
Amperes: 50 amperes Suspended Mounting
Voltage: 300 Volts or less, AC or DC Center
DAOCSC4222
Feed-In Boxes 5 1
E
LE T
Busing: Copper Suspended Mounting
Service Type: Three-phase, four-wire Sectionalizing
Enclosures: Indoor only Feed-In Boxes
Underslung Mounting
6
B SO 1 DASCBB422
Center
Feed-In Boxes 6
O 1 DASCSB4222
Application Underslung Mounting
Sectionalizing
Type LTG busway is designed for use on three-phase, four-wire 1See page 13-80.
systems that are rated 300 Volts or less. It is available in five- and 2Not UL listed.
ten-foot lengths only.
Fittings
Ordering Type Figure No.1 Std. Pkg. Product Number
E
LE T
Type LTG is ordered by product number. Two hangers should be Elbows Edgewise, 9 1 DAIEB422
included for each ten feet of busway, and these must be priced Internal
Elbows Edgewise, 10
SO 1 DAEEB422
OB
separately. Coupling sets are required to connect busway External
sections, feed-in boxes, or elbows, and these must be ordered Elbows Flat, Internal 8 1 DAIFEB422
separately. Elbows Flat, External 7 1 DAOFEB422
10 feet
5 feet OBSOLETE
1
1
1
1
DLTGB422
DLTGB4225
Hanger Plate (Only
with Screws for
Surface-Mounting
11 1 DLTGF
OL
Hook
Order one coupling set for each busway length, feed-in box, and elbow. Combination Rod and 12
S 1 DLTGMF3
OB
1See page 13-80. Messenger Cable Hanger
Fixture Hook 15 1 DLTGFH
OL
Service Type Amperage Voltage Contact Std. Pkg. Number
S
OB
4-pole 20 240 AC A-B 1 DATRP4213
3Includes cable clamp and ground terminal.
Unfused Plugs Terminal and Receptacle (Includes Type THQL circuit breakers.)
Service Figure Bus Bar Std. Product
Type No.1 Amperage Voltage Contact Pkg. Number
2-pole 16 20 120Vac A-N 20 DATRP2214AG2
(Terminal), (Terminal),
15 120Vac/
(Receptacle) 240Vdc
(Receptacle)
2-pole 16 20 240Vac B-N 20 DATRP2214BG2
(Terminal), (Terminal),
15 120Vac/
(Receptacle) 240Vdc
(Receptacle)
2-pole 16 15 125Vdc C-N 20 DATRP2214CG2
(Terminal), (Terminal),
15 120Vac/
(Receptacle) 240Vdc
(Receptacle)
1See page 13-80.
2Includes cable clamp and ground terminal.
O L
Voltage Contact Pkg. Number
4-pole 18 20
S 240Vac A-B-C-N 1 DFC421
1See page 13-80.
Fuses not included.
OB
Circuit Breaker Plugs One Single-Pole Breaker
Service Figure Bus Bar Std. Product
Type No.1 Amperage Voltage Contact Pkg. Number
2-pole 19 15 120Vac A-N 1 DATLB21154A
2-pole 19 15 120Vac B-N 1 DATLB21154B
2-pole 19 15 120Vac C-N 1 DATLB21154C
2-pole 19 20 120Vac A-N 1 DATLB21204A
2-pole 19 20 120Vac B-N 1 DATLB21204B
2-pole 19 20 120Vac C-N 1 DATLB21204C
2-pole 19 20 120Vac A-N 1 DATLB21203
1See page 13-80.
3On a three wire system the plug can contact either the A-N or the B-N.
ET E ET E
S OL S OL
OB OB
Fig. 1 Fig. 6 Fig. 11 Fig. 16
ET E ET E
O L O L
S S
OB OB
Fig. 2 Fig. 7 Fig. 12 Fig. 17
ET E ET E
O L O L
S S
OB OB
Fig. 3 Fig. 8 Fig. 13 Fig. 18
ET E
O L
S
OB
ET E ET E ET E
O L O L O L
S S S
OB OB OB
Fig. 5 Fig. 10 Fig. 15
Short-Circuit Ratings
For bus plug short-circuit ratings, see Spectra ratings on page 13-4.
Ordering
Prior to ordering transition pieces and accessories, you will need
to obtain the following information to ensure compatibility with
your existing Armor-Clad busway system:
Material: Aluminum or Copper bus bars? Armor-Clad to Spectra to Armor-Clad Transition
Ground bar: Optional copper ground bar? (Standard 5-foot length; call for custom lengths.)
Service: 3- or 4-wire system?
Amperes: What ampere is required?
Phase: What is A phase location?
Joint Type: Bolt-in or Slot-in joint?
Plug Dimensions
For bus plug dimensions and weights, see Spectra plugs on
page 13-35.
Armor-Clad Nomenclature
E T EProduct Number
S O
70
100
L AC37FKG
AC310FKG
B
600 Volts Inter. Trip 125 AC312FKG
Interlockto insure that plug is off when engaging bus and
when removing plug.
Door Interlockplug must be off to open door.
600 Volts Inter. Trip
600 Volts Inter. Trip
600 Volts Inter. Trip O 150
200
225
AC315FKG
AC320FKG
AC322FKG
Voltage Trip Amps Product Number 600 Volts Inter. Trip 125 AC312JK4G
600 Volts Inter. Trip 150 AC315JK4G
480 Volts Fixed Trip 15 AC31ED4G 600 Volts Inter. Trip 175 AC317JK4G
480 Volts Fixed Trip 20 AC32ED4G 600 Volts Inter. Trip 200 AC320JK4G
480 Volts Fixed Trip 30 AC33ED4G 600 Volts Inter. Trip 225 AC322JK4G
480 Volts Fixed Trip 40 AC34ED4G 600 Volts Inter. Trip 300 AC330JK4G
480 Volts Fixed Trip 50 AC35ED4G 600 Volts Inter. Trip 400 AC340JK4G
480 Volts Fixed Trip 60 AC36ED4G
480 Volts Fixed Trip 70 AC37ED4G
480 Volts Fixed Trip 100 AC310ED4G
Standard Frames Three-Phase, Three-Wire TJK6
Voltage Trip Amps Product Number
Standard Frames Three-Phase, Three-Wire TED6 600 Volts Inter. Trip 400 AC340JK6G
Voltage Trip Amps Product Number 600 Volts Inter. Trip 450 AC345JK6G
600 Volts Inter. Trip 500 AC350JK6G
600 Volts Fixed Trip 15 AC31ED6G 600 Volts Inter. Trip 600 AC360JK6G
600 Volts Fixed Trip 20 AC32ED6G
600 Volts Fixed Trip 30 AC33ED6G
600 Volts Fixed Trip 40 AC34ED6G
600 Volts Fixed Trip 50 AC35ED6G Standard Frames Three-Phase, Three-Wire TKM8
ETE
600 Volts Fixed Trip 70 AC37ED6G
Voltage Trip Amps Product Number
600 Volts Fixed Trip 100 AC310ED6G
600 Volts Inter. Trip
600 Volts Inter. Trip
600 Volts Inter. Trip
S O L
300
400
500
AC330KMG
AC340KMG
AC350KMG
OB
Standard Frames Three-Phase, Three-Wire TFJ 600 Volts Inter. Trip 600 AC360KMG
ETE
Voltage Trip Amps Product Number 600 Volts Inter. Trip 700 AC370KMG
600 Volts Inter. Trip 800 AC380KMG
600 Volts Fixed Trip 70 AC37FJG
600 Volts Fixed Trip
600 Volts Fixed Trip
S O L
100
110
AC310FJG
AC311FJG
OB
600 Volts Fixed Trip 125 AC312FJG
600 Volts Fixed Trip 150 AC315FJG
600 Volts Fixed Trip 200 AC320FJG
600 Volts Fixed Trip 225 AC322FJG
Standard Frames Three-Phase, Four-Wire TEB Standard Frames Three-Phase, Four-Wire TJJ
Voltage Trip Amps Product Number Voltage Trip Amps Product Number
240 Volts Fixed Trip 15 AC41EBG 600 Volts Fixed Trip 125 AC412JJG
240 Volts Fixed Trip 20 AC42EBG 600 Volts Fixed Trip 150 AC415JJG
240 Volts Fixed Trip 30 AC43EBG 600 Volts Fixed Trip 200 AC420JJG
240 Volts Fixed Trip 40 AC44EBG 600 Volts Fixed Trip 225 AC422JJG
240 Volts Fixed Trip 50 AC45EBG 600 Volts Fixed Trip 300 AC430JJG
240 Volts Fixed Trip 70 AC47EBG 600 Volts Fixed Trip 400 AC440JJG
240 Volts Fixed Trip 100 AC410EBG
ETE
600 Volts Fixed Trip 100 AC410ED6G Voltage Trip Amps Product Number
600 Volts Inter. Trip 300 AC430KMG
S O L
400
500
AC440KMG
AC450KMG
OB
600 Volts Inter. Trip 600 AC460KMG
Voltage
600 Volts Fixed Trip
Trip Amps
70
E T E Product Number
AC47FJG
600 Volts Inter. Trip
600 Volts Inter. Trip
700
800
AC470KMG
AC480KMG
600 Volts Fixed Trip
600 Volts Fixed Trip
S O
100
110
L AC410FJG
AC411FJG
600 Volts Fixed Trip
600 Volts Fixed Trip
600 Volts Fixed Trip
600 Volts Fixed Trip O B 125
150
200
225
AC412FJG
AC415FJG
AC420FJG
AC422FJG
E T E Product Number
600 Volts Inter. Trip
600 Volts Inter. Trip
S O
70
100
L AC47FKG
AC410FKG
B
600 Volts Inter. Trip 125 AC412FKG
O
600 Volts Inter. Trip 150 AC415FKG
600 Volts Inter. Trip 200 AC420FKG
600 Volts Inter. Trip 225 AC422FKG
Hi-Break Frames Three-Phase, Three-Wire THED Hi-Break Frames Three-Phase, Four-Wire THED
Voltage Trip Amps Product Number Voltage Trip Amps Product Number
600 Volts Fixed Trip 15 AC31HEDG 600 Volts Fixed Trip 15 AC41HEDG
600 Volts Fixed Trip 20 AC32HEDG 600 Volts Fixed Trip 20 AC42HEDG
600 Volts Fixed Trip 30 AC33HEDG 600 Volts Fixed Trip 30 AC43HEDG
600 Volts Fixed Trip 40 AC34HEDG 600 Volts Fixed Trip 40 AC44HEDG
600 Volts Fixed Trip 50 AC35HEDG 600 Volts Fixed Trip 50 AC45HEDG
600 Volts Fixed Trip 70 AC37HEDG 600 Volts Fixed Trip 70 AC47HEDG
600 Volts Fixed Trip 100 AC310HEDG 600 Volts Fixed Trip 100 AC410HEDG
Hi-Break Frames Three-Phase, Three-Wire THFK Hi-Break Frames Three-Phase, Four-Wire THFK
ETE ETE
Voltage Trip Amps Product Number Voltage Trip Amps Product Number
L L
600 Volts Inter. Trip 70 AC37HFKG 600 Volts Inter. Trip 70 AC47HFKG
O O
600 Volts Inter. Trip 100 AC310HFKG 600 Volts Inter. Trip 100 AC410HFKG
BS BS
600 Volts Inter. Trip 125 AC312HFKG 600 Volts Inter. Trip 125 AC412HFKG
600 Volts Inter. Trip 150 AC315HFKG 600 Volts Inter. Trip 150 AC415HFKG
600 Volts Inter. Trip
600 Volts Inter. Trip
O 200
225
AC320HFKG
AC322HFKG
600 Volts Inter. Trip
600 Volts Inter. Trip
O 200
225
AC420HFKG
AC422HFKG
Hi-Break Frames Three-Phase, Three-Wire THJK4 Hi-Break Frames Three-Phase, Four-Wire THJK4
Voltage Trip Amps Product Number Voltage Trip Amps Product Number
600 Volts Inter. Trip 125 AC312HJK4G 600 Volts Inter. Trip 125 AC412HJK4G
600 Volts Inter. Trip 150 AC315HJK4G 600 Volts Inter. Trip 150 AC415HJK4G
600 Volts Inter. Trip 200 AC320HJK4G 600 Volts Inter. Trip 200 AC420HJK4G
600 Volts Inter. Trip 225 AC322HJK4G 600 Volts Inter. Trip 225 AC422HJK4G
600 Volts Inter. Trip 300 AC330HJK4G 600 Volts Inter. Trip 300 AC430HJK4G
600 Volts Inter. Trip 400 AC340HJK4G 600 Volts Inter. Trip 400 AC440HJK4G
Hi-Break Frames Three-Phase, Three-Wire THJK6 Hi-Break Frames Three-Phase, Four-Wire THJK6
Voltage Trip Amps Product Number Voltage Trip Amps Product Number
600 Volts Inter. Trip 400 AC340HJK6G 600 Volts Inter. Trip 400 AC440HJK6G
600 Volts Inter. Trip 450 AC345HJK6G 600 Volts Inter. Trip 450 AC445HJK6G
600 Volts Inter. Trip 500 AC350HJK6G 600 Volts Inter. Trip 500 AC450HJK6G
600 Volts Inter. Trip 600 AC360HJK6G 600 Volts Inter. Trip 600 AC460HJK6G
Hi-Break Frames Three-Phase, Three-Wire THKM8 Hi-Break Frames Three-Phase, Four-Wire THKM8
ETE ETE
Voltage Trip Amps Product Number Voltage Trip Amps Product Number
L L
600 Volts Inter. Trip 300 AC330HKMG 600 Volts Inter. Trip 300 AC430HKMG
600 Volts Inter. Trip
600 Volts Inter. Trip
S O 400
500
AC340HKMG
AC350HKMG
600 Volts Inter. Trip
600 Volts Inter. Trip
S O400
500
AC440HKMG
AC450HKMG
OB OB
600 Volts Inter. Trip 600 AC360HKMG 600 Volts Inter. Trip 600 AC460HKMG
600 Volts Inter. Trip 700 AC370HKMG 600 Volts Inter. Trip 700 AC470HKMG
600 Volts Inter. Trip 800 AC380HKMG 600 Volts Inter. Trip 800 AC480HKMG
High Interrupting Spectra RMS Circuit Breaker High Interrupting Spectra RMS Circuit Breaker
Three-Phase, Three-Wire SELA Three-Phase, Four-Wire SELA
Short Circuit Short Circuit Short Circuit Short Circuit Short Circuit Short Circuit
Rating @ 240V Rating @ 480V Rating @ 600V Trip Product Rating @ 240V Rating @ 480V Rating @ 600V Trip Product
(kAIC) (kAIC) (kAIC) Amps Number (kAIC) (kAIC) (kAIC) Amps Number
100 65 25 15 AC31SELG 100 65 25 15 AC41SELG
100 65 25 20 AC32SELG 100 65 25 20 AC42SELG
100 65 25 30 AC33SELG 100 65 25 30 AC43SELG
100 65 25 40 AC34SELG 100 65 25 40 AC44SELG
100 65 25 50 AC35SELG 100 65 25 50 AC45SELG
100 65 25 60 AC36SELG 100 65 25 60 AC46SELG
100 65 25 70 AC37SELG 100 65 25 70 AC47SELG
100 65 25 80 AC38SELG 100 65 25 80 AC48SELG
100 65 25 90 AC39SELG 100 65 25 90 AC49SELG
100 65 25 100 AC310SELG 100 65 25 100 AC410SELG
100 65 25 110 AC311SELG 100 65 25 110 AC411SELG
100 65 25 125 AC312SELG 100 65 25 125 AC412SELG
100 65 25 150 AC315SELG 100 65 25 150 AC415SELG
High Interrupting Spectra RMS Circuit Breaker High Interrupting Spectra RMS Circuit Breaker
Three-Phase, Three-Wire SFLA Three-Phase, Four-Wire SFLA
Short Circuit Short Circuit Short Circuit Short Circuit Short Circuit Short Circuit
Rating @ 240V Rating @ 480V Rating @ 600V Trip Product Rating @ 240V Rating @ 480V Rating @ 600V Trip Product
(kAIC) (kAIC) (kAIC) Amps Number (kAIC) (kAIC) (kAIC) Amps Number
100 65 25 70 AC37SFLG 100 65 25 70 AC47SFLG
100 65 25 90 AC39SFLG 100 65 25 90 AC49SFLG
100 65 25 100 AC310SFLG 100 65 25 100 AC410SFLG
100 65 25 110 AC311SFLG 100 65 25 110 AC411SFLG
100 65 25 125 AC312SFLG 100 65 25 125 AC412SFLG
100 65 25 150 AC315SFLG 100 65 25 150 AC415SFLG
100 65 25 175 AC317SFLG 100 65 25 175 AC417SFLG
100 65 25 200 AC320SFLG 100 65 25 200 AC420SFLG
100 65 25 225 AC322SFLG 100 65 25 225 AC422SFLG
100 65 25 250 AC325SFLG 100 65 25 250 AC425SFLG
E Product Number
Tri-Break Three-Phase, Four-Wire TB6
Voltage
E T
Trip Amps E Product Number
600 Volts Fixed Trip 15
OL
300 AC430B6J14G
OBS
600 Volts Fixed Trip 20 AC32B1E05G 600 Volts Inter. Trip 400 AC440B6J14G
OBS
600 Volts Fixed Trip 30 AC33B1E05G 600 Volts Inter. Trip 500 AC450B6J14G
600 Volts Fixed Trip 40 AC34B1E05G 600 Volts Inter. Trip 600 AC460B6J14G
600 Volts Fixed Trip 50 AC35B1E09G
600 Volts Fixed Trip 70 AC37B1E09G
600 Volts Fixed Trip 100 AC310B1E09G
Tri-Break Three-Phase, Four-Wire TB8
E T E
OL
Voltage Trip Amps Product Number
OBS
Tri-Break Three-Phase, Three-Wire TB4 600 Volts Inter. Trip 600 AC460B8K22G
E T E
Product Number
600 Volts Inter. Trip
600 Volts Inter. Trip
700
800
AC470B8K22G
AC480B8K22G
600 Volts Inter. Trip
600 Volts Inter. Trip
S O
125
150
L AC312B4F14G
AC315B4F14G
B
600 Volts Inter. Trip 200 AC320B4F14G
Switch-Operated Fusible Plugs Three-Phase, Three-Wire
O
600 Volts Inter. Trip 225 AC322B4F14G
600 Volts Inter. Trip 300 AC330B4F14G Voltage Trip Amps Product Number
600 Volts Inter. Trip 400 AC340B4F14G
240 30 AC321RG
240 60 AC322RG
240 100 AC323RG
Tri-Break Three-Phase, Three-Wire TB6
E
240 200 AC324RG
L E TProduct Number
240
240
400
600
AC325RG
AC326RG
O
600 Volts Inter. Trip 300 AC330B6J14G 480 or 600 30 AC361RG
600 Volts Inter. Trip
600 Volts Inter. Trip
600 Volts Inter. Trip
O B S 400
500
600
AC340B6J14G
AC350B6J14G
AC360B6J14G
480 or 600
480 or 600
480 or 600
480 or 600
60
100
200
400
AC362RG
AC363RG
AC364RG
AC365RG
480 or 600 600 AC366RG
ETE
Tri-Break Three-Phase, Three-Wire TB8 With QMR Interrupter Fuses Not Included
SOL
Voltage Trip Amps Product Number
600 Volts Inter. Trip 600 AC360B8K22G
Switch-Operated Fusible Plugs Three-Phase, Four-Wire
OB
600 Volts Inter. Trip 700 AC370B8K22G
600 Volts Inter. Trip 800 AC380B8K22G Voltage Trip Amps Product Number
240 30 AC421RG
240 60 AC422RG
Tri-Break Three-Phase, Four-Wire TB1 240 100 AC423RG
240 200 AC424RG
Voltage
600 Volts Fixed Trip
Trip Amps
15
E T E Product Number
AC41B1E05G
240
240
400
600
AC425RG
AC426RG
OL
600 Volts Fixed Trip 20 AC42B1E05G 480 or 600 30 AC461RG
OBS
600 Volts Fixed Trip 30 AC43B1E05G 480 or 600 60 AC462RG
600 Volts Fixed Trip 40 AC44B1E05G 480 or 600 100 AC463RG
600 Volts Fixed Trip 50 AC45B1E09G 480 or 600 200 AC464RG
600 Volts Fixed Trip 70 AC47B1E09G 480 or 600 400 AC465RG
600 Volts Fixed Trip 100 AC410B1E09G 480 or 600 600 AC466RG
ETE
Voltage Trip Amps Product Number
600 Volts Inter. Trip
600 Volts Inter. Trip
600 Volts Inter. Trip
S O L
125
150
200
AC412B4F14G
AC415B4F14G
AC420B4F14G
OB
600 Volts Inter. Trip 225 AC422B4F14G
600 Volts Inter. Trip 300 AC430B4F14G
600 Volts Inter. Trip 400 AC440B4F14G
OL
Voltage Trip Amps Product Number Ampere Rating Type
E 100 max. AC3100EG1 30 Electrically Held
F
O B S 225 AC3225FG1
1Not for Spectra breakers. E and F frame enclosures for standard molded case
circuit breakers only.
60
100
30
60
Electrically Held
Electrically Held
Mechanically Held
Mechanically Held
(Order circuit breaker from Section 6.) 100 Mechanically Held
30 Pilot Light
60 Pilot Light
E
100 Pilot Light
Enclosure Only Three-Phase, Four-Wire Ground Standard
Voltage Trip Amps
E T Product Number
30
60
Pushbutton or Selector Switch
Pushbutton or Selector Switch
OL
100 Pushbutton or Selector Switch
E 100 max. AC4100EG1
OBS
30 Control Transformer2
F 225 AC4225FG1
60 Control Transformer2
1Not for Spectra breakers. E and F frame enclosures for standard molded case 100 Control Transformer2
circuit breakers only. 30 Extra Interlock
(Order circuit breaker from Section 6.) 60 Extra Interlock
100 Extra Interlock
30 Two-wire Control
OL
Voltage Product Number 30 Auxiliary Contact
60 Auxiliary Contact
OBS
208-240 AC321N 100 Auxiliary Contact
440-600 AC361N
2Includes one secondary fuse.
Not UL Listed
Types FVA and FVK Busway Aluminum Bus for Type FVA 800 Amps Three-Phase,
Types FVA and FVK Flex-A-Power
busway are obsolete for new Three-Wire, or Three-Wire, DC 600 Volts
manufacture. Only end boxes and cable tap boxes are available. Component Type Product Number
Accessories End Box DASKEB310
Accessories Cable Tap Box DAACB381
Aluminum Bus for Type FVA 225 Amps Three-Phase, 1Center cable tap box. For end cable tap box, order this tap box plus an end box.
Aluminum Bus for Type FVA 600 Amps Three-Phase, Copper Bus for Type FVK 600 Amps Three-Phase,
Four-Wire 480 Y/277 or 208 Y/120 Volts, Half Capacity Neutral Three-Wire, or Three-Wire, DC 600 Volts
Component Type Product Number Component Type Product Number
Accessories End Box DASKEBN1310A Accessories End Box DASKEB36
Accessories Cable Tap Box DAACBN1361 Accessories Cable Tap Box DAKCB361
1Center cable tap box. For end cable tap box, order this tap box plus an end box. 1Center cable tap box. For end cable tap box, order this tap box plus an end box.
Aluminum Bus for Type FVA 800 Amps Three-Phase, Copper Bus for Type FVK 800 Amps Three-Phase,
Four-Wire 480 Y/277 or 208 Y/120 Volts, Half Capacity Neutral Three-Wire, or Three-Wire, DC 600 Volts
Component Type Product Number Component Type Product Number
Accessories End Box DASKEBN1310A Accessories End Box DASKEB310
Accessories Cable Tap Box DAACBN1381 Accessories Cable Tap Box DAKCB3101
1Center cable tap box. For end cable tap box, order this tap box plus an end box. 1Center cable tap box. For end cable tap box, order this tap box plus an end box.
Copper Bus for Type FVK 225 Amps Three-Phase, Copper Bus for Type FVK 1000 Amps Three-Phase,
Three-Wire, or Three-Wire, DC 600 Volts Three-Wire, or Three-Wire, DC 600 Volts
Component Type Product Number Component Type Product Number
Accessories End Box DASKEB34 Accessories End Box DASKEB310
Accessories Cable Tap Box DAKCB321 Accessories Cable Tap Box DAKCB3101
1Center cable tap box. For end cable tap box, order this tap box plus an end box. 1Center cable tap box. For end cable tap box, price and order this tap box plus an
end box.
Copper Bus for Type FVK 225 Amps Three-Phase, Copper Bus for Type FVK 1000 Amps Three-Phase,
Four-Wire 480 Y/277 or 208 Y/120 Volts, Half Capacity Neutral Four-Wire 480 Y/277 or 208 Y/120 Volts, Half Capacity Neutral
Component Type Product Number Component Type Product Number
Accessories End Box DASKEBN134A Accessories End Box DASKEBN1310A
Accessories Cable Tap Box DAKCBN132A1 Accessories Cable Tap Box DAKCBN1310A1
1Center cable tap box. For end cable tap box, order this tap box plus an end box. 1Center cable tap box. For end cable tap box, order this tap box plus an end box.
Copper Bus for Type FVK 400 AmpsThree-Phase, Fusible PlugsType QMR Three-Phase, Three-Wire
Four-Wire 480 Y/277 or 208 Y/120 Volts, Half Capacity Neutral Component Voltage Product Number
Externally Operated with Class H Fuse Clips. Fuses Not Included. To add Class R or
Class J fuse provisions, see page 13-93.
3Special hanger required on LVDP. Furnish nameplate data and see extension pan
table. See page 13-93.
4T suffix on product number indicates 2(200A) switches used to make up a 400A
requirement.
(Not UL listed)
Circuit Breakers - Standard Frames Three-Phase, Circuit Breakers - Standard Frames Three-Phase,
Three-Wire TEB Three-Wire TK4V
Voltage Trip Amps Product Number Voltage Trip Amps Product Number
240 Volts Fixed Trip 15 FVK31EB 600 Volts 300 FVK330KM
240 Volts Fixed Trip 20 FVK32EB 600 Volts 400 FVK340KM
240 Volts Fixed Trip 30 FVK33EB 600 Volts 500 FVK350KM
240 Volts Fixed Trip 40 FVK34EB 600 Volts 600 FVK360KM
240 Volts Fixed Trip 50 FVK35EB 600 Volts 700 FVK370KM
240 Volts Fixed Trip 70 FVK37EB 600 Volts 800 FVK380KM
240 Volts Fixed Trip 100 FVK310EB
Hanger Dimensions
With Aluminum Bus Bars
Housing Hanger Hanger Hanger
Amperage Depth (in.) Dimension A (in.) Dimension B (in.) Dimension C (in.)
225 Amps 3.19 4.69 1.88 2.5
400 Amps 4.19 5.19 1.88 2.56
600 Amps 6.19 6.19 1.63 3.81
800 Amps 6.19 6.19 1.63 3.81
Features
Model ZTX switches are built for residential and light commercial
applications requiring the dependability and ease of operation
found in a power contactor switch.
Model ZTX switches are equipped with the MX60 control panel as
standard. This microprocessor control includes:
Ordering Information
Z T X 0 0 0 0 Z E C Z V C M 0 6 0
Model/Type Control Application Ampere Switched Enclosure Type Operational Voltage Accessories
Panel Size Poles
Z T X 0 0 0 M 6 0 0 0 4 B 0 1 A B A3/A4
Standard (Open Transition) MX60 Micro- Utility- 40 amps 2 Poles Type 1 Enclosed Consult Table Below Auxiliary Contacts (1 each)
processor Generator Closed in Source 1 (normal)
Control Unit and Source 2 (emergency)
0 0 8 E 3 R
0 0 80 amps 3 Poles Type 3R Enclosure
B9X
No Microprocessor Battery Charger
Control Unit 1.5 Amp/12 or 24 VDC
0 1 0 F 0 0
100 amps 4 Poles Open Style For information on
Unit
ZTX OEM plans,
0 1 5 please consult your
GE representative
150 amps
Dimensions
Ampere NEMA 1 NEMA 3R
Poles
Rating Height Width Depth Height Width Depth
40-225 2, 3, 4 24 18 10 24 18.5 10.5
300-400 2, 3, 4 46 24 14 46 24 15
Features
Model ZTG switches are built for standard applications requiring
the dependability and ease of operation found in a power
contactor switch.
Options
6A Test Switch, Maintained UMD Universal Motor Load Disconnect Circuit: Auxiliary Con-
6AP Test Switch, Maintained Programmable tact opens 0-5 minutes prior to transfer in either direc-
A1 Auxiliary Contact, operates on Source 1 line failure tion, re-closes after transfer. Can be configured by end
A1E Auxiliary Contact, operates on Source 2 line failure user for Pre-transfer, Post-transfer, or both.
A3 Auxiliary Contacts: Closed when the transfer switch is in VI Voltage Imbalance Monitor (Three Phase)
Source 2 position NOTE: For applications requiring additional options or other configurations, use
A4 Auxiliary Contacts: Closed when the transfer switch is in GE Zenith Factory.
Source 1 position
A62 Sequential Universal Motor Load Disconnect Circuit.
Normally closed Auxiliary contacts for Motor Loads.
Open 0-60 seconds pior to transfer, after transfer, or
both in either direction then reclose in timed sequence
after transfer.
ATGEW-X Extended annual parts and labor warranty (1-4 years for
a total of 5 years max.)
CTAP Alarm panel on transfer to emergency w/silence button
& light
DS Inhibits transfer in either direction when in inhibit. Allows
automatic operation when in Auto (Standard on 800A
and above)
HT Heater and Thermostat
LCM LonWorks Communication Module
MCM Modbus RTU Communication Module
Testing Standards
UL, CSA and IEC listed UL 1008, CSA 22.2 No. 178, IEC 947-6-1
Ringing wave immunity IEEE 472 (ANSI C37.90A)
Conducted and Radiated Emissions EN55022 Class B (CISPR 22) (Exceeds EN55011 & MILSTD 461 Class 3)
ESD immunity test EN61000-4-2 Class B (Level 4)
Radiated RF, electromagnetic field immunity test EN61000-4-3 (ENV50140) 10v/m
Electrical fast, transient/burst immunity test EN61000-4-4
Surge immunity test EN61000-4-5 IEEE C62.41 1.2 X 50s, 0.5 & 4 kV
Conducted immunity test EN61000-4-6 (ENV50141)
Voltage dips and interruption immunity EN61000-4-11
ZTG AL/CU UL Listed Solderless Screw-Type Terminals for External Power Connections1
Normal, Emergency and Load Terminals
Switch Size (Amps) Cables per Phase & Neutral Range of Wire Sizes
40
1 #8 to 3/0 8-85 mm2
80
100
150 1 #6 to 250 MCM 13-127 mm2
200, 225
260 #6 to 350 MCM 13-177 mm2
1
400 #4 to 600 MCM 21-304 mm2
600 2
#2 to 600 MCM 33-304 mm2
800, 1000, 1200 4
1600, 2000, 2600, 3000 8 #2 to 600 MCM 33-304 mm2
1 For ZTGD Series data, contact the GE Zenith factory
Ordering Information
Z A 0 Z E C Z V C
Model/Type Control Application Ampere Switched Enclosure Type Operational Voltage Accessories
Panel Size Poles
Z T G 0 0 0 A 0 0 0 0 4 B 0 1 A B M S T D
Standard (Open Transition) Entelli-Switch Utility- 40 amps 2 Poles Type 1 Enclosed Consult Table Below
150 Micro- Generator M E X E
processor
Control Unit
U 0 0 8 E 1 2
Z T G D 0 0 Utility- 80 amps 3 Poles Type 12 Enclosure M A N O
Utility Then choose
Delayed Transition
M 0 1 0 F 3 R additional accessories
Application Notes:
1. Metric dimensions (cm) and weights (kg) shown in parentheses adjacent to English measurements.
2. Includes 1.25" door projection beyond base depth. Allow a minimum of 3" additional depth for projection of handle, lights, switches, pushbuttons, etc.
3. All dimensions and weights are approximate and subject to change without notice.
4. Packing materials must be added to weights shown. Allow 15% additional weight for cartons, skids, crates, etc.
5. Special enclosure (NEMA 3R, 4, 4X, 12, etc.) dimensions and layouts may differ. Consult the GE Zenith factory for details.
6. A ZTG(D) 40-225A, when ordered with the following options, will require a larger enclosure: A62(T), Digital Meter, HT, OCVR-1SG, OCVR-1SS.
Contact the GE Zenith factory for dimensions.
7. Add 3" in height for removable lifting eyes.
8. Ventilation louvers on side and rear of enclosure at 1600-3000 amps. One set of louvers must be clear for airflow with standard cable connections.
Reference Figures
Features
While providing the functionality of an automatic transfer switch
the ZTGSE integrates the utility circuit breaker, optional surge
protection device and power monitor into one simple
coordinated package.
Reference Charts
Testing Standards
UL, CSA UL 1008, UL891, CSA 22.2
Ringing wave immunity IEEE 472 (ANSI C37.90A)
Conducted and Radiated Emissions EN55022 Class B (CISPR 11) (Exceeds EN55011 & MILSTD 461 Class 3)
ESD immunity test EN61000-4-2 (Level 4)
Radiated RF, electromagnetic field immunity test EN61000-4-3 (ENV50140) 10v/m
Electrical fast, transient/burst immunity test EN61000-4-4
Surge immunity test EN61000-4-5 IEEE C62.41 1.2 X 50s, 5 & 8 kV
Conducted immunity test EN61000-4-6 (ENV50141)
Voltage dips and interruption immunity EN61000-4-11
Ordering Information
Z T G S E 0 A 0 0 N 0 1 M S T D G
Base Model Type Control Config. Ampere Size Switched Enclosure Operational Accessories
Panel Poles Type Voltage
S E 0 A 0 0 0 0 4 B N 0 1 A B M S T D G
Standard MX150 Utility - 40 amps 2 Poles Type 1 Enclosure Consult Table
(Open Transition Microprocessor Generator Below M E X E G
Transfer Switch) Control Unit 0 0 8 E N 3 R
80 amps 3 Poles Type 3R Enclosure
D S E If Required, choose
additional accessories.
Standard 0 1 0 F
(Delayed 100 amps 4 Poles
Transition
Transfer Switch)
0 1 5
150 amps
Dimensional Specifications
ZTGSE and ZTGDSE Model Transfer Switches
NEMA 1 Enclosure NEMA 3R Enclosure
Model Ampere Rating Poles H W D Ref. Fig. H W D Ref. Fig. App. Notes
40-80 2, 3, 4 51(130) 28(71) 16(41) A 51(130) 29(74) 20(51) A 1-5
100-200 2, 3, 4 51(130) 28(71) 16(41) A 51(130) 29(74) 20(51) A 1-5
225 2, 3, 4 51(130) 28(71) 16(41) A 51(130) 29(74) 20(51) A 1-5
ZTGSE/ 260 2, 3, 4 51(130) 28(71) 16(41) A 51(130) 29(74) 20(51) A 1-5
ZTGDSE 400 2, 3, 4 51(130) 28(71) 16(41) A 51(130) 29(74) 20(51) A 1-5
600 2, 3, 4 73(185) 34(86) 20(51) B 73(185) 34(86) 24(61) B 1-6
2, 3 73(185) 34(86) 20(51) B 73(185) 34(86) 24(61) B 1-6
800
4 73(185) 40(102) 20(51) B 73(185) 40(102) 24(61) B 1-6
Application Notes:
1. Metric dimensions (cm) and weights (kg) shown in parentheses adjacent to English measurements.
2. Includes 1.25" door projection beyond base depth. Allow a minimum of 3" additional depth for projection of handle, lights, switches, pushbuttons, etc.
3. All dimensions and weights are approximate and subject to change without notice.
4. Packing materials must be added to weights shown. Allow 15% additional weight for cartons, skids, crates, etc.
5. Add 4 inches in depth for NEMA 3R enclosure.
6. Add 3 in height for lifting eyes.
7. Contact factory for dimensional and weight information for 1000 Amps and above.
Weights
Model Amp Rtg Poles NEMA 1 Weight NEMA 3R Weight
2 157(71) 212(96)
40-80 3 159(72) 214(97)
4 163(74) 218(99)
2 162(74) 217(99)
100-200 3 164(75) 219(99)
4 168(76) 223(101)
2 169(77) 224(102)
225 3 171(78) 226(103)
4 175(79) 230(104)
2 178(81) 233(106)
ZTGSE 260 3 183(83) 238(108)
4 187(85) 242(110)
2 254(115) 309(140)
400 3 265(120) 320(145)
4 289(131) 344(156)
2 467(212) 552(250)
600 3 483(219) 568(257)
4 512(232) 597(271)
2 567(257) 652(296)
800 3 577(262) 662(300)
4 662(300) 767(348)
2 262(119) 317(144)
40-400 3 273(124) 328(149)
4 296(134) 351(159)
2 475(215) 560(254)
ZTGDSE 600 3 491(222) 576(261)
4 520(236) 605(274)
2 570(259) 655(297)
800 3 580(263) 665(302)
4 665(302) 770(349)
Reference Figures
D W
D W
H H
Figure A Figure B
ZTGSE Series Transfer Switch (40-400 Amp) ZTGSE Series Transfer Switch (600-800 Amp)
Since its introduction, the GE Zenith ZTS Series of transfer All ZTS products meet or exceed industry requirements allowing
switches has become a hallmark of quality and performance. specification and installation confidence.
Reliability resulting from superior design and heavy duty construction UL 1008 listed through 480 VAC
has made the ZTS the industry standard for critical installations. CSA C22.2 No. 178 listed through 600 VAC
Our emphasis on research and development, design IEC 947-6-1 listed through 480 VAC
improvements, materials, manufacturing methods, quality Codes and Standards
assurance, and service yields products that have been proven in NFPA 70, 99, 101, 110
hundreds of thousands of applications. IEEE 446, 241
NEC 517, 700, 701, 702
Our engineering staff has been dedicated to the improvement and NEMA ICS2-447
expansion of our line. Today, GE Zenith offers the widest selection of Controls tested in accordance with:
transfer switch products worldwide. IEEE 472 (ANSI C37.90A)
ZTS Automatic Transfer Switches EN55022 Class B (CISPR 22) (Exceeds EN55011
40-4000 Amps & MILSTD 461 Class 3)
ZTSD Delayed Transition Transfer Switches EN61000-4-2 (Level 4)
40-4000 Amps EN61000-4-3 (ENV50140) 10 v/m
ZTSCT Closed Transition Transfer Switches EN61000-4-4
100-4000 Amps EN61000-4-5, IEEE C62.41 (1.2 X 50s, 0.5 & 4 kV)
ZBTS Automatic Transfer/Bypass Switches EN61000-4-6 (ENV50141)
100-4000 Amps EN61000-4-11
ZBTSD Delayed Transition Bypass Switches Enclosures meet the requirements of:
100-4000 Amps UL 508, 50
ZBTSCT Closed Transition Bypass Switches ANSI C33.76
100-4000 Amps ICS 6
ZTSMV Medium Voltage Switches NEMA 250
600-3000 Amps Quality System:
ISO 9001 Registered
Equipment (controls and power section) seismic tested to:
IBC2009
IEEE6932003
User-Friendly Operation
LEDs are used in a recognizable line configuration for continuous
monitoring of switch position. A new LCD display shows source
availability, exercise time delay operation and system source
condition. A new simplified adjustment is featured for voltage,
frequency and time delay settings.
Z B 0 Z E C Z V C
Model/Type Control Application Ampere Size Switched Enclosure Type Operational Voltage Accessories
Panel Poles
Z T S 0 0 0 B 0 0 0 0 4 B 0 1 A B M S T D
Standard (Open Transition) Entelli-Switch 250 Utility - Generator 40 amps 2 Poles Type 1 Enclosed Consult Table Below
Microprocessor
Control Unit M E X E
Z T S D 0 0 U 0 0 8 E 1 2
Delayed Transition Utility - Utility 80 amps 3 Poles Type 12 Enclosure
M C O N
Z T S C T 0 M 0 1 0 F 3 R
Closed Transition 100 amps Type 3R Enclosure
M S E N
Manual 4 Poles
Z B T S 0 0 G 0 1 5 4 0 M S P E
Standard (Open Transition) w/Bypass Gen to Gen 150 amps Type 4 Enclosure
M P S G
Z B T S D 0 0 2 2 4 X
Delayed Transition w/Bypass 225 amps Type 4X Enclosure M A N 0
Z B T S C T 0 2 6 0 0
Closed Transition w/Bypass Then choose
260 amps
Open Style Unit additional accessories
0 4 0
Switch Types 400 amps
A B Voltage Phase ConWg. Hz
Standard: Unless otherwise noted, the 1 0 120 1 2 wire 60
standard switch with quick transfer will 0 6 0 2 0 120/240 1 3 wire 60
600 amps 2 1 120/208 1 3 wire 60
be supplied. 3 0 240 3 3 wire 60
Delayed Transition: When ordered as the 0 8 0 3 1 208 3 3 wire 60
ZTSD, the delayed transition switch offers 800 amps 3 2 220 3 3 wire 50
3 3 120/240 3 4 wire 50
time delay during transfer from one position 1 0 0 3 4 110/220 3 4 wire 60
to the other. This is primarily for transfer of 1000 amps
3 5 139/240 3 4 wire 60
3 8 120/240 3 4 wire 60
large motor or inductive loads.
4 0 120/208 3 4 wire 60
Closed Transition: When ordered as the 1 2 0 4 1 127/220 3 4 wire 60
1200 amps
ZTSCT, the closed transition switch offers 4 2 127/220 3 4 wire 50
5 0 480 3 3 wire 60
two basic modes of operation. During a 1 6 0 5 1 440 3 3 wire 60
failure of one source or an out of specifica- 1600 amps 5 2 440 3 3 wire 50
tion condition, the ZTSCT Model operates 5 5 460 1 3 wire 50
2 0 0 5 7 480 1 2 wire 60
as a standard delayed transition switch 5 8 254/440 3 4 wire 60
2000 amps
(ZTSD Model). This sequence allows clear 6 0 575 3 3 wire 60
3 0 0 6 1 347/600 3 4 wire 60
separation of an unreliable source from an
7 0 277/480 3 4 wire 60
available one. 3000 amps
7 1 277 1 2 wire 60
Bypass: When ordered as the ZBTS, the 4 0 0
7 4 266/460 3 4 wire 60
7 5 460 3 3 wire 60
bypass transition switch offers a draw-out 4000 amps 8 0 120/240 2 4/5 wire 60
mechanism, with electrical and mechanical 8 2 380 1 2 wire 50
interlocks for secure removal after load by- 9 0 240/416 3 4 wire 60
9 1 220/380 3 4 wire 60
pass. In this way the transfer switch and/or 9 2 220/380 3 4 wire 50
the control panel may be tested, isolated 9 3 240/416 3 4 wire 50
9 7 380 3 3 wire 60
and removed for maintenance without
load interruption. Note: Operating voltage must be specified at time of order.
Only the most common voltages are shown above.
Product # Example
ZTSCT0B00040F-ZEC01ZVC40MSTD
This number string shows the correct format for a ZTS Model Auto-
matic Transfer Switch with closed transition, an Entelli-Switch 250
microprocessor control unit, Utility - Generator, 400 amps, 4 pole,
NEMA Type 1 enclosure, 120/208V 3F, 4 wire, 60 Hz system with
the standard group of accessories.
UL 1008 Withstand and Closing Ratings
Please refer to GE Zenith Controls Bulletin TB-1102.
Application Notes: C B
C B
1. Metric dimensions (cm) and weights (Kg) shown in parenthesis
adjacent to English measurements in inches and pounds.
2. Includes 1.25" door projection beyond base depth. Allow a mini-
mum of 3" additional depth for projection of handle, light,
switches, pushbuttons, etc. A
A
3. All dimensions and weights are approximate and subject to
change without notice.
4. Special enclosures (NEMA 3R, 4, 12, etc.) dimensions and
layout may differ. Consult the GE Zenith factory for details.
5. Normal and emergency may be ordered inverted on any switch. Figure A Figure B
The load may be inverted 600-1200 amps. Consult the GE Zenith
factory for details. C B
6. Special lug arrangements may require different enclosure dimen-
sions. For certified drawings, contact the GE Zenith factory.
7. Packing materials must be added to weights shown. Allow 15%
additional weight for cartons, skids, crates, etc.
8. Add 4" in height for removable lifting lugs. A
9. Lug adapters for 3000-4000 amp limits may be staggered length
for ease of entrance. Consult the ge Zenith factory for details.
10. Ventilation louvers on both sides and rear of enclosure. Louvers
must be clear for airflow with standard cable connections.
11. A ZTS 40-150A, when ordered with the following options, will re-
quire a larger enclosure of 46" x 24" x 14" (HxWxD): A62(T), Digital Figure C
Meter, HT, HH, K, LDS, L11, N1, N2, OCVR-1SG, OCVR-1SS, P2,
Q2M, Q3M, Q7M, R26(D). AL-CU UL Listed Solderless Screw-Type Terminals
12. For Delayed and Closed Transition dimensions and weights, refer for External Power Connections
to GE Zenith Publication PB-5067 and PB-5069. Normal, & Load Terminals
Switch Size Amps Cables/Pole Wire Ranges
13. For Bypass/Isolation dimensions and weights, refer to GE Zenith
40-80 1 #8 to 3/0
Publication pb-5068. 100, 150 1 #6 to 250 MCM
14. A ZTS, when ordered with compression lugs suitable for use with 225 1 #4 to 600 MCM
copper cables, will require a larger enclosure. For 40-225A, the 260 1 #4 to 600 MCM
400 1 #4 to 600 MCM
enclosure is 46" x 24" x 14" (HxWxD). For 260-400A, the enclosure 600 2 #2 to 600 MCM
is 66" x 24" x 19.75". For 600A, the enclosure is 74" x 40" x 19.75". 800, 1000, 1200 4 #2 to 600 MCM
For certified drawings, please contact the GE Zenith factory. 1600, 2000,3000, 4000 *
Notes
* Line and load terminals are located in rear and arranged for bus bar connection. Terminal lugs are available as an accessory. Contact GE Zenith factory for more details.
1. Special terminal lugs and neutral bars are available at additional cost. Contact factory and advise cable sizes and number of conductors per pole.
2. Fully rated neutral provided on 3 phase, 4 wire system.
3. Special lug arrangements may require different enclosure dimensions. For certified drawings, contact the GE Zenith factory.
Application Notes:
1. Metric dimensions (cm) and weights (Kg) shown in parenthesis adjacent to English measurements in inches and pounds.
2. Includes 1.25" door projection beyond base depth. Allow a minimum of 3" additional depth for projection of handle, light, switches, pushbuttons, etc.
3. All dimensions and weights are approximate and subject to change without notice.
4. Special enclosures (NEMA 3R, 4, 4X, 12, etc.) dimensions and layout may differ. Consult the GE Zenith factory for details.
5. Normal and emergency may be ordered inverted on any switch. The load may be inverted 600-1200 amps. Consult the factory for details.
6. Special lug arrangements may require different enclosure dimensions. For certified drawings, contact the GE Zenith factory.
7. Packing materials must be added to weights shown. Allow 15% additional weight for cartons, skids, crates, etc.
8. Add 4" in height for removable lifting lugs.
9. Lug adapters for 3000-4000 amp limits may be staggered length for ease of entrance. Consult the GE Zenith factory for details.
10. Ventilation louvers on both sides and rear of enclosure. Louvers must be clear for airflow with standard cable connections.
11. A ZTS 40-150A, when ordered with the following options, will require a larger enclosure of 46x 24x 14 (HxWxD): A62(T), Digital Meter HT, HH, K, LDS, L11, N1, N2, OCVR-
1SG, OCVR-1SS, P2, Q2M, Q3M, Q7M, R26(D).
12. For Delayed and Closed Transition dimensions and weights, refer to GE Zenith publication PB-5067 and PB-5069.
13. For Bypass/Isolation dimensions and weights, refer to GE Zenith publication PB-5068.
14. A ZTS, when ordered with compression lugs suitable for use with copper cables will require a larger enclosure. For 40-225A, the enclosure is 46 x 24 x 14 (H x W x D). For
260-400A, the enclosure is 66 x 24 x 19.75. For 600A, the enclosure is 74 x 40 x 19.75. For certified drawings, please contact the GE Zenith factory.
Application Notes:
1 - 9, 11, 13. Same as above
10. Ventilation louvers on both sides and rear of enclosure. One set of louvers must be clear for airflow with standard cable connectors.
Reference Figures
Application Notes:
1. Metric dimensions (cm) and weights (Kg) shown in parenthesis adjacent to English measurements in inches and pounds.
2. Includes 1.25" door projection beyond base depth. Allow a minimum of 3" additional depth for projection of handle, light, switches, pushbuttons, etc.
3. All dimensions and weights are approximate and subject to change without notice.
4. Special enclosures (NEMA 3R, 4, 4X, 12, etc.) dimensions and layout may differ. Consult the GE Zenith factory for details.
5. Bypass Model product can not be ordered with inverted style.
6. Special lug arrangements may require different enclosure dimensions. For certified drawings, contact the GE Zenith factory.
7. Packing materials must be added to weights shown. Allow 15% additional weight for cartons, skids, crates, etc.
8. Add 4" in height for removable lifting lugs.
9. ZBTS(D) 600-1200A and ZBTSCT 100-1200A standard configuration is top entry. 14 rear adapter bay required for bottom entry. Consult GE Zenith
factory for details.
10. Bypass switch weights for 1600 - 4000 amp units vary up to 10% based on connections variations. Weights shown are for estimation only.
11. 3000 amp depth dimension shown is standard. Depending on your cable/conduit requirements you may desire a deeper enclosure. Consult the
GE Zenith factory for further details.
12. Lug adapters for 3000-4000 amp limits may be staggered length for ease of entrance. Consult the GE Zenith factory for details.
Reference Figures
C B
14" C B C B
Vent
See
A Note A
9 A
Vent
Application Notes:
1. Metric dimensions (cm) and weights (Kg) shown in parenthesis adjacent to English measurements in inches and pounds.
2. Includes 1.25" door projection beyond base depth. Allow a minimum of 3" additional depth for projection of handle, light, switches, pushbuttons, etc.
3. All dimensions and weights are approximate and subject to change without notice.
4. Special enclosures (NEMA 3R, 4, 4X, 12, etc.) dimensions and layout may differ. Consult the GE Zenith factory for details.
5. Normal and emergency may be ordered inverted on any switch. The load may be inverted 6001200 amps. Consult the factory for details.
6. Special lug arrangements may require different enclosure dimensions. For certified drawings, contact the GE Zenith factory.
7. Packing materials must be added to weights shown. Allow 15% additional weight for cartons, skids, crates, etc.
8. Add 4" in height for removable lifting lugs.
9. 4000 amp depth dimension shown is standard. Depending on your cable/conduit requirements you may desire a deeper enclosure. Consult the
GE Zenith factory for further details.
10. Lug adapters for 3000-4000 amp limits may be staggered length for ease of entrance. Consult the GE Zenith factory for details.
Reference Figures
Figure A Figure B
Introduction
ZTS Series Automatic Transfer Switches have been the preferred
standard for quality and reliability in the electrical industry. The
ZTSMV Model medium voltage automatic transfer switches pro-
vides that same quality for installations from 5kV to 15kV.
The ZTSMV Model is designed for use in the most critical applica-
tions: hospitals, military sites, airports, communications facilities,
and computer installations. ZTSMV Model switches fit the need for
dependable continuity of power where emergency or standby ap-
plications exist.
Backed by over 75 years of experience in manufacturing auto-
matic transfer switches, as well as extensive experience in the de-
sign and development of paralleling switchgear systems, the GE
ZTSMV Model provides the reliable answer to critical medium volt-
age switching applications. Like all GE switches, the ZTSMV Model
is supported by a nationwide network of field service facilities.
Construction
The switching elements consist of two vacuum circuit breakers in-
terlocked to ensure that only one set of contacts can be closed at
any one time. The control module for transferring operations of
the power unit is the same reliable microprocessor control system ZTSMV
that GE has designed, built and used on our low voltage auto-
matic transfer switches. The control module is physically isolated
from the power portion by an insulating barrier. The completed
unit is enclosed in a NEMA1 cabinet (NEMA 3R optional) and is
both front and rear accessible.
ZTSMV
Rated Voltage 5kV 15kV 15kV
MVA Class 250 500 1,000
System Voltage 2.4 - 4.16 kV 7.2 - 13.8 kV 7.2 - 13.8 kV
Rated Current 1,200 A 1,200 - 3,000 A 1,200 - 3,000 A
Short Circuit Rating 29 kA @ 4.16 kV 20 kA @ 13.8 kV 40 kA @ 13.8 kV
33 kA @ 7.2 kV
NOTE: Additional ratings are available. Consult the factory for details.
Ordering Information
Z T S M V
Block A Block B Block C Block D Block E Block F Block G Block H Block I
ZTE Series
Low-Voltage, Open Transition, Automatic and Manual Transfer
Switches
Ideal for mixed (inductive and resistive) mission critical loads
Contact transfer speed less than 100 milliseconds
Double throw, interlocked operation
Ratings 40 to 4000 amperes Control Group Options (see order code)
Group A: All standard features, Field re-programmable I/O (4 in-
Ratings & Construction puts, 4 outputs), Control Switches (Test with Load, Test no load,
Ratings Voltage, Ampere and Pole configuration per Fast Test, Alarm Reset, Auto/Man Re-transfer Source 1,
Order Code Auto/Man Transfer both sources, Preferred Source select,
Certifications UL 1008, CSA C22.2 Commit/No Commit Transfer to Gen, Time Delay Bypass
Certifications Third-party Seismic Certification to IBC 2009, Group B: All features from A plus: 10 User-configurable Analog
3.2g @ Ip = 1.5 (operation during event) & 10 Digital Alarms, 20-channel data logger, 10-channel wave-
Electrical Operator Momentarily energized, high-speed form capture, Auto Load Shed (with voltage, frequency, and
solenoid mechanism kW triggers)
Mechanism Mechanically-held with mechanical interlock to Group C: All features from B plus: 4 additional field program-
inhibit connection of both sources to the load mable inputs (total 8 inputs, 8 outputs)
Contacts GE design and manufactured, silver tungsten alloy Group D: All features from C plus: 4 additional field program-
with separate arcing contacts on 600A and above ratings for mable inputs (total 12 inputs, 12 outputs) & GE Flexlogic user-
high withstand and close-on capability configurable control logic
Neutral Pole (4 pole only) Identical construction to phase Group M: Manual ATS configuration
poles with fully rated main and arcing contacts. Operation via
same mechanism as phase poles to prevent sustained connec- Additional Standard Features
tion of source neutrals in separately derived systems, as last- Engine Exerciser Configurable Periodic Exerciser (7 Event
break/first-make transfer. Daily, Weekly, 14 or 28 day) or Clock Exerciser Type (21 Event,
365 day Programmable)
Controller System Status Screen Active state of switch, display of all time
Construction Dual-processor based, with dedicated processor delays and alarm conditions
for high-speed Serial or Ethernet communications Event Recorder 256 Event, 1ms accuracy, clock sync via
Source Sensing Direct 120-690V sensing and software config- Network Time Protocol (NTP)
uration of rated voltage and frequency without the need for Outage & Test Report Screen Date/time stamping of: outage or
potential transformers, step-down transformers or DIP switches test event, start signal sent, Gen start time, connection to Gen,
Control Wiring All customer connections at one location. All Max Gen Volts & Freq dip, return of utility, re-transfer to normal
signals in/out relay-isolated via DIN-mounted relay/terminal External Power Supply Standard 120VAC input for controller
blocks. All control wiring via factory-installed wiring harnesses power and communication and 24 VDC input for remote control
Enclosure and annunciation when both sources de-energized
Flexible Feature Assignment Field reassignable I/O for any/all
Type per Order Code
control features
Display, Sensing & Time Delays In-Phase Monitor For phase matching prior to Live-Live
Display VGA color graphical with embedded HELP menus transfers of load
Annunciation High intensity LED for Source Availability (2), Optional Features (see order code)
Source Connected (2), Transfer Inhibit (not in Auto)
Serial Communications High speed, up to 115k Baud
Source Fail/Restore Independently adjustable pickup &
Modbus RTU
dropout of 3-phase U/O voltage, U/O Freq, Volts Balance plus
Ethernet Communications Fast Ethernet, (10/100 Mbit),
Phase Rotation
Modbus TCP/IP
Time Delays Gen start, Source 2 stabilize, Source 2 fail
Power Quality Metering True RMS metering, including THD%
override, Retransfer to Source 1, Gen cool down, Independent
(up to 8th order)
settings for Fast Test, Time Delay for Generator Voltage Sag
Load Shed Ability to transfer to de-energized normal source or
Remote Access All parameters locally (front USB port) or
center position in event of generator overload
remotely (serial or Ethernet) Adjustable
Integral Surge Protective Device (SPD) Load-connected
medium or high exposure type
Integral Battery Charger 3 or 10A, 12 or 24VDC type
Lugs Compression lugs in lieu of standard mechanical lugs on
100A-1200A switches
Lugs Mechanical or Compression lugs in lieu of standard rear-
bus connection on 1600-4000A switches
Z10 X
Amperage Ground Bus SPD Battery
A = 40 # of Poles NEMA Enclosure Voltage Code Metering & Accessories X = None (Load-Side Connected) Charger
B = 80 2 = 2 Pole X = None (Open) 70 = 277/480V, 3PH, 4W, 60Hz X = None 1 = Ground bus- 100A - 1200A Rating X = None
C = 100 3 = 3 Pole A = NEMA 1 20 = 120/240V, 1PH, 3W, 60Hz A = Load Shed X = None
D = PQ Metering Mech Lugs 1 = Battery
D = 150 4 = 4 Pole B = NEMA 1A 40 = 120/208V, 3PH, 4W, 60Hz (Qty. 3) #14-1/0-GB1 A = 65kA Charger-12
F = 225 C = NEMA 3R 92 = 220/380V, 3PH, 4W, 50Hz (see full product B = 80kA
2 = Ground bus- Volt-3 Amp
brochure for
G = 260 D = NEMA 3R w/Htr 50 = 480V, 3PH, 3W, 60Hz Mech Lugs C = 100kA
other options) 2 = Battery
I = 400 E = NEMA 4 38 = 120/208/240V, 3PH, 4W, (Qty. 6) #8-1/0 -GB2 1600A - 4000A Rating
Application F = NEMA 12 Charger-12
J = 600 High-Leg Delta, 60Hz X = None
(see full product Volt-10 Amp
K = 800 S = Util-Gen G = NEMA 4X 30 = 240V, 3PH, 3W, 60Hz D = 100kA
brochure for
L = 1000 U = Util-Util 31 = 208V, 3PH, 3W, 60Hz E = 150kA (see full product
other options)
M = 1200 G = Gen-Gen 61 = 347/600V, 3PH, 4W, 60Hz F = 200kA brochure for
N = 1600 G = 300kA other options)
(see full product brochure
O = 2000 for other options (see full product
Q = 3000 Control
brochure for
R = 4000 Group Options
other options)
Controller Language A = Group A Lug Options Communications
1 = English B = Group B X = Std lugs or Rear bus X = None
C = Group C (per chart below) S = CCM S-Modbus RTU (Serial) communication module
D = Group D
(see full product brochure E = CCM E Modbus TCP/IP (Ethernet) communication module
M = Group M
for lug option details) E = plus Modbus RTU (Serial) communication module
Application Notes
1. Metric dimensions (cm) and weights (Kg) shown in parenthesis
adjacent to English measurements in inches and pounds.
2. Includes 1.25" door projection beyond base depth. Allow a minimum
of 3" additional depth for projection of handle, light, switches,
pushbuttons, etc.
3. All dimensions and weights are subject to change without notice.
4. NEMA 3R, 4, 4X and 12 enclosure dimensions may differ than NEMA
1 shown above. Consult the factory for details.
5. Special lug arrangements may require different enclosure
dimensions. See full product brochure (DEA-405) for details.
6. Packing materials must be added to weights shown. Allow 15%
additional weight for cartons, skids, crates, etc.
7. Add 4" in height for removable lifting lugs.
8. Lug adapters for 3000-4000A limits may be staggered length for
ease of entrance. Consult the factory for details.
9. 1600-4000A switches have ventilation louvers on both sides and
rear of enclosure. Louvers must be clear for airflow with standard
cable connections.
ZTED Series
Low-Voltage, Delayed Transition, Automatic and Manual
Transfer Switches
Ideal for inductive (motors/transformers, UPS) mission
critical loads
Control Group Options (see order code)
Adjustable, time delay in centered off position
Mechanically interlocked center-off position for load decay Group A: All standard features, Field re-programmable I/O
Ratings 40 to 4000 amperes (4 inputs, 4 outputs), Control Switches (Test with Load, Test no
load, Fast Test, Alarm Reset, Auto/Man Re-transfer Source 1,
Ratings & Construction Auto/Man Transfer both sources, Preferred Source select,
Ratings Voltage, Ampere and Pole configuration per Commit/No Commit Transfer to Gen, Time Delay Bypass
Order Code Group B: All features from A plus: 10 User-configurable Analog
Certifications UL 1008, CSA C22.2 & 10 Digital Alarms, 20-channel data logger, 10-channel wave-
Certifications Third-party Seismic Certification to IBC 2009, form capture, Auto Load Shed (with voltage, frequency, and
3.2g @ Ip = 1.5 (operation during event) kW triggers)
Electrical Operator Momentarily energized, high-speed Group C: All features from B plus: 4 additional programmable
solenoid mechanism inputs (total 8 inputs, 8 outputs)
Mechanism Mechanically-held with mechanical interlock to Group D: All features from C plus: 4 additional field program-
inhibit connection of both sources to the load mable inputs (total 12 inputs, 12 outputs) & GE Flexlogic
Contacts GE design and manufactured, silver tungsten alloy user-configurable control logic
with separate arcing contacts on 600A and above ratings for Group M: Manual ATS configuration
high withstand and close-on capability
Additional Standard Features
Neutral Pole (4 pole only) Identical construction to phase
poles with fully rated main and arcing contacts. Operation via Engine Exerciser Configurable Periodic Exerciser (7 Event
same mechanism as phase poles to prevent sustained connec- Daily, Weekly, 14 or 28 day) or Clock Exerciser Type (21 Event,
tion of source neutrals in separately derived systems, as last- 365 day Programmable)
break/ first-make transfer. System Status Screen Active state of switch, display of all time
delays and alarm conditions
Controller Event Recorder 256 Event, 1ms accuracy, clock sync via
Construction Dual-processor based, with dedicated processor Network Time Protocol (NTP)
for high-speed Serial or Ethernet communications Outage & Test Report Screen Date/time stamping of: outage
Source Sensing Direct 120-690V sensing and software config- or test event, start signal sent, Gen start time, connection to
uration of rated voltage and frequency without the need for Gen, Max Gen Volts & Freq dip, return of utility, re-transfer
potential transformers, step-down transformers or DIP switches to normal
Control Wiring All customer connections at one location. All External Power Supply Standard 120VAC input for controller
signals in/out relay-isolated via DIN-mounted relay/terminal power and communication and 24 VDC input for remote control
blocks. All control wiring via factory-installed wiring harnesses. and annunciation when both sources de-energized
Enclosure Flexible Feature Assignment Field reassignable I/O for any/all
control features
Type per Order Code
Programmable Center-Off Position For transition of motor
Display, Sensing & Time Delays and regenerative loads
Display VGA color graphical with embedded HELP menus Optional Features (see order code)
Annunciation High intensity LED for Source Availability (2),
Serial Communications High speed, up to 115k Baud
Source Connected (2), Transfer Inhibit (not in Auto)
Modbus RTU
Source Fail/Restore Independently adjustable pickup &
Ethernet Communications Fast Ethernet, (10/100 Mbit),
dropout of 3-phase U/O voltage, U/O Freq, Volts Balance plus
Modbus TCP/IP
Phase Rotation
Time Delays Gen start, Source 2 stabilize, S1 g S2 transfer
Power Quality Metering True RMS metering, including THD%
(up to 8th order)
center-off delay, Source 2 fail override, Retransfer to Source 1,
S2 g S1 transfer center-off delay, Gen cool down, Independent
Load Shed Ability to transfer to de-energized normal source or
center position in event of generator overload
settings for Fast Test, Time Delay for Generator Voltage Sag
Integral Surge Protective Device (SPD) Load-connected
Remote Access All parameters locally (front USB port) or
medium or high exposure type
remotely (serial or Ethernet) Adjustable
Integral Battery Charger 3 or 10A, 12 or 24VDC type
Lugs Compression lugs in lieu of standard mechanical lugs on
100A-1200A switches
Lugs Mechanical or Compression lugs in lieu of
standard rear-bus
Z1D X
Amperage Ground Bus SPD Battery
A = 40 # of Poles NEMA Enclosure Voltage Code Metering & Accessories X = None (Load-Side Connected) Charger
B = 80 2 = 2 Pole X = None (Open) 70 = 277/480V, 3PH, 4W, 60Hz X = None 1 = Ground bus- 100A - 1200A Rating X = None
C = 100 3 = 3 Pole A = NEMA 1 20 = 120/240V, 1PH, 3W, 60Hz A = Load Shed X = None
D = PQ Metering Mech Lugs 1 = Battery
D = 150 4 = 4 Pole B = NEMA 1A 40 = 120/208V, 3PH, 4W, 60Hz (Qty. 3) #14-1/0-GB1 A = 65kA Charger-12
F = 225 C = NEMA 3R 92 = 220/380V, 3PH, 4W, 50Hz (see full product B = 80kA
2 = Ground bus- Volt-3 Amp
brochure for
G = 260 D = NEMA 3R w/Htr 50 = 480V, 3PH, 3W, 60Hz Mech Lugs C = 100kA
other options) 2 = Battery
I = 400 E = NEMA 4 38 = 120/208/240V, 3PH, 4W, (Qty. 6) #8-1/0 -GB2 1600A - 4000A Rating
Application F = NEMA 12 Charger-12
J = 600 High-Leg Delta, 60Hz X = None
(see full product Volt-10 Amp
K = 800 S = Util-Gen G = NEMA 4X 30 = 240V, 3PH, 3W, 60Hz D = 100kA
brochure for
L = 1000 U = Util-Util 31 = 208V, 3PH, 3W, 60Hz E = 150kA (see full product
other options)
M = 1200 G = Gen-Gen 61 = 347/600V, 3PH, 4W, 60Hz F = 200kA brochure for
N = 1600 G = 300kA other options)
(see full product brochure
O = 2000 for other options (see full product
Q = 3000 Control
brochure for
R = 4000 Group Options
other options)
Controller Language A = Group A Lug Options Communications
1 = English B = Group B X = Std lugs or Rear bus X = None
C = Group C (per chart below) S = CCM S-Modbus RTU (Serial) communication module
D = Group D
(see full product brochure E = CCM E Modbus TCP/IP (Ethernet) communication module
M = Group M
for lug option details) E = plus Modbus RTU (Serial) communication module
Application Notes
1. Metric dimensions (cm) and weights (Kg) shown in parenthesis adjacent to English
measurements in inches and pounds.
2. Includes 1.25" door projection beyond base depth. Allow a minimum of 3"
additional depth for projection of handle, light, switches, pushbuttons, etc.
3. All dimensions and weights are subject to change without notice.
4. NEMA 3R, 4, 4X and 12 enclosure dimensions may differ than NEMA 1 shown
above. Consult the factory for details.
5. Special lug arrangements may require different enclosure dimensions. See full
product brochure (DEA-405) for details.
6. Packing materials must be added to weights shown. Allow 15% additional weight
for cartons, skids, crates, etc.
7. Add 4" in height for removable lifting lugs.
8. Lug adapters for 3000-4000A limits may be staggered length for ease of entrance.
Consult the factory for details.
9. 1600-4000A switches have ventilation louvers on both sides and rear of enclosure.
Louvers must be clear for airflow with standard cable connections.
ZTECT Series
Low-Voltage, Closed Transition, Automatic and Manual
Transfer Switches
Ideal for mission critical loads (computer servers, HID
emergency lighting, data acquisition equipment)
Two source parallel time (bumpless transfer) of less than
Control Group Options (see order code)
100 milliseconds
Integrated backup protection to prevent extended Group A: All standard features, Field re-programmable I/O
parallel conditions (4 inputs, 4 outputs), Control Switches (Test with Load, Test no
Ratings 100 to 4000 amperes load, Fast Test, Alarm Reset, Auto/Man Re-transfer Source 1,
Auto/Man Transfer both sources, Preferred Source select,
Ratings & Construction Commit/No Commit Transfer to Gen, Time Delay Bypass
Ratings Voltage, Ampere and Pole configuration per Group B: All features from A plus: 10 User-configurable Analog
Order Code & 10 Digital Alarms, 20-channel data logger, 10-channel
Certifications UL 1008, CSA C22.2 waveform capture, Auto Load Shed (with voltage, frequency,
Certifications Third-party Seismic Certification to IBC 2009, and kW triggers)
3.2g @ Ip = 1.5 (operation during event) Group C: All features from B plus: 4 additional field
Electrical Operator Momentarily energized, high-speed programmable inputs (total 8 inputs, 8 outputs)
solenoid mechanism Group D: All features from C plus: 4 additional field
Mechanism Mechanically-held with highspeed transfer programmable inputs (total 12 inputs, 12 outputs) & GE Flexlogic
mechanism for make-beforebreak closed transition transfers user-configurable control logic
Contacts GE design and manufactured, silver tungsten alloy Group M: Manual ATS configuration
with separate arcing contacts on 600A and above ratings for
Additional Standard Features
high withstand and close-on capability
Neutral Pole (4 pole only) Identical construction to phase Engine Exerciser Configurable Periodic Exerciser (7 Event
poles with fully rated main and arcing contacts. Operation via Daily, Weekly, 14 or 28 day) or Clock Exerciser Type (21 Event,
same mechanism as phase poles to prevent sustained 365 day Programmable)
connection of source neutrals in separately derived systems, as System Status Screen Active state of switch, display of all
last-break/ first-make transfer. time delays and alarm conditions
Event Recorder 256 Event, 1ms accuracy, clock sync via
Controller Network Time Protocol (NTP)
Construction Dual-processor based, with dedicated processor Outage & Test Report Screen Date/time stamping of: outage
for high-speed Serial or Ethernet communications or test event, start signal sent, Gen start time, connection to Gen,
Source Sensing Direct 120-690V sensing and software Max Gen Volts & Freq dip, return of utility, re-transfer to normal
configuration of rated voltage and frequency without the External Power Supply Standard 120VAC input for controller
need for potential transformers, step-down transformers or power and communication and 24 VDC input for remote control
DIP switches and annunciation when both sources de-energized
Control Wiring All customer connections at one location. All Flexible Feature Assignment Field reassignable I/O for any/all
signals in/out relay-isolated via DIN-mounted relay/terminal control features
blocks. All control wiring via factory-installed wiring harnesses. Fail to Sync and Extended Parallel Protection Hardwired,
Enclosure independent controller
Type per Order Code Optional Features (see order code)
Display, Sensing & Time Delays Serial Communications High speed, up to 115k Baud
Modbus RTU
Display VGA color graphical with embedded HELP menus Ethernet Communications Fast Ethernet, (10/100 Mbit),
Annunciation High intensity LED for Source Availability (2), Modbus TCP/IP
Source Connected (2), Transfer Inhibit (not in Auto) Power Quality Metering True RMS metering, including THD%
Source Fail/Restore Independently adjustable pickup & (up to 8th order)
dropout of 3-phase U/O voltage, U/O Freq, Volts Balance plus Load Shed Ability to transfer to de-energized normal source
Phase Rotation or center position in event of generator overload
Time Delays Gen start, Source 2 stabilize, Source 2 fail Integral Surge Protective Device (SPD) Load-connected
override, Retransfer to Source 1, Gen cool down, Independent medium or high exposure type
settings for Fast Test, Time Delay for Generator Voltage Sag Integral Battery Charger 3 or 10A, 12 or 24VDC type
Remote Access All parameters locally (front USB port) or Lugs Compression lugs in lieu of standard mechanical lugs on
remotely (serial or Ethernet) Adjustable 100A-1200A switches
Lugs Mechanical or Compression lugs in lieu of standard rear-
bus connection on 1600-4000A switches
Z1C X
Amperage Ground Bus SPD Battery
C = 100 # of Poles NEMA Enclosure Voltage Code Metering & Accessories X = None (Load-Side Connected) Charger
D = 150 2 = 2 Pole X = None (Open) 70 = 277/480V, 3PH, 4W, 60Hz X = None 1 = Ground bus- 100A - 1200A Rating X = None
F = 225 3 = 3 Pole A = NEMA 1 20 = 120/240V, 1PH, 3W, 60Hz A = Load Shed X = None
D = PQ Metering Mech Lugs 1 = Battery
G = 260 4 = 4 Pole B = NEMA 1A 40 = 120/208V, 3PH, 4W, 60Hz (Qty. 3) #14-1/0-GB1 A = 65kA Charger-12
I = 400 C = NEMA 3R 92 = 220/380V, 3PH, 4W, 50Hz (see full product B = 80kA
2 = Ground bus- Volt-3 Amp
brochure for
J = 600 D = NEMA 3R w/Htr 50 = 480V, 3PH, 3W, 60Hz Mech Lugs C = 100kA
other options) 2 = Battery
K = 800 E = NEMA 4 38 = 120/208/240V, 3PH, 4W, (Qty. 6) #8-1/0 -GB2 1600A - 4000A Rating
Application F = NEMA 12 Charger-12
L = 1000 High-Leg Delta, 60Hz X = None
(see full product Volt-10 Amp
M = 1200 S = Util-Gen G = NEMA 4X 30 = 240V, 3PH, 3W, 60Hz D = 100kA
brochure for
N = 1600 U = Util-Util 31 = 208V, 3PH, 3W, 60Hz E = 150kA (see full product
other options)
O = 2000 G = Gen-Gen F = 200kA brochure for
(see full product brochure
Q = 3000 G = 300kA other options)
for other options
R = 4000 (see full product
Control
brochure for
Group Options
other options)
Controller Language A = Group A Lug Options Communications
1 = English B = Group B X = Std lugs or Rear bus X = None
C = Group C (per chart below) S = CCM S-Modbus RTU (Serial) communication module
D = Group D
(see full product brochure E = CCM E Modbus TCP/IP (Ethernet) communication module
M = Group M
for lug option details) E = plus Modbus RTU (Serial) communication module
Application Notes
1. Metric dimensions (cm) and weights (Kg) shown in parenthesis adjacent to English
measurements in inches and pounds.
2. Includes 1.25" door projection beyond base depth. Allow a minimum of 3" addi-
tional depth for projection of handle, light, switches, pushbuttons, etc.
3. All dimensions and weights are subject to change without notice.
4. NEMA 3R, 4, 4X and 12 enclosure dimensions may differ than NEMA 1 shown
above. Consult the factory for details.
5. Special lug arrangements may require different enclosure dimensions. See full
product brochure (DEA-405) for details.
6. Packing materials must be added to weights shown. Allow 15% additional weight
for cartons, skids, crates, etc.
7. Add 4" in height for removable lifting lugs.
8. 3000-4000A depth dimension shown is standard. Depending on your cable/con-
duit requirements, you may desire a deeper enclosure. Consult the factory for
further details.
9. 1600-4000A switches have ventilation louvers on both sides and rear of enclosure.
Louvers must be clear for airflow with standard cable connections.
ZBTE Series
Low-Voltage, Bypass/Isolation Open Transition, Automatic and
Manual Transfer Switches
Ideal for mixed (inductive and resistive) mission critical loads
Contact transfer speed less than 100 milliseconds
Control Group Options (see order code)
Bypass/Isolation for ease of ATS maintenance/testing without
load loss of power Group A: All standard features, Field re-programmable I/O (4
Ratings 100 to 4000 amperes inputs, 4 outputs), Control Switches (Test with Load, Test no
load, Fast Test, Alarm Reset, Auto/Man Re-transfer Source 1,
Ratings & Construction Auto/Man Transfer both sources, Preferred Source select,
Ratings Voltage, Ampere and Pole configuration per Commit/No Commit Transfer to Gen, Time Delay Bypass
Order Code Group B: All features from A plus: 10 User-configurable Analog
Certifications UL 1008, CSA C22.2 & 10 Digital Alarms, 20-channel data logger, 10-channel
Certifications Third-party Seismic Certification to IBC 2009, waveform capture, Auto Load Shed (with voltage, frequency,
3.2g @ Ip = 1.5 (operation during event) and kW triggers)
Electrical Operator Momentarily energized, high-speed Group C: All features from B plus: 4 additional field
solenoid mechanism programmable inputs (total 8 inputs, 8 outputs)
Mechanism Mechanically-held with mechanical interlock to Group D: All features from C plus: 4 additional field
inhibit connection of both sources to the load programmable inputs (total 12 inputs, 12 outputs) & GE Flexlogic
Contacts GE design and manufactured, silver tungsten alloy user-configurable control logic
with separate arcing contacts on 600A and above ratings for Group M: Manual ATS configuration
high withstand and close-on capability
Additional Standard Features
Neutral Pole (4 pole only) Identical construction to phase
poles with fully rated main and arcing contacts. Operation via Engine Exerciser Configurable Periodic Exerciser (7 Event
same mechanism as phase poles to prevent sustained Daily, Weekly, 14 or 28 day) or Clock Exerciser Type (21 Event,
connection of source neutrals in separately derived systems, as 365 day Programmable)
last-break/first-make transfer. System Status Screen Active state of switch, display of all time
delays and alarm conditions
Controller Event Recorder 256 Event, 1ms accuracy, clock sync via
Construction Dual-processor based, with dedicated processor Network Time Protocol (NTP)
for high-speed Serial or Ethernet communications Outage & Test Report Screen Date/time stamping of: outage
Source Sensing Direct 120-690V sensing and software or test event, start signal sent, Gen start time, connection to
configuration of rated voltage and frequency without the need Gen, Max Gen Volts & Freq dip, return of utility, re-transfer
for potential transformers, step-down transformers or to normal
DIP switches External Power Supply Standard 120VAC input for controller
Control Wiring All customer connections at one location. All power and communication and 24 VDC input for remote control
signals in/out relay-isolated via DIN-mounted relay/terminal and annunciation when both sources de-energized
blocks. All control wiring via factory-installed wiring harnesses. Flexible Feature Assignment Field reassignable I/O for any/all
Enclosure control features
In-Phase Monitor For phase matching prior to Live-Live
Type per Order Code
transfers of load
Display, Sensing & Time Delays
Optional Features (see order code)
Display VGA color graphical with embedded HELP menus
Serial Communications High speed, up to 115k Baud
Annunciation High intensity LED for Source Availability (2),
Modbus RTU
Source Connected (2), Transfer Inhibit (not in Auto)
Ethernet Communications Fast Ethernet, (10/100 Mbit),
Source Fail/Restore Independently adjustable pickup &
Modbus TCP/IP
dropout of 3-phase U/O voltage, U/O Freq, Volts Balance plus
Power Quality Metering True RMS metering, including THD%
Phase Rotation
(up to 8th order)
Time Delays Gen start, Source 2 stabilize, Source 2 fail
Load Shed Ability to transfer to de-energized normal source or
override, Retransfer to Source 1, Gen cool down, Independent
center position in event of generator overload
settings for Fast Test, Time Delay for Generator Voltage Sag
Integral Surge Protective Device (SPD) Load-connected
Remote Access All parameters locally (front USB port) or
medium or high exposure type
remotely (serial or Ethernet) Adjustable
Integral Battery Charger 3 or 10A, 12 or 24VDC type
Lugs Compression lugs in lieu of standard mechanical lugs on
100A-1200A switches
Lugs Mechanical or Compression lugs in lieu of standard rear-
bus connection on 1600-4000A switches
Z O X
Ground Bus SPD Battery
Product Type Operation Amperage # of Poles NEMA Enclosure Voltage Code Metering & X = None (Load-Side Connected) Charger
Z2*** = Bypass/ O = Open C = 100 2 = 2 Pole X = None (Open) 70 = 277/480V, 3PH, 4W, 60Hz Accessories
1 = Ground bus- 100A - 1200A Rating X = None
X = None
Isolation Vertical Transition D = 150 3 = 3 Pole H = NEMA 1 20 = 120/240V, 1PH, 3W, 60Hz A = Load Shed Mech Lugs X = None 1 = Battery
Construction F = 225 4 = 4 Pole w/Adapter Bay 40 = 120/208V, 3PH, 4W, 60Hz D = PQ Metering (Qty. 3) A = 65kA Charger-12
Z3** = Bypass/Isolation G = 260 I = NEMA 3R 92 = 220/380V, 3PH, 4W, 50Hz (see full product #14-1/0-GB1 B = 80kA Volt-3 Amp
Horizontal Construction I = 400 w/Adapter Bay 50 = 480V, 3PH, 3W, 60Hz brochure for 2 = Ground bus- C = 100kA
J = 600 J = NEMA 3R/Heater 38 = 120/208/240V, 3PH, 4W, other options) 2 = Battery
* 1600-3000 Amperage Application Mech Lugs 1600A - 4000A Rating
K = 800 & Thermostat/ High-Leg Delta, 60Hz Charger-12
Excluded S = Util-Gen (Qty. 6) X = None
L = 1000 Adapter Bay 30 = 240V, 3PH, 3W, 60Hz Volt-10 Amp
** Applicable to U = Util-Util #8-1/0 -GB2 D = 100kA
M = 1200 G = Gen-Gen K = NEMA 4 31 = 208V, 3PH, 3W, 60Hz E = 150kA (see full product
1600-3000 Amperage (see full product
N = 1600 w/Adapter Bay 61 = 347/600V, 3PH, 4W, 60Hz F = 200kA brochure for
brochure for
O = 2000 L = NEMA 12 (see full product brochure other options) G = 300kA other options)
P = 2600 Controller w/Adapter Bay for other options (see full product
Q = 3000 Language M= NEMA 4X Control brochure for
R = 4000 1 = English Controller Group Options Lug Options Communications other options)
w/Adapter Bay A = Group A X = Std lugs or Rear bus X = None
B = Group B (per chart below) S = CCM S-Modbus RTU (Serial) communication module
C = Group C E = CCM E Modbus TCP/IP (Ethernet) communication module
(see full product brochure
D = Group D E = plus Modbus RTU (Serial) communication module
for lug option details)
M = Group M
ZBTED Series
Low-Voltage, Bypass/Isolation Delayed Transition, Automatic and
Manual Transfer Switches
Ideal for inductive (motors/transformers, UPS) mission
critical loads Control Group Options (see order code)
Adjustable ATS time delay in center off position
Group A: All standard features, Field re-programmable I/O
Bypass/Isolation for ease of ATS maintenance/testing without
(4 inputs, 4 outputs), Control Switches (Test with Load, Test no
load loss of power
load, Fast Test, Alarm Reset, Auto/Man Re-transfer Source 1,
Ratings 100 to 4000 amperes
Auto/Man Transfer both sources, Preferred Source select,
Ratings & Construction Commit/No Commit Transfer to Gen, Time Delay Bypass
Ratings Voltage, Ampere and Pole configuration per Group B: All features from A plus: 10 User-configurable Analog
Order Code & 10 Digital Alarms, 20-channel data logger, 10-channel wave-
Certifications UL 1008, CSA C22.2 form capture, Auto Load Shed (with voltage, frequency, and
Certifications Third-party Seismic Certification to IBC 2009, kW triggers)
3.2g @ Ip = 1.5 (operation during event) Group C:All features from Bplus: 4 additional field programma-
Electrical Operator Momentarily energized, high-speed ble inputs (total 8 inputs, 8 outputs)
solenoid mechanism Group D:All features from Cplus: 4 additional field programma-
Mechanism Mechanically-held with mechanical interlock to ble inputs (total 12 inputs, 12 outputs) & GE Flexlogic user-
inhibit connection of both sources to the load configurable control logic
Contacts GE design and manufactured, silver tungsten alloy Group M: Manual ATS configuration
with separate arcing contacts on 600A and above ratings for Additional Standard Features
high withstand and close-on capability
Engine Exerciser Configurable Periodic Exerciser (7 Event
Neutral Pole (4 pole only) Identical construction to phase
Daily, Weekly, 14 or 28 day) or Clock Exerciser Type (21 Event,
poles with fully rated main and arcing contacts. Operation via
365 day Programmable)
same mechanism as phase poles to prevent sustained connec-
System Status Screen Active state of switch, display of all time
tion of source neutrals in separately derived systems, as last-
delays and alarm conditions
break/ first-make transfer.
Event Recorder 256 Event, 1ms accuracy, clock sync via
Controller Network Time Protocol (NTP)
Construction Dual-processor based, with dedicated processor Outage & Test Report Screen Date/time stamping of: outage
for high-speed Serial or Ethernet communications or test event, start signal sent, Gen start time, connection to
Source Sensing Direct 120-690V sensing and software config- Gen, Max Gen Volts & Freq dip, return of utility, re-transfer
uration of rated voltage and frequency without the need for to normal
potential transformers, step-down transformers or DIP switches External Power Supply Standard 120VAC input for controller
Control Wiring All customer connections at one location. All power and communication and 24 VDC input for remote control
signals in/out relay-isolated via DIN-mounted relay/terminal and annunciation when both sources de-energized
blocks. All control wiring via factory-installed wiring harnesses. Flexible Feature Assignment Field reassignable I/O for any/all
control features
Enclosure
Programmable Center-Off Position For transition of motor
Type per Order Code and regenerative loads
Display, Sensing & Time Delays Optional Features (see order code)
Display VGA color graphical with embedded HELP menus Serial Communications High speed, up to 115k Baud
Annunciation High intensity LED for Source Availability (2), Modbus RTU
Source Connected (2), Transfer Inhibit (not in Auto) Ethernet Communications Fast Ethernet, (10/100 Mbit),
Source Fail/Restore Independently adjustable pickup & Modbus TCP/IP
dropout of 3-phase U/O voltage, U/O Freq, Volts Balance plus Power Quality Metering True RMS metering, including THD%
Phase Rotation
Time Delays Gen start, Source 2 stabilize, S1 g S2 transfer
(up to 8th order)
Load Shed Ability to transfer to de-energized normal source or
center-off delay, Source 2 fail override, Retransfer to Source 1,
S2 g S1 transfer center-off delay, Gen cool down, Independent
center position in event of generator overload
Integral Surge Protective Device (SPD) Load-connected
settings for Fast Test, Time Delay for Generator Voltage Sag medium or high exposure type
Remote Access All parameters locally (front USB port) or re- Integral Battery Charger 3 or 10A, 12 or 24VDC type
motely (serial or Ethernet) Adjustable Lugs Compression lugs in lieu of standard mechanical lugs on
100A-1200A switches
Lugs Mechanical or Compression lugs in lieu of standard rear-
bus connection on 1600-4000A switches
Z D X
Ground Bus SPD Battery
Product Type Operation Amperage # of Poles NEMA Enclosure Voltage Code Metering & X = None (Load-Side Connected) Charger
Z2*** = Bypass/ D = Delayed C = 100 2 = 2 Pole X = None (Open) 70 = 277/480V, 3PH, 4W, 60Hz Accessories
1 = Ground bus- 100A - 1200A Rating X = None
X = None
Isolation Vertical Transition D = 150 3 = 3 Pole H = NEMA 1 20 = 120/240V, 1PH, 3W, 60Hz A = Load Shed Mech Lugs X = None 1 = Battery
Construction F = 225 4 = 4 Pole w/Adapter Bay 40 = 120/208V, 3PH, 4W, 60Hz D = PQ Metering (Qty. 3) A = 65kA Charger-12
Z3** = Bypass/Isolation G = 260 I = NEMA 3R 92 = 220/380V, 3PH, 4W, 50Hz (see full product #14-1/0-GB1 B = 80kA Volt-3 Amp
Horizontal Construction I = 400 w/Adapter Bay 50 = 480V, 3PH, 3W, 60Hz brochure for 2 = Ground bus- C = 100kA
J = 600 J = NEMA 3R/Heater 38 = 120/208/240V, 3PH, 4W, other options) 2 = Battery
* 1600-3000 Amperage Application Mech Lugs 1600A - 4000A Rating
K = 800 & Thermostat/ High-Leg Delta, 60Hz Charger-12
Excluded S = Util-Gen (Qty. 6) X = None
L = 1000 Adapter Bay 30 = 240V, 3PH, 3W, 60Hz Volt-10 Amp
** Applicable to U = Util-Util #8-1/0 -GB2 D = 100kA
M = 1200 G = Gen-Gen K = NEMA 4 31 = 208V, 3PH, 3W, 60Hz E = 150kA (see full product
1600-3000 Amperage (see full product
N = 1600 w/Adapter Bay 61 = 347/600V, 3PH, 4W, 60Hz F = 200kA brochure for
brochure for
O = 2000 L = NEMA 12 (see full product brochure other options) G = 300kA other options)
Q = 3000 Controller w/Adapter Bay for other options (see full product
R = 4000 Language M= NEMA 4X Control brochure for
1 = English Controller Group Options Lug Options Communications other options)
w/Adapter Bay A = Group A X = Std lugs or Rear bus X = None
B = Group B (per chart below) S = CCM S-Modbus RTU (Serial) communication module
C = Group C E = CCM E Modbus TCP/IP (Ethernet) communication module
(see full product brochure
D = Group D E = plus Modbus RTU (Serial) communication module
for lug option details)
M = Group M
ZBTECT Series
Low-Voltage, Bypass/Isolation Closed Transition, Automatic and
Manual Transfer Switches
Ideal for mission critical loads (computer servers, HID emergency
lighting, data acquisition equipment)
Control Group Options (see order code)
Two source parallel time (bumpless transfer) of less than
100 milliseconds Group A: All standard features, Field re-programmable I/O
Bypass/Isolation for ease of ATS maintenance/testing without (4 inputs, 4 outputs), Control Switches (Test with Load, Test no
load loss of power load, Fast Test, Alarm Reset, Auto/Man Re-transfer Source 1,
Ratings 100 to 4000 amperes Auto/Man Transfer both sources, Preferred Source select,
Commit/No Commit Transfer to Gen, Time Delay Bypass
Ratings & Construction Group B: All features from A plus: 10 User-configurable Analog
Ratings Voltage, Ampere and Pole configuration per & 10 Digital Alarms, 20-channel data logger, 10-channel wave-
Order Code form capture, Auto Load Shed (with voltage, frequency, and
Certifications UL 1008, CSA C22.2 kW triggers)
Certifications Third-party Seismic Certification to IBC 2009, Group C: All features from B plus: 4 additional field
3.2g @ Ip = 1.5 (operation during event) programmable inputs (total 8 inputs, 8 outputs)
Electrical Operator Momentarily energized, high-speed Group D: All features from C plus: 4 additional field
solenoid mechanism programmable inputs (total 12 inputs, 12 outputs) & GE Flexlogic
Mechanism Mechanically-held with highspeed transfer user-configurable control logic
mechanism for make-before break closed transition transfers Group M: Manual ATS configuration
Contacts GE design and manufactured, silver tungsten alloy
Additional Standard Features
with separate arcing contacts on 600A and above ratings for
high withstand and close-on capability Engine Exerciser Configurable Periodic Exerciser (7 Event
Neutral Pole (4 pole only) Identical construction to phase Daily, Weekly, 14 or 28 day) or Clock Exerciser Type (21 Event,
poles with fully rated main and arcing contacts. Operation via 365 day Programmable)
same mechanism as phase poles to prevent sustained connec- System Status Screen Active state of switch, display of all time
tion of source neutrals in separately derived systems, as last- delays and alarm conditions
break/first-make transfer. Event Recorder 256 Event, 1ms accuracy, clock sync via Net-
work Time Protocol (NTP)
Controller Outage & Test Report Screen Date/time stamping of: outage
Construction Dual-processor based, with dedicated processor or test event, start signal sent, Gen start time, connection to
for high-speed Serial or Ethernet communications Gen, Max Gen Volts & Freq dip, return of utility, re-transfer
Source Sensing Direct 120-690V sensing and software config- to normal
uration of rated voltage and frequency without the need for External Power Supply Standard 120VAC input for controller
potential transformers, step-down transformers or DIP switches power and communication and 24 VDC input for remote control
Control Wiring All customer connections at one location. All and annunciation when both sources de-energized
signals in/out relay-isolated via DIN-mounted relay/terminal Flexible Feature Assignment Field reassignable I/O for any/all
blocks. All control wiring via factory-installed wiring harnesses. control features
Enclosure Fail to Sync and Extended Parallel Protection Hardwired,
independent controller
Type per Order Code
Optional Features (see order code)
Display, Sensing & Time Delays
Serial Communications High speed, up to 115k Baud
Display VGA color graphical with embedded HELP menus Modbus RTU
Annunciation High intensity LED for Source Availability (2), Ethernet Communications Fast Ethernet, (10/100 Mbit),
Source Connected (2), Transfer Inhibit (not in Auto) Modbus TCP/IP
Source Fail/Restore Independently adjustable pickup & Power Quality Metering True RMS metering, including THD%
dropout of 3-phase U/O voltage, U/O Freq, Volts Balance plus (up to 8th order)
Phase Rotation Load Shed Ability to transfer to de-energized normal source or
Time Delays Gen start, Source 2 stabilize, Source 2 fail center position in event of generator overload
override, Retransfer to Source 1, Gen cool down, Independent Integral Surge Protective Device (SPD) Load-connected
settings for Fast Test, Time Delay for Generator Voltage Sag medium or high exposure type
Remote Access All parameters locally (front USB port) or Integral Battery Charger 3 or 10A, 12 or 24VDC type
remotely (serial or Ethernet) Adjustable Lugs Compression lugs in lieu of standard mechanical lugs on
100A-1200A switches
Lugs Mechanical or Compression lugs in lieu of standard rear-
bus connection on 1600-4000A switches
Z C X
Ground Bus SPD Battery
Product Type Operation Amperage # of Poles NEMA Enclosure Voltage Code Metering & X = None (Load-Side Connected) Charger
Z2*** = Bypass/ C = Closed C = 100 2 = 2 Pole X = None (Open) 70 = 277/480V, 3PH, 4W, 60Hz Accessories
1 = Ground bus- 100A - 1200A Rating X = None
X = None
Isolation Vertical Transition D = 150 3 = 3 Pole H = NEMA 1 20 = 120/240V, 1PH, 3W, 60Hz A = Load Shed Mech Lugs X = None 1 = Battery
Construction F = 225 4 = 4 Pole w/Adapter Bay 40 = 120/208V, 3PH, 4W, 60Hz D = PQ Metering (Qty. 3) A = 65kA Charger-12
Z3** = Bypass/Isolation G = 260 I = NEMA 3R 92 = 220/380V, 3PH, 4W, 50Hz (see full product #14-1/0-GB1 B = 80kA Volt-3 Amp
Horizontal Construction I = 400 w/Adapter Bay 50 = 480V, 3PH, 3W, 60Hz brochure for 2 = Ground bus- C = 100kA
J = 600 J = NEMA 3R/Heater 38 = 120/208/240V, 3PH, 4W, other options) 2 = Battery
* 1600-3000 Amperage Application Mech Lugs 1600A - 4000A Rating
K = 800 & Thermostat/ High-Leg Delta, 60Hz Charger-12
Excluded S = Util-Gen (Qty. 6) X = None
L = 1000 Adapter Bay 30 = 240V, 3PH, 3W, 60Hz Volt-10 Amp
** Applicable to U = Util-Util #8-1/0 -GB2 D = 100kA
M = 1200 G = Gen-Gen K = NEMA 4 31 = 208V, 3PH, 3W, 60Hz E = 150kA (see full product
1600-3000 Amperage (see full product
N = 1600 w/Adapter Bay 61 = 347/600V, 3PH, 4W, 60Hz F = 200kA brochure for
brochure for
O = 2000 L = NEMA 12 (see full product brochure other options) G = 300kA other options)
P = 2600 Controller w/Adapter Bay for other options (see full product
Q = 3000 Language M= NEMA 4X Control brochure for
R = 4000 1 = English Controller Group Options Lug Options Communications other options)
w/Adapter Bay A = Group A X = Std lugs or Rear bus X = None
B = Group B (per chart below) S = CCM S-Modbus RTU (Serial) communication module
C = Group C E = CCM E Modbus TCP/IP (Ethernet) communication module
(see full product brochure
D = Group D E = plus Modbus RTU (Serial) communication module
for lug option details)
M = Group M
ZBTECT Model Closed Transition UL 1008 Withstand and Closing Ratings Switch Size Amps Cables/Pole Wire Ranges
ZBTECT
Transfer/Bypass-Isolation Switches Please refer to GE Publication TB-1102
100, 150, 225, 260, 400 1 #4 to 600 MCM
The ZTECT Closed Transition Transfer Switch 600 2 #2 to 600 MCM
may be applied with a bypass-isolation switch 800, 1000, 1200 4 #2 to 600 MCM
for the utmost in reliability and versatility. The 1600, 2000, 2600, 3000, 4000 * *
E9000
Motor Control Centers Introduction .......................................15-2 EVOLUTION SERIES E9000/8000 Low Voltage
EVOLUTION SERIES E9000 Key Benefits ...............................15-3 Motor Control Centers
Motor Control Centers Features (SC/MC Program)..............15-4
Product References:
GE Fastrac Program MCC Units Quick Selection Guide, E9000 Engineered Products Catalog Section 10
Motor Control Starter Units.................................................................15-5 Application and Selection Guide E9000 DET291A
Motor Control Feeder Units.................................................................15-9 Application and Selection Guide Spectra/8000 GET6729
Introduction
GE motor control centers offer an ideal means of quickly providing
centralized motor control and other related control equipment.
A pre-engineered version of the GE motor control center is avail-
able at short-cycle and mid-cycle shipment. The product scope
available is more limited than with normal cycle shipments, and
includes certain combination starter units, feeder units, distribu-
tion transformers, lighting panels, relaying panels, programmable
controllers and other miscellaneous devices to be installed in a
single, floor-mounted enclosure and fed from a common
enclosed horizontal and vertical bus system.
Each GE motor control center vertical section is constructed of
0.090-inch (13-gauge) steel which is subjected to a special corro-
sion-resistant zinc-phosphate treatment followed by a powder
paint process using ANSI-61 light gray alkyd-enamel paint. Refer
to the factory for additional color options. Each section houses
the horizontal and vertical bus, horizontal and vertical wireways
and the compartmentalized individual control units. Standard
unit construction is Class I Type B wiring1. Factory assembled,
wired and tested units are mounted in each vertical section,
and sections are easily bolted together to form a motor control
center line-up. The entire line-up is then powered by a single
incoming-line connection.
Standard UL labeled NEMA 1 enclosure contains 600-ampere,
three-phase, copper tin-plated horizontal main bus, 300-ampere,
three-phase, copper tin-plated vertical bus and is braced to
withstand a fault current of 65,000 rms symmetrical. Each verti-
cal section must be priced to include 72 inches of vertical space
units consisting of starters, feeders, transformers, panels, incom-
ing terminal boards and/or enclosure spaces for future units.
1Typical diagrams can be found in the Application and Selection Guide for DET291
Section L.
Safety:
No Hot bus rework up to 600A
Hi-Visible Trip Indication
Door and unit interlocks
UBC Seismic Zone 4 Standard
Six Sigma Designed
Size:
6" reductionSz 3, 5
6" to 36" reduction VFDs
6" Size 1 FVNR
6" 150A Feeder
12" 250A Feeder
36" Size 5 Plug-In, two in a section
300VA CPTNo additional Space
Plug In Buckets to Size 5
Plug In Feeders to 600A
Simplicity:
Easy Unit Insertion/Removal
Snap-In Shelves
Easily Quoted Fastrac MCCs
Manufacturing Flexibility
Scope:
450 Hp VFDs
500 Hp SSS
250A and 600A Stabs
TVSS 65-200K Surge Current
Automatic Transfer Switches to 1200A
This Quick Selection Guide covers Control Center starters and 2 Select Starter Type and Size
feeders, including full and reduced voltage, reversing and non- Find the starter type required. Transfer the product number digits
reversing, two-speed single and dual winding starters, in sizes to the boxes marked 2 in the product number.
1-5. It also covers EVOLUTION SERIES E9000 Sections. For
other units, see the Engineered Products Catalog, Section 10. Starter Type Size Product Number Digits
1 H1 1
H/O/A SW. RED LGT STD AB* OB* F/S/O/A SW R/A LGT PTT FP TP
H/O/A SW. R/G LGT STD AC* OC* F/S/O/A SW R/A/G LGT PTT FQ TQ
1 2 3 4 5 6 7 8 9 10
Starter
Product
Number
Select motor control center type. Transfer the product number SELT
150 65 65 25 12 SEL2
digit to the box marked 1 in the product number line. 150 65 65 25 6 SEL8
150 65 12 SLL2
MCC Type Product Number Digit SELT-L
150 65 6 SLL8
EVOLUTION SERIES E9000 E 150 100 100 25 12 SEP2
SEPT
150 100 100 25 6 SEP8
2 Select Feeder Disconnect Type
SFLT 250 65 65 25 12 SFLT
Select disconnect type. Transfer the product number digits to the SFPT 250 100 100 25 12 SFPT
boxes marked 2 in the product number line. SGL1C
150 100 65 65 24 GLI1
w-LT & INST
Type Voltage Product Number Digits
SGL1C
Circuit Breaker FB 150 100 65 65 24 LIG1
w-LT/INST & GF
Fusible Switch-R 208/240V FR SGL4C
400 100 65 65 24 GLI4
Fusible Switch-R 480/600V FS w-LT & INST
Transfer the product number digits to the boxes marked 3 in the 30 100 100 100 12 QMR3
product number line. 60 100 100 100 12 QMR6
FSW
Amps Product Number Digits Amps Product Number Digits 100 100 100 N/A 12 QMR1
6
6" EK06 6 EK30
30"
12" EK12 36" EK36
18" EK18 42" EK42
24" EK24 48" EK48
1 2 3 4 5 6 7 8 9 10 11 12 13
Section
Product
Number L E F
This Quick Selection Guide covers Control Center starters and 2 Select Starter Type and Size
feeders, including full and reduced voltage, reversing and non- Find the starter type required. Transfer the product number digits
reversing, two-speed single and dual winding starters, in sizes to the boxes marked 2 in the product number line.
1-5. For other units, see the Engineered Products Catalog,
Starter Type Size Product Number Digits
Section 10.
1 A1
Motor Control Starter Units 2 A2
FVNR
For each of the following steps, find the optionMCC type, starter 3 A3
type, size, disconnect, control power, pilot lights, etc. that meets 4 A4
S 4 D4
3 E3
RVNR
4 E4
1 2 3 4 5 6 7 8 9 10
Starter
Product
Number
l
boxes marked 2 in the product number line. 150 100 100 25 18 SEP8
SFLT 225 65 65 25 18 SFLT
Type Voltage Product Number Digits
SFPT 225 100 100 25 18 SFPT
Circuit Breaker FB
30 100 100 100 6 QM36
Fusible Switch-R 208/240V FR
30 100 100 100 12 QMR3
Fusible Switch-R 480/600V FS
60 100 100 100 6 QM66
Fusible Switch-J 480/600V FJ FSW
60 100 100 100 12 QMR6
100 100 100 25 12 QMR1
3 Select Amp Rating
200 100 100 100 24 QMR2
Select amp rating for either circuit breaker trip or Class R fuse. 1 150A unit is 18" high.
Transfer the product number digits to the boxes marked 3 in the
product number line.
5 Select System Voltage
Amps Product Number Digits Amps Product Number Digits Select system voltage. Transfer the product number digit to
15 015 110 110 the box marked 5 in the product number line.
20 020 125 125
Voltage Product Number Digit
30 030 150 150
480V 60 Hz A
40 040 175 175
208V 60 Hz B
50 050 200 200
240V 60 Hz C
60 060 225 225
575V 60 Hz D
70 070 250 250
380V 50 Hz E
80 080 400 400
90 090 600 600 Standard Feeder Unit Product Number
100 100
1 2 3 4 5
Renewal Parts
MCC Type
Parts Description 7700 8000 Spectra Product Number
Shelf-Standard X X X 68J210383BBXXXXXXY
Shelf Support X X X 117B5044P2
Vertical Bus Parts
Bus Shutter Assembly X X X 204B4153BVG1
Door Latch X X X 169C6386DMG2
Muffin Fan X X X 272A5509SDP1
Cooling Fans
Tarzan Fan X X X RMC#020169
6" x 20" X X X 204B4127G19
Wireway Covers 12" x 20" X X X 204B4127G20
18" x 20" X X X 204B4127G21
Size 1 All X X 204B4142BDG1
Size 1 All X 116C8961G1
Size 2 All X 116C8961G2
Size 2 FVNR X X 204B4142BDG2
Size 2 FVR - 2 Speed X X 204B4142BDG3
O/L Reset Assy Size 3 & 4 All X 116C8961G32
Size 3 & 4 FVNR-FVR-2 Speed X X 204B4142BDG42
Size 3 & 4 RVNR X X 204B4142BDG52
Size 5 All X 116C8961G5
Size 5 All X X 204B4142BDG6
60VA (With Fuse Block) X X X 302A3600YDP201
150VA (With Fuse Block) X X X 302A3600YDP204
Control Power Transformer
300VA (With Fuse Block) X X X 302A3600YDP207
300VA (No Fuse Block) X X X 302A3600YDP7
Male - 3 Point X X 75B132504G701
Standard TB
Female - 3 Point X X 204B4153APG1
Male - 3 Point X X 75B132504G701
Female - Size 1 & 2 - 3 Point (w/lugs) X X 204B4153APG2
Power TB
Size 3 - 3 Point X X 204B4050WDG5
Size 4 - 3 Point X X 204B4050WDG1
High Density TB 6 Point-Control X X CR151KPP56F
6" High X 273A7764G61
12" High X 273A7764G121
18" High X 273A7764G181
24" High X 273A7764G241
Filler Kit - 7700 Line
30" High X 273A7764G301
36" High X 273A7764G361
42" High X 273A7764G421
48" High X 273A7764G481
6" High X 204B4145AMG11
12" High X 204B4145AMG21
18" High X 204B4145AMG31
24" High X 204B4145AMG41
Filler Kit - 8000 Line
30" High X 204B4145AMG51
36" High X 204B4145AMG61
42" High X 204B4145AMG71
48" High X 204B4145AMG81
6" High X 68J210397DAXX06XXB
12" High X 68J210397DAXX12XXB
18" High X 68J210397DAXX18XXB
24" High X 68J210397DAXX24XXB
Blank Spectra Door
30" High X 68J210397DAXX30XXB
36" High X 68J210397DAXX36XXB
42" High X 68J210397DAXX42XXB
48" High X 68J210397DAXX48XXB
6" High X 272A5650BVP9
12" High X 272A5650BVP10
18" High X 272A5650BVP11
24" High X 272A5650BVP12
Spectra Fill Strip
30" High X 272A5650BVP13
36" High X 272A5650BVP14
42" High X 272A5650BVP15
48" High X 272A5650BVP16
Left X X 117B5027P2
Right X X 117B5027P3
Door Hinges
Spectra Hinge X 204B4145FZP1
Spectra Hinge Pin X 273A7728TLP1
20" Wide X X X 68J210375DB2090XXB
Rear Doors
24" Wide X X X 68J210375DB2490XXB
20" Wide X X X 68J120323LE0102AAB3
Rear Covers
24" Wide X X X 68J120323XA0102AAB3
1Includes blank door, shelf, shelf support and hinged filler strip.
2O/L types. Refer to factory
3Flat covers for 13" MCC
Note: Contact Factory for pricing.
Bucket Type Individual Part Type NEMA Size Height (in.) MCC Type Product Number
1 12" Other 204B4054G10
Disconnect
2 12" Other 204B4054G26
3 30" Other 204B4054G62
Fused Switch N/A
4 42" Other 204B4056G15
1 12" Other 8000L8G2
Stab Harness
2 12" Other 8000L8G8
4 30" Spectra 8000L4G47
Stab Harness 3 24" Spectra 8000L4G48
N/A N/A Spectra 8000L8G21
1 12" Spectra CR306C002ACET
N/A N/A Spectra CR306D002LVH
Starter
3 24" Spectra CR306E002LVH
4 30" Spectra CR306F002LVH
1 12" Spectra CSC#ATMR1/2
CPT Fuse Primary 2 12" Spectra CSC#ATMR1
4 30" Spectra CSC#ATMR2
Spectra Circuit Breaker 2 12" Spectra CSC#TR1-6/10R
CPT Fuse Secondary 4 30" Spectra CSC#TR3-2/10R
1 12" Spectra CSC#TR6/10R
1 12" Spectra SELA36AI0007
2 12" Spectra SELA36AI0030
Disconnect
3 24" Spectra SELA36AI0100
4 30" Spectra SFLA36AI0250
3 24" Spectra SRPE100A70
2 12" Spectra SRPE30A25
Rating Plug
1 12" Spectra SRPE7A3
4 30" Spectra SRPF250A150
Bucket Type NEMA Size Horsepower Height (in.) MCC Type Product Number
1/4 12" Other MA1F1AB2J.25A
1/3 12" Other MA1F1AB2J.33A
3/8 12" Other MA1F1AB2J.38A
1/2 12" Other MA1F1AB2J.50A
3/4 12" Other MA1F1AB2J.75A
1 12" Other MA1F1AB2J001A
1
2 12" Other MA1F1AB2J002A
3 12" Other MA1F1AB2J003A
5 12" Other MA1F1AB2J005A
10 12" Other MA1F1AB2J010A
Fused Switch 1 1/2 12" Other MA1F1AB2J1.5A
7 1/2 12" Other MA1F1AB2J7.5A
15 12" Other MA2F1AB2J015A
2 20 12" Other MA2F1AB2J020A
25 12" Other MA2F1AB2J025A
30 30" Other MA3F1AB2J030A
3 40 30" Other MA3F1AB2J040A
50 30" Other MA3F1AB2J050A
60 42" Other MA4F1AB2J060A
4 75 42" Other MA4F1AB2J075A
100 42" Other MA4F1AB2J100A
1/4 12" Spectra MA1U1AB2J.25A
1/3 12" Spectra MA1U1AB2J.33A
3/8 12" Spectra MA1U1AB2J.38A
1/2 12" Spectra MA1U1AB2J.50A
3/4 12" Spectra MA1U1AB2J.75A
1 12" Spectra MA1U1AB2J001A
1
2 12" Spectra MA1U1AB2J002A
3 12" Spectra MA1U1AB2J003A
5 12" Spectra MA1U1AB2J005A
10 12" Spectra MA1U1AB2J010A
Spectra Circuit Breaker 1 1/2 12" Spectra MA1U1AB2J1.5A
7 1/2 12" Spectra MA1U1AB2J7.5A
15 12" Spectra MA2U1AB2J015A
2 20 12" Spectra MA2U1AB2J020A
25 12" Spectra MA2U1AB2J025A
30 24" Spectra MA3U1AB2J030A
3 40 24" Spectra MA3U1AB2J040A
50 24" Spectra MA3U1AB2J050A
60 30" Spectra MA4U1AB2J060A
4 75 30" Spectra MA4U1AB2J075A
100 30" Spectra MA4U1AB2J100A
NOTES:
Introduction.................................................................................16-1
AKD-10 Low-Voltage Switchgear ............................................16-3
AKD-20 Low-Voltage Switchgear ............................................16-3
Arc Vault Arc Flash Protection System ................................16-4
CSI Specifications
Low Voltage Metal Enclosed
16400 Low Voltage Switchgear
26 23 00 Low Voltage Switchgear
Medium Voltage
M Power Meters
Circuit
Breakers
High Pressure
Contact Switches
Switchgear and
Switchboards
Automatic Transfer Switch
1 2 4
FVNR FVNR FVNR Reactor
VFD
Distribution
Y
M M M M Transformers
Capacitors and Panelboards and
Motors Harmonics Filters Lighting Panels
Lighting Controls
Voltage
Regulators
Safety
Ballasts M Switches
Luminaires
and Lamps
Power
Ethernet Monitoring
Software
Network Design
and Equipment
Hub
Instructions/Maintenance
Low Voltage Switchgear
AKD-10 Application Guide DET-196
WAVEPRO Low Voltage Power Circuit Breaker
Application Guide DET-167
User Publication Summary DEE-194
Stop Arc Flash in Its Tracks With the Fastest Arc Flash
Containment Technology Available.
GEs innovative Arc Vault takes a different approach. It doesnt
exhaust the arc flash; it extinguishes it. Arc Vault can stop an
arcing fault in less than eight milliseconds, a fraction of the time
that traditional systems need to stop a flash.
Reference Publications
Arc Vault Application Guide DEH-41484
Arc Vault Installation Operation and Maintenance Manual DEH-41483
Entellisys 5.0 is the sensible choice to save you money over the Entellisys is becoming the preferred solution in critical applica-
lifetime of your system. tions such as data centers, hospitals, petro/chem facilities and
airports around the world. State-of-the-art protection, monitoring
Entellisys Low-Voltage Switchgear is the first system to provide and control make it the intelligent choice to provide reliable power
the power of knowledge about the entire switchgear lineup. distribution now and in the future.
This power can be used: Contact your account manager and request a financial savings
by the engineer to improve protection, report, customized for your application.
by the installing contractor to shorten installation time,
by the operator to stay out of the arc flash zone, Layout and sizing .......................................................................17-2
by the maintenance personnel to save maintenance time
and money, and
by the owner to adapt the equipment to the dynamic needs
of the facility.
Entellisys indoor low voltage switchgear height is 92" (97" over 6. Front busway connections to a circuit breaker require a blank
the top wiring trough and 103.5" over the optional breaker hoist). compartment above the breaker for busway above or a blank
The available breaker stacking space is 84". compartment below the breaker for busway below.
7. Use of fused breakers does not necessarily require 200kA bus
Breaker frame size and type determine the width of the breaker bracing. Bus bracing should be based on the available short
sections and also the minimum depth of the switchgear line-up. circuit current on the switchgear bus.
Refer to tables below for properly sizing Entellisys line-ups. The
8. 200kA bus bracing can limit feeder breaker placement. 200kA
depth of the entire line-up is determined by the deepest device in
bus bracing does not allow adjacent 22 inch wide sections.
the line-up. For example, a line-up with an EGF-20 breaker with a
fuse roll-out (depth 60") and EGF-08 breakers (depth 67") would 9. Factory review of layout is required for bus bracing greater
be a minimum of 67" deep the EGF-08 being the deepest device. than 100kA
Also refer to the section arrangements on the following pages for 10. Some cable entrance designs are not suitable for service
available breaker stacking configurations. entrance. Consult the factory if service entrance is required
for the incoming cable section.
Switchgear Layout Considerations
11. Additional cable and conduit space is available by making
breaker sections wider (22 inch wide to 30 inch wide or 30
1. Sections can be bussed together if there are matching bus
inch wide to 38 inch wide) or by making the line-up deeper
levels in the adjacent sections. Refer to the sample Entellisys
(7 or 14 inches). Refer to the tables below.
line-up.
2. Any breaker compartment shown on the section drawings
can be made blank to provide additional space for mounting
Entellisys devices. Indoor Enclosure Depth Options
Available Depth Options
3. The ampere ratings shown beside each breaker symbol Front compartment 30" 37"
indicate the range of frame sizes that are allowed in the
particular section arrangement. This takes into consideration Rear compartment
(Std depth or 7" or
the temperature rise in the section due to breaker loading. 30" (std) 37" (7" ext) 44" (14" ext) 30" (std) 37" (7" ext) 44" (14" ext)
14" rear extension)
Refer to ANSI C37.20.1-2002 para 8.4.2.3 for cumulative circuit
breaker loading guidelines.
Total depth 60" 67" 74" 67" 74" 81"
4. Devices cannot be mounted on breaker cubicle doors.
5. 3200A, 4000A, and 5000A fuse roll-outs are the same size as
their respective breakers, therefore any compartment shown
with a 3200, 4000, or 5000 amp breaker will also accommo-
date a fuse roll-out and vice versa.
Breaker Device Combination Frame Size Breaker Cubicle Minimum Section Minimum Equipment Depth Optional Equipment
Type or Bus Rating (Amperes) Vertical Height (Inches) Width3 (Inches) [Front/Rear Compt] (Inches) Depth (Inches)
EGS-08 800 21 22 60 [30/30] 67/74
EGH-08 800 21 22 60 [30/30] 67/74
EGX-08 800 21 22 60 [30/30] 67/74
EGF-08 800 21 22 67 [37/30] 74/81**
EGS-16 1600 21 22 60 [30/30] 67/74
EGH-16 1600 21 22 60 [30/30] 67/74
EGF-16 1600 21 22 67 [37/30] 74/81**
EGS-20 2000 21 22 60 [30/30] 67/74
EGF-20 with fuse roll-out 2000 56 30 60 [30/30] 67/74/812
EGS-32 3200 35 30 60 [30/30] 67/74/812
EGH-32 3200 35 30 60 [30/30] 67/74/812
EGX-32 3200 35 30 60 [30/30] 67/74/812
EGF-32 with fuse roll-out 3200 84 38 67 [37/30] 74/81**
EGS-40 4000 35 30 60 [30/30] 67/74/812
EGX-40 4000 35 30 60 [30/30] 67/74/812
EGF-40 with fuse roll-out 4000 84 38 67 [37/30] 74/81**
EGS-50 5000 35 38 74 [37/37] 81**
EGX-50 5000 35 38 74 [37/37] 81**
EGF-50 with fuse roll-out1 5000 35 38 74 [37/37] 81**
1600-4000A main bus rating 60 [30/30] 67/74/812
5000A main bus rating 67 [30/37] 74/812
1 Breaker and fuse roll-out must be mounted in separate vertical sections.
2 81" depth available only when these devices are used in a line-up with items identified with **.
3 Section width can be increased for additional cable / conduit space. 22" sections can be increased to 30" wide, 30" wide sections can be increased to 38" wide.
MV One Line.................................................................................18-2
Motor Control Medium Voltage (Limitamp)
Introduction, Features, Types, Options, References ................18-3
Specifications, Ratings, Equipment
Reference Publications ......................................................................18-4
Product Scope ...........................................................................................18-5
Renewal Parts............................................................................................18-6
Switchgear Type Power/Vac
Introduction, Publications....................................................................18-8
Power/Vac Vacuum Metalclad Switchgear,
and Breakers...........................................................................................18-9
Characteristics, Symmetrical Rating Basis ...............................18-10
Vacuum Circuit Breakers and Frames ........................................18-11
Utility
MV 50 50 50 50
Switchgear 51 51 51 51
MV Circuit
52 52 52 52 52
Breakers
Capacitor
Banks
Auto-Transfer
Switches
MV
Fuses
MV Load Secondary Sub-
Interrupter station Transformers
Switches
Low Voltage
MV Motor Control
and Drives
MV Motors M M M M
Power Monitoring
Ethernet Software
Network Design
and Equipment
Hub
Matching line-up with all existing Limitamps DET-064 Advertising Brochure Bloomington1
Auxiliary sections available for the Limitamp AR GEF-8016 Contactor Renewal Parts Mebane
GEH-5306 Contactor Maintenance Instructions Bloomington1
Fuses/Curves
Typical Current Ratings (amps) 2 HI only GES-5000 Power Fuse Curves Bloomington1
Non-vented: 320 top/320 bottom GEP-1260 Control CatalogCovers Full Line of Products Bloomington1
IC1074 1200A6 1200A vented w/o fuse 1000A & 2000A ITI
Load Break Switch 38 kA rms sym. 1000A non-vented w/o fuse Ferraz
3600A12 38W x 90H x 30D N/A stationary
(stationary) 4.76 kV (fused) 960A vented with fuse Shawmut
(2800A non-vented) drawout
(main, feeder, or tie) 840A non-vented with fuse
Auxiliary Sections7 1000A & 2000A 90H x 30D ITI
38 kA rms sym.
(incoming line,
4.76 kV
Per devices installed 3600A12 any width available N/A N/A stationary
metering auxiliary) (2800A non-vented) (22" minimum) drawout
NOTES:
1 Copper only, silver or tin plating, insulation available.
2 NEMA 1 only, gasketing available. NEMA 2, 12, 3R available.
3 CR324 is ambient-compensated.
4 With primary and secondary fuses. Remote control power available.
5 Mechanical latch available. Capacitor trip device also available with latched contactor.
6 A switch may be used for isolation only.
7 Surge arresters available: GE #9L11XPB Polymer series.
8 Epoxy-coated.
9 Obsolete design-for replacement only.
10 Multilin 239, 269, 369, 469 available.
11 7.2 kV application available.
12 Adds 12 inches to depth.
13 Available in Arc Resistant Type 2B.
14 24 inch top for Plenum in AR version.
15 AR version not available in 26 and 34 1-high.
This is a partial listing of GE's medium voltage power fuse offering. GE offers current limiting fuses for a large variety of applications, including full range fuses, potential
transformer fuses, motor starters, capacitor fuses, supports, disconnect switches, and a variety of fuse clips and live parts.
For more information, please contact your local GE distributor, or local GE Energy sales representative. Our catalog (GEP-9013B),
as well as other application and selection information are also available at www.geindustrial.com. If you need further assistance you may contact our
customer service group at 1-800-821-4873 (US only).
Instructions/Maintenance
Power/Vac Vacuum Circuit Breaker
with ML-17H-4 Rev. 0 and -1 Mechanism 01.4IB.66000A
Power/Vac Vacuum Circuit Breaker
with ML-18 Mechanism Type VB1 (This mechanism no longer in production) GEK-86132
Power/Vac Vacuum Circuit Breaker
with ML-17 Mechanism Models 0, -1, -2, -3 (Previous production design) GEK-39671
Power/Vac Metalclad Switchgear Types 4.16
and 13.8 Installation and Maintenance GEK-39672
Metalclad Switchgear Components (Full Height Frame)
for Power/Vac Circuit Breaker GEK-90209
Metalclad Switchgear Components Box and L frame
for Power/Vac Circuit Breaker GEK-90215
Power/Vac Compartment Kits GEK-103201
Renewal Parts - Power/Vac Vacuum Circuit Breaker
with ML17 Mechanism Models 0, -1, -2, -3 GEF-4705
Renewal Parts - Power/Vac Vacuum Circuit Breaker
with ML18 Mechanism GEK-90218
1500 mVA Bkr GEK-39671 + DEI-002
Power/Vac 27kV Circuit Breaker
with ML-20 Mechanism DEH-40368
Power/Vac switchgear is designed, assembled and tested to Remote Racking/Control options are available for increased
meet or exceed applicable ANSI, IEEE and NEMA standards. UL safety, and to meet NFPA 70E-2004.
Listing is available as option when requested on breakers and NEMA 1, NEMA 3R and NEMA 3R Walk-in Construction available
cubicles depending on device compliment. Power/Vac Ample relay and terminal block space accepts complex config-
switchgear incorporates the compartment concept with urations. Open doors are securely held with positive stops
grounded metal barriers that segregate primary functions so no so breakers can be inserted or withdrawn without damaging
live parts are exposed. Safety interlocks are standard as well as control, indication or protective devices.
closed door racking and storage, breaker position indicator, and Consistent top-quality manufacturing at ISO-9002 listed facility.
positively-actuated safety shutters. Power/Vac metalclad
switchgear combines the time-honored advantages of GE ANSI
designed metalclad switchgear flexibility, quality and economy, Power/Vac Breaker
along with the benefits of copper-chrome improved Vacuum interrupters provide rapid arc interruption and are not
reliability, longer life, design simplicity, less maintenance, reduced affected by the external environment.
size and weight. Vacuum interrupter contacts require no maintenance and
Furthermore, two-high breaker stacking (one breaker above seldom wear out over the normal duty life-span of a circuit
another in a single vertical section) means added application breaker.
freedom and significant floor space savings. Power/Vac metal- Contact erosion indicator is provided for inspection
clad switchgear incorporates standardized modular construction convenience.
to simplify system planning and lower installation cost. These Primary disconnect fingers are rugged and easy to inspect.
economies are enhanced by the availability of structured protec- Built of silver-plated copper and tested for continuous and
tion, instrumentation and control packages. momentary currents, these disconnects provide proper contact
integrity throughout the life of the gear.
Power/Vac switchgear is designed to meet a wide variety Breaker ratings: 4.76 kV-20KA through 15 kV-63kA, 1200
of protection and switching applications. All functional units such Amperes to 4000 Amperes
as incoming line, radial feeders, feeder bypass, bus-tie, bus- Interrupter support of track resistant polyester glass houses
entrance and auxiliary units are available to give your system vacuum interrupter and primary connection bars. Removed as
planning staff a wide range of latitude. These basic functions, a unit, it simplifies replacement of vacuum interrupters should
plus the versatility of two-high breaker stacking, afford maximum they have to be replaced.
value for your application dollar. Breaker mechanism is stored energy spring-charged providing
The modular design of Power/Vac metalclad switchgear com- fast closing and opening speeds. Parts are high quality
bines with precision tooled parts, computer-aided design and precision tooled to close tolerances for operating consistency,
advanced production techniques to set a new standard of excel- reliability, maintenance ease and long life.
lence exhibited in the superior reliability figures cited earlier. 4000 Amp is fan cooled.
Power/Vac Equipment
Ratings4.76 kV-20KA through 15 kV-63kA For more information on these products:
Two-high breaker stacking can save up to 50% in floor space Power/Vac Descriptive Brochure DEA-398
Power/Vac Application Guide GET-6600
depending on rating, and results in fewer shipping splits.
Power/Vac Switchgear Installation Manual GEK-39672
Main bus compartment is completely isolated by metal barriers. BreakMaster Medium Voltage Load Interrupter DEA-052
All main bus joints have tin plated connections for positive
contact and low resistance and are insulated with preformed
boots (silver plated optional). Bus bars are provided with high For pricing and application assistance,
contact your local GE sales office.
dielectric insulation; they pass through track resistant polyester
glass barriers between cubicles. Porcelain insulation to ground
is optional.
Rugged steel frame employs reinforced steel gussets for added
strength and dimensional integrity.
Breakers are directly racked into position on rails which ensure
proper alignment of primary and secondary connections.
Positive stops are provided in TEST/DISCONNECT and
CONNECT positions.
Precision tooling brings uniform quality to breaker and
equipment parts and facilitates trouble-free field assembly
and operation.
Auxiliary draw-out trays can be mounted above or below
breakers for greater flexibility.
Features
VB Power/Vac skeleton frame is designed for use by
OEM switchgear builders.
Paralleling Switchgear...............................................................19-2
Energy Commander................................................................................19-3
System Applications ...............................................................................19-5
Ordering Information .............................................................................19-6
Paralleling Switchgear Energy Commander has become the leader in supplying solutions
Paralleling is an operation in which multiple power sources, usu- to simple and very complex systems due to its design reliability,
ally two or more generator sets, are connected and synchronized flexibility, uninterruptible maintenance, and operative cost savings.
to a common bus (same parameters with respect to frequency, Energy Commander has evolved and adapted to the changing
phase angle, etc.). technologies in engine generator design, switchgear controls and
monitoring systems. It reflects GEs continuing commitment
to reliable solutions for critical power applications.
Why Paralleling Switchgear?
There are several advantages to be realized when employing
paralleling switchgear in an electrical design such as increased Designed to your specifications in a team effort
reliability, flexibility, ease of uninterruptible maintenance and Complex switchgear systems is where GE excels. With over 30
application/operation cost savings. It is because of these advan- years experience in all types of paralleling applications, our team
tages that paralleling switchgear has become one of the best of systems engineers will work with you to design a system that
choices for meeting todays power requirements. conforms to your exact facility needs. Whether low or medium
Reliability voltage, GE provides you with expert system layout, device
Systems in which part of the load is very critical may be best selection, construction, programming, monitoring, control, startup,
served by paralleling one or more generator sets. Under parallel training, and preventative maintenance services. We will work
operation all the generator sets are started at once. The first set to with you from project inception through commissioning and
reach the proper parameters will assume the most critical portion training to make certain that your project goes smoothly.
of the load, with the remaining sets picking up lower priority loads. Available for all types of systems including emergency power,
In addition, by using a load shedding application, the failure of one peak shave/utility rate incentive, cogeneration and prime power
generator set will not interrupt power to the critical loads, as and utilizing diesel or natural gas reciprocating engines, turbines,
lower priority loads can be dropped offline. fuel cells, multiple utility sources and other prime movers, Energy
Flexibility Commander is truly versatile. In all applications, the systems
Paralleling power sources allows for a wide variety of choices in use the latest technology in programmable control, high-speed
the generation, distribution and utilization of the systems power. networks, data acquisition and operator interface software
and hardware.
Uninterruptible Maintenance
When one engine - generator set is out of service for maintenance Energy Commander products offer designers and owners
or repair, having others synchronized on the same bus can provide an almost unlimited number of configurations and
the necessary back-up power, should an outage occur. operational parameters.
Cost Savings Designed to meet your requirements
Savings can be realized on the application when a number of Operator interface panel with touch screen for system control
smaller sets would be less expensive than one large set or when UL 891, UL 1558 and UL Medium Voltage switchgear
the load makes it impractical to divide into several sections, each listings available
with its own generator. Savings can also occur on the operation GE Intelligent Platforms PLC control and full range of GE
side when generator set life is extended from being used only components including protective relays, breakers, metering and
when needed to support the load. Also, when it is anticipated that monitoring devices, etc.
the load will grow significantly in the future, the capital investment Complete project design and approval drawings coordinated by
can be reduced by starting with small sets and paralleling our experienced project engineers
additional units as load increases dictate. Final instruction manuals including a drawing package that
shows part numbers on all devices, making it easier to order
spare parts and replacements
Why Energy Commander? To/from numbering on the wire ends for easy verification and
debugging
Energy Commander paralleling switchgear has been providing
Field startup and training of site personnel
customer facilities with reliable power switching systems for
Project management from pre-quote services to final
many years and continues its excellence into the 21st century.
acceptance
Since the inception of paralleling switchgear, many successful
Preventative maintenance services
Energy Commander installations have been supplied with a focus
on providing reliability.
System Reliability
The Energy Commander Paralleling Switchgear product has sev-
eral hardwired features which ensures trouble-free operation and
maximum reliability. Annunciator panels, load control switches
and meters are all hardwired components. Upon the unlikely
failure of the master control, a back-up engine start operation is
hardwired into the system. Also the programmable logic controller
(PLC) which runs automatic operations is backed up with a true
hardwired manual control.
Finally, as a leader of paralleling switchgear technology, Energy
Commander has an extensive array of successful, trouble-free
installations around the globe. The breadth of experience and
system complexity all make Energy Commander second to none
in the industry.
System Applications
Prime Power
Features
On-site prime power systems are most often used where there
is no utility source available.
The required electricity is generated entirely on-site, typically Generator Generator
at facilities such as island resorts, mines, mills or other
remote locations.
Since utility is not available in prime power systems, ATSs/ATOs
and utility/tie breakers are not required.
Components
Generators are the only source of power. The system typically
consists of PSG product with no ATS/ATO products.
Load Load
System Applications
Exhaust
Feeders
Paralleling Switchgear
Power Quality Services ..............................................................20-2 Digital Energy LP33U Series 208 V (Three-Phase 10-100 kVA)
Digital Energy VCL Series.......................................................20-4 Description, Features and Benefits...............................................20-24
Digital Energy VH Series (700-2000 Rackmount and/or Tower) Technical Specifications and Dimensions .................................20-25
Description, Applications, Features and Benefits .....................20-5 Product Tables UPS and Battery Cabinets.............................20-26
Technical Specifications and Dimensions....................................20-6 Digital Energy SG Series 480 V (Three-Phase 10-750 kVA)
Product Tables UPS and Battery Packs......................................20-7 Description, Features and Benefits...............................................20-31
Digital Energy GT Series 120 V (3000 VA Tower) Technical Specifications and Dimensions (10-150 kVA)......20-33
Description, Applications, Features and Benefits...................20-10 Product Tables (10-150 kVA) UPS, Battery Cabinets,
Technical Specifications and Dimensions .................................20-11 Transformers and Bypass Panels...............................................20-33
Product Tables UPS...........................................................................20-11 Technical Specifications and Dimensions (225-300 kVA) ...20-40
Digital Energy GT Series 120 V (3000 19" Rackmount) Product Tables (225-300 kVA) ) UPS, Battery Cabinets,
Description, Applications, Features and Benefits...................20-12 Transformers and Bypass Panels..............................................20-40
Technical Specifications and Dimensions .................................20-13 Technical Specifications and Dimensions (400-500 kVA)......20-43
Product Tables UPS and Battery Packs...................................20-13 Product Tables (400-500 kVA) UPS, Battery Cabinets,
Digital Energy GT Series (5kVA and 6kVA Tower/Rackmount) Transformers and Bypass Panels..............................................20-43
Description, Features and Benefits...............................................20-14 Software and Connectivity Products (10-500 kVA) ................20-45
Technical Specifications and Dimensions .................................20-15 Spare Parts, Options and Accessories (10-500 kVA) .............20-46
Product Tables UPS and Battery Packs...................................20-16 Services and Commissioning (10-500 kVA)...............................20-47
Digital Energy GT Series (8kVA and 10kVA Tower/Rackmount) Digital Energy TLE Series (225-1500 kW)
Description, Features and Benefits...............................................20-17 Description, Features and Benefits...............................................20-48
Technical Specifications and Dimensions .................................20-18
Product Tables UPS and Battery Packs...................................20-19
Digital Energy LP11U Series 208 V (Single-Phase 5-10 kVA)
Description, Features and Benefits...............................................20-20
Technical Specifications and Dimensions .................................20-21
Product Tables UPS and Battery Packs...................................20-22
GEs new line interactive pluggable range of UPS, the VCL Series UL,
is available in tower and/or rack format, 2U high across all ratings.
The UPS is a high performance range available in 800VA, 1100VA,
2000VA and 3000VA.
Please contact your sales representative or refer to the website for
further details.
Description
GEs VH Series Uninterruptible Power Supply (UPS) connects be-
tween the utility and your critical load, helping ensure that when
the utility drops or fails, your load continues to receive a clean,
constant and reliable power supply. The VH Series UPS is ideal for
protection against utility variances and failures for PC, telecom,
laboratory, industrial and critical process loads.
The VH Series is a true Voltage and Frequency Independent (VFI)
on line, double conversion UPS providing secure power for busi-
ness-critical applications. With a tower and/or rack mount design,
the UPS adapts to adjusting network configurations as facility
load requirements change. Delivering 0.9 output power factor, a
Mean Time Between Failure (MTBF) of 730,000 hours and a three
year warranty standard on UPS and battery, the user can be as-
sured of a high performance, high power and highly reliable level
of power protection.
Battery charger
Battery charging characteristic Constant current charging until boost voltage, then float voltage charging
AC input voltage range 60 to 140V
DC output voltage Vdc 40.5 81
Output current limitation Adc 1.5
Recharge time 3 hours for 90% capacity, standard battery
Battery data
Battery type Sealed lead acid, VRLA
Float voltage at 25C Vdc 40.5 81
Number & rating of 12V batteries (standard version) 3*7Ah 3*9Ah 6*7Ah 6*9Ah
Standard backup time at nominal resistive load min 8 8 7.2 8
End of discharging voltage (Vdc/cell) Vdc 1.66
Standard backup extensions (Table.1 for backup time) NO YES YES YES
Bypass
Primary Element Static switch
Bypass voltage limits -15% to +10% of selected output voltage
Frequency tracking range 10% default ( 2% selectable) of selected output frequency
Slew rate 2 Hz/sec
Overload capability on bypass 120% 3min. 150% 1 min
Interfacing
Potential free contacts (optional) Four change-over contacts signalling following alarms:
- bypass active
- mains failure
- battery low
- general alarm (programmable)
Input terminals for - Remote Power Off
- Battery extension pack DC connector
Note: all indicated values are typical. Variations may be found from one unit to another.
Description
The Digital Energy GT Series Tower UPS provides high quality
power protection in a cost effective package. The GT Series is a
compact, true VFI (Voltage and Frequency Independent) on-line
double conversion high performance device.
The UPS is designed to support and protect mission-critical
applications, and the bypass mode provides high reliability
against mains power disturbances. All GT Series UPSs are micro-
processor controlled and equipped with RS232 communication
and optional SNMP interfacing capabilities for all major operating
systems, with optional battery pack extended runtime options
also available.
On line double conversion technology eliminates power
reliability problems
High visibility graphic display gives the user immediate view of
UPS status
Automatic internal bypass
Programmable switch-off for less critical loads to maximize
up-time of critical devices. (load shedding)
Modern design fits well into an office environment
Applications
Mission Critical Servers
Medical Equipment
ATM / Frame Relay Switches
Banking Systems
Telecoms / PABX
Features and Benefits
High input power factor (>.97) and low input distortion prevents
disturbances to other electrical equipment, thus eliminating the
need for costly filters or over- sized feeders
Compact footprint, easily transportable, robustly designed
system with low audible noise suitable for both office and
industrial environments
Utilizes high-frequency PWM (Pulse Width Modulation) digital
control technique resulting in extremely low output distortion
and fast transient response eliminating the need for over-sizing
the UPS
Robustly designed to handle short-circuit, high overload and
over-heating conditions, thus reducing maintenance and
service costs
GT Series High Crest Factor (3:1) capability makes it ideal for
computer loads while eliminating the need to oversize the UPS
Very wide AC-input voltage capability minimizes the need to
switch to batteries which results in increased battery life
Fully compliant with UL1778 and CSA 22.2-107 standards for
VFI operation providing full power protection for demanding
critical applications
Every GE UPS can be monitored and managed via LAN and
serial connection
UPS management software facilitating operation and
maintenance of the UPS
Available slot for SNMP plug-in card, potential-free relay
contacts, and RS232/contact interface providing maximum
flexibility
Description
The Digital Energy GT Series Rackmount UPS provides a high
quality power protection in a cost effective manner. The GT Series
is a true VFI (Voltage and Frequency Independent) On-line double
conversion high performance device.
The UPS is designed to support and protect mission-critical
applications, and the bypass mode provides high reliability
against mains power disturbances. All GE Digital Energy GT
UPSs are microprocessor controlled and equipped with RS232
communication and optional SNMP interfacing capabilities for all
major operating systems, with extended optional battery pack
runtime options available.
The GT Series is designed especially for typical rack mount
demands, including long backup times and high ambient temper-
atures, but can be a stand-alone unit for increased versatility.
Online double conversion technology eliminates power Features and Benefits
reliability problems High input power factor (>.97) and low input distortion prevents
Rack design provides application versatility disturbances to other electrical equipment, thus eliminating the
Rack height maximizes rack space need for costly filters or oversized feeders
Online double conversion technology eliminates power Compact footprint, easily transportable, robustly designed
reliability problems system with low audible noise suitable for both office and indus-
Easy plug-in connection of battery packs for extended runtime trial environments
Simple to install and operate Utilizes high-frequency PWM (Pulse Width Modulation) digital
Automatic internal bypass control technique resulting in extremely low output distortion
Programmable switch-off for less critical loads to maximize up- and fast transient response eliminating the need for oversizing
time of critical devices (load shedding) the UPS
Robustly designed to handle short-circuit, high overload and
Applications
over-heating conditions, thus reducing maintenance and
PC and Server Networks service costs
EPOS GT Series High Crest Factor (3:1) capability makes it ideal for
Network Components (Routers, Hubs) computer loads while eliminating the need to oversize the UPS
Security Systems Very wide AC-input voltage capability minimizes the need to
Process Control switch to batteries which results in increased battery life
Fully compliant with international standards for VFI (IEC 62040-3)
operation providing full power protection for demanding
critical applications
UPS management software facilitating operation and
maintenance of the UPS
Available slot for SNMP plug-in card, potential-free relay contacts,
and RS232/contact interface providing maximum flexibility
Description
With the Digital Energy GT Series, your equipment is protected
from any uctuation in your power source, enabling you to con-
centrate on your core activities. The GT Series is a true VFI (Voltage
& Frequency Independent) on-line double conversion, trans-
formerless, intelligent and high performance UPS.
This UPS provides critical power protection to suit a wide range of
IT Networks, Telecom and other applications. The GT Series is easy
to install and service, and is designed for maximum site exibility.
With an attractively designed modern common tower and/or
19-inch rack mount cabinet, the UPS can adapt as network
congurations adapt.
For communication, the GT series is equipped with RS232 and
contact interface as standard; a web-enabled SNMP card is
available as an option. Operation from remote or unmanned sites
is simple to coordinate with standard remote monitoring function- Applications
ality. No load shutdown, automatic frequency detection, settable Computer and data centers
minimum start-up runtime and extended runtime availability Call centers
with optional battery packs are additional features of the Telecommunications equipment
GT Series UPS. Security systems
Financial institutions
Performance Features
Fixed and mobile voice and data transmission
Rack / Tower Mounting
Auto Sensing 50/60Hz Vertical Markets
Extended Runtime options - Additional Runtime with 2U plug & Healthcare
play Battery Packs Education
Additional Communications SNMP Card Slot Retail
Included Monitoring & Operational Software Entertainment
Built in RS232 Communication port Telecom
Emergency Power Off Terminal Connections for EPO Financial
User Replaceable Hot Swappable Batteries Broadcasting
Standard 2 year warranty
Wide Input Voltage window
Internal Auto and Manual Bypass
Modular PDU Plugs for Single-Phase UPS Tower / Rackmount - 5.0kVA and 6.0kVA
Outlets (NEMA) Input (NEMA)
5-20R T L5-20R L5-30R EN60320 L6-20R L6-30R L14-30R L14-30R
TB2 TB2
Product Number L1-N-G L2-N-G L1-N-G L2-N-G L1-N-G L2-N-G L1-N-G L2-N-G L1-L2-G L1-L2-G L1-N-L2-G
UPS10206211 1 - - - - - - - - - - - 1 -
UPS1020622 1 - - - - - - - - - - - 1 -
UPS1020623 - 2 2 - - - - - - - 1 1 - 1
UPS1020624 - 1 1 - - - - - - 2 - - - 1
UPS1020625 - 2 2 - - - - - - - 2 - - 1
UPS1020626 - - - - - - - 2 2 - - - - 1
UPS1020627 - - - 2 2 1 1 - - - - - - 1
UPS1020628 - - - 2 2 - - - - - 2 - - 1
UPS1020629 - - - - - - - - - 4 - - - 1
1No 3 pole 6 ms maximum transfer time manual bypass.
2 TB = Terminal Block
NOTES:
a PDU is required for each 5 or 6 kVA unit - PDUs are replaceable and interchangeable within unit grouping
Internal Battery module (s) will be shipped in a separate box
Description
With the Digital Energy GT Series, your mission- critical equipment
is protected from any uctuation in your power source, enabling
you to concentrate on your core activities. The GT Series is a true
VFI (Voltage & Frequency Independent) on-line double conversion,
transformerless, intelligent and high performance UPS.
This UPS provides critical power protection to suit a wide range of
IT Networks, Telecom and other applications. The GT Series is easy
to install and service, and is designed for maximum site exibil-
ity. With an attractively designed modern common tower and/or
19-inch rack mount cabinet, the UPS can adapt as network
congurations adapt.
Both the power and redundancy of the system can be expanded
by adding units (N+2) to create a parallel system. For communica-
tion, the GT series is equipped with RS232 and contact interface Applications
as standard; a web-enabled SNMP card is available as an option. Computer and data centers
Operation from remote or unmanned sites is simple to coordinate Call centers
with standard remote monitoring functionality. No load shutdown, Telecommunications equipment
automatic frequency detection, settable minimum start-up run- Security systems
time and extended runtime availability with optional battery packs Financial institutions
are additional features of the GT Series UPS. Fixed and mobile voice and data transmission
Performance Features Vertical Markets
Rack / Tower Mounting Healthcare
Auto sensing 50/60Hz Education
Extended Runtime options - Additional Runtime with 2U plug & Retail
play Battery Packs Entertainment
Additional Communications SNMP Card Slot Telecom
Included Monitoring & Operational Software Financial
Built in RS232 Communication Port Broadcasting
Internal/Automatic and manual bypass
User Replaceable Hot Swappable Batteries
User Replaceable Hot Swappable Power Unit
Standard 2 year warranty
Parallel N+2 or N+1 redundancy
Modular PDU Plugs for Single-Phase UPS Tower / Rackmount - 8.0kVA and 10.0kVA
Outlets (NEMA)
Product Number 5-20R T L5-20R L6-20R L6-30R
L1-N-G L2-N-G L1-N-G L2-N-G L1-L2-G L1-L2-G
UPS1020660 4 4 - - - 2
UPS1020661 2 2 - - 4 -
UPS1020662 2 2 - - - 4
UPS1020663 2 2 - - 2 2
UPS1020664 2 2 1 1 - 2
UPS1020665 - - 2 2 4 -
Dimensions (in/cm)
Height Width Depth
Enclosure A 26.8 (68) 12.3 (31.2) 28.7 (72.9)
Enclosure B 39.2 (99.6) 12.3 (31.2) 28.7 (72.9)
Input Options2
UPS Rating: 5kVA 6kVA 8kVA 10kVA
P/N Description (choose 1) Input V: 120V 208V 240V 120V 208V 240V 120V 208V 240V 120V 208V 240V
I000 208/240V Input, No Input Cord x x x x x x x x
I001 120V Input, No Input Cord x x x x
I002 208/240V Input, 10/3 Input Cord & L6-30P Plug x x
I003 208/240V Input, 8/3 Input Cord & 6-50P Plug x x x x x x
I004 120V Input, 8/3 Input Cord & 5-50P Plug x
Output Options
UPS Rating: 5kVA 6kVA 8kVA 10kVA
P/N Description (choose 3) Output V: 120V 208V 240V 120V 208V 240V 120V 208V 240V 120V 208V 240V
0 Blank Cover Plate - Req'd for unused spaces x x x x x x x x x x x x
1 5-20 Duplex, 120V, 20A (L-N-G) x x x x x x x x x x x x
2 L5-15R, 120V, 15A (L-N-G) x x x x x x x x x x x x
3 L5-20R, 120V, 20A (L-N-G) x x x x x x x x x x x x
4 L5-30R, 120V, 30A (L-N-G) x x x x x x x x x x x x
5 L6-15R, 208/240V, 15A (L1-L2-G) x x x x x x x x
6 L6-20R, 208/240V, 20A (L1-L2-G) x x x x x x x x
8 L6-30R, 208/240V, 30A (L1-L2-G) x x x x x x x x
A 5-50R, 120V, 50A (L-N-G) x x x x x x x
B L14-20R, 208/240V, 20A (L1-N-L2-G) x x x x x x x x
C L14-30R, 208/240V, 30A (L1-N-L2-G) x x x x x x x
Installation Options
P/N Description (choose 1)
IA Factory Installed
RA Field Installed2
"xxx" in the Product Number represents the UPS module kVA rating: '010' for 10kVA, '225' for 225kVA, etc.
"z" in the Product Number represents the total number of UPS modules in RPA systems.
UPS Commissioning by a GE-authorized Service Technician is required to initiate warranty coverage.
All equipment installation must be completed prior to commissioning (see Startup Checklist)
and must be scheduled two weeks in advance.
All run times listed above are based on the manufacturers published data, and do not include connector and wiring losses.
These run times are approxmate and are intended for use as a guide only. Consult factory for guarranteed run times.
All cabinets contain Flame Retardant Batteries.
288 Vdc Nominal - 144 cells - 1.67 Final Volts per Cell, except 1.75 Final Volts per Cell over 60 minutes.
Includes internally mounted circuit breaker(s) sized for the UPS at 100% load. See "Breaker Configuration" column in table above.
Each string, in multi-string systems, is individually fused.
An external, user supplied junction panel is required when multiple battery systems are to be connected to a single UPS.
These cabinets utilize batteries manufactured by Power Battery Company, Inc. and carry a standard 10-year, pro-rated warranty. (Labor and freight not included.)
Optional 5-year, full replacement warranty does not include labor of freight. Total warranty period is 5-years.
80 kVA -External Wall Mounted Maintenance Bypass System - 3 Breaker MBP - Recommended Configuration
SKRU UIB- Dimensions Weight
Kirk-key MIB/MBB kAIC Rating (H x W x D - in.) Lbs. Product Number
Yes 350A/300A 65 30 x 11 x 42 125 MBP082-303500-K600
100 kVA -External Maintenance Bypass System - 3 Breaker MBP - Recommended Configuration
SKRU UIB- Dimensions Weight
Kirk-key MIB/MBB kAIC Rating (H x W x D - in.) Lbs. Product Number
Yes 400A/350A 65 30 x 11 x 42 125 MBP102-354000-K600
80 kVA and 100kVA UPS Input Transformer Non k-Rated, Aluminum non-matching, NEMA 1 Enclosure
Transformer Voltages kVA Dimensions Weight
Location Primary - Secondary Rating (H x W x D - in.) Lbs. Product Number
Input 480V- 208/120V 150 35 x 24 x 46 775 U9T83B3876
SG Software/Monitoring
Description Product Number
Advanced SNMP/Web interface card, UTP/BNC UPS11701
Remote Status Panel (includes APS) UPS11785
Customer Interface Card (CIC) - six programmable relay contacts UPS1006691
External SNMP Interface Box (requires LincBox Protocol Converter) UPS1009223
LincBox (CP4) Protocol Converter (uses RS-232 connection to UPS) UPS11483
Modbus RTU RS232 UPS16276
Modbus RTU RS485 UPS16275
RS232 to RS485/422 Converter UPS11227
Hardware
Description Product Number
Intelligent Sync Module
This module sync's two parallel systems together to allow the outputs to switch in-Phase with a static switch. UPS16274
IRIS Services
Description Product Number
IRIS starter kit for LanPro1 IRLP
IRIS starter kit for SP/SG/LP33U S/P 10-40kVA1 IRSP04
IRIS starter kit for SP/SG/LP33U S/P 60-120kVA1 IRSP12
IRIS starter kit for SP/SG/LP33U S/P 150-550kVA1 IRSP50
IRIS yearly fee after 1st year for LP11U2 FIRLP
IRIS yearly fee after 1st year for SP/SG/LP33U S/P 10-40kVA2 FIRSP04
IRIS yearly fee after 1st year for SP/SG/LP33U S/P 60-120kVA2 FIRSP12
IRIS yearly fee after 1st year for SP/SG/LP33U S/P 150-500kVA2 FIRSP50
Additional IRIS Fees
LincBox (CP4) Protocol Converter w/cables UPS11483
IRIS end user license per year incl. 1 password, email, fax or pager address LIREU01
IRIS additional Pager, FAX or email address, prices per message for each individual address AIR01
IRIS manual refresh UPS status (price per refresh/per UPS) RIR01
1Includes Lincbox
2Does not include Lincbox
"xxx" in the Product Number represents the UPS module kVA rating: '010' for 10kVA, '225' for 225kVA, etc.
"z" in the Product Number represents the total number of UPS modules in RPA systems.
UPS Commissioning by a GE-authorized Service Technician is required to initiate warranty coverage.
All equipment installation must be completed prior to commissioning (see Startup Checklist) and must be scheduled two weeks in advance.
The TLE Series UPS is one of the best performing three-phase UPS
systems providing critical power protection for a wide range of
applications. The TLE Series operates in VFI mode (Voltage
Frequency Independent) and has been developed to satisfy the
growing request of high efficiency through an innovative control
algorithm with 3-level inverter technology. This innovative product
provides best-in-class efficiency in double conversion mode as
well as eBoost operating mode. The TLE Series is developed
using GEs Design for Six Sigma methodology to help ensure that
the product fully meets customer requirements and expectations.
The TLE Series UPS provides industry-leading reliability, efficiency,
clean input performance and unity power factor at output.
Reliability can be further increased by paralleling more units
utilizing GEs unique RPA (Redundant Parallel Architecture)
technology. Through their complete life cycle, all GE UPS
systems are fully supported by service teams which provide
world-class, 24x7 preventive and corrective services, training
and application expertise.
Introduction.................................................................................21-1
Fiber Closure Hardware ............................................................21-2
Cable Location Surge Protectors.............................................21-4
Introduction
GE has been manufacturing Telecommunication Hardware
products for over 20 years and has become a leader in providing
custom solutions in surge and filter protection and fiber closure
systems.
Specifications
710 - 4" (102mm) x 21" (533mm)
711 - 4" (102mm) x 25" (635mm)
Hold 2 splice trays
Accommodate 1-30 spliced fibers
Accept cables up to 7/8" in diameter
720 - 6" (152mm) x 28" (711mm)
725 - 6" (152mm) x 32" (813mm)
Hold 6 or 8 splice trays
Accommodate 1-216 spliced fibers
Accept cables up to 1" in diameter
730/732- 8" (203mm) x 32" (813mm)
Hold up to 12 splice trays
Accommodate 1-432 spliced fibers
Accept cables up to 1 1/4" in diameter
Material
Cylindrical Housing - Rigid, non-corrosive,
high impact extruded plastic.
Inner Parts
Non corrosive metallic materials.
Each splice closure comes equipped with
cable pull brackets.
710/711 720-08 720-28 730/732 Cylindrical
Shipping Weight:
Housing
710 8lbs. (3.6kg)
720 17lbs. (7.7kg)
732 34lbs. (15.4kg)
OPGW Closures Closures equipped with Surge Protectors - Patent#: 5,652,820
The GE Fiber 705-XXX OPGW frame is designed for splicing and By integrating the Fiber Cable Protector with the Fiber Closure
terminating OPGW fiber cables. The frame provides an interface System, the installation of a Fiber Cable Locating System is
between the standard GE fiber optic splice closure and the OPGW simplified. The cable protector is preinstalled and tested with the
cable. Aluminum clamping plates mounted to the frame provide fiber closure, splice trays, ground lugs and ground wires. Each
the pull-out strength required for the heavy cables, isolating the system is also equipped with mounting brackets for both man-
stress away from the closure. The splice closures mount to the hole and aerial installations. This system saves many installation
frame with a standard pole mount bracket, allowing easy assem- hours and minimizes installation errors in the field.
bly and quick re-entry to the closure. The unique feature of this product is its capability to protect
The GE OPGW frame accommodates the 4" diameter 710-03, the multiple fiber optic cables while allowing the cables to be
6" diameter 720-08, and the 8" diameter 730-05 fiber optic splice remotely located from one source.
closures. This provides the installer the option to purchase a small- Cable locating and surge protection integrated into
er, more economical closure when installing low fiber count OPGW closure system.
cables. The large 730-05 closure can be used when installing high Multiple cable capability. (backbone plus 4 branch)
fiber count OPGW cables. Each of the above closures will accom- Initial cost savings.
modate splicing OPGW cables to OPGW cables or OPGW cables to Cut installation time.
dielectric cables. The larger closures (720-08 and 730-05) will each Eliminate extra hand hold.
accept up to four OPGW cables and two dielectric cables at a Convenient access.
time. Cable clamps are available to accommodate OPGW cables Available with 6" or 8" closures.
with outside diameters ranging from .465" to .646".
For special applications, the GE OPGW frame can be mounted
inside the 705002008 galvanized steel canister. This canister pro-
vides a bullet resistant shell to protect the fiber optic splice closure.
City Ring
444 (end)
LMS
444 (intermediate)
LMS & 445X
(switch)
445X 444
(farthest point
from switch box)
444 444
444
444 444
444
Point to Point
GE 442
LMS 445X
GE 444
GE 445X
444
444
444
NOTES:
With our global brands of Multilin, MDS, Lentronics and ITI, GE For more information on these products, please visit our website
Digital Energy designs, manufactures, distributes and supports a at www.gedigitalenergy.com or contact your local sales
full range of protection, control, metering, telecommunications representative. GE Digital Energy provides worldwide customer
and power sensing equipment, software and services for indus- support 24/7 for its products and systems through its Customer
trial, utility and transportation customers. Support Centers.
The Multilin line of protection and control products are based on Contact us directly:
industry leading technologies essential for the reliable operation North America / Worldwide Europe / Middle East / Africa
of mission-critical applications including generation, transmission, 215 Anderson Ave. Avenida Pinoa 10-48170
distribution, metering, motors, and communications. Multilin pro- Markham, Ontario Zamudio (Vizcaya), Spain
tection relays and systems are complemented with a complete Canada L6E 1B3 Tel.: +34 94 485 88 00
line of substation hardened multiplexers, Ethernet switch network Toll Free (NA Only): Fax: +34 94 485 88 45
devices, and wireless radios for utility teleprotection, industrial, 1-800-547-8629 E-mail: gemultilin.euro@ge.com
transit, railways, and highway traffic management systems. Every Tel.: 905-294-6222
aspect of device configuration and monitoring is made simple Fax: 905-201-2098
through the powerful EnerVista suite of software tools. All relays E-mail: gemultilin@ge.com
are programmed and managed through EnerVista Software.
The GE Digital Energy ITI brand of power sensing products Asia
include a full line of current, voltage and potential transformers, Floor 22-24, No 900 Yishan Rd.
switches, indicating lights and other protection relay accessories. Scientific Building C
Complimenting our products, we also offer a complete range of Shanghai, China 200233
consulting services, customized panel solutions and fully inte- Tel.: +86 21 2401 3208
grated energy management systems for effective energy savings. Fax: +86 21 5423 5080
Specialized Protection, Control and Recording.................22-110 Media & Protocol Converters ...............................................22-187
C60 Breaker Monitoring and Control........................................22-111 MultiNet RS485 to Ethernet ........................................................22-188
C30 I/O Logic Controller..................................................................22-113 Media & Protocol Converters........................................................22-189
N60 Network Stability and Synchrophasor Measurement .....22-115 Power Sensing
C70 Capacitor Bank Protection...................................................22-117 Instrument Transformers .....................................................22-190
C90Plus Automation Control System...........................................22-119 Current Transformers ......................................................................22-190
HardFiber 61850 Process Bus......................................................22-121 Low Voltage Potential Transformers ........................................22-193
MIV II Voltage/Frequency Protection........................................22-123 Bushing Current Transformers....................................................22-194
MIN II Ground Protection................................................................22-124 Medium Voltage Instrument Transformers ...........................22-194
RRTD Remote RTD Metering Module for the 369 ................22-125 Control Power Transformers ........................................................22-195
DDFR Distributed Digital Fault Recorder.................................22-126 Current Transducers.........................................................................22-195
Single Function Protection Relays.......................................22-128 IEC Rated Instrument Transformers .........................................22-196
Single Function Auxiliary Relays..........................................22-138 Accessories ..............................................................................22-197
Substation Gateways and RTU.............................................22-140 Switches
D400 Advanced Substation Gateway ......................................22-140 SB-1, SB-9, Series 95.........................................................................22-197
D20MX Substation Controller.......................................................22-142 SB-10, SBM, FT, RT Test Switch ....................................................22-198
D.20 RIO Distributed I/O Controller............................................22-144 Test Equipment
D25 Substation Controller .............................................................22-145 515, PK2, XCA, XLA.............................................................................22-199
Metering Terminal Blocks
Digital Metering ......................................................................22-147 116B407, EB-25, EB-26, EB-27, IKU, EB-1, EB-2, EB-4.......22-199
Digital Metering Family Selection Guide .................................22-148 Indicator Lights
PQM II Power Quality Meter ..........................................................22-149 ET-16, ET-16 LED, ET-17..................................................................22-199
EPM 9900 Advanced Power Quality Meter ............................22-150 Test Equipment
EPM 9800 Socket Mounted Power Quality Meter ...............22-152 RTT Desktop Test Set ........................................................................22-200
EPM 9000 Advanced Power Quality Meter ............................22-154 Software
EPM 7000 Revenue Class PQ Meter ..........................................22-156 EnerVista Suite......................................................................22-202
EPM 6010 Building Automation Meter .....................................22-158 Launchpad Device Setup & Document Management .....22-203
EPM 6000 Revenue Class Power Meter ...................................22-159 Viewpoint Engineer Control Logic Creator &
EPM 2200 Power Meter ...................................................................22-160 Commissioning Toolset ...................................................................22-206
EPM 4500 Multi-tenant Sub-Metering System.....................22-161 Viewpoint Maintenance Device Health &
EPM 1500 Single-point Sub-Metering System .....................22-164 Security Reporting.............................................................................22-210
EPM 7100 Energy Submeter w/WIFI and Logging .............22-166 Viewpoint Monitoring & Data Recording ................................22-214
EPM 6100 Energy Submeter w/WIFI .........................................22-167 Integrator OPC/DDE Communications Server .....................22-224
GE Meter in a Box (MIB) ...................................................................22-168 Value Added Services
Communications Value Added Services.............................................................22-227
Multiplexers .............................................................................22-170 Energy Management Systems.....................................................22-227
Multiplexer Family Overview ........................................................22-171 Advanced Training Services..........................................................22-229
JMUX SONET Multiplexer................................................................22-174 Consulting Services...........................................................................22-231
JMUX T1 Multiplexer .........................................................................22-174 Packaged Solutions ..........................................................................22-233
TN1U SDH Multiplexer .....................................................................22-175 Product Upgrades And Replacements
TN1Ue SDH Enhanced Multiplexer ............................................22-175 Product Upgrades and Replacements................................22-234
VistaNET Network Management Software .........................22-176
MDS Wireless Solutions...................................................................22-178
Ethernet Switches...................................................................22-181
Multilink Family Overview ..............................................................22-181
ML3000 19 Rack-mounted Managed Switch......................22-182
ML2400 19 Rack-mounted Managed Switch......................22-184
ML1600 9 Panel-mounted Managed Switch.......................22-185
ML600 Unmanaged Compact Switch ......................................22-186
Features ANSI B30 B90 B95Plus C30 C60 C70 C90Plus D30
Protection
1. Disturbance Detector
2. Mho Distance, Phase (No. of Zones) 21P 5
3. Mho Distance, Ground or Neutral Phase (No. of Zones) 21G/N 3
4. Quadrilateral Distance, Phase (No. of Zones) 21P 3
5. Quadrilateral Distance, Ground or Neutral (No. of Zones) 21G/N 3
6. Permissive Pilot Logic
7. Sub-Cycle Distance
8. Overexcitation Protection (V/Hz) 24
9. Synchronism Check or Synchronizing 25
10. Undervoltage, Phase 27P
11. Undervoltage, Auxiliary 27X
12. Stator Ground (3rd Harmonic) 27TN
13. Sensitive Directional Power 32S
14. Loss of Excitation Based on Reactive Power 40Q
15. Loss of Excitation Based on Impedance Element 40
16. Current Unbalance 46
17. Broken Conductor Detection 46BC
18. IOC, Negative Sequence 46/50
19. TOC, Negative Sequence 46/51
20. Current Directional, Negative Sequence 46/67
21. Reverse Phase Sequence Voltage 47
22. Thermal Model 49
23. Inadvertent/Accidental Energization 50/27
24. End of Fault Protection
25. Motor Mechanical Jam
26. Motor Start Supervision
27. Motor Acceleration Time
28. User Programmable Curves
29. Breaker Failure 50BF Logic
30. IOC, Phase 50P
31. IOC, Ground 50G
32. IOC, Neutral 50N
33. IOC, Sensitive Ground 50SG
34. High Impedance Fault Detection
35. TOC, Phase 51P
36. TOC, Ground 51G
37. TOC, Neutral 51N
38. TOC, Sensitive Ground 51SG
39. TOC, Voltage Restrained 51V
40. Overvoltage, Phase 59P
41. Overvoltage, Auxiliary 59A
42. Overvoltage, Neutral 59N
43. Negative Sequence Overvoltage 59-2
44. 100% Stator Ground Protection 64TN
45. Current Directional, Phase 67P
46. Current Directional, Neutral 67N
47. Current Directional, Negative Sequence 46/67
48. Power Swing Blocking 68
49. Out-of-Step Tripping 78
50. AC Reclosing (No. of Shots) 79 4 4
51. Switch on to Fault (Line Pickup) SOTF
52. Voltage Transformer Fuse Failure VTFF
53. Current Transformer Supervision 50/74
54. Load Encroachment Logic
55. Underfrequency 81U
56. Overfrequency 810
57. Anti-Islanding Protection/Frequency Rate of Change 81R
58. Lockout Functionality 86
59. Bus Differential 87B
60. Line Current Differential 87L
61. Ground Differential 87G
62. Stator Differential 87S
63. Group Differential 87T
64. Line Phase Comparison 87PC
65. Voltage Differential
66. Capacitor Bank Overvoltage
67. Neutral Voltage Unbalance
68. Automatic Voltage Regulation
69. Time of Day Control
70. Instantaneous Differential 50/87
71. Split Phase Protection
72. Line Current Differential Trip Logic
73. CT Failure
D60 D90Plus F35 F60 G30 G60 L30 L60 L90 M60 N60 T35 T60
5 5 3 3 5 5
5 5 3 3 3
5 5 3 3 3
5 5 3 3 3
Logic Logic Logic Logic Logic
4 4 4 4 4 4
Key Benefits
Large backlit display with 40 characters to view relay
information and settings in direct sunlight, full numerical
keypad, and setpoint navigation keys. (Except 735/737)
Accurate metering under severe system disturbances (750, 745
& 489) - Power system frequency tracking and adjusting
sampling rate accordingly
Minimize replacement time - Draw-out construction
Improve uptime of auxiliary equipment - Through I/O monitoring
Ease of use and installation - same front panel programming,
common cutout (Except 735/737)
Reduce troubleshooting time and maintenance costs -IRIG-B
time synchronization, event reports, waveform capture, data
logger (Except 735/737)
Simplify testing - Built in simulation features and unique
waveform play back functionality in the 745
Cost Effective Access information - Via Modbus RTU and DNP 3.0
Level 2 protocols, through standard RS232, RS485 & RS422 serial
ports, and optional Modbus RTU over TCP/IP through embedded
Ethernet Port to connect to 10MB Ethernet local or wide area
networks.
Complete asset monitoring - Analog I/O, metering including
Features (continued)
demand & energy (Except 735/737)
Follow technology evolution - Flash memory for product User Interface and Programming
field upgrade (Except 735/737 that requires an EEPROM Front Panel LEDs, full key pad, and backlit LCD display
replacement) RS232, RS485 and RS422 ports - up to 19,200 bps
Long lasting life - When exposed to chemically corrosive and Ethernet port - 10 Mbs
humid environments with optional conformal coating Multiple protocols - ModBus RTU, ModBus RTU over TCP/IP,
(Except 735/737) DNP 3.0 Level 2, Optional Device Net on 469
EnerVista Software
State of the art software for configuration and commissioning
Applications GE Multilin products
735/737 - Feeder Protection Document and software archiving toolset to ensure reference
750/760 - Feeder Protection (comprehensive) material and device utilities are up-to-date
469 - Motor Protection EnerVista Integrator providing easy integration of data
745 - Transformer Protection in the SR relays into new or existing monitoring and
489 - Generator Protection control systems
Features
Monitoring and Metering
Event recorder
Oscillography and Data Logger
Self diagnostic
Metering
Demand
Key Benefits
Unique built-in control features - Comprehensive protection plus
programmable logic
Flexible and cost effective control for complex systems - Use IEC
compatible programmable logic to customize the functionality
of your protection & control system to address unique, site
specific applications
Human machine interface (HMI) - Standard backlit LCD display
with 4 x 20, optional 16 x 40 (240 x 128 pixels) graphical LCD,
programmable buttons, and rotary knob for selecting setting
menus, and submenus.
Minimize replacement time - Modular with card
draw-out construction
Reduce troubleshooting time and maintenance costs -
IRIG-B time synchronization, event reports, waveform capture,
data logger
Cost Effective Access information - Via multiple protocols,
through standard RS232, & RS485, Ethernet Ports.
Optimal integration flexibility via open standard protocols - Mod-
bus RTU, DNP 3.0 Level 2, IEC60870-5-104, IEC61850
Minimize communication down time - Reliable redundant
Ethernet Communication ports with 10/100BaseTX, 100BaseFX
with ST connectors, and optional double 100BaseFX, with
ST connectors Features (continued)
Complete asset monitoring - Full metering including demand Monitoring and Metering
& energy Energy metering
Follow technology evolution - Flash memory for product Demand metering
field upgrade Trip circuit monitoring
Oscillography
Applications Data logger
Sequence of event
F650: Management and primary protection of distribution Self diagnostic
feeders and bus couplers
F650: Backup protection of busses, transformers and User Interface
power lines Large graphic (16x40) or regular (4x20) character display
G650: Packaged generator mains failure detection Easy to use control via Shuttle key
G650: Distributed generation management device Front RS232
G650: Reliable Distributed Generation interconnection Rear wire 10/100BaseTX Ethernet for LAN connection.
protection system Rear wire CAN bus port (OPEN CAN protocol - W650)
W650: Wind turbine protection, control and monitoring Optional fibre optic 100BaseFX Ethernet, single or redundant.
W650: Distributed generation grid interconnection device Optional rear RS485 port
1 ready LED and 15 programmable LED indicators
EnerVista Integrator providing easy integration of data
Features in the 650 relay into new or existing monitoring and
Protection and Control control systems
Up to 32 Programmable digital inputs Energy metering
Up to 16 digital outputs Demand metering
Trip Circuit Supervision Trip circuit monitoring
Redundant power supply option Oscillography
Configurable PLC logic according to IEC 61131-3 Data logger
Fully configurable graphic display HMI interface Sequence of event
Alarms panel Self diagnostic
Key Benefits
Easy to use and cost effective protection and control for feeders,
motors and transformers
Effortless draw-out construction eliminates requirements for test
switches and reduces downtime
Environmental monitoring system to alarm on destructive
operating conditions and plan preventative maintenance
Easy to use interface and set up in one simple step
Accelerated Life Cycle Tested to ensure reliability of relay
operation under abnormal conditions
Advanced power system diagnostics to increase reliability
through fault and disturbance recording capabilities
Large backlit display with 40 characters for easy viewing of relay
information and settings
Flexible communications with multiple ports & protocols to allow
seamless integration into new and existing infrastructure
Easy access to information via multiple communication network
options including USB, Serial, Fiber & copper Ethernet
Reduced wiring with support for remote I/O
Reduce setup and configuration time with the Simplified Motor Features
Setup screen Monitoring and Metering
Powerful Security Audit Trail tool to increase security and Metering and Monitoring
minimize system risks by tracking setting changes Event Recorder: 256 events with 1ms time stamping
Oscillography with 32 samples per cycle and digital states
Applications
IRIG-B clock synchronization
350 Feeder Protection Relay health diagnostics
345 Transformer Protection Security audit trail
339 Motor Protection
User Interface and Programming
4X20 character LCD display
Control panel with 12 LED indicators
Front USB and rear serial, Ethernet and Fiber ports
Multiple protocols - IEC 61850 GOOSE, ModBus RTU, ModBus
TCP/IP, DNP 3.0, IEC60870-5-104, IEC60870-5-103, Profibus,
DeviceNet
EnerVista Software
Enervista Software- an industry-leading suite of software tools
that simplifies every aspect of working with Multilin devices.
Document and software archiving toolset to ensure reference
material and device utilities are up-to-date
Dimensions
Overall dimensions on 350, 339 and 345 are identical. Terminal configurations vary and
are not shown.
5.350 +_0.010
(131.1 mm +_0.25mm)
4.100 +_0.010
(104.1 mm +_0.25mm)
CIL
o 0.200
(5.1 mm)
3.96
7.93 100.6mm 6.900 +_0.010
201.51mm (175.3 mm +_0.25mm)
6.000 +_0.010
CIL (152.4 mm +_0.25mm)
4.000 +_0.010
(101.6 mm +_0.25mm)
1.73 7.89
43.8mm 200.4mm
6.62
168.2mm
Key Benefits
Ease of use and installation - same front panel programming,
common cutout
Follow technology evolution - Flash memory for product field
upgrades
Low priced scalable options - event reports, waveform capture,
recloser, breaker fail
Reduce troubleshooting and maintenance cost - Event reports,
waveform capture
Design flexibility - Easy to use programming logic
Asset monitoring - Breaker health, and breaker failure protection
Access to information - Modbus RTU communications
AC/DC power supply
Easy access via front panel keypad or communication links
Applications
Feeder protection Features
Main protection for small generators and motors Features and Benefits
Backup/Auxiliary protection for transformers, motors, Digital relay
generators and busbars Incorporates protection, and control
Overload protection Local and remote user interfaces
Automatic transfer equipment Internal memory
Load shedding and restoration schemes Diagnostic features - event recording, and oscillography
Backup directional overcurrent protection User Interface and Programming
Reverse power protection Front Panel LEDs, key pad, and 2x16 character LCD display
Synchrocheck 6 LED indicators, 4 configurable in function and color
Front RS232 and rear RS485 ports using ModBus RTU protocol