0% found this document useful (0 votes)
2K views1,216 pages

BuyLog Smart Catalog

GE

Uploaded by

YoucefChaabna
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
2K views1,216 pages

BuyLog Smart Catalog

GE

Uploaded by

YoucefChaabna
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1216

GE

Industrial Solutions

BuyLog

Low and Medium Voltage Components and Equipment


GE
Industrial Solutions

Contact Information
Customer Service
For general customer service requests
Telephone 800-GE1-STOP (800-431-7867)
Email GE.1STOP_REPLY@GE.com

Post-Sales Service
For initiating or updating post-sales service issues and warranty cases
Web www.geelitenet.com (EliteNet)
Telephone 888-GE-RESOLVE (888-437-3765)

Publications Orders
For additional catalogs or other publications
Web www.geindustrial.com
Telephone 309-664-1513

GE Parts SuperCenter
For industrial renewal parts and components (also see page 9)
Web www.PartsSuperCenter.com
Telephone 800-727-8443

On-Site Field Service


For on-site field service and support (also see page 8)
Telephone Your local sales office or 888-GE4-SERVICE (888-434-7378)
International 540-378-3280

Speedi and EliteNet Support


For initiating Speedi or EliteNet issues
Telephone 866-305-8170

Motors
For standard or custom motors, 1-100,000 HP
Web www.geindustrial.com or www.gemotors.com
Telephone 800-541-7191

Motor Parts
For Genuine GE parts built to original designs using the latest materials and manufacturing processes
Telephone 800-458-0451
Email motorparts@ge.com

2013 General Electric Company, All Rights Reserved.


TM indicates a trademark of the General Electric Company and/or its subsidiaries.
Section Updated 08 / 2016

BuyLog Introduction
Quick Index and Table of Contents
Quick Index Table of Contents
1 Load Centers and Circuit Breakers Section 1: Load Centers and Circuit Breakers
Q-Line Circuit Breakers Product Features and Benefits........1-2
2 Modular Metering PowerMark Gold Load Centers
Product Features and Benefits ........................................................1-3
3 Electric Vehicle Charging Stations PowerMark Gold and Plus Load Centers
Product Number Guides......................................................................1-4
4 Safety Switches
Q-Line Plug-in Circuit Breakers............................................................1-5
Special Purpose Circuit Breakers ........................................................1-6
5 Surge Protection Devices (SPD)
PowerMark Gold and Plus Single-Phase Load Centers
6 Molded Case Circuit Breakers Main Lug Convertible to Main Breaker.........................................1-9
Main Breaker Factory Installed .....................................................1-12
7 Circuit Breaker Enclosures PowerMark Plus Three-Phase Load Centers
Main Circuit Breakers or Main Lugs Factory Installed .......1-14
Low Voltage Power &
8 Insulated Case Circuit Breakers PowerMark Gold Load CentersSpecialty Panels ...................1-17
Disconnect Switches and PowerMark Gold Meter Socket Load Centers ............................1-18
9 Operating Mechanisms Field Installed Accessories...................................................................1-24
Wiring Diagrams ......................................................................................1-30
10 Dry Type Transformers Load Centers and Meter Socket Load Centers
Knockouts................................................................................................1-37
11 Panelboards

12 Switchboards Section 2: Modular Metering


Mini Mod III Nomenclature.....................................................................2-2
13 Busway Mini Mod IIIRing Type and Ringless................................................2-3
Mini Mod IIITenant Main Circuit Breakers ...................................2-4
14 Automatic Transfer Switches Mini Mod IIIFactory Installed Accessories...................................2-5
Mini Mod IIIField Installed Accessories.........................................2-6
15 Motor Control CentersLow Voltage Meter Mod III Nomenclature .................................................................2-7
Meter Mod IIIHow to Order; Short Circuit Ratings ..................2-8
16 Switchgear Low Voltage
Meter Mod IIIModular Metering Series Ratings........................2-9
Entellisys 5.0 Low-Voltage Switchgear Meter Mod IIIMain Breaker Modules,
17 Single-Phase and Three-Phase.....................................................2-11
18 Medium Voltage Equipment Factory Installed Accessories ........................................................2-13
Meter Mod IIIMain Fusible Modules,
Paralleling Switchgear Single-Phase and Three-Phase.....................................................2-14
19 Critical Power Products
Factory Installed Accessories ........................................................2-15
20 Uninterruptible Power Supplies Meter Mod IIIMain Fusible with Pull
Box and Main Lug Modules
21 Telecommunication Hardware Single-Phase and Three-Phase.....................................................2-16
Factory Installed Accessories ........................................................2-17
22 Relays and Meters Meter Mod IIIMain Pull Box
Modules and Accessories
23 Meters and Instrument Transformers Single-Phase and Three-Phase.....................................................2-18
Capacitors, Arresters and Meter Mod IIIMeter Stack Modules,
24 Harmonic Filters Single-Phase Plus Accessories ......................................................2-19
Distribution TransformersMedium Meter Mod IIIMeter Stack Modules,
25 and High Voltage Three-Phase Plus Accessories.......................................................2-23
26 DC Power Systems Meter Mod IIIMeter Stack Modules,
Phase Balancing...................................................................................2-24
27 RV Power Pedestals Meter Mod IIIApplications Where
Center-Feeding Main Module is Required................................2-25
28 GE Publication Index Mini Mod IIIEnclosure Knockout Dimensions..........................2-26
Meter Mod IIIEnclosure Knockout Dimensions......................2-27
29 Time Current Curves and
Outline Drawings
30 GE Product Index

2013 General Electric Company, All Rights Reserved.


TM indicates a trademark of the General Electric Company and/or its subsidiaries.

Rev. 11/13 www.geindustrial.com BuyLog Catalog 1


Data subject to change
without notice
BuyLog Introduction
Table of Contents
Section 3: Electric Vehicle Charging Stations Cable-In Cable Out (lug-lug) 240V Class.......................................6-25
Introduction .....................................................................................................3-2 DIN-Rail Mount 240V Class .................................................................6-27
Selection Guide ..............................................................................................3-3 Cable-In Cable Out (lug-lug) 240V Class.......................................6-28
Commercial WattStation Molded Case Switches 240V Class..................................................6-29
Overview, Features and Benefits ........................................................3-4 Accessories 240V Class ........................................................................6-30
WattStation Pedestal EV Charger Thermal Magnetic Trip
Specifications and Ordering Information ....................................3-5 15-100A Type TEY/TEYF Bolt-On ......................................................6-32
WattStation Wall Mount EV Charger 15-125A Type TEYD/TEYH/TEYL ........................................................6-33
Specifications and Ordering Information ....................................3-6 10-150A E-150 Line Types TEB, TED, THED ................................6-35
Commercial DuraStation 125-600A J600 Line Types TJJ, TJK, THJK....................................6-37
Overview, Features and Benefits ........................................................3-7 Internal Accessories Molded Case Circuit Breakers
Specifications and Ordering Information........................................3-8 Accessory Devices and Ratings........................................................6-39
Connect Software Auxiliary Switches....................................................................................6-40
Overview, Features and Benefits ........................................................3-9 Shunt Trip ....................................................................................................6-41
Specifications and Ordering Information.....................................3-10 Undervoltage Release ...........................................................................6-43
Residential Charging Stations Wall Mount Units Spectra RMS
Overview, Features and Benefits......................................................3-11 15-150A, SE150 Frame .........................................................................6-45
Specifications and Ordering Information.....................................3-12 70-250A, SF250 Frame .........................................................................6-47
125-600A, SG600 Frame......................................................................6-49
Section 4: Safety Switches 300-1200A, SK1200 Frame.................................................................6-52
Spectra RMS with microEntelliGuard Trip Unit
Quick Selection Guide, Enclosure Types...................................4-2
Features .......................................................................................................6-54
General Duty, Type TG .................................................................4-5
microEntelliGuard Trip Unit Characteristics ..............................6-55
Heavy Duty, Type TH....................................................................4-7
How to Order .............................................................................................6-56
Heavy Duty Stainless Steel, Type TH ......................................4-11
60-600A, SG600 Line..............................................................................6-58
Mill Duty, Type TH.......................................................................4-13
300-1200A, SK1200 Line......................................................................6-60
Double Throw Switches, Type TC, TDT....................................4-15
Accessories for Spectra RMS Circuit Breakers with
Emergency Power Transfer Switches, Type TC .....................4-18
microEntellGuard Trip Units
AC Disconnects ..........................................................................4-19
Power Management System Accessories....................................6-62
Accessories: NEMA Type 1 and 3R Enclosures ......................4-20
Other Accessories....................................................................................6-66
Accessories: NEMA Type 4/4X, 12 and
Internal Accessories ...............................................................................6-67
Mill Duty Enclosures.............................................................4-22
Record Plus
Additional Accessories ..............................................................4-24
15-100A, FB Line ......................................................................................6-69
Enclosure and Knockout Dimensions ............4-26 through 4-36
FB Internal Accessories.........................................................................6-73
FB External Accessories........................................................................6-74
Section 5: Surge Protection Devices (SPD) 15-100A, FC Line......................................................................................6-75
Critical Power Products FC Internal Accessories.........................................................................6-78
Introduction ..................................................................................................5-2 FC External Accessories........................................................................6-79
Integrated Tranquell ME (to connect with 25-250A, FE Line ......................................................................................6-80
GE A Series Panelboards) .................................................................5-3 FE Internal Accessories.........................................................................6-82
Integrated Tranquell HE and ME FE External Accessories........................................................................6-82
(for GE Distribution Equipment) ........................................................5-5 100-600A, FG Line...................................................................................6-84
Tranquell 9X and 24X (Box Extensions for FG with PremEon S ................................................................................6-85
GE A Series Distribution Equipment) ...........................................5-8 FG with SMR2 ...........................................................................................6-86
Tranquell HE and ME (Wall Mount)................................................5-12 FG Internal Accessories ........................................................................6-88
Tranquell ME and LE (Wall Mount).................................................5-18 FG External Accessories .......................................................................6-89
Tranquell DIN Rail Mount ...................................................................5-20 Molded Case Switches 100-1200 A ......................................6-90
Protection Block Assembly..................................................................5-22 Motor Circuit Protectors
3-250A Spectra RMS Mag Break ....................................................6-91
Section 6: Molded Case Circuit Breakers 125-1200A Spectra RMS Mag Break ............................................6-92
Industrial Circuit Breakers 25-600A Record Plus Mag Break......................................................6-93
How to Order................................................................................................6-2 External Accessories
Features ..........................................................................................................6-4 Cable Operators .......................................................................................6-94
Quick Reference Guide ............................................................................6-6 Flange-Mounted Operators ................................................................6-96
Q-Line Circuit Breakers Door Mounted Operators.....................................................................6-98
Plug-In 120/240V Class.........................................................................6-14 Motor Operators and Plug-in Hardware....................................6-100
Plug-In 240V Class ..................................................................................6-16 Mechanical Interlocks and Locking Devices............................6-101
Bolt-On 240V Class .................................................................................6-20 Breaker Mounting Hardware and Kits ........................................6-102

2 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Page Updated 08 / 2016

BuyLog Introduction
Table of Contents
Lugs and Associated Hardware.....................................................6-103 Interrupting Capacity and Withstand Ratings ........................8-108
Neutral Grounds and Sensors.........................................................6-105 How to Order...........................................................................................8-109
Plug-in Hardware ..................................................................................6-106 Frame Selection (Old Structure) .....................................................8-110
Trip Unit Selection.................................................................................8-111
Section 7: Circuit Breaker Enclosures Enhanced MicroVersaTrip Rating Plug Selection.................8-113
NEMA Type 1 Enclosures .............................................................7-2 Stationary and Draw-out Switch Selection ..............................8-114
NEMA Type 3R Enclosures...........................................................7-3 Stationary and Draw-out Breaker Accessories ......................8-115
NEMA Type 12 Enclosures ...........................................................7-4 Stationary Breaker Mounting Kits .................................................8-121
NEMA Type 4/4X Enclosures .......................................................7-5 Stationary Breaker Mounting Kits,
Hubs and Other Accessories ......................................................7-6 Wall Mounted Enclosures, Floor Mounted Enclosures .....8-122
Dimensions and Outline Drawings............................................7-7 Neutral Current Sensors and
Dimensions and Knockout Drawings........................................7-8 POWER LEADER Accessories ......................................................8-123
Draw-out Breaker Accessories.......................................................8-124
Section 8: Low Voltage Power & Insulated Case Circuit Breakers Reference Publications............................................................8-126
Low Voltage Power and DC Circuit Breakers Section 9: Disconnect Switches and Operating Mechanisms
EntelliGuard G Low Voltage Power Circuit Breakers............8-2
HPC High-Pressure Contact Switch
Overview and Functions ........................................................................8-2
Overview.........................................................................................................9-2
EntelliGuard TU Trip Units.....................................................................8-4
HPC Switch, New Generation, Nomenclature System............9-6
Product Nomenclature ............................................................................8-5
Frame Product Number Nomenclature...........................................9-8
Cassettes Nomenclature......................................................................8-11
EntelliGuard Control Unit Nomenclature....................................9-10
Accessories.................................................................................................8-13
Application Information, Outlines and Dimensions.................9-11
WavePro Circuit Breakers with EntelliGuard TU,
How to Order .............................................................................................9-13
Power+, Enhanced MicroVersaTrip Plus and
Accessories.................................................................................................9-14
MicroVersaTrip PM Trip Unit Systems .............................8-24
Reference Publications .........................................................................9-22
WavePro Low Voltage Power Circuit Breakers .....................8-26
Premium Duty QMW, Heavy Duty QMR
OEM Substructures and Substructure Accessories .............8-40
Individual Components.........................................................................9-23
Trip Units......................................................................................8-49
Factory Assembled Fuse Clips...........................................................9-25
Overview EntelliGuard TU, Power+ and
Handle Operators
Enhanced MicroVersaTrip .............................................................8-49
Product Ordering Tables.......................................................................9-28
Product Number Nomenclature System ......................................8-55
Accessories and Modifications..........................................................9-29
Trip Unit Conversion Kits Introduction...................................8-66
General-Duty HCI
Overview EntelliGuard TU, and
Individual Components.........................................................................9-31
MicroVersaTrip PM Conversion Kits ...........................................8-67
TDR Handle Mechanism
Remanufactured MVT Trip Unit
Handle Operating Mechanisms ........................................................9-33
Overview and Features......................................................................8-69
FD1 Fusible IEC Style
ProTrip Trip Unit Conversion Kits Selection Guide .................8-70
Individual Components.........................................................................9-34
ProTrip Rating Plugs .............................................................................8-74
Accessories.................................................................................................9-35
EntelliGuard TU Trip Unit Conversion
Outlines and Dimensions .....................................................................9-37
Kits Selection Guide.............................................................................8-76
DILOS Nonfusible Vu-Break IEC Style
EntelliGuard TU Trip Rating Plugs ..................................................8-80
Individual Components.........................................................................9-38
EntelliGuard TU Trip Unit Conversion Kit
Accessories.................................................................................................9-39
Accessories and Hardware ..............................................................8-81
Outlines and Dimensions .....................................................................9-40
Trip Unit Accessories..............................................................................8-83
Asbestos Free Arc Quencher Replacement Kits ...................8-85 Section 10: Dry Type Transformers
Gerapid High Speed DC Circuit Breakers...............................8-86
General Information
Features and Benefits ...........................................................................8-86
Types QB, QMS, QL ..................................................................................10-2
Technical Data ..........................................................................................8-88
General Purpose
Outline Drawings and Dimensions..................................................8-89
Single-Phase DOE 2016 Efficiency, Aluminum...........................10-4
Insulated Case Circuit Breakers
Single-Phase DOE 2016 Efficiency, Copper.................................10-5
Power Break II............................................................................8-91
Three-Phase DOE 2016 Product Number Nomenclature.....10-6
Features .......................................................................................................8-91
Three-Phase DOE 2016 Efficiency, Aluminum ...........................10-9
Construction Options .............................................................................8-92
Three-Phase DOE 2016 Efficiency, Copper...............................10-11
EntelliGuard TU Trip Unit Features ................................................8-93
K-Factor
Power+ Trip Unit Features...................................................................8-94
Three-Phase DOE 2016 Efficiency, Aluminum.........................10-12
Enhanced MicroVersaTrip Trip Unit Features...........................8-95
Three-Phase DOE 2016 Efficiency, Copper...............................10-16
Trip Unit Characteristics .......................................................................8-96
K-Factor Low Noise
Power Break II Nomenclature System.........................................8-99
Three-Phase DOE 2016 Efficiency, Aluminum.........................10-20
Product Number Nomenclature System ...................................8-104
Three-Phase DOE 2016 Efficiency, Copper...............................10-22

Rev. 11/13 www.geindustrial.com BuyLog Catalog 3


Data subject to change
without notice
Page Updated 08 / 2016

BuyLog Introduction
Table of Contents
Low Noise Merchandisable Kits and Sizing Information...........................11-28
Three-Phase DOE 2016 Efficiency, Aluminum.........................10-24 Terminal Lugs..........................................................................................11-29
Three-Phase DOE 2016 Efficiency, Copper...............................10-25 PCU Selection..........................................................................................11-30
Noise Isolation Guard I Interior, Enclosure Options................................................................11-31
Three-Phase DOE 2016 Efficiency, Aluminum.........................10-26 Integrated Submetering Panelboard...........................................11-33
Three-Phase DOE 2016 Efficiency, Copper...............................10-27 Renewal Parts Modular Concept...................................................11-34
Noise Isolation Guard II .......................................................10-28 Renewal Parts Circuit Breaker Sizing...........................................11-35
Three-Phase DOE 2016 Efficiency, Aluminum.........................10-29 Replacement Boxes and Fronts .....................................................11-36
Three-Phase DOE 2016 Efficiency, Copper...............................10-30 Renewal Parts Product Number Structure ...............................11-38
Harmonic Mitigating Guard III Renewal Parts Mounting Hardware .........................................11-41
Three-Phase DOE 2016 Efficiency, Copper...............................10-31 Renewal Parts Main Lug Modules;
Servicenter Mini-Unit Substations Neutral and Ground Kits.................................................................11-46
Integral Transformer and Distribution Center ...................10-32 Renewal Parts Accessories...........................................................11-47
Single-Phase and Three-Phase DOE 2016 Efficiency ..........10-33 Renewal Parts Interiors, Boxes and Fronts ...........................11-48
Outlines, Dimensions, Wiring Diagrams.....................................10-34 Renewal Parts Type SCP Panelboards ....................................11-49
Totally Enclosed, Nonventilated TENV ..............................10-35 Renewal Parts Type CCB and QMR Panelboards ...............11-50
Aluminum and Copper DOE 2016 Efficiency ...........................10-36 Available Publications .............................................................11-53
Midtapped
Aluminum DOE 2016 Efficiency......................................................10-37 Section 12: Switchboards
Copper DOE 2016 Efficiency............................................................10-38 Evolution Series Switchboards ............................................................12-2
Drive Isolation Spectra Series Switchboards ................................................................12-5
Three-Phase.............................................................................................10-40 Commercial Metering Switchboards ..................................................12-8
Accessories and Lugs ..............................................................10-42 Spectra Integrated Switchboard Solutions.................................12-11
Enclosure Parts.........................................................................10-44 GE GenTower Generator Switchboard............................................12-17
Wiring Diagrams ......................................................................10-45 Merchandised and Metering Switchboards
Dimensions ................................................................................10-46 Jiffy II-Spectra ......................................................................................12-19
General Purpose Transformers in Enclosures Jiffy III Switchboards ...........................................................................12-24
Single-Phase............................................................................................10-48
Buck-Boost Encapsulated Transformers .............................10-51 Section 13: Busway
Selection Tables .....................................................................................10-54
Connection Diagrams .........................................................................10-61 Busway Overview ....................................................................................13-2
Open Core and Coil Transformers ........................................10-62 Busway Short-Circuit Ratings ............................................................13-3
Machine Tool Applications................................................................10-63 Busway Plug Short-Circuit Ratings..................................................13-4
Control........................................................................................................10-64 Spectra Series Busway, Sandwich Bus
Options and Fusing Guide ................................................................10-66 Application ..................................................................................................13-5
Wiring Diagrams ...................................................................................10-67 Aluminum Conductors ..........................................................................13-8
Outlines and Dimensions ..................................................................10-68 Copper Conductors ..............................................................................13-12
CE-Rated....................................................................................................10-69 Spectra RMS Busway, Sandwich Bus
Circuit Breaker Busway Plugs .........................................................13-20
Circuit Breaker with MicroVersaTrip Plus Trip Units ...........13-25
Section 11: Panelboards
Spectra Series Busway, Sandwich Bus
A-Series II Panelboards Plugs, Fusible, Conversion Kits........................................................13-29
Applications................................................................................................11-3 Plug Options ............................................................................................13-33
Types..............................................................................................................11-4 Outlines, Dimensions and Weights...............................................13-35
Terminal Lugs ............................................................................................11-7 Spectra Series Busway, Low Amp
Pricing and Ordering ..............................................................................11-8 Application and Product Numbers ...............................................13-44
Column Panels ..........................................................................................11-9 Aluminum Conductors........................................................................13-46
Column Field Installed Kits/Replacement Copper Conductors ..............................................................................13-50
Parts/Enclosures.................................................................................11-10 Circuit Breaker Busway Plugs .........................................................13-58
Lighting Control PanelRemote Operated Outlines, Dimensions and Weights...............................................13-62
Circuit Breakers...................................................................................11-11 Flex-A-Power Busway
Pro-Stock Panelboards Unassembled.....................................11-13 Aluminum Conductors........................................................................13-66
Product Options .....................................................................................11-19 Copper Conductors ..............................................................................13-68
Accessories ..............................................................................................11-20 Type DH Plugs.........................................................................................13-70
Power Panelboards ..............................................................................11-21 Dimensions...............................................................................................13-73
Branch Circuit Monitoring.................................................................11-23 LW Busway
AMP1 Integrated Power and Energy............................................11-24 Replacement Parts, Application.....................................................13-74
Spectra Series Panelboards..................................................11-25 Replacement Parts, Dimensions....................................................13-76
Fusible Switches Load and Interrupting Ratings ...................11-26 Type LTG Plug-in, Application ..........................................................13-78

4 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
BuyLog Introduction
Table of Contents
Outlines and Dimensions ..................................................................13-80 Switchgear Type Power/Vac
Armor-Clad Busway Introduction, Publications....................................................................18-8
Transition Sections and Accessories ...........................................13-81 Power/Vac Vacuum Metalclad Switchgear,
Busway Plugs..........................................................................................13-82 and Breakers...........................................................................................18-9
Options and Additions ........................................................................13-87 Characteristics, Symmetrical Rating Basis ...............................18-10
Flex-A-Power Busway Vacuum Circuit Breakers and Frames ........................................18-11
Types FVA, FVK and LVDP Application.........................................13-88
Busway Plugs..........................................................................................13-91 Section 19: Paralleling Switchgear Critical Power Products
Outlines and Dimensions ..................................................................13-94 Paralleling Switchgear...............................................................19-2
Type DE Busway Energy Commander ...............................................................................19-3
Plugs for Obsolete DE Busway........................................................13-95 System Applications ...............................................................................19-5
Ordering Information .............................................................................19-6
Section 14: Automatic Transfer Switches
Automatic Transfer Switches...................................................14-2 Section 20: Uninterruptible Power Supplies
ATS (Residential) / ZTX Series..............................................................14-4 Power Quality Services..............................................................20-2
ATS (Commercial) / ZTG Series...........................................................14-6 Digital Energy VCL Series ........................................................20-4
ATS (Specification) / ZTS Series .......................................................14-15 Digital Energy VH Series (700-2000 Rackmount and/or Tower)
ATS (Specification) / ZTE Series .......................................................14-32 Description, Applications, Features and Benefits.....................20-5
ATS (Specification) / ZTED Series....................................................14-34 Technical Specifications and Dimensions....................................20-6
ATS (Specification) / ZTECT Series..................................................14-36 Product Tables UPS and Battery Packs.....................................20-7
ATS (Specification) / ZBTE Series ....................................................14-38 Digital Energy GT Series 120 V (3000 VA Tower)
ATS (Specification) / ZBTED Series .................................................14-40 Description, Applications, Features and Benefits ..................20-10
ATS (Specification) / ZBTECT Series ...............................................14-42 Technical Specifications and Dimensions.................................20-11
Product Tables UPS ..........................................................................20-11
Section 15: Motor Control CentersLow Voltage Digital Energy GT Series 120 V (3000 19" Rackmount)
Motor Control Centers Introduction .......................................15-2 Description, Applications, Features and Benefits ..................20-12
EVOLUTION SERIES E9000 Key Benefits ................................15-3 Technical Specifications and Dimensions.................................20-13
Motor Control Centers Features (SC/MC Program)..............15-4 Product Tables UPS and Battery Packs ..................................20-13
GE Fastrac Program MCC Units Quick Selection Guide, E9000 Digital Energy GT Series (5kVA and 6kVA Tower/Rackmount)
Motor Control Starter Units.................................................................15-5 Description, Features and Benefits ..............................................20-14
Motor Control Feeder Units.................................................................15-9 Technical Specifications and Dimensions.................................20-15
MCC Sections ..........................................................................................15-11 Product Tables UPS and Battery Packs ..................................20-16
Renewal Parts.........................................................................................15-13 Digital Energy GT Series (8kVA and 10kVA Tower/Rackmount)
GE Fastrac Program MCC Units Quick Selection Guide, Description, Features and Benefits ..............................................20-17
CR8000 and Spectra Technical Specifications and Dimensions.................................20-18
Motor Control Starter Units..............................................................15-14 Product Tables UPS and Battery Packs ..................................20-19
Motor Control Feeder Units..............................................................15-18 Digital Energy LP11U Series 208 V (Single-Phase 5-10 kVA)
Renewal Parts.........................................................................................15-19 Description, Features and Benefits ..............................................20-20
Technical Specifications and Dimensions.................................20-21
Section 16: Switchgear Low Voltage Product Tables UPS and Battery Packs ..................................20-22
Introduction.................................................................................16-1 Digital Energy LP33U Series 208 V (Three-Phase 10-100 kVA)
AKD-10 Low-Voltage Switchgear ............................................16-3 Description, Features and Benefits ..............................................20-24
AKD-20 Low-Voltage Switchgear ............................................16-3 Technical Specifications and Dimensions.................................20-25
Arc Vault Arc Flash Protection System .................................16-4 Product Tables UPS and Battery Cabinets ............................20-26
Digital Energy SG Series 480 V (Three-Phase 10-750 kVA)
Section 17: Entellisys 5.0 Low-Voltage Switchgear Description, Features and Benefits ..............................................20-31
Technical Specifications and Dimensions (10-150 kVA) .....20-33
Layout and sizing .......................................................................17-2 Product Tables (10-150 kVA) UPS, Battery Cabinets,
Transformers and Bypass Panels...............................................20-33
Section 18: Medium Voltage Equipment Technical Specifications and Dimensions (225-300 kVA) ..20-40
MV One Line.................................................................................18-2 Product Tables (225-300 kVA) ) UPS, Battery Cabinets,
Motor Control Medium Voltage (Limitamp) Transformers and Bypass Panels .............................................20-40
Introduction, Features, Types, Options, References ................18-3 Technical Specifications and Dimensions (400-500 kVA) .....20-43
Specifications, Ratings, Equipment Product Tables (400-500 kVA) UPS, Battery Cabinets,
Reference Publications ......................................................................18-4 Transformers and Bypass Panels .............................................20-43
Product Scope ...........................................................................................18-5 Software and Connectivity Products (10-500 kVA) ...............20-45
Renewal Parts............................................................................................18-6 Spare Parts, Options and Accessories (10-500 kVA) ............20-46
Services and Commissioning (10-500 kVA) ..............................20-47

Rev. 11/13 www.geindustrial.com BuyLog Catalog 5


Data subject to change
without notice
BuyLog Introduction
Table of Contents
Digital Energy TLE Series (225-1500 kW) Motor Protection ......................................................................22-90
Description, Features and Benefits ..............................................20-48 Motor Protection Selector Guide ..................................................22-92
M60 Medium to Large Motor Protection...................................22-94
Section 21: Telecommunication Hardware 469 Medium to Large Motor Protection....................................22-96
Introduction.................................................................................21-1 369 Small to Medium Motor Protection ....................................22-97
Fiber Closure Hardware ............................................................21-2 369 Draw-out Motor Protection....................................................22-99
Cable Location Surge Protectors.............................................21-4 339 Small to Medium Motor Protection..................................22-101
269Plus Small to Medium Motor Protection .............................22-103
Section 22: Relays and Meters 239 Small to Medium Motor Protection..................................22-104
MM300 Low Voltage Motor Management...........................22-105
Protection & Control MM2 Low Voltage Motor Management..................................22-107
Protection & Control Product Families ...................................22-3 SPM Synchronous Motor Protection.........................................22-109
UR Family Protection System............................................................22-4 Specialized Protection, Control and Recording ................22-110
SR Enhanced Drawout Protection System...............................22-13 C60 Breaker Monitoring and Control .......................................22-111
650 Mid-range Protection System ...............................................22-14 C30 I/O Logic Controller .................................................................22-113
SR 3-Series Protection .......................................................................22-15 N60 Network Stability and Synchrophasor Measurement .....22-115
MII Modular Protection System .....................................................22-17 C70 Capacitor Bank Protection ..................................................22-117
Generator Protection...............................................................22-22 C90Plus Automation Control System ...........................................22-119
Generator Protection Selector Guide .........................................22-23 HardFiber 61850 Process Bus .....................................................22-121
G60 Medium to Large Generator Protection ..........................22-24 MIV II Voltage/Frequency Protection .......................................22-123
G30 Combined Generator and Transformer Protection....22-26 MIN II Ground Protection ...............................................................22-124
489 Small to Medium Generator Protection ...........................22-28 RRTD Remote RTD Metering Module for the 369 ...............22-125
G650 Distributed Generator Protection ....................................22-30 DDFR Distributed Digital Fault Recorder ................................22-126
W650 Wind Turbine Generator Protection ..............................22-32 Single Function Protection Relays ......................................22-128
MIG II Small Generator Protection ...............................................22-34 Single Function Auxiliary Relays .........................................22-138
MIW II Directional Power/Loss of Field Protection ...............22-35 Substation Gateways and RTU ............................................22-140
Transformer Protection...........................................................22-36 D400 Advanced Substation Gateway......................................22-140
Transformer Protection Selector Guide.....................................22-37 D20MX Substation Controller ......................................................22-142
T60 Medium to Large Transformer Protection ......................22-38 D.20 RIO Distributed I/O Controller ...........................................22-144
T35 6 Winding Transformer Protection .....................................22-40 D25 Substation Controller.............................................................22-145
745 Medium to Large Transformer Protection ......................22-42 Metering
345 Small to Medium Transformer Protection.......................22-44 Digital Metering......................................................................22-147
Transmission Line Protection ................................................22-46 Digital Metering Family Selection Guide ................................22-148
Transmission Protection Selector Guide ...................................22-48 PQM II Power Quality Meter .........................................................22-149
L90 Line Current Differential Protection....................................22-50 EPM 9900 Advanced Power Quality Meter............................22-150
L60 Phase Comparison Protection ..............................................22-52 EPM 9800 Socket Mounted Power Quality Meter ..............22-152
L30 Line Current Differential System..........................................22-54 EPM 9000 Advanced Power Quality Meter............................22-154
D90Plus Sub-Cycle Distance Protection........................................22-56 EPM 7000 Revenue Class PQ Meter .........................................22-156
D60 Distance Protection...................................................................22-58 EPM 6010 Building Automation Meter ....................................22-158
D30 Backup Distance Protection..................................................22-60 EPM 6000 Revenue Class Power Meter ..................................22-159
Bus Protection...........................................................................22-62 EPM 2200 Power Meter ..................................................................22-160
Bus Protection Selector Guide .......................................................22-63 EPM 4500 Multi-tenant Sub-Metering System ....................22-161
B95Plus Busbar Protection ..................................................................22-64 EPM 1500 Single-point Sub-Metering System.....................22-164
B90 Multiple Section Busbar Protection....................................22-66 EPM 7100 Energy Submeter w/WIFI and Logging ............22-166
B30 Busbar Protection.......................................................................22-68 EPM 6100 Energy Submeter w/WIFI ........................................22-167
MIB High Impedance Busbar Protection ..................................22-70 GE Meter in a Box (MIB) ..................................................................22-168
HID High Impedance Auxiliary Protection Module .............22-71 Communications
Distribution Feeder Protection ..............................................22-72 Multiplexers.............................................................................22-170
Distribution Feeder Protection Selector Guide ..........................22-74 Multiplexer Family Overview........................................................22-171
F60 Feeder Protection with Hi-Z Detection .............................22-76 JMUX SONET Multiplexer ...............................................................22-174
F35 Multiple Feeder Protection .....................................................22-78 JMUX T1 Multiplexer.........................................................................22-174
750/760 Comprehensive, Draw Out Feeder Protection ....22-80 TN1U SDH Multiplexer.....................................................................22-175
F650 Feeder/Bay Protection ...........................................................22-82 TN1Ue SDH Enhanced Multiplexer............................................22-175
350 50/51 Feeder Protection..........................................................22-84 VistaNET Network Management Software .........................22-176
A60 Arc Flash Detection ...................................................................22-86 MDS Wireless Solutions ..................................................................22-178
735/737 Three-Phase and Ground Feeder Protection.......22-87 Ethernet Switches ..................................................................22-181
MIF II Economical Feeder Protection with Recloser ............22-88 Multilink Family Overview..............................................................22-181
FM2 Low Voltage Feeder Protection...........................................22-89 ML3000 19 Rack-mounted Managed Switch.....................22-182

6 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
BuyLog Introduction
Table of Contents
ML2400 19 Rack-mounted Managed Switch.....................22-184 Fixed Low Voltage Power Factor Correction
ML1600 9 Panel-mounted Managed Switch ......................22-185 with Harmonic Filter Equipment.................................................24-24
ML600 Unmanaged Compact Switch .....................................22-186 Automatic Fast-Switching LV Power
Media & Protocol Converters...............................................22-187 Factor Correction Capacitors.......................................................24-26
MultiNet RS485 to Ethernet ........................................................22-188 Automatic LV Power Factor Correction Capacitors ..............24-30
Media & Protocol Converters.......................................................22-189 Automatic LV Power Factor Correction
Power Sensing Capacitors and Harmonic Filter Equipment .........................24-33
Instrument Transformers .....................................................22-190 Active Harmonic Filter .......................................................................24-35
Current Transformers......................................................................22-190 Fixed MV Power Factor Correction Capacitors.......................24-37
Low Voltage Potential Transformers........................................22-193 High Voltage Capacitor Units, Single-
Bushing Current Transformers ...................................................22-194 and Three-Phase ................................................................................24-40
Medium Voltage Instrument Transformers ..........................22-194 High Voltage Pole-Mounted, Open Stack-Rack
Control Power Transformers........................................................22-195 and Metal Enclosed Equipment ..................................................24-44
Current Transducers ........................................................................22-195 OEM High Energy Surge Protectors..............................................24-46
IEC Rated Instrument Transformers.........................................22-196 Tranquell Motor Surge Protectors
Accessories..............................................................................22-197 Motor and Generator Surge Protection Equipment ..........24-48
Switches Secondary Surge Arresters and Protective Capacitors
SB-1, SB-9, Series 95........................................................................22-197 Series 9L15F .........................................................................................24-49
SB-10, SBM, FT, RT Test Switch....................................................22-198 HV Station ArrestersPolymer and Porcelain.........................24-50
Test Equipment HV Intermediate ArrestersPolymer...........................................24-58
515, PK2, XCA, XLA............................................................................22-199 Station and Intermediate ArrestersOutline Drawings .....24-62
Terminal Blocks Station and Intermediate Class ArrestorsAccessories ....24-63
116B407, EB-25, EB-26, EB-27, IKU, EB-1, EB-2, EB-4......22-199 Distribution and Riser Pole Arresters...........................................24-64
Indicator Lights
ET-16, ET-16 LED, ET-17 .................................................................22-199 Section 25: Distribution TransformersMedium
Test Equipment and High Voltage
RTT Desktop Test Set .......................................................................22-200 Substation Transformers ..........................................................25-2
Software Three-phase Padmounted Transformers...............................25-4
EnerVista Suite......................................................................22-202 Single-Phase Pole-Mounted Transformers............................25-6
Launchpad Device Setup & Document Management.....22-203 Network Transformers ..............................................................25-7
Viewpoint Engineer Control Logic Creator & Voltage Regulators
Commissioning Toolset ................................................................22-206 VR-1................................................................................................................25-8
Viewpoint Maintenance Device Health & Bushing Potential Devices ......................................................25-11
Security Reporting ..........................................................................22-210
Viewpoint Monitoring & Data Recording................................22-214
Section 26: DC Power Systems
Integrator OPC/DDE Communications Server.....................22-224
Value Added Services CPS6000 Cabinet Power System..............................................26-2
Value Added Services ............................................................22-227 Slimline Power System ..............................................................26-3
Energy Management Systems....................................................22-227
Advanced Training Services.........................................................22-229 Section 27: RV Power Pedestals
Consulting Services ..........................................................................22-231 Introduction.................................................................................27-2
Packaged Solutions..........................................................................22-233 Tables............................................................................................27-3
Product Upgrades And Replacements Accessories ..................................................................................27-4
Product Upgrades and Replacements ...............................22-234 Dimensions and Weights ..........................................................27-5
Wire Range Tables .....................................................................27-7
Section 23: Meters and Instrument Transformers
Three-Phase Metering ...............................................................23-2 Section 28: GE Publication Index
Instrument Transformers, 600 Volt.........................................23-4 Publications Index ......................................................................28-1
Instrument Transformers, 2.5-69 kV.......................................23-5
Section 29: Time Current Curves and Outline Drawings
Section 24: Capacitors, Arresters and Harmonic Filters Time Current Curves..................................................................29-1
Line/Load Reactorsup to 600V......................................................24-2 Outline Drawings........................................................................29-5
Line/Load ReactorsThree-phase Reactors ..............................24-4
Matrix Series D Harmonic Filters .....................................................24-6 Section 30: Product Index
Protective Capacitors for AC Rotating Machines...................24-11 Product Index ..............................................................................30-1
Fixed Motor and Pump Capacitors...............................................24-13
Fixed Low Voltage Power Factor Correction
Capacitors ............................................................................................24-15

Rev. 11/13 www.geindustrial.com BuyLog Catalog 7


Data subject to change
without notice
BuyLog Introduction
888-GE4-SERVice
Electrical Service Solutions for Industry

Need a knowledgeable service provider whos there when needed most? Calling 888-GE4-SERVice connects you with
over 100 years of power system expertise, including generation, delivery, utilization and control.

Meet Day-to-Day Challenges Without Dedicated Resources


Looking for an efficient way to quickly resolve equipment problems or to cost-effectively manage ongoing service
needs? GEs field service professionals are expertly trained on GE and non-GE equipment in a wide range of applications,
which gives them the knowledge they need to function as an immediate extension of your team. From installation to
start-up and commissioning through training, maintenance and repair, GE can support you in every stage of your power
systems lifecycle.

Global Reach at a Moments Notice


GEs global network of service professionals is available 24 hours a day, seven days a week. With over 5,000 service
professionals and 60 repair facilities strategically located around the world, GE can help you address emergencies and
short turn-around requests in a single call. Our on-demand response capability, extended inventory and knowledgeable
staff can help minimize downtime and improve profitability.

Emergency response and disaster recovery services are also available:


Assessment of equipment system and fast development of recovery plans
Backup personnel ranging from craft labor to specialty engineers
Emergency power needs
Site management and logistics

Expand Your Portfolio to Include Specialty Support Services


GE can provide access to power system specialists on an as-needed basis. With over 100 years of power system
knowledge in a wide range of industries, GE has the in-house expertise to deliver an added level of service. Help maximize
a power system, extend equipment life or ensure compliance with industry and regulatory standards through service
offerings such as:
Short-circuit, load flow, harmonic and protective relay studies
Arc-flash hazard analyses
Remote monitoring & diagnostics
Predictive maintenance services

When you need onsite field service support call your local sales team or
888-GE4-SERVice
International or toll calls: 540-378-3280

8 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
BuyLog Introduction
Parts Super Center

Parts Super Center is your one-stop source for genuine renewal parts for mature GE products lines and
many current products. It also offers a variety of cost-effective services and solutions:
Factory tech support factory expertise remains even when factories do not
24-hour emergency service
Quick access to more than 300,000 part numbers
Over $30 million dollars in inventory
Fast turnaround - stock items shipped same day order is received
Inventory management programs, including JIT
Web-based electronic ordering
On-line publications and parts catalogs
Dedicated, cross-functional product teams
Customer satisfaction driven by six sigma quality

Parts Super Center parts coverage


Switchgear
Philadelphia Breaker Plant Mebane Plant
Magneblast Parts 7700/8000 Line Motor Control Center Parts
OCB Oil Circuit Breaker Parts Limitamp Starter Parts
ATB Circuit Breaker Parts

Burlington Switchgear Plant Mature Designs


AK/AKR Breaker Parts TEL Breakers TKL, TKH Breakers
PowerVac Breaker Parts TEML Breakers TJ4V, THJ4V, TJL4V Breakers
WavePro Breakers TFL Breakers TK4V, TKL4V Breakers
Entellisys Breaker Parts & Test Kits TLB4 Breakers Power Break I Breakers
TJL, TJH Breakers and Accessories

Transformers
Rome Plant Hickory Plant
Primary Substation Parts Bushing Potential Devices - Complete units
Load Tap Changers (Complete units and Inductrol Regulator Complete units and parts
parts) Step Voltage Regulator Parts
Replacement Units

Pittsfield Plant
Primary Substation Parts
Load Tap Changer Parts

Drive Systems General Purpose Control


Salem Plant CR7 Line Push Buttons
Rainbow Catalog Components 080 Line Push Buttons
Drive Boards Light Tower Products
Palm Switch
3S7505 Series Photoelectric Controls
CR360ML2 Lighting Contactors and
replacement contact blocks & coil kits
1-800-645-1601
www.PartsDirect.GE.com

Rev. 11/13 www.geindustrial.com BuyLog Catalog 9


Data subject to change
without notice
BuyLog Introduction
Auto-Updating Product Information
The GE Smart Catalog

One-Stop Access to Catalogs


Get quick access to detailed product features, product numbers,
specifications, dimensions, pricing and accessories. The follow-
ing catalogs are available:

Control Catalog General Purpose Control Components


BuyLog Low and Medium Voltage Components and
Equipment

Download both catalogs or just the one you need. Once down-
loaded, instantly access product information on- or offline.

Automatic Catalog Updates


Having the latest GE catalog information has never been quicker
or easier. When used online, you will be notified automatically
when updates are available.

Learn more about how the GE Smart Catalog works.


Go to energy.gecatalogs.com

10 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Section Updated 01 / 2017

Load Centers and Circuit Breakers Section 1

Q-Line Circuit Breakers Product Features and Benefits........1-2


PowerMark Gold Load Centers
Product Features and Benefits ........................................................1-3
PowerMark Gold and Plus Load Centers
Product Number Guides......................................................................1-4
Q-Line Plug-in Circuit Breakers............................................................1-5
Special Purpose Circuit Breakers ........................................................1-6
PowerMark Gold and Plus Single-Phase Load Centers
Main Lug Convertible to Main Breaker.........................................1-9
Main Breaker Factory Installed .....................................................1-12
PowerMark Plus Three-Phase Load Centers
Main Circuit Breakers or Main Lugs Factory Installed .......1-14
PowerMark Gold Load CentersSpecialty Panels...................1-17
PowerMark Gold Meter Socket Load Centers ............................1-18
Field Installed Accessories...................................................................1-24
Wiring Diagrams ......................................................................................1-31
Load Centers and Meter Socket Load Centers
Knockouts................................................................................................1-38

Rev. 11/13 www.geindustrial.com BuyLog Catalog 1-1


Data subject to change
without notice
Load Centers and Circuit Breakers Section 1
Q-Line Circuit Breakers
Reliability and Economy

Special Purpose Circuit Breakers Copper stabs, tin-plated for corrosion resistance,
PowerMark Gold Main Circuit Breakers make the connection reliable and permanent.
Arc Fault Circuit Interrupter
Dual Function GFCI/AFCI Ground Fault Heat-resistant thermoset cases and covers add
& Combination Arc Fault Circuit Breaker stability and structural rigidity.
Ground Fault with Self-Test Feature
Trips are easy to spot because handles trip to the
Ground Fault with Equipment Protection
center position.
Switching Neutral
HID Lighting Breaker The dedicated calibration screw is cemented (not
High Magnetic Breaker simply papered over) to prevent shifting. The result is
Molded Case Switch stable calibration for optimum trip performance.
Surge Arrester
TQ Breaker

At 1/2, THQP breakers are half the width of standard breakers, permitting the use of smaller
load centers that save money and space in both new construction and service upgrades. They
feature the same high-performance design, and meet the same stringent standards as other Q-
Line breakers. Our 1 THQL will remain the breaker of choice for many contractors. In applica-
tions where space and cost are not critical, theyre an excellent choice. But when size and money
are driving considerations, THQP breakers are the smart choice.

Enclosed circuit
breakers make it
easy and efficient
to install exterior
main breakers.

THQLSURGE surge
arresters are easy to
install and protect the
whole house comput-
ers, fax machines, televi-
Maximum protection sions, stereos, VCRs and
against all-too-common other sensitive electronic
electrical fires comes equipment from
from the new technology destructive surges.
built into GEs arc fault
circuit interrupters (AFCIs).
With its ability to detect
and interrupt arcing The NEC requires ground fault protection of receptacles outdoors and
caused by damaged wire in garages, bathrooms and spa areas. These ground fault circuit
insulation or a frayed extension cord, the AFCI takes interrupters eliminate the need for separate GFCI receptacles, protect
home and family protection to a new, higher level. against short circuits and overloads, and prevent shock by detecting
very low levels of current leaks and immediately shutting off power to
the circuit.

1-2 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Page Updated 01 / 2017

Load Centers and Circuit Breakers Section 1


PowerMark Gold Load Centers
Highest Quality and Convenience
Main breaker configura-
One-piece interior tion allows top or bottom
PowerMark Gold load centers lower your costs by making installa- removes and feed without modification
tion faster and easier, increasing application flexibility and reduc- reinstalls easily
ing inventory requirements. At the same time, they deliver obvious
and significant advances in design, function and quality. Combination
UL Listed (Panelboards No. 67) slotted/Robertson
Service Barriers included for factory installed main circuit square-drive
breaker and main circuit breaker kits (required to meet UL67 Full-length neutrals speeds screw
for service entrance applications) are easier to wire,2 wiring
Suitable for Use as Service Entrance Equipment when installed reducing installation
time and cost
in accordance with National Electrical Code All holes rated
60C/75C Conductor Rating for 14-4 wire
Single phase, 40-225A, 2-42 circuits
Main lug models field convertible to main breaker
Main breaker 22kAIC standard - factory installed Minimum 100%
All load centers top or bottom feed neutral
Indoor and outdoor rated enclosures terminations
Indoor fronts combination surface/flush
100% rated
Copper bus with tin plating standard1
split neutral
Split neutrals extend the full length of the interior for ease of wiring
on each side2
Entire main lug line converts easily to main breaker
Combination surface/flush front with spring-reinforced pan Sturdy copper bus
Combination slotted/Robertson square-drive screws on neutral,2 and galvanized box
ground, front and breaker lugs increase durability Tie bar may be
and reliability removed to split
Front packed in inner carton for added protection Accepts GE Q-Line branch neutral/ground
Field installable feed-through lugs up to 200A circuit breakers, including
Straight-through main wiring GEs exclusive 1/2" THQPs
Main breaker is clearly marked and circuit numbers are stamped
on front
Isolated ground bar is available
Compact box maintains optimum wire-bending space A complete family of meter socket load centers ring style
and ringless, wide and narrow, meter mains, farm panels and
more deliver specialized solutions for special situations.
Packaging features comprehensive
selection and application data.
Fronts are packed in inner cartons
for added protection during shipment
and at the job site.

The PowerMark Gold


line includes a wide
range of outdoor as
well as indoor units.

GEs residential load centers reach into


Main lug load centers offer an economical commercial applications as well, with riser
solution for subpanels and similar applications. panels, auxiliary gutters, three-phase units
All main lug units 125A and above convert easily with standard 22kAIC ratings, and all the
to main breaker. accessories needed to complete the job.

Accessories and Options Safety accessories convenient and easy to install


Door lock and handle Hardware kits THQLSURGE whole house surge protector
Equipment ground kits Main breaker retainers Arc fault circuit interrupter breaker, 1- or 2-pole
Sub-feed and feed-thru lugs Neutral kits Ground fault circuit interrupter breaker, 5mA and 30mA
Front filler plates Universal raintight hubs Generator transfer panel 30A or 60A, indoor or outdoor
Handle lock and ties GE AC disconnects
1Three-phase PowerMark Plus load centers have aluminum bus with copper breaker Service Barrier Kits
mounting stabs.
216 circuit and above.

Rev. 11/13 www.geindustrial.com BuyLog Catalog 1-3


Data subject to change
without notice
Load Centers and Circuit Breakers Section 1
PowerMark Gold and Plus Load Centers
Product Number Guides

Product Number Guide for Load Centers


(Product number for illustrative purposes only)

T M 42 4 20 C CU B
GE Identification Insert for Specials
G or T = Factory installed ground bar
B = Bottom feed main breaker
Type FL = Factory installed feed-through lugs
M = Main breaker D = Optional door for 6-8 circuit panel.
L = Main lug (Doors standard on all units 12
LM = Convertible circuits or greater)
PL = Main lug (Thermoplastic) W = White Front

Insert for PowerMark Gold


CU = Copper Bus
Maximum Number 1" Spaces 42 = Copper Bus Full 42 circuit panel
2, 4, 642
Enclosure Type
C = Combination surface/flush
Insert for 3-Phase 4-Wire F = Flush
Load Centers S = Surface
R = Outdoor

Bus Ampere Rating


40 = 40 Amps 20 = 200 Amps
70 = 70 Amps 22 = 225 Amps
10 = 100 Amps 30 = 300 Amps
12 = 125 Amps 40 = 400 Amps
15 = 150 Amps 60 = 600 Amps

Product Number Guide for Q-Line Plug-in Circuit Breakers


(Product number for illustrative purposes only)

T H QL 1 1* 15 GFT
GE Identification
Ground Fault/Arc Fault Circuit Interrupter
AF2 = 1- & 2-pole Combination Arc Fault
Interrupting Rating Circuit Interrupter
H = 10kAlC GFEP = 1- & 2-pole Ground Fault with
HH = 22kAlC Equipment Protection Interrupter30 mA
X = 65kAlC GFT = 1- & 2-pole Ground Fault
with Self-Test Feature Interrupter - 5 mA
DF = 1-pole Dual Function GFCI/AFCI Ground Fault
Type & Combination Arc Fault Circuit Interrupter
QL = 1" plug-in
QP = 1/2" plug-in
QB = 1" bolt-on Ampere Rating

Voltage
1 = 120/240V
Poles (1, 2, 3) 2 = 240V
*Omit character for THQP breakers, which are all 120/240V.

1-4 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Page Updated 01 / 2017

Load Centers and Circuit Breakers Section 1


Q-Line Plug-in Circuit Breakers
UL Listed (Molded Case Circuit Breakers No. 489)
Federal Government Specification Qualified (WC-375B)
60C / 75C Conductor Rating
Quick Make, Quick Break
Box Type Terminals

Q-Line Plug-in Circuit Breakers Specifications THQP130 THQP230 THQL1120


Wire Size AWG/kcmil1
Breaker Type Ampere Rating Cu Al
15-25 14-8 12-8
THQP
30-50 8-4 8-4
15-30 14-8 12-8
THQL
35-60 8-3 8-3
THHQL
70-100 6-1/0 4-1/0
TXQL
110-125 2-2/0 2-2/0
1Solid or stranded for 14-10 AWG

THQL2140 THQL32015

Q-Line Plug-in Circuit Breakers


10,000AIC 22,000AIC 65,000AIC
Type THQP 1/2-inch Module Type THQL 1-inch Module Type THHQL 1-inch Module Type TXQL 1-inch Module
120/240 Vac 120/240 Vac 120/240 Vac 240 Vac 120/240 Vac 240 Vac 120/240 Vac
Ampere Product Product Product Product Product Product
Rating Number Number Number Number Number Number
Single Pole1
152 THQP115 THQL1115 THHQL1115 TXQL1115
202 THQP120 THQL1120 THHQL1120 TXQL1120
25 THQP125 THQL1125 THHQL1125 TXQL1125
30 THQP130 THQL1130 THHQL1130 TXQL1130
35 THQP135 THQL1135 THHQL1135
40 THQP140 THQL1140 THHQL1140
45 THQP145 THQL1145 THHQL1145
50 THQP150 THQL1150 THHQL1150
Std. Pkg. 5 cartons of 20 5 cartons of 10 5 cartons of 10 5 cartons of 10

Two-Pole3: Incorporates Internal Common Trip Bar


15 THQP215 THQL2115 THQL220154 THHQL2115 THHQL220154 TXQL2115
20 THQP220 THQL2120 THQL220204 THHQL2120 THHQL220204 TXQL2120
25 THQP225 THQL2125 THQL220254 THHQL2125 THHQL220254 TXQL2125
30 THQP230 THQL2130 THQL220304 THHQL2130 THHQL220304 TXQL2130
35 THQP235 THQL2135 THQL220354 THHQL2135 THHQL220354
40 THQP240 THQL2140 THQL220404 THHQL2140 THHQL220404
45 THQP245 THQL2145 THQL220454 THHQL2145 THHQL220454
50 THQP250 THQL2150 THQL220504 THHQL2150 THHQL220504
60 THQL2160 THQL220604 THHQL2160 THHQL220604
70 THQL2170 THQL220704 THHQL2170 THHQL220704
80 THQL2180 THQL220804 THHQL2180 THHQL220804
90 THQL2190 THQL220904 THHQL2190 THHQL220904
100 THQL21100 THQL221004 THHQL21100 THHQL221004
110 THQL21110 THHQL21110
125 THQL21125 THHQL21125
Std. Pkg. 5 cartons of 10 5 cartons of 5 5 cartons of 5 5 cartons of 5 5 cartons of 5 5 cartons of 5

Three-Pole3: Incorporates Internal Common Trip Bar


15 THQL32015 THHQL32015 TXQL32015
20 THQL32020 THHQL32020 TXQL32020
25 THQL32025 THHQL32025 TXQL32025
30 THQL32030 THHQL32030 TXQL32030
35 THQL32035 THHQL32035
40 THQL32040 THHQL32040
45 THQL32045 THHQL32045
50 THQL32050 THHQL32050
60 THQL32060 THHQL32060
70 THQL32070 THHQL32070
80 THQL32080 THHQL32080
90 THQL32090 THHQL32090
100 THQL32100 THHQL32100
Std. Pkg. 5 cartons of 3 5 cartons of 3 5 cartons of 3
1UL Listed as HACR (heating, air conditioning and refrigeration).
2UL Listed as SWD (switching duty). Suitable for 120 volts ac fluorescent lighting References:
loads. Accessories Pages 1-24 thru 1-30
315-100 amp UL Listed as HACR (heating air conditioning and refrigeration). Auxiliary Switches and Shunt Trips BuyLog pages 6-40 thru 6-42
4Required for three-phase and High Leg Delta Systems only.

Rev. 11/13 www.geindustrial.com BuyLog Catalog 1-5


Data subject to change
without notice
Load Centers and Circuit Breakers Section 1
Special Purpose Circuit Breakers
60C / 75F Conductor Rating
Box Type Terminals
Quick-Make, Quick-Break
Multi-pole Breakers Incorporate Internal Common Trip

Arc Fault2
UL Listed
Arc-Fault Circuit Interrupters No. 1699
1 Pole, 120/240 Volts ac1
Ampere Rating Product Number
10,000 AIC
15 THQL1115AF2
20 THQL1120AF2
22,000 AIC
15 THHQL1115AF2
20 THHQL1120AF2
Std. Pkg. 10 Cartons of 1
As of Jan. 1, 2008, 2005 NEC requires combination AFCI.
1Combination AFCI compliant with 2008 NEC and later
2For 2-Pole shared neutral applications use two 1-pole circuit breakers with a handle tie. See DET-719 for more
details on our Arc Fault products. Arc Fault

Dual Function GFCI/AFCI Ground Fault & Combination Arc Fault Circuit Breaker
UL Listed (Available December 2014)
1 Pole, 120 Volts ac
Ampere Rating Product Number
10,000 AIC
15 THQL1115DF
20 THQL1120DF
22,000 AIC
15 THHQL1115DF
20 THHQL1120DF
Std. Pkg. 10 Cartons of 1

Ground Fault with Self-Test Feature


cULus THQL1115DF
Ground Fault Circuit Interrupters UL943 ed5 (5 milliamperes)
1-Pole, 120 Volts ac 2-Pole, 120/240 Volts ac
Ampere Rating Product Number Product Number
10,000 AIC
15 THQL1115GFT THQL2115GFT
20 THQL1120GFT THQL2120GFT
25 THQL1125GFT THQL2125GFT
30 THQL1130GFT THQL2130GFT
40 THQL2140GFT3
50 THQL2150GFT3
22,000 AIC
15 THHQL1115GFT
20 THHQL1120GFT
25 THHQL1125GFT
30 THHQL1130GFT
3 UL & CSA
THQL2120GFT
PowerMark Gold Main Circuit Breakers for use with 150A-225A PowerMark Gold Load
Centers (Includes mounting base)
UL Listed.
Description Ampere Rating Product Number Lug Size
100 THQMV100D
125 THQMV125D
Main Circuit Breaker Kits 150 THQMV150D 1-300 (cu),
22,000 AIC 175 THQMV175D 2/0-300
200 THQMV200D
225 THQMV225D
Note: Wire bending rules affect allowed wire sizes when THQMV breakers are installed in an enclosure. For load
centers, the wire range will be on the rating label. In addition, refer to the specifications for the main breaker
versions of the load center you are considering to review allowed wire ranges when a TLMXX20 load center is
converted to main breaker.
THQMV100D with filler plates

1-6 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Page Updated 01 / 2017

Load Centers and Circuit Breakers Section 1


Special Purpose Circuit Breakers
60C / 75F Conductor Rating
Box Type Terminals
Quick-Make, Quick-Break
Multi-pole Breakers Incorporate Internal Common Trip

PowerMark Gold Main Circuit Breaker Kit


For use with 125A PowerMark Gold load Centers; 22kAIC RMS symmetrical.
Description Product Number
Main Circuit Breaker Kit - Order appropriate THQL TQMH0001
10kAIC or THHQL 22kAIC breakers separately. Includes service barriers for use with THQL or
THHQL main.
1Please review the footnotes listed with the individual Load Center product numbers for proper parts needed to
convert to a main circuit breaker. This main breaker base is only applicable for 16 circuit and larger 125 amp load
centers, 12 circuit load centers with A C24 suffix, and the TLM812RCU2.
TQMH000
Ground Fault with Equipment Protection
cULus
Ground Fault Circuit Interrupters No. 943 30 milliampere ground fault trip level
1-Pole, 120 Volts ac 2-Pole, 120/240 Volts ac
Ampere Rating Product Number Product Number
10,000 AIC
15 THQL1115GFEP THQL2115GFEP
20 THQL1120GFEP THQL2120GFEP
30 THQL1130GFEP THQL2130GFEP
Std. Pkg. 10 Cartons of 1 10 Cartons of 1

Switching Neutral
UL Listed. 10kAIC RMS symmetrical.
Standard 1- or 2-pole automatic breaker plus one fully-rated, non-automatic pole.
1-Pole Plus Switching Neutral 2-Pole Plus Switching Neutral
120/240 Volts ac 120/240 Volts ac
Ampere Rating Product Number Product Number
15 THQL21WY15 THQL31WY15
20 THQL21WY20 THQL31WY20
25 THQL21WY25 THQL31WY25
30 THQL21WY30 THQL31WY30 THQL21WY30
Std. Pkg. 5 cartons of 5 5 cartons of 3

"HID" Lighting
UL Listed as HID. HID breakers have been designed to handle the current and voltage
spikes that result when gaseous discharge lamps, including fluorescent and HID lamps,
are switched on and off.
1-Pole, 120/240 Volts ac 2-Pole, 120/240 Volts ac
Ampere Rating Product Number Product Number
10,000 AIC
15 THQL1115HID2 THQL2115HID
20 THQL1120HID2 THQL2120HID
30 THQL1130HID THQL2130HID
22,000 AIC
15 THHQL1115HID2 THHQL2115HID THQL2120HID
20 THHQL1120HID2 THHQL2120HID
30 THHQL1130HID THHQL2130HID
Std. Pkg. 5 cartons of 10 5 cartons of 5
2UL Listed as SWD (switching duty). Suitable for 120 volts ac fluorescent lighting loads.

High Magnetic
UL Listed. 10kAIC RMS symmetrical
High short circuit setting suitable for circuits with inherent high-inrush load currents.
1-Pole, 120/240 Volts ac
Ampere Rating Product Number
15 THQL1115HM
20 THQL1120HM
25 THQL1125HM
30 THQL1130HM
40 THQL1140HM THQL1140HM
50 THQL1150HM
Std. Pkg. 5 cartons of 10

Rev. 11/13 www.geindustrial.com BuyLog Catalog 1-7


Prices and data subject
to change without notice
Load Centers and Circuit Breakers Section 1
Special Purpose Circuit Breakers
60C / 75F Conductor Rating
Box Type Terminals
Quick-Make, Quick-Break
Multi-pole Breakers Incorporate Internal Common Trip

Molded Case Switches


UL Listed
Without overload or short circuit protection.
2-Pole 3-Pole
Ampere Rating Product Number Product Number
120/240 Volts ac
60 TQL21Y60
100 TQL21Y100
TQL21Y100
240 Volts ac
60 TQL22Y60 TQL32Y60
100 TQL22Y100 TQL32Y100
Std. Pkg. 5 cartons of 5 5 cartons of 3

Interlocking Circuit Breakers for use in PowerMark Gold Generator Panels


Two breakers required for interlocking.
Poles Ampere Rating Product Number
2 30 THQL2130GEN
2 60 THQL2160GEN

TQ Circuit Breakers TQ1120


3/4" UL Classified Circuit Breakers for use in *Square D **QO Load Centers.
10 kAIC RMS symmetrical
1-Pole 2-Pole
Ampere Rating Product Number Product Number
15 TQ1115 TQ2115
20 TQ1120 TQ2120
30 TQ1130 TQ2130
40 TQ1140 TQ2140
50 TQ1150 TQ2150
60 TQ2160
Std. Pkg. 1 carton of 10 1 carton of 5
TQ2120
THQL 120/240 Vac, with Factory Installed Shunt1
# of Ampere 120/240 Vac
Poles Rating Wire Range2 Interrupting Rating Product Number
1 15 (1) 14-8 Cu/12-8 Al 10kA THQL1115ST1
1 20 (1) 14-8 Cu/12-8 Al 10kA THQL1120ST1
1 30 (1) 14-8 Cu/12-8 Al 10kA THQL1130ST1
1 35 (1) 8-3 Cu/8-3 Al 10kA THQL1135ST1
1 40 (1) 8-3 Cu/8-3 Al 10kA THQL1140ST1
1 45 (1) 8-3 Cu/8-3 Al 10kA THQL1145ST1
1 50 (1) 8-3 Cu/8-3 Al 10kA THQL1150ST1
1Shunt trip requires one additional pole of space.

THQL 120/240 Vac, Internal Common Trip with Factory Installed Shunt1 THQL1130ST1
# of Ampere 240 Vac
Poles Rating Wire Range2 Interrupting Rating Product Number
2 15 14-8 Cu/12-8 Al 10kA THQL2115ST1
2 20 14-8 Cu/12-8 Al 10kA THQL2120ST1
2 30 14-8 Cu/12-8 Al 10kA THQL2130ST1
2 35 8-3 Cu/8-3 Al 10kA THQL2135ST1
2 40 8-3 Cu/8-3 Al 10kA THQL2140ST1
2 45 8-3 Cu/8-3 Al 10kA THQL2145ST1
2 50 8-3 Cu/8-3 Al 10kA THQL2150ST1
2 60 8-3 Cu/8-3 Al 10kA THQL2160ST1
2 70 6-1/0 Cu/4-1/0 Al 10kA THQL2170ST1
2 80 6-1/0 Cu/4-1/0 Al 10kA THQL2180ST1 THQL2120ST1
2 90 6-1/0 Cu/4-1/0 Al 10kA THQL2190ST1
2 100 6-1/0 Cu/4-1/0 Al 10kA THQL21100ST1
3 20 14-8 Cu/12-8 Al 10kA THQL32020ST1
3 30 14-8 Cu/12-8 Al 10kA THQL32030ST1
3 40 8-3 Cu/8-3 Al 10kA THQL32040ST1
3 50 8-3 Cu/8-3 Al 10kA THQL32050ST1
3 60 8-3 Cu/8-3 Al 10kA THQL32060ST1
3 70 6-1/0 Cu/4-1/0 Al 10kA THQL32070ST1
3 80 6-1/0 Cu/4-1/0 Al 10kA THQL32080ST1
3 90 6-1/0 Cu/4-1/0 Al 10kA THQL32090ST1
3 100 6-1/0 Cu/4-1/0 Al 10kA THQL32100ST1
2Solid or stranded for 14-10 AWG.
THQL32020ST1
*Square D is a registered trademark of SNA Holdings, Inc. **QO is a registered trademark of the Square D Company.

1-8 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Load Centers and Circuit Breakers Section 1
PowerMark Gold and Plus Load Centers Load Center
1PH
Single-Phase, Three-Wire, 120/240 Vac Main Lug
Main Lugs Convertible to Main Breaker Indoor NEMA 1

Product Features
UL Listed (Panelboards No. 67)
60/75C Conductor Rating
Suitable for Use as Service Entrance Equipment when Installed
in Accordance with the National Electrical Code
22kAIC RMS symmetrical, Except Where Noted
6-42 circuit devices UL Listed for bottom mounted lugs by
installing complete unit (box, interior and front) upside down.
For a listing of CSA Listed load centers, visit geindustrial.com.

TLM2020CCU TPL412R

Main Lugs Factory Installed (TLM units convertible to main breaker),


Indoor (NEMA 1) Enclosure
Main 1 Pole, 2 Pole, 1 Pole, 2 Pole, Total Main Wire Size
Ampere 1 1 1/2 1/2 1-pole Front Box (AWG/kcmil) Equipment Product
Rating Spaces Spaces Spaces Spaces Spaces Type Feed Type1 Number Cu-Al Ground Kit Number
40 2 1 4 1 4 Surface Top 1A 14-4 TGK4 (order separately) TL240SCU1,8
Bottom
70 2 1 4 1 4 Surface Top 1A 6-3 TGK4 (order separately) TL270SCU1,8
Bottom
125 4 2 8 3 8 Combination Top 2A 1-2/0 TGL1 (order separately) TL412C1,2,8
Flush/Surface Bottom
125 4 2 8 3 8 Combination Top 2A 1-2/0 TGL1 installed TL412CT1,2,3,8
Flush/Surface Bottom
125 4 2 8 3 8 Thermoplastic Top 2 1-2/0 TGL1 (order separately) TPL412C1,2,3,8
Bottom
125 4 2 8 3 8 Thermoplastic Top 2 1-2/0 TGL1 installed TPL412CT1,2,3,8
Bottom
125 6 3 12 4 12 Flush Top 3A 6-1 TGL2 (order separately) TLM612FCU4,8
Bottom
125 6 3 12 4 12 Flush Top 3A 6-1 TGL2 (order separately) TLM612FCUD4,8
Bottom
125 6 3 12 4 12 Flush Top 3A 6-1 TGL2 installed TLM612FCUDG4,8
Bottom
125 6 3 12 4 12 Surface Top 3A 6-1 TGL2 (order separately) TLM612SCU4,8
Bottom
125 6 3 12 4 12 Surface Top 3A 6-1 TGL2 (order separately) TLM612SCUD4,8
Bottom
125 6 3 12 4 12 Surface Top 3A 6-1 TGL2 installed TLM612SCUDG4,8
Bottom
125 8 4 16 8 16 Flush Top 3A 6-1 TGL2 (order separately) TLM812FCU4,8
Bottom
125 8 4 16 8 16 Flush Top 3A 6-1 TGL2 (order separately) TLM812FCUD4,8
Bottom
125 8 4 16 8 16 Flush Top 3A 6-1 TGL2 (order separately) TLM812FCUDG4,8
Bottom
125 8 4 16 8 16 Surface Top 3A 6-1 TGL2 (order separately) TLM812SCU4,8
Bottom
125 8 4 16 8 16 Surface Top 3A 6-1 TGL2 (order separately) TLM812SCUD4,8
Bottom
125 8 4 16 8 16 Surface Top 3A 6-1 TGL2 installed TLM812SCUDG4,8
Bottom
125 14 6 20 8 24 Combination Top 18 6-2/0 Included10 TLM1212CCU7,8
Flush/Surface Bottom
125 14 6 20 8 24 White Combo Top 18 6-2/0 Included10 TLM1212CCUW7,8,9
Flush/Surface Bottom
This table continued on next page

Rev. 11/13 www.geindustrial.com BuyLog Catalog 1-9


Data subject to change
without notice
Page Updated 01 / 2017

Load Centers and Circuit Breakers Section 1


PowerMark Gold and Plus Load Centers Load Center
1PH
Single-Phase, Three-Wire, 120/240 Vac Main Lug
Main Lugs Convertible to Main Breaker Indoor NEMA 1

Main Lugs Factory Installed (TLM units convertible to main breaker),


Indoor (NEMA 1) Enclosure
Main 1 Pole, 2 Pole, 1 Pole, 2 Pole, Total Main Wire Size
Ampere 1 1 1/2 1/2 1-pole Front Box (AWG/kcmil) Equipment Product
Rating Spaces Spaces Spaces Spaces Spaces Type Feed Type Number Cu-Al Ground Kit Number
125 16 8 16 6 24 Combination Top 4 6-2/0 TGK12 and TGK24 TLM1612CCU5
Flush/Surface Bottom (order separately)
125 16 8 16 6 24 Combination Top 4 6-2/0 TGK12 and TLK20 TLM1612CCUG7
Flush/Surface Bottom installed
125 24 12 0 0 24 Combination Top 7 6-2/0 TGK24 and TGK32 TLM2412CCU5
Flush/Surface Bottom (order separately)
125 24 12 0 0 24 White Combo Top 7 6-2/0 TGK24 and TGK32 TLM2412CCUW5,9
Flush/Surface Bottom (order separately)
125 24 12 0 0 24 Combination Top 7 6-2/0 TGK24 and TLK20 TLM2412CCUG7
Flush/Surface Bottom installed
200 16 8 32 14 32 Combination Top 7 6-250 TGK32 TLM1620CCU6
Flush/Surface Bottom (order separately)
200 16 8 32 14 32 White Combo Top 7 6-250 TGK32 TLM1620CCUW6,9
Flush/Surface Bottom (order separately)
200 16 8 32 14 32 Combination Top 7 6-250 TGK32 TLM1620CCUG6
Flush/Surface Bottom installed
200 20 10 40 18 40 Combination Top 8 6-250 TGK32 TLM2020CCU6
Flush/Surface Bottom (order separately)
200 20 10 40 18 40 White Combo Top 8 6-250 TGK32 TLM2020CCUW6,9
Flush/Surface Bottom (order separately)
200 20 10 40 18 40 Combination Top 8 6-250 TGK42 TLM2020CCUG6
Flush/Surface Bottom installed
200 24 12 36 18 42 Combination Top 9 1-3/0 (Cu), TGK24 and TLK32 TLM2420C426
Flush/Surface Bottom 2/0-3/0 (Al) (order separately)
200 32 16 20 8 42 Combination Top 11 1-250 (Cu), TGK32 and TLK20 TLM3220C426
Flush/Surface Bottom 2/0-250 (Al) (order separately)
200 32 16 16 6 40 Combination Top 11 6-250 TGK32 TLM3220CCU6
Flush/Surface Bottom (order separately)
200 32 16 16 6 40 White Combo Top 11 6-250 TGK32 TLM3220CCUW6,9
Flush/Surface Bottom (order separately)
200 40 20 0 0 40 Combination Top 13 6-250 TGK42 TLM4020CCU6
Flush/Surface Bottom (order separately)
200 40 20 0 0 40 White Combo Top 13 6-250 TGK42 TLM4020CCUW6,9
Flush/Surface Bottom (order separately)
200 42 20 0 0 42 Combination Top 14 1-300 (Cu), TGK42 TLM4220CCU6
Flush/Surface Bottom 2/0-300 (Al) (order separately)
225 42 20 0 0 42 Combination Top 14 1-300 (Cu), TGK42 TLM4222CCU6
Flush/Surface Bottom 2/0-300 (Al) (order separately)
1No door
210 kAIC
3125 amp maximum branch capacity.
4For main breaker, order THQLRK2 retainer kit plus 2-pole circuit breaker. See page 1-28, 100 amp max.
5For main breaker, order TQMH000. See page 1-24. Also order 2-pole THQL, THHQL, or TXQL circuit breaker. See page 1-5.
6For main breaker, order THQMVXXXD circuit breaker from page 1-6.
7For main breaker applications, use reverse feed THQL breaker or THHQL circuit breaker (see page 1-5) and THQLRK3 breaker retainer (see page 1-28).
8No lock provision available. Use next size larger load center such as TLM1612CCU with a TDL106 accessory if locking provision is required.
9Minimum order QTY is 40 for below 24 circuits; QTY 24 for 24 circuits and above. (See DEE-590)
10Load center includes a factory installed ground bar and add-a-lug. See wiring diagram on page 1-31. A separate TGL2 can be added in the unlikey event
that another ground bar is required.

Note: See page 11-4, AL Series Lighting Panelboards as replacements for 300-600A load centers.

1-10 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Page Updated 01 / 2017

Load Centers and Circuit Breakers Section 1


PowerMark Gold and Plus Load Centers Load Center
1PH
Single-Phase, Three-Wire, 120/240 Vac Main Lug
Main Lugs Convertible to Main Breaker Outdoor NEMA 3R

Main Lugs Factory Installed (TLM units convertible to main breaker),


Outdoor (NEMA 3R) Enclosure1
Main 1 Pole, 2 Pole, 1 Pole, 2 Pole, Total Main Wire Size
Ampere 1 1 1/2 1/2 1-pole Front Feed1 Box (AWG/kcmil) Equipment Product
Rating Spaces Spaces Spaces Spaces Spaces Type Type Number Cu-Al Ground Kit Number
40 2 1 4 1 4 Top R1A 14-4 TGK4 (order separately) TL240RCU
70 2 1 4 1 4 Top R1A 6-3 TGK4 (order separately) TL270RCU
100 5 0 0 0 5 Flush Top R41 6-3 TGL1 installed TL510RT2,8
125 4 2 8 3 8 Top R1A 1-2/0 TGL1 (order separately) TL412R12
125 4 2 8 3 8 Top R1A 1-2/0 TGL1 installed TL412RT12
125 4 2 8 3 8 Top R41 1-2/0 TGL1 (order separately) TL412R22
125 4 2 8 3 8 Thermoplastic Top R1 1-2/0 TGL1 (order separately) TPL412R2,3
Front
125 4 2 8 3 8 Thermoplastic Top R1 1-2/0 TGL1 installed TPL412RT2,3
Front
125 4 3 12 4 12 Top R2A 6-1 TGK12 (order separately) TLM612RCU4
125 8 4 16 8 16 Top R2A 6-1 TGK12 (order separately) TLM812RCU4
125 8 4 16 8 16 Top R3A 6-1 TGK12 (order separately) TLM812RCU25
125 14 6 20 8 24 Top R3A 6-2/0 Included TLM1212RCU7,9
125 24 12 0 0 24 Top R4A 6-2/0 TGK24 (order separately) TLM2412RCU5
Bottom TGK32 (order separately)
150 24 12 12 4 30 Top R6A 1-3/0 (Cu), TGK24 (order separately) TLM2415RCU6
Bottom 2/0-3/0 (Al) TGK32 (order separately)
200 12 6 24 10 24 Top R5A 6-250 TGK24 (order separately) TLM1220RCU6
200 16 8 32 14 32 Top R5A 6-250 TGK32 (order separately) TLM1620RCU6
200 20 10 40 18 40 Top R6A 6-250 TGK24 (order separately) TLM2020RCU6
TGK42 (order separately)
200 24 12 36 18 42 Top R39 1-250 (Cu), TGK24 (order separately) TLM2420R42
Bottom 2/0-250 (Al)
200 32 16 16 6 40 Top R7A 1-250 (Cu), 2/0-250 (Al) TGK32 (order separately) TLM3220RCU6
Bottom
200 40 20 0 0 40 Top R8A 6-250 TGK42 (order separately) TLM4020RCU6
Bottom
225 42 20 0 0 42 Top R8A 1-300 (Cu), TGK42 (order separately) TLM4222RCU6
Bottom 2/0-300 (Al)
140-225 amp single-phase devices have removable closing caps. Larger ampere devices require field-cut openings. Order hubs separately. See page 1-27.
210 kAIC.
3125 amp maximum branch capacity.
4For main breaker, order THQLRK2 retainer kit plus 2-pole circuit breaker. See page 1-28, 100 amp maximum due to wire bending requirements.
5For main breaker, order TQMH000. See page 1-24. Also order 2-pole THQL or THHQL circuit breaker. See page 1-5.
6For main breaker, order THQMVXXXD circuit breaker from page 1-6.
7For main breaker applications, use reverse feed THQL or THHQL circuit breaker (see page 1-5) and THQLRK3 breaker retainer (see page 1-28).
8Main and branch breakers are limited to 70 amps.
9Load center includes a factory installed ground bar and add-a-lug. See wiring diagram on page 1-31. A separate TGL2 can be added in the unlikey event
that another ground bar is required.

Note: See page 11-4, AL Series Lighting Panelboards as replacements for 300-600A load centers.

Rev. 11/13 www.geindustrial.com BuyLog Catalog 1-11


Data subject to change
without notice
Load Centers and Circuit Breakers Section 1
PowerMark Gold and Plus Main Breaker Load Centers Load Center
1PH
Single-Phase, Three-Wire, 120/240 Vac Main Breaker
Main Breaker Factory Installed Indoor NEMA 1

Product Features
UL Listed (Panelboards No. 67)
60C/75C Conductor Rating
Suitable for Use as Service Entrance Equipment when Installed
in Accordance with the National Electrical Code
22kAIC RMS symmetrical, Except Where Noted
6-42 circuit devices UL Listed for bottom mounted lugs by
installing complete unit (box, interior and front) upside down.
For a listing of CSA Listed load centers, visit geindustrial.com.

TM2020CCU TM820RCUFL

Indoor (NEMA 1) Enclosure


Main 1 Pole, 2 Pole, 1 Pole, 2 Pole, Total Main Wire Size
Ampere 1 1 1/2 1/2 1-pole Front Feed Box (AWG/kcmil) Equipment Product
Rating Spaces Spaces Spaces Spaces Spaces Type Type Number Cu-Al Ground Kit Number
100 12 5 20 8 22 Combination Top 18 4-1/0 Included1 TM1210CCU2
Flush/Surface Bottom
Front
100 24 12 0 0 24 Combination Top 7 1-2/0 TGK24, TGK32 and TM2410CCU
Flush/Surface Bottom TLK20 (order separately)
Front
100 20 10 0 0 20 Combination Top 6 4-1/0 TGK24 (order separately) TM2010CCU
Flush/Surface Bottom
Front
100 32 16 0 0 32 Combination Top 11 4-1/0 TGK32 (order separately) TM3210CCU
Flush/Surface Bottom
Front
125 12 5 20 8 22 Combination Top 18 1-2/0 Included1 TM1212CCU2
Flush/Surface Bottom
Front
125 24 12 0 0 24 Combination Top 7 1-2/0 TGK24 (order separately) TM2412CCU
Flush/Surface Bottom
Front
125 16 8 16 6 24 Combination Top 4 1-2/0 TGK12 (order separately) TM1612CCU
Flush/Surface Bottom TGK24 (order separately)
Front
125 16 8 16 6 24 Combination Top 4 1-2/0 TGK24 installed TM1612CCUG
Flush/Surface Bottom
Front
150 16 8 32 14 32 Combination Top 7 1-3/0 (Cu), TGK24 (order separately) TM1615CCU
Flush/Surface Bottom 2/0-3/0 (Al) TGK32 (order separately)
Front
150 16 8 32 14 32 Combination Top 7 1-3/0 (Cu), TGK32 installed TM1615CCUG
Flush/Surface Bottom 2/0-3/0 (Al)
Front
This table continued on next page

1-12 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Page Updated 01 / 2017

Load Centers and Circuit Breakers Section 1


PowerMark Gold and Plus Main Breaker Load Centers Load Center
1PH
Single-Phase, Three-Wire, 120/240 Vac Main Breaker
Main Breaker Factory Installed Indoor NEMA 1

Indoor (NEMA 1) Enclosure


Main 1 Pole, 2 Pole, 1 Pole, 2 Pole, Total Main Wire Size
Ampere 1 1 1/2 1/2 1-pole Front Feed Box (AWG/kcmil) Equipment Product
Rating Spaces Spaces Spaces Spaces Spaces Type Type Number Cu-Al Ground Kit Number
150 32 16 0 0 32 Combination Top 11 1-3/0 (Cu), TGK32 (order separately) TM3215CCU
Flush/Surface Bottom 2/0-3/0 (Al)
150 24 12 36 18 42 Combination Top 9 1-3/0 (Cu), TGK24 (order separately) TM2415C42
Flush/Surface Bottom 2/0-3/0 (Al) TLK32 (order separately)
150 32 16 20 10 42 Combination Top 11 1-3/0 (Cu), TGK32 and TLK20 TM3215C42
Flush/Surface Bottom 2/0-3/0 (Al) (order separately)
200 16 8 32 14 32 Combination Top 7 1-250 (Cu), TGK32 (order separately) TM1620CCU
Flush/Surface Bottom 2/0-250 (Al)
200 16 8 32 14 32 Combination Top 8 1-250 (Cu), TGK32 installed TM1620CCUG
Flush/Surface Bottom 2/0-250 (Al)
200 20 10 40 18 40 Combination Top 8 1-250 (Cu), TGK32 (order separately) TM2020CCU
Flush/Surface Bottom 2/0-250 (Al)
200 20 10 40 18 40 White Combo Top 8 1-250 (Cu), TGK24 (order separately) TM2020CCUW3
Flush/Surface Bottom 2/0-250 (Al) TGK42 (order separately)
200 20 10 40 18 40 Combination Top 8 1-250 (Cu), TGK32 (order separately) TM2020CCUG
Flush/Surface Bottom 2/0-250 (Al)
200 20 10 40 18 40 White Combo Top 8 1-250 (Cu), TGK32 (order separately) TM2020CCUGW3
Flush/Surface Bottom 2/0-250 (Al)
200 32 16 16 6 40 Combination Top 11 1-250 (Cu), TGK32 (order separately) TM3220CCU
Flush/Surface Bottom 2/0-250 (Al)
200 40 20 0 0 40 Combination Top 13 1-250 (Cu), TGK42 (order separately) TM4020CCU
Flush/Surface Bottom 2/0-250 (Al)
200 32 16 20 8 42 Combination Top 11 1-250 (Cu), TGK32 and TLK20 TM3220C42
Flush/Surface Bottom 2/0-250 (Al) (order separately)
200 42 20 0 0 42 Combination Top 14 1-300 (Cu), TGK42 (order separately) TM4220CCU
Flush/Surface Bottom 2/0-300 (Al)
225 42 20 0 0 42 Combination Top 14 1-300 (Cu), TGK42 (order separately) TM4222CCU
Flush/Surface Bottom 2/0-300 (Al)
1Load center includes a factory installed ground bar and add-a-lug. See wiring diagram on page 1-31. A separate TGL2 can be added in the unlikey event
that another ground bar is required.
2No lock provision available. Use next size larger load center such as TLM1612CCU with a TDL106 accessory if locking provision is required.
3Minimum order QTY is 40 for below 24 circuits; QTY 24 for 24 circuits and above. (See DEE-590)

Load Center
1PH
Main Breaker
Outdoor NEMA 3R
Outdoor (NEMA 3R) Enclosure4
Main 1 Pole, 2 Pole, 1 Pole, 2 Pole, Total Main Wire Size
Ampere 1 1 1/2 1/2 1-pole Feed Box (AWG/kcmil) Equipment Product
Rating Spaces Spaces Spaces Spaces Spaces Type Number Cu-Al Ground Kit Number
100 12 5 20 8 22 Top R3A 4-1/0 TGK12 (order separately) TM1210RCU
TGK24 (order separately)
100 20 10 0 0 30 Top R4 4-1/0 TGK24 (order separately) TM2010RCU
125 12 5 20 8 22 Top R3A 1-2/0 TGK12 (order separately) TM1212RCU
TGK24 (order separately)
125 24 12 0 0 24 Top R4 1-2/0 TGK24 (order separately) TM2412RCU
150 8 4 16 6 16 Top R5 1-250 (Cu), 2/0-250 (Al) TGK24 (order separately) TM815RCUFL
150 16 8 32 14 32 Top R5 1-3/0 (Cu), 2/0-3/0 (Al) TGK24 (order separately) TM1615RCU
TGK32 (order separately)
150 24 12 12 4 30 Top R6 1-3/0 (Cu), 2/0-3/0 (Al) TGK24 (order separately) TM2415RCU
TGK32 (order separately)
150 24 12 36 18 42 Top R39 1-250 (Cu), 2/0-250 (Al) TGK24 (order separately) TM2415R42
Bottom
150 32 16 0 0 32 Top R7 1-3/0 (Cu), 2/0-3/0 (Al) TGK32 (order separately) TM3215RCU
200 8 4 16 6 16 Top R5 1-250 (Cu), 2/0-250 (Al) TGK32 (order separately) TM820RCUFL
200 20 10 40 18 40 Top R6 1-250 (Cu), 2/0-250 (Al) TGK24 (order separately) TM2020RCU
TGK42 (order separately)
200 24 12 36 18 42 Top R39 1-250 (Cu), 2/0-250 (Al) TGK24 (order separately) TM2420R42
Bottom
200 32 16 16 6 40 Top R7 1-250 (Cu), 2/0-250 (Al) TGK32 (order separately) TM3220RCU
200 40 20 0 0 40 Top R8 1-250 (Cu), 2/0-250 (Al) TGK42 (order separately) TM4020RCU
225 8 4 16 6 16 Top R5 1-250 (Cu), 2/0-250 (Al) TGK24 (order separately) TM822RCUFL
225 42 20 0 0 42 Top R8 1-300 (Cu), 2/0-300 (Al) TGK42 (order separately) TM4222RCU
4100-225 amp devices have removable closing caps. Larger ampere devices require field-cut openings. Order hubs separately. See page 1-27.

Note: See page 11-4, AL Series Lighting Panelboards as replacements for 300-600A load centers.

Rev. 11/13 www.geindustrial.com BuyLog Catalog 1-13


Data subject to change
without notice
Load Centers and Circuit Breakers Section 1
Load Center
PowerMark Plus Load Centers 3PH
Three-Phase, Four-Wire, 208Y/120 Vac2 Main Lugs
Main Lugs Factory Installed Indoor NEMA 1

Product Features
UL Listed (Panelboards No. 67)
60/75C Conductor Rating
Suitable for Use as Service Entrance Equipment when Installed
in Accordance with the National Electrical Code
22kAIC RMS symmetrical Short-circuit Rating Standard
Bottom feed models available where noted with a B suffix.
For a listing of CSA Listed load centers, visit geindustrial.com.
Copper breaker mounting stabs with aluminum bus1

Indoor (NEMA 1) Enclosure


Main 1 Pole, 2 Pole, 3 Pole, Total Main Wire Size
Ampere 1 1 1 1-pole Feed Box (AWG/kcmil) Equipment Product
Rating Spaces Spaces Spaces Spaces Front Type Type Number Cu-Al Ground Kit Number
125 12 6 4 12 Combination Top 4 6-2/0 TGK12 (order separately) TL12412C3
Flush/Surface Bottom TGK24 (order separately)
Front
150 18 8 6 18 Combination Top 7 1-3/0 (Cu), TGK24 (order separately) TL18415C3
Flush/Surface Bottom 2/0-3/0 (Al) TGK32 (order separately)
Front
150 24 12 8 24 Combination Top 7 1-3/0 (Cu), TGK24 (order separately) TL24415C3
Flush/Surface Bottom 2/0-3/0 (Al) TGK32 (order separately)
Front
200 18 8 6 18 Combination Top 8 1-250 (Cu), TGK32 (order separately) TL18420C3
Flush/Surface Bottom 2/0-250 (Al)
Front
200 30 14 10 30 Combination Top 11 1-250 (Cu), TGK32 (order separately) TL30420C3
Flush/Surface Bottom 2/0-250 (Al)
Front
200 42 20 14 42 Combination Top 13 1-250 (Cu), TGK42 (order separately) TL42420C
Flush/Surface Bottom 2/0-250 (Al)
Front
225 30 14 10 30 Combination Top 15 1-300 (Cu), (2) TGL2 (order separately) TL30422C4
Flush/Surface Bottom 2/0-300 (Al)
Front
225 42 20 14 42 Combination Top 15 1-300 (Cu), (2) TGL2 (order separately) TL42422C4
Flush/Surface Bottom 2/0-300 (Al)
Front
1Three-phase PowerMark Plus load centers have aluminum bus with copper breaker mounting stabs, providing copper-to-copper contact at breaker stabs.
2Also UL Listed for three-phase, four-wire 240/120 Volts ac delta and three-phase, three-wire 240 Volts ac branch breakers installed.
3Alternate main breaker: 100 Amp max. THQL (10kAIC), THHQL (22kAIC) three-pole, use retainer THQLRK. See page 1-28.
4Not suitable for use as service entrance equipment.

Note: See page 11-4, AL Series Lighting Panelboards as replacements for 300-600A load centers.

1-14 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Load Centers and Circuit Breakers Section 1
Load Center
PowerMark Plus Load Centers 3PH
Three-Phase, Four-Wire, 208Y/120Vac Main Lugs
Main Circuit Breaker or Main Lugs Factory Installed Outdoor NEMA 3R

Main Lugs Factory Installed1 TM24420CB


Outdoor (NEMA 3R) Enclosure
Main 1 Pole, 2 Pole, 3 Pole, Total Main Wire Size
Ampere 1 1 1 1-pole Feed Box (AWG/kcmil) Equipment Product
Rating Spaces Spaces Spaces Spaces Type Number Cu-Al Ground Kit Number
125 12 6 4 12 Top R3 6-2/0 TGK12 (order separately) TL12412R2
TGK24 (order separately)
150 18 8 6 18 Top R4 1-3/0 (Cu), TGK24 (order separately) TL18415R2
2/0-3/0 (Al) TGK32 (order separately)
150 24 12 8 24 Top R4 1-3/0 (Cu), TGK24 (order separately) TL24415R2
2/0-3/0 (Al) TGK32 (order separately)
200 18 8 6 18 Top R4 1-250 (Cu), TGK32 (order separately) TL18420R2
2/0-250 (Al)
200 30 14 10 30 Top R6 1-250 (Cu), TGK32 (order separately) TL30420R2
2/0-250 (Al)
200 42 20 14 42 Top R8 1-250 (Cu), TGK42 (order separately) TL42420R3
2/0-250 (Al)
225 42 20 14 42 Top R8 1-300 (Cu), TGK42 (order separately) TL42422R3
2/0-300 (Al)
1Also UL Listed for three-phase, four-wire 240/120 Volts ac delta and three-phase, three-wire 240 Volts ac branch breakers installed.
2Alternate main breaker 100 Amp max. THQL (10kAIC), THHQL (22kAIC) three-pole, use retainer THQLRK. See page 1-28.
3Not suitable for use as service entrance equipment.
Load Center
3PH
Main Breaker
Main Breaker Factory Installed4 Indoor NEMA 1
Indoor (NEMA 1) Enclosure
Main 1 Pole, 2 Pole, 3 Pole, Total Main Wire Size
Ampere 1 1 1 1-pole Feed Box (AWG/kcmil) Equipment Product
Rating Spaces Spaces Spaces Spaces Front Type Type Number Cu-Al Ground Kit Number
100 12 6 4 12 Combination Top 6 6-1/0 (Cu), TGK12 (order separately) TM12410C5
Flush/Surface Bottom 4-1/0 (Al) TGK24 (order separately)
Front
100 18 8 6 18 Combination Top 6 6-1/0 (Cu), TGK24 (order separately) TM18410C5
Flush/Surface Bottom 4-1/0 (Al) TGK32 (order separately)
Front
125 30 14 10 30 Combination Top 11 1-3/0 (Cu), TGK32 (order separately) TM30412C
Flush/Surface 2/0-3/0 (Al)
Front
125 30 14 10 30 Combination Bottom 11 1-3/0 (Cu), TGK32 (order separately) TM30412CB
Flush/Surface 2/0-3/0 (Al)
Front
150 24 12 8 24 Combination Top 11 1-3/0 (Cu), TGL1, TGL2, TGL20,TNG3, TM24415C
Flush/Surface 2/0-3/0 (Al TGN6 (order separately)
Front
150 24 12 8 24 Combination Bottom 11 1-3/0 (Cu), TGK32 (order separately) TM24415CB
Flush/Surface 2/0-3/0 (Al)
Front
150 30 14 10 30 Combination Top 11 1-3/0 (Cu), TGK32 (order separately) TM30415C
Flush/Surface 2/0-3/0 (Al)
Front
150 30 14 10 30 Combination Bottom 11 1-3/0 (Cu), TGK32 (order separately) TM30415CB
Flush/Surface 2/0-3/0 (Al)
Front
150 42 20 14 42 Combination Top 13 1-3/0 (Cu), TGK42 (order separately) TM42415C
Flush/Surface 2/0-3/0 (Al)
Front
150 42 20 14 42 Combination Bottom 13 1-3/0 (Cu), TGK42 (order separately) TM42415CB
Flush/Surface 2/0-3/0 (Al)
Front
200 24 12 8 24 Combination Top 11 1-300 (Cu), TGK32 (order separately) TM24420C
Flush/Surface 2/0-300 (Al)
Front
200 24 12 8 24 Combination Bottom 11 1-300 (Cu), TGK32 (order separately) TM24420CB
Flush/Surface 2/0-300 (Al)
Front
4Also UL Listed for three-phase, four-wire 240/120 Volts Hi leg delta and three-phase, three-wire 240 Volts ac branch breakers installed.
5100 Amp indoor devices UL listed for bottom-feed by installing complete unit upside-down.

Note: See page 11-4, AL Series Lighting Panelboards as replacements for 300-600A load centers. This table continued on next page

Rev. 11/13 www.geindustrial.com BuyLog Catalog 1-15


Data subject to change
without notice
Load Centers and Circuit Breakers Section 1
Load Center
PowerMark Plus Load Centers 3PH
Three-Phase, Four-Wire, 208Y/120 Vac1 Main Breaker
Main Circuit Breaker Factory Installed Indoor NEMA 1

Indoor (NEMA 1) Enclosure


Main 1 Pole, 2 Pole, 3 Pole, Total Main Wire Size
Ampere 1 1 1 1-pole Feed Box (AWG/kcmil) Equipment Product
Rating Spaces Spaces Spaces Spaces Front Type Type Number Cu-Al Ground Kit Number
200 30 14 10 30 Combination Top 12 1-250 (Cu), TGK32 (order separately) TM30420C
Flush/Surface 2/0-250 (Al)
Front
200 30 14 10 30 Combination Bottom 12 1-250 (Cu), TGK32 (order separately) TM30420CB
Flush/Surface 2/0-250 (Al)
Front
200 42 20 14 42 Combination Top 14 1-250 (Cu), TGK42 (order separately) TM42420C
Flush/Surface 2/0-250 (Al)
Front
200 42 20 14 42 Combination Bottom 14 1-250 (Cu), TGK42 (order separately) TM42420CB
Flush/Surface 2/0-250 (Al)
Front
225 42 20 14 42 Combination Top 15 1-300 (Cu), (2) TGL2 (order separately) TM42422C
Flush/Surface 2/0-300 (Al)
Front
225 42 20 14 42 Combination Bottom 15 1-300 (Cu), (2) TGL2 (order separately) TM42422CB
Flush/Surface 2/0-300 (Al)
Front
1Also UL Listed for three-phase, four-wire 240/120 Volts Hi leg delta and three-phase, three-wire 240 Volts ac branch breakers installed.

Load Center
3PH
Main Breaker
Outdoor NEMA 3R
Outdoor (NEMA 3R) Enclosure
Main 1 Pole, 2 Pole, 3 Pole, Total Main Wire Size
Ampere 1 1 1 1-pole Feed Box (AWG/kcmil) Equipment Product
Rating Spaces Spaces Spaces Spaces Type Number Cu-Al Ground Kit Number
100 18 8 6 18 Top R4 6-1/0 (Cu), TGK24 (order separately) TM18410R
4-1/0 (Al) TGK32 (order separately)
125 30 14 10 30 Top R7 1-3/0 (Cu), TGK32 (order separately) TM30412R
2/0-3/0 (Al)
150 24 12 8 24 Top R6 1-3/0 (Cu), TGK32 (order separately) TM24415R
2/0-3/0 (Al)
150 30 14 10 30 Top R7 1-3/0 (Cu), TGK32 (order separately) TM30415R
2/0-3/0 (Al)
200 30 14 10 30 Top R7 1-250 (Cu), TGK32 (order separately) TM30420R
2/0-250 (Al)
200 42 20 14 42 Top R8 1-250 (Cu), TGK42 (order separately) TM42420R
2/0-250 (Al)
225 42 20 14 42 Top R8 1-300 (Cu), TGK42 (order separately) TM42422R
2/0-300 (Al)

Note: See page 11-4, AL Series Lighting Panelboards as replacements for 300-600A load centers.

1-16 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Page Updated 01 / 2017

Load Centers and Circuit Breakers Section 1


Load Center
PowerMark Gold Load Centers Generator Panels
Single-Phase, Three-Wire, 120/240 Vac Riser Panels
Spa Panels

Product Features - Generator Panels


Suitable for use in accordance with Article 702 of the National
Electrical Code, ANSI/NFPA 70
Single-phase, 2 interlock 60A or 30A main breakers, 8 circuits
max.
Safety and convenience when using a generator - 14,000 peak
wattage, 11,520 continuous load, 48 amps at 240 volts.
Maintains power to such critical circuits as those for furnace,
pump, refrigerator, lights.
Connected dual breaker mechanism ensures that only one TL412R250GF TM830FCUGEN
source is active at a time.

Generator Panels, Two Interlocked Main Breakers Factory Installed


Indoor (NEMA 1) Enclosure
Main 1 Pole, 2 Pole, 1 Pole, 2 Pole, Total Main Wire Size
Ampere 1 1 1/2 1/2 1-pole Feed Box (AWG/kcmil) Equipment Product
Rating Spaces Spaces Spaces Spaces Spaces Front Type Type Number Cu-Al Ground Kit Number
30 4 2 8 4 8 Flush Front Top 3A 6-1 TGK12 included TM830FCUGEN
Bottom
30 4 2 8 4 8 Surface Front Top 3A 6-1 TGK12 included TM830SCUGEN
Bottom
60 4 2 8 4 8 Flush Front Top 3A 6-1 TGK12 included TM860FCUGEN
Bottom
60 4 2 8 4 8 Surface Front Top 3A 6-1 TGK12 included TM860SCUGEN
Bottom

Generator Panels, Two Interlocked Main Breakers Factory Installed


Outdoor (NEMA 3R) Enclosure
Main 1 Pole, 2 Pole, 1 Pole, 2 Pole, Total Main Wire Size
Ampere 1 1 1/2 1/2 1-pole Feed Box (AWG/kcmil) Equipment Product
Rating Spaces Spaces Spaces Spaces Spaces Type Number Cu-Al Ground Kit Number
30 4 2 8 4 8 Top R2A 6-1 TGK12 included TM830RCUGEN
60 4 2 8 4 8 Top R2A 6-1 TGK12 included TM860RCUGEN

Riser Panels
Indoor (NEMA 1) Enclosure
Main 1 Pole, 2 Pole, 1 Pole, 2 Pole, Total Main Wire Size
Ampere 1 1 1/2 1/2 1-pole Feed Box (AWG/kcmil) Equipment Product
Rating Spaces Spaces Spaces Spaces Spaces Front Type Type Number Cu-Al Ground Kit Number
125 20 10 40 20 40 Combination Top 9A 6-2/0 TGK12 (order TLM2012CCURP
Flush/Surface Front separately)

Tap kits required, order separately. See page 1-30.


Auxiliary gutters available. See page 1-30.

Spa Panels
Outdoor (NEMA 3R) Enclosure
Main 1 Pole, 2 Pole, 1 Pole, 2 Pole, Total Main Wire Size
Ampere 1 1 1/2 1/2 1-pole Load Center Feed Box (AWG/kcmil) Equipment Product
Rating Spaces Spaces Spaces Spaces Spaces Type Type Number Cu-Al Ground Kit Number
125 4 2 8 4 8 Factory Included Top 1-2/0 TGL1 installed TL412R250GF
50A GFCI Bottom
125 4 2 8 4 8 Factory Included Top 1-2/0 TGL1 installed TL412R260GF
60A GFCI Bottom

Twist Lock Power Inlets


Product
Receptacles Amps Volts UL Number
L14-20 20 120/240 Canada, US T020N
L14-30 30 120/240 Canada, US T030N
CS637 50 120/240 Canada, US T050N

Rev. 11/13 www.geindustrial.com BuyLog Catalog 1-17


Data subject to change
without notice
Page Updated 01 / 2017

Load Centers and Circuit Breakers Section 1


Meter Socket LC
PowerMark Gold Meter Socket Load Centers 1PH
Single-Phase, Three-Wire, 120/240 Vac Ring Type
With Bonded Neutrals Meter Main
NEMA 3R

Designed and manufactured for quality applications, these


PowerMark Gold Meter Socket Load Centers are a superior
solution to specific applications. Increased durability and
reliability, maximum circuit layout flexibility and ease of
installation add up to lower total installed cost.
UL Listed (Panelboards No. UL67)
Service Barriers included for factory installed main circuit
breaker and main circuit breaker kits (required to meet UL67
for service entrance applications)

The Ringless UL Style meter socket load centers (Florida Meter


Group, Georgia Power, Others) are specifically designed to meet TSM2020CFCU
UL requirements as well as some special features required by spe-
cific utilities. If your local utility does not require specific approval
and you need a ringless meter socket load center, use the Florida
Meter Group style.

Main
Ampere 1 Pole, 2 Pole, 1 Pole, 2 Pole, Total 1-pole Enclosure Bypass UL Agency Product
Rating 1 Spaces 1 Spaces 1/2 Spaces 1/2 Spaces Spaces Type Front Type Type Incoming Certification Number

Meter Main - Ring Type, Field Installed Mains


100 2 1 4 1 4 Outdoor Semi-Flush None OH/UG UL TSL210CFCU1
(NEMA 3R) EUSERC
100 2 1 4 1 4 Outdoor Surface2 None OH/UG UL TSL210CSCU1,2,3
(NEMA 3R) EUSERC
125 4 2 6 3 6 Outdoor Surface2 None OH/UG UL TSL412CSCU1,2,3
(NEMA 3R) EUSERC
200 4 2 6 3 6 Outdoor Semi-Flush None OH/UG UL TSL420CFCU1,4,5
(NEMA 3R) EUSERC
200 4 2 6 3 6 Outdoor Surface2 None OH/UG UL TSL420CSCU1,2,3,4
(NEMA 3R) EUSERC

Meter Main - Factory Installed Mains


100 0 0 0 0 0 Outdoor Surface2 None OH/UG UL TM10RMC2
(NEMA 3R)
125 0 0 0 0 0 Outdoor Surface2 None OH/UG UL TM12RMC2
(NEMA 3R)
150 0 0 0 0 0 Outdoor Surface2 None OH/UG UL TM15RMC2
(NEMA 3R)
200 0 0 0 0 0 Outdoor Surface2 None OH/UG UL TM20RMC2
(NEMA 3R)
1Accepts field installed fifth jaw terminal in the 3 or 9 oclock position. Product number TJAW53; order separately.
2Devices include removable closing cap. Order hub separately. See page 1-27.
3Surface mounted units have two hub provisions on top end wall.
4THQL and THHQL only, 125 amp max. TQDL is obsolete.
5Restricted

Application Data
Main Wire Size
Product Box Unit Width Unit Height Depth Factory Inst. Field Inst. (AWG/kcmil) Equipment
Number Number (in inches) (in inches) (in inches) Svcs Disc Svcs Disc Cu-Al Ground Kit
TSL210CFCU R12 14 23-1/2 4-7/8 THQP/THQL 6-2/0 TGL1 installed
TSL210CSCU R12 14 23-1/2 4-7/8 THQP/THQL 6-2/0 TGL1 installed
TSL412CSCU R12 14 23-1/2 4-7/8 THQP/THQL 6-2/0 TGL1 installed
TSL420CFCU R14 14 30-3/4 5-3/4 THQP/THQL 1-250 TGL1 installed
TSL420CSCU R14 14 30-3/4 5-3/4 THQP/THQL 1-250 TGL1 installed
TM10RMC R32 16 17 5 TQD Field Installed4 2-250
TM12RMC R32 16 17 5 TQD Field Installed4 2-250
TM15RMC R32 16 17 5 TQD Field Installed4 2-250
TM20RMC R32 16 17 5 TQD Field Installed4 2-250

1-18 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Page Updated 01 / 2017

Load Centers and Circuit Breakers Section 1


Meter Socket LC
PowerMark Gold Meter Socket Load Centers 1PH
Single-Phase, Three-Wire, 120/240 Vac Ring Type
With Bonded Neutrals Farm Panel
Main Breaker
NEMA 3R
Ring Type - Farm Panel - Main Breaker
Main
Ampere 1 Pole, 2 Pole, 1 Pole, 2 Pole, Total 1-pole Enclosure Front Bypass UL Agency Product
Rating 1 Spaces 1 Spaces 1/2 Spaces 1/2 Spaces Spaces Type Front Type Type Incoming Certification Number
200 4 2 8 3 8 Outdoor Surface None OH/UG UL TSF420CSCU1,2
(NEMA 3R) EUSERC
1Devices include removable closing cap. Order hub separately. See page 1-27.
2Separate field mounted service disconnect can be added, THQL/THHQL. See wiring diagram on page 1-36.

Application Data
Main Wire Size
Product Box Unit Width Unit Height Depth Factory Inst. Field Inst. (AWG/kcmil) Equipment
Number Number (in inches) (in inches) (in inches) Svcs Disc Svcs Disc Cu-Al Ground Kit
TSF420CSCU R16 16-3/4 33 6-3/16 THQMV THQL/THHQL 1-300 TGK12 (order separately)

Ring Type Feed-Thru - Main Breaker


Main
Ampere 1 Pole, 2 Pole, 1 Pole, 2 Pole, Total 1-pole Enclosure Front Bypass UL Agency Product
Rating 1 Spaces 1 Spaces 1/2 Spaces 1/2 Spaces Spaces Type Type Type Incoming Certification Number
150 4 2 8 3 8 Outdoor Surface None OH/UG UL TSM415CSCU1
(NEMA 3R
150 8 4 16 6 16 Outdoor Surface None OH/UG UL TSM815CSCU1
(NEMA 3R)
150 8 4 16 6 16 Outdoor Surface None OH/UG UL TSM815CSFL1
(NEMA 3R)
200 4 2 8 3 8 Outdoor Surface None OH/UG UL TSM420CSCU1
(NEMA 3R)
200 8 4 16 6 16 Outdoor Surface None OH/UG UL TSM820CSCU1
(NEMA 3R
200 8 4 16 6 16 Outdoor Surface None OH/UG UL TSM820CSFL1
(NEMA 3R)
1Devices include removable closing cap. Order hub separately. See page 1-27.

Application Data
Main Wire Size
Product Box Unit Width Unit Height Depth Factory Inst. (AWG/kcmil) Equipment
Number Number (in inches) (in inches) (in inches) Svcs Disc Cu-Al Ground Kit
TSM415CSCU R36 14 28-1/2 4-1/2 THQMV 6-350 TGL2 included
TSM815CSCU R16 16-3/4 33 6-3/16 THQMV 1-300 TGK12 (order separately)
TSM815CSFL R37B 14 31-3/4 4-1/2 THQMV 6-350 TGK24 included
TSM420CSCU R36 14 28-1/2 4-1/2 THQMV 6-350 TGL2 included
TSM820CSCU R16 16-3/4 33 6-3/16 THQMV 6-350 TGK12 (order separately)
TSM820CSFL R37B 14 31-3/4 4-1/2 THQMV 6-350 TGK24 included

Rev. 11/13 www.geindustrial.com BuyLog Catalog 1-19


Data subject to change
without notice
Load Centers and Circuit Breakers Section 1
Meter Socket LC
PowerMark Gold Meter Socket Load Centers 1PH
Single-Phase, Three-Wire, 120/240 Vac Ring Type
With Bonded Neutrals Narrow, Wide, Over/Under
Main Breaker
NEMA 3R
Ring Type - Side by Side - Main Breaker - OH/UG
Main
Ampere 1 Pole, 2 Pole, 1 Pole, 2 Pole, Total 1-pole Enclosure Bypass UL Agency Product
Rating 1 Spaces 1 Spaces 1/2 Spaces 1/2 Spaces Spaces Type Front Type Type Incoming Certification Number
100 16 8 32 14 32 Outdoor Semi-Flush None OH/UG UL/EUSERC TSM1610CFCU1
125 12 6 24 12 24 Outdoor Semi-Flush None OH/UG UL/EUSERC TSM1212CFCU1
125 16 8 32 14 32 Outdoor Semi-Flush None OH/UG UL/EUSERC TSM1612CFCU1
200 20 10 40 18 40 Outdoor Semi-Flush None OH/UG UL/EUSERC TSM2020CFCU1
100 16 8 32 14 32 Outdoor Surface None OH/UG UL/EUSERC TSM1610CSCU1,2,3
125 12 6 24 12 24 Outdoor Surface None OH/UG UL/EUSERC TSM1212CSCU1,2,3
125 16 8 32 14 32 Outdoor Surface None OH/UG UL/EUSERC TSM1612CSCU1,2,3
200 20 10 40 18 40 Outdoor Surface None OH/UG UL/EUSERC TSM2020CSCU1,2,3
1Accepts field installed fifth jaw terminal in the 3 or 9 oclock position. Product number TJAW53; order separately.
2Devices include removable closing cap. Order hub separately. See page 1-27.
3Surface mounted units have two hub provisions on top end wall.

Application Data
Main Wire Size
Box Unit Width Unit Height Depth Factory Inst. (AWG/kcmil) Equipment
Product Number Number (in inches) (in inches) (in inches) Svcs Disc Cu-Al Ground Kit
TSM1610CFCU R19 14-3/4 28-1/2 7-5/16 THHQL 12-2/0 TGK12 (order separately)
TSM1212CFCU R19 14-3/4 28-1/2 7-5/16 THHQL 12-2/0 TGK12 (order separately)
TSM1612CFCU R19 14-3/4 28-1/2 7-5/16 THHQL 12-2/0 TGK12 (order separately)
TSM2020CFCU R17 16-3/4 34-1/4 7-5/16 THQMV 1-300 TGK12 (order separately)
TSM1610CSCU R20 14-3/4 27-5/16 5-7/16 THHQL 12-2/0 TGK12 (order separately)
TSM1212CSCU R20 14-3/4 27-5/16 5-7/16 THHQL 12-2/0 TGK12 (order separately)
TSM1612CSCU R20 14-3/4 27-5/16 5-7/16 THHQL 12-2/0 TGK12 (order separately)
TSM2020CSCU R18 14-3/4 33 6-5/16 THQMV 1-300 TGK12 (order separately)

Ring Type - Extra Wide - Main Breaker


Main
Ampere 1 Pole, 2 Pole, 1 Pole, 2 Pole, Total 1-pole Enclosure Bypass UL Agency Product
Rating 1 Spaces 1 Spaces 1/2 Spaces 1/2 Spaces Spaces Type Front Type Type Incoming Certification Number
200 32 16 16 6 40 Outdoor Surface None UG UL/EUSERC TSM3220UWCU2
200 40 20 0 0 40 Outdoor Surface None UG UL/EUSERC TSM4020UWCU2
2Devices include removable closing cap. Order hub separately. See page 1-27.

Application Data
Main Wire Size
Box Unit Width Unit Height Depth Factory Inst. (AWG/kcmil) Equipment
Product Number Number (in inches) (in inches) (in inches) Svcs Disc Cu-Al Ground Kit
TSM3220UWCU R28 22-1/2 27-7/8 6-1/4 THQMV 1-300 TGK12 (order separately)
TSM4020UWCU R29 22-1/2 34-7/8 6-1/4 THQMV 1-300 TGK12 (order separately)

Ring Type - Top/Bottom - Main Breaker


Main
Ampere 1 Pole, 2 Pole, 1 Pole, 2 Pole, Total 1-pole Enclosure Bypass UL Agency Product
Rating 1 Spaces 1 Spaces 1/2 Spaces 1/2 Spaces Spaces Type Front Type Type Incoming Certification Number
200 24 12 36 18 42 Outdoor Semi-Flush None UG UL/EUSERC TSM2420UF421
200 32 14 16 6 40 Outdoor Semi-Flush None UG UL/EUSERC TSM3220UFCU
225 20 10 40 18 40 Outdoor Semi-Flush None UG UL/EUSERC TSM2022UFCU
225 32 14 16 6 40 Outdoor Semi-Flush None UG UL/EUSERC TSM3222UFCU
200 24 12 36 18 42 Outdoor Surface None UG UL/EUSERC TSM2420US421,2,3
200 32 14 16 6 40 Outdoor Surface None UG UL/EUSERC TSM3220USCU1
225 20 10 40 18 40 Outdoor Surface None UG UL/EUSERC TSM2022USCU1
225 32 14 16 6 40 Outdoor Surface None UG UL/EUSERC TSM3222USCU1
1Accepts field installed fifth jaw terminal in the 3 or 9 oclock position. Product number TJAW53; order separately.
2Devices include removable closing cap. Order hub separately. See page 1-27.
3Surface mounted units have two hub provisions on top end wall.

Application Data
Main Wire Size
Box Unit Width Unit Height Depth Factory Inst. (AWG/kcmil) Equipment
Product Number Number (in inches) (in inches) (in inches) Svcs Disc Cu-Al Ground Kit
TSM2420UF42 R17 16-3/4 34-1/4 7-5/16 THQMV 1-4/0 TGK12 (order separately)
TSM3220UFCU R27 14-9/16 43-5/8 7-3/16 THQMV 1-300 TGK12 (order separately)
TSM2022UFCU R21 14-9/16 43-5/8 7-3/16 THQMV 1-300 TGK12 (order separately)
TSM3222UFCU R22 16-3/16 48-1/8 7-3/16 THQMV 1-300 TGK12 (order separately)
TSM2420US42 R17 16-3/4 34-1/4 7-5/16 THQMV 1-4/0 TGK12 (order separately)
TSM3220USCU R27 14-9/16 48-1/8 6-3/16 THQMV 1-300 TGK12 (order separately)
TSM2022USCU R26 14-9/16 43-5/8 6-3/16 THQMV 1-300 TGK12 (order separately)
TSM3222USCU R27 14-9/16 48-1/8 6-3/16 THQMV 1-300 TGK12 (order separately)

1-20 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Load Centers and Circuit Breakers Section 1
Meter Socket LC
PowerMark Gold Meter Socket Load Centers 1PH
Single-Phase, Three-Wire, 120/240 Vac Ringless with Bypass
With Bonded Neutrals Xcel Energy
NEMA 3R

Ringless with Bypass - Xcel Energy


Main
Ampere 1 Pole, 2 Pole, 1 Pole, 2 Pole, Total 1-pole Enclosure Main Bypass UL Agency Product
Rating 1 Spaces 1 Spaces 1/2 Spaces 1/2 Spaces Spaces Type Type Front Type Type Incoming Certification Number
125 4 2 8 3 8 Outdoor MLO Surface Horn Bypass OH/UG Xcel/UL TSLR412CSCU1
(NEMA 3R)
125 4 2 6 3 6 Outdoor MLO Surface1 Lever OH/UG Xcel/UL TSLB412CSCU1
(NEMA 3R) Bypass
125 12 6 24 10 24 Outdoor MB Surface Horn Bypass OH/UG Xcel/UL TSMR1212CSCU1
(NEMA 3R)
125 12 6 24 12 24 Outdoor MB Surface Lever OH/UG Xcel/UL TSMB1212CSCU1
(NEMA 3R) Bypass
150 4 2 8 3 8 Outdoor MB Surface Horn Bypass OH/UG Xcel/UL TSMR415CSCU
(NEMA 3R)
150 20 10 40 18 40 Outdoor MB Surface Horn Bypass OH/UG Xcel/UL TSMR2015CSCU1
(NEMA 3R)
150 20 10 40 18 40 Outdoor MB Surface Lever OH/UG Xcel/UL TSMB2015CSCU1
(NEMA 3R) Bypass
200 4 2 6 3 6 Outdoor MLO Surface1 Lever OH/UG Xcel/UL TSLB420CSCU1
(NEMA 3R) Bypass
200 4 2 8 3 8 Outdoor MLO Surface Horn Bypass OH/UG Xcel/UL TSLR420CSCU1
(NEMA 3R)
200 4 2 8 3 8 Outdoor MB Surface Horn Bypass OH/UG Xcel/UL TSMR420CSCU
(NEMA 3R)
200 20 10 40 18 40 Outdoor MB Surface Horn Bypass OH/UG Xcel/UL TSMR2020CSCU1
(NEMA 3R)
200 20 10 40 18 40 Outdoor MB Surface Lever OH/UG Xcel/UL TSMB2020CSCU1
(NEMA 3R) Bypass
1Devices include removable closing cap. Order hub separately. See page 1-27.

Application Data
Main Wire Size
Box Unit Width Unit Height Depth Factory Inst. (AWG/kcmil) Equipment
Product Number Number (in inches) (in inches) (in inches) Svcs Disc Cu-Al Ground Kit
TSLR412CSCU R31 14-9/16 33-9/16 6-3/16 Field Installed2 6-350 TGK12 (order separately)
TSLB412CSCU R12 14 23-1/2 4-7/8 Field Installed2 6-350 TGL1 installed
TSMR1212CSCU R30 14-9/16 40-1/2 6-3/16 THHQL 6-350 TGK12 (order separately)
TSMB1212CSCU R20 14-3/4 27-5/16 5-7/16 THHQL 12-2/0 TGK12 (order separately)
TSMR415CSCU R31 14-9/16 33-9/16 6-3/16 THQMV 6-350 TGK12 installed
TSMR2015CSCU R30 14-9/16 40-1/2 6-3/16 THQMV 6-350 TGK12 (order separately)
TSMB2015CSCU R18 14-3/4 33 6-5/16 THQMV 1-300 TGK12 (order separately)
TSLB420CSCU R14 14 30-3/4 5-3/4 Field Installed2 6-350 TGL1 installed
TSLR420CSCU R31 14-9/16 33-9/16 6-3/16 Field Installed2 6-350 TGK12 (order separately)
TSMR420CSCU R31 14-9/16 33-9/16 6-3/16 THQMV 6-350 TGK12 installed
TSMR2020CSCU R30 14-9/16 40-1/2 6-3/16 THQMV 6-350 TGK12 (order separately)
TSMB2020CSCU R18 14-3/4 33 6-5/16 THQMV 1-300 TGK12 (order separately)
2THQL and THHQL only. 125 amp max. TQDL is obsolete.

Rev. 11/13 www.geindustrial.com BuyLog Catalog 1-21


Data subject to change
without notice
Load Centers and Circuit Breakers Section 1
Meter Socket LC
PowerMark Gold Meter Socket Load Centers 1PH
Single-Phase, Three-Wire, 120/240 Vac Ringless
With Bonded Neutrals Georgia Power
Florida Meter Group
Main Breaker
NEMA 3R
Georgia Power Ringless - Main Breaker
Main
Ampere 1 Pole, 2 Pole, 1 Pole, 2 Pole, Total 1-pole Enclosure Bypass UL Agency Product
Rating 1 Spaces 1 Spaces 1/2 Spaces 1/2 Spaces Spaces Type Front Type Type Incoming Certification Number
150 Outdoor Surface None OH/UG UL/GP TSMR015CSGP1,4
(NEMA 3R)
200 Outdoor Surface None OH/UG UL/GP TSMR020CSGP1,4
(NEMA 3R)
150 4 2 8 3 8 Outdoor Surface None OH/UG UL/GP TSMR415CSCUGP1,4
(NEMA 3R)
200 4 2 8 3 8 Outdoor Surface None OH/UG UL/GP TSMR420CSCUGP1,4
(NEMA 3R)

Application Data
Main Wire Size
Box Unit Width Unit Height Depth Factory Inst. (AWG/kcmil) Equipment
Product Number Number (in inches) (in inches) (in inches) Svcs Disc Cu-Al Ground Kit
TSMR015CSGP R32A 18-7/8 18-9/16 5 THQD 2-250
TSMR020CSGP R32A 18-7/8 18-9/16 5 THQD 2-250
TSMR415CSCUGP R40 14 32 4-1/2 THQMV 6-350 TGL2 included
TSMR420CSCUGP R40 14 32 4-1/2 THQMV 6-350 TGL2 included

Florida Meter Group MSLC Ringless - Main Breaker


Main
Ampere 1 Pole, 2 Pole, 1 Pole, 2 Pole, Total 1-pole Enclosure Bypass UL Agency Product
Rating 1 Spaces 1 Spaces 1/2 Spaces 1/2 Spaces Spaces Type Front Type Type Incoming Certification Number
150 4 2 8 3 8 Outdoor Surface None OH/UG UL/FMG TSMR415CSFLFMG
(NEMA 3R)
200 4 2 8 3 8 Outdoor Surface None OH/UG UL/FMG TSMR420CSFLFMG
(NEMA 3R)
150 8 4 16 6 16 Outdoor Surface None OH/UG UL/FMG TSMR815CSFLFMG4
(NEMA 3R)
200 8 4 16 6 16 Outdoor Surface None OH/UG UL/FMG TSMR820CSFLFMG4
(NEMA 3R)
200 20 4 40 18 40 Outdoor Surface None OH/UG UL/FMG TSMR2020CSCUFMG2
(NEMA 3R)

Application Data
Main Wire Size
Box Unit Width Unit Height Depth Factory Inst. (AWG/kcmil) Equipment
Product Number Number (in inches) (in inches) (in inches) Svcs Disc Cu-Al Ground Kit
TSMR415CSFLFMG R36A 14 28-1/2 4-1/2 THQMV 6-350 TGL2 included
TSMR420CSFLFMG R36A 14 28-1/2 4-1/2 THQMV 6-350 TGL2 included
TSMR815CSFLFMG R37A 14 31-3/4 4-1/2 THQMV 6-350 TGK24 included
TSMR820CSFLFMG R37A 14 31-3/4 4-1/2 THQMV 6-350 TGK24 included
TSMR2020CSCUFMG R403 14 34-1/2 4-1/2 THQMV 6-350 TGK24 included
1Use FMG unit if Ringless standard UL design is required by your local utility.
2No feed through lugs.
3Knock outs are the same as R36A.
4Feed-thru lugs provided.

1-22 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Load Centers and Circuit Breakers Section 1
Meter Socket LC
PowerMark Gold Meter Socket Load Centers 1PH
Single-Phase, Three-Wire, 120/240 Vac Class 320
With Bonded Neutrals NEMA 3R

Class 320
Main 1 Pole, 2 Pole, 1 Pole, 2 Pole, Total
Ampere 1 1 1/2 1/2 1-pole Enclosure Bypass UL Agency Product
Rating Spaces Spaces Spaces Spaces Spaces Type Front Type Type Incoming Certification Number
320 24 12 32 14 40 Outdoor Surf/Semi None UG UL TM2432RMS1,2,3
(NEMA 3R)
400 0 0 0 0 0 Outdoor Surf/Semi Lever Bypass UG UL TSDR040UFCU4
(NEMA 3R)
300 8 4 16 6 16 Outdoor Surface Lever Bypass UG UL TSDR830USCU4
(NEMA 3R) FMG
400 8 4 16 6 16 Outdoor Surface Lever Bypass UG UL TSDR840UFCU4
(NEMA 3R) FMG
400 24 12 32 14 40 Outdoor Surf/Semi Lever Bypass UG UL TM2440RMRS1,2,3
(NEMA 3R)
400 24 12 32 14 40 Outdoor Surf/Semi None UG UL TM2440RMS1,2,3
(NEMA 3R) EUSERC
400 24 12 32 14 40 Outdoor Surf/Semi Lever Bypass UG UL TMH2440RMRS1,2,3,4
(NEMA 3R) Xcel
400 24 12 32 14 40 Outdoor Surf/Semi None UG UL TMH2440RMS1,2,3,4
(NEMA 3R)
320 0 0 0 0 0 Outdoor Surf/Semi Lever Bypass UG UL TSD032UFCU4
(NEMA 3R)
320 24 12 32 14 42 Outdoor Surf/Semi Link Bypass UG UL TSDA2432UC424
(NEMA 3R) EUSERC
400 24 12 32 14 42 Outdoor Surf/Semi Link Bypass UG UL TSDA2440UC424
(NEMA 3R) EUSERC
1200A main breaker factory installed. Space provided for field mounted TQD-WL sub feed.
2For semi-flush applications, order surface enclosure load center and field installed kit, Product number SF400.
3Stud provisions only provided.
422 kAIC.

Application Data
Main Wire Size
Product Box Unit Width Unit Height Depth Factory Inst. Field Inst. (AWG/kcmil) Equipment
Number Ringless Number (in inches) (in inches) (in inches) Main Breaker Main Breaker Cu-Al Ground Kit
TM2432RMS No R24 30-1/4 40 6 TQD THQL (1) 800 or (2) 400 compression type; (2) TGL2
(1) 1000 or (2) compression type; (order separately)
(1) 1000 or (2) 350 pressure type
TM2440RMS No R24 30-1/4 40 6 TQD TQD (1) 800 or (2) 400 compression type; (2) TGL2
(1) 1000 or (2) 350 pressure type (order separately)
TMH2440RMS No R24 30-1/4 40 6 THQD THQD (1) 800 or (2) 400 compression type; (2) TGL2
(1) 1000 or (2) 350 pressure type (order separately)
TSDA2432UC42 No R24 30-1/4 40 6 THQD THQL/THHQL (1) 800 or (2) 400 compression type (2) TGL2
(order separately)
TSDA2440UC42 No R24 30-1/4 40 6 THQD TQD/THQD (1) 800 or (2) 400 compression type (2) TGL2
(order separately)
TSD032UFCU No R33 30-1/4 33 6-3/32 THQD THQL/THHQL (1) 800 or (2) 400 compression type (2) TGL2
(order separately)
TM2440RMRS Yes R24 30-1/4 40 6 TQD TQD (1) 800 or (2) 400 compression type; (2) TGL2
(1) 1000 or (2) 350 pressure type (order separately)
TMH2440RMRS Yes R24 30-1/4 40 6 THQD THQD (1) 800 or (2) 400 compression type; (2) TGL2
(1) 1000 or (2) 350 pressure type (order separately)
TSDR040UFCU Yes R33 30-1/4 33 6-3/32 THQD TQD/THQD (1) 800 or (2) 400 compression type (2) TGL2
(order separately)
TSDR840UFCU Yes R33 30-1/4 33 6-3/32 THQD TQD/THQD (1) 800 or (2) 400 compression type (2) TGL2
(order separately)

Rev. 11/13 www.geindustrial.com BuyLog Catalog 1-23


Data subject to change
without notice
Page Updated 01 / 2017

Load Centers and Circuit Breakers Section 1


PowerMark Gold and Plus Load Centers
Circuit Breakers
Field Installed Accessories

PowerMark Gold Main Circuit Breaker Kit


For use with 125A PowerMark Gold load Centers; 22kAIC RMS symmetrical.
Product
Description Number
Main Circuit Breaker Kit - Order appropriate THQL TQMH0001
10kAIC or THHQL 22kAIC breakers separately. Includes service barriers for use with THQL or THHQL main.
1Please review the footnotes listed with the individual Load Center product numbers for proper parts needed to
convert to a main circuit breaker. This main breaker base is only applicable for 16 circuit and larger 125 amp load
centers, 12 circuit load centers with A C24 suffix, and the TLM812RCU2.
TQMH000

PowerMark Plus Equipment Ground Kits


Product
Description Standard Package Quantity Number
(4) 14-8Cu/12-8AL, 20 TGL1 TGL2
(3) 14-4Cu/6-4AL
(8) 14-8Cu/12-8AL, 20 TGL21
(6) 14-4Cu/6-4AL
(7) 14-8Cu/12-8AL, (3) 14-4Cu/6-4AL, 20 TGL81
(2) 14-4Cu/12-4AL, (1) 14-2Cu/AL
(1) 6-2/0Cu/Al Number of Terminals, 20 TGL202
Equipment Ground Kits
(3) 10-1/0 Cu/Al Number of Terminals 1 TNG33
for 400 and 600 Amp
(6) 10-1/0 Cu/Al Number of Terminals 1 TNG64
for 400 and 600 Amp
1TGL2, TGL4 and TGL8 mount interchangeably TGL20 combined with TGL1
2Add-on Equipment Ground Lug (for use on any TGL Kit)
3Suitable for use with up to six TPLUG108 lugs or six crimp lugs per pole

PowerMark Gold Equipment Ground and Isolated Ground Bar Kits4,5


Product
Description Standard Package Quantity Number
4-hole Ground 1 TGK4
12-hole Ground 1 TGK12
24-hole Ground 1 TGK24 TGK12
32-hole Ground 1 TGK32
42-hole Ground 1 TGK42
46-12 circuit indoor load centers use PowerMark Plus style neutrals and grounds
5Add TGKIS for isolated ground and mount to ground kit.

TGK12 with TGKIS

1-24 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Load Centers and Circuit Breakers Section 1
PowerMark Gold and Plus Load Centers
Circuit Breakers
Field Installed Accessories

PowerMark Plus Neutral Kits


Wire Standard Product
Description Range Package Quantity Number
400 & 600 Amp PowerMark Plus Neutral Kit (5) 14-1/0 1 TNLK11
400 & 600 Amp PowerMark Plus Neutral Kit (3) 1-300 1 TNLK21
Add-on neutral lug for 100-200 Amp PowerMark 6-2/0 1 286A8894G1
Plus load centers
Add-on neutral lug for 100-200 Amp PowerMark 1-300 Cu or 1 192A7663G13
Plus load centers 2/0-300 Al 192A7663G13 286A8894G1
1Suitable for use with up to six TPLUG108 lugs or six crimp lugs per pole

PowerMark Gold Neutral Kits


Wire Standard Product
Description Range Package Quantity Number
PowerMark Gold Neutral Kit - 6-2/0 1 TNLK20
Mounted on top of neutral only
PowerMark Gold Neutral Kit - 6-250 1 TNLK250
Mounted on top of neutral only
TNLK250

PowerMark Gold Neutral/Ground Lug Kits


Mounted on any neutral or ground position by removing the termination screw
Wire Standard Product
Description Range Package Quantity Number
Neutral/Ground Lug Kit 6-2/0 1 TLK20
Neutral/Ground Lug Kit 6-250 1 TLK250
Neutral/Ground Lug Kit 6-300 1 TLK300
TLK20 TLK250

Isolated Ground Bus Bars Equipment Ground Kit


Standard Product
Description Package Quantity Number
Isolated Ground Bar Kit (order with 1 TGKIS
TGK Equipment Ground Kits)
Isolated Ground Bar Feet (Order with TGK8) 1 TGKIS2

TGK12 with TGKIS


Subfeed Lug Kits
Standard Product
Description Package Quantity Number
125A 2 Pole Plug-in 1 THLK2125
150A 2 Pole Plug-in - For use with PowerMark Gold only 1 THLK2150
200A 2 Pole Plug-in - For use with PowerMark Gold only 1 THLK2200
125A 3 Pole Plug-in 1 THLK3125
225A 3 Pole Plug-in - For use with 3 phase only 1 THLK3225

Sub-feed and Feed-thru Lugs


UL Listed
For use in load centers to economically supply power to a subpanel.
Product
Poles Ampere Rating Number
THLK2125
2 125 THLK2125
3 125 THLK3125
2 150 THLK21501
2 200 THLK22001
3 225 THLK32252
1For use with PowerMark Gold load centers only
2For use with three-phase load centers only. Includes mounting base.

Rev. 11/13 www.geindustrial.com BuyLog Catalog 1-25


Data subject to change
without notice
Load Centers and Circuit Breakers Section 1
PowerMark Gold and Plus Load Centers
Circuit Breakers
Field Installed Accessories

PowerMark Plus Main Lug Kits


Product
Description Wire Range (Cu/Al) Number
150 Amp PowerMark Plus Replacement Main Lug kit 2-3/0 THLK150
200 Amp PowerMark Plus Replacement Main Lug kit 1-250 THLK200

THLK200

PowerMark Gold Main Lug Kits


Product
Description Wire Range (Cu/Al) Number
125 Amp PowerMark Gold Replacement Main Lug kit 6-2/0 TMLK125
200 Amp PowerMark Gold Replacement Main Lug kit 6-250 TMLK200
225 Amp PowerMark Gold Replacement Main Lug kit 6-300 TMLK225

For replacement of main lugs on 125 amp load centers; TLM load centers include main lugs.
PowerMark Gold main lug kits - TMLK200

Door Lock
Standard Product
Description Package Quantity Number
For indoor load centers larger than 12 circuits (Does not fit TPL412) 10 TDL106

TDL106

Circuit Directory
Standard Product
Description Package Quantity Number
Card and holder with pressure-sensitive backing. 1 TD42
Mounts inside the door.

TD42

Touch-up Paint
Standard Product
Description Package Quantity Number
12 3/4 oz. spray can of light gray enamel 1 TSP61

TSP61

1-26 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Load Centers and Circuit Breakers Section 1
PowerMark Gold and Plus Load Centers
Circuit Breakers
Field Installed Accessories

Front Filler Plates


Standard Product
Description Package Quantity Number
1/2 Front Filler Plate 100 TFH TFH
1 Front Filler Plate 50 TQLFP1

Covers 1/2 rectangular breaker knockouts


Covers 1 rectangular breaker knockouts

Universal Raintight Hubs


Standard Product
Description Base Size (in.) Package Quantity Number
3/4 Diameter 3 10 TC75
1 Diameter 3 10 TC100
1-1/4 Diameter 3 10 TC125
1-1/2 Diameter 3 10 TC150
2 Diameter 3 10 TC200
2-1/2 Diameter 3 10 TC250
3 Diameter 3 5 TC300
Closing Cap 3 10 TCCP TC150
2 Diameter 4 TCU271
2-1/2 Diameter 4 TCU281
3 Diameter 4 TCU301
3-1/2 Diameter 4 TCU351
4 Diameter 4 TCU401
4 Cover Plate 4 TCUP1
1For 40 and 42 circuit units in R8 boxes only.

Door Handle
Standard Product
Description Package Quantity Number
Replacement Door Handle Universal 1 TRL22

TRL22

PowerMark Gold Cross Arm


Standard Product
Description Package Quantity Number
Replacement cross arm for
PowerMark Gold load centers 1 LCCROSSARM

LCCROSSARM

Rev. 11/13 www.geindustrial.com BuyLog Catalog 1-27


Data subject to change
without notice
Page Updated 01 / 2017

Load Centers and Circuit Breakers Section 1


PowerMark Gold and Plus Load Centers
Circuit Breakers
Field Installed Accessories

PowerMark Gold Main Breaker Retainers


Includes service barriers for use with THQL main
Main Breaker Retainer Kits are UL listed (Panelboards No. 67)
Product
Description Breaker Type Number THQLRK THQLRK2
Travel Trailer Main Breaker Retainer Kit THQP THQPSBK
for THQP Breakers
For use on PowerMark Plus load centers with THQL THQLRK
THQL Breakers 225A max
For use with 12 - 42 circuit PowerMark Gold THQL THQLRK1
load centers with THQL Breakers
For use with 6 - 8 circuit PowerMark Gold THQL THQLRK2
load centers with THQL Breakers THQLRK1 THQLRK3
For use with TM/TLM1212CCU Mod 2 current model THQL THQLRK3
For use with 6 - 42 circuit PowerMark Gold THQL THQLRK4
load centers with THQL Breakers. Similar to
THQLRK1 but it does not take up a breaker space.

For main lug load centers utilizing a back fed branch breaker as a main

THQLRK4
Handle Locks - Padlocking
Product
Description Breaker Type Number
THQP Padlocking Handle Lock THQP TQPPL
THQL Padlocking Handle Lock THQL THP100
TQD Padlocking Handle Lock TQD TQDPLD1

Snap on handle lock


Padlock not included
THL103

Handle Locks - Non Padlocking


Product
Description Breaker Type Number
THQP Non Padlocking Handle Lock THQP TQPL
THQL Non Padlocking Handle Lock THQL THL103

Snap on handle lock

THT1
Handle Ties
Product
Description Breaker Type Number
Handle Ties for THQP Breakers - Solid Snap-on THQP THT11
Trip Indicating
Handle Ties for THQP Breakers - For 2 THQPs THQP THT21
separated by 2 side-by-side THQPs
TQB
Snap-on Handle Tie - Trip Indicating TQC TQHT11 THT104
TQL
TQB
Snap-on Handle Tie - Solid TQC THT1041
TQL
TQB
Multiwire Branch Breaker TQ3HTK2
TQC
Handle Tie Kits TQ4HTK3
TQL

All multi-pole breakers have internal common trip


Handle ties provide manual on-off capability only between one-pole devices
1For two single-pole breakers THT2
2For three single-pole breakers - kit includes (10) pcs.
3For four single-pole breakers - kit includes (10) pcs.

TQHT1

1-28 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Page Updated 01 / 2017

Load Centers and Circuit Breakers Section 1


PowerMark Gold and Plus Load Centers
Circuit Breakers
Field Installed Accessories

Service Barrier Kits for PowerMark Load Centers


Field installed service barrier kits.
These kits are normally supplied with service entrance load centers
and main circuit breaker kits
Service Barriers UL listed (Panelboards No. 489) and compliant
to UL 67 standards THQLSB THQMVSBF
Product
Description Number
THQL Service Barrier THQLSB
THQMV Service Barrier Flapper THQMVSBF
2 or 4 Circuits Service Barrier. For use with: TL240RCU, TL240RCUP, TLSB
TL270RCU, TL270RCUP, TL240SCU, TL240SCUP, TL270SCU, TL270SCUP
TQD Service Barrier TQDSB
TQD Lug Service Barrier 100-125A Reducer TQDSBR
TQD/SF Service Barrier Plug TQDSFSBP

TLSB TQDSB
Service Barrier Kits for PowerMark Meter Socket Load Centers
Field installed service barrier kits.
These kits are normally supplied with service entrance load centers
and main circuit breaker kits
Service Barriers UL listed (Panelboards No. 489) and compliant TQDSBR TQDSFSBP
to UL 67 standards
Product
Description Number
MSLC Bus Service Barrier TSMBSB
MSLC Lug Service Barrier TSMLSB
MSLC Service Barrier 2P Module TSMLSB2P
MSLC Lug Service Barrier Bus Filler TSMLSBF
MSLC Lug Service Barrier Shutter TSMLSBS
MSLC Lug Service Barrier Reverse Feed TSMLSBR

TSMBSB TSMLSB

Load Center Hardware Kits Hardware


Standard Product
Description Package Quantity Number
PowerMark Plus hardware kit: TQD THQD Main or 1 LCHDKIT
THLK main lug kit in a TLM load center, installation
instructions and front mounting screws
Powermark Gold Bond Screw Kit Screw 100 - 200A 1 TBS
Powermark Gold Bond Screw Kit 225A 1 TBS22
Powermark Gold Hardware kit 1 THDWRKIT
TSMLSB2P TSMLSBF
containing 20 front mounting screws
Powermark Gold Hardware kit 1 THDWRKIT2
containing 10 interior mounting screws

Generator Interlock Kit


Standard Product
Description Package Quantity Number
Load Center Generator Interlock Kit 1 THQLLX1
MSLC Generator Interlock Kit 1 THQLLX4
TSMLSBS TSMLSBR
MSLC Generator Interlock Kit 1 THQLLX8CU
MSLC Generator Interlock Kit 1 THQLLX8DR
MSLC Generator Interlock Kit 1 THQLLX8FL

Rev. 11/13 www.geindustrial.com BuyLog Catalog 1-29


Data subject to change
without notice
Load Centers and Circuit Breakers Section 1
PowerMark Gold and Plus Load Centers
Circuit Breakers
Field Installed Accessories

PowerMark Gold Auxiliary Gutter Enclosures


Product
Description Number
24 Auxiliary Gutter Enclosure TMAGB24
28 Auxiliary Gutter Enclosure TMAGB28
28 Auxiliary Gutter Enclosure Flush TMAGB28F
33 Auxiliary Gutter Enclosure TMAGB33
39 Auxiliary Gutter Enclosure TMAGB39
43 Auxiliary Gutter Enclosure TMAGB43
43 Deep Auxiliary Gutter Enclosure TMAGB43D

PowerMark Gold Gutter Tap Kits


Product
Description Number
250 kcmil Lugs Gutter Tap Kit - one kit per phase required TMGT250
500 kcmil Lugs Gutter Tap Kit - one kit per phase required TMGT500
750 kcmil Lugs Gutter Tap Kit - one kit per phase required - TMGT750
Not for use with riser panels

Meter Socket Load Center Flange Kits


Product
Description Number
Semi-Flush Kit 400A for MSLC SF400
Semi-Flush Kit 400A for MSLC Adjustable SF400A
Semi-Flush Kit 200A for MSLC Adjustable SF200A

Surge Protectors
Product
Description Number
SurgePro AC 27KA Panel-Mount Surge Protector THQLSURGE

1-30 BuyLog Catalog www.geindustrial.com Rev.11/13


Data subject to change
without notice
Load Centers and Circuit Breakers Section 1
PowerMark Gold and Plus Load Centers
Circuit Breakers
Wiring Diagrams A A

G G G E

Breaker Fill
Breaker Symbol 1 THQL 1/2 THQP
1
TL240SCU, RCU
1 2
TL270SCU, RCU TL510RT

Wire Range (AWG/kcmil)


Terminal Symbol Cu Al T
o 14-8 12-8
14-4 12-4
MAIN LUGS
A 6-2 6-2 MAIN LUGS

C C
B 14-1/0 12-1/0
C
C 6-2/0 6-2/0
D 1-300 2/0-300
E 1-300 1-300
F 6-1 6-1
TPL412C, TL412C, TPL412R, TL412R1, TPL412CT, TL412CT
G 6-3 6-3 TL412R2, TL412R250GF, TL412R260GF TPL412RT, TL412RT1

C MAIN
E
F F F F BREAKER

F MAIN MAIN
F F BREAKER BREAKER

SUBFEED
LUGS

TM860FCUGEN, TLM830FCUGEN,
TLM612FCU, SCU TLM812FCU, SCU, TM815RCUFL TM860SCUGEN, TLM830SCUGEN,
FCUD, SCUD, RCU FCUD, SCUD, RCU TM820RCUFL TM860RCUGEN, TLM830RCUGEN

C C C C C C C C C C E
MAIN
MAIN MAIN

TM1210CCU, TM1212CCU, TLM1212CCU TM1210RCU, TM1212RCU, TLM1212RCU TLM2012CCURP

MAIN C C MAIN E
C
F F

C MAIN C

TLM1612CCU, TM1612CCU, TM1612RCU TM1615CCU, TM1615RCU, TM1620CCU, TLM812RCU2 TM2420R42B


TLM1620CCU, TLM1620RCU

Rev. 11/13 www.geindustrial.com BuyLog Catalog 1-31


Data subject to change
without notice
Load Centers and Circuit Breakers Section 1
PowerMark Gold and Plus Load Centers
Circuit Breakers
Wiring Diagrams C MAIN E
MAIN C

Breaker Fill
Breaker Symbol 1 THQL 1/2 THQP
1
1 2 TM2020CCU, TM2020RCU
TM2010CCU, TM2010RCU TLM2020CCU, TLM2020RCU

Wire Range (AWG/kcmil)


MAIN C
C MAIN E
Terminal Symbol Cu Al
o 14-8 12-8
14-4 12-4
A 6-2 6-2
B 14-1/0 12-1/0
C 6-2/0 6-2/0
D 1-300 2/0-300
E 1-300 1-300
F 6-1 6-1
TM2410CCU, TM2412CCU
G 6-3 6-3 TM2415RCU, TLM2415RCU
TM2412RCU, TLM2412CCU, TLM2412RCU

C C E

MAIN C E
C E MAIN
MAIN
MAIN

TM3220CCU, TM3220RCU,
TLM2420C42, TM2415C42 TM3210CCU TM3215CCU, TM3215RCU
TLM3220CCU, TLM3220RCU

MAIN MAIN
C E C E

MAIN
MAIN
C

TM4020CCU, TM4020RCU TM4222RCU, TLM4222CCU


TLM4020CCU, TLM4020RCU TLM4222RCU, TM4222CCU TM12410 TL12412

C E

MAIN

TM3215C42, TLM3220C42, TM3220C42

1-32 BuyLog Catalog www.geindustrial.com Rev.11/13


Data subject to change
without notice
Load Centers and Circuit Breakers Section 1
PowerMark Gold and Plus Load Centers
Circuit Breakers
Wiring Diagrams

Breaker Fill
MAIN
Breaker Symbol 1 THQL 1/2 THQP C C D
MAIN
1 C C D

1 2

Wire Range (AWG/kcmil)


Terminal Symbol Cu Al
o 14-8 12-8
14-4 12-4
A 6-2 6-2
B 14-1/0 12-1/0
C 6-2/0 6-2/0
D 1-300 2/0-300
E 1-300 1-300
TL18415, TL18420 TL24415, TM24415
F 6-1 6-1
G 6-3 6-3

MAIN
MAIN MAIN
C C D C C C D

MAIN

D D D C C C C C C C

MAIN

TL24440, TM24420 TM18410 TM30412 TM30415, TL30420, TM30240, TL30422

Rev. 11/13 www.geindustrial.com BuyLog Catalog 1-33


Data subject to change
without notice
Load Centers and Circuit Breakers Section 1
PowerMark Gold and Plus Load Centers
Circuit Breakers
Wiring Diagrams

Breaker Fill
Breaker Symbol 1 THQL 1/2 THQP
1
1 2

Wire Range (AWG/kcmil)


Terminal Symbol Cu Al
o 14-8 12-8
14-4 12-4
A 6-2 6-2
B 14-1/0 12-1/0
C 6-2/0 6-2/0
D 1-300 2/0-300
E 1-300 1-300
F 6-1 6-1
G 6-3 6-3

MAIN MAIN
C C D C C C D

TL42420, TM42415C, TM42420 TL42422

1-34 BuyLog Catalog www.geindustrial.com Rev.11/13


Data subject to change
without notice
Load Centers and Circuit Breakers Section 1
PowerMark Gold and Plus Load Centers
Circuit Breakers Wire Range (AWG/kcmil)
Wiring Diagrams Terminal Symbol Cu Al
o 14-8 12-8
14-4 12-4
A 6-2 6-2
B 14-1/0 12-1/0
C 6-2/0 6-2/0
Breaker Fill D 1-300 2/0-300
Breaker Symbol 1 THQL 1/2 THQP E 1-300 1-300
1 F 6-1 6-1
1 2 G 6-3 6-3

A C BB C
WHM

MAIN

WHM
A
A
A

TM10RMC, TM12RMC, TM15RMC, TM20RMC,


TSMR015CSGP, TSMR020CSGP
TSL210CSCU, TSL210CFCU

C
WHM WHM
WHM

MAIN
A
A Load
Load D D C
B
A
A A
A A E
A

TSM415CSCU, TSM420CSCU, TSMF415CSFL,


TSMF420CSFL, TSMR415CSCUGP, TSMR420CSCUGP,
TSL412CSCU TSL420CSCU, TSL420CFCU TSMR415CSFLFMG, TSMR420CSFLFMG

SPACE PROVIDED
WHM FOR 110A PARALLEL WHM
MAIN BREAKER MAIN
BREAKER
WHM
MAIN
MAIN BREAKER
BREAKER

C C C C
C C
C C

TSF420CSCU TSM1212CSCU, TSM1212CFCU TSM815CSCU, TSM820CSCU

Rev. 11/13 www.geindustrial.com BuyLog Catalog 1-35


Data subject to change
without notice
Load Centers and Circuit Breakers Section 1
PowerMark Gold and Plus Load Centers
Circuit Breakers Wire Range (AWG/kcmil)
Wiring Diagrams Terminal Symbol Cu Al
o 14-8 12-8
14-4 12-4
A 6-2 6-2
B 14-1/0 12-1/0
C 6-2/0 6-2/0
Breaker Fill D 1-300 2/0-300
Breaker Symbol 1 THQL 1/2 THQP E 1-300 1-300
1 F 6-1 6-1
1 2 G 6-3 6-3

WHM
MAIN
BREAKER

WHM
MAIN
BREAKER

C
C C
C

TSM1610CSCU, TSM1610CFCU, TSM1612CFCU, TSM1612CSCU TSM2020CSCU, TSM2020CFCU

D
C E

C WHM MAIN
BREAKER
WHM

C E

MAIN

D DC

C MAIN C E

A MAIN
BREAKER
Sub feed lugs WHM
A
WHM
B
A PH B PH
NEUTRAL
N
TSM815CSFL, TSM820CSFL, TSMF815CSFL, TSM3220USCU, TSM3220UFCU, TSM3222USCU,
TSM2420UF42 TSMF820CSFL, TSMR815CSFLFMG, TSM3220UWCU
TSM3222UFCU
TSMR820CSFLFMG

WHM MAIN
BREAKER WHM
C E
WHM

MAIN
BREAKER
WHM

MAIN
BREAKER

TSMR2020CSCU, TSMR2015CSCU, TSLR420CSCU, TSLR412CSCU,


TSM4020UWCU TSMR1212CSCU, TSMB1212CSCU
TSMB2020CSCU, TSMB2015CSCU TSLB412CSCU, TSLB420CSCU

1-36 BuyLog Catalog www.geindustrial.com Rev.11/13


Data subject to change
without notice
Load Centers and Circuit Breakers Section 1
PowerMark Gold and Plus Load Centers
Circuit Breakers Wire Range (AWG/kcmil)
Wiring Diagrams Terminal Symbol Cu Al
o 14-8 12-8
14-4 12-4
A 6-2 6-2
B 14-1/0 12-1/0
C 6-2/0 6-2/0
Breaker Fill D 1-300 2/0-300
Breaker Symbol 1 THQL 1/2 THQP E 1-300 1-300
1 F 6-1 6-1
1 2 G 6-3 6-3

C WHM Space for


Field-installed C E
Ground
termination
WHM TQD Breaker

200A
MAIN
Main
Breaker
CC C D
D D C
L1 N L2

MAIN
BREAKER
E WHM

A PH B PH

NEUTRAL
TM2440RMRS, TM2440RMS,
TSMR2020CSCUFMG TSM2022USCU, TSM2022UFCU
TMH2440RMS, TMH2440RMRS

Space for
Field-installed
Breaker

WHM Line
C

C
C
MAIN
C E WHM
L1 N L2

MAIN C E

C
Neutral

TSDA2432UC42, TSDA2440UC42 TSM2015URCU

Space for Field Installed


Second Main Breaker

Space for Field Installed


Space for Field Installed
Second Main Breaker
Second Main Breaker
WHM

WHM WHM
MAIN

C E
MAIN MAIN

TSD032UFCU TSDR040UFCU TSDR840UFCU

T
Rev. 11/13 www.geindustrial.com BuyLog Catalog 1-37
Data subject to change
without notice
Load Centers and Circuit Breakers Section 1
PowerMark Gold and Plus Load Centers
Circuit Breakers
Indoor Enclosures

Knockouts
Symbol A B C D E F G H J K L M N P Q R S T U V W X Y Z
5/16
3/8 3/8 3/8
1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2
3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4
Conduit 1 1 1 1 1 1 1 1 1 1 1 1 1
Size 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4
in 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2
inches 2 2 2 2 2 2 2 2 2 2
2 1/2 2 1/2 2 1/2 2 1/2 2 1/2 2 1/2 2 1/2 2 1/2
3 3 3
3 1/2 3 1/2 3 1/2
4

Dimensions (in inches)


Box No. Width Height Depth
X
1A 5 11/16 10 1/4 3 3/8
J
2 7 1/2 9 7/32 3 5/16
A D
2A 7 1/4 9 3 H A D
3A 11 9/16 11 3/8 3 3/8
H A
4 14 19 3 3/4
A D
4A 14 19 3 3/4 A G
6 14 23 3 3/4 D
7 14 24 11/16 3 3/4 X
W X
8 14 26 7/16 3 3/4
9 14 28 7/16 3 3/4
A G A W
9A 14 28 7/16 3 3/4 A
11 14 33 3/16 3 3/4 H H
12 14 35 7/16 3 3/4 A W
D B
13 14 39 3/16 3 3/4 A J
14 14 43 7/16 3 3/4 D X
15 14 43 7/16 4 5/8
16 16 45 1/8 5 13/16 Box 1A Box 2
17 20 59 7/8 6 3/32
18 14 16 3 3/8

C G
HD Y A H Z
K
Q Q
A A
H Q M A
H D B
K H A
G K D D
D
G D A D F A C
A
A Y Y
D D A M H
K H Y G Z
B D
B
Box 2A Box 3A Box 4, 6, 7, 8, 9, 11, 12, 13, 14 Box 4A, 9A

B T J GUB V GJ D K B D
C B C SB C
B B B D B B B B D

H P K D
K

B B B B D
K
S B S A A C
P B J K
B A
K AA
AA
B R
C
H A D
D
A D

CN B

D
D
B

A C A A B
D B

B P A B B D
D B B
B C N C B D B

A
D

B
D B

D D

A B B
S C
D

P
J
S K K A BP A B
A
P B C
C K C C
T B B J G J B
Box 15 Box 16 Box 17 Box 18

1-38 BuyLog Catalog www.geindustrial.com Rev.11/13


Data subject to change
without notice
Load Centers and Circuit Breakers Section 1
PowerMark Gold and Plus Load Centers
Circuit Breakers
Outdoor Enclosures

Knockouts

Symbol A B C D E F G H I J K L M N P Q R S T U V W X Y Z AA BB CC DD
9/32
3/8 3/8
1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2
9/16
3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4
Conduit 1 1 1 1 1 1 1 1 1 1 1 1 1 1
Size 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4
in 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2
Inches 2 2 2 2 2 2 2 2 2 2 2 2 2
2 1/2 2 1/2 2 1/2 2 1/2 2 1/2 2 1/2 2 1/2 2 1/2 2 1/2
3 3 3
3 1/2 3 1/2 3 1/2 3 1/2
4 4

Dimensions (in inches)

Box No. Width Height Depth


R1 7 1/2 9 7/32 3 5/16
X
R1A 7 1/4 10 3 3/4
R1B 7 3/8 13 3 3/4
R2A 11 1/4 11 1/8 3 1/4 D HUB
R3A 13 21 1/2 5
A
R3 12 1/2 21 3/16 4 5/8
R4A 14 11/16 30 3/16 5 1/4
R4 14 33 3/16 4 5/8 D
R5A 13 29 5 A
W X X
R5 12 1/2 28 11/16 4 5/8
R6A 13 33 5 W
R6 14 35 7/16 4 5/8 D
A
R7A 14 11/16 34 3/16 5 1/4 D D
B W
R7 14 39 3/16 4 5/8 G K
R8A 14 21/32 43 1/4 6 13/32
D X B
R8 14 43 11/16 5 3/4
R9 16 45 15/16 5 27/32
R10 20 48 15/16 6 7/8
Box R1 Box R1A Box R2A
R11 20 59 15/16 6 7/8
R41 7 1/2 13 1/4 4

Q R AK D
D
A

Q U U
Q R

D H J
Q D B

Box R3A, R5A, R6A Box R3, R4, R5, R6, R7 Box R8 Box R4A, R7A

Mounting provided
for universal hubs
R L
C L
J C B C
C

B R K
P R K K
J B
P
B B BC C K
B C C K
T J G V U B

R8A Box R9 Box R10, R11 Box R41

Rev. 11/13 www.geindustrial.com BuyLog Catalog 1-39


Data subject to change
without notice
Load Centers and Circuit Breakers Section 1
PowerMark Gold and Plus Load Centers
Circuit Breakers
Meter Socket Load Centers

Knockouts
Symbol A B C D E F G H J K L M N P Q R S T U V W X Y Z AA BB CC DD EE FF

5/32
3/8 3/8 3/8
1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2
3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4
Conduit 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
Size 1 1/4 1 1/4 1 1/4 1/1/4 1/1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4
in 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2
inches 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2
2 1/2 2 1/2 2 1/2 2 1/2 2 1/2 2 1/2 2 1/2 2 1/2 2 1/2 2 1/2 2 1/2
3 3 3
3 1/2 3 1/2 3 1/2 3 1/2
4 4

Dimensions (in inches)


Box No. Width Height Depth
R12 14 23 1/2 4 7/8
R14 14 30 3/4 5 3/4
R15 16 3/4 33 6 3/16
R16 16 3/4 33 6 3/16
B A
R17 16 3/4 34 1/4 7 5/16 F Q A K
F
R18 14 3/4 33 6 5/16
Y W E
R19 16 3/4 28 1/2 7 5/16 B
R20 14 3/4 27 5/16 5 7/16 B
R21 14 9/16 43 5/8 7 3/16 B
R22 16 3/16 48 1/8 7 3/16 Semi-Flush Only
Semi-Flush Only
R23 30 1/4 40 6
R24 30 1/4 40 6
F EE
F
HUB HUB F
PUNCHING PUNCHING

A A
F
B
B C B B C EE
EE

Box R12 Box R14

G B B
CC C C CC
C C G B B B B B
CC CC
B B B C C B B B B
B B B B
C C C B B B B
BB
A B B
B A
B C
B C
B BB
B
B BB CC
C B
Box R16 B
B C C
B B B B G
B B K C A
C
B B B
CC C C G B B CC C
B Q BB C CC
B B B
C C BBBB A

B
Box R17, R18 Box R19, R20

S S
Z Z
Z

S S
D R R
B K K

G R K G R
B AA
D AA
C D
K
B D D

Box R21, R22 Box R23 Box R24

1-40 BuyLog Catalog www.geindustrial.com Rev.11/13


Data subject to change
without notice
Load Centers and Circuit Breakers Section 1
PowerMark Gold and Plus Load Centers
Circuit Breakers
Meter Socket Load Centers

Knockouts
Symbol A B C D E F G H J K L M N P Q R S T U V W X Y Z AA BB CC DD EE FF

5/32
3/8 3/8 3/8
1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2
3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4
Conduit 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
Size 1 1/4 1 1/4 1 1/4 1/1/4 1/1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4
in 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2
inches 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2
2 1/2 2 1/2 2 1/2 2 1/2 2 1/2 2 1/2 2 1/2 2 1/2 2 1/2 2 1/2 2 1/2
3 3 3
3 1/2 3 1/2 3 1/2 3 1/2
4 4

HUB HUB HUB HUB


PUNCHING PUNCHING
PUNCHING PUNCHING
Dimensions (in inches)
Box No. Width Height Depth
R25 14 26 4 1/2
R26 14 9/16 43 5/8 6 3/16
R27 14 9/16 48 1/8 6 3/16
R28 22 1/2 27 7/8 6 1/4
R29 22 1/2 34 7/8 6 1/4
R30 14 9/16 40 1/2 6 3/16
R31 14 9/16 33 9/16 6 3/16 Z Z Z
R32 16 17 5
R32A 18 7/8 18 9/16 5
B B B
R40 14 32 4 1/2 1/4" B B
C
B B B B
Z B B
S K
S S B

Box R25 Box R26, R27

B BB B R
BB A
B L
EE EE BB BB B

G G C
B C B B
B B B B B B B C
C BB C BB B
B C B

Box R28 Box R29 Box R30


HUB HUB
PUNCHING PUNCHING

R
A
B L

C G G
B FF FF

B C
P P
Box R31
A B B A B
HUB
FF FF B
Box R32 Box R32A

9/32 CC CC CC

EE E EE
GG

Box R40

Rev. 11/13 www.geindustrial.com BuyLog Catalog 1-41


Data subject to change
without notice
Load Centers and Circuit Breakers Section 1
PowerMark Gold and Plus Load Centers
Circuit Breakers
Meter Socket Load Centers

Knockouts
Symbol A B C D E F G H J K L M N P Q R S T U V W X Y Z AA BB CC DD EE FF GG

5/32
3/8 3/8 3/8
1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2
3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4
Conduit 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
Size 1 1/4 1 1/4 1 1/4 1/1/4 1/1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4
in 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2
inches 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2
2 1/2 2 1/2 2 1/2 2 1/2 2 1/2 2 1/2 2 1/2 2 1/2 2 1/2 2 1/2 2 1/2 2 1/2
3 3 3 3
3 1/2 3 1/2 3 1/2 3 1/2
4 4

Dimensions (in inches)


Box No. Width Height Depth
R33 30 1/4 33 6 3/32
R34 30 1/4 40 6 3/32
R35 30 1/4 47 6 3/32
R36 14 28 1/2 4 1/2
R37 14 31 3/4 4 1/2
R38 14 49 1/2 10
S S Z S
R39 14 31 11/16 4 5/8 S S Z S
3/32 3/32
R40 14 32 4 1/2 3/32
K K K
3/32 3/32

D R R D K K K
D G D R R
AA AA D G D
D D D D D D D D D D D D D D D D

Box R33 Box R34, R35

HUB HUB HUB HUB

9/32 CC CC CC 9/32 CC CC CC
D B D B D
B B
EE E G G EE E EE L L
D D D D D
GG GG W

Box R36A, R37A Box R36B, R37B Box R38

HUB

EE EE
C C C C
EE
C C
EE 9/32 CC CC CC
9/32

C C C C C
K
EE C C
C C EE E EE
C d C C
GG

Box R39 Box R40

1-42 BuyLog Catalog www.geindustrial.com Rev.11/13


Data subject to change
without notice
Section Updated 09 / 2016

Modular Metering Section 2

Mini Mod III Nomenclature.....................................................................2-2


Mini Mod IIIRing Type and Ringless ...............................................2-3
Mini Mod IIITenant Main Circuit Breakers ...................................2-4
Mini Mod IIIFactory Installed Accessories...................................2-5
Mini Mod IIIField Installed Accessories.........................................2-6
Meter Mod III Nomenclature .................................................................2-7
Meter Mod IIIHow to Order; Short Circuit Ratings ..................2-8
Meter Mod IIIModular Metering Series Ratings........................2-9
Meter Mod IIIMain Breaker Modules,
Single-Phase and Three-Phase.....................................................2-11
Factory Installed Accessories ........................................................2-13
Meter Mod IIIMain Fusible Modules,
Single-Phase and Three-Phase.....................................................2-14
Factory Installed Accessories ........................................................2-15
Meter Mod IIIMain Fusible with Pull
Box and Main Lug Modules
Single-Phase and Three-Phase.....................................................2-16
Factory Installed Accessories ........................................................2-17
Meter Mod IIIMain Pull Box
Modules and Accessories
Single-Phase and Three-Phase.....................................................2-18
Meter Mod IIIMeter Stack Modules,
Single-Phase Plus Accessories ......................................................2-19
Meter Mod IIIMeter Stack Modules,
Three-Phase Plus Accessories.......................................................2-23
Meter Mod IIIMeter Stack Modules,
Phase Balancing...................................................................................2-24
Meter Mod IIIApplications Where
Center-Feeding Main Module is Required................................2-25
Mini Mod IIIEnclosure Knockout Dimensions..........................2-26
Meter Mod IIIEnclosure Knockout Dimensions......................2-27

Rev. 11/13 www.geindustrial.com BuyLog Catalog 2-1


Data subject to change
without notice
Modular Metering Section 2
Mini Mod III Nomenclature
Product Number Systemsi

Product Number Guide for Mini Mod III


(Product number for illustrative purposes only)

T MM 6 6 20 R F
GE Identification Special
MEG Approved

Type
MM = Mini Mod Ring Type
Enclosures
MMR = Mini Mod Ringless
R = Type 3R rainproof

Horizontal Bus Rating


Socket Rating
2 = 200A
12 = 125A
4 = 400A
20 = 200A
6 = 600A

Socket Positions
1-6

2-2 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Modular Metering Section 2
Mini Mod III
Basic Devices
Ring-Type and Ringless

Product Features
UL Listed (Panelboards No. 67)
Indoor/Outdoor Construction
Ring-Type and Ringless Meter Sockets
Bondable Neutral, Strap Included
11-inch Mounting Z Rail Included
Swing Away Mounting Feet Factory Installed
Underground, incoming feed only

TMM4412R
Ring Type Socket1
Main Standard MEG
Ampere Main Wire Size Service Equipment Product Product
Socket Amps No. of Sockets Rating AWG/kcmil Cu/A Ground Ground Number Number3
125 A 2 200 (1) 6 -300 6-2/0 14-4 TMM2212R2 TMM2212RF2
125 A 3 400 (1) 6 -600 or (2) 2/0 -250 4-300 14-4 TMM4312R TMM4312RF
125 A 4 400 (1) 6 -600 or (2) 2/0 -250 4-300 14-4 TMM4412R TMM4412RF
125 A 5 600 (2) 250 - 500 4-300 14-4 TMM6512R TMM6512RF
125 A 6 600 (2) 250 - 500 4-300 14-4 TMM6612R TMM6612RF
200 A 2 400 (2) 250 - 500 4-300 14-4 TMM4220R Use TMM6320RF
200 A 3 600 (2) 250 - 500 4-300 14-4 TMM6320R TMM6320RF
200 A 4 600 (2) 250 - 500 4-300 14-4 TMM6420R TMM6420RF
Use Meter Mod III
200 A 5 600 (2) 250 - 500 4-300 14-4 TMM6520R
or Ringless
Use Meter Mod III
200 A 6 600 (2) 250 - 500 4-300 14-4 TMM6620R
or Ringless

Ringless Type Socket4


Horned
Main Standard Bypass MEG
Ampere Main Wire Size Service Equipment Product Product Product
Socket Amps No. of Sockets Rating AWG/kcmil Cu/Al Ground Ground Number Number5 Number3
125 A 2 200 (1) 6 -300 6-2/0 14-4 TMMR2212R2 TMMR2212RHB2 TMMR2212RF2
125 A 3 400 (1) 6 -600 or (2) 2/0 -250 4-300 14-4 TMMR4312R TMMR4312RHB TMMR4312RF
125 A 4 400 (1) 6 -600 or (2) 2/0 -250 4-300 14-4 TMMR4412R TMMR4412RHB TMMR4412RF
125 A 5 600 (2) 250 - 500 4-300 14-4 TMMR6512R TMMR6512RHB TMMR6512RF
125 A 6 600 (2) 250 - 500 4-300 14-4 TMMR6612R TMMR6612RHB TMMR6612RF
200 A 2 400 (2) 250 - 500 4-300 14-4 TMMR4220R TMMR4220RHB TMMR4220RF
200 A 3 600 (2) 250 - 500 4-300 14-4 TMMR6320R TMMR6320RHB TMMR6320RF
200 A 4 600 (2) 250 - 500 4-300 14-4 TMMR6420R TMMR6420RHB TMMR6420RF
200 A 5 600 (2) 250 - 500 4-300 14-4 TMMR6520R TMMR6520RHB TMMR6520RF
200 A 6 600 (2) 250 - 500 4-300 14-4 TMMR6620R TMMR6620RHB TMMR6620RF

Short Circuit Ratings UL Listed


1One snap-type, aluminum sealing ring(TSR5) per socket included
All Mini Mod IIIs are UL listed for the short circuit rating at 240 Vac 2May be fed from overhead. Use hub TC300.
maximum in rms symmetrical amperes of the tenant breaker 3Units with F suffix have an additional cotter pin that has been added to the meter

installed, selected from table below. socket assembly to keep meter socket from detaching from base. These are
The short circuit rating is limited to the lowest interrupting rating required in all MEG areas as of January 2016.
4Includes factory installed fifth jaw.
of any tenant breaker installed. 5Units with HB suffix have a factory installed horn bypass included.
Replacement breakers shall be of the same manufacturer and
type and shall have an interrupting rating equal to or greater than
the interrupting rating of any tenant breaker presently installed in
this device.
Tenant Main Breaker Frame UL Listed AIC Rating
TMQD 100,000
TMQL 42,000
THQD 22,000
THHQL 22,000
TQD 10,000
THQL 10,000

GE breakers rated 10,000 AIC or greater when installed on the load side of the
Mini Mod III are protected for the interrupting rating per the UL Listing marked
on the tenant breaker.

Rev. 11/13 www.geindustrial.com BuyLog Catalog 2-3


Data subject to change
without notice
Modular Metering Section 2
Mini Mod III
Tenant Main Circuit Breakers

Tenant Main Circuit Breakers For 125 Amp Sockets


10,000 AIC 22,000 AIC 42,000 AIC
Ampere Rating Product Number Product Number Product Number
60 THQL2160 THHQL2160 TMQL2160
70 THQL2170 THHQL2170 TMQL2170
80 THQL2180 THHQL2180 TMQL2180
90 THQL2190 THHQL2190 TMQL2190 THQL, THHQL
100 THQL21100 THHQL21100 TMQL21100
110 THQL21110 THHQL21110
125 THQL21125 THHQL21125 TMQL21125
1251 TMQL21125SF
1Sub-feed lug kit, no overcurrent protection.

Tenant Main Circuit Breakers For 200 Amp Sockets


10,000 AIC 22,000 AIC 100,000 AIC
Ampere Rating Product Number Product Number Product Number TMQL
60 TMQD22060
70 TMQD22070
80 TMQD22080
90 TMQD22090
100 TQD22100 THQD22100 TMQD22100
125 TQD22125 THQD22125 TMQD22125
150 TQD22150 THQD22150 TMQD22150
175 TQD22175 THQD22175 TMQD22175
200 TQD22200 THQD22200 TMQD22200

Tenant Main Lug Wire Sizes (AWG/kcmil) TQD, THQD


Type Ampere Rating Copper Aluminum
60 8-3 8-2
THQL, THHQL 70-100 6-1/0 4-1/0
110-125 2-2/0 2-2/0
TMQL 60-125 10-1/0 10-1/0
60-90 6-1/0 6-1/0
TMQD 100-150 6-4/0 6-4/0
175-225 1/0-300 1/0-300
TQD, THQD 100-200 1-300 1-300

TMQD

2-4 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Modular Metering Section 2
Mini Mod III
Accessories
Factory Installed

Mini Mod III Factory Installed Lug Kit


Phase Neutral
GE Lug Kit
Main Mini Mod Amp. Rating Wire Size Wire Size Product Number Lugs Per Kit
TMM2212R, TMM2212RF
125 #6-300 #6-300
TMMR2212R, TMMR2212RF, TMMR2212RHB
TMM4312R, TMM4312RF
TMMR4312R, TMMR4312RF, TMMR4312RHB
125 (1) 2/0-600 or (2) #6-250 (1) 2/0-600 or (2) #6-250 TMMLK1 1 lug/kit, 1 lug per phase, 2 hole lug
TMM4412R, TMM4412RF
TMMR4412R, TMMR4412RF, TMMR4412RHB
TMM6512R, TMM6512RF
TMMR6512R, TMMR6512RF, TMMR6512RHB
125
TMM6612R, TMM6612RF
TMMR6612R, TMMR6612RF, TMMR6612RHB
TMM4220R
TMMR4220R, TMMR4220RF, TMMR4220RHB
TMM6320R, TMM6320RF
200 (2) 250-500 (2) 250-500 TMPAL30 1 lug per kit, 1 lug per phase
TMMR6320R, TMMR6320RF, TMMR6320RHB
TMM6420R, TMM6420RF
TMMR6420R, TMMR6420RF, TMMR6420RHB
TMM6520R
TMMR6520R, TMMR6520RF, TMMR6520RHB
TMM6620R
TMMR6620R, TMM6620RF, TMMR6620RHB

Mini Mod III Factory Optional Lug Kit and Optional Compression Lug Kit
Phase
GE Lug Kit GE Lug Kit
Main Mini Mod Amp. Rating Wire Size Product Number Wire Size Product Number Lugs Per Kit
(3) #4-300 TMPAL40
TMM4312R, TMM4312RF 125
(2) 250-500 TMPAL30
(3) #4-300 TMPAL40
TMMR4312R, TMMR4312RF, TMMR4312RHB 125
(2) 250-500 TMPAL30
(3) #4-300 TMPAL40
TMM4412R, TMM4412RF 125
(2) 250-500 TMPAL30
(3) #4-300 TMPAL40
TMMR4412R, TMMR4412RF, TMMR4412RHB 125
(2) 250-500 TMPAL30
(3) #4-300 TMPAL40
TMM6512R, TMM6512RF 125
(1) 2/0-600 or (2) #6-250 TMPAL30
(3) #4-300 TMPAL40
TMMR6512R, TMMR6512RF, TMMR6512RHB 125
(1) 2/0-600 or (2) #6-250 TMPAL30
(3) #4-300 TMPAL40
TMM6612R, TMM6612RF 125
(1) 2/0-600 or (2) #6-250 TMPAL30
(3) #4-300 TMPAL40
TMMR6612R, TMMR6612RF, TMMR6612RHB 125
(1) 2/0-600 or (2) #6-250 TMPAL30 2 studs per phase,
(3) #4-300 TMPAL40 Compression TMM6CLL double stack for up to
TMM4220R 200
(1) 2/0-600 or (2) #6-250 TMPAL30 2 conductors per phase,
(3) #4-300 TMPAL40 kit includes 3 lug landing pads
TMMR4220R, TMMR4220RF, TMMR4220RHB 200
(1) 2/0-600 or (2) #6-250 TMPAL30 (1 kit per device)
(3) #4-300 TMPAL40
TMM6320R, TMM6320RF 200
(1) 2/0-600 or (2) #6-250 TMPAL30
(3) #4-300 TMPAL40
TMMR6320R, TMMR6320RF, TMMR6320RHB 200
(1) 2/0-600 or (2) #6-250 TMPAL30
(3) #4-300 TMPAL40
TMM6420R, TMM6420RF 200
(1) 2/0-600 or (2) #6-250 TMPAL30
(3) #4-300 TMPAL40
TMMR6420R, TMMR6420RF, TMMR6420RHB 200
(1) 2/0-600 or (2) #6-250 TMPAL30
(3) #4-300 TMPAL40
TMM6520R 200
(1) 2/0-600 or (2) #6-250 TMPAL30
(3) #4-300 TMPAL40
TMMR6520R, TMMR6520RF, TMMR6520RHB 200
(1) 2/0-600 or (2) #6-250 TMPAL30
(3) #4-300 TMPAL40
TMM6620R 200
(1) 2/0-600 or (2) #6-250 TMPAL30
(3) #4-300 TMPAL40
TMMR6620R, TMM6620RF, TMMR6620RHB 200
(1) 2/0-600 or (2) #6-250 TMPAL30

Rev. 11/13 www.geindustrial.com BuyLog Catalog 2-5


Data subject to change
without notice
Modular Metering Section 2
Mini Mod III
Accessories
Field Installed

Accessories - Field Installed


Product
Description Number
Semi-Flush Kits
-125A Sockets -2 gang TMM12SF2
-3 and 4 gang TMM12SF4
-5 and 6 gang TMM12SF6
-2 gang TMM20SF2
-200A Sockets -3 and 4 gang TMM20SF4
-5 and 6 gang TMM20SF6
Compression Lug Landing Kit -600 amp TMM6CLL
Includes 3 pads each with 2 threaded stud connections
(and hardware) for compression or mechanical lugs with
NEMA 2-hole bolt configuration (lugs not furnished).
Not suitable for 2-gang
By-pass Kits
Manual Slider-Type (Ring Type Only)1
-125 amp top socket for 2, 3, 5 and 6 gang TMBPM12TA
-125 amp for all other sockets TMBPM12A
-200 amp for all sockets TMBPM20A2
Jumper Straps Type1
(use with TMCA) TMBPJ204
Cover Including Jumper Strap Type-fits all
(Ring Type Only)3 TMBPC204
Horn-Type-fits all (Ringless Only)1 TMBPH20A
Fifth Jaw Kits
-Bused; 3, 6, or 9 o'clock mounting: TM5JA
Order two for fifth and sixth jaw. Not suitable for 2-gang ring type
-Isolated; 3 or 9 o'clock mounting TM5JUA
Sealing Rings
-Screw-Type, Aluminum TSR1
-Snap Type, Stainless Steel TSR3
-Screw and Lock-Type, Aluminum TSR4
-Snap-Type, Aluminum (Standard) TSR5
Steel Meter Socket Covers
Blank (fits bottom position only)
-125 Amp TMCB12B
-200 Amp TMCB20B
Ringless (Field -converts ring-type to ringless)
-125 amp top socket for 2 and 3 gang TMCR12T
-125 amp for all other sockets TMCR12
-200 amp for all sockets TMCR20
Lexan Meter socket Cover Plate (without tabs) TMCA
Lexan Meter Socket Cover Plate TMCP
Equipment Ground Bar, (6) 6-2/0 TMEG
Individual Meter Socket Barrier Kit (includes 6) TMBR
Mounting Z-Rail, 4-foot TMZR
Lug Kit for (3) 4/0 cable TMPAL40
1100 amps continuous.
2For top socket on TMM4220R, order TMBPM20TA.
3200 amps continuous.
4Not UL Listed.

2-6 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Page Updated 09 / 2016

Modular Metering Section 2


Meter Mod III Nomenclature
Product Number Systemsi

Product Number Guide for Meter Stack Modules


(Product number for illustrative purposes only)

T MP 3 8 6 20 T R F
GE Identification
Special
MEG Approved
Type
MP = Meter Mod Ring Type
Enclosures
MPR = Meter Mod Ringless
R = Type 3R rainproof
MPK = Meter Mod K-Base Socket

Insert for Tenant Breakers

Insert for 3-Phase Socket Rating


12 = 125A
20 = 200A
22 = 225A
40 = 400A
Horizontal Bus Rating
8 = 800A
12 = 1200A Socket Positions
1-6

Product Number Guide for Main Modules


(Product number for illustrative purposes only)

T MP 3 SB 8 R AR
GE Identification Additional Features
AR = Arc Reduction (For 1200A and greater
Type Main Breaker Type Main Modules only)
MP = Meter Mod III
CRIS = Copper, Riser

Insert for 3-Phase Enclosures


R = Type 3R Rainproof
Type CLL = Compression Lug Landing Kit Included
SB = Main Breaker, Top/Bottom Feed (400-1200A) ST = Shunt Trip, Factory Installed
SHB = Main Breaker, High Interrupting, Top/Bottom Feed (400-1200A)
BB = Main Breaker, Bottom Feed (1400-2000A) Maximum Ampere Rating
BT = Main Breaker, Top Feed (1400-2000A) 4 = 400A
BU = Main Breaker with Integral Pull Box - EUSERC 6 = 600A
FT = Main Switch, Top Feed 8 = 800A
FB = Main Switch, Bottom Feed 10 = 1000A
L = Main Lug 12 = 1200A
U = Main Pull Box 14 = 1400A
16 = 1600A
20 = 2000A

Rev. 11/13 www.geindustrial.com BuyLog Catalog 2-7


Data subject to change
without notice
Modular Metering Section 2
Meter Mod III
How to Order
Short Circuit Ratings

Product Features
UL Listed (details below)
Short Circuit Ratings through 100,000 Amps RMS symmetrical
Interchangeable Single and Three-phase Main and Meter Modules
Indoor/Outdoor Construction
Individual Meter Covers
11-inch Mounting Z-Rails Included
Numerous Accessories

Ordering Guidelines UL Standard Listing and File Numbers


Modular Metering Equipment UL Standard for Safety UL File No.
A. Determine available fault current
Meter Modules No. 67 PanelboardsE8741
B. Select the following:
Main Modules
1. Main Module (pages 2-11 through 2-18) -Breaker No. 489 Molded Case Circuit Breakers E11713
a. Choose type (Breaker, Switch, Switch with Pull Box, -Switch No. 98 Enclosed Switches E9565
-Lug No. 67 Panelboards E8741
Lug, or Pull Box) -Pull Box No. 869 Service Equipment E84701
b. Phase Tenant Main Breakers
c. Main Ampere Rating -THQL, TQD No. 489 Molded Case Circuit Breakers E11592
-THHQL, THQD No. 489 Molded Case Circuit Breakers E11592
d. Short Circuit Rating -TMQL, TMQD No. 489 Molded Case Circuit Breakers E11713
2. Meter Stack Modules (pages 2-19 through 2-23) Accessories
-Meter No. 414 Meter Sockets E8741
3. Tenant Breakers, Field Installed (pages 2-20 through 2-22)
-Other No. 67 Panelboards E8741
4. Accessories (pages 2-19 through 2-23)

Modular Metering System Short Circuit Rating -UL Listed


Available Short Circuit Current rms Main Module1 Meter Module Load Center Panelboard
Symmetrical Amperes @ 240 Volts AC Switch Breaker Lug Tenant Main Breaker Type Branch Breaker Type Branch Breaker Type
10,000 All All All THQL, TQD, TEB, TMQL, TMQD THQP, THQL THQL, THQB
22,000 All All All THHQL, THQD, TMQL, TMQD THQP, THQL THQL, THQB
42,000 All All All TMQL, TMQD THQP, THQL THQL, THQB
65,000 All 400-600A: TMPSHB All TMQD THQP, THQL THQL, THQB
800-1200A: TMPSB
100,000 All 400-600A: TMPSHB All TMQD THQP, THQL THQL, THQB
1Main Pull Box Module is UL Listed for use with and at the short circuit rating of main switch and breaker modules.

Short Circuit Interrupting Ratings References:


These panelboards have a maximum short circuit current rating of 100,000 RMS Dimensions and Knockouts Pages 2-26 through 2-29
Renewal Parts Catalog DET-388
symmetrical amperes, 240 volts AC maximum. The actual rating depends on the branch Construction Details Booklet DET-395
breakers and the main breaker, if any, installed in or ahead of the panelboard. The
correct combinations for various short circuit ratings follow. Any additional or replace-
ment breakers must be a General Electric type, as indicated, with equal or greater
interrupting capacity.
Maximum Short Circuit Rating, Main Circuit Breaker Branch Circuit Breaker
rms Symmetrical Amperes, When the breaker protecting the panelboard, And when the branch circuit breakers
240 Vac or 120/240 Vac separate or integral, is GE Type installed are GE Type
10,000 None, THQL, TQMV, SKH, THQP, THQL, THQLGF, TQD, THHQL,
SGD, SGH, SGL THQD, TMQD, TMQL
22,000 None, THHQL, THQMV, SKH, (300-1200A), THQP, THQL, THQLGF2,
SGD, SGH (125-600A) TQD, THHQL, THQD, TMQD, TMQL
42,000 TMQB, TMQL, 300V Class T Fuse (600A max.) THQP3, THQL, THQLGF2,
TQD, THHQL, THQD, TMQD, TMQL
65,000 SGD, SGH (125-600A) THQL, THHQL, TQD, THQD,
TMQB, TMQD, TMQL
100,000 TMQD, SGL (125-600A) THQP3, THQL, THQLGF2, TQD4,
THHQL, THQD4, TMQD, TMQL
100,000 300V Class T Fuse (400A max.) THQP3, THQL, THHQL, TQD5,
THQD5, TMQD, TMQL
215-30A only.
3Suitable as branch breaker when tenant main provided is: THQL, THHQL, TMQL, TQD, TMQD.
4100-200A, 2-pole only.
5125-225A, 2- and 3-pole only.

2-8 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Modular Metering Section 2
Meter Mod III
Modular Metering Series Ratings
125A Sockets

Series Ratings 400A-2000A 1PH (2P) Main Breakers to 2-Pole THQL/THHQL (70-125A) - 125A Sockets1
Meter Mod III Meter Mod III Main Series Rating Voltage Voltage of Approved For
Main Breaker Section Breaker Frame Phase of Main (AIC) of Main Tenant Modular Metering
TMPSB4R SGH 400 65,000
TMPSHB4R SGL 400 100,000
TMPSB6R SGH 600 65,000
TMPSHB6R SGL 600 1 100,000 208/120 Vac 120/240 Vac Yes
TMPSB8R SKH 800 65,000
TMPSB10R SKH 1000 65,000
TMPSB12R SKH 1200 65,000
TMPBB14R, TMPBT14R, TMPBB16R,
TMPBB16RST, TMPBT16R, TMPBT16RST, RGH 1 100,000 208/120 Vac 120/240 Vac No
TMPBT20R, TMPBB20R
1Does not include 60A THQL/THHQL Tenant Breaker (Use 70A Instead)

Series Ratings 400A-2000A 3PH (3P) Main Breakers to 2-Pole THQL/THHQL (70-125A) - 125A Sockets1
Meter Mod III Meter Mod III Main Series Rating Voltage Voltage of Approved For
Main Breaker Section Breaker Frame Phase of Main (AIC) of Main Tenant Modular Metering
TMP3SB4R SGH 400 65,000
TMP3SHB4R SGL 400 100,000
TMP3SB6R SGH 600 65,000
TMP3SHB6R SGL 600 3 100,000 208/120 Vac 120/240 Vac Yes
TMP3SB8R SKH 800 65,000
TMP3SB10R SKH 1000 65,000
TMP3SB12R SKH 1200 65,000
TMPBB14R, TMPBT14R, TMPBB16R,
TMPBB16RST, TMPBT16R, TMPBT16RST, RGH 3 100,000 208/120 Vac 120/240 Vac No
TMPBT20R, TMPBB20R
1Does not include 60A THQL/THHQL Tenant Breaker (Use 70A Instead)

Series Ratings 400A-2000A 1PH (2P) Main Fusible Switches to 2-Pole THQL/THHQL (70-125A) - 125A Sockets
Meter Mod III Main Meter Mod III Main Series Rating Voltage Voltage of Approved For
Fusible Switch Section Fuse Type Phase of Main (AIC) of Main Tenant Modular Metering
TMPFT4R T Fuse
TMPFB4R T Fuse
1 100,000 208/120 Vac 120/240 Vac Yes3
TMPFT6R T Fuse
TMPFB6R T Fuse
TMPFT8R T Fuse
TMPFB8R2 T or L Fuse
TMPFT12R2 T or L Fuse 1 100,000 208/120 Vac 120/240 Vac No
TMPFB12R2 T or L Fuse
TMPFB12RT T Fuse
2Field convertible to Class L fusing, no kit required
3Switches up to 600A rated for series rating at 42K and below; switches up to 400A rated for series rating from >42K 100K.

Series Ratings 400A-2000A 3PH (3P) Main Fusible Switches to 2-Pole THQL/THHQL (70-125A) - 125A Sockets
Meter Mod III Main Meter Mod III Main Series Rating Voltage Voltage of Approved For
Fusible Switch Section Fuse Type Phase of Main (AIC) of Main Tenant Modular Metering
TMP3FT4R T Fuse
TMP3FB4R T Fuse
3 100,000 208/120 Vac 120/240 Vac Yes3
TMP3FT6R T Fuse
TMP3FB6R T Fuse
TMP3FT8R2 T Fuse
TMP3FB8R T or L Fuse
TMP3FT12R2 T or L Fuse
3 100,000 208/120 Vac 120/240 Vac No
TMP3FB12R T or L Fuse
TMP3FB12RT T Fuse
TMP3FB12RST T or L Fuse
TMP3FT16R, TMP3FB16R, TMP3FB16RST,
L Fuse 3 100,000 208/120 Vac 120/240 Vac No
TMP3FT20R, TMP3FB20R, TMP3FB20RST
2Field convertible to Class L fusing, no kit required
3Switches up to 600A rated for series rating at 42K and below; switches up to 400A rated for series rating from >42K 100K.

Rev. 11/13 www.geindustrial.com BuyLog Catalog 2-9


Data subject to change
without notice
Modular Metering Section 2
Meter Mod III
Modular Metering Series Ratings
200A Sockets

Series Ratings 400A-2000A 1PH (2P) Main Breakers to 2-Pole TQD (100-200A) - 200A Sockets
Meter Mod III Meter Mod III Main Series Rating Voltage Voltage of Approved For
Main Breaker Section Breaker Frame Phase of Main (AIC) of Main Tenant Modular Metering
TMPSB4R SGH 400 65,000 Yes
TMPSHB4R SGL 400 100,000 No
TMPSB6R SGH 600 65,000 Yes
TMPSHB6R SGL 600 1 100,000 208/120 Vac 120/240 Vac No
TMPSB8R SKH 800 65,000 No
TMPSB10R SKH 1000 65,000 No
TMPSB12R SKH 1200 65,000 No
TMPBB14R, TMPBT14R, TMPBB16R,
TMPBB16RST, TMPBT16R, TMPBT16RST, RGH 1 100,000 208/120 Vac 120/240 Vac No
TMPBT20R, TMPBB20R

Series Ratings 400A-2000A 3PH (3P) Main Breakers to 2-Pole TQD (100-200A) - 200A Sockets
Meter Mod III Meter Mod III Main Series Rating Voltage Voltage of Approved For
Main Breaker Section Breaker Frame Phase of Main (AIC) of Main Tenant Modular Metering
TMP3SB4R SGH 400 65,000 Yes
TMP3SHB4R SGL 400 100,000 No
TMP3SB6R SGH 600 65,000 Yes
TMP3SHB6R SGL 600 3 100,000 208/120 Vac 120/240 Vac No
TMP3SB8R SKH 800 65,000 No
TMP3SB10R SKH 1000 65,000 No
TMP3SB12R SKH 1200 65,000 No
TMPBB14R, TMPBT14R, TMPBB16R,
TMPBB16RST, TMPBT16R, TMPBT16RST, RGH 3 100,000 208/120 Vac 120/240 Vac No
TMPBT20R, TMPBB20R

Series Ratings 400A-2000A 1PH (2P) Main Fusible Switches to 2-Pole TQD (100-200A) - 200A Sockets
Meter Mod III Main Meter Mod III Main Series Rating Voltage Voltage of Approved For
Fusible Switch Section Fuse Type Phase of Main (AIC) of Main Tenant Modular Metering
TMPFT4R T Fuse
TMPFB4R T Fuse
1 100,000 208/120 Vac 120/240 Vac Yes1
TMPFT6R T Fuse
TMPFB6R T Fuse
TMPFT8R T Fuse
TMPFB8R T or L Fuse
TMPFT12R L Fuse 1 100,000 208/120 Vac 120/240 Vac No
TMPFB12R L Fuse
TMPFB12RT T Fuse
1Switches up to 600A rated for series rating at 42K and below; switches up to 400A rated for series rating from >42K 100K.

Series Ratings 400A-2000A 3PH (3P) Main Fusible Switches to 2-Pole TQD (100-200A) - 200A Sockets
Meter Mod III Main Meter Mod III Main Series Rating Voltage Voltage of Approved For
Fusible Switch Section Fuse Type Phase of Main (AIC) of Main Tenant Modular Metering
TMP3FT4R T Fuse
TMP3FB4R T Fuse
3 100,000 208/120 Vac 120/240 Vac Yes1
TMP3FT6R T Fuse
TMP3FB6R T Fuse
TMP3FT8R T Fuse
TMP3FB8R T or L Fuse
TMP3FT12R L Fuse
3 100,000 208/120 Vac 120/240 Vac No
TMP3FB12R L Fuse
TMP3FB12RT T Fuse
TMP3FB12RST T or L Fuse
TMP3FT16R, TMP3FB16R, TMP3FB16RST,
L Fuse 3 100,000 208/120 Vac 120/240 Vac No
TMP3FT20R, TMP3FB20R, TMP3FB20RST
1Switches up to 600A rated for series rating at 42K and below; switches up to 400A rated for series rating from >42K 100K.

2-10 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Modular Metering Section 2
Meter Mod III
Main Breaker Modules
Single-Phase and Three-Phase

Single-Phase Mains have a neutral, A-Phase, B-Phase, and


Ground, and may be connected to Three-Phase horizontal
bus stacks. However, output is only single-phase.
All Mains are required to be center feed only when the main
circuit breaker rating is larger than the horizontal bus
amperage rating.

TMPSB4R
Main Breaker Single-Phase, Three-Wire 120/240 Vac
Breaker included, top or bottom feed. 80% Rated MCB.
Main Main Wire Size Product
Ampere Rating IC Rating (Max) Main Wire Size AWG/kcmil Cu/Al - Phase AWG/kcmil Cu/Al - Neutral Number
400 65 kAIC Al :(2) 2/0 - 500 or (1) 6 -600 Cu 2/0 - 400 or (1) 6 -600 (2) 2 -600 TMPSB4R
400 100 kAIC Al :(2) 2/0 - 500 or (1) 6 -600 Cu 2/0 - 400 or (1) 6 -600 (2) 2 -600 TMPSHB4R
600 65 kAIC Al :(2) 2/0 - 500 or (1) 6 -600 Cu 2/0 - 400 or (1) 6 -600 (2) 2 -600 TMPSB6R
600 100 kAIC Al :(2) 2/0 - 500 or (1) 6 -600 Cu 2/0 - 400 or (1) 6 -600 (2) 2 -600 TMPSHB6R
800 65 kAIC Al/Cu (3) 3/0 -5001 (4) 250-5002 TMPSB8R
1000 65 kAIC Al(4) 250-500 CU(4) 250/3501 (4) 250-5002 TMPSB10R
1200 65 kAIC Al(4) 250-500 CU(4) 250/3501 (4) 250-5002 TMPSB12R7
1400 100 kAIC (4) 500-1000 kcmil Al/Cu (4) 500-1000 TMPBB14R4,6
1400 100 kAIC (4) 500-1000 kcmil Al/Cu (4) 500-1000 TMPBT14R5,6
1600 100 kAIC Al/Cu (4) 500-1000 kcmil Al/Cu (4) 500-1000 TMPBB16R4,6
1600 100 kAIC Al/Cu (4) 500-1000 kcmil Al/Cu (4) 500-1000 TMPBB16RST3,4,6
1600 100 kAIC Al/Cu (4) 500-1000 kcmil Al/Cu (4) 500-1000 TMPBT16R5,6
1600 100 kAIC Al/Cu (4) 500-1000 kcmil Al/Cu (4) 500-1000 TMPBT16RST3,5,6
2000 100 kAIC (6) #2 600 kcmil (6) #2 600 kcmil TMPBT20R5,6
2000 100 kAIC (6) #2 600 kcmil (6) #2 600 kcmil TMPBB20R4,6

Main Breaker Single-Phase, Three-Wire 120/240 Vac with Arc Reduction Means
The main breaker in this section has an arc reduction means that satisfies the requirement of NEC 2014 Section 240.87
Main Main Wire Size Product
Ampere Rating IC Rating (Max) Feed Main Wire Size AWG/kcmil Cu/Al - Phase AWG/kcmil Cu/Al - Neutral Number
Use Standard Part #.
400 to less than 1200 Top or Bottom Code effects only 1200A
and greater
Use 1400 or 1600A and advise GE
1200 Top or Bottom
sales rep to make trip unit 1200A
1400 100 kAIC Bottom (4) 500-1000 (4) 250-500 TMPBB14RAR
Bottom TMPBB16RAR
1600 100 kAIC (4) 500-1000 (4) 500-1000
Top TMPBT16RAR
2000 100 kAIC Bottom (6) #2-600 (6) #2-600 TMPBB20RAR

NOTE: These main sections use type RG Breakers. These breakers no longer have rating plugs; they have factory installed trip units. If
you need a trip setting that is different than the frame (For example, if you need a TMPBB16RAR 1600A frame with a 1200A trip), please
inform your GE sales rep at time of order entry. A request will be made to have this manually changed at the factory.

1Optional lug TCAL124 field installed wire range (3) 300-750 kcmil.
2Optional neutral lug field installed wire range (3) 1/0-750 kcmil.
Lug kit part number TMPL750.
3Includes 110-240 Vac shunt trip.
4Bottom feed.
5Top feed.
6Fixed Rating Plug not Field adjustable.
7To meet NEC 2014 Arc Energy Reduction (Section 240.87), please use a 1175A
rating plug. Product Number SRPK1200A1175, order separately.

Rev. 11/13 www.geindustrial.com BuyLog Catalog 2-11


Data subject to change
without notice
Modular Metering Section 2
Meter Mod III
Main Breaker Modules
Single-Phase and Three-Phase

Main Breaker Three-Phase, Four-Wire / Single-Phase, Three-Wire 120/240 Vac, 208Y/120 Vac
Breaker included, top or bottom feed. 80% Rated MCB
Main Main Wire Size Product
Ampere Rating IC Rating (Max) Main Wire Size AWG/kcmil Cu/Al - Phase AWG/kcmil Cu/Al - Neutral Number
400 65 kAIC Al :(2) 2/0 - 500 or (1) 6 -600 Cu 2/0 - 400 or (1) 6 -600 (2) 2 -600 TMP3SB4R
400 100 kAIC Al :(2) 2/0 - 500 or (1) 6 -600 Cu 2/0 - 400 or (1) 6 -600 (2) 2 -600 TMP3SHB4R
600 65 kAIC Al :(2) 2/0 - 500 or (1) 6 -600 Cu 2/0 - 400 or (1) 6 -600 (2) 2 -600 TMP3SB6R
600 100 kAIC Al :(2) 2/0 - 500 or (1) 6 -600 Cu 2/0 - 400 or (1) 6 -600 (2) 2 -600 TMP3SHB6R
800 65 kAIC Al/Cu (3) 3/0 -5001 (4) 250-5002 TMP3SB8R
1000 65 kAIC Al(4) 250-500 Cu(4) 250/3501 (4) 250-5002 TMP3SB10R
1200 65 kAIC Al(4) 250-500 Cu(4) 250/3501 (4) 250-5002 TMP3SB12R9
1400 100 kAIC (4) 500-1000 kmcil (4) 500-1000 kmcil TMP3BB14R4,7
1400 100 kAIC (4) 500-1000 kmcil (4) 500-1000 kmcil TMP3BT14R5,7
1600 100 kAIC Al/Cu (4) 500-1000 Al/Cu (4) 500-1000 TMP3BB16R4,7
1600 100 kAIC Compression Lugs Compression Lugs TMP3BB16RCLL4,7
1600 100 kAIC Al/Cu (4) 500-1000 Al/Cu (4) 500-1000 TMP3BB16RST3,4,7
1600 100 kAIC Al/Cu (4) 500-1000 Al/Cu (4) 500-1000 TMP3BT16R5,7
1600 100 kAIC Al/Cu (4) 500-1000 Al/Cu (4) 500-1000 TMP3BT16RST3.5.7
2000 100 kAIC (6) #2-600 kcmil (6) #2-600 kcmil TMP3BT20R5,7
2000 100 kAIC (6) #2-600 kcmil (6) #2-600 kcmil TMP3BB20R4,7
2000 100 kAIC Compression Lugs Compression Lugs TMP3BB20RCLL4,7
2000 100 kAIC (6) #2-600 kcmil (6) #2-600 kcmil TMP3BT20RST3,5,7
2000 100 kAIC (6) #2-600 kcmil (6) #2-600 kcmil TMP3BB20RST3,4,7

Main Breaker Three-Phase, Four-Wire 208Y/120 Vac or Three-Phase, Four-Wire 120/240 Vac,
Delta Hi-Leg with Arc Reduction Means
The main breaker in this section has an arc reduction means that satisfies the requirement of NEC 2014 Section 240.87
Main Main Wire Size Product
Ampere Rating IC Rating (Max) Feed Main Wire Size AWG/kcmil Cu/Al - Phase AWG/kcmil Cu/Al - Neutral Number
Use Standard Part #.
400 to less than 1200 Top or Bottom Code effects only 1200A
and greater
Use 1400 or 1600A and advise GE
1200 Top or Bottom
sales rep to make trip unit 1200A
Bottom TMP3BB14RAR
1400 100 kAIC (4) 500-1000 (4) 500-1000
Top TMP3BT14RAR
Bottom TMP3BB16RAR
1600 100 kAIC (4) 500-1000 (4) 500-1000
Top TMP3BT16RAR
Top TMP3BT20RAR
2000 100 kAIC (6) #2-600 (6) #2-600
Bottom TMP3BB20RAR

NOTE: These main sections use type RG Breakers. These breakers no longer have rating plugs; they have factory installed trip units. If
you need a trip setting that is different than the frame (For example, if you need a TMP3BB16RAR 1600A frame with a 1200A trip),
please inform your GE sales rep at time of order entry. A request will be made to have this manually changed at the factory.
Main Breaker Modules Shunt-Trip - Field Installed
Alternate Rating Plugs Field Installed8 For Use on all Main Breaker Modules
Product Product
Main Ampere Rating Alternate Rating Number Shunt Trip Number

4006 225 SRPG400A225 120 Vac SAST1


4006 250 SRPG400A250 240 Vac SAST2
4006 300 SRPG400A300 1Optional lug TCAL124 field installed wire range (3) 300-750 kcmil.
4006 350 SRPG400A350 2Optional neutral lug field installed wire range (3) 1/0-750 kcmil.
600 400 SRPG600A400
600 450 SRPG600A450 Lug kit part number TMPL750.
3Includes 110-240 Vac shunt trip.
600 500 SRPG600A500
800 600 SRPK800A600 4Bottom feed.
800 700 SRPK800A700 5Top feed.
1000 800 SRPK1200A800 6Alternate for 400A frame.
1200 1000 SRPK1200A1000 7Fixed Rating Plug not Field adjustable.
8 Not available for 1400, 1600, and 2000A Mains
9 To meet NEC 2014 Arc Energy Reduction (Section 240.87), please use a 1175A
rating plug. Product Number SRPK1200A1175, order separately.

2-12 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Modular Metering Section 2
Meter Mod III
Main Breaker Modules
Single-Phase and Three-Phase

Factory Installed Lug Kit


Phase Neutral
Main Amp GE Lug Kit Total Lugs
Breaker Rating Wire Size Wire Size Product No. Lugs Per Kit Per Device
TMPSB4R 400 AL:(2) 2/0-500 or (1) 6-600 Cu 2/0-400 or (1) 6-600 (2) 2-600 TCLK265 2 lugs per kit
TMP3SB4R 400 AL:(2) 2/0-500 or (1) 6-600 Cu 2/0-400 or (1) 6-600 (2) 2-600 TCLK365 3 lugs per kit
TMPSHB4R 400 AL:(2) 2/0-500 or (1) 6-600 Cu 2/0-400 or (1) 6-600 (2) 2-600 TCLK265 2 lugs per kit
TMP3SHB4R 400 AL:(2) 2/0-500 or (1) 6-600 Cu 2/0-400 or (1) 6-600 (2) 2-600 TCLK365 3 lugs per kit
TMPSB6R 600 AL:(2) 2/0-500 or (1) 6-600 Cu 2/0-400 or (1) 6-600 (2) 2-600 TCLK265 2 lugs per kit
TMP3SB6R 600 AL:(2) 2/0-500 or (1) 6-600 Cu 2/0-400 or (1) 6-600 (2) 2-600 TCLK365 3 lugs per kit
TMPSHB6R 600 AL:(2) 2/0-500 or (1) 6-600 Cu 2/0-400 or (1) 6-600 (2) 2-600 TCLK265 2 lugs per kit
TMP3SHB6R 600 AL:(2) 2/0-500 or (1) 6-600 Cu 2/0-400 or (1) 6-600 (2) 2-600 TCLK365 3 lugs per kit
TMPSB8R 800 AL/Cu (3) 3/0-500 (4) 250-500 TCAL124 1 lug per kit
TMP3SB8R 800 AL/Cu (3) 3/0-500 (4) 250-500 TCAL124 1 lug per kit
TMPSB10R 1000 Al(4) 250-500 Cu(4) 250/350 (4) 250-500 TCAL125 1 lug per kit
TMP3SB10R 1000 Al(4) 250-500 Cu(4) 250/350 (4) 250-500 TCAL125 1 lug per kit
TMPSB12R 1200 Al(4) 250-500 Cu(4) 250/350 (4) 250-500 TCAL125 1 lug per kit
TMP3SB12R 1200 Al(4) 250-500 Cu(4) 250/350 (4) 250-500 TCAL125 1 lug per kit
TMPBB14R 1400 Al/Cu (4) 500-1000 Al/Cu (4) 500-1000 TMPL1600RD 1 lug per kit, 4 holes per lug 3 lugs per device
TMPBT14R 1400 Al/Cu (4) 500-1000 Al/Cu (4) 500-1000 TMPL1600RD 1 lug per kit, 4 holes per lug 3 lugs per device
TMP3BB14R 1400 Al/Cu (4) 500-1000 Al/Cu (4) 500-1000 TMPL1600RD 1 lug per kit, 4 holes per lug 4 lugs per device
TMP3BT14R 1400 Al/Cu (4) 500-1000 Al/Cu (4) 500-1000 TMPL1600RD 1 lug per kit, 4 holes per lug 4 lugs per device
TMPBB16R 1600 Al/Cu (4) 500-1000 Al/Cu (4) 500-1000 TMPL1600RD 1 lug per kit, 4 holes per lug 3 lugs per device
TMP3BB16R 1600 Al/Cu (4) 500-1000 Al/Cu (4) 500-1000 TMPL1600RD 1 lug per kit, 4 holes per lug 4 lugs per device
TMPBB16RST 1600 Al/Cu (4) 500-1000 Al/Cu (4) 500-1000 TMPL1600RD 1 lug per kit, 4 holes per lug 3 lugs per device
TMP3BB16RST 1600 Al/Cu (4) 500-1000 Al/Cu (4) 500-1000 TMPL1600RD 1 lug per kit, 4 holes per lug 4 lugs per device
TMPBT16R 1600 Al/Cu (4) 500-1000 Al/Cu (4) 500-1000 TMPL1600RD 1 lug per kit, 4 holes per lug 3 lugs per device
TMP3BT16R 1600 Al/Cu (4) 500-1000 Al/Cu (4) 500-1000 TMPL1600RD 1 lug per kit, 4 holes per lug 4 lugs per device
TMPBT16RST 1600 Al/Cu (4) 500-1000 Al/Cu (4) 500-1000 TMPL1600RD 1 lug per kit, 4 holes per lug 3 lugs per device
TMP3BT16RST 1600 Al/Cu (4) 500-1000 Al/Cu (4) 500-1000 TMPL1600RD 1 lug per kit, 4 holes per lug 4 lugs per device
TMPBB20R 2000 Al/Cu (6) #2-600 Al/Cu (6) #2-600 TMPL2000RD 9 lugs per kit 6 lugs per device, 3 lugs/neutral
TMP3BB20R 2000 Al/Cu (6) #2-600 Al/Cu (6) #2-600 TMPL2000RD 9 lugs per kit 9 lugs per device, 3 lugs/neutral
TMPBT20R 2000 Al/Cu (6) #2-600 Al/Cu (6) #2-600 TMPL2000RD 9 lugs per kit 6 lugs per device, 3 lugs/neutral
TMP3BT20R 2000 Al/Cu (6) #2-600 Al/Cu (6) #2-600 TMPL2000RD 9 lugs per kit 9 lugs per device, 3 lugs/neutral

Optional Lug Kit


Phase Neutral
Main Amp GE Lug Kit GE Lug GE Lug Kit
Breaker Rating Wire Size Product No. Product No. Lugs Per Kit Wire Size Product No.
TMPBB14R 1400 (6) #2-600 TMPL2000RD N/A 9 (6) #2-600 TMBP2000N
TMPBT14R 1400 (6) #2-600 TMPL2000RD N/A 9 (6) #2-600 TMBP2000N
TMP3BB14R 1400 (6) #2-600 TMPL2000RD N/A 9 (6) #2-600 TMBP2000N
TMP3BT14R 1400 (6) #2-600 TMPL2000RD N/A 9 (6) #2-600 TMBP2000N
TMPBB16R 1600 (6) #2-600 TMPL2000RD N/A 9 (6) #2-600 TMBP2000N
TMP3BB16R 1600 (6) #2-600 TMPL2000RD N/A 9 (6) #2-600 TMBP2000N
TMPBB16RST 1600 (6) #2-600 TMPL2000RD N/A 9 (6) #2-600 TMBP2000N
TMP3BB16RST 1600 (6) #2-600 TMPL2000RD N/A 9 (6) #2-600 TMBP2000N
TMPBT16R 1600 (6) #2-600 TMPL2000RD N/A 9 (6) #2-600 TMBP2000N
TMP3BT16R 1600 (6) #2-600 TMPL2000RD N/A 9 (6) #2-600 TMBP2000N
TMPBT16RST 1600 (6) #2-600 TMPL2000RD N/A 9 (6) #2-600 TMBP2000N
TMP3BT16RST 1600 (6) #2-600 TMPL2000RD N/A 9 (6) #2-600 TMBP2000N

Rev. 11/13 www.geindustrial.com BuyLog Catalog 2-13


Data subject to change
without notice
Modular Metering Section 2
Meter Mod III
Main Fusible Modules
Single-Phase and Three-Phase

Single-Phase Mains have a neutral, A-Phase, B-Phase, and Ground,


and may be connected to Three-Phase horizontal bus stacks.
However, output is only single-phase.
All Mains are required to be center feed only when the main fusible
switch rating is larger than the horizontal bus amperage rating.

TMPFB6R

Main Fusible Switch Single-Phase, Three-Wire 120/240 Vac


T-Fuses not included (available from table on page 2-18).
Main Main Wire Size Main Wire Size Stud sets
Ampere IC Rating AWG/kcmil AWG/kcmil per Phase Compression Product
Wire Entry Rating (Max) Cu/Al - Phase Cu/Al - Neutral and Neutral Lug Landing Kit2 Number
Top 400 100 kAIC (1) 1/0-750 or (2) 1/0 -300 (1) 1/0-750 or (2) 1/0 -300 1 Order Separately TMPFT4R1
Top 600 100 kAIC (2) 2- 600 (2) 2- 600 1 Order Separately TMPFT6R1
Top 800 100 kAIC (4) 3/0-750 (4) 3/0-750 1 Order Separately TMPFT8R1
Top 1200 100 kAIC (4) 2-500 (4) 2-500 TMPFT12R2
Bottom 400 100 kAIC (1) 1/0-750 or (2) 1/0 -300 (1) 1/0-750 or (2) 1/0 -300 1 Order Separately TMPFB4R1
Bottom 600 100 kAIC (2) 2- 600 (2) 2- 600 1 Order Separately TMPFB6R1
Bottom 800 100 kAIC (4) 3/0-750 (4) 3/0-750 1 Order Separately TMPFB8R1
Bottom 1200 100 kAIC (4) 2-600 (4) 2-600 TMPFB12RT3
Bottom 1200 100 kAIC (4) 2-500 (4) 2-500 TMPFB12R4

Main Fusible Switch Three-Phase, Four-Wire / Single-Phase, Three-Wire 120/240 Vac, 208Y/120 Vac, 240/120 Vac
T-Fuses not included (available from table on page 2-18).
Main Main Wire Size Main Wire Size Stud sets
Ampere IC Rating AWG/kcmil AWG/kcmil per Phase Compression Product
Wire Entry Rating (Max) Cu/Al - Phase Cu/Al - Neutral and Neutral Lug Landing Kit2 Number
Top 400 100 kAIC (1) 1/0-750 or (2) 1/0 -300 (1) 1/0-750 or (2) 1/0 -300 1 Order Separately TMP3FT4R1
Top 600 100 kAIC (2) 2- 600 (2) 2- 600 1 Order Separately TMP3FT6R1
Top 800 100 kAIC (4) 3/0-750 (4) 3/0-750 1 Order Separately TMP3FT8R1
Top 1200 100 kAIC (4) 4-600 (4) 4-600 TMP3FT12R2
Top 1600 100 kAIC (6) 4-600 (6) 4-600 TMP3FT16R2
Top 2000 100 kAIC (8) 4-600 (8) 4-600 TMP3FT20R2
Bottom 400 100 kAIC (1) 1/0-750 or (2) 1/0 -300 (1) 1/0-750 or (2) 1/0 -300 1 Order Separately TMP3FB4R1
Bottom 600 100 kAIC (2) 2- 600 (2) 2- 600 1 Order Separately TMP3FB6R1
Bottom 800 100 kAIC (4) 3/0-750 (4) 3/0-750 1 Order Separately TMP3FB8R1
Bottom 1200 100 kAIC (4) 2-600 (4) 2-600 TMP3FB12RT5
Bottom 1200 100 kAIC (4) 4-600 (4) 4-600 TMP3FB12R6
Bottom 1600 100 kAIC (6) 4-600 (6) 4-600 TMP3FB16R2
Bottom 2000 100 kAIC (8) 4-600 (8) 4-600 TMP3FB20R2
Bottom 1200 100 kAIC (4) 4-600 (4) 4-600 TMP3FB12RST2,7
Bottom 1600 100 kAIC (6) 4-600 (6) 4-600 TMP3FB16RST2,7
Bottom 2000 100 kAIC (8) 4-600 (8) 4-600 TMP3FB20RST2,7
1Class T fuse only.
2Class L fuse only. Bolted pressure switch.
3TMPFB12RT is a standard fusible switch that uses only Class T fuses. This unit is less robust and smaller than the TMPFB12R, but is significantly less expensive.
4TMPFB12R is a bolted pressure switch that uses only Class L fuses. This unit is larger and more robust than the TMPFB12RT, but more expensive.
5TMP3FB12RT is a standard fusible switch that uses only Class T fuses. This unit is less robust and smaller than the TMP3FB12R, but is significantly less expensive.
6TMP3FB12R is a bolted pressure switch that uses only Class L fuses. This unit is larger and more robust than the TMP3FB12RT, but more expensive.
7Product numbers ending in ST have shunt tripping style bolted pressure switch.

2-14 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Modular Metering Section 2
Meter Mod III
Main Fusible Modules
Single-Phase and Three-Phase

Factory Installed Lug Kit


Main Amp Phase Neutral GE Lug Kit Lugs
Switch Rating Wire Size Wire Size Product No. Per Kit
TMPFT4R 400 (1) 1/0-750 or (2) 1/0-300 (1) 1/0-750 or (2) 1/0-300
TMP3FT4R 400 (1) 1/0-750 or (2) 1/0-300 (1) 1/0-750 or (2) 1/0-300
TMPFT6R 600 (2) 2-600 (2) 2-600
TMP3FT6R 600 (2) 2-600 (2) 2-600
TMPFT8R 800 (4) 3/0-750 (4) 3/0-750 TMPL40 1 lug per kit, 4 holes per lug
TMP3FT8R 800 (4) 3/0-750 (4) 3/0-750 TMPL40 1 lug per kit, 4 holes per lug
TMPFT12R 1200 (4) 2-500 (4) 2-500
TMP3FT12R 1200 (4) 2-600, 2 lugs per phase (4) 2-600
TMPFB4R 400 (1) 1/0-750 or (2) 1/0-300 (1) 1/0-750 or (2) 1/0-300
TMP3FB4R 400 (1) 1/0-750 or (2) 1/0-300 (1) 1/0-750 or (2) 1/0-300
TMPFB6R 600 (2) 2-600 (2) 2-600
TMP3FB6R 600 (2) 2-600 (2) 2-600
TMP3FB8R 800 (4) 3/0-750 (4) 3/0-750 TMPL40 1 lug per kit, 4 holes per lug
TMP3FB8R 800 (4) 3/0-750 (4) 3/0-750 TMPL40 1 lug per kit, 4 holes per lug
TMPFB12R 1200 (4) 2-500 (4) 2-500
TMP3FB12R 1200 (8) 2-600, (4 lugs, 2-holes per lug)
TMPFB12RT 1200 (4) 2-600, 2 lugs per phase (4) 2-600
TMP3FB12RT 1200 (4) 2-600, 2 lugs per phase (4) 2-600
TMP3FT16R 1600 (5) 4-600 (5) 4-600
TMP3FB16R 1600 (8) 2-600 (8) 2-600
TMP3FT20R 2000 (6) 4-600 (6) 4-600
TMP3FB20R 2000 (8) 2-600 (8) 2-600
TMPFB4RCLL 400 Accepts compression lugs, 1 landings per phase
TMP3FB4RCLL 400 Accepts compression lugs, 1 landings per phase
TMPFB6RCLL 600 Accepts compression lugs, 2 landings per phase
TMP3FB6RCLL 600 Accepts compression lugs, 2 landings per phase
TMPFB8RCLL 800 Accepts compression lugs, 2 landings per phase
TMP3FB8RCLL 800 Accepts compression lugs, 2 landings per phase
TMPFB12RCLLT 1200 Accepts compression lugs, 3 landings per phase
TMP3FB12RCLLT 1200 Accepts compression lugs, 3 landings per phase

Optional Lug Kit: Phase Optional Lug Kit: Compression


Main Amp Wire GE Lug Kit Wire GE Lug Kit
Switch Rating Size Product No. Size Product No.
TMPFT4R 400 (4) 3/0-750, 4 cables per lug TMPL40 Compression TMP3F8CLL1
TMP3FT4R 400 (4) 3/0-750, 4 cables per lug TMPL40 Compression TMP3F8CLL1
TMPFT6R 600 (4) 3/0-750, 4 cables per lug TMPL40 Compression TMP3F8CLL1
TMP3FT6R 600 (4) 3/0-750, 4 cables per lug TMPL40 Compression TMP3F8CLL1
TMPFT8R 800 Not available Not available Compression TMP3F8CLL1
TMP3FT8R 800 Not available Not available Compression TMP3F8CLL1
TMPFB4R 400 (4) 3/0-750, 4 cables per lug TMPL40 Compression TMP3F8CLL1
TMP3FB4R 400 (4) 3/0-750, 4 cables per lug TMPL40 Compression TMP3F8CLL1
TMPFB6R 600 (4) 3/0-750, 4 cables per lug TMPL40 Compression TMP3F8CLL1
TMP3FB6R 600 (4) 3/0-750, 4 cables per lug TMPL40 Compression TMP3F8CLL1
TMP3FB8R 800 Not available Not available Compression TMP3F8CLL1
TMP3FB8R 800 Not available Not available Compression TMP3F8CLL1

Rev. 11/13 www.geindustrial.com BuyLog Catalog 2-15


Data subject to change
without notice
Modular Metering Section 2
Meter Mod III
Main Fusible w/Pull Box and Main Lug Modules
Single-Phase and Three-Phase

TMP3L6R
Main Fusible Switch w/Integral Pull Box Single-Phase, Three-Wire 120/240 Vac
End or center mounting. Lugs not included. Meets EUSERC requirements. When meter stacks are to be mounted on handle side of
switch order TMPS12 spacer. All modules accept Class T fuse.
Main IC Rating Main Wire Size Main Wire Size Compression Lug Product
Wire Entry Ampere Rating (Max) AWG/kcmil Cu/Al - Phase AWG/kcmil Cu/Al - Neutral Landing Kit Number
Bottom 400 100 kAIC Compression Lug Landing Kit Included Compression Lug Landing Kit Included Included TMPFB4RCLL
(NEMA 2-Hole Spacing) (NEMA 2-Hole Spacing)
Bottom 600 100 kAIC Compression Lug Landing Kit Included Compression Lug Landing Kit Included Included TMPFB6RCLL
(NEMA 2-Hole Spacing) (NEMA 2-Hole Spacing)
Bottom 800 100 kAIC Compression Lug Landing Kit Included Compression Lug Landing Kit Included Included TMPFB8RCLL
(NEMA 2-Hole Spacing) (NEMA 2-Hole Spacing)
Bottom 12001 100 kAIC Compression Lug Landing Kit Included Compression Lug Landing Kit Included Included TMPFB12RCLLT
(NEMA 2-Hole Spacing) (NEMA 2-Hole Spacing)

Main Fusible Switch w/Integral Pull Box Three-Phase, Four-Wire / Single-Phase, Three-Wire 120/240 Vac, 208Y/120 Vac, 240/120 Vac
End or center mounting. Lugs not included. Meets EUSERC requirements. When meter stacks are to be mounted on handle side of
switch, order TMPS12 spacer. All modules accept Class T fuse.
Main IC Rating Main Wire Size Main Wire Size Compression Lug Product
Wire Entry Ampere Rating (Max) AWG/kcmil Cu/Al - Phase AWG/kcmil Cu/Al - Neutral Landing Kit Number
Bottom 400 100 kAIC Compression Lug Landing Kit Included Compression Lug Landing Kit Included Included TMP3FB4RCLL
(NEMA 2-Hole Spacing) (NEMA 2-Hole Spacing)
Bottom 600 100 kAIC Compression Lug Landing Kit Included Compression Lug Landing Kit Included Included TMP3FB6RCLL
(NEMA 2-Hole Spacing) (NEMA 2-Hole Spacing)
Bottom 800 100 kAIC Compression Lug Landing Kit Included Compression Lug Landing Kit Included Included TMP3FB8RCLL
(NEMA 2-Hole Spacing) (NEMA 2-Hole Spacing)
Bottom 1200 100 kAIC Compression Lug Landing Kit Included Compression Lug Landing Kit Included Included TMP3FB12RCLLT
(NEMA 2-Hole Spacing) (NEMA 2-Hole Spacing)

Main Lug Single-Phase, Three-Wire 120/240 Vac


End or center mounting. Lugs included.
Main IC Rating2 Main Wire Size Main Wire Size Stud sets per Phase Compression Lug Product
Wire Entry Ampere Rating (Max) AWG/kcmil Cu/Al - Phase AWG/kcmil Cu/Al - Neutral and Neutral Landing Kit Number
Bottom / Top 400 Use 3-Phase
Bottom / Top 600 Use 3-Phase
Bottom/Top 800 100 kAIC (2) 1/0-750 or (4) 1/0 -300 (2) 1/0-750 or (4) 1/0 -300 2 Order Separately TMPL8R
Bottom/Top 1200 100 kAIC (3) 1/0-750 or (6) 1/0-300 (3) 1/0-750 or (6) 1/0 -300 3 Order Separately TMPL12R
Bottom/Top 1600 100 kAIC (6) 250-500 (6) 250-500 3 Order Separately TMPL16R

Main Lug Three-Phase, Four-Wire / Single-Phase, Three-Wire 120/240 Vac, 208Y/120 Vac
End or center mounting. Lugs included.
Main IC Rating2 Main Wire Size Main Wire Size Stud sets per Phase Compression Lug Product
Wire Entry Ampere Rating (Max) AWG/kcmil Cu/Al - Phase AWG/kcmil Cu/Al - Neutral and Neutral Landing Kit Number
Bottom/Top 400 100 kAIC (1) 6-600 or (2) 1/0-250 (1) 6-600 or (2) 1/0-250 1 Order Separately TMP3L4R
Bottom/Top 400 100 kAIC (1) 6-600 or (2) 1/0-250 (1) 6-600 or (2) 1/0-250 1 Order Separately TMP3L4RCU3
Bottom/Top 600 100 kAIC (2) 250-500 (2) 250-500 1 Order Separately TMP3L6R
Bottom/Top 600 100 kAIC (2) 250-500 (2) 250-500 1 Order Separately TMP3L6RCU3
Bottom/Top 800 100 kAIC (2) 1/0-750 or (4) 1/0-300 (2) 1/0-750 or (4) 1/0 -300 2 Order Separately TMP3L8R
Bottom/Top 800 100 kAIC (2) 1/0-750 or (4) 1/0-300 (2) 1/0-750 or (4) 1/0 -300 2 Order Separately TMP3L8RCU3
Bottom/Top 1200 100 kAIC (3) 1/0-750 or (6) 1/0-300 (3) 1/0-750 or (6) 1/0 -300 2 Order Separately TMP3L12R
Bottom/Top 1600 100 kAIC (6) 250-500 (6) 250-500 2 Order Separately TMP3L16R

Main Lug with Feed Through, Three Phase, Four Wire / Single Phase, Three Wire 120/240 Vac, 208Y/120 Vac
Main IC Rating Stud sets per Phase Compression Lug Product
Wire Entry Ampere Rating (Max) Incoming Line Outgoing Load and Neutral Landing Kit Number
Bottom/Top 1200 100 kAIC (5) Up to 750 MCM (5) Up to 750 MCM 2 TMP3L12RCRIS
per Phase/Neutral (AL/CU) per Phase/Neutral (AL/CU)
Bottom/Top 1600 100 kAIC (5) Up to 750 MCM (5) Up to 750 MCM 2 TMP3L16RCRIS
per Phase/Neutral (AL/CU) per Phase/Neutral (AL/CU)
1Center-feed only for single-phase meter modules with 800A horizontal bus rating.
2Limited to the lowest marked short circuit rating of the main and meter modules used.
3Copper bus.

2-16 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Modular Metering Section 2
Meter Mod III
Main Lug Modules
Single-Phase and Three-Phase

Factory Installed Lug Kit


Main Lug Amp Phase Neutral GE Lug Kit Total Lugs
(Terminal Box) Rating Wire Size Wire Size Product No. Lugs Per Kit Per Device
TMP3L4R 400 (1) 2/0-600 or (2) #6-250 (1) 2/0-600 or (2) #6-250 TMMLK1(w/ instr) 1 lug/kit, 1 lug per phase, 2 hole lug
TMP3L6R 600 (2) 250-500 per lug (2) 250-500 per lug TMPAL30 1 lug per kit, 1 lug per phase
TMPL8R 800 (2) 1/0-750 or (4) 1/0-300 (2) 1/0-750 or (4) 1/0-300 TMPL750 2 lugs per phase, 3 lugs per kit
TMP3L8R 800 (2) 1/0-750 or (4) 1/0-300 (2) 1/0-750 or (4) 1/0-300 TMPL750 2 lugs per phase, 3 lugs per kit
TMPL12R 1200 (3) 1/0-750 or (6) 1/0-300 (3) 1/0-750 or (6) 1/0-300 TMPL750 3 lugs per phase, 3 lugs per kit
TMP3L12R 1200 (3) 1/0-750 or (6) 1/0-300 (3) 1/0-750 or (6) 1/0-300 TMPL750 3 lugs per phase, 3 lugs per kit
TMPL16R 1600 (6) 250-500 (6) 250-500 TMPAL30 1 lug per kit, 3 lugs per phase 9 lugs total
TMP3L16R 1600 (6) 250-500 (6) 250-500 TMPAL30 1 lug per kit, 3 lugs per phase 12 lugs total

Optional Lug Kit: Phase Optional Lug Kit: Compression


Main Lug Amp Wire GE Lug Kit Wire GE Lug Kit
(Terminal Box) Rating Size Product No. Lugs Per Kit Size Product No. Lugs Per Kit
2 studs per phase, double stack
TMP3L4R 400 (2) 250-500 per lug TMPAL30 1 lug per kit, 1 lug per phase Compression TMP3L6CLL
for up to 2 conductors per phase
2 studs per phase, double stack
TMP3L6R 600 Not available Compression TMP3L6CLL
for up to 2 conductors per phase
4 studs per phase, double stack
TMPL8R 800 (2) 250-500 TMPAL30 1 lug per kit, 1 lug per phase Compression TMP3L12CLL1
for up to 4 conductors per phase
4 studs per phase, double stack
TMP3L8R 800 (2) 250-500 TMPAL30 1 lug per kit, 1 lug per phase Compression TMP3L12CLL1
for up to 4 conductors per phase
4 studs per phase, double stack
TMPL12R 1200 (2) 250-500 TMPAL30 1 lug per kit, 1 lug per phase Compression TMP3L12CLL1
for up to 4 conductors per phase
4 studs per phase, double stack
TMP3L12R 1200 (2) 250-500 TMPAL30 1 lug per kit, 1 lug per phase Compression TMP3L12CLL1
for up to 4 conductors per phase
(4) 1/0-750 TMP3L16BLK 1 kit per device, 4 connector assy's
TMPL16R 1600 Compression TMP3L16CLL1
or (8) 1/0-300 w/4 lugs each (16 total lugs), 1 assy/phase
(4) 1/0-750 TMP3L16BLK 1 kit per device, 4 connector assy's
TMP3L16R 1600 Compression TMP3L16CLL1
or (8) 1/0-300 w/4 lugs each (16 total lugs), 1 assy/phase

Rev. 11/13 www.geindustrial.com BuyLog Catalog 2-17


Data subject to change
without notice
Modular Metering Section 2
Meter Mod III
Main Pull Box Modules and Accessories
Single-Phase and Three-Phase

TMPU4R

Main Pull Box Single-Phase, Three-Wire 120/240 Vac


End mounting. Lugs only included; cross bus not included.
Main Main Wire Size Main Wire Size Stud sets
Ampere IC Rating1 AWG/kcmil AWG/kcmil per Phase Compression Lug Product
Wire Entry Rating (Max) Cu/Al - Phase Cu/Al - Neutral and Neutral Landing Kit Number
Bottom/Top 400 100 kAIC (1) 1/0-750 or (1) 1/0-750 or 1 Included TMPU4R
(2) 1/0 -300 (Load) (2) 1/0 -300 (Load)
Bottom/Top 800 100 kAIC (2) 1/0-750 or (2) 1/0-750 or 2 Included TMPU8R
(4) 1/0 -300 (Load) (4) 1/0 -300 (Load)
Bottom/Top 1200 100 kAIC (4) 2-600 (Load) (4) 2-600 (Load) 3 Included TMPU12R
1Limited to the lowest marked short circuit rating of the main and meter modules used.

Main Pull Box Three-Phase, Four-Wire / Single-Phase, Three-Wire 120/240 Vac, 208Y/120 Vac, 240/120 Vac
End or center mounting. Lugs only included; cross bus not included.
Main Main Wire Size Main Wire Size Stud sets
Ampere IC Rating1 AWG/kcmil AWG/kcmil per Phase Compression Lug Product
Wire Entry Rating (Max) Cu/Al - Phase Cu/Al - NeutraL and Neutral Landing Kit Number
Bottom/Top 400 100 kAIC (1) 1/0-750 or (1) 1/0-750 or 1 Included TMP3U4R
(2) 1/0-300 (Load) (2) 1/0 -300 (Load)
Bottom/Top 800 100 kAIC (2) 1/0-750 or (2) 1/0-750 or 2 Included TMP3U8R
(4) 1/0-300 (Load) (4) 1/0-300 (Load)
Bottom/Top 1200 100 kAIC (4) 2-600 (Load) (4) 2-600 (Load) 3 Included TMP3U12R
1Limited to the lowest marked short circuit rating of the main and meter modules used.

Class T Fuses Factory Installed Lug Kit


Phase Neutral
Product
Main Amp Wire GE Lug Kit
Frame Size Ampere Rating Number
Pull Box Rating Description Size Product No. Lugs Per Kit
400 250 TFUSE250
TMPU4R 400 (1) 1/0-750 or (1) 1/0-750 or 1 lug per phase,
400 300 TFUSE300
(2) 1/0-300 (Load) (2) 1/0-300 (Load) TMPL750 3 lugs per kit
400 350 TFUSE350
TMP3U4R 400 (1) 1/0-750 or (1) 1/0-750 or 1 lug per phase,
400 400 TFUSE400
(2) 1/0-300 (Load) (2) 1/0-300 (Load) TMPL750 3 lugs per kit
600 500 TFUSE500
TMPU8R 800 (2) 1/0-750 or (2) 1/0-750 or 2 lugs per phase,
600 600 TFUSE600
(4) 1/0-300 (Load) (4) 1/0-300 (Load) TMPL750 3 lugs per kit
800 800 TFUSE800
TMP3U8R 800 (2) 1/0-750 or (2) 1/0-750 or 2 lugs per phase,
1200 1200 A3T1200
(4) 1/0-300 (Load) (4) 1/0-300 (Load) TMPL750 3 lugs per kit
TMPU12R 1200 (4) 2-600 (load) (4) 2-600 (load)
TMP3U12R 1200 (4) 2-600 (load) (4) 2-600 (load)

Lug and Neutral Kits


Product
Description Number
Accepts (4) 3/0-750 mcm for use with 400 and 600 amp switch TMPL40
(2) 250-500 mcm for use with 800 and 1200 amp main lug TMPAL30
Neutral Kit, for 1600A and 2000A Main Breaker TMBP2000N
Lug Kit, for 1200A Main Lug device (3) 1/0-750 or (6) 1/0-300 TMP3L12BLK
Lug Kit, for 1600A main lug device, (8) 1/0-300 or (4)2-750 mcm TMP3L16BLK
Crimp Lug Pad Kit(4) 1600A Main Lug TMP3L16CLL3
Alternate Lug Kit for 1400A and 1600A Main Breaker TMPL2000RD
3Single lug but can put up to 2 lugs per phase on main.

2-18 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Modular Metering Section 2
Meter Mod III
Meter Stack Modules
Single-Phase
Plus Accessories

TMP8512R TMPR8220R

Product Features Product Features


UL listed UL listed
800 amp, 4-wire cross bus (aluminum), except where noted below. 1200 amp, 4-wire cross bus (aluminum)
Ring-type and Ringless Sockets Ring-type and Ringless Sockets
Front Accessible Field Phase Balancing by Meter Module Front Accessible Field Phase Balancing by Meter Module
(1) 14-4 Equipment Ground per Socket, Factory Installed (1) 14-4 Equipment Ground per Socket, Factory Installed

Ring Type Socket - 800A Horizontal Bussing Ring-Type Socket - 1200A Horizontal Bussing
No. of Standard MEG No. of Standard MEG
Socket Amps Sockets Product Number Product Number2 Socket Amps Sockets Product Number Product Number2
125A 2 TMP8212R TMP8212RF 125A 2 TMP12212R TMP12212RF
125A 3 TMP8312R TMP8312RF 125A 3 TMP12312R TMP12312RF
125A 4 TMP8412R TMP8412RF 125A 4 TMP12412R TMP12412RF
125A 5 TMP8512R TMP8512RF 125A 5 TMP12512R TMP12512RF
125A 6 TMP8612R TMP8612RF 125A 6 TMP12612R TMP12612RF
200A 2 TMP8220R Use TMP8320RF 200A 2 TMP12220R TMP12220RF
200A 3 TMP8320R TMP8320RF 200A 3 TMP12320R TMP12320RF
200A 4 TMP8420R TMP8420RF 200A 4 TMP12420R TMP12420RF
200A 5 TMP8520R Use two smaller sections 200A 5 TMP12520R TMP12520RF
200A 5 TMP8520RBUS3 Use two smaller sections 200A 5 TMP12520RBUS3 Use TMP12520RF

One snap-type, aluminum sealing ring (TSR5) per socket included.

Ringless Type Socket - 800A Horizontal Bussing Ringless Type Socket - 1200A Horizontal Bussing
(Includes 5th Jaw Standard) (Includes 5th Jaw Standard)
Standard MEG MEG & Standard MEG MEG &
Socket No. of Product Product Horned Bypass Horned Bypass
Socket No. of Product Product Horned Bypass Horned Bypass
Amps Sockets Number Number2 Product Number1 Product Number2
Amps Sockets Number Number2 Product Number1 Product Number2
TMPR12412RF+
125A 2 TMPR8212R TMPR8212RF TMPR8212RHB TMPR8212RHBF1 TMPR12412RF+
125A 2 TMPR12212R TMPR12212RHB (2) TMCB12B+
125A 3 TMPR8312R TMPR8312RF TMPR8312RHB TMPR8312RHBF1 (2) TMCB12B
(1) TMPBH20A
125A 4 TMPR8412R TMPR8412RF TMPR8412RHB TMPR8412RHBF1
TMPR12412RF+
Use TMPR8512RF+ TMPR12412RF+
125A 5 TMPR8512R TMPR8512RF TMPR8512RHB 125A 3 TMPR12312R TMPR12312RHB (1) TMCB12B+
TMBPH20A (1) TMCB12B
(1) TMPBH20A
Use TMPR8612RF+
125A 6 TMPR8612R TMPR8612RF TMPR8612RHB 125A 4 TMPR12412R TMPR12412RF TMPR12412RHB TMPR12412RHBF1
TMBPH20A
125A 5 TMPR12512R TMPR12512RF TMPR12512RHB TMPR12512RHBF1
Use TMPR8220RHB+
200A 2 TMPR8220R Use TMPR8320RF TMPR8220RHB TMPR12612RF+
TMBPH20A 125A 6 TMPR12612R TMPR12612RF TMPR12612RHB
TMBPH20A
Use TMPR8320RHB+
200A 3 TMPR8320R TMPR8320RF TMPR8320RHB TMPR12420RF+
TMBPH20A TMPR12420RF+
200A 2 TMPR12220R TMPR12220RHB (2) TMCB20B+
200A 4 TMPR8420R TMPR8420RF TMPR8420RHB TMPR8420RHBF1 (2) TMCB20B
(1) TMPBH20A
Use TMPR8520RHB+
200A 5 TMPR8520R TMPR8520RF TMPR8520RHB TMPR12420RF+
TMBPH20A TMPR12420RF+
200A 3 TMPR12320R TMPR12320RHB (1) TMCB20B+
Use TMPR8520RF+ (1) TMCB20B
200A 5 TMPR8520RBUS3 Use TMPR8520RF TMPR8520RHBBUS3 (1) TMPBH20A
TMBPH20A
200A 4 TMPR12420R TMPR12420RF TMPR12420RHB TMPR12420RHBF1
1Includes horn by-pass. TMPR12520RF+
2F units have an additional cotter pin that has been added to the meter socket 200A 5 TMPR12520R TMPR12520RF TMPR12520RHB
TMBPH20A
assembly that will keep the meter socket from detaching from the base. This Use TMPR12520RF+
change meets the new MEG requirements. 200A 5 TMPR12520RBUS3 Use TMPR12520RF TMPR12520RHBBUS3
TMBPH20A
3Parts with BUS on the end have the horizontal bussing centerline on the 3rd meter
rather than 2nd meter, making the unit shorter from the centerline for applications
where height of top meter may be an issue. Ring Type Socket Factory Phase Balanced (w/Copper Bus)
No. of Product
Socket Amps Sockets Number
125A 2 TMP8212RAB
125A 2 TMP8212RAC
125A 2 TMP8212RBC
125A 3 TMP8312RAB
125A 3 TMP8312RAC
125A 3 TMP8312RBC
125A 4 TMP8412RAB
125A 4 TMP8412RAC
125A 4 TMP8412RBC

Rev. 11/13 www.geindustrial.com BuyLog Catalog 2-19


Data subject to change
without notice
Page Updated 09 / 2016

Modular Metering Section 2


Meter Mod III
Meter Stack Modules
Single-Phase
Plus Accessories

Tenant Main Circuit Breakers 10,000 AIC


Wire Size Product
Socket Amps Ampere Rating Load Lugs Number
125 60 (1) #8-#3 CU; #8-#3 AL THQL2160
125 70 (1) #6-1/0 CU; #4-#1/0 AL THQL2170
125 80 (1) #6-1/0 CU; #4-#1/0 AL THQL2180
125 90 (1) #6-1/0 CU; #4-#1/0 AL THQL2190
125 100 (1) #6-1/0 CU; #4-#1/0 AL THQL21100
125 110 (1) #6-1/0 CU; #4-#1/0 AL THQL21110
125 125 (1) #2-2/0 CU; #2-2/0 AL THQL21125
125 125 TMQL21125SF1
200 100 (1) #1-300 CU; #1-300 AL TQD22100
200 125 (1) #1-300 CU; #1-300 AL TQD22125
200 150 (1) #1-300 CU; #1-300 AL TQD22150
200 175 (1) #1-300 CU; #1-300 AL TQD22175
200 200 (1) #1-300 CU; #1-300 AL TQD22200

Tenant Main Circuit Breakers 22,000 AIC


Wire Size Product
Socket Amps Ampere Rating Load Lugs Number
125 60 (1) #8-3 CU; #8-2 AL THHQL2160
125 70 (1) #6-1/0 CU; (1) #4 1/0 THHQL2170
125 80 (1) #6-1/0 CU; #4-1/0 AL THHQL2180
125 90 (1) #6-1/0 CU; #4-1/0 AL THHQL2190
125 100 (1) #6-1/0 CU; #4-1/0 AL THHQL21100
125 110 THHQL21110
125 125 (1) #2-2/0 CU; # 2-2/ AL THHQL21125
200 100 (1) #1-300 CU; #1-300 AL THQD22100
200 125 (1) #1-300 CU; #1-300 AL THQD22125
200 150 (1) #1-300 CU; #1-300 AL THQD22150
200 175 (1) #1-300 CU; #1-300 AL THQD22175
200 200 (1) #1-300 CU; #1-300 AL THQD22200

Tenant Main Circuit Breakers 42,000 AIC


Wire Size Product
Socket Amps Ampere Rating Load Lugs Number
125 60 (1) #10-1/0 CU; #10-1/0 AL TMQL2160
125 70 (1) #10-1/0 CU; #10-1/0 AL TMQL2170
125 80 (1) #10-1/0 CU; #10-1/0 AL TMQL2180
125 90 (1) #10-1/0 CU; #10-1/0 AL TMQL2190
125 100 (1) #10-1/0 CU; #10-1/0 AL TMQL21100
125 125 (1) #10-1/0 CU; #10-1/0 AL TMQL21125

Tenant Main Circuit Breakers 100,000 AIC


Wire Size Product
Socket Amps Ampere Rating Load Lugs Number
200 60 (1) #6-1/0 CU; #6-1/0 AL TMQD22060
200 70 (1) #6-1/0 CU; #6-1/0 AL TMQD22070
200 80 (1) #6-1/0 CU; #6-1/0 AL TMQD22080
200 90 (1) #6-1/0 CU; #6-1/0 AL TMQD22090
200 100 (1) #6-4/0 CU; #6-4/0 AL TMQD22100
200 125 (1) #6-4/0 CU; #6-4/0 AL TMQD22125
200 150 (1) #6-4/0 CU; #6-4/0 AL TMQD22150
200 175 (1) #6-4/0 CU; #6-4/0 AL TMQD22175
200 200 (1) #6-4/0 CU; #6-4/0 AL TMQD22200
1Sub-feed lug, no overcurrent protection.

2-20 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Modular Metering Section 2
Meter Mod III
Meter Stack Modules
Single-Phase
Plus Accessories

Accessories - Field Installed


Product
Description Number
By-pass Kits
Manual Slider-Type (Ring Type Only)
-125 amp top socket for 2, 3, 5 and 6 gang TMBPM12TA2
-125 amp for all other sockets TMBPM12A2
-200 amp for all sockets TMBPM20A2
Jumper Straps Type
(use with TMCA) TMBPJ201,3
Cover Including Jumper Strap Type-fits all TMBPJ20 TMBPM12TA
(Ring Type Only) TMBPC201
Horn-Type-fits all (Ringless Only) TMBPH20A3
Fifth Jaw Kits
-Bused; 3, 6, or 9 o'clock mounting: TM5JA
Order two for fifth and sixth jaw. Not suitable for 2-gang ring type
-Isolated; 3 or 9 o'clock mounting TM5JUA
Sealing Rings
-Screw-Type, Aluminum TSR1
-Snap Type, Stainless Steel TSR3
-Screw and Lock-Type, Aluminum TSR4
-Snap-Type, Aluminum (Standard) TSR5
Steel Meter Socket Covers
Blank (fits bottom position only) TSR1 TSR3
-125 Amp TMCB12B
-200 Amp TMCB20B
Ringless (Field -converts ring-type to ringless)
-125 amp top socket for 2 and 3 gang TMCR12T
-125 amp for all other sockets TMCR12
-200 amp for all sockets TMCR20
Lexan Meter socket Cover Plate (without tabs) TMCA
Lexan Meter Socket Cover Plate TMCP
Equipment Ground Bar, (6) 6-2/0 TMEG
Individual Meter Socket Barrier Kit (includes 6) TMBR
Mounting Z-Rail, 4-foot TMZR
Spacer 4-inch, TMPS12
4 cross bus rated 1200A TMCB12B TMCR12
Elbow 16 inch x 16 inch, TMPE124
4 cross bus rated 1200A
Elbow 12 inch x 12 inch, TMPE12A4
4 cross bus rated 1200A
Main Module Door Barrier Kit, Bottom TMP3FBB
Closure Kit Feed Main
Anti-Inversion Clip TMIC
Endwall TM234BEW200
Endwall TM56BEW200
TQD Mounting Kit TQD Breaker Mounting Kit - This is a replacement TMTQD3
part. Units come with this part factory installed.
1Not UL Listed.
TMCR12T TMCP
2200 amps continuous.
3100 amps continuous.
4Indoor Type 1.

TMZR

TMBR

Rev. 11/13 www.geindustrial.com BuyLog Catalog 2-21


Data subject to change
without notice
Page Updated 09 / 2016

Modular Metering Section 2


Meter Mod III
Meter Stack Modules
Single-Phase
Plus Accessories

Product Features
Single-Phase/Three-Wire, 120/240 Vac or Three-Phase,
Four-Wire, Horizontal Bus, 208Y/120 Vac System Voltage
UL listed
1200 amp, 4-wire cross bus (aluminum)
Front Accessible Field Phase Balancing by Meter Socket
(1) 14-2 Equipment Ground per Socket, Factory Installed
Only 225A and 400 Ringless Type meter stacks, contain lever
bypass. 125A and 200A meter sockets do not contain lever
bypass
Ringless Type Socket w/ Lever Bypass
TMPR12122R
Product
Socket Amps No. of Sockets Number
225A 1 TMPR12122R1,5
225A 2 TMPR12222R1,5
Tenant Main Circuit Breakers 100,000 AIC
225A 3 TMPR12322R1,5 Wire Size Product
225A 4 TMPR12422R1,5 Socket Amps Ampere Rating Load Lugs Number
400A 1 TMPR12140RB1,2,9
400A 2 TMPR12240RB1,3,9 200 60 (1) #6-1/0 CU; # 6-1/0 AL TMQD22060
400A 1 TMPK12140RB1 200 70 (1) #6-1/0 CU; # 6-1/0 AL TMQD22070
400A 1 TMPK12140RBA1 200 80 (1) #6-1/0 CU; # 6-1/0 AL TMQD22080
200 90 (1) #6-1/0 CU; # 6-1/0 AL TMQD22090
Ring Type Socket 200 100 (1) #6-4/0 CU; #6-4/0 AL TMQD22100
200 125 (1) #6-4/0 CU; #6-4/0 AL TMQD22125
Product 200 150 (1) #6-4/0 CU; #6-4/0 AL TMQD22150
Socket Amps No. of Sockets Number 200 175 (1) #6-4/0 CU; #6-4/0 AL TMQD22175
225A 1 TMP8120RTAB4,5 200 200 (1) #6-4/0 CU; #6-4/0 AL TMQD22200
225A 1 TMP8120RTBC4,5
225A 1 TMP8120RTAC4,5
225A 2 TMP112220RTAB4,5 Accessories Field Installed
225A 2 TMP112220RTAC4,5 Product
225A 2 TMP112220RTBC4,5 Type Description Number
225A 3 TMP112320RTAB4,5
225A 3 TMP112320RTAC4,5 TEB Breaker TMTEB
225A 3 TMP112320RTBC4,5 Mounting Kit
Barrel Lock Bracket TMBL6
One snap-type, aluminum sealing ring (TSR5) per socket included. and Guard Kit
Bypass Kit Totalizing Jumper Type TMBPT3206,7
Tenant Main Circuit Breakers 10,000 AIC Blank Meter
Socket Cover Fits all positions TMCB322A
Wire Size Product Individual Meter TMBR3
Socket Amps Ampere Rating Load Lugs Number
Socket Barrier Kit (Includes 6)
225 15 (1) #14-3 CU; #12-1 AL TEB122015 Insulator for Lever TMHN
225 20 (1) #14-3 CU; #12-1 AL TEB122020 By-pass Handle
225 25 (1) #14-3 CU; #12-1 AL TEB122025 Mounting Z Rail 4-foot TMZR
225 30 (1) #14-3 CU; #12-1 AL TEB122030 Spacer 4 inch, TMPS12
225 35 (1) #14-3 CU; #12-1 AL TEB122035 4 cross bus rated, 1200A
225 40 (1) #14-3 CU; #12-1 AL TEB122040
Elbow 16 inch x 16 inch, TMPE128
225 45 (1) #14-3 CU; #12-1 AL TEB122045
225 50 (1) #14-3 CU; #12-1 AL TEB122050 4 cross bus rated 1200A
225 60 (1) #14-3 CU; #12-1 AL TEB122060 Elbow 12 inch x 12 inch, TMPE12A8
225 70 (1) #14-3 CU; #12-1 AL TEB122070 4 cross bus rated 1200A
225 80 (1) #14-3 CU; #12-1 AL TEB122080 1Only 225A and 400A are lever bypass.
225 90 (1) #14-3 CU; #12-1 AL TEB122090 2One 400A tenant breaker included.
225 100 (1) #14-3 CU; #12-1 AL TEB122100
3Two 400A tenant breakers included.
225 125 (1) #1-300 CU; #1-300 AL TQD22125
225 150 (1) #1-300 CU; #1-300 AL TQD22150 4Meets EUSERC requirements. T- suffix signifies test bypass kit. Suffixes AB, BC, AC
225 175 (1) #1-300 CU; #1-300 AL TQD22175 reflect the factory-set phase balancing.
225 200 (1) #1-300 CU; #1-300 AL TQD22200 5Included factory-installed fifth jaw (TM5JA Bused).
6Not UL listed.
Tenant Main Circuit Breakers 22,000 AIC 7180 amps continuous.
8Indoor, Type 1.
Wire Size Product
9See Page 2-12 for alternate 400A Rating Plugs
Socket Amps Ampere Rating Load Lugs Number
200 100 (1) #1-300 CU; #1-300 AL THQD22100
200 125 (1) #1-300 CU; #1-300 AL THQD22125
200 150 (1) #1-300 CU; #1-300 AL THQD22150
200 175 (1) #1-300 CU; #1-300 AL THQD22175
200 200 (1) #1-300 CU; #1-300 AL THQD22200

2-22 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Modular Metering Section 2
Meter Mod III
Meter Stack Modules
Three-Phase
Plus Accessories

Product Features
Three-Phase/Four-Wire, 240-120 Vac; Three-Phase/Four-Wire,
208Y/120 Vac
UL listed
1200 amp, 4-wire cross bus (aluminum)
Front Accessible Field Phase Balancing by Meter Socket
(1) 14-2 Equipment Ground per Socket, Factory Installed
Swingaway Mounting Feet Factory Installed
Only 225A and 400A sockets, Ringless Type, contain lever
bypass. 125A + 200A meter sockets do not contain lever bypass.
TMPR312140RB

Ringless Type Socket w/Lever Bypass. All units are 7-terminal Tenant Main Circuit Breakers 22,000 AIC
except TMPK. Wire Size Product
Socket Amps Ampere Rating Load Lugs Number
Product
Socket Amps No. of Sockets Number 225/400/200 100 (1) #1-300 CU; #1-300 AL THQD32100
225/400/200 125 (1) #1-300 CU;#1-300 AL THQD32125
225A 1 TMPR312122R8
225/400/200 150 (1) #1-300 CU; #1-300 AL THQD32150
225A 2 TMPR312222R8
225/400/200 175 (1) #1-300 CU; #1-300 AL THQD32175
225A 3 TMPR312322R8
225/400/200 200 (1) #1-300 CU; #1-300 AL THQD32200
225A 4 TMPR312422R8
225/400/200 225 Use TMQD
400A 1 TMPR312140TR1,8
400A 1 TMPR312140RB2,8
400A 2 TMPR312240RB3,8
Tenant Main Circuit Breakers 100,000 AIC
400A 1 TMPK312140RB Wire Size Product
400A 1 TMPK312140RBA Socket Amps Ampere Rating Load Lugs Number
225/400/200 60 (1) #6-1/0 CU; #6-1/0 AL TMQD32060
Ring Type Socket 7-terminal units 225/400/200 70 (1) #6-1/0 CU; #6-1/0 AL TMQD32070
Product 225/400/200 80 (1) #6-1/0 CU; #6-1/0 AL TMQD32080
Socket Amps No. of Sockets Number 225/400/200 90 (1) #6-1/0 CU; #6-1/0 AL TMQD32090
225/400/200 100 (1) #6-4/0 CU; #6-4/0 AL TMQD32100
200A 1 TMP38120RT4,8
225/400/200 125 (1) #6-4/0 CU; #6-4/0 AL TMQD32125
200 A 2 TMP312220RT4,8
225/400/200 150 (1) #6-4/0 CU; #6-4/0 AL TMQD32150
200A 3 TMP312320RT4,8
225/400/200 175 (1) #1/0-300 CU; 1/0-300 AL TMQD32175
225/400/200 200 (1) #1/0-300 CU; 1/0-300 AL TMQD32200
Tenant Main Circuit Breakers 10,000 AIC 225/400/200 225 (1) #1/0-300 CU; 1/0-300 AL TMQD32225
Wire Size Product
Socket Amps Ampere Rating Load Lugs Number Accessories Field Installed
225/400/200 15 (1) #14-3 CU; #12-1 AL TEB132015 Product
225/400/200 20 (1) #14-3 CU; #12-1 AL TEB132020 Type Description Number
225/400/200 25 (1) #14-3 CU; #12-1 AL TEB132025
TEB Breaker TMTEB
225/400/200 39 (1) #14-3 CU; #12-1 AL TEB132030
Mounting Kit
225/400/200 35 (1) #14-3 CU; #12-1 AL TEB132035
Barrel Lock Bracket TMBL5
225/400/200 40 (1) #14-3 CU; #12-1 AL TEB132040
and Guard Kit
225/400/200 45 (1) #14-3 CU; #12-1 AL TEB132045
Bypass Kit Totalizing Jumper Type TMBPT3205,6
225/400/200 50 (1) #14-3 CU; #12-1 AL TEB132050
Replacement TMPJ315
225/400/200 60 (1) #14-3 CU; #12-1 AL TEB132060
Phase Balancing
225/400/200 70 (1) #6-2/0 CU; #4-2/0 AL TEB132070
Jumper Kit
225/400/200 80 (1) #6-2/0 CU; #4-2/0 AL TEB132080
Blank Meter
225/400/200 90 (1) #6-2/0 CU; #4-2/0 AL TEB132090
Socket Cover Fits all positions TMCB322A
225/400/200 100 (1) #6-2/0 CU; #4-2/0 AL TEB132100
Individual Meter TMBR3
225/400/200 125 (1) #1-300 CU; #1-300 AL TQD32125
Socket Barrier Kit (Includes 6)
225/400/200 150 (1) #1-300 CU; #1-300 AL TQD32150
Insulator for Lever TMHN
225/400/200 175 (1) #1-300 CU; #1-300 AL TQD32175
By-pass Handle
225/400/200 200 (1) #1-300 CU; #1-300 AL TQD32200
Mounting Z Rail 4-foot TMZR
225/400/200 225 Use TMQD
Spacer 4 inch, TMPS12
4 cross bus rated, 1200A
Elbow 16 inch x 16 inch, TMPE127
4 cross bus rated 1200A
Elbow 12 inch x 12 inch, TMPE12A7
4 cross bus rated 1200A
1Requires two tenant main breakers, 400 amp maximum sum of branch ratings.
Cannot be used to serve a single 400A load.
2400 Amp tenant breaker included, 65 kAIC.
3Two 400 Amp tenant breakers included.
4Meets EUSERC requirements. T suffix indicates EUSERC test bypass kit included.
5Not UL listed.
6180 amps continuous.
7Indoor, Type 1, for inside corners only.
8These product numbers are shipped from the factory as 7-jaw units (7-terminal).

Rev. 11/13 www.geindustrial.com BuyLog Catalog 2-23


Data subject to change
without notice
Modular Metering Section 2
Phase Balancing
125A STACKS 200A STACKS
"Barrel" Shaped "Barrel" Shaped
Phase Connector Phase Connector

N N N N
All three-phase meter stack modules come fac-
tory connected to phase A and B, per Figure A. A A
A A A A
When connected to a 208Y/120 Vac 3-phase,
4-wire system, field phase balancing of two out
of every three stacks is required. One of every B B B B

three stacks should be phased AC, per Figure B,


and one of every three stacks should be phased C C C C
B B
CB, per Figure C. "Z" Shaped
Phase Connector
Examples: FACTORY 125A A-B PHASING "Z" Shaped
9 Total Positionsuse (3) 3-position stacks and Phase Connector
phase one per Figure B (A-C phasing) and one FACTORY 200A A-B PHASING
per Figure C (C-B) phasing. Figure A
16 Total Positionsuse (2) 5-position and (2)
3-position stacks. Phase balance (1) 5-position
per figure B (A-C phasing) and (1) 5-position "Barrel" Shaped "Barrel" Shaped
Phase Connector Phase Connector
per Figure C (C-B phasing).
19 Total Positionswhere 4 position maximum N N N N
height is allowed by utility, use (1) 4-position A A
and (5) 3-position stacks. Phase balance (2) A A A A
3-position stacks per Figure B (A-C phasing) and
(2) e-position stacks per Figure C (C-B) phasing. B B B B

C C C C
C
"Barrel" Shaped
Phase Connector C
FIELD 125A A-C PHASING "Z" Shaped
Remove "Z" Phase Connector from "B" Phase Phase Connector
Horizontal Bus FACTORY 200A A-C PHASING
Replace with "Barrel" Phase Connector supplied
Remove "Z" Phase Connector from "B" Phase
with meter stack and attach to "C" Phase Bus
Horizontal Bus
as shown.
Reattached at "C" Phase Horizontal Bus as Shown.
Torque to 60 lb-in (6.78 N-M)
Torque to 60 lb-in (6.78 N-M)
Retain "Z" Phase Connector for future use.
"Z" Shaped
Phase
Connector
Figure B

N N N N

A A A A
"Barrel" Shaped
Phase
Connector B B B B

C C C C C
Z Shaped and Barrel Shaped Phase B C B
Connectors
"Barrel" Shaped "Z" Shaped
Phase Connector Phase Connector
FIELD 125A C-B PHASING "Barrel" Shaped "Z" Shaped
Phase Connector Phase Connector
Remove "Barrel" Phase Connector from "A" Phase
Horizontal Bus FACTORY 200A C-B PHASING
Reattached at "C" Phase Horizontal Bus as shown. Remove "Barrel" Phase Connector from "A" Phase
Torque to 60 lb-in (6.78 N-M) Horizontal Bus
Reattached at "C" Phase Horizontal Bus as shown.
Torque to 60 lb-in (6.78 N-M)

Figure C

2-24 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Modular Metering Section 2
Applications Where Center-Feeding Main Module is Required

SUITABLE FOR CENTER-FEED APPLICATIONS ONLY*


*Horizontal bus is rated 1200 amps maximum. The load on the
horizontal bus may not exceed 1200 amps in either direction from
the point of connection of the main circuit breaker. Overall load is
limited to the rating of the main circuit breaker.

For applications where the main module ampere rating is greater than that of the meter stack horizontal bus, the main
module must be placed in the middle of the lineup (Figure A). The engineer of record must provide calculations on the
plans to show that the horizontal bussing will not be overloaded on either side. This situation, called Center-Feeding, can
happen in either 800A or 1200A horizontal bus meter stack applications, depending on the main ampere rating. Refer to
chart below for amperage and bus information. NOTE: Figure B shows the incorrect configurations.

Does the Application Require Electrician to Center-Feed the


Main Module?
Amps of Main Breaker, 800A 1200A
Lug or Switch Horizontal Bus Horizontal Bus
400A 800A No No
1000A Yes No
1200A Yes No
1400A Yes Yes
1600A Yes Yes
2000A Yes Yes

Main Main Main

Correct Incorrect Incorrect


This configuration is centered and will This configuration will overload the This configuration will overload the
balance the load between left and left-side horizontal bus that leaves the right-side horizontal bus that leaves
right-side horizontal bus leaving the main section the main section
main section

Figure A Figure B

Rev. 11/13 www.geindustrial.com BuyLog Catalog 2-25


Data subject to change
without notice
Modular Metering Section 2
Mini Mod III
Enclosure Knockout Dimensions

Dimensions
Product Width Height Depth Section A Section B
Description Number Figure No.1 (in inches) (in inches) (in inches) (in inches) (in inches)
Mini Mod, 1P3W, 200A MLO, (2) 125A Ring sockets TMM2212R, TMM2212RF 1 11.88 34.56 7.56 18.31 9.00
Mini Mod, 1P3W, 200A MLO, (2) 125A Ringless sockets TMMR2212R, TMMR2212RF, TMMR2212RHB 1 11.88 34.56 7.56 18.31 9.00
Mini Mod, 1P3W, 400A MLO, (3) 125A Ring sockets TMM4312R, TMM4312RF 3 24.25 48.31 7.00 21.56 9.00
Mini Mod, 1P3W, 400A MLO, (3) 125A Ringless sockets TMMR4312R, TMMR4312RF, TMMR4312RHB 3 24.25 48.31 7.00 21.56 9.00
Mini Mod, 1P3W, 400A MLO, (4) 125A Ring sockets TMM4412R, TMM4412RF 3 24.25 48.31 7.00 12.56 9.00
Mini Mod, 1P3W, 400A MLO, (4) 125A Ringless sockets TMMR4412R, TMMR4412RF, TMMR4412RHB 3 24.25 48.31 7.00 12.56 9.00
Mini Mod, 1P3W, 600A MLO, (5) 125A Ring sockets TMM6512R, TMM6512RF 2 36.28 41.59 7.00 12.56 9.00
Mini Mod, 1P3W, 600A MLO, (5) 125A Ringless sockets TMMR6512R, TMMR6512RF, TMMR6512RHB 2 36.28 41.59 7.00 12.56 9.00
Mini Mod, 1P3W, 600A MLO, (6) 125A Ring sockets TMM6612R, TMM6612RF 2 36.28 41.59 7.00 12.56 9.00
Mini Mod, 1P3W, 600A MLO, (6) 125A Ringless sockets TMMR6612R, TMMR6612RF, TMMR6612RHB 2 36.28 41.59 7.00 12.56 9.00
Mini Mod, 1P3W, 400A MLO, (2) 200A Ring sockets TMM4220R 5 25.50 42.69 7.00 18.44 12.13
Mini Mod, 1P3W, 400A MLO, (2) 200A Ringless sockets TMMR4220R, TMMR4220RF, TMMR4220RHB 5 25.50 42.69 7.00 18.44 12.13
Mini Mod, 1P3W, 600A MLO, (3) 200A Ring sockets TMM6320R, TMM6320RF 5 25.50 64.56 7.00 30.56 12.13
Mini Mod, 1P3W, 600A MLO, (3) 200A Ringless sockets TMMR6320R, TMMR6320RF, TMMR6320RHB 5 25.50 64.56 7.00 30.56 12.13
Mini Mod, 1P3W, 600A MLO, (4) 200A Ring sockets TMM6420R, TMM6420RF 5 25.50 64.56 7.00 18.44 12.13
Mini Mod, 1P3W, 600A MLO, (4) 200A Ringless sockets TMMR6420R, TMMR6420RF, TMMR6420RHB 5 25.50 64.56 7.00 18.44 12.13
Mini Mod, 1P3W, 600A MLO, (5) 200A Ring sockets TMM6520R 4 38.75 52.44 7.00 18.44 12.13
Mini Mod, 1P3W, 600A MLO, (5) 200A Ringless sockets TMMR6520R, TMMR6520RF, TMMR6520RHB 4 38.75 52.44 7.00 18.44 12.13
Mini Mod, 1P3W, 600A MLO, (6) 200A Ring sockets TMM6620R 4 38.75 52.44 7.00 18.44 12.13
Mini Mod, 1P3W, 600A MLO, (6) 200A Ringless sockets TMMR6620R, TMM6620RF, TMMR6620RHB 4 38.75 52.44 7.00 18.44 12.13
1Figures 2, 3 and 5 have removable drip hood and open end wall.

Knockouts
Symbol A B C D E F G H I J K L
1 1
2 2
3
4
1 1 1 1
Conduit 114 114 114 114
Size 112 112 112 112 112 112
in 2 2 2 2 2 2
Inches 212 212 212 212 212
3 3 3 3
312 312 312
4 4 4
5

Figure 1 Figure 2

Figure 3 Figure 4 Figure 5

2-26 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Modular Metering Section 2
Meter Mod III
Enclosure Knockout Dimensions

Dimensions
Product Width Height Depth Section A Section B
Description Number Figure No.1 (in inches) (in inches) (in inches) (in inches) (in inches)

Meter Stack, 1P3W, (2) 125A Ring sockets, 800A horizontal bus TMP8212R, TMP8212RF3 1 12.26 41.60 6.62 21.61 9.00
TMPR8212R, TMPR8212RHB2, 1 12.26 41.60 6.62 21.61 9.00
Meter Stack, 1P3W, (2) 125A Ringless sockets, 800A horizontal bus
TMPR8212RF3, TMPR8212RHBF2,3
Meter Stack, 1P3W, (3) 125A Ring sockets, 800A horizontal bus TMP8312R, TMP8312RF3 1 12.26 41.60 6.62 21.61 9.00
TMPR8312R, TMPR8312RHB2 , 1 12.26 41.60 6.62 21.61 9.00
Meter Stack, 1P3W, (3) 125A Ringless sockets, 800A horizontal bus
TMPR8312RF3, TMPR8312RHBF2,3
Meter Stack, 1P3W, (4) 125A Ring sockets, 800A horizontal bus TMP8412R, TMP8412RF3 1 12.26 48.50 6.62 21.61 9.00
TMPR8412R, TMPR8412RHB2, 1 12.26 48.50 6.62 21.61 9.00
Meter Stack, 1P3W, (4) 125A Ringless sockets, 800A horizontal bus
TMPR8412RF3, TMPR8412RHBF2,3
Meter Stack, 1P3W, (5) 125A Ring sockets, 800A horizontal bus TMP8512R, TMP8512RF3 1 12.26 57.50 6.62 21.61 9.00
TMPR8512R, TMPR8512RHB2, 1 12.26 57.50 6.62 21.61 9.00
Meter Stack, 1P3W, (5) 125A Ringless sockets, 800A horizontal bus
TMPR8512RF3
Meter Stack, 1P3W, (6) 125A Ring sockets, 800A horizontal bus TMP8612R, TMP8612RF3 1 12.26 66.50 6.62 21.61 9.00
TMPR8612R, TMPR8612RHB2, 1 12.26 66.50 6.62 21.61 9.00
Meter Stack, 1P3W, (6) 125A Ringless sockets, 800A horizontal bus
TMPR8612RF3
Meter Stack, 1P3W, (2) 125A Ring sockets, 800A horizontal bus TMP8220R 2 13.38 52.36 6.62 30.55 12.13
TMPR8220R, TMPR8220RHB2, 2 13.38 52.36 6.62 30.55 12.13
Meter Stack, 1P3W, (2) 125A Ringless sockets, 800A horizontal bus
TMPR8220RF3
Meter Stack, 1P3W, (3) 125A Ring sockets, 800A horizontal bus TMP8320R, TMP8320RF3 2 13.38 52.36 6.62 18.42 12.13
TMPR8320R, TMPR8320RHB2, 2 13.38 52.36 6.62 18.42 12.13
Meter Stack, 1P3W, (3) 125A Ringless sockets, 800A horizontal bus
TMPR8320RF3
Meter Stack, 1P3W, (4) 125A Ring sockets, 800A horizontal bus TMP8420R, TMP8420RF3 2 13.38 64.51 6.62 18.42 12.13
TMPR8420R, TMPR8420RHB2, 2 13.38 64.51 6.62 18.42 12.13
Meter Stack, 1P3W, (4) 125A Ringless sockets, 800A horizontal bus
TMPR8420RF3, TMPR8420RHBF2,3
Meter Stack, 1P3W, (5) 125A Ring sockets, 800A horizontal bus TMP8520R, TM8520RBUS4 2 13.38 74.96 6.62 16.76 12.13
TMPR8520R, TMPR8520RHB2,
Meter Stack, 1P3W, (5) 125A Ringless sockets, 800A horizontal bus TMPR8520RF3, TMPR8520RBUS4 2 13.38 74.96 6.62 16.76 12.13
TMPR8520RHBBUS2,4
Meter Stack, 1P3W, (2) 125A Ring sockets, 1200A horizontal bus TMP12212R, TMP12212RF3 1 12.26 41.60 6.62 21.61 9.00
TMPR12212R, TMPR12212RHB2,
Meter Stack, 1P3W, (2) 125A Ringless sockets, 1200A horizontal bus TMPR12412RF + (2) TMCB12B3, 1 12.26 41.60 6.62 21.61 9.00
TMPR12212RHBF2,3
Meter Stack, 1P3W, (3) 125A Ring sockets, 1200A horizontal bus TMP12312R, TMP12312RF3 1 12.26 41.60 6.62 12.61 9.00
TMPR12312R, TMPR12312RHB2,
Meter Stack, 1P3W, (3) 125A Ringless sockets, 1200A horizontal bus TMPR12412RF + (1) TMCB12B3, 1 12.26 41.60 6.62 12.61 9.00
TMPR12312RHBF2,3
Meter Stack, 1P3W, (4) 125A Ring sockets, 1200A horizontal bus TMP12412R, TMP12412RF3 1 12.26 48.50 6.62 12.61 9.00
TMPR12412R, TMPR12412RHB2 1 12.26 48.50 6.62 12.61 9.00
Meter Stack, 1P3W, (4) 125A Ringless sockets, 1200A horizontal bus
TMPR12412RF3, TMPR12412RHBF2,3
Meter Stack, 1P3W, (5) 125A Ring sockets, 1200A horizontal bus TMP12512R, TMP12512RF3 1 12.26 57.50 6.62 12.61 9.00
TMPR12512R, TMPR12512RHB2, 1 12.26 57.50 6.62 12.61 9.00
Meter Stack, 1P3W, (5) 125A Ringless sockets, 1200A horizontal bus
TMPR12512RF3
Meter Stack, 1P3W, (6) 125A Ring sockets, 1200A horizontal bus TMP12612R, TMP12612RF3 1 12.26 66.50 6.62 12.61 9.00
TMPR12612R, TMPR12612RHB2, 1 12.26 66.50 6.62 30.55 9.00
Meter Stack, 1P3W, (4) 125A Ringless sockets, 1200A horizontal bus
TMPR12612RF3
Meter Stack, 1P3W, (2) 200A Ring sockets, 1200A horizontal bus TMP12220R 2 13.38 52.36 6.62 30.55 12.13
TMPR12220R, TMPR12220RHB2, 2 13.38 52.36 6.62 18.42 12.13
Meter Stack, 1P3W, (2) 200A Ringless sockets, 1200A horizontal bus
TMPR12420RF + (2) TMCB20B3
Meter Stack, 1P3W, (3) 200A Ring sockets, 1200A horizontal bus TMP12320R, TMP12320RF3 2 13.38 52.36 6.62 18.42 12.13
TMPR12320R, TMPR12320RHB2, 2 13.38 52.36 6.62 18.42 12.13
Meter Stack, 1P3W, (3) 200A Ringless sockets, 1200A horizontal bus
TMPR12420RF + (1) TMCB20B3
Meter Stack, 1P3W, (4) 200A Ring sockets, 1200A horizontal bus TMP12420R, TMP12420RF3 2 13.38 64.51 6.62 18.42 12.13
TMPR12420R, TMPR12420RHB2, 2 13.38 64.51 6.62 18.42 12.13
Meter Stack, 1P3W, (4) 200A Ringless sockets, 1200A horizontal bus
TMPR12420RF3, TMPR12420RHBF 2,3
Meter Stack, 1P3W, (5) 200A Ring sockets, 1200A horizontal bus TMP12520R, TM12520RBUS4 2 13.38 74.96 6.62 16.76 12.13
TMPR12520R, TMPR12520RHB2,
Meter Stack, 1P3W, (5) 200A Ringless sockets,1200A horizontal bus TMPR12520RF3, TMPR12520RBUS4, 2 13.38 74.96 6.62 16.76 12.13
TMPR12520RHBBUS2,4
Single-Phase, Three-Wire 225 A TMPR12122R 3 18 25.375 8.75 13
Single-Phase, Three-Wire 225 A TMPR12222R 3 18 52.625 8.75 27 14
Single-Phase, Three-Wire 225 A TMPR12322R 3 18 52.625 8.75 13 14
Single-Phase, Three-Wire 225 A TMPR12422R 3 18 66.625 8.75 13 14
Single-Phase, Three-Wire 225 A TMP8120RTAB 12 21.375 25 8.75
Single-Phase, Three-Wire 225 A TMP8120RTAC 12 21.375 25 8.75
1Figures referenced are on pages 2-29 and 2-30. Figures 1 through 8 have a removable top drip hood. Figure 4 has a removable top drip hood and open end wall.
2Includes horn by-pass.
3F units have an additional cotter pin that has been added to the meter socket assembly that will keep the meter socket from detaching from the base.
This change meets the new MEG requirements and should not be used outside of the state of Florida.
4Parts with BUS on the end have the horizontal bussing centerline on the 3rd meter rather than 2nd meter, making the unit shorter from the centerline for
applications where height of top meter may be an issue.

This table continued on next page.

Rev. 11/13 www.geindustrial.com BuyLog Catalog 2-27


Data subject to change
without notice
Modular Metering Section 2
Meter Mod III
Enclosure Knockout Dimensions

Dimensions
Product Width Height Depth Section A Section B
Description Number Figure No.1 (in inches) (in inches) (in inches) (in inches) (in inches)
Single-Phase, Three-Wire 225 A TMP8120RTBC 12 21.375 25 8.75
Single-Phase, Three-Wire 400 A TMPR12140RB 3 18 52.625 8.75 27
Three-Phase, Four-Wire 225 A TMPR312122R 3 18 25.375 8.75 13
Three-Phase, Four-Wire 400 A TMPR312140TR 3 18 52.625 8.75 41
Three-Phase, Four-Wire 225 A TMPR312222R 3 18 52.625 8.75 27 14
Three-Phase, Four-Wire 225 A TMPR312322R 3 18 52.625 8.75 13 14
Three-Phase, Four-Wire 225 A TMPR312422R 3 19 66.625 8.75 13 14
Three-Phase, Four-Wire 200 A TMP312220RT 3 21.38 43.00 8.75 27 14
Three-Phase, Four-Wire 200 A TMP312320RT 3 21.38 62.44 8.75 13 14
Three-Phase, Four-Wire 400 A TMPR312140RB 3 18 52.625 8.75 27
Main Breaker Modules TMPSB4R 4 20 47.625 11.75
Main Breaker Modules TMP3SB4R 4 20 47.625 11.75
Main Breaker Modules TMPSB6R 4 20 47.625 11.75
Main Breaker Modules TMP3SB6R 4 20 47.625 11.75
Main Breaker Modules TMPSB8R 4 20 47.625 11.75
Main Breaker Modules TMP3SB8R 4 20 47.625 11.75
Main Breaker Modules TMPSB10R 4 20 47.625 11.75
Main Breaker Modules TMP3SB10R 4 20 47.625 11.75
Main Breaker Modules TMPSB12R 4 20 47.625 11.75
Main Breaker Modules TMP3SB12R 4 20 47.625 11.75
Main Breaker Modules TMPSHB4R 4 20 47.625 11.75
Main Breaker Modules TMP3SHB4R 4 20 47.625 11.75
Main Breaker Modules TMPSHB6R 4 20 47.625 11.75
Main Breaker Modules TMP3SHB6R 4 20 47.625 11.75
Main Switch Modules TMPFT4R 4 20 47.625 11.75
Main Switch Modules TMP3FT4R 4 20 47.625 11.75
Main Switch Modules TMPFT6R 4 20 47.625 11.75
Main Switch Modules TMP3FT6R 4 20 47.625 11.75
Main Switch Modules TMPFT8R 4 20 47.625 11.75
Main Switch Modules TMP3FT8R 4 20 47.625 11.75
Main Switch Modules TMPFB4R 4 20 66.5 6.625
Main Switch Modules TMP3FB4R 4 20 66.5 6.625
Main Switch Modules TMPFB6R 4 20 66.5 6.625
Main Switch Modules TMP3FB6R 4 20 66.5 6.625
Main Switch Modules TMPFB8R 4 20 66.5 6.625
Main Switch Modules TMP3FB8R 4 20 66.5 6.625
Main Switch Modules TMPFB12R 10 36.5 66.5 19.5
Main Switch Modules TMPFT12R 10 36.5 66.5 19.5
Main Switch Modules TMP3FB12R 10 36.5 66.5 19.5
Main Switch Modules TMP3FT12R 10 36.5 66.5 19.5
Main Switch Modules TMP3FB16R 10 36.5 66.5 19.5
Main Switch Modules TMP3FT16R 10 36.5 66.5 19.5
Main Switch Modules TMP3FB20R 10 36.5 66.5 19.5
Main Switch Modules TMP3FT20R 10 36.5 66.5 19.5
Main Switch Modules TMPFB4RCLL 4 20 61 11.75
Main Switch Modules TMPFB6RCLL 4 20 61 11.75
Main Switch Modules TMPFB8RCLL 4 20 61 11.75
Main Switch Modules TMPFB12RCLLT 4 33.5 61 11.75
Main Switch Modules TMP3FB4RCLL 4 20 61 11.75
Main Switch Modules TMP3FB6RCLL 4 25.38 61 11.75
Main Switch Modules TMP3FB8RCLL 4 25.38 61 11.75
Main Switch Modules TMP3FB12RCLLT 33.5 61 11.875
Main Switch Modules TMPFB12RT 4 33.5 52.625 11.875
Main Switch Modules TMP3FB12RT 4 33.5 52.75 11.875
Main Lug Modules TMP3L4R 5 13.5 48.75 7
Main Lug Modules TMP3L6R 5 13.5 48.75 7
Main Lug Modules TMPL8R 4 20 47.625 11.75
Main Lug Modules TMP3L8R 4 20 47.625 11.75
Main Lug Modules TMPL12R 4 20 47.625 11.75
Main Lug Modules TMP3L12R 4 20 47.625 11.75
Main Lug Modules TMPL16R 32.875 60.125 11.4375
Main Lug Modules TMP3L16R 32.875 60.125 11.4375
Main Lug with Feed Through TMP3L12RCRIS 28.48 60.56 11.65
Main Lug with Feed Through TMP3L16RCRIS 28.48 60.56 11.65
Main Pull Box Modules TMPU4R 6 16.325 44.825 7.825
Main Pull Box Modules TMP3U4R 6 16.325 44.825 7.825
Main Pull Box Modules TMPU8R 7 24.325 46.825 11.825
Main Pull Box Modules TMP3U8R 7 24.325 46.825 11.825
Main Pull Box Modules TMPU12R 8 32.5 56.825 12
Main Pull Box Modules TMP3U12R 8 32.5 56.825 12
Elbow TMPE12 11 16 17.5 4.938
Elbow TMPE12A 11 12 17.5 4.938
1Figures referenced are on pages 2-29 and 2-30. Figures 1 through 8 have a removable top drip hood. Figure 4 has a removable top drip hood and open end wall..

2-28 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Modular Metering Section 2
Meter Mod III
Enclosure Knockout Dimensions

Knockouts
Symbol A B C D E F G H I J K L M
1 1
2 2
3
4
1 1 1 1
Conduit 114 114 114 114
Size 112 112 112 112 112 112
in 2 2 2 2 2 2 2
Inches 212 212 212 212 212 212
3 3 3 3 3
312 312 312 312
4 4 4 4
5

Figure 1 Figure 2 Figure 3

Figure 4 Figure 5 Figure 6

Rev. 11/13 www.geindustrial.com BuyLog Catalog 2-29


Data subject to change
without notice
Modular Metering Section 2
Meter Mod III
Enclosure Knockout Dimensions

Figure 7 Figure 8 Figure 9

Figure 10 Figure 11 Figure 12

2-30 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Section Updated 04 / 2016

Electric Vehicle Charging Stations Section 3

Introduction .....................................................................................................3-2
Selection Guide ..............................................................................................3-3
Commercial WattStation
Overview, Features and Benefits ........................................................3-4
WattStation Pedestal EV Charger
Specifications and Ordering Information ....................................3-5
WattStation Wall Mount EV Charger
Specifications and Ordering Information ....................................3-6
Commercial DuraStation
Overview, Features and Benefits ........................................................3-7
Specifications and Ordering Information........................................3-8
Connect Software
Overview, Features and Benefits ........................................................3-9
Specifications and Ordering Information.....................................3-10
Residential Charging Stations Wall Mount Units
Overview, Features and Benefits......................................................3-11
Specifications and Ordering Information.....................................3-12

Rev. 11/13 www.geindustrial.com BuyLog Catalog 3-1


Data subject to change
without notice
Electric Vehicle Charging Stations Section 3
Introduction

The Expanded EV Pipeline


Over the next five years, virtually every automobile manufacturer in
the world plans to introduce a plug-in hybrid or battery electric vehicle.
They will convert existing models and introduce new models.

A Total EV Infrastructure Solution


The charging stations where consumers power their EVs are just
the most visible element of the extensive infrastructure needed to
support the transition to energy-powered automobiles. In addition
to its EV charging stations, GE offers a wide range of large- and
small-scale electrical distribution products including transformers,
switchgear, switchboards, and residential load centers needed to
ensure end-to-end system protection and reliability.

GEs 100 years of innovation in the design and manufacture of


electrical distribution equipment means that you can depend on
GE products to help move power to EVs as efficiently and as
safely as possible and to take full advantage of smart grid
design and other emerging technologies. We have a full range
of electrical distribution products required to support EV
deployment, including:

Utility Supply

Utility Transformers Switchgear Switchboards


and Panelboards

Submetering

EV Charging Stations Load Centers General Purpose


Transformers

3-2 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Page Updated 04 / 2016
Electric Vehicle Charging Stations Section 3
Selection Guide

Introduction
Look to GEs broad-based expertise to make an integrated, connected, and stylish EV
charging solution a practical reality for your location. Our market knowledge and product
development has set the standard for user-friendly designs and reliability. GE EV charg-
ing stations offer

Convenience: Whether you need durability, modern style, wall-mounted or freestand-


ing units, software enabled, or simple charging functionality, GE connects you to the
most effective solution.
Safety First: WattStation delivers peace of mind with ground fault protection. It fea-
tures a NEMA 3R indoor/outdoor rating and meets all UL and fire safety standards.
Opportunity: If youre a commercial property manager in need of information on elec-
tricity usage, a fleet owner in search of better cost allocation data, or a retailer looking
to attract new customers, WattStation Connect cloud software will meet your needs.

WattStation WattStation
Pedestal Wall Mount DuraStation
Software Cloud Software Standard Optional Optional
Connectivity CAT5/WiFi/Cell Standard Optional Optional
Point of Sale (PayPal/CC) Standard Optional Optional
Access Control (RFID) Standard Optional Optional WattStation Pedestal
Custom Wraps Optional Optional Optional

WattStation Wall Mount

DuraStation

Rev. 11/13 www.geindustrial.com BuyLog Catalog 3-3


Data subject to change
without notice
Page Updated 04 / 2016
Electric Vehicle Charging Stations Section 3
Commercial WattStation
Features and Benefits

Overview
The GE Commercial WattStation line gives you a superior combi-
nation of design, style, and features for electric vehicle charging
systems. Available in a sleek pedestal or stylish wall mount, both
units feature GEs WattStation Connect software which lets you
manage your WattStation network remotely, enable EV drivers to
find stations at your facilities, provide payment options and gener-
ate valuable usage and user reports. Non-network wall mount
units for residential use are also offered.

Product Features and Benefits


Convenience
Retractable cord: The unique cord management system ensures
that the WattStations cord is easy and safe to stow away from
pedestrian walkways, providing protection between uses.
Modular upgrades: GE has developed the WattStation solution
so it can easily grow to meet your future needs. You can
receive upgrades for new features over-the-air so your
WattStation will always be up-to-date without having to
upgrade your equipment.

Wall Mount
Easy to use display panel and a wraparound cord management
system to keep the charger cord off the ground between uses.
Both hardwired and wall plug options are available.

Pedestal and Wall Mount


Connect Software: provides a user-friendly cloud-based web
application for owners to configure, control and monitor their
charging station network. Timely information about the state of
their charging stations gives owners the ability to diagnose and
manage problems remotely. The ability to define and set pricing
plans and manage user access (RFID) for the charging station is
also included.
Safety First: WattStation helps to deliver peace of mind with
ground fault protection and surge protection. It features
indoor/outdoor rating (NEMA 3R) and meets UL standards and
approvals including: NEC 625, UL 2231, 2251, 2594 and cUL
2231, 2594, SAE J1772.
Easy to use: The product offers Level II charging with service
needs of 208-240VAC at 40A. The sleek user interface and LED
indicator lights offer users a simple and clear way to identify
when the WattStation is available for use, or charging. Connected Access
Branded Wrap: For a small upcharge, a 3M vinyl wrap with three Communication options include CAT5 Ethernet, WiFi and cellular1.
year warranty can be added to the WattStation. All you provide A unique identification code (QR code) on each WattStation allows
is the artwork. drivers to scan the charger with their smartphone and
Warranty: The product comes with a three year parts warranty. WattStation, PlugShare or EV Connect mobile applications to
Extended parts warranties also available. access instructions on the charger, download charger status and
authorize charger use.

RFID is standard on all Networked WattStation models, and allows


users to gain authorization to the charger by waving a RFID card
in front of the RFID reader.
1Additional service contract required.

3-4 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Page Updated 04 / 2016
Electric Vehicle Charging Stations Section 3
Commercial WattStation
Pedestal Specifications and Ordering Information

Pedestal Specifications
SAE Compliant Level II per J1772
Vehicle Interface SAE J1772 EV connector
Cable Length 15.5 feet (as allowed by the NEC)
AC Charging Power Output 7.2kW (240VAC @ 30A)
Voltage and Current Rating 208-240VAC @ 30A
AC Power Input 208-240VAC requiring only Line 1, Line 2, and Earth ground
Short Circuit Rating 5kA @ 240VAC
Recommended Service Panel Breaker 2-pole 40A breaker on dedicated circuit
Ground Fault Protection Internal 20mA CCID w/ auto re-closure, does not require a GFCI in service panel
Communication Option CAT5 Ethernet, WiFi or Cellular (CDMA)
Metering Accuracy 2% accurate on voltage and current
RFID Reader HID Multi-Class RP15
Display Screen LED Icon
Standby Power 5W typ.
Outdoor Rated NEMA 3R
Safety Compliance (ETL Listing) UL 2231, UL 2251, UL 2594, cUL 2231, cUL 2594, NEC 625, SAE J1772
Surge Protection 6kV @ 3,000A
EMI Compliance FCC Part 15 Class A
Operating Temperature -30C to +50C ambient (Operating temp. limit for cord reel is -15C)
Operating Humidity Up to 95% non-condensing
Approximate Shipping Weights 120 lbs.
Dimensions 51.1"H x 14.9"D

Ordering Information
Type Connect Communication Product No.
Single Pedestal w/ Connect Yes CAT 5 EVWPR3GEXXGB
Single Pedestal w/ Connect Yes WiFi EVWPR3GWXXGB
Single Pedestal w/ Connect1 Yes Cellular (CDMA)1 EVWPR3GZXXGB
1Required Cellular Access (Annual) per J1772 Connector Yes Cellular (CDMA) EVSWWC124

Accessories
Type Product No.
EV Connect (annual per connector) EVSWWC126
RFID Access Cards - pack of 10 GE branded cards EVRCG10
Customized Vinyl Wrap - Factory installed EVWRAPSETUP

Standards Compliance
SAE J1772
NEC 625
UL 2231, 2251, 2594
NEMA and NIST
cUL 2594 and 2231

Rev. 11/13 www.geindustrial.com BuyLog Catalog 3-5


Data subject to change
without notice
Page Updated 04 / 2016
Electric Vehicle Charging Stations Section 3
Commercial WattStation
Wall Mount Specifications and Ordering Information

Wall Mount Specifications


SAE Compliant Level II per J1772
Vehicle Interface SAE J1772 EV connector
Cable Length 24.5 feet (as allowed by the NEC)
AC Charging Power Output 7.2kW (240VAC @ 30A)
Voltage and Current Rating 208-240VAC @ 30A
AC Power Input 208-240VAC requiring only Line 1, Line 2, and Earth ground
Short Circuit Rating 5kA @ 240VAC
Recommended Service Panel Breaker 2-pole 40A breaker on dedicated circuit
Ground Fault Protection Internal 20mA CCID w/ auto re-closure, does not require a GFCI in service panel
Communication Option CAT5 Ethernet, WiFi or Cellular (CDMA)
Metering Accuracy 2% accurate on voltage and current
RFID Reader HID Multi-Class RP15
Display Screen LED Icon
Standby Power 5W typ.
Outdoor Rated NEMA 3R
Safety Compliance (ETL Listing) UL 2231, UL 2251, UL 2594, cUL 2231, cUL 2594, NEC 625, SAE J1772
Surge Protection 6kV @ 3,000A
EMI Compliance FCC Part 15 Class A
Operating Temperature -30C to +50C ambient (Operating temp. limit for cord reel is -15C)
Operating Humidity Up to 95% non-condensing
Approximate Shipping Weights 45 lbs.
Dimensions 23.9 "H x 16.0 "W x 6.1"D

Ordering Information
Type Connect Communication Product No.
Wall Mount w/Connect Yes WiFi EVWWR3BWXCGB
Wall Mount w/Connect1 Yes Cellular (CDMA)1 EVWWR3BZXCGB
1Required Cellular Access (Annual) per J1772 Connector Yes Cellular (CDMA) EVSWWC124

Accessories
Type Product No.
EV Connect (annual per connector) EVSWWC126
RFID Access Cards - pack of 10 GE branded cards EVRCG10
Customized Vinyl Wrap - Factory installed EVWRAPSETUP

3-6 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Page Updated 04 / 2016
Electric Vehicle Charging Stations Section 3
Commercial DuraStation
Overview, RFID Option and Mounting Options

Overview
GE DuraStation is our most versatile line of electric vehicle
chargers. It offers a broad array of mounting options, user access
control and payment methods with the optional WattStation
Connect Software which includes an RFID reader. Rugged, durable
and time-tested, DuraStation has been successfully used in the
extreme heat of summer (rated to 50 degrees Celsius) to the dead
of winter (rated to -30 degrees Celsius).

Product Features and Benefits


Highly Versatile: DuraStation offers a broad array of options for
EV charging station operators. It is available in single and double
connector pedestals, and can be wall or pole mounted making
DuraStation ideal for any outdoor installation.
Safety First: DuraStation helps to deliver peace of mind with Double Pedestal Single Pedestal
ground fault protection and surge protection. It features
indoor/outdoor rating (NEMA 3R) and meets UL standards and
approvals including: NEC 625, UL 2231, 2251, 2594 and cUL
2231, 2594, SAE J1772.
User Interface: The sleek user interface and LED indicator lights
offer users a simple and clear way to identify when the
DuraStation is available for use, charging the EV, or if a fault has
occurred. Vacuum Fluorescent Display (VFD) screen shows
greetings, instructions and station messages.
Connect Software: DuraStation can be ordered with the
advanced Connect Software. Connect Software provides a user-
friendly cloud-based web application for owners to configure,
control and monitor their charging station network. Timely infor-
mation about the state of their charging stations gives owners
the ability to diagnose and manage problems remotely. The abil-
ity to define and set pricing plans and manage user access
(RFID) for the charging station is also included.
Branded Wrap: For a small upcharge, a 3M vinyl wrap with 3
year warranty can be added. All you provide is the artwork.
DuraStations come with a three year parts warranty. Extended
parts warranties also available.
Pole/Wall Mount Branded Wrap

Rev. 11/13 www.geindustrial.com BuyLog Catalog 3-7


Data subject to change
without notice
Page Updated 04 / 2016

Electric Vehicle Charging Stations Section 3


Commercial DuraStation
Features and Benefits, Specifications, Ordering Information

Product Features and Benefits (continued) Specifications


SAE Compliant Level II per J1772
The DuraStations basic features are upgradeable, resulting in a
Vehicle Interface SAE J1772 EV connector
robust and reliable solution for EV charging infrastructure. Cable Length 22 feet (as allowed by the NEC)
The cord holder keeps the cord organized and out of the way of AC Charging Power Output 7.2kW (240VAC @ 30A)
Voltage and Current Rating 208-240VAC @ 30A
parking spaces, sidewalks and streets. AC Power Input 208-240VAC requiring only Line 1, Line 2, and
LEDs display status: Green = Station active; Blinking green = Earth ground
Vehicle connected, not charging; Amber = Charging; Red = Fault Short Circuit Rating 5kA @ 240VAC
Recommended Service Panel Breaker Pole, Wall, Single Pedestal: 2-pole 40A breaker on
occurred. dedicated circuit
Option for a Radio Frequency Identification (RFID) reader: users Double Pedestal: (Qty. 2) 2-pole 40A breaker on
dedicated circuit
will gain charging authorization by waving RFID cards in front of
Ground Fault Protection Internal 20mA CCID w/ auto re-closure, does not
the readers. require a GFCI in service panel
Ethernet network offered for RFID authorization. Communication Option CAT5 Ethernet, WiFi or Cellular (CDMA)
Metering Accuracy 2% accurate on voltage and current
RFID software registers usage of the DuraStation, enabling data RFID Reader HID MultiClass RP15
collection and monitoring status of communication between Display Screen Vacuum Fluorescent Display
RFID and DuraStation. Standby Power 5W typ.
Outdoor Rated NEMA 3R
Vacuum Fluorescent Display (VFD) screen shows greetings, Safety Compliance (ETL Listing) UL 2231, UL 2251, UL 2594, cUL 2231, cUL 2594,
instructions and station messages. NEC 625, SAE J1772
Surge Protection 6kV @ 3,000A
Nuisance tripping avoidance and auto re-closure.
EMI Compliance FCC Part 15 Class B
Vehicle ground monitoring circuit. Operating Temperature -30C to +50C ambient
Single phase metering, displayed on included VFD. Operating Humidity Up to 95% non-condensing
Single Pedestal: 140 lbs.
A building ventilation interface signal can be provided to Double Pedestal: 175 lbs.
Approximate Shipping Weights
operate facility and garage fans when required. Pole: 75 lbs.
Wall: 75 lbs.
Single Pedestal: 51.1"H x 14.9"W x 13.8"D
Dimensions Double Pedestal: 51.1"H x 14.9"W x 13.8"D
Standards and Approvals Pole: 31.52"H x 11.82"W x 11.16"D
SAE J1772 Wall: 31.52"H x 11.82"W x 11.16"D

NEC 625
UL 2231, 2251, 2594 Ordering Information
cUL 2231, 2594 Type Connect Communication Product No.

NEMA and NIST Pole Mount No None EVPN3


Wall Mount No None EVWN3
Single Pedestal No None EVSN3
Double Pedestal No None EVDN3
Reference Publications Single Pedestal w/ Connect Yes CAT 5 EVDPR3GEXXGB
DuraStation Fact Sheet DET-834 Single Pedestal w/ Connect Yes WiFi EVDPR3GWXXGB
EV Infrastructure Brochure DEA-544 Single Pedestal w/ Connect1 Yes Cellular (CDMA)1 EVDPR3GZXXGB
DuraStation User Manual/Install Guide DEH-44160 Single Pedestal w/ Connect Yes CAT 5 EVDDR3GEXXGB
DuraStation Application Guide DET-743 Single Pedestal w/ Connect Yes WiFi EVDDR3GWXXGB
DuraStation and RFID Guide DET-750 Single Pedestal w/ Connect1 Yes Cellular (CDMA)1 EVDDR3GZXXGB
1Required Cellular Access

(Annual) per J1772 Connector Yes Cellular (CDMA) EVSWWC124

Accessories
Type Product No.
EV Connect (annual per connector) EVSWWC126
RFID Access Cards - pack of 10 GE branded cards EVRCG10
Customized Vinyl Wrap - Factory installed EVWRAPSETUP

3-8 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Page Updated 04 / 2016
Electric Vehicle Charging Stations Section 3
Connect
Advanced Network Management at your fingertips

Our Commerical WattStation and DuraStation EV chargers feature the ability to connect
to the cloud for remote monitoring and management of your charging stations.

Services WattStation Connect EV Connect


Pricing Free Yearly subscription
Point of Sale Paypal and Pay w/ Plug Share Mobile payments (PayPal, Credit Card)
Driver Services Location, status, payment Reservations, queuing, reviews, guest codes
Pricing Per session, kWh, hour Vary by time, user, peak rates
Utility Services None Demand response, open ADR
Reporting Usage, transactions, access Sustainability metrics, schedules
Active Monitoring None 24x7 uptime monitoring
Support 8am to 10pm EST, Mon-Fri 24x7

Overview
Advanced Network Capabilities: WattStation Connect software is a web-enabled, cloud-
based system to configure and manage your optionally equipped GE WattStation or GE
DuraStation, offering user and usage management, controlled access and third party
payment processing. Our Application Programming Interface (API) helps you to inter-
face with your own building or fleet management systems including email. You just
choose the communications platform (CAT5, WiFi or available Cellular1).

EV Connect
Through our partnership with EV Connect, GE is proud to provide additional network
management capabilities that enhance a site operators ability to control many aspects
of the charge station.

Product Features and Benefits


Manage. Monitor. Maintain: Provides a user-friendly cloud-based web application for
owners to configure, control and monitor their charging station network. Timely infor-
mation about the state of their charging stations gives owners the ability to diagnose
and manage problems remotely.
Simple Access Control: Provides owners with the ability to restrict access to their sta-
tions through the use of an RFID card. Our simple to use web interface makes it easy to
grant access to drivers.
Set Pricing: Provides owners with the ability to set pricing for their stations through the
use of a desktop web-enabled system. Choose the price schedule to fit your needs;
change it when your needs change with just a few clicks!
Offer Payment Options: Provides one of the most flexible payment options in the
market. WattStation and DuraStation equipped with WattStation Connect accommo-
date payments through PayPal and Credit Card payments through iPhone and
Android devices.
Open Platform: Web Services enable you to integrate data from the WattStation net-
work into your existing systems using an Application Programming Interface (API). Our
unique open platform has allowed multiple 3rd parties to develop new features and
content for your benefit.
1Cellular access requires an annual fee see your authorized GE distributor for pricing details.

Rev. 11/13 www.geindustrial.com BuyLog Catalog 3-9


Data subject to change
without notice
Page Updated 04 / 2016

Electric Vehicle Charging Stations Section 3


Connect
Specifications and Ordering Information

Specifications
Registration Drivers: Register by entering your name, email address and create a password
(terms and conditions apply)
Business Owners: Users may also request access to a business owner domain.
Find Station Locate stations based on address, zip code or dragging the map to your specific area of interest.
Users will be able to view stations, availability and station details (pricing, address, owner name, etc)
Dashboard Take your EV infrastructure project to the next level with the WattStation EV charger and WattStation
Connect software. This integrated hardware and software solution can help manage your charging
stations remotely, enable EV drivers to find stations at your facilities, generate valuable reports, and
engage with customers in new and meaningful ways.
Users Authorize users, define user groups, manage user accounts
Stations Provision and set-up of new installations, manage stations and update information, and set-up
automatic message notifications.
Planning/Pricing Options Define and create pricing models for stations and user groups. Options include:
Pay Flat Rate. E.g., set a fixed price, regardless of the duration of the charging session.
Pay As You Charge. E.g., set a fixed price for every hour your driver will charge his vehicle.
Pay By Time. E.g., set a fixed price based on the duration (hourly) of each transaction.
Other customized options available.
Access Cards Management Manage access cards and user assignments for your charging stations. GE offers a 10-pack Access
Card that Owners can purchase and distribute for free authorized access.
Reports Generate various reports for station operators, including revenue, energy usage, system faults, and
per driver charge session.
Settings Update your account information (name, address, contact info, password, etc.) and allow EV Driver to
enroll with PayPal or PlugShare for other pricing options, set up permissions and accept payment for
EV charging by mobile phone.
Mobile Application (EV Driver) This mobile app provides three functionalities:
Find a Station
Pay for Usage
Account management
Mobile Application Availability GE WattStation
PlugShare
Apple App Store
Android Market

Ordering Information
Description Product No.
WattStation Connect Cellular Data Access Fee EVSWWC124
EV Connect (annual per connector) EVSWWC126
RFID Access Cards pack of 10 GE branded cards EVRCG10

3-10 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Page Updated 04 / 2016
Electric Vehicle Charging Stations Section 3
Residential Charging Stations Wall Mount Units
Overview, Features and Benefits

A perfect fit in any garage


GE's wall mount EV chargers provide an added convenience for EV owners in public or
private parking garages. At home, EV owners benefit from their simplicity and conven-
ience. While they are built for garages, the wall mount stations are NEMA 3R rated so
they are rugged enough to be installed outdoors.

WattStation DuraStation
Level 2 Charging Standard Standard
7.2kWh Rating Standard Standard
Outdoor Rating Standard Standard
NEMA 6-50P Installation Optional N/A
Cord Length 20 feet 18 feet
3 year warranty Standard Standard
Custom Wraps Optional N/A

Overview
The WattStation Wall Mount design is suitable for various commercial and residential
locations. This product offers Level II charging, which is capable of reducing charge time
from 12-18 hours to 4-8 hours, with service needs of 208-240Vac at 40A, assuming a WattStation Wall Mount
24kWh battery and a full-cycle charge.

WattStation Wall Mount Product Features and Benefits


The WattStation has a wide variety of features that make it reliable and beneficial to
users in many different contexts.
Sleek and modern design
Wall mounted application
The cord wraps conveniently around the unit keeping it organized and off of
the ground
Features a NEMA 3R plastic exterior (Available on EVWSWBC-CP01 only)
Option for hardwired unit or plug in unit
A power button allows the user to completely shut off power to the charging station,
resulting in zero energy consumption (Available on EVWSWBC-CP01 only)
A green backlit charging icon will illuminate to signal that the vehicle is charging, and a
red backlit icon illuminates to signal a fault has been detected
An LED light surrounds the connector inlet and will illuminate white when the charging
station is powered on DuraStation Wall Mount
Mounting brackets are designed for extremely easy install
An enclosure lock is featured on the mounting brackets to prevent unwanted removal
of the enclosure from the wall
Nuisance tripping avoidance and auto re-closure
Vehicle Ground monitoring circuit

Standards Compliance
SAE J1772
NEC 625
cETL and ETL listed
UL 2594
cUL 2594
NEMA and NIST
ADA Compliance

Reference Publications
WattStation Wall Mount Brochure DEA-528
WattStation Wall Mount Application Guide DET-746
WattStation Wall Mount Fact Sheet DEQ-167
WattStation Wall Mount User Manual DEA-533

Rev. 11/13 www.geindustrial.com BuyLog Catalog 3-11


Prices and data subject
to change without notice
Page Updated 04 / 2016
Electric Vehicle Charging Stations Section 3
Residential Charging Stations
Specifications and Ordering Information

WattStation Wall Mount Specifications


SAE Compliant Level II per J1772
Vehicle Interface SAE J1772 EV connector
Cable Length 24.5 feet (as allowed by the NEC)
W
AC Charging Power Output 7.2kW (240VAC @ 30A)
Voltage and Current Rating 208-240VAC @ 30A
AC Power Input 208-240VAC requiring only Line 1, Line 2, and Earth ground
Short Circuit Rating 5kA @ 240VAC D
Recommended Service Panel Breaker 2-pole 40A breaker on dedicated circuit
H
Ground Fault Protection Internal 20mA CCID w/ auto re-closure, does not require a GFCI in service panel
Metering Accuracy 2% accurate on voltage and current
Display Screen LED Icon
Standby Power 5W typ.
Outdoor Rated NEMA 3R
Safety Compliance (ETL Listing) UL 2231, UL 2251, UL 2594, cUL 2231, cUL 2594, NEC 625, SAE J1772 Dimensions:
Surge Protection 6kV @ 3,000A (W) 16 in. / 40.6 cm
EMI Compliance FCC Part 15 Class A
Operating Temperature -30C to +50C ambient
(H) 23.9 in. / 61.0 cm
Operating Humidity Up to 95% non-condensing (D) 6.1 in. / 15.2 cm
Approximate Shipping Weights 45 lbs.
Dimensions 23.9 "H x 16.0 "W x 6.1"D

DuraStation Wall Mount Specifications


SAE Compliant Level II per J1772
Vehicle Interface SAE J1772 EV connector W
Cable Length 18 feet (as allowed by the NEC)
AC Charging Power Output 7.2kW (240VAC @ 30A)
Voltage and Current Rating 208-240VAC @ 30A
AC Power Input 208-240VAC requiring only Line 1, Line 2, and Earth ground
Short Circuit Rating 5kA @ 240VAC
D H
Recommended Service Panel Breaker 2-pole 40A breaker on dedicated circuit
Ground Fault Protection Internal 20mA CCID w/ auto re-closure, does not require a GFCI in service panel
Metering Accuracy 2% accurate on voltage and current
Standby Power 5W typ.
Outdoor Rated NEMA 3R
Safety Compliance (ETL Listing) UL 2231, UL 2251, UL 2594, cUL 2231, cUL 2594, NEC 625, SAE J1772
Dimensions:
Surge Protection 6kV @ 3,000A (W) 11.25 in. / 28.6 cm
EMI Compliance FCC Part 15 Class A (H) 12 in. / 30.5 cm
Operating Temperature -30C to +50C ambient (D) 6.38 in. / 16.2 cm
Operating Humidity Up to 95% non-condensing
Approximate Shipping Weights 19.4 lbs.
Dimensions 12"H x 11.25"W x 6.38"D

Ordering Information
Type Product No.
WattStation Wall Mount Plug In EVWSWBC-CP01
WattStation Wall Mount Hardwired EVWSWBH-CP03
DuraStation Wall Mount Hardwired EVDSWGH-CP01

3-12 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Section Updated 01 / 2017

Safety Switches Section 4

Quick Selection Guide, Enclosure Types...................................4-2


General Duty, Type TG .................................................................4-5
Heavy Duty, Type TH....................................................................4-7
Heavy Duty Stainless Steel, Type TH ......................................4-11
Mill Duty, Type TH.......................................................................4-13
Double Throw Switches, Type TC, TDT....................................4-15
Emergency Power Transfer Switches, Type TC .....................4-18
AC Disconnects ..........................................................................4-19
Accessories: NEMA Type 1 and 3R Enclosures ......................4-20
Accessories: NEMA Type 4/4X, 12 and
Mill Duty Enclosures.............................................................4-22
Additional Accessories ..............................................................4-24
Enclosure and Knockout Dimensions ............4-26 through 4-36

For more information on these products, order publications from


Section 28.

Rev. 11/13 www.geindustrial.com BuyLog Catalog 4-1


Data subject to change
without notice
Safety Switches Section 4
Spec-Setter Safety Switches
Quick Selection Guide

General Duty Safety Switch Short Circuit Ratings


UL Listed Fusing
Maximum System Voltage Ampere Rating Switch Type Class Withstand Rating (rms Sym Amps) Enclosure Type
K 10,000
Fusible2 H 10,000
240 Vac R 100,000 N1
30-6001
250 Vdc K 10,000 N3R
Non-fusible H 10,000
R 10,000

TG4322

Heavy Duty Safety Switch Short Circuit Ratings


UL Listed Fusing
Maximum System Voltage Ampere Rating Switch Type Class Withstand Rating (rms Sym Amps) Enclosure Type
H 10,000
Fusible R 200,0004 N1
J 200,0004 N3R
600Vac L3 100,000
30-1200 N4/4X
600Vdc H 10,000 N5
R 10,000 N12
Non-fusible1
J 10,000
L3 10,000

TH3361SS

Double Throw Safety Switch Short Circuit Ratings


UL Listed Fusing
Maximum System Voltage Ampere Rating Switch Type Class Withstand Rating (rms Sym Amps) Enclosure Type
R 100,000
Fusible J 100,000
T 100,000 N1
600Vac 30-1200 L 100,000 N3R
R 10,000 N4X
J 10,000
Non-fusible1
T 10,000
L 10,000
1 Non-fusible switch withstand ratings apply when protected by corresponding listed fuse type.
2 Class R fuse is not available for 400A or 600A General Duty switches.
3 Class L fuses are only applicable when used with 800 and 1200A Type TC safety switches.
4 Unless otherwise noted. TC10323R

TDT3362

4-2 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Safety Switches Section 4
Spec-Setter Safety Switches
Quick Selection Guide

Enclosure Types
Type 1Enclosures constructed for indoor use to provide a degree of protection to
personnel against incidental contact with the enclosed equipment and to provide a
degree of protection against falling dirt.
Type 3REnclosures constructed for either indoor or outdoor use to provide a degree
of protection to personnel against incidental contact with the enclosed equipment; to
provide a degree of protection against falling dirt, rain, sleet, and snow; and that will
be undamaged by the external formation of ice on the enclosure
Type 4Enclosures constructed for either indoor or outdoor use to provide a degree
of protection to personnel against incidental contact with the enclosed equipment;
to provide a degree of protection against falling dirt, rain, sleet, snow, windblown dust,
splashing water, and hose-directed water; and that will be undamaged by the external
formation of ice on the enclosure.
Type 4XEnclosures constructed for either indoor or outdoor use to provide a degree
of protection to personnel against incidental contact with the enclosed equipment; to
provide a degree of protection against falling dirt, rain, sleet, snow, windblown dust,
splashing water, hose-directed water, and corrosion; and that will be undamaged by
the external formation of ice on the enclosure.
Type 5Enclosures constructed for indoor use to provide a degree of protection to
personnel against incidental contact with the enclosed equipment; to provide a degree
of protection against falling dirt; against settling airborne dust, lint, fibers, and flyings;
and to provide a degree of protection against dripping and light splashing of liquids.
Type 12Enclosures constructed (without knockouts) for indoor use to provide a degree
of protection to personnel against incidental contact with the enclosed equipment; to
provide a degree of protection against falling dirt; against circulating dust, lint, fibers,
and flyings; and to provide a degree of protection against dripping and light splashing
of liquids.
Application Note: For applications of disconnecting means in motor circuit applications,
disconnect must be sized based on ampacity per NEC 430-110, but not less than 115%
of Motor Name-Plate current.

Comparison of Specific Applications of Enclosures


for Indoor Nonhazardous Locations
Type of Enclosure
Provides a Degree of Protection Against the Following Environmental Conditions 1* 4 4X 5 12
Incidental contact with the enclosed equipment X X X X X
Falling dirt X X X X X
Falling liquids and light splashing X X X X
Circulating dust, lint, fibers, and flyings** X X X
Settling airborne dust, lint, fibers, and flyings** X X X X
Hosedown and splashing water X X
Oil and coolant seepage X
Corrosive agents X

*These enclosures may be ventilated.


** These fibers and flyings are nonhazardous materials and are not considered Class III type ignitable fibers or
combustible flyings. For Class III type ignitable fibers or combustible flyings see the National Electrical Code,
Article 500.

Applications of Enclosures for Outdoor Nonhazardous Locations


Type of Enclosure
Provides a Degree of Protection Against the Following Environmental Conditions 3R* 4 4X
Incidental contact with the enclosed equipment X X X
Rain, snow, and sleet** X X X
Windblown dust, lint, fibers, and flyings X X
Hosedown X X
Corrosive agents X

* These enclosures may be ventilated.


** External operating mechanisms are not required to be operable when the enclosure is ice covered.

Rev. 11/13 www.geindustrial.com BuyLog Catalog 4-3


Data subject to change
without notice
Safety Switches Section 4
Spec-Setter Safety Switches
Quick Selection Guide

Product Number Structure

T H N 3 3 6 1 R DC
GE Identification

Duty Level Other Features


H= Heavy Duty B= Bottom Feed (240V, TH, Type 1, 200-600A)
G= General Duty CL= Copper Lug
C= Non-Fusible Double Throw1 DC= Max DC Voltage600V
D= Fusible Double Throw F= Farm Switch
Ampere Rating W= Viewing Window Option
Fusing 1= 30A
N= Non-Fusible 2= 60A
T= Fusible Double Throw 3= 100A Enclosure Type
Blank= Fused 4= 200A Blank= NEMA 1
5= 400A R= NEMA 3R
Number of Wires 6= 600A SS= NEMA 4/4X Stainless Steel Type 304
2, 3, 4, 6 7= 800A SS316= NEMA 4/4X Stainless Steel Type 316
8= 1200A SSW= Stainless Steel with Viewing Window
Number of Poles J= NEMA 5/12
2, 3, 6 Maximum Voltage
M= Mill Duty NEMA 12
2= 240V, 6= 600V
1 800A and 1200A non-double throw safety switches also use the C nomenclature

Note: This information is provided for interpreting numbers. It should not be used to build product numbers.

4-4 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Safety Switches Section 4
General Duty, Type TG
Spec-Setter Safety Switches
30-600 Amperes
240 Volts AC
250 Volts DC
N

Type TG Switches
Designed for residential or light commercial applications
where duty is not severe
30-600 amps Safety
Fusible, Two-pole, 120/240 and 240 Volts AC; 250 Volts DC;
240Vac / 250Vdc maximum in fusible or non-fusible units SwitchesThree-wire switching neutral, 240 Volts AC
NEMA Type 1 (indoor) or NEMA Type 3R (outdoor) enclosures
Direct-drive, quick-make, quick-break mechanism snaps
contacts open and closed providing positive ON/OFF indication
Self-leveling, three-point mounting system
Integral cover interlock
Visible confirmation of plated blade contact positions
Spring reinforced fuse clips assure reliable contact for
cool operation. Suitable for Class H, K, J or R fuses,
where applicable.
UL Listed short-circuit rating is 10,000 rms symmetrical N
amps standard
With Class R fuses and fuse kits installed, 30-200 amp switches
have UL Listed short circuit rating of 100,000 rms symmetrical
amps
UL Listed as service entrance equipment when installed in
accordance with the National Electric Code Fusible, Four-wire switching neutral, 208/120 and 240 Volts AC

All GE General Duty safety switches


carry the following certifications:
UL Listed and cUL Listed
(UL98 Enclosed Switches/CSA-C22.2 No. 4-04)
Federal Specification WS-865C
NEMA Enclosed Safety Switch Standard KS1-2013
Seismic Certified

No Fuse, Two-pole, 240 Volts AC; 250 Volts DC (100-600 amps only);
Three-pole, 240 Volts AC or Two-pole with Switching Neutral

Rev. 11/13 www.geindustrial.com BuyLog Catalog 4-5


Data subject to change
without notice
Safety Switches Section 4
General Duty, Type TG
Spec-Setter Safey Switches
30-600 Amperes
240 Volts AC
250 Volts DC

General Duty Safety Switches


Product Number Horsepower Rating DC Hp Neutral Kit Insulated,
NEMA Type 1 NEMA Type 3 Single-Phase 240 Vac Three-Phase 240 Vac 250 Vdc Groundable and
Amperage Rating Indoor Outdoor Standard Fuse Time Delay Standard Fuse Time Delay Standard Fuse Bondable
Fusible / 2 Pole / 3 Wire / 240V / 50/60 Hz
30 TG3221 TG3221R 1.5 3 5
60 TG3222 TG3222R 3 10 10
100 TG3223 TG3223R 7.5 15 20
N Factory Installed
200 TG32241 TG3224R 15 15
400 TG32251,2 TG3225R2
600 TG32261,2 TG3226R2

Fusible / 3 Pole / 4 Wire /240V / 50/60 Hz


30 TG4321 TG4321R 1.5 3 3 7.5 5
60 TG4322 TG4322R 3 10 7.5 15 10
100 TG4323 TG4323R 7.5 15 15 30 20
N Factory Installed
200 TG43241 TG4324R 15 15 25 50
400 TG43251,2 4 50 100
600 TG43261,2 4 75 100

Product Number Horsepower Rating DC Hp Neutral Kit Insulated,


NEMA Type 1 NEMA Type 3 Single-Phase Three-Phase 250 Vdc Groundable and
Amperage Rating Indoor Outdoor 240 Vac Standard Standard Bondable
Non-Fusible / 3 Pole / 3 Wire / 240V / 50 /60 Hz
30 TGN3321 TGN3321R 3 7.5 5 TNI21
60 TGN33223 TGN3322R3 10 15 10
100 TGN33233 TGN3323R3 15 30 20
200 TGN33241 TGN3324R 15 50 TNIA64
400 TGN33251,2 4 100 TNI65 or TNI65A
600 TGN33261,2 4 100 TNI66

For Type 3R Enclosure: 30-200 amp devices have removable closing cap. Order hubs for these devices separately on page 4-25.
Larger amp devices require field cut openings and customer-supplied hub.
General Duty safety switches are not suitable for use as service equipment in Canada. Use Heavy Duty safety switches.
1 Add "B" suffix for factory reversed bottom feed. (e.g., TG3224B.) UL Listed.
2 Single make single break mechanism
3 Not suitable for use as service equipment. Solid neutral not available.
4 NEMA Type 3R Fusible or Non-Fusible versions, 400-600 ampere rating, available in heavy duty, type TH models. See pages 4-8 to 4-10.

4-6 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Safety Switches Section 4
Heavy Duty, Type TH
Spec-Setter Safety Switches
30-1200 Amperes
240 Volts AC
250 Volts DC
N

Type TH Switches
Designed for commercial and industrial applications where
safety, high performance and continuity of service are essential Fusible, Two-pole, Fusible,
30-1200 amps 240 Volts AC; 250 Volts DC Four-wire switching neutral,
600Vac maximum, 600Vdc maximum in fusible or non-fusible and Fusible Two-pole, 208/120 and 240 Volts AC
units 600 Volts DC,
NEMA Type 1 (indoor), Type 3R (outdoor), Type 4/4X (water and (2 poles in series for 600 Vdc)
dust-tight, corrosion resistant) or Type 5/12 (drip and dust-tight)
enclosures
Donut handle ideal for hook stick operation and accepts
3 padlocks in the OFF position
Direct-drive, quick-make, quick-break mechanism snaps con-
tacts open and closed providing positive ON/OFF indication N
Self-leveling, three-point mounting system
Coin-proof, defeatable interlock
Visible confirmation of plated blade contact positions
Spring reinforced fuse clips assure reliable contact for cool
operation. Suitable for Class H, K, J or R fuses, where applicable. Fusible, Three-pole, Non-fusible,
With Class R fuses or J fuses, 30-600 amp switches have UL Three-wire switching neutral, Two-pole, 600 Volts DC
Listed short circuit rating of 200,000 rms symmetrical amps 120/240 and 240 Volts AC
Switches rated 800-1200 amps use Class L fuses and have a
UL Listed short circuit rating of 100,00 rms symmetrical amps
UL Listed as service entrance equipment when installed in
accordance with the National Electric Code

All GE Heavy Duty safety switches


carry the following certifications:
UL Listed and cUL Listed
(UL98 Enclosed Switches/CSA-C22.2 No. 4-04)
Federal Specification WS-865C
NEMA Enclosed Safety Switch Standard KS1-2013 Fusible, Three-pole, Non-fusible,
Seismic Certified 240 Volts AC Three-pole, 480 and
480, 480Y/277 and 600 Volts 600 Volts AC-250 Volts DC
AC-250 Volts DC or Two-pole with
switching neutral

Rev. 11/13 www.geindustrial.com BuyLog Catalog 4-7


Data subject to change
without notice
Safety Switches Section 4
Heavy Duty, Type TH
Spec-Setter Safety Switches
30-1200 Amperes
240 Volts AC
250 Volts DC

Heavy Duty Safety Switches


Product Number Horsepower Rating DC Hp
NEMA Type 1 NEMA Type 3R Single-Phase 240 Vac Three-Phase 240 Vac 250 Vdc
Amperage Rating Indoor Outdoor NEMA Type 5, 12 Standard Fuse Time Delay Standard Fuse Time Delay Standard Fuse
Fusible / 2 Pole / 3 Wire / 240V / 50/60 Hz (Neutral factory installed)
30 TH3221 TH3221R TH3221J4 1.5 3 5
60 TH3222 TH3222R TH3222J4 3 10 10
100 TH3223 TH3223R TH3223J4 7.5 15 20
200 TH32241,2 TH3224R2 TH3224J4 15 40
N
400 TH32251,2 TH3225R2 TH3225J 50 125 50
600 TH32261,2 TH3226R2 TH3226J 75 200 50
800 TC722673,6,7 TC72267R3,6,7
1200 TC722683,6,7 TC72268R3,6,7

Product Number Horsepower Rating DC Hp


NEMA Type 1 NEMA Type 3R Single-Phase 240 Vac Three-Phase 240 Vac 250 Vdc
Amperage Rating Indoor Outdoor NEMA Type 5, 12 Standard Fuse Time Delay Standard Fuse Time Delay Standard Fuse
Fusible / 3 Pole / 3 Wire / 240V / 50/60 Hz
30 TH3321J4 1.5 3 3 7.5 5
60 TH3322J4 3 10 7.5 15 10
400 TH33251 TH3325R 50 125 50
600 TH33261 TH3326R 75 200 50
Fusible / 3 Pole / 4 Wire / 240V / 50/60 Hz (Neutral factory installed)
30 TH4321 TH4321R TH4321J4 1.5 3 3 7.5 5
60 TH4322 TH4322R TH4322J4 3 10 7.5 15 10
100 TH4323 TH4323R TH4323J4 7.5 15 15 30 20
N
200 TH4324 1,2 TH4324R2 TH4324J4 15 25 60 40
400 TH4325 1,2 TH3325R5,8 TH4325J 50 125 50
600 TH43261,2 TH3326R5,9 TH4326J 75 200 50

Heavy Duty Safety Switches 6-Pole


Product Number Horsepower Rating DC Hp
NEMA Type 1, 3R, 5, 12 Single-Phase 240 Vac Three-Phase 240 Vac 250 Vdc
Amperage Rating Indoor/Outdoor Standard Fuse Time Delay Standard Fuse Time Delay Standard Fuse
Fusible / 6 Pole / 6 Wire / 240V / 50/60 Hz
30 TH6621 1.5 3 3 7.5 5
60 TH6622 3 10 7.5 15 10
100 TH6623 7.5 15 15 30 20
200 TH6624 15 25 60 40

1 Type 1 Enclosure: 200-600 Amp devices available factory reversed for bottom feed. Add "B" suffix.
2 For switches CSA Certified for service entrance, add C suffix.
3 For switches suitable for service entrance applications in Canada, order TH3267C, TH3267RC, TH3268C and TH3268RC.
4 Available with Viewing Window. Add "W" suffix.
5 For switches suitable for service entrance applications in Canada, order TH4325RC and TH4326RC.
6 Rated 600 Vac only. Accepts Class L fuses only. Type HD electrical performance does not apply.
7 3 wire with neutral kit ordered separately. For 800A use TNI67; for 1200A use TNI68A.
8 4 wire with neutral kit ordered separately. For 400A use TNI65 or TNI65A.
9 4 wire with neutral kit ordered separately. For 600A use TNI66.

Note: Many Heavy Duty Switches are available with a Stainless Steel enclosure. See page 4-12.

4-8 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Safety Switches Section 4
Heavy Duty, Type TH
Spec-Setter Safety Switches
30-1200 Amperes
240 Volts AC
250 Volts DC

Heavy Duty Safety Switches


Product Number Horsepower Rating DC Hp
NEMA NEMA Three-Phase 240 Vac Single-Phase 480 Vac Three-Phase 480 Vac Single-Phase 600 Vac Three-Phase 600 Vac 125 Vdc 250 Vdc
Amperage Type 1 Type 3R Standard Time Standard Time Standard Time Standard Time Standard Time
Rating Indoor Outdoor Fuse Delay Fuse Delay Fuse Delay Fuse Delay Fuse Delay Standard Fuse
Fusible / 2 Pole / 2 Wire / 600V / 50/60 Hz
800 TC722671,2,7 TC72267R1,2,7
1200 TC722681,2,7 TC72268R1,2,7
Fusible / 3 Pole / 3 Wire / 600V / 50/60 Hz
TH3361 TH3361R
30 TH3361RF5 7.5 3 7.5 5 15 3 10 7.5 20 5
TH3361RF25
TH3362 TH3362R
60 5 20 15 30 10 25 15 50 5 10
TH3362RF5
100 TH3363 TH3363R 10 30 25 60 15 40 30 75 20
200 TH33643 TH3364R6 25 50 50 125 30 50 60 150 40
400 TH33653 TH3365R 50 125 100 250 125 350 50
600 TH33663 TH3366R 75 200 150 400 200 500 50
800 TC723672,4 TC72367R4
1200 TC723682,4 TC72368R4
Fusible / 3 Pole / 4 Wire / 600V / 50/60 Hz CSA Certified for service entrance (Neutral factory installed)
200 TH4364C TH4364RC 25 50 50 125 30 50 60 150 40
400 TH4365C TH4365RC 50 125 100 250 125 350 50
N
600 TH4366C TH4366RC 75 200 150 400 200 500 50
800 TH4367C TH4367RC
1200 TH4368C TH4368RC

Product Number Horsepower Rating DC Hp


NEMA NEMA Three-Phase 240 Vac Single-Phase 480 Vac Three-Phase 480 Vac Single-Phase 600 Vac Three-Phase 600 Vac 125 Vdc 250 Vdc
Amperage Type 5, 12 Type 3R, 5, 12 Standard Time Standard Time Standard Time Standard Time Standard Time
Rating Indoor Outdoor Fuse Delay Fuse Delay Fuse Delay Fuse Delay Fuse Delay Standard Fuse
Fusible / 3 Pole / 3 Wire / 600V / 50/60 Hz
30 TH3361J6 TH3361JR 7.5 3 7.5 5 15 3 10 7.5 20 5
60 TH3362J6 TH3362JR 5 20 15 30 10 25 15 50 5 10
100 TH3363J6 TH3363JR 10 30 25 60 15 40 30 75 20
200 TH3364J6 TH3364JR 25 50 50 125 30 50 60 150 40
400 TH3365J TH3365JR 50 125 100 250 125 350 50
600 TH3366J TH3366JR 75 200 150 400 200 500 50

Heavy Duty Safety Switches 6-Pole


Product Number Horsepower Rating DC Hp
Single-Phase 480 Vac Three-Phase 480 Vac Single-Phase 600 Vac Three-Phase 600 Vac 250 Vdc
Amperage NEMA Type 1, 3R, 5, 12 Standard Time Standard Time Standard Time Standard Time
Rating Indoor/Outdoor Fuse Delay Fuse Delay Fuse Delay Fuse Delay Standard Fuse
Fusible / 6 Pole / 6 Wire / 600V / 50/60 Hz
30 TH6661 3 7.5 5 15 3 10 7.5 20 5
60 TH6662 5 20 15 30 10 25 15 50 10
100 TH6663 10 30 25 60 15 40 30 75 20
200 TH6664 25 50 50 125 30 50 60 150 40

1 3 wire with neutral kit ordered separately. For 800A use TNI67; for 1200A use TNI68A.
2 Rated 600 Vac only. Accepts Class L fuses only. Type HD electrical performance does not apply.
3 Type 1 Enclosure: 200-600 Amp devices available, factory reversed for bottom feed. Add B suffix.
4 4 wire with neutral kit ordered separately. For 800A use TNI67; for 1200A use TNI68A.
5 Farm Switch with oversize Type 3R enclosure with vertical hinge. See page 4-28 for dimensions.
6 Available with Viewing Window. Add W suffix.
7 For switches suitable for service entrance applications in Canada, order TH3267C, TH3267RC, TH3268C and TH3268RC.

Rev. 11/13 www.geindustrial.com BuyLog Catalog 4-9


Data subject to change
without notice
Safety Switches Section 4
Heavy Duty, Type TH
Spec-Setter Safety Switches
30-1200 Amperes
240, 480, 600 Volts AC
600 Volts DC

Heavy Duty Safety Switches


Product Number Horsepower Rating DC Hp
Amperage NEMA NEMA NEMA Single-Phase Three-Phase Single-Phase Three-Phase Single-Phase Three-Phase 250 Vdc
Rating Type 1 Indoor Type 3R Outdoor Type 5, 12 240 Vac Standard 480 Vac Standard 600 Vac Standard Standard
Non-Fusible / 3 Pole / 3 Wire / 240V / 50/60 Hz
30 THN3321 3 10 5
Non-Fusible / 3 Pole / 3 Wire / 600V / 50/60 Hz
THN33612 THN3361R THN3361J2,3
30 THN3361RF4 3 10 7.5 20 10 30 5
THN3361RF24
THN33622 THN3362R THN3362J2,3
60 10 20 20 50 25 60 10
THN3362RF4
100 THN33632 THN3363R THN3363J2,3 20 40 30 75 40 100 20
200 THN33641,2 THN3364R THN3364J3 30 60 50 125 50 150 40
400 THN33651 THN3365R THN3365J 125 250 350 50
600 THN33661 THN3366R THN3366J 200 400 500 50
800 TC36367
1200 TC36368

Heavy Duty Safety Switches 6-Pole


Non-Fusible / 6 Pole / 6 Wire / 600V / 50/60 Hz
30 THN6661 3 7.5 15 10 20 5
60 THN6662 10 20 30 25 50 10
100 THN6663 15 30 60 40 75 20
200 THN6664 15 50 125 50 150 40
1 Type 1 Enclosure: 200-600 Amp devices available factory reversed for bottom feed. Add "B" suffix.
2 Available with Copper Lug. Add "CL" suffix
3 Available with Viewing Window. Add "W" suffix.
4 Farm switch with oversize Type 3R enclosure and vertical hinge. See page 4-28 for dimensions.

DC Rated Heavy Duty Safety Switches


Product Number DC Horsepower Ratings
Amperage NEMA NEMA NEMA 125 Vdc 250 Vdc 600 Vdc
Rating Type 1 Indoor Type 3R Outdoor Type 5, 12 Standard Fuse Time Delay Standard Fuse Standard Fuse Time Delay
Fusible / 2 Pole / 2 Wire / 600Vdc / 50/60 Hz
30 TH2261DC TH2261RDC TH2261JDC 2 3 5 10 15
60 TH2262DC TH2262RDC TH2262JDC 5 10 25
100 TH2263DC TH2263RDC TH2263JDC 20 25
Non-Fusible / 2 Pole / 2 Wire / 600Vdc / 50/60 Hz
30 THN2261DC THN2261RDC THN2261JDC 3 5 15
60 THN2262DC THN2262RDC THN2262JDC 5 10 25
100 THN2263DC THN2263RDC THN2263JDC 20 25

Interlocked Receptacle Switches


Product Number
Amperage NEMA Type 5, 12 Receptacle Mating
Rating Indoor NEMA Type 4/4X Manufacturer Receptable Horsepower Rating
Fusible / 3 Pole / 3 Wire / 600V / 50/60 Hz
60 TH3362JCH TH336JCHSS Crouse Hinds Arktite #APJ6485 For horsepower ratings, see switch without "CH" or CHSS suffix.
Non-Fusible / 3 Pole / 3 Wire / 600V / 50/60 Hz
60 THN3362JCH THN3362JCHSS Crouse Hinds Arktite #APJ6485 For horsepower ratings, see switch without "CH" or CHSS suffix.

4-10 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Safety Switches Section 4
Heavy Duty Stainless Steel, Type TH
Spec-Setter Safety Switches
30-600 Amperes
240, 600 Volts AC
600 Volts DC

Heavy Duty Stainless Steel, Type TH


Designed for commercial and industrial applications in
corrosive environments where safety, high performance N
and continuity of service are essential.
30-600 amps
600 Vac maximum, 600 Vdc maximum in fusible or
non-fusible units, indoor or outdoor enclosures
Fusible, Two-pole, Non-fusible, Three-pole,
Donut handle ideal for hook stick operation and accepts
Three-wire switching neutral, Three -wire, 600 Volts AC
3 padlocks in the OFF position
240 Volts AC, 250 Volts DC
Three or four welded mounting brackets
Spring reinforced fuse clips assure reliable contact for
cool operation. Suitable for Class H, K, J or R fuses.
The conductor rating is 60/75C
Short circuit ratings are UL Listed to 200,000 rms symmetrical
amps when Class J or R fuses are installed
Horsepower ratings are to UL Listed maximums
UL Listed as service entrance equipment when installed in
accordance with the National Electric Code

We offer two types of NEMA 4X enclosures:


Grade 304 Stainless Steel (order product numbers Fusible, Three-pole, Fusible, Two-pole,
with SS suffix) Three-wire, 600 Volts AC Two-wire, 600 Volts DC
NEMA Type 4X Grade 304 Stainless Steel
Helps protects against falling dirt, rain, sleet, snow, wind-
blown dust, splashing water, hose-directed water and
corrosion
Applications in harsh environments such as
food and beverage, coastal, mining
Grade 316 Stainless Steel (order product numbers
with SS316 suffix) N
NEMA Type 4X 316 Stainless Steel, Water and Dust-tight
Chemical composition that makes it more resistant to
general corrosion and pitting/crevice corrosion than 304
Stainless Steel
Higher creep, stress-to-rupture and tensile strength at Fusible, Three-pole, Non-fusible, Two-pole,
elevated temperatures than 304 Stainless Steel Four-wire switching neutral, Two-wire, 600 Volts DC
Excellent resistance to reducing acids and similar media 240 Volts AC
Provides enhanced protection over 304 Stainless Steel in
environments with salts and chemicals
Applications in extremely harsh environments such as
water/waste water, marine

All GE Heavy Duty Stainless Steel safety switches


carry the following certifications:
UL Listed and cUL Listed
(UL98 Enclosed Switches/CSA-C22.2 No. 4-04)
Federal Specification WS-865C
NEMA Enclosed Safety Switch Standard KS1-2013
Seismic Certified

Rev. 11/13 www.geindustrial.com BuyLog Catalog 4-11


Data subject to change
without notice
Safety Switches Section 4
Heavy Duty Stainless Steel, Type TH
Spec-Setter Safety Switches
30-600 Amperes
240, 600 Volts AC
600 Volts DC

NEMA Type 4X Enclosure Grade 304 Stainless Steel (see footnote below for 316 Stainless Steel offering)
Horsepower Ratings DC Horsepower Ratings
Single-Phase 240 Vac Three-Phase 240 Vac 250 Vdc
Amperage Product Number Standard Fuse Time Delay Standard Fuse Time Delay Standard Fuse
Fusible / 2 Pole / 2 Wire / 240V / 50/60 Hz
30 TH2221SS1,2 1.5 3 5
60 TH2222SS1,2 3 10 10
Fusible / 2 Pole / 3 Wire / 240V / 50/60 Hz (Neutral factory installed)
30 TH3221SS1,2 1.5 3 5
60 TH3222SS1,2 3 10 10
100 TH3223SS 1,2 7.5 15 20
N
200 TH3224SS 1,2 15 40
400 TH3225SS 50 125 50
600 TH3226SS 75 200 50
Fusible / 3 Pole / 3 Wire / 240V / 50/60 Hz
30 TH3321SS1,2 1.5 3 3 7.5 5
60 TH3322SS1,2 3 10 7.5 15 10
Fusible / 3 Pole / 4 Wire / 240V / 50/60 Hz (Neutral factory installed)
30 TH4321SS1,2 1.5 3 3 7.5 5
60 TH4322SS1,2 3 10 7.5 15 10
100 TH4323SS1,2 7.5 15 15 30 20
N
200 TH4324SS1,2 15 25 60 40
400 TH4325SS 50 125 50
600 TH4326SS 75 200 50

Horsepower Ratings DC Horsepower Ratings


Three-Phase 240 Vac Single-Phase 480 Vac Three-Phase 480 Vac Single-Phase 480 Vac Three-Phase 600 Vac 125 Vdc 250 Vdc
Std Time Std Time Std Time Std Time Std Time Std Time Std
Amperage Product Number Fuse Delay Fuse Delay Fuse Delay Fuse Delay Fuse Delay Fuse Delay Fuse
Fusible / 3 Pole / 3 Wire / 600V / 50/60 Hz
30 TH3361SS1,2,4 7.5 3 7.5 5 15 3 10 7.5 20 2 3 5
60 TH3362SS1,2,4 5 20 15 30 10 25 15 50 5 10
100 TH3363SS1,2,4 10 30 25 60 15 40 30 75 20
200 TH3364SS1,2,4 25 50 50 125 30 50 60 150 40
400 TH3365SS4 50 125 100 250 125 350 50
600 TH3366SS4 75 200 150 400 200 500 50
Non-Fusible / 3 Pole / 3 Wire / 600V / 50/60 Hz
30 THN3361SS1,2,3,4 10 7.5 20 10 30 3 5
60 THN3362SS1,2,3,4 20 20 50 25 60 5 10
100 THN3363SS1,2,4 40 30 75 40 100 20
200 THN3364SS1,2,3,4 60 50 125 50 150 40
400 THN3365SS4 125 250 350 50
600 THN3366SS4 200 400 500 50

DC Rated Heavy Duty Stainless Steel Safety Switches


DC Horsepower Ratings
125 Vdc 250 Vdc 600 Vdc
Amperage Product Number Standard Fuse Time Delay Standard Fuse Time Delay Standard Fuse Time Delay
Fusible / 2 Pole / 2 Wire / 600Vdc / 50/60 Hz
30 TH2261SSDC 2 3 5 10 15
60 TH2262SSDC 5 10 25
100 TH2263SSDC 20 25
Non-Fusible / 2 Pole / 2 Wire / 600Vdc / 50/60 Hz
30 THN2261SSDC 3 5 15
60 THN2262SSDC 5 10 25
100 THN2263SSDC 20 25
1 For switches manufactured in the USA, add BA suffix.
2 Available with Viewing Window - add W suffix
3 Available with Copper Lugs - add CL suffix
4 Available in NEMA Type 4X Enclosure Grade 316 Stainless Steel - add 316 suffix.

Selected Double Throw safety switches available in stainless steel. Refer to page 4-16.
Note: See page 4-2 for Short Circuit Ratings and page 4-20 for Lug Wire Sizes Line and Load Terminals.

4-12 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Safety Switches Section 4
Mill Duty, Type TH
Spec-Setter Safety Switches
30-600 Amperes
240, 480, 600 Volts AC N
250, 600 Volts DC

Mill Duty, Type TH Switches


Designed for mill, foundry and industrial applications where Fusible, Two-pole, 240 Volts AC - 250 Volts DC
safety, high performance and continuity of service are required
30-600 amps
600Vac maximum, 600Vdc maximum in fusible or
non-fusible units
NEMA Type 4/4X Grade 304 Stainless Steel (hose directed,
splashing and falling liquids, dust, lint, fibers, coolants,
metal filings)
NEMA Type 12 (dust, lint, fibers, coolants, metal filings
and other non-corrosive contaminants) enclosures
Donut handle ideal for hook stick operation and accepts Fusible, Three-pole, 240 Volts AC, Fusible
3 padlocks in the OFF position
Manual interlock defeat knob permits contact inspection when
switch is in the OFF position
Three or four point mounting brackets
Spring reinforced fuse clips assure reliable contact for cool
N
operation. Suitable for Class H, K, J or R fuses, where applicable.
Equipment ground lugs provided. Lugs approved for both cop-
per and aluminum wire; 60/75C rated tang lugs are field
convertible to compression (crimp) connectors
Fusible, Two-pole, 240 Volts AC; 250 Volts DC
Short circuit ratings are UL Listed to 200,000 rms symmetrical and Fusible, Two-pole, 600 Volts DC
amps when Class J or R fuses are installed (2 poles in series for 600 Vdc)
UL Listed as service entrance equipment when installed in
accordance with the National Electric Code

All GE Mill Duty safety switches


carry the following certifications:
UL Listed and cUL Listed
(UL98 Enclosed Switches/CSA-C22.2 No. 4-04)
Federal Specification WS-865C
Fusible, Three-pole, 480 and 600 Volts AC - 250 Volts DC
NEMA Enclosed Safety Switch Standard KS1-2013
Seismic Certified

Non-fusible, Two-pole, 600 Volts DC

Non-fusible, Three-pole, 480 and 600 Volts AC - 250 Volts DC

Rev. 11/13 www.geindustrial.com BuyLog Catalog 4-13


Data subject to change
without notice
Safety Switches Section 4
Mill Duty, Type TH
Spec-Setter Safety Switches
300-600 Amperes
240, 480, 600 Volts AC
250, 600 Volts DC

Mill Duty Safety Switches


Product Number2 Horsepower Rating DC Horsepower Rating
NEMA Type 4X
Amperage Grade 304 Single-Phase 240 Vac Three-Phase 240 Vac 250 Vdc
Rating NEMA Type 12 Stainless Steel Standard Fuse Time Delay Standard Fuse Time Delay Standard Fuse
Fusible / 2 Pole / 2 Wire / 240V / 50/60 Hz
30 TH2221M TH2221MSS 1.5 3 5
60 TH2222M TH2222MSS 3 10 10
100 TH2223M TH2223MSS 7.5 15 10
200 TH2224M TH2224MSS 15 40
Fusible / 3 Pole / 3 Wire / 240V / 50/60 Hz
30 TH3321M TH3321MSS 1.5 3 3 7.5 5
60 TH3322M1 TH3322MSS 3 10 7.5 15 10
100 TH3323M TH3323MSS 7.5 15 15 30 20
200 TH3324M TH3324MSS 15 25 60 40
400 TH3325M TH3325MSS 50 125 50
600 TH3326M TH3326MSS 75 200 50

Product Number2 Horsepower Rating DC Horsepower Rating


Three-Phase Single-Phase Three-Phase Single-Phase Three-Phase
NEMA Type 4X 240 Vac 480 Vac 480 Vac 600 Vac 600 Vac 125 Vdc 250 Vdc
Amperage Grade 304 Standard Time Standard Time Standard Time Standard Time Standard Time Standard Time Standard
Rating NEMA Type 12 Stainless Steel Fuse Delay Fuse Delay Fuse Delay Fuse Delay Fuse Delay Fuse Delay Fuse
Fusible / 3 Pole / 3 Wire / 600V / 50/60 Hz
30 TH3361M1 TH3361MSS 7.5 5 7.5 5 15 3 10 7.5 20 2 3 5
60 TH3362M TH3362MSS1 5 20 15 30 10 25 15 50 5 10
100 TH3363M TH3363MSS 10 30 25 60 15 40 30 75 20
200 TH3364M TH3364MSS 25 50 50 125 30 50 60 150 40
400 TH3365M TH3365MSS 50 125 100 250 125 350 50
600 TH3366M TH3366MSS 75 200 150 400 200 500 50
Non-Fusible / 3 Pole / 3 Wire / 600V / 50/60 Hz
30 THN3361M THN3361MSS1 10 7.5 20 10 30 5
60 THN3362M1 THN3362MSS 20 20 50 25 60 10
100 THN3363M THN3363MSS 40 30 75 40 100 20
200 THN3364M THN3364MSS 60 50 125 50 150 40
400 THN3365M THN3365MSS 125 250 350 50
600 THN3366M THN3366MSS 200 400 500 50

DC Rated Mill Duty Safety Switches


Product Number2 Horsepower Rating
Amperage NEMA 125 Vdc 250 Vdc 600 Vdc
Rating Type 12 Standard Fuse Time Delay Standard Fuse Time Delay Standard Fuse Time Delay
Fusible / 2 Pole / 2 Wire / 600Vdc / 50/60 Hz
30 TH2261MDC 2 3 5 10 15
60 TH2262MDC 5 10 25
100 TH2263MDC 20 25
Non-Fusible / 2 Pole / 2 Wire / 600Vdc / 50/60 Hz
30 THN2261MDC 3 5 15
60 THN2262MDC 5 10 25
100 THN2263MDC 20 25

1Available with Viewing Window - add W suffix.


2All Mill Duty switches accept neutral and auxiliary contact kits. Order from page 4-20 and 4-21.

Type TH Interrupting and Withstand Ratings Lug Wire Sizes Line and Load Terminals
Interrupting Rating Amps3 Fuse Clearing4 Wire Range Wire Range
Ampere Rating Symmetrical 600 volts AC, 3-phase (I2t x 103) Ampere Rating AWG/kcmil Copper AWG/kcmil Aluminum
30A 360 50 30A (240V) 14-8 12-8
60A 1200 200 30A (600V) 14-6 14-6
100A 1200 500 60A 14-2 14-2
200A 3,400 2,000 100A 14-1/0 12-1/0
400A 10,000 6,000 200A 2-250
600A 10,000 12,000 400A (1) 2-600 or (2) 1/0-250
3Maximum current at rated voltage that switch will interrupt three times without 600A (2) 4-600

assistance from an external device.


4Peak let-through energy for withstandability and circuit closing tests.

4-14 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Safety Switches Section 4
Double Throw Switches
Spec-Setter Safety Switches
Type TC, Type TDT
240, 480, 600 Volts AC
250 Volts DC

Non-Fused Double Throw Type TC


Fusible Double Throw Type TDT
Designed for application where safety, high performance, TC35322, Type TC Indoor Double Throw Switch
and continuity of service are required
Highly visible ON/OFF label
Bright red handle
Self-leveling three point mounting pattern
Lockable three position (ON-OFF-ON) handle
Lockable cover latch
60C and 75C conductor ratings
Quick-make, quick-break mechanisms 30-1200 amps
Use of common fuses in stacked design 600-1200 amps;
fewer fuses required and reduced enclosure size

TDT3362, Type TDT Indoor Double Throw Switch


Our Double Throw safety switches
meet the following standards:
UL Listed and cUL Listed (UL98 Enclosed Switches/CSA-C22.2
No. 4-04)
Federal Specification W-S-865C
NEMA Enclosed Switch Standard KS1 2013
Seismic Certified
Non-fusible, Three-pole, Three-wire, 240 Volts AC, 250 Volts DC

ON ON
Non-fusible, Three-pole, Three-wire, 600 Volts AC, 250 Volts DC
OFF OFF
ON ON
N

Fusible / 3 Pole / 3 Wire / Fusible / 3 Pole / 3 Wire / Non-fusible, Three-wire switching neutral, 120/240 Volts AC
Two Sources / One Load Two Loads / One Source

Non-fusible, Four-wire switching neutral, 240 Volts AC

Rev. 11/13 www.geindustrial.com BuyLog Catalog 4-15


Data subject to change
without notice
Safety Switches Section 4
Double Throw Switches
Spec-Setter Safety Switches
Type TC, Type TDT
240, 480, 600 Volts AC
250 Volts DC
Fusible
Product Number Horsepower Rating
Single-Phase Three-Phase DC Horsepower Rating
120 Vac 240 Vac 120 Vac 240 Vac 480 Vac 600 Vac 125 Vdc 250 Vdc
Amperage NEMA Type 1 NEMA Type 3R Std Time Std Time Std Time Std Time Std Time Std Time Std Time Std Time
Rating Indoor Outdoor Fuse Delay Fuse Delay Fuse Delay Fuse Delay Fuse Delay Fuse Delay Fuse Delay Fuse Delay
Fusible / 3 Pole / 3 Wire / 240V
30 TDT3321 TDT3321R 0.5 2 1.5 3 1.5 3 3 7.5 2 3 5 5
60 TDT3322 TDT3322R 1.5 3 3 10 3 7.5 7.5 15 5 10 10
100 TDT33231 TDT3323R1 7.5 15 15 30 20
200 TDT33241 TDT3324R1 15 15 25 60 40 40
400 TDT33251 TDT3325R1 50 125 50
600 TDT33263,4 TDT3326R3,4 50 125 100 250 125 350 50 50
800 TDT33273,4 TDT3327R3,4 100 125
1200 TDT33284 TDT3328R4

Product Number Horsepower Rating DC Horsepower


Single-Phase Three-Phase Rating
NEMA Type 120 Vac 240 Vac 480 Vac 600 Vac 120 Vac 240 Vac 480 Vac 600 Vac 125 Vdc 250 Vdc
Amperage NEMA Type 1 NEMA Type 4X Stainless Std Time Std Time Std Time Std Time Std Time Std Time Std Time Std Time Time Std Time
Rating Indoor 3R Outdoor Steel Fuse Delay Fuse Delay Fuse Delay Fuse Delay Fuse Delay Fuse Delay Fuse Delay Fuse Delay Delay Fuse Delay
Fusible / 3 Pole / 3 Wire / 600V
30 TDT3361 TDT3361R TDT3361SS 0.5 2 3 7.5 3 10 1.5 3 3 7.5 5 15 7.5 20 3 5
60 TDT33621 TDT3362R1 TDT3362SS1 1.5 3 3 10 5 20 10 25 3 7.5 7.5 15 15 30 15 50 5 10
100 TDT33631 TDT3363R1 TDT3363SS1 7.5 15 10 30 15 40 15 30 25 60 30 75 20
200 TDT33641 TDT3364R1 TDT3364SS1 15 15 25 50 30 50 25 25 50 125 60 150 40 40
400 TDT33652 TDT3365R2 TDT3365SS2 50 125 100 250 125 350 50 50
600 TDT33663,4 TDT3366R3,4 50 125 100 250 125 350 50
800 TDT33673,4 TDT3367R3,4 100 125 200 250 250 350
1200 TDT33684 TDT3368R4
1 Class J fuse option available when load base is moved.
2 400 Amp at 600V switches available with Class T fuse provision only.
3 Field convertible to Class T.
4 Stacked design requiring only one set of fuses (Class L).

Non-Fusible
Product Number Horsepower Rating DC Horsepower Rating Lug Wire Sizes Line and Load Terminals
NEMA
NEMA NEMA Type 4X Three-Phase
Amperage Type 1 Type 3R Stainless
Rating Indoor Outdoor Steel 240 Vac 480 Vac 600 Vac 125 Vdc 250 Vdc AWG/kcmil
Non-Fusible / 3 Pole / 3 Wire / 240V / 50/60 Hz
30 TC35321 TC35321R 2 14-8 (Cu)
60 TC35322 TC35322R 3 14-4 (Cu)
100 TC35323 TC35323R 7.5 14-1/0 (Cu)
200 TC35324 TC35324R 15 6-250 (Cu)
400 TC35325 TC35325R 30 (2) 1/0-250 (Cu) or 2-600 (Cu)
TC35326 2 50 (2) 3/0-350 (Cu) or 2-600 (Cu)
600
TC35326R 125 250 350 50 (2) 250 - (2) 500 (Cu/Al)
800 TC353274 TC35327R4 125 (3) 250 - (3) 500 (Cu/Al)
1200 TC35328 TC35328R (4) 1/0 - (4) 750 (Cu/Al)
Non-Fusible / 3 Pole / 3 Wire / 600V / 50/60 Hz
30 TC35361 TC35361R TC35361SS 10 20 30 3 5 14-2 (Cu/Al)
TC35362 TC35362R 10 10 10 14-4 (Cu)
60
TC35362SS 20 50 60 5 10 14-2 (Cu/Al)
TC35363 TC35363R 15 15 15 14-1/0 (Cu)
100
TC35363SS 40 75 100 20 14-1/0 (Cu/Al)
TC35364 TC35364R 30 30 30 6-250 (Cu)
200
TC35364SS 60 125 150 40 6-250 (Cu/Al)
TC353651,2,3 (2) 1/0-250 (Cu) or 2-600 (Cu)
400
TC35365R TC35365SS 125 250 350 50 (2) 1/0 - (2) 300 (Cu/Al) or 5 (1) 1/0 - 750 (Cu/Al)
TC353661,2 (2) 3/0-350 (Cu) or 2-600 (Cu)
600
TC35366R TC35366SS 125 250 350 (2) 250 - (2) 500 (Cu/Al)
800 TC353674 TC35367R4 TC35367SS 125 250 350 (3) 250 - (3) 500 (Cu/Al)
1200 TC35368 TC35368R (4) 1/0 - (4) 750 (Cu/Al)
1 Not UL Listed.
2 Not suitable for use as service equipment per NEC Article 702
3 No provision for auxiliary contact kit
4 Available with factory installed neutral. Add N suffix. For example: TC35327N.
5 Single barrel lug that accepts one or two cables per phase.

4-16 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Safety Switches Section 4
Double Throw Switches
Spec-Setter Safety Switches
Type TC, Type TDT
240, 480, 600 Volts AC
250 Volts DC

Type TC Accessories
Product Number Aux Contact
NEMA NEMA Type 4X
NEMA Type 3R Grade 304 1 Normally Open 2 Normally Open
Amperage Rating Type 1 Indoor Outdoor Stainless Steel Neutral Kit Ground Kit 1 Normally Closed 2 Normally Closed Control Pole
Non-Fusible / 3 Pole / 3 Wire / 240V
30 TC35321 TC35321R
TNK100 TGL1
60 TC35322 TC35322R
100 TC35323 TC35323R TNK100 TNG3 THAUXDT
200 TC35324 TC35324R TNK200 TNG3
400 TC35325 TC35325R TNK400 TGL6
TC35326 TGL6
600
TC35326R DT600NK DS16CP
800 TC35327 TC35327R1 DT800NK DS468GK DS200EK1 DS200EK2 DS16CP
1200 TC35328 TC35328R DT1200NK
Non-Fusible / 3 Pole / 3 Wire / 600V
30 TC35361 TC35361R TC35361SS DT100NK DS100GK DS200EK1 DS200EK2 DS16CP
TC35362 TC35362R TNK100 TGL1 THAUXDT
60
TC35362SS DT100NK DS100GK DS200EK1 DS200EK2 DS16CP
TC35363 TC35363R TNK100 TNG3 THAUXDT
100
TC35363SS DT100NK DS100GK DS200EK1 DS200EK2 DS16CP
TC35364 TC35364R TNK200 TNG3 THAUXDT
200
TC35364SS DT200NK DS200GK DS200EK1 DS200EK2 DS16CP
TC35365 TNK400 TGL6 THAUXDT
400
TC35365R TC35365SS DT400NK DS468GK DS200EK1 DS200EK2 DS16CP
TC35366 TGL6
600
TC35366R TC35366SS DT600NK DS16CP
800 TC35367 TC35367R1 TC35367SS DT800NK DS468GK DS200EK1 DS200EK2 DS16CP
1200 TC35368 TC35368R DT1200NK
1 Order same accessories for the "N" version.

Type TDT Accessories


Product Number Aux Contact
NEMA 1 Normally 2 Normally
NEMA NEMA NEMA NEMA Type 4X Open Open
Amperage Type 1 Type 3R Type 1 Type 3R Stainless J Fuse R Fuse T Fuse 1 Normally 2 Normally
Rating Indoor Outdoor Indoor Outdoor Steel Neutral Kit Ground Kit Adapter Kit Adapter Kit Adapter Kit Closed Closed Control Pole
30 TDT3321 TDT3321R TDT3361 TDT3361R TDT3361SS DS16FK
60 TDT3322 TDT3322R TDT3362 TDT3362R TDT3362SS DT100NK DS100GK DS26JK DS26FK
100 TDT3323 TDT3323R TDT3363 TDT3363R TDT3363SS DS36FK
200 TDT3324 TDT3324R TDT3364 TDT3364R TDT3364SS DT200NK DS200GK DS46FK DS16CP
DS200EK1 DS200EK2
400 TDT3325 TDT3325R TDT3365 TDT3365R TDT3365SS DT400NK DS468GK DT400JK3 DS56FK2 DS526TK2
600 TDT3326 TDT3326R TDT3366 TDT3366R DT600NK DS66FK
800 TDT3327 TDT3327R TDT3367 TDT3367R DT800NK DS468GK DS766TK3
1200 TDT3328 TDT3328R TDT3368 TDT3368R DT1200NK
2 240V only
3 600V only

Rev. 11/13 www.geindustrial.com BuyLog Catalog 4-17


Data subject to change
without notice
Safety Switches Section 4
Emergency Power Transfer Switches, Type TC
Spec-Setter Safety Switches

Type TC Outdoor Emergency Power Transfer Switches


Designed for residential or light commercial applications where duty is not severe
Suitable for use as service entrance equipment when installed in accordance with
National Electrical Code
Wide range of interchangeable rain-tight conduit hubs available
Plated copper current-carrying parts increase longevity and performance
Bonding strap can be used to ground neutral for service entrance applications
Positive make and break is provided by fiber loop straps between knife blade contacts
and one piece operating yoke
Lockable three-position (ON-OFF-ON) handle
Galvanized steel enclosure with drip shield TC10323R, Type TC Outdoor
60C and 75C conductor ratings Emergency Power Transfer Switch
Not quick-make, quick-break

All GE Emergency Power Transfer Switches carry the following certifications:


UL Listed and cUL Listed (UL98 Enclosed Switches/CSA-C22.2 No. 4-04)
Federal Specification WS-865C
NEMA Enclosed Safety Switch Standard KS1-2013
Seismic Certified

Emergency Power Transfer Switches


Product Number
Amperage Rating NEMA Type 3 Outdoor
Non-Fusible / 2 Pole / 3 Wire / 120/240V / 50/60Hz
100 TC10323R
200 TC10324R
Non-Fusible / 3 Pole / 4 Wire / 240V / 50/60Hz
200 TC10424R

4-18 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Safety Switches Section 4
AC Disconnects
Spec-Setter Safety Switches

Air Conditioner Disconnects


Puller or Non-Automatic Type
UL and cUL Listed
Fusible UL869

BONDED
NEUT.
Service Equipment
No fuse UL1429
Enclosed Pull-out Switch

LISTED Fusible

Steel Disconnects N3R Outdoor Enclosure

GROUND
Wire Standard

EQUIP
Type Volts Fusing Amps HP Rating Product No. Range Package

Fusible 30 3 TF30R
Pullout 240V 60 10 TF60R
TFN60R 14-3 6
Non-Fusible 60 10
TFN60RGFR1
TNA60R1 No Fuse
Non-Automatic 240V Non-Fusible 60 10
TNA60RGFR1
1These disconnects include a GFCI outlet

Plastic Disconnects N3R Outdoor Enclosure


Wire Standard
Type Volts Fusing Amps HP Rating Product No. Range Package
Non-automatic
Fusible 30 3 TPF30R
Pullout 240V 60 10 TPF60R 14-3 6
Non-Fusible 60 10 TPN60R12
Non-Automatic 240V Non-Fusible 60 10 TPNA60R12
2Devices do not have removable closing cap.

TF30R, Steel Enclosure TNA60RGFR, Steel Enclosure TPF30R, Plastic Enclosure

TF60R, Steel Enclosure TFN60RGFR, Steel Enclosure TPN60R1, Plastic Enclosure

TFN60R, Steel Enclosure TPF60R, Thermoplastic Enclosure

Rev. 11/13 www.geindustrial.com BuyLog Catalog 4-19


Data subject to change
without notice
Safety Switches Section 4
Accessories: NEMA Type 1 and 3R Enclosures
Spec-Setter Safety Switches
30-600 Amperes: TG and TH
800-1200 Amperes: TC (Single Throw Fuse Only)

Equipment Ground Kits


Wire Range Wire Range
Ampere Rating Product Number AWG/kcmil Copper AWG/kcmil Aluminum Std. Pkg
30A
TGL1 (4) 14-8, (3) 14-4 (4) 12-8, (3) 6-4 20
60A
100A
TNG3 (3) 10-1/0 (3) 10-1/0 1
200A
400A
TGL6 (3) 2-250 (3) 2-250 1 TGL1 Equipment Ground Kit
600A

Neutral Kit Insulated, Groundable and Bondable


System Fusible/Non- Wire Range Wire Range
Ampere Rating Product Number Voltage Fusible AWG/kcmil Copper AWG/kcmil Aluminum
30A TNI21 240Vac Either 14-8 12-8
30A TNI621 600Vac Either 12-2 12-2
30A TNI621 600Vac Non-Fusible 12-2 12-2
60A TNIA62 600Vac Fusible 12-2 12-2
100A TNI631 600Vac Non-Fusible 10-1/0 10-1/0
100A TNIA63 600Vac Fusible 10-1/0 10-1/0
200A TNIA64 600Vac Either 2-250 2-250
400A TNI65 Either (1) 2-600 or (2) 1/0-250 (1) 2-600 or (2) 1/0-250
400A TNI65A Either (1) 350-800 (1) 350-800 TNG3 Equipment Ground Kit
240Vac or
600A TNI66 Either (2) 4-500 (2) 4-500
600Vac
800A TNI672 Either (3) 2-600 or (6) 1/0-250 (3) 2-600 or (6) 1/0-250
1200A TNI68A2 Either (4) 3/0-800 (4) 3/0-800

Switching Neutral: Order standard switch of required number of poles and use dummy fuse in neutral pole.
1 Not suitable for type TG switches.
2 Not suitable for type TC Double Throw or TC Single Throw Non-Fusible

Note: All accessories are available in standard package of 1 unless otherwise noted.

Lug Wire Sizes Line and Load Terminals


Ampere Rating Wire Range AWG/kcmil Copper Wire Range AWG/kcmil Aluminum
30A (250V) 14-8 12-8
30A (600V) 12-2 12-2 TNIA64 Neutral Kit Insulated,
60A 12-2 12-2 Groundable and Bondable
100A 10-1/0 10-1/0
200A 2-250 2-250
400A (1) 2-600 or (2) 1/0-250 (1) 2-600 or (2) 1/0-250
600A (2) 4-500 (2) 4-500
800A (3) 2-600 or (6) 1/0-250 (3) 2-600 or (6) 1/0-250
1200A (4) 3/0-800 (4) 3/0-800

4-20 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Safety Switches Section 4
Accessories: NEMA Type 1 and 3R Enclosures
Spec-Setter Safety Switches
30-600 Amperes: TH

Auxiliary Contact Kits


Auxiliary contacts designed to open before switch blades. UL Listed for field installation.
Product number listed is for field installed kit.
Ampere Rating No. of Poles Contacts Contact Ratings Product Number
10A, 125/250Vac
2 THAUX21D
30A DPDT 0.30A, 125Vdc
3
0.15A, 250Vdc
15A, 600Vac
2
30A SPDT 0.50A, 125Vdc THAUX61S
3
0.25A, 250Vdc
60A 15A, 600Vac
100A
2
DPDT 0.50A, 125Vdc THAUX64D THAUX21D
3
200A 0.25A, 250Vdc
15A, 600Vac
400A 2
DPDT 0.50A, 125Vdc THAUX66D
600A 3
0.25A, 250Vdc
30A 15A, 600Vac
60A 6 DPDT 0.50A, 125Vdc THAUX66D
100A 0.25A, 250Vdc
15A, 600Vac
200A 6 DPDT 0.50A, 125Vdc THAUX66D2
0.25A, 250Vdc

Contact Pilot Duty Ratings - 600 Volt Kits THAUX61S


Inrush Current AC DC (Resistive)
Volts N.C N.O. Break Normal Current Volts Break Normal Current
115 30 15 15 125 0.5
230 30 15 25 0.25
460 30 15 15
575 15 15 2

Semidust-tight Door Gasket Kits


Types TH Indoor, TG and TH Outdoor Switches.
Product Number listed is for field mounted kit. THAUX64D
Ampere Rating Product Number
30A
60A THG106
100A
200A THG107
400A
THG108
600A

THAUX66D

Rev. 11/13 www.geindustrial.com BuyLog Catalog 4-21


Data subject to change
without notice
Safety Switches Section 4
Accessories: NEMA Type 4/4X, 12 and Mill Duty Enclosures
Spec-Setter Safety Switches
30-600 Amperes: TH

Lug Wire Sizes


Line and Load Terminals
Factory Installed Field Installed Crimp Lugs (see table on page 4-23)
Wire Range Wire Range Wire Range Wire Range
Ampere Rating AWG/kcmil Copper AWG/kcmil Aluminum AWG/kcmil Copper AWG/kcmil Aluminum
30A (250V) 14-8 12-8
30A (600V) 14-6 14-6 14-8
60A 14-2 14-2 8-4
100A 14-1/0 12-1/0 6-1/0 6-2/0
200A 6-250 1/0-250
400A (1) 2-600 or (2) 1/0-250 (2) 300-600 or (1) 750 (2) 250-600 or (1) 750
600A (2) 4-600 (2) 300-600 or (1) 750 (2) 250-600 or (1) 750

Equipment Ground TerminalsTwo lugs supplied per switch, provision for one additional lug.
Factory Installed Field Installed Crimp Lugs (See table on page 4-23)
Switch Ampere Rating Copper Aluminum Copper Aluminum
30A 14-6 14-6 14-8
60A 14-6 14-6 14-8
100A 14-4 14-4 8 6
200A 14-4 14-4 6 4
400A 14-1/0 14-1/0 3-2 1
600A 14-2/0 14-2/0 1 2/0

Auxiliary Contact Kits


Auxiliary contacts designed to open before switch blades. UL Listed for field installation. Product number listed is for field installed kit.
For Auxiliary Contact Kits, see page 4-21.

Optional Copper Lug Neutrals


Lug Wire Size,
Ampere Rating Fusible AWG/kcmil, Cu Only Product Number
30A-60A No 14-2 TNIJA62CL

Neutral Kit Insulated, Groundable and Bondable


Lug Wire Size AWG/ kcmil Lug Wire Size AWG/ Lug Wire Size AWG/ kcmil Lug Wire Size AWG/ kcmil
Factory Installed kcmil Factory Installed Field Installed Crimp Lugs Field Installed Crimp Lugs
Ampere Rating Product Number System Voltage Fusible/Non-fusible Aluminum Copper Copper Aluminum
30A TNI21 240Vac Fusible 12-8 14-8 - -
30A TNIJ61 600Vac1 Either 14-6 14-6 14-8 -
60A TNIJ62 600Vac2 Fusible 14-2 14-2 8-4 -
60A TNIJ62 240Vac2 Fusible 14-2 14-2 8-4 -
60A TNIJ62 600Vac Fusible 14-2 14-2 8-4 -
60A TNIJA62 600Vac2 Non-fusible 14-2 14-2 8-4 -
60A TNIJA62 600Vac Non-fusible 14-2 14-2 8-4 -
100A TNIJ63 Either 12-1/0 14-1/0 6-1/0 6-2/0
240Vac or
200A TNIJ64 Either 6-250 6-250 1/0-250 1/0-250
600Vac
400-600A TNIJ66 Either (2) 4-600 (2) 4-600 (2) 300-600 or (1) 750 (2) 250-600 or (1) 750
1 Type 4, 4X, 12
2 Mill duty type

4-22 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Safety Switches Section 4
Accessories: NEMA Type 4/4X, 12 and Mill Duty Enclosures
Spec-Setter Safety Switches
30-600 Amperes: TH

Crimp-type Connectors - Field Replaceable1


Line and Load Terminals
Thomas and Betts Product Number Burndy Product Number
Switch Ampere Rating Lug Wire Size AWG/kcmil Copper Aluminum Copper Aluminum
30A 14-12 - - YAV12 G2 -
30A 12-10 - - YAV10 -
30A 8 54104 - YAV8C-L -
60A 8 54130 - YAV8C-L1 -
60A 6 54105 - YAV6C-L -
60A 4 54106 - YAV4CLY1 -
100A 6 54105 60107 - -
100A 4 54106 60112 - -
100A 2 54017 60116 - -
100A 1 54108 60122 - -
100A 1/0 - - YA25-L YA25A1
200A 1/0 54153 60129 - -
200A 1/0 54109 60130 - -
200A 2/0 54158 60135 - -
200A 2/0 54110 60136 - -
200A 3/0 54163 60141 - -
200A 3/0 54111 60142 - -
200A 4/0 54168 60147 - -
200A 4/0 54112 60148 - -
200A 250 54173 60153 - -
200A 250 54174 60154 - -
400A and 600A 250 - 60156 - -
400A and 600A 300 54114 60162 - -
400A and 600A 350 54115 60165 - -
400A and 600A 400 54116 - - -
400A and 600A 500 54118 60171 - -
400A and 600A 600 54120 60174 - -
400A and 600A 750 54123 60178 - -

Equipment Ground Terminals (provision for three per switch)


Thomas and Betts Product Number Burndy Product Number
Switch Ampere Rating Lug Wire Size AWG/kcmil Copper Aluminum Copper Aluminum
30A 10 - - - -
30A 8 54104 - YAV8C-L -
60A 8 54104 - YAV8C-L -
100A 8 54105 - - -
100A 6 - 60106 - -
200A 6 54105 - - -
200A 4 - 60112 - -
400A 3-2 54107 - - -
400A 1 - 60122 - -
600A 1 54108 - - -
600A 2/0 - 60134 - -
1 Not furnished with switches.

Rev. 11/13 www.geindustrial.com BuyLog Catalog 4-23


Data subject to change
without notice
Safety Switches Section 4
Accessories
Type TG, TH
Spec-Setter Safety Switches

Class R Fusing Kit Field Installable, General Duty, Type TG, UL Listed
When specifications permit only Class R fuses to be used, these kits may be installed in
the safety switch to deter fuses other than Class R from being installed.
3060A = Fuse Clips
100200A = Rejection Pins
One kit required per two pole or three pole switch

Series Prefix Ampere Rating Enclosure Type Product Number


30A NEMA Type 1, 3R TGRK12
TG
60A NEMA Type 1, 3R TGRK22 TGRK22 Class R Rejection Kit
100A NEMA Type 1, 3R TGRK42
200A NEMA Type 1, 3R TGRK42

Class J Fuse Field Conversion Kit, Heavy Duty, Type TH, UL Listed
TH switches, 30-400 amperes, 600 volt and 100-400 amperes, 240 volt, may be adapted
to accept Class J fuses without a kit by moving the load-block toward the switch base
and remounting.

Series Prefix Ampere Rating System Voltage Product Number


TH 600A 240Vac 600Vac THJ6

Class R Fusing Kit Field Installable, Heavy Duty, Type TH, UL Listed
When specifications permit only Class R fuses to be used, these kits may be installed in
the safety switch to deter fuses other than Class R from being installed.
3060A = Fuse Clips
100200A = Rejection Pins
One kit required per two pole or three pole switch

Series Prefix Ampere Rating System Voltage Enclosure Type Product Number
30A 240Vac NEMA Type 1, 3R, 4/4X, 12 TRK12B
30A 600Vac NEMA Type 1, 3R TRK16B
30A 600Vac NEMA Type 4/4X, 12 TRK16SA TRK46A Class R Rejection Kit
60A 240Vac NEMA Type 1, 3R, 4/4X, 12 TRK22A
60A 600Vac NEMA Type 1, 3R, 4/4X, 12 TRK26A
TH
100A 240Vac 600Vac NEMA Type 1, 3R TRK46A
100A 240Vac 600Vac NEMA Type 4/4X, 12 TPBRK36A
200A 240Vac 600Vac NEMA Type 1, 3R, 4/4X, 12 TRK46A
400A 240Vac 600Vac NEMA Type 1, 3R, 4/4X, 12 TRK56A
600A 240Vac 600Vac NEMA Type 1, 3R, 4/4X, 12 TRK66A

4-24 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Page Updated 01 / 2017

Safety Switches Section 4


Accessories
Spec-Setter Safety Switches

Universal Raintight Aluminum Hubs


For outdoor enclosures that have removable closing caps.

Nominal Conduit Diameter (in.) Product Number


3/4 TC75
1 TC100
1 1/4 TC125
1 1/2 TC150
2 TC200
2 1/2 TC250

TC200 Universal Raintight Hub


Closing Cap for Universal Raintight Aluminum Hub
Product Number

TCCP

Replacement Red Handle Grip for HD Switches


Product Number

THGRIP

Replacement Handles for HD Switches


Amps Min. Amps Max. Max. Volts Steel Type Description Product Number
30A 30A 240V Steel Handle and Pouch THRPLHDL1
30A 30A 600V Steel Handle and Pouch THRPLHDL2
60A 200A 600V Steel Handle and Pouch THRPLHDL3
30A 200A 600V Stainless Handle and Pouch THRPLHDL4
400A 600A 600V Steel Handle and Pouch THRPLHDL6
400A 600A 600V Stainless Handle and Pouch THRPLHDL7

Rev. 11/13 www.geindustrial.com BuyLog Catalog 4-25


Data subject to change
without notice
Safety Switches Section 4
Enclosure Dimensions
Spec-Setter Safety Switches
TG and TH, NEMA Type 1 and 3R Enclosures

General Duty, NEMA Type 1 Approximate Dimensions in inches


Product Dimension Dimension Dimension W2 Dimension Dimension D2 Weight KO Figure D2
W2
Number H W (Box) (W/ Handle) D (Box) (W/ Handle) (lbs) Drawing # Number D

TG3221 10.3 6.4 6.9 3.3 6.3 5 10103091SH104 1


TG3222 13.8 8.4 8.9 4.0 7.9 10 10103091SH104 15
TG3223 21.3 9.4 10.6 4.9 9.9 16 10103091SH108 3
TG3224 29.1 13.4 14.6 5.2 9.3 30 10103091SH108 4
H
TG3224B 29.1 13.4 14.6 5.2 9.3 30 10103091SH108 4
TG3225 49.4 21.6 22.8 8.7 14.6 102 10103091SH116 5
TG3225B 49.4 21.6 22.8 8.7 14.6 102 10103091SH116 5
TG3226 49.9 22.9 24.1 9.0 14.8 107 10103091SH116 6
TG3325 49.4 21.6 22.8 8.7 14.6 107 10103091SH116 7
TG3325B 49.4 21.6 22.8 8.7 14.6 107 10103091SH116 7
W
TG3326 49.9 22.9 24.1 9.0 14.8 124 10103091SH116 6
TG3326B 49.9 22.9 24.1 9.0 14.8 124 10103091SH116 6
General Duty NEMA Type 1
TG4321 10.3 6.4 6.9 3.3 6.3 5 10103091SH104 1
TG4322 13.8 8.4 8.9 4.0 7.9 10 10103091SH104 15
TG4323 21.3 9.4 10.6 4.9 9.9 17 10103091SH108 3
TG4324 29.1 13.4 14.6 5.2 9.3 32 10103091SH108 4
TG4324B 29.1 13.4 14.6 5.2 9.3 32 10103091SH108 4
TG4325 49.4 21.6 22.8 8.7 14.6 111 10103091SH116 7
TG4325B 49.4 21.6 22.8 8.7 14.6 111 10103091SH116 7
TG4326 49.9 22.9 24.1 9.0 14.8 126 10103091SH116 6
TG4326B 49.9 22.9 24.1 9.0 14.8 126 10103091SH116 6
TGN3321 10.3 6.4 6.9 3.3 6.3 5 10103091SH104 1
TGN3322 13.8 8.4 8.9 4.0 7.9 10 10103091SH104 15
TGN3323 21.3 9.4 10.6 4.9 9.9 16 10103091SH108 3
TGN3324 29.1 13.4 14.6 5.2 9.3 30 10103091SH108 4
TGN3324B 29.1 13.4 14.6 5.2 9.3 30 10103091SH108 4
TGN3325 49.4 21.6 22.8 8.7 14.6 118 10103091SH116 7
TGN3325B 49.4 21.6 22.8 8.7 14.6 118 10103091SH116 7
TGN3326 49.9 22.9 24.1 9.0 14.8 120 10103091SH116 6
TGN3326B 49.9 22.9 24.1 9.0 14.8 120 10103091SH116 6

Heavy Duty, NEMA Type 1 Approximate Dimensions in inches


D2
Product Dimension Dimension Dimension W2 Dimension Dimension D2 Weight KO Figure W2 D
Number H W (Box) (W/ Handle) D (Box) (W/ Handle) (lbs) Drawing # Number
TH2261DC 12.6 8.3 9.5 4.0 7.6 11 10103091SH102 15
TH2262DC 21.3 9.1 9.4 5.0 8.6 18 10103091SH102 3
TH2263DC 22.3 9.3 10.1 4.8 9.8 19 10103091SH105 14
TH3221 10.3 6.3 7.1 3.3 6.1 6 10103091SH102 1
H
TH3222 17.6 9.4 10.1 5.0 9.0 15 10103091SH102 3
TH3223 21.3 9.3 10.1 4.8 9.8 17 10103091SH105 3
TH3224 31.5 13.3 14.1 5.1 10.5 33 10103091SH105 4
TH3224B 31.5 13.3 14.1 5.1 10.5 33 10103091SH105 4
TH3224C 31.5 13.3 14.1 5.1 10.5 33 10103091SH105 4
TH3225 50.9 22.9 23.6 8.3 14.4 120 10103091SH112 6
W
TH3225B 50.9 22.9 23.6 8.3 14.4 120 10103091SH112 6
TH3225C 50.9 22.9 23.6 8.3 14.4 135 10103091SH112 6
Heavy Duty NEMA Type 1
TH3226 50.9 22.9 23.6 8.3 14.4 134 10103091SH112 6
TH3226B 50.9 22.9 23.6 8.3 14.4 134 10103091SH112 6
TH3226C 50.9 22.9 23.6 8.3 14.4 134 10103091SH112 6
TH3267C 61.5 40.8 44.0 11.9 18.5 500 10103091SH112 6
TH3268C 76.6 46.6 45.8 12.9 18.9 480 10103091SH112 6
TH3325 50.9 22.9 23.6 8.3 14.4 126 10103091SH112 6
TH3325B 50.9 22.9 23.6 8.3 14.4 126 10103091SH112 6
TH3326 50.9 22.9 23.6 8.3 14.4 138 10103091SH112 6
TH3326B 50.9 22.9 23.6 8.3 14.4 138 10103091SH112 6
TH3361 12.6 8.3 9.5 4.0 7.6 11 10103091SH102 15
TH3362 21.3 9.1 9.4 5.0 8.6 18 10103091SH102 3
TH3363 22.3 9.3 10.1 4.8 9.8 18 10103091SH105 14
TH3364 31.5 13.3 14.1 5.1 10.5 33 10103091SH105 4
TH3364B 31.5 13.3 14.1 5.1 10.5 34 10103091SH105 4
TH3365 53.9 22.9 23.6 8.3 14.4 126 10103091SH112 6
TH3365B 53.9 22.9 23.6 8.3 14.4 122 10103091SH112 6
TH3366 53.9 22.9 23.6 8.3 14.4 139 10103091SH112 6
TH3366B 53.9 22.9 23.6 8.3 14.4 139 10103091SH112 6
TH4321 10.3 6.3 7.1 3.3 6.1 6 10103091SH102 1
TH4322 17.6 9.4 10.1 5.0 9.0 16 10103091SH102 3
TH4323 21.3 9.3 10.1 4.8 9.8 17 10103091SH105 3
TH4324 31.5 13.3 14.1 5.1 10.5 33 10103091SH105 4
TH4324B 31.5 13.3 14.1 5.1 10.5 32 10103091SH105 4
TH4324C 31.5 13.3 14.1 5.1 10.5 32 10103091SH105 4
(table continued on next page)

4-26 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Safety Switches Section 4
Enclosure Dimensions
Spec-Setter Safety Switches
TG and TH, NEMA Type 1 and 3R Enclosures

Heavy Duty, NEMA Type 1 (Cont.) Approximate Dimensions in inches


D2
Product Dimension Dimension Dimension W2 Dimension Dimension D2 Weight KO Figure W2 D
Number H W (Box) (W/ Handle) D (Box) (W/ Handle) (lbs) Drawing # Number
TH4325 50.9 22.9 23.6 8.3 14.4 128 10103091SH112 6
TH4325B 50.9 22.9 23.6 8.3 14.4 128 10103091SH112 6
TH4325C 50.9 22.9 23.6 8.3 14.4 128 10103091SH112 6
TH4326 50.9 22.9 23.6 8.3 14.4 139 10103091SH112 6 H
TH4326B 50.9 22.9 23.6 8.3 14.4 139 10103091SH112 6
TH4326C 50.9 22.9 23.6 8.3 14.4 80 10103091SH112 6
TH4364C 31.5 13.3 14.1 5.1 10.5 32 10103091SH105 4
TH4365C 53.9 22.9 23.6 8.3 14.4 132 10103091SH112 6
TH4366C 53.9 22.9 23.6 8.3 14.4 132 10103091SH112 6
TH4367C 61.5 40.8 44.0 11.9 18.5 331 10103091SH118 No KO
W
TH4368C 76.6 46.6 45.8 12.9 18.9 377 10103091SH118 No KO
TH6621 14.4 18.7 19.9 5.9 12.3 33 10103091SH121 20 Heavy Duty NEMA Type 1
TH6622 23.9 18.7 19.9 5.9 12.7 40 10103091SH121 20
TH6623 23.9 18.7 19.8 5.8 10.9 45 10103091SH127 20
TH6624 35.1 26.0 26.8 5.7 10.4 45 10103091SH127 20
TH6661 14.4 18.7 19.9 5.9 12.3 33 10103091SH121 20
TH6662 23.9 18.7 19.9 5.9 12.7 46 10103091SH121 20
TH6663 23.9 18.7 19.8 5.8 10.9 46 10103091SH127 20
TH6664 35.1 26.0 26.8 5.7 10.4 45 10103091SH127 20
THN2261DC 10.3 8.3 9.3 4.0 7.7 9 10103091SH102 15
THN2262DC 17.6 9.4 10.1 5.0 8.1 15 10103091SH102 3
THN2263DC 17.6 9.3 10.1 4.8 9.8 23 10103091-SH105 3
THN3321 10.3 6.3 7.1 3.3 6.1 6 10103091SH102 1
THN3361 10.3 8.3 9.3 4.0 7.7 9 10103091SH102 15
THN3361CL 10.3 8.3 9.3 4.0 7.7 9 10103091SH102 15
THN3362 17.6 9.4 10.1 5.0 9.0 15 10103091SH102 3
THN3362CL 17.6 9.4 10.1 5.0 9.0 15 10103091SH102 3
THN3363 17.6 9.3 10.1 4.8 9.8 15 10103091SH105 3
THN3363CL 17.6 9.3 10.1 4.8 9.8 15 10103091SH105 3
THN3364 31.5 13.3 14.1 5.1 10.5 32 10103091SH105 4
THN3364B 31.5 13.3 14.1 5.1 10.5 32 10103091SH105 4
THN3364CL 31.5 13.3 14.1 5.1 10.5 33 10103091SH105 4
THN3365 42.6 22.9 23.6 8.3 14.4 108 10103091SH112 6
THN3365B 42.6 22.9 23.6 8.3 14.4 108 10103091SH112 6
THN3366 42.6 22.9 23.6 8.3 14.4 109 10103091SH112 6
THN3366B 42.6 22.9 23.6 8.3 14.4 109 10103091SH112 6
THN3366CL 42.6 22.9 23.6 8.3 14.4 109 10103091SH112 6
THN6661 14.4 18.7 19.9 5.9 12.3 33 10103091SH121 20
THN6662 23.9 18.7 19.9 5.9 12.7 46 10103091SH121 20
THN6663 23.9 18.7 19.8 5.8 10.9 46 10103091SH127 20
D2
THN6664 35.1 26.0 26.8 5.7 10.4 47 10103091SH127 20 W2 D

General Duty, NEMA Type 3R Approximate Dimensions in inches


Product Dimension Dimension Dimension W2 Dimension Dimension D2 Weight KO Figure
H
Number H W (Box) (W/ Handle) D (Box) (W/ Handle) (lbs) Drawing # Number
TG3221R 9.8 6.4 6.8 3.3 6.3 6 10103091SH103 8
TG3222R 13.7 8.4 8.8 3.9 7.9 11 10103091SH103 19
TG3223R 21.1 9.3 10.3 5.0 9.1 17 10103091SH107 10
TG3224R 29.3 13.4 13.7 5.4 9.9 31 10103091SH183 11
TG3225R 49.7 21.7 22.4 8.9 14.7 110 10103091SH141 12 W
TG3226R 50.1 23.0 23.8 9.4 15.1 119 10103091SH141 13
TG3325R 49.7 21.7 22.4 8.9 14.7 109 10103091SH141 12 General Duty NEMA Type 3R
TG3326R 50.1 23.0 23.8 9.4 15.1 124 10103091SH141 13
TG4321R 9.8 6.4 6.8 3.3 6.3 6 10103091SH103 8
TG4322R 13.7 8.4 8.8 3.9 7.9 11 10103091SH103 19 D2
TG4323R 21.1 9.3 10.3 5.0 9.1 17 10103091SH107 10 D
TG4324R 29.3 13.4 13.7 5.4 9.9 32 10103091SH183 11 W2
TGN3321R 9.8 6.4 6.8 3.3 6.3 6 10103091SH103 8
TGN3322R 13.7 8.4 8.8 3.9 7.9 10 10103091SH103 19
TGN3323R 15.6 9.3 10.3 5.0 9.1 13 10103091SH107 10
TGN3324R 29.3 13.4 13.7 5.4 9.9 31 10103091SH183 11
H

General Duty NEMA Type 3R


200-600A Side Swing

Rev. 11/13 www.geindustrial.com BuyLog Catalog 4-27


Data subject to change
without notice
Safety Switches Section 4
Enclosure Dimensions
Spec-Setter Safety Switches
TH and TC, NEMA Type 1 and 3R Enclosures

Heavy Duty, NEMA Type 3R Approximate Dimensions in inches


D2
Product Dimension Dimension Dimension W2 Dimension Dimension D2 Weight KO Figure W2 D
Number H W (Box) (W/ Handle) D (Box) (W/ Handle) (lbs) Drawing # Number
TH2261RDC 13.1 8.2 8.9 4.0 7.9 11 10103091SH101 19
TH2262RDC 22.0 9.2 9.7 4.8 7.9 19 10103091SH101 10
TH2263RDC 22.1 9.3 10.2 4.9 9.8 20 10103091SH106 10
TH3221R 10.5 6.2 6.6 3.1 7.7 7 10103091SH101 8
H
TH3222R 17.2 9.2 9.7 4.8 7.9 16 10103091SH101 10
TH3223R 22.1 9.3 10.2 4.9 9.8 18 10103091SH106 10
TH3224R 31.7 13.4 14.3 5.4 9.5 34 10103091SH182 11
TH3224RC 31.7 13.4 14.3 5.4 9.5 34 10103091SH182 11
TH3225R 49.5 23.0 24.1 8.5 13.9 128 10103091SH140 18
TH3225RC 49.5 23.0 24.1 8.5 13.9 128 10103091SH140 18
W
TH3226R 53.5 23.0 24.1 8.5 13.9 134 10103091SH140 18
TH3226RC 53.5 23.0 24.1 8.5 13.9 134 10103091SH140 18 Heavy Duty NEMA Type 3R
TH3267RC 61.5 40.8 44.0 11.9 18.5 500 10103091SH118 No KO
TH3268RC 76.6 46.6 45.8 12.9 18.9 490 10103091SH118 No KO
TH3325R 49.5 23.0 24.1 8.5 13.9 127 10103091SH140 18
D2
TH3326R 53.5 23.0 24.1 8.5 13.9 139 10103091SH140 18
D
TH3361R 13.1 8.2 8.9 4.0 7.9 11 10103091SH101 19 W2
TH3361RF 14.9 10.3 10.9 3.9 8.0 11 10103091SH133 No KO
TH3361RF2 22.4 13.3 14.0 4.8 9.9 23 10103091SH134 No KO
TH3362R 22.0 9.2 9.7 4.8 7.9 18 10103091SH101 10
TH3362RF 22.4 13.3 14.0 4.8 9.9 18 10103091SH134 No KO
TH3363R 22.1 9.3 10.2 4.9 9.8 19 10103091SH106 10
TH3364R 31.7 13.4 14.3 5.4 9.5 33 10103091SH182 11 H
TH3365R 53.5 23.0 24.1 8.5 13.9 132 10103091SH140 18
TH3366R 53.5 23.0 24.1 8.5 13.9 136 10103091SH140 18
TH4321R 10.5 6.2 6.6 3.1 7.7 7 10103091SH101 8
TH4322R 17.2 9.2 9.7 4.8 7.9 16 10103091SH101 10
TH4323R 22.1 9.3 10.2 4.9 9.8 18 10103091SH106 10
TH4324R 31.7 13.4 14.3 5.4 9.5 34 10103091SH182 11 W
TH4324RC 31.7 13.4 14.3 5.4 9.5 34 10103091SH182 11 Heavy Duty NEMA Type 3R
TH4325RC 49.5 23.0 24.1 8.5 13.9 125 10103091SH140 No KO
TH4326RC 53.5 23.0 24.1 8.5 13.9 130 10103091SH140 No KO 200-600A Side Swing
TH4364RC 31.7 13.4 14.3 5.4 9.5 32 10103091SH182 No KO
TH4365RC 49.5 23.0 24.1 8.5 13.9 130 10103091SH140 No KO
TH4366RC 53.5 23.0 24.1 8.5 13.9 132 10103091SH140 No KO
TH4367RC 61.5 40.8 44.0 11.9 18.5 510 10103091SH118 No KO
TH4368RC 76.6 46.6 45.8 12.9 18.9 750 10103091SH118 No KO
THN2261RDC 13.1 8.2 8.9 4.0 7.9 11 10103091SH101 19
THN2262RDC 17.2 9.2 9.7 4.8 7.9 16 10103091SH101 10
THN2263RDC 17.3 9.3 10.2 4.9 9.8 16 10103091SH106 10
THN3361R 13.1 8.2 8.9 4.0 7.9 11 10103091SH101 19
THN3361RF 14.9 10.3 10.9 3.9 8.0 13 10103091SH133 19
THN3361RF2 22.4 13.3 14.0 4.8 9.9 22 10103091SH134 17
THN3362R 17.2 9.2 9.7 4.8 7.9 15 10103091SH101 10
THN3362RF 22.4 13.3 14.0 4.8 9.9 22 10103091SH134 17
THN3363R 17.3 9.3 10.2 4.9 9.8 15 10103091SH106 10
THN3364R 31.7 13.4 14.3 5.4 9.5 33 10103091SH182 11
THN3365R 49.5 23.0 24.1 8.5 13.9 122 10103091SH140 18
THN3366R 53.5 23.0 24.1 8.5 13.9 130 10103091SH140 18

800-1200A NEMA Type 1 and 3R Approximate Dimensions in inches


Product Dimension Dimension Dimension W2 Dimension Dimension D2 Weight KO Figure
Number H W (Box) (W/ Handle) D (Box) (W/ Handle) (lbs) Drawing # Number
TC36367 52.0 31.3 34.5 10.5 18.5 317 10103091SH118
TC36368 65.0 36.5 39.7 11.8 18.9 331 10103091SH118
TC72267 61.5 40.8 44.0 11.9 18.5 377 10103091SH118
TC72267R 61.5 40.8 44.0 11.9 18.5 480 10103091SH118
TC72268 76.6 46.6 45.8 12.9 18.9 391 10103091SH118 No KO
TC72268R 76.6 46.6 45.8 12.9 18.9 575 10103091SH118
TC72367 61.5 40.8 44.0 11.9 18.5 377 10103091SH118
TC72367R 61.5 40.8 44.0 11.9 18.5 480 10103091SH118
TC72368 76.6 46.6 45.8 12.9 18.9 480 10103091SH118
TC72368R 76.6 46.6 45.8 12.9 18.9 490 10103091SH118

4-28 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Safety Switches Section 4
Enclosure Dimensions
Spec-Setter Safety Switches
TH and THN, NEMA Type 4/4X Enclosures

Heavy Duty, NEMA Type 4/4X (316 Stainless) Approximate Dimensions in inches D2
Product Dimension Dimension Dimension W2 Dimension Dimension D2 Weight KO Figure D
W2
Number H W (Box) (W/ Handle) D (Box) (W/ Handle) (lbs) Drawing # Number
TH3361SS316 13.3 9.4 10.1 4.9 9.4 18 10103091SH109
TH3361SS316-BA 13.3 9.4 10.1 4.9 9.4 18 10103091SH109
TH3362SS316 19.3 9.4 10.1 5.2 9.6 23 10103091SH109
TH3362SS316-BA 19.3 9.4 10.1 5.2 9.6 23 10103091SH109
H
TH3363SS316 25.4 13.4 14.3 5.2 9.6 36 10103091SH113
TH3363SS316-BA 25.4 13.4 14.3 5.2 9.6 36 10103091SH113
TH3364SS316 35.1 14.5 15.5 5.2 9.6 49 10103091SH113
TH3364SS316-BA 35.1 14.5 15.5 5.2 9.6 49 10103091SH113
THN3361SS316 11.3 9.4 10.1 4.9 9.4 16 10103091SH109 No KO
THN3361SS316-BA 11.3 9.4 10.1 4.9 9.4 9 10103091SH109
W
THN3362SS316 13.3 9.4 10.1 5.2 9.6 22 10103091SH109
THN3362SS316-BA 13.3 9.4 10.1 5.2 9.6 22 10103091SH109
Heavy Duty NEMA Type 4/4X
THN3363SS316 25.4 13.4 14.3 5.2 9.6 36 10103091SH113
THN3363SS316-BA 25.4 13.4 14.3 5.2 9.6 36 10103091SH113
THN3364SS316 35.1 14.5 15.5 5.2 9.6 50 10103091SH113
THN3364SS316-BA 35.1 14.5 15.5 5.2 9.6 50 10103091SH113
THN3365SS316 59.5 24.6 25.6 8.4 13.8 239 10103091SH119
THN3366SS316 59.5 24.6 25.6 8.4 13.8 239 10103091SH119

Heavy Duty, NEMA Type 4/4X Water/Dust-tight Approximate Dimensions in inches


D2
Product Dimension Dimension Dimension W2 Dimension Dimension D2 Weight KO Figure
Number H W (Box) (W/ Handle) D (Box) (W/ Handle) (lbs) Drawing # Number D
W2
TH2221MSS 11.2 7.4 8.1 4.7 9.8 14 10103091SH123
TH2221SS 11.3 7.4 8.1 5.4 10.0 12 10103091SH110
TH2221SS-BA 11.3 7.4 8.1 4.9 9.4 12 10103091SH109
TH2221SSW 11.3 7.4 8.1 5.4 10.0 12 10103091SH110
TH2222MSS 19.3 9.4 14.1 5.0 10.1 20 10103091SH123
H
TH2222SS 19.3 9.4 10.1 5.2 9.6 21 10103091SH109
TH2222SS-BA 19.3 9.4 10.1 5.2 9.6 21 10103091SH109
TH2222SSW 19.3 9.4 10.1 5.2 9.6 21 10103091SH109
TH2223MSS 25.4 13.4 15.3 5.0 10.4 24 10103091SH128
TH2224MSS 35.1 14.4 16.3 5.0 10.4 25 10103091SH128
TH2261SSDC 13.3 9.4 10.1 4.9 9.4 18 10103091SH109
W
TH2262SSDC 19.3 9.4 10.1 5.2 9.6 19 10103091SH109
TH2263SSDC 25.4 13.4 14.3 5.2 9.6 30 10103091SH113 Heavy Duty NEMA Type 4/4X
TH3221SS 11.3 7.4 8.1 4.9 9.4 12 10103091SH109
TH3221SS-BA 11.3 7.4 8.1 4.9 9.4 12 10103091SH109
TH3221SSW 11.3 7.4 8.1 4.9 9.4 12 10103091SH109
TH3222SS 19.3 9.4 10.1 5.2 9.6 15 10103091SH109
TH3222SS-BA 19.3 9.4 10.1 5.2 9.6 15 10103091SH109
TH3223SS 25.4 13.4 14.3 5.2 9.6 30 10103091SH113
TH3223SS-BA 25.4 13.4 14.3 5.2 9.6 30 10103091SH113 No KO
TH3223SSW 25.4 13.5 14.2 5.2 9.6 30 10103091SH113
TH3224SS 35.1 14.5 15.5 5.2 9.6 33 10103091SH113
TH3224SS-BA 35.1 14.5 15.5 5.2 9.6 33 10103091SH113
TH3224SSW 35.2 14.5 15.5 5.2 9.6 33 10103091SH113
TH3225SS 59.5 24.6 25.6 8.4 13.8 128 10103091SH119
TH3226SS 59.5 24.6 25.6 8.4 13.8 140 10103091SH119
TH3321MSS 11.2 7.4 8.1 4.7 9.8 14 10103091SH123
TH3321SS 11.3 7.4 8.1 4.9 9.4 12 10103091SH109
TH3321SS-BA 11.3 7.4 8.1 4.9 9.4 12 10103091SH109
TH3322MSS 19.3 9.4 14.1 5.0 10.1 23 10103091SH123
TH3322SS 19.3 9.4 10.1 5.2 9.6 22 10103091SH109
TH3322SS-BA 19.3 9.4 10.1 5.2 9.6 22 10103091SH109
TH3322SSW 19.3 9.4 10.1 5.2 9.6 22 10103091SH109
TH3323MSS 25.4 13.4 15.3 5.0 10.4 23 10103091SH128
TH3324MSS 35.1 14.4 16.3 5.0 10.4 27 10103091SH128
TH3325MSS 59.4 24.5 25.6 7.9 14.4 193 10103091SH130
TH3326MSS 59.4 24.5 25.6 7.9 14.4 200 10103091SH130
TH3361MSS 19.3 9.4 14.1 5.0 10.1 21 10103091SH123
TH3361SS 13.3 9.4 10.1 4.9 9.4 17 10103091SH109
TH3361SS-BA 13.3 9.4 10.1 4.9 9.4 17 10103091SH109
(table continued on next page)

Rev. 11/13 www.geindustrial.com BuyLog Catalog 4-29


Data subject to change
without notice
Safety Switches Section 4
Enclosure Dimensions
Spec-Setter Safety Switches
TH and THN, NEMA Type 4/4X Enclosures

Heavy Duty, NEMA Type 4/4X Water/Dust-tight (Cont.) Approximate Dimensions in inches
Product Dimension Dimension Dimension W2 Dimension Dimension D2 Weight KO Figure D2
Number H W (Box) (W/ Handle) D (Box) (W/ Handle) (lbs) Drawing # Number D
W2
TH3361SSW 13.3 9.4 10.1 4.9 9.4 18 10103091SH109
TH3362MSS 19.3 9.4 14.1 5.0 10.1 23 10103091SH123
TH3362MSSW 19.3 9.4 14.1 5.0 10.1 23 10103091SH123
TH3362SS 19.3 9.4 10.1 5.2 9.6 23 10103091SH109
TH3362SS-BA 19.3 9.4 10.1 5.2 9.6 23 10103091SH109
H
TH3362SSW 19.3 9.4 10.1 5.2 9.6 22 10103091SH109
TH3363MSS 25.4 13.4 15.3 5.0 10.4 23 10103091SH128
TH3363SS 25.4 13.4 14.3 5.2 9.6 36 10103091SH113
TH3363SS-BA 25.4 13.4 14.3 5.2 9.6 36 10103091SH113
TH3363SSW 25.4 13.5 14.2 5.2 9.6 35 10103091SH113
TH3364MSS 35.1 14.4 16.3 5.0 10.4 45 10103091SH128
W
TH3364SS 35.1 14.5 15.5 5.2 9.6 49 10103091SH113
TH3364SS-BA 35.1 14.5 15.5 5.2 9.6 49 10103091SH113 Heavy Duty NEMA Type 4/4X
TH3364SSW 35.2 14.5 15.5 5.2 9.6 33 10103091SH113
TH3365MSS 59.4 24.5 25.6 7.9 14.4 206 10103091SH130
TH3365SS 59.5 24.6 25.6 8.4 13.8 131 10103091SH119
TH3366MSS 59.4 24.5 25.6 7.9 14.4 211 10103091SH130
TH3366SS 59.5 24.6 25.6 8.4 13.8 139 10103091SH119
TH4321SS 11.3 7.4 8.1 4.9 9.4 12 10103091SH109
TH4321SS-BA 11.3 7.4 8.1 4.9 9.4 12 10103091SH109
TH4321SSW 11.3 7.4 8.1 4.9 9.4 12 10103091SH109
TH4322SS 19.3 9.4 10.1 5.2 9.6 23 10103091SH109
TH4322SS-BA 19.3 9.4 10.1 5.2 9.6 23 10103091SH109
TH4322SSW 19.3 9.4 10.1 5.2 9.6 23 10103091SH109
TH4323SS 25.4 13.4 14.3 5.2 9.6 36 10103091SH113
TH4323SS-BA 25.4 13.4 14.3 5.2 9.6 36 10103091SH113
TH4323SSW 25.4 13.5 14.2 5.2 9.6 36 10103091SH113
TH4324SS 35.1 14.5 15.5 5.2 9.6 47 10103091SH113
TH4324SS-BA 35.1 14.5 15.5 5.2 9.6 47 10103091SH113
TH4324SSW 35.2 14.5 15.5 5.2 9.6 47 10103091SH113 No KO
TH4325SS 59.5 24.6 25.6 8.4 13.8 135 10103091SH119
TH4326SS 59.5 24.6 25.6 8.4 13.8 139 10103091SH119
THN2261SSDC 11.3 9.4 10.1 4.9 9.4 16 10103091SH109
THN2262SSDC 13.3 9.4 10.1 5.2 9.6 16 10103091SH109
THN2263SSDC 25.4 13.4 14.3 5.2 9.6 30 10103091SH113
THN3361MSS 19.3 9.4 14.1 5.0 10.1 22 10103091SH123
THN3361MSSW 19.3 9.4 14.1 5.0 10.1 22 10103091SH123
THN3361SS 11.3 9.4 10.1 4.9 9.4 16 10103091SH109
THN3361SS-BA 11.3 9.4 10.1 4.9 9.4 16 10103091SH109
THN3361SSCL 13.3 9.4 10.1 5.2 9.6 9 10103091SH109
THN3361SSW 11.3 9.4 10.1 4.9 9.4 19 10103091SH109
THN3362MSS 19.3 9.4 14.1 5.0 10.1 15 10103091SH123
THN3362SS 13.3 9.4 10.1 5.2 9.6 21 10103091SH109
THN3362SS-BA 13.3 9.4 10.1 5.2 9.6 21 10103091SH109
THN3362SSCL 13.3 9.4 10.1 5.2 9.6 21 10103091SH109
THN3362SSW 13.3 9.4 10.1 5.2 9.6 22 10103091SH109
THN3363MSS 25.4 13.4 15.3 5.0 10.4 20 10103091SH128
THN3363SS 25.4 13.4 14.3 5.2 9.6 36 10103091SH113
THN3363SS-BA 25.4 13.4 14.3 5.2 9.6 36 10103091SH113
THN3363SSW 25.4 13.5 14.2 5.2 9.6 36 10103091SH113
THN3364MSS 35.1 14.4 16.3 5.0 10.4 32 10103091SH128
THN3364SS 35.1 14.5 15.5 5.2 9.6 50 10103091SH113
THN3364SS-BA 35.1 14.5 15.5 5.2 9.6 50 10103091SH113
THN3364SSCL 35.1 14.5 15.5 5.2 9.6 32 10103091SH113
THN3364SSW 35.2 14.5 15.5 5.2 9.6 32 10103091SH113
THN3365MSS 47.9 24.5 25.6 7.9 14.4 110 10103091SH130
THN3365SS 48.0 24.6 25.6 8.4 13.7 239 10103091SH119
THN3366MSS 47.9 24.5 25.6 7.9 14.4 110 10103091SH130
THN3366SS 48.0 24.6 25.6 8.4 13.7 139 10103091SH119

4-30 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Safety Switches Section 4
Enclosure Dimensions
Spec-Setter Safety Switches
TH and THN, NEMA Type 5/12 Enclosures

Heavy Duty, NEMA Type 5, 12 Drip/Dust-tight Approximate Dimensions in inches D2


Product Dimension Dimension Dimension W2 Dimension Dimension D2 Weight KO Figure D
Number H W (Box) (W/ Handle) D (Box) (W/ Handle) (lbs) Drawing # Number W2

TH2221J 11.3 7.4 8.1 5.4 10.0 12 10103091SH110


TH2221JW 11.3 7.4 8.1 5.4 10.0 12 10103091SH110
TH2222J 19.3 9.4 10.1 5.7 10.2 21 10103091SH110
TH2222JW 19.3 9.4 10.1 5.7 10.2 21 10103091SH110
TH2261JDC 13.3 9.4 10.1 5.4 10.0 16 10103091SH109 H
TH2262JDC 19.3 9.4 10.1 5.7 10.2 22 10103091SH109
TH2263JDC 25.4 13.4 14.0 5.0 10.1 35 10103091SH113
TH3221J 11.3 7.4 8.1 5.4 10.0 12 10103091SH110
TH3221JW 11.3 7.4 8.1 5.4 10.0 12 10103091SH110
TH3222J 19.3 9.4 10.1 5.7 10.2 15 10103091SH110
TH3222JW 19.3 9.4 10.1 5.7 10.2 15 10103091SH110 W
TH3223J 25.4 13.4 14.0 5.0 10.1 37 10103091SH120
TH3223JW 25.4 13.4 14.0 5.0 10.1 37 10103091SH120 Heavy Duty NEMA Type 5/12
TH3224J 35.1 14.5 15.1 5.0 10.1 33 10103091SH120
TH3224JW 35.1 14.5 15.1 5.0 10.1 33 10103091SH120
TH3225J 59.5 24.5 25.6 7.9 14.5 120 10103091SH124
TH3226J 59.5 24.5 25.6 7.9 14.5 134 10103091SH124
TH3321J 11.3 7.4 8.1 5.4 10.0 12 10103091SH110
TH3321JW 11.3 7.4 8.1 5.4 10.0 12 10103091SH110
TH3322J 19.3 9.4 10.1 5.7 10.2 21 10103091SH110
TH3322JCH 19.3 9.4 9.8 5.7 10.3 28 10103091SH132
TH3322JW 19.3 9.4 10.1 5.7 10.2 21 10103091SH110
TH3361J 13.3 9.4 10.1 5.4 10.0 16 10103091SH110
TH3361JW 13.3 9.4 10.1 5.4 10.0 16 10103091SH110
TH3362J 19.3 9.4 10.1 5.7 10.2 22 10103091SH110
TH3362JCH 19.3 9.4 9.8 5.7 10.3 31 10103091SH132
TH3362JCHSS 19.3 9.4 9.8 5.7 10.3 32 10103091SH132
TH3362JW 19.3 9.4 10.1 5.7 10.2 22 10103091SH110
TH3363J 25.4 13.4 14.0 5.0 10.1 36 10103091SH120
TH3363JW 25.4 13.4 14.0 5.0 10.1 35 10103091SH120 No KO
TH3364J 35.1 14.5 15.1 5.0 10.1 49 10103091SH120
TH3364JW 35.1 14.5 15.1 5.0 10.1 33 10103091SH120
TH3365J 59.5 24.5 25.6 7.9 14.5 206 10103091SH124
TH3366J 59.5 24.5 25.6 7.9 14.5 215 10103091SH124
TH4321J 11.3 7.4 8.1 5.4 10.0 12 10103091SH110
TH4321JW 11.3 7.4 8.1 5.4 10.0 12 10103091SH110
TH4322J 19.3 9.4 10.1 5.7 10.2 22 10103091SH110
TH4322JW 19.3 9.4 10.1 5.7 10.2 22 10103091SH110
TH4323J 25.4 13.4 14.0 5.0 10.1 36 10103091SH120
TH4323JW 25.4 13.4 14.0 5.0 10.1 36 10103091SH120
TH4324J 35.1 14.5 15.1 5.0 10.1 52 10103091SH120
TH4324JW 35.1 14.5 15.1 5.0 10.1 52 10103091SH120
TH4325J 59.5 24.5 25.6 7.9 14.5 128 10103091SH124
TH4326J 59.5 24.5 25.6 7.9 14.5 139 10103091SH124
THN2261JDC 13.3 9.4 10.1 5.4 10.0 16 10103091SH110
THN2262JDC 19.3 9.4 10.1 5.7 10.2 15 10103091SH110
THN2263JDC 25.4 13.4 14.0 5.0 10.1 34 10103091SH120
THN3361J 13.3 9.4 10.1 5.4 10.0 16 10103091SH110
THN3361JCL 13.3 9.4 10.1 5.4 10.0 22 10103091SH110
THN3361JW 13.3 9.4 10.1 5.4 10.0 16 10103091SH110
THN3362J 19.3 9.4 10.1 5.7 10.2 21 10103091SH110
THN3362JCH 19.3 9.4 9.8 5.7 10.3 21 10103091SH132
THN3362JW 19.3 9.4 10.1 5.7 10.2 21 10103091SH110
THN3363J 25.4 13.4 14.0 5.0 10.1 34 10103091SH120
THN3363JCL 25.4 13.4 14.0 5.0 10.1 33 10103091SH120
THN3363JW 25.4 13.4 14.0 5.0 10.1 33 10103091SH120
THN3364J 35.1 14.5 15.1 5.0 10.1 47 10103091SH120
THN3364JW 35.1 14.5 15.1 5.0 10.1 47 10103091SH120
THN3365J 48.0 24.5 25.6 7.9 14.5 164 10103091SH124
THN3366J 48.0 24.5 25.6 7.9 14.5 109 10103091SH124

Rev. 11/13 www.geindustrial.com BuyLog Catalog 4-31


Data subject to change
without notice
Safety Switches Section 4
Enclosure Dimensions
Spec-Setter Safety Switches
TH and THN, NEMA Type 3R/5/12 Enclosures

Heavy Duty, NEMA Type 3R, 5, 12 Approximate Dimensions in inches D2


Product Dimension Dimension Dimension W2 Dimension Dimension D2 Weight KO Figure D
Number H W (Box) (W/ Handle) D (Box) (W/ Handle) (lbs) Drawing # Number W2

TH3361JR 13.3 9.4 10.1 5.4 10.0 17 10103091SH110


TH3362JR 19.3 9.4 10.1 5.7 10.2 23 10103091SH132
TH3363JR 25.4 13.4 14.0 5.0 10.1 38 10103091SH120 20
TH3364JR 35.1 14.5 15.1 5.0 10.1 49 10103091SH120
TH3365JR 59.5 24.5 25.6 7.9 14.5 197 10103091SH124 H
TH3366JR 59.5 24.5 25.6 7.9 14.5 212 10103091SH124

Heavy Duty, NEMA Type 12 Drip/Dust-tight Approximate Dimensions in inches


Product Dimension Dimension Dimension W2 Dimension Dimension D2 Weight KO Figure W
Number H W (Box) (W/ Handle) D (Box) (W/ Handle) (lbs) Drawing # Number
TH2221M 11.3 7.4 8.1 4.7 9.9 13 10103091SH123 Heavy Duty NEMA Type 3R/5/12
TH2222M 19.3 9.4 14.1 5.0 10.1 23 10103091SH123
TH2223M 23.4 13.4 15.3 5.0 10.1 24 10103091SH128
TH2224M 35.1 14.4 16.3 5.0 10.1 25 10103091SH128
TH2261MDC 19.3 9.4 14.1 5.0 10.1 20 10103091SH123
TH2262MDC 19.3 9.4 14.1 5.0 10.1 22 10103091SH123
TH2263MDC 23.4 13.4 15.3 5.0 10.1 35 10103091SH128 D2
TH3321M 11.3 7.4 8.1 4.7 9.9 13 10103091SH123 D
TH3322M 19.3 9.4 14.1 5.0 10.1 21 10103091SH123 W2
TH3322MW 19.3 9.4 14.1 5.0 10.1 21 10103091SH123
TH3323M 23.4 13.4 15.3 5.0 10.1 24 10103091SH128
TH3324M 35.1 14.4 16.3 5.0 10.1 30 10103091SH128
TH3325M 59.4 24.5 25.6 7.9 14.4 193 10103091SH130
TH3326M 59.4 24.5 25.6 7.9 14.4 200 10103091SH130 H
TH3361M 19.3 9.4 14.1 5.0 10.1 22 10103091SH123
TH3361MW 19.3 9.4 14.1 5.0 10.1 22 10103091SH123 No KO
TH3362M 19.3 9.4 14.1 5.0 10.1 22 10103091SH123
TH3363M 23.4 13.4 15.3 5.0 10.1 35 10103091SH128
TH3364M 35.1 14.4 16.3 5.0 10.1 45 10103091SH128
TH3365M 59.4 24.5 25.6 7.9 14.4 206 10103091SH130 W
TH3366M 59.4 24.5 25.6 7.9 14.4 211 10103091SH130
THN2261MDC 19.3 9.4 14.1 5.0 10.1 20 10103091SH123 Heavy Duty NEMA Type 5/12
THN2262MDC 19.3 9.4 14.1 5.0 10.1 20 10103091SH123
THN2263MDC 23.4 13.4 15.3 5.0 10.1 35 10103091SH128
THN3361M 19.3 9.4 14.1 5.0 10.1 21 10103091SH123
THN3362M 19.3 9.4 14.1 5.0 10.1 15 10103091SH123
THN3362MW 19.3 9.4 14.1 5.0 10.1 15 10103091SH123
THN3363M 23.4 13.4 15.3 5.0 10.1 20 10103091SH128
THN3364M 35.1 14.4 16.3 5.0 10.1 35 10103091SH128
THN3365M 47.9 24.5 25.6 7.9 14.4 110 10103091SH130
THN3366M 47.9 24.5 25.6 7.9 14.4 110 10103091SH130

4-32 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Safety Switches Section 4
Enclosure Dimensions
Spec-Setter Safety Switches
TC, NEMA Type 1 and 3R Enclosures

Double Throw, NEMA Type 1 TC Approximate Dimensions in inches


D2
Product Dimension Dimension Dimension W2 Dimension Dimension D2 Weight KO Figure W2 D
Number H W (Box) (W/ Handle) D (Box) (W/ Handle) (lbs) Drawing # Number
TC35321 15.8 10.4 12.0 5.2 8.7 14 10103091SH115 7
TC35322 18.8 11.4 13.0 6.3 9.3 19 10103091SH115 7
TC35323 22.4 14.5 16.0 7.9 14.5 34 10103091SH117 9
TC35324 30.2 17.9 19.5 8.9 11.9 54 10103091SH117 10
TC35325 34.3 24.5 26.7 10.3 17.1 83 10103091SH122 10
TC35326 44.4 23.5 25.6 11.3 17.5 140 10103091SH122 12
TC35327 63.8 27.0 27.8 8.9 14.1 175 10103091SH143
TC35327N 63.8 27.0 27.8 8.9 14.1 175 10103091SH143 H
No KO
TC35328 78.1 42.6 43.8 20.5 29.6 471 10103091SH145
TC35361 25.0 12.0 12.8 6.0 11.2 44 10103091SH185
TC35362 18.8 11.4 13.0 6.3 9.3 21 10103091SH115 7
TC35363 22.4 14.5 16.0 7.9 14.5 38 10103091SH117 9
TC35364 30.2 17.9 19.5 8.9 11.9 62 10103091SH117 10
TC35365 34.3 20.4 22.6 10.3 17.1 89 10103091SH122 10
TC35366 44.4 23.5 25.6 11.3 17.5 140 10103091SH122 12
TC35367 63.8 27.0 27.8 8.9 14.1 175 10103091SH143
TC35367N 63.8 27.0 27.8 8.9 14.1 175 10103091SH143 No KO W

TC35368 78.1 42.6 43.8 20.5 29.6 471 10103091SH145


Double Throw NEMA Type 1

Double Throw, NEMA Type 3R TC Approximate Dimensions in inches


Product Dimension Dimension Dimension W2 Dimension Dimension D2 Weight KO Figure W2
D2
D
Number H W (Box) (W/ Handle) D (Box) (W/ Handle) (lbs) Drawing # Number
TC10323R 15.1 7.2 8.2 5.2 8.5 10 10103091SH131 15
TC10324R 30.2 13.3 16.8 8.5 12.1 38 10103091SH131 13
TC10424R 30.2 13.3 16.8 8.5 12.1 38 10103091SH131 13
TC35321R 19.8 10.4 12.3 5.2 10.3 14 10103091SH126
TC35322R 20.8 11.4 13.3 6.3 11.4 19 10103091SH126
TC35323R 22.9 14.4 16.6 7.9 14.5 35 10103091SH125
TC35324R 30.6 17.9 19.6 8.9 1.9 54 10103091SH125
TC35325R 34.8 24.4 27.3 10.3 17.3 98 10103091SH143 H

TC35326R 63.8 23.7 24.5 8.9 14.1 175 10103091SH143


TC35327R 63.8 27.0 27.8 8.9 14.1 175 10103091SH143
TC35327RN 63.8 27.0 27.8 8.9 14.1 175 10103091SH143
TC35328R 78.1 42.6 43.8 20.5 29.6 473 10103091SH145
No KO
TC35361R 25.0 12.0 12.8 6.0 11.2 44 10103091SH185
TC35362R 20.8 11.4 13.3 6.3 11.4 21 10103091SH126
TC35363R 22.9 14.4 16.6 7.9 14.5 39 10103091SH125
TC35364R 30.6 17.9 19.6 8.9 1.9 62 10103091SH125
TC35365R 54.3 22.7 23.5 7.3 12.5 140 10103091SH143 W
TC35366R 63.8 23.7 24.5 8.9 14.1 175 10103091SH143
TC35367R 63.8 27.0 27.8 8.9 14.1 175 10103091SH143 Double Throw NEMA Type 3R
TC35367RN 63.8 27.0 27.8 8.9 14.1 175 10103091SH143
TC35368R 78.1 42.6 43.8 20.5 29.6 473 10103091SH145

Rev. 11/13 www.geindustrial.com BuyLog Catalog 4-33


Data subject to change
without notice
Safety Switches Section 4
Enclosure Dimensions
Spec-Setter Safety Switches
TDT and TC, NEMA Type 1, 3R and 4X Enclosures

Double Throw, NEMA Type 1 TDT Approximate Dimensions in inches D2


Product Dimension Dimension Dimension W2 Dimension Dimension D2 Weight KO Figure W2 D

Number H W (Box) (W/ Handle) D (Box) (W/ Handle) (lbs) Drawing # Number
TDT3321 37.0 12.0 12.8 8.3 11.2 47 10103091SH137
TDT3322 37.0 12.0 12.8 8.3 11.2 43 10103091SH137
TDT3323 37.0 12.0 12.8 8.3 11.2 48 10103091SH137
TDT3324 51.4 19.2 19.9 6.1 11.3 159 10103091SH138
TDT3325 74.7 25.3 26.2 8.9 14.1 163 10103091SH139
TDT3326 86.1 27.4 28.3 8.9 14.1 341 10103091SH139
TDT3327 58.9 28.1 29.3 20.5 25.6 275 10103091SH147
H
TDT3328 78.1 42.6 43.8 20.5 29.6 501 10103091SH146 No KO
TDT3361 37.0 12.0 12.8 8.3 11.2 42 10103091SH137
TDT3362 37.0 12.0 12.8 8.3 11.2 43 10103091SH137
TDT3363 37.0 12.0 12.8 8.3 11.2 62 10103091SH137
TDT3364 51.4 27.6 28.6 8.8 16.2 102 10103091SH138
TDT3365 74.7 25.3 26.2 8.9 14.1 274 10103091SH139
TDT3366 58.9 28.1 29.3 20.5 25.6 278 10103091SH144
TDT3367 58.9 28.1 29.3 20.5 25.6 278 10103091SH145
TDT3368 78.1 42.6 43.8 20.5 29.6 501 10103091SH146
W

Double Throw NEMA Type 1


Double Throw, NEMA Type 3R TDT Approximate Dimensions in inches
Product Dimension Dimension Dimension W2 Dimension Dimension D2 Weight KO Figure
Number H W (Box) (W/ Handle) D (Box) (W/ Handle) (lbs) Drawing # Number
D2
W2 D
TDT3321R 37.0 12.0 12.8 8.3 11.2 47 10103091SH137
TDT3322R 37.0 12.0 12.8 8.3 11.2 47 10103091SH137
TDT3323R 37.0 12.0 12.8 8.3 11.2 62 10103091SH137
TDT3324R 51.4 27.6 28.6 8.8 16.2 159 10103091SH138
TDT3325R 74.8 26.3 24.5 8.8 14.1 230 10103091SH143
TDT3326R 58.9 28.1 29.3 20.5 25.6 320 10103091SH144
TDT3327R 58.9 28.1 29.3 20.5 25.6 276 10103091SH147
TDT3328R 78.1 42.6 43.8 20.5 29.6 503 10103091SH146 No KO
TDT3361R 37.0 12.0 12.8 6.0 11.9 44 10103091SH185
H
TDT3362R 37.0 12.0 12.8 6.0 11.9 44 10103091SH185
TDT3363R 37.0 12.0 12.8 8.3 11.2 49 10103091SH137
TDT3364R 51.4 27.6 28.6 8.8 16.2 160 10103091SH138
TDT3365R 74.8 26.3 24.5 8.8 14.1 230 10103091SH143
TDT3366R 58.9 28.1 29.3 20.5 25.6 278 10103091SH144
TDT3367R 58.9 28.1 29.3 20.5 25.6 278 10103091SH147
TDT3368R 78.1 42.6 43.8 20.5 29.6 503 10103091SH146

Double Throw, NEMA Type 4X (304 Stainless) TC Approximate Dimensions in inches


W

Product Dimension Dimension Dimension W2 Dimension Dimension D2 Weight KO Figure Double Throw NEMA Type 3R
Number H W (Box) (W/ Handle) D (Box) (W/ Handle) (lbs) Drawing # Number
TC35361SS 25.7 11.9 12.7 5.5 11.4 60 10103091SH150
TC35362SS 25.7 11.9 12.7 5.5 11.4 60 10103091SH150
D2
TC35363SS 25.7 11.9 12.7 5.5 11.4 60 10103091SH150 W2 D
TC35364SS 39.8 19.6 20.3 6.5 11.7 105 10103091SH186 No KO
TC35365SS 37.9 19.6 20.3 6.5 14.1 185 10103091SH149
TC35366SS 67.0 24.1 25.3 9.0 14.0 195 10103091SH188
TC35367SS 63.3 27.4 28.4 8.9 14.1 230 10103091SH187

Double Throw, NEMA Type 4X (304 Stainless) TDT Approximate Dimensions in inches
Product Dimension Dimension Dimension W2 Dimension Dimension D2 Weight KO Figure
Number H W (Box) (W/ Handle) D (Box) (W/ Handle) (lbs) Drawing # Number
TDT3361SS 38.8 12.0 12.8 5.5 11.4 45 10103091SH148 W
TDT3362SS 38.8 12.0 12.8 5.5 11.4 45 10103091SH148
TDT3363SS 38.8 12.0 12.8 5.5 11.4 45 10103091SH148 No KO Double Throw NEMA Type 4X
TDT3364SS 53.3 19.6 20.3 6.5 11.6 100 10103091SH142
TDT3365SS 37.9 19.6 20.3 6.5 14.1 260 10103091SH149

Accessories and Lug Sizes: See pages 2-25 to 2-30


Outlines, Dimensions and Knockouts: See pages 2-31 to 2-39

4-34 BuyLog Catalog www.geindustrial.com Rev. 7/13


Data subject to change
without notice
Safety Switches Section 4
Enclosure Dimensions
Spec-Setter Safety Switches
TG, TH, TC, NEMA Type 1, 3R Enclosures

Dimensions-Knockouts
Symbol A B C D E F G H J K L M N
9/32 1/2 1/2 1/2 1/2 1/2 3/4 3/4 1 1 2 2 2 1/ 2
Conduit
3/4 3/4 3/4 3/4 1 1 1 1/4 1 1/2 2 1/2 2 1/2 3
Size
(Inches) 1 1 1 1 1/4 1 1/2 2 3 3
1 1/4 1 1/2 1 1/ 2 2 2 1/2 3 1/2

Figure 1 Figure 2 Figure 3 Figure 4 Figure 5

Figure 6 Figure 7 Figure 8 Figure 9 Figure 10

Figure 11 Figure 12 Figure 13 Figure 14 Figure 15

Figure 16 Figure 17 Figure 18 Figure 19 Figure 20

Rev. 7/13 www.geindustrial.com BuyLog Catalog 4-35


Data subject to change
without notice
Safety Switches Section 4
Enclosure Dimensions
Spec-Setter Safety Switches
TG, TH and TS, NEMA Type 1 and 3R Enclosures

For additional information on GE safety switches,


please visit the Publication Library at www.geindustrial.com
to view and download the following resources:
Pub. Number Title
GEA-12144 Spec Setter Safety Switches
DET-842 Stainless Steel Safety Switches Sealed Tight Latch It!
DEE-576 General Duty Safety Switches
DEQ-219 GE's Side-Swing Safety Switches
DET-843 GE Residential Products and Solutions
DEA-464 Small Projects Same Day Flyer
DET-651 Small Projects Selection Guide

4-36 BuyLogx Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Surge Protection Devices (SPD) Section 5

Critical Power Products


Introduction ....................................................................................................5-2
Integrated Tranquell ME (to connect with
GE ASeries Panelboards).....................................................................5-3
Integrated Tranquell HE and ME
(for GE Distribution Equipment) ..........................................................5-5
Tranquell 9X and 24X (Box Extensions for
GE A Series Distribution Equipment) .............................................5-8
Tranquell HE and ME (Wall Mount) ....................................................5-12
Tranquell ME and LE (Wall Mount) .....................................................5-18
Tranquell DIN Rail Mount .......................................................................5-20
Protection Block Assembly ......................................................................5-22

Rev. 11/13 www.geindustrial.com BuyLog Catalog 5-1


Data subject to change
without notice
Surge Protection Device (SPD) Section 5
Critical Power Products
Introduction

General Electric has been a leader in lightning and surge


protection for commercial, industrial and utility applications for
decades. The GE Surge Protection Device product line utilizes the
combined strengths of GE engineering capabilities and surge
suppression technology.
GE SPD products use quality materials and innovative designs
to achieve the best possible performance while maintaining
competitive prices. All units are 3rd party tested to the NEMA LS-1
standards, are rated in accordance with NEC Article 285 and
comply with UL1449, 3rd Edition. We have a full line of SPD
products available, integral to GE Distribution Equipment,
or wall mounted.
GE has a strong commitment to customer service. We offer a
level of service and engineering support unmatched by our
competition. Many of our products are designed to suit specific
customer applications. Our application engineering team is ready
to provide solutions for your surge suppression needs.
Contact your local GE sales office for additional information.

References
Integrated SPD DEA-390, DEA-391, DEA-393, DEA-394
Wall Mounted DEA-300, DEA-320, DEA-391, DEA-392

5-2 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Surge Protection Device (SPD) Section 5
Critical Power Products
Integrated Tranquell ME
Designed to Connect within GE A Series Panelboards

This SPD model connects directly to the A Series Panelboard bus


bars without adding width or depth to the panel enclosure. These
devices have been tested to surge current ratings per NEMA LS-1,
including the fuses in the surge path. Since these surge protection
units are mounted to the bus bars, a breaker feeder is not
required or used. This design allows for maximum protection.
Ratings are available from 65kA per mode to 100kA per mode.
All mode protection is provided with surge components (MOVs)
connected on the phase to neutral, phase to ground, and neutral
to ground paths as appropriate for the voltage configuration.
Integrated Tranquell ME products are engineered for reliability,
flexibility and long life in the most extreme surge environment.
The true maximum surge current rating, unlimited by fusing, has
been proven successful in 3rd party tests.

Features and Benefits Specifications


UL1449, 3rd Edition CUL Operating Frequency: 50/60 Hz
Connection: Direct Bus Connection, Parallel Connected
Optional UL1283 Noise Filters Operating Temperature: -40C to +65C
UL Tested to 65,000 Amperes Symmetrical Withstand Operating Humidity: 0% to 95% Non-Condensing
Weight: 13 lbs.
Tranquell ME Device is Capable of Surviving a minimum of
5,000 Category C3 Impulses (10kA, 20kV) per mode
Form C Dry Contacts for Remote Monitoring
Green Status Indicating Lights, Red Service Light
Audible Alarm with Test/Disable Feature
Standard Surge Counter on AS
Factory installed in GE "A Series" Panels
Standard 5 year limited warranty, Optional 20 year warranty

1.331 [33.81]
5.064 [128.62]
0.312 [7.91] TYP

0.236 [ 5.99] HOLE


(4 PLACES)

5.331 [135.41]
6.000 [152.40]
8.321 [211.36]

9.494 [241.15]

2.869 [72.87]

9.400 [238.76]

Rev. 11/13 www.geindustrial.com BuyLog Catalog 5-3


Data subject to change
without notice
Surge Protection Device (SPD) Section 5
Critical Power Products
Integrated Tranquell ME
Designed to Connect within GE "A Series" Panelboards

For GE "A" Series Panelboards - 65 kA Symmetrical


Fault Withstand
Panelboard, Lights, Alarm, Surge Counter, Form C Contacts
Maximum Surge Current Product Number
65kA per mode / 130kA per phase TPME120S06AS
65kA per mode / 130kA per phase TPME120Y06AS
65kA per mode / 130kA per phase TPME220Y06AS
65kA per mode / 130kA per phase TPME277Y06AS
65kA per mode / 130kA per phase TPME480D06AS
65kA per mode / 130kA per phase TPME347Y06AS
65kA per mode / 130kA per phase TPME240H06AS
65kA per mode / 130kA per phase TPME240D06AS
65kA per mode / 130kA per phase TPME240Y06AS
65kA per mode / 130kA per phase TME600D065AS
80kA per mode / 160kA per phase TPME120S08AS
80kA per mode / 160kA per phase TPME120Y08AS
80kA per mode / 130kA per phase TPME220Y08AS
80kA per mode / 160kA per phase TPME277Y08AS
80kA per mode / 160kA per phase TPME480D08AS
80kA per mode / 160kA per phase TPME347Y08AS
80kA per mode / 160kA per phase TPME240H08AS
80kA per mode / 160kA per phase TPME240D08AS
80kA per mode / 160kA per phase TPME240Y08AS
80kA per mode / 160kA per phase TME600D080AS
100kA per mode / 200kA per phase TPME120S10AS
100kA per mode / 200kA per phase TPME120Y10AS
100kA per mode / 200kA per phase TPME220Y10AS
100kA per mode / 200kA per phase TPME277Y10AS
100kA per mode / 200kA per phase TPME480D10AS
100kA per mode / 200kA per phase TPME347Y10AS
100kA per mode / 200kA per phase TPME240H10AS
100kA per mode / 200kA per phase TPME240D10AS
100kA per mode / 200kA per phase TPME240Y10AS
100kA per mode / 200kA per phase TME600D100AS

Product # T P M E * * AS = Full featured, with UL 1283 noise filtering and surge counter
ASNF = without UL 1283 noise filtering (Available 100kA per Mode) only
ASNC = without UL 1283 noise filtering, without surge counter
(Available 100kA per Mode) only

Voltage Protection Rating (VPR) Maximum Surge


UL 1449, 3rd Edition MCOV % Current Capacity
Nominal System Max.
September 2009 Revision Continuous Per Mode Per Phase
Voltage Voltage Operating
(Volts RMS) Configuration L-N HL-N L-G HL-G N-G L-L Voltage 06 65kA 130kA
120S 120/240 1 Ph, 3 W + G 700 600 600 1200 125% 08 80kA 160kA
120Y 120Y/208 3 Ph, 4 W + G 700 600 600 1200 125% 10 100kA 200kA
240D 240 Delta 3 Ph, 3 W 900 1800 115%
240H 120/240 Delta HL 3 Ph, 4 W + G 700 1200 600 1000 600 1200 115%
Phase Rating = (L-N + L-G)
240Y 240Y/415 3 Ph, 4 W + G 1200 1000 1000 2000 130%
277Y 277Y/480 3 Ph, 4 W + G 1200 1000 1000 2000 115% Product # Example
TPME277Y10AS
220Y 220Y/380 3 Ph, 4 W + G 1200 1000 1000 2000 145%
347Y 347Y/600 3 Ph, 4 W + G 1500 1500 1500 3000 115% 277Y/480 V, 3 Ph, 4 W + G
100kA per mode
480D 480 Delta 3 Ph, 3 W 1500 3000 170% Full featured, with UL 1283 noise
Also available in 600D configurations. For details, please contact GE Power Quality Customer Service at 800 637 1738. filtering and surge counter

5-4 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Surge Protection Device (SPD) Section 5
Critical Power Products
Integrated Tranquell HE and ME
Designed for GE Distribution Equipment

This SPD model connects to the panelboard or switchboard bus


bars without adding width or depth to the panel enclosure, and
only occupying 7X of vertical bus space. These units have been
tested to surge current ratings per NEMA LS-1, up to 200 kA per
mode, including the fuses in the surge path. Standard features
include a surge counter, audible alarm, indicating lights, dry
contacts, and an integral surge rated disconnect. Rating options
range from 65 kA per mode to 300 kA per mode.
All mode protection is provided with surge components (MOVs)
connected on the phase to neutral, phase to ground, and neutral
to ground paths as appropriate for the voltage configuration.
Integrated Tranquell HE and ME products are engineered for
reliability, flexibility and long life in the most extreme surge
environment. The true maximum surge current rating, unlimited
by fusing, has been proven successful in 3rd party tests.

Features and Benefits Specifications


Operating Frequency: 50/60 Hz
UL1449, 3rd Edition CUL, UL1283
Connection: 6 to 2/0 Conductors, Parallel Connected
UL Tested to 200,000 Amperes Symmetrical Withstand Operating Temperature: -40C to +65C
Integral Surge Rated Disconnect Operating Humidity: 0% to 95% Non-Condensing
Weight: 24 lbs.
Factory installed in Spectra Series Panels and Switchboards
(7X Mounting Space), or Switchgear
Tranquell ME Device is Capable of Surviving a minimum of
5,000 Category C3 Impulses (10kA, 20kV) per mode.
Tranquell HE Device is Capable of Surviving a minimum of
20,000 Category C3 Impulses (10kA, 20kV) per mode.
Device Capable of Surviving a minimum of 5,000 Longwave
(10x1000ms) Impulses per mode.
Enhanced Thermal Protection Technology
Form C Dry Contacts for Remote Monitoring
Green Status Indicating Lights, Red Service Light
Audible Alarm with Test/Disable Feature
Standard Surge Counter
Standard 5 year limited warranty, Optional 20 year warranty

17.722 0.280
[450.130] 6.964
[ 7.112] HOLE [176.877]
17.382
0.340 (4 PLACES)
[441.494]
[8.636]
9.400
[238.755]

6.762
[171.751] TYP

2.638
[67.004] TYP
[182.922]
7.202

Rev. 11/13 www.geindustrial.com BuyLog Catalog 5-5


Data subject to change
without notice
Surge Protection Device (SPD) Section 5
Critical Power Products
Integrated Tranquell HE and ME
Designed for GE Distribution Equipment

For GE MCC Distribution Equipment For GE Spectra Panel or Switch Board Distribution Equipment -
200 kA Symmetrical Fault Withstand 200 kA Symmetrical Fault Withstand
Panelboard, Lights, Alarm, Surge Counter, Form C Contacts Panelboard, Lights, Alarm, Surge Counter, Form C Contacts
Maximum Surge Current Product Number Maximum Surge Current Product Number
65kA per mode / 130kA per phase TPME120S06ME 65kA per mode / 130kA per phase TPME120S06PP
65kA per mode / 130kA per phase TPME120Y06ME 65kA per mode / 130kA per phase TPME120Y06PP
65kA per mode / 130kA per phase TPME220Y06ME 65kA per mode / 130kA per phase TPME220Y06PP
65kA per mode / 130kA per phase TPME277Y06ME 65kA per mode / 130kA per phase TPME277Y06PP
65kA per mode / 130kA per phase TPME480D06ME 65kA per mode / 130kA per phase TPME480D06PP
65kA per mode / 130kA per phase TPME347Y06ME 65kA per mode / 130kA per phase TPME347Y06PP
65kA per mode / 130kA per phase TPME240H06ME 65kA per mode / 130kA per phase TPME240H06PP
65kA per mode / 130kA per phase TPME240D06ME 65kA per mode / 130kA per phase TPME240D06PP
65kA per mode / 130kA per phase TPME240Y06ME 65kA per mode / 130kA per phase TPME240Y06PP
80kA per mode / 160kA per phase TPME120S08ME 80kA per mode / 160kA per phase TPME120S08PP
80kA per mode / 160kA per phase TPME120Y08ME 80kA per mode / 160kA per phase TPME120Y08PP
80kA per mode / 130kA per phase TPME220Y08ME 80kA per mode / 130kA per phase TPME220Y08PP
80kA per mode / 160kA per phase TPME277Y08ME 80kA per mode / 160kA per phase TPME277Y08PP
80kA per mode / 160kA per phase TPME480D08ME 80kA per mode / 160kA per phase TPME480D08PP
80kA per mode / 160kA per phase TPME347Y08ME 80kA per mode / 160kA per phase TPME347Y08PP
80kA per mode / 160kA per phase TPME240H08ME 80kA per mode / 160kA per phase TPME240H08PP
80kA per mode / 160kA per phase TPME240D08ME 80kA per mode / 160kA per phase TPME240D08PP
80kA per mode / 160kA per phase TPME240Y08ME 80kA per mode / 160kA per phase TPME240Y08PP
100kA per mode / 200kA per phase TPHE120S10ME 100kA per mode / 200kA per phase TPHE120S10PP
100kA per mode / 200kA per phase TPHE120Y10ME 100kA per mode / 200kA per phase TPHE120Y10PP
100kA per mode / 200kA per phase TPHE220Y10ME 100kA per mode / 200kA per phase TPHE220Y10PP
100kA per mode / 200kA per phase TPHE277Y10ME 100kA per mode / 200kA per phase TPHE277Y10PP
100kA per mode / 200kA per phase TPHE480D10ME 100kA per mode / 200kA per phase TPHE480D10PP
100kA per mode / 200kA per phase TPHE347Y10ME 100kA per mode / 200kA per phase TPHE347Y10PP
100kA per mode / 200kA per phase TPHE240H10ME 100kA per mode / 200kA per phase TPHE240H10PP
100kA per mode / 200kA per phase TPHE240D10ME 100kA per mode / 200kA per phase TPHE240D10PP
100kA per mode / 200kA per phase TPHE240Y10ME 100kA per mode / 200kA per phase TPHE240Y10PP
150kA per mode / 300kA per phase TPHE120S15ME 150kA per mode / 300kA per phase TPHE120S15PP
150kA per mode / 300kA per phase TPHE120Y15ME 150kA per mode / 300kA per phase TPHE120Y15PP
150kA per mode / 300kA per phase TPHE220Y15ME 150kA per mode / 300kA per phase TPHE220Y15PP
150kA per mode / 300kA per phase TPHE277Y15ME 150kA per mode / 300kA per phase TPHE277Y15PP
150kA per mode / 300kA per phase TPHE480D15ME 150kA per mode / 300kA per phase TPHE480D15PP
150kA per mode / 300kA per phase TPHE347Y15ME 150kA per mode / 300kA per phase TPHE347Y15PP
150kA per mode / 300kA per phase TPHE240H15ME 150kA per mode / 300kA per phase TPHE240H15PP
150kA per mode / 300kA per phase TPHE240D15ME 150kA per mode / 300kA per phase TPHE240D15PP
150kA per mode / 300kA per phase TPHE240Y15ME 150kA per mode / 300kA per phase TPHE240Y15PP
200kA per mode / 400kA per phase TPHE120S20ME 200kA per mode / 400kA per phase TPHE120S20PP
200kA per mode / 400kA per phase TPHE120Y20ME 200kA per mode / 400kA per phase TPHE120Y20PP
200kA per mode / 400kA per phase TPHE220Y20ME 200kA per mode / 400kA per phase TPHE220Y20PP
200kA per mode / 400kA per phase TPHE277Y20ME 200kA per mode / 400kA per phase TPHE277Y20PP
200kA per mode / 400kA per phase TPHE480D20ME 200kA per mode / 400kA per phase TPHE480D20PP
200kA per mode / 400kA per phase TPHE347Y20ME 200kA per mode / 400kA per phase TPHE347Y20PP
200kA per mode / 400kA per phase TPHE240H20ME 200kA per mode / 400kA per phase TPHE240H20PP
200kA per mode / 400kA per phase TPHE240D20ME 200kA per mode / 400kA per phase TPHE240D20PP
200kA per mode / 400kA per phase TPHE240Y20ME 200kA per mode / 400kA per phase TPHE240Y20PP
300kA per mode / 600kA per phase TPHE120S30ME 300kA per mode / 600kA per phase TPHE120S30PP
300kA per mode / 600kA per phase TPHE120Y30ME 300kA per mode / 600kA per phase TPHE120Y30PP
300kA per mode / 600kA per phase TPHE220Y30ME 300kA per mode / 600kA per phase TPHE220Y30PP
300kA per mode / 600kA per phase TPHE277Y30ME 300kA per mode / 600kA per phase TPHE277Y30PP
300kA per mode / 600kA per phase TPHE480D30ME 300kA per mode / 600kA per phase TPHE480D30PP
300kA per mode / 600kA per phase TPHE347Y30ME 300kA per mode / 600kA per phase TPHE347Y30PP
300kA per mode / 600kA per phase TPHE240H30ME 300kA per mode / 600kA per phase TPHE240H30PP
300kA per mode / 600kA per phase TPHE240D30ME 300kA per mode / 600kA per phase TPHE240D30PP
300kA per mode / 600kA per phase TPHE240Y30ME 300kA per mode / 600kA per phase TPHE240Y30PP

5-6 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Surge Protection Device (SPD) Section 5
Critical Power Products
Integrated Tranquell HE and ME
Designed for GE Distribution Equipment

For GE Switch Gear Distribution Equipment


200 kA Symmetrical Fault Withstand
Panelboard, Lights, Alarm, Surge Counter, Form C Contacts
Maximum Surge Current Product Number
100kA per mode / 200kA per phase TPHE120S10SG
100kA per mode / 200kA per phase TPHE120Y10SG
100kA per mode / 200kA per phase TPHE220Y10SG
100kA per mode / 200kA per phase TPHE277Y10SG
100kA per mode / 200kA per phase TPHE480D10SG
100kA per mode / 200kA per phase TPHE347Y10SG
100kA per mode / 200kA per phase TPHE240H10SG
100kA per mode / 200kA per phase TPHE240D10SG
100kA per mode / 200kA per phase TPHE240Y10SG
150kA per mode / 300kA per phase TPHE120S15SG
150kA per mode / 300kA per phase TPHE120Y15SG
150kA per mode / 300kA per phase TPHE220Y15SG
150kA per mode / 300kA per phase TPHE277Y15SG
150kA per mode / 300kA per phase TPHE480D15SG
150kA per mode / 300kA per phase TPHE347Y15SG
150kA per mode / 300kA per phase TPHE240H15SG
150kA per mode / 300kA per phase TPHE240D15SG
150kA per mode / 300kA per phase TPHE240Y15SG
200kA per mode / 400kA per phase TPHE120S20SG
200kA per mode / 400kA per phase TPHE120Y20SG
200kA per mode / 400kA per phase TPHE220Y20SG
200kA per mode / 400kA per phase TPHE277Y20SG
200kA per mode / 400kA per phase TPHE480D20SG
200kA per mode / 400kA per phase TPHE347Y20SG
200kA per mode / 400kA per phase TPHE240H20SG
200kA per mode / 400kA per phase TPHE240D20SG
200kA per mode / 400kA per phase TPHE240Y20SG
300kA per mode / 600kA per phase TPHE120S30SG
300kA per mode / 600kA per phase TPHE120Y30SG
300kA per mode / 600kA per phase TPHE220Y30SG
300kA per mode / 600kA per phase TPHE277Y30SG
300kA per mode / 600kA per phase TPHE480D30SG
300kA per mode / 600kA per phase TPHE347Y30SG
300kA per mode / 600kA per phase TPHE240H30SG
300kA per mode / 600kA per phase TPHE240D30SG
300kA per mode / 600kA per phase TPHE240Y30SG

* PP suffix available for all kA ratings


* (integral to Spectra panel or switchboard)
Product # SG suffix for all THE devices (100kA - 300kA)
integral to switchgear
ME suffix available for all kA ratings (integral to MCC)

Voltage Protection Rating (VPR) Maximum Surge


UL 1449, 3rd Edition MCOV % Current Capacity
Nominal System Max.
September 2009 Revision Continuous
Voltage Voltage Exposure Level Per Mode Per Phase
Operating
(Volts RMS) Configuration L-N HL-N L-G HL-G N-G L-L Voltage 06 TPME 65kA 130kA
TPHE 120S 120/240 1 Ph, 3 W + G 900 800 700 1200 125% 08 TPME 80KA 160KA
TPME 120Y 120Y/208 3 Ph, 4 W + G 900 800 700 1200 125% 10 TPME 100kA 200kA
220Y 220Y/380 3 Ph, 4 W + G 1500 1200 1200 2000 145% 12 TPHE 125kA 250kA
240D 240 Delta 3 Ph, 3 W + G 1200 1800 196% 15 TPHE 150kA 300kA
240H 120/240 Delta HL 3 Ph, 4 W + G 1000 1200 800 1200 700 2000 115% 20 TPHE 200kA 400kA
240Y 240Y/415 3 Ph, 4 W + G 1500 1200 1200 2000 130% 25 TPHE 250kA 500kA
277Y 277Y/480 3 Ph, 4 W + G 1500 1200 1200 2000 115% 30 TPHE 200kA 400kA
347Y 347Y/600 3 Ph, 4 W + G 1500 1500 1500 2500 115% NOTE: For TVSS field installation kit, add the prefix A
and replace PP suffix with K suffix
480D 480 Delta 3 Ph, 3 W + G 1800 3000 198%
Product # Example
Also available in 600D configurations. For details, please contact GE Power Quality Customer Service at 800 637-1738.
TPHE277Y15PP (factory installed)
ATHE277Y15K (field installation)

Rev. 11/13 www.geindustrial.com BuyLog Catalog 5-7


Data subject to change
without notice
Surge Protection Device (SPD) Section 5
Critical Power Products
Tranquell 9X and 24X
Box Extensions Designed for GE A Series Distribution Equipment

This SPD model is installed in an extended box and connects to


the "A Series" Panelboard without adding width or depth to the
panel enclosure and is ideal for aftermarket installations. These
units have been tested to surge current ratings per NEMA LS-1,
up to 200 kA per mode, including the fuses in the surge path.
Standard features include a surge counter, audible alarm,
indicating lights, dry contacts. Rating options range from 65 kA
per mode to 300 kA per mode.
All mode protection is provided with surge components (MOVs)
connected on the phase-to-neutral, phase-to-ground, and neutral-
to-ground paths as appropriate for the voltage configuration.
Tranquell 9X and 24X products are engineered for reliability,
flexibility and long life in the most extreme surge environments.
The true maximum surge current rating, unlimited by fusing, has
been proven successful in 3rd party tests.

Features and Benefits


UL1449, 3rd Edition
UL Tested to 200,000 Amperes Symmetrical Withstand for 24X
UL Tested to 65,000 Amperes Symmetrical Withstand for 9X
Field Installed with "A Series" panels
Tranquell ME Device is Capable of Surviving a minimum of
5,000 Category C3 Impulses (10kA, 20kV) per mode.
Tranquell HE Device is Capable of Surviving a minimum of
20,000 Category C3 Impulses (10kA, 20kV) per mode.
Device Capable of Surviving a minimum of 5,000 Longwave
(10x1000s) Impulses per mode.
Form C Dry Contacts for Remote Monitoring
Green Status Indicating Lights, Red Service Light
Audible Alarm with Test/Disable Feature
Surge Counter
Standard 5 year limited warranty, Optional 20 year warranty

Specifications
Operating Frequency: 50/60 Hz
Connection: 6 to 2/0 Conductors, Parallel Connected
Operating Temperature: -40C to +65C
Operating Humidity: 0% to 95% Non-Condensing
Weight: 9X - 30 lbs., 12X - 52 lbs.

5-8 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Surge Protection Device (SPD) Section 5
Critical Power Products
Tranquell 9X and 24X
Box Extensions Designed for GE A Series Distribution Equipment
21.500
[546.10] 6.023 20.250 6.023
[152.98] [514.35] [152.984]

9.000
[228.60]
9.000
10.440 [228.6]
[265.18]
9.810
[249.174]

0.042
0.588 [1.067]
[14.94]

1.719 1.719
[43.67] [43.675]
0.344 [8.74] 0.344 [8.738]

7.375
7.375 [187.338]
[187.34] 10.000
10.000 [254]
[254.00] 12.6255
[320.69]
12.625
15.400
[320.69]
[391.16]
15.400
[391.16]

BX9F Dimensions BX9S Dimensions

20.250 6.023
21.500 [514.350] [152.984]
[546.100] 6.023
[152.984]

9.000
9.000 [228.600]
7.042
6.412 [228.600] [178.867]
[162.865] 9.810
10.440 [249.174]
[265.176]

0.588
1.617 2.247 6.609
[14.935]
[41.072] 7.239 [57.074] [167.869]
[183.871] 13.624
14.254 [346.050]
[362.052]

2.389
2.389 [60.693]
[60.693]
0.344 [8.738]

7.375 [8.738] 0.344


7.375
[187.338]
[187.338]
10.000
[254.000] 10.000
12.625 [254.000]
[320.688] 12.625
15.400 [320.688]
[391.160] 15.400
[391.160]

BX9WF Dimensions BX9WS Dimensions

7.085
[179.95] 7.085
6.810 [179.954]
[172.97]
6.333 12.560 5.390 6.333 6.810
0.711 [172.969]
[160.86] [319.02] [136.91] [160.858]
[18.06] 11.940 5.390 0.711
[303.276] [136.906] [18.059]
6.899 6.074
[175.23] [154.28]
8.030 6.074
6.274 8.030
[203.96] 8.635 [154.280]
21.500 [159.360]
[219.33] [203.962] 8.635
[546.10]
[219.329]
20.280 7.624 11.635
[515.11] [193.65] 1.400 20.280 7.624 [295.529]
[35.56] [515.112] [193.650]
1.400
[35.560]

24.000 3.176
[609.60] [80.67] 24.000 3.176
[609.600] [80.672]

7.246 [184.048]
7.246
[184.044]

24.743
[628.47] 24.743
25.440 [628.472]
[646.18]

BX24WF Dimensions BX24WS Dimensions

Rev. 11/13 www.geindustrial.com BuyLog Catalog 5-9


Data subject to change
without notice
Surge Protection Device (SPD) Section 5
Critical Power Products
Tranquell 9X and 24X
Box Extensions Designed for GE A Series Distribution Equipment

Tranquell 9X Box Extensions - 65 kA Symmetrical Fault Withstand


Maximum Surge Current Enclosure Type Description Product Number
9" Box Ext,Flush Mount, Lights, Alarm,
65kA per mode / 130kA per phase A Series Extension Flush Mount TPMEXXXX06BX9F
Counter, Contacts
9" Box Ext,Flush Mount, Lights, Alarm,
80kA per mode / 160kA per phase A Series Extension Flush Mount TPMEXXXX08BX9F
Counter, Contacts
9" Box Ext,Flush Mount, Lights, Alarm,
100kA per mode / 200kA per phase A Series Extension Flush Mount TPMEXXXX10BX9F
Counter, Contacts
9" Box Ext,Flush Mount, DisplayAccess,
65kA per mode / 130kA per phase A Series Extension Flush Mount TPMEXXXX06BX9WF
Lights, Alarm, Counter, Contacts
9" Box Ext,Flush Mount, DisplayAccess,
80kA per mode / 160kA per phase A Series Extension Flush Mount TPMEXXXX08BX9WF
Lights, Alarm, Counter, Contacts
9" Box Ext,Flush Mount, DisplayAccess,
100kA per mode / 200kA per phase A Series Extension Flush Mount TPMEXXXX10BX9WF
Lights, Alarm, Counter, Contacts
9" Box Ext,Surface Mount, Lights, Alarm,
65kA per mode / 130kA per phase A Series Extension Surface Mount TPMEXXXX06BX9S
Counter, Contacts
9" Box Ext,Surface Mount, Lights, Alarm,
80kA per mode / 160kA per phase A Series Extension Surface Mount TPMEXXXX08BX9S
Counter, Contacts
9" Box Ext,Surface Mount, Lights, Alarm,
100kA per mode / 200kA per phase A Series Extension Surface Mount TPMEXXXX10BX9S
Counter, Contacts
9" Box Ext,Surface Mount, Access Display,
65kA per mode / 130kA per phase A Series Extension Surface Mount TPMEXXXX06BX9WS
Lights, Alarm, Counter, Contacts
9" Box Ext,Surface Mount, Access Display,
80kA per mode / 160kA per phase A Series Extension Surface Mount TPMEXXXX08BX9WS
Lights, Alarm, Counter, Contacts
9" Box Ext,Surface Mount, Access Display,
100kA per mode / 200kA per phase A Series Extension Surface Mount TPMEXXXX10BX9WS
Lights, Alarm, Counter, Contacts

Note: Replace XXXX in Product Number with nomenclature for Nominal Voltage (Volts RMS).

Tranquell 24X Box Extensions - 65kA Symmetrical Fault Withstand


Maximum Surge Current Enclosure Type Description Product Number
24" Box Ext,Flush Mount, DisplayAccess,
65kA per mode / 130kA per phase A Series Extension Flush Mount TPMEXXXX06BX24WF
Lights, Alarm, Counter, Contacts
24" Box Ext,Flush Mount, DisplayAccess,
80kA per mode / 160kA per phase A Series Extension Flush Mount TPMEXXXX08BX24WF
Lights, Alarm, Counter, Contacts
24" Box Ext,Flush Mount, DisplayAccess,
100kA per mode / 200kA per phase A Series Extension Flush Mount TPMEXXXX10BX24WF
Lights, Alarm, Counter, Contacts
24" Box Ext,Surface Mount, DisplayAccess,
65kA per mode / 130kA per phase A Series Extension Surface Mount TPMEXXXX06BX24WS
Lights, Alarm, Counter, Contacts
24" Box Ext,Surface Mount, DisplayAccess,
80kA per mode / 160kA per phase A Series Extension Surface Mount TPMEXXXX08BX24WS
Lights, Alarm, Counter, Contacts
24" Box Ext,Surface Mount, DisplayAccess,
100kA per mode / 200kA per phase A Series Extension Surface Mount TPMEXXXX10BX24WS
Lights, Alarm, Counter, Contacts

Note: Replace XXXX in Product Number with nomenclature for Nominal Voltage (Volts RMS).

Tranquell 24X Box Extensions - 200kA Symmetrical Fault Withstand


Maximum Surge Current Enclosure Type Description Product Number
24" Box Ext,Surface Mount, DisplayAccess,
100kA per mode / 200kA per phase A Series Extension Surface Mount TPHEXXXX10BX24WS
Lights, Alarm, Counter, Contacts
24" Box Ext,Surface Mount, DisplayAccess,
150kA per mode / 300kA per phase A Series Extension Surface Mount TPHEXXXX15BX24WS
Lights, Alarm, Counter, Contacts
24" Box Ext,Surface Mount, DisplayAccess,
200kA per mode / 400kA per phase A Series Extension Surface Mount TPHEXXXX20BX24WS
Lights, Alarm, Counter, Contacts
24" Box Ext,Surface Mount, DisplayAccess,
300kA per mode / 600kA per phase A Series Extension Surface Mount TPHEXXXX30BX24WS
Lights, Alarm, Counter, Contacts
24" Box Ext,Flush Mount, DisplayAccess,
100kA per mode / 200kA per phase A Series Extension Flush Mount TPHEXXXX10BX24WF
Lights, Alarm, Counter, Contacts
24" Box Ext,Flush Mount, DisplayAccess,
150kA per mode / 300kA per phase A Series Extension Flush Mount TPHEXXXX15BX24WF
Lights, Alarm, Counter, Contacts
24" Box Ext,Flush Mount, DisplayAccess,
200kA per mode / 400kA per phase A Series Extension Flush Mount TPHEXXXX20BX24WF
Lights, Alarm, Counter, Contacts
24" Box Ext,Flush Mount, DisplayAccess,
300kA per mode / 600kA per phase A Series Extension Flush Mount TPHEXXXX30BX24WF
Lights, Alarm, Counter, Contacts

Note: Replace XXXX in Product Number with nomenclature for Nominal Voltage (Volts RMS).

5-10 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Surge Protection Device (SPD) Section 5
Critical Power Products
Tranquell 9X and 24X
Box Extensions Designed for GE A Series Distribution Equipment

ME Medium Exposure Level

* 9S - Surface mounted, no display


9WS - Surface mounted, display access
9F - Flush mounted , no display
9WF - Flush mounted, display access
Product # T P B X *
ME Medium Exposure &
HE High Exposure Level

* 24WS - Surface mounted, display access


24WF - Flush mounted, display access

MCOV %
Nominal System Max. Maximum Surge
Voltage Voltage
Continuous Current Capacity
Operating
(Volts RMS) Configuration Voltage Exposure
Level Per Mode Per Phase
ME 120S 120/240 1 Ph, 3 W + G 125% 06 ME 65kA 130kA
HE 120Y 120Y/208 3 Ph, 4 W + G 125% 08 ME 80kA 160kA
220Y 220Y/380 3 Ph, 4 W + G 145% 10 ME 100kA 200kA
240D 240 Delta 3 Ph, 3 W + G 115% 12 HE 125kA 250kA
240H 120/240 Delta HL 3 Ph, 4 W + G 115% 15 HE 150kA 300kA
240Y 240Y/415 3 Ph, 4 W + G 130% 20 HE 200kA 400kA
277Y 277Y/480 3 Ph, 4 W + G 115% 25 HE 250kA 500kA
347Y 347Y/600 3 Ph, 4 W + G 115% 30 HE 300kA 600kA
480D 480 Delta 3 Ph, 3 W + G 170%
Phase Rating = (L-N + L-G) Product # Example
Also available in 600D configurations. For details, please TPHE277Y15BX24WF
contact GE Power Quality Customer Service at
277Y/480 V, 3 Ph, 4 W + G
800 637 1738.
150kA per mode
Flush mounted, display access

Voltage Protection Rating (VPR)


UL 1449, 3rd Edition September 2009 Revision
BX9 BX24
L-N HL-N L-G HL-G N-G L-L L-N HL-N L-G HL-G N-G L-L

120S 1500 1500 900 1800 1500 1500 1000 1800


120Y 1500 1500 900 1800 1500 1500 1000 1800
220Y 1800 2000 1500 2500 1800 1800 1500 2500
240D 1800 2500 1800 2500
240H 1500 1800 1500 2000 900 1800 1500 1800 1500 1800 1000 1800
240Y 1800 2000 1500 2500 1800 1800 1500 2500
277Y 1800 2000 1500 2500 1800 1800 1500 2500
347Y 2000 2000 1800 3000 3000 2500 1800 3000
480D 2500 4000 2500 4000

Rev. 11/13 www.geindustrial.com BuyLog Catalog 5-11


Data subject to change
without notice
Surge Protection Device (SPD) Section 5
Critical Power Products
Tranquell HE and ME
Wall Mount

These devices are available in a standard NEMA 12 enclosure.


Optional enclosure types include NEMA 12 and 4X, flushmount,
surface mount and stainless steel. These units have been tested
to surge current ratings per NEMA LS-1, up to 200kA per mode,
including the fuses in the surge path. Standard features include
a surge counter, audible alarm, indicating lights, dry contacts, and
an integral surge rated disconnect (WMN1 and WMN4 only).
Rating options range from 65kA per mode to 300 kA per mode.
All mode protection is provided with surge components (MOVs)
connected on the phase to neutral, phase to ground, and neutral
to ground paths as appropriate for the voltage configuration.
Tranquell HE and ME products are engineered for reliability,
flexibility and long life in the most extreme surge environment.
The true maximum surge current rating, unlimited by fusing, has
been proven successful in 3rd party tests.

Features and Benefits


UL1449, 3rd Edition CUL, UL1283
UL Tested to 200,000 Amperes Symmetrical Withstand
Integral Surge Rated Disconnect
Tranquell ME Device is Capable of Surviving a minimum of
5,000 Category C3 Impulses (10kA, 20kV) per mode.
Tranquell HE Device is Capable of Surviving a minimum of
20,000 Category C3 Impulses (10kA, 20kV) per mode.
Specifications
Device Capable of Surviving a minimum of 5,000 Longwave
Operating Frequency: 50/60 Hz
(10x1000s) Impulses per mode. Connection: 6 to 2/0 Conductors, Parallel Connected
Patented Thermal Fuse Technology in Combination with Surge Operating Temperature: -40C to +65C
Operating Humidity: 0% to 95% Non-Condensing
Rated Fuses Weight: 50 lbs.: (THE), 32 lbs. (TME)
Form C Dry Contacts for Remote Monitoring
*Must be installed downstream from breaker 60 Amp or less.
Green Status Indicating Lights, Red Service Light
Audible Alarm with Test/Disable Feature
Surge Counter
Standard 10 year limited warranty, Optional 20 year warranty
12.000
[304.80]

15.330
[389.38]
0.282 14.759 12.015
[ 7.16] HOLES [374.88] [305.18]
(8 PLACES) 13.478
[342.34]
1.852 0.440
0.571
8.978 [47.04] [14.50] [ 11.18] HOLE
[228.04] (2 PLACES)
0.625
[15.87]
18.759
[476.48]

16.000 19.330
[406.40] [490.98]
15.478
[393.14]

3.852 26.500 24.000


[97.84] [673.10] [609.60]
0.571
[14.50]
1.471
[37.36]
15.330
6.440 [389.38] 0.625
[163.58]
[15.87]

8.978 9.276 1.250


[228.04]
[235.61] [31.75] 0.440
10.750
[273.05] [ 11.18]
(2 PLACES)
12.000 12.000
[304.80] [304.80]

WMN12F Dimensions WMN1 Dimensions

5-12 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Surge Protection Device (SPD) Section 5
Critical Power Products
Tranquell HE and ME
Wall Mount

Wall Mount Tranquell ME - 200kA Symmetrical Fault Withstand Lights, Alarm, Surge Counter, Form C Contacts
Maximum Surge Current Enclosure Type Product Number
65kA per mode / 130kA per phase NEMA 12 Flush TMEXXXX065WMN12F
80kA per mode / 160kA per phase NEMA 12 Flush TMEXXXX080WMN12F
100kA per mode / 200kA per phase NEMA 12 Flush TMEXXXX100WMN12F
65kA per mode / 130kA per phase NEMA 12 Surface, Integral Disconnect TMEXXXX065WMN1
80kA per mode / 160kA per phase NEMA 12 Surface, Integral Disconnect TMEXXXX080WMN1
100kA per mode / 200kA per phase NEMA 12 Surface, Integral Disconnect TMEXXXX100WMN1
65kA per mode / 130kA per phase NEMA 12 Surface TMEXXXX065WMN12S
80kA per mode / 160kA per phase NEMA 12 Surface TMEXXXX080WMN12S
100kA per mode / 200kA per phase NEMA 12 Surface TMEXXXX100WMN12S
65kA per mode / 130kA per phase NEMA 4 Painted Steel Surface TMEXXXX065WMN4S
80kA per mode / 160kA per phase NEMA 4 Painted Steel Surface TMEXXXX080WMN4S
100kA per mode / 200kA per phase NEMA 4 Painted Steel Surface TMEXXXX100WMN4S
65kA per mode / 130kA per phase NEMA 4X Fiberglass, Integral Disconnect TMEXXXX065WMN4
80kA per mode / 160kA per phase NEMA 4X Fiberglass, Integral Disconnect TMEXXXX080WMN4
100kA per mode / 200kA per phase NEMA 4X Fiberglass, Integral Disconnect TMEXXXX100WMN4
65kA per mode / 130kA per phase NEMA 4X Stainless Steel TMEXXXX065WMN4X
80kA per mode / 160kA per phase NEMA 4X Stainless Steel TMEXXXX080WMN4X
100kA per mode / 200kA per phase NEMA 4X Stainless Steel TMEXXXX100WMN4X

Note: Replace XXXX in Product Number with nomenclature for Nominal Voltage (Volts RMS).

Wall Mount Tranquell HE - 200kA Symmetrical Fault Withstand Lights, Alarm, Surge Counter, Form C Contacts
Maximum Surge Current Enclosure Type Product Number
100kA per mode / 200kA per phase NEMA 12 Flush THEXXXX100WMN12F
150kA per mode / 300kA per phase NEMA 12 Flush THEXXXX150WMN12F
200kA per mode / 400kA per phase NEMA 12 Flush THEXXXX200WMN12F
300kA per mode / 600kA per phase NEMA 12 Flush THEXXXX300WMN12F
100kA per mode / 200kA per phase NEMA 12 Surface, Integral Disconnect THEXXXX100WMN1
150kA per mode / 300kA per phase NEMA 12 Surface, Integral Disconnect THEXXXX150WMN1
200kA per mode / 400kA per phase NEMA 12 Surface, Integral Disconnect THEXXXX200WMN1
300kA per mode / 600kA per phase NEMA 12 Surface, Integral Disconnect THEXXXX300WMN1
100kA per mode / 200kA per phase NEMA 12 Surface THEXXXX100WMN12S
150kA per mode / 300kA per phase NEMA 12 Surface THEXXXX150WMN12S
200kA per mode / 400kA per phase NEMA 12 Surface THEXXXX200WMN12S
300kA per mode / 600kA per phase NEMA 12 Surface THEXXXX300WMN12S
100kA per mode / 200kA per phase NEMA 4 Painted Steel Surface THEXXXX100WMN4S
150kA per mode / 300kA per phase NEMA 4 Painted Steel Surface THEXXXX150WMN4S
200kA per mode / 400kA per phase NEMA 4 Painted Steel Surface THEXXXX200WMN4S
300kA per mode / 600kA per phase NEMA 4 Painted Steel Surface THEXXXX300WMN4S
100kA per mode / 200kA per phase NEMA 4X Fiberglass, Integral Disconnect THEXXXX100WMN4
150kA per mode / 300kA per phase NEMA 4X Fiberglass, Integral Disconnect THEXXXX150WMN4
200kA per mode / 400kA per phase NEMA 4X Fiberglass, Integral Disconnect THEXXXX200WMN4
300kA per mode / 600kA per phase NEMA 4X Fiberglass, Integral Disconnect THEXXXX300WMN4
100kA per mode / 200kA per phase NEMA 4X Stainless Steel THEXXXX100WMN4X
150kA per mode / 300kA per phase NEMA 4X Stainless Steel THEXXXX150WMN4X
200kA per mode / 400kA per phase NEMA 4X Stainless Steel THEXXXX200WMN4X
300kA per mode / 600kA per phase NEMA 4X Stainless Steel THEXXXX300WMN4X

Note: Replace XXXX in Product Number with nomenclature for Nominal Voltage (Volts RMS).

Rev. 11/13 www.geindustrial.com BuyLog Catalog 5-13


Data subject to change
without notice
Surge Protection Device (SPD) Section 5
Critical Power Products
Tranquell HE and ME
Wall Mount

Product # WM N

Voltage Protection Rating (VPR)


UL 1449, 3rd Edition MCOV %
Nominal System Max.
September 2009 Revision Continuous
Voltage Voltage Maximum Surge
Operating
(Volts RMS) Configuration LN HLN LG HLG NG L-L HL-L Voltage Current Capacity
Exposure Per Per
THE 120S 120/240 1 Ph, 3W + G 1000 1000 700 1200 - 125% Level Mode Phase
TME 120Y 120Y/208 3 Ph, 4W + G 1000 1000 - 700 1200 125% 065 ME 65kA 130kA
220Y 220Y/380 3 Ph, 4W + G 1500 1500 1000 2000 145% 080 ME 80kA 160kA
240D 240 Delta 3 Ph, 4W 1500 1800 196% 100 ME 100kA 200kA
240H 120/240 Delta HL 3 Ph, 4W + G 1000 1500 1000 1500 700 1200 2500 115% 125 HE 125kA 250kA
240Y 240Y/415 3 Ph, 4W + G 1500 1500 1000 2000 130% 150 HE 150kA 300kA
277Y 277Y/480 3 Ph, 4W + G 1500 1500 1000 2000 115% 200 HE 200kA 400kA
347Y 347Y/600 3 Ph, 4W + G 1800 1500 1500 2500 115% 250 HE 250kA 500kA
480D 480 Delta 3 Ph, 4W 2000 4000 198% 300 HE 300kA 600kA

NEMA
Suffix Description Enclosure Mounting Disconnect
1 Painted Steel 1 Surface Yes
12S Painted Steel 12 Surface No
Product # Example
THE277Y150WMN12S 12F Painted Steel 12 Flush No
4 Fiberglass 4X Surface Yes
4S Painted Steel 4 Surface No
4X Stainless Steel 4X Surface No

5-14 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Surge Protection Device (SPD) Section 5
Critical Power Products
Tranquell HE and ME
Wall Mount, with Enhanced Thermal Protection

Introduction
Recommended installation locations are primary and secondary
distribution and point of use levels. Designed for distribution and
point of use locations, but rated for service entrance, the
Tranquell HE and ME with enhanced thermal protection has
been third-party tested to ANSI/IEEE C3 10kA 8x20s impulses.
The entire Tranquell HE and ME line-up has been engineered to
the highest standards and is designed for rigorous duty and long
life, as evidenced in our outstanding minimum repetitive surge
current capacity test results.
These devices are available in a standard NEMA 12 enclosure.
Optional enclosure types from NEMA 12 NEMA 4x include flush
mount, surface mount, fiberglass and stainless steel.
These units have been tested to surge current ratings per NEMA
LS-1, up to 200kA per mode, 400kA per phase. Standard features
include a surge counter, audible alarm, indicating lights, dry
contacts, and an integral surge rated disconnect. Rating options
Specifications
range from 65kA 300kA per mode, 130kA 600kA per phase.
Operating Frequency 50/60 Hz
GE engineers design and build transient voltage surge suppres- Connection 6 to 2/0 Conductors, Parallel Connected
sors in our state-of-the-art lab and production facilities. Extensive Operating Temperature -40 F to 140 F (-40 C to +65 C)
testing is performed at GE and third-party test labs across North Operating Humidity 0% to 95% Non-Condensing
America. Production is carried out at our factory in Bonham, Texas
Weight NEMA Enclosure Suffix:
utilizing Six Sigma, ISO 9001 methodologies and lean
1 63 lbs. (28.5 kg)
manufacturing processes.
4 56 lbs. (25.4 kg)
4S, 12S, 12F 44 lbs. (20.0 kg)
4X 50 lbs. (22.7 kg)
Features and Benefits
UL 1449 3rd Edition, September 2009, cUL
UL 1283 noise filtering. The TVSS device EMI-RFI noise rejection
or attenuation value is measured in accordance with the
procedures outlined in NEMA LS 1-1992 (R2000)/MILSTD-220B.
Attenuation is -50db minimum @ 100kHz.
UL tested to 200,000 amperes symmetrical withstand
Integral surge rated disconnect
Tranquell ME device is capable of surviving a minimum of
5,000 category C3 impulses (10kA, 20kV) per mode
Tranquell HE device is capable of surviving a minimum of
20,000 category C3 impulses (10kA, 20kV) per mode
Thermally protected MOVS eliminate the need for additional
upstream fuses
NO/NC Form C dry type contacts for remote monitoring
Green status indicating lights, red service light
Audible alarm with test/disable feature
Standard LCD surge counter
10 year limited warranty (standard),
20 year limited warranty (optional)

Rev. 11/13 www.geindustrial.com BuyLog Catalog 5-15


Data subject to change
without notice
Surge Protection Device (SPD) Section 5
Critical Power Products
Tranquell HE and ME
Wall Mount, with Enhanced Thermal Protection

12.000
[304.80] 20.000
[508.00]

12.015
[305.18] 12.651
[321.34]
0.440
[ 11.18] HOLE
(2 PLACES)
0.625
[15.87]

26.500 24.000
[673.10] [609.60]
24.000 25.500
[609.60] [647.70]

0.625
[15.87]

9.276 1.250
[235.61] [31.75] 0.440
10.750
[273.05] [ 11.18]
(2 PLACES)
12.000 9.912 21.500
[251.76] [546.10]
[304.80]

WMN1 Dimensions WMN4 Dimensions

15.330
0.380
[389.38] [ 9.65] HOLE
14.759 (4 PLACES)
0.282
[ 7.16] HOLES [374.88] 9.226 10.399
(8 PLACES) 13.478 [234.33] [264.14]
[342.34]
1.852 0.571
8.978 [47.04] [14.50]
[228.04]

18.759
[476.48]

19.118 17.659
19.330
[485.61] [448.53]
16.000
[406.40] [490.98]
15.478
[393.14]

3.852
[97.84]

0.571
[14.50]
1.471
[37.36]
1.475
15.330 [37.46]
6.440 [389.38] 11.999
[163.58] 6.439 [304.77]
[163.56]

8.978
[228.04]
9.226
[234.33]
12.000
[304.80]

WMN12F Dimensions WMN12S, WMN4S, WMN4X Dimensions

Wall Mount Tranquell ME - 200kA Symmetrical Fault Withstand Lights, Alarm, Surge Counter, Form C Contacts
Maximum Surge Current Enclosure Type Product Number
65kA per mode / 130kA per phase NEMA 12 Flush TPMEXXXX06WMN12F
80kA per mode / 160kA per phase NEMA 12 Flush TPMEXXXX08WMN12F
100kA per mode / 200kA per phase NEMA 12 Flush TPMEXXXX10WMN12F
65kA per mode / 130kA per phase NEMA 12 Surface, Integral Disconnect TPMEXXXX06WMN1
80kA per mode / 160kA per phase NEMA 12 Surface, Integral Disconnect TPMEXXXX08WMN1
100kA per mode / 200kA per phase NEMA 12 Surface, Integral Disconnect TPMEXXXX10WMN1
65kA per mode / 130kA per phase NEMA 12 Surface TPMEXXXX06WMN12S
80kA per mode / 160kA per phase NEMA 12 Surface TPMEXXXX08WMN12S
100kA per mode / 200kA per phase NEMA 12 Surface TPMEXXXX10WMN12S
65kA per mode / 130kA per phase NEMA 4 Painted Steel Surface TPMEXXXX06WMN4S
80kA per mode / 160kA per phase NEMA 4 Painted Steel Surface TPMEXXXX08WMN4S
100kA per mode / 200kA per phase NEMA 4 Painted Steel Surface TPMEXXXX10WMN4S
65kA per mode / 130kA per phase NEMA 4X Fiberglass, Integral Disconnect TPMEXXXX06WMN4
80kA per mode / 160kA per phase NEMA 4X Fiberglass, Integral Disconnect TPMEXXXX08WMN4
100kA per mode / 200kA per phase NEMA 4X Fiberglass, Integral Disconnect TPMEXXXX10WMN4
65kA per mode / 130kA per phase NEMA 4X Stainless Steel TPMEXXXX06WMN4X
80kA per mode / 160kA per phase NEMA 4X Stainless Steel TPMEXXXX08WMN4X
100kA per mode / 200kA per phase NEMA 4X Stainless Steel TPMEXXXX10WMN4X

Note: Replace XXXX in Product Number with nomenclature for Nominal Voltage (Volts RMS).

5-16 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Surge Protection Device (SPD) Section 5
Critical Power Products
Tranquell HE and ME
Wall Mount, with Enhanced Thermal Protection

Wall Mount Tranquell HE - 200kA Symmetrical Fault Withstand Lights, Alarm, Surge Counter, Form C Contacts
Maximum Surge Current Enclosure Type Product Number
100kA per mode / 200kA per phase NEMA 12 Flush TPHEXXXX10WMN12F
150kA per mode / 300kA per phase NEMA 12 Flush TPHEXXXX15WMN12F
200kA per mode / 400kA per phase NEMA 12 Flush TPHEXXXX20WMN12F
300kA per mode / 600kA per phase NEMA 12 Flush TPHEXXXX30WMN12F
100kA per mode / 200kA per phase NEMA 12 Surface, Integral Disconnect TPHEXXXX10WMN1
150kA per mode / 300kA per phase NEMA 12 Surface, Integral Disconnect TPHEXXXX15WMN1
200kA per mode / 400kA per phase NEMA 12 Surface, Integral Disconnect TPHEXXXX20WMN1
300kA per mode / 600kA per phase NEMA 12 Surface, Integral Disconnect TPHEXXXX30WMN1
100kA per mode / 200kA per phase NEMA 12 Surface TPHEXXXX10WMN12S
150kA per mode / 300kA per phase NEMA 12 Surface TPHEXXXX15WMN12S
200kA per mode / 400kA per phase NEMA 12 Surface TPHEXXXX20WMN12S
300kA per mode / 600kA per phase NEMA 12 Surface TPHEXXXX30WMN12S
100kA per mode / 200kA per phase NEMA 4 Painted Steel Surface TPHEXXXX10WMN4S
150kA per mode / 300kA per phase NEMA 4 Painted Steel Surface TPHEXXXX15WMN4S
200kA per mode / 400kA per phase NEMA 4 Painted Steel Surface TPHEXXXX20WMN4S
300kA per mode / 600kA per phase NEMA 4 Painted Steel Surface TPHEXXXX30WMN4S
100kA per mode / 200kA per phase NEMA 4X Fiberglass, Integral Disconnect TPHEXXXX10WMN4
150kA per mode / 300kA per phase NEMA 4X Fiberglass, Integral Disconnect TPHEXXXX15WMN4
200kA per mode / 400kA per phase NEMA 4X Fiberglass, Integral Disconnect TPHEXXXX20WMN4
300kA per mode / 600kA per phase NEMA 4X Fiberglass, Integral Disconnect TPHEXXXX30WMN4
100kA per mode / 200kA per phase NEMA 4X Stainless Steel TPHEXXXX10WMN4X
150kA per mode / 300kA per phase NEMA 4X Stainless Steel TPHEXXXX15WMN4X
200kA per mode / 400kA per phase NEMA 4X Stainless Steel TPHEXXXX20WMN4X
300kA per mode / 600kA per phase NEMA 4X Stainless Steel TPHEXXXX30WMN4X

Note: Replace XXXX in Product Number with nomenclature for Nominal Voltage (Volts RMS).

Product # T P W M N

Voltage Protection Rating (VPR)


UL 1449, 3rd Edition MCOV %
Nominal System Max.
September 2009 Continuous
Voltage Voltage Maximum Surge
Operating
(Volts RMS) Configuration LN HLN LG HLG NG LL HLL Voltage Current Capacity

ME 120S 120/240 1 Ph, 3W + G 900 800 700 1200 125% Exposure Level Per Mode Per Phase

HE 120Y 120Y/208 3 Ph, 4W + G 900 800 700 1200 125% 06 ME 65kA 130kA
220Y 220Y/380 3 Ph, 4W + G 1500 1200 1200 2000 145% 08 ME 80kA 160kA
240D 240 Delta 3 Ph, 4W 1200 1800 196% 10 ME 100kA 200kA
240H 120/240 Delta HL 3 Ph, 4W + G 1000 1200 800 1200 700 2000 2200 115% 12 HE 125kA 250kA
240Y 240Y/415 3 Ph, 4W + G 1500 1200 1200 2000 130% 15 HE 150kA 300kA
277Y 277Y/480 3 Ph, 4W + G 1500 1200 1200 2000 115% 20 HE 200kA 400kA
347Y 347Y/600 3 Ph, 4W + G 1500 ---- 1500 ---- 1500 2500 ---- 115% 25 HE 250kA 500kA
480D 480 Delta 3 Ph, 4W ---- ---- 1800 ---- ---- 3000 ---- 198% 30 HE 300kA 600kA
Phase Rating = (L-N + L-G)
Also available in 600D configurations. For details, please contact GE Power Quality
Customer Service at 800 637 1738.

Product # Example
TPHE277Y15WMN12S
277Y/480 V, 3 Ph, 4 W + G NEMA
Suffix Description Mounting Disconnect
150kA per mode Enclosure
Surface mount enclosure 1 Painted Steel 1 Surface Yes
without disconnect 12S Painted Steel 12 Surface No
Painted steel 12F Painted Steel 12 Flush No
4 Fiberglass 4X Surface Yes
4S Painted Steel 4 Surface No
4X Stainless Steel 4X Surface No

Rev. 11/13 www.geindustrial.com BuyLog Catalog 5-17


Data subject to change
without notice
Surge Protection Device (SPD) Section 5
Critical Power Products
Tranquell ME and LE
Wall Mount

The Tranquell ME and LE feature compact, economical, universal


designs for use at medium exposure, distribution or branch
panels and are available in a standard NEMA 12 enclosure. These
devices have been tested to surge current ratings per NEMA LS-1,
including the fuses in the surge path. These units come standard
with indicating lights and dry contacts. Ratings are available from
25kA per mode to 100kA per mode.
These surge protection devices provide all mode protection, with
surge components (MOVs) connected on the phase- to-neutral,
phase-to-ground, and neutral-to-ground paths as appropriate for
the voltage configuration.

Features and Benefits


Universal design allows for easy retrofit installation
UL1449, 3rd Edition cUL
Tranquell ME devices with UL1283 Noise Filters
UL Tested to 65,000 Amperes Symmetrical Withstand
Tranquell ME Device is Capable of Surviving a minimum of
5,000 Category C3 Impulses (10kA, 20kV) per mode
Tranquell ME Device Capable of Surviving a minimum of 5,000
Longwave (10x1000ms) Impulses per mode
Tranquell LE Device is Capable of Surviving a minimum of
3,500 Category C3 Impulses (10kA, 20kV) per mode
Form C Dry Contacts for Remote Monitoring
Green Status Indicating Light(s)
Standard 10 year limited warranty, Optional 20 year warranty

Specifications
Operating Frequency: 50/60 Hz
Connection: 10 AWG Conductors, Parallel Connected
Operating Temperature: -40C to +65C
Operating Humidity: 0% to 95% Non-Condensing
Weight: (TME) 19 lbs., (TLE) 11.4 lbs.

*Must be installed downstream from 60 Amp breaker or less.

TME TLE
4.00

3/4" N.P.T.
6.75

6.25
7.50

6.25

4.37
2.85
1.55

6.00

5-18 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Surge Protection Device (SPD) Section 5
Critical Power Products
Tranquell ME and LE
Wall Mount

Wall Mount Tranquell ME and LE - 65 kA Symmetrical Fault Withstand


Maximum Surge Current Enclosure Type Description Product Number
25 kA per mode / 50 kA per phase NEMA 12 Lights, Form C Contacts TLEXXXX025WM
50 kA per mode / 100 kA per phase NEMA 12 Lights, Form C Contacts TLEXXXX050WM
65 kA per mode / 130 kA per phase NEMA 12 Lights, Form C Contacts TMEXXXX065WM
80 kA per mode / 160 kA per phase NEMA 12 Lights, Form C Contacts TMEXXXX080WM
100 kA per mode / 200 kA per phase NEMA 12 Lights, Form C Contacts TMEXXXX100WM

Note: Replace XXXX in Product Number with nomenclature for Nominal Voltage (Volts RMS).

* Voltage Protection Rating, UL1449, 3rd Edition


** Maximum Continuous Operating Voltage

Product # WM

TLE Voltage Protection Rating (VPR)


UL 1449, 3rd Edition MCOV %
Nominal System Max.
September 2009 Continuous
Voltage Voltage Operating
(Volts RMS) Configuration LN HLN LG HLG NG LL HLL Voltage

TLE 120S 120/240 1 Ph, 3W + G 600 600 600 1000 125%


TME 120Y 120Y/208 3 Ph, 4W + G 600 600 600 1000 125%
220Y 220Y/380 3 Ph, 4W + G 1200 1000 1200 1800 145%
240D 240 Delta 3 Ph, 4W 900 1800 196%
240H 120/240 Delta HL 3 Ph, 4W + G 600 1200 600 1000 600 1000 1800 115%
240Y 240Y/415 3 Ph, 4W + G 1200 1000 1200 1800 130%
277Y 277Y/480 3 Ph, 4W + G 1200 1000 1200 1800 115%
480D 480 Delta 3 Ph, 4W 1800 4000 198%

025 25kA per mode 50 kA per phase (TLE)


050 50kA per mode 100 kA per phase (TLE)
065 65 kA per mode 130 kA per phase (TME)
080 80 kA per mode 160 kA per phas e (TME)
100 100 kA per mode 200 kA per phase (TME)

Rev. 11/13 www.geindustrial.com BuyLog Catalog 5-19


Data subject to change
without notice
Surge Protection Device (SPD) Section 5
Critical Power Products
Tranquell DIN Rail Mount

The full-featured Tranquell DIN Rail Mount SPD (Surge Protection


Device) is a Type 2 surge protection device that is modular and
easy to install. DIN Rail mount housing allows for quick installa-
tion. Each unit has a compact footprint and user-replaceable
phase surge pluggable modules with an IP20 finger-safe design.
Both visual indicators and remote indicators (dry contact) provide
SPD status to critical control circuits.

Features and Benefits


Built-in thermal protection
200kA interrupting rated
DIN Rail mount
Pluggable modules, finger-safe design IP20 rating
Dimensional Diagrams
Built-in visual status indicator
3.89 Poles A
Remote indicator with 3 pin COM/NO/NC contacts 98.9
1-Pole 0.71 in [18 mm]
.35
Easy installation or retrofit 8.9 2-Pole 1.42 in [36 mm]
.60 3-Pole 2.13 in [54 mm]
Fail-safe / self-protected design .70
15.2
4-Pole 2.84 in [72 mm]
17.8
Small footprint A

No external fusing or circuit breakers required


Standard 5 year limited warranty, optional 20 year warranty
.15
3.9

Specifications
UL1449, 3rd edition (September 2009) 2.00
2.82
71.8
50.7
UL type 2 device Microswitch

RoHS compliant .44


11.1
ANSI/IEEE C62.41 NOTE:
All dimensions in the diagram above are for reference only
and are shown in Inches [millimeters]

5-20 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Surge Protection Device (SPD) Section 5
Critical Power Products
Tranquell DIN Rail Mount

Product Numbers and Specifications


Product Configuration UL Specifications Voltage Protection Rating (VPR) (Up @ In)
Nominal
Nominal Max Discharge Electrical Discharge
Voltage No. of Current (Imax, Wiring Voltage Current MCOV MCOV MCOV
Product Number (50/60 Hz) Wires 8/20 s, kA) Configuration* Configuration** (In, kA) (Vc) L-L (Vc) L-G (Vc) L-N L-N L-G N-G L-L H-L1 H-N H-G
TD120Y4025RMN 25kA 20 360 360 180 600 1200 600 1200

120 / 208V
TD120Y4050RMN 50kA 20 360 360 180 600 1200 600 1200
TD277Y4025RMN 25kA 3 Phase Wye, 20 640 500 320 1000 1500 600 1800
277 / 480V Figure C
TD277Y4050RMN 50kA plus N-G 20 640 500 320 1000 1500 600 1800
TD347Y4025RMN 5-Wire / 25kA 10 840 695 420 1500 2000 900 2500
347 / 600V
TD347Y4050RMN 4 Pole 50kA 10 840 695 420 1500 2000 900 2500
TD240H4025RMN 25kA 20 600 1200 600 1200 1500 900 1500
120 / 240V 3 Phase
TD240H4050RMN 50kA 20 600 1200 600 1200 1500 900 1500
High Leg Figure E ***
TD480H4025RMN 25kA 10 900 1500 600 1800 2500 1800 2000
240 / 480V Delta
TD480H4050RMN 50kA 10 900 1500 600 1800 2500 1800 2000
TD120Y3025RMP 25kA 20 360 180 600 1200
120 / 208V
TD120Y3050RMP 50kA 20 360 180 600 1200
TD277Y3025RMP 25kA 3 Phase Wye, 20 640 320 1000 1800
277 / 480V Figure C
TD277Y3050RMP 50kA common N/G 20 640 320 1000 1800
TD347Y3025RMP 4-Wire / 25kA 10 840 420 1500 2500
347 / 600V
TD347Y3050RMP 3 Pole 50kA 10 840 420 1500 2500
TD240D3025RMP 25kA 20 550 275 900 1800
240V
TD240D3050RMP 50kA 20 550 275 900 1800
3 Phase Delta Figure D
TD480D3025RMP 25kA 10 1100 550 1800 3000
480V
TD480D3050RMP 50kA 10 1100 550 1800 3000
TD120S2025RMP 120 / 208V, 25kA 20 360 180 600 1200
TD120S2050RMP 120 / 240V 3 Wire / 50kA 20 360 180 600 1200
Split Phase Figure B
TD240S2025RMP 2 Pole 25kA 20 550 275 900 1800
240 / 480V
TD240S2050RMP 50kA 20 550 275 900 1800
TD120S1025RMP 25kA 20 180 600
120V
TD120S1050RMP 50kA 20 180 600
TD240S1025RMP 25kA 20 275 900
240V
TD240S1050RMP 2 Wire / 50kA 20 275 900
Single Phase Figure A
TD277S1025RMP 1 Pole 25kA 20 320 1000
277V
TD277S1050RMP 50kA 20 320 1000
TD347S1025RMP 25kA 10 420 1500
347V
TD347S1050RMP 50kA 10 420 1500

***Please contact the factory for details

**Wiring
Wiring Configuration
Configuration Diagrams
Diagrams (NOTE: Shown(NOTE
with no power applied)
: Shown with no power applied)
SINGLE SPLIT 3 PHASE DELTA / 3 PHASE HIGH LEG DELTA /
PHASE PHASE 3 PHASE WYE, COMMON N/G 3 PHASE WYE, PLUS N-G
L L1 L2 L1 L2 L3 L1 L2 L3

G/N
G/N G/N
N

**Electrical
** ElectricalVoltage Configurations
Voltage Configurations
L L1 L1 L1 L3 NOTE: GEs Tranquell Series SPD
DIN Rail mount devices are tested
L2
N
N for safe operation without any
N dedicated overcurrent protection,
L2 L1 when correctly matched to the
N L2 L3 L2 power system parameters.
L3
G G G G A gG 160 Amp NH Fuse may be
chosen to meet other requirements
FIGURE A FIGURE B FIGURE C FIGURE D FIGURE E in an IEC application. Consult local
Single Phase Split Phase 3 Phase Wye 3 Phase Delta 3 Phase Delta Hi-Leg codes and standards for appropriate
2 Wire + Ground 3 Wire + Ground 4 Wire + Ground 3 Wire + Ground 4 Wire + Ground fuse sizing.

Rev. 11/13 www.geindustrial.com BuyLog Catalog 5-21


Data subject to change
without notice
Surge Protection Device (SPD) Section 5
Critical Power Products
Protection Block AssemblySurge Protection Device

Introduction
The GE 427 patented 5 Pin Protection Block Assembly is equipped
with a multi-layered printed circuit board, providing a connector-
ized interface for cable assemblies. It accommodates 25, 50 or
100 pair cable. It is used in many applications, including: central
offices, remote switching sites, customer premises and building
entrances, to protect telephone and voice/data lines.
When wiring cabinets with conventional wire wrap blocks each
block becomes a different part number and causes difficulty for
OEMs who have to inventory parts.
The same GE 427 Protection Block Assembly is used in every
position of a cabinet or mainframe. The cables are now treated as
less expensive parts and are stocked by length and mating con-
nector type. Manual labor, in running cables and making Protection Block Assembly
wire wrap connections, is reduced significantly by employing
GE Connectorized Block Assemblies.

Performance Features Protection Block AssemblySurge Protection Device


Gold pins and sockets ensure proper electrical connections Product
Pair Block Type Hood Number
Self-locking aluminum hood (optional) provides protection to
50 Marconi Block YES 427-050-202
connectors and printed circuit board and serves as the cable
100 Avaya Block YES 427-100-102
strain relief tie point
100 Marconi Block YES 427-100-202
Multi-layered printed circuit board
100 Corning Block YES 427-100-302
Handle heavy transient current surges
U.S. Patent No. 5,457,593

Benefits
Provides maximum reliability by eliminating all wire wraps
Provides the high quality installation of a protection block
Provides additional flexibility for equipment installations
Easily serviceable in the field
Eliminates the need for wire wrapping
Allows connectorization into many different applications and
greatly reduces installation, labor and repair costs
All cables connected to this unit can be removed, permitting
specific cable change out or change out of the entire protection
block assembly. This allows the protected equipment to quickly
be put back into service.
Covered by a two year limited product warranty

Specifications
Voltage Class: 600 V
BIL rating: 10 kV
Primary Currents: 10 to 5000 amps

5-22 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Section Updated 09 / 2016

Molded Case Circuit Breakers Section 6

Industrial Circuit Breakers Record Plus


How to Order................................................................................................6-2 15-100A, FB Line ......................................................................................6-69
Features ..........................................................................................................6-4 FB Internal Accessories.........................................................................6-73
Quick Reference Guide ............................................................................6-6 FB External Accessories........................................................................6-74
Q-Line Circuit Breakers 15-100A, FC Line......................................................................................6-75
Plug-In 120/240V Class.........................................................................6-14 FC Internal Accessories.........................................................................6-78
Plug-In 240V Class ..................................................................................6-16 FC External Accessories........................................................................6-79
Bolt-On 240V Class .................................................................................6-20 25-250A, FE Line ......................................................................................6-80
Cable-In Cable Out (lug-lug) 240V Class.......................................6-25 FE Internal Accessories.........................................................................6-82
DIN-Rail Mount 240V Class .................................................................6-27 FE External Accessories........................................................................6-82
Cable-In Cable Out (lug-lug) 240V Class.......................................6-28 100-600A, FG Line...................................................................................6-84
Molded Case Switches 240V Class..................................................6-29 FG with PremEon S................................................................................6-85
Accessories 240V Class ........................................................................6-30 FG with SMR2 ...........................................................................................6-86
Thermal Magnetic Trip FG Internal Accessories ........................................................................6-88
15-100A Type TEY/TEYF Bolt-On ......................................................6-32 FG External Accessories .......................................................................6-89
15-125A Type TEYD/TEYH/TEYL ........................................................6-33 Molded Case Switches 100-1200 A ......................................6-90
10-150A E-150 Line Types TEB, TED, THED ................................6-35 Motor Circuit Protectors
200-600A J600 Line Types TJJ, TJK, THJK....................................6-37 3-250A Spectra RMS Mag Break....................................................6-91
Internal Accessories Molded Case Circuit Breakers 125-1200A Spectra RMS Mag Break............................................6-92
Accessory Devices and Ratings........................................................6-39 25-600A Record Plus Mag Break......................................................6-93
Auxiliary Switches....................................................................................6-40 External Accessories
Shunt Trip ....................................................................................................6-41 Cable Operators .......................................................................................6-94
Undervoltage Release ...........................................................................6-43 Flange-Mounted Operators ................................................................6-96
Spectra RMS Door Mounted Operators.....................................................................6-98
15-150A, SE150 Frame .........................................................................6-45 Motor Operators and Plug-in Hardware....................................6-100
70-250A, SF250 Frame .........................................................................6-47 Mechanical Interlocks and Locking Devices............................6-101
125-600A, SG600 Frame......................................................................6-49 Breaker Mounting Hardware and Kits ........................................6-102
300-1200A, SK1200 Frame.................................................................6-52 Lugs and Associated Hardware.....................................................6-103
Spectra RMS with microEntelliGuard Trip Unit Neutral Grounds and Sensors.........................................................6-105
Features .......................................................................................................6-54 Plug-in Hardware ..................................................................................6-106
microEntelliGuard Trip Unit Characteristics .............................6-55
How to Order .............................................................................................6-56
60-600A, SG600 Line..............................................................................6-58
300-1200A, SK1200 Line......................................................................6-60
Accessories for Spectra RMS Circuit Breakers with
microEntellGuard Trip Units
Power Management System Accessories....................................6-62
Other Accessories....................................................................................6-66
Internal Accessories ...............................................................................6-67

Rev. 11/13 www.geindustrial.com BuyLog Catalog 6-1


Data subject to change
without notice
Molded Case Circuit Breakers Section 6
Industrial Circuit Breakers

How to Order
Q-Line
Thermal Magnetic Circuit Breakers
Molded-Case Switches
The product number as shown in the following pages includes the
complete breaker or switch. TQD and TJD breakers are complete
with Cu/Al line and load lugs.
E 150 Line
Thermal Magnetic Circuit Breakers
Magnetic Circuit Breakers
Molded Case Switches
The product numbers as shown in the following pages include the
complete breaker or switch. All devices listed come with Cu/Al line
and load lugs. If line lugs are not required on a breaker, eliminate
WL from product number; for molded case switches see page
6-3. Unless otherwise noted, all circuit breakers are UL listed in
File E11592. Molded case switches are UL listed in File E57546.
J 600 Line
Thermal Magnetic Circuit Breakers
Magnetic Circuit Breakers
Molded Case Switches Q-Line Thermal Magnetic Circuit Breakers
These breakers are available with either noninterchangeable trip and Molded-Case Switches
(designated Type TJJ) or interchangeable trip (designated Type
TJK and THJK). Type TJJ product numbers include frame, trip,
Cu/Al line, and load lugs factory assembled. If line lugs are not
required on the breaker, eliminate WL from product number, and
Tri-Break Line
subtract price of line lugs from price of complete breaker.
Integrally Fused Thermal Magnetic Circuit Breakers
TJK breakers are available in two frames, 400 ampere frame Integrally Fused Magnetic Circuit Breakers
(125 to 400 amperes) and 600 ampere frame (250 to 600 Integrally Fused Molded Case Switches
amperes). Trip units are not interchangeable between frames.
These breakers are available in three types. Type TB1 (15-100
Complete Circuit Breaker price includes frame, trip unit, Cu/Al amperes) product numbers include frame, trip, line and load
line, and load lugs. Unit will be shipped unassembled unless order lugs, and current limiters all factory assembled. TB6 (300 to 600
specifies must be factory assembled. If line lugs are not amperes) and TB8 (600 to 800 amperes) include frame, trip and
required, eliminate WL from product number and subtract price limiters, factory assembled, but do not include line or load lugs.
of line lugs from price of complete breaker. If line and load lugs are required, order separately. Unless other-
To order the frame, trip, and lugs separately, select the required wise noted, TB1, TB6, and TB8 breaker components are UL
components from table. Magnetic breakers must be ordered as listed in File E42263. Fused molded case switches are UL
components. A complete breaker consists of frame, trip, and one listed in File E57546.
line and one load lug per pole. Mag-Break Line
Price of ordering Complete Circuit Breaker vs. frame, trip, and Magnetic only circuit breakers (motor circuit protectors)
line and load lugs separately is the same. These breakers are available only with noninterchangeable
Molded case switches can also be ordered as complete units adjustable magnetic trip, in frame Types E, F, J, K, and Tri-Break.
(designated Type TJK---Y) or as separate components. They are All breakers are shipped factory assembled, complete with Cu/Al
UL listed only as complete units. To indicate required lugs, see line and load lugs.
page 6-3. All magnetic only circuit breakers and limiters are UL Component
Unless otherwise noted, all circuit breakers are UL listed in File E Recognized in Files E11592 and E66390, respectively, unless
11592. Molded case switches are UL listed in File E57546. otherwise noted.

6-2 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Molded Case Circuit Breakers Section 6
Industrial Circuit Breakers

Spectra RMS
Circuit Breakers
Determine the required breaker frame, IC rating, and load
requirements. Select frame, trip unit (rating plug), and lug,
if required, product numbers from the tables on pages 6-45
to 6-53. For Spectra breakers with microEntelliGuard Trip
Units refer to pages 6-54 through 6-61. Select field-mounted
internal accessory product numbers, if required, on pages 6-67
and 6-68. Select field-mounted external accessory product
numbers, if required, on pages 6-95 through 6-106 and pages
6-62 to 6-66 for Spectra breakers with microEntelliGuard
Trip Units. Order as separate items.
Mag-Break Motor Circuit Protectors
Determine the required frame and ampere requirements.
Select frame, trip unit (rating plug), and lug, if required,
product numbers from the table on pages 6-91 through 6-92.
Select accessories as noted above for circuit breakers. The Spectra Circuit Breakers
same accessories are used with both circuit breakers and and Molded Case Switches
motor circuit protectors. Order as separate items.
Molded Case Switches
Determine the required frame and ampere requirements. Molded Case Circuit Breaker and Switch Terminal
Select frame and lug, if required, product numbers from Configuration Code
the table on page 6-90. Rating plugs are not used. Select
Order standard Cu/Al lugs by using suffix codes presented. Order
accessories as noted above for circuit breakers. Internal
lugs separately if special lugs are required. For optional lugs, see
accessories do not require dummy trips. The same
pages 6-103 and 6-104.
accessories are used with both circuit breakers and molded
case switches. Order as separate items. Suffix
Breaker/Switch
Unless otherwise noted, all circuit breakers are UL listed in File E Type Blank WL XL X2 LL

11592. Molded case switches are UL listed in File E57546. TQD/TJD


Load Lugs Line and

Line Lugs
No Lugs
Only Load Lugs Only
Field-Installable Internal Accessories are UL listed in File E57253.
Molded Case
Distribution Cable Accessories for microEntelliGuard Trip Breakers, Thermal Load Lugs Line and

Load Lugs
No Lugs
Magnetic Only Load Lugs Only
Units are UL listed in File E57253.
Molded Case Line and Line Lugs Load Lugs
Switch Load Lugs No Lugs Only Only
Spectra RMS
No Lugs Order Lugs Separately
Accessories Breakers
Mine Duty
Order accessories from the appropriate table: Breakers No Lugs Order Lugs Separately
Thermal Magnetic Circuit Breakers, Magnetic Circuit Breakers, Mag-Break Line and

and Molded Case Switches1pages 6-39 to 6-44 and 6-94 Breakers Load Lugs

to 6-106.
Spectra RMS Breakerspages 6-66 to 6-67 and 6-94 to
6-106.
Spectra RMS Breakers with microEntelliGuard Trip Units
pages 6-62 to 6-68, and 6-94 to 6-106.
1Installation of accessories in molded case switches requires dummy trip; see page
6-44 for information. Dummy trip not required for Tri-Break or Q-Line molded
case switches.

Rev. 11/13 www.geindustrial.com BuyLog Catalog 6-3


Data subject to change
without notice
Molded Case Circuit Breakers Section 6

Features
Spectra RMS Molded Case Circuit Breakers
SE150, SF250, SG600, and SK1200 circuit breaker frames have a
digital, solid-state, rms sensing trip system with field installable,
front-mounted rating plugs to establish or change the breaker
ampere rating. Adjustable instantaneous with tracking short-time
is standard on all frames including SE150. The trip system uses
digital sampling to determine the rms value of sinusoidal and
nonsinusoidal currents.

microEntelliGuard Trip Units


Spectra SG600 and SK1200 breakers are now available with
microEntelliGuard trip units - the newest and most advanced trip
unit available in the Spectra line of molded case circuit breakers.
Based on the EntelliGuard TU trip unit platform, the
microEntelliGuard trip unit has the same HMI interface and
incorporates the advanced features and protective functions for
improved system protection, coordination, selectivity, perform-
ance, and diagnostic capabilities. New features offered with the
microEntelliGuard trip unit include enhanced time-current curve
shaping capability, ground fault alarm, direct Modbus communi-
cations, reduced energy let-through setting, zone selective inter-
lock, neutral protection, waveform capture, and programmable Spectra SG600 and SK1200 Breakers
output contacts. The microEntelliGuard trip unit utilizes the same with microEntelliGuard Trip Units
power management accessories offered for the Spectra
MicroVersaTrip with the addition of a new advanced junction
box and interconnect cables. The breakers have the same foot-
print and interrupt ratings as their SG/SK counterparts and are
backwards compatible with existing equipment and installations.
The microEntelliGuard trip unit uses the same universal rating
plugs and test kit offered for the EntelliGuard TU trip unit.
Spectra molded cases circuit breakers with microEntelliGuard
trip units can be part of an ArcWatch solution.
GEs ArcWatch system solution involves a combination of
intelligent trip units and current limiting molded case circuit
breakers to create a no compromise solution; safety and
reliability together. Advances in zone selective interlocking (ZSI)
and waveform recognition algorithms allow entire systems
to be designed so that full selectivity and 100% instantaneous
protection at calculated arcing current is possible. For most
industrial systems, the GE ArcWatch solution will result
in incident energy under 8 cal/cm2 at 18.
Enabling ArcWatch means the proper coordination analysis
techniques have been used to determine the necessary
circuit breaker protection features and settings that allow full
coordination in the given system. The circuit breaker must be
set to match the results of the completed study.
For more information, check out www.geindustrial.com/ArcWatch
(Publication DET-760) or contact your local sales representative.

6-4 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Molded Case Circuit Breakers Section 6

Record Plus Molded Case Circuit Breakers


Record Plus represents the very latest in molded case circuit
breaker design. Utilizing design features such as double-break
rotary contact structures and advanced ablative materials to
enhance interruption, Record Plus is capable of interrupting
ratings up to 200kA. High kAIC ratings, selective coordination,
reduced arc flash energy, and current limitation embody the
core design principles of Record Plus.
FC 100 and FB 100 circuit breakers are supplied with factory
installed non-user interchangeable thermal-magnetic trip units
and can be supplied with or without lugs. FB breakers are avail-
able in 1-, 2- and 3-pole versions. FC is available in 2- and 3-pole
versions, both in a 3-pole footprint.
FE 250 circuit breakers are supplied with factory installed, non-user
interchangeable PremEon S electronic trip units that feature the
use of front accessible, user adjustable dials to establish or change
the breakers amp rating.Adjustable instantaneous with tracking
short-time is standard.Ground fault protection is optional. FE is
available in 2- or 3-pole versions, both in a 3-pole footprint.
FG 600 circuit breakers are supplied with factory installed, non-
user interchangeable electronic trip units.Customers can select
from the PremEon S or SMR2 electronic trip units.PremEon S Record Plus Molded Case Circuit Breakers
features the use of front accessible, user adjustable dials to
establish or change the breakers amp rating.Adjustable
instantaneous with tracking short-time is standard.Ground fault
protection is optional.
SMR2 uses rating plugs to establish or change the breakers amp Other MCCB Features
rating. Rating plugs are user specified and ordered under separate UL489/cUL489 Listed
product number. SMR2 allows individual adjustment of Long-Time Broad product line to meet virtually any application need.
delay, Short-Time pickup and Delay, and Ground Fault Pickup and Reduced downtime. A tripped breaker is easily spotted and can
Delay (if so equipped). Zone Selective Interlocking (ZSI), Ground be immediately reset after the fault has been corrected.
Fault Alarm, and Modbus Communications are also available via Eliminates single phasing. A common trip bar disconnects all
the SMR2s interface. FG is available in 2- and 3-pole versions, poles simultaneously on both overloads and short circuits.
both in a 3-pole footprint. Offers application flexibility through the use of a wide variety of
All frames use common internal accessories (auxiliary switches, UV accessory devices and special attachments.
releases, shunt trips, and bell alarms) UL listed for field installation. Repetitive operationno fuses to replace.
Breakers can be repetitively tested. Fuses must be destroyed to
UL listed maximum short circuit ratings at 480VAC are 150kA for
confirm calibration accuracy.
the 100A frames, 100kA for the 250A frame and 200kA for the
600A frames. For more information on these products, order publications listed
in Sections 27 and 28.
Unless noted otherwise, all circuit breakers and accessories are
listed in UL file number E11592.

Rev. 11/13 www.geindustrial.com BuyLog Catalog 6-5


Data subject to change
without notice
Molded Case Circuit Breakers Section 6

Quick Reference Guide

Ratings do not apply to molded case switches.


The interruption ratings and voltages shown in the table are
maximum ratings. A circuit breaker of the type given in the left-
hand column may be applied at the given circuit voltage in any
electrical distribution system where the available fault current at
the load terminals of the breaker does not exceed the value in the
table. That circuit breaker type may also be applied at intermedi-
ate values of circuit voltage provided the available fault current at
the load terminals of the breaker does not exceed the value in the
THQL 32015
table for the higher value of voltage.

Q-Line (UL file E-11592; Fixed Thermal Magnetic Trip Unit)


UL Listed Interrupting Ratings
rms Symmetrical kA
Maximum
Circuit Voltage Rating Vac Vdc Dimensions (in.)
Breaker Ampere No. Std.
Type Rating Poles ac dc 120 120/240 240 277 480 600 125 250 H W D A B C E Pack

15-50 1 120/240 10 3/4 10


TQ 3 2 3/8
15-60 2 120/240 10 1 1/2 5
1 1/2 100
THQP1 15-50 120/240 10 3 9/32 2 3/8
2 1 50
1 1 50
TQL/TQB/ 120/240 52
10 2 3 9/32 2 2 3/8 25
TQC 5 2
3 240 3 15
15-70 1 1 50
THQL1 120/240 10
THQB1 15-125 2
3 9/32 2 2 3/8 25
THQC1 10
15-100 3 240 3 15
15-70 1 1 50
THHQB1 120/240 22
2 3 9/32 2 2 3/8 25
THHQC1 15-100 22
3 240 3 15
15-70 1 1 50
120/240 22
THHQL1 15-125 2 3 9/32 2 2 3/8 25
22
15-100 3 240 3 15
1 1 50
TXQL1 120/240 65
TXQB1 15-30 2 3 9/32 2 2 3/8 25
TXQC1 65
3 240 3 15
100-225 2 240 10 10 2 3/4 1
TQD1 6 9/16 2 5/8 2 7/16 2 7/16 27/32
100-225 3 240 10 4 1/8 11/16 1
100-225 2 240 22 22 2 3/4 1
THQD1 6 9/16 2 5/8 2 7/16 2 7/16 27/32
100-225 3 240 22 4 1/8 11/16 1
2 240 22 22 10 1
TJD 250-400 10 1/8 8 1/4 3 13/16 3 15/16 3 13/16 1 3/8 1 3/16
3 240 22 1
CB3 Ground Fault, Equipment Ground Fault and Arc Fault (UL File E-51075; Fixed Thermal Magnetic Trip Unit)
THQL 1 120 10 1 10
THQB 15-30 3 9/32 2 3/8
THQC
...GF, GFEP 2 120/240 10 2 10

THHQL
THHQB 15-30 1 120 22 3 9/32 1 2 3/8 10
...GF
THQL
THQB 15-20 1 120/240 10 3 9/32 1 2 3/8 10
THQC
...AF
THHQL
THHQB 15-20 1 120/240 22 3 9/32 1 2 3/8 10
...AF
1 UL listed as HACR (heating, air conditioning and refrigeration).
2
Not UL listed.

6-6 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Molded Case Circuit Breakers Section 6
Industrial Circuit Breakers
Quick Reference Guide
10-1200A Circuit Breakers
Thermal Magnetic Trip

Ratings do not apply to molded case switches.


Maximum interruption ratings and voltages shown. A circuit breaker of
the type given in the left-hand column may be applied at the given cir-
cuit voltage in any electrical distribution system where the available fault
current at the load terminals of the breaker does not exceed the value in
the table. TEYD, TEYH, TEYL
That circuit breaker type may also be applied at intermediate values of
circuit voltage provided the available fault current at the load terminals
of the breaker does not exceed the value in the table for the higher
value of voltage.
TEY and TEYF (UL/cUL File E-11592; CSA LR 57114), TEYD/H/L (UL/cUL File E-11592)

UL Listed Interrupting RatingkA


Maximum
Vac Vdc
Voltage Rating Dimensions (in) Approx. Ship
Circuit
Breaker Ampere No. 120/ Wt./Std.
ac dc 120 240 240 277 480/277 480 600 125 250 500 H W D A B C E
Type Rating Poles Pack
1 277 125 65 14 14 10 1
TEY2,3 15-100 2 250 10 5 1/4 2 3 1/16
480/277 65 14 14
3 3
15-60 1 277 125 65 18 18 10 1
TEYF2,3 2 250 10 5 1/4 2 3 1/16
15-125 480/277 65 18 18
3 3
15-70 1 277 65 65 25 1 1 lb
TEYD 2 5 1/4 2 3 1/16 2 lb
15-125 480/277 65 65 25
3 3 2.7 lb
15-70 1 277 65 65 35 1 1 lb
TEYH 2 5 1/4 2 3 1/16 2 lb
15-125 480/277 65 65 35
3 3 2.7 lb
15-70 1 277 125 100 100 65 15 1 1 lb
TEYL 2 42 20 5 1/4 2 3 1/16 2 lb
15-125 480/277 250 100 100 65
3 42 35 3 2.7 lb
E150 (UL/cUL File E-11592; CSA LR 57114)

1 120 125 10 5 1 3/8 26 lb/24



TEB2,3 10-1004 2 250 10 5 6 5/16 2 3/4 3 3/8 2 41/64 2 15/64 23/32 24 lb/12
240
3 10 4 1/8 11/16 28 lb/8

10-1004 1 277, 3475 125 14 10 10 1 3/8 26 lb/24



TED2,3 2 480 250 10 6 5/16 2 3/4 3 3/8 2 41/64 2 15/64 23/32 24 lb/12
10-1504 18 18
37 480, 600 500 14 10 101 4 1/8 11/16 28 lb/8
15-30 1 277, 3475 125 65 106 1 3/8 26 lb/24
15-100 2 480 250 65 106 24 lb/12
THED2,3 6 5/16 3 3/8 2 41/64 2 15/64 23/32
20-100 65 25 4 1/8 11/16
37 600 500 18 10 101 28 lb/8
110-150 42

J600 (UL File E-11592; TJJ, Fixed Thermal Magnetic Trip Unit; TJK, THJK: Interchangeable Thermal Mag. Trip Unit; CSA LR 40350)

TJJ, 2 250 20 16 lb/1


200-400 600 42 30 22 10 1/8 8 1/4 3 13/16 3 15/16 3 13/16 1 3/8 1 3/16
TJK4 3 500 20 201 17 1/2 lb/1
2 250 20 18 lb/1
TJK6 250-600 600 42 30 22 10 1/8 8 1/4 3 13/16 3 15/16 3 13/16 1 3/8 1 3/16
3 500 20 201 20 lb/1
2 250 40 16 lb/1
THJK4 200-400 600 65 35 25 10 1/8 8 1/4 3 13/16 3 15/16 3 13/16 1 3/8 1 3/16
3 500 40 201 17 1/2 lb/1
2 250 40 18 lb/1
THJK6 250-600 600 65 35 25 10 1/8 8 1/4 3 13/16 3 15/16 3 13/16 1 3/8 1 3/16
3 500 40 201 20 lb/1
Mag-Break (UL Files E-11592, E-66390; Magnetic Trip Unit)8

16 lb/1
TJC 400-600 3 600 42 30 22 10 1/8 8 1/4 3 13/16 3 13/16 3 13/16 1 3/8 1 3/16
17 1/2 lb/1

1UL listed with poles in series for 500 Vdc ungrounded battery applications. 5UL/CSA listed for 10kA @ 347 Vac (TED) and 18kA @ 347V (THED).
2UL listed as HACR (heating, air conditioning, and refrigeration). Rated 10kA @ 480V but not UL listed.
315-50A UL listed as HID (high intensity discharge). 6UL listed 10kA, GE tested to 20kA.
410 amp not UL listed, rated 5kA @ 120V, 240V and 480V 7TED, 3P, 600V, 15A breaker is obsolete. (TED136015WL & THED136015WL)
8Per UL 489, interrupting capacities are not shown on product label.

Rev. 11/13 www.geindustrial.com BuyLog Catalog 6-7


Data subject to change
without notice
Molded Case Circuit Breakers Section 6
Industrial Circuit Breakers
Quick Reference Guide
15-1200A Circuit Breakers
Electronic Trip
Ratings do not apply to molded case switches. The interruption ratings and voltages shown in
the table are maximum ratings. A circuit breaker of the type given in the left-hand column may
be applied at the given circuit voltage in any electrical distribution system where the available
fault current at the load terminals of the breaker does not exceed the value in the table. That
circuit breaker type may also be applied at intermediate values of circuit voltage provided the
available fault current at the load terminals of the breaker does not exceed the value in the table
for the higher value of voltage. SE 150

Spectra RMS Circuit Breakers UL/CSA Ratings


Solid-State with Interchangeable Trip Unit (Rating Plug)

Circuit UL Listed Interrupting RatingkA Dimensions Inches (mm) Approx.


Breaker Ampere No. Maximum Ship Wt./
Type Rating Poles Vac 240 Vac 480 Vac 600 Vac H W D A B C E Std. Pack
SE150 Current Limiting (UL File No. E-11592; CSA LR 40350)1
2 480
SED2,3 18 18
3 600 14
15-150
2 480
SEH2 65 25
3 600 18 6.31 4.12 3.38 2.41 2.47 .69 .72
5.65 lb/1
2 480 (160) (105) (86) (61) (63) (18) (18)
SEL 100 65
3 600 25
15-150
2 480
SEP 200 100
3 600 25

SF-250 Current Limiting (UL File No. E-11592; CSA LR 40350)1


2 480
SFH2 70-250 65 35
3 600 22
2 480 10.12 4.12 3.81 3.87 3.87 .69 1.19
SFL 100 65 9.15 lb/1
3 600 25 (257) (105) (97) (98) (98) (18) (30)
70-250
2 480
SFP 200 100
3 600 25
SG600 Current Limiting (UL File No. E-11592; CSA LR 40350)1,4
SGH12,5 6-150 3 600 65 35 25
2
SGD2 240 65
3
125-400
2
SGH42 600 65 35 25
3
2
SGH62 250-600 600 65 35 25
3
SGL15 3 600 100 65 65
60-150 10.096 5.50 3.81 4.45 3.30 .91 1.186
SGP15 3 600 200 100 65 (256) (140) (97) (113) (84) (23) (30)
15.85 lb/1
2
SGL4 600 100 65 65
3
125-400
2
SGP4 600 200 100 65
3
2
SGL6 600 100 65 65
3
250-600
2
SGP6 600 200 100 65
3
SK1200 (UL File No. E-11592; CSA LR 40350)1,4
2
SKH8 600 65 50 25
3
2
SKL8 300-800 600 100 65 42
3
2
SKP8 600 200 100 65
3
2
SKH12 600 65 50 25
3 15.507 8.25 5.50 8.56 5.69 1.38 .627
47.6 lb/1
2 (394) (210) (140) (217) (145) (35) (16)
SKL12 600-1200 600 100 65 42
3
2
SKP12 600 200 100 65
3
SKS8 3 200 100
800-1200 480
SKT8 3 100 65
SKS12 3 200 100
800-1200 480
SKT12 3 100 65
1UL listed as HACR (heating, air conditioning and refrigeration). 5microEntelliGuard, MicroVersaTrip Plus and MicroVersaTrip PM Trip Units only.
1
2Not current-limiting circuit breaker. 6Add 1.76 inches (45 mm) to each end with lugs and lug cover installed.
3UL listed as HID (high intensity discharge). 7Add 4.00 inches (101 mm) to upper end for SKP (100 kAIC-480V) lug cover.
4Includes microEntelliGuard Trip Units.

6-8 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Molded Case Circuit Breakers Section 6
Industrial Circuit Breakers
Quick Reference Guide
15-1200A Circuit Breakers
Electronic Trip
Ratings do not apply to molded case switches

IEC/JIS Ratings
Solid-State with Interchangeable Trip Unit (Rating Plug)
Japanese Industry Standard
IEC 947-2 Interruption Capacity kA Interruption Capacity kA
Circuit 220-240 Vac 380-415 Vac 500 Vac 690 Vac Vac
Breaker Ampere No.
Type Rating Poles Icu I cs I cu I cs I cu I cs I cu I cs 220-240 380-415 500 690
SE150 Current Limiting, 15-32A
2
SED 18 9 10 5 18 10
3 4 4 4
15-32
2
SEH 65 33 15 10 65 15
3 6 6 6
2
SEL 100 50 20 15 100 20
3 8 8 3 3 8 3
15-32
2
SEP
3
200 100 20 20
10 10 5 5
200 20
10 5
SE
SE150 Current Limiting, 40-160A
2
SED 18 9 14 7 18 14
3 14 7 14
40-160
2
SEH 65 33 35 17 65 25
3 25 12 18
2
SEL 100 50 65 33 100 65
3 40 20 5 5 25 5
40-160
2
SEP 200 100 100 50 200 100
3 50 25 10 5 65 10
SF250 Current Limiting
2
SFH 70-250 65 33 35 17 65 25
3 25 12 18
2
SFL 100 50 65 33 100 65
3 40 20 14 7 25 14
70-250
2 SF
SFP 200 100 100 50 200 100
3 65 33 18 9 65 18
SG600 Current Limiting
SGH11 65 33 25 13 18 9 65 25 18
SGL11 60-150 3 100 50 65 33 35 18 14 7 100 65 35 22
SGP11 200 100 100 50 50 25 18 9 200 100 65 35
2
SGH4 65 33 25 13 65 25
3 18 9 18
2
SGL4 125-400 100 50 65 33 100 65
3 35 18 14 7 35 22
2
SGP4 200 100 100 50 200 100
3 50 25 18 9 65 35
2
SGH6 65 33 25 13 65 25
3 18 9 18
2
SGL6 250-600 100 50 65 33 100 65
3 35 18 14 7 35 22
2
SGP6 200 100 100 50 200 100
3 50 25 18 9 65 35
SK1200 SG
2
SKH8 65 16 50 13 25 13 65 50 25
3
2
SKL8 300-800 100 25 65 16 42 21 14 14 100 65 42 14
3
2
SKP8 140 35 85 25 50 25 18 18 140 85 50 18
3
2
SKH12 65 16 50 13 25 13 65 50 25
3
2
SKL12 600-1250 100 25 65 21 42 16 14 14 100 65 42 14
3
2
SKP12 140 35 70 25 50 25 18 18 140 85 50 18
3
1 microEntelliGuard, MicroVersaTrip Plus, and MicroVersaTrip PM Trip Units only.

SK

Rev. 11/13 www.geindustrial.com BuyLog Catalog 6-9


Data subject to change
without notice
Molded Case Circuit Breakers Section 6
Industrial Circuit Breakers
Quick Reference Guide
15-600A Record Plus Circuit Breakers

The interruption ratings and voltages shown in the table are maximum ratings. A circuit breaker
of the type given in the left-hand column may be applied at the given circuit voltage in any
electrical distribution system where the available fault current at the load terminals of the
breaker does not exceed the value in the table. That circuit breaker type may also be applied at
intermediate values of circuit voltage provided the available fault current at the load terminals of
the breaker does not exceed the value in the table for the higher value of voltage.

FG 600

Ratings
FC 100 Amp Frame; Current Limiting (UL/cUL File No. E-11592)
Maximum UL Listed Interrupting Ratings - IEC Listed Interrupting Ratings, Approx.
Circuit Voltage rms Symmetrical Amperes (in Thousands) Icu, Amperes (in Thousands) Ship
Breaker Ampere No. Rating Vac Vdc Vac Vdc Dimensions in. (mm.) Wt./Std.
Type Rating Poles AC DC 240 480 600/347 250 (2p) 500 (3p) 220-240 400-415 500 250 (2p) 500 (3p) H W D Pack
FCS 15-100 2, 3 600 500 42 25 18 22 30 36 22 14 22 30 6.4 (162.6) 3.0 (76.2) 3.2 (81.3) 2.5 lb/1
FCV 15-100 2, 3 600 500 65 35 22 25 35 50 30 18 25 35 6.4 (162.6) 3.0 (76.2) 3.2 (81.3) 2.5 lb/1
FCN 15-100 2, 3 600 500 150 65 25 30 42 85 50 22 30 42 6.4 (162.6) 3.0 (76.2) 3.2 (81.3) 2.5 lb/1
FCH 15-100 2, 3 600 500 200 100 35 42 65 100 80 36 42 65 6.4 (162.6) 3.0 (76.2) 3.2 (81.3) 2.5 lb/1
FCL 15-100 2, 3 600 500 200 150 42 65 80 200 150 50 65 80 6.4 (162.6) 3.0 (76.2) 3.2 (81.3) 2.5 lb/1
FB 100 Amp Frame; Current Limiting (UL/cUL File No. E-11592)
Maximum UL Listed Interrupting Ratings - Approx.
Circuit Voltage rms Symmetrical Amperes (in Thousands) Ship
Breaker Ampere No. Rating Vac Dimensions in. (mm.) Wt./Std.
Type Rating Poles AC DC 240 277 347 480 600/347 H W D Pack
1 600/347 35 35 22 6.45 (163.8) 1.36 (34.5) 3.28 (83.3) 1.1 lb/1
FBV 15-100 2 600/347 65 35 22 6.45 (163.8) 2.74 (69.6) 3.28 (83.3) 2.6 lb/1
3 600/347 65 35 22 6.45 (163.8) 4.11 (104.4) 3.28 (83.3) 3.3 lb/1
1 600/347 65 65 25 6.45 (163.8) 1.36 (34.5) 3.28 (83.3) 1.1 lb/1
FBN 15-100 2 600/347 150 65 25 6.45 (163.8) 2.74 (69.6) 3.28 (83.3) 2.6 lb/1
3 600/347 150 65 25 6.45 (163.8) 4.11 (104.4) 3.28 (83.3) 3.3 lb/1
1 600/347 100 100 35 6.45 (163.8) 1.36 (34.5) 3.28 (83.3) 1.1 lb/1
FBH 15-100 2 600/347 200 100 35 6.45 (163.8) 2.74 (69.6) 3.28 (83.3) 2.6 lb/1
3 600/347 200 100 35 6.45 (163.8) 4.11 (104.4) 3.28 (83.3) 3.3 lb/1
1 600/347 100 100 42 6.45 (163.8) 1.36 (34.5) 3.28 (83.3) 1.1 lb/1
FBL 15-100 2 600/347 200 150 42 6.45 (163.8) 2.74 (69.6) 3.28 (83.3) 2.6 lb/1
3 600/347 200 150 42 6.45 (163.8) 4.11 (104.4) 3.28 (83.3) 3.3 lb/1
FE 250 Amp Frame; Current Limiting (UL/cUL File No. E-11592)
Maximum UL Listed Interrupting Ratings - Approx.
Circuit Voltage rms Symmetrical Amperes (in Thousands) Ship
Breaker Ampere No. Rating Vac Dimensions in. (mm.) Wt./Std.
Type Rating Poles AC DC 240 480 600 H W D Pack
FEN 250 2 480 - 150 65 - 6.70 (170.1) 4.11 (104.4) 3.52 (89.5) 4.5 lb/1
FEN 250 3 480 - 150 65 - 6.70 (170.1) 4.11 (104.4) 3.52 (89.5) 4.5 lb/1
FEH 250 2 480 - 200 100 - 6.70 (170.1) 4.11 (104.4) 3.52 (89.5) 4.5 lb/1
FEH 250 3 480 - 200 100 - 6.70 (170.1) 4.11 (104.4) 3.52 (89.5) 4.5 lb/1
FG 600 Amp Frame; Current Limiting (UL/cUL File No. E-11592)
Maximum UL Listed Interrupting Ratings - EN 60947-2 Interrupting Ratings, Approx.
Circuit Voltage rms Symmetrical Amperes (in Thousands) Icu, Amperes (in Thousands) Ship
Breaker Ampere No. Rating Vac Vac Dimensions in. (mm.) Wt./Std.
Type Rating Poles AC DC 240 480 600 240 400-415 690 H W D Pack
2 600 150 65 25 10.31 (262.0) 5.46 (138.7) 4.53 (115.0) 22 lb/1
FGN 250-600
3 600 150 65 25 85 50 10 10.31 (262.0) 5.46 (138.7) 4.53 (115.0) 22 lb/1
2 600 200 100 35 10.31 (262.0) 5.46 (138.7) 4.53 (115.0) 22 lb/1
FGH 250-600
3 600 200 100 35 100 80 22 10.31 (262.0) 5.46 (138.7) 4.53 (115.0) 22 lb/1
2 600 200 150 42 10.31 (262.0) 5.46 (138.7) 4.53 (115.0) 22 lb/1
FGL 250-600
3 600 200 150 42 200 150 40 10.31 (262.0) 5.46 (138.7) 4.53 (115.0) 22 lb/1
2 600 200 200 65 10.31 (262.0) 5.46 (138.7) 4.53 (115.0) 22 lb/1
FGP 250-600
3 600 200 200 65 10.31 (262.0) 5.46 (138.7) 4.53 (115.0) 22 lb/1

6-10 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Molded Case Circuit Breakers Section 6
Industrial Circuit Breakers
OBSOLETE PRODUCT
Quick Reference Guide
15-1200A Circuit Breakers
Thermal Magnetic Trip
Ratings do not apply to molded case switches.
Maximum interruption ratings and voltages shown.
A circuit breaker of the type given in the left-hand column may be applied at the given circuit
voltage in any electrical distribution system where the available fault current at the load
terminals of the breaker does not exceed the value in the table.
That circuit breaker type may also be applied at intermediate values of circuit voltage provided
the available fault current at the load terminals of the breaker does not exceed the value in the TFJ/TFK
table for the higher value of voltage.

E150 (UL File E-11592; CSA LR 57114)

UL Listed Interrupting RatingkA


Maximum
Voltage Approx.
Vac Vdc Dimensions (in)
Rating Ship
Circuit
Breaker Ampere No. 120/ Wt./Std.
ac dc 120 240 277 480 600 125 250 500 600 H W D A B C E
Type Rating Poles 240 Pack

TED2,3 15 3 600 500 18 18 14 10 101 6 5/16 4 1/8 3 3/8 2 41/64 2 15/64 11/16 23/32 28 lb/8

THED2,3 15 3 600 500 65 25 18 10 101 6 5/16 4 1/8 3 3/8 2 41/64 2 15/64 11/16 23/32 28 lb/8

F225 (UL File E-11592; TFJ, Fixed Thermal Magnetic Trip Unit; TFK, THFK: Interchangeable Thermal Mag. Trip Unit; CSA LR 40350)

70-225 2 480 250 10 10 lb/1


TFJ2 25 22 10 1/8 4 1/8 3 13/16 3 7/8 3 7/8 11/16 1 3/16
70-250 3 600 500 18 10 101 12 lb/1

2 480 250 10 10 lb/1


TFK2 70-225 25 22 10 1/8 4 1/8 3 13/16 3 7/8 3 7/8 11/16 1 3/16
3 600 500 18 10 101 12 lb/1

2 480 250 10 10 lb/1


THFK2 70-225 65 25 10 1/8 4 1/8 3 13/16 3 7/8 3 7/8 11/16 1 3/16
3 600 500 18 10 101 12 lb/1

TFL8 70-225 3 600 100 100 65 25 10 1/8 4 1/8 3 13/16 3 7/8 3 7/8 11/16 1 3/16

J600 (UL File E-11592; TJJ, Fixed Thermal Magnetic Trip Unit; TJK, THJK: Interchangeable Thermal Mag. Trip Unit; CSA LR 40350)

TJJ, 2 250 20 16 lb/1


125-175 600 42 30 22 10 1/8 8 1/4 3 13/16 3 15/16 3 13/16 1 3/8 1 3/16
TJK4 3 500 20 201 17 1/2 lb/1

2 250 20 18 lb/1
TJK6 125-175 600 42 30 22 10 1/8 8 1/4 3 13/16 3 15/16 3 13/16 1 3/8 1 3/16
3 500 20 201 20 lb/1

2 250 40 16 lb/1
THJK4 125-175 600 65 35 25 10 1/8 8 1/4 3 13/16 3 15/16 3 13/16 1 3/8 1 3/16
3 500 40 201 17 1/2 lb/1

2 250 40 18 lb/1
THJK6 125-175 600 65 35 25 10 1/8 8 1/4 3 13/16 3 15/16 3 13/16 1 3/8 1 3/16
3 500 40 201 20 lb/1

THJK4 D 125-400 3 600 40 50 25 10 1/8 8 1/4 3 13/16 3 15/16 3 13/16 1 3/8 1 3/16 17 1/2 lb/1

THJK6 D 250-400 3 600 40 50 25 10 1/8 8 1/4 3 13/16 3 15/16 3 13/16 1 3/8 1 3/16 20 lb/1

K1200 (UL File E-11592; Interchangeable Thermal Magnetic Trip Unit; CSA LR 40350)

2 250 20 33 lb/1
TKM8 300-800 600 42 30 22 15 1/2 8 1/4 5 1/2 8 9/16 5 11/16 1 3/8 5/8
3 500 20 221 39 lb/1

2 38 lb/1
TKM12 600-1200 600 42 30 22 15 1/2 8 1/4 5 1/2 8 9/16 5 11/16 1 3/8 5/8
3 41 1/2 lb/1

2 250 40 33 lb/1
THKM8 300-800 600 65 35 25 15 1/2 8 1/4 5 1/2 8 9/16 5 11/16 1 3/8 5/8
1
3 500 40 22 39 lb/1

2 38 lb/1
THKM12 600-1200 600 65 35 25 15 1/2 8 1/4 5 1/2 8 9/16 5 11/16 1 3/8 5/8
3 41 1/2 lb/1

1UL listed with poles in series for 500 Vdc ungrounded battery applications. 6480Y/277 Vac.
2UL listed as HACR (heating, air conditioning, and refrigeration). 7UL listed 10kA, GE tested to 20kA.
315-50A UL listed as HID (high intensity discharge). 8Not CSA listed
410 amp not UL listed, rated 5kA @ 120V, 240V and 480V
5UL listed/CSA Certified for 10kA @ 347 Vac (TED) and 18kA @ 347V (THED).
Also rated 10kA @ 480V but not UL listed.

Rev. 11/13 www.geindustrial.com BuyLog Catalog 6-11


Data subject to change
without notice
Molded Case Circuit Breakers Section 6
Industrial Circuit Breakers

TF and TK Cross Reference Table


Transition guide Obsoleted TF and TK Molded Case Circuit Breakers, switches and Motor Circuit Protectors to Spectra RMS equivalents.
Spectra RMS products are not DC rated. For DC applications, continue use of TJ frame Molded Case Circuit Breakers.

Molded Case Circuit Breakers

Obsoleted Frame Rating Plug Lugs


Frame Product Product Product Product
F225 AIC Rating Trip Unit Poles Voltage Number Spectra AIC Poles Voltage Number Number Number
22kA 225A noninterchangeable 2 480V TFJ224XXX SFH 35kA 2 480V SFHA24AT0250 SRPF250AXXX (2) TCAL29
TFJ 22kA 225A noninterchangeable 3 600V TFJ236XXX SFH 35kA 3 600V SFHA36AT0250 SRPF250AXXX (3) TCAL29
22kA 225A interchangable 2 480V TFK224XXX SFH 35kA 2 480V SFHA24AT0250 SRPF250AXXX (2) TCAL29
TFK 22kA 225A interchangable 3 600V TFK236XXX SFH 35kA 3 600V SFHA36AT0250 SRPF250AXXX (3) TCAL29
25kA 225A interchangable 2 480V THFK224XXX SFH 35kA 2 480V SFHA24AT0250 SRPF250AXXX (2) TCAL29
THFK
25kA 225A interchangable 3 600V THFK236XXX SFH 35kA 3 600V SFHA36AT0250 SRPF250AXXX (3) TCAL29
Molded Case Circuit Breakers
Obsoleted Frame Rating Plug Lugs
Frame Product Product Product Product
K1200 AIC Rating Trip Unit Poles Voltage Number Spectra AIC Poles Voltage Number Number Number
30kA 800A interchangeable 2 600V TKMA826XXX SKHA 50kA 2 600V SKHA26AT0800 SRPK800AXXX (2) TCAL81
TKMA 30kA 800A interchangeable 3 600V TKMA836XXX SKHA 50kA 3 600V SKHA36AT0800 SRPK800AXXX (3) TCAL81
35kA 800A interchangeable 2 600V THKMA826XXX SKHA 50kA 2 600V SKHA26AT0800 SRPK800AXXX (2) TCAL81
THKMA 35kA 800A interchangeable 3 600V THKMA836XXX SKHA 50kA 3 600V SKHA36AT0800 SRPK800AXXX (3) TCAL81
30kA 1200A interchangeable 2 600V TKMA2XXXX SKHA 50kA 2 600V SKHA26AT1200 SRPK1200AXXX (2) TCAL125
TKMA 30kA 1200A interchangeable 3 600V TKMA3XXXX SKHA 50kA 3 600V SKHA36AT1200 SRPK1200AXXX (3) TCAL125
35kA 1200A interchangeable 2 600V THKMA2XXXX SKHA 50kA 2 600V SKHA26AT1200 SRPK1200AXXX (2) TCAL125
THKMA 35kA 1200A interchangeable 3 600V THKMA3XXXX SKHA 50kA 3 600V SKHA36AT1200 SRPK1200AXXX (3) TCAL125
Molded Case Switches
Obsoleted Rating Plug Lugs
Frame Product Product Product Product
Type AIC Rating Trip Unit Poles Voltage Number Spectra AIC Poles Amps Number Number Number
TFK N/A 225A N/A 2 600V TFK226Y225 SF250 N/A 3 250A SFDA36AN0250 N/A (3) TCAL29
TFK N/A 225A N/A 3 600V TFK236Y225 SF250 N/A 3 250A SFDA36AN0250 N/A (3) TCAL29
TKM N/A 800A N/A 2 600V TKMA826Y800 SK1200 N/A 3 800A SKDA36AN0800 N/A (3) TCAL81
TKM N/A 800A N/A 3 600V TKMA836Y800 SK1201 N/A 3 800A SKDA36AN0800 N/A (3) TCAL81
TKM N/A 1000A N/A 2 600V TKMA2Y1000 SK1202 N/A 3 1000A SKDA36AN1000 N/A (3) TCAL125
TKM N/A 1000A N/A 3 600V TKMA3Y1000 SK1203 N/A 3 1000A SKDA36AN1000 N/A (3) TCAL125
TKM N/A 1200A N/A 2 600V TKMA2Y1200 SK1204 N/A 3 1200A SKDA36AN1200 N/A (3) TCAL125
TKM N/A 1200A N/A 3 600V TKMA3Y1200 SK1205 N/A 3 1200A SKDA36AN1200 N/A (3) TCAL125
Motor Circuit Protectors
Obsoleted Rating Plug Lugs
Frame Inst Trip Product Product Product Product
Type AIC Rating Amp Rating Poles Voltage Number Spectra AIC Poles Amps Number Number Number
TF 30kA 225A 600 - 1400 3 N/A TFC36225 SFLA 65kA 3 250A SFLA36AI0250 SRPF250AXXX (3) TCAL29
TF 30kA 225A 100 - 2250 3 N/A TFC36225A SFPA 100kA 3 250A SFPA36AI0250 SRPF250AXXX (3) TCAL29
TK 30kA 800A 3000 - 6000 3 N/A TKC36800L SKLA 65kA 3 800A SKLA36AI0800 SRPK800AXXX (3) TCAL81
TK 30kA 800A 5000 - 10000 3 N/A TKC36800M SKLA 65kA 3 800A SKLA36AI0800 SRPK800AXXX (3) TCAL81
TK 30kA 1200A 3000 - 6000 3 N/A TKC361200L SKLA 65kA 3 1200A SKLA36AI1200 SRPK1200AXXX (3) TCAL125
TK 30kA 1200A 5000 - 10000 3 N/A TKC361200M SKLA 65kA 3 1200A SKLA36AI1200 SRPK1200AXXX (3) TCAL125

Legend
XXX = Variable in Product Number changes per application

Spectra RMS Accessories


Description Product Number
Shunt Trip SASTX
Auxiliary Switch SAUXPABX
UV Release SAUVX
Bell Alarm SABAP1
Actuator SACTUATOR

6-12 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Molded Case Circuit Breakers Section 6
OBSOLETE PRODUCT
Quick Reference Guide
Ratings do not apply to molded case switches.
Maximum interuption ratings and voltages shown.
A circuit breaker of the type given in the left-hand column may be applied at the
given circuit voltage in any electrical distribution system where the available fault
current at the load terminals of the breaker does not exceed the value in the table.
That circuit breaker type may also be applied at intermediate values of circuit volt-
age provided the available fault current at the load terminals of the breaker does
not exceed the value in the table for the higher value of voltage.

TJL6S

Tri-Break (UL File E-42263; Integrally Fused, Thermal Magnetic Trip Unit)
UL Listed Interrupting Ratings
Maximum rms Symmetrical Amps (In Thousands) Approx.
Voltage
Circuit Ship
Rating Vac Vdc Dimensions (In.)
Breaker Ampere No. Wt./Std.
Type Rating Poles ac dc 120 120/240 240 277 480 600 125 250 H W D A B C E Pack
TB11,2 15-100 3 600 200 200 200 10 5/16 4 1/8 3 5/8 2 21/32 6 9/32 11/16 23/32 8 lb/1
31 lb/1
TB41,3 125-400 3 600 200 200 200 16 1/8 8 1/4 4 1/2 3 15/16 9 13/16 1 3/8 1 3/16
33 lb/1
53 lb/1
TB61,3 300-600 3 600 200 200 200 21 7/8 8 1/4 5 7/8 8 9/16 12 1/16 1 3/8 5/8
55 lb/1
53 lb/1
TB81,3 600-800 3 600 200 200 100 21 7/8 8 1/4 5 7/8 8 9/16 12 1/16 1 3/8 5/8
55 lb/1
Mag-Break (UL Files E-11592, E-66390; Magnetic Trip Unit)4
2 480 250 10
TEC 3-150 10 10 10 6 5/16 4 1/8 3 3/8 2 41/64 2 15/64 11/16 23/32 21 lb/6
3 600
TEML 3-150 3 600 250 100 65 25 6 5/16 4 1/8 3 7/8 2 41/64 2 15/64 11/16 23/32 3 1/2 lb/1
TEC & 1.2 lb/1
3-150 3 600 100 100 100 8 3/16 4 1/8 3 3/8 2 41/64 2 15/64 11/16 23/32 TECL Only
TECL5
10 lb/1
TFC 225 3 600 25 22 18 10 1/8 4 1/8 3 13/16 3 7/8 3 7/8 11/16 1 3/16
12 lb/1
31 lb/1
TBC4 225-400 3 600 100 100 100 16 1/8 8 1/4 4 1/2 3 15/16 9 13/16 1 3/8 1 3/16
33 lb/1
53 lb/1
TBC6 600 3 600 100 100 100 21 7/8 8 1/4 5 7/8 8 9/16 12 1/16 1 3/8 5/8
55 lb/1
38 lb/1
TKC 800-1200 3 600 42 30 22 15 1/2 8 1/4 5 1/2 8 9/16 5 11/16 1 3/8 5/8
41 1/2/1
53 lb/1
TBC8 800 3 600 100 100 100 21 7/8 8 1/4 5 7/8 8 9/16 12 1/16 1 3/8 5/8
55 lb/1
MicroVersaTrip (UL File E-11592; Solid-State Trip Units)
TJ4V6,7 42 42 30 22
THJ4V6,7 150-600 3 600 65 65 35 25 10 1/8 8 1/4 3 13/16 3 15/16 3 13/16 1 3/8 1 3/16
TJL4V6 100 100 65 30
TK4V6 800-1200 3 600 42 42 30 22 15 1/2 8 1/4 5 1/2 8 9/16 5 11/16 1 3/8 5/8
TKL4V6 800-1200 3 600 100 100 65 42 15 1/2 8 1/4 5 1/2 8 9/16 5 11/16 1 3/8 5/8

TJH1S-6S 60-600 3 600 65 65 35 25 16 1/8 8 1/4 3 13/16 3 15/16 9 13/16 1 3/8 1 3/16

TJL1S-6S 60-600 3 600 100 100 65 30 16 1/8 8 1/4 3 13/16 3 15/16 9 13/16 1 3/8 1 3/16

TKH8S, 12S 300-1200 3 600 65 65 50 25 21 7/8 8 1/4 5 1/2 8 9/16 12 11/16 1 3/8 5/8

TKL8S, 12S 300-1200 3 600 100 100 65 42 21 7/8 8 1/4 5 1/2 8 9/16 12 11/16 1 3/8 5/8
1 UL listed with internally mounted accessories at 100,000 amps IC. 5 Ratings shown for TEC in combination with TECL.
Contact GE Sales Office for availability of 200 kAIC ratings with 6 With Power+ 4 trip unit.
internal accessories. 7 Suitable for single-phase, use outer two poles.
2 CSA LR 57114.
3 CSA LR 40350.
4 Per UL 489, interrupting capacities are not shown on product label.

Rev. 11/13 www.geindustrial.com www.geindustrial.com BuyLog Catalog 6-13


Data subject to change
without notice
Molded Case Circuit Breakers Section 6
Q-Line Circuit Breakers
Plug-in Circuit Breakers
120/240V Class

TQL and THQL 120/240 Vac


# of Ampere 120/240 Vac
Poles Rating Wire Range1 Interrupting Rating Product Number
1 104 5kA TQL1110
1 152 (1) 14-8 Cu/12-8 Al 10kA THQL1115
1 202 (1) 14-8 Cu/12-8 Al 10kA THQL1120
1 25 (1) 14-8 Cu/12-8 Al 10kA THQL1125
1 30 (1) 14-8 Cu/12-8 Al 10kA THQL1130
1 35 (1) 8-3 Cu/8-3 Al 10kA THQL1135
1 40 (1) 8-3 Cu/8-3 Al 10kA THQL1140
1 45 (1) 8-3 Cu/8-3 Al 10kA THQL1145
1 50 (1) 8-3 Cu/8-3 Al 10kA THQL1150
1 60 (1) 8-3 Cu/8-3 Al 10kA THQL1160
1 70 (1) 6-1/0 Cu/4-1/0 Al 10kA THQL1170 THQL1120

THQL 120/240 Vac, with Factory Installed Shunt


# of Ampere 120/240 Vac
Poles Rating Wire Range1 Interrupting Rating Product Number
1 15 (1) 14-8 Cu/12-8 Al 10kA THQL1115ST1
1 20 (1) 14-8 Cu/12-8 Al 10kA THQL1120ST1
1 30 (1) 14-8 Cu/12-8 Al 10kA THQL1130ST1
1 35 (1) 8-3 Cu/8-3 Al 10kA THQL1135ST1
1 40 (1) 8-3 Cu/8-3 Al 10kA THQL1140ST1
1 45 (1) 8-3 Cu/8-3 Al 10kA THQL1145ST1
1 50 (1) 8-3 Cu/8-3 Al 10kA THQL1150ST1

TQL and THQL 120/240 Vac, Internal Common Trip


# of Ampere 120/240 Vac
Poles Rating Wire Range1 Interrupting Rating Product Number
2 104 5kA TQL2110
2 15 (1) 14-8 Cu/12-8 Al 10kA THQL2115
2 20 (1) 14-8 Cu/12-8 Al 10kA THQL2120
2 25 (1) 14-8 Cu/12-8 Al 10kA THQL2125
THQL1130ST1
2 30 (1) 14-8 Cu/12-8 Al 10kA THQL2130
2 35 (1) 8-3 Cu/8-3 Al 10kA THQL2135
2 40 (1) 8-3 Cu/8-3 Al 10kA THQL2140
2 45 (1) 8-3 Cu/8-3 Al 10kA THQL2145
2 50 (1) 8-3 Cu/8-3 Al 10kA THQL2150
2 60 (1) 8-3 Cu/8-3 Al 10kA THQL2160
2 70 (1) 6-1/0 Cu/4-1/0 Al 10kA THQL2170
2 80 (1) 6-1/0 Cu/4-1/0 Al 10kA THQL2180
2 90 (1) 6-1/0 Cu/4-1/0 Al 10kA THQL2190
2 100 (1) 6-1/0 Cu/4-1/0 Al 10kA THQL21100
2 110 (1) 2-2/0 Cu/2-2/0 Al 10kA THQL21110
2 125 (1) 2-2/0 Cu/2-2/0 Al 10kA THQL211253

THQP 120/240 Vac


# of Ampere 120/240 Vac
Poles Rating Wire Range1 Interrupting Rating Product Number
1 15 14-8 Cu/12-8 Al 10kA THQP115
1 20 14-8 Cu/12-8 Al 10kA THQP120 THQP130
1 25 14-8 Cu/12-8 Al 10kA THQP125
1 30 8-4 Cu/8-4 Al 10kA THQP130
1 35 8-4 Cu/8-4 Al 10kA THQP135
1 40 8-4 Cu/8-4 Al 10kA THQP140
1 45 8-4 Cu/8-4 Al 10kA THQP145
1 50 8-4 Cu/8-4 Al 10kA THQP150

THQP 120/240 Vac, Internal Common Trip


# of Ampere 120/240 Vac
Poles Rating Wire Range1 Interrupting Rating Product Number
2 15 14-8 Cu/12-8 Al 10kA THQP215
2 20 14-8 Cu/12-8 Al 10kA THQP220
2 25 14-8 Cu/12-8 Al 10kA THQP225
2 30 8-4 Cu/8-4 Al 10kA THQP230
2 35 8-4 Cu/8-4 Al 10kA THQP235
2 40 8-4 Cu/8-4 Al 10kA THQP240
2 45 8-4 Cu/8-4 Al 10kA THQP245
2 50 8-4 Cu/8-4 Al 10kA THQP250
1Solid or stranded for 14-10 AWG.
2UL listed as SWD (Switching Duty) rated. Suitable for switching 120 Vac fluorescent lighting loads.
3Recommended for use as main or submain breaker only. THQP230
4Not UL listed.

UL listed as HACR (heating, air conditioning and refrigeration).

6-14 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Molded Case Circuit Breakers Section 6
Q-Line Circuit Breakers
Plug-in Circuit Breakers
120/240V Class

TQL and THQL 240 Vac, Internal Common Trip


# of Ampere 240 Vac
Poles Rating Wire Range1 Interrupting Rating Product Number
2 10 5kA TQL22010
2 15 14-8 Cu/12-8 Al 10kA THQL22015
2 20 14-8 Cu/12-8 Al 10kA THQL22020
2 25 14-8 Cu/12-8 Al 10kA THQL22025
2 30 14-8 Cu/12-8 Al 10kA THQL22030
2 35 8-3 Cu/8-3 Al 10kA THQL22035
2 40 8-3 Cu/8-3 Al 10kA THQL22040 THQL32015
2 45 8-3 Cu/8-3 Al 10kA THQL22045
2 50 8-3 Cu/8-3 Al 10kA THQL22050
2 60 8-3 Cu/8-3 Al 10kA THQL22060
2 70 6-1/0 Cu/4-1/0 Al 10kA THQL22070
2 80 6-1/0 Cu/4-1/0 Al 10kA THQL22080
2 90 6-1/0 Cu/4-1/0 Al 10kA THQL22090
2 100 6-1/0 Cu/4-1/0 Al 10kA THQL22100
3 10 5kA TQL32010
3 15 14-8 Cu/12-8 Al 10kA THQL32015
3 20 14-8 Cu/12-8 Al 10kA THQL32020
3 25 14-8 Cu/12-8 Al 10kA THQL32025
3 30 14-8 Cu/12-8 Al 10kA THQL32030
3 35 8-3 Cu/8-3 Al 10kA THQL32035
3 40 8-3 Cu/8-3 Al 10kA THQL32040
3 45 8-3 Cu/8-3 Al 10kA THQL32045
3 50 8-3 Cu/8-3 Al 10kA THQL32050
3 60 8-3 Cu/8-3 Al 10kA THQL32060
3 70 6-1/0 Cu/4-1/0 Al 10kA THQL32070
3 80 6-1/0 Cu/4-1/0 Al 10kA THQL32080 THQL2120ST1
3 90 6-1/0 Cu/4-1/0 Al 10kA THQL32090
3 100 6-1/0 Cu/4-1/0 Al 10kA THQL32100

15-100 ampere UL Listed as HACR (heating, air conditioning and refrigeration).

THQL 120/240 Vac, Internal Common Trip with Factory Installed Shunt
# of Ampere 240 Vac
Poles Rating Wire Range1 Interrupting Rating Product Number
2 15 14-8 Cu/12-8 Al 10kA THQL2115ST1
2 20 14-8 Cu/12-8 Al 10kA THQL2120ST1
2 30 14-8 Cu/12-8 Al 10kA THQL2130ST1
2 35 8-3 Cu/8-3 Al 10kA THQL2135ST1
2 40 8-3 Cu/8-3 Al 10kA THQL2140ST1
2 45 8-3 Cu/8-3 Al 10kA THQL2145ST1
2 50 8-3 Cu/8-3 Al 10kA THQL2150ST1
2 60 8-3 Cu/8-3 Al 10kA THQL2160ST1
2 70 6-1/0 Cu/4-1/0 Al 10kA THQL2170ST1
2 80 6-1/0 Cu/4-1/0 Al 10kA THQL2180ST1
2 90 6-1/0 Cu/4-1/0 Al 10kA THQL2190ST1
2 100 6-1/0 Cu/4-1/0 Al 10kA THQL21100ST1
3 20 14-8 Cu/12-8 Al 10kA THQL32020ST1
3 30 14-8 Cu/12-8 Al 10kA THQL32030ST1 THQL32020ST1
3 40 8-3 Cu/8-3 Al 10kA THQL32040ST1
3 50 8-3 Cu/8-3 Al 10kA THQL32050ST1
3 60 8-3 Cu/8-3 Al 10kA THQL32060ST1
3 70 6-1/0 Cu/4-1/0 Al 10kA THQL32070ST1
3 80 6-1/0 Cu/4-1/0 Al 10kA THQL32080ST1
3 90 6-1/0 Cu/4-1/0 Al 10kA THQL32090ST1
3 100 6-1/0 Cu/4-1/0 Al 10kA THQL32100ST1

THQL and THHQL Vac Arc Fault


# of Ampere 120/240 Vac
Poles Rating Wire Range1 Interrupting Rating Product Number
1 15 14-10 Cu/14-10 Al 10kA THQL1115AF22
1 20 14-10 Cu/14-10 Al 10kA THQL1120AF22
1 15 14-10 Cu/14-10 Al 22kA THHQL1115AF22
1 20 14-10 Cu/14-10 Al 22kA THHQL1120AF22

Dual Function GFCI/AFCI Ground Fault & Combination Arc Fault Circuit Breaker
(Available December 2014)
# of Ampere 120 Vac
Poles Rating Wire Range1 Interrupting Rating Product Number
1 15 14-8 Cu/12-8 Al 10kA THQL1115DF
1 20 14-8 Cu/12-8 Al 10kA THQL1120DF THQL1115AF2
1 15 14-8 Cu/12-8 Al 22kA THHQL1115DF
1 20 14-8 Cu/12-8 Al 22kA THHQL1120DF
1Solid or stranded for 14-10 AWG.
2Combination AFCI compliant with NEC 2008 and later.

Rev. 11/13 www.geindustrial.com BuyLog Catalog 6-15


Data subject to change
without notice
Molded Case Circuit Breakers Section 6
Q-Line Circuit Breakers
Plug-in Circuit Breakers
240V Class

THQL and THHQL 120 Vac, Equipment Protection Ground Fault Circuit
Breakers Internal Common Trip
# of Ampere 120 Vac
Poles Rating Wire Range1 Interrupting Rating Product Number
1 15 14-8 Cu/12-8 Al 10kA THQL1115GFEP
1 20 14-8 Cu/12-8 Al 10kA THQL1120GFEP
1 30 14-8 Cu/12-8 Al 10kA THQL1130GFEP

THQL and THHQL 120/240 Vac or 208Y/120 Vac, Equipment Protection THQL2120HID
Ground Fault Circuit Breakers
# of Ampere 120/240 Vac or 208Y/120
Poles Rating Wire Range1 Interrupting Rating Product Number
2 15 14-8 Cu/12-8 Al 10kA THQL2115GFEP
2 20 14-8 Cu/12-8 Al 10kA THQL2120GFEP
2 30 14-8 Cu/12-8 Al 10kA THQL2130GFEP

THQL and THHQL 120/240 Vac, High Intensity Discharge Lighting Loads
# of Ampere 120/240 Vac
Poles Rating Wire Range1 Interrupting Rating Product Number
1 15 14-8 Cu/12-8 Al 10kA THQL1115HID2
1 20 14-8 Cu/12-8 Al 10kA THQL1120HID2
1 25 14-8 Cu/12-8 Al 10kA THQL1125HID
1 30 14-8 Cu/12-8 Al 10kA THQL1130HID
1 15 14-8 Cu/12-8 Al 22kA THHQL1115HID2
1 20 14-8 Cu/12-8 Al 22kA THHQL1120HID2
1 25 14-8 Cu/12-8 Al 22kA THHQL1125HID
1 30 14-8 Cu/12-8 Al 22kA THHQL1130HID

UL listed as HID.

THQL and THHQL 120/240 Vac, Internal Common Trip For High Intensity
Discharge Lighting Loads
# of Ampere 120/240 Vac
Poles Rating Wire Range1 Interrupting Rating Product Number
2 15 14-8 Cu/12-8 Al 10kA THQL2115HID
2 20 14-8 Cu/12-8 Al 10kA THQL2120HID
2 25 14-8 Cu/12-8 Al 10kA THQL2125HID
2 30 14-8 Cu/12-8 Al 10kA THQL2130HID
2 15 14-8 Cu/12-8 Al 22kA THHQL2115HID
2 20 14-8 Cu/12-8 Al 22kA THHQL2120HID
2 25 14-8 Cu/12-8 Al 22kA THHQL2125HID
2 30 14-8 Cu/12-8 Al 22kA THHQL2130HID

UL listed as HID.
1Solid or stranded for 14-10 AWG.
2UL listed as SWD (switching duty). Suitable for 120 Vac fluorescent lighting loads.

6-16 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Molded Case Circuit Breakers Section 6
Q-Line Circuit Breakers
Plug-in Circuit Breakers
240V Class

THQL 120/240 Vac, High In-Rush Loads


# of Ampere 120/240 Vac
Poles Rating Wire Range1 Interrupting Rating Product Number
1 15 14-8 Cu/12-8 Al 10kA THQL1115HM
1 20 14-8 Cu/12-8 Al 10kA THQL1120HM
1 25 14-8 Cu/12-8 Al 10kA THQL1125HM
1 30 14-8 Cu/12-8 Al 10kA THQL1130HM
1 40 8-3 Cu/8-3 Al 10kA THQL1140HM
1 50 8-3 Cu/8-3 Al 10kA THQL1150HM

THQL1120HM
THQL 120 Vac, For Factory Installed Shunt Trip2,3 Internal Common Trip
# of Ampere 120 Vac
Poles Rating Wire Range1 Interrupting Rating Product Number
3 20 14-8 Cu/12-8 Al 10kA THQL32020ST1

THQL 120/240 Vac, Thermal Magnetic Pole plus Nonautomatic Pole


For Switching Neutral
# of Ampere 120/240 Vac
Poles Rating Wire Range1 Interrupting Rating Product Number
2 15 14-8 Cu/12-8 Al 10kA THQL21WY15
2 20 14-8 Cu/12-8 Al 10kA THQL21WY20
THLK2125
2 25 14-8 Cu/12-8 Al 10kA THQL21WY25
2 30 14-8 Cu/12-8 Al 10kA THQL21WY30
3 15 14-8 Cu/12-8 Al 10kA THQL31WY15
3 20 14-8 Cu/12-8 Al 10kA THQL31WY20
3 25 14-8 Cu/12-8 Al 10kA THQL31WY25
3 30 14-8 Cu/12-8 Al 10kA THQL31WY30
1Solid or stranded for 14-10 AWG.
2For additional shunt trip offerings see page 6-41.
3UL listed as HACR (heating, air conditioning and refrigeration).

Rev. 11/13 www.geindustrial.com BuyLog Catalog 6-17


Data subject to change
without notice
Molded Case Circuit Breakers Section 6
Q-Line Circuit Breakers
Plug-in Circuit Breakers
240V Class

THHQL 120 Vac


# of Ampere 120 Vac
Poles Rating Wire Range1 Interrupting Rating Product Number
1 15 14-8 Cu/12-8 Al 22kA THHQL11152
1 20 14-8 Cu/12-8 Al 22kA THHQL11202
1 25 14-8 Cu/12-8 Al 22kA THHQL1125
1 30 8-3 Cu/8-3 Al 22kA THHQL1130
1 35 8-3 Cu/8-3 Al 22kA THHQL1135
1 40 8-3 Cu/8-3 Al 22kA THHQL1140
1 45 8-3 Cu/8-3 Al 22kA THHQL1145 THHQL1120
1 50 8-3 Cu/8-3 Al 22kA THHQL1150
1 60 8-3 Cu/8-3 Al 22kA THHQL1160
1 70 6-1/0 Cu/4-1/0 Al 22kA THHQL1170

THHQL 120/240 Vac, Internal Common Trip


# of Ampere 120/240 Vac
Poles Rating Wire Range1 Interrupting Rating Product Number
2 15 14-8 Cu/12-8 Al 22kA THHQL2115
2 20 14-8 Cu/12-8 Al 22kA THHQL2120
2 25 14-8 Cu/12-8 Al 22kA THHQL2125
2 30 8-3 Cu/8-3 Al 22kA THHQL2130
2 35 8-3 Cu/8-3 Al 22kA THHQL2135
2 40 8-3 Cu/8-3 Al 22kA THHQL2140
2 45 8-3 Cu/8-3 Al 22kA THHQL2145
2 50 8-3 Cu/8-3 Al 22kA THHQL2150 THHQL32015
2 60 8-3 Cu/8-3 Al 22kA THHQL2160
2 70 6-1/0 Cu/4-1/0 Al 22kA THHQL2170
2 80 6-1/0 Cu/4-1/0 Al 22kA THHQL2180
2 90 6-1/0 Cu/4-1/0 Al 22kA THHQL2190
2 100 6-1/0 Cu/4-1/0 Al 22kA THHQL21100
2 110 2-2/0 Cu/2-2/0 Al 22kA THHQL21110
2 125 2-2/0 Cu/2-2/0 Al 22kA THHQL21125

THHQL 240 Vac, Internal Common Trip


# of Ampere 240 Vac
Poles Rating Wire Range1 Interrupting Rating Product Number
2 15 14-8 Cu/12-8 Al 22kA THHQL22015
2 20 14-8 Cu/12-8 Al 22kA THHQL22020
2 25 14-8 Cu/12-8 Al 22kA THHQL22025
2 30 8-3 Cu/8-3 Al 22kA THHQL22030
2 35 8-3 Cu/8-3 Al 22kA THHQL22035
2 40 8-3 Cu/8-3 Al 22kA THHQL22040
2 45 8-3 Cu/8-3 Al 22kA THHQL22045
2 50 8-3 Cu/8-3 Al 22kA THHQL22050
2 60 8-3 Cu/8-3 Al 22kA THHQL22060
2 70 6-1/0 Cu/4-1/0 Al 22kA THHQL22070
2 80 6-1/0 Cu/4-1/0 Al 22kA THHQL22080
2 90 6-1/0 Cu/4-1/0 Al 22kA THHQL22090
2 100 6-1/0 Cu/4-1/0 Al 22kA THHQL22100
3 15 14-8 Cu/12-8 Al 22kA THHQL32015
3 20 14-8 Cu/12-8 Al 22kA THHQL32020
3 25 14-8 Cu/12-8 Al 22kA THHQL32025
3 30 8-3 Cu/8-3 Al 22kA THHQL32030
3 35 8-3 Cu/8-3 Al 22kA THHQL32035
3 40 8-3 Cu/8-3 Al 22kA THHQL32040
3 45 8-3 Cu/8-3 Al 22kA THHQL32045
3 50 8-3 Cu/8-3 Al 22kA THHQL32050
3 60 8-3 Cu/8-3 Al 22kA THHQL32060
3 70 6-1/0 Cu/4-1/0 Al 22kA THHQL32070
3 80 6-1/0 Cu/4-1/0 Al 22kA THHQL32080
3 90 6-1/0 Cu/4-1/0 Al 22kA THHQL32090
3 100 6-1/0 Cu/4-1/0 Al 22kA THHQL32100
1Solid or stranded for 14-10 AWG.
2UL listed as SWD (switching duty) rated. Suitable for switching 120 Vac fluorescent lighting loads.
UL listed HACR (heating, air conditioning and refrigeration).

6-18 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Molded Case Circuit Breakers Section 6
Q-Line Circuit Breakers
Plug-in Circuit Breakers
240V Class

TXQL 120/240 Vac


# of Ampere 120/240 Vac
Poles Rating Wire Range1 Interrupting Rating Product Number
1 15 14-8 Cu/12-8 Al 65kA TXQL11152
1 20 14-8 Cu/12-8 Al 65kA TXQL11202
1 25 14-8 Cu/12-8 Al 65kA TXQL1125
1 30 14-8 Cu/12-8 Al 65kA TXQL1130

TXQL 120/240 Vac, Internal Common Trip


# of Ampere 120/240 Vac
Poles Rating Wire Range1 Interrupting Rating Product Number
2 15 14-8 Cu/12-8 Al 65kA TXQL2115
2 20 14-8 Cu/12-8 Al 65kA TXQL2120
2 25 14-8 Cu/12-8 Al 65kA TXQL2125
2 30 14-8 Cu/12-8 Al 65kA TXQL2130
3 15 14-8 Cu/12-8 Al 65kA TXQL32015
3 20 14-8 Cu/12-8 Al 65kA TXQL32020
3 25 14-8 Cu/12-8 Al 65kA TXQL32025
3 30 14-8 Cu/12-8 Al 65kA TXQL32030
1Solid or stranded for 14-10 AWG.
2UL listed as SWD (switching duty) rated. Suitable for switching 120 Vac fluorescent lighting loads.
3Limited availability: Obsolete when inventory depleted.
UL listed HACR (heating, air conditioning and refrigeration).

Rev. 11/13 www.geindustrial.com BuyLog Catalog 6-19


Data subject to change
without notice
Molded Case Circuit Breakers Section 6
Q-Line Circuit Breakers
Bolt-on Circuit Breakers
240V Class

TQB, THQB 120/240 Vac


# of Ampere 120/240 Vac
Poles Rating Wire Range1 Interrupting Rating Product Number
1 10 14-8 Cu/12-8 Al 5kA TQB11103
1 15 14-8 Cu/12-8 Al 10kA THQB11152
1 20 14-8 Cu/12-8 Al 10kA THQB11202
1 25 14-8 Cu/12-8 Al 10kA THQB1125
1 30 14-8 Cu/12-8 Al 10kA THQB1130
1 35 8-3 Cu/8-3 Al 10kA THQB1135
1 40 8-3 Cu/8-3 Al 10kA THQB1140 THQB2115
1 45 8-3 Cu/8-3 Al 10kA THQB1145
1 50 8-3 Cu/8-3 Al 10kA THQB1150
1 60 8-3 Cu/8-3 Al 10kA THQB1160
1 70 6-1/0 Cu/4-1/0 Al 10kA THQB1170

TQB, THQB 120/240 Vac, Internal Common Trip


# of Ampere 120/240 Vac
Poles Rating Wire Range1 Interrupting Rating Product Number
2 10 14-8 Cu/12-8 Al 5kA TQB21103
2 15 14-8 Cu/12-8 Al 10kA THQB2115
2 20 14-8 Cu/12-8 Al 10kA THQB2120
2 25 14-8 Cu/12-8 Al 10kA THQB2125
2 30 14-8 Cu/12-8 Al 10kA THQB2130
2 35 8-3 Cu/8-3 Al 10kA THQB2135
2 40 8-3 Cu/8-3 Al 10kA THQB2140
2 45 8-3 Cu/8-3 Al 10kA THQB2145
2 50 8-3 Cu/8-3 Al 10kA THQB2150
2 60 8-3 Cu/8-3 Al 10kA THQB2160
2 70 6-1/0 Cu/4-1/0 Al 10kA THQB2170
2 80 6-1/0 Cu/4-1/0 Al 10kA THQB2180
2 90 6-1/0 Cu/4-1/0 Al 10kA THQB2190
2 100 6-1/0 Cu/4-1/0 Al 10kA THQB21100

TQB, THQB 240 Vac, Internal Common Trip


# of Ampere 240 Vac
Poles Rating Wire Range1 Interrupting Rating Product Number
2 10 14-8 Cu/12-8 Al 5kA TQB220103
2 15 14-8 Cu/12-8 Al 10kA THQB22015
2 20 14-8 Cu/12-8 Al 10kA THQB22020
2 25 14-8 Cu/12-8 Al 10kA THQB22025
2 30 14-8 Cu/12-8 Al 10kA THQB22030
2 35 8-3 Cu/8-3 Al 10kA THQB22035
2 40 8-3 Cu/8-3 Al 10kA THQB22040
2 45 8-3 Cu/8-3 Al 10kA THQB22045
2 50 8-3 Cu/8-3 Al 10kA THQB22050
2 60 8-3 Cu/8-3 Al 10kA THQB22060
2 70 6-1/0 Cu/4-1/0 Al 10kA THQB22070
2 80 6-1/0 Cu/4-1/0 Al 10kA THQB22080
2 90 6-1/0 Cu/4-1/0 Al 10kA THQB22090
2 100 6-1/0 Cu/4-1/0 Al 10kA THQB22100
3 10 14-8 Cu/12-8 Al 5kA TQB320103
3 15 14-8 Cu/12-8 Al 10kA THQB32015
3 20 14-8 Cu/12-8 Al 10kA THQB32020
3 25 14-8 Cu/12-8 Al 10kA THQB32025
3 30 14-8 Cu/12-8 Al 10kA THQB32030
3 35 8-3 Cu/8-3 Al 10kA THQB32035
3 40 8-3 Cu/8-3 Al 10kA THQB32040
3 45 8-3 Cu/8-3 Al 10kA THQB32045
3 50 8-3 Cu/8-3 Al 10kA THQB32050
3 60 8-3 Cu/8-3 Al 10kA THQB32060
3 70 6-1/0 Cu/4-1/0 Al 10kA THQB32070
3 80 6-1/0 Cu/4-1/0 Al 10kA THQB32080
3 90 6-1/0 Cu/4-1/0 Al 10kA THQB32090
3 100 6-1/0 Cu/4-1/0 Al 10kA THQB32100
1Solid or stranded for 14-10 AWG.
2UL listed as SWD (Switching Duty) rated. Suitable for switching 120 Vac fluorescent lighting loads.
3Not UL listed.
UL listed HACR (heating, air conditioning and refrigeration).

6-20 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Molded Case Circuit Breakers Section 6
Q-Line Circuit Breakers
Bolt-on Circuit Breakers
240V Class

THQB and THHQB 120/240 Vac Arc Fault (Single pole)


# of Ampere 120/240 Vac
Poles Rating Wire Range1 Interrupting Rating Product Number
1 15 14-10 Cu/14-10 Al 10kA THQB1115AF22
1 20 14-10 Cu/14-10 Al 10kA THQB1120AF22
1 15 14-10 Cu/14-10 Al 22kA THHQB1115AF22
1 20 14-10 Cu/14-10 Al 22kA THHQB1120AF22

THQB, THHQB 120 Vac, Ground Fault Circuit Interrupters (5 ma)


# of Ampere 120 Vac
Poles Rating Wire Range1 Interrupting Rating Product Number
1 15 14-8 Cu/12-8 Al 10kA THQB1115GF
1 20 14-8 Cu/12-8 Al 10kA THQB1120GF
1 25 14-8 Cu/12-8 Al 10kA THQB1125GF
1 30 14-8 Cu/12-8 Al 10kA THQB1130GF
1 15 14-8 Cu/12-8 Al 22kA THHQB1115GF
1 20 14-8 Cu/12-8 Al 22kA THHQB1120GF
1 25 14-8 Cu/12-8 Al 22kA THHQB1125GF
1 30 14-8 Cu/12-8 Al 22kA THHQB1130GF

THQB, THHQB 120/240 Vac, Ground Fault Circuit Interrupters, Self Testing, cULus
# of Ampere 120/240 Vac
Poles Rating Wire Range1 Interrupting Rating Product Number THQB1115GF
1 15 14-8Cu/12-8 Al 10kA THQB1115GFT
1 20 14-8Cu/12-8 Al 10kA THQB1120GFT
1 25 14-8 Cu/12-8 Al 10kA THQB1125GFT
1 30 14-8Cu/12-8 Al 10kA THQB1130GFT
1 15 14-8Cu/12-8 Al 22kA THHQB1115GFT
1 20 14-8Cu/12-8 Al 22kA THHQB1120GFT
1 25 14-8 Cu/12-8 Al 22kA THHQB1125GFT
1 30 14-8Cu/12-8 Al 22kA THHQB1130GFT
2 15 14-8Cu/12-8 Al 10kA THQB2115GFT
2 20 14-8Cu/12-8 Al 10kA THQB2120GFT
2 25 14-8 Cu/12-8 Al 10kA THQB2125GFT
2 30 14-8Cu/12-8 Al 10kA THQB2130GFT

THQB 120/240 or 208Y/120 Vac, Ground Fault Circuit Interrupters (5 ma),


Internal Common Trip
# of Ampere 120/240 or 208Y/120 Vac
Poles Rating Wire Range1 Interrupting Rating Product Number
2 15 14-8 Cu/12-8 Al 10kA THQB2115GF
2 20 14-8 Cu/12-8 Al 10kA THQB2120GF
2 25 14-8 Cu/12-8 Al 10kA THQB2125GF
2 30 14-8 Cu/12-8 Al 10kA THQB2130GF

THQB 120 Vac, Ground Fault Circuit Interrupters (30 ma); cULus
# of Ampere 120 Vac
Poles Rating Wire Range1 Interrupting Rating Product Number
1 15 14-8 Cu/12-8 Al 10kA THQB1115GFEP
1 20 14-8 Cu/12-8 Al 10kA THQB1120GFEP
1 30 14-8 Cu/12-8 Al 10kA THQB1130GFEP

THQB 120/240 or 208Y/120 Vac, Ground Fault Circuit Interrupters (30 ma); cULus
Internal Common Trip
# of Ampere 120/240 or 208Y/120 Vac
Poles Rating Wire Range1 Interrupting Rating Product Number
2 15 14-8 Cu/12-8 Al 10kA THQB2115GFEP
2 20 14-8 Cu/12-8 Al 10kA THQB2120GFEP
2 30 14-8 Cu/12-8 Al 10kA THQB2130GFEP
2 40 14-8 Cu/12-8 Al 10kA THQB2140GFEP
1Solid or stranded for 14-10 AWG.
2Combination AFCI compliant with NEC 2008 and later.

Rev. 11/13 www.geindustrial.com BuyLog Catalog 6-21


Data subject to change
without notice
Molded Case Circuit Breakers Section 6
Q-Line Circuit Breakers
Bolt-on Circuit Breakers
240V Class

THQB, THHQB 120/240 Vac, High Intensity Discharge Lighting Loads1


# of Ampere 120/240 Vac
Poles Rating Wire Range2 Interrupting Rating Product Number
1 15 14-8 Cu/12-8 Al 10kA THQB1115HID3
1 20 14-8 Cu/12-8 Al 10kA THQB1120HID3
1 25 14-8 Cu/12-8 Al 10kA THQB1125HID
1 30 14-8 Cu/12-8 Al 10kA THQB1130HID
1 15 14-8 Cu/12-8 Al 22kA THHQB1115HID3
1 20 14-8 Cu/12-8 Al 22kA THHQB1120HID3
1 25 14-8 Cu/12-8 Al 22kA THHQB1125HID
1 30 14-8 Cu/12-8 Al 22kA THHQB1130HID
2 15 14-8 Cu/12-8 Al 10kA THQB2115HID
2 20 14-8 Cu/12-8 Al 10kA THQB2120HID
2 25 14-8 Cu/12-8 Al 10kA THQB2125HID
2 30 14-8 Cu/12-8 Al 10kA THQB2130HID

THHQB 120/240 Vac, Internal Common Trip, High Intensity Discharge Lighting Loads1
# of Ampere 120/240 Vac
Poles Rating Wire Range2 Interrupting Rating Product Number
2 15 14-8 Cu/12-8 Al 22kA THHQB2115HID
2 20 14-8 Cu/12-8 Al 22kA THHQB2120HID
2 25 14-8 Cu/12-8 Al 22kA THHQB2125HID
2 30 14-8 Cu/12-8 Al 22kA THHQB2130HID

THQB 120 Vac with Factory Installed 120 Vac Shunt Trip4,5
# of Ampere 120 Vac
Poles Rating Wire Range2 Interrupting Rating Product Number
1 20 14-8 Cu/12-8 Al 10kA THQB1120ST1

THQB 120 Vac, Internal Common Trip with Factory Installed 120 Vac Shunt Trip4,5
# of Ampere 120 Vac
Poles Rating Wire Range2 Interrupting Rating Product Number
2 20 14-8 Cu/12-8 Al 10kA THQB2120ST1
2 30 14-8 Cu/12-8 Al 10kA THQB2130ST1
2 100 6-1/0 Cu/4-1/0 Al 10kA THQB21100ST1
3 20 14-8 Cu/12-8 Al 10kA THQB32020ST1
3 30 14-8 Cu/12-8 Al 10kA THQB32030ST1
3 35 8-3 Cu/8-3 Al 10kA THQB32035ST1
3 40 8-3 Cu/8-3 Al 10kA THQB32040ST1
3 50 8-3 Cu/8-3 Al 10kA THQB32050ST1
3 60 8-3 Cu/8-3 Al 10kA THQB32060ST1
3 70 6-1/0 Cu/4-1/0 Al 10kA THQB32070ST1
3 80 6-1/0 Cu/4-1/0 Al 10kA THQB32080ST1
3 90 6-1/0 Cu/4-1/0 Al 10kA THQB32090ST1
3 100 6-1/0 Cu/4-1/0 Al 10kA THQB32100ST1

THQB 120 Vac with Switching Neutral Single Thermal Magnetic Pole;
Single Nonautomatic Pole
# of Ampere 120 Vac
Poles Rating Wire Range2 Interrupting Rating Product Number
2 15 14-8 Cu/12-8 Al 10kA THQB21WY15
2 20 14-8 Cu/12-8 Al 10kA THQB21WY20
2 25 14-8 Cu/12-8 Al 10kA THQB21WY25
2 30 14-8 Cu/12-8 Al 10kA THQB21WY30

THQB 120 Vac with Switching Neutral Two Thermal Magnetic Pole;
Single Nonautomatic Pole
# of Ampere 120 Vac
Poles Rating Wire Range2 Interrupting Rating Product Number
3 15 14-8 Cu/12-8 Al 10kA THQB31WY15
3 20 14-8 Cu/12-8 Al 10kA THQB31WY20
3 25 14-8 Cu/12-8 Al 10kA THQB31WY25
3 30 14-8 Cu/12-8 Al 10kA THQB31WY30
1UL listed as HID (high intensity discharge).
2Solid or stranded for 14-10 AWG.
3UL listed as SWD (switching duty). Suitable for switching 120 Vac fluorescent lighting loads.
4For additional shunt trip offerings see page 6-41.

6-22 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Molded Case Circuit Breakers Section 6
Q-Line Circuit Breakers
Bolt-on Circuit Breakers
240V Class

520-60 ampere are UL listed as HACR (heating, air conditioning and refrigeration).

THHQB 120/240 Vac


# of Ampere 120/240 Vac
Poles Rating Wire Range1 Interrupting Rating Product Number
1 15 14-8 Cu/12-8 Al 22kA THHQB11152
1 20 14-8 Cu/12-8 Al 22kA THHQB11202
1 25 14-8 Cu/12-8 Al 22kA THHQB1125
1 30 14-8 Cu/12-8 Al 22kA THHQB1130
1 35 8-3 Cu/8-3 Al 22kA THHQB1135
1 40 8-3 Cu/8-3 Al 22kA THHQB1140
1 45 8-3 Cu/8-3 Al 22kA THHQB1145
1 50 8-3 Cu/8-3 Al 22kA THHQB1150
1 60 8-3 Cu/8-3 Al 22kA THHQB1160
1 70 6-1/0 Cu/4-1/0 Al 22kA THHQB1170

THQB/THHQB 120/240 Vac, Low Magnetic Pickup


# of Ampere 120/240 Vac
Poles Rating Wire Range1 Interrupting Rating Product Number
1 15 14-8 Cu/12-8 Al 10 kA THQB1115LM2
1 20 14-8 Cu/12-8 Al 10 kA THQB1120LM2
1 15 14-8 Cu/12-8 Al 22 kA THHQB1115LM
1 20 14-8 Cu/12-8 Al 22 kA THHQB1120LM
2 15 14-8 Cu/12-8 Al 10 kA THQB2115LM
2 20 14-8 Cu/12-8 Al 10 kA THQB2120LM
2 15 14-8 Cu/12-8 Al 22 kA THHQB2115LM
2 20 14-8 Cu/12-8 Al 22 kA THHQB2120LM

THHQB 120/240 Vac, Internal Common Trip


# of Ampere 120/240 Vac
Poles Rating Wire Range1 Interrupting Rating Product Number
2 15 14-8 Cu/12-8 Al 22kA THHQB2115
2 20 14-8 Cu/12-8 Al 22kA THHQB2120
2 25 14-8 Cu/12-8 Al 22kA THHQB2125
2 30 14-8 Cu/12-8 Al 22kA THHQB2130
2 35 8-3 Cu/8-3 Al 22kA THHQB2135
2 40 8-3 Cu/8-3 Al 22kA THHQB2140
2 45 8-3 Cu/8-3 Al 22kA THHQB2145
2 50 8-3 Cu/8-3 Al 22kA THHQB2150
2 60 8-3 Cu/8-3 Al 22kA THHQB2160
2 70 6-1/0 Cu/4-1/0 Al 22kA THHQB2170 THHQB2115
2 80 6-1/0 Cu/4-1/0 Al 22kA THHQB2180
2 90 6-1/0 Cu/4-1/0 Al 22kA THHQB2190
2 100 6-1/0 Cu/4-1/0 Al 22kA THHQB21100

THHQB 240 Vac, Internal Common Trip


# of Ampere 240 Vac
Poles Rating Wire Range1 Interrupting Rating Product Number
2 15 14-8 Cu/12-8 Al 22kA THHQB22015
2 20 14-8 Cu/12-8 Al 22kA THHQB22020
2 25 14-8 Cu/12-8 Al 22kA THHQB22025
2 30 14-8 Cu/12-8 Al 22kA THHQB22030
2 35 8-3 Cu/8-3 Al 22kA THHQB22035
2 40 8-3 Cu/8-3 Al 22kA THHQB22040
2 45 8-3 Cu/8-3 Al 22kA THHQB22045
2 50 8-3 Cu/8-3 Al 22kA THHQB22050
2 60 8-3 Cu/8-3 Al 22kA THHQB22060
2 70 6-1/0 Cu/4-1/0 Al 22kA THHQB22070
2 80 6-1/0 Cu/4-1/0 Al 22kA THHQB22080
2 90 6-1/0 Cu/4-1/0 Al 22kA THHQB22090
2 100 6-1/0 Cu/4-1/0 Al 22kA THHQB22100
3 15 14-8 Cu/12-8 Al 22kA THHQB32015
3 20 14-8 Cu/12-8 Al 22kA THHQB32020
3 25 14-8 Cu/12-8 Al 22kA THHQB32025
3 30 14-8 Cu/12-8 Al 22kA THHQB32030
3 35 8-3 Cu/8-3 Al 22kA THHQB32035
3 40 8-3 Cu/8-3 Al 22kA THHQB32040
3 45 8-3 Cu/8-3 Al 22kA THHQB32045
3 50 8-3 Cu/8-3 Al 22kA THHQB32050
3 60 8-3 Cu/8-3 Al 22kA THHQB32060
3 70 6-1/0 Cu/4-1/0 Al 22kA THHQB32070
3 80 6-1/0 Cu/4-1/0 Al 22kA THHQB32080
3 90
1Solid or stranded for 14-10 AWG. 6-1/0 Cu/4-1/0 Al 22kA THHQB32090
3 100 6-1/0 Cu/4-1/0 Al 22kA THHQB32100
2UL listed as SWD (switching duty) rated. Suitable for switching 120 Vac fluorescent lighting loads.

UL listed HACR (heating, air conditioning and refrigeration).

Rev. 11/13 www.geindustrial.com BuyLog Catalog 6-23


Data subject to change
without notice
Molded Case Circuit Breakers Section 6
Q-Line Circuit Breakers
Bolt-on Circuit Breakers
240V Class

TXQB 120/240 Vac


# of Ampere 120/240 Vac
Poles Rating Wire Range1 Interrupting Rating Product Number
1 15 14-8 Cu/12-8 Al 65kA TXQB11152
1 20 14-8 Cu/12-8 Al 65kA TXQB11202
1 25 14-8 Cu/12-8 Al 65kA TXQB1125
1 30 14-8 Cu/12-8 Al 65kA TXQB1130

TXQB 120/240 Vac, Internal Common Trip


# of Ampere 120/240 Vac
Poles Rating Wire Range1 Interrupting Rating Product Number
2 15 14-8 Cu/12-8 Al 65kA TXQB2115
2 20 14-8 Cu/12-8 Al 65kA TXQB2120
2 25 14-8 Cu/12-8 Al 65kA TXQB2125
2 30 14-8 Cu/12-8 Al 65kA TXQB2130

TXQB 240 Vac, Internal Common Trip


# of Ampere 240 Vac
Poles Rating Wire Range1 Interrupting Rating Product Number
3 15 14-8 Cu/12-8 Al 65kA TXQB32015
3 20 14-8 Cu/12-8 Al 65kA TXQB32020
3 25 14-8 Cu/12-8 Al 65kA TXQB32025
3 30 14-8 Cu/12-8 Al 65kA TXQB32030
1Solid or stranded for 14-10 AWG.
2UL listed as SWD (switching duty) rated. Suitable for switching 120 Vac fluorescent lighting loads.

UL listed HACR (heating, air conditioning and refrigeration).

6-24 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Molded Case Circuit Breakers Section 6
Q-Line Circuit Breakers
Cable-in Cable-out (lug-lug)
240V Class

TQC, THQC, THHQC 120/240 Vac


# of Ampere 120/240 Vac 120/240 Vac
Poles Rating Wire Range1 Interrupting Rating Product Number2 Interrupting Rating Product Number2
1 10 14-4 Cu/12-2 Al 5kA TQC1110WL
1 15 14-8 Cu/12-8 Al 10kA THQC1115WL3,4 22kA THHQC1115WL3
1 20 14-8 Cu/12-8 Al 10kA THQC1120WL3,4 22kA THHQC1120WL3
1 25 14-8 Cu/12-8 Al 10kA THQC1125WL3 22kA THHQC1125WL3
1 30 14-8 Cu/12-8 Al 10kA THQC1130WL3 22kA THHQC1130WL3
1 35 8-3 Cu/8-3 Al 10kA THQC1135WL3 22kA THHQC1135WL3
1 40 8-3 Cu/8-3 Al 10kA THQC1140WL3 22kA THHQC1140WL3
1 45 8-3 Cu/8-3 Al 10kA THQC1145WL3 22kA THHQC1145WL3
1 50 8-3 Cu/8-3 Al 10kA THQC1150WL3 22kA THHQC1150WL3
1 60 8-3 Cu/8-3 Al 10kA THQC1160WL3 22kA THHQC1160WL3
1 70 6-1/0 Cu/4-1/0 Al 10kA THQC1170WL 22kA THHQC1170WL

TQC, THQC, THHQC 120/240 Vac, Internal Common Trip


# of Ampere 120/240 Vac 120/240 Vac
Poles Rating Wire Range1 Interrupting Rating Product Number2 Interrupting Rating Product Number2
2 10 14-4 Cu/12-2 Al 5kA TQC2110WL
2 15 14-8 Cu/12-8 Al 10kA THQC2115WL3 22kA THHQC2115WL3
2 20 14-8 Cu/12-8 Al 10kA THQC2120WL3 22kA THHQC2120WL3
2 25 14-8 Cu/12-8 Al 10kA THQC2125WL3
2 30 14-8 Cu/12-8 Al 10kA THQC2130WL3 22kA THHQC2130WL3
2 35 8-3 Cu/8-3 Al 10kA THQC2135WL3 22kA THHQC2135WL3
2 40 8-3 Cu/8-3 Al 10kA THQC2140WL3 22kA THHQC2140WL3
2 45 8-3 Cu/8-3 Al 10kA THQC2145WL3 22kA THHQC2145WL3
2 50 8-3 Cu/8-3 Al 10kA THQC2150WL3 22kA THHQC2150WL3
2 60 8-3 Cu/8-3 Al 10kA THQC2160WL3 22kA THHQC2160WL3
2 70 6-1/0 Cu/4-1/0 Al 10kA THQC2170WL 22kA THHQC2170WL
2 80 6-1/0 Cu/4-1/0 Al 10kA THQC2180WL 22kA THHQC2180WL
2 90 6-1/0 Cu/4-1/0 Al 10kA THQC2190WL 22kA THHQC2190WL
2 100 6-1/0 Cu/4-1/0 Al 10kA THQC21100WL 22kA THHQC21100WL

TQC, THQC, THHQC 240 Vac, Internal Common Trip


# of Ampere 240 Vac 240 Vac
Poles Rating Wire Range1 Interrupting Rating Product Number2 Interrupting Rating Product Number
2 10 14-4 Cu/12-2 Al 5kA TQC22010WL
2 15 14-8 Cu/12-8 Al 10kA THQC22015WL 22kA THHQC22015WL
2 20 14-8 Cu/12-8 Al 10kA THQC22020WL 22kA THHQC22020WL
2 25 14-8 Cu/12-8 Al 10kA THQC22025WL 22kA THHQC22025WL
2 30 14-8 Cu/12-8 Al 10kA THQC22030WL 22kA THHQC22030WL
2 35 8-3 Cu/8-3 Al 10kA THQC22035WL 22kA THHQC22035WL
2 40 8-3 Cu/8-3 Al 10kA THQC22040WL 22kA THHQC22040WL
2 45 8-3 Cu/8-3 Al 10kA THQC22045WL 22kA THHQC22045WL
2 50 8-3 Cu/8-3 Al 10kA THQC22050WL 22kA THHQC22050WL
2 60 8-3 Cu/8-3 Al 10kA THQC22060WL 22kA THHQC22060WL
2 70 6-1/0 Cu/4-1/0 Al 10kA THQC22070WL 22kA THHQC22070WL
2 80 6-1/0 Cu/4-1/0 Al 10kA THQC22080WL 22kA THHQC22080WL
2 90 6-1/0 Cu/4-1/0 Al 10kA THQC22090WL 22kA THHQC22090WL
2 100 6-1/0 Cu/4-1/0 Al 10kA THQC22100WL 22kA THHQC22100WL
3 10 14-4 Cu/12-2 Al 5kA TQC32010WL
3 15 14-8 Cu/12-8 Al 10kA THQC32015WL 22kA THHQC32015WL
3 20 14-8 Cu/12-8 Al 10kA THQC32020WL 22kA THHQC32020WL
3 25 14-8 Cu/12-8 Al 10kA THQC32025WL 22kA THHQC32025WL
3 30 14-8 Cu/12-8 Al 10kA THQC32030WL 22kA THHQC32030WL
3 35 8-3 Cu/8-3 Al 10kA THQC32035WL 22kA THHQC32035WL
3 40 8-3 Cu/8-3 Al 10kA THQC32040WL 22kA THHQC32040WL
3 45 8-3 Cu/8-3 Al 10kA THQC32045WL 22kA THHQC32045WL
3 50 8-3 Cu/8-3 Al 10kA THQC32050WL 22kA THHQC32050WL
3 60 8-3 Cu/8-3 Al 10kA THQC32060WL 22kA THHQC32060WL
3 70 6-1/0 Cu/4-1/0 Al 10kA THQC32070WL 22kA THHQC32070WL
3 80 6-1/0 Cu/4-1/0 Al 10kA THQC32080WL 22kA THHQC32080WL
3 90 6-1/0 Cu/4-1/0 Al 10kA THQC32090WL 22kA THHQC32090WL
3 100 6-1/0 Cu/4-1/0 Al 10kA THQC32100WL 22kA THHQC32100WL
1Solid or stranded for 14-10 AWG.
2Use additional suffix BP (THQC32020WLBP) for bulk pack of 48 poles. Carton weight 20 lbs. 15-60 ampere breakers only.
3Suitable for mounting on standard 35mm DIN Rail. Refer to table on page 6-27 for termination options.
4UL listed as SWD (switching duty) rated. Suitable for switching 120 Vac fluorescent lighting loads.

UL listed HACR (heating, air conditioning and refrigeration). Refer to Q-Line accessories listed on pages 6-30 to 6-31.

Rev. 11/13 www.geindustrial.com BuyLog Catalog 6-25


Data subject to change
without notice
Molded Case Circuit Breakers Section 6
Q-Line Circuit Breakers
Cable-in Cable-out (lug-lug)
240V Class

THQC 120 Vac, Ground Fault Circuit Interrupters


# of Ampere 120 Vac
Poles Rating Wire Range1 Interrupting Rating Product Number
1 15 14-8 Cu/12-8 Al 10kA THQC1115GF2
1 20 14-8 Cu/12-8 Al 10kA THQC1120GF2
1 25 14-8 Cu/12-8 Al 10kA THQC1125GF2
1 30 14-8 Cu/12-8 Al 10kA THQC1130GF2

THQC 120/240 Vac Ground Fault Circuit Interrupters, Self-Testing


# of Ampere 120 Vac
Poles Rating Wire Range1 Interrupting Rating Product Number
1 15 14-8Cu/12-8 Al 10kA THQC1115GFT
1 20 14-8Cu/12-8 Al 10kA THQC1120GFT
1 25 14-8 Cu/12-8 Al 10kA THQC1125GFT
1 30 14-8Cu/12-8 Al 10kA THQC1130GFT
2 15 14-8 Cu/12-8 Al 10kA THQC2115GFT
2 20 14-8 Cu/12-8 Al 10kA THQC2120GFT THQC1120GF
2 25 14-8 Cu/12-8 Al 10kA THQC2125GFT
2 30 14-8 Cu/12-8 Al 10kA THQC2130GFT

TXQC 120/240 Vac


# of Ampere 120/240 Vac
Poles Rating Wire Range1 Interrupting Rating Product Number
1 15 14-8 Cu/12-8 Al 65kA TXQC1115WL
1 20 14-8 Cu/12-8 Al 65kA TXQC1120WL
1 25 14-8 Cu/12-8 Al 65kA TXQC1125WL
1 30 14-8 Cu/12-8 Al 65kA TXQC1130WL

TXQC 120/240 Vac, Internal Common Trip


# of Ampere 120/240 Vac
Poles Rating Wire Range1 Interrupting Rating Product Number
2 15 14-8 Cu/12-8 Al 65kA TXQC2115WL
2 20 14-8 Cu/12-8 Al 65kA TXQC2120WL
2 25 14-8 Cu/12-8 Al 65kA TXQC2125WL
2 30 14-8 Cu/12-8 Al 65kA TXQC2130WL
THQC1115GFT

TXQC 240 Vac, Internal Common Trip


# of Ampere 120/240 Vac
Poles Rating Wire Range1 Interrupting Rating Product Number
3 15 14-8 Cu/12-8 Al 65kA TXQC32015WL
3 20 14-8 Cu/12-8 Al 65kA TXQC32020WL
3 25 14-8 Cu/12-8 Al 65kA TXQC32025WL
3 30 14-8 Cu/12-8 Al 65kA TXQC32030WL
1Solid or stranded for 14-10 AWG.
2Requires mounting plate. See page 6-30. Not suitable for use in GE column panels.

UL listed HACR (heating, air conditioning and refrigeration).


Use Q-Line mounting accessories listed on pages 6-30 to 6-31.

6-26 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Molded Case Circuit Breakers Section 6
Q-Line Circuit Breakers
DIN-Rail Mount
240V Class

Product Features
Multi-terminal Configuration Breakers
35 mm DIN rail mounting
Optional front/rear panel mounting kitsTHQCFMK, page 6-30.
Optional load end terminal for up to (4) 0.25-inch quick connnects.
Contact local GE sales office for ring terminal configurationsnot DIN rail compatible.

THQC, THHQC 120/240 Vac


Product Number
# of Ampere 120/240 Vac Product Number Line TQAL3A and Product Number
Poles Rating Interrupting Rating No Lugs Load THQECC Line TQAL3A, Load N/A
1 15 10kA THQC1115LL1 THQC1115CC1 THQC1115X21
1 20 10kA THQC1120LL1 THQC1120CC1 THQC1120X21
1 25 10kA THQC1125LL THQC1125CC THQC1125X2
1 30 10kA THQC1130LL THQC1130CC THQC1130X2
1 35 10kA THQC1135LL THQC1135CC THQC1135X2
1 40 10kA THQC1140LL THQC1140CC THQC1140X2
1 45 10kA THQC1145LL THQC1145CC THQC1145X2
1 50 10kA THQC1150LL THQC1150CC THQC1150X2
1 60 10kA THQC1160LL THQC1160CC THQC1160X2
1 15 22kA THHQC1115LL THHQC1115CC THHQC1115X2
1 20 22kA THHQC1120LL THHQC1120CC THHQC1120X2
1 25 22kA THHQC1125LL THHQC1125CC THHQC1125X2
1 30 22kA THHQC1130LL THHQC1130CC THHQC1130X2
1 35 22kA THHQC1135LL THHQC1135CC THHQC1135X2
1 40 22kA THHQC1140LL THHQC1140CC THHQC1140X2
1 45 22kA THHQC1145LL THHQC1145CC THHQC1145X2
1 50 22kA THHQC1150LL THHQC1150CC THHQC1150X2
1 60 22kA THHQC1160LL THHQC1160CC THHQC1160X2

15-60A UL Listed HACR (heating, air conditioning and refrigeration)

THQC, THHQC 120/240 Vac, Internal Common Trip


Product Number
# of Ampere 120/240 Vac Product Number Line TQAL3A and Product Number
Poles Rating Interrupting Rating No Lugs Load THQECC Line TQAL3A, Load N/A
2 15 10kA THQC2115LL1 THQC2115CC1 THQC2115X21
2 20 10kA THQC2120LL1 THQC2120CC1 THQC2120X21
2 25 10kA THQC2125LL THQC2125CC THQC2125X2
2 30 10kA THQC2130LL THQC2130CC THQC2130X2
2 35 10kA THQC2135LL THQC2135CC THQC2135X2
2 40 10kA THQC2140LL THQC2140CC THQC2140X2
2 45 10kA THQC2145LL THQC2145CC THQC2145X2
2 50 10kA THQC2150LL THQC2150CC THQC2150X2
2 60 10kA THQC2160LL THQC2160CC THQC2160X2
2 15 22kA THHQC2115LL THHQC2115CC THHQC2115X2
2 20 22kA THHQC2120LL THHQC2120CC THHQC2120X2
2 25 22kA THHQC2125LL THHQC2125CC THHQC2125X2
2 30 22kA THHQC2130LL THHQC2130CC THHQC2130X2
2 35 22kA THHQC2135LL THHQC2135CC THHQC2135X2
2 40 22kA THHQC2140LL THHQC2140CC THHQC2140X2
2 45 22kA THHQC2145LL THHQC2145CC THHQC2145X2
2 50 22kA THHQC2150LL THHQC2150CC THHQC2150X2
2 60 22kA THHQC2160LL THHQC2160CC THHQC2160X2

15-60A UL Listed HACR (heating, air conditioning and refrigeration)

Terminal Configuration Terminal Selection


Suffix2 Line Terminal Load Terminal Type Wire Range Product Number
WL TQAL3A THQEL3 LugLine only 14-6 Cu/12-2 Al TQAL3A
X2 TQAL3A N/A LugLoad only 14-2 Cu/12-2 Al THQEL3
LL N/A N/A Quick ConnectorLoad only (4) 14 Cu or (4) 12 Al THQECC
CC TQAL3A THQECC
None N/A THQEL3
115 and 20 ampere breakers UL listed as SWD (Switching Duty) rated. Suitable for
switching 120 Vac fluorescent lighting loads.
2Use additional suffix BP (THQC1120CCBP) for bulk pack of 48 poles. Must be
ordered in multiples of 48 poles.
Additional Q-Line mounting accessories listed on pages 6-30 to 6-31.

Rev. 11/13 www.geindustrial.com BuyLog Catalog 6-27


Data subject to change
without notice
Molded Case Circuit Breakers Section 6
Q-Line Circuit Breakers
Cable-in Cable-out (lug-lug)
240V Class

TQD 240 Vac, Internal Common Trip


# of Ampere 240 Vac
Poles Rating Interrupting Rating Product Number 1,2
2 100 10kA TQD22100WL
2 125 10kA TQD22125WL
2 150 10kA TQD22150WL
2 175 10kA TQD22175WL
2 200 10kA TQD22200WL
2 225 10kA TQD22225WL
3 100 10kA TQD32100WL
3 125 10kA TQD32125WL
3 150 10kA TQD32150WL
3 175 10kA TQD32175WL TJD432400WL
3 200 10kA TQD32200WL
3 225 10kA TQD32225WL

TQD 240 Vac, Internal Common Trip with Factory Installed 120 Vac Shunt Trip3
# of Ampere 240 Vac
Poles Rating Interrupting Rating Product Number 1,2
3 125 10kA TQD32125ST1
3 150 10kA TQD32150ST1
3 175 10kA TQD32175ST1
3 200 10kA TQD32200ST1
3 225 10kA TQD32225ST1

THQD 240 Vac, Internal Common Trip


# of Ampere 240 Vac
Poles Rating Interrupting Rating Product Number 1,2
2 100 22kA THQD22100WL
2 125 22kA THQD22125WL
2 150 22kA THQD22150WL
2 175 22kA THQD22175WL
2 200 22kA THQD22200WL
2 225 22kA THQD22225WL
3 100 22kA THQD32100WL
3 125 22kA THQD32125WL
3 150 22kA THQD32150WL
3 175 22kA THQD32175WL
3 200 22kA THQD32200WL
3 225 22kA THQD32225WL

TJD 240 Vac, Internal Common Trip


# of Ampere 240 Vac
Poles Rating Interrupting Rating Product Number 1,2
2 250 22kA TJD422250WL
2 300 22kA TJD422300WL
2 350 22kA TJD422350WL
2 400 22kA TJD422400WL
2 400 Molded Case Switch 22kA TJD422Y400
3 250 22kA TJD432250WL4
3 300 22kA TJD432300WL4
3 350 22kA TJD432350WL4
3 400 22kA TJD432400WL4
3 400 Molded Case Switch 22kA TJD432Y4004
1Refer to table on page 6-103 for lug and wire range data.
2Includes line and load lugs. For optional configurations see page 6-3.
3For additional shunt trip options see page 6-41.
4TJD uses same accessories as J600 line. TJD not listed HACR.

UL listed HACR (heating, air conditioning and refrigeration).

6-28 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Molded Case Circuit Breakers Section 6
Q-Line Circuit Breakers
Molded Case Switches
240V Class
Note: Molded case switches may be used as main devices in panelboards and switch-
boards but cannot be used as subfeeds or branch breakers because they do not provide
wire protection. Q-Line and TEB molded case switches have a 10,000 ampere symmetrical
short circuit withstand rating when protected by a fuse or circuit breaker rated 10,000
amperes IC or greater and whose ampere rating does not exceed the ampere rating of
the switch.

Plug-in TQL 120/240, Vac Internal Common Trip


# of Ampere 120/240 Vac
Poles Rating Wire Range1 Short Circuit Withstand Rating Product Number
2 60 8-3 Cu/8-3 Al 10kA TQL21Y60
2 100 6-1/0 Cu/4-1/0 Al 10kA TQL21Y100

Plug-in TQL 240, Vac Internal Common Trip


# of Ampere 240 Vac
Poles Rating Wire Range1 Short Circuit Withstand Rating Product Number
2 60 8-3 Cu/8-3 Al 10kA TQL22Y60
2 100 6-1/0 Cu/4-1/0 Al 10kA TQL22Y100
3 60 8-3 Cu/8-3 Al 10kA TQL32Y60
3 100 6-1/0 Cu/4-1/0 Al 10kA TQL32Y100

Bolt-on TQB 120/240, Vac Internal Common Trip


# of Ampere 120/240 Vac
Poles Rating Wire Range1 Short Circuit Withstand Rating Product Number
2 60 8-3 Cu/8-3 Al 10kA TQB21Y60
2 100 6-1/0 Cu/4-1/0 Al 10kA TQB21Y100

Bolt-on TQB 240 Vac, Internal Common Trip


# of Ampere 240 Vac
Poles Rating Wire Range1 Short Circuit Withstand Rating Product Number
2 60 8-3 Cu/8-3 Al 10kA TQB22Y60
2 100 6-1/0 Cu/4-1/0 Al 10kA TQB22Y100
3 60 8-3 Cu/8-3 Al 10kA TQB32Y60
3 100 6-1/0 Cu/4-1/0 Al 10kA TQB32Y100

Cable In-Cable Out (Lug-Lug) TQC 120/240 Vac, Internal Common Trip
# of Ampere 120/240 Vac
Poles Rating Wire Range1 Short Circuit Withstand Rating Product Number
2 60 8-3 Cu/8-3 Al 10kA TQC21Y60
2 100 6-1/0 Cu/4-1/0 Al 10kA TQC21Y100

Cable In-Cable Out (Lug-Lug) TQC 240 Vac, Internal Common Trip
# of Ampere 240 Vac
Poles Rating Wire Range1 Short Circuit Withstand Rating Product Number
2 60 8-3 Cu/8-3 Al 10kA TQC22Y60
2 100 6-1/0 Cu/4-1/0 Al 10kA TQC22Y100
3 60 8-3 Cu/8-3 Al 10kA TQB32Y60
3 100 6-1/0 Cu/4-1/0 Al 10kA TQB32Y100

Cable In-Cable Out (Lug-Lug) TQD, TJD 240 Vac, Internal Common Trip
# of Ampere 240 Vac
Poles Rating Short Circuit Withstand Rating Product Number 4
2 225 14kA TQD22Y225
3 225 14kA TQD32Y2252
2 400 22kA TJD422Y400
3 400 22kA TJD432Y4003
1Solid or stranded for 14-10 AWG.
2TQD32YT225 with dummy trip used for accessorized applications.
3TJD uses same accessories as J600 line.
4Refer to table on page 6-106 for lug and wire range data. Line and load lugs included in basic switch product number.

Rev. 11/13 www.geindustrial.com BuyLog Catalog 6-29


Data subject to change
without notice
Molded Case Circuit Breakers Section 6
Q-Line Circuit Breakers
Accessories
240V Class

Terminals (Lugs) for Q-Line Circuit Breakers


Ampere Rating Termination Type Wire Range (Cu/Al) Product Number
15-60 Lug (line only) 14-6/12-2 TQAL3A
15-60 Lug (load only) 14-2/12-2 THQEL3
15-60 Quick connector (load only) (4) 14/(4) 12 THQECC

Mounting Accessories for THQB, THQC Quick Connector THQECC


Product Ampere # of Used With
Type Rating Poles Frame Product Number
Bolt-on Mounting Base 3 THQB/TEY TEY3B
Back Mounting Plates 1 THQC TQCBMPA1
Screw Type
Back Mounting Plates 2 THQC TQCBMPA2
Screw Type
Back Mounting Plates 3 THQC TQCBMPA3
Screw Type
Back Mounting Plates 10 THQC TQCBMPA10
Screw Type
Front-mounting Plates 1 THQC TQCFMP11
Front-mounting Plates 2 THQC TQCFMP21
Front-mounting Plates 3 THQC TQCFMP31
Front-mounting Plates 4 THQC TQCFMP41
Load Lug THQEL3
1 & 2-pole
Pack of 48 Front/Rear Mounting Clips THQC THQCFMK
15-60A
Pack of 24 DIN rail clips THQC THQCDIN
1Not UL listed.

Mounting Accessories for THQC, THQC-GF, GFEP

Product Type # of Poles Used With Frame Product Number


Snap In Back 1 THQC, THQC-GF TQCGFBMPA1
Mounting Plates
Snap In Back 2 THQC, THQC-GF TQCGFBMPA2
Mounting Plates
Snap In Back 3 THQC, THQC-GF TQCGFBMPA3
Mounting Plates
Snap In Back 10 THQC, THQC-GF TQCGFBMPA10
Mounting Plates

Mounting Kit THQCFMK


Mounting Accessories for TQL
Product Ampere # of Used With
Type Rating Poles Frame Product Number
Plug-in Mounting Base 70 amp 2 TQL 571B595DDG1
Plug-in Mounting Base 70 amp 3 TQL 571B595DDG2
Plug-in Mounting Base 100 amp 3 TQL 565B837G1
Plug-in Mounting Base 100 amp 2 TQL 565B837G2

6-30 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Molded Case Circuit Breakers Section 6
Q-Line Circuit Breakers
Accessories

Handle Locking Devices & Handle Ties


Description Breaker Type Product Number
TQB
Handle Locks - Non Padlocking TQC THL1035
TQL
TQB GF
Handle Locks - Padlocking TQC GF THQGFPLD12,4
TQL GF
THQP
TQB GF
Handle Locks - Non Padlocking
TQC GF
TQPL THL103
TQL GF
Handle Locks - Padlocking TQD TQDPLD12
Handle Locks - Padlocking TQD TQPDLD21
TQB
Handle Locks - Padlocking THP100
TQL
Handle Locks - Padlocking THQP TQPPL
Handle Locks - Padlocking TQC TQPLD12
TQB
Snap-on Handle Tie - Trip Indicating TQC TQHT16
TQL
TQB
Snap-on Handle Tie - Solid TQC THT1046
TQL
TQB
Multiwire Branch Breaker TQ3HTK7
TQC
Handle Tie Kits TQ4HTK8
TQL

All multi-pole breakers have internal common trip


Handle ties provide manual on-off capability only between one-pole devices THP100

Breaker Mounting Screw Kit


Product Type Used With Frame Product Number
Breaker Mounting Screw Kit THQB TQBS13
1EUSERC ApprovedFactory Installed Only.
2Suitable for circuit breakers used in group mounted panelboard construction only.
3Price is per screw. Packaged in quantities of 24. Must be ordered in multiples of 24.
4Suitable for use on single pole GF Breakers only.
5Kit includes (1) lock for 1-pole breaker and (1) lock for 2-pole breaker
6For two single-pole breakers
7For three single-pole breakers - kit includes (10) pcs.
8For four single-pole breakers - kit includes (10) pcs.
THT104

TQHT1

Rev. 11/13 www.geindustrial.com BuyLog Catalog 6-31


Data subject to change
without notice
Molded Case Circuit Breakers Section 6
Industrial Circuit Breakers
15-100A
Thermal Magnetic Trip
Type TEY/TEYF
Noninterchangeable Trip
Bolt-on
480Y/277V Class

TEY and TEYF breakers are one-inch wide per pole, compact, bolt-on circuit breakers
for use on grounded 480Y/277 Vac systems. Short circuit ratings at that voltage for TEY
and TEYF are 14 and 18kA, respectively. TEYF also offers higher selectivity ratings with
upstream devices (See DET-537 for details). The bolt-on mounting base (TEY3B) shown
on page 6-102 makes TEY and TEYF suitable for various lug-lug applications.
TEY/TEYF (UL File E-11592; CSA LR 57114)
Ampere
Rating Wire Range1 Product Number Product Number
Type TEY3,4 Type TEYF3,4
Single Pole - Includes Integral Cu/Al Load Lugs 14kA @ 277 Vac 18kA @ 277 Vac
15 #14-#10 TEY1152 TEYF1152
20 #14-#10 TEY1202 TEYF1202
25 #14-#10 TEY125 TEYF125
30 #14-#10 TEY130 TEYF130
35 #10-#4 TEY135 TEYF135
40 #10-#4 TEY140 TEYF140 1- 2- and 3-pole TEY/TEYF breakers
45 #10-#4 TEY145 TEYF145
50 #10-#4 TEY150 TEYF150
60 #10-#4 TEY160 TEYF160
70 #4-1/0 TEY170
80 #4-1/0 TEY180
90 #4-1/0 TEY190
100 #4-1/0 TEY1100
Type TEY3,4 Type TEYF3,4
Two-Pole - Includes Integral Cu/Al Load Lugs 14kA @ 480 / 277 Vac 18kA @ 480 / 277 Vac
15 #14-#10 TEY215 TEYF215
20 #14-#10 TEY220 TEYF220
25 #14-#10 TEY225 TEYF225
30 #14-#10 TEY230 TEYF230
35 #10-#4 TEY235 TEYF235
40 #10-#4 TEY240 TEYF240
45 #10-#4 TEY245 TEYF245
50 #10-#4 TEY250 TEYF250
60 #10-#4 TEY260 TEYF260
70 #4-1/0 TEY270 TEYF270
80 #4-1/0 TEY280 TEYF280
90 #4-1/0 TEY290 TEYF290
100 #4-1/0 TEY2100 TEYF2100
110 #4-2/0 TEYF2110B
125 #4-2/0 TEYF2125B
Type TEY3,4 Type TEYF3,4
Three-Pole - Includes Integral Cu/Al Load Lugs 14kA @ 480 / 277 Vac 18kA @ 480 / 277 Vac
15 #14-#10 TEY315 TEYF315
20 #14-#10 TEY320 TEYF320
25 #14-#10 TEY325 TEYF325
30 #14-#10 TEY330 TEYF330
35 #10-#4 TEY335 TEYF335
40 #10-#4 TEY340 TEYF340
45 #10-#4 TEY345 TEYF345
50 #10-#4 TEY350 TEYF350
60 #10-#4 TEY360 TEYF360
70 #4-1/0 TEY370 TEYF370
80 #4-1/0 TEY380 TEYF380
90 #4-1/0 TEY390 TEYF390
100 #4-1/0 TEY3100 TEYF3100
110 #4-2/0 TEYF3110B
125 #4-2/0 TEYF3125B
1Solid or stranded for 14-10 AWG.
2Single-pole, 15 and 20 ampere breakers are also UL listed as switching duty breakers, suitable for switching
120, 240, or 277 Vac.
3UL listed HACR (Heating, Air Conditioning, Refrigeration).
4UL listed for HID (high intensity discharge), all 50A or less.

Internal Accessories for TEY/TEYF (2- and 3-pole breaker only) Factory Installed Only
Auxiliary Switch, Single-Pole Add suffix to Breaker
(5A at 120, 240, 277 Vac, 1/4 hp at 120, 240 Vdc) Product Number
A switch (normally open) AS1A5
B switch (normally closed) AS1B5
AB switch (both) ASAB5
Shunt Trip 120-277 Vac control voltage ST125
5Limited to one accessory per breaker.

6-32 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Molded Case Circuit Breakers Section 6
Industrial Circuit Breakers
15-125A
Thermal Magnetic Trip
Type TEYD/TEYH/TEYL
Noninterchangeable Trip
Bolt-on
480Y/277V Class

The TEY family of circuit breakers (TEY, TEYF, TEYD, TEYH, and TEYL) are one-inch wide per
pole, compact, bolt-on circuit breakers for use on grounded 480Y/277 Vac systems, and
are typically installed within Lighting Panelboards, including GE A-Series. Short circuit
ratings at 480/277 Vac are shown in the tables that follow. Ratings at other voltages are
shown in the Quick Reference Guide at the beginning of this section. Bolt-On mounting
bases TEY3B (page 6-102) and TEY3B125 (page 6-34) make these frames suitable for
unit mount / lug-lug connected applications. Handle tie kits, suitable for use with multiple
single pole breakers used on shared neutral circuits (page 6-34) are available for
TEYD/H/L circuit breakers.

TEYD/TEYH/TEYL (UL/cUL File E-11592)


Ampere Wire
Rating Range1 Product No. Product No. Product No.
Single Pole Type TEYD Type TEYH Type TEYL
Includes Load Lugs 25kA @ 480 / 277 Vac 35kA @ 480 / 277 Vac 65kA @ 480 / 277 Vac 1- 2- and 3-pole
15 #14-#10 TEYD1015B TEYH1015B TEYL1015B TEYD/TEYH/TEYL breakers
20 #14-#10 TEYD1020B TEYH1020B TEYL1020B
25 #10-#4 TEYD1025B TEYH1025B TEYL1025B
30 #10-#4 TEYD1030B TEYH1030B TEYL1030B
35 #10-#4 TEYD1035B TEYH1035B TEYL1035B
40 #10-#4 TEYD1040B TEYH1040B TEYL1040B
45 #10-#4 TEYD1045B TEYH1045B TEYL1045B
50 #10-#4 TEYD1050B TEYH1050B TEYL1050B
60 #10-#4 TEYD1060B TEYH1060B TEYL1060B
70 #4-2/0 TEYD1070B TEYH1070B TEYL1070B
Two-Pole Type TEYD Type TEYH Type TEYL
Includes Load Lugs 25kA @ 480 / 277 Vac 35kA @ 480 / 277 Vac 65kA @ 480 / 277 Vac
15 #14-10 TEYD2015B TEYH2015B TEYL2015B
20 #14-10 TEYD2020B TEYH2020B TEYL2020B
25 #10-#4 TEYD2025B TEYH2025B TEYL2025B
30 #10-#4 TEYD2030B TEYH2030B TEYL2030B
35 #10-#4 TEYD2035B TEYH2035B TEYL2035B
40 #10-#4 TEYD2040B TEYH2040B TEYL2040B
45 #10-#4 TEYD2045B TEYH2045B TEYL2045B
50 #10-#4 TEYD2050B TEYH2050B TEYL2050B
60 #10-#4 TEYD2060B TEYH2060B TEYL2060B
70 #4-2/0 TEYD2070B TEYH2070B TEYL2070B
80 #4-2/0 TEYD2080B TEYH2080B TEYL2080B
90 #4-2/0 TEYD2090B TEYH2090B TEYL2090B
100 #4-2/0 TEYD2100B TEYH2100B TEYL2100B
110 #4-2/0 TEYD2110B TEYH2110B TEYL2110B
125 #4-2/0 TEYD2125B TEYH2125B TEYL2125B
Three-Pole Type TEYD Type TEYH Type TEYL
Includes Load Lugs 25kA @ 480 / 277 Vac 35kA @ 480 / 277 Vac 65kA @ 480 / 277 Vac
15 #14-#10 TEYD3015B TEYH3015B TEYL3015B
20 #14-#10 TEYD3020B TEYH3020B TEYL3020B
25 #10-#4 TEYD3025B TEYH3025B TEYL3025B
30 #10-#4 TEYD3030B TEYH3030B TEYL3030B
35 #10-#4 TEYD3035B TEYH3035B TEYL3035B
40 #10-#4 TEYD3040B TEYH3040B TEYL3040B
45 #10-#4 TEYD3045B TEYH3045B TEYL3045B
50 #10-#4 TEYD3050B TEYH3050B TEYL3050B
60 #10-#4 TEYD3060B TEYH3060B TEYL3060B
70 #4-2/0 TEYD3070B TEYH3070B TEYL3070B
80 #4-2/0 TEYD3080B TEYH3080B TEYL3080B
90 #4-2/0 TEYD3090B TEYH3090B TEYL3090B
100 #4-2/0 TEYD3100B TEYH3100B TEYL3100B
110 #4-2/0 TEYD3110B TEYH3110B TEYL3110B
125 #4-2/0 TEYD3125B TEYH3125B TEYL3125B
1Solid or stranded for 14-10 AWG.
2Single-pole, 15 and 20 ampere breakers are also UL listed as switching duty breakers, suitable for switching
120, 240, or 277 Vac.
3UL listed HACR (Heating, Air Conditioning, Refrigeration).
4UL listed for HID (high intensity discharge), all 50A or less.

Rev. 11/13 www.geindustrial.com BuyLog Catalog 6-33


Data subject to change
without notice
Molded Case Circuit Breakers Section 6
Industrial Circuit Breakers
15-125A
Thermal Magnetic Trip
Type TEYD/TEYH/TEYL
Noninterchangeable Trip
Bolt-on
480Y/277V Class

Internal Accessories for TEYD/TEYH/TEYL - Factory Installed Only


Description Product Number
TEYD/H/L UV Release1,3
24 Vac TEYXU1
48 Vac TEYXU2
120 Vac TEYXU3
240 Vac TEYXU4
24 Vdc TEYXU6
48 Vdc TEYXU7
125 Vdc TEYXU8
250 Vdc TEYXU9
TEYD/H/L Shunt Trip1
24 Vac TEYXS1
48 Vac TEYXS2
120 Vac TEYXS3
240 Vac TEYXS4
24 Vdc TEYXS6
48 Vdc TEYXS7
125 Vdc TEYXS8
250 Vdc TEYXS9
TEYD/H/L Auxiliary Switch2
LT Pole TEYXASL
RT Pole TEYXASR
Bell Alarm
TEYD/H/L Bell Alarm - Form C1 TEYXBA1
TEYD/H/L Mounting Base
3-P 15-100A Mounting Base TEY3B
3-P 110/125A Mounting Base TEY3B125
TEYD/H/L Handle Tie
TEYD/H/L 2-Pole Handle Tie TEYXHT2
10-Pack TEYD/H/L 2-Pole Handle Tie (10 Pack) TEYXHT2K
TEYD/H/L 3-Pole Handle Tie TEYXHT3
10-Pack TEYD/H/L 3-Pole Handle Tie (10 Pack) TEYXHT3K
TEYD/TEYH/TEYL Padlocking
Padlock Device TEYXPLD1
1Right hand mounting only.
2Right or left hand mounting.
3Only available in 3-pole circuit breaker.

TEYD/TEYH/TEYL Reference Publications


Installation Instructions DEH-41590
Mounting Base Installation Instructions DEH-41556
1-Pole Circuit Breaker Outline Drawing 10106028SH1
3-Pole Circuit Breaker Outline Drawing 10106029SH1
2-Pole Circuit Breaker Outline Drawing 10106030SH1
TEY3B125 Mounting Base Outline Drawing 10110291SH1

6-34 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Molded Case Circuit Breakers Section 6
Industrial Circuit Breakers
10-150A Circuit Breakers
Thermal-Magnetic Trip
E150 Line Circuit Breakers
Types TEB, TED, THED
Noninterchangeable Trip

Product Number Structure

TEB 1 1 1 015 WL

Family/Interruption Frame Rating Voltage Ampere


Rating (Amperes) Poles Rating Rating Lugs
TEB = Core E / Low Tier 1 = 150 1 = 1 pole 1 = 120V 010 to 150 (blank) = Load Lugs
TED = Core E / Mid Tier 2 = 2 poles 2 = 240V WL = Line & Load
THED =Core E / High Tier 3 = 3 poles 3 = 277V
4 = 480V
Interruption Ratings shown on page 6-7
Note: This information is provided for interpreting product numbers 6 = 600V
(it should not be used to build product numbers).

Single Pole Includes Cu/Al load lugs only. If line lugs are required, add suffix WL to Product Number.
Type TEB Type TED Type THED
120 Vac 125 Vdc 277 Vac 125 Vdc 347 Vac1 277 Vac 347 Vac1
Ampere
Rating Product Number Product Number Product Number Product Number Product Number
10 TEB1110102,4 TED1130102,4
15 TEB1110153,4 TED1130153,4 TED1140153,4 THED1130154 THED1140153,4
20 TEB1110203,4 TED1130203,4 TED1140203,4 THED1130204 THED1140203,4
25 TEB1110254 TED1130254 TED1140254 THED1130254 THED1140254
30 TEB1110304 TED1130304 TED1140304 THED1130304 THED1140304
35 TEB1110354 TED1130354
40 TEB1110404 TED1130404
45 TEB1110454 TED1130454
50 TEB1110504 TED1130504
60 TEB111060 TED113060
70 TEB111070 TED113070
80 TEB111080 TED113080
90 TEB111090 TED113090
100 TEB111100 TED113100

Two Pole Includes Cu/Al line and load lugs. For optional lugs, see page 6-103 and 6-105.
Type TEB Type TED Type THED, Hi-Break 5
240 Vac, 250 Vdc 480 Vac, 250 Vdc 480 Vac, 250 Vdc
Ampere
Rating Product Number Product Number Product Number
10 TEB122010WL2,4 TED124010WL2,4
15 TEB122015WL4 TED124015WL4 THED124015WL4
20 TEB122020WL4 TED124020WL4 THED124020WL4
25 TEB122025WL4 TED124025WL4 THED124025WL4
30 TEB122030WL4 TED124030WL4 THED124030WL4
35 TEB122035WL4 TED124035WL4 THED124035WL4
40 TEB122040WL4 TED124040WL4 THED124040WL4
45 TEB122045WL4 TED124045WL4 THED124045WL4
50 TEB122050WL4 TED124050WL4 THED124050WL4
60 TEB122060WL TED124060WL THED124060WL
70 TEB122070WL TED124070WL THED124070WL
80 TEB122080WL TED124080WL THED124080WL
90 TEB122090WL TED124090WL THED124090WL
100 TEB122100WL TED124100WL THED124100WL
110 TED124110WL
125 TED124125WL
150 TED124150WL
1Suitable for 10 kAIC at 480 Vac, but not labeled or UL listed.
2Not UL listed, rated 5kA @ 120V, 240V and 480V.
3Single-pole, 15-and 20-ampere breakers are also UL listed as switching duty breakers, suitable for switching 120 Vac (TEB), 277, 347 Vac (TED, THED) fluorescent lighting loads.
4UL listed for HID (high intensity discharge).
5Two-pole breaker is furnished in three-pole case.

Notes: All TEB, TED, THED breakers UL listed as HACR type except 10 ampere.
All TEB, TED, THED breakers suitable for reverse feed.
60/75C rating through 100 amperes, 75C rating above 100 amperes.

Rev. 11/13 www.geindustrial.com BuyLog Catalog 6-35


Data subject to change
without notice
Molded Case Circuit Breakers Section 6
Industrial Circuit Breakers
10-150A Circuit Breakers
Thermal-Magnetic Trip
E150 Line Circuit Breakers
Types TEB, TED, THED
Noninterchangeable Trip

Three Pole Includes Cu/Al line and load lugs. For optional lugs, see page 6-103 and 6-105.
Type TEB Type TED Type THED, Hi-Break
240 Vac 480 Vac 600 Vac 600 Vac
Ampere
Rating Product Number Product Number Product Number Product Number
10 TEB132010WL1,3 TED134010WL1,3
15 TEB132015WL3 TED134015WL3
20 TEB132020WL3 TED134020WL3 TED136020WL3 THED136020WL3
25 TEB132025WL3 TED134025WL3 TED136025WL3 THED136025WL3
30 TEB132030WL3 TED134030WL3 TED136030WL3 THED136030WL3
35 TEB132035WL3 TED134035WL3 TED136035WL3 THED136035WL3
40 TEB132040WL3 TED134040WL3 TED136040WL3 THED136040WL3
45 TEB132045WL3 TED134045WL3 TED136045WL3 THED136045WL3
50 TEB132050WL3 TED134050WL3 TED136050WL3 THED136050WL3
60 TEB132060WL TED134060WL TED136060WL
70 TEB132070WL TED134070WL TED136070WL THED136070WL
80 TEB132080WL TED134080WL TED136080WL
90 TEB132090WL TED134090WL TED136090WL THED136090WL
100 TEB132100WL TED134100WL TED136100WL THED136100WL
110 TED134110WL TED136110WL THED136110WL
125 TED134125WL TED136125WL THED136125WL
150 TED134150WL TED136150WL THED136150WL
100NA TED134YT1002 TED136YT1002
150NA TED134YT1502 TED136YT1502
1Not UL listed, rated 5kA @ 120V, 240V and 480V.
2Includes factory-installed dummy trip.
3UL listed for HID (high intensity discharge).

Notes: All TEB, TED, THED breakers UL listed as HACR type except 10 ampere.
All TEB, TED, THED breakers suitable for reverse feed.
60/75C rating through 100 amperes, 75C rating above 100 amperes.

Accessories: See pages 6-39 to 6-44 and 6-94 to 6-106.

Add-on Current Limiter UL Listed


100 kAIC at 480 and 600 VAC4
Ampere
Rating Product Number
15 TEDL36015
20 TEDL36020
30 and 60 TEDL36060
100 TEDL36100
4For use with 3 Pole TED/THED only

E150 Reference Publications


TDR Operating Mechanism GEH-2994
Shunt Trip GEH-3416
Undervoltage Release GEH-3417
Auxiliary Switch GEH-3418
Three Coil Shunt Trip GEH-3434
Mechanical Interlock GEH-4310
TDM Operating Mechanism GEH-4335
Bell Alarm GEH-4576
Plug-in Mounting Base GEH-4610
STDA Flange Handle GEH-5314
STDA Operating Mechanism GEH-5684
Cable Operator Mechanism GEH-6290
Motor Operator GEH-6500
Back Connected Studs GEJ-3609
Padlocking Device - Standard GEJ-5143
E150 Outline Drawing 139C3643SH1, 2, 4

6-36 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Molded Case Circuit Breakers Section 6
Industrial Circuit Breakers
200-600A Circuit Breakers
Thermal-Magnetic Trip
J600 Line Circuit Breakers
Types TJJ, TJK, THJK

Product Number Structure


TJJ 4 2 6 D 200 WL

Family/Interruption Frame Rating Poles Voltage (blank) = AC Rated Ampere Lugs


Rating (480V) (Amperes) 2 = 2 poles Rating D = THJK Hi-Break Rating (blank) = Load Lugs
TJJ = Core J / 30kA 4 = 400 3 = 3 poles 6 = 600V DC Rated 200 to 600 WL = Line & Load
TJK = Core J / 30kA 6 = 600 40kA @ 250V LL = Less Lugs
THJK = Core J / 35kA 50kA @ 500V
25kA @ 600V
Note: This information is provided for interpreting product numbers
(it should not be used to build product numbers).

Type TJJ Noninterchangeable Trip, includes Cu/Al Line and Load Lugs, suitable for reverse feed
Frame
2-Pole, 400 Ampere Frame 3-Pole, 400 Ampere Frame Terminal Lugs for Front
Adjustable Instantaneous 600 Vac, 250 Vdc 600 Vac Connection (Cu/Al)
Trip Ampere Range
Ampere Product Product Copper/ Wire
Rating Low High Number Number Aluminum Lugs Size
200 600 2000 TJJ426200WL TJJ436200WL
225 675 2250 TJJ426225WL TJJ436225WL TCAL433
(1) 6-600
250 750 2500 TJJ426250WL TJJ436250WL Included in
or
300 900 3000 TJJ426300WL TJJ436300WL price of
(2) 2/0-250 Cu/Al
350 1050 3500 TJJ426350WL TJJ436350WL breaker
400 1200 4000 TJJ426400WL TJJ436400WL

Types TJK, THJK Interchangeable Trip, includes Cu/Al Line and Load Lugs, not suitable for reverse feed
Complete Circuit Breaker Terminal Lugs for Front
Includes Line and Load Lugs Connection (Cu/Al)1
Adjustable Instantaneous
Trip Ampere Frame Only Trip Unit Only. Use Product Number
Ampere Range Standard Hi-Break Product with Standard and (Order 2
Rating Low High Product Number Product Number Number Hi-Break Frames per pole) Wire Size
400A FrameTwo-Pole
200 600 2000 TJK426200WL THJK426200WL TJK426F000 TJK426T200
225 675 2250 TJK426225WL THJK426225WL Standard Frame TJK426T225
(1) 6-600
250 750 2500 TJK426250WL THJK426250WL TJK426T250
TCAL433 or
300 900 3000 TJK426300WL THJK426300WL THJK426F000 TJK426T300
(2) 2/0-250 Cu/Al
350 1050 3500 TJK426350WL THJK426350WL Hi-Break TJK426T350
400 1200 4000 TJK426400WL THJK426400WL TJK426T400

400A FrameThree-Pole
200 600 2000 TJK436200WL THJK436200WL TJK436F000 TJK436T200
225 675 2250 TJK436225WL THJK436225WL Standard Frame TJK436T225
250 750 2500 TJK436250WL THJK436250WL TJK436T250
300 900 3000 TJK436300WL THJK436300WL TJK436T300 (1) 6-600
350 1050 3500 TJK436350WL THJK436350WL THJK436F000 TJK436T350 TCAL433 or
400 1200 4000 TJK436400WL THJK436400WL Hi-Break TJK436T400 (2) 2/0-250 Cu/Al
400 600 2000 TJK436TM14002
Mag 1200 4000 TJK436TM24002
Only 350 1000 TJK436TM34002
1For optional lugs, see page 6-103.
2Not UL listed.
3Alternate lug for 750 kcmil Cu/Al cable, Product Number TCAL47.

Accessories: See pages 6-39 to 6-44 and 6-94 to 6-106.

Rev. 11/13 www.geindustrial.com BuyLog Catalog 6-37


Data subject to change
without notice
Molded Case Circuit Breakers Section 6
Industrial Circuit Breakers
200-600A Circuit Breakers
Thermal-Magnetic Trip
J600 Line Circuit Breakers
Types TJJ, TJK, THJK

Type THJK - 600V High Break DC Circuit Breakers


Adjustable Instantaneous
Trip Ampere Frame Only Trip Unit Only. Use Product Number
Ampere Range Hi-Break Product w/ Standard and (Order 2
Rating Low High Product Number Number Hi-Break Frames per pole) Wire Size
400A Frame Three-Pole
200 600 2000 THJK436D200WL TJK436T200
225 675 2250 THJK436D225WL TJK436T225
(1) 6-600
250 750 2500 THJK436D250WL TJK436T250
THJK436D000 TCAL433 or
300 900 3000 THJK436D300WL TJK436T300
(2) 2/0-250 Cu/Al
350 1050 3500 THJK436D350WL TJK436T350
400 1200 4000 THJK436D400WL TJK436T400

600A Frame Three-Pole


250 750 2500 THJK636D250WL TJK636T250
(1) 6-600
300 900 3000 THJK636D300WL TJK636T300
THJK636D000 TCAL433 or
350 1050 3500 THJK636D350WL TJK636T350
(2) 2/0-250 Cu/Al
400 1200 4000 THJK636D400WL TJK636T400

Types TJK, THJK Interchangeable Trip, includes Cu/Al Line and Load Lugs, not suitable for reverse feed
Complete Circuit Breaker Terminal Lugs for Front
Includes Line and Load Lugs Connection (Cu/Al)1
Adjustable Instantaneous
Trip Ampere Frame Only Trip Unit Only. Use Product Number
Ampere Range Standard Hi-Break Product w/ Standard and (Order 2
Rating Low High Product Number Product Number Number Hi-Break Frames per pole) Wire Size
600A FrameTwo-Pole
250 750 2500 TJK626250WL THJK626250WL TJK626F000 TJK626T250 TCAL432 (1)
(1) 6-600
6-600
300 900 3000 TJK626300WL THJK626300WL TJK626F000
Standard TJK626T300 TCAL432 or
or
350 1050 3500 TJK626350WL THJK626350WL Standard
Frame TJK626T350 (2)
(2) 2/0-250 Cu/Al
2/0-250 Cu/Al
400 1200 4000 TJK626400WL THJK626400WL Frame
THJK626F000 TJK626T400
450 1350 4500 TJK626450WL THJK626450WL THJK626F000
Hi-Break TJK626T450 (2) 4/0-350
(2) 4/0-350 Cu
Cu
500 1500 5000 TJK626500WL THJK626500WL Hi-Break TJK626T500 TCAL63
TCAL63 or
Frame or
600 1800 6000 TJK626600WL THJK626600WL TJK626T600 (2) 300-500
(2) 300-500 Al
Al

600A FrameThree-Pole
250 750 2500 TJK636250WL THJK636250WL TJK636T250 (1)
(1) 6-600
6-600
300 900 3000 TJK636300WL THJK636300WL TJK636F000 TJK636T300 or
TJK636F000 TCAL432 or
350 1050 3500 TJK636350WL THJK636350WL Standard TJK636T350 (2) 2/0-250
2/0-250 Cu/Al
Standard (2) Cu/Al
400 1200 4000 TJK636400WL THJK636400WL Frame TJK636T400
450 1350 4500 TJK636450WL THJK636450WL Frame
THJK636F000 TJK636T450
500 1500 5000 TJK636500WL THJK636500WL THJK636F000
Hi-Break TJK636T500 TCAL63 (2) 4/0-350 Cu
Hi-Break (2) 4/0-350
or Cu
600 1800 600 TJK636600WL THJK636600WL Frame TJK636T600 TCAL63
Frame or
(2) 300-500 Al
600 6000 2000 TJK636TM16003
(2) 300-500 Al
Mag
1800 6000 TJK636TM26003
Only
1For optional lugs, see page 6-103.
2Alternate lug for 750 kcmil Cu/Al cable, Product Number TCAL47
3Not UL listed.

Accessories: See pages 6-39 to 6-44 and 6-94 to 6-106.

J600 Reference Publications


Mechanical Interlock GEH-3033
Trip Unit GEH-3035
Bell Alarm GEH-3320
Auxiliary Switch GEH-3321
Three Coil Shunt Trip GEH-3346
Shunt Trip GEH-3435
TDR Operating Mechanism GEH-3450
Plug-in Mounting Base GEH-4342
Motor Operator GEH-4676
TDM Operating Mechanism GEH-5023
STDA Flange Handle GEH-5314
STDA Operating Mechanism GEH-5318
Undervoltage Release GEH-5407
J600 Outline Drawing 455C564SH1

6-38 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Molded Case Circuit Breakers Section 6
Internal Accessories
Molded Case Circuit Breakers

Accessory Devices and Ratings


Internally mounted accessories can be either factory or field
installed, but should be factory installed when UL listing is Pole Positions
required. LLeft
CCenter
Factory installed devices with leads exiting from the side are UL RRight
listed, but when leads exit from the back the UL listing is void.
Lead Wire Exit
For accessory installation combinations refer to table below. SSide
Mounting Pole refers to left-, center- or right-hand pole as seen BBack
when facing the front of the breaker. Control leads may exit the
breaker from its side (S) or back (B) 1.
Nonautomatic circuit breakers (molded case switches) require
dummy trip units if internal accessories are to be field installed
(refer to page 6-44).
J Frame Circuit Breaker with Internal
Accessories Mounted in Each Pole

Auxiliary Switch3 Undervoltage Three Coil


Bell Alarm Switch or Shunt Trip Release Shunt Trip

Mounting Pole Inst. Mounting Pole Inst. Mounting Pole Inst. Mounting Pole Inst. Total Number of
Sheet Sheet Sheet Sheet Accessories Within any
Breaker Type L C R GEH- L R GEH- L R GEH- L R GEH- One Circuit Breaker

TQB, THQB,
One accessory only. Mounts
THHQB, TXQB,
4 in a one-inch frame and
TQL, THQL, UL
increase overall breaker size
THHQL, TXQL,
by one pole. May be applied
TQC, THQC,
to 1-, 2-, or 3-pole breakers.
THHQC, TXQC
4
TQD, THQD UL One accessory only
E150 TEB,
TEC, TED, 3418 2-pole circuit breakerany
Aux one 3-pole circuit breaker
THED, UL7 UL 4576 UL 7 UL UL 3417 UL 8 3434
THLC1, 3416 any two except UVR and
S.T. 3-coil shunt trip
TB15,6,8
F225 9
TFC, TFJ, TFK,
THFK, THLC2, UL 4620 UL UL 4653 UL UL 4653 UL8 UL 4622 any two
THLC4, TLB2,
TLB4
J600 TJC, 3321
TJD, TJJ, Any two plus bell alarm except
Aux
TJK, THJK,
UL 8 3320 UL UL
3435
UL 5407 UL8 3346 TB4, TBC4 any one plus bell
alarm .
TB45, TBC45 S.T.
K1200 TKC, 3321
TKM, THKM Aux
UL 8 4305 UL UL UL 5408 UL8 3346 Any two plus bell alarm
TB65, TBC65 3344
TB8, TBC8 S.T.

Red Red
White Brown/white
Brown/white
Accessory-Lead Auxiliary Switch Blue All accessory contacts shown
with the circuit breaker in
Color Coding10 White tripped position.
Purple
Black Blue
Yellow Yellow
Brown Black Blue Black
Bell Alarm Switch Shunt Trip Undervoltage Release Three-Coil Shunt Trip
1 Except TFC and TFJ, F225 line model 4 frames and trips (mfg. code date J101+ (1981 or later), and THLC2, THLC4, TLB4 are UL listed for
field installation of most accessories.
2 Not UL listed.
3 600 Vac auxiliary switches are not UL listed.
4 Accessories are factory installed only.
5 UL listed at 200 AIC without internal accessories, 100 AIC with internally mounted accessories.
6 Accessories not available for single-pole TEB/TED frame. Use two-pole circuit breaker.
7 Left pole mounting available for two-pole THED but not for two-pole TEB, TED.
8 Not available with lead exit from the back of breaker.
9 UL listed interrupting capacity with accessories: 10 kAIC at 600 Vac, 22 kAIC at 480 Vac, 22 kAIC at 240 Vac.
10Leads are #18 125C Vulkene insulated.

Rev. 11/13 www.geindustrial.com BuyLog Catalog 6-39


Data subject to change
without notice
Molded Case Circuit Breakers Section 6
Internal Accessories
Internally Mounted Signaling and Controlling Functions

Auxiliary Switches
Unless otherwise noted switch is SPDT rated 6 amperes at rated ac voltage, 1/2 amperes at 125 Vdc, 1/4 amperes at 250 Vdc.
Control Voltage 240 Vac, 250 Vdc Maximum Control Voltage 600 Vac, 250 Vdc Maximum
UL Listed When Factory Installed Suffix1 Not UL Listed Suffix1
Number of Add to Base Product Add to Base Product
SPDT Switch Base Number for Factory Base Number for Factory
Breaker Type Elements Number Installation4 Number Installation4
TEB, TEC, TB1 1 TEDAS2AB1R,L2,3 S TEDAS6AB1R,L2,3 S
TED, THED,THLC13 2 TEDAS2AB2R,L2,3 S TEDAS6AB2R,L2,3 S
1 TJKASA2AB1R,L S TJKASA6AB1R,L S
2 TJKASA2AB2R,L S TJKASA6AB2R,L S
TJC, TJD, TJJ, TJK, THJK
3 TJKASA2AB3R,L S TJKASA6AB3R,L S
4 TJKASA2AB4R,L S TJKASA6AB4R,L S
1 TB4ASA2AB1R,L S TB4ASA6AB1R,L S
2 TB4ASA2AB2R,L S TB4ASA6AB2R,L S
TB4, TBC4
3 TB4ASA2AB3R,L S TB4ASA6AB3R,L S
4 TB4ASA2AB4R,L S TB4ASA6AB4R,L S
1 TKMAAS2AB1 RS or LS TKMAAS6AB1 RS or LS
TKM, THKM, TKC, TB6, 2 TKMAAS2AB2 RS or LS TKMAAS6AB2 RS or LS
TB8, TBC6, TBC8 3 TKMAAS2AB3 RS or LS TKMAAS6AB3 RS or LS
4 TKMAAS2AB4 RS or LS TKMAAS6AB4 RS or LS
1"S" suffix for wires out the side of breaker. For lead exit from back of breaker, replace suffix "S" with "B" and multiply list price by 1.25. "B" suffix not UL listed. Not available
with leads out the back for "Q-Line", or 2 element auxiliary switches used on TFG, TFJ, TFK, THFK, THLC2, THLC4, TLB2, and TLB4.
2Auxiliary switch mounts in right pole only on two-pole TEB, TED breakers. (Factory installed only.)
3Not available with B suffixleads out back.
4For factory installation, contact Customer Service Center.

6-40 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Molded Case Circuit Breakers Section 6
Internal Accessories
Internally Mounted Signaling and Controlling Functions

How to Order
For field replacement, order base number only. For factory installation, contact Customer
Service Center and order base number plus appropriate suffix. For a nonautomatic breaker
(molded case switch) a dummy trip is required when installing either a shunt trip or UVR.
Shunt Trip
Remote Tripping Trips breaker by remote control. Trip coil de-energized when breaker
opens. Device meets UL requirements for service to ground fault system.
Undervoltage Release
Undervoltage release automatically trips breaker when applied coil voltage drops to
30 to 70 percent of rated value. Time-delay unit prevent nuisance tripping due to
momentary loss of voltage. Separate externally mounted unit has 120 Vac input and
125 Vdc output. Used in conjunction with 125 Vdc undervoltage release which must be
ordered separately. Product number SPUVTD for adjustable delay .1 to 1.0 seconds.

Shunt Trip
Product Number1,2 UL Listed When Factory Installed
Suffix Number3
Accessory Voltage Base Number Add to Base Product Number
Breaker Type Vac Vdc for Field Replacement for Factory Installation
120-240 TQSTA14,5,6,7 10
TQB, THQB, THHQB, TXQB,
12 TQSTA74,6,7 10
TQL, THQL, THHQL, TXQL
24-48 TQSTA84,6,7 10
120 TQDST18,9 10
240 TQDST29 10
TQD, THQD
12 TQDST79 10
24 TQDST89 10
120 TEDST12 RS
240 TEDST12 RS
480 TEDST13 RS
600 TEDST13 RS
TEB, TEC, TB1-B11,
12 TEDST7 RS
TED, THED, THLC1
24 TEDST8 RS
48 TEDST9 RS
125 TEDST12 RS
250 TEDST11 RS
120 TFKSTA121 RS or LS
240 TFKSTA121 RS or LS
480 TFKSTA131 RS or LS
600 TFKSTA131 RS or LS
TFC, TFJ, TFK, THFK, THLC2,
12 TFKSTA71 RS or LS
THLC4, TLB2, TLB4
24 TFKSTA81 RS or LS
48 TFKSTA91 RS or LS
125 TFKSTA121 RS or LS
250 TFKSTA111 RS or LS
1UL listed for field installation on TFC, TFJ, TFK, and THFK model 4 frames and trips (mfg. Code date J101 or later) and on THLC2, THLC4, TLB4.
2For replacement voltage suppressor on 120 Vac UVRs for F225 line, order Product Number 286A8062G1. for 120 Vac UVRs on all other breaker lines, order Product Number
192A8300G1.
3"S" suffix for wires out the side of the breaker. For lead exit from back of breaker, replace suffix "S" with "B", and multiply "S" accessory List Price by 1.25. "B" suffix not UL listed.
Not available with leads out the back on "Q-Line." For factory installation, contact Customer Service Center.
4Mounts on a one-inch frame and increases overall breaker size by one pole added to left side. May be applied to 1-, 2-, or 3-pole breakers. Maximum total breaker width is
4-pole. Must be factory installed.
5A selective listing of breaker product numbers that include 120 Volt ac shunt trip appears on page 6-22.
6Not available on GFCI (5 ma) or Equipment Ground Fault (30 ma) breakers.
7TQST shunt trips not available on breakers over 100 A.
8Not available with B suffixleads out back.
9Must be factory installed, right pole only.
10To order, specify both the accessory and breaker product number =, e.g. THQL2130, TQST1 identifies a 30 A, 2-pole plug-in breaker with a factory installed 120 Vac
shunt trip.
11For TB1 with bolt-on limiters.

Rev. 11/13 www.geindustrial.com BuyLog Catalog 6-41


Data subject to change
without notice
Molded Case Circuit Breakers Section 6
Internal Accessories
Internally Mounted Signaling and Controlling Functions

Shunt Trip (continued)


Product Number UL Listed When Factory Installed
Suffix Number1
Accessory Voltage Base Number Add to Base Product Number
Breaker Type Vac Vdc for Field Replacement for Factory Installation
120 TJKSTA12R,L S
240 TJKSTA12R,L S
480 TJKSTA13R,L S
600 TJKSTA13R,L S
TJC, TJD, TJJ, TJK, THJK 12 TJKSTA7R,L S
24 TJKSTA8R,L S
48 TJKSTA9R,L S
125 TJKSTA12R,L S
250 TJKSTA11R,L S
120 TB4STA12R,L3
240 TB4STA12R,L3
480 TB4STA13R,L3
600 TB4STA13R,L3
TB4, TBC4 12 TB4STA7R,L3
24 TB4STA8R,L3
48 TB4STA9R,L3
125 TB4STA12R,L3
250 TB4STA11R,L3
120 TKMASTA12R,L S
240 TKMASTA12R,L S
480 TKMASTA13R,L S
600 TKMASTA13R,L S
TKC, TKM, THKM, TB6,
12 TKMASTA7R,L S
TB8, TBC6, TBC82
24 TKMASTA8R,L S
48 TKMASTA9R,L S
125 TKMASTA12R,L S
250 TKMASTA11R,L S
1"S" suffix for wires out the side of the breaker. For lead exit from back of breaker, replace suffix "S" with "B". "B" suffix not UL listed. Not available with leads out the
back on "Q-Line." For factory installation, contact Customer Service Center.
2Not UL listed.
3Not available for factory installation.

6-42 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Molded Case Circuit Breakers Section 6
Internal Accessories
Internally Mounted Signaling and Controlling Functions

Undervoltage Release
Product Number1,2 UL Listed When Factory Installed
Suffix Number3
Accessory Voltage Base Number Add to Base Product Number
Breaker Type Vac Vdc for Field Replacement for Factory Installation
120 TEDUV1 RS
240 TEDUV2 RS
480 TEDUV4 RS
600 TEDUV6 RS
TEB, TEC, TB1-B4
12 TEDUV7 RS
TED, THED, THLC1
24 TEDUV8 RS
48 TEDUV9 RS
125 TEDUV10 RS
250 TEDUV11 RS
120 TJUV1R S
240 TJUV2R S
480 TJUV4R S
600 TJUV6R S
TJC, TJD, TJJ, TJK, THJK 12 TJUV7R S
24 TJUV8R S
48 TJUV9R S
125 TJUV10R S
250 TJUV11R S
120 TKUV1R S
240 TKUV2R S
480 TKUV4R S
600 TKUV6R S
TKC, TKM, THKM, TB6,
12 TKUV7R S
TB8, TBC6, TBC85
24 TKUV8R S
48 TKUV9R S
125 TKUV10R S
250 TKUV11R S
1UL listed for field installation on TFC, TFJ, TFK, and THFK model 4 frames and trips (mfg. Code date J101 or later) and on THLC2, THLC4, TLB4.
2For replacement voltage suppressor on 120 Vac UVRs for F225 line, order Product Number 286A8062G1 for 120 Vac UVRs on all other breaker lines, order
Product Number 192A8300G1.
3"S" suffix for wires out the side of the breaker. For lead exit from back of breaker, replace suffix "S" with "B". "B" suffix not UL listed. For factory installation, contact
Customer Service Center.
4For TB1 with bolt-on limiters.
5Not UL listed.

Rev. 11/13 www.geindustrial.com BuyLog Catalog 6-43


Data subject to change
without notice
Molded Case Circuit Breakers Section 6
Internal Accessories
Internally Mounted Signaling and Controlling Functions

Bell Alarm Switches


Product Number2
Breaker UL Listed When Factory Installed
Type Base No. Suffix
TEB, TEC, TB1 TEDBAR or
S
TED, THED, THLC1 TEDBAL3,4
TFC, TFJ, TFK, THFK,
TFKBAAR5,6 S
THLC2, THLC4, TLB4
TJC, TJJ, TJK, THJK
TJKBAAL7 S
TB4, TBC4, TJD
TKC, TKM, THKM,
TKMABAAL7 S
TB6, TBC6, TBC8, TB8

Blown Fuse Detector-Three-Coil Shunt Trip


Product Number2
Breaker UL Listed When Factory Installed
Type Base No. Suffix
TED, THED, TEC3 TEDST316 RS
TJJ, TJK, THJK, TJD, TJC TJKST316 LS

Dummy Trip1
Breaker Type Product Number
E150 Internal accessories for these noninterchangeable
FJ225 breakers require factory-installed dummy trips.
JJ400 Automatically supplied when accessories are ordered.
JK400 TJKYT3 (two-pole, three-pole)
JK600 TJKYT36 (two-pole, three-pole)
KM800 TKMAYT3 (two-pole, three-pole)
1Not UL listed when field installed.
2Add "B" suffix for leads exit from back of breaker. For factory installation, contact
Customer Service Center.
3Not available with B suffix leads out back.
4Not available for two-pole TEB, TED. Order TEDBAR.
5Changes circuit breaker interrupting capacity to: 10kA @ 600 Vac, 22kA @ 480 Vac,
22kA @ 240 Vac, for TFC, TFJ, TFK and THFK only.
6UL listed for field installation.
7Mounts in center pole with leads out left side.

6-44 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Molded Case Circuit Breakers Section 6
Spectra RMS
SE150 Frame
15-150A Circuit Breakers
Electronic Trip
Suitable for Reverse Feed
UL File E-11592, CSA LR 40350

Product Number Structure

S E D A 2 4 A T 0030

Frame Rating Interruption Continuous Voltage Trip Trip Sensor


Family (Amperes) Rating (480V) Load Rating Poles Rating Unit Function (Max Amps)
S = Spectra E = 150 D = 18 kA A = Standard 2 = 2 poles 4 = 480V A = RMS1 T = LSI1 0030
H = 25 kA 3 = 3 poles 6 = 600V 0060
L = 65 kA 0100
P = 100 kA 0150

1Adjustable Instantaneous with Tracking Short Time (Long Time established via Interchangeable Rating Plugs).
Note: This information is provided for interpreting product numbers (it should not be used to build product numbers).

SED, SEH, SEL, SEP2; 2-Pole, 150A, 480 Vac Max., (IEC 947-2: 160A, 415 Vac Max.)
Terminal Lugs for
Rating Plug Frame Front Connection (Cu/Al)
UL 489 IC @ 480 Vac
Adjustable Instantaneous 18kA 25kA 65kA 100kA
Ampere Trip Range Amps Product Current Product Product Product Product Product Wire
Rating Low High Number Sensor Number Number Number Number Number Range
15 43 182 SRPE30A15
20 58 254 SRPE30A20 30 SEDA24AT00303 SEHA24AT00303 SELA24AT00303 SEPA24AT00303
25 73 332 SRPE30A25
30 87 415 SRPE30A30
35 104 453 SRPE60A35
40 118 501 SRPE60A40
45 134 583 SRPE60A45 60 SEDA24AT00603 SEHA24AT00603 SELA24AT00603 SEPA24AT00603 12-3/0 Cu
50 148 637 SRPE60A50 TCAL18
12-3/0 Al
60 178 777 SRPE60A60
70 206 863 SRPE100A70
80 236 999 SRPE100A80 100 SEDA24AT0100 SEHA24AT0100 SELA24AT0100 SEPA24AT0100
90 267 1138 SRPE100A90
100 297 1280 SRPE100A100
110 328 1426 SRPE150A110
125 374 1640 SRPE150A125 150 SEDA24AT0150 SEHA24AT0150 SELA24AT0150 SEPA24AT0150
150 450 1991 SRPE150A150

SED, SEH, SEL, SEP2; 3-Pole, UL/CSA: 150A, 600 Vac Max., (IEC 947-2: 160A, 690 Vac Max.)
Terminal Lugs for
Rating Plug Frame Front Connection (Cu/Al)
UL 489 IC @ 480 Vac
Adjustable Instantaneous 18kA 25kA 65kA 100kA
Ampere Trip Range Amps Product Current Product Product Product Product Product Wire
Rating Low High Number Sensor Number Number Number Number Number Range
15 43 182 SRPE30A15
20 58 254 SRPE30A20 30 SEDA36AT00303 SEHA36AT00303 SELA36AT00303 SEPA36AT00303
25 73 332 SRPE30A25
30 87 415 SRPE30A30
35 104 453 SRPE60A35
40 118 501 SRPE60A40
45 134 583 SRPE60A45 60 SEDA36AT00603 SEHA36AT00603 SELA36AT00603 SEPA36AT00603
50 148 637 SRPE60A50 12-3/0 Cu
TCAL18
60 178 777 SRPE60A60 12-3/0 Al
70 206 863 SRPE100A70
80 236 999 SRPE100A80 100 SEDA36AT0100 SEHA36AT0100 SELA36AT0100 SEPA36AT0100
90 267 1138 SRPE100A90
100 297 1280 SRPE100A100
110 328 1426 SRPE150A110
125 374 1640 SRPE150A125 150 SEDA36AT0150 SEHA36AT0150 SELA36AT0150 SEPA36AT0150
150 450 1991 SRPE150A150
2SEL, SEP UL current limiting.
3When used with 15-50A Rating Plug, UL listed for HID (high intensity discharge).

Note: All Spectra breakers UL listed as HACR type.


All Spectra breakers marked CE.

Rev. 11/13 www.geindustrial.com BuyLog Catalog 6-45


Data subject to change
without notice
Molded Case Circuit Breakers Section 6
Spectra RMS
SE150 Frame
15-150A Circuit Breakers
Electronic Trip
Suitable for Reverse Feed
UL File E-11592, CSA LR 40350

SE150 Add-on 3-Pole Limiters Reference Publications


Maximum Product kAIC Use With Breaker/
Available for download from www.geindustrial.com/publibrary
Ampere Rating Number @600 Vac MCP Frame
SE Breaker
150 SAXSEL36150 65 SEL
Installation Instructions GEH-5591
150 SAXSEP36150 100 SEP
Rating Plug GEH-5549
SE Breaker Accessories
Bell Alarm & Aux. Switch GEH-5593
Shunt Trip & UVR GEH-5551
Padlock Device GEJ-3056
Lug Kits GEJ-3051
Control Wire Lug Kit GEH-5881
Add-On Limiters DEH-4671
STDA Flange Handle GEH-5314
STDA Operating Mechanism GEH-5684
TDR Operating Mechanism GEH-5609
TDM Operating Mechanism GEH-5611
Motor Operator GEH-5613
Cable Operator Mechanism GEH-6290
Operator Adapter Kits GEH-5688
Mechanical Interlock GEH-5615
Warning Labels GEH-5686
SE Mounting Provisions
Plug-in Mounting Base GEH-4610
Back Connected Studs GEJ-3609
Outline Drawing 168D1109SH1
Series Ratings DET-008
Spectra RMS Circuit Breakers in Combination with
Cooper Bussman Distribution Block DET-781

6-46 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Molded Case Circuit Breakers Section 6
Spectra RMS
SF250 Frame
70-250A Circuit Breakers
Electronic Trip
Suitable for Reverse Feed
UL File E-11592, CSA LR 40350

Product Number Structure


S F H A 2 4 A T 0250

Frame Rating Interruption Continuous Voltage Trip Trip Sensor


Family (Amperes) Rating (480V) Load Rating Poles Rating Unit Function (Max Amps)
S = Spectra F = 250 H = 35 kA A = Standard 2 = 2 poles 4 = 480V A = RMS1 T = LSI1 0250
L = 65 kA 3 = 3 poles 6 = 600V
P = 100 kA
1Adjustable Instantaneous with Tracking Short Time (Long Time established via Interchangeable Rating Plugs).
Note: This information is provided for interpreting product numbers (it should not be used to build product numbers).

SFH, SFL, SFP2; 2-Pole, UL/CSA: 250A, 480 Vac Max., (IEC 947-2: 250A, 415 Vac Max.)
Terminal Lugs for
Rating Plug Frame Front Connection (Cu/Al)
UL 489 IC @ 480 Vac
Adjustable Instantaneous 35kA 65kA 100kA
Trip Ampere Range
Ampere Product Current Product Product Product Product Wire
Rating Low High Number Sensor Number Number Number Number Range
70 205 700 SRPF250A70
80 235 800 SRPF250A80
90 265 900 SRPF250A90
100 295 1000 SRPF250A100
110 325 1100 SRPF250A110 8-350 Cu
125 370 1250 SRPF250A125 250 SFHA24AT0250 SFLA24AT0250 SFPA24AT0250 TCAL29
150 440 1500 SRPF250A150 8-350 Al
175 515 1750 SRPF250A175
200 590 2000 SRPF250A200
225 665 2250 SRPF250A225
250 736 2500 SRPF250A250

SFH, SFL, SFP2; 3-Pole, UL/CSA: 250A, 600 Vac Max., (IEC 947-2: 250A, 690 Vac Max.)
Terminal Lugs for
Rating Plug Frame Front Connection (Cu/Al)
UL 489 IC @ 480 Vac
Adjustable Instantaneous 35kA 65kA 100kA
Trip Ampere Range
Ampere Product Current Product Product Product Product Wire
Rating Low High Number Sensor Number Number Number Number Range
70 205 700 SRPF250A70
80 235 800 SRPF250A80
90 265 900 SRPF250A90
100 295 1000 SRPF250A100
110 325 1100 SRPF250A110 8-350 Cu
125 370 1250 SRPF250A125 250 SFHA36AT0250 SFLA36AT0250 SFPA36AT0250 TCAL29
150 440 1500 SRPF250A150 8-350 Al
175 515 1750 SRPF250A175
200 590 2000 SRPF250A200
225 665 2250 SRPF250A225
250 736 2500 SRPF250A250
2SFL, SFP UL current limiting.

Note: All Spectra breakers UL listed as HACR type.


All Spectra breakers marked CE.

Rev. 11/13 www.geindustrial.com BuyLog Catalog 6-47


Data subject to change
without notice
Molded Case Circuit Breakers Section 6
Spectra RMS
SF250 Frame
70-250A Circuit Breakers
Electronic Trip
Suitable for Reverse Feed
UL File E-11592, CSA LR 40350

Reference Publications
Available for download from www.geindustrial.com/publibrary
SF Breaker
Installation Instructions GEH-5591
Rating Plug GEH-5549
SF Breaker Accessories
Bell Alarm & Aux. Switch GEH-5593
Shunt Trip & UVR GEH-5551
Padlock Device GEJ-3056
Lug Kits GEJ-3045
Control Wire Lug Kit GEH-5882
STDA Flange Handle GEH-5314
STDA Operating Mechanism GEH-5684
TDR Operating Mechanism GEH-5609
TDM Operating Mechanism GEH-5611
Motor Operator GEH-5613
Cable Operator Mechanism GEH-6290
Operator Adapter Kits GEH-5688
Mechanical Interlock GEH-5615
Mounting Hardware Kits GEH-5659
SF Mounting Provisions
Plug-in Mounting Base GEH-4610
Back Connected Studs GEJ-3635
Outline Drawing 168D1103SH1
Series Ratings DET-008
Spectra RMS Circuit Breakers in Combination with
Cooper Bussman Distribution Block DET-781

6-48 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Molded Case Circuit Breakers Section 6
Spectra RMS
SG600 Frame
125-600A Circuit Breakers
Electronic Trip (Digital, Solid-State)
Suitable for Reverse Feed
UL File E-11592, CSA LR 40350

Product Number Structure


S G D A 2 2 A T 0400

Frame Rating Interruption Continuous Voltage Trip Trip Sensor


Family (Amperes) Rating (480V) Load Rating Poles Rating Unit Function (Max Amps)
S = Spectra G = 600 D = 65 kA1 A = Standard 2 = 2 poles 2 = 240V A = RMS1 T = LSI2 0400
H = 35 kA H = 100% 3 = 3 poles 6 = 600V 0600
L = 65 kA L = 100%
1 SGD rated 65kA at 240V. P = 100 kA P = 100%
2Adjustable Instantaneous with Tracking Short Time (Long Time established via Interchangeable Rating Plugs).
Note: This information is provided for interpreting product numbers (it should not be used to build product numbers).

SGD; 400A, 240 Vac Max., (IEC 947-2: 400A, 690 Vac Max.)
Rating Plug Frame Terminal Lugs for
Front Connection (Cu/Al)
240 Vac
Adjustable Instantaneous 65kA
Trip Ampere Range
Ampere Product Current Product Product4 Wire
Rating Low High Number Sensor Poles Number Number Range
125 380 1275 SRPG400A125 2-pole lug kit
150 455 1530 SRPG400A150 (2) 2/0-500 Cu
175 530 1785 SRPG400A175 2 SGDA22AT04003 TCLK265 or
200 605 2040 SRPG400A200 (1) 8-600 Cu
225 680 2295 SRPG400A225 400
250 755 2550 SRPG400A250 3-pole lug kit
300 905 3060 SRPG400A300 (2) 2/0-500 Al
3 SGDA32AT04003
350 1060 3570 SRPG400A350 TCLK365 or
400 1210 4080 SRPG400A400 (1) 8-600 Al

SGH, SGL, SGP5; 400A, 600 Vac Max., (IEC 947-2: 400A, 690 Vac Max.)
Terminal Lugs for
Rating Plug Frame Front Connection (Cu/Al)
UL 489 IC @ 480 Vac
Adjustable Instantaneous 35kA 65kA 100kA
Trip Ampere Range
Ampere Product Current Product Product Product Product4 Wire
Rating Low High Number Sensor Poles Number Number Number Number Range
125 380 1275 SRPG400A125 2-pole lug kit
150 455 1530 SRPG400A150 (2) 2/0-500 Cu
175 530 1785 SRPG400A175 2 SGHA26AT0400 SGLA26AT0400 SGPA26AT0400 TCLK265 or
200 605 2040 SRPG400A200 (1) 8-600 Cu
225 680 2295 SRPG400A225 400
250 755 2550 SRPG400A250 3-pole lug kit
300 905 3060 SRPG400A300 (2) 2/0-500 Al
3 SGHA36AT0400 SGLA36AT0400 SGPA36AT0400
350 1060 3570 SRPG400A350 TCLK365 or
400 1210 4080 SRPG400A400 (1) 8-600 Al

SGH, SGL5, SGP5; 600A, 600 Vac Max., (IEC 947-2: 630A, 690 Vac Max.)
Terminal Lugs for
Rating Plug Frame Front Connection (Cu/Al)
UL 489 IC @ 480 Vac
Adjustable Instantaneous 35kA 65kA 100kA
Trip Ampere Range
Ampere Product Current Product Product Product Product4 Wire
Rating Low High Number Sensor Poles Number Number Number Number Range
250 765 2530 SRPG600A250 2-pole lug kit
300 915 3035 SRPG600A300 (2) 2/0-500 Cu
2 SGHA26AT0600 SGLA26AT0600 SGPA26AT0600
350 1070 3545 SRPG600A350 TCLK265 or
400 1220 4050 SRPG600A400 600 (1) 8-600 Cu
450 1375 4555 SRPG600A450 3-pole lug kit
500 1525 5060 SRPG600A500 3 SGHA36AT0600 SGLA36AT0600 SGPA36AT0600 (2) 2/0-500 Al
600 1830 6075 SRPG600A600 TCLK365 or (1) 8-600 Al
3Rated 240 Vac max.
4Order one kit for either line or load end; two kits required for both.
5SGL, SGP UL current limiting.

Rev. 11/13 www.geindustrial.com BuyLog Catalog 6-49


Data subject to change
without notice
Molded Case Circuit Breakers Section 6
Spectra RMS
SG600 Frame, 100% Rated
125-600A Circuit Breakers
Electronic Trip (Digital, Solid-State)
Suitable for Reverse Feed
UL File E-11592, CSA LR 40350

Note: All Spectra breakers UL listed as HACR type. All Spectra breakers marked CE.

SGH, SGL2, SGP2; 100% UL Rated, 3-Pole: 400A, 600 Vac Max.; (IEC 947-2: 400A, 690 Vac Max.)
Terminal Lugs for
Rating Plug Frame Front Connection (Cu/Al)
UL 489 IC @ 480 Vac
Adjustable Instantaneous 35kAIC 65kAIC 100kAIC
Trip Ampere Range
Ampere Product Current Product Product Product Product1 Wire
Rating Low High Number Sensor Poles Number Number Number Number Range
125 380 1275 SRPG400A125
150 455 1530 SRPG400A150 (2) 2/0-500 Cu
175 530 1785 SRPG400A175 or
200 605 2040 SRPG400A200 (1) 8-600 Cu
225 680 2295 SRPG400A225 400 3 SGHH36AT0400 SGLL36AT0400 SGPP36AT0400 TCLK365
250 755 2550 SRPG400A250
300 905 3060 SRPG400A300 (2) 2/0-500 Al
350 1060 3570 SRPG400A350 or
400 1210 4080 SRPG400A400 (1) 8-600 Al
1Order one kit for either line or load end; two kits required for both.
2SGL, SGP UL current limiting.

Note: All Spectra breakers UL listed as HACR type.

SGH, SGL2, SGP2; 100% UL Rated, 3-Pole: 600A, 600 Vac Max.; (IEC 947-2: 630A, 690 Vac Max.)
Terminal Lugs for
Rating Plug Frame Front Connection (Cu/Al)
UL 489 IC @ 480 Vac
Adjustable Instantaneous 35kAIC 65kAIC 100kAIC
Trip Ampere Range
Ampere Product Current Product Product Product Product1 Wire
Rating Low High Number Sensor Poles Number Number Number Number Range
250 765 2530 SRPG600A250
300 915 3035 SRPG600A300 (2) 2/0-500 Cu
350 1070 3545 SRPG600A350 or (1) 8-600 Cu
400 1220 4050 SRPG600A400 600 3 SGHH36AT0600 SGLL36AT0600 SGPP36AT0600 TCLK365
450 1375 4555 SRPG600A450 (2) 2/0-500 Al
500 1525 5060 SRPG600A500 (1) 8-600 Al
600 1830 6075 SRPG600A600

6-50 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Molded Case Circuit Breakers Section 6
Spectra RMS
SG600 Frame
125-600A Circuit Breakers
Electronic Trip (Digital, Solid-State)
Suitable for Reverse Feed
UL File E-11592, CSA LR 40350

Reference Publications
Available for download from www.geindustrial.com/publibrary
SG Breaker
Installation Instructions GEH-5663
Rating Plug GEH-5549
MVT & MVT Plus PM Rating Plugs GEH-5887
SG Breaker Accessories
Bell Alarm & Aux. Switch GEH-5593
Shunt Trip & UVR GEH-5551
Lug Kits GEJ-3052
Trip Unit Covers GEH-5664
Door Ring Interlock Catch Kits GEH-5662
STDA Flange Handle GEH-5314
STDA Operating Mechanism GEH-5684
TDR Operating Mechanism GEH-5654
TDM Operating Mechanism GEH-5653
Motor Operator GEH-5657
Cable Operator Mechanism GEH-6290
Cable Operators DEH-40467
Mechanical Interlock GEH-5697
SG Mounting Provisions
Plug-in Mounting Base GEH-5655
Back Connected Studs GEH-5665
Outline Drawing 208C1549SH1, 2, 3
Series Ratings DET-008

Rev. 11/13 www.geindustrial.com BuyLog Catalog 6-51


Data subject to change
without notice
Molded Case Circuit Breakers Section 6
Spectra RMS
SK 1200 Frame
300-1200A Circuit Breakers
Electronic Trip, Digital, Solid-State
Suitable for Reverse Feed
UL File E-11592, CSA LR 40350

Product Number Structure


S K H A 2 6 A T 0800

Frame Rating Interruption Continuous Voltage Trip Trip Sensor


Family (Amperes) Rating (480V) Load Rating Poles Rating Unit Function (Max Amps)
S = Spectra K = 1200 H = 50 kA A = Standard 2 = 2 poles 6 = 600V A = RMS1 T = LSI1 0800
L = 65 kA H = 100% 3 = 3 poles 1200
P = 100 kA L = 100%
P = 100%
1Adjustable Instantaneous with Tracking Short Time (Long Time established via Interchangeable Rating Plugs).
Note: This information is provided for interpreting product numbers (it should not be used to build product numbers).

SKH, SKL, SKP; 800A, 600 Vac Max., (IEC 947-2:800A 690 Vac Max.)
Terminal Lugs for
Rating Plug Frame Front Connection (Cu/Al)
UL 489 IC @ 480 Vac
Adjustable Instantaneous 50kA 65kA 100kA
Trip Ampere Range
Ampere Product Current Product Product Product Product Wire
Rating Low High Number Sensor Poles Number Number Number Number Range
300 940 3015 SRPK800A300
400 1255 4015 SRPK800A400 2 SKHA26AT0800 SKLA26AT0800 SKPA26AT0800 (3) 3/0-500 Cu
500 1570 5020 SRPK800A500 800 TCAL81
600 1875 6195 SRPK800A600
700 2155 7420 SRPK800A700
3 SKHA36AT0800 SKLA36AT0800 SKPA36AT0800 (3) 3/0-500 Al
800 2440 8705 SRPK800A800

SKH, SKL, SKP; 1200A, 600 Vac Max., (IEC 947-2: 1250A, 690 Vac Max.)
Terminal Lugs for
Rating Plug Frame Front Connection (Cu/Al)
UL 489 IC @ 480 Vac
Adjustable Instantaneous 50kA 65kA 100kA
Trip Ampere Range
Ampere Product Current Product Product Product Product Wire
Rating Low High Number Sensor Poles Number Number Number Number Range
600 1825 6110 SRPK1200A600
700 2125 7125 SRPK1200A700 2 SKHA26AT1200 SKLA26AT1200 SKPA26AT1200 (4) 250-500 Cu
800 2430 8145 SRPK1200A800
1200 TCAL125
900 2735 9160 SRPK1200A900
1000 3040 10180 SRPK1200A1000
3 SKHA36AT1200 SKLA36AT1200 SKPA36AT1200 (4) 250-500 Al
1175 3574 11961 SRPK1200A1175
1200 3650 12215 SRPK1200A1200

Note: All Spectra breakers UL listed as HACR type.


All Spectra breakers marked CE.

6-52 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Molded Case Circuit Breakers Section 6
Spectra RMS
SK 1200 Frame, 100% Rated
300-1200A Circuit Breakers
Electronic Trip, Digital, Solid-State
Suitable for Reverse Feed
UL File E-11592, CSA LR 40350

SKH, SKL, SKP; 100% UL Rated, 3-Pole: 800A, 600 Vac Max.; (IEC 947-2: 800A, 690 Vac Max.)
Terminal Lugs for
Rating Plug Frame Front Connection (Cu/Al)
UL 489 IC @ 480 Vac
Adjustable Instantaneous 50kA 65kA 100kA
Trip Ampere Range
Ampere Product Current Product Product Product Product Wire
Rating Low High Number Sensor Poles Number Number Number Number Range
300 940 3015 SRPK800A300
400 1255 4015 SRPK800A400
(3) 3/0-500 Cu
500 1570 5020 SRPK800A500
800 3 SKHH36AT0800 SKLL36AT0800 SKPP36AT0800 TCAL81
600 1875 6195 SRPK800A600
(3) 3/0-500 Al
700 2155 7420 SRPK800A700
800 2440 8705 SRPK800A800

SKH, SKL, SKP; 100% UL Rated, 3-Pole: 1200A, 600 Vac Max.; (IEC 947-2: 100A, 690 Vac Max.)
Terminal Lugs for
Rating Plug Frame Front Connection (Cu/Al)
UL 489 IC @ 480 Vac
Adjustable Instantaneous 50kA 65kA 100kA
Trip Ampere Range
Ampere Product Current Product Product Product Product Wire
Rating Low High Number Sensor Poles Number Number Number Number Range
600 1825 6110 SRPK1200A600
700 2125 7125 SRPK1200A700 3 SKHH36AT1000 SKLL36AT1000 SKPP36AT1000
(4) 250-500 Cu
800 2430 8145 SRPK1200A800
1200 TCAL125
900 2735 9160 SRPK1200A900
(4) 250-500 Al
1000 3040 10180 SRPK1200A1000 3 SKHH36AT12001 SKLL36AT12001 SKPP36AT12001
1200 3650 12215 SRPK1200A1200
1100% UL rated SK1200 supplied with back-
connected assembly which increases breaker
depth. Refer to outline drawings for details.
Lugs not required
Note: All Spectra breakers UL listed as HACR type.
All Spectra breakers marked CE.

Reference Publications
Available for download from www.geindustrial.com/publibrary
SK Breaker
Installation Instructions GEH-5592
Rating Plug GEH-5549
MVT & MVT Plus PM Rating Plugs GEH-5887
SG Breaker Accessories
Bell Alarm & Aux. Switch GEH-5593
Shunt Trip & UVR GEH-5551
Lug Shields for SK1200 GEH-5699
Lug Shields for SKP GEH-5685
Trip Unit Covers GEH-5664
Mounting of Integral Handle GEH-5610
STDA Flange Handle GEH-5314
STDA Operating Mechanism GEH-5684
TDM Operating Mechanism GEH-5612
Coupling TDM Operating Mechanisms GEH-5873
Motor Operator GEH-5614
Cable Operator Mechanism GEH-6291
Handle Extension GEH-5648
Padlocking Device - Standard GEH-5877
Face Mounted Interlock GEH-5698
Mechanical Interlock GEH-5874
SK Mounting Provisions
Plug-in Mounting Base GEH-4342
Back Connected Studs GEJ-3619
Outline Drawing 208C1757SH1
Outline Drawing (1200A 100%) 168D1678SH2
Series Ratings DET-008

Rev. 11/13 www.geindustrial.com BuyLog Catalog 6-53


Data subject to change
without notice
Molded Case Circuit Breakers Section 6
Industrial Circuit Breakers
Spectra RMS Circuit Breakers with
microEntelliGuard Trip Units

microEntelliGuard Trip Unit


The microEntelliGuard trip unit is the newest and most advanced
trip unit available in the Spectra line of molded case circuit
breakers. The trip unit design is based on the EntelliGuard TU trip
unit platform. The microEntelliGuard trip unit incorporates the
advanced features and protective functions available on the
EntelliGuard TU trip unit and is available in the 600-amp
Spectra G and 1200-amp Spectra K frames. Spectra breakers
with microEntelliGuard trip units allow you to select the
enhanced system protection, coordination, metering and commu-
nication options required for the application and allow a fully
coordinated and integrated electrical system across GEs entire
line of molded case, insulated case and low voltage circuit break-
ers. Spectra breakers with microEntelliGuard trip units use all of
the same power management system accessories as the
MicroVersaTrip PM trip units (some new power management Spectra SG600 and SK1200 breakers
accessories are available for breakers that incorporate some of with microEntelliGuard Trip Units
the new features offered with the microEntelliGuard trip unit).
Optional Features
Standard Features Ground Fault (Trip or Alarm) pickup and delay bands with
Adjustable Long-Time pickup and delay bands with three curve multiple slopes, I2t IN/OUT for optimal system coordination
shapes (MVT I2t, CB and Fuse I4t) for optimal system coordina- Neutral Protection provides overload protection on the system
tion (includes thermal memory for enhanced system protection) neutral
Adjustable Short-Time pickup with multiple delay bands, curve Zone Selective Interlocking (ZSI) capability on Short Time,
slopes, I2t IN/OUT, and OFF setting Ground Fault and Instantaneous settings for optimal system
Adjustable Instantaneous pickup coordination and selectivity
3-Phase ammeter Reduced Energy Let-Through (RELT) setting for enhanced
Backlit LCD display with five-button tactile keypad for function equipment and personnel protection
selection and set point adjustment and sealable, clear LEXAN Advanced metering option includes the ability to monitor
cover for tamper resistant settings current, voltage, energy, frequency, power factor, power
LED Status Indicator to show health of trip unit (real/reactive/apparent) and peak power demand
Trip Target indication and local pickup warning signal Modbus communications system with user selectable address
Interchangeable/Universal rating plugs assignment for communication directly with EnerVista Viewpoint
Test set jack for GTUTK20 test kit power system monitoring software
True RMS current sensing for accurate response to high Waveform capture for enhanced system diagnostics
harmonic content waveforms Protective Relays that are user selectable in any combination
EMI immunity per ANSI C37.90 Voltage Unbalance
Current Unbalance
Under Voltage
Over Voltage
Power Reversal
Load Alarm
Input relay for RELT signal or remote tripping of the breaker
Two programmable output relays for enhanced signaling and
diagnostics
Control Power option provides connection capability for +24Vdc
control power via the distribution cable system

Other Features
UL Listed for reverse feed and HACR type (standard)
UL Listed 100% continuous current rating (optional)
UL Listed Current Limiting (optional on SG Frame)
Internal Accessories (Shunt Trip, Undervoltage Release, Auxiliary
Contacts, Bell Alarm) UL Listed for field installation and
common across the entire line of Spectra RMS breakers

6-54 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Molded Case Circuit Breakers Section 6
Industrial Circuit Breakers
Spectra RMS Circuit Breakers with
microEntelliGuard Trip Units

microEntelliGuard Trip Unit Characteristics


Ground Fault
Long Time (C) Short Time Instantaneous & Reduced Energy Let-Through (Trip or Alarm)
0.50 to 1.00 1.5 to 9.0 SK-H, L, P = 2.0 to 10.0 - Instantaneous 0.4 to 1.0
in increments of 0.05 in increments of 0.5 1.5 to 10.0 - RELT in increments of 0.05
(X, multiples of rating plug amps) (multiples of current setting C) in increments of 0.5 (multiples of current sensor amps S)
(X, multiples of current sensor amps)
Pickup Settings
Breaker Sensor Ampere INST
800 2.0 to 25.5
SKS, SKT 1000 2.0 to 20.5
1200 2.0 to 17.0
Delay Bands1
1-12 (.07 to .49) 2-15 (.06 to .92)
Settings (seconds)
MVT 1-4 (I2t) (2.4, 4.9, 9.8, 202)
0 - I2t out 0 - definite time
C1-C10 (thermal) (.2 to 9.6,15.42)
1 - low 1 - I2t
Slope /Shape F1-F7 (I4t) (.02 to 0.9)
2 - med 2 - selective ground fault
3 - high 3 - fuse shape (I4t)

X = Rating Plug Amperes


S = Sensor Ampere Rating
C = Long Time Current Setting Pickup = LT pickup setting x Rating Plug Amperes X
1Delay Bands shown at 600% of current setting at lower limit of each band
2Maximum setting not available on SG

Note: See section 29 for microEntelliGuard time-current curves

Spectra RMS Circuit Breakers with microEntelliGuard Trip Units


Last Digit of Catalog Number Equals >>> X 2 6 8 Advanced Features and Communications

Metering (Basic)
Metering (Advanced)
Modbus
Waveform Capture
Functions Accuracy and Description Protective Relays

Current (A) Amps 4% Phase Selectable


Voltage (V) Volts 2% L-L or L-N and Phase Selectable
Real Power (kW) kWatts 6% L-L or L-N
Reactive Power (kVAR) kVAR 4% L-L or L-N
Apparent Power (kVA) kVA 4% L-L or L-N
Peak Power Demand (kW) kWatts 4%
Energy (kWh/MWh) kWh 7%
Frequency (Hz) 1 Hz
Power Factor (%) 7% max
Communications EnerVista Viewpoint (Modbus)
Waveform Capture COMTRADE file format
Adjustable Pickup 10 to 50%
Voltage Unbalance Relay
Adjustable Delay 1 to 15 sec or OFF
Adjustable Pickup 10 to 50%
Current Unbalance Relay
Adjustable Delay 1 to 15 sec or OFF
Adjustable Pickup 50 to 90%
Under Voltage Relay
Adjustable Delay 1 to 15 sec or OFF
Adjustable Pickup 110 to 150%
Over Voltage Relay
Adjustable Delay 1 to 15 sec or OFF
Adjustable Pickup 10 to 990 KW
Power Reversal Relay
Adjustable Delay 1 to 15 sec or OFF
ON 0.55 to 1.00 x LT
Load Alarm Relay
OFF 0.50 to 0.95 x LT

Rev. 11/13 www.geindustrial.com BuyLog Catalog 6-55


Data subject to change
without notice
Molded Case Circuit Breakers Section 6
Industrial Circuit Breakers
Spectra RMS Circuit Breakers with
microEntelliGuard Trip Units To Voltage Module
microEntelliGuard
Molded-Case Aux. Switch
Circuit
Breaker

How to Order Distribution


Cable Harness

PC 2
PC 1
Select the appropriate breaker frame on the following pages
taking into consideration the maximum ampere rating, the
interrupt rating, whether or not a 100% rating is required, RELT
Junction Breaker
standard protection functions (LSI, LSIG, LSIA), advanced protec- Box Cable
Communications
tion functions (Neut. Prot., ZSI, RELT), and advanced features and
communications (basic or advanced metering, communications,

TIM 1

TIM 1
(ZSI)
waveform capture, protective relays)
Select the rating plug and breaker lugs from the tables provided. From To
Select the required power management system accessories. Breaker Breaker
To Other Junction Boxes
Neutral
Select other accessories as required (such as an auxiliary switch Current
Sensor
or shunt trip).
When ordering, specify separate product numbers for each item Trip Unit Function Definitions
Long-Time (L) Adjustable current setting
Adjustable long-time delay - three curve shapes
Ordering Example (MVT I2t, CB and Fuse I4t)
Short-Time (S) Adjustable short-time pickup (can also be turned OFF)
SG600 ampere frame, standard load rating and 400 maximum Adjustable short-time delay - multiple slope options
ampere rating, 350 amp rating plug with line and load lugs. Trip I2t IN or OUT
Instantaneous (I) Adjustable instantaneous pickup
functions to include adjustable long-time (L), short-time (S), Ground Fault (G) Adjustable ground fault pickup
instantaneous (I), ground fault alarm (A), reduced energy let- Ground Fault Alarm (A) Adjustable ground fault delay - multiple slope options
through (RELT), and advanced metering, communications, with I2t IN or OUT
Control Power (CP) +24Vdc control power connection
waveform capture and protective relays. Metering and communi- Trip Indication Targets Standard
cations of voltage, current, power and breaker contact position Neutral Protection Adjustable current setting on Neutral: multiple of
are required. Local RELT enable is also required. The available Long-Time setting
ZSI (ST/GF/INST) Adjustable Zone Selective Interlock settings for
system voltage is 480/277 Vac 3 phase/4-wire with an available Short-Time, Ground Fault, and Instantaneous
fault current of 65kAIC. Power management accessories are to be RELT Adjustable Instantaneous: Reduced Energy
Let-Through mode
mounted on plates with all of the necessary fuse protection, Metering (basic) Amperes (A/kA) - Phase selectable
potential transformers, control power transformers, and required Metering (advanced) Current (A/kA) - Phase selectable
interconnect accessories. The required circuit breaker Product Voltage (V) - L-L or L-N and Phase selectable
Real Power (kW) - L-L or L-N
Number is SGLC3604L5R8. Reactive Power (kVAR) - L-L or L-N
Apparent Power (kVA) - L-L or L-N
Peak Power Demand (kW)
Description Product Number Energy (kWh/MWh)
Frequency (Hz)
Breaker Prefix SGLC3604L5_ _ Power Factor (%)
Adder 1 for R (RELT) Communications Modbus with user selectable address assignment
Adder 2 for 8 Compatible with EnerVista Viewpoint power system
(Adv Meter/Modbus/WFC/Relay) monitoring software
Complete Breaker SGLC3604L5R8 Waveform Capture Stores 8 cycles of data on trip or signal
Rating Plug GTP0350U0408 (COMTRADE file format)
Lug Kits (2) TCLK365 Protective Relay Functions Voltage Unbalance - pickup/delay/OFF
Auxiliary Switch SAUXGAB1 Current Unbalance - pickup/delay/OFF
RELT Switch Kit GTURSK Under Voltage - pickup/delay/OFF
Power Supply Plate SPSA480 Over Voltage - pickup/delay/OFF
Voltage Conditioner GMPU7 Power Reversal - pickup/delay/OFF
Advanced J-Box SDCJBBC Load Alarm - pickup (ON)/OFF
Distribution Cable Harness (2) SDCHA11
400A Neutral CT TSRG204
Other Features/Functions
HMI - Backlit LCD display & Ease of programming and viewing status/
5-button keypad metering displays, tactile feel
LED Status Indicator Visual display of trip units health
Visual pickup waring signal For quick diagnostics and pre-trip detection
Sealable LEXAN cover for Tamper resistant settings
tamper resistant settings
Test set jack for GTURSK test kit Fully integrated with GTURSK test kit
Long Time Thermal Memory For enhanced system protection
Input Relay1 Dedicated if RELT enabled or set to TRIP/OFF
Qty (2) Programmable Output Contacts1 RELT (dedicated)
Ground Fault Alarm
Overcurrent Trip
Protective Relay Trip
Load Alarm
Health Status
1Included on breakers with 20-pin output harness

6-56 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Molded Case Circuit Breakers Section 6
Industrial Circuit Breakers
Spectra RMS Circuit Breakers with
microEntelliGuard Trip Units

microEntelliGuard Trip Unit Feature and Benefit Summary

Long Time and Short Time

Instantaneous Selectivity
System/Asset Protection

Diagnostics/Reliability
System Performance
Coordination

Arc Flash
Feature Benefit
Enhanced adjustability and flexibility Enhanced system protection via tight coordination with upstream

of time current curve shape, slope, and delay bands and downstream devices including fuses
Ground Fault Trip or Alarm Enhanced system and asset protection - especially for process driven applications
Zone Selective Interlock (ST/GF) System protection
Zone Selective Interlock (Instantaneous) Maximum system protection, coordination, and selectivity
Reduced Energy Let-Through Enhanced system and personnel protection
Protective Relay Functions Enhanced system and asset protection via a suite of protective relays
Neutral Protection Protection on heavy harmonic loads
Sealable LEXAN Trip Unit Cover Prevents unauthorized trip unit setting changes for maximum system, personnel,

and asset protection.
Long Time Thermal Memory Enhanced system protection
Input Relay1 System and asset protection via remote trip (dedicated if RELT enabled)
Programmable Output Contacts1 Maximize system uptime via signaling on GF alarm, overcurrent trip, protective relay trip,

load alarm or health status
Advanced Metering System performance monitoring and diagnostics of critical current, voltage,

and power characteristics
Modbus Communications System performance monitoring, reporting and diagnostics (compatible with

EnerVista Viewpoint power system monitoring software)
Test Set Jack for GTUTK20 Test Kit Maximize system uptime and enhanced diagnostics via the GTUTK20 test kit
Trip Indication Targets Visual Trip indication for quick diagnostic evaluation
Event Log Records last 10 trip events
Waveform Capture Enhanced diagnostic feature to maximize system uptime
HMI - Backlit LCD Display and 5-button Keypad Ease of programming and viewing status/metering displays
LED Status Indicator Enhanced diagnostic feature to maximize system uptime

(visual display of trip units health)
Visual Pickup Warning Signal For quick diagnostics and pre-trip detection

1Included on breakers with 20-pin output harness

Spectra microEntelliGuard
Reference Publications
Spectra G Breaker w/
microEntelliGuard Trip Unit GEH-700
Spectra K Breaker w/
microEntelliGuard Trip Unit GEH-701
Universal Rating Plug DEH-41318
MET Sealable Cover Kits GEH-707
microEntelliGuard Trip Unit Users Manual GEH-702
microEntelliGuard Jump Start
Programming Instructions GEH-703
Distribution Cable Terminal Block (SDCTBA11) GEH-6257
Distribution Cable Terminal Blocks -
MET only (SDCTBA11C & SDCTBA22C) GEH-706
Distribution Cable Junction Box SDCJBB DEH-006
Advanced Distribution Cable Junction Box SDCJBBC GEH-704
Distribution Cable Harness (12-pin) GEH-6255
Distribution Cable Extension (12-pin) GEH-6256
Distribution Cable Extension - MET only (20-pin) GEH-705
Power Supply Plate GEH-6251
Power Supply Assembly GEH-6253
Voltage Conditioner GMPU GEH-6259
Voltage Conditioner SVCAA - OBSOLETE GEH-6254
Voltage Conditioner Plate SVCA - OBSOLETE GEH-6252
Voltage Module ADSVMA - OBSOLETE GEH-6250
GTU Digital Test Kit (GTUTK20) DEH-4568
Shunt Trip and UVR Instructions GEH-5551
Aux Switch and Bell Alarm GEH-5593
Accessories - Door Ring Interlock Catch Kits GEI-70594
TIM-1 Zone Selective Interlock Module GEK-64467

Rev. 11/13 www.geindustrial.com BuyLog Catalog 6-57


Data subject to change
without notice
Molded Case Circuit Breakers Section 6
Industrial Circuit Breakers
60-600A Circuit Breakers
Electronic Trip
Spectra RMS
SG600 with microEntelliGuard Trip Units1
Product Number Structure
S G H C 3 6 01 L3 X X

Standard
Frame Rating Voltage Protection Advanced Features &
Family (Amperes) Poles Rating Functions Communications
S = Spectra G = 600 3 = 3 poles 6 = 600V L3 = LSI2 X = Metering (Basic)
L4 = LSIG 2 = Metering (Basic) +
L5 = LSIA Modbus
Continuous
L7 = LSI-CP3 6 = Metering (Adv) +
Load Rating
Modbus +
C = Standard Waveform Capture
H = 100% Max Amps 8 = Metering (Adv) +
L = 100% 01 = 150A Modbus +
P = 100% 04 = 400A Waveform Capture +
06 = 600A Protective Relays
Interruption Rating
(kA @ 480V)
H = 35 Advanced Protection Functions
L = 65 X = None
P = 100 K = Neutral Protection
Z = ZSI (ST/GF)
T = ZSI (ST/GF/INST)
R = RELT
L = ZSI (ST/GF) + RELT
M = ZSI (ST/GF) +
Note: This information is provided for interpreting product numbers (it should not be used to build product numbers).
L = Long Time, S = Short Time, I = Instantaneous, G = Ground Fault, A = Ground Fault Alarm
Neutral Protection
ZSI = Zone Selective Interlocking, RELT = Reduced Energy Let-Through N = ZSI (ST/GF) + RELT +
Neutral Protection
2Without a Control Power connection, unless required by Advanced Protection Functions or Advanced Features
V = RELT + Neutral Protection
& Communications. P = ZSI (ST/GF/INST) + RELT
3With a Control Power connection. The only valid trailing product digits for L7 are XX.
S = ZSI (ST/GF/INST) +
Note: All Spectra breakers are UL listed as HACR type. Neutral Protection
W = ZSI (ST/GF/INST) + RELT +
Neutral Protection

microEntelliGuard Rating Plug Selection Terminal Lugs for


Rating Plug SG (Max Amps) Front Connection (Cu/Al)
Product Numbers Trip Amps 150 400 600
Product
GTP0060U0101 60 x Sensor Number Wire Range
GTP0080U0101 80 x
(2) 2/0 - 500 Cu/Al
GTP0100U0103 100 x
or
GTP0125U0103 125 x 3 Pole Lug Kit
150 to 600 (1) 8 - 600 Cu
GTP0150U0104 150 x x TCLK3654
or
GTP0200U0204 200 x
(1) 6 - 600 Al
GTP0225U0306 225 x x
GTP0250U0407 250 x x
GTP0300U0408 300 x x
GTP0350U0408 350 x x 1May require 24 Vdc control power and voltage sensing
GTP0400U0410 400 x x signals. Refer to pages 6-62 to 6-68.
GTP0450U0612 450 x 4Order one kit for either line or load end: two kits
GTP0500U0613 500 x required for both.
GTP0600U0616 600 x
Note: Reference BuyLog page 6-104 for alternate
Range of available rating plugs for each frame lug options.
indicated by x.

6-58 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Molded Case Circuit Breakers Section 6
Industrial Circuit Breakers
60-600A Circuit Breakers
Electronic Trip
Spectra RMS
SG600 with microEntelliGuard Trip Units1
microEntelliGuard, Standard UL Rated
SG600 Line, Suitable for Reverse Feed, UL File E-11592, CSA LR 40350
SGL, SGP UL Current Limiting; 3-Pole, UL/CSA: 600Vac Max., IEC 947-2: 630A, 690 Vac Max

Standard 35kA 65kA 100kA Product Number


Max Protection Product Number Product Number Product Number Suffix
Amps Function Prefix Prefix Prefix (two digits)
LSI SGHC3601L3 _ _ SGLC3601L3 _ _ SGPC3601L3 _ _
LSIG2 SGHC3601L4 _ _ SGLC3601L4 _ _ SGPC3601L4 _ _
150
LSIA2 SGHC3601L5 _ _ SGLC3601L5 _ _ SGPC3601L5 _ _
LSI-CP3 SGHC3601L7XX SGLC3601L7XX SGPC3601L7XX Product Number is
LSI SGHC3604L3 _ _ SGLC3604L3 _ _ SGPC3604L3 _ _ not complete.
LSIG2 SGHC3604L4 _ _ SGLC3604L4 _ _ SGPC3604L4 _ _
400
LSIA2 SGHC3604L5 _ _ SGLC3604L5 _ _ SGPC3604L5 _ _ Select one value
LSI-CP3 SGHC3604L7XX SGLC3604L7XX SGPC3604L7XX from each suffix
LSI SGHC3606L3 _ _ SGLC3606L3 _ _ SGPC3606L3 _ _ tables below.
LSIG2 SGHC3606L4 _ _ SGLC3606L4 _ _ SGPC3606L4 _ _
600
LSIA2 SGHC3606L5 _ _ SGLC3606L5 _ _ SGPC3606L5 _ _
LSI-CP3 SGHC3606L7XX SGLC3606L7XX SGPC3606L7XX

microEntelliGuard, 100% UL Rated


SG600 Line, Suitable for Reverse Feed, UL File E-11592, CSA LR 40350
SGL, SGP UL Current Limiting; 3-Pole, UL/CSA: 600Vac Max., IEC 947-2: 630A, 690 Vac Max

Standard 35kA 65kA 100kA Product Number


Max Protection Product Number Product Number Product Number Suffix
Amps Function Prefix Prefix Prefix (two digits)
LSI SGHH3601L3 _ _ SGLL3601L3 _ _ SGPP3601L3 _ _
LSIG2 SGHH3601L4 _ _ SGLL3601L4 _ _ SGPP3601L4 _ _
150
LSIA2 SGHH3601L5 _ _ SGLL3601L5 _ _ SGPP3601L5 _ _
LSI-CP3 SGHH3601L7XX SGLL3601L7XX SGPP3601L7XX Product Number is
LSI SGHH3604L3 _ _ SGLL3604L3 _ _ SGPP3604L3 _ _ not complete.
LSIG2 SGHH3604L4 _ _ SGLL3604L4 _ _ SGPP3604L4 _ _
400
LSIA2 SGHH3604L5 _ _ SGLL3604L5 _ _ SGPP3604L5 _ _ Select one value
LSI-CP3 SGHH3604L7XX SGLL3604L7XX SGPP3604L7XX from each suffix
LSI SGHH3606L3 _ _ SGLL3606L3 _ _ SGPP3606L3 _ _ tables below.
LSIG2 SGHH3606L4 _ _ SGLL3606L4 _ _ SGPP3606L4 _ _
600
LSIA2 SGHH3606L5 _ _ SGLL3606L5 _ _ SGPP3606L5 _ _
LSI-CP3 SGHH3606L7XX SGLL3606L7XX SGPP3606L7XX

Product Suffix 1 Product Suffix 2


Advanced Protection Functions Advanced Features and Communications
X = None X = Metering (Basic)
K = Neutral Protection 2 = Metering (Basic) + Modbus
Z = ZSI (ST/GF) 6 = Metering (Adv) + Modbus +
T = ZSI (ST/GF/INST) Waveform Capture
R = RELT 8 = Metering (Adv) + Modbus +
L = ZSI (ST/GF) + RELT Waveform Capture + Relays
M = ZSI (ST/GF) + Neutral Protection
N = ZSI (ST/GF) + RELT + Neutral Protection
V = RELT + Neutral Protection
P = ZSI (ST/GF/INST) + RELT
S = ZSI (ST/GF/INST) + Neutral Protection
W = ZSI (ST/GF/INST) + RELT + Neutral Protection

1May require 24 Vdc control power and voltage sensing Notes: All Spectra breakers are UL listed as HACR type.
signals. Refer to pages 6-62 to 6-68. Neutral Protection requires a neutral current sensor. Refer to page 6-66.
2For grounded neutral systems (1 phase/3-wire or ZSI (Zone Selective Interlock) requires TIM1 ZSI module and 24 Vdc control power (refer to pages 6-62 to
3 phase/4-wire) a neutral current sensor is required. 6-66 for accessories).
Refer to page 6-66. RELT (Reduced Energy Let-Through), Modbus, Ground Fault Alarm and Waveform Capture options require
3For +24 Vdc Control Power Accessories refer to pages 24 Vdc control power
6-62 to 6-66. (refer to pages 6-62 to 6-66 for accessories).

Rev. 11/13 www.geindustrial.com BuyLog Catalog 6-59


Data subject to change
without notice
Molded Case Circuit Breakers Section 6
Industrial Circuit Breakers
300-1200A Circuit Breakers
Electronic Trip
Spectra RMS
SK1200 with microEntelliGuard Trip Units1
Product Number Structure
S K H C 3 6 08 L3 X X

Standard
Frame Rating Voltage Protection Advanced Features &
Family (Amperes) Poles Rating Functions Communications
S = Spectra K = 1200 3 = 3 poles 6 = 600V L3 = LSI3 X = Metering (Basic)
4 = 480V5 L4 = LSIG 2 = Metering (Basic) +
L5 = LSIA Modbus
Continuous
L7 = LSI-CP4 6 = Metering (Adv) +
Load Rating
Modbus +
C = Standard Waveform Capture
H = 100% Max Amps 8 = Metering (Adv) +
L = 100% 08 = 800A Modbus +
P = 100% 10 = 1000A2 Waveform Capture +
S = 100% 12 = 1200A Protective Relays
T = 100%
Interruption Rating
(kA @ 480V) Advanced Protection Functions
H = 50 X = None
L = 65 K = Neutral Protection
P = 100 Z = ZSI (ST/GF)
T = 65 Extended Instantaneous (Selective)5 T = ZSI (ST/GF/INST)
S = 100 Extended Instantaneous (Selective)5 R = RELT
L = ZSI (ST/GF) + RELT
M = ZSI (ST/GF) +
Note: This information is provided for interpreting product numbers (it should not be used to build product numbers).
Neutral Protection
L = Long Time, S = Short Time, I = Instantaneous, G = Ground Fault, A = Ground Fault Alarm
ZSI = Zone Selective Interlocking, RELT = Reduced Energy Let-Through N = ZSI (ST/GF) + RELT +
Neutral Protection
2Max Amps Option 10 only available on 100% rated breakers. V = RELT + Neutral Protection
3Without a Control Power connection, unless required by Advanced Protection Functions or Advanced Features
P = ZSI (ST/GF/INST) + RELT
& Communications.
4With a Control Power connection. The only valid trailing product digits for L7 are XX.
S = ZSI (ST/GF/INST) +
5SC, SS, TC and TT catalog codes are optimized for selectivity (extended instantaneous) and will carry a 480 Vac Neutral Protection
maximum voltage rating. W = ZSI (ST/GF/INST) + RELT +
Neutral Protection
Note: All Spectra breakers are UL listed as HACR type.

microEntelliGuard Rating Plug Selection Terminal Lugs for


Rating Plug SK (Max Amps) Front Connection (Cu/Al)
Product Numbers Trip Amps 800 1000 1200
Product
GTP0300U0408 300 x Sensor Number Wire Range
GTP0350U0408 350 x
800 TCAL81 (3) 3/0 - 500 Cu/Al
GTP0400U0410 400 x
12006 TCAL125 (4) 3/0 - 500 Cu/Al
GTP0450U0612 450 x x x
GTP0500U0613 500 x x x
GTP0600U0616 600 x x x
1May require 24 Vdc control power and voltage sensing
GTP0700U0816 700 x x x
GTP0750U0820 750 x x x signals. Refer to pages 6-62 to 6-68.
GTP0800U0820 800 x x x 6Lugs not required on 100% rated SK1200; these
GTP0900U1020 900 x x breakers are supplied with a back-connected
GTP1000U1025 1000 x x assembly which increases breaker depth. Refer to
GTP1100U1225 1100 x outline drawing 168D1663 Sh1 for details.
GTP1200U1232 1200 x
Note: Reference BuyLog page 6-104 for alternate
Range of available rating plugs for each frame lug options.
indicated by x.

6-60 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Molded Case Circuit Breakers Section 6
Industrial Circuit Breakers
300-1200A Circuit Breakers
Electronic Trip
Spectra RMS
SK1200 with microEntelliGuard Trip Units1
microEntelliGuard, Standard UL Rated
SK1200 Line, Suitable for Reverse Feed, UL File E-11592, CSA LR 40350
3-Pole, UL/CSA: 600Vac Max., IEC 947-2: 1250A, 690 Vac Max (SKL, SKP only)
Standard 50kA 65kA 100kA Product Number
Max Protection Product Number Product Number Product Number Suffix
Amps Function Prefix Prefix Prefix (two digits)
LSI SKHC3608L3 _ _ SKLC3608L3 _ _ SKPC3608L3 _ _
LSIG2 SKHC3608L4 _ _ SKLC3608L4 _ _ SKPC3608L4 _ _ Product Number is
800 not complete.
LSIA2 SKHC3608L5 _ _ SKLC3608L5 _ _ SKPC3608L5 _ _
LSI-CP3 SKHC3608L7XX SKLC3608L7XX SKPC3608L7XX
LSI SKHC3612L3 _ _ SKLC3612L3 _ _ SKPC3612L3 _ _ Select one value
LSIG2 SKHC3612L4 _ _ SKLC3612L4 _ _ SKPC3612L4 _ _ from each suffix
1200 tables below.
LSIA2 SKHC3612L5 _ _ SKLC3612L5 _ _ SKPC3612L5 _ _
LSI-CP3 SKHC3612L7XX SKLC3612L7XX SKPC3612L7XX

microEntelliGuard, 100% UL Rated


SK1200 Line, Suitable for Reverse Feed, UL File E-11592, CSA LR 40350
3-Pole, UL/CSA: 600Vac Max., IEC 947-2: 1250A, 690 Vac Max (SKL, SKP only)
Standard 50kA 65kA 100kA Product Number
Max Protection Product Number Product Number Product Number Suffix
Amps Function Prefix Prefix Prefix (two digits)
LSI SKHH3608L3 _ _ SKLL3608L3 _ _ SKPP3608L3 _ _
LSIG2 SKHH3608L4 _ _ SKLL3608L4 _ _ SKPP3608L4 _ _
800
LSIA2 SKHH3608L5 _ _ SKLL3608L5 _ _ SKPP3608L5 _ _
LSI-CP3 SKHH3608L7XX SKLL3608L7XX SKPP3608L7XX Product Number is
LSI SKHH3610L3 _ _ SKLL3610L3 _ _ SKPP3610L3 _ _ not complete.
LSIG2 SKHH3610L4 _ _ SKLL3610L4 _ _ SKPP3610L4 _ _
1000
LSIA2 SKHH3610L5 _ _ SKLL3610L5 _ _ SKPP3610L5 _ _ Select one value
LSI-CP3 SKHH3610L7XX SKLL3610L7XX SKPP3610L7XX from each suffix
LSI SKHH3612L3 _ _ SKLL3612L3 _ _ SKPP3612L3 _ _ tables below.
LSIG2 SKHH3612L4 _ _ SKLL3612L4 _ _ SKPP3612L4 _ _
1200
LSIA2 SKHH3612L5 _ _ SKLL3612L5 _ _ SKPP3612L5 _ _
LSI-CP3 SKHH3612L7XX SKLL3612L7XX SKPP3612L7XX

microEntelliGuard Extended Instantaneous (Selective) Spectra K


SK1200 Line, Suitable for Reverse Feed, UL File E-11592, CSA LR 40350, 3-Pole, UL/CSA: 480 Vac Max., IEC 947-2: 1250A
Standard UL Rated 100% UL Rated Standard UL Rated 100% UL Rated Product
Standard 65kA 65kA 100kA 100kA Number
Max Protection Product Number Product Number Product Number Product Number Suffix
Amps Function Prefix Prefix Prefix Prefix (two digits)
LSI SKTC3408L3_ _ SKTT3408L3_ _ SKSC3408L3_ _ SKSS3408L3_ _
800 LSIG2 SKTC3408L4 _ _ SKTT3408L4 _ _ SKSC3408L4 _ _ SKSS3408L4 _ _
LSIA2 SKTC3408L5_ _ SKTT3408L5_ _ SKSC3408L5_ _ SKSS3408L5_ _
LSI-CP3 SKTC3408L7XX SKTT3408L7XX SKSC3408L7XX SKSS3408L7XX Product Number is
LSI SKTT3410L3_ _ SKSS3410L3_ _ not complete.

1000 LSIG2 SKTT3410L4 _ _ SKSS3410L4 _ _


LSIA2 SKTT3410L5_ _ SKSS3410L5_ _ Select one value
LSI-CP3 SKTT3410L7XX SKSS3410L7XX from each suffix
LSI SKTC3412L3_ _ SKTT3412L3_ _ SKSC3412L3_ _ SKSS3412L3_ _ tables below.

1200 LSIG2 SKTC3412L4 _ _ SKTT3412L4 _ _ SKSC3412L4 _ _ SKSS3412L4 _ _


LSIA2 SKTC3412L5_ _ SKTT3412L5_ _ SKSC3412L5_ _ SKSS3412L5_ _
LSI-CP3 SKTC3412L7XX SKTT3412L7XX SKSC3412L7XX SKSS3412L7XX

Product Suffix 1 Product Suffix 2


Advanced Protection Functions Advanced Protection Functions Advanced Features and Communications
X = None M = ZSI (ST/GF) + Neutral Protection X = Metering (Basic)
K = Neutral Protection N = ZSI (ST/GF) + RELT + Neutral Protection 2 = Metering (Basic) + Modbus
Z = ZSI (ST/GF) V = RELT + Neutral Protection 6 = Metering (Adv) + Modbus +
T = ZSI (ST/GF/INST) P = ZSI (ST/GF/INST) + RELT Waveform Capture
R = RELT S = ZSI (ST/GF/INST) + Neutral Protection 8 = Metering (Adv) + Modbus +
L = ZSI (ST/GF) + RELT W = ZSI (ST/GF/INST) + RELT + Neutral Protection Waveform Capture + Relays
1May require 24 Vdc control power and voltage sensing signals.
Refer to pages 6-62 to 6-68. Notes: All Spectra breakers are UL listed as HACR type.
2For grounded neutral systems (1 phase/3-wire or 3 phase/4-wire) a Neutral Protection requires a neutral current sensor. Refer to page 6-66.
neutral current sensor is required. Refer to page 6-66. ZSI (Zone Selective Interlock) requires TIM1 ZSI module and 24 Vdc control power (refer to pages 6-62 to
3For +24 Vdc Control Power Accessories refer to pages 6-62 to 6-66. 6-66 for accessories).
RELT (Reduced Energy Let-Through), Modbus, Ground Fault Alarm and Waveform Capture options require
24 Vdc control power (refer to pages 6-62 to 6-66 for accessories).

Rev. 11/13 www.geindustrial.com BuyLog Catalog 6-61


Data subject to change
without notice
Molded Case Circuit Breakers Section 6
Power Management System Accessories
Spectra RMS Circuit Breakers with microEntelliGuard, MicroVersaTrip Plus and MicroVersaTrip PM Trip Units
All Devices UL Listed for Factory or Field Installation (UL File No. E-57253)

Required Accessories
MicroVersaTrip Plus MicroVersaTrip PM microEntelliGuard Feature Required Accessories
Neutral Protection Neutral CT
Terminal Board (or Junction Box)
Ground Fault (3 phase/4-wire or 1 phase/3-wire) Distribution Cable(s)
Ground Fault Alarm (3 phase/4-wire or 1 phase/3-wire) Power Supply Plate/Assy2 for GFA only1
Control Power Power Supply Plate/Assy2
Power Supply (Plate or Assy2)
Voltage Conditioner
Advanced Metering, Protective Relays
Terminal Board (or Junction Box)
Distribution Cable(s)
Power Supply Plate/Assy2
Terminal Board (or Junction Box)
Communications3
Distribution Cable(s)
Auxiliary Switch4
Power Supply Plate/Assy2
Terminal Board with ZSI (or Advanced Junction Box)
Zone Selective Interlock (ZSI)
Distribution Cable(s)
TIM-1 module
Power Supply Plate/Assy2
Reduced Energy Let-Through (RELT) Terminal Board with RELT (or Advanced Junction Box)
Distribution Cable(s)
Power Supply Plate/Assy2
Waveform Capture Terminal Board (or Advanced Junction Box)
Distribution Cable(s)
1Power supply required for Ground Fault Alarm only. 3MicroVersaTrip PM (Commnet), microEntelliGuard (Modbus)
2Requires fuse protection and other components - refer to accessory instruction sheet 4Requires Auxiliary Switch with gold-plated contacts

Power Supply
The Power Supply Plate is used to provide +24 Vdc control power to Spectra RMS
molded case circuit breakers with microEntelliGuard, MicroVersaTrip Plus and
MicroVersaTrip PM trip units via the Distribution Cable System. The Power Supply
Plate includes the Power Supply Assembly (product number SPSAA) as an integral
component and also includes fuse protection for AC source input. Supplemental +24 Vdc
input terminals are provided for backup control power applications. Not suitable for
400 Hz.
Description Voltage Rating Product Number
The Power Supply Plate is rated 24 watts 120 Vac SPSA120 Power Supply Plate
(+24 Vdc at 1.0 amperes) and has the maximum 208 Vac SPSA208
capacity to power a distribution Cable System 240 Vac SPSA240
consisting of 20 breakers and has a maximum 480 Vac SPSA480
system cable length of 40 feet. 600 Vac SPSA600

Voltage Conditioner
The Voltage Conditioner is used to provide voltage sensing signals to Spectra RMS
molded case circuit breakers with microEntelliGuard and MicroVersaTrip PM trip units
via the distribution cable system. The GMPU Voltage Conditioner includes internal power
transformers. It replaces the SVCA voltage conditioner plates and is DIN rail mountable.
The Voltage Conditioner requires a control power source of +24 Vdc to operate properly.
The Power Supply Assembly or Power Supply Plate can provide this required input. The
unit also requires AC direct voltage inputs from the AC source. A communications
network connection is provided. Not suitable for 400 Hz.
Voltage Conditioner
OBSOLETE
Voltage
Conditioner Plate Replacement
Product Number Voltage Rating and Service Type Comments Product Number Voltage Rating and Service Type
SVCA120Y 120 Vac Wye system Phase to Neutral potential
GMPU5 120, 208, 230 Vac systems
SVCA208Y 208 Vac Wye system Phase to Phase potential
SVCA240D 240 Vac Delta system Phase to Phase potential
GMPU6 240, 277, 340 Vac systems
SVCA277Y 277 Vac Wye system Phase to Neutral potential
SVCA480Y 480 Vac Wye system Phase to Phase potential
SVCA480D 480 Vac Delta system Phase to Phase potential GMPU7 400, 480, 600 Vac systems
SVCA600D 600 Vac Delta system Phase to Phase potential

Note: The Voltage Conditoner has the maximum capacity to power a Distribution Cable System consisting of 20 breakers and has a maximum system cable length of 40 feet.

6-62 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Molded Case Circuit Breakers Section 6
Power Management System Accessories
Spectra RMS Circuit Breakers with microEntelliGuard, MicroVersaTrip Plus and MicroVersaTrip PM Trip Units
All Devices UL Listed for Factory or Field Installation (UL File No. E-57253)

Distribution Cable Junction Box


The Distribution Cable Junction Box is a modular connector used to provide quick,
easy and reliable attachment of Spectra RMS molded case circuit breakers with
microEntelliGuard, MicroVersaTrip Plus and MicroVersaTrip PM trip units to the
Distribution Cable System. Two different juntion boxes are available depending on which
trip system and functionality is selected. Each junction box contains two Distribution
Cable Harness connectors, one breaker connector, and a terminal block for the
connection of a neutral current sensor and an auxiliary switch. Additional terminal Distribution Cable Junction Box
points are included on SDCJBBC for ground fault alarm, RELT, and ZSI. (For breakers
with microEntelliGuard trip units, refer to the table on page 6-64 to determine breaker
harness connector configuration)
Description Product Number
Distribution Cable Junction Box (for breakers with 12-pin connector) SDCJBB
Advanced Distribution Cable Junction Box (for breakers with 20-pin connector) SDCJBBC2

Distribution Cable Harness1


The Distribution Cable Harness is a modular connector used to carry electronic signals
and/or control power between Spectra RMS molded case circuit breakers with
microEntelliGuard, MicroVersaTrip Plus and MicroVersaTrip PM trip units and
power management system accessories. The harnesses come in three lengths and
have 12-pin connectors at both ends.
Description Harness Length Product Number Distribution Cable Harness
Distribution Cable Harness 11 inches SDCHA11
Distribution Cable Harness 30 inches SDCHA30
Distribution Cable Harness 60 inches SDCHA60

Distribution Cable Extension


The Distribution Cable Extension is used to provide modular expansion of the Distribution
Cable System. Two different cable extensions are available depending on which trip
system and functionality are selected. Spectra RMS molded case circuit breakers
with MicroVersaTrip Plus and MicroVersaTrip PM trip units use the 12-pin
connector extension cable only. Spectra RMS molded case circuit breakers with
microEntelliGuard trip units use either the 12-pin or 20-pin connector extension cable
depending on the breakers harness connector configuration. (For breakers with
microEntelliGuard trip units, refer to the table on page 6-64 to determine breaker
harness connector configuration) Distribution Cable Extension
Description Harness Length Product Number
Distribution Cable Extension (for breakers with 12-pin connector) 30 inches SDCEA30
Distribution Cable Extension (for breakers with 20-pin connector) 30 inches SDCEA30C2

Distribution Cable Terminal Block


The Distribution Cable Terminal Block can be used in lieu of the Distribution Cable
Junction Box as an alternate means of connection to Spectra RMS molded case circuit
breakers with microEntelliGuard, MicroVersaTrip Plus and MicroVersaTrip PM trip
units. The Distribution Cable Terminal Block plugs into the breaker harness connector
allowing direct connection of signals via screw terminals. This allows point-to-point
wiring in lieu of using the Distribution Cable System. Three different cable extensions are
available depending on which trip system and functionality are selected. (Refer to the
table on page 6-64 for terminal block connection configurations)
Description Trip Unit Type Product Number
Distribution Cable Terminal Block MicroVersaTrip & microEntelliGuard SDCTBA11
(for breakers with 12-pin connector)
Distribution Cable Terminal Block microEntelliGuard SDCTBA11C2
(for breakers with 20-pin connector) microEntelliGuard SDCTBA22C2 Distribution Cable Terminal Block
1Cannot be connected together. Use 30 inch Distribution Cable Extension (SDCEA30) to extend.
2For use with microEntelliGuard only.

Rev. 11/13 www.geindustrial.com BuyLog Catalog 6-63


Data subject to change
without notice
Molded Case Circuit Breakers Section 6
Power Management System Accessories
Spectra RMS Circuit Breakers with microEntelliGuard, MicroVersaTrip Plus and MicroVersaTrip PM Trip Units
All Devices UL Listed for Factory or Field Installation (UL File No. E-57253)

Breakers with microEntelliGuard Trip Units Distribution Cable Terminal Block Connection Configurations
Breaker Harness Connector Configuration Terminal SDCTBA11 SDCTBA11C SDCTBA22C
Description 12-pin Connector 20-pin Connector 20-pin Connector
Circuit Breaker Catalog Digits 9 & 10
MicroVersaTrip & microEntelliGuard microEntelliGuard
L3 L4 L5 L7
Trip Unit Type microEntelliGuard only only
K2 SDCTBA11 SDCTBA11 SDCTBA22C n/a
POWER (+24Vdc)
K6 SDCTBA11 SDCTBA11 SDCTBA22C n/a
POWER (common)
K8 SDCTBA22C SDCTBA22C SDCTBA22C n/a
Communications +
KX SDCTBA11 SDCTBA11 SDCTBA11C n/a
Communications -
L2 SDCTBA22C SDCTBA22C SDCTBA22C n/a
Aux Switch (red)
L6 SDCTBA22C SDCTBA22C SDCTBA22C n/a
Aux Switch (white)
L8 SDCTBA22C SDCTBA22C SDCTBA22C n/a
Voltage - Ph A
LX SDCTBA22C SDCTBA22C SDCTBA22C n/a
Voltage - Ph B
M2 SDCTBA22C SDCTBA22C SDCTBA22C n/a
Voltage - Ph C
M6 SDCTBA22C SDCTBA22C SDCTBA22C n/a
Neutral CT (black)
M8 SDCTBA22C SDCTBA22C SDCTBA22C n/a
Neutral CT (white)
MX SDCTBA22C SDCTBA22C SDCTBA22C n/a
ZSI input +
N2 SDCTBA22C SDCTBA22C SDCTBA22C n/a
ZSI input -
N6 SDCTBA22C SDCTBA22C SDCTBA22C n/a
ZSI output +
N8 SDCTBA22C SDCTBA22C SDCTBA22C n/a
ZSI output -
NX SDCTBA22C SDCTBA22C SDCTBA22C n/a
RELT input +
P2 SDCTBA22C SDCTBA22C SDCTBA22C n/a
RELT input -
P6 SDCTBA22C SDCTBA22C SDCTBA22C n/a
RELT output +
Circuit Breaker Catalog Digits 11 & 12

P8 SDCTBA22C SDCTBA22C SDCTBA22C n/a


RELT /GFA output -
PX SDCTBA22C SDCTBA22C SDCTBA22C n/a
GFA output +
R2 SDCTBA22C SDCTBA22C SDCTBA22C n/a
R6 SDCTBA22C SDCTBA22C SDCTBA22C n/a
R8 SDCTBA22C SDCTBA22C SDCTBA22C n/a
RX SDCTBA11C SDCTBA11C SDCTBA11C n/a
S2 SDCTBA22C SDCTBA22C SDCTBA22C n/a
S6 SDCTBA22C SDCTBA22C SDCTBA22C n/a
S8 SDCTBA22C SDCTBA22C SDCTBA22C n/a
SX SDCTBA22C SDCTBA22C SDCTBA22C n/a
T2 SDCTBA22C SDCTBA22C SDCTBA22C n/a
T6 SDCTBA22C SDCTBA22C SDCTBA22C n/a
T8 SDCTBA22C SDCTBA22C SDCTBA22C n/a
TX SDCTBA22C SDCTBA22C SDCTBA22C n/a
V2 SDCTBA22C SDCTBA22C SDCTBA22C n/a
V6 SDCTBA22C SDCTBA22C SDCTBA22C n/a
V8 SDCTBA22C SDCTBA22C SDCTBA22C n/a
VX SDCTBA11C SDCTBA11C SDCTBA11C n/a
W2 SDCTBA22C SDCTBA22C SDCTBA22C n/a
W6 SDCTBA22C SDCTBA22C SDCTBA22C n/a
W8 SDCTBA22C SDCTBA22C SDCTBA22C n/a
WX SDCTBA22C SDCTBA22C SDCTBA22C n/a
X2 SDCTBA11 SDCTBA11 SDCTBA22C n/a
X6 SDCTBA11 SDCTBA11 SDCTBA22C n/a
X8 SDCTBA22C SDCTBA22C SDCTBA22C n/a
XX NONE SDCTBA11 SDCTBA11C SDCTBA11
Z2 SDCTBA22C SDCTBA22C SDCTBA22C n/a
Z6 SDCTBA22C SDCTBA22C SDCTBA22C n/a
Z8 SDCTBA22C SDCTBA22C SDCTBA22C n/a
ZX SDCTBA22C SDCTBA22C SDCTBA22C n/a

6-64 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Molded Case Circuit Breakers Section 6
Power Management System Accessories
Spectra RMS Circuit Breakers with microEntelliGuard, MicroVersaTrip Plus and MicroVersaTrip PM Trip Units
All Devices UL Listed for Factory or Field Installation (UL File No. E-57253)

Power Supply Assembly


The Power Supply Assembly is used to provide +24 Vdc control power to Spectra RMS
molded case circuit breakers with microEntelliGuard, MicroVersaTrip Plus and
MicroVersaTrip PM trip units via the Distribution Cable System. The assembly requires
a minimum input voltage of 85 Vac to operate properly (the maximum voltage rating is
240 Vac). Supplemental +24 Vdc input terminals are provided for backup control power
applications. The input must be fused with 1/2 ampere class CC fuses (not included).
Not suitable for 400 Hz.
Description Voltage Rating Product Number
The Power Supply Assembly is rated 24 watts 85 - 240 Vac SPSAA
(+24 Vdc @ 1.0 ampere) and has the maximum Power Supply Assembly
capacity to power a Distribution Cable System
consisting of 20 breakers and has a maximum
system cable length of 40 feet.

Voltage Conditioner Assembly


The Voltage Conditioner Assembly is used to provide voltage sensing signals to Spectra

E TE
RMS molded case circuit breakers with microEntelliGuard, MicroVersaTrip Plus and
O L
OBS E WITH
MicroVersaTrip PM trip units via the Distribution Cable System. The Voltage Conditioner
Assembly requires a control power source of +24 Vdc to operate properly (the Power

P AC V I C E
Supply Assembly or Power Supply Plate can provide this required input). The unit also
L
requires 120 Vac voltage inputs from the secondary of three 1-VA high accuracy
E
R D E
potential transformers (not included). The primary side of the potential transformers
U
GMP
must be fused with three, 1/2 ampere class CC fuses (not included). A communications
network connection is provided. Not suitable for 400 Hz.
Description Voltage Rating Product Number
Requires 120 Vac voltage inputs from the 120 Vac SVCAA
Voltage Conditioner Assembly
secondary of three 1.0 VA high accuracy
potential transformers

Note: the Voltage Conditioner Assembly has the maximum capacity to power a Distribution Cable System
consisting of 20 breakers and has a maximum system cable length of 40 feet.

Voltage Modules
The Voltage Module is used as a Spectra Series Switchboard component to provide
+24 Vdc control power to Spectra RMS molded case circuit breakers with
microEntelliGuard, MicroVersaTrip Plus and MicroVersaTrip PM trip units via the

E T E
Distribution Cable System. The Voltage Module also provides voltage sensing signals to
L
O T
O B S AC E M E N
Spectra RMS molded case circuit breakers with microEntelliGuard and MicroVersaTrip
PM trip units on the same Distribution Cable System. The Voltage Module contains both

PL
a Power Supply Plate and a Voltage Conditioner as integral components. It also includes

R E
fuse protection for the AC source input terminals (the modules pressure connectors

NO
which connect to the switchboard bus bars). A communication network connection is
provided as well as supplemental +24 Vdc input terminals for backup control power
applications (microEntelliGuard trip units communicate via Modbus; MicroVersaTrip PM
Voltage Module Exterior View

communicate via Commnet). Seven versions are available. Not suitable for 400 Hz.
Voltage Rating and Service Type Comments Product Number
120 Vac Wye system Phase to Neutral potential ADSVMA120Y
208 Vac Wye system Phase to Phase potential ADSVMA208Y
240 Vac Delta system Phase to Phase potential ADSVMA240D
277 Vac Wye system Phase to Neutral potential ADSVMA277Y
480 Vac Wye system Phase to Phase potential ADSVMA480Y
480 Vac Delta system Phase to Phase potential ADSVMA480D
600 Vac Delta system Phase to Phase potential ADSVMA600D

Note: The Voltage Module has the maximum capacity to power a Distribution Cable System consisting of 20
breakers and has a maximum system cable length of 40 feet.
Voltage Module Interior View

Rev. 11/13 www.geindustrial.com BuyLog Catalog 6-65


Data subject to change
without notice
Molded Case Circuit Breakers Section 6
AccessoriesOther
Spectra RMS Circuit Breakers with microEntelliGuard, MicroVersaTrip Plus and MicroVersaTrip PM Trip Units
All Devices UL Listed for Factory or Field Installation Except Where Noted

Neutral Current Sensor


The Neutral Current Sensor is used in conjunction with Spectra RMS molded case circuit
breakers with microEntelliGuard, MicroVersaTrip Plus and MicroVersaTrip PM trip units
that are optioned with either the ground fault or neutral protection and the breaker is
connected to a grounded neutral service (3 phase/4-wire or 1 phase/3-wire). The neutral
current sensor provides an input signal to the breaker trip unit. Breakers connected to a
service without a neutral (3 phase/3-wire) do not require an external connection or short-
ing of the breaker cable connector for ground fault to function properly.
Breaker Type Sensor Rating (S) Product Number
Neutral Current Sensor
SG 150 TSRG201
SG 400 TSRG204
SG 600 TSRG206
SK 800 TSKG408
SK 1200 TSKG412

Rating Plug Removal Tool


The Rating Plug Removal Tool is suitable for use on all Spectra RMS molded case circuit
breakers, regardless of the trip unit type.
Product Number
TRTOOL
Rating Plug Removal Tool
Portable Battery Pack
The hand-held Portable Battery Pack provides an independent power source for
microEntelliGuard, MicroVersaTrip Plus and MicroVersaTrip PM trip units as an
alternative to a test set. The battery pack is used to power up the trip unit to set or
adjust trip set points when the breaker is on the bench or otherwise not powered up.
For microEntelliGuard trip units, the battery pack connects to the trip unit through the
15-pin connector. A battery pack adapter cable is required. For MicroVersaTrip Plus and
MicroVersaTrip PM trip units, the battery pack connects to the trip unit through the
rating plug test jack. The battery pack requires three standard 9 Vdc alkaline batteries
(not included).
Description Product Number Portable Battery Pack
Portable Battery Pack TVPBP
Battery Pack Adapter Cable TVPBPACC
(required for microEntelliGuard trip units)

Portable Test Set


The portable, battery-powered test kit provides self-tests and functional trip/no trip tests.
It also provides defeat of the ground fault function and can be used in conjuntion with
high current test equipment. Interface is via a plug on the front of the trip unit and test
can be conducted with the breaker in service. Test kits use either 120 Vac power source Battery Pack Adapter Cable
or internal batteries (not included).
Description Trip Unit Type Product Number
MicroVersaTrip only TVRMS21
Portable Test Set
microEntelliGuard only GTUTK20
1Not for use with MicroVersaTrip 4- or 9-Function trip units

Reduced Energy Let-Through (RELT) Switch Kit


The RELT switch kit is used to switch the trip unit into Reduced Energy Let-Through Mode.
The kit contains a three position selector switch, contact blocks, a lockable switch cover,
RELT warning label, and an 8-ft wiring harness.
Description Product Number
RELT Switch Kit GTURSK

Portable Test Kit

6-66 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Molded Case Circuit Breakers Section 6
Internal Accessories
Spectra RMS Circuit Breakers

Universal Field-Installable Internal Accessories


All Spectra RMS circuit breakers from the SE150 through the SK1200, including
instantaneous-trip Mag Break motor circuit protectors and molded case switches,
use the same UL listed, field-installable internal accessories that do not require cover
removal to install.

Accessory Mounting
All accessories mount in pouches accessible from a front cover. All breakers have a
left-side pouch and right-side pouch. The following combinations may be installed:

Left-Side Poucheither shunt trip or undervoltage release plus bell alarm. Left Side Pouch Right Side Pouch
Right-Side Pouchauxiliary switch (single or double pole).

Auxiliary Switch
Auxiliary switches provide remote indication of whether the circuit breaker main
contacts are opened or closed via open or closed SPDT switch elements.
Switch Number of Auxiliary Switch
Rating Switch Elements Product Number
5A @240 Vac/ 1 form C SAUXPAB1
0.5A @ 125 Vdc 2 form C SAUXPAB2
Gold-Plated Contacts 1 form C SAUXGAB1
0.5A @ 30V 2 form C SAUXGAB2
One each 2 form C SAUXGPAB2
of above types

Auxiliary Switch
Red
All accessory contacts shown
White with the circuit breaker in
Brown/white tripped position.

Spectra RMS Test Set


Provides basic trip-test functionality for all SPectra RMS, (SE, SF, SG, SK) Circuit Breakers
not equipped with LCD Displays. Test Kit plus Test Rating Plug are required.
Product
Description Number
Spectra RMS Trip Tester SPTK1
Spectra RMS Test Rating Plug SRPT1

Shunt Trip Trip Test Kit Test Rating Plug

For remote tripping of breaker, use with momentary close contact. Not recommended for
use with latching relay contact since electronics in shunt trip will pulse power to the coil
if continuously energized, and breaker shunt tripping upon reclosure will be delayed 1-2
seconds at rated control voltage. (A short-circuit trip would be instantaneous.)
If maintained (latching relay) contact must be used and delayed shunt tripping is not
acceptable, use small bell alarm in series with control power for SE150 and SF250 frames
and auxiliary switch for SG600 and SK1200 breakers.
These devices are suitable for use with ground fault sensing and relaying equipment.
Maximum VA is 75. AC devices are UL listed for 50-60 Hz.

Voltage Current (mA) Product


ac dc Inrush Cont Number
120 125 500 6.0 SAST1
Shunt Trip
240 250 400 5.0 SAST2
12 1000 800 SAST51
24 24 300 10.0 SAST3
48 48 300 10.0 SAST4
1Not suitable for use with ground fault sensing and relaying equipment.
Note: UL listed at 200,000 AIC without internal accessories, 100,000 AIC with internally mounted accessories.
Black
All accessory contacts shown
with the circuit breaker in
Black tripped position.

Rev. 11/13 www.geindustrial.com BuyLog Catalog 6-67


Data subject to change
without notice
Molded Case Circuit Breakers Section 6
Internal Accessories
Spectra RMS Circuit Breakers

Undervoltage Release
The undervoltage release provides automatic circuit breaker tripping when there is a
power loss or major dip (to 35%-70% of rated voltage) in accessory control voltage. AC
devices are UL listed for 50-60 Hz. Product number SAUV1 may be used with time delay
unit SPUVTD (List Price $430.00, GO-245B) (delay 0.1 to 1.0 seconds), 120 Vac input,
125 Vdc output.

Voltage Peak Current Product


ac dc (mA) Number
120 125 200 SAUV1
240 250 200 SAUV2
24 24 100 SAUV3
48 48 100 SAUV4
Undervoltage Release
120 125 SPUVTD

Blue All accessory contacts shown


with the circuit breaker in
Blue tripped position.

Bell Alarm Switch


The bell alarm switch provides remote indication of whether the circuit breaker has been
tripped via open or closed SPDT switch elements, but remains unchanged during "On/Off"
circuit breaker operation and during operation by the "Push-to-Trip" button.
Switch Number of Product
Rating Switch Elements Number
5A @ 240 Vac/
1 form C SABAP1
0.5A @ 125 Vdc
Gold-Plated Contacts
Bell Alarm Switch
1 form C SABAG1
0.5A @30V

Note: UL listed at 200,000 AIC without internal accessories, 100,000 AIC with internally mounted accessories.

Purple
Yellow All accessory contacts shown
with the circuit breaker in
Brown tripped position.

Actuator
All Spectra circuit breakers are supplied with an actuator installed in the left-side pouch.
The actuator is removed when installing either a shunt trip or undervoltage release.
Description Product Number
Replacement Actuator SACTUATOR

6-68 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Molded Case Circuit Breakers Section 6
Record Plus FB 100
Reference Publications
Available for download from www.geindustrial.com/publibrary
FB Breaker
1 Breaker Frame Rating Installation Instructions DEH-41073
Fact sheet DET-406
2 Product Description FB Breaker Accessories
3 Standards & Ratings Bell Alarm & Aux. Switch DEH-40324
2 4 Shunt Trip & UVR DEH-40363
1 Interrupting Ratings
Padlock Device DEH-40521
3 5 Lug Data & Torque Info Lug Kits DEH-40532
6 Product Number Panelboards
4 A-Series AD Plus Catalog/Selection Guide DEP-134
7 Push to Trip
A-Series AD Plus Fact Sheet DET-397
5 Spectra Power Panel - Plug-in Kits DEH-41123
6 Spectra Power Panel - Bolt-on Kits DEH-41124
Spectra Power Panel - Filler Plates DEH-41125
7 Outline Drawings
FB 1 pole 10091632SH1
FB 2 pole 10091636SH1
FB 3 pole 10091641SH1
Series Ratings DET-008

Trip Curves
Trip Unit Rated Current (A) Trip Curve
15 DES-013
FB Breaker Markings
20 DES-014
cULus UL File E-11592 25 DES-015
HACR 15 to 100A 1, 2, 3 Pole 30 DES-016
HID 15 to 50A 1, 2, 3 Pole 35 DES-017
NAVAL 15 to 100A 1, 2, 3 Pole 40 DES-018
Cu/Al 60/75C 15 to 100A 1, 2, 3 Pole 45 DES-019
Current Limiting 15 to 100A 1, 2, 3 Pole 50 DES-020
60 DES-021
FB breakers are NOT marked LINE/LOAD and can be reverse fed. 70 DES-022
80 DES-023
90 DES-024
100 DES-025
Peak Current Curves DES-030
Peak I2t Curve DES-031
Interrupting Ratings
UL Listed Interrupting Ratings -
rms Symmetrical Amperes (in Thousands) AC Voltage
Type Ampere Rating Max AC Voltage No. Poles 240 277 347 480 600/347
1 35 35 22
FBV 15-100 600/347VAC 2 65 35 22
3 65 35 22
1 65 65 25
FBN 15-100 600/347VAC 2 150 65 25
3 150 65 25
1 100 100 35
FBH 15-100 600/347VAC 2 200 100 35
3 200 100 35
1 100 150 42
FBL 15-100 600/347VAC 2 200 150 42
3 200 150 42

Product Number Structure


F B N 3 6 TE 050 R

Frame Rating Interruption Voltage Rated


1
Family (Amperes) Rating (480V) Poles Rating Type Current (A) Connection
F = Record B = 100 V = 35kA 1 = 1 pole 6 = 600/347 TE = Fixed 015 100 R= Standard,
Plus N = 65kA 2 = 2 poles Thermal No Lugs
H = 100kA 3 = 3 poles Magnetic R2 = Load Lugs Only
L = 150 kA RV = A-Series AD
Plus Lighting
Panel (Includes
Load Lugs
1 and panel
Available ampere ratings: 15, 20, 25, 30, 35, 40, 45, 50, 60, 70, 80, 90, 100.
connections)

Rev. 11/13 www.geindustrial.com BuyLog Catalog 6-69


Data subject to change
without notice
Molded Case Circuit Breakers Section 6
Record Plus FB 100

1-Pole Record Plus FB 100 Breakers IC @ 600/347 Vac


Rated 35kA 65kA 100kA 150kA
Current (A) Product No. Product No. Product No. Product No. Connection
FBV16TE015R FBN16TE015R FBH16TE015R FBL16TE015R No Lugs
FBV16TE015R2 FBN16TE015R2 FBH16TE015R2 FBL16TE015R2 Load Lugs Only
15
FBV16TE015RV FBN16TE015RV FBH16TE015RV FBL16TE015RV Load Lugs and
Panel Connections
FBV16TE020R FBN16TE020R FBH16TE020R FBL16TE020R No Lugs
FBV16TE020R2 FBN16TE020R2 FBH16TE020R2 FBL16TE020R2 Load Lugs Only
20
FBV16TE020RV FBN16TE020RV FBH16TE020RV FBL16TE020RV Load Lugs and
Panel Connections
FBV16TE025R FBN16TE025R FBH16TE025R FBL16TE025R No Lugs
FBV16TE025R2 FBN16TE025R2 FBH16TE025R2 FBL16TE025R2 Load Lugs Only
25
FBV16TE025RV FBN16TE025RV FBH16TE025RV FBL16TE025RV Load Lugs and
Panel Connections
FBV16TE030R FBN16TE030R FBH16TE030R FBL16TE030R No Lugs
FBV16TE030R2 FBN16TE030R2 FBH16TE030R2 FBL16TE030R2 Load Lugs Only
30
FBV16TE030RV FBN16TE030RV FBH16TE030RV FBL16TE030RV Load Lugs and
Panel Connections
FBV16TE035R FBN16TE035R FBH16TE035R FBL16TE035R No Lugs
FBV16TE035R2 FBN16TE035R2 FBH16TE035R2 FBL16TE035R2 Load Lugs Only
35
FBV16TE035RV FBN16TE035RV FBH16TE035RV FBL16TE035RV Load Lugs and
Panel Connections
FBV16TE040R FBN16TE040R FBH16TE040R FBL16TE040R No Lugs
FBV16TE040R2 FBN16TE040R2 FBH16TE040R2 FBL16TE040R2 Load Lugs Only
40
FBV16TE040RV FBN16TE040RV FBH16TE040RV FBL16TE040RV Load Lugs and
Panel Connections
FBV16TE045R FBN16TE045R FBH16TE045R FBL16TE045R No Lugs
FBV16TE045R2 FBN16TE045R2 FBH16TE045R2 FBL16TE045R2 Load Lugs Only
45
FBV16TE045RV FBN16TE045RV FBH16TE045RV FBL16TE045RV Load Lugs and
Panel Connections
FBV16TE050R FBN16TE050R FBH16TE050R FBL16TE050R No Lugs
FBV16TE050R2 FBN16TE050R2 FBH16TE050R2 FBL16TE050R2 Load Lugs Only
50
FBV16TE050RV FBN16TE050RV FBH16TE050RV FBL16TE050RV Load Lugs and
Panel Connections
FBV16TE060R FBN16TE060R FBH16TE060R FBL16TE060R No Lugs
FBV16TE060R2 FBN16TE060R2 FBH16TE060R2 FBL16TE060R2 Load Lugs Only
60
FBV16TE060RV FBN16TE060RV FBH16TE060RV FBL16TE060RV Load Lugs and
Panel Connections
FBV16TE070R FBN16TE070R FBH16TE070R FBL16TE070R No Lugs
FBV16TE070R2 FBN16TE070R2 FBH16TE070R2 FBL16TE070R2 Load Lugs Only
70
FBV16TE070RV FBN16TE070RV FBH16TE070RV FBL16TE070RV Load Lugs and
Panel Connections
FBV16TE080R FBN16TE080R FBH16TE080R FBL16TE080R No Lugs
FBV16TE080R2 FBN16TE080R2 FBH16TE080R2 FBL16TE080R2 Load Lugs Only
80
FBV16TE080RV FBN16TE080RV FBH16TE080RV FBL16TE080RV Load Lugs and
Panel Connections
FBV16TE090R FBN16TE090R FBH16TE090R FBL16TE090R No Lugs
FBV16TE090R2 FBN16TE090R2 FBH16TE090R2 FBL16TE090R2 Load Lugs Only
90
FBV16TE090RV FBN16TE090RV FBH16TE090RV FBL16TE090RV Load Lugs and
Panel Connections
FBV16TE100R FBN16TE100R FBH16TE100R FBL16TE100R No Lugs
FBV16TE100R2 FBN16TE100R2 FBH16TE100R2 FBL16TE100R2 Load Lugs Only
100
FBV16TE100RV FBN16TE100RV FBH16TE100RV FBL16TE100RV Load Lugs and
Panel Connections

6-70 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Molded Case Circuit Breakers Section 6
Record Plus FB 100

2-Pole Record Plus FB 100 Breakers IC @ 600/347 Vac


Rated 35kA 65kA 100kA 150kA
Current (A) Product No. Product No. Product No. Product No. Connection
FBV26TE015R FBN26TE015R FBH26TE015R FBL26TE015R No Lugs
FBV26TE015R2 FBN26TE015R2 FBH26TE015R2 FBL26TE015R2 Load Lugs Only
15
FBV26TE015RV FBN26TE015RV FBH26TE015RV FBL26TE015RV Load Lugs and
Panel Connections
FBV26TE020R FBN26TE020R FBH26TE020R FBL26TE020R No Lugs
FBV26TE020R2 FBN26TE020R2 FBH26TE020R2 FBL26TE020R2 Load Lugs Only
20
FBV26TE020RV FBN26TE020RV FBH26TE020RV FBL26TE020RV Load Lugs and
Panel Connections
FBV26TE025R FBN26TE025R FBH26TE025R FBL26TE025R No Lugs
FBV26TE025R2 FBN26TE025R2 FBH26TE025R2 FBL26TE025R2 Load Lugs Only
25
FBV26TE025RV FBN26TE025RV FBH26TE025RV FBL26TE025RV Load Lugs and
Panel Connections
FBV26TE030R FBN26TE030R FBH26TE030R FBL26TE030R No Lugs
FBV26TE030R2 FBN26TE030R2 FBH26TE030R2 FBL26TE030R2 Load Lugs Only
30
FBV26TE030RV FBN26TE030RV FBH26TE030RV FBL26TE030RV Load Lugs and
Panel Connections
FBV26TE035R FBN26TE035R FBH26TE035R FBL26TE035R No Lugs
FBV26TE035R2 FBN26TE035R2 FBH26TE035R2 FBL26TE035R2 Load Lugs Only
35
FBV26TE035RV FBN26TE035RV FBH26TE035RV FBL26TE035RV Load Lugs and
Panel Connections
FBV26TE040R FBN26TE040R FBH26TE040R FBL26TE040R No Lugs
FBV26TE040R2 FBN26TE040R2 FBH26TE040R2 FBL26TE040R2 Load Lugs Only
40
FBV26TE040RV FBN26TE040RV FBH26TE040RV FBL26TE040RV Load Lugs and
Panel Connections
FBV26TE045R FBN26TE045R FBH26TE045R FBL26TE045R No Lugs
FBV26TE045R2 FBN26TE045R2 FBH26TE045R2 FBL26TE045R2 Load Lugs Only
45
FBV26TE045RV FBN26TE045RV FBH26TE045RV FBL26TE045RV Load Lugs and
Panel Connections
FBV26TE050R FBN26TE050R FBH26TE050R FBL26TE050R No Lugs
FBV26TE050R2 FBN26TE050R2 FBH26TE050R2 FBL26TE050R2 Load Lugs Only
50
FBV26TE050RV FBN26TE050RV FBH26TE050RV FBL26TE050RV Load Lugs and
Panel Connections
FBV26TE060R FBN26TE060R FBH26TE060R FBL26TE060R No Lugs
FBV26TE060R2 FBN26TE060R2 FBH26TE060R2 FBL26TE060R2 Load Lugs Only
60
FBV26TE060RV FBN26TE060RV FBH26TE060RV FBL26TE060RV Load Lugs and
Panel Connections
FBV26TE070R FBN26TE070R FBH26TE070R FBL26TE070R No Lugs
FBV26TE070R2 FBN26TE070R2 FBH26TE070R2 FBL26TE070R2 Load Lugs Only
70
FBV26TE070RV FBN26TE070RV FBH26TE070RV FBL26TE070RV Load Lugs and
Panel Connections
FBV26TE080R FBN26TE080R FBH26TE080R FBL26TE080R No Lugs
FBV26TE080R2 FBN26TE080R2 FBH26TE080R2 FBL26TE080R2 Load Lugs Only
80
FBV26TE080RV FBN26TE080RV FBH26TE080RV FBL26TE080RV Load Lugs and
Panel Connections
FBV26TE090R FBN26TE090R FBH26TE090R FBL26TE090R No Lugs
FBV26TE090R2 FBN26TE090R2 FBH26TE090R2 FBL26TE090R2 Load Lugs Only
90
FBV26TE090RV FBN26TE090RV FBH26TE090RV FBL26TE090RV Load Lugs and
Panel Connections
FBV26TE100R FBN26TE100R FBH26TE100R FBL26TE100R No Lugs
FBV26TE100R2 FBN26TE100R2 FBH26TE100R2 FBL26TE100R2 Load Lugs Only
100
FBV26TE100RV FBN26TE100RV FBH26TE100RV FBL26TE100RV Load Lugs and
Panel Connections

Rev. 11/13 www.geindustrial.com BuyLog Catalog 6-71


Data subject to change
without notice
Molded Case Circuit Breakers Section 6
Record Plus FB 100

3-Pole Record Plus FB 100 Breakers IC @ 600/347 Vac


Rated 35kA 65kA 100kA 150kA
Current (A) Product No. Product No Product No Product No Connection
FBV36TE015R FBN36TE015R FBH36TE015R FBL36TE015R No Lugs
FBV36TE015R2 FBN36TE015R2 FBH36TE015R2 FBL36TE015R2 Load Lugs Only
15
FBV36TE015RV FBN36TE015RV FBH36TE015RV FBL36TE015RV Load Lugs and
Panel Connections
FBV36TE020R FBN36TE020R FBH36TE020R FBL36TE020R No Lugs
FBV36TE020R2 FBN36TE020R2 FBH36TE020R2 FBL36TE020R2 Load Lugs Only
20
FBV36TE020RV FBN36TE020RV FBH36TE020RV FBL36TE020RV Load Lugs and
Panel Connections
FBV36TE025R FBN36TE025R FBH36TE025R FBL36TE025R No Lugs
FBV36TE025R2 FBN36TE025R2 FBH36TE025R2 FBL36TE025R2 Load Lugs Only
25
FBV36TE025RV FBN36TE025RV FBH36TE025RV FBL36TE025RV Load Lugs and
Panel Connections
FBV36TE030R FBN36TE030R FBH36TE030R FBL36TE030R No Lugs
FBV36TE030R2 FBN36TE030R2 FBH36TE030R2 FBL36TE030R2 Load Lugs Only
30
FBV36TE030RV FBN36TE030RV FBH36TE030RV FBL36TE030RV Load Lugs and
Panel Connections
FBV36TE035R FBN36TE035R FBH36TE035R FBL36TE035R No Lugs
FBV36TE035R2 FBN36TE035R2 FBH36TE035R2 FBL36TE035R2 Load Lugs Only
35
FBV36TE035RV FBN36TE035RV FBH36TE035RV FBL36TE035RV Load Lugs and
Panel Connections
FBV36TE040R FBN36TE040R FBH36TE040R FBL36TE040R No Lugs
FBV36TE040R2 FBN36TE040R2 FBH36TE040R2 FBL36TE040R2 Load Lugs Only
40
FBV36TE040RV FBN36TE040RV FBH36TE040RV FBL36TE040RV Load Lugs and
Panel Connections
FBV36TE045R FBN36TE045R FBH36TE045R FBL36TE045R No Lugs
FBV36TE045R2 FBN36TE045R2 FBH36TE045R2 FBL36TE045R2 Load Lugs Only
45
FBV36TE045RV FBN36TE045RV FBH36TE045RV FBL36TE045RV Load Lugs and
Panel Connections
FBV36TE050R FBN36TE050R FBH36TE050R FBL36TE050R No Lugs
FBV36TE050R2 FBN36TE050R2 FBH36TE050R2 FBL36TE050R2 Load Lugs Only
50
FBV36TE050RV FBN36TE050RV FBH36TE050RV FBL36TE050RV Load Lugs and
Panel Connections
FBV36TE060R FBN36TE060R FBH36TE060R FBL36TE060R No Lugs
FBV36TE060R2 FBN36TE060R2 FBH36TE060R2 FBL36TE060R2 Load Lugs Only
60
FBV36TE060RV FBN36TE060RV FBH36TE060RV FBL36TE060RV Load Lugs and
Panel Connections
FBV36TE070R FBN36TE070R FBH36TE070R FBL36TE070R No Lugs
FBV36TE070R2 FBN36TE070R2 FBH36TE070R2 FBL36TE070R2 Load Lugs Only
70
FBV36TE070RV FBN36TE070RV FBH36TE070RV FBL36TE070RV Load Lugs and
Panel Connections
FBV36TE080R FBN36TE080R FBH36TE080R FBL36TE080R No Lugs
FBV36TE080R2 FBN36TE080R2 FBH36TE080R2 FBL36TE080R2 Load Lugs Only
80
FBV36TE080RV FBN36TE080RV FBH36TE080RV FBL36TE080RV Load Lugs and
Panel Connections
FBV36TE090R FBN36TE090R FBH36TE090R FBL36TE090R No Lugs
FBV36TE090R2 FBN36TE090R2 FBH36TE090R2 FBL36TE090R2 Load Lugs Only
90
FBV36TE090RV FBN36TE090RV FBH36TE090RV FBL36TE090RV Load Lugs and
Panel Connections
FBV36TE100R FBN36TE100R FBH36TE100R FBL36TE100R No Lugs
FBV36TE100R2 FBN36TE100R2 FBH36TE100R2 FBL36TE100R2 Load Lugs Only
100
FBV36TE100RV FBN36TE100RV FBH36TE100RV FBL36TE100RV Load Lugs and
Panel Connections

6-72 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Molded Case Circuit Breakers Section 6
Record Plus FB 100
Internal Accessories

Releases Shunt Trip and Undervoltage


Shunt Trip Undervoltage Release
Voltage Product No. Product No.
12 VDC FASHTBW
24 VAC/DC FASHTDW FAUVRDW
48 VAC/DC FASHTFW FAUVRFW
110-130 VAC/110-125 VDC FASHTJW FAUVRJW
120 VAC FASHTKW
220/240 VAC, 250 VDC FASHTNW FAUVRNW
277 VAC FASHT7W FAUVR7W
400/480 VAC FASHTUW FAUVRUW

UL Listed for field installation. Accessories are prewired from the factory with 36 inch long leads
(#18 AWG). Shunt trip wire leads are black and UVR wire leads are blue.

Bell Alarm
Contact
Configuration Contacts Contact Rating Wire leads Product No.
1 NO (Form A) Standard 5A @ 277 VAC, 0.3A @ 125 VDC #16 AWG FABAM10W
1 NC (Form B) Standard 5A @ 277 VAC, 0.3A @ 125 VDC #16 AWG FABAM01W

UL Listed for field installation. Accessories are prewired from the factory with 36 inch long leads. Reference
instruction sheet DEH-40324 for wire lead colors.

Auxiliary Switches
Contact Left Mount Right Mount
Configuration Contacts Contact Rating Wire leads Product No. Product No.
1 NO (Form A) Standard 5A @ 277 VAC, #16 AWG FAS10LW FAS10RW
0.3A @ 125 VDC
1 NC (Form B) Standard 5A @ 277 VAC, #16 AWG FAS01LW FAS01RW
0.3A @ 125 VDC

UL Listed for field installation. Accessories are prewired from the factory with 36 inch long leads. Reference
instruction sheet DEH-40324 for wire lead colors.

Mounting Locations and Limitations


Accessory Installation Shunt Trip or
Bell Alarm
Undervoltage
Accessory Mounting Pocket Location 1 Pole 2 Pole 3 Pole Switch
Release
Shunt Trip or Undervoltage Release 0 1 1
Aux. Switch - Left Mount 0 0 1
Aux. Switch - Right Mount 0 0 1
Bell Alarm 0 0 1 Auxiliary
Switches
Maximum Number of Internal Accessories 0 1 4
That Can Be Installed
2 pole 3 pole

Mounting Locations

Rev. 11/13 www.geindustrial.com BuyLog Catalog 6-73


Data subject to change
without notice
Molded Case Circuit Breakers Section 6
Record Plus FB 100
External Accessories

Padlocking Devices
Description Product No.
Padlock Fixed Toggle FB1PF
Padlock EUSERC Toggle FB1PE

Lugs and Lug Kits


Single Lug Lug Kit
Amp Range Wire Range Strip Length Product No. Product No. (Set of 3)
15-20A 14-10 Cu/Al .40-.50 FCAL12 FCALK12
25-60A 10-4 Cu/Al .40-.50 FCAL13 FCALK13
70-100A 4-1/0 Cu/Al .40-.50 FCAL14 FCALK14

Lug Tightening Torque


Wire Size Torque
#10 AWG 35 in-lb
#8 AWG 40 in-lb
#6-#4 AWG 45 in-lb
#3 AWG - 1/0 50 in-lb

Dimensions in. (mm)

FB 100 Dimensions
Poles A B C D E F G1 G2 H
1 3.88 (98.6) 3.28 (83.3) 1.06 (26.9) 1.36 (34.5) N/A N/A 5.11 (129.8) 5.01 (127.3) 6.45 (163.8)
2 3.88 (98.6) 3.28 (83.3) 1.06 (26.9) 2.74 (69.6) 0.69 (17.5) 1.38 (35.1) 5.11 (129.8) 5.01 (127.3) 6.45 (163.8)
3 3.88 (98.6) 3.28 (83.3) 1.06 (26.9) 4.11 (104.4) 1.38 (35.1) 1.38 (35.1) 5.11 (129.8) 5.01 (127.3) 6.45 (163.8)

"D" "A"
"D" "E" "E" "B"
"D" "F"
"E" "F" "C"

"G2" "G2" "G2"

"G1"
"G1" "G1"

"H" "H" "H"

6-74 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Molded Case Circuit Breakers Section 6
Record Plus FC 100

Reference Publications
Available for download from www.geindustrial.com/publibrary
1 Breaker Frame Rating FC Breaker
2 Rated Voltage Installation Instructions DEH-40463
3 FC Breaker Accessories
Breaker Frame Bell Alarm & Aux. Switch DEH-40324
4 Enclosed Rating Shunt Trip & Undervoltage Release DEH-40363
4
1 3 5 Product Description Lug Kits DEH-40532
5 Outline Drawings
2 6 Standards
6 FC 2-3 pole 10085772SH1
7 Interruption Capacity Series Ratings DET-008
7
Product Number

Trip Curves
Trip Unit Rated Current (A) Trip Curve
15 DES-013
20 DES-014
25 DES-015
30 DES-016
35 DES-017
40 DES-018
Main Standards 45 DES-019
50 DES-020
UL 489 60 DES-021
IEC 947 and associated EN Sections 70 DES-022
80 DES-023
90 DES-024
FC Breaker Markings 100 DES-025
Peak Current Curves DES-030
cULus UL File E-11592
Peak I2t Curve DES-031
HID 15-50A
HACR 15 to 100A
Cu/Al 60/75C 15 to 100A
Current Limiting 15 to 100A

FC 100 Amp Frame Overview

Interrupting Ratings Federal Spec C/B Class WC-375B


UL Listed Interrupting Ratings - IEC Listed Interrupting Ratings,
rms Symmetrical Amperes (in Thousands) Icu, Amperes (in Thousands)
AC Voltage DC Voltage AC Voltage DC Voltage
Type Ampere Rating No. Poles Max AC/DC Voltage 240 480 600/347 250 (2p) 500 (3p) 220-240 400-415 500 250 (2p) 500 (3p)
FCS 15-100 2,3 600VAC, 500VDC 42 25 18 22 30 36 22 14 22 30
FCV 15-100 2,3 600VAC, 500VDC 65 35 22 25 35 50 30 18 25 35
FCN 15-100 2,3 600VAC, 500VDC 150 65 25 30 42 85 50 22 30 42
FCH 15-100 2,3 600VAC, 500VDC 200 100 35 42 65 100 80 36 42 65
FCL 15-100 2,3 600VAC, 500VDC 200 150 42 65 80 200 150 50 65 80

Product Number Structure


F C N 3 6 TE 050 R

Frame Rating Interruption Voltage Rated


Family (Amperes) Rating (480V) Poles Rating Type Current (A) Connection
F = Record C = 100 S = 25kA 3 = 3 poles 6 = 600V TE = Fixed Thermal 015 100 R = Standard,
Plus V = 35kA 32 = 2 poles Magnetic No Lugs
N = 65kA in 3-pole R1 = Line and Load
H = 100 kA envelope Lugs Installed
L = 150kA R2 = Load Lugs
Only
Selection

Record Plus, Non-Automatic Circuit Breaker (Molded Case Switch), 600 VAC
2-Pole 3-Pole Lug Kit (3 per kit)
Ampere Rating Product No. Product No. Product No.
60 FCY206F060R FCY306F060R FCALK13
100 FCY206F100R FCY306F100R FCALK14

Rev. 11/13 www.geindustrial.com BuyLog Catalog 6-75


Data subject to change
without notice
Molded Case Circuit Breakers Section 6
Record Plus FC 100

2-Pole Record Plus FC 100 Breakers IC @ 480 Vac


Rated 25kA 35kA 65kA 100kA 150kA
Current (A) Product No. Product No. Product No. Product No. Product No. Connection
FCS326TE015R FCV326TE015R FCN326TE015R FCH326TE015R FCL326TE015R No Lugs
15 FCS326TE015R1 FCV326TE015R1 FCN326TE015R1 FCH326TE015R1 FCL326TE015R1 Line and Load
Lugs Installed
FCS326TE015R2 FCV326TE015R2 FCN326TE015R2 FCH326TE015R2 FCL326TE015R2 Load Lugs Only
FCS326TE020R FCV326TE020R FCN326TE020R FCH326TE020R FCL326TE020R No Lugs
20 FCS326TE020R1 FCV326TE020R1 FCN326TE020R1 FCH326TE020R1 FCL326TE020R Line and Load
Lugs Installed
FCS326TE020R2 FCV326TE020R2 FCN326TE020R2 FCH326TE020R2 FCL326TE020R2 Load Lugs Only
FCS326TE025R FCV326TE025R FCN326TE025R FCH326TE025R FCL326TE025R No Lugs
FCS326TE025R1 FCV326TE025R1 FCN326TE025R1 FCH326TE025R1 FCL326TE025R1 Line and Load
25
Lugs Installed
FCS326TE025R2 FCV326TE025R2 FCN326TE025R2 FCH326TE025R2 FCL326TE025R2 Load Lugs Only
FCS326TE030R FCV326TE030R FCN326TE030R FCH326TE030R FCL326TE030R No Lugs
FCS326TE030R1 FCV326TE030R1 FCN326TE030R1 FCH326TE030R1 FCL326TE030R1 Line and Load
30
Lugs Installed
FCS326TE030R2 FCV326TE030R2 FCN326TE030R2 FCH326TE030R2 FCL326TE030R2 Load Lugs Only
FCS326TE035R FCV326TE035R FCN326TE035R FCH326TE035R FCL326TE035R No Lugs
FCS326TE035R1 FCV326TE035R1 FCN326TE035R1 FCH326TE035R1 FCL326TE035R1 Line and Load
35
Lugs Installed
FCS326TE035R2 FCV326TE035R2 FCN326TE035R2 FCH326TE035R2 FCL326TE035R2 Load Lugs Only
FCS326TE040R FCV326TE040R FCN326TE040R FCH326TE040R FCL326TE040R No Lugs
FCS326TE040R1 FCV326TE040R1 FCN326TE040R1 FCH326TE040R1 FCL326TE040R1 Line and Load
40
Lugs Installed
FCS326TE040R2 FCV326TE040R2 FCN326TE040R2 FCH326TE040R2 FCL326TE040R2 Load Lugs Only
FCS326TE045R FCV326TE045R FCN326TE045R FCH326TE045R FCL326TE045R No Lugs
FCS326TE045R1 FCV326TE045R1 FCN326TE045R1 FCH326TE045R1 FCL326TE045R1 Line and Load
45
Lugs Installed
FCS326TE045R2 FCV326TE045R2 FCN326TE045R2 FCH326TE045R2 FCL326TE045R2 Load Lugs Only
FCS326TE050R FCV326TE050R FCN326TE050R FCH326TE050R FCL326TE050R No Lugs
FCS326TE050R1 FCV326TE050R1 FCN326TE050R1 FCH326TE050R1 FCL326TE050R1 Line and Load
50
Lugs Installed
FCS326TE050R2 FCV326TE050R2 FCN326TE050R2 FCH326TE050R2 Load Lugs Only
FCS326TE060R FCV326TE060R FCN326TE060R FCH326TE060R FCL326TE060R No Lugs
FCS326TE060R1 FCV326TE060R1 FCN326TE060R1 FCH326TE060R1 FCL326TE060R1 Line and Load
60
Lugs Installed
FCS326TE060R2 FCV326TE060R2 FCN326TE060R2 FCH326TE060R2 FCL326TE060R2 Load Lugs Only
FCS326TE070R FCV326TE070R FCN326TE070R FCH326TE070R FCL326TE070R No Lugs
FCS326TE070R1 FCV326TE070R1 FCN326TE070R1 FCH326TE070R1 FCL326TE070R1 Line and Load
70
Lugs Installed
FCS326TE070R2 FCV326TE070R2 FCN326TE070R2 FCH326TE070R2 FCL326TE070R2 Load Lugs Only
FCS326TE080R FCV326TE080R FCN326TE080R FCH326TE080R FCL326TE080R No Lugs
FCS326TE080R1 FCV326TE080R1 FCN326TE080R1 FCH326TE080R1 FCL326TE080R1 Line and Load
80
Lugs Installed
FCS326TE080R2 FCV326TE080R2 FCN326TE080R2 FCH326TE080R2 FCL326TE080R2 Load Lugs Only
FCS326TE090R FCV326TE090R FCN326TE090R FCH326TE090R FCL326TE090R No Lugs
FCS326TE090R1 FCV326TE090R1 FCN326TE090R1 FCH326TE090R1 FCL326TE090R1 Line and Load
90
Lugs Installed
FCS326TE090R2 FCV326TE090R2 FCN326TE090R2 FCH326TE090R2 FCL326TE090R2 Load Lugs Only
FCS326TE100R FCV326TE100R FCN326TE100R FCH326TE100R FCL326TE100R No Lugs
FCS326TE100R1 FCV326TE100R1 FCN326TE100R1 FCH326TE100R1 FCL326TE100R1 Line and Load
100
Lugs Installed
FCS326TE100R2 FCN326TE100R2 FCH326TE100R2 FCL326TE100R2 Load Lugs Only

6-76 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Molded Case Circuit Breakers Section 6
Record Plus FC 100

3-Pole Record Plus FC 100 Breakers IC @ 480 Vac


Rated 25kA 35kA 65kA 100kA 150kA
Current (A) Product No. Product No. Product No. Product No. Product No. Connection
FCS36TE015R FCV36TE015R FCN36TE015R FCH36TE015R FCL36TE015R No Lugs
15 FCS36TE015R1 FCV36TE015R1 FCN36TE015R1 FCH36TE015R1 FCL36TE015R1 Line and Load
Lugs Installed
FCS36TE015R2 FCV36TE015R2 FCN36TE015R2 FCH36TE015R2 FCL36TE015R2 Load Lugs Only
FCS36TE020R FCV36TE020R FCN36TE020R FCH36TE020R FCL36TE020R No Lugs
20 FCS36TE020R1 FCV36TE020R1 FCN36TE020R1 FCH36TE020R1 FCL36TE020R1 Line and Load
Lugs Installed
FCS36TE020R2 FCV36TE020R2 FCN36TE020R2 FCH36TE020R2 FCL36TE020R2 Load Lugs Only
FCS36TE025R FCV36TE025R FCN36TE025R FCH36TE025R FCL36TE025R No Lugs
FCS36TE025R1 FCV36TE025R1 FCN36TE025R1 FCH36TE025R1 FCL36TE025R1 Line and Load
25
Lugs Installed
FCS36TE025R2 FCV36TE025R2 FCN36TE025R2 FCH36TE025R2 FCL36TE025R2 Load Lugs Only
FCS36TE030R FCV36TE030R FCN36TE030R FCH36TE030R FCL36TE030R No Lugs
FCS36TE030R1 FCV36TE030R1 FCN36TE030R1 FCH36TE030R1 FCL36TE030R1 Line and Load
30
Lugs Installed
FCS36TE030R2 FCV36TE030R2 FCN36TE030R2 FCH36TE030R2 FCL36TE030R2 Load Lugs Only
FCS36TE035R FCV36TE035R FCN36TE035R FCH36TE035R FCL36TE035R No Lugs
FCS36TE035R1 FCV36TE035R1 FCN36TE035R1 FCH36TE035R1 FCL36TE035R1 Line and Load
35
Lugs Installed
FCS36TE035R2 FCV36TE035R2 FCN36TE035R2 FCH36TE035R2 FCL36TE035R2 Load Lugs Only
FCS36TE040R FCV36TE040R FCN36TE040R FCH36TE040R FCL36TE040R No Lugs
FCS36TE040R1 FCV36TE040R1 FCN36TE040R1 FCH36TE040R1 FCL36TE040R1 Line and Load
40
Lugs Installed
FCS36TE040R2 FCV36TE040R2 FCN36TE040R2 FCH36TE040R2 FCL36TE040R2 Load Lugs Only
FCS36TE045R FCV36TE045R FCN36TE045R FCH36TE045R FCL36TE045R No Lugs
FCS36TE045R1 FCV36TE045R1 FCN36TE045R1 FCH36TE045R1 FCL36TE045R1 Line and Load
45
Lugs Installed
FCS36TE045R2 FCV36TE045R2 FCN36TE045R2 FCH36TE045R2 FCL36TE045R2 Load Lugs Only
FCS36TE050 FCV36TE050R FCN36TE050R FCH36TE050R FCL36TE050R No Lugs
FCS36TE050R1 FCV36TE050R1 FCN36TE050R1 FCH36TE050R1 FCL36TE050R1 Line and Load
50
Lugs Installed
FCS36TE050R2 FCV36TE050R2 FCN36TE050R2 FCH36TE050R2 FCL36TE050R2 Load Lugs Only
FCS36TE060R FCV36TE060R FCN36TE060R FCH36TE060R FCL36TE060R No Lugs
FCS36TE060R1 FCV36TE060R1 FCN36TE060R1 FCH36TE060R1 FCL36TE060R1 Line and Load
60
Lugs Installed
FCS36TE060R2 FCV36TE060R2 FCN36TE060R2 FCH36TE060R2 FCL36TE060R2 Load Lugs Only
FCS36TE070R FCV36TE070R FCN36TE070R FCH36TE070R FCL36TE070R No Lugs
FCS36TE070R1 FCV36TE070R1 FCN36TE070R1 FCH36TE070R1 FCL36TE070R1 Line and Load
70
Lugs Installed
FCS36TE070R2 FCV36TE070R2 FCN36TE070R2 FCH36TE070R2 FCL36TE070R2 Load Lugs Only
FCS36TE080R FCV36TE080R FCN36TE080R FCH36TE080R FCL36TE080R No Lugs
FCS36TE080R1 FCV36TE080R1 FCN36TE080R1 FCH36TE080R1 FCL36TE080R1 Line and Load
80
Lugs Installed
FCS36TE080R2 FCV36TE080R2 FCN36TE080R2 FCH36TE080R2 FCL36TE080R2 Load Lugs Only
FCS36TE090R FCV36TE090R FCN36TE090R FCH36TE090R FCL36TE090R No Lugs
FCS36TE090R1 FCV36TE090R1 FCN36TE090R1 FCH36TE090R1 FCL36TE090R1 Line and Load
90
Lugs Installed
FCS36TE090R2 FCV36TE090R2 FCN36TE090R2 FCH36TE090R2 FCL36TE090R2 Load Lugs Only
FCS36TE100R FCV36TE100R FCN36TE100R FCH36TE100R FCL36TE100R No Lugs
FCS36TE100R1 FCV36TE100R1 FCN36TE100R1 FCH36TE100R1 FCL36TE100R1 Line and Load
100
Lugs Installed
FCS36TE100R2 FCV36TE100R2 FCN36TE100R2 FCH36TE100R2 FCL36TE100R2 Load Lugs Only

Rev. 11/13 www.geindustrial.com BuyLog Catalog 6-77


Data subject to change
without notice
Molded Case Circuit Breakers Section 6
Record Plus FC 100
Internal Accessories (supplied with leads attached)

Contacts Auxiliary and Bell Alarm (Rated 5A @240VAC, 0.5A @125VDC)


Normally Open Normally Closed
Accessory Product No. Product No.
Aux. Switch Right Mounted FAS10RW FAS01RW
Aux. Switch Left Mounted FAS10LW FAS01LW Auxiliary Switch/Bell Alarm Mechanism
Bell Alarm Mechanism FABAM10W FABAM01W

Releases Shunt Trip and Undervoltage


Shunt Trip Undervoltage Release
Rating (Inrush Rating (Inrush
Voltage Power Consumption) Product No. Power Consumption) Product No.
12 VDC 200 mA / 2.4W FASHTBW
24 VAC/DC 100 mA / 3.6W FASHTDW 50 mA / 1.2W FAUVRDW
48 VAC/DC 60 mA / 2.88W FASHTFW 20 mA / 0.96W FAUVRFW Shunt Trip/Undervoltage Release
120 VAC 40 mA / 4.8W FASHTKW
110/130 VAC/DC 40 mA / 4.8W FASHTJW 15 mA / 1.8W FAUVRJW
220/240 VAC, 250 VDC 20 mA / 4.6W FASHTNW 15 mA / 3.45W FAUVRNW
Shunt Trip or
277 VAC 11 mA / 3.0W FASHT7W 15 mA / 4.0W FAUVR7W Bell Alarm
Undervoltage
Switch
400/480 VAC 20 mA / 8.4W FASHTUW 15 mA / 6.3W FAUVRUW Release

Mounting Locations and Limitations Auxiliary


Switches
Accessory Installation
Accessory Mounting Pocket Location 2 Pole 3 Pole
2- or 3 pole
Shunt Trip or Undervoltage Release 1 1
Aux. Switch - Left Mount 1 1 Mounting Locations
Aux. Switch - Right Mount 1 1
Bell Alarm 1 1
Maximum Number of Internal Accessories That Can Be Installed 4 4

External Accessories
Electrical Operator Motor Drives,
Front Mounted Padlocking Devices
Motor Operator
Voltage Product No.
Description Product No.
120 VAC/125 VDC FCEMF3
220/240 VAC, 50/60 Hz FCEMF6 Padlock Fixed Toggle FC1PF
48 VDC FCEMFF Padlock EUSERC Toggle FC1PE

Plug-In Types
Type Description Product No.
Complete Kits 3 Pole - LSL - Horizontal Strap FCDDF1
Padlock
3 Pole - SLS - Horizontal Strap FCDDF2
3 Pole - LSL - Vertical Strap FCDDF3
3 Pole - SLS - Vertical Strap FCDDF4
Secondary Disconnect Secondary Disconnect Kit FCDSD
Secondary Disconnect - Base Part FCDSDP
Secondary Disconnect - Breaker Part FCDSDB
Mounting Plate Mounting Plate FCDMP

Hardware Kits
Description Product No. Plug-In Bases
Mounting screws for mounting plates with tapped holes, quantity 4 FCMSK3
(#8-32 x 2 7/8 screws with lockwashers)
Mounting screws for mounting plates with clearance holes, quantity 4 FCMSK4
(#8-32 x 3 screws with nuts lockwashers)
Nut plates (quantity 3) FCNP3
Nut plates (quantity 36) FCNPB

Plug-In Plate

6-78 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Molded Case Circuit Breakers Section 6
Record Plus FC 100
External Accessories
Lugs and Lug Kits
Single Lug Lug Kit
Amp Range Wire Range Strip Length Product No. Product No. (Set of 3)
15-20A 14-10 Cu/Al .40-.50 FCAL12 FCALK12
25-60A 10-4 Cu/Al .40-.50 FCAL13 FCALK13
70-100A 4-1/0 Cu/Al .40-.50 FCAL14 FCALK14

Lug Tightening Torque


Wire Size Torque
#10 AWG 35 in-lb
#8 AWG 40 in-lb
#6-#4 AWG 45 in-lb
#3 AWG - 1/0 50 in-lb

Handles and Handle Accessories


Type Description Product No.
STDA Flange Flange Handle for Variable Same as Spectra: 6-inch for NEMA 12/13 STDA1
Handles, Depth Operating Mechanism Same as Spectra: 10-inch for NEMA 12/13 STDA2
Operators, and Same as Spectra: 6-inch for NEMA 4/4X STDA1X
Hardware Kits Same as Spectra: 10-inch for NEMA 4/4X STDA2X
Flange Operating Mechanism Operating Mechanism Only FCNFM
Flange Stiffener Kit Use with FCNFM TDSR
Extender Kit Use with FCNFM TDSR
Extended Drive Stud Use with FCNFM TDS1
Door Hardware Kit NEMA12/13 Door Hinged on Left, NEMA 12/13, 2-point Kit TDV1
Door Hardware Kit NEMA 4/4X Door Hinged on Left, NEMA 4/4X, 2-point Kit TDV1X
Third Point Latch Kit For Use With TDV1/TDV1X Above TDV3
Door Hardware Kit NEMA12/13 Door Hinged on Right, NEMA 12/13 2-point Kit TDV1L
Third Point Latch Kit For Use with TDV1L, TDC1LX Above TDV3L STDA Flange Handles
Auxiliary DPDT for STDA Handle on Right TDAS1L2
Contact Kits DPDT for STDA Handle on Left TDAS1R2 and Operators

Dimensions in. (mm)

FC 100 Dimensions A D

Frame A B C D E F G H B E E

FC 3.7 (29.1) 3.2 (81.3) .96 (24.4) 3.0 (76.2) 1.0 (25.4) 6.4 (162.6) 5.0 (127.0) 1.0 (25.4) C H

G F

FC 100 Amp Dimensions

Rev. 11/13 www.geindustrial.com BuyLog Catalog 6-79


Data subject to change
without notice
Molded Case Circuit Breakers Section 6
Record Plus FE 250

Reference Publications
Available for download from www.geindustrial.com/publibrary
1 FE Breaker
Breaker Frame Rating Installation Instructions DEH-41640
2 Product Description Outline Drawing 10101247PV1
1 3 Standards & Markings FE Breaker Accessories
2
4 Bell Alarm & Aux Switch DEH-40324
Interrupting Ratings Shunt Trip & UVR DEH-40259
3 5 Lug Data & Torque Info Padlock Device DEH-41059
4
6 Product Number Lug Kits DEH-41054
Auxiliary Contacts DEH-40261
5 7 Push to Trip Panelboards
7 6 Spectra Power Panel - Plug-in Kits DEH-40402
Spectra Power Panel - Bolt-on Kits DEH-40425
Series Ratings DET-008
External Operators
STDA Style DEH-41014
TDM Style DEH-41025

Trip Curves
Main Standards Record Plus FE with PremEon S Trip - LSI Protections DES-115
Record Plus FE with PremEon S Trip - GF Protection DES-116
UL /cUL 489
Record Plus FE with PremEon S Trip - Mag only Motor Circuit Protector DES-117
HACR (heating, air conditioning, and refrigeration) Peak Current Curves DES-205
Naval Peak l2t Curve DES-206

Interrupting Ratings
UL Listed Interrupting Ratings -
rms Symmetrical Amperes (in Thousands) AC Voltage
Type Ampere Rating Max Voltage No. Poles 240 480
2 150 65
FEN 25-250A 480VAC
3 150 65
2 200 100
FEH 25-250A 480VAC
3 200 100

Cross Reference
SMR1 Equipped FE MCCB Rating Plug Amps PremEon Equipped MCCB
FE(N/H)(2/3)4AA0025R 20, 25 FE(N/H)(2/3)4DB025KF
FE(N/H)(2/3)4AA0060R 25, 30, 40, 50, 60 FE(N/H)(2/3)4DB060KF
FE(N/H)(2/3)4AA0125R 50, 60, 70, 80, 90, 100 ,110 ,125 FE(N/H)(2/3)4DB125KF
FE(N/H)(2/3)4AA0150R 70, 80, 90, 100, 110, 125, 150 FE(N/H)(2/3)4DB150KF
FE(N/H)(2/3)4AA0250R 100, 110, 125, 150, 175, 200, 225, 250 FE(N/H)(2/3)4DB250KF

Product Number Structure

F E N 3 4 D B 250 K F

Interruption Connection
Family Frame Size Rating (@480VAC) Poles Voltage Trip Unit Type Trip Unit Protection Trip Unit Amps Frame Amps Configuration
F = Record Plus E = 250A N = 65kA 2 = 2-Pole 4 = 480VAC D = PremEon S1 B = LI 025 = 25A K = 250A F = Standard,
H = 100kA in 3-Pole Frame C = LI 400 Hz 060 = 60A No Lugs
3 = 3 Pole G = LIG 125 = 125A
w/ Ground Fault 150 = 150A
250 = 250A
M =Mag-Only MCP
P = Mag-Only MCP
w/ Ground Fault

1Requires tamper-resistant Torx T15 tool for adjustment.

6-80 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Molded Case Circuit Breakers Section 6
Record Plus FE 250
Breaker Frames

FE Breakers and MCP's equipped with the PremEon trip unit do not
use Rating Plugs to determine Amp rating. The trip unit features
an adjustment knob to set the Amp rating (Long-Time Pickup).
The knob is located behind a sealable cover and requires a
tamper-resistant Torx T15 tool. The tool is available through many
industrial supply companies. The maximum Amp rating of the
breaker frame is shown in the "Current Sensor" column below.
The available Amp rating settings (LT Pickup values), by sensor, are
as follows:

Current Sensor (A) Amp Settings (LT Pickup)


25 8, 9, 10, 11, 13, 14, 15, 16, 18, 19, 20, 21, 23, 24, 25
60 18, 20, 25, 27, 30, 33, 35, 40, 42, 45, 48, 50, 54, 57, 60
125 40, 45, 50, 60, 65, 70, 75, 80, 90, 95, 100, 105, 110, 120, 125
150 45, 50, 60, 70, 75, 80, 90, 100, 105, 110, 120, 125, 135, 145, 150
250 80, 90, 100, 110, 125, 135, 150, 165, 175, 190, 200, 215, 225, 240, 250

LI Trip Unit (With Tracking Short-Time) LIG Trip Unit (With Tracking Short-Time)
2-Pole Record Plus FE Breakers 2-Pole Record Plus FE Breakers
65kAIC @ 480 Vac 100kAIC @ 480 VAC 65kAIC @ 480 Vac 100kAIC @ 480 VAC
Current Sensor (A) Product Number Product Number Current Sensor (A) Product Number Product Number
25 FEN24DB025KF FEH24DB025KF 25 FEN24DG025KF FEH24DG025KF
60 FEN24DB060KF FEH24DB060KF 60 FEN24DG060KF FEH24DG060KF
125 FEN24DB125KF FEH24DB125KF 125 FEN24DG125KF FEH24DG125KF
150 FEN24DB150KF FEH24DB150KF 150 FEN24DG150KF FEH24DG150KF
250 FEN24DB250KF FEH24DB250KF 250 FEN24DG250KF FEH24DG250KF

3-Pole Record Plus FE Breakers 3-Pole Record Plus FE Breakers


65kAIC @ 480 Vac 100kAIC @ 480 VAC 65kAIC @ 480 Vac 100kAIC @ 480 VAC
Current Sensor (A) Product Number Product Number Current Sensor (A) Product Number Product Number
25 FEN34DB025KF FEH34DB025KF 25 FEN34DG025KF FEH34DG025KF
60 FEN34DB060KF FEH34DB060KF 60 FEN34DG060KF FEH34DG060KF
125 FEN34DB125KF FEH34DB125KF 125 FEN34DG125KF FEH34DG125KF
150 FEN34DB150KF FEH34DB150KF 150 FEN34DG150KF FEH34DG150KF
250 FEN34DB250KF FEH34DB250KF 250 FEN34DG250KF FEH34DG250KF

400 Hz LI Trip Unit (With Tracking Short-Time)1


2-Pole Record Plus FE Breakers
65kAIC @ 480 Vac 100kAIC @ 480 VAC
Current Sensor (A) Product Number Product Number
25 FEN24DB025KF FEH24DB025KF
60 FEN24DB060KF FEH24DB060KF
125 FEN24DB125KF FEH24DB125KF
150 FEN24DB150KF FEH24DB150KF
250 FEN24DB250KF FEH24DB250KF

3-Pole Record Plus FE Breakers


65kAIC @ 480 Vac 100kAIC @ 480 VAC
Current Sensor (A) Product Number Product Number
25 FEN34DB025KF FEH34DB025KF
60 FEN34DB060KF FEH34DB060KF
125 FEN34DB125KF FEH34DB125KF
150 FEN34DB150KF FEH34DB150KF
250 FEN34DB250KF FEH34DB250KF
1400 Hz FE breakers require de-rating and are not UL listed.

Rev. 11/13 www.geindustrial.com BuyLog Catalog 6-81


Data subject to change
without notice
Molded Case Circuit Breakers Section 6
Record Plus FE 250
Internal and External Accessories

PremEon S External Ground Fault CTs


Description Product Number
25A External Neutral CT for FE with PremEon S FEGS0025
60A External Neutral CT for FE with PremEon S FEGS0060
125A External Neutral CT for FE with PremEon S FEGS0125
150A External Neutral CT for FE with PremEon S FEGS0150
250A External Neutral CT for FE with PremEon S FEGS0250

Releases Shunt Trip and Undervoltage


Shunt Trip Undervoltage Release
Voltage Product No. Product No.
12 VDC FASHTBW
24 VAC/DC FASHTDW FAUVRDW
48 VAC/DC FASHTFW FAUVRFW
110-130 VAC/110-125 VDC FASHTJW FAUVRJW
120 VAC FASHTKW
220/240 VAC, 250 VDC FASHTNW FAUVRNW
277 VAC FASHT7W FAUVR7W
400/480 VAC FASHTUW FAUVRUW

UL Listed for field installation. Accessories are prewired from the factory with 36 inch long leads
(#18 AWG). Shunt trip wire leads are black and UVR wire leads are blue.

Bell Alarm
Contact
Configuration Contact Rating Wire leads Product No.
1 NO (Form A) 5A @ 277 VAC, #16 AWG FABAM10W
0.3A @ 125 VDC
1 NC (Form B) 5A @ 277 VAC, #16 AWG FABAM01W
0.3A @ 125 VDC

UL Listed for field installation. Accessories are prewired from the factory with 36 inch long leads. Reference
instruction sheet DEH-40324 for wire lead colors.

Auxiliary Switches
Contact Left Mount Right Mount
Configuration Contact Rating Wire leads Product No. Product No.
Bell Alarm
1 NO (Form A) 5A @ 277 VAC, #16 AWG FAS10LW FAS10RW Mechanism
0.3A @ 125 VDC Auxiliary
1 NC (Form B) 5A @ 277 VAC, #16 AWG FAS01LW FAS01RW Switch
0.3A @ 125 VDC
Auxiliary
UL Listed for field installation. Accessories are prewired from the factory with 36 inch long leads. Reference Switch
instruction sheet DEH-40324 for wire lead colors.

Mounting Locations and Limitations Shunt Trip or


Undervoltage
Accessory Mounting Pocket Location Maximum Quantity Release
Shunt Trip or Undervoltage Release 1
Aux. Switch - Left Mount 2
Aux. Switch - Right Mount 2
Bell Alarm Mechanism 1 Mounting Locations

Lug Kits
Lug Kit Lug Kit w/
Lug Torque Single Lug (3 Lugs + Lug Cover) Control Wire Terminal
Ampere Rating Conductor Size (Max) Product No. Product No. Product No.
150A #14 - 3/0 Cu / Al 150 in-lb FCAL15 FCALK15 FCALK15LV
250A #8 - 250MCM Cu / #8 - 350MCM Al 275 in-lb FCAL16 FCALK16 FCALK16LV

6-82 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Molded Case Circuit Breakers Section 6
Record Plus FE 250
Internal and External Accessories

Mounting Screw Kits Dimensions in. (mm)


Description Product Number
FE 250 Dimensions
Mounting Screw Kit (#10) for Tapped Holes FEMSK1

Padlocking Device
Description Product Number
104.4

EUSERC Compliant Padlock FE1PE 35.0 35.0

Other Accessories
Description Product Number
L

Fin Cover FEUA3


Terminal Shield Fin Cover FEJS3 96.40
64.00
Nut Plate / Terminal Shoe FEJN3

60.63 .30

External Operators 27.55

Type Description Product Number


35.0 35.0
Same as Spectra 6 inch for NEMA 12/13 STDA1
STDA Flange Handle for Variable Same as Spectra 10 inch for NEMA 12/13 STDA2
Depth Operating Mechanism Same as Spectra 6 inch for NEMA 4/4X STDA1X
Same as Spectra 10 inch for NEMA 4/4X STDA2X
Flange Stiffener Kit Use with FENFM TDSR
STDA Flange
Extender Kit Use with FENFM TDSR 107.75
Handles and [4.24]
Extended Drive Stud Use with FENFM TDS1
Hardware Kits 93.55 .30
[ 3.68 .01 ]
Door Hardware Kit NEMA 12/13 Door Hinged on Left, NEMA 12/13 2-point Kit TDV1
89.5
Door Hardware Kit NEMA 4/4X Door Hinged on Left, NEMA 4/4X 2-point Kit TDV1X [ 3.5 ]
80.50 .30
[ 3.17 .01 ]
Third Point Latch Kit For Use with TDV1L, TDC1LX Above TDV3 77.0
[ 3.0 ]
Door hardware Kit NEMA 12/13 Door Hinged on Right, NEMA 12/13 2-point Kit TDV1L 52.60
[2.07]
Third Point Latch Kit For Use with TDV1L, TDC1LX Above TDV3L
TDM Style Handle Handle for FENRM2 / FENRM4 THCH45
Operators
LINE END
ON
17.68 1.20
1.58 1.10 47.4
TRIP
[ 1.9 ]

20.87 2.00 OFF R3.3


[ .1 ]
22.14 1.60
RESET
LOAD END
94.5
[ 3.7 ]

52.60
73.5 [ 2.07 ]
77.0 [ 2.9 ]
81.0 [ 3.0 ]
[ 3.2 ]
108.36 .30
[ 4.27 .01 ] 111.76 .30
[ 4.400 .011 ]

35.0 R4.75
17.5 18.0

7.30
L

139.78 .30

R 125.53
170.10 .50

5.70 9.00

.50 4.95

3.08

18.00
19.00
15.60 .30

Rev. 11/13 www.geindustrial.com BuyLog Catalog 6-83


Data subject to change
without notice
Molded Case Circuit Breakers Section 6
Record Plus FG 600
Features SMR2
Record Plus
FG Molded Case Circuit Breakers are available with Standard
either PremEon S or advanced (SMR2) trip units. Fixed LT Pickup, set by Rating Plug Characteristic
Adjustable LT Delay
FG600 breakers and MCPs equipped with the PremEon trip unit do Adjustable ST Pickup and Delay
not use rating plugs to determine Amp rating. The trip unit Adjustable INST Pickup
features an adjustment knob to set the Amp rating (Long-Time Optional
Pickup). The knob is located behind a sealable cover and requires Adjustable LT Pickup2
a tamper-resistant Torx T15 tool. The tool is available through Zone Selective Interlocking Capability3
many industrial supply companies. The maximum Amp rating of Adjustable GF (Alarm or Trip) Pickup and Delay
the breaker frame and the available Amp rating settings (Long- Trip Unit Flag for Trip Reason Indication
Time Pickup values) by sensor, are shown on page 6-85. FG600 Ammeter
breakers equipped with SMR2 trip units require rating plugs to Load Shedding Contact
determine the breakers current rating, but also allow individual Communications via Modbus
adjustment of Long-Time delay, Short-Time pickup and Delay, and
Ground Fault Pickup and Delay (if so equipped). Zone Selective Standard features of SMR2 trip units are supplied installed on
Interlocking (ZSI), Ground Fault Alarm, and Modbus the breaker frame. Zone Selective Interlocking must be ordered
Communications are also available via the SMR2s interface. on the breaker frame, and cannot be user-defeated. Adjustable
Long-Time pickup functionality is achieved through the use of
PremEon S adjustable rating plugs, which must be ordered separately from
Standard the breaker frame, and sized to match the CT/Sensor rating of
Adjustable INST Pickup the frame.
Adjustable LT Pickup1
Optional Optional features of the SMR2 (except ZSI) are available via user-
Adjustable GF Pickup and Delay installed expansion modules, which, like rating plugs, must be
ordered separately.

Reference Publications
Available for download from www.geindustrial.com/publibrary
FG Breaker
1 Breaker Frame Rating Installation Instructions DEH-41639
2 Product Description FG Breaker Accessories
1 2 3 Bell Alarm & Aux. Switch DEH-40324
3 Standards & Markings Shunt Trip & UVR DEH-40259
4 Interrupting Ratings Padlock Device DEH-41031
4
5 Lug Kits DEH-40404
5 Lug Data & Torque Info Auxiliary Contacts DEH-40261
6 6 Product Number Trip Unit Test Kit (FAT) DEH-40358
7 Push to Trip SMR2 Expansion Modules DEH-40408
SMR2 Modbus User Manual DEH-41181
7 SMR2 External Contact Module DEH-40409
Panelboards
Spectra Power Panel - Plug-in Kits - Single DEH-40420
Spectra Power Panel - Plug-in Kits - Double DEH-40419
Spectra Power Panel - Bolt-on Kits - Single DEH-40426
Spectra Power Panel - Bolt-on Kits - Double DEH-41047
Series Ratings DET-008
Outline Drawing 10085108SHI

Main Standards Trip Curves


Peak Current Curve DES-040
UL489/cUL489
Peak l2t Curve DES-041
IEC 947 and associated EN Sections Record Plus FG with PremEon Trip - LSI Protections DES-118
Record Plus FG with PremEon Trip - GF Protection DES-119
Other Global Standards Record Plus FG with PremEon Trip - Mag-only
Motor Circuit Protector DES-120
BS, CE, CEI, JIS, UNE, VDE SMR2 Trip Unit
Phase Protection DES-201
FG Breaker Markings Ground Fault Protection and Alarm DES-202

cULus UL File E-11592


Cross Reference
HACR 250 to 600A
Cu/Al 60/75C 250 to 600A SMR1 Equippped FG MCCB Rating Plug Amps PremEon Equipped MCCB
Current Limiting 250 to 600A FG(N/H/L/P)(2/3)6AA0250R_ _ 100, 110, 125, 150, FG(N/H/L/P)(2/3)6DB250LF
175, 200, 225, 250
1Available via adjustment with special Torx T15 tool
FG(N/H/L/P)(2/3)6AA0400R_ _ 175, 200, 225, 250, FG(N/H/L/P)(2/3)6DB400LF
2Available via Adjustable Rating Plug 300, 350, 400
3Must be ordered on the breaker frame FG(N/H/L/P)(2/3)6AA0600R_ _ 300, 350, 400, 450, 500, 600 FG(N/H/L/P)(2/3)6DB600MF

6-84 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Molded Case Circuit Breakers Section 6
Record Plus FG 600
Interrupting Ratings
UL Listed Interrupting Ratings - EN 60947-2 Interrupting Ratings -
rms Symmetrical Amperes (in Thousands) AC Voltage rms Symmetrical Amperes (in Thousands)
Type Ampere Rating Max Voltage No. Poles 240 480 600 240 400-415 690
2 150 65 25
FGN 250-600A 600VAC
3 150 65 25 85 50 10
2 200 100 35
FGH 250-600A 600VAC
3 200 100 35 100 80 22
2 200 150 42
FGL1 250-600A 600VAC
3 200 150 42 200 150 40
2 200 200 65
FGP1 250-600A 600VAC
3 200 200 65
1Not suitable for reverse feed.

Product Number Structure


F G N 3 6 D B 250L F

Connection
Family Frame Size Interruption Rating Poles Voltage Trip Unit Type Trip Unit Protection Trip Unit/Frame Amps Configuration
F = Record Plus G = 600A (@480VAC) 2 = 2-Pole 6 = 600VAC D = PremEon S2 A = SMR2 standard 0250 = 250A SMR2 R0 = Standard No Lugs
N = 65kA in 3-Pole Frame K = SMR2 Z = SMR2 with ZSI 0400 = 400A SMR2 R1 = Line and Load Lugs3
H = 100kA 3 = 3-Pole B = LI 0600 = 600A SMR2 R2 = Load Lugs3
L = 150kA C = LI 400 Hz 250L = 250A PremEon R3 = Line Lugs3
P = 200kA G = LIG w/Ground Fault 400L = 400A PremEon
M = Mag-Only MCP 600M = 600A PremEon F = PremEon Standard
P = Mag-Only MCP No Lugs

2Requires tamper-resistant Torx T15 tool for adjustment w/Ground Fault

3Lugs included but not installed

PremEon S
FG Breakers and MCP's equipped with the PremEon S trip unit use an adjustment knob to set the Amp rating (LT Pickup). The maximum
Amp rating of the breaker frame is shown in the "Current Sensor" column below. The available Amp rating settings (LT Pickup values),
by sensor, are as follows:
Current Sensor (A) Amp Settings (LT Pickup)
250 80, 90, 100, 110, 125, 135, 150, 165, 175, 190, 200, 215, 225, 240, 250
400 125, 150, 175, 180, 200, 225, 240, 250, 275, 300, 325, 340, 350, 375, 400
600 175, 200, 225, 250, 300, 325, 350, 400, 425, 450, 475, 500, 550, 575, 600

LI Trip Unit (With Tracking Short-Time)


2-Pole Record Plus FG Breakers
65kAIC @480 Vac 100kAIC @480 Vac 150kAIC @480 Vac 200kAIC @480 Vac
Current Sensor (A) Product Number Product Number Product Number Product Number
250 FGN26DB250LF FGH26DB250LF FGL26DB250LF FGP26DB250LF
400 FGN26DB400LF FGH26DB400LF FGL26DB400LF FGP26DB400LF
600 FGN26DB600MF FGH26DB600MF FGL26DB600MF FGP26DB600MF

3-Pole Record Plus FG Breakers


65kAIC @480 Vac 100kAIC @480 Vac 150kAIC @480 Vac 200kAIC @480 Vac
Current Sensor (A) Product Number Product Number Product Number Product Number
250 FGN36DB250LF FGH36DB250LF FGL36DB250LF FGP36DB250LF
400 FGN36DB400LF FGH36DB400LF FGL36DB400LF FGP36DB400LF
600 FGN36DB600MF FGH36DB600MF FGL36DB600MF FGP36DB600MF

LIG Trip Unit (With Tracking Short-Time)


2-Pole Record Plus FG Breakers
65kAIC @480 Vac 100kAIC @480 Vac 150kAIC @480 Vac 200kAIC @480 Vac
Current Sensor (A) Product Number Product Number Product Number Product Number
250 FGN26DG250LF FGH26DG250LF FGL26DG250LF FGP26DG250LF
400 FGN26DG400LF FGH26DG400LF FGL26DG400LF FGP26DG400LF
600 FGN26DG600MF FGH26DG600MF FGL26DG600MF FGP26DG600MF

3-Pole Record Plus FG Breakers


65kAIC @480 Vac 100kAIC @480 Vac 150kAIC @480 Vac 200kAIC @480 Vac
Current Sensor (A) Product Number Product Number Product Number Product Number
250 FGN36DG250LF FGH36DG250LF FGL36DG250LF FGP36DG250LF
400 FGN36DG400LF FGH36DG400LF FGL36DG400LF FGP36DG400LF
600 FGN36DG600MF FGH36DG600MF FGL36DG600MF FGP36DG600MF

400 Hz LI Trip Unit (With Tracking Short-Time)4


2-Pole Record Plus FG Breakers
65kAIC @480 Vac 100kAIC @480 Vac 150kAIC @480 Vac 200kAIC @480 Vac
Current Sensor (A) Product Number Product Number Product Number Product Number
250 FGN26DC250LF FGH26DC250LF FGL26DC250LF FGP26DC250LF
400 FGN26DC400LF FGH26DC400LF FGL26DC400LF FGP26DC400LF
600 FGN26DC600MF FGH26DC600MF FGL26DC600MF FGP26DC600MF

3-Pole Record Plus FG Breakers


65kAIC @480 Vac 100kAIC @480 Vac 150kAIC @480 Vac 200kAIC @480 Vac
Current Sensor (A) Product Number Product Number Product Number Product Number
250 FGN36DC250LF FGH36DC250LF FGL36DC250LF FGP36DC250LF
400 FGN36DC400LF FGH36DC400LF FGL36DC400LF FGP36DC400LF
600 FGN36DC600MF FGH36DC600MF FGL36DC600MF FGP36DC600MF
4400 Hz FG breakers require de-rating and are not UL listed.

Rev. 11/13 www.geindustrial.com BuyLog Catalog 6-85


Data subject to change
without notice
Molded Case Circuit Breakers Section 6
Record Plus FG 600

Record Plus FG with SMR2 Trip Unit, Breaker Frames without ZSI and Fixed Rating Plugs

2-Pole
Fixed Rating Plug Breaker Frame
UL 489 65kA IC @ 480 Vac UL 489 100kA IC @ 480 Vac UL 489 150kA IC @ 480 Vac UL 489 200kA IC @ 480 Vac
Ampere Current
Rating Product No. Sensor Product No. Product No. Product No. Product No.
100A FGRM2K0100
110A FGRM2K0110
125A FGRM2K0125 R0 R0 R0 R0
150A FGRM2K0150 250 R1 R1 R1 R1
FGN26KA0250_ _ FGH26KA0250_ _ FGL26KA0250_ _ FGP26KA0250_ _
175A FGRM2K0175 R2 R2 R2 R2
200A FGRM2K0200 R3 R3 R3 R3
225A FGRM2K0225
250A FGRM2K0250
175A FGRM2L0175
200A FGRM2L0200
R0 R0 R0 R0
225A FGRM2L0225
400 R1 R1 R1 R1
250A FGRM2L0250 FGN26KA0400_ _ FGH26KA0400_ _ FGL26KA0400_ _ FGP26KA0400_ _
R2 R2 R2 R2
300A FGRM2L0300
R3 R3 R3 R3
350A FGRM2L0350
400A FGRM2L0400
300A FGRM2M0300
350A FGRM2M0350 R0 R0 R0 R0
400A FGRM2M0400 600 R1 R1 R1 R1
FGN26KA0600_ _ FGH26KA0600_ _ FGL26KA0600_ _ FGP26KA0600_ _
450A FGRM2M0450 R2 R2 R2 R2
500A FGRM2M0500 R3 R3 R3 R3
600A FGRM2M0600

3-Pole
Fixed Rating Plug Breaker Frame
UL 489 65kA IC @ 480 Vac UL 489 100kA IC @ 480 Vac UL 489 150kA IC @ 480 Vac UL 489 200kA IC @ 480 Vac
Ampere Current
Rating Product No. Sensor Product No. Product No. Product No. Product No.
100A FGRM3K0100
110A FGRM3K0110
125A FGRM3K0125 R0 R0 R0 R0
150A FGRM3K0150 250 R1 R1 R1 R1
FGN36KA0250_ _ FGH36KA0250_ _ FGL36KA0250_ _ FGP36KA0250_ _
175A FGRM3K0175 R2 R2 R2 R2
200A FGRM3K0200 R3 R3 R3 R3
225A FGRM3K0225
250A FGRM3K0250
175A FGRM3L0175
200A FGRM3L0200
R0 R0 R0 R0
225A FGRM3L0225 400 R1 R1 R1 R1
250A FGRM3L0250 FGN36KA0400_ _ FGH36KA0400_ _ FGL36KA0400_ _ FGP36KA0400_ _
R2 R2 R2 R2
300A FGRM3L0300
R3 R3 R3 R3
350A FGRM3L0350
400A FGRM3L0400
300A FGRM3M0300
350A FGRM3M0350 R0 R0 R0 R0
400A FGRM3M0400 600 R1 R1 R1 R1
FGN36KA0600_ _ FGH36KA0600_ _ FGL36KA0600_ _ FGP36KA0600_ _
450A FGRM3M0450 R2 R2 R2 R2
500A FGRM3M0500 R3 R3 R3 R3
600A FGRM3M0600

Adjustable Rating Plugs for Record Plus FG with SMR2 Trip Unit
Ampere Current Sensor
Poles Rating Product No. Rating
160A FGRN2K0160 250
250A FGRN2K0250
2-Pole 250A FGRN2L0250 400
400A FGRN2L0400
600A FGRN2M0600 600
160A FGRN3K0160
250
250A FGRN3K0250
3-Pole 250A FGRN3L0250
400
400A FGRN3L0400
600A FGRN3M0600 600

6-86 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Molded Case Circuit Breakers Section 6
Record Plus FG 600

Record Plus FG with SMR2 Trip Unit, Breaker Frames with ZSI and Fixed Rating Plugs

2-Pole
Fixed Rating Plug Breaker Frame
UL 489 65kA IC @ 480 Vac UL 489 100kA IC @ 480 Vac UL 489 150kA IC @ 480 Vac UL 489 200kA IC @ 480 Vac
Ampere Current
Rating Product No. Sensor Product No. Product No. Product No. Product No.
100A FGRM2K0100 $106.00
110A FGRM2K0110
125A FGRM2K0125 R0 R0 R0 R0
150A FGRM2K0150 250 R1 R1 R1 R1
FGN26KZ0250_ _ FGH26KZ0250_ _ FGL26KZ0250_ _ FGP26KZ0250_ _
175A FGRM2K0175 R2 R2 R2 R2
200A FGRM2K0200 R3 R3 R3 R3
225A FGRM2K0225
250A FGRM2K0250
175A FGRM2L0175
200A FGRM2L0200
R0 R0 R0 R0
225A FGRM2L0225
400 R1 R1 R1 R1
250A FGRM2L0250 FGN26KZ0400_ _ FGH26KZ0400_ _ FGL26KZ0400_ _ FGP26KZ0400_ _
R2 R2 R2 R2
300A FGRM2L0300
R3 R3 R3 R3
350A FGRM2L0350
400A FGRM2L0400
300A FGRM2M0300
350A FGRM2M0350 R0 R0 R0 R0
400A FGRM2M0400 600 R1 R1 R1 R1
FGN26KZ0600_ _ FGH26KZ0600_ _ FGL26KZ0600_ _ FGP26KZ0600_ _
450A FGRM2M0450 R2 R2 R2 R2
500A FGRM2M0500 R3 R3 R3 R3
600A FGRM2M0600

3-Pole
Fixed Rating Plug Breaker Frame
UL 489 65kA IC @ 480 Vac UL 489 100kA IC @ 480 Vac UL 489 150kA IC @ 480 Vac UL 489 200kA IC @ 480 Vac
Ampere Current
Rating Product No. Sensor Product No. Product No. Product No. Product No.
100A FGRM3K0100
110A FGRM3K0110
125A FGRM3K0125 R0 R0 R0 R0
150A FGRM3K0150 250 R1 R1 R1 R1
FGN36KZ0250_ _ FGH36KZ0250_ _ FGL36KZ0250_ _ FGP36KZ0250_ _
175A FGRM3K0175 R2 R2 R2 R2
200A FGRM3K0200 R3 R3 R3 R3
225A FGRM3K0225
250A FGRM3K0250
175A FGRM3L0175
200A FGRM3L0200
R0 R0 R0 R0
225A FGRM3L0225 400 R1 R1 R1 R1
250A FGRM3L0250 FGN36KZ0400_ _ FGH36KZ0400_ _ FGL36KZ0400_ _ FGP36KZ0400_ _
R2 R2 R2 R2
300A FGRM3L0300
R3 R3 R3 R3
350A FGRM3L0350
400A FGRM3L0400
300A FGRM3M0300
350A FGRM3M0350 R0 R0 R0 R0
400A FGRM3M0400 600 R1 R1 R1 R1
FGN36KZ0600_ _ FGH36KZ0600_ _ FGL36KZ0600_ _ FGP36KZ0600_ _
450A FGRM3M0450 R2 R2 R2 R2
500A FGRM3M0500 R3 R3 R3 R3
600A FGRM3M0600

Adjustable Rating Plugs for Record Plus FG with SMR2 Trip Unit
Ampere Current Sensor
Poles Rating Product No. Rating
160A FGRN2K0160 250
250A FGRN2K0250
2-Pole 250A FGRN2L0250 400
400A FGRN2L0400
600A FGRN2M0600 600
160A FGRN3K0160
250
250A FGRN3K0250
3-Pole 250A FGRN3L0250
400
400A FGRN3L0400
600A FGRN3M0600 600

Rev. 11/13 www.geindustrial.com BuyLog Catalog 6-87


Data subject to change
without notice
Molded Case Circuit Breakers Section 6
Record Plus FG 600
Internal Accessories
SMR2 Expansion Modules
Description Product Number
Blank Filler FAMB2
Ground Fault Protection and Trip Reason Indication FAMGFT2
Load Shedding and Communications FAMSM21
Spare / Replacement Battery FAMBAT
External, DIN-rail Mounted, Communications Module FAMECM2
1Requires FAMECM Communications Module.
2Required for Communications, also serves as contact module for load shedding function.

PremEon S/SMR2 External Ground Fault CTs


Description Product Number
250A External Neutral CT for FG with SRM2 FGGS0250
400A External Neutral CT for FG with SRM2 FGGS0400
600A External Neutral CT for FG with SRM2 FGGS0600

Releases Shunt Trip and Undervoltage


Shunt Trip Undervoltage Release
Voltage Product No. Product No.
12 VDC FASHTBW
24 VAC/DC FASHTDW FAUVRDW
48 VAC/DC FASHTFW FAUVRFW
110-130 VAC/110-125 VDC FASHTJW FAUVRJW
120 VAC3 FASHTKW
220/240 VAC, 250 VDC FASHTNW FAUVRNW
277 VAC FASHT7W FAUVR7W
400/480 VAC FASHTUW FAUVRUW

UL Listed for field installation. Accessories are prewired from the factory with 36 inch long leads
(#18 AWG). Shunt trip wire leads are black and UVR wire leads are blue.
355% pickup as required for use with External Ground Fault Protection.

Bell Alarm
Mechanisms Trip Units
Contact
Configuration Contacts Contact Rating Wire leads Product No. Product No.
1 NO (Form A) Standard 5A @ 277 VAC, #16 AWG FABAM10W FABAT10W
0.3A @ 125 VDC
1 NC (Form B) Standard 5A @ 277 VAC, #16 AWG FABAM01W FABAT01W
0.3A @ 125 VDC

UL Listed for field installation. Accessories are prewired from the factory with 36 inch long leads. Reference
instruction sheet DEH-40324 for wire lead colors.

Auxiliary Switches
Left Mount Right Mount
Contact
Configuration Contacts Contact Rating Wire leads Product No. Product No.
1 NO (Form A) Standard 5A @ 277 VAC, #16 AWG FAS10LW FAS10RW
0.3A @ 125 VDC
1 NC (Form B) Standard 5A @ 277 VAC, #16 AWG FAS01LW FAS01RW
0.3A @ 125 VDC

UL Listed for field installation. Accessories are prewired from the factory with 36 inch long leads. Reference
instruction sheet DEH-40324 for wire lead colors.

Mounting Locations and Limitations

Accessory Mounting Pocket Location Maximum Quantity


Shunt Trip or Undervoltage Release 1
Auxiliary Auxiliary
Aux. Switch - Left Mount 3 Switch Switch
Aux. Switch - Right Mount 2
Bell Alarm Bell Alarm
Bell Alarm Mechanism T 1 Mechanism Trip Unit
Bell Alarm Trip Unit 1

Shunt Trip or
Undervoltage
Release

Mounting Locations

6-88 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Molded Case Circuit Breakers Section 6
Record Plus FG 600
External Accessories

Padlocking Device
Description Product No.
Padlocking EUSERC Toggle FG1PE

Lug Kits
Top
Torque Strip Length
Pole/Lugs Location Wire Type Wire-Lug Lug-Strap Top Bottom Product No.
2 Top #8-400kcmil Cu, #8-#4 AWG Cu/Al 200 lb-in Bottom
#6-500kcmil Al 275 lb-in (31 N-m) (23 N-m) 7/8 1 5/8 FCALK218H
Bottom #2/0-600kcmil Cu/Al #3 AWG-600kcmil Cu/Al 200 lb-in
375 lb-in (42 N-m) (23 N-m)
3 Top #8-400kcmil Cu, #8-#4 AWG Cu/Al 200 lb-in
#6-500kcmil Al 275 lb-in (31 N-m) (23 N-m) FCALK218H/FCALK318H
7/8 1 5/8 FCALK318H
Bottom #2/0-600kcmil Cu/Al #3 AWG-600kcmil Cu/Al 200 lb-in
375 lb-in (42 N-m) (23 N-m)

Other Accessories
Product No.
Rating Plug Removal Tool (SMR1 and SMR2 only) FAR
Breaker External Test Kit (SMR1 and SMR2 only) FAT
Lug Cover Kit FGH1LCK
Hardware Kit (Tapped Holes) FGMSK1
Hardware Kit (Through Holes) FGMSK2
Terminal Shield Fin Cover FGJS3
Nut Plate / Terminal Shoe FGJN3

Dimensions (in.)

FG 600 Dimensions

Rev. 11/13 www.geindustrial.com BuyLog Catalog 6-89


Data subject to change
without notice
Molded Case Circuit Breakers Section 6
Molded Case Switches
100-1200A

Molded Case Switches Spectra RMS


UL File E-57546, CSA LR 91464, Includes fixed, high-set Instantaneous trip suitable for reverse feed.
Terminal Lugs for Maximum Short Circuit Withstand Rating2
Switch1 Front Connection (Cu/Al) (kA rms symmetrical)
Frame Ampere
Type Rating Product Number Product Number Wire Range 240 Vac 480 Vac 600 Vac
100 SEDA36AN0100 TCAL18 Aluminum: #12-3/0 200 100 25
SE150
150 SEDA36AN0150 Copper: #14-3/0
250 SFDA36AN0250 TCAL29 Aluminum: #8-350 kcmil 200 100 25
SF250
Copper: #8-350 kcmil
400 SGDA36AN0400 3-pole lug kit Aluminum: (2) 2/0-500 kcmil 200 100 65
600 SGDA36AN0600 TCLK3653 or (1) #8-600 kcmil
SG600
Copper: (2) 2/0-500 kcmil
or (1) #8-600 kcmil
800 SKDA36AN0800 TCAL81 Aluminum: (3) 3/0-500 kcmil
Copper: (3) 3/0-500 kcmil 100 65 42
SK1200 1000 SKDA36AN1000 TCAL125 Aluminum: (4) 250-500 kcmil
1200 SKDA36AN1200 Copper: (4) 250-500 kcmil

Molded Case Switches Nonautomatic Trip, Includes Cu/Al line and load lugs. For optional lugs, see page 6-103 and 6-104.
Type Ampere Rating Number of Poles Voltage Rating Product Number
TEB 100 1 120 Vac, 125 Vdc TEB111Y1004
TEB 100 2 240 Vac, 250 Vdc TEB122Y1004
TEB 100 3 240 Vac TEB132Y1004
TEB 100 3 240Vac TEB132YT1009
TED 100 1 277 Vac, 125 Vdc TED113Y1004
TED 100 2 480 Vac, 250 Vdc TED124Y1004
TED 100 3 480Vac, 250Vdc TED134YT1009
TED 100 3 600Vac TED136YT1009
TED 100 3 600Vac TED136YT100A10
TED 150 2 480 Vac, 250 Vdc TED124Y1504,5
TED 150 3 480Vac, 250Vdc TED134YT1509
TED 150 3 600Vac TED136YT1509
TFJ 225 2 600 Vac TFJ226Y2254,6,11
TFJ 225 3 600 Vac TFJ236Y2256,11
TJJ 400 2 600 Vac, 250 Vdc TJJ426Y4007
TJJ 400 3 600 Vac TJJ436Y4007

Type Ampere Rating Number of Poles Voltage Rating Product Number


TFK 225 2 600 Vac, 250 Vdc TFK226Y2256,7,8,11
TFK 225 3 600 Vac, 250 Vdc TFK236Y2257,8,11
TJK 400 2 600 Vac, 250 Vdc TJK426Y4007
TJK 400 3 600 Vac, 250 Vdc TJK436Y4007
TJK 600 2 600 Vac, 250 Vdc TJK626Y6007
TJK 600 3 600 Vac, 250 Vdc TJK636Y6007
TKM 800 2 600 Vac, 250 Vdc TKMA826Y8007,11
TKM 800 3 600 Vac, 250 Vdc TKMA836Y8007,11
TKM 1000 2 600 Vac, 250 Vdc TKMA2Y10007,11
TKM 1000 3 600 Vac, 250 Vdc TKMA3Y10007,11
TKM 1200 2 600 Vac, 250 Vdc TKMA2Y12007,11
TKM 1200 3 600 Vac, 250 Vdc TKMA3Y12007,11

1No rating plug required.


2The maximum withstand rating is limited by the application to the value set forth in this table or the short circuit rating of the upstream fuse or circuit breaker, whichever is
less. The upstream protective device must have an instantaneous trip function or element and its rated ampacity may not exceed the ampere rating of the switch.
3Order one kit for either line or load end; two kits required for both.
4Internal accessory requires factory installed dummy trip. Specify on order. Accessories not available for one-pole TEB, TED.
5Not UL listed.
6600 Volts max.
7Internal accessory requires factory installed dummy trip unit. See page 6-44 for additional details. Nonautomatic trip unit and dummy trip not UL listed for field installation.
8UL listed only when ordered as a complete switch.
9Includes factory installed dummy trip for accessory installation.
10Includes factory installed dummy trip and TCAL12A lugs.
11Limited availability. Obsolete when inventory is depleted.

6-90 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Molded Case Circuit Breakers Section 6
Motor Circuit Protectors
3-250A
Mag-Break Motor Circuit Protectors
Current Limiting, UL Component Recognized1

Features
Suitable for Reverse Feed
UL Recognized File E-11592
CSA Certified LR 40350
IEC 947-2 690 Vac Max.
SE 150 160 Ampere Max.
SF250 250 Ampere Max.
SG600 630 Ampere Max.
SK1200 1250 Ampere Max.
UL Current Limiting

High Interrupting Capacity Spectra RMS Motor Circuit ProtectorsSE150 Line 3-Pole
Terminal Lugs for
Rating Plug Frame Front Connection (Cu/Al)
65kAIC @480 Vac 100kAIC @480 Vac
Adjustable Instantaneous
Ampere Trip Ampere Range Product Current Product Product Product Wire
Rating Low High Number Sensor Number Number Number Range
3 11 39 SRPE7A3
7 SELA36AI0007 SEPA36AI0007 TCAL18
7 22 90 SRPE7A7
15 43 182 SRPE30A15
20 58 254 SRPE30A20 30 SELA36AI0030 SEPA36AI0030 TCAL18
25 73 332 SRPE30A25
30 87 415 SRPE30A30 14-3/0 Cu
40 118 501 SRPE60A40
50 148 637 SRPE60A50 60 SELA36AI0060 SEPA36AI0060 TCAL18
60 178 777 SRPE60A60 12-3/0 Al
70 206 863 SRPE100A70
80 236 999 SRPE100A80 100 SELA36AI0100 SEPA36AI0100 TCAL18
90 267 1138 SRPE100A90
100 297 1280 SRPE100A100
110 328 1426 SRPE150A110
125 374 1640 SRPE150A125 150 SELA36AI0150 SEPA36AI0150 TCAL18
150 450 1991 SRPE150A150

SE150 Add-on 3-Pole Limiters


Maximum Product kAIC Use With Breaker/
Ampere Rating Number @600 Vac MCP Frame
150 SAXSEL36150 65 SEL
150 SAXSEP36150 100 SEP

High Interrupting Capacity Motor Circuit ProtectorsSF250 Line 3-Pole


Terminal Lugs for
Rating Plug Frame Front Connection (Cu/Al)
65kAIC @480 Vac 100kAIC @480 Vac
Adjustable Instantaneous
Ampere Trip Ampere Range Product Current Product Product Product Wire
Rating Low High Number Sensor Number Number Number Range
70 205 700 SRPF250A70
90 265 900 SRPF250A90
100 295 1000 SRPF250A100
110 325 1100 SRPF250A110
125 370 1250 SRPF250A125 250 SFLA36AI0250 SFPA36AI0250 TCAL29 8-350 Cu
150 440 1500 SRPF250A150 8-350 Al
175 515 1750 SRPF250A175
200 590 2000 SRPF250A200
225 665 2250 SRPF250A225
250 736 2500 SRPF250A250

1Per UL 489, interruption ratings are not printed on the product label (interruption ratings are established based on a tested combination of the motor circuit protector and a
properly sized overload relay and contactor).

Rev. 11/13 www.geindustrial.com BuyLog Catalog 6-91


Data subject to change
without notice
Molded Case Circuit Breakers Section 6
Motor Circuit Protectors
125-1200A
Mag-Break Motor Circuit Protectors
Current Limiting, UL Component Recognized1

SG 600 Line 3-Pole


Rating Plug Frame Terminal Lugs for Front Connection (Cu/Al)
65kAIC @480 Vac 100kAIC @480 Vac
Adjustable Instantaneous
Ampere Trip Ampere Range Product Current Product Product Product Wire
Rating Low High Number Sensor Number Number Number Range
400 Ampere Max.
125 380 1275 SRPG400A125
150 455 1530 SRPG400A150 3-Pole (2) 2/0-500 Cu or
175 530 1785 SRPG400A175 lug kit (1) 8-600 Cu
200 605 2040 SRPG400A200
225 680 2295 SRPG400A225 400 SGLA36AI0400 SGPA36AI0400 TCLK3652
250 755 2550 SRPG400A250
300 905 3060 SRPG400A300 (2) 2/0-500 Al or
350 1060 3570 SRPG400A350 (1) 8-600 Al
400 1210 4080 SRPG400A400

600 Ampere Max.


250 765 2530 SRPG600A250
300 915 3035 SRPG600A300 3-Pole (2) 2/0-500 Cu
350 1070 3545 SRPG600A350 lug kit or (1) 8-600 Cu
400 1220 4050 SRPG600A400
450 1375 4555 SRPG600A450 600 SGLA36AI0600 SGPA36AI0600 TCLK3652 (2) 2/0-500 Al
500 1525 5060 SRPG600A500 or (1) 8-600 Al
600 1830 6075 SRPG600A600
1Per UL 489, interruption ratings are not printed on the product label (interruption ratings are established based on a tested combination of the motor circuit protector and a
properly sized overload relay and contactor).
2Order one kit for either the line or load end; two kits required for both.

SK1200 Line (Not Current Limiting) 3-Pole


Rating Plug Frame Terminal Lugs for Front Connection (Cu/Al)
Adjustable Instantaneous 65kAIC @480 Vac
Trip Ampere Range
Ampere Product Current Product Product Wire
Rating Low High Number Sensor Number Number Range
800 Ampere Max.
300 940 3015 SRPK800A300
400 1250 4015 SRPK800A400 (3) 3/0-500 Cu
500 1570 5020 SRPK800A500 800 SKLA36AI0800 TCAL81
600 1875 6195 SRPK800A600
700 2155 7420 SRPK800A700 (3) 3/0-500 Al
800 2440 8705 SRPK800A800

1200 Ampere Max.


600 1825 6110 SRPK1200A600
700 2125 7125 SRPK1200A700 (4) 250-500 Cu
800 2430 8145 SRPK1200A800 1200 SKLA36AI1200 TCAL125
100 3040 10180 SRPK1200A1000 (4) 250-500 Al
1200 3650 12215 SRPK1200A1200

Accessories: See pages 6-39 to 6-44, 6-67 to 6-69 and 6-94 to 6-106.
Standard Capacity Mag Break Motor Circuit ProtectorsType TJC 3-Pole
30kAIC @480 Vac
Adjustable Instantaneous Complete Breaker (includes line and load lugs)
Trip Ampere Range Product
Ampere Rating Low High Number
330 1100 TJC36400E
550 1670 TJC36400F
400
1000 3300 TJC36400G
1200 4000 TJC36400B
1000 3300 TJC36600G
600
1800 6000 TJC36600H

6-92 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Molded Case Circuit Breakers Section 6
Motor Circuit Protectors
25-600A
Record Plus
Record Plus Mag-Break Motor Circuit Protectors
Current Limiting, UL Component Recognized1

High Interrupting Record Plus FE Motor Circuit Protectors - FE 250 Line with PremEon S
Mag-Only Motor Circuit Protector (With Tracking Short-Time) Mag-Only Motor Circuit Protector Plus Ground Fault (With Tracking Short-Time)
2-Pole Record Plus FE MCPs 2-Pole Record Plus FE MCPs
65kAIC @480 Vac 100kAIC @480 Vac 65kAIC @480 Vac 100kAIC @480 Vac
Current Sensor (A) Product Number Product Number Current Sensor (A) Product Number Product Number
25 FEN24DM025KF FEH24DM025KF 25 FEN24DP025KF FEH24DP025KF
60 FEN24DM060KF FEH24DM060KF 60 FEN24DP060KF FEH24DP060KF
125 FEN24DM125KF FEH24DM125KF 125 FEN24DP125KF FEH24DP125KF
150 FEN24DM150KF FEH24DM150KF 150 FEN24DP150KF FEH24DP150KF
250 FEN24DM250KF FEH24DM250KF 250 FEN24DP250KF FEH24DP250KF

3-Pole Record Plus FE MCPs 3-Pole Record Plus FE MCPs


65kAIC @480 Vac 100kAIC @480 Vac 65kAIC @480 Vac 100kAIC @480 Vac
Current Sensor (A) Product Number Product Number Current Sensor (A) Product Number Product Number
25 FEN34DM025KF FEH34DM025KF 25 FEN34DP025KF FEH34DP025KF
60 FEN34DM060KF FEH34DM060KF 60 FEN34DP060KF FEH34DP060KF
125 FEN34DM125KF FEH34DM125KF 125 FEN34DP125KF FEH34DP125KF
150 FEN34DM150KF FEH34DM150KF 150 FEN34DP150KF FEH34DP150KF
250 FEN34DM250KF FEH34DM250KF 250 FEN34DP250KF FEH34DP250KF

High Interrupting Record Plus FG Motor Circuit Protectors - FG 600 Line with PremEon S
Mag-Only Motor Circuit Protector (With Tracking Short-Time)
2-Pole Record Plus FG Breakers
65kAIC @ 480 Vac 100kAIC @ 480 Vac 150kAIC @ 480 Vac 200kAIC @ 480 Vac
Current Sensor (A) Product Number Product Number Product Number Product Number
250 FGN26DM250LF FGH26DM250LF FGL26DM250LF FGP26DM250LF
400 FGN26DM400LF FGH26DM400LF FGL26DM400LF FGP26DM400LF
600 FGN26DM600MF FGH26DM600MF FGL26DM600MF FGP26DM600MF

3-Pole Record Plus FG Breakers


65kAIC @ 480 Vac 100kAIC @ 480 Vac 150kAIC @ 480 Vac 200kAIC @ 480 Vac
Current Sensor (A) Product Number Product Number Product Number Product Number
250 FGN36DM250LF FGH36DM250LF FGL36DM250LF FGP36DM250LF
400 FGN36DM400LF FGH36DM400LF FGL36DM400LF FGP36DM400LF
600 FGN36DM600MF FGH36DM600MF FGL36DM600MF FGP36DM600MF

Mag-Only Motor Circuit Protector Plus Ground Fault (With Tracking Short-Time)

2-Pole Record Plus FG Breakers


65kAIC @ 480 Vac 100kAIC @ 480 Vac 150kAIC @ 480 Vac 200kAIC @ 480 Vac
Current Sensor (A) Product Number Product Number Product Number Product Number
250 FGN26DP250LF FGH26DP250LF FGL26DP250LF FGP26DP250LF
400 FGN26DP400LF FGH26DP400LF FGL26DP400LF FGP26DP400LF
600 FGN26DP600MF FGH26DP600MF FGL26DP600MF FGP26DP600MF

3-Pole Record Plus FG Breakers


65kAIC @ 480 Vac 100kAIC @ 480 Vac 150kAIC @ 480 Vac 200kAIC @ 480 Vac
Current Sensor (A) Product Number Product Number Product Number Product Number
250 FGN36DP250LF FGH36DP250LF FGL36DP250LF FGP36DP250LF
400 FGN36DP400LF FGH36DP400LF FGL36DP400LF FGP36DP400LF
600 FGN36DP600MF FGH36DP600MF FGL36DP600MF FGP36DP600MF
1Per UL 489, interruption ratings are not printed on the product label (interruption ratings are established based on a tested combination of the motor circuit protector and a
properly sized overload relay and contactor).

Rev. 11/13 www.geindustrial.com BuyLog Catalog 6-93


Data subject to change
without notice
Molded Case Circuit Breakers Section 6
External Accessories
Cable Operators

Spectra Flex Cable Operators


UL ListedFile E57253
Reduced installation costs:
Simpler, faster installation
No special alignment required
Optimized panel layout:
Breaker mounting position is independent of flange-mounted
handle location
Covers a full spectrum of enclosure types and sizes:
Flange-mounted handle for NEMA Types 1, 3R, 12
and 13 enclosures
Flange-mounted handle for NEMA 4/4X enclosuresoptional
Broad range of enclosure sizes and breaker
mounting configurations
8 different operating cable lengths available from 3 to 10 feet
For circuit breaker types E150, SE150, SF250, SG600
and SK1200
Force and motion transmitted independently of breaker
mounting plane or position relative to handle location
Common breaker mounted operator for SE150 and
SF250 frames
Spectra Flex cable operating mechanisms are suitable for
application with GE circuit breakers mounted in a wide variety of
flanged enclosure types and sizes.
Flange-mounted handle mechanisms are available for NEMA
Types 1, 12 or 13 enclosures in either 6 inch (Model SCH1) or
10 inch (Model SCH2) handle lengths. Corresponding mecha-
nisms, SCH1X and SCH2X, are available for NEMA Type 4/4X
enclosures. Handle mechanisms are suitable for either left or
right flange operation.
The handle mechanism is combined with one of eight operating
cables, with lengths from 3 to 10 feet, to cover a broad range of
possible breaker mounting locations in the enclosure. The cable
links the handle mechanism to the breaker-mounted operating
mechanism and transmits the mechanical force and motion of
the handle mechanism to the breaker mounted mechanism. The
force and motion is transmitted independently of the breaker
mounting plane or location relative to the location of the handle
mechanism, provided only that the bending radius of the cable is
not less than 3 inches. No mounting reinforcement of the breaker
or enclosure flange is required.
The breaker-operating mechanism mounts directly to the face of
the breaker and does not involve any mounting interface with the
enclosure. A standard breaker mounting screw kit for tapped
holes is furnished with each mechanism to mount the breaker in
the enclosure.
See page 6-95 for ordering information.

6-94 BuyLog Catalog www.geindustrial.com Rev. 7/13


Data subject to change
without notice
Molded Case Circuit Breakers Section 6
External Accessories
Cable Operators

How to Order
Use the circuit breaker mounting zone dimension table to determine the correct cable
length for the application and ensure that the 3-inch minimum bending radius is not
violated. Select the breaker mounted mechanism, operating cable and handle mecha-
nism below. Order as separate components.

Publication References
Breaker types E150, SE150, SF250, SG600 GEH-6290
Breaker type SK1200 GEH-6291

See Section 28 for publication ordering information.

Maximum Dimensions in Inches


To determine the maximum mounting dimensions for 60-through 120-inch-long
operating cables, add the respective additional lengths to the 48-inch cable maximum
dimensions. (Example: Add 12 inches to E, F and G dimensions for 60-inch cable length.) Circuit Breaker Mounting Zone
When cable is installed, the minimum cable bend radius should not be less than 3 Dimensions
inches. The minimum cable bending requirement must be met to ensure a safe
operating environment.

Maximum Mounting Dimensions (in.) Operating Cables


Box 36" Cable 48" Cable Circuit Breaker Type
Depth E1 F G E1 F G E150, SE150, SF250, SG600 SK1200
8" 13.5 4.0 15.0 25.5 16.0 27.0 Cable Product Product
Length Number Number
10" 13.0 5.0 14.8 25.0 17.0 26.8
12" 12.8 6.0 14.5 24.8 17.0 26.5 3' SC3L SC3H
16" 10.5 4.5 14.2 22.5 16.5 26.2 4' SC4L SC4H
18" 8.5 3.5 12.6 20.5 15.5 24.6 5' SC5L SC5H
20" 0.5 10.0 22.0 15.0 24.0 6' SC6L SC6H
24" 19.5 14.0 22.0 8' SC8L SC8H
1Maximum E Dimension only if F = 4.5" 10' SC10L SC10H

Breaker and Handle Mechanisms


Flange-Mounted Handle Mechanism
Breaker Mounted NEMA Enclosure Type 1, 3R, 12, 13 NEMA Enclosure Type 4, 4X
Circuit Mechanism 6" 10" 6" 10"
Breaker Product Product Product Product Product
Type Number Number Number Number Number
E150 SCOM1A
SE150 SCOM1EF
SCH1 SCH2 SCH1X SCH2X
SF250 SCOM1EF
SG600 SCOM1G
SK1200 SCOM1K SCH2K SCH2KX

Rev. 7/13 www.geindustrial.com BuyLog Catalog 6-95


Data subject to change
without notice
Molded Case Circuit Breakers Section 6
External Accessories
Flange-Mounted Operators

Type STDA Flange Handles and Variable Depth Operating Flange Stiffener Kit or Extended Length Drive Rod,
Mechanisms Product Number TDSR
Designed to meet automotive duty specifications Provides rigid 3/8-inch diameter rod between STDA handle mount-
NEMA 12/13 and 4/4X UL Component Recognized components, ing surface (flange or center mullion) and operating mechanism
File E-57253l CSA LR 10263 when STDA handle would otherwise not be rigidly supported.
For right or left hand flange mounting field convertible
Mounting dimensions to fit standard flange enclosures 8 inches Rod length is 22 inches and my be cut to appropriate length. Also
24 inches deep used as extended-length drive rod for SDOM1A and SDOM3 when
Detailed installation instructions standard 16 inch rod is not long enough. (Operating mechanism
Superior strength Product Number SDOM6 for SK1200 includes two 22" unique
3/8-16x22 inch flange stiffener rods, Product Number TDSR and
drive rod.)
Flange Handle Construction
Rugged die cast housing with provisions for locking in OFF Operating Flange Extended
position with up to three 3/16-inch to 5/16-inch padlocks Mechanism Stiffener Kit Drive Rod
Product Number Product Number Product Number
O-ring seals for dirt-tight/oil-tight duty SDOM1A, SDOM3,
Gusseted, 3/32-inch thick double-sided steel handle with large, TDOM1A through TDOM3
TDSR TDSR

red-black self-extinguishing grade plastic grip. TDSR


SDOM4,
(16" supplied with TDSR1
TDOM4 through TDOM7
Flange Handle Selection operating mechanism)

Product Number STDA1 (6 inch) and STDA2 (10 inch) flange series
handles are interchangeable. While the SE150 through SG600 Extended Drive Stud, Product Number TDS1, TDS2
operating mechanisms can be easily operated with the 6-inch
STDA1 handle, the 10-inch STDA2 may be used to obtain lower This optional drive study permits locating the operating mecha-
operating force and/or to provide a proportionally larger handle nism 1-5/16 inches farther to the left (When flange handle is on
on large enclosures. STDA3 and STDA3X can be used only with right side) or to the right (when handle is on the left side) to
SDOM6 (for SK1200) operating mechanism. accommodate specific mounting restrictions. Not suitable for use
with SDOM4, SDOM6, TDOM4 and TDOM5 operating mechanisms.
NEMA 12/13 NEMA 4/4X Nominal Installation Drilling
Flange Handle Flange Handle Length Instruction Template Operating Mechanism Extended Drive Stud
Product Number Product Number Inches Number Number Product Number Product Number
STDA1 STDA1X 6 SDOM1A, SDOM3,
TDS1
STDA2 STDA2X 10 GEH-5314 GEH-5314 TDOM1A through TDOM3
STDA3 STDA3X 10 TDOM6, TDOM7 TDS2

Operating Mechanism Selection


Circuit Breaker Flange Handle Operating Mechanism Door Hardware NEMA 12/13 and 4/4X
Type Product Number Product Number
SE150 STDA1,
SDOM1A 1X (6 inch) SDOM1A Type TDV door hardware provides sealing and interlocking of
SF250 or
SDOM3 SDOM3
SG600 STDA2,
SDOM42X (10-inch) SDOM4
3/4-inch nominal door depth hinged on left or right. Interlocking
SK12001 STDA3, 3X SDOM61 design requires use of screwdriver to release. When used with an
TEB, TED, THED, TEC, TB1 SDOM1A STDA flange handle and operating mechanisms, disconnect or
TB1 and TEC with TECL SDOM1AP5
THLC1 (150A) TDOM1D
circuit breaker cannot be turned on unless door and door hard-
J-Frames, TJC STDA1, 1X (6 inch)
TDOM4
ware have been closed. For noninterlocking type, one bracket in
(400, 600A)2 or
kit is not used. Use of third point latch recommended for doors
TB4 (400A) TJH/TJL3 STDA2, 2X (10-inch)
(600A Max)
TDOM5 40 inches or longer.
TB6 (600A), TB8 (800A)
TDOM7
TKH/TKLD4 (1200A Max)
Door Hinged Door Hinged
1Requires STDA3 or STDA3X (10 inch, SK1200 only). on Left on Right
2Includes TJ/THJ/TJL. Description Product Number Product Number
3Use TDOM5 for TJH/TJL. NEMA 12/13 two point
TDV1 TDV1L
4Use TDOM7 for TKH/TKL. interlocking door hardware kit
5Adapter plate required to use SDOM1A on TB1 and TEC with TECL limiter. NEMA 4/4X two point
TDV1X
interlocking door hardware kit
Third point latch kit for above TDV3 TDV3L

6-96 BuyLog Catalog www.geindustrial.com Rev. 7/13


Data subject to change
without notice
Molded Case Circuit Breakers Section 6
External Accessories
Flange-Mounted Operators

Auxiliary Contact Kits


Available SPDT and DPDT and actuated by operating mechanism yoke.

When STDA Auxiliary Contact Kit


Used With handle is on SPDT DPDT
Operating Mechanism Right Left Product Product
Product Number Flange Flange Number Number
SDOM1A,
SDOM3
TDAS1L1 TDAS1L2
SDOM4
TDOM1A, JA
TDOM1B, JB
TDOM1C
TDAS1R1 TDAS1R2
TDOM1D
TDOM3
SDOM6
TDOM4 TDAS2L1
TDOM5
TDOM6
TDAS1R1 TDAS1R2
TDOM7

Publication References
Instructions:
Door Hardware GEH-5322
Auxiliary Contact Kit GEH-5323
Flange Stiffener Kit or Extended Length Drive Rod GEH-5324
Extended Drive Stud GEH-5325
Operating Mechanism:
SDOM1A through SDOM4, SDOM6 GEH-5684
TDOM1A through TDOM1D GEH-5315
TDOM3 GEH-5317
TDOM4 and TDOM5 GEH-5318
TDOM6 and TDOM7 GEH-5319

See Section 28 for publication ordering information.

Rev. 7/13 www.geindustrial.com BuyLog Catalog 6-97


Data subject to change
without notice
Molded Case Circuit Breakers Section 6
External Accessories
Door-Mounted Operators

TDM Operating Handle, Fixed or Adjustable Shaft

TDM Handle Operating Mechanisms, Door Mounted


Complete mechanism with handle UL listed, E-57253
Operating mechanism only, UL Component Recognized, E-57253
Complete Mechanism1 Operating Handle Only
with NEMA 1, 3R, 12 Handle Mechanism Only NEMA 1, 3R, 12 NEMA 4/4X
Breaker Box Depth Product Product Product Product
Type in Inches Number Number Number Number

TQD, THQD Extended Shaft TQDHM2 TQDOM22


4 5/16 - 14 5/16
Shallow Mount
TEFHM1 TEFOM1
4 3/16
TEB, TEC, TB1, Extended Shaft
TEFHM3 TEFOM3 TH1
TED, THED 5-1/8 - 5 7/32
5 1/8 - 5 13/16 TEFHM4 TEFOM4
5 1/8 - 15 TEFHM2 TEFOM2
Shallow Mount
TFKHM1 TFKOM1 THCH453,4
TFC, TFJ, 5 7/8
TFK, THFK Extended Shaft
TFKHM2 TFKOM22
6 7/8 - 15 1/2
Shallow Mount
TJC, TJD, TJJ, TJKHM1 TJKOM1
5 7/8
TJK, THJK,
Extended Shaft
TB4, TBC4 TJKHM2 TJKOM24
5 5/8 - 15 5/8
TH2
Shallow Mount
TKC, TKM, TKMHM1 TKMOM1
7 7/16
THKM, TB6,
Extended Shaft
TBC6, TB8, TBC8 TKMHM2 TKMOM24
7 1/32 - 17 5/16
4 3/16 SEFHM1 SEFOM1
SE150 (GEH-5611)5
6 1/8 - 15 SEFHM2 SEFOM22 TH1
5 7/8 SEFHM1 SEFOM1
SF250 (GEH-5611)5
7 3/4 - 15 1/2 SEFHM2 SEFOM22
THCH453,4
5 7/8 SGHM1 SGOM1
SG600 (GEH-5653)5
5 5/8 - 15 5/8 SGHM2 SGOM24 TH2
6 SKHM1 SKOM1
SK1200 (GEH-5612)5 7 SKHM2 SKOM24
1Handle assembly and operating mechanism separately packaged.
2For 15-inch long shaft order Product Number 788A831G10. For 20-inch long shaft order Product Number 788A831G20.
3Provides interlocking for J600, SG600 SK1200, and K1200 breakers when used with the extended shaft operating mechanism. For interlocking with E150/SE150, F225 and
SF250 order special shaft Product Number 788A832G1.
4For 15-inch long shaft order Product Number 788A832G2. For 20-inch long shaft order Product Number 788A832G5.
5Installation instructions publication number.
6MOD 1 is 7 7/16; MOD 2 is 8 3/32.
7MOD 1 is 7 3/16 - 17 3/16; MOD 2 is 7 15/16 - 17 15/16.

Handle Accessories for TDM Operating Mechanisms


Device Product Number
Replacement neoprene gaskets
for NEMA 1, 3R and 12 enclosures
Use with TH1 788A742P3
Use with TH2 788A742P4

6-98 BuyLog Catalog www.geindustrial.com Rev. 7/13


Data subject to change
without notice
Molded Case Circuit Breakers Section 6
External Accessories
Door-Mounted Operators

TDR Handle on TED Circuit Breaker

TDR Integral Handle Mechanism1 Suitable for NEMA 12 Applications2


Handle Door Ring - Interlock Catch Kit NEMA 12 Gasket Kit
Vertical Mounting Horizontal Mounting Ship Product Product
Breaker Type Product Number Product Number Weight Number Number
TEB, TEC, TB1-B, TED, THED TEFR1B TEFR1HB 173 SEFRDRCK SEFRGSK
TFC, TFJ, TFK, THFK TFKR1B TFKR1HB 223 343L483G5
TJD, TJC, TJJ, TJK, THJK, TB4, TBC4 TJR1B TJR1HB 5 343L483G2 SGRGSK
TKC, TKM, THKM, TB6, TB8, TBC6, TBC8 TKMR1B TKMR1HB 5 SKRDRCK SKRGSK
SE150, SF250 (GEH-5609)5 SEFR14 SEFR1H4 173 SEFRDRCK SEFRGSK
SG600 (GEH-5654)5 SGR1 SGR1H 5 SGRDRCK SGRGSK
SK1200 (GEH-5610)5 SKR1 SKR1H 5 SKRDRCK SKRGSK
1Not suitable for use with mine duty or heavy duty UVR breakers.
2Requires Gasket kit.
3Shipped 12 per pack.
4For F250 Frame also order adapter bracket, Product Number SFRAK, no charge when ordered with handle.
5Installation instructions publication number. See Section 28 for publication ordering information.

Rev. 7/13 www.geindustrial.com BuyLog Catalog 6-99


Data subject to change
without notice
Molded Case Circuit Breakers Section 6
External Accessories
Motor Operators and Plug-in Hardware

Motor Mounted Mechanism


UL Listed
Voltage
Vac Product Installation
Breaker Type 50/60 Hz Vdc Number Instructions
24 TEDMOMA8
TEB,1 TEC, TED,1
1203 TEDMOMA1
THED, TB1, THLC12
2404,5 TEDMOMA2
24 TJKMOMA8
TJC, TJJ, TJD, TJK,
120 125 TJKMOMA1
THJK, TB4, TBC4
2404,5 250 TJKMOMA2
120 125 SEMOM1
SE150 2404 SEMOM2 GEH-5613
24 SEMOM8
120 125 SFMOM1
SF250 2404 SFMOM2 GEH-5613
24 SFMOM8
120 125 SGMOM1 Motor Operated Mechanism
SG600 2404 250 SGMOM2 GEH-5657 on SF-Frame breaker
24 SGMOM8
120 125 SKMOM1
SK1200 2404 250 SKMOM2 GEH-5614
24 SKMOM8

Mounting Screw Kit for Motor-Operated Mechanism6


Breaker Type Mounting Screw Kit Product Number
TED, TB1 343L564G7
TFJ, TFK 343L564G1
TJJ, TJK, TB4 343L564G2
SG600 SGMSKMOM
TKM, TB6, TB8, SK 343L564G3
1For use on 3-pole breaker only.
2Motor-operated mechanisms must have Code Date 506 + or later for use with THLC1.
3TEDMOMA1 not rated at 50 hertz.
4Suitable for use at 208 Vac.
5Not UL listed.
6Required with plug-in mounting base assembly when used with motor-operating
mechanisms or TDR integral-handle kits. Furnished no charge when ordered with
mounting base.

6-100 BuyLog Catalog www.geindustrial.com Rev. 7/13


Data subject to change
without notice
Molded Case Circuit Breakers Section 6
External Accessories
Mechanical Interlocks and Locking Devices

Mechanical Interlocks Standard Padlocking Devices3


Breaker Type Device Product Number
These face-mounted interlocks prevent two adjacent breakers
TEY TEYPLD1
from being in the ON position at the same time. E150, TB1 TEFPLD1
F225 TFKPLD1
Face-mounted Adapter Kit Required when using handle
Spectra RMS Interlock operator (TDM) or motor operator. J600 Line TJKPLD1
Breaker Type Product Number Order separately. K1200 Line TKMPLD1
SE150, SF250 SEPLD5
SE150, SF250 SEFFMI SEFFMIAK1
SG600 SGPLD5
SG600 SGFMI SGFMIAK2
SK1200 SKPLD5
SK1200 SKFMI SKFMIAK

Handle-Locking, Handle-Extension Devices EUSERC ApprovedFactory Installed Only


Breaker Type Device Product Number Breaker Type Product Number

TEY Handle locking TEYLD1 E150 TEDPLD2


E150 Line Handle locking TLD3 SE150, SF2504 SEFPLD2
F225 Line, SG600 SGPLD2
Handle locking TFKLD1 J600 TJKPLD2
THLC2, 4
SE150, SF250 Handle locking SBD1 SK1200 SKPLD2
SK1200 Handle extension - replacement SKHDLEXT 1Not suitable with THCH45 handle.
2Compatible with motor operator only. Product Number SGFMI cannot be used with
the handle operator.
3Suitable for circuit breakers used in group mounted panelboard construction only
except for J600, K1200, SE150/SF250, SG600 and SK1200 which screw down to face
of breaker.
4Field installable.
5Suitable for padlocking in either ON or OFF position.

Rev. 7/13 www.geindustrial.com BuyLog Catalog 6-101


Data subject to change
without notice
Molded Case Circuit Breakers Section 6
External Accessories
Breaker Mounting Hardware and Kits

Breaker Mounting Screw Kits Back-Connected Line and Load Studs


Length,
Spectra RMS Kit Screw Size
Back of Breaker Product
Application Breaker Type Product Number (inches)
Breaker Type Amperes in Inches Std Pkg Number
SEMSK1 10-32x2 7/8 (std.)
SE150 50 2 25/32 (short) 1 TEF1
For use on mounting SEMSK3 8-32x2 7/8 (opt.)
E1502, TB12, 4 13/32 (long) 1 TEF2
plates with tapped SFGMSK1 12-24x3 3/4 (std.)
SF250 THLC12 150 3 13/32 (short) 1 TEF3
holes (4 screws SFMSK1 10-32x3 3/4 (opt.)
5 25/32 (long) 1 TEF4
and lockwashers) SG600 SFGMSK1 12-24x3 3/4
TFJ2, TFK2, 2 23/32 (short) 1 TFK1
SK1200 SKMSK1 5/16-18x1 1/4 225
THFK2 5 31/32 (long) 1 TFK2
SEMSK2 10-32x3 (std.)
SE150 K1200, 5 1/2 1 TKM11
For use on mounting SEMSK4 8-32x3 (opt.) 1200
TB6, TB8 8 1 TKM12
plates with clearance SFGMSK2 12-24x4 (std.)
SF250 2 25/32 (short) 1 TEF1
holes (4 screws, SFMSK2 10-32x4 (opt.) 50
4 13/32 (long) 1 TEF2
lockwashers and nuts) SG600 SFGMSK2 12-24x4 SE150
3 13/32 (short) 1 TEF3
SK1200 SKMSK2 5/16-18x1 3/4 150
5 25/32 (long) 1 TEF4
2 23/32 (short) 1 TFK1
SF250 250
5 31/32 (long) 1 TFK2
Breaker Mounting Screw Kits and Accessories 2 13/16 (short) 1 SGBCS1
SG600 600
6 1/16 (long) 1 SGBCS2
Application Breaker Type Product Number 5 1/2 1 TKM11
SK1200 1200
8 1 TKM12
Bolt-on Mounting Base TEY TEY3B1
1-pole E150 343L162G1 1Accepts up to 3 poles (any combination).
For use on mounting
2- and 3-pole E150 SEMSK4 2For proper clearance between poles, a short and long stud must be assembled
plates with clearance
F225 SFGMSK2
holes adjacent to each other.
K1200 SKMSK2 3Contains 24 mounting screws.
1-pole TE, E150 343L162G7
2- and 3-pole E150 SEMSK3
For use on mounting 2- and 3-pole TQD/THQD 343L184G18
plates with tapped holes F225 SFGMSK1
J600 343L162G11
K1200 SKMSK1
Cup washer 254V644P1
E150
(for mounting 1-pole breakers) (2 req'd per breaker)

6-102 BuyLog Catalog www.geindustrial.com Rev. 7/13


Data subject to change
without notice
Molded Case Circuit Breakers Section 6
External Accessories
Lugs and Associated Hardware

Breaker with Line and Load Studs


Lugs, Line Shields, Covers and Bus Connectors
Accessory Wire Range For Use With Product Number Description
Copper-Aluminum Lugs (1) #14-6 Cu, #12-2 Al TQC (15-60A) (Non DIN Rail) TQAL3 Single Lug
(1) #4-1/0 Cu-Al TQC (70-100A) TQAL4 Single Lug
TCAL25 Single Lug
(1) #4-300 kcmil Cu-Al TQD
TCALK325 3-Lug Kit
(1) #14-8 E150, THLC1, TB1, (15-30A) TCAL14 Single Lug
(1) #14-3 Cu, #12-1 Al E150, THLC1, TB1, (15-60A) TCAL12 Single Lug
(1) #6-2/0 Cu, #4-2/0 Al E150, THLC1, TB1, (70-90A) TCAL12A Single Lug
(1) #3-3/0 Cu, #1-3/0 Al E150, THLC1, TB1, (100-150A) TCAL15 Single Lug
TCAL24 Single Lug
(1) #4-300 kcmil Cu-Al F225
TCALK324 3-Lug Kit
(1) 6-600 kcmil or (2) 2/0-250 kcmil Cu-Al J400, TB4, J600 (Thru 400A), TJD TCAL43 Single Lug
TCAL63 Single Lug
(2) 4/0-350 kcmil Cu or (2) 300-500 kcmil Al J600 (450-600A)
TCALK363 3-Lug Kit
(1) 750 kcmil Cu-Al J400 TJD TCAL47 Single Lug
(1) 3/0-500 kcmil or (2) 3/0-250 kcmil Cu-Al TLB4, THLC4 TCLK43 Single Lug
(2) 1/0-250 kcmil or (1) #4-600 kcmil Cu-Al K1200, TB6 (300-400A) TCAL41 Single Lug
TCAL61 Single Lug
(2) 2/0-500 kcmil Cu-A K1200, TB6 (300-600A) TCALK261 2-Lug Kit w/ Wrench
TCALK361 3-Lug Kit w/ Wrench
TCAL811 Single Lug
(3) 3/0-500 kcmil Cu-Al K1200, TB8 (600-800A) TCALK2811 2-Lug Kit w/ Wrench
TCALK3811 3-Lug Kit w/ Wrench
TCAL911 Single Lug
(3) 3/0-500 kcmil Cu-Al TK4V - Load end TCALK2911 2-Lug Kit w/ Wrench
TCALK3911 3-Lug Kit w/ Wrench
TCAL1212 Single Lug
(4) 250-350 kcmil Cu or (4) 250-500 kcmil Al K1200 (1000-1200A) TCALK21212 2-Lug Kit w/ Wrench
TCALK31212 3-Lug Kit w/ Wrench
TCAL1223 Single Lug
(3) 750 kcmil Cu-Al K1200 (1200A) TCALK21223 2-Lug Kit w/ Wrench
TCALK31223 3-Lug Kit w/ Wrench
(4) 250-350 kcmil Cu or (4) 250-500 kcmil Al TK4V - Load end TCAL1312 Single Lug
Copper Only Lugs #14-2/0 E150, TB1 (thru 150A) TC012 Single Lug
With Follower and Extra Plating #4-300 kcmil Cu TFJ (250A) TC024 Single Lug
(1) 6-600 kcmil or (2) 1/0-250 kcmil Cu J400, TB4 TC043 Single Lug
(2) 250-350 kcmil Cu J600 TC063 Single Lug
(1) 1/0-600 kcmil or (2) 1/0-250 kcmil Cu K1200, TB6 (300-400A) TC0414 Single Lug
(2) 2/0-500 kcmil Cu K1200, TB6, (300-600A) TC061 Single Lug
(3) 3/0-500 kcmil Cu K1200, TB8 (600-800A) TC081A Single Lug
(3) 3/0-500 kcmil Cu TK4V - Load end TC091 Single Lug
(4) 250-400 kcmil Cu K1200 (1000-1200A) TC0121 Single Lug
(4) 250-400 kcmil Cu TK4V - Load end TC0131 Single Lug
Line Shield TEB, TEC, TED, THED TEDLS
TFJ, TFK, TFC TFKLS
TJJ, TJK, TJC TJKLS
Lug Cover, TKM Breaker TC061, TCAL61, TCAL81 Lugs, TC081A 789A448G1
(two per breaker) TC0121; TCAL121 Lugs 789A448G2
Connector (back strap) TKM TKMC1
Line voltage control wire kit
K1200 SKLVK6
for terminating control wire at breaker lugs
1Not suitable for 100 A aluminum conductor.
2Suitable for 500 kcmil copper for voltage drop considerations.
3Not UL listed, requires user supplied lug cover.
4Not UL listed.
5End cover supplied with 800A frame is used as lug cover.
63-pole kit.

Rev. 7/13 www.geindustrial.com BuyLog Catalog 6-103


Data subject to change
without notice
Page Updated 09 / 2016
Molded Case Circuit Breakers Section 6
External Accessories
Lugs and Associated Hardware

Spectra RMS Lugs, Lug Covers, and Bus Lugs


Wire Range (Qty.)
Accessory For Use With Copper Aluminum Product Number Description Ampacity Range1
TCAL18 Single lug 15-150
SE150 (1) #12-3/0 (1) #12-3/0
TCALK318 3-lug kit 15-150
TCAL29 Single lug 70-250
SF250 (1) #8-350 kcmil (1) #8-350 kcmil
TCALK329 3-lug kit 70-250
(2) 2/0-500 kcmil or (2) 2/0-500 kcmil or TCLK2652 2-pole lug kit2 125-600
SG600
(1) #8-600 kcmil (1) #8-600 kcmil TCLK3652 3-pole lug kit2 125-600
Cu 275-1200
TCAL124 Single lug
Al 225-1100
Plated extruded aluminum
Cu 275-1200
lugs for terminating (3) 350-750 kcmil (3) 350-750 kcmil TCALK2124 2-lug kit w/wrench
Al 225-1100
copper or aluminum cables
Cu 275-1200
TCALK3124 3-lug kit w/wrench
Al 225-1100
TCAL81 Single lug 300-800
SK1200
(3) 3/0-500 kcmil (3) 3/0-500 kcmil TCALK281 2-lug kit w/wrench 300-800
TCALK381 3-lug kit w/wrench 300-800
TCAL125 Single lug 600-1200
(4) 250-500 kcmil (4) 250-500 kcmil TCALK2125 2-lug kit w/wrench 600-1200
TCALK3125 3-lug kit w/wrench 600-1200
Three lug covers for
SE150 SE3LCK
upper (line) end
SE150 Lug
SE150 SE3LCKL Cover Kit (Mod
For SEFR1 Handle)
Three lug covers for
SF250 SF3LCK
upper (line) end
Replacement Lug Covers 3-pole lug cover for
SG1LCK
and End Covers upper (line) or lower (load) end
SG600
3-pole lug cover for
SG1BCK4
upper (line) or lower (load) end4
Lug cover for upper (line)
SK1200 SK1LCK3
or lower (load) end3
SE150 (1) #12-3/0 TC018 Single lug 15-150
SF250 (1) #8-350 kcmil TCO29 Single lug 70-250
(2) 2/0-500 kcmil or TCOK265 2-pole lug kit 125-600
SG600
Plated Copper Lugs (1) #8-600 kcmil TCOK365 3-pole lug kit 125-600
(3) 250-500 kcmil TC081A Single lug 300-800
SK1200 (4) 250-400 kcmil TC0121 Single lug 600-1200
(3) 350-750 kcmil TCO124 Single lug 600-1200
(4) 250-500 kcmil TCO125 Single lug 600-1200
Single lug with .25
SE150 (1) #12-3/0 (1) #12-3/0 TCAL18LV 15-150
Line voltage control wire kit Quick Connect
SF250 (1) #8-350 kcmil (1) #8-350 kcmil TCAL29LV 70-250
for terminating control wire for Control Voltage
at breaker lugs SG600 SGLVK Single .25 Quick Connect
SK1200 SKLVK Single .25 Quick Connect
For MicroVersaTrip Plus and PM trip units
SPCOV1 Replacement cover
SPCOV2 Cover with access to instantaneous set point
Clear rating plug cover
SG600 / SK1200 SPCOV3 Cover with no access to instantaneous set point
with provision for wire seal
For microEntelliGuard Trip Units
SPCOV1C Replacement cover
SPCOV3C Cover with no access
1Both copper and aluminum cables may not cover full ampacity range.
2With lug cover for line or load end.
3100kA, 480 Vac (SKPA) uses longer lug cover/arc shield on upper end. Use Product Number SKPSHLD for replacement. May be used on other SK1200 devices.
4Required for line end bus connection.

6-104 BuyLog Catalog www.geindustrial.com Rev. 7/13


Data subject to change
without notice
Molded Case Circuit Breakers Section 6
External Accessories
Neutral Grounds and Sensors

Power Distribution Lugs


Breaker Max Wire Product
Type Amperes Range Number Description
TCAL19PD1 Power Distribution Lug
(2) 4-14 or
SE1, TED 125 3-Lug Power
(1) 2/0-4 Cu only TCAL19PD3
Distribution Lug Kit
TCAL28PD1 Power Distribution Lug
SF 250 (6) 4-14 Cu only 3-Lug Power
TCAL28PD3
Distribution Lug Kit
TCAL40PD1 Power Distribution Lug
SG 400 (12) 4-14 Cu only 3-Lug Power
TCAL40PD3
Distribution Lug Kit
1Lug barrier supplied is only suitable for the load/bottom side of the breaker. Power Distribution Lugs

Neutral Current Sensors


For grounded neutral system ground fault applications
Breaker Type Ampere Rating Product Number
150 TSRG201
200 TSRG202
300 TSRG203
J
400 TSRG204
500 TSRG205
600 TSRG206
800 TSKG408
K 1000 TSKG410
1200 TSKG412

Rating Plug Removal Tool Neutral Current Sensor

Product Number
TRTOOL

"Naval Use" Molded Case Circuit Breakers


The following molded case circuit breaker types are optionally
available as UL listed per Standard 489, Supplement SB for
naval use:
THQB
THQC
SE150
SF250
SG600
SK1200
Contact GE sales office for price and delivery.

Special Calibration
Contact GE sales office for availability. May void UL listing status.

Rev. 7/13 www.geindustrial.com BuyLog Catalog 6-105


Data subject to change
without notice
Molded Case Circuit Breakers Section 6
External Accessories
Plug-in Hardware

Each plug-in mounting base assembly includes all mounting


hardware, studs, and male or female connectors for attachment
to one end of breaker. Studs are of different length so by using
proper combinations of PD1 and PD2 units, adequate electrical
spacing will be assured between adjacent breakers, i.e., a short-
long-short (SLS) unit must be used adjacent to a long-short-long
(LSL) unit. Two-pole breakers of the E150 line require an open-
long-short (OLS) unit on one end of the breaker and a short-long-
open (SLO) on the other since these breakers are built with the
normal left pole missing while the mounting bases are built from Plug-in Mounting Base with Hardware
standard three-pole molded supports. Product Number TF23PD2 shown
Spectra RMS and all other two-pole breakers are basically three-
pole devices with the center pole omitted. When these breakers
are to be mounted side by side, a short-open-short (SOS) unit
must be used on one end and a long-open-long (LOL) on the other.
Horizontal studs are normally supplied with the flat surface of
studs at right angles to the long axis of the breaker. If vertical
studs are desired, substitute "C" for "D" in the product number,
e.g., TE13PC1 (vertical) or TE13PD1 (horizontal).
The optional mounting plate (TMP1, etc.) accurately locates and
supports the pair of line and load plug-in mounting-base assem-
blies and provides a convenient means to attach the entire unit to
a metal structure, and serves as a dead front barrier. New draw-
ings are available for customers who prefer to fabricate their own Plug-in Mounting Base
mounting plates. Product Number TK123PD2A shown

Plug-In Mounting Base Assembly


Plug-In Mounting Bases - 2 Required Per Breaker Optional Mounting Base
Ampere Breaker Stud Configuration Product Product
Rating Type No. Poles PD1 PD2 Number Number
E1501 2 OLS SLO TE12PD1,2 TMP1
150
SE150 3 SLS LSL TE13PD1,2 TMP1
2 SOS LOL TF22PD1,2 TMP2
250 SF250 3 SLS LSL TF23PD1,2 TMP2
3 SLS LSL TF23PC1 TMP2
2 SOS LOL TJ42PD1A,2A TMP3
400 J400 3 SLS LSL TJ43PD1A,2A TMP3
3 SLS LSL TJ43PC1A TMP3
SG400 3 SLS2 LSL2 SGPC1, SGPC2 SMP3
2 SOS LOL TJ62PD1A,2A TMP3
J600 3 SLS LSL TJ63PD1A,2A TMP3
600
3 SLS LSL TJ63PC1A TMP3
SG600 3 SLS2 LSL2 SGPC7 SMP3
3 SLS LSL TK83PD1A,2A TMP4
800 SK800
3 SLS LSL TK83PC1A,2A TMP4
3 SLS LSL TK103PD1A,2A TMP4
1000 SK1200
3 SLS LSL TK103PC1A,2A TMP4
3 SLS LSL TK123PD1A,2A TMP4
1200 SK1200
3 SLS LSL TK123PC1A,2A TMP4
1Order 3-pole base for use with 2-pole Hi Break and 600 Vac breakers.
2Vertical studs only for SG600 frame.

6-106 BuyLog Catalog www.geindustrial.com Rev. 7/13


Data subject to change
without notice
Section Updated 01 / 2016
Circuit Breaker Enclosures Section 7

NEMA Type 1 Enclosures .............................................................7-2


NEMA Type 3R Enclosures...........................................................7-3
NEMA Type 12 Enclosures ...........................................................7-4
NEMA Type 4/4X Enclosures .......................................................7-5
Hubs and Other Accessories ......................................................7-6
Dimensions and Outline Drawings............................................7-7
Dimensions and Knockout Drawings........................................7-8

Rev. 11/13 www.geindustrial.com BuyLog Catalog 7-1


Data subject to change
without notice
Circuit Breaker Enclosures Section 7
NEMA Type 1

Suitable for use as service equipment (SE) as noted.


60C/75C conductor ratings
Short circuit ratings are equal to the rating of the
installed breaker.

To order enclosed or accessorized circuit breakers, a configurator is available at:


www.geelitenet.com (EliteNet)
Type 1, Indoor Surface or Flush Mounting

NEMA Type 1
For Enclosures with
Certifications Product Number Suffix Options (Mounting) For 3P4W Enclosures Ground Fault Protection
Max. Surface,
Ampere No. of UL cUL Blank Neutral Neutral Product Neutral Sensor
Rating Frame Type Poles SE cUL SE1 CSA Prefix Flush Surface End Wall2 Product Number Number3 for Ground Fault
70 THQL, TXQL, THQL-GF 1, 2, 3 TQL70_4 F S Included
100 THQL, TXQL, THQL-GF 1, 2, 3 TQL100_4 F S Included
125 THQL 2 TQL125_ F S Included
100 THQC, THHQC, TXQC 1, 2, 3 TQC100_4 F S Included
100 SE150, THED, TED, TEB 2, 3 TE100_ F S SB Included
150 SE150, THED, TED 2, 3 TE150_ F S SB Included
225 TQD, THQD 2, 3 TQD225_ F S - Included
250 SF250 2, 3 SF250_ F S SB TNIA2255
FEGS0025
FEGS0060
250 FE250 2, 3 FE250_ F S SB TNIA2255 TNIA250EGF FEGS0125
FEGS0150
FEGS0250
400 TJD, TJJ, TJK, THJK 2, 3 TJ400_6 F S - TNIA400
600 TJK, THJK 2, 3 TJ600_ F S - TNIA600
TSRG201
400 SG400 2, 3 SG400_ F S SB TNIA400 TNIA400VG
TSRG204
600 SG600 2, 3 SG600_ F S SB TNIA600 TNIA600VG TSRG206
FGGS0250
600 FG600 2, 3 FG600_ F S SB TNIA400 TNIA400GGF
FGGS0400
TNIA600
TNIA600GGF FGGS0600
TNIA400
TNIA600 TNIA800G TSKG408
1200 SK1200 2, 3 TK4V1200_7, 8 F S SB TNIA800 TSKG410
TNIA1200G
TNIA1200 TSKG412
TNIAC1200
1 cUL Listed - Suitable for use as service equipment.
2 Enclosures with blank end walls feature closed enclosure instantaneous adjustment.
3 Neutral for ground fault required to mount neutral sensor in enclosure.
4 3-Pole breakers with an accessory cannot be installed in these enclosures.
5 For 250A rating, use copper cable only.
6 Suitable for parallel 250 kcmil maximum. If larger cable is required, use 600A enclosure.
7 Not suitable for 100% rated 1200A SK breakers.
8 Suitable for parallel 500 kcmil maximum.

7-2 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Circuit Breaker Enclosures Section 7
NEMA Type 3R

Suitable for use as service equipment (SE) as noted.


60C/75C conductor ratings
Short circuit ratings are equal to the rating of the
installed breaker.

To order enclosed or accessorized circuit breakers, a configurator is available at:


www.geelitenet.com (EliteNet)
Type 3R, Outdoor, Raintight

NEMA Type 3R
For Enclosures with
Max. Certifications For 3P4W Enclosures Ground Fault Protection
Ampere No. of UL cUL Product Neutral Neutral Neutral Sensor
Rating Frame Type Poles SE cUL SE1 CSA Number10 Product Number Product Number2 for Ground Fault
70 THQL, TXQL, THQL-GF 1, 2, 3 TQL70R3 Included
100 THQL, TXQL, THQL-GF 1, 2, 3 TQL100R3 Included
125 THQL 2 TQL125R Included
100 THQC, THHQC, TXQC 1, 2, 3 TQC100R3 Included
100 SE150, THED, TED, TEB 2, 3 TE100R Included
150 SE150, THED, TED 2, 3 TE150R Included
225 TQD, THQD 2 TQD225NR9 Included
225 TQD, THQD 2, 3 TQD225R Included
250 SF250 2, 3 TF225R TNIA2254
FEGS0025
FEGS0060
250 FE250 2, 3 FE250R TNIA2254 TNIA250EGF FEGS0125
FEGS0150
FEGS0250
400 TJD, TJJ, TJK, THJK 2, 3 TJ400R5 TNIA400
600 TJK, THJK 2, 3 TJ600R TNIA600
TSRG201
400 SG400 2, 3 SG400R TNIA400 TNIA400VG
TSRG204
600 SG600 2, 3 SG600R TNIA600 TNIA600VG TSRG206
TNIA400 FGGS0250
TNIA400GGF
600 FG600 2, 3 FG600R TNIA600 FGGS0400
TNIA600GGF FGGS0600
TNIA400
TNIA600 TNIA800G TSKG408
1200 SK1200 2, 3 TK4V1200R6, 7 TNIA800 TSKG410
TNIA1200G
TNIA1200 TSKG412
TNIAC1200

Max. Certifications For 3P4W Enclosures


Ampere No. of UL cUL Product Neutral
Rating Frame Type Poles SE cUL SE1 CSA Number10 Product Number Notes
100 THQL, TXQL, THQL-GF 1, 2, 3 TQL70RE3 Included 100A circuit breaker factory installed (2-pole)
150 TQD, THQD 2 TQD150NRE Included 150A circuit breaker factory installed (2-pole)
200 TQD, THQD 2 TQD200NRE Included 200A circuit breaker factory installed (2-pole)
150 THQMV 2 THQMV150NRE8 Included 150A circuit breaker factory installed (2-pole)
200 THQMV 2 THQMV200NRE8 Included 200A circuit breaker factory installed (2-pole)
1 cUL Listed - Suitable for use as service equipment.
2 Neutral for ground fault required to mount neutral sensor in enclosure.
3 3-Pole breakers with an accessory can not be installed in these enclosures.
4 For 250A rating, use copper cable only.
5 Suitable for parallel 250 kcmil maximum. If larger cable is required, use 600A enclosure.
6 Not suitable for 100% rated 1200A SK breakers.
7 Suitable for parallel 500 kcmil maximum.
8 Service rated equipment only.
9 TQD225NR is 2P only and differs in size from TQD225R.
10100-250A devices have removable closing cap. Larger ampere devices require field cut openings. Order hubs separately. See page 7-6.

Rev. 11/13 www.geindustrial.com BuyLog Catalog 7-3


Data subject to change
without notice
Circuit Breaker Enclosures Section 7
NEMA Type 12

Suitable for use as service equipment (SE) as noted.


60C/75C conductor ratings
Short circuit ratings are equal to the rating of the
installed breaker.

To order enclosed or accessorized circuit breakers, a configurator is available at:


www.geelitenet.com (EliteNet) Types 12K and 12,
Rotary Handle Integral with Breaker

NEMA Type 12
For Enclosures with
Max. Certifications Product Number Suffix Options (Mounting) For 3P4W Enclosures Ground Fault Protection
Ampere No. of cUL With Knock Without Neutral Neutral Product Neutral Sensor
Rating Frame Type Poles UL cUL SE1 CSA Prefix Outs Knock Outs Product Number Number2 for Ground Fault
100 THED, TED, TEB 3 TE100_ D J Included
100 SE150 2, 3 SE100_ D J Included
250 SF250 2, 3 SF250_ D J TNIA2254
400 TJD, TJJ, TJK, THJK 2, 3 TJ400_3 J TNIA400
TNIA400
600 TJK, THJK 2, 3 TJ600_ J
TNIA600
TSRG201
400 SG400 2, 3 SG400_ D J TNIA400 TNIA400VG
TSRG204
600 SG600 2, 3 SG600_ J TNIA600 TNIA600VG TSRG206
TNIA400
TNIA600 TNIA800G TSKG408
1200 SK1200 2, 3 SK1200_5, 6 J TNIA800 TSKG410
TNIA1200G
TNIA1200 TSKG412
TNIAC1200
1 cUL Listed - Suitable for use as service equipment.
2 Neutral for ground fault required to mount neutral sensor in enclosure.
3 Suitable for parallel 250 kcmil maximum. If larger cable is required, use 600A enclosure.
4 For 250A rating, use copper cable only.
5 Not suitable for 100% rated 1200A SK breakers.
6 Suitable for parallel 500 kcmil maximum.

7-4 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Page Updated 01 / 2016
Circuit Breaker Enclosures Section 7
NEMA Type 4/4X

Suitable for use as service equipment (SE) as noted.


60C/75C conductor ratings
Short circuit ratings are equal to the rating of the
installed breaker.

To order enclosed or accessorized circuit breakers, a configurator is available at:


www.geelitenet.com (EliteNet) Types 4/4X,
Stainless Steel, Watertight , Dust Tight

NEMA Type 4/4X


For Enclosures with
Max. Certifications For 3P4W Enclosures Ground Fault Protection
Ampere No. of UL cUL Product Neutral Neutral Neutral Sensor
Rating Frame Type Poles SE cUL SE1 CSA Number Product Number Product Number2 for Ground Fault
100 THED, TED, TEB 2, 3 TE100CS TNI100
100 SE150 2, 3 SE150CS TNI100
250 SF250 2, 3 SF250CS TNIA2253
400 TJD, TJJ, TJK, THJK 2, 3 TJ400CS4 TNIA400
TNIA400
600 TJK, THJK 2, 3 TJ600CS
TNIA600
400 SG400 2, 3 SG400CS5 TNIA400
1 cUL Listed - Suitable for use as service equipment.
2 Neutral for ground fault required to mount neutral sensor in enclosure.
3 For 250A rating, use copper cable only.
4 Suitable for parallel 250 kcmil maximum. If larger cable is required, use 600A enclosure.
5 Not suitable for 3-Phase, 4-wire or Single-Phase, 4 wire ground fault applications that require Neutral sensor mounted in enclosure.

Rev. 11/13 www.geindustrial.com BuyLog Catalog 7-5


Data subject to change
without notice
Circuit Breaker Enclosures Section 7
Hubs and Other Accessories

Universal Raintight Hubs, Aluminum


For outdoor enclosures that have removable closing caps.
Nominal Conduit Diameter (in.) Standard Package Product Number
3/4 10 TC75
1 10 TC100
1 1/4 10 TC125
1 1/2 10 TC150
2 10 TC200
2 1/2 10 TC250
3 5 TC300
Closing Cap 10 TCCP

TC150

Stainless Steel Cover


For flush mounted Type 1 circuit breaker enclosures, field installed only.
For Use with Product Number
TE100F TE100FSS

Insulated Groundable Neutrals

Max. Ampere Rating Lug Wire Size (Cu-Al) AWG/kcmil Standard Package Product Number
100 14-1/0 Cu, 12-1/0Al 1 TNI100
225 1-300 1 TNIA2251
250 1-300 1 TNIA250EGF1, 3
400 (2) 1/0-250 or (1) 4-600 1 TNIA400
400 (2) 1/0-250 or (1) 4-600 1 TNIA400VG2
400 (2) 1/0-250 or (1) 4-600 1 TNIA400GGF3
600 (2) 2/0-500 1 TNIA600
600 (2) 2/0-500 1 TNIA600VG2
600 (2) 2/0-500 1 TNIA600GGF3
800 (3) 250-500 1 TNIA800
800 (3) 250-350 Cu or (3) 250-500 Al 1 TNIA800G2
1200 (4) 250-350 Cu or (4) 250-500 Al 1 TNIA1200
1200 (4) 250-350 Cu or (4) 250-500 Al 1 TNIA1200G2
1200 (4) 250-400 Cu Only 1 TNIAC1200
1For 250A rating, use copper cable only
2Neutral required for Spectra Circuit Breakers with ground fault.
3Neutral required for Record Plus Circuit Breakers with ground fault.

Ground Kits

Ampere Rating Product Number


70-125 amp TGL1
(1) TGL1 plus
150-400 amp
(1) TGL20
600-1200 amp TGL6

7-6 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Circuit Breaker Enclosures Section 7
Dimensions and Outline Drawings

NEMA Type 1 Enclosures


Product Dimension1 Dimension1 Dimension1 Dimension Dimension Outline
Number A (in.) B (in.) C (in.) D (in.) E (in.) Drawing No.
TE100F, S, SB4 17 7 7/8 5 1/2 4 3/4 208C2891 Sh 3
TE150F, S, SB4 26 7/16 8 7/8 8 7/8 6 3/16 5 1/2 139C5497 Sh 1
SF250F, S, SB4 29 7/8 8 7/8 8 7/8 6 3/16 5 1/2 139C5497 Sh 2
FE250F, S, SB4 26 7/16 8 7/8 8 7/8 6 3/16 5 1/2 139C5497 Sh 9
SG400F 31 3/8 15 5/32 7 5/16 6 5/8 208C2891 Sh 1
SG400S, SB4 30 5/16 14 1/8 7 5/16 6 5/8 208C2891 Sh 1
TJ400F, S2 27 7/16 15 7/16 15 7/16 7 1/8 6 7/16 139C5497 Sh 3
SG600F 44 18 3/16 9 8 3/8 208C2891 Sh 2
SG600S, SB4 42 3/4 17 1/8 9 8 3/8 208C2891 Sh 2
FG600F, S, SB4 42 3/4 17 1/8 9 8 3/8 208C2891 Sh 7
TJ600F, S 46 5/8 17 3/16 17 3/16 9 1/16 8 3/8 139C5497 Sh 4
TK4V1200F, S, SB4 48 1/8 21 15/16 21 15/16 9 9/16 8 11/16 139C5497 Sh 5
TQC100F, S 15 1/4 6 7/8 4 3/4 4 139C5651 Sh 1
TQD225F, S 26 7/16 8 7/8 8 7/8 6 3/16 5 1/2 139C5497 Sh 1 NEMA Type 1
TQL70F, S 12 7/8 5 3/4 4 3/4 4 1/16 208C2817 Sh 1
TQL100F, S 15 1/4 6 7/8 4 3/4 4 139C5651 Sh 2
Suffix F (Flush) Suffix S (Surface)
TQL125F, S 16 7/8 6 3/4 5 3/16 4 1/2 139C5651 Sh 2

NEMA Type 3R Enclosures


Product Dimension Dimension Dimension Dimension Dimension Outline
Number A (in.) B (in.) C (in.) D (in.) E (in.) Drawing No.
TE100R 18 1/8 7 7/8 7 1/2 5 11/16 5 3/8 139C5652 Sh 1
TE150R 27 7/16 10 1/4 10 6 1/4 5 1/2 139C5498 Sh 1
TF225R 30 13/16 10 1/4 10 7 6 1/4 139C5498 Sh 2
FE250R 27 7/16 10 1/4 10 6 1/4 5 1/2 139C5498 Sh 5
SG400R 30 13/16 14 15/16 14 5/8 9 1/8 8 208C2837 Sh 1
SG600R 43 18 7/8 18 1/6 8 13/16 7 11/16 208C2838 Sh 1
FG600R 43 18 7/8 18 1/6 8 13/16 7 11/16 208C2838 Sh 2
TJ400R2 27 5/16 15 7/8 15 11/16 8 11/16 8 139C5498 Sh 4
TJ600R 46 3/16 18 1/16 18 1/16 8 5/8 7 5/8 139C5519 Sh 1
TK4V1200R 47 3/4 23 3/8 22 9/16 9 7/16 8 5/16 139C5520 Sh 1
TQC100R 15 3/4 7 7/8 7 1/2 5 11/16 5 3/8 139C5652 Sh 1
TQD150NRE 26 13/16 7 13/16 7 5/8 5 1/8 4 7/16 139C5498 Sh 3
TQD200NRE 26 13/16 7 13/16 7 5/8 5 1/8 4 7/16 139C5498 Sh 3
TQD225NR 26 13/16 7 13/16 7 5/8 5 1/8 4 7/16 139C5498 Sh 3 NEMA Type 3R Outdoor Enclosure
TQD225R 26 3/8 10 1/4 10 6 1/4 5 1/2 139C5498 Sh 1
TQL70R 17 6 7/8 5 15/16 5 208C3061 Sh 1
TQL100R, RE 17 7 1/4 6 7/8 6 5 139C5652 Sh 1
TQL125R 18 5/16 7 11/16 7 1/2 6 5/16 5 3/16 139C5652 Sh 1
THQMV150NRE 18 13/16 9 1/2 9 5/16 5 1/2 4 7/8 208C3061 Sh 2
THQMV200NRE 18 13/16 9 1/2 9 5/16 5 1/2 4 7/8 208C3061 Sh 2

NEMA Type 4/4X Enclosures


Product Dimension Dimension Dimension Dimension Dimension Outline
Number A (in.) B (in.) C (in.) D (in.) E (in.) Drawing No.
SE100CS 19 1/4 18 1/2 8 1/2 7 5 139C5654 Sh 1
TE100CS 19 1/4 17 1/4 8 1/2 7 5 139C5654 Sh 1
SF250CS 36 5/8 34 13/16 9 1/4 7 27/32 5 29/32 168D1626 Sh 1
TJ400CS2 29 1/4 27 1/2 16 1/4 9 1/16 7 1/8 139C5496 Sh 2
SG400CS3 32 31 1/4 14 1/8 9 5/16 7 7/16 208C2887 Sh 1
TJ600CS 46 1/4 45 1/2 19 1/8 9 1/16 7 1/8 139C5496 Sh 3

NEMA Type 12 and 12K Enclosures


Product Dimension Dimension Dimension Dimension Dimension Dimension Outline
NEMA Type 4/4X Stainless Steel
Number A (in.) B (in.) C (in.) D (in.) E (in.) F (in.) Drawing No.
SE100J, D 19 1/4 17 7/8 9 5 5 3/4 4 7/8 139C5653 Sh 1
TE100J, D 19 1/4 17 7/8 9 5 5 3/4 4 7/8 139C5653 Sh 1
SF250D 36 1/4 35 3/8 9 13/16 9 3/16 7 9/16 6 1/2 208C2884 Sh 1
SF250J 36 1/4 35 3/8 9 13/16 9 3/16 7 9/16 6 1/2 208C2884 Sh 2
SG400D 31 3/8 30 1/2 16 5/16 15 11/16 7 7/8 6 9/16 208C2885 Sh 1
SG400J 31 3/8 30 1/2 16 5/16 15 11/16 7 7/8 6 9/16 208C2885 Sh 2
TJ400J2 29 5/16 27 13/16 14 1/4 13 3/16 7 7/8 6 7/16 139C5682 Sh 4
SG600J 44 7/8 44 18 17 3/8 9 9/16 8 3/8 208C2886 Sh 1
TJ600J 48 7/16 46 15/16 17 3/4 17 3/16 9 3/4 8 3/8 139C5682 Sh 5
SK1200J 56 5/16 55 7/16 22 11/16 22 10 7/16 8 11/16 139C5682 Sh 6
1Flush front extends approximately 5/8-inch beyond each side.
2Suitable for parallel 250 kcmil maximum. If larger cable is applied, use 600 amp enclosure.
3Not suitable for use with ground fault.
4NEMA Type 1 Enclosure Product Numbers ending in SB contain blank end walls (No Knockouts).

NEMA Type 12 and 12K


Suffix D (with KOs) Suffix J (without KOs)

Rev. 11/13 www.geindustrial.com BuyLog Catalog 7-7


Data subject to change
without notice
Circuit Breaker Enclosures Section 7
Dimensions and Knockout Drawings
Symbol A B C D E F G H I J K L M N P Q R S T U V W X Y Z
9/32 3/8 3/8
1/2 1/2 1/2 1/2 1/2 1/2
3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4

1 1 1 1 1 1 1 1 1 1 1
Conduit 11/4 11/4 11/4 11/4 11/4 11/4 11/4 11/4 11/4 11/4 11/4
Size
11/2 11/2 11/2 11/2 11/2 11/2 11/2 11/2 11/2 11/2 11/2
(Inches)
2 2 2 2 2 2 2 2 2 2 2
21/2 21/2 21/2 21/2 21/2 21/2 21/2 21/2
3 3 3 3 3 3 3
31/2 31/2 31/2 31/2 31/2
4

Circuit Breaker Enclosures


Product Number Knockout Figure No.
TE100F, S 1
TE100R 10
TE150F, S 4
TE150R 7
SF250F, S, FE250F, S 4
TF225R, FE250R 7
TJ400F, S, SG400F, S 5
TJ400R, SG400R 6
TJ600R, SG600R, FG600R 9
TJ600F, S, SG600F, S, FG600F, S 3 Fig. 1 Fig. 2
TK4V1200F, S No KO
TK4V1200R No KO
TQC100F, S 2
TQC100R 10
TQD225F, S 4
TQD225NR 8
TQD225R 7
TQL100F, S 2
TQL100R 10

Fig. 3 Fig. 4

Fig. 5 Fig. 6 Fig. 7

Fig. 8 Fig. 9 Fig. 10

7-8 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Section Updated 08 / 2016

Low Voltage Power & Insulated Case Circuit Breakers Section 8

Low Voltage Power and DC Circuit Breakers Insulated Case Circuit Breakers

EntelliGuard G Low Voltage Power Circuit Breakers ...........8-2 Power Break II ...........................................................................8-91
Overview and Functions ........................................................................8-2 Features .......................................................................................................8-91
EntelliGuard TU Trip Units....................................................................8-4 Construction Options .............................................................................8-92
Product Nomenclature ............................................................................8-5 EntelliGuard TU Trip Unit Features................................................8-93
Cassettes Nomenclature......................................................................8-11 Power+ Trip Unit Features...................................................................8-94
Accessories.................................................................................................8-13 Enhanced MicroVersaTrip Trip Unit Features ..........................8-95
WavePro Circuit Breakers with EntelliGuard TU, Trip Unit Characteristics .......................................................................8-96
Power+, Enhanced MicroVersaTrip Plus and Power Break II Nomenclature System ........................................8-99
MicroVersaTrip PM Trip Unit Systems ............................8-24 Product Number Nomenclature System ...................................8-104
WavePro Low Voltage Power Circuit Breakers .....................8-26 Interrupting Capacity and Withstand Ratings ........................8-108
OEM Substructures and Substructure Accessories .............8-40 How to Order...........................................................................................8-109
Trip Units......................................................................................8-49 Frame Selection (Old Structure) .....................................................8-110
Overview EntelliGuard TU, Power+ and Trip Unit Selection.................................................................................8-111
Enhanced MicroVersaTrip .............................................................8-49 Enhanced MicroVersaTrip Rating Plug Selection ................8-113
Product Number Nomenclature System ......................................8-55 Stationary and Draw-out Switch Selection ..............................8-114
Trip Unit Conversion Kits Introduction...................................8-66 Stationary and Draw-out Breaker Accessories ......................8-115
Overview EntelliGuard TU, and Stationary Breaker Mounting Kits .................................................8-121
MicroVersaTrip PM Conversion Kits...........................................8-67 Stationary Breaker Mounting Kits,
Remanufactured MVT Trip Unit Wall Mounted Enclosures, Floor Mounted Enclosures .....8-122
Overview and Features......................................................................8-69 Neutral Current Sensors and
ProTrip Trip Unit Conversion Kits Selection Guide.................8-70 POWER LEADER Accessories......................................................8-123
ProTrip Rating Plugs.............................................................................8-74 Draw-out Breaker Accessories.......................................................8-124
EntelliGuard TU Trip Unit Conversion Reference Publications............................................................8-126
Kits Selection Guide.............................................................................8-76
EntelliGuard TU Trip Rating Plugs..................................................8-80
EntelliGuard TU Trip Unit Conversion Kit
Accessories and Hardware ..............................................................8-81
Trip Unit Accessories..............................................................................8-83
Asbestos Free Arc Quencher Replacement Kits ...................8-85
Gerapid High Speed DC Circuit Breakers...............................8-86
Features and Benefits ...........................................................................8-86
Technical Data ..........................................................................................8-88
Outline Drawings and Dimensions..................................................8-89

Visit GE Industrial Solutions website for ordering low voltage power and insulated case circuit breakers and accessories at:
www.geindustrial.com/industrialsystems/wizards/peb_oem_am/home.htm

Rev. 11/13 www.geindustrial.com BuyLog Catalog 8-1


Data subject to change
without notice
Low Voltage Power & Insulated Case Circuit Breakers Section 8

EntelliGuard G Low Voltage Power Circuit Breaker
Overview and Functions

EntelliGuard G Circuit Breakers


EntelliGuard G Circuit Breakers are the newest top of the line
circuit breakers designed to meet the demands of todays
electrical distribution systems by providing ultimate system
performance without sacrificing safety or reliability. EntelliGuard
G devices are available in standard, 100% rated, ANSI/UL1066,
UL489 and IEC ratings. Breakers are offered to OEMs in 3 and 4
pole designs from 400A to 6000A (UL/ANSI) or up to 6300A (IEC)
with fault interruption ratings up to 150kA and many field-
installable accessories. EntelliGuard G 3-pole breakers are the
standard in GE AKD-20 Low Voltage Switchgear suitable for
280Vac and 600Vac. The breakers are suitable for 280Vac,
480Vac and 600Vac applications, and they provide advanced
circuit protection, limit arc fault energy and preserve system
coordination without sacrificing any of these critical functions.

Standard Functions
The EntelliGuard G Circuit Breakers offer operational safety with
functions such as:
Closing and opening - can be initiated remotely or via the front
cover push buttons. An Open-Close-Open cycle is possible with-
out recharging.
Breaker/Main Contact Status - OPEN/CLOSED, ON/OFF indication
is provided on the front cover.
Through-Door Racking - The breaker racking mechanism is Two-Step Stored Energy Mechanism - Breaker operates via
accessible through the front door and permits safely disconnect- stored energy mechanisms that can be manually charged (MO) or
ing/withdrawing the circuit breaker without opening the door and electrically charged (EO) by the Spring Charging Motor. Closing
exposing personnel to live parts during the process. time is less than five cycles.
Ready to Close Indicator - Provides visible indication/readiness Reverse Feed EntelliGuard G devices can be fed from top or
for close operation. bottom terminals.
Breaker Status Indicators - Standard Indicators include: Coils - EntelliGuard G devices have provisions for four accessory
The breaker status indicator shows the condition of the main operating coils. The four positions can be filled by the following
contacts (OPEN, CLOSED). four devices: one Close Coil (CC or CCC), one Shunt Trip Coil, one
The status of the closing springs is indicated as CHARGED UVR (Under Voltage Release), and the fourth position can either
or DISCHARGED. be a Shunt Trip Coil or a UVR.
The draw-out position indicator displays whether the breaker is Motor Operator Heavy Duty, Motor/Gearbox Unit -
in the CONNECT, TEST or DISCONNECT position. easily accessible.
The breaker also includes a switch that provides main
contact status indication to the POWER LEADER Power Interlocks - Standard interlocks include:
Management System. Drawout Breaker
The optional Reduced Energy Let-Through (RELT) is provided Drawout Breaker/Main Contacts
with an ON/OFF contact closure to positively indicate whether Spring Discharge Interlock
the RELT setting is enabled or not. Padlocking Devices - The padlocking device is standard on
Rejection Feature - A factory-installed rejection feature prevents breakers and allows up to three padlocks with 1/4" to 3/8" diame-
mismatching breakers and cassettes/substructures. ter shanks to secure the breaker in the OPEN/TRIP FREE position.
Thermal Performance - ANSI C37 and UL 489 designs are 100%
rated up to 40C when applied in recommended enclosure sizes.
EntelliGuard G breakers are designed for flexibility and IEC 60947 versions are 100% rated in free air up to 50C. IP31
superiority with functions such as: enclosure/switchboard rating is based on size, recommended up
Short Time Rating - Up to 100kA for 0.5 sec. to 50C ambient with rear vertical bus connection.
Short Circuit/High Interruption Rating - 150kA at 600V, Field Installable Trip Units and Accessories Field - installable
100kA at 690V. accessories are common to all breaker envelopes and frames.
Optionally, accessories are also factory mountable.

8-2 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Page Updated 08 / 2016

Low Voltage Power & Insulated Case Circuit Breakers Section 8



EntelliGuard G Low Voltage Power Circuit Breaker
Functions

Optional Functions EntelliGuard G circuit breakers with


EntelliGuard G Circuit Breakers offer many optional functions in EntelliGuard trip units can be part of
order to enhance and facilitate the use of the circuit an ArcWatch solution.
breaker. Those functions include: GEs ArcWatch system solution
involves a combination of intelligent
Auxiliary Switches - (Optional) Four available designs: trip units and current limiting molded
Power rated (3NO+3NC) case circuit breakers to create a no compromise solution; safety
Power rated (3NO+3NC) + low signal (Hi-Fi) (2NO+2NC) and reliability together. Advances in zone selective interlocking
Power rated (8NO+8NC) (ZSI) and waveform recognition algorithms allow entire systems to
Power rated (4NO+4NC) + low signal (Hi-Fi) (4NO+4NC) be designed so that full selectivity and 100% instantaneous pro-
Key Interlock - Up to four optional key interlocks are available tection at calculated arcing current is possible. For most industrial
(Kirk, Ronis, Profalux, Castell). Switchgear applications utilize a Kirk systems, the GE ArcWatch solution will result in incident energy
key interlock mounted in the cassette. A maximum of two key under 8 cal/cm2 at 18.
interlocks may fit in the cassette. Enabling ArcWatch means the proper coordination analysis
Mounting Straps/Accessories Kits - are available to mount and techniques have been used to determine the necessary circuit
connect fixed/stationary breakers. breaker protection features and settings that allow full coordina-
tion in the given system. The circuit breaker must be set to match
Optional Lockable Shutters - are available (factory installed).
the results of the completed study.
Carriage Position Switch - This optional cassette/substructure
For more information, check out www.geindustrial.com/ArcWatch
device permits local or remote indication of the circuit breaker
(Publication DET-760) or contact your local sales representative.
status (CONNECTED, TEST, DISCONNECTED), 2NO/2NC single pole,
double throw contacts are available for each position.
Lifting Truck - Optional lifting tool with separate slings is
available for all breaker sizes.
Optional IP Covers - IP54 covers (protected against harmful
amounts of dust and splashing water) are available for all
breaker sizes.
Mechanical Counter - Provides local record of the cumulative
number of complete breaker closing operations.
Cable Interlocks - (OEM Applications Only) Available for fixed and
draw-out breakers, these units enable direct interlocking of
EntelliGuard G circuit breakers.
Bell Alarm Contact - Available with or without a mechanical lock-
out feature, the bell alarm operates when the trip unit issues a
trip command.

Rev. 11/13 www.geindustrial.com BuyLog Catalog 8-3


Data subject to change
without notice
Low Voltage Power & Insulated Case Circuit Breakers Section 8

EntelliGuard G Low Voltage Power Circuit Breaker
EntelliGuard TU Trip Units

EntelliGuard TU Trip Units


EntelliGuard TU Trip Units enable the EntelliGuard G circuit
breaker with advanced technology and superior circuit protection
without compromising selectivity or arc flash protection.
EntelliGuard TU series trip units are available as the standard
controller for new production EntelliGuard G ANSI/UL 1066, UL
489 and IEC circuit breakers.
These cutting edge trip units provide Zone Selective
Instantaneous Protection, Waveform capture, Reduced Energy Let
Through Instantaneous Trip and are designed to supply commu-
nications for Modbus or Profibus protocols.
Note: See page 8-49 for more information about the
EntelliGuard TU Trip Unit.

Accessories
There are more than 20 different types of factory or field
installed accessories available for the EntelliGuard G circuit
breaker. Whether its a bell alarm contact, key interlock or
redundant shunt trips, GE has the accessory combinations to
meet your need!
Factory-Installed Accessories
Motor Operators
Closing Devices
Shunt Trip for Ground Fault
UVR with Fixed Time Delay
Second Shunt Trip or UV Release
Auxiliary Switches and Contacts
Bell Alarm and Trip Annunciation
Bell Alarm Contact
Trip Annunciation
Breaker Mounted Key Interlocks
Mechanical Interlocks- Fixed Breakers
Mechanical Interlocks Drawout Breakers
Accessories for Field Installation
Carriage Position Switch
Coil Signaling Contact Module
Contact Wear Indicator
Door Interlock
Electrical Close Switch
Lock Kits
Lifting Truck
Mechanical Operation Counter
Pushbutton Padlock Device
Ready-to-Close Switch
Secondary Disconnect Block
Spring Charged Contact
UVR Time Delay Module
Note: See page 8-15 for more information about the accessories
available for EntelliGuard G Circuit Breakers.

8-4 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Low Voltage Power & Insulated Case Circuit Breakers Section 8

EntelliGuard G Circuit Breaker
EntelliGuard G Circuit Breaker Nomenclature

EntelliGuard G Circuit Breaker Product Number Structure

G A 1 6 M 1 H E R X 5 R A X X L 4 X 6 V
Digit 1 2 3, 4 5 6 7 8 9 10 11 12 13 14 15 16, 17 18 19 20 Digit

Circuit
Breaker Family Rating Plug
G = EntelliGuard G 1900
Breaker/Switch
Advanced Features and
Breaker Switch Type Communications
A = ANSI/U 1066 Monitoring + Data acq.,
Circuit Breaker Modbus Protocol + RELT

Current Rating/Sensors Zone Selective Interlocking (ZSI)


16 = 1600A None

Short Circuit Withstand Rating Overcurrent Protection Ground Fault


Interrupting Rating Tier ANSI/UL 1066 LSIG

Mounting Mechanical Interlock


M = OEM, Drawout, 3 poles None DEFAULT

Spring Charge Motor Key Interlock & Padlock Provisions


1 = AC - 120Vac None

Closing Devices Bell Alarm, Mechanical Counter, Trip Annunciation


E = Closing Coil - 110Vdc/130Vdc; 120Vac Bell Alarm Contact with lockout

Shunt Trip Auxiliary Switch, Coil Signaling Contact


R = 110/125Vdc; 120Vac CSC, Hi-Fi Via Trip Unit - 2nd ST or 2nd UVR

Under Voltage Release (UVR) Second Shunt Trip, Second UVR


X = None R = Second Extended Range Shunt Trip 110/125Vdc; 120Vac

Digit 1 Circuit Breaker Family Digits 3 and 4 Current Rating / Sensor


Device Series Line Code Current Sensor Circuit Breaker Switches1
EntelliGuard G Breaker/Switch G Rating (A) ANSI UL489 ANSI UL489
400 04 04
600 06
Digit 2 Breaker Switch Type 800 08 08 08 08
Breaker/Switch Type, Envelope 1 Envelope 2 & 3 1000 10
Secondary Mounting Side Top Top 1200 12 12
1600 16 16 16 16
ANSI/UL1066 Circuit Breaker A N A
2000 20 20 20 20
UL 489 Circuit Breaker B U B
2500 25 25
ANSI Non-auto CB C M C 3000 30 30
(ANSI Switch)
3200 32 32
UL489 Non-auto CB D S D 4000 40 40 40 40
(UL Switch)
5000 50 50 50 50
Top = Top Mounted Secondary Disconnects (TSD). 6000 60 60
Side = Side Mounted Secondary Disconnects (SSD). (Available on Envelope 1 only.) 1Switches (Digit 2 = M, S, C, D) do not have current Sensors or a trip unit
NOTE: N, U, M, S characters are for Envelope 1 only with top mounted secondary
disconnects (TSD).
When ordering codes A, B, C, D, Side Secondary Disconnects (SSD) are supplied as
standard on Envelope 1.
Codes N, U, M, S are not valid for Envelopes 2 and 3.
Envelope 1 (Type N and H, 400A - 2000A).
NOTE: DC Ratings; trip unit not included. DC Rated Circuit Breakers require external
control devices (e.g., Type 37 or Type 76 DC Relays).
NOTE: Side Secondary Disconnects are specifically intended for 5-High ("high
density") equipment designs.
With Side Mounted Disconnects (SSD), the following Aux. Switches are not valid (In
Digit 12); Auxiliary Switch, 8NO+8NC (Power Rated) or Aux. Switch, 4NO/4NC
(Power Rated) + 4NO/4NC (High Fidelity).

Rev. 11/13 www.geindustrial.com BuyLog Catalog 8-5


Data subject to change
without notice
Low Voltage Power & Insulated Case Circuit Breakers Section 8

EntelliGuard G Circuit Breaker
EntelliGuard G Circuit Breaker Nomenclature

Digit 5 Short Circuit Withstand Ratings


Interrupting Rating Tier ANSI/UL1066 Devices, LVPCB Envelope 1 Envelope 2 Envelope 3
1/2S Override Override
Code 254V 580V 635V Withstand HSIOC No. 1 WI Code 400-1200 400-2000 3200 400-3200 3200 4000-5000
S 65,000 65,000 50,000 50,000 50,000 49,000 53,500 S X
N 65,000 65,000 65,000 65,000 None None None N X X
H 85,000 85,000 65,000 65,000 65,000 63,700 69,500 H X
P2 100,000 100,000 65,000 65,000 65,000 63,700 69,550 P X
E 85,000 85,000 85,000 85,000 None None None E X
M 100,000 100,000 100,000 85,000 85,000 83,800 90,950 M X X
B 100,000 100,000 100,000 100,000 None None None B X X
L 150,000 150,000 100,000 100,000 100,000 98,000 107,000 L X X

Interrupting Rating Tier UL489 Devices ICCB Envelope 1 Envelope 2 Envelope 3


1/2S Override Override
Code 240V 480V 600V Withstand HSIOC No. 1 WI Code 400-1200 400-2000 2500-3000 400-3000 3000 4000-6000
S 65,000 65,000 50,000 42,000 42,000 N/A 44,940 S X
N 65,000 65,000 65,000 42,000 42,000 N/A 44,940 N X X
H 85,000 85,000 65,000 50,000 50,000 N/A 53,500 H X X
P2 100,000 100,000 65,000 50,000 50,000 N/A 53,500 P X
M 100,000 100,000 100,000 65,000 65,000 N/A 69,550 M X X
L 150,000 150,000 100,000 85,000 85,000 N/A 90,950 L X X

Close and Latch Ratings (MCR set accordingly)


UL/ANSI 1 42,000
UL/ANSI 2 65,000 UL/ANSI CB MCR setting determined base on Envelope only. For Retrofill's (A = 17,000, B = 33,000, N = 42,000)
UL/ANSI 3 100,000
S N H M E L
IEC 1 42,000 42,000 42,000
IEC 2 50,000 50,000 65,000 65,000
IEC 3 100,000 100,000

Notes: Override has 7% pick up tolerance. Nominal setting is 98% of lcw if no other instantaneous is on, or 107% of lcw if any other instantaneous is on. UL 489 CB always
have other instantaneous protection on. MCR set at 78% Close and Latch rating with a -10% tolerance. 6000A UL 489 CB is 100% rated as stationary and 80% rated
draw-out.

ANSI Non-Automatic Switches 30 Cycle Withstand Ratings Envelope 1 Envelope 2 Envelope 3


Code 254V 580V 635V Code 800-2000 800-3200 3200-5000
N 42,000 42,000 42,000 N X
1.
M 65,000 65,000 65,000 M X
B 100,000 100,000 100,000 B X

UL489 Non-Automatic Switches 30 Cycle Withstand Ratings Envelope 1 Envelope 2 Envelope 3


Code 240V 480V 600V Code 800-2000 800-3000 3000-6000
N 42,000 42,000 42,000 N X
1.
M 65,000 65,000 65,000 M X
B 150,000 150,000 100,000 B X
1 Non-automatic switches are provided with no internal sensing or tripping mechanism and cannot be applied above their respective withstand levels. If non-automatic
device is required at ratings above the available switches required, it is recommended that a circuit breaker set with maximum setting be employed using external control
or protection as required by the application
2 P frame available as 3-pole only

Note: IEC Ratings are also available upon request.

UL489B Ratings Suitable for use in Photovoltaic system in accordance with article 690 of the NEC
Rated Endurance
Minimum Minimum
Minimum Electrical Electrical
Short Interrupting Mechanical Endurance at Endurance at
Envelope Type Amps Current (kA) Endurance 600Vdc 1000Vdc
2 M 800-3000 30 12500 500 500

Four configurations available for 600Vdc and 1000Vdc with or without isolating both DC legs.
Note: Bus Bars must be ordered separately
Time Constant (L/R) = 15msec, Rated calibration temperature 50C.

Note: See EntelliGuard G Circuit Breaker Configurator for pricing. Contact a sales representative for configurator.

8-6 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Low Voltage Power & Insulated Case Circuit Breakers Section 8

EntelliGuard G Circuit Breaker
EntelliGuard G Circuit Breaker Nomenclature

Digit 6 Mounting
Designation Mounting Poles Code
3 1
Drawout 4, right 2
4, left 3
OEM 3 4
Stationary 4, right 5
4, left 6
Drawout 3 D
GE Equipment
Stationary 3 F
NOTE: Right, Left indicates the location of the fourth pole, typically used to switch the Neutral.
NOTE: 800A Envelope 2 (E, M Ratings) are not available in 4-pole design.
NOTE: P frame available as 3-pole only

Digit 7 Spring Charge Motor Digit 9 Shunt Trip


Spring Charge Motor Electrically Operated (EO) Code Extended Range Shunt Trip (ANSI/UL)4 Code
24/30Vdc A
24Vdc M
48Vdc B
48Vac/dc P
DC 60Vdc C
70-72Vdc Q
72Vdc D
110/125Vdc; 120Vac R
110/130Vdc E
208Vac S
250Vdc F
220Vdc; 240Vac T
48Vac G
250Vdc; 277Vac V
120Vac H
AC Blank/none X
240Vac J
277Vac K 4TheExtended Range Shunt Trip is specifically intended and required for UL ANSI
Blank/None1 X Ground Fault applications. The pick up range is 55-110% of the ST coil voltage.
1An "X" (Blank/None) denotes a Manually Operated device (MO) When a motor is selected from the Spring Charging Motor (Digit 7) a Shunt Trip must
Spring Charge Contact, GSCC1, included with all Motor Operators. be selected.
NOTE: When a Spring Charging Motor is selected, a Closing Device must be selected
from Closing Devices for Digit 8, and a Shunt Trip Device must be selected from SELECT ONE DEVICE ONLY.
Shunt Trip 1 Devices for Digit 9.
Shunt Trip 1 with a coil voltage different from the Spring Charge Motor may be user- Digit 10 Under Voltage Release (UVR)
selected.
UVR with Fixed Time Delay5 Code
When a Motor & Spring Charge Contact is selected, the Ready To Close (RTC) (Digit
24Vdc 1
13) contact output options to the SD (Codes 1, 2, D, E, G, H, K, L) will be wired to
30Vdc 2
the Spring Charge Contact location on the Secondary Disconnect Block. 48Vac/dc 3
60-72Vdc 4
110/130Vdc; 120Vac 5
Digit 8 Closing Devices 208Vac 6
Closing Coil Type Code 220Vdc; 240Vac 7
24Vdc A 250Vdc; 277Vac 8
30Vdc B Blank/none X
48Vac/dc C 5TheUVR Shunt Trip with Fixed Time Delay is specifically intended for applications
60-72Vdc D
Closing Coil (CC)2 110Vdc/130Vdc; 120Vac E where a delay period ('ride-through') is required due to potential voltage events.
208Vac F The design delays are 50msec when system voltage drops to 50% and 20 msec
220Vdc; 240Vac G when system voltage drops below 50%.
250Vdc; 277Vac H
An optional External UVR Time Delay Module is available in a 1 - 3sec delay.
24Vdc M
30Vdc N SELECT ONE DEVICE ONLY.
48Vac/dc P
Command Operated 60-72 Vdc Q
Closing Coil (CCC)3 110Vdc/130Vdc; 120Vac R
208Vac S
220Vdc; 240Vac T
Blank/None X
2The Closing Coil (CC) permits either local or remote release of the spring charged
closing mechanism by electrical operation.
3The Command Operated Closing Coil (CCC) includes an additional anti-pumping

safety feature to ensure that the electrical closing signal must be released
before further closure is attempted, a shut off is initiated if the closing signal is
maintained.
NOTE: Manual button through breaker cover is included as standard assembly.
NOTE: When a Spring Charging Motor is selected (Digit 7), a Closing Device must be
selected from Closing Devices for Digit 8, and a Shunt Trip Device must be
selected from Shunt Trip 1 Devices for Digit 9.
SELECT ONE DEVICE ONLY.

Rev. 11/13 www.geindustrial.com BuyLog Catalog 8-7


Data subject to change
without notice
Low Voltage Power & Insulated Case Circuit Breakers Section 8

EntelliGuard G Circuit Breaker
EntelliGuard G Circuit Breaker Nomenclature

Digit 11 Second Shunt Trip, Second UVR


Type Code
24Vdc 1
30Vdc 2
48Vac/dc 3
Second UVR with Fixed 60-72Vdc 4
Time Delay1 110Vdc/130Vdc; 120Vac 5
208Vac 6
220Vdc; 240Vac 7
250Vdc; 277Vac 8
24Vdc M
48Vac/dc P
Second Extended 70-72Vdc Q
Range Shunt Trip 110/125Vdc; 120Vac R
(ANSI/UL)2 208Vac S
220Vdc; 240Vac T
250Vdc; 277Vac V
Blank/none X
1The UVR with Fixed Time Delay is specifically intended for applications where a delay period ('ride- through') is required due to potential voltage events. The design delays
are 50msec when system voltage drops to 50% and 20msec when system voltage drops below 50%.
2The Extended Range Shunt Trip is specifically intended and required for UL ANSI Ground Fault applications. The pickup range is 55-110% of the ST coil voltage.

An optional External UVR Time Delay Module is available in a 1 - 3 second delay.


SELECT ONE DEVICE ONLY.

Digit 12 Auxiliary Switch, Coil Signaling Contact


Contact Configuration Code
Auxiliary Switch, 3NO+3NC (Power Rated)3 STANDARD/INCLUDED 2
Auxiliary Switch, 8NO+8NC (Power Rated)4 4
Aux. Switch, 3NO/3NC (Power Rated) +2NO/2NC (High Fidelity) 6
Aux. Switch, 4NO/4NC (Power Rated) +4NO/4NC (High Fidelity)4 8
CSC, PR, (1NO on SD) - Close Coil or CCC A
CSC, Hi-Fi via Trip Unit - Close Coil or CCC5 B
CSC, PR, (1NO on SD) - 1st Shunt Trip C
Auxiliary Switch, 3NO+3NC CSC,Hi-Fi via Trip Unit - 1st Shunt Trip5 D
(Power Rated) CSC, PR, (1 NO on SD) - 1st UVR E
CSC,Hi-Fi via Trip Unit - 1st UVR5 F
CSC, PR, (1NO on SD) - 2nd ST or 2nd UVR G
CSC, Hi-FI via Trip Unit - 2nd ST or 2nd UVR5 H
CSC, PR, (1NO on SD) - Close Coil or CCC J
CSC, Hi-Fi via Trip Unit - Close Coil or CCC5 K
CSC, PR, (1NO on SD) - 1st Shunt Trip L
CSC,Hi-Fi via Trip Unit - 1st Shunt Trip5 M
Auxiliary Switch, 3NO/3NC (Power Rated)+2NO/2NC (High Fidelity)
CSC, PR, (1 NO on SD) - 1st UVR N
CSC,Hi-Fi via Trip Unit - 1st UVR5 P
CSC, PR, (1NO on SD) - 2nd ST or 2nd UVR Q
CSC, Hi-FI via Trip Unit - 2nd ST or 2nd UVR5 R
CSC, PR, (1NO on SD) - All Installed Devices S
Auxiliary Switch, 3NO+3NC (Power Rated)
CSC,HI-Fi via Trip Unit - All Installed Devices5 T
CSC, PR, (1NO on SD) - All Installed Devices U
Aux. Switch, 3NO/3NC (Power Rated) + 2NO/2N (High Fidelity)
CSC,HI-Fi via Trip Unit - All Installed Devices5 V

Abbreviations
CCC = Command Operated Close Coil
CSC = Coil Signaling Contact
Hi-Fi = High Fidelity
PR = Power Rated
SD = Secondary Disconnect

NOTE: The term "Hi Fidelity" (HiFi) refers to gold-plated contacts used for signal level outputs (10mA minimum - 100mA maximum, 5-30Vdc, 125Vac)
NOTE: If no devices were selected in Digit 8, 9, 10, 11 (Codes = "X"), then Options A - V are Invalid
NOTE: Options A-V are only valid if the corresponding device to be monitored by the Coil Signaling Contact (CSC) is selected in digits 8, 9, 10, 11
3The 3NO/3NC scheme is STANDARD (INCLUDED, CODE 2) and is wired to Secondary Disconnect Block A; all other selections require Secondary Disconnect Block B
4For Side-mounted Secondary Disconnect Blocks All options are available EXCEPT options (4 and 8)
5In order to output the Coil Signaling status HiFi via trip unit (Options B, D, F, H, K, M, P, R, T, and V) a communications package must be selected in Advanced Features (Digit

19; options "2, 3, 6, 7, 8, 9") This options requires Secondary Disconnect Block B.
If a UL or ANSI Switch is selected in Digit 2 (C, D, M, S), the HiFi via Trip unit Options are not valid (Options B, D, F, H, K, M, P, R, T, and V)

Note: See EntelliGuard G Circuit Breaker Configurator for pricing. Contact a sales representative for configurator.

8-8 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Low Voltage Power & Insulated Case Circuit Breakers Section 8

EntelliGuard G Circuit Breaker
EntelliGuard G Circuit Breaker Nomenclature

Digit 13 Bell Alarm, Mechanical Counter and Trip Annunciation Digit 15 Mechanical Interlocks
Bell Alarm, Mechanical Counter and Trip Annunciation Code Mechanical Interlocks Code
Bell Alarm Contact (1NO/1NC) with Lockout(BACL) A Black/None DEFAULT X
Mechanical Operations Counter(MOC) B Mechanical Interlock- Type A 1
Bell Alarm Contact (1NO/1NC) with Lockout and MOC C Mechanical Interlock- Type B 2
RTC Power Rated Contacts on SD1 1 Mechanical Interlock- Type C 3
RTC Signal Rated (HI-Fi) Contacts on SD1 2 Mechanical Interlock- Type D 4
RTC Signal Rated(HI-Fi) Contacts on SD1 3
RTC Signal Rated (HI-fi) Conatcts through Trip Unit2 D
Some installations use multiple power sources that are required to supply energy
BACL and RTC Power Rated Contacts on SD1 E simultaneously, alternately, or, in a specified sequence. EntelliGuard G Circuit
BACL and RTC Signal Rated (Hi-Fi) Contacts on SD1 F Breakers can be used to interconnect these sources and be electrically and
BACL and RTC Signal Rated (Hi-Fi) through Trip Unit 2 G mechanically interlocked to provide the necessary transition and protection.
BACL,MOC and RTC Power Rated on SD1 H Mechanical Interlocks are available for fixed and draw out circuit breakers.
BACL,MOC and RTC Signal Rated (Hi-Fi) through Trip Unit2 J The interlocks enable directly interlocking breakers that are mounted side by side
MOC and RTC Power Rated on SD1 K or in vertical stacks. The interlocks consist of two components: (1) The factory-
MOC and RTS Signal Rated on SD1 L
installed bracket fitted to the breaker (fixed breakers) or the cassette (drawout
MOC and RTC Signal Rated (Hi-Fi) through Trip Unit2 M
Blank/none X
breakers), and (2) The field-installable interconnecting cables available in lengths
of 1.0, 1.6, 2.0, 2.5, 3.0, 3.5 and 4.0m (ordered separately). Refer to Section 4 of the
Abbreviations Application Guide DET-653B for interlocking schemes.
BACL = Bell Alarm Contact with Lockout
RTC = Ready To Close Contacts Contact factory for availability.
Hi-Fi = High Fidelity
SD = Secondary Disconnect
1Ready To Close Switches are wired to where a Spring Charge Contact would be
2In order to output the RTC contact output via Trip Unit (options 3, F, J, M) a
communications package must be selected in Advanced Features
(Code 19/Step 16); this requires Secondary Disconnect Block B.
If a UL or ANSI Switch is selected, the (Hi-Fi Through Trip Unit) is not valid
(Options 3, F, J, M).
RTC Through the Trip Unit is not a valid option for Switches. Bell Alarm
Contact with Lockout comes with the Trip Unit set to Manual LO Enabled.
NOTE: The term Hi-Fi refers to gold-plated contacts used for signal level
outputs (10mA minimum - 100mA maximum, 5-30Vdc, 125Vac).
Bell Alarm Contact with Lockout comes with the Trip unit set to Manual LO Enabled

Digit 14 Key Interlock and Padlock Provisions


Key Interlock (Breaker Mounted) Code
Castell Key Interlock C
Kirk Key Interlock K
Ronis Key Interlock R
Pushbutton Padlock Device L
Castell Key Interlock and Push Button Padlock Device 1
Kirk Key Interlock and Push Button Padlock Device 2
Ronis Key Interlock and Push Button Padlock Device 3
Black/none X

NOTE: This option provides factory installed interlocking devices for installation
between separate circuit breakers (baseplates and mechanism). This safeguard
ensures that a circuit breaker cannot be closed unless the dedicated key has been
inserted and secured within the lock.
NOTE: If selecting a Draw Out Breaker (Digit 6), consider putting the Key Interlock on
the Cassette versus the breaker. This enables the ability to swap breakers without
having to change the key interlocks.
Locks and Keys are NOT Supplied by GE.

Note: See EntelliGuard G Circuit Breaker Configurator for pricing. Contact a sales representative for configurator.

Rev. 11/13 www.geindustrial.com BuyLog Catalog 8-9


Data subject to change
without notice
Low Voltage Power & Insulated Case Circuit Breakers Section 8

EntelliGuard G Circuit Breaker
EntelliGuard G Circuit Breaker Nomenclature

Digit 16 and 17 Over Current Protection Package


Type Over Current (OC) Protection Ground Fault Code
LSI (S, switchable) (I, switchable ANSI only) L3
LSIG (S, switchable) (I, switchable ANSI only) L4
LSIGA (S, switchable) (I, switchable ANSI only) (G, Alarm Only) L5
Standard Range
LSIC (S, switchable) (I, switchable ANSI only) L6
Instantaneous
LSICA (S, switchable) (I, switchable ANSI only) (C, Alarm Only) L7
EntelliGuard G LSIGDA1 (S, G, A switchable) (I, switchable ANSI only) L8
ANSI/UL OC LSIGCDA1 (S, G, C, A all switchable) (I, switchable ANSI only) L9
Protection LSH (S, switchable) (I, switchable ANSI only) LC
LSHG (S, switchable) (I, switchable ANSI only) LD
Extended Range LSHGA (S, switchable) (I, switchable ANSI only) (G, Alarm Only) LE
Adjustable LSHC (S, switchable) (I, switchable ANSI only) LF
Instantaneous LSHCA (S, switchable) (I, switchable ANSI only) (C, Alarm Only) LG
LSHGDA1 (S, G, A switchable) (I, switchable ANSI only) LH
LSHGCDA1 (S, G, C, A all switchable) (I, switchable ANSI only) LK
NONE - (For Switch Only) XX
1Function Combination is NOT UL Listed
NOTES:
L = Long Time (L, I2T) + Fuse Settings (I4T) (Fuse settings are now standard on all EntelliGuard Trip Units)
S = Short Time (Switchable if Instantaneous (I) protection is enabled)
I = Standard Range Adjustable Instantaneous, (IOC, 2x-15x)
H = Extended Range Adjustable Instantaneous, (IOC, 2x-30x), Not available in UL489 version of Entelliguard G or any Legacy CB
G = Ground Fault Protection (GFP, 3-wire or 4-wire, internal summing)
C = External CT for ground fault detection (AKD20 application: input from external summing CTs, used for multiple source ground fault detection.
OEM Application: Zero Sequence Input of (1A = 100%)
D = Defeatable/Switchable Ground Fault NOT UL Listed
A = Ground Fault, External Ground Fault, Alarm only
GA = Ground Fault Alarm Only
CA = External Ground Fault Alarm Only
GDA, GCDA = Ground Fault Trip and Ground Fault Alarm (all switchable, Not UL Listed)
Option "XX" is the only valid option when a Switch is selected in Digit 2

Digit 18 Zone Selective Interlocking (ZSI) Digit 20 Rating Plug


Zone Selective Interlocking Code Rating Plug Product Number Code
ZSI, Short time and GF; user selectable Z 150 GTP0150U0104 B
Z+IOC or HSIOC ZSI; user selectable T 200 GTP0200U0204 C
Blank/none X 225 GTP0225U0306 D
250 GTP0250U0407 E
ZSI selections require Secondary Disconnect Block B and 24Vdc control power.
300 GTP0300U0408 F
NOTE: Option X is the only valid item when a Switch is selected in Digit 2. 350 GTP0350U0408 G
400 GTP0400U0410 H
Digit 19 Advanced Features and Communications 450 GTP0450U0612 I
Advanced Features and Communications Code 500 GTP0500U0613 J
600 GTP0600U0616 K
Reduced Energy Let Through (RELT) 1 700 GTP0700U0816 M
Modbus Protocol + RELT 2 750 GTP0750U0820 N
Profibus Protocol + RELT 3 800 GTP0800U0820 O
Monitoring + RELT, NO communication 4 900 GTP0900U1020 P
Monitoring + Relay Package + RELT 5 1000 GTP1000U1025 Q
Monitoring+ Data Acquisition, Profibus Protocol + RELT 6 1100 GTP1100U1225 R
Monitoring+ Data Acquisition, Modbus Protocol + RELT 7 1200 GTP1200U1232 S
Monitoring + Data Acquisition, Relay Package, Profibus, RELT 8 1500 GTP1500U1640 U
Monitoring + Data Acquisition, Relay Package, Modbus RELT 9 1600 GTP1600U1640 V
None X 1900 GTP1900U2050 W
2000 GTP2000U2050 Y
NOTES:
2200 GTP2200U2550 Z
All Advanced Feature selections require Secondary Disconnect Block B and 24Vdc
2400 GTP2400U2564 1
control Power. 2500 GTP2500U2564 2
Option "X" is the only valid option when a Switch is selected in Digit 2. 3000 GTP3000U3064 3
RELT = Reduced Energy Let Through, requires dedicated input and output on the 3200 GTP3200U3264 4
CB Monitoring = Advanced Metering. 3600 GTP3600U4064 5
Data Acquisition = Waveform Capture and Harmonic Analysis. 4000 GTP4000U4064 6
In order to output the Coil Signaling status HiFi via trip unit (Digit 12, Options B, D, 5000 GTP5000U5064 7
6000 GTP6000U6064 8
F, H, K, M, P, R, T, and V) a communications package must be selected in Advanced
Rating plug not required/non auto switch X
Features (Digit 19; options 2, 3, 6, 7, 8, 9). This option requires Secondary
Disconnect Block B. NOTE: See Section 6 for further details on rating plugs and sensors. Option X is the
In order to output the RTC contact output via Trip Unit (Digit 13; Options 3, F, J, M) a only valid option when a Switch is selected in Digit 2.
communications package must be selected in Advanced Features (Code 19/Step
16); this requires Secondary Disconnect Block B.

Note: See EntelliGuard G Circuit Breaker Configurator for pricing. Contact a sales representative for configurator.

8-10 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Low Voltage Power & Insulated Case Circuit Breakers Section 8

EntelliGuard G Low Voltage Power Circuit Breakers
EntelliGuard G Cassettes Nomenclature

The drawout mechanism allows the breaker to be racked in four distinct positions (CONNECTED, TEST, DISCONNECTED, WITHDRAWN).
Choice of whether shutters are needed are based in the order option 2nd disconnect Block B (GSDWCR).

EntelliGuard G Cassette Product Number Structure

G A 16 M 2 5
Digit 1 Digit 2 Digit 3,4 Digit 5 Digit 6 Digit 7

Circuit Breaker Cassette Family Shutters


G=EntelliGuard G Shutter and Shutter Lock-
Breaker/Switch Factory Installed

Breaker Switch Type Number of Poles


ANSI / UL1066 Circuit Breaker OEM Cassette - 3 Pole

Current Rating Cassette AIC Rating


1600 A Envelope 2, 400-3200 Envelope 3, 4000-5000

Digit 1 Circuit Breaker Cassette Family Digit 3 and 4 Current Rating


Devices Series/Line Code Circuit Breaker
Current Rating (A)
ANSI UL489
EntelliGuard G Breaker/Switch G
800 08 08
1600 16 16
2000 20 20
Digit 2 Breaker Switch Type 3000 - 30
Cassette Type, Envelope 1 Envelope 2 & 3 3200 32 -
Secondary Mounting Side Top Top 5000 50 -
ANSI/UL1066 6000 - 60
A N A
Circuit Breaker
NOTE: Select Current Rating equal to or the next higher of the Circuit Breaker or
UL489 Circuit Breaker B U B
Switch Current Rating
ANSI Non-auto CB C M C
(ANSI Switch)
UL489 Non-auto CB D S D
(UL Switch)

Top = Top Mounted Secondary Disconnects (TSD).


Side = Side Mounted Secondary Disconnects (SSD). (Available on Envelope 1 only).
N, U, M, S characters are for Envelope 1 only with top mounted secondary
disconnects (TSD).
When ordering codes A and B, Side Secondary Disconnects (SSD) are supplied as
standard on Envelope 1.
Codes N and U, are not valid for Envelopes 2 and 3.
Envelope 1 (Type N and H, Circuit Breaker and Switches, 800A - 2000A).
NOTE: Side Secondary Disconnects are specifically intended for 5-High
("high density") equipment designs
With Side Mounted Disconnects (SSD), EntelliGuard Circuit Breakers Auxiliary
Switches cannot be 8NO+8NC (Power Rated) or Aux. Switch, 4NO/4NC (Power
Rated) + 4NO/4NC (High Fidelity)

Rev. 11/13 www.geindustrial.com BuyLog Catalog 8-11


Data subject to change
without notice
Low Voltage Power & Insulated Case Circuit Breakers Section 8

EntelliGuard G Low Voltage Power Circuit Breakers
EntelliGuard G Cassettes Nomenclature

Digit 5Cassette AIC Rating


Interrupting Rating Tier ANSI/UL1066 Devices, LVPCB Envelope 1 Envelope 2 Envelope 3
1/2S Override
Code 254V 580V 635V Withstand HSIOC No. 1 Override WI Code 400-1200 400-2000 3200 400-3200 3200 4000-5000

S 65,000 65,000 50,000 50,000 50,000 49,000 53,500 S X


N 65,000 65,000 65,000 65,000 None None None N X X
H 85,000 85,000 65,000 65,000 65,000 63,700 69,500 H X
P2 100,000 100,000 65,000 65,000 65,000 63,700 69,500 P X
E 85,000 85,000 85,000 85,000 None None None E X
M 100,000 100,000 100,000 85,000 85,000 83,800 90,950 M X X
B 100,000 100,000 100,000 100,000 None None None B X X
L 150,000 150,000 100,000 100,000 100,000 98,000 107,000 L X X

Interrupting Rating Tier UL489 Devices ICCB Envelope 1 Envelope 2 Envelope 3


1/2S Override
Code 240V 480V 600V Withstand HSIOC No. 1 Override WI Code 400-1200 400-2000 2500-3000 400-3000 3000 4000-6000

S 65,000 65,000 50,000 42,000 42,000 N/A 44,940 S X


N 65,000 65,000 65,000 42,000 42,000 N/A 44,940 N X X
H 85,000 85,000 65,000 50,000 50,000 N/A 53,500 H X X
M 100,000 100,000 100,000 65,000 65,000 N/A 69,550 M X X
L 150,000 150,000 100,000 85,000 85,000 N/A 90,950 L X X
P2 100,000 100,000 65,000 50,000 50,000 N/A 50,000 P X

ANSI Non-Automatic Switches 30 Cycle Withstand Ratings Envelope 1 Envelope 2 Envelope 3


Code 254V 580V 635V Code 800-2000 800-3000 3000-6000

N 42,000 42,000 42,000 Note: Non-automatic switches are provided N X


M 65,000 65,000 65,000 with no internal sensing or tripping mechanism M X
B 100,000 100,000 100,000 and cannot be applied above their respective B X
withstand levels. If a non-automatic device is
UL489 Non-Automatic Switches required at ratings above the available switches Envelope 1 Envelope 2 Envelope 3
Code 240V 480V 600V is required, it is recommended that a circuit Code 800-2000 800-3000 3000-6000
breaker set with maximum setting be employed
N 42,000 42,000 42,000 using external control or protection as required N X
M 65,000 65,000 65,000 by the application. M X
B 150,000 150,000 100,000 B X

Digit 6 Number of Poles


Devices Series/ Line Code
OEM Cassette - 3 Pole 2
OEM Cassette - 4 Pole 5
GE Equipment Cassette - 3 Pole1 7
1GE Equipment cassette designed specifically for AKD20 Switchgear.
These cassettes are NOT available for OEMs.
2P frame available as 3-pole only

Digit 7 Shutters
Shutters with Locks Code
Shutter and Shutter Lock - Factory Installed S
None X

Loose Cassette Parts- Field Installed Product Number


Carriage Position Switch - 1NO/1NC GCPS1R
Carriage Position Switch-2NO/2NC GCPS2R
1 Kirk Key Interlock Cam for Cassette GCKRKR
1 Ronis Key Interlock Cam for Cassette GCR0NR
Secondary Disconnect Block B, 39 Pole-Top Mounted GSDWTR
Secondary Disconnect Block B, 39 Pole-Side Mounted GSDWSR

Secondary Disconnect Block B is required when:


1. Any "ZONE SELECTIVE INTERLOCKING" options are selected in breaker/trip unit
Catalog Digit 18.
2. Any "ADVANCED FEATURES" are selected in breaker/trip unit Catalog Digit 19.
3. A COIL SIGNALING CONTACT OPTION is selected, Digit 12.
4. A READY TO CLOSE signal via the trip unit is selected, Digit 13.
5. Any of the following OPTIONAL Aux. Contact Switches are selected in Digit 12:
8NO/NC POWER RATED
3NO/NC POWER RATED + 2NO/NC Hi-Fi
4NO/NC POWER RATED + 4NO/NC Hi-Fi

8-12 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Low Voltage Power & Insulated Case Circuit Breakers Section 8

EntelliGuard G Low Voltage Power Circuit Breakers
EntelliGuard G Accessories

A wide range of optional accessories are interchangeable across


all EntelliGuard G power circuit breakers, regardless of nominal
rating or envelope/frame size.

Motorized Spring Charging Unit


The unique motor/gearbox unit is specially designed to operate
with the full range of EntelliGuard G breakers. It is easily installed
with three heavy-duty bolts. After a breaker close operation, the
unit automatically recharges the spring and makes it ready for
immediate re-close should the need arise. High speed recharging
ensures that the springs are fully charged within approximately
three seconds following a release. All electrically operated (EO) Motorized Spring Charging Unit
ANSI/UL breakers are equipped with Spring Charged
contacts for status indication.

Motorized Spring Charging Unit


Power Nominal UL and IEC Range
Envelope Consumption Control Voltage (85% to 110%) ANSI Range Product Number
24Vdc/30Vdc 20.4V to 26.4V - GM01024DR
48Vdc 40.8V to 52.87V 38V to 56V GM01048DR
60Vdc 51V to 66V - GM01060DR
1 DC - 300W
72Vdc 61.2V to 79.2V - GM01072DR
110Vdc/130Vdc 106.25V to 137.5V 100V to 140V GM01110DR
250Vdc 212.5V to 275V 200V to 280V GM01250DR
48Vac 40.8V to 52.87V - GM01048AR
120Vac 102V to 132V 104V to 127V GM01120AR
1 AC - 350VA
240Vac 204V to 264V 208V to 254V GM01240AR
277Vac 235.5V to 304.7V - GM01277AR
24Vdc/30Vdc 20.4V to 26.4V - GM02024DR
48Vdc 40.8V to 52.87V 38V to 56V GM02048DR
60Vdc 51V to 66V - GM02060DR
2 and 3 DC - 480W
72Vdc 61.2V to 79.2V - GM02060DR
110Vdc/130Vdc 106.25V to 137.5V 100V to 140V GM02110DR
250Vdc 212.5V to 275V 200V to 280V GM02250DR
48Vac 40.8V to 52.87V - GM02048AR
120Vac 102V to 132V 104V to 127V GM02120AR
2 and 3 AC - 560VA
240Vac 204V to 264V 208V to 254V GM02240AR
277Vac 235.5V to 304.7V - GM02277AR

Rev. 11/13 www.geindustrial.com BuyLog Catalog 8-13


Data subject to change
without notice
Low Voltage Power & Insulated Case Circuit Breakers Section 8

EntelliGuard G Low Voltage Power Circuit Breakers
EntelliGuard G Accessories

Circuit Breaker Closing Coils - Standard and Command


Two, easy-to-fit, clip-on closing coil options with simple,
plug-in connections are available. Both options offer
electrical remote release of the spring charged closing
mechanism. Both options include a standard anti-pump
safety feature ensuring that the close signal must be
released before further close commands are allowed. The
Command Close Coil additionally provides for local breaker
close and remote breaker close over communications via
the EntelliGuard Trip Unit.

Command Operation Module


This module energizes the closing coil to cause the breaker
to close whenever control power is applied to the accessory
and when commanded from the breaker trip unit or breaker
front panel push button (electrical closing.)
Close Coil

Closing Coil / Command Operation Module


Power Nominal
Type Consumption Control Voltage Product Number
DC: 350W, 24Vdc GCCN024DR
20 W (sealed) 48Vac/dc GCCN048R
60 to 72Vdc GCCN060DR
Closing Coil (CC) AC: 350W 110/130/120Vac GCCN120R
(inrush), 208Vac GCCN208AR
20W (sealed) 220Vdc/240Vac GCCN240R
250Vdc/277Vac GCCN277R
DC: 350W, 24Vdc GCCC024DR
20W (sealed) 48Vac/dc GCCC048R
Command Closing Coil (CCC) 60 to 72Vdc GCCC060DR
AC: 350W (inrush), 110/130/120Vac GCCC120R
20W (sealed) 208Vac GCCC208AR

Shunt Trip for Ground Fault


Energizing the shunt trip (ST), via local or remote input, will
instantaneously activate the circuit breaker mechanism, ensuring
a rapid open operation. The shunt trip is continuously rated
and does not require an auxiliary switch in series with the coil.
The shunt trip is a straightforward, field installable accessory
available in wide range of voltages.

Norminal Control Voltage Product Number


24Vdc GSTG024DR
48Vac/dc GSTG048R
70/72Vac GSTG072DR
125Vdc GSTG125DR
110Vdc/120Vac GSTG120R
208Vac GSTG208AR
240Vac GSTG240R
250Vdc/277Vac GSTG250DR

Shunt Trip

8-14 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Low Voltage Power & Insulated Case Circuit Breakers Section 8

EntelliGuard G Low Voltage Power Circuit Breakers
EntelliGuard G Accessories

Status Indication Switch (Coil Signaling Contact)


A plug-in module is available to provide status indication via the
secondary disconnects and trip unit. Coil Signaling Contacts are
available for closing coils, shunt trips and under voltage releases.
Contact is mounted on top of the Accessory Device. One of the
low signal (Hi-Fi) contacts is always wired to the trip unit.
Type and Product Status Indication Switch
Configuration Rating Voltage Amps Number
AC 120Vac 6
1 Power rated + AC 250Vac 6
1 Low signal (Hi-Fi) DC 120Vac 0.5 GCSP1R
(1NO contact each) DC 250Vac 0.25
AC 125Vac 0.1
DC 30Vdc 0.1
2 Low signal (Hi-Fi)
AC 125Vac 0.1 GCSP2R
(1NO contact each)

Status Indication Switch

Under Voltage Release (UVR) with Fixed Time Delay


The UVR instantaneously activates the circuit breaker trip
mechanism when the source voltage drops below the low voltage
threshold. The UVR is also a simple, field installable device.

Power Nominal
Consumption Control Voltage Product Number
24Vdc GUVT024DR
DC: 350W, 30Vdc GUVT030DR
2W (sealed) 40Vdc; 48Vac/dc GUVT048R
60 - 72Vdc GUVT060DR
110Vdc/130Vdc; 120Vac GUVT120R
AC: 350W
208Vac GUVT208AR
(inrush),
220Vdc; 240Vac GUVT240R Under Voltage Release
20W (sealed)
250Vdc; 277Vac GUVT277R

Duty Cycle = 2/min.


Inrush = 350VA (AC), 350W (DC)
Holding = 60VA (AC), 50W (DC)

Rev. 11/13 www.geindustrial.com BuyLog Catalog 8-15


Data subject to change
without notice
Low Voltage Power & Insulated Case Circuit Breakers Section 8

EntelliGuard G Low Voltage Power Circuit Breakers
EntelliGuard G Accessories

Time Delay Module (TDM) for UVR (Externally Mounted)


The de-energized operation of the Undervoltage release can be
delayed. This optional, externally mounted module has an
adjustable time delay of 0 seconds to 3 seconds. The device can
be implemented to prevent undesired breaker tripping due to
momentary voltage interruptions and is connected in series with
the Undervoltage release. The time delay is in addition to the time
delay from the breaker mounted UVR accessory. The time delay
module starts counting at 50% of rated voltage.

Nominal Control Voltage Product Number


48Vdc GTDM048D
48Vac GTDM048A
60Vdc GTDM060D
125Vdc GTDM120D
120Vac GTDM120A Time Delay Module
208Vac GTDM208A
240Vdc GTDM240D
240Vac GTDM240A
250Vdc GTDM250D
277Vac GTDM277A

Ready To Close Contact


These contacts indicate that the following conditions are met and
the circuit breaker can be closed:
The circuit breaker is open.
The closing springs are charged.
The circuit breaker is not locked/interlocked in open position.
There is no standing closing signal. Ready To Close Contact
There is no standing opening signal.

1 NO
Voltage Amps Description Product Number
120Vac 6 High fidelity/secondary disconnect
AC GRTC2R
250Vac 6
125Vdc 0.5 Power rated/secondary disconnect GRTC1R
DC
250Vdc 0.25 High fidelity/trip unit GRTC3R

Auxiliary Switches
Auxiliary switches indicate breaker main contact position. They
change their state in the same time sequence as the breaker
main contacts.

Contact Power Product


Configuration Rated Hi-Fi Number
Power rated (3NO, 3NC) A14 - A25 N/A GAUX3R
Power rated (3NO, 3NC); low signal (Hi-Fi), (2NO, 2NC) A14 - A25 B10 - B13, B23 - B26 GAUX5R
Power rated (8NO, 8NC) A14 - A25, B4 - B13, B17 - B26 N/A GAUX6R
Power rated (4NO, 4NC); low signal (Hi-Fi), (4NO, 4NC) A14 - A25, B12 - B13, B25 - B26 B4 - B11, B17 - B24 GAUX8R

8-16 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Low Voltage Power & Insulated Case Circuit Breakers Section 8

EntelliGuard G Low Voltage Power Circuit Breakers
EntelliGuard G Accessories

Circuit Breaker - Key Interlock Facility


This option supplies factory-installed key interlock mounting
provisions (baseplates and mechanism) on the front of the
breaker fascia. Key interlocks ensure that a circuit breaker cannot
be closed unless the dedicated key has been inserted and
secured within the lock. Circuit breakers accept ready-to-fit
interlocking device kits such as Castell, Ronis, Kirk and Profalux
for installation between related, separate circuit breakers.

Product
Description Number
Baseplate and mechanism for Kirk Key Key Interlock Facility
GBKRKR
Locks (Breaker Mounted)
Baseplate and mechanism for Ronis Locks GBRONR
(Breaker Mounted)
Mechanism for Ronis Key cassette interlock GCRONR
(Cassette mounted)
Mechanism for Kirk Key cassette interlock GCKRKR
(Cassette mounted)

Carriage Position Switch (TOC)


Available as an option for mounting within the base of the
cassette/substructure, the carriage position switch provides six
single-pole changeover contacts (single pole, double throw) for
local or remote electrical indication of the circuit breaker status:
CONNECTED, TEST and DISCONNECTED. The DISCONNECTED
position is indicated only when minimum isolating distances Carriage Position Switch
between contacts on both the main and auxiliary circuits have (TOC)
been achieved. This option is in addition to the mechanical
indicators, which are fitted as standard. When installed, the
carriage switch is IP2X protected.

Switch Product
Configuration Number
1 NO/NC switch per position GCPS1R
Set of 2 NO/NC switches per position GCPS2R
Set of 6 NO/NC switches connected position GCPS3R

Rev. 11/13 www.geindustrial.com BuyLog Catalog 8-17


Data subject to change
without notice
Low Voltage Power & Insulated Case Circuit Breakers Section 8

EntelliGuard G Low Voltage Power Circuit Breakers
EntelliGuard G Accessories

Mechanical Interlocks (Cable/Rod) (OEM Applications Only)


Available for fixed and draw-out circuit breakers, these units
enable the direct interlocking of EntelliGuard G circuit breakers,
either mounted side-by-side or stacked. The interlocking
mechanisms are connected by a specially designed cable or rod
in a 1 from 2, 1 from 3, and 2 from 3 configuration, and any mix
of current ratings/pole configurations can be accommodated.

Number of Product
Interlock Type Cables Required Breaker Type Poles Number
Withdrawable 3 GI2WADR
Withdrawable 4 GI3WADR
2 Way - Type A 2
Fixed 3 GI2FADR
Fixed 4 GI3FADR
Withdrawable 3 GI2WBR
Withdrawable 4 GI3WBR
1 from 2 - Type B 6
Fixed 3 GI2FBR
Fixed 4 GI3FBR
Withdrawable 3 GI2WCR
Withdrawable 4 GI3WCR
2 from 3 - Type C 6
Fixed 3 GI2FCR
Fixed 4 GI3FCR
Withdrawable 3 GI2WDTR
1 from 3 - Type D 4 Withdrawable 4 GI3WDTR
Fixed 3 GI2FDTR
Refer to Section 4 of the Application Guide DET-653B for interlocking schemes.

Mechanical Interlock Cables


Standard cable lengths are shown. (Cables ordered separately.
Please contact our technical customer service department if
longer length is required.)
Product
Length (M/In) Number
1 / 39.4 GCB1
1.6 / 63 GCB2
2 / 78.7 GCB3
2.5 / 98.4 GCB4
3 / 118/1 GCB5
3.5 / 137.8 GCB6
4 / 157.5 GCB7

Bell Alarm with Lockout


The Bell Alarm provides remote indication that the circuit breaker
has opened because of an electrical fault. The Lockout feature is
integral to the trip unit. When a Bell Alarm is supplied with the
breaker, the Trip Unit dial is set and locked to the manual position.
In order to re-close the breaker, the Lockout button must be
pushed in/reset on the Trip Unit 1-Form C contact. Bell Alarm with Lockout
Product
Switch Configuration Number
Single pole, double throw (1-Form C contact) GBAT1R

8-18 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Low Voltage Power & Insulated Case Circuit Breakers Section 8

EntelliGuard G Low Voltage Power Circuit Breakers
EntelliGuard G Accessories

Charging Spring Status Indicator


Factory-installed on the motor, this auxiliary switch indicates
that the circuit breaker is charged and is standard with the
spring-charging motor.
Ratings
Voltage Amps Product Number
120Vac 6
250Vac 6 GSCC1R
125Vdc 0.5
250Vdc 0.25

Charging Spring Status


Indicator
Neutral Rogowski
The Neutral Rogoswki CTs are used to measure the Neutral Arrow to face
ACB connection
Current and is required when Internal Ground Fault is selected on
the trip unit. There are two types available: Encased with Terminal
Screws: The Rogowski coil is encased with two terminal screws.
No additional mounting hardware is required as the encasing is
molded to the mounting dimensions. Fix coil to clamp
with cable ties (position
coil centrally on clamp)
Loose Rogowski Coil with separate mounting hardware: The coil
and mounting hardware are separate. The coil comes with the
two wire leads for connection to a terminal block.

58
Current Product
Type Envelope Rating (A) Number
110
400 G04HNRCE
Remark: for ratings > 4000A two coils are used
600/630 G07HNRCE
800 G08HNRCE
1 1000 G10HNRCE Neutral Rogowski
1200/1250 G13HNRCE External
1600 G16HNRCE
2000 G20HNRCE
400 G04MNRCE
600/630 G07MNRCE
Encased with 800 G08MNRCE
Terminal Screws 1000 G10MNRCE
2 1200/1250 G13MNRCE
1600 G16MNRCE
2000 G20MNRCE
2500 G25MNRCE
3000/3200 G32MNRCE
3000/3200 (1600 x 2) G32LNRCE
4000 (2000 x 2) G40LNRCE
3
5000 (2500 x 2) G50LNRCE
6000/6400 (3200 x 2) G64LNRCE
400 G04HNRC
600/630 G07HNRC
800 G08HNRC
1 1000 G10HNRC
1200/1250 G13HNRC
1600 G16HNRC
2000 G20HNRC
400 G04MNRC
Loose Rogowski 600/630 G07MNRC
Coil and 800 G08MNRC
Mounting 1000 G10MNRC
Hardware 2 1200/1250 G13MNRC
1600 G16MNRC
2000 G20MNRC
2500 G25MNRC
3000/3200 G32MNRC
3000/3200 (1600 x 2) G32LNRC
4000 (2000 x 2) G40LNRC
3
5000 (2500 x 2) G50LNRC
6000/6400 (3200 x 2) G64LNRC

Rev. 11/13 www.geindustrial.com BuyLog Catalog 8-19


Data subject to change
without notice
Low Voltage Power & Insulated Case Circuit Breakers Section 8

EntelliGuard G Low Voltage Power Circuit Breakers
EntelliGuard G Accessories

Door Escutcheon Kit for IP54 Protection


An optional complete IP54 front door panel is available when a
higher degree of protection is needed.

Product
Description Number
Door Escutcheon Kit - IP54 Door Panel - Fixed/ Drawout G54DR

Mechanical Operations Counter IP54 Door Escutcheon


Used with either manual or motor charged circuit breakers, the
counter provides an accurate record of the cumulative number of
complete breaker closing operations.

Product
Description Number
Mechanical Operations Counter GMCNR

Door Interlock Kit


A door interlock mechanism may be fitted inside the cassette on
the right for Left hinged door or Left for Right hinged door. Specify Mechanical Operations
whether door is Left hand or Right hand hinged when ordering. Counter
Door interlock is different for a cassette with side mounted
secondary disconnect.

Product
Description Number
Door Interlock (Left Side) GLHD
Door Interlock (Right Side) GRHD

Front Flat Terminations


The EntelliGuard G Fixed mounted breaker comes standard Door Interlock Kit
with Back Connected Terminations. Optional Front Flat
terminations are available for front access mounting.

Product
Description Number
Env1 800 - 2000A, Type N&H, Flat Front UL489, GBB1TBF3
Fixed 3 Pole Breaker Bus Bar Terminations (Top/Bottom)
Env1 800 - 2000A, Type N&H, Flat Front UL489, GBB1TBF4
Fixed 4 Pole Breaker Bus Bar Terminations (Top/Bottom)
Env2 800A - 3000A Flat Front UL489 Fixed 3 Pole GBB2TBF3
Breaker Bus Bar Terminations (Top/Bottom)
Env2 800A - 3000A Flat Front UL489 Fixed 4 Pole GBB2TBF4
Breaker Bus Bar Terminations (Top/Bottom)
Env3 4000-6000A Flat Front UL Fixed 3 Pole GBB3TBF3
Breaker Bus Bar Terminations (Top/Bottom)
Env3 4000-6000A Flat Front UL Fixed 4 Pole
GBB3TBF4
Breaker Bus Bar Terminations (Top/Bottom)

Front Flat Terminations

8-20 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Low Voltage Power & Insulated Case Circuit Breakers Section 8

EntelliGuard G Low Voltage Power Circuit Breakers
EntelliGuard G Accessories

Arcing Contacts Assembly


Arcing contacts are supplied with the EntelliGuard breaker.
Product
Description Number
Ent. Grd 1p EG1 H Type G20HARC
Ent. Grd 1p EG1 S&N type G20NARC
Ent. Grd 1p EG2 H&M type G40MARC
Ent. Grd 1p EG2 E&N type G40NARC
Ent. Grd 1p EG33200-6400A G64LARC

Contact Wear Indicator


The contact wear indicator is a simple device that allows the user
to establish if the main contacts need replacement. It can be
used on devices of the fixed pattern (if the arc chutes can be
removed) and on devices of the draw out pattern.
Product
Description Number
Contact Wear Indicator GCNTW

Racking Handle
A collapsible Racking Handle is provided to rack in/out the draw
out breakers whenever needed.

Product
Description Number
Racking Handle GRHNR

Back Connected Terminations Fixed Envelope


Terminal assemblies are supplied with the EntelliGuard
breaker. Fixed breakers have back or front connected
terminations available.
Product
Envelope Size Description Type Number
3 Pole GBB116TBB3
Up to 1600A
4 Pole GBB116TBB4
1
3 Pole GBB120TBB3
200A
4 Pole GBB120TBB4
3 Pole GBB220TBB3
Up to 2000A
4 Pole GBB220TBB4
3 Pole GBB230TBB3
3000A UL
4 Pole GBB230TBB4
2
3 Pole (Top Side) GBB232TBB3
3 Pole (Bottom Side) GBB232BBB3
3200A ANSI
4 Pole (Top Side) GBB232TBB4
4 Pole (Bottom Side GBB232BBB3
3 Pole GBB340TBB3
up to 4000A
4 Pole GBB340TBB4
3 Pole (Top Side) GBB360TBB3
3
3 Pole (Bottom Side) GBB360BBB3
6000A
4 Pole (Top Side) GBB360TBB4
4 Pole (Bottom Side) GBB360BBB4

Rev. 11/13 www.geindustrial.com BuyLog Catalog 8-21


Data subject to change
without notice
Low Voltage Power & Insulated Case Circuit Breakers Section 8

EntelliGuard G Low Voltage Power Circuit Breakers
EntelliGuard G Accessories

Back Connected Terminations For Cassette


Product
Envelope Size Description Type Number
3 Pole GBB216TBBC3
Up to 1600A
4 Pole GBB216TBBC4
1
3 Pole GBB220TBBC3
200A
4 Pole GBB220TBBC4
3 Pole GBB216TBBC3
Up to 1600A
4 Pole GBB216TBBC4
3 Pole GBB220TBBC3
Up to 2000A
4 Pole GBB220TBBC4
3 Pole GBB230TBBC3
2 3000A UL 4 Pole GBB230TBBC4
3 Pole (Top Side) GBB232TBC3
3 Pole (Bottom Side GBB232BBC3
3200A ANSI
4 Pole (Top Side) GBB232TBC4
4 Pole (Bottom Side GBB232BBC4
3 Pole (Top Side) GBB360TBC3
Envelope 1 and 2, 3 Pole
3 Pole (Bottom Side) GBB360BBC3
3 6000A 1600A
4 Pole (Top Side) GBB360TBC4
4 Pole (Bottom Side) GBB360BBC4

Cluster Pad
Product
Envelope Size Description Number
1 Cluster Pad (set per phase) Qty 2 per GBB120TBD
Cluster Pad (single cluster) 2000A Qty 2 per GBB220TBD
2
Cluster Pad (double cluster) 2500A - 3200A Qty 2 per GBB232TBD
3 Cluster Pad Qty 2 per GBB360TBD

Envelope 2, Cluster Pad


Cluster (Single Cluster) 2000A
Product
Envelope Size Description Number
1 36 finger (95x20 mm) Qty 1 G20NCLS
36 finger (95x20 mm) Qty 1 G20MCLS
2
36 finger (95x15 mm) Qty 1 G32ECLS
3 36 finger (95x15 mm) Qty 1 G64LCLS

Fixed Secondary Disconnect (Breaker Mounted)


Fixed breakers are always supplied with a secondary disconnect
(auxiliary connection block) suitable for 39 connection points
(terminal A). When the number of factory installed accessories
exceeds the available number of connection points needed,
a 2nd connection block is automatically added (terminal B).
For cases where the accessories are mounted in the field, an
additional auxiliary connection block can be added to provide
39 more connections.

Product
Description Number
Fixed Breaker Top Mounted Secondary Disconnect, GSDFTR1
39 Pole Male/Female
Fixed Breaker Top Mounted Secondary Disconnect, GSDFTR2
78 Pole Male/Female
Fixed Breaker Side Mounted Secondary Disconnect, GSDFSR
78 Pole Male/Female

8-22 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Low Voltage Power & Insulated Case Circuit Breakers Section 8

EntelliGuard G Low Voltage Power Circuit Breakers
EntelliGuard G Accessories

Network Interlock Device (NI)


The Network Interlock Device locks the breaker in the OFF
position electrically and mechanically. When this device receives
a pulse all local breaker functionality is disabled, except the trip-
ping of the device on any over current fault. On the receipt of a
2nd pulse normal operation is re-instated. The presence of mains
power does not affect the locking and/or re-instatement of this
device. Each device has a local RESET button that only can be
accessed after breaker cover removal.
Product
Description Number
Network Interlock 120V, UL Listed GNTK120R

Remote Racker
The Remote Racking Operator allows the user to move a draw
out circuit breaker between the CONNECT and DISCONNECT posi-
tions via an electric racking gear head motor and the cassette
housing the breaker. The remote racking operator requires
115Vac, 60Hz control power. A control box connected
to the operator with a thirty-foot cord permits control from a
remote location.
Product
Description Number
Remote Racker EGGRRLV

Lifting Devices
Product
Poles Frame Number
3 1 and 2 GLD3F12
3 3 GLD3F3
4 1 and 2 GLD4F12
4 3 GLD4F3
ACB Lifting Truck ACBLIFT Frame 1 & 2,
For more accessories and options, see the EntelliGuard G Application Guide
3 Pole
DET-653B.

Frame 3, Frame 1 & 2, Frame 3,


3 Pole 4 Pole 4 Pole

Rev. 11/13 www.geindustrial.com BuyLog Catalog 8-23


Data subject to change
without notice
Low Voltage Power & Insulated Case Circuit Breakers Section 8

WavePro Circuit Breakers with EntelliGuard TU, Power+, Enhanced
MicroVersaTrip Plus and MicroVersaTrip PM Trip Unit Systems
Instantaneous Protection
Instantaneous pick up is adjustable up to 15 times plug rating
on every circuit breaker and, optionally, up to 30 times on
some breakers.
A separately adjustable fast instantaneous trip useful for
when the circuit must provide the best possible protection and
arc flash performance while sustaining normal load
An override instantaneous provides fast tripping for the largest
bolted fault currents to minimize potential damage.
Up to 17 Short Time bands allow you to set your circuit breaker
to sustain load requirements without slowing protection.
Ground Fault Alarm via I/O, or
Ground fault protection with faster time bands, multiple slopes
There are four trip unit systems available for WavePro Low and the ability to coordinate a 1200A ground fault with an 800A
Voltage Power Circuit Breakers EntelliGuard TU, Power+, circuit breaker a ratio four times better than in previous
Enhanced MicroVersaTrip Plus and MicroVersaTrip PM. All four generation trip units
systems consist of the trip unit, the trip actuator, current sensors
and rating plugs. The term trip unit systems applies to the Maintenance and Diagnostics
combination of these four components, which form the circuit Universal spare trip unit that will fit any GE circuit breaker
breaker solid-state tripping system. Universal trip plug fits any trip unit
Flexible serial communication via Modbus RTU
The EntelliGuard TU Trip Unit is the latest addition to the list of Integrates directly into GEs EnerVista Power Management System
trip units available on GE low voltage power circuit breakers. The Health status via breaker LED indicating normal operation,
new functions offered by the trip unit enhance the WavePro errors, pickup, and trips while providing non-volatile memory
breaker with Waveform Recognition Instantaneous which with a continuous self-testing microprocessor
improves coordination with current limiting devices and reduces Lithium battery to eliminate need for external power
nuisance trips by discerning whether a downstream breaker/fuse 10 event Log with Date/Time Stamp: Stores the last 10 events.
is clearing the fault. The unit also provides optimum circuit safety Date/Time with 24VDC Power.
and arc flash protection with the Reduced Energy Let Through, Thermal Memory
providing a faster instantaneous trip that may be used in case WaveForm Capture: 40 Samples/Cycle, 4 cycles prior and 4
faster and more sensitive protection is temporarily required. Its cycles post event in COMTrade format
Zone Selective Interlocking provides the ability to overlap the Large backlit LCD with detailed, easy to see descriptions
Instantaneous on the Main and Feeder breakers and the
EntelliGuard TU also has Flexible Time Current Curves:
44 Long Time Shapes (I2T and I4T (fuse)), 3 Short Time I2T slopes,
Short Time adjustable in 55 msec increments and a Selective
Ground Fault curve.

All of the new functions and features in the new EntelliGuard TU


trip unit provide ultimate system reliability and selectivity without
sacrificing circuit protection.

Designed for Flexibility


A wide range of continuous adjustment Long Time delays
ensure the circuit breaker can be exactly dialed in to your
selectivity and protection needs.
Multiple Short Time diagonal bands tune your protection to
exactly where it needs to be.
Flexible time current settings and curves Standard Long Time
characteristics exactly mimic the curve of a thermal magnetic
circuit breaker.
Flexible Time Current Curves: 44 Long Time Shapes (I2T and I4T
(fuse)), 3 Short Time I2T slopes, Short Time adjustable in 55 msec
increments, a Selective Ground Fault curve

8-24 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Low Voltage Power & Insulated Case Circuit Breakers Section 8

WavePro Circuit Breakers with EntelliGuard TU, Power+, Enhanced
MicroVersaTrip Plus and MicroVersaTrip PM Trip Unit Systems
The Power+ trip unit continues to use GEs proven technique of Standard Functions:
measuring true rms currents of both sinusoidal and harmonically Rating plug with test port
distorted waveforms. The frequent sampling (48 times per cycle Protection
per phase) allows precise calculations of true rms current. The Long-time, Instantaneous (Instantaneous may be omitted
sampling rate allows waveform measurements up to the 11th when short-time is provided)
harmonic. True rms sensing avoids potential under- or over-pro-
tection problems associated with peak-sensing tripping systems. Optional Functions:
Protection
Short-time protection, with selectable l2t
The Power+ trip unit is identified by its plug-in modules and rotary
switches. The optional target module provides LED targets for Ground fault protection, with selectable l2t
overload, short circuit and ground fault trips. View and Reset push Defeatable ground fault (not UL)
buttons are also provided to monitor status, including a battery Target Module
check LED. Standard 3-volt lithium batteries in the target module View and Reset buttons
power the indicating LEDs (batteries are not required for trip unit
Battery check LED
operation). The rating plug module serves the dual purpose of
Longtime pickup/trip unit health LED
establishing the trip rating for the circuit breaker as well as
LEDs for overload, short circuit, ground fault trips
providing ground fault protection when required. All pickup and
delay settings are selected with detented rotary switches.

Enhanced MicroVersaTrip Plus Standard Functions:


and MicroVersaTrip PM trip Rating plug with test port
units also measure true rms Protection
currents (and voltages for Long-time, Instantaneous (Instantaneous may be omitted
MicroVersaTrip PM trip units). when short-time is provided)
The higher sampling rate (64 Status
times per cycle) allows wave- Trip target (trip type)
form measurements up to Trip information (magnitude and phase)
the 31st harmonic to achieve Trip operations counters
accuracy of 99%. Metering Display
MicroVersaTrip Plus and Phase current (selectable among phases)
MicroVersaTrip PM trip units Optional Functions:
contain a digital liquid crystal
Short-time protection, with selectable l2t
display with a five-button keypad for local setup and readout of trip
Ground fault protection, with selectable l2t
settings. The trip units have a lithium battery for cold setup capability
Defeatable ground fault (not UL)
and viewing of targets without external power. The LCD and keypad
Switchable instantaneous/short-time and ground fault (not UL).
also provide a three-phase ammeter and trip indicators.
Zone-selective interlock, for ground fault only or for both ground
The Enhanced MicroVersaTrip (MVT) PM trip unit adds power fault and short-time protection.
management system capability, including advanced metering and
protective relaying, to the basic functions of the MVT Plus. The Additional Functions available only with MicroVersaTrip PM trip unit:
MVT PM can be interfaced with either Modbus RTU or Ethernet Communication and metering (M-option)
TCP/IP compatible systems. Communication, metering and protective relaying (PM-option)
All trip units utilize a series of interchangeable rating plugs to
establish the current rating of the breaker. Communication:
Remote communication with POWER LEADER
Power Management Control System (PMCS) software
Metering:
Voltage (V), Energy (kWh/MWh/GWh)
Real Power (kW/MW), Total Power (kVA/MVA)
Demand Power (kW/MW), Peak demand power (kW/MW)
Frequency (Hz)
Protective Relaying:
Undervoltage, Overvoltage
Voltage unbalance, Current unbalance, Power reversal

Rev. 11/13 www.geindustrial.com BuyLog Catalog 8-25


Data subject to change
without notice
Low Voltage Power & Insulated Case Circuit Breakers Section 8
WavePro Low Voltage Power Circuit Breakers
How to select WavePro low voltage power submitting your order. Heres an example of the selection based on
circuit breakers One step at a time a WavePro breaker with the following specifications: digits with X
This selection guide allows you to systematically arrive at the product indicate no option or accessory. Example is on pages 8-26 through
number for a WavePro OEM breaker. It also contains information you 8-28. Breaker selection starts on page 8-33. An alternative to
can use to specify applicable fuses, neutral current transformers and developing the breaker product number and pricing manually is to
other associated devices (Tables A-1 to A-4 on pages 8-30 and 8-31 generate the same information electronically via the web wizards at
www.geindustrial.com/industrialsystems/wizards/peb_oem_am/home.htm
and Tables B-5 to B-12 on pages 8-44 and 8-45) and to select and
order substructures and substructure accessories (Tables B-1 to B-4
on pages 8-40 to 8-44). The WavePro Breaker Application Guide (DET- Short Circuit Ratings RMS Symmetrical
167) contains additional information that will help you select options Rated kA
AC
to specify for your particular application. Voltage Frame With Without
Nominal Breaker Size Short-Time Instantaneous Instantaneous
First, determine the appropriate WavePro breaker type from Table (Max.) Type (amps) Withstand Trip Trip
A-1 on page 8-30. WPS-08 800 30 30 30
WPH-08 800 42 42 42
Using that information, follow the step-by-step instructions begin-
ning on page 8-33 to select options and accessories. At the end WPX-08 800 65 65 65

of each step, transfer the resulting product number digit(s) for WPS-16 1600 50 50 50

your selection to the appropriate boxes in the Product Number WPH-16 1600 65 65 65

Line. Helpful Hint: Make a photocopy of the Product Number Line WPS-20 2000 65 65 65
480
(page 8-29) every time you follow this process so you can use the (508)
WPS-32 3200 65 65 65

form again. WPH-32 3200 85 85 85


WPX-32 3200 100 100 100
When youre done, youll have a complete breaker product number.
WPS-40 4000 85 85 85
Note: To order, you must submit a complete 15-digit breaker
WPX-40 4000 100 100 100
product number. If you reach a point where no further options or
WPS-50 5000 85 85 85
accessories are required, fill in each of the remaining product
WPX-50 5000 100 100 100
numbers digits with X (indicating no option or accessory) before

Note: See WavePro configurator for pricing. Contact a sales representative for configurator.
Example
Option or Accessory Option or Accessory
Tables A-1 to A-4 WPF-08 Breaker, 800A Frame Step 6 240V, 50/60 Hz electric lockout
Step 1 800A Class L Fuse, 800A Sensor Step 7 4-stage aux switch
Step 2 MVT PM Trip Unit with LSIG functions Step 8 Bell alarm with lockout
Step 3 700A Trip Unit Rating Plug Step 9 24V dc shunt trip (second shunt trip)

Step 4 120V ac 60Hz Electrical Charge & Close Operation Step 10 Hidden close push button and remote charge indicator
(Note: A disconnect comes standard with the options selected here.)
Step 5 120V ac shunt trip, 60 Hz

Product Number Line WavePro Breaker (Example)


WavePro Future use
Breaker for but "X"
Substructures Step 1 Step 2 Step 3 Step 4 Step 5 Step 6 Step 7 Step 8 Step 9 Step 10 required
W S G D C Q E F 1 5 A B B E X

Step 1 Select Interrupting Type and Current Sensor (Example) GO TO STEP 2 ON PAGE 8-27
Current Sensor
Breaker Interrupting
Type Type & Rating No Sensor1 150A 400A 800A
WPS-08 Standard 1A 1B 1C 1D
WPH-08 High 2A 2B 2C 2D
WPX-08 Extended 3A 3B 3C 3D
300A Fuse AB AC AD
350A Fuse BB BC BD
400A Fuse CB CC CD
Class J
Fuse 450A Fuse DB DC DD
500A Fuse EB EC ED
WPF-08
600A Fuse FB FC FD
800A Fuse GB GC GD
1000A Fuse HB HC HD
Class L
Fuse 1200A Fuse JB JC JD
1600A Fuse KB KC KD

8-26 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Low Voltage Power & Insulated Case Circuit Breakers Section 8
WavePro Low Voltage Power Circuit Breakers
Step 2 Select Trip Unit (Example)
Functions EntelliGuard Trip Unit MicroVersaTrip Plus MicroVersaTrip M MicroVersaTrip PM
Defeatable Switchable
Function Long Short Instanta- Ground Ground S T or ZSI-GF
Code Time Time neous Fault 1 Fault 1 Inst & GF 1 ZSI-G F & ST Product No. Digits Product No. Digits Product No. Digits Product No. Digits
LI GA AJ BJ CJ
LIG GB AK BK CK
LIGZ1 GC AL BL CL
LIGD2 GD AM BM CM
LIGDZ12 GE AN BN CN
LS GF AA BA CA
LS G GH AB BF CC
LSGZ1 GK AA BA CA
LSGZ2 GL AD BD CD
LSGD 2 GM AE BE CE
LSGDZ12 GN AF BF CF
LSGDZ22 GP AG BG CG
LSI GQ AP BP CP
LSIG GR AQ BQ CQ
LSIGX GS AR BR CR
LSIGZ1 GT AS BS CS

Step 3 Select Trip Unit Rating Plug By Current Sensor (Example)


Example only - ordering information
starts on page 8-33.
MicroVersaTrip Plus
Availibility by Current Sensor Rating (shaded areas indicate availibility)
EntelliGuard TU and Enhanced MicroVersaTrip
Product No. Trip Unit PM Trip Unit Power+ Rating Plug 150 400 800 1600 2000 3200 4000 5000
X None
1 60 1, 2

2 80
3 100
4 125 1

5 150 1, 2

6 200
7 225
8 250
9 300 1, 2

A 400
B 450 1, 2

C 500
D 600 1, 2

E 700
F 750 1, 2

G 800 1, 2

H 1000
J 1100 1, 2

K 1200
L 1500 1, 2

M 1600
N 2000
P 2400
Q 2500
R 3000
S 3200 1, 2

T 3600 1, 2

V 4000 1, 2

W 5000 1, 2

1At coordinate indicated, rating plug and current sensor combination available only on MicroVersaTrip trip units. Not available on Power+ trip units.
2At coordinate indicated, rating plug and current sensor combination available only on EntelliGuard TU trip units. Not available on Power+ trip units.

Rev. 11/13 www.geindustrial.com BuyLog Catalog 8-27


Data subject to change
without notice
Low Voltage Power & Insulated Case Circuit Breakers Section 8
WavePro Low Voltage Power Circuit Breakers

Step 4 Select Charge and Close Operators (Example) Step 9 Select Second Shunt Trip (Example)
Manual Charge, Electrical Charge
(not available with WPS-50 5000A breakers)
Manual Remote Close & Close
Product Product Product Voltage Product Number Digit
Number Number Number
Voltage Digit Digit Digit None X
Manual X 120V, 60Hz 1
120V, 60 Hz 1 F 240V, 60Hz 3
120V, 50 Hz 4 H 24Vdc B
120V, 50/60 Hz-48Vdc N 110/125Vdc E
240V, 60 Hz 3 T
240V, 50 Hz 6 W Step 10 Select Additional Options (Example)
48Vdc A E
A-Disconnect Hidden Close Operation Remote Charge Product No.
110Vdc B P PM Ready Push Button Counter Indicator Digit
125Vdc C Q X (none)
A
Step 5 Select Shunt Trip (Example) B
C
Voltage Product Number Digit D
None X E
120V, 60 Hz 1 F
208V, 60 Hz 2 G
240V, 60 Hz 3 H
70V, 60 Hz 4 J
120V, 50 Hz 5 K

208V, 50 Hz 6 L
M
Step 6 Select Undervoltage Trip OR Electric Lockout (Example) N
P
Undervoltage Undervoltage
(Instantaneous) with Time Delay Electric Lockout
Product Product Product Example only - ordering information starts on page 8-33.
Number Number Number
Voltage Digit Digit Digit Note: See WavePro configurator for pricing. Contact a sales
None X X X representative for configurator.
120V,
1 4
50/60 Hz
208V,
3
50/60 Hz
240V,
2 3 5
50/60 Hz
24Vdc A G
48Vdc B H
110Vdc C J
125Vdc C E J

Step 7 Select Auxiliary Switch (Example)

Auxiliary Switch Product Number Digit


None X
4-stage Auxiliary Switch A

Step 8 Select Bell Alarm (Example)

Bell Alarm Product Number Digit


None X
Bell Alarm A
Bell Alarm with Lockout B

8-28 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Low Voltage Power & Insulated Case Circuit Breakers Section 8
WavePro Low Voltage Power Circuit Breakers

Ordering Worksheet

The step-by-step process below allows you to systematically Follow the instructions at each step and transfer the product
arrive at the product number for your WavePro OEM breaker. As a number digit for each selection to the appropriate boxes in the
result, you will get exactly what you need. In addition, this system Product Number Line below. Note: You must submit a complete
reduces the cycle time, precisely specifies your requirements, 15-digit product number when ordering. If you reach a point
allows tracking during production and ensures accurate invoicing. where no further options or accessories are desired, fill in the
The final product number will appear on the breaker nameplate, remaining product number digits with X (for none).
so you can identify all components built into the original breaker For options not listed, contact your GE Sales Engineer or
and compare breakers within a facility for proper application. GE Switchgear Marketing for assistance.

Product Number LineWavePro Breaker


WavePro Breaker Future use, but
for Substructures Step 1 Step 2 Step 3 Step 4 Step 5 Step 6 Step 7 Step 8 Step 9 Step 10 "X" required
W S X

Note: Photocopy this page for each breaker you select and
Date submit it with your order.
Name

Title

Company

Address

City

State

Zip

Telephone

Fax

Note: See WavePro configurator for pricing. Contact a sales


representative for configurator.

Rev. 11/13 www.geindustrial.com BuyLog Catalog 8-29


Data subject to change
without notice
Low Voltage Power & Insulated Case Circuit Breakers Section 8
WavePro Low Voltage Power Circuit Breakers
Basic Selection Information

Table A-1.
WavePro Interrupting Ratings (50/60 Hz ac)
Short-Circuit RMS Symmetrical kA
Rated AC Voltage,
Nominal (max) Breaker Type Frame Size (amps) Short-Time Withstand With Instantaneous Trip Without Instantaneous Trip
WPS-08 800 30 30 30
WPH-08 800 42 42 42
WPX-08 800 50 50 50
WPS-16 1600 42 42 42
WPH-16 1600 65 65 65
WPS-20 2000 65 65 65
600 WPS-32 3200 65 65 65
(635)
WPH-32 3200 85 85 85
WPX-32 3200 85 85 85
WPS-40 4000 85 85 85
WPX-40 4000 85 85 85
WPS-50 5000 85 85 85
WPX-50 5000 85 85 85
WPS-08 800 30 30 30
WPH-08 800 42 42 42
WPX-08 800 65 65 65
WPS-16 1600 50 50 50
WPH-16 1600 65 65 65
WPS-20 2000 65 65 65
480 WPS-32 3200 65 65 65
(508)
WPH-32 3200 85 85 85
WPX-32 3200 100 100 100
WPS-40 4000 85 85 85
WPX-40 4000 100 100 100
WPS-50 5000 85 85 85
WPX-50 5000 100 100 100
WPS-08 800 30 42 30
WPH-08 800 42 50 42
WPX-08 800 50 65 50
WPS-16 1600 50 65 50
WPH-16 1600 65 65 65
WPS-20 2000 65 65 65
240 WPS-32 3200 65 85 65
(254)
WPH-32 3200 85 130 85
WPX-32 3200 100 130 100
WPS-40 4000 85 130 85
WPX-40 4000 100 130 100
WPS-50 5000 85 130 85
WPX-50 5000 100 130 100

Table A-2.
Fused Breaker Ratings. Max. 600V ac 50/60 Hz.
Fuse Rating (Amps) 1
Interrupting Rating rms
Frame Size (Amps) Min Max Symmetrical kA Breaker Type
800 300 1600 200 WPF-08
1600 450 2500 200 WPF-16
2000 2000 2500 200 WPS-20 2
3200 2000 4000 200 WPS-32 2
4000 2000 5000 200 WPS-40 2
5000 2000 5000 200 WPS-50 2
1
The maximum fuse rating is the largest fuse that tests show will result in proper performance of the breaker and fuse in combination under short circuit conditions.
2
Fuses are mounted on separate fuse roll-out element and are ordered and shipped separately. See Table A-4 on page 8-31.

8-30 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Low Voltage Power & Insulated Case Circuit Breakers Section 8
WavePro Low Voltage Power Circuit Breakers
Basic Selection Information (continued)

Table A-3.
Allowable Fuse Sizes for WavePro WPF and WPS breakers with separate fused rollout elements.
Note: WPS breakers with separate fuse roll-out element require the open fuse lockout (OFLO) device. Select OFLO only option for
breakers 2000A-5000A: The OFLO option is standard on WPF breakers.
Ferraz-Shawmut Fuse Range (Amps) 1
Darkened areas indicate available fuse ranges
Class J Class L
Breaker Frame
Type Size Sensor Rating Rating Plug 300 350 400 450 500 600 800 1000 1200 1600 2000 2500 3000 4000 5000
150A Below 150A
150A, 400A 150A
400A 225A
400A, 800A 300A
WPF-08 800A
400A, 800A 400A
800A 600A
800A 700A
800A 800A
800A 400A & below
800A 500A
800A, 1600A 600A
800A, 1600A 700A
WPF-163 1600A
800A, 1600A 800A
1600A 1000A
1600A 1200A
1600A3 1600A3
WPS-20 2 2000A 2000A 2000A & below
WPS-32 2 3200A 3200A 3200A & below
WPS-40 2 4000A 4000A 4000A & below
WPS-50 2 5000A 5000A 5000A & below
1 Class L fuses less than 800A are not UL or CSA listed. Use Class J fuses for 600A and below. 800A-2000A fuses are also available as welder limiters.
2 Fuses are mounted on separate fuse roll-out element and are ordered and shipped separately. See Table B-3 on pages 8-41 to 8-42.
3 Integrally fused 1600A frame breakers (WPF-16) equipped with 2500A fuses can be furnished with rating plugs from 300-1600A. Breakers equipped with
2500A fuses cannot be modified to accept lower rated fuses. WPF-16 breakers equipped with 2000A and lower fuses cannot be upgraded to 2500A fuses.
The maximum trip rating for a WPF-16 breaker is 1200A when furnished with other than 2500A fuses (see chart for min-max fuse rating for each rating
plug value). 2500A fuses preclude the use of shutters in the breaker cubicle.

Table A-4. Class L Fuses for Roll-out Elements on 2000A, 3200A, 4000A
Product Numbers for Replacement Fuses and 5000A Frames
Note: These product numbers are for field-installed replacement (replace original customer-installed fuses)
fuses. Original fuses for 800A and 1600A frame breakers are Fuse Rating Product Number
integral to the breaker and are factory installed. For larger frame 2000A A4BY2000-55BA
breakers (2000A and greater), customers must provide and sepa- 2500A A4BY2500-55BA
rately mount fuses. 3000A A4BY3000-55BA

Class J & Class L Breaker Mounted Fuses for 800A 4000A A4BY4000-55BA
5000A A4BY5000-55BA
and 1600A Frames
(replace original GE-installed fuses)
Fuse Class Fuse Rating Product Number Welder Limiters for Breaker Mounted Fuses
J 300A A4J300 (replace original GE-installed fuses)
J 400A A4J400
Fuse Rating Product Number
J 450A A4J450
J 500A A4J500 800A A4BX800

J 600A A4J600 1600A A4BX1600BG

L 800A A4BY800 2000A A4BX2000

L 1000A A4BY1000BG
L 1200A A4BY1200BG
L 1600A A4BY1600BG
L 2000A A4BY2000
L (Silver) 2500A A4BQ2500GE

Rev. 11/13 www.geindustrial.com BuyLog Catalog 8-31


Data subject to change
without notice
Low Voltage Power & Insulated Case Circuit Breakers Section 8
WavePro Low Voltage Power Circuit Breakers

EntelliGuard TU Trip Unit Characteristics


Long Time Short Time
Frame Max. Sensor Rating Current Setting (C) (Pick-Up) Delay (Seconds)1 Pick-up (Multiple
Envelope Size Ampere Rating (Amperes) (S) Multiple of Rating Plug Amperes (X) Fuse Type (F-Bands) Thermal Type (C-Bands) of Current Settings) (C) Delay (Seconds)
0.025 0.20
800 800 200, 400, 800 0.025 0.60
0.025 1.21
0.032 1.61 I2T in
0.044 2.41 0.401
1600 1600 800, 1000, 1600
0.059 3.21
0.078 4.02
0.10 4.82
0.5 thru 1.0 in 0.13 5.62 1.5 thru 9.0 in
2000 2000 2000
Increments of 0.05 0.17 6.43 Increments of 0.05
0.22 7.23
0.27 8.04
2500 1000, 2000, 2500 0.35 9.64
3000 0.44 11.20
0.55 12.90 I2T out
3000 3000
0.69 14.50 0.10, 0.21, 0.352
0.87 16.10
4000 4000 4000 1.10 17.70
19.30

Trip Unit Characteristics (continued)


Adjutable Instantaneous Adjustable Instantaneous High Range Instantaneous Ground Fault
Pick-Up without ST (Multiple Pick-Up with ST (Multiple (Multiple of Frame Pick-Up (Multiple Delay with l2T Delay with l2T
Envelope Size of Rating Plug Amperes) (X) of Rating Plug Amperes) (X) Short Time Rating) (H) of Sensor Ampere Rating) in seconds out seconds3
1.5 thru 10.0 in 1.5 thru 15.0 in 2.0 thru 0.60 in
800 0.10, 0.21, 0.35
0.5 increments 0.5 increments increments of 0.01
1.5 thru 10.0 in 1.5 thru 15.0 in 2.0 thru 0.60 in
1600 0.10, 0.21, 0.35
0.5 increments 0.5 increments 1.0 increments of 0.01 .44 at 200% of
1.5 thru 10.0 in 1.5 thru 15.0 in 1.0 2.0 thru 0.60 in pick-up at lower
2000 0.10, 0.21, 0.35
0.5 increments 0.5 increments increments of 0.01 limit of band
1.5 thru 10.0 in 1.5 thru 13.0 in 2.0 thru 0.37 in
3000 0.10, 0.21, 0.35
0.5 increments 0.5 increments increments of 0.01
1.5 thru 9.0 in 1.5 thru 9.0 in 2.0 thru 0.30 in
4000 0.10, 0.21, 0.35
0.5 increments 0.5 increments increments of 0.01
1Time delay shown at 600% of current setting at lower limit of band.
2Time delay shown at lower limit of each band. All pick-up tolerances are 10%.
3Time delay shown at lower limit of each band. Ground fault pick-up not to exceed 1200 amperes

8-32 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Low Voltage Power & Insulated Case Circuit Breakers Section 8
WavePro Low Voltage Power Circuit Breakers

Selection
Before beginning the selection process, first determine the appropriate WavePro breaker type from Table A-1 on
page 8-30. You will need this information to proceed.

Step 1 Select Interrupting Type And Current Sensor


For WPF breaker types, see Table A-3 on page 8-31 for allowable combinations of fuse size, current sensor and
rating plugs. From the table below that corresponds to your frame size, select the interrupting type and current
sensor for your breaker type. Transfer the product number digits to the box marked Step 1 in the Product
Number Line on the Ordering Worksheet (page 8-29). Note: Power fuses and open fuse lockout (OFLO) devices
are included for WPF type 800 and 1600 amp fused breakers.

800 Amp Frame


Current Sensor

Breaker Type Interrupting Type & Rating No Sensor 1 150A 400A 800A
WPS-08 Standard 1A 1B 1C 1D
WPH-08 High 2A 2B 2C 2D
WPX-08 Extended 3A 3B 3C 3D
300A Fuse AB AC AD
350A Fuse BB BC BD
400A Fuse CB CC CD
Class J Fuse
450A Fuse DB DC DD
500A Fuse EB EC ED
600A Fuse FB FC FD
WPF-08 800A Fuse GB GC GD
1000A Fuse HB HC HD
Class L Fuse
1200A Fuse JB JC JD
1600A Fuse KB KC KD
800A Fuse ND
Welder Limiter
1600A Fuse QD
1 Draw-out breaker only, non-automatic.

1600 Amp Frame

Current Sensor

Breaker Type Interrupting Type & Rating No Sensor 1 800A 1600A


WPS-16 Standard 1E 1F 1G
WPH-16 High 2E 2F 2G
450A Fuse DF

Class J Fuse 500A Fuse EF

600A Fuse FF FG
800A Fuse GF GG
1000A Fuse HF HG
1200A Fuse JF JG
Class L Fuse
WPF-16 1600A Fuse KF KG
2000A Fuse LF LG
2500A Fuse MF MG
800A Fuse NF NG
Welder Limiter 1600A Fuse QF QG
2000A Fuse RF RG
1 Draw-out breaker only, non-automatic.

Rev. 11/13 www.geindustrial.com BuyLog Catalog 8-33


Data subject to change
without notice
Low Voltage Power & Insulated Case Circuit Breakers Section 8
WavePro Low Voltage Power Circuit Breakers
Selection (continued)

Step 1 (continued)
2000 Amp Frame 3200 Amp Frame
Breaker Interrupting No 2000A Breaker Interrupting No 3200A
Type Type Sensor 1 Sensor Type Type Sensor 1 Sensor

Standard 1H 1J Standard 1K 1L
WPS-20 WPS-32
OFLO only 2 4J OFLO only 2 4L
WPH-32 High 2K 2L
WPX-32 Extended 3K 3L

4000 Amp Frame 5000 Amp Frame


Breaker Interrupting No 4000A Breaker Interrupting 5000A
Type Type Sensor 1 Sensor Type Type Sensor
Standard 1M 1N Standard 1R
WPS-40 WPS-50
OFLO only 2 4N OFLO only 2 4R
WPX-40 Extended 3M 3N WPX-50 Extended 3R
1 Draw-out breaker only, non-automatic.
2 Includes OPEN FUSE LOCKOUT (OFLO) device. Use with separate
fuse roll-out element (see TABLE B-2 on page 8-40).

Step 2 Select Trip Unit


From the table below, select your trip unit. Transfer the product number dig-
its to the boxes marked Step 2 in the Product Number Line to the box
marked Step 2 in the Price Column.

EntelliGuard TU Trip Unit Functions


The new EntelliGuard TU Trip Unit includes new functions like the Reduced Let Through Energy Instantaneous (RELT) as well as
Instantaneous Zone Selective Interlocking (I-ZSI).

WavePro Catalog Number - Code 5


ZSI-GF, ZSI-GF, Modbus Data Product No.
ST3 ST & INST. RELT Communication Monitoring Acquisition Relaying Ammeter Digit
X (none -automatic)
N
P
Q
R
S
T
V
W
1
2
3
4
Z
5
6
7
8
9
3Requires zone selective interlock module, Type TIM1 (120Vac control voltage).

8-34 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Low Voltage Power & Insulated Case Circuit Breakers Section 8
WavePro Low Voltage Power Circuit Breakers
Selection (continued)

Step 2 (Cont.)
WavePro Catalog Number - Code 6
Function Long Short Non-Switchable Ground Product No.
Code Time Time Instantaneous Instantaneous Fault1 Digit
LSI P
LSIG Q
LSIGA 1
LSIGDA2 2
LSI2 U
LSIG2 7
LSIGA2 8
LSIGDA3 9
2Switchboard Applications

MicroVersaTrip Trip Unit


All MicroVersaTrip trip units include integral targets and ammeter display. MicroVersaTrip M adds full metering and communica-
tions; MicroVersaTrip PM adds relaying, metering and communications.
Functions MicroVersaTrip Plus MicroVersaTrip PM

Defeatable Switchable
Function Long Short Instanta- Ground Ground ST or Inst ZSI-GF Product Product Product
Code Time Time neous Fault 1 Fault 1,3 & GF 1,3 ZSI-GF 4 & ST 4 No. Digits No. Digits No. Digits
LI AJ BJ CJ
LIG AK BK CK
LIGZ1 AL BL CL
LIGD3 AM BM CM
LIGDZ13 AN BN CN
LS AA BA CA
LSG AB BB CB
LSGZ1 AC BC CC
LSGZ2 AD BD CD
LSGD 3 AE BE CE
LSGDZ13 AF BF CF
LSGDZ23 AG BG CG
LSI AP BP CP
LSIG AQ BQ CQ
LSIGX 3 AR BR CR
LSIGZ1 AS BS CS
LSIGZ2 AT BT CT
LSIGD 3 AV BV CV
LSIGDZ13 AW BW CW
LSIGDZ23 AY BY CY
1 Ground fault is 3-wire/4-wire. If 4-wire ground fault is required, then one of the A-Disconnect options in Step 10 must be selected and the sensor for
the 4th wire (neutral) must be ordered separately. See Table B-5 on page 8-44.
3 Function combination is not UL Listed.
4 Requires zone selective interlock module, Type TIM1 (120Vac control voltage).

Rev. 11/13 www.geindustrial.com BuyLog Catalog 8-35


Data subject to change
without notice
Low Voltage Power & Insulated Case Circuit Breakers Section 8
WavePro Low Voltage Power Circuit Breakers
Selection (continued)

Step 3 Select Trip Unit Rating Plug By Current Sensor


Select your rating plug and current sensor combination. Transfer the product number digit to the box marked Step 3 in the product
number line.
MicroVersaTrip Plus
EntelliGuard TU Availability by Current Sensor Rating (shaded areas indicate availability)
and Enhanced MicroVersaTrip
Product No.Digits Trip Unit PM Trip Unit Power + Rating Plug 150 400 800 1600 2000 3200 4000 5000
X None
1 60 1, 2
2 80
3 100
4 125 1
5 150 1, 2
6 200
7 225
8 250
9 300 1, 2
A 400
B 450 1, 2
C 500
D 600 1, 2
E 700
F 750 1, 2
G 800 1, 2
H 1000
J 1100 1, 2
K 1200
L 1500 1, 2
M 1600
N 2000
P 2400
Q 2500
R 3000
S 3200 1, 2
T 3600 1, 2
V 4000 1, 2
W 5000 1, 2

1At coordinate indicated, rating plug and current sensor combination available only on MicroVersaTrip trip units. Not available on Power+ trip units.
2At coordinate indicated, rating plug and current sensor combination available only on EntelliGuard TU trip units. Not available on Power+ trip units.

Step 4 Select Charge and Close Operators


Select your charge and close options. Transfer the product number digits to the box marked Step 4 in the Product Number Line.

Manual Manual Charge, Remote Close1 Electrical Charge & Close 1


Product No. Product No. Product No.
Charge-Close Voltage Digit Digit Digit

Manually Operated X
120V, 60 Hz 1 F
120V, 50 Hz 4 H
120V, 50/60 Hz - 48Vdc N
240V, 60 Hz 3 T
240V, 50 Hz 6 W
48Vdc A E
110Vdc B P
125Vdc C Q
250Vdc D R
1 Requires the selection of a shunt trip in Step 5 and a 4-stage or higher auxiliary switch in Step 7.

8-36 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Low Voltage Power & Insulated Case Circuit Breakers Section 8
WavePro Low Voltage Power Circuit Breakers

Step 5 Select Shunt Trip


Select your shunt trip. Transfer the product number digit to the box marked Step 5 in the
Product Number Line. (Note: All shunt trips require the selection of a 4- or 7-stage auxil-
iary switch in Step 7. Second shunt trip may be selected in Step 9.)
Product Product
Voltage Number Digit Voltage Number Digit
None X 240V/50 Hz 7
120V, 60 Hz 1
208V, 60 Hz 2 24Vdc B
240V, 60 Hz 3 48Vdc D
70V, 60 Hz 4 110/125Vdc E
120V, 50 Hz 5 250Vdc F
Shunt Trip
208V, 50 Hz 6

Step 6 Select Undervoltage Trip OR Electric Lockout


Select your undervoltage trip or electric lockout option. Transfer the product number
digit to the box marked Step 6 in the Product Number Line.
Undervoltage with
Undervoltage (Instantaneous) Time Delay 1 Electric Lockout
Product Product Product
Voltage Number Digit Number Digit Number Digit
None X X
120V, 50/60 Hz 1 4
208V, 50/60 Hz 32
240V, 50/60 Hz 2 33 5
24Vdc A G
48Vdc B H
Undervoltage Trip/Electric Lockout
110Vdc C J
125Vdc C E4 J
250Vdc D F5 K
1 Time delay module is provided as a separate component.
2 Order static time delay TAKYUVT5 separately. See Table B-6 on page 8-44.
3 Order static time delay TAKYUVT4 separately. See Table B-6 on page 8-44.
4 Order static time delay TAKYUVT1 separately. See Table B-6 on page 8-44.
5 Order static time delay TAKYUVT2 separately. See Table B-6 on page 8-44.

Step 7 Select Auxiliary Switch


Select your auxiliary switch option. Transfer the product number digit to the box marked
Step 7 in the Product Number Line.

Auxiliary Switch Product No. Digit


None X
4-stage Auxiliary Switch A
7-stage Auxiliary Switch B

Step 8 Select Bell Alarm/Push Button Cover


Auxiliary Switch
Select your bell alarm option. Transfer the product number digit to the box marked Step 8
in the Product Number Line.

Bell Alarm Push Button Cover Product No. Digit


None None X
Bell Alarm None A
Bell Alarm with Lockout None B
None CLOSE PB Cover C
Bell Alarm CLOSE PB Cover D
Bell Alarm with Lockout CLOSE PB Cover E
None OPEN PB Cover F
Bell Alarm OPEN PB Cover G Bell Alarm
Bell Alarm with Lockout OPEN PB Cover H
None CLOSE & OPEN PB Cover J
Bell Alarm CLOSE & OPEN PB Cover K
Bell Alarm with Lockout CLOSE & OPEN PB Cover L

Rev. 11/13 www.geindustrial.com BuyLog Catalog 8-37


Data subject to change
without notice
Low Voltage Power & Insulated Case Circuit Breakers Section 8
WavePro Low Voltage Power Circuit Breakers

Step 9 Select Second Shunt Trip


If you selected a shunt trip in Step 5 and require another, select
your second shunt trip option. Transfer the product number digit
to the box marked Step 9 in the Product Number Line.
Note: Second shunt trip requires the selection of a 7-stage auxil-
iary switch in Step 7.

Voltage Product No. Digit


None X
120V, 60 Hz 1
240V, 60 Hz 3
24Vdc B
110/125Vdc E
250Vdc F

Step 10 Select Additional Options


Select your combination of additional options. Transfer the product number digit to
the box marked Step 10 in the Product Number Line.

A-Disconnect 1 Hidden Close Operation Remote Charge


PM Ready Push Button 2 Counter Indicator Product No. Digit
X (none)
A
B
C
D
E
F
G
H
J
K
Optional Hidden Close
L
button feature shown
1 The 36-point A-Disconnect is automatically supplied if any of the following options were selected in
previous steps:
zone selective interlock
shunt trip
auxiliary switch
bell alarm
undervoltage trip
electrical lockout device
electric charge and close
MicroVersaTrip PM trip unit (M or PM option)
Select the A-Disconnect here only if (1) none of these options were selected in previous steps and
4-wire ground fault is required or (2) none of these options were selected in previous steps and your
WavePro breaker is to be PM ready. PM ready wiring includes inputs for 24V dc auxiliary power,
communications, and 3 phase voltage.
2 Available only on breakers with electrical charge and close option.

8-38 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Low Voltage Power & Insulated Case Circuit Breakers Section 8
WavePro Low Voltage Power Circuit Breakers

WavePro Breaker Power+ and MicroVersaTrip Plus/PM Rating Plugs


Power+ Power+ Power+ MicroVersaTrip
Breaker Frame Current Sensor Rating Plug Rating Plug Rating Plug Rating Plug Plus/PM
Size (Amps) (Amps) (Amps) EntelliGuard TU w/o GF with GF with Defeatable GF Rating Plug
60 GTP0060U0101 N/A N/A N/A TR1B60
80 GTP0080U0101 TR1C80 TR1C80GF TR1C80GFD TR1B80
150 100 GTP0100U0103 TR1C100 TR1C100GF TR1C100GFD TR1B100
125 GTP0125U0103 TR1C125 TR1C125GF TR1C125GFD TR1B125
150 GTP0150U0104 TR1C150 TR1C150GF TR1C150GFD TR1B150
150 GTP0150U0104 N/A N/A N/A TR4B150
200 GTP0200U0204 TR4C200 TR4C200GF TR4C200GFD TR4B200
225 GTP0225U0306 TR4C225 TR4C225GF TR4C225GFD TR4B225
800 4000
250 GTP0250U0407 TR4C250 TR4C250GF TR4C250GFD TR4B250
300 GTP0300U0408 TR4C300 TR4C300GF TR4C300GFD TR4B300
400 GTP0400U0410 TR4C400 TR4C400GF TR4C400GFD TR4B400
300 GTP0300U0408 N/A N/A N/A TR8B300
400 GTP0400U0410 TR8C400 TR8C400GF TR8C400GFD TR8B400
450 GTP0450U0612 N/A N/A N/A TR8B450
800 500 GTP0500U0613 TR8C500 TR8C500GF TR8C500GFD TR8B500
600 GTP0600U0616 TR8C600 TR8C600GF TR8C600GFD TR8B600
700 GTP0700U0816 TR8C700 TR8C700GF TR8C700GFD TR8B700
800 GTP0800U0820 TR8C800 TR8C800GF TR8C800GFD TR8B800
300 GTP0300U0408 N/A N/A N/A TR8B300
400 GTP0400U0410 TR8C400 TR8C400GF TR8C400GFD TR8B400
450 GTP0450U0612 N/A N/A N/A TR8B450
800 500 GTP0500U0613 TR8C500 TR8C500GF TR8C500GFD TR8B500
600 GTP0600U0616 TR8C600 TR8C600GF TR8C600GFD TR8B600
700 GTP0700U0816 TR8C700 TR8C700GF TR8C700GFD TR8B700
1600 800 GTP0800U0820 TR8C800 TR8C800GF TR8C800GFD TR8B800
600 GTP0600U0616 N/A N/A N/A TR16B600
800 GTP0800U0820 TR16C800 TR16C800GF TR16C800GFD TR16B800
1000 GTP1000U1025 TR16C1000 TR16C1000GF TR16C1000GFD TR16B1000
1600
1100 GTP1100U1225 N/A N/A N/A TR16B1100
1200 GTP1200U1232 TR16C1200 TR16C1200GF TR16C1200GFD TR16B1200
1600 GTP1600U1640 TR16C1600 TR16C1600GF TR16C1600GFD TR16B1600
750 GTP0750U0820 N/A N/A N/A TR20B750
800 GTP0800U0820 N/A N/A N/A TR20B800
1000 GTP1000U1025 TR20C1000 TR20C1000GF TR20C1000GFD TR20B1000
2000 2000 1200 GTP1200U1232 TR20C1200 TR20C1200GF TR20C1200GFD TR20B1200
1500 GTP1500U1640 N/A N/A N/A TR20B1500
1600 GTP1600U1640 TR20C1600 TR20C1600GF TR20C1600GFD TR20B1600
2000 GTP2000U2050 TR20C2000 TR20C2000GF TR20C2000GFD TR20B2000
1200 GTP1200U1232 TR32C1200 TR32C1200GF TR32C1200GFD TR32B1200
1600 GTP1600U1640 TR32C1600 TR32C1600GF TR32C1600GFD TR32B1600
3200 3200
2400 GTP2400U2564 TR32C2400 TR32C2400GF TR32C2400GFD TR32B2400
3200 GTP3200U3264 TR32C3200 TR32C3200GF TR32C3200GFD TR32B3200
1600 GTP1600U1640 TR40C1600 TR40C1600GF TR40C1600GFD TR40B1600
2000 GTP2000U2050 TR40C2000 TR40C2000GF TR40C2000GFD TR40B2000
2500 GTP2500U2564 TR40C2500 TR40C2500GF TR40C2500GFD TR40B2500
4000 4000
3000 GTP3000U3064 TR40C3000 TR40C3000GF TR40C3000GFD TR40B3000
3600 GTP3600U4064 N/A N/A N/A TR40B3600
4000 GTP4000U4064 TR40C4000 TR40C4000GF TR40C4000GFD TR40B4000
3200 GTP3200U3264 N/A N/A N/A TR50B3200
5000 5000 4000 GTP4000U4064 N/A N/A N/A TR50B4000
5000 GTP5000U5064 N/A N/A N/A TR50B5000

Rev. 11/13 www.geindustrial.com BuyLog Catalog 8-39


Data subject to change
without notice
Low Voltage Power & Insulated Case Circuit Breakers Section 8
OEM Substructures and Substructure Accessories

Table B-1.
Breaker Substructures
NOTE: Use shallow substructures unless there are other deep substructures
in the line-up.

Frame Size Breaker Type Substructure Type Substructure Product No.

Shallow (29") WPS08SUBSH1


WPS-08
Deep (36") WPS08SUBDP1
Large frame sub-structure
Shallow (29") WPH08SUBSH1
WPH-08 (shown with optional accessories)
800 Deep (36") WPH08SUBDP1
Shallow (29") WPX08SUBSH1
WPX-08
Deep (36") WPX08SUBDP1
WPF-08 Deep (36") WPF08SUBDP1
Shallow (29") WPS16SUBSH1
WPS-16
Deep (36") WPS16SUBDP1
Shallow (29") WPH16SUBSH1
WPH-16
1600 Deep (36") WPH16SUBDP1
Deep (36") WPF16SUBDP1
WPF-16 Deep, with 2500A WPF16SUBDP2
CL Fuses (36")
Shallow (29") WPS20SUBSH1
WPS-20
Deep (36") WPS20SUBDP1
2000
Shallow (29") WPS20SUBSH2
WPS-20 with OFLO
Deep (36") WPS20SUBDP2
WPS-32 Shallow (29") WPS32SUBSH1
WPS-32 with OFLO Shallow (29") WPS32SUBSH2
3200
WPH-32 Shallow (29") WPH32SUBSH1
WPX-32 Shallow (29") WPX32SUBSH1
WPS-40 Shallow (29") WPS40SUBSH1
4000 WPS-40 with OFLO Shallow (29") WPS40SUBSH2
WPX-40 Shallow (29") WPX40SUBSH1
WPS-50 Deep (36") WPS50SUBDP1
5000 WPS-50 with OFLO Deep (36") WPS50SUBDP2
WPX-50 Deep (36") WPX50SUBDP1

Table B-2.
Fuse Rollout Elements and Substructures for Drawout Equipment Substructures
600 Volts AC, 50/60 Hz
NOTE: When used in conjunction with these fuse roll out elements, WavePro Type WPS
drawout circuit breaker elements should be equipped with an open fuse lockout (OFLO)
device, and the WPS breaker substructure should be ordered with a Keylock Mounting
Kit. Key interlock is supplied and mounted by the customer.

Fuse Roll Out Element (FRE)


Only (No Fuses) 1,2 FRE Drawout Substructures 2,3
Substructure
Frame Size Type Product No. Product No.
2000A/3200A Shallow WP32FRE WP32FRSUBSH1
4000A Shallow WP40FRE WP40FRSUBSH1
5000A Deep WP50FRE WP50FRSUBSH1
1 Fuse rollouts accept special Class L fuses 2000-5000 Amps. See WavePro Application Guide
(DET-167) for additional information.
2 UL recognized component.
3 Substructures for fuse rollouts include provision for keylock mounting as standard feature.

8-40 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Low Voltage Power & Insulated Case Circuit Breakers Section 8
OEM Substructures and Substructure Accessories

Table B-3
Breaker Substructures Accessories
Substructure accessories shown assembled are shipped separately for field installation.
Substructure Accessory
Product Number Accessory Product Number
Secondary Disconnect (bracket only) WPSDSFSH1
Secondary Disconnect (one 36-pin block) WPSDSUBM1
CT Hardware Mounting Kit, Metering Type (for 3 CTs) WPCTMTG1
CT Hardware Mounting Kit, Relaying Type (for 3 CTs) WPCTMTG2
WPS08SUBSH1 One-stage Position Switch Kit WPPSMTG1 Secondary disconnect blocks
WPH08SUBSH1
WPX08SUBSH1 Three-stage Position Switch Kit WPPSMTG2
Shutter Kit WPSHMTG1
Padlock Kit Standard on breaker
Keylock Mounting Kit (bracket only) WPSKLMTG1
Door Interlock Kit WPDIMTG1
Secondary Disconnect (bracket only) WPSDSFDP1
Secondary Disconnect (one 36-pin block) WPSDSUBM1
CT Hardware Mounting Kit, Metering Type (for 3 CTs) WPCTMTG1
CT Hardware Mounting Kit, Relaying Type (for 3CTs) WPCTMTG2
WPS08SUBDP1 One-stage Position Switch Kit WPPSMTG3
WPH08SUBDP1
WPX08SUBDP1 Three-stage Position Switch Kit WPPSMTG4
Shutter Kit WPSHMTG2
Padlock Kit Standard on breaker
Keylock Mounting Kit (bracket only) WPSKLMTG1
Door Interlock Kit WPDIMTG1
Secondary Disconnect (bracket only) WPSDSFDP1 Secondary disconnect bracket
Secondary Disconnect (one 36-pin block) WPSDSUBM1 with disconnects installed
CT Hardware Mounting Kit, Metering Type (for 3 CTs) WPCTMTG1
CT Hardware Mounting Kit, Relaying Type (for 3 CTs) WPCTMTG2
One-stage Position Switch Kit WPPSMTG5
WPF08SUBDP1
Three-stage Position Switch Kit WPPSMTG6
Shutter Kit WPSHMTG3
Padlock Kit Standard on breaker
Keylock Mounting Kit (bracket only) WPSKLMTG1
Door Interlock Kit WPDIMTG1

CT mounting hardware kit

Rev. 11/13 www.geindustrial.com BuyLog Catalog 8-41


Data subject to change
without notice
Low Voltage Power & Insulated Case Circuit Breakers Section 8
OEM Substructures and Substructure Accessories

Table B-3 (continued)


Breaker Substructures Accessories (cont.)

Substructure Accessory
Product Number Accessory Product Number
Secondary Disconnect (bracket only) WPSDSFSH1
Secondary Disconnect (one 36-pin block) WPSDSUBM1
CT Hardware Mounting Kit, Metering Type (for 3 CTs) WPCTMTG1
CT Hardware Mounting Kit, Relaying Type (for 3 CTs) WPCTMTG2

WPS16SUBSH1 One-stage Position Switch Kit WPPSMTG1


WPH16SUBSH1 Three-stage Position Switch Kit WPPSMTG2
Shutter Kit WPSHMTG1
Padlock Kit Standard on breaker
Keylock Mounting Kit (bracket only) WPSKLMTG1
Door Interlock Kit WPDIMTG1 Position switch kit
Secondary Disconnect (bracket only) WPSDSFDP1
Secondary Disconnect (one 36-pin block) WPSDSUBM1
CT Hardware Mounting Kit, Metering Type (for 3 CTs) WPCTMTG1
CT Hardware Mounting Kit, Relaying Type (for 3 CTs) WPCTMTG2

WPS16SUBDP1 One-stage Position Switch Kit WPPSMTG3


WPH16SUBDP1 Three-stage Position Switch Kit WPPSMTG4
Shutter Kit WPSHMTG2
Padlock Kit Standard on breaker
Keylock Mounting Kit (bracket only) WPSKLMTG1
Door Interlock Kit WPDIMTG1
Secondary Disconnect (bracket only) WPSDSFDP1
Secondary Disconnect (one 36-pin block) WPSDSUBM1
CT Hardware Mounting Kit, Metering Type (for 3 CTs) WPCTMTG1
CT Hardware Mounting Kit, Relaying Type (for 3 CTs) WPCTMTG2

WPF16SUBDP1 One-stage Position Switch Kit WPPSMTG5


(Fuse <2500A) Three-stage Position Switch Kit WPPSMTG6
Shutter Kit WPSHMTG3
Shutter kit as installed on
substructure
Padlock Kit Standard on breaker
Keylock Mounting Kit (bracket only) WPSKLMTG1
Door Interlock Kit WPDIMTG1
Secondary Disconnect (bracket only) WPSDSFDP1
Secondary Disconnect (one 36-pin block) WPSDSUBM1
CT Hardware Mounting Kit, Metering Type (for 3 CTs) WPCTMTG1
CT Hardware Mounting Kit, Relaying Type (for 3 CTs) WPCTMTG2

WPF16SUBDP2 One-stage Position Switch Kit WPPSMTG7


(Fuse = 2500A) Three-stage Position Switch Kit WPPSMTG8
Shutter Kit Contact factory
Padlock Kit Standard on breaker
Keylock Mounting Kit (bracket only) WPSKLMTG1
Door Interlock Kit WPDIMTG1

8-42 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Low Voltage Power & Insulated Case Circuit Breakers Section 8
OEM Substructures and Substructure Accessories

Table B-3. (continued)


Breaker Substructures Accessories (cont.)
Substructure Accessory
Product Number Accessory Product Number
Secondary Disconnect (bracket only) WPSDSFSH1
Secondary Disconnect (one 36-pin block) WPSDSUBM1
CT Hardware Mounting Kit, Metering Type (for 3 CTs) WPCTMTG1
CT Hardware Mounting Kit, Relaying Type (for 3 CTs) WPCTMTG2

WPS20SUBSH1 One-stage Position Switch Kit WPPSMTG1


WPS20SUBSH2 Three-stage Position Switch Kit WPPSMTG2
Shutter Kit WPSHMTG1
Padlock Kit Standard on breaker
Keylock Mounting Kit (bracket only) WPSKLMTG1
Door Interlock Kit WPDIMTG1
Secondary Disconnect (bracket only) WPSDSFDP1 Padlock kit (standard on small
Secondary Disconnect (one 36-pin block) WPSDSUBM1 frame breakers, optional on
CT Hardware Mounting Kit, Metering Type (for 3 CTs) WPCTM1G1 large frame breakers)
CT Hardware Mounting Kit, Relaying Type (for 3 CTs) WPCTMTG2

WPS20SUBDP1 One-stage Position Switch Kit WPPSMTG3


WPS20SUBDP2 Three-stage Position Switch Kit WPPSMTG4
Shutter Kit WPSHMTG2
Padlock Kit Standard on breaker
Keylock Mounting Kit (bracket only) WPSKLMTG1
Door Interlock Kit WPDIMTG1
Secondary Disconnect (bracket only) WPSDLFSH1
Secondary Disconnect (one 36-pin block) WPSDSUBM2
CT Hardware Mounting Kit, Metering Type (for 3 CTs) WPCTMTG1
CT Hardware Mounting Kit, Relaying Type (for 3 CTs) WPCTMTG2
WPS32SUBSH1
WPS32SUBSH2 One-stage Position Switch Kit WPPSMTG9
WPH32SUBSH1 Three-stage Position Switch Kit WPPSMTG10
WPX32SUBSH1
Shutter Kit WPSHMTG4
Padlock Kit WPPKMTG1
Keylock Mounting Kit (bracket only) WPSKLMTG2 Keylock mounting kit bracket
Door Interlock Kit WPDIMTG2
Secondary Disconnect (bracket only) WPSDLFSH1
Secondary Disconnect (one 36-pin block) WPSDSUBM2
CT Hardware Mounting Kit, Metering Type (for 3 CTs) WPCTMTG1
CT Hardware Mounting Kit, Relaying Type (for 3 CTs) WPCTMTG2
WPS40SUBSH1 One-stage Position Switch Kit WPPSMTG9
WPS40SUBSH2
WPX40SUBSH1 Three-stage Position Switch Kit WPPSMTG10
Shutter Kit WPSHMTG4
Padlock Kit WPPKMTG1
Keylock Mounting Kit (bracket only) WPSKLMTG2
Door Interlock Kit WPDIMTG2
Secondary Disconnect (bracket only) WPSDLFDP1
Secondary Disconnect (one 36-pin block) WPSDSUBM2
CT Hardware Mounting Kit, Metering Type (for 3 CTs) WPCTMTG3
CT Hardware Mounting Kit, Relaying Type (for 3 CTs) Contact factory
WPS50SUBDP1 One-stage Position Switch Kit WPPSMTG9 Door interlock kit
WPS50SUBDP2
WPX50SUBDP1 Three-stage Position Switch Kit WPPSMTG10
Shutter Kit WPSHMTG5
Padlock Kit WPPKMTG2
Keylock Mounting Kit (bracket only) WPSKLMTG3
Door Interlock Kit WPDIMTG3

Continued on next page

Rev. 11/13 www.geindustrial.com BuyLog Catalog 8-43


Data subject to change
without notice
Low Voltage Power & Insulated Case Circuit Breakers Section 8
OEM Substructures and Substructure Accessories
Table B-4.
Fuse Rollout Substructure Accessories
Substructure Accessory
Product Number Accessory Product No.
Secondary Disconnect (bracket only) WPSDLFSH1
Secondary Disconnect (one 36-pin block) WPSDSUBM2
Metering CT Hardware Mounting Kit (for three CTs) WPCTMTG1
Relaying CT Hardware Mounting Kit (for three CTs) WPCTMTG2

WP32FRSUBSH1 One-stage Position Switch Kit WPPSMTG9


WP40FRSUBSH1 Three-stage Position Switch Kit WPPSMTG10
Shutter Kit WPSHMTG4
Padlock Kit WPPKMTG1
Keylock Mounting Kit (bracket only) Part of substructure
Door Interlock Kit WPDIMTG2
Secondary Disconnect (bracket only) WPSDLFDP1
Secondary Disconnect (one 36-pin block) WPSDSUBM2
Metering CT Hardware Mounting Kit (for three CTs) WPCTMTG3
Relaying CT Hardware Mounting Kit (for three CTs) Not available
One-stage Position Switch Kit WPPSMTG9
WP50FRSUBSH1
Three-stage Position Switch Kit WPPSMTG10
Shutter Kit WPSHMTG5
Padlock Kit WPPKMTG2
Keylock Mounting Kit (bracket only) Part of substructure
Door Interlock Kit WPDIMTG3

Table B-5.
Neutral Current Transformers (required with 4-wire ground fault).
Circuit Breaker Sensor Neutral Sensor
Frame (Amps) Amps Rating Rating (Amps) Product Number
150 100-300 TSVG303B
800
400, 800 300-800 TSVG508B
800 300-800 TSVG508B
1600
1600 600-1600 TSVG516B
2000 2000 800-2000 TSVG620B
3200 3200 1200-3200 TSVG832B
4000 4000 1600-4000 TSVG940B
Neutral Current Transformer
5000 5000 5000 TSVG950B

Table B-6.
Static Time Delays for Undervoltage Option
Voltage Static Time Delay Product No. 1
125Vdc TAKYUVT1
250Vdc TAKYUVT2
208 Vac (50/60 Hz) TAKYUVT5
240 Vac (50/60 Hz) TAKYUVT4
1
Must be ordered in conjunction with Undervoltage with Time Delay option in Step 6 on page 8-37.

Table B-7.
Miscellaneous Accessories
Static Time Delay
Accessory Product Number
Breaker Racking HandleStd 30" Long - Non Swivel 0324B4721G001
Breaker Racking Handle64" Long - Non Swivel 0324B4721G002
Breaker Racking Handle30" Long - Swivel Socket 0324B4724G001
Maintenance Closing Handle 568B386G1
Small Frame Lifting Assembly, WP08, 16, 20 0324B4551G001
Large Frame Lifting Assembly, WP32, 40 0247B8961G001
Extra Large Frame Lifting Assembly, WP50 0247B8961G003
Fuse Rollout Out Element Lifting Assembly, 3200A & 4000A 0247B8961G004
Fuse Rollout Element Lifting Assembly, 5000A 0247B8961G005
WavePro Breaker Maintenance Video (Approx. 40 minutes, VHS format) 2 DEV-042
2 Order only from Burlington OEM marketing.

8-44 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Low Voltage Power & Insulated Case Circuit Breakers Section 8
OEM Substructures and Substructure Accessories
Table B-8.
POWER LEADER Power Supply
Power supply for furnishing 24Vdc control power for EntelliGuard TU, MicroVersaTrip Plus and PM trips units.
System Requirements
Description Product Number (Not included with power supply)
1.5A power supply. PLPS4G01 Input power, 100VA
Maximum wire length from power supply (85-265 Vac or 100-370 Vdc)
to trip device is 100 feet. A maximum of 45 trip
units may be powered from a single power supply.

Table B-9.
POWER LEADER Voltage Conditioner
Conditions and scales 120Vac to 1.76Vac for use by the trip unit for voltage sensing. Provides transient protection. Requires isolation
PTs with 120 volt secondary. Supports up to 15 trip units at a maximum distance of 20 feet. Required for PM trip units only.
System Requirements
Description Product Number (Not included with voltage conditioners)
Supplies isolated bus voltage signal PLVC1G01 One set of 3 voltage conditioners required
to EntelliGuard TU and MicroVersaTrip PM trip units. for each sensing location. PTs also required.

Table B-10.
The hand-held Portable Battery Pack provides an independent power source for EntelliGuard TU, microEntelliGuard, MicroVersaTrip
Plus and MicroVersaTrip PM trip units as an alternative to a test set. The battery pack is used to power up the trip unit to set or adjust
trip set points when the breaker is on the bench or otherwise not powered up. For microEntelliGuard trip units, the battery pack
connects to the trip unit through the 15-pin connector. A battery pack adapter cable is required. For MicroVersaTrip Plus and
MicroVersaTrip PM trip units, the battery pack connects to the trip unit through the rating plug test jack. The battery pack requires
three standard 9 Vdc alkaline batteries (not included).
Description Product Number
MicroVersaTrip Plus and PM Portable Power Pack TVPBP
EntelliGuard TU, microEntelliGuard Battery Pack Adapter Cable TVPBPACC

Table B-11.
MicroVersaTrip Rating Plug Removal Tool

Description Product Number


MicroVersaTrip Rating Plug Removal Tool TRTOOL

Table B-12.
Portable Test Set
This portable, battery powered test kit provides self-tests and functional trip/no trip tests. It also provides defeat of the ground fault
function and be used in conjunction with high current test equipment. Interface is via a plug on the front of the trip units, and tests
can be conducted with the breaker in service. Test sets use either 120Vac power source or internal batteries (not included).

Description Trip Unit Type Product Number


MicroVersaTrip only TVRMS2
Portable Test Set
EntelliGuard TU and microEntelliGuard GTUTK20

Portable Test Set - MicroVersaTrip Portable Test Set - EntelliGuard TU and microEntelliGuard

Rev. 11/13 www.geindustrial.com BuyLog Catalog 8-45


Data subject to change
without notice
Low Voltage Power & Insulated Case Circuit Breakers Section 8
OEM Substructures and Substructure Accessories

Table B-13.
Metering and Relaying Current Transformers for 800-5000A Substructures, 600 Vac, 50/60 Hz
Breaker Frame Size Ampere Ratio ():5 Metering Product Number Metering & Relaying Product Number
100 75C149640P001 75C149640P025
150 75C149640P002 75C149640P026
200 75C149640P003 75C149640P027
250 75C149640P004 75C149640P028
300 75C149640P005 75C149640P029
400 75C149640P006 75C149640P030
500 75C149640P007 75C149640P031
800A
1600A 600 75C149640P008 75C149640P032
2000A
800 75C149640P010 75C149640P034
1000 75C149640P011 75C149640P035
1200 75C149640P012 75C149640P036
1500 75C149640P013 75C149640P037
1600 75C149640P014 75C149640P038
2000 75C149640P015 75C149640P039
2500 75C149640P016 75C149640P040
2000 75C149640P020 75C149640P044
2500 75C149640P021 75C149640P045
3200A 3000 75C149640P022 75C149640P046
4000A
3200 75C149640P023 75C149640P047
4000 75C149640P024 75C149640P048
5000A 5000 75C149640P049 Consult Factory

8-46 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Low Voltage Power & Insulated Case Circuit Breakers Section 8
OEM Substructures and Substructure Accessories

Switchgear Module and Trolley for use with Gerapid


High-Speed DC Circuit Breakers
GE offers UL recognized OEM switchgear modules and drawout
trolleys for use with Gerapid High-Speed DC circuit breakers.
Modules come factory assembled, and can be used to form
lineups of DC switchgear. The OEM provides required bussing,
wiring, controls and covers necessary to complete the switchgear.
The Trolley is designed to accept Gerapid DC breakers, interface
with the OEM Module and includes pre-wired secondary control
harness and required interlocking.

Key Module Features include:


NEMA 1, zinc-plated bolted steel frame construction
26 W x 87 H x 59 D
Optional 71 depth for extra bus and cable space
Rated for 800VDC, 200kA peak withstand
Copper stationary primary stabs available for
2500A thru 6000A
Side-covers and doors painted ANSI Grey
Insulated safety shutters with padlock provisions
Secondary control compartment with hinged, padlockable door
21.5 H x 22.8 W x 8.6 D
Breaker secondary control wiring harness and plug included OEM Switchgear Modules
Designed to meet ANSI C37.20.1 requirements
UL Recognized

Key Trolley Features include:


Designed for use with Gerapid OEM Modules
Complete drawout trolley for Gerapid UL Listed 2508 4008,
5008 and 6008 breakers
Breaker secondary control wiring harness & socket included
Breaker compartment door is hinged and fixed to trolley
structure (dead front)
Trolley front cover (door) has inspection window to view breaker
position indicator and operations counter
Trolley is grounded in all positions
Designed to meet ANSI C37.20.1 and C37.14 interlocking and Gerapid
other requirements High-Speed
Standard manual racking drive Circuit Breaker
Optional motor drive racking, 230VAC/60HZ
UL Recognized

OEM Benefits
Simplified OEM Modules (substructures)
Complete drawout DC breaker solution
Trolleys and Modules are UL recognized.
Outlines available in PDF and as AutoCAD templates for OEMs Drawout Trolley
All breaker controls prewired to secondary control disconnect
ANSI C37.20.1 and C37.14 required interlocking included
Accessories available, including various covers
and hardware kits

Rev. 11/13 www.geindustrial.com BuyLog Catalog 8-47


Data subject to change
without notice
Low Voltage Power & Insulated Case Circuit Breakers Section 8
OEM Substructures and Substructure Accessories

Substructures

Description Product Number


Gerapid OEM Module-4kA-1500mm 700689
Gerapid OEM Module-6kA-1500mm 700690
Gerapid OEM Module-4kA-1800mm 700691
Gerapid OEM Module-6kA-1800mm 700692

Breaker Trolley
Description Product Number
Gerapid OEM Trolley-motor driven 700693
Gerapid OEM Trolley-manual drive 700694

Accessories
Description Product Number
Racking Handle 700695
Rear Side Cover 1500mm Depth Unit 700696
Rear Side Cover 1800mm Depth Unit 700697
Control Wireway Connector 700698
Control Wireway Cover 700699
Section Bolting Hardware Kit 289158
Cover Attachment Harware kit 289160
Door Hinges Kit 289709

To configure Gerapid OEM Modules and DC Circuit Breakers, visit our web\ wizard configuration tool at:
http://www.geindustrial.com/cwc/Dispatcher?REQUEST=PRODUCTS&id=gerapid&lang=en_US

8-48 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Low Voltage Power & Insulated Case Circuit Breakers Section 8
Trip Units
EntelliGuard TU Trip Unit Features

EntelliGuard TU Trip Unit


New capabilities in the EntelliGuard TU Trip Unit provide ultimate
system reliability and selectivity without sacrificing circuit protec-
tion. This superior addition enhances the circuit breakers with a
Waveform Recognition Instantaneous Algorithm that
eliminates costly downtime due to nuisance tripping. It enables
harmonic analysis four cycles prior and after an event, and
discerns whether a downstream breaker/fuse is clearing the fault.
The unit also includes Instantaneous Zone Selective Interlocking
(I-ZSI) (can be used as a feeder and downstream device with a
power circuit breaker upstream) which delivers simultaneous and
independent ZSI of Short Time, Ground Fault and Instantaneous
protection, providing the ability to overlap the Instantaneous on
the Main and Feeder breakers. Together, these innovative abilities
achieve HRC2 with currents as high as 100kA with simultaneous
flash protection and selectivity.
The EntelliGuard TU Trip Unit offers optimum circuit safety
and arc flash protection with the Reduced Energy Let-Through
function, providing a faster instantaneous trip that may be
used if faster and more sensitive protection is required
temporarily. It is commonly referred to as an Arc Flash Switch
or Maintenance Switch.
The new and improved trip unit design delivers selectivity tools Maintenance and Diagnostics
not previously available in GE circuit breakers: Universal trip plug fits any trip unit.
Flexible serial communication via Modbus RTU
Integrates directly into GEs EnerVista Power
Exclusive EntelliGuard TU Trip Unit Features
Management System.
Designed for Flexibility Large backlit LCD with detailed, easy-to-see descriptions.
A wide range of continuous adjustment Long Time delays Health status via breaker LED indicating normal operation,
ensure the circuit breaker can be exactly adjusted in to your errors, pickup, and trips while providing non-volatile memory
selectivity and protection needs. with a continuous self-testing microprocessor
Multiple Short Time diagonal bands tune your protection to Lithium battery to eliminate need for external power for
exactly where it needs to be. set-up and review
Flexible time current settings and curves -Standard Long Time 10 event Log with Date/Time Stamp: Stores the last 10 events.
characteristics exactly mimic the curve of a thermal magnetic Date/Time with 24Vdc Power.
circuit breaker. Thermal Memory
Flexible Time Current Curves: 44 Long Time Shapes I2T and WaveForm Capture: 40 Samples/Cycle, 4 cycles prior and 4
I4T (fuse), 3 Short Time I2T slopes, Short Time adjustable in 55 cycles post event in COMTrade format.
ms increments, a Selective Ground Fault curve Free set-up software
Instantaneous Protection
Instantaneous pick-up is adjustable up to 15 times the plug To learn more about EntelliGuard TU Trip Unit
rating on frames 800-2000A, 13 times on 3000A frames and features see brochure DEA-461C.
up to 9 times on 4000A frames.
A separately adjustable fast instantaneous trip- useful for
when the circuit must provide the best possible protection
and arc flash performance while sustaining normal load.
An override instantaneous - provides fast tripping for the
largest bolted fault currents to minimize potential damage.
Up to 17 Short Time bands allow you to set your circuit break-
er to sustain load requirements without slowing protection.
Ground Fault Alarm via I/O or Modbus Communications
Ground fault protection with faster time bands, multiple
slopes and the ability to coordinate a 1200A ground fault
with an 800A circuit breaker a ratio four times better than in
previous generation trip units

Rev. 11/13 www.geindustrial.com BuyLog Catalog 8-49


Data subject to change
without notice
Low Voltage Power & Insulated Case Circuit Breakers Section 8
Trip Units
Power+ Trip Unit Features

Power+ Trip Unit Systems Trip Target Module (Optional)


The Power+ trip unit system for insulated case circuit breakers View Button: Press the VIEW button to check the trip unit status.
consist of the trip unit, the trip actuator, current sensors and rat- Reset Button: Press the RESET button to clear any target that is set.
ing plugs. The term trip unit system applies to the combination
Battery check: Target modules use two standard, 3V, 16mm x
of these four components which form the solid-state
1.6mm, lithium batteries for viewing target information. Battery life
circuit breaker tripping system.
depends upon use, but may be estimated at one year. When the
Power+ trip units provide a complete range of standard and batteries are energized, depressing the VIEW button will illuminate
optional overcurrent and ground-fault protective functions. either a set target LED, i.e., LT or the BAT LED. Once target indicators
True RMS Sensing are cleared, battery status is indicated by the BAT LED. Replacement
The Power+ trip unit continues to batteries include Panasonic CR1616, Eveready E-CR1616BP, or
use GEs proven technique of Duracell DL1616B, which may be purchased commercially.
measuring true rms currents of Long-time pickup: The long-time pickup indicator moves through
both sinusoidal and harmonically two transitions. As the current in any phase reaches 95% of its
distorted waveforms. The frequent setpoint; the LTPU LED begins to flash. As current increases,
sampling (48 times per cycle per flashing frequency increases, until 100% of the pickup point is
phase) allows precise calculations reached. At that moment, the LTPU LED stays on continuously until
of true rms current. The sampling the long-time delay times out. Once the breaker has tripped on
rate allows waveform measure- long-time, the OVL target will be stored in memory. To view the trip,
ments up to the 11th harmonic. press the VIEW button. To clear the target, press the RESET button.
GEs true rms sensing avoids Short-time and instantaneous trips: Short-time and instantaneous
potential underprotection or over- trips share the same trip target. The LTPU LED is not illuminated,
protection problems associated since the time intervals between pickup and tripping are too short
with peak-sensing tripping systems. for either function. Once the breaker has tripped on short-time or
instantaneous, the short target will be stored in memory. To view the
trip, press the VIEW button. To clear the target, press the RESET button.
Accessory Integration
Ground fault trip (Target02 only): The trip target for a ground
Four accessories are integrated through the Power+ trip unit.
fault trip is the GF LED. To view the trip, press the view button. To
Drop-in shunt trip (with or without lockout), bell alarms (with or
clear the target, press the RESET button.
without lockout) and the undervoltage release modules fit into
keyed pockets. They operate through the trip units, and not Health monitor: Trip unit health status okay is illustrated by
through any external mechanisms. All accessory wiring is pre- slow blinking of the LTPU LED. It may be seen by depressing and
wired to secondary terminals, and no user wiring is necessary. holding the VIEW button. Sufficient power must be supplied to the
When activated, the shunt trip (with or without lockout) and trip unit via external test kit, power pack, or current transformers
undervoltage release modules send a signal to the trip unit to for the health monitor to be operational.
energize the trip actuator and open the breaker.
Standard and Optional Protective Functions
Standard and optional protective functions are available for
Power+ trip units. The breaker settings are programmed in multi-
ples of X (rating plug ampere values), S (current sensor ampere
rating values), and C (the long-time setting in amperesmultiply
long-time setting by rating plug ampere rating).

Standard
Adjustable Long-Time (L) Pickup, 0.5 - 1.0X, with four delay bands.
Adjustable Instantaneous (I) Pickup, 1.5 - 15X.1

Options
Overload, Short Circuit, and Short-Time local trip indicators with
overload pickup warning and health monitor.
Adjustable Short-Time (S) Pickup, 1.5 - 9.0C, and delay (3 bands)
with I2t ON/OFF selection.
Adjustable Ground Fault (G) Pickup, 0.2 - 0.6S, and delay1
Power+ Trip Target Module (3 bands) with I2t ON/OFF selection and trip indicator.
Upgradeable Ground Fault function with use of appropriate
ground fault rating plug.
1Limited by breaker frame size above 2000A.

8-50 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Low Voltage Power & Insulated Case Circuit Breakers Section 8
Trip Units
Enhanced MicroVersaTrip Trip Unit Features

Enhanced MicroVersaTrip Trip Units


Enhanced MicroVersaTrip Plus and MicroVersaTrip PM trip units
give you two new ways to monitor and control the circuit breaker
with unprecedented ease. Through the simple keypad, the trip
unit lets you program and display a variety of functions including
tripping characteristics, remote communications, status informa-
tion and protective relaying, and allows integration with GE
POWER LEADER Power Management Systems. The trip unit dis-

F O I L D P L W H TA
S
play also allows viewing of many standard metering parameters

R AB MV E TE EN TU
as well as pickup alarms, trip target indications and fault

6 9 AV R D E E Y S R I P
status information.
Enhanced MicroVersaTrip Plus and MicroVersaTrip PM trip
units continue to use GEs proven technique of measuring true

8- E TU S E T C T
rms currents (and voltages for MicroVersaTrip PM trip units) of
both sinusoidal and harmonically distorted waveforms. The fre-

E R C I L A A
quent sampling (64 times per cycle) allows precise calculations of Enhanced MicroVersaTrip Plus and MicroVersaTrip PM Trip

E T E. T .
LS EE P
Units have been specifically designed to integrate with the
G S A FA R Y S O E G R S

D L T D
true rms current. The sampling rate allows waveform measure-
ments up to the 31st harmonic to achieve accuracies of 99%. extensive capabilities offered by circuit breakers.

AI S RI
GEs true rms sensing avoids potential underprotection or over-
PA I T U O B L V E
protection problems associated with peak-sensing tripping systems.
The enhanced trip unit design includes a wide range of functions
and adds many new features:
N N T O N O
U A EN BE S I CR

.
UL Listed Field-Interchangeable Features exclusive to MicroVersaTrip PM Trip Units
Non-volatile trip targets display/Cold setup capability Communications
Replaceable long-life batteries provide trip target indications All information can be viewed on the LCD display or
I
RE N L I M

and cold setup capabilitywithout the need for external communicated over a POWER LEADER Power
power or a battery pack. Management System network.
E
Trip operations counter Demand/peak demand
:

The number of long-time, short-time, instantaneous and The trip unit can display a rolling average of power demand
W U E
T

ground fault trips are individually counted and displayed. and peak power demand at user-selected intervals from 5 to
I P OT

Trip information 60 minutes.


A
N

On overcurrent faults, the trip unit displays fault pickup, the Local and remote metering
type of fault, the magnitude of the fault current and the Amps, volts, frequency
TR N

phase the fault occurred on. Real power, total power


Display indicates when a shunt trip or undervoltage release Accumulated energy
trip has opened the breaker. Protective relays include:
L

New display Current and voltage unbalance


I

Ergonomic, 5-button keypad Overvoltage


V

New targets with international symbols Undervoltage


High-resolution LCD display for local 3-phase ammetering Power reversal
New status and setup displays for greater ease of use Power reversal direction setup
I

True rms sensing for accurate response to high harmonic


M

content waveforms for Long-Time, Short-Time, and Ground


Fault protection.
50/60 Hz operation.
Interchangeable, UL Listed trip units and rating plugs with test
set jack for TVRMS2 test set.
EMI immunity per ANSI C37.90.

Rev. 11/13 www.geindustrial.com BuyLog Catalog 8-51


Data subject to change
without notice
Low Voltage Power & Insulated Case Circuit Breakers Section 8
Trip Units
Trip Unit Characteristics

EntelliGuard TU Trip Unit Characteristics


Long Time Short Time
Frame Max. Sensor Rating Current Setting (C) (Pick-Up) Delay (Seconds)1 Pick-up (Multiple
Envelope Size Ampere Rating (Amperes) (S) Multiple of Rating Plug Amperes (X) Fuse Type (F-Bands) Thermal Type (C-Bands) of Current Settings) (C) Delay (Seconds)
0.025 0.20
800 800 200, 400, 800 0.025 0.60
0.025 1.21
0.032 1.61 I2T in
0.044 2.41 Minimum - 0.046
1600 1600 800, 1000, 1600
0.059 3.21 Intermediate - 0.186
0.078 4.02 Maximum - 0.4181
0.10 4.82
0.5 thru 1.0 in 0.13 5.62 1.5 thru 9.0 in
2000 2000 2000
Increments of 0.05 0.17 6.43 Increments of 0.5
0.22 7.23
0.27 8.04
2500 1000, 2000, 2500 0.35 9.64
3000 0.44 11.20 I2T out
0.55 12.90 0.025, 0.033, 0.042,
3000 3000
0.69 14.50 0.058, 0.092, 0.117,
0.87 16.10 0.158, 0.183, 0.217,
4000 4000 4000 1.10 17.70 0.350, 0.4172
19.30

Trip Unit Characteristics (continued)


Adjustable Instantaneous Adjustable Instantaneous Ground Fault3
Pick-Up without ST (Multiple Pick-Up with ST (Multiple RELT RELT Pick-Up (Multiple of Delay with I2T Slope Fixed
Envelope Size of Rating Plug Amperes) (X) of Rating Plug Amperes) (X) without ST with ST Sensor Ampere Rating) in Seconds Bands Delay
0.058
2.0 thru 10.0 in 2.0 thru 15.0 in 1.5 thru 10.0 in 1.5 thru 15.0 in 0.20 thru 0.60 in 0.092
800
0.5 increments 0.5 increments 0.5 increments 0.5 increments increments of 0.01 0.117
2.0 thru 10.0 in 2.0 thru 15.0 in 1.5 thru 10.0 in 1.5 thru 15.0 in 0.20 thru 0.60 in I2T - .385 0.158
1600 .44 at 200% I2T - .385
0.5 increments 0.5 increments 0.5 increments 0.5 increments increments of 0.01 0.183
of pick-up 0.217
2.0 thru 10.0 in 2.0 thru 15.0 in 1.5 thru 10.0 in 1.5 thru 15.0 in 0.20 thru 0.60 in I4T - .179
2000 at lower I4T - .179
0.5 increments 0.5 increments 0.5 increments 0.5 increments increments of 0.01 0.35
limit of 0.417
2.0 thru 10.0 in 2.0 thru 13.0 in 1.5 thru 10.0 in 1.5 thru 13.0 in 0.20 thru 0.37 in SGF - .553
3000 band SGF - .553
0.5 increments 0.5 increments 0.5 increments 0.5 increments increments of 0.01 0.517
2.0 thru 9.0 in 2.0 thru 9.0 in 1.5 thru 9.0 in 1.5 thru 9.0 in 0.20 thru 0.30 in 0.617
4000
0.5 increments 0.5 increments 0.5 increments 0.5 increments increments of 0.01 0.717
0.817
0.917
1Time delay shown at 600% of current setting at lower limit of band.
2Time delay shown at lower limit of each band. All pick-up tolerances are 10%.
3Time delay shown at lower limit of each band. Ground fault pick-up not to exceed 1200 amperes

Additional Features and Characteristics of the EntelliGuard TU Trip Unit


Product Number Digit

Function Description 1 2 3 4 5 6 7 8 9 X A4 B4 C4 D4 E4
Metering
Communications Modbus Communications Bus Link
Amperes (A, kA)2 Selectable Phase Current 2.5%
Voltage (V) L-L or L-N Volts 1.5%
Energy (kWh, Mwh, GWh) Total Energy Usage on Brkr 4%
Real Power (kW/MW) L-L or L-N Power 4%
Total Power (kVA/MVA) L-L or L-N Power 4%
Frequency (Hz) Circuit Frequency 1Hz
Demand & Peak Demand (kW)
Relaying
Adjustable pickup, 50-90%
Under Voltage Trip
Adjustable delay, 1-15 seconds OFF
Adjustable pickup, 110-150%
Over Voltage Trip
Adjustable delay, 1-15 seconds OFF
Adjustable pickup, 10-50%
Voltage Unbalance
Adjustable delay, 1-15 seconds OFF
Adjustable pickup, 10-990kW
Current Unbalance Adjustable delay, 1-15 seconds Off
Power Reversal Direction
Data Acquisition - Waveform Capture
RELT
4Used when Ground Fault Alarm is needed via the output contact

8-52 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Low Voltage Power & Insulated Case Circuit Breakers Section 8
Trip Units
Trip Unit Characteristics (continued)

Additional Features and Characteristics of the EntelliGuard TU Trip Unit


Product No. Digits Zone Selective Interlocking Circuit Breaker
Z ZSI, Short time and GF; user selectable
T Z + IOC ZSI; user selectable 1
X NONE SELECTED
1Instantaneous out only

Power+ Trip Unit Characteristics


Long-Time Short-Time
Envelope Frame Max. Sensor Rating Current Setting (C) (Pick-Up) Pick-up (Multiple
Size Ampere Rating (Amperes) (S) Multiple of Rating Plug Amperes (X) Delay2 (Seconds 4 Bands) of Current Setting) (C) Delay (Seconds 3 Bands)
800 200, 400, 800
I2T in2
2000 1600 800, 1000, 1600 .10, .21, .35
0.5, 0.6, 0.7, 2.4, 4.9, 9.8, 20 1.5, 2.0, 2.5, 3.0,
2000 2000 0.8, 0.9, 0.95 and 1.0 4.0, 5.0, 7.0, and 9.0
3000 2500, 3000 1000, 2000, 2500, 3000 I2T out 3
.10, .21, .35
4000 4000 4000

Power+ Trip Unit Characteristics (continued)


Ground Fault
Adjustable Instantaneous Pick-Up without ST Adjustable Instantaneous Pick-Up with ST Pick-Up (Multiple of
Envelope Size (Multiple of Rating Plug Amperes) (X) (Multiple of Rating Plug Amperes) (X) Sensor Ampere Rating) Delay4 (Seconds 3 Bands)
1.5 thru 10.0 1.5 thru 15.0 0.20 thru 0.60
I 2 T in 5
2000 1.5 thru 10.0 1.5 thru 15.0 0.20 thru 0.60 .10, .21, .35
1.5 thru 10.0 1.5 thru 15.0 0.20 thru 0.60
3000 1.5 thru 10.0 1.5 thru 13.0 0.20 thru 0.37 I 2 T out 3
.10, .21, .35
4000 1.5 thru 9.0 1.5 thru 9.0 0.20 thru 0.30

Enhanced MicroVersaTrip Plus and PM Trip Unit Characteristics


Long-Time Short-Time
Frame Max. Sensor Rating Current Setting (C) (Pick-Up) Pick-up (Multiple of
Envelope Size Ampere Rating (Amperes) (S) Multiple of Rating Plug Amperes (X) Delay3 (Seconds) Current Setting) (C) Delay (Seconds)
800 800 200, 400, 800
1600 1600 800, 1000, 1600 I 2 T in2
0.40
2000 2000 2000 0.5 thru 1.0 in 1.5 thru 9.0 in
increments of 0.05 2.4, 4.9, 9.8, 20 increments of 0.5
2500 1000, 2000, 2500
3000 I 2 T out 3
3000 3000
.10, .21, .35
4000 4000 4000

Trip Unit Characteristics (continued)


Ground Fault
Adjustable Instantaneous Adjustable Instantaneous High Range Instantaneous
Pick-Up without ST (Multiple Pick-Up with ST (Multiple (Multiple of Frame Pick-Up (Multiple Delay With l2T Delay4 With l2T
Envelope Size of Rating Plug Amperes) (X) of Rating Plug Amperes) (X) Short-Time Rating) (H) of Sensor Ampere Rating) In Seconds Out Seconds

800 1.5 thru 10.0 in 1.5 thru 15.0 in 0.20 thru 0.60 in
0.5 increments 0.5 increments increments of 0.01

1600 1.5 thru 10.0 in 1.5 thru 15.0 in 0.20 thru 0.60 in
0.5 increments 0.5 increments increments of 0.01
.44 at 200% of
2000 1.5 thru 10.0 in 1.5 thru 15.0 in 1.0 0.20 thru 0.60 in .10, .21, .35
pick-up at lower
0.5 increments 0.5 increments increments of 0.01
limit of band
3000 1.5 thru 10.0 in 1.5 thru 13.0 in 0.20 thru 0.37 in
0.5 increments 0.5 increments increments of 0.01

4000 1.5 thru 9.0 in 1.5 thru 9.0 in 0.20 thru 0.30 in
0.5 increments 0.5 increments increments of 0.01

2 Time delay shown at 600% of current setting at lower limit of band. X = Rating plug amps
3 Time delay shown at lower limit of each band. All pick-up tolerances are 10%. S = Sensor amp rating
4 Time delay shown at lower limit of each band. Ground fault pick-up not to exceed 1200 amperes. C = Long-time current setting (pick-up)
5 Time delay shown at 200% of pick-up at lower limit of band. H = Short-Time Rating

Rev. 11/13 www.geindustrial.com BuyLog Catalog 8-53


Data subject to change
without notice
Low Voltage Power & Insulated Case Circuit Breakers Section 8
Trip Units
Trip Unit Characteristics (continued)

Additional Features and Characteristics Exclusive to the Enhanced MicroVersaTrip PM Trip Unit1
Trip Unit Suffix
Function Description M (Metering) P (Relaying) PM (Metering & Relaying)

Communications POWER LEADER Communications Bus Link STD STD STD


Amperes (A, kA) 2 Selectable Phase Current 2.5% STD STD STD
Voltage (V) L-L or L-N Volts 1.5%
Energy (kWh, MWh, GWh) Total Energy Usage on Brkr 4%
Real Power (kW/MW) L-L or L-N Power 4%
Total Power (kVA/MVA) L-L or L-N Power 4%
Frequency (Hz) Circuit Frequency 1Hz
Demand & Peak Demand (kW)
Adjustable pickup 50-90%
Under Voltage Trip
Adjustable delay, 1-15 seconds OFF
Adjustable pickup, 110-150%
Over Voltage Trip
Adjustable delay, 1-15 seconds OFF
Adjustable pickup, 10-50%
Voltage Unbalance Adjustable delay, 1-15 seconds OFF

Adjustable pickup, 10-50%


Current Unbalance
Adjustable delay, 1-15 seconds OFF
Adjustable pickup, 10-990 kW
Power Reversal Adjustable delay, 1-15 seconds OFF
Power Reversal Direction

1 MicroVersaTrip PM functions require 24 Vdc control power.


2 Ampere reading also standard on MicroVersaTrip Plus trip units.

8-54 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Low Voltage Power & Insulated Case Circuit Breakers Section 8
Trip Units
Product Number Nomenclature System

EntelliGuard TU Trip Unit for EntelliGuard G Breakers Product Number Structure

G G M 1 6 L 4 X 6 A R X X X X
Digit 1 and 2 3 4 and 5 6 and 7 8 9 10 11 12 13 14 15

Trip Unit
Form
EntelliGuard

Frame Ratings

Sensor Rating Future Use


1600

Overcurrent Ground Fault Protection


LSIG (S, switchable) (I, switchable ANSI only)

Zone Selective Interlocking Factory or Field Install


Blank Replacement Trip Unit

Advanced Features and Communications Manual / Auto Trip Reset (EntelliGuard G only)
Monitoring + Data Acquisition, Modbus Protocol + RELT Auto Reset/Reclose

Digit 1 and 2 Trip Unit Form/Family Digit 4 and 5 Sensor Rating


Circuit Breaker Type Code Sensor Rating Code
Power Break I (UL) GA UNIV1 00
Power Break II (UL) GB 400 04
AKR (ANSI) GC 6002 06
WP (ANSI) GW 800 08
Mpact Low (IEC) GL 10002 10
Mpact 24-48V (IEC) GH 12002 12
Mpact 120-240V (IEC) GQ 1600 16
EntelliGuard G ACB (ANSI) GG 2000 20
EntelliGuard G ACB (UL) GU 25002 25
EntelliGuard G ACB (IEC) GT 30002 30
EntelliGuard G Universal Spare Trip G1 32003 32
Type A Conversion Kits (ANSI) G2 4000 40
EntelliGuard G Switch (IEC) G3 5000 50
60002 60
1Universal Spare Trip Unit (Digit 3 = X)
2ULOnly
3ANSI Only

Digit 3 EntelliGuard G Frame Ratings


Interrupting Rating Tier ANSI/UL1066 Devices, LVPCB
1/2S Override
Code 254V 580V 635V Withstand HSIOC No. 1 Override WI
S 65,000 65,000 50,000 50,000 50,000 49,000 53,500
N 65,000 65,000 65,000 65,000 None None None
H 85,000 85,000 65,000 65,000 65,000 63,700 69,500
E 85,000 85,000 85,000 85,000 None None None
M 100,000 100,000 100,000 85,000 85,000 83,800 90,950
B 100,000 100,000 100,000 100,000 None None None
L 150,000 150,000 100,000 100,000 100,000 98,000 107,000
Interrupting Rating Tier UL489 Devices ICCB
1/2S Override
240V 480V 600V Withstand HSIOC No. 1 Override WI
S 65,000 65,000 50,000 42,000 42,000 N/A 44,940
N 65,000 65,000 65,000 42,000 42,000 N/A 44,940
H 85,000 85,000 65,000 50,000 50,000 N/A 53,500
M 100,000 100,000 100,000 65,000 65,000 N/A 69,550
L 150,000 150,000 100,000 85,000 85,000 N/A 90,950

Refer to GEH-4567 for other Circuit Breaker Types

Rev. 11/13 www.geindustrial.com BuyLog Catalog 8-55


Data subject to change
without notice
Low Voltage Power & Insulated Case Circuit Breakers Section 8
Trip Units
Product Number Nomenclature System

Digit 6 and 7 Overcurrent Protection Package


Type Over Current (OC) Protection Package Code
LSI (S, switchable) (I, switchable ANSI only) L3
LSIG (S, switchable) (I, switchable ANSI only) L4
LSIGA (S, switchable) (I, switchable ANSI only) (G, Alarm Only) L5
Standard Range LSIC (S, switchable) (I, switchable ANSI only) L6
Instantaneous LSICA (S, switchable) (I, switchable ANSI only) (C, Alarm Only) L7
LSIGDA1 (S, G, A switchable) (I, switchable ANSI only) L8
EntelliGuard G ANSI/UL LSIGCDA1 (S, G, C, A all switchable) (I, switchable ANSI only) L9
OC Protection LSH (S, switchable) (I, switchable ANSI only) LC
LSHG (S, switchable) (I, switchable ANSI only) LD
LSHGA (S, switchable) (I, switchable ANSI only) (G, Alarm Only) LE
Extended Range LSHC (S, switchable) (I, switchable ANSI only) LF
Adjustable Instantaneous LSHCA (S, switchable) (I, switchable ANSI only) (C, Alarm Only) LG
LSHGDA1 (S, G, A switchable) (I, switchable ANSI only) LH
LSHGCDA1 (S, G, C, A all switchable) (I, switchable ANSI only) LK
1Function Combination is NOT UL Listed
NOTES:
L = Long Time (L, I2T) + Fuse Settings (I4T) (Fuse settings are now standard on all EntelliGuard Trip Units)
S = Short Time (Switchable if Instantaneous (I) protection is enabled)
I = Standard Range Adjustable Instantaneous, (IOC, 2x-15x)
H = Extended Range Adjustable Instantaneous, (IOC, 2x-30x), Only for ANSI EntelliGuard G
G = Ground Fault Protection (GFP, 3-wire or 4-wire, internal summing) Trip and Alarm
C = External CT for ground fault detection (AKD20 application: input from external summing CTs, used for multiple source ground fault dectection.
OEM Application: Zero Sequence Input of 1A = 100%)
D = Defeatable/Switchable Ground Fault, NOT UL Listed
A = Ground Fault, External Ground Fault, Alarm only
GA = Ground Fault Alarm Only
CA = External Ground Fault Alarm Only
GDA, GCDA = Ground Fault Trip and Ground Fault Alarm (all switchable, Not UL Listed)

Digit 8 Zone Selective Interlocking (ZSI) Digit 10 Manual/Auto Trip Reset


Zone Selective Interlocking Code Manual/Auto Trip Reset Code
ZSI, Short time and GF; user seletable Z Manual Lockout M
Z+IOC or HIOC ZSI; user selectable T Auto Reset/Reclose A
Blank/none X Auto/Manual Lockout (Selectable)2 S2
None (Defaults to Auto Reset/Reclose) X
ZSI selections require Secondary Disconnect Block B and 24Vdc control power.
NOTE: Option X is the only valid item when a Switch is selected in Digit 2. Note: When Bell Alarm with Lockout is selected on the EntelliGuard G Circuit
Breaker, then Code M must be selected
X is only valid on GE Legacy Circuit Breakers and Conversion Kits
M is valid on EntelliGuard G Breakers when a Bell Alarm is selected
Digit 9 Advanced Features and Communications A is valid on EntelliGuard G Breakers when a Bell Alarm is not selected
2S is IEC Only
Advanced Features and Communications Code
Reduced Energy Let-Through (RELT) 1
Modbus Protocol + RELT 2
Profibus Protocol + RELT 3
Monitoring + RELT, NO Communication 4 Digit 11 Factory or Field Installed
Monitoring + Relay Package + RELT 5
Manual/Auto Trip Reset Code
Monitoring + Data Acquisition, Modbus Protocol + RELT 6
Monitoring + Data Acquisition, Profibus Protocol + RELT 7 Factory Installed Trip Unit (Original) F
Monitoring + Data Acquisition + Relay Package, Modbus + RELT 8 Replacement Trip Unit (shipped loose) R
Monitoring + Data Acquisition + Relay Package, Profibus + RELT 9
NONE X

NOTES:
All Advanced Feature selections require Secondary Disconnect Block B and
24Vdc control power
RELT = Reduced Energy Let Through
Monitoring = Advanced Metering
Data Acquisition = Waveform Capture and Harmonic Analysis

8-56 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Low Voltage Power & Insulated Case Circuit Breakers Section 8
Trip Units
Product Number Nomenclature System

EntelliGuard TU Trip Unit for Power Break, WavePro, AK/AKR, Conversion Kit Breakers Product Number Structure

G B 2 1 6 L 4 X 6 X R X X X X
Digit 1 and 2 3 4 and 5 6 and 7 8 9 10 11 12 13 14 15

Trip Unit
Form
Power
Break II

Frame Ratings
1600 Amp Frame

Sensor Rating Future Use


1600

Overcurrent Ground Fault Protection Original / Replacement Trip Unit


LSIG (S, switchable) (I, switchable ANSI only) F = Factory Installed (Original)
R = Replacement (Field Installed)
Zone Selective Interlocking
Blank
Manual / Auto Trip Reset
Advanced Features and Communications A, M, or S = EntelliGuard G only
Monitoring + Data Acquisition, Modbus Protocol + RELT X = for all others

Digit 1 and 2 Trip Unit Form/Family Digit 4 and 5 Sensor Rating


Circuit Breaker Type Code Sensor Rating Code
Power Break I (UL) GA 150 01
Power Break II (UL) GB 200 02
AK, AKR (ANSI) GC 225 03
WP (ANSI) GW 400 04
Mpact Low (IEC) GL 600 06
Mpact 24-48V (IEC) GH 800 08
Mpact 120-240V (IEC) GQ 1000 10
EntelliGuard G ACB (ANSI) GG 1200 12
EntelliGuard G ACB (UL) GU 1600 16
EntelliGuard G ACB (IEC) GT 2000 20
EntelliGuard G Universal Spare Trip G1 2500 25
Type A Conversion Kits (ANSI) G2 3000 30
EntelliGuard G Switch (IEC) G3 3200 32
4000 40
5000 50

Sensor must be equal to or less than Frame Rating

Digit 3 Legacy Frame Rating by Break Type


Breaker Type
AK, Westinghouse,
Code 3 Frame Rating Power Break I and II WavePro AKR ITE, Allis Chalmers
A 225A x
C 600A x
01 800A (AKR30S) x
1 800A x x x x
2 1600A x x x x
3 2000A x x x x
4 2500A x
5 3000A x x x
6 3200A x x x
7 4000A x x x x
8 5000A x
10 is used for only AKR30S breakers

Rev. 11/13 www.geindustrial.com BuyLog Catalog 8-57


Data subject to change
without notice
Low Voltage Power & Insulated Case Circuit Breakers Section 8
Trip Units
Product Number Nomenclature System

Digit 6 and 7 Overcurrent Protection Package


Type Over Current (OC) Protection Package Code
LSI (S, switchable) (I, switchable ANSI only) L3
PB1 and PBII, AK, AKR, LSIG (S, switchable) (I, switchable ANSI only) L4
WavePro, Conv Kits LSIGA (S, switchable) (I, switchable ANSI only) (G, Alarm Only) L5
Legacy ANSI/UL LSIGDA1 (S, G, A switchable) (I, switchable ANSI only) L8
OC Protection LSI (S, switchable) (I, Non-switchable UL891 applications) LP
LSIG (S, switchable) (I, Non-switchable UL891 applications) LQ
WavePro
LSIGA (S, switchable) (I, Non-switchable UL891 applications) (G, Alarm Only) LR
LSIGDA1 (S, G, A switchable) (I, Non-switchable UL891 applications) LS
1Function Combination is NOT UL Listed

NOTES: G = Ground Fault Protection (GFP, 3-wire or 4-wire, internal summing), Trip and Alarm
L = Long Time (L, I2T) + Fuse Settings (I4T) (Fuse settings are now standard on all D = Defeatable/Switchable Ground Fault, NOT UL Listed
EntelliGuard Trip Units) A = Ground Fault, Alarm only
S = Short Time (Switchable if Instantaneous (I) protection is enabled) GA = Ground Fault Alarm Only
I = Standard Range Adjustable Instantaneous, (IOC, 2x-15x) GDA = Ground Fault Trip and Ground Fault Alarm (all switchable, Not UL Listed)

Digit 8 Zone Selective Interlocking (ZSI) Digit 11 Original/Replacement Trip Unit


Zone Selective Interlocking Code Original/Replacement Code

ZSI, Short time and Ground Fault; user selectable Z Factory Installed (Original) F
ZSI, Instantaneous, Short Time, and Ground Fault; user selectable T Replacement (Field Installed) R
Blank/None X

All ZSI selections require a special harness (contact factory) and 24Vdc control power.
ZSI Instantaneous (T), Power Break can only be used as a Feeder (ZSI-I out)
EntelliGuard TU

Circuit Break Type Code 1 and 2


Digit 9 Advanced Features and Communications All Circuit Breakers G
Advanced Features Conv
and Communications Digit 9 WP PBII AKR Kits
NONE (Ammeter) X x x x OC Protection Package Code 6 and 7
Ammeter, Reduced Energy LSI (S, switchable) (I, switchable ANSI only) L3
1 x x x x
Let-Through (RELT) LSIG (S, switchable) (I, switchable ANSI only) L4
Ammeter, Modbus LSIGA (S, switchable) (I, switchable ANSI only) L5
2 x
Protocol + RELT LSIGDA2 (S, G, A all switchable) (I, switchable ANSI only) L8
Monitoring + Data Acquisition, JSI (S, switchable) (I, switchable ANSI only) J3
6 x x x
Modbus Protocol + RELT JSIG (S, switchable) (I, switchable ANSI only) J4
Monitoring + Data Acquisition + JSIGA (S, switchable) (I, switchable ANSI only) J5
8 x x x x
Relay Package, Modbus + RELT JSIGDA1 (S, G, A all switchable) (I, switchable ANSI only) J8
Ammeter, Modbus Protocol A x
(Without RELT)
Monitoring + Data Acquisition, Zone Selective Interlocking Code 8
D x x x
Modbus Protocol (without RELT)
None Selected X
Monitoring + Data Acquisition + E x x x x ZSI, Short time and GF; user selectable Z
Relay Package, Modbus (without RELT)
Z + IOC or HSIOC ZSI; user selectable T
NOTES:
All Advanced Feature selections require 24Vdc control power
RELT = Reduced Energy Let Through (Harness may be required, contact factory) Advanced Features and Communications Code 9
Monitoring = Advanced Metering (Harness may be required, contact factory) None Selected X
Data Acquisition = Waveform Capture and Harmonic Analysis Reduced Energy Let-Through (RELT) 1
Options A, D, E are available when Ground Fault Alarm is selected Modbus Protocol Only 2
Monitoring Only 4
Monitoring + Relay Package 5
Monitoring + Data Acquisition, Modbus Protocol 6
Monitoring + Data Acquisition + Relay Package, Modbus 8
Digit 10 Manual/Auto Trip Reset
1Function Combination is NOT UL Listed
Manual/Auto Trip Reset Code
Manual Reset (ANSI/UL EntelliGuard G Only) M
Automatic Reset (ANSI/UL EntelliGuard G Only) A
Automatic Reset (IEC EntelliGuard G Only) S
Not Applicable (Power Break, Power Break II, WavePro, AKR, Conv Kits) X

8-58 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Low Voltage Power & Insulated Case Circuit Breakers Section 8
Trip Units
Product Number Nomenclature System

EntelliGuard TU Trip Unit Rating Plug Product Numbers

GTP 1100 U 12 25
Trip Unit Type Rating
Largest Current Sensor Rating
GTP = Trip unit rating plug
01 = 150A 16 = 1600A
EntelliGuard TU Trip Unit
02 = 200A 20 = 2000A
03 = 225A 25 = 2500A
Rating Plug Ampere Rating
04 = 400A 30 = 3000A
0060 = 60A 1000 = 1000A
06 = 600A 32 = 3200A
0080 = 80A 1100 = 1100A
07 = 630A 40 = 4000A
0100 = 100A 1200 = 1200A
08 = 800A 50 = 5000A
0125 = 125A 1500 = 1500A
10 = 1000A 60 = 6000A
0150 = 150A 1600 = 1600A
12 = 1200A 64 = 6400A
0200 = 200A 1700 = 1700A
13 = 1250A
0225 = 225A 1800 = 1800A
0250 = 250A 1900 = 1900A
0300 = 300A 2000 = 2000A
0350 = 350A 2200 = 2200A Smallest Current Sensor Rating
0400 = 400A 2400 = 2400A 01 = 150A 16 = 1600A
0450 = 450A 2500 = 2500A 02 = 200A 20 = 2000A
0500 = 500A 3000 = 3000A 03 = 225A 25 = 2500A
0600 = 600A 3200 = 3200A 04 = 400A 30 = 3000A
0700 = 700A 3600 = 3600A 06 = 600A 32 = 3200A
0750 = 750A 4000 = 4000A 07 = 630A 40 = 4000A
0800 = 800A 5000 = 5000A 08 = 800A 50 = 5000A
0900 = 900A 6000 = 6000A 10 = 1000A 60 = 6000A
12 = 1200A 64 = 6400A
Trip Unit Type 13 = 1250A
U = Universal Trip Plug

Rev. 11/13 www.geindustrial.com BuyLog Catalog 8-59


Data subject to change
without notice
Low Voltage Power & Insulated Case Circuit Breakers Section 8
Trip Units
Product Number Nomenclature System

Power+ Trip Unit and Power Break II Product Numbers

D2 20 LSI T1 R1
Trip Unit Type and Rating Replacement or New
D2 = Power Break II Power+ Trip Unit: R = Replacement trip unit
2000 A sensor maximum (Blank) = New
D3 = Power Break II Power+ Trip Unit:
3000 A sensor maximum
D4 = Power Break II Power+ Trip Unit: Trip unit options
4000 A sensor maximum T1 = Target Module without ground fault target
T2 = Target Module with ground fault target
(Blank) = Factory Installed
Current Sensor Rating
02 = 200 A 20 = 2000 A
04 = 400 A 25 = 2500 A
08 = 800 A 30 = 3000 A Auxiliary functions
10 = 1000 A 40 = 4000 A LI = Long-time and Instantaneous
16 = 1600 A LSI = Long-time, Short-time, Instantaneous

1Device Product Number requires an extender R for field installable kit version only.
NOTE: This information is provided only for use interpreting product numbers. It cannot be used to build product numbers.

Power+ Rating Plug Product Numbers

TR 10 C 800 GF
Trip Unit Type Rating Ground Fault Function
TR = Trip unit rating plug Blank = No ground fault
All Power+, MicroVersaTrip Plus, GF = Ground fault
and MicroVersaTrip PM
rating plugs
Rating Plug Ampere Rating
Current Sensor Rating 100 = 100 A 800 = 800 A
02 = 200 A 20 = 2000 A 150 = 150 A 1000 = 1000 A
04 = 400 A 25 = 2500 A 200 = 200 A 1100 = 1100 A
08 = 800 A 30 = 3000 A 225 = 225 A 1200 = 1200 A
10 = 1000 A 40 = 4000 A 250 = 250 A 1500 = 1500 A
16 = 1600 A 300 = 300 A 1600 = 1600 A
400 = 400 A 2000 = 2000 A
Trip Unit Type 450 = 450 A 2500 = 2500 A
C = Power+ trip unit rating plugs 500 = 500 A 3000 = 3000 A
600 = 600 A 3600 = 3600 A
700 = 700 A 4000 = 4000 A
Power+ Target Module Product Numbers
TARGET00 = Blank insert for Target Module
TARGET01 = Target Module without ground fault target
TARGET02 = Target Module with ground fault target

NOTE: This information is provided only for use interpreting product numbers. It cannot be used to build product numbers.

8-60 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Low Voltage Power & Insulated Case Circuit Breakers Section 8
Trip Units
Product Number Nomenclature System

Power+ Trip Unit and Power Break II Product Numbers

J 3 32 LSI T1 R
Step 1 Step 2 Step 3 Step 4 Step 5 Step 6

Breaker Type Replacement


J = WavePro R = Replacement Trip Unit

Breaker Frame Target Module Installed


3 = 3200A TARGET01 (without ground fault)

Installed CT Overcurrent Protection


32 = 3200A LSI = Long Time, Short Time, Instantaneous

Power+ / WavePro

Step 1 Breaker Type Step 4 Overcurrent Protection


Breaker Type Code Overcurrent Protection Code
WavePro J Long-Time ( Standard) L
Short-Time (Optional) S
Instantaneous (Standard) I

Step 2 Breaker Frame


Breaker Frame (max CT) Code
Step 5 Target Module Installed
800A 8
Target Module Installed Code
1600A 1
2000A 2 TARGET00 (Blank Insert) (none)
3200A 3 TARGET01 (w/o ground fault) T1
4000A 4 TARGET02 (with ground fault) T2

Step 3 Installed CT Step 6 Replacement


Installed CT Code Replacement Code

150A 01 Replacement Trip Unit R


400A 04
800A 08
1600A 16
2000A 20
3200A 32
4000A 40

Rev. 11/13 www.geindustrial.com BuyLog Catalog 8-61


Data subject to change
without notice
Low Voltage Power & Insulated Case Circuit Breakers Section 8
Trip Units
Product Number Nomenclature System

MicroVersaTrip Plus, MicroVersaTrip PM Trip Unit and Power Break II Product Number

B2 20 LSI GZ1 PM R1
Trip Unit Type and Rating
B2 = Power Break II Enhanced
MicroVersaTrip Plus or PM Trip Unit:
2000 A Sensor maximum Remanufactured
B3 = Power Break II Enhanced RM = Remanufactured Trip Unit
MicroVersaTrip Plus or PM Trip Unit: RX = Exchanged Trip Unit
3000 A Sensor maximum
B4 = Power Break II Enhanced
MicroVersaTrip Plus or PM Trip Unit:
Trip Unit Options
4000 A Sensor maximum
Options for MicroVersaTrip PM trip units only. Must select one:
P = Protective relays & communications
Current Sensor Rating M = Metering & communications
02 = 200 A 20 = 2000 A PM = Protective relays, metering, & communications
04 = 400 A 25 = 2500 A (Blank) = MicroVersaTrip Plus trip unit
08 = 800 A 30 = 3000 A
10 = 1000 A 40 = 4000 A
16 = 1600 A
Ground Fault Functions
G = Ground fault
Auxiliary Functions GD = Ground fault defeatable (not UL listed)
LI = Long-time and instantaneous GZ1 = Ground fault; zone selective interlocking for ground fault only
LSI = Long-time, short-time, instantaneous GZ2 = Ground fault and short-time selective interlock
LSH = Long-time, short-time, high-range GDZ2 = Ground fault defeatable (not UL listed): ground fault and
instantaneous short-time selective interlock
(Blank) = None

1Device Product Number requires an extender R for field installable kit version only.
NOTE: This information is provided only for use interpreting product numbers. It cannot be used to build product numbers.

Rating Plug Product Numbers (MicroVersaTrip Plus and PM)

TR 10 B 800
Device Type
Rating Plug Ampere Rating
TR = Trip unit rating plug
100 = 100 A 1000 = 1000 A
All MicroVersaTrip Plus and
150 = 150 A 1200 = 1200 A
MicroVersaTrip PM rating plugs
200 = 200 A 1500 = 1500 A
225 = 225 A 1600 = 1600 A
300 = 300 A 2000 = 2000 A
Current Sensor Rating
400 = 400 A 2500 = 2500 A
2 = 200 A 20 = 2000 A
500 = 500 A 3000 = 3000 A
4 = 400 A 25 = 2500 A
600 = 600 A 3600 = 3600 A
8 = 800 A 30 = 3000 A
700 = 700 A 4000 = 4000 A
10 = 1000 A 40 = 4000 A
800 = 800 A
16 = 1600 A

Trip Unit Type


B = All Enhanced MicroVersaTrip Plus and MicroVersaTrip PM
trip unit rating plugs

NOTE: This information is provided only for use interpreting product numbers. It cannot be used to build product numbers.

8-62 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Low Voltage Power & Insulated Case Circuit Breakers Section 8
Trip Units
Product Number Nomenclature System

MicroVersaTrip Plus, MicroVersaTrip PM Trip Unit and WavePro Product Number

A 3 32 LSI G Z1 PM R
Step 1 Step 2 Step 3 Step 4 Step 5 Step 6 Step 7 Step 8

Breaker Type Remanufactured


A = AKR RM = Remanufactured Trip Unit
RX = Exchanged Trip Unit

Breaker Frame Optional Features


3 = 3200A PM = Relaying, Metering, Communication

Installed CT Optional Protection


04 = 400A Z1 = Ground Fault Zone - Selective Interlock

Overcurrent Protection Ground Fault Protection


LSI = Long Time, Short Time, Instantaneous G = Ground Fault

MVT PLUS/PM - WavePro

Step 1 Breaker Type Step 5 Ground Fault Protection


Breaker Type Code Ground Fault Protection Code
WavePro K Ground Fault G
Defeatable ground fault (user defeatbale) GD

Step 2 Breaker Frame


Frame Size Code Step 6 Replacement
Optional Protection Code
800A 8
1600A 1 Ground-Fault zone -selective interlock Z1
2000A 2 Ground-Fault and short-time ZSI Z2
3200A 3 Switchable instantaneous, short time and ground fault X
4000A 4
5000A 5

Step 7 Optional Features


Optional Features Code
Step 3 Installed CT Protective Relays and Communication P
Installed CT Code Metering and Communication M
150A 01
400A 04
600A 06
800A 08
Step 8 Remanufactured
1600A 16 Remanufactured Code
2000A 20 Remanufactured trip unit RM
3200A 32 Exchanged trip unit RX
4000A 40
5000A 50

Step 4 Overcurrent Protection


Overcurrent Protection Code
Long-Time ( Standard) L
Short-Time S
Instantaneous I

Rev. 11/13 www.geindustrial.com BuyLog Catalog 8-63


Data subject to change
without notice
Low Voltage Power & Insulated Case Circuit Breakers Section 8
Trip Units
Product Number Nomenclature System

MicroVersaTrip Plus, MicroVersaTrip PM Trip Unit and Power Break Product Number

C 2 08 LSI G Z1 PM R
Step 1 Step 2 Step 3 Step 4 Step 5 Step 6 Step 7 Step 8

Breaker Type Remanufactured


C = Power Break RM = Remanufactured Trip Unit
RX = Exchanged Trip Unit

Breaker Frame Communication, Metering and Relaying


2 = 800-2000A Maximum CT PM = Relaying, Metering, Communication

Installed CT Optional Functions


08 = 800A Z1 = Ground Fault Zone - Selective Interlock

Overcurrent Protection Ground Fault Protection


LSI = Long Time, Short Time, Instantaneous G = Ground Fault

MVT PLUS/PM - PowerBreak

Step 1 Breaker Type Step 5 Ground Fault Protection


Breaker Type Code Ground Fault Protection Code
Power Break C Ground Fault G
Defeatable ground fault (not UL Listed) GD

Step 2 Breaker Frame


Frame Size (max CT) Code Step 6 Optional Functions
Optional Functions Code
800-2000A 2
3000A 3 Ground-Fault zone -selective interlock Z1
4000A 4 Ground-Fault and short-time ZSI Z2

Step 3 Installed CT Step 7 Communication, Metering and Relaying


Installed CT Code Communication, Metering and Relaying Code
200A 02 Relaying and Communication P
400A 04 Metering and Communication M
600A 06
800A 08
1000A 10
1600A 16 Step 8 Remanufactured
2000A 20 Remanufactured Code
2500A 25
3000A 30 Remanufactured trip unit RM
4000A 40 Exchanged trip unit RX

Step 4 Overcurrent Protection


Overcurrent Protection Code
Long-Time ( Standard) L
Short-Time S
High Instantaneous H
Instantaneous I

8-64 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Low Voltage Power & Insulated Case Circuit Breakers Section 8
Trip Units
Product Number Nomenclature System

MicroVersaTrip Plus, MicroVersaTrip PM Trip Unit and AKR Product Number

A 2 04 LSI G Z1 PM R
Step 1 Step 2 Step 3 Step 4 Step 5 Step 6 Step 7 Step 8

Breaker Type Remanufactured


A = AKR RM = Remanufactured Trip Unit
RX = Exchanged Trip Unit

Breaker Frame Communication, Metering and Relaying


2 = 225-2000A maximum CT PM = Relaying, Metering, Communication

Installed CT Optional Functions


04 = 400A Z1 = Ground Fault Zone - Selective Interlock

Overcurrent Protection Ground Fault Protection


LSI = Long Time, Short Time, Instantaneous G = Ground Fault

MVT PLUS/PM - AKR

Step 1 Breaker Type Step 5 Ground Fault Protection


Breaker Type Code Ground Fault Protection Code
Power Break C Ground Fault G
Defeatable ground fault (not UL Listed) GD
W Curve W

Step 2 Breaker Frame


Breaker Frame (max CT) Code
225-2000A 2
Step 6 Optional Functions
3200A 3 Optional Functions Code
4000A 4 Ground-Fault zone - selective interlock Z1
Ground-Fault and short-time ZSI Z2
Switchable instantaneous short time and ground fault X

Step 3 Installed CT
Installed CT Code
150A 01 Step 7 Communication, Metering and Relaying
225A 03 Communication, Metering and Relaying Code
400A 04
600A 06 Relaying and Communication P
800A 08 Metering and Communication M
1600A 16
2000A 20
3000A 30
3200A 32 Step 8 Remanufactured
4000A 40 Remanufactured Code
Remanufactured trip unit RM
Exchanged trip unit RX

Step 4 Overcurrent Protection


Overcurrent Protection Code
Long-Time (standard) L
Short-Time S
High Instantaneous H
Instantaneous I
Fixed High Instantaneous K

Rev. 11/13 www.geindustrial.com BuyLog Catalog 8-65


Data subject to change
without notice
Low Voltage Power & Insulated Case Circuit Breakers Section 8
Trip Unit Conversion Kits

GE offers a complete line of trip unit upgrade kits for low voltage
power circuit breakers manufactured by GE, as well as by
Westinghouse, I-T-E, and Allis-Chalmers. These conversion kits
contain everything necessary to convert an old-style electro-
mechanical or solid-state trip unit to today's latest electronic,
digital technologyincluding the addition of metering, protective
relay, waveform capture, RELT, and communication functions.
All conversion kits designed by GE are tested to ANSI C37.59
standards for each breaker type so customers have the
assurance of safe, reliable operation.
Features and BenefitsAll Kits
Kit includes everything needed in one compact package
Full-range of interchangeable rating plugs
Trip targets for quick identification of overload, short circuit,
and ground fault trips
Sealable, see-through cover to prevent unauthorized access to
trip unit settings
Portable Trip Unit Test Kits; GTUTK20 and TVRMS2
Eliminate costly downtime due to nuisance tripping
Improved power system coordination and protection
Extend life and function of existing breakers and low voltage
equipment
AK-25 Breaker with EntelliGuard TU Trip Unit
EntelliGuard TU Conversion Kits
True RMS sensing with a sampling rate of 48 samples per cycle
with the ability to Waveform capture 4 cycles prior and 4 cycles
after an event
Long Time, Short Time, and Instantaneous Standard on all trip
units. S and I switchable on ANSI breakers
Large backlit LCD screen, view all currents on one screen
Trip settings and trip target information stored in non-volatile
memory
On-board lithium battery (field replaceable) for cold set-up and
reading trip targets
Status and Event Log, view the last 10 events
Health Status LED and Thermal Memory
Comm port for interface with set-up software and to download
Waveform
Optional metering, relaying, communications, ZSI - I, ground
fault (trip & alarm), and fused shaped curves
Plug and Play with previous generation of RMS9, EPIC, MVT and
Enhanced MVT Trip Units
ProTrip Conversion Kits EntelliGuard TU Conversion Kits
Cost-effective upgrade with standard adjustable long time,
short time, instantaneous, and defeatable ground fault functions Everything You Need in One Package
Simple-to-use rotary switches for selecting the trip unit pickup ProTrip and EntelliGuard TU conversion kits for the breakers
and delay settings listed in the following pages are shipped complete with detailed
True RMS sensing with sampling rate of 48 times per cycle installation instructions and everything needed for fast and easy
per phase - accurate waveform measurements through the trip unit conversions.
11th harmonic
Standard target module with individual LEDs for overload pick- Digital solid-state trip with quick disconnect
up, overload trip, short circuit trip, ground fault trip, and target Direct-acting flux shift trip actuator with automatic reset
module battery monitor Epoxy encapsulated high-accuracy current sensors
Interchangeable rating plug (order separately)
Specially designed mounting hardware and wire harnesses for
each breaker frame

8-66 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Low Voltage Power & Insulated Case Circuit Breakers Section 8
Trip Unit Conversion Kits for GE Circuit Breakers

EntelliGuard TU Conversion Kits


Upgrade your low-voltage equipment with
electronic trip unit technology.
Normal wear and tear of aging electro-mechanical trip devices
on low-voltage circuit breakers increases susceptibility to loss of
calibration that can subsequently jeopardize electrical power
system coordination, protection and reliability.
GE has channeled its decades of circuit breaker trip system
experience into the development of the EntelliGuard TU Trip
Unit. The EntelliGuard TU builds on the past trip units by incor-
porating advance algorithms that enable Arc Flash protection
and Selectivity at the same time.
ANSI C37.59 design verification tested to ensure safe, reliable
operation, these kits are designed to extend the life of your EntelliGuard TU Trip Unit Test Kit GTUTK20
mechanically sound breaker and
Eliminate costly downtime due to nuisance tripping. Improves Arc Flash and Selectivity at the same time
on past trip units with a Waveform Recognition Instantaneous The EntelliGuard TU Trip Unit offers optimum circuit protection
Algorithm and optimum system reliability simultaneously with little or no
Improve electrical power system coordination and protection compromise to either of these critical functions. Reliability and arc
Permit easy upgrades to communicating Power Management flash protection, in one package, at the same time, all the time.
Control Systems (PMCS), open Modbus RTU protocol
Algorithms enabling arc flash protection and selectivity
Enable the implementation of RELT and Zone Selective Interlock
Instantaneous to reduce Arc Flash Energy Levels. RELT Reduced Energy Let Through
Instantaneous Zone Selective Interlocking (I-ZSI)
Standard Features Waveform Recognition Instantaneous Coordinate with
Flexible Time Current Settings Current Limiting Devices and reduces Nuisance Trips
I2T Long Time, Long Time Delay Flexible Time Current Curves Create the shape you need
Short Time, Short Time Delay, 3 Short Time I2T Slopes
Reliability Health Status
Waveform Recognition Instantaneous
Ammeter Non-volatile memory with continuous self-testing microprocessor
Large Backlit LCD Screen1 Health Status LED indicates Normal Operation, Errors, Pick-up, Trip
Date and Time1 External Power Not Required with Long Life Lithium Battery
Breaker Status Indication Positive setpoint recognition, values flash until saved
Universal Rating Plugs Plug and Play
Status and Event Log (10 Events) Same Form, Fit, Function as the popular MicroVersaTrip Trip
LED Health Status Indicator1 Unit. Easily upgrade an existing converted breaker1
Set-up Software
I/O 1 Input and 1 Output1 Optional Full-function metering including1
Thermal Memory, Battery Back-up current (Amps, kAmps)
Common Interface across all versions voltage (Ph-Ph, Ph-N)
energy (kWh, MWh, GWh)
Optional
real power (kW, MW)
Internal/External Ground Fault Trip or Alarm with 4 curves to total power (kVA, MVA)
select from (I2T, I4T, SGF, Definite Time Slope)1 frequency (Hz)
Switchable Ground Fault Trip / Alarm (not UL Listed) demand (avg. kW, MW) and peak demand
Fused Long Time Curves (I4T)
Modbus Open RTU Communications1 Optional protective relaying functions include1
Waveform Capture Enables Harmonic analysis undervoltage
Full-function Metering1 overvoltage
Protective Relaying1 voltage unbalance
Zone Selective Interlock GF, S, I1 current unbalance
RELT Reduce Energy Let Through1 power reversal
RELT and Ground Fault Alarm Harness Kits power direction setup
Test Set GTUTK20
1Note: Some options require 24Vdc, additional hardware to enable Metering,
Relaying, RELT, ZSI, Modbus to be added to the Breaker, Equipment Cubicle,
and Equipment Sections.

Rev. 11/13 www.geindustrial.com BuyLog Catalog 8-67


Data subject to change
without notice
Low Voltage Power & Insulated Case Circuit Breakers Section 8
Trip Unit Conversion Kits for I-T-E, Westinghouse,
Allis-Chalmers Circuit Breakers
MicroVersaTrip PM Conversion Kits
Power Management Made Easy
The MicroVersaTrip PM trip unit's standard communication port
opens a new world of information. When connected to a GE
Power Management system, it gives you the power to increase

6 9 AV R D E E Y S R I P
productivity and reduce costs, while meeting all your electrical

S
system monitoring needs.

R AB MV E TE EN TU
The POWER LEADER Modbus Concentrator can be connected to
MicroVersaTrip PM trip units, allowing communication with the
GE Power Management Control System (PMCS) software. With

F O I L D P L W H TA
PMCS, you'll see how easy it is to:

8- E TU S E T C T
View custom metering screens and CAD drawings of our system

E R C I L A A
Analyze energy consumption and power factor trends to mini-

E T E. T .
mize utility demand and PF charges or provide cost allocations

LS EE P
G S A FA R Y S O E G R S

D L T D
Collect precise sequence of event and alarm information to Refer to BuyLog Section 22 for additional Power

AI S RI
speed diagnosis and minimize downtime Management components not supplied with the
Utilize alarm and event logs to assist with maintenance interval MicroVersaTrip PM conversion kits
PA I T U O B L V E

planning (voltage transformers, voltage conditioners,


Analyze system harmonics (with data from the POWER 24 Vdc power supplies, Modbus Concentrator,
LEADER family of meters) interconnection cables, and PMCS software)
N N T O N O

Use the POWER LEADER Modbus Concentrator to communi-


U A EN E I R

.
cate with MicroVersaTrip PM trip units on Spectra Series
molded case circuit breakers, Power Break II insulated case cir-
TS IC

cuit breakers, and AKR/WavePro power circuit breakers (refer to Reference Publications
BuyLog Section 22 for network architecture) GE MVT Plus and PM Conversion Kits DET-066
I-T-E MVT Plus and PM Conversion Kits DET-067
RE N LL I M

Communicate with Modbus RTU-supported electronic meters Westinghouse MVT Plus and PM Conversion Kits DET-093
and relays Allis-Chalmers MVT Plus and PM Conversion Kits DET-226
E
GE ProTrip Conversion Kits DET-228
I-T-E ProTrip Conversion Kits DET-229
:

Westinghouse ProTrip Conversion Kits DET-230


W U E

Additional Features Allis-Chalmers ProTrip Conversion Kits DET-231


I P OT

Full-function metering including


A
N

current (Amps, kAmps)


voltage (Ph-Ph, Ph-N)
B

energy (kWh, MWh, GWh)


TR N

real power (kW, MW)


total power (kVA, MVA)
frequency (Hz)
demand (avg. kW, MW) and peak demand
I

Optional protective relaying functions include


V

undervoltage
overvoltage
voltage unbalance
I

current unbalance
M

power reversal
power direction setup

8-68 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Low Voltage Power & Insulated Case Circuit Breakers Section 8
Remanufactured MVT Trip Unit
Overview and Features

Overview
GE is extending the lifecycle of this important component by
offering a remanufactured MVT solution. As of January 2012, GE
will no longer manufacture its MicroVersaTrip Plus and
MicroVersaTrip PM trip units.
GEs MVT Trip Units were manufactured from 1994 through 2011.
GEs latest Trip Unit model is the EntelliGuard TU, offering
improved selectivity and reliability. However, for those customers
not yet ready to upgrade, GE offers Remanufactured MVT Trip
Units to extend the lifecycle of this product for an additional 5 or
more years.
GE is committed to our customers through lifecycle support of
legacy equipment with quality services and solutions meeting
MicroVersaTrip Plus MicroVersaTrip PM
original specifications.
GE Remanufactured MVT Trip Units meet OEM specifications,
including new electronic boards and factory acceptance testing.

Key Features
Original GE parts
Complete replacement of all electronic circuit boards
Fully tested to original specifications
GE warranty
Standard next-day shipping; same-day shipping available
upon request
POWER LEADER communications network supported

Benefits
Longer life
GE Remanufactured MVT Trip Units allow you to extend the
lifecycle of your trip unit with service and remanufactured
products from GE.
Identical fit
GE Remanufactured MVT Trip Units are a plug-and-play unit
identical to your original unit in form, fit and function. Customers
are responsible for configuring the Remanufactured MVT Trip
Units to their specific system protection needs.
GE quality
GE Remanufactured MVT Trip Units have new electronic boards
and are fully tested to original manufacturers standards.
GE provides proven repair techniques and service from the
original manufacturer for your trip unit.

For more information, contact your local GE office,


call 1-888-GE4-SERV or 540-378-3280, or visit
www.geindustrial.com/services

Rev. 11/13 www.geindustrial.com BuyLog Catalog 8-69


Data subject to change
without notice
Low Voltage Power & Insulated Case Circuit Breakers Section 8
ProTrip Trip Unit Conversion Kit Selection Guide
For GE Circuit Breakers

Product Number Structure

PK115 D 3 F 01 08
Breaker Trip Functions
AK-1-15 PK115 LSIGX- 08
AK-15 PKO151
AK-1-25 Trip Unit Functions
PK125 Sensor Rating
AK-25 LSIGX- Long Time, Short Time/INST.
PKO251 150A- 01
and Switchable Ground Fault (off)
AKU-25 225A- 02
AK-1-50 PK150 Not Approved for a UL Listed Breaker
600A- 06
AK-50
800A- 08
AKU-502
1600A- 16
AKT-50 PKO501 2000A- 20
AKS-50
3000A- 30
AKSU-502
4000A- 40
AKST-50
Sensor Rating Selection
AK-753 PKO753 Frame Breaker Product Numbers Sensors
AK-1003 PKO103
225 AK-1-15, AK-15 150A, 225A
Model 600 AK-1-25, AK-25, AKU-25 150A, 225A, 600A
Generation-D AK-1-50, AK-50, AKU-50,
1600 800A, 1600A
AKS-50, AKSU-50
Wiring 2000 AKT-50, AKST-50 2000A
3 Wire-3 3000 AK-75 3000A
4 Wire-4 4000 AK-100 4000A

Sensor Type
Fixed CTs-F
1
For converting AK-2 version breakers and newer, not applicable for AK-1 or AKR
2
Breakers equipped with older style open fuse lockout devices (OFLO), must be
retrofitted with newer style OFLO device prior to conversion process.
Order replacement OFLO kits as follows: AKU-50 - order OFLO kit #121C287OG2,
AK-75 - order OFLO kit #121C287OG3, AK-100 - order OFLO kit #121C287OG4
3
Contact the factory for stationary breaker applications

ProTrip Conversion Kits


Frame Size (Amps) Breaker Model Wiring Sensor Rating Product Number
225 AK-1-15 3 Wire 150A PK115D3F0108
225 AK-1-15 3 Wire 225A PK115D3F0208
225 AK-1-15 4 Wire 150A PK115D4F0108
225 AK-1-15 4 Wire 225A PK115D4F0208
225 AK-15 3 Wire 150A PKO15D3F0108
225 AK-15 3 Wire 225A PKO15D3F0208
225 AK-15 4 Wire 150A PKO15D4F0108
225 AK-15 4 Wire 225A PKO15D4F0208
600 AK-1-25 3 Wire 150A PK125D3F0108
600 AK-1-25 3 Wire 225A PK125D3F0208
600 AK-1-25 3 Wire 600A PK125D3F0608
600 AK-1-25 4 Wire 150A PK125D4F0108
600 AK-1-25 4 Wire 225A PK125D4F0208
600 AK-1-25 4 Wire 600A PK125D4F0608
600 AK-25, AKU-25 3 Wire 150A PKO25D3F0108
600 AK-25, AKU-25 3 Wire 225A PKO25D3F0208
600 AK-25, AKU-25 3 Wire 600A PKO25D3F0608
600 AK-25, AKU-25 4 Wire 150A PKO25D4F0108
600 AK-25, AKU-25 4 Wire 225A PKO25D4F0208
600 AK-25, AKU-25 4 Wire 600A PKO25D4F0608
1600 AK-1-50 3 Wire 800A PK150D3F0808
1600 AK-1-50 3 Wire 1600A PK150D3F1608
1600 AK-1-50 4 Wire 800A PK150D4F0808
1600 AK-1-50 4 Wire 1600A PK150D4F1608
1600 AK-50, AKU-50, AKT-50, AKS-50, AKSU-50, AKST-50 3 Wire 800A PKO50D3F0808
1600 AK-50, AKU-50, AKT-50, AKS-50, AKSU-50, AKST-50 3 Wire 1600A PKO50D3F1608
1600 AK-50, AKU-50, AKT-50, AKS-50, AKSU-50, AKST-50 3 Wire 2000A PKO50D3F2008
1600 AK-50, AKU-50, AKT-50, AKS-50, AKSU-50, AKST-50 4 Wire 800A PKO50D4F0808
1600 AK-50, AKU-50, AKT-50, AKS-50, AKSU-50, AKST-50 4 Wire 1600A PKO50D4F1608
1600 AK-50, AKU-50, AKT-50, AKS-50, AKSU-50, AKST-50 4 Wire 2000A PKO50D4F2008
3000 AK-75 3 Wire 3000A PKO75D3F3008
3000 AK-75 4 Wire 3000A PKO75D4F3008
4000 AK-100 3 Wire 4000A PKO10D3F4008
4000 AK-100 4 Wire 4000A PKO10D4F4008
Conversion kits come standard with a rating plug that matches the current sensor. For rating plugs with different values, order separately. See page 8-74.

8-70 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Low Voltage Power & Insulated Case Circuit Breakers Section 8
ProTrip Trip Unit Conversion Kit Selection Guide
For *I-T-E Circuit Breakers

Product Number Structure

PIK22 D 3 F 02 08
Breaker Trip Functions
K225 PIK221 LSIGX- 08
K600
PIK601 Trip Unit Functions
KD0N600 Sensor Rating
K800 LSIGX- Long Time, Short Time/INST.
PIK801 150A- 01
and Switchable Ground Fault (off)
KD0N800 225A- 02
K1600 (black) Not Approved for a UL Listed Breaker
PIK1B1 400A- 04
KD0N1600 (black)
600A- 06
K1600 (red) PIK161,2
800A- 08
KD0N1600 (red) PIKN1,3
1600A- 16

Sensor Rating Selection


Frame Breaker Product Numbers Sensors
225 K225 150A, 225A
Model 600 K600, KD0N600 150A, 225A, 600A
Generation-D 800 K800, KD0N800 150A, 400A, 800A
K1600 (black),
Wiring 1600 KD0N1600 (black), 800A, 1600A
3 Wire-3 K1600 (red), KD0N1600 (red)
4 Wire-4

Sensor Type
Fixed CTs-F
1
Applicable to breakers originally equipped with either electro-mechanical
trip devices or with solid state trip devices ("S" version breakers).
2
Only applicable to breakers originally equipped with rectangular shaped
primary disconnect assemblies.
3
Only applicable to breakers originally equipped with circular shaped
primary disconnect assemblies.

ProTrip Conversion Kits


Frame Size (Amps) Breaker Model Wiring Sensor Rating Product Number
225 K225 3 Wire 150A PIK22D3F0108
225 K225 3 Wire 225A PIK22D3F0208
225 K225 4 Wire 150A PIK22D4F0108
225 K225 4 Wire 225A PIK22D4F0208
600 K600, KDON600 3 Wire 150A PIK60D3F0108
600 K600, KDON600 3 Wire 225A PIK60D3F0208
600 K600, KDON600 3 Wire 600A PIK60D3F0608
600 K600, KDON600 4 Wire 150A PIK60D4F0108
600 K600, KDON600 4 Wire 225A PIK60D4F0208
600 K600, KDON600 4 Wire 600A PIK60D4F0608
800 K800, KDON800 3 Wire 150A PIK80D3F0108
800 K800, KDON800 3 Wire 400A PIK80D3F0408
800 K800, KDON800 3 Wire 800A PIK80D3F0808
800 K800, KDON800 4 Wire 150A PIK80D4F0108
800 K800, KDON800 4 Wire 400A PIK80D4F0408
800 K800, KDON800 4 Wire 800A PIK80D4F0808
1600 K1600 (black), KDON1600 (black) 3 Wire 800A PIK1BD3F0808
1600 K1600 (black), KDON1600 (black) 3 Wire 1600A PIK1BD3F1608
1600 K1600 (black), KDON1600 (black) 4 Wire 800A PIK1BD4F0808
1600 K1600 (black), KDON1600 (black) 4 Wire 1600A PIK1BD4F1608
1600 K1600 (red) 3 Wire 800A PIK16D3F0808
1600 K1600 (red) 3 Wire 1600A PIK16D3F1608
1600 K1600 (red) 4 Wire 800A PIK16D4F0808
1600 K1600 (red) 4 Wire 1600A PIK16D4F1608
1600 KDON1600 (red) 3 Wire 800A PIKN1D3F0808
1600 KDON1600 (red) 3 Wire 1600A PIKN1D3F1608
1600 KDON1600 (red) 4 Wire 800A PIKN1D4F0808
1600 KDON1600 (red) 4 Wire 1600A PIKN1D4F1608
Conversion kits come standard with a rating plug that matches the current sensor. For rating plugs with different values, order separately. See page 8-74.

*I-T-E is a registered trademark of Siemens Energy and Automation, Inc.

Rev. 11/13 www.geindustrial.com BuyLog Catalog 8-71


Data subject to change
without notice
Low Voltage Power & Insulated Case Circuit Breakers Section 8
ProTrip Trip Unit Conversion Kit Selection Guide
For *Allis-Chalmers Circuit Breakers

Product Number Structure

PSL6B D 3 F 02 08
Breaker Trip Functions
LA-600 (blue) LSIGX- 08
PSL6B
LAF-600 (blue)
LA-600 (gold) Trip Unit Functions
PSL6G Sensor Rating
LAF-600 (gold) LSIGX- Long Time, Short Time/INST.
150A- 01
LA-800 (gold) and Switchable Ground Fault (off)
PSL8O 225A- 02
LAF-800 (gold) Not Approved for a UL Listed Breaker
400A- 04
LA-1600 (blue)
PSL1B 600A- 06
LAF-1600 (blue)
800A- 08
LA-1600 (gold)
PSL1G 1600A- 16
LAF-1600 (gold)

Model
Sensor Rating Selection
Generation-D
Frame Breaker Product Numbers Sensors
Wiring LA-600 (blue), LAF-600 (blue)
600 150A, 225A, 600A
3 Wire-3 LA-600 (gold), LAF-600 (gold)
4 Wire-4 800 LA-800 (gold), LAF-800 (gold) 150A, 400A, 800A
LA-1600 (blue), LAF-1600 (blue)
1600 800A, 1600A
Sensor Type LA-1600 (gold), LAF-1600 (gold)
Fixed CTs-F

ProTrip Conversion Kits


Frame Size (Amps) Breaker Model Wiring Sensor Rating Product Number
600 LA-600 (blue), LAF-600 (blue) 3 Wire 150A PSL6BD3F0108
600 LA-600 (blue), LAF-600 (blue) 3 Wire 225A PSL6BD3F0208
600 LA-600 (blue), LAF-600 (blue) 3 Wire 600A PSL6BD3F0608
600 LA-600 (blue), LAF-600 (blue) 4 Wire 150A PSL6BD4F0108
600 LA-600 (blue), LAF-600 (blue) 4 Wire 225A PSL6BD4F0208
600 LA-600 (blue), LAF-600 (blue) 4 Wire 600A PSL6BD4F0608
600 LA-600 (gold), LAF-600 (gold) 3 Wire 150A PSL6GD3F0108
600 LA-600 (gold), LAF-600 (gold) 3 Wire 225A PSL6GD3F0208
600 LA-600 (gold), LAF-600 (gold) 3 Wire 600A PSL6GD3F0608
600 LA-600 (gold), LAF-600 (gold) 4 Wire 150A PSL6GD4F0108
600 LA-600 (gold), LAF-600 (gold) 4 Wire 225A PSL6GD4F0208
600 LA-600 (gold), LAF-600 (gold) 4 Wire 600A PSL6GD4F0608
800 LA-800 (gold) 3 Wire 150A PSL80D3F0108
800 LA-800 (gold) 3 Wire 400A PSL80D3F0408
800 LA-800 (gold) 3 Wire 800A PSL80D3F0808
800 LA-800 (gold) 4 Wire 150A PSL80D4F0108
800 LA-800 (gold) 4 Wire 400A PSL80D4F0408
800 LA-800 (gold) 4 Wire 800A PSL80D4F0808
1600 LA-1600 (blue), LAF-1600 (blue) 3 Wire 800A PSL1BD3F0808
1600 LA-1600 (blue), LAF-1600 (blue) 3 Wire 1600A PSL1BD3F1608
1600 LA-1600 (blue), LAF-1600 (blue) 4 Wire 800A PSL1BD4F0808
1600 LA-1600 (blue), LAF-1600 (blue) 4 Wire 1600A PSL1BD4F1608
1600 LA-1600 (gold), LAF-1600 (gold) 3 Wire 800A PSL1GD3F0808
1600 LA-1600 (gold), LAF-1600 (gold) 3 Wire 1600A PSL1GD3F1608
1600 LA-1600 (gold), LAF-1600 (gold) 4 Wire 800A PSL1GD4F0808
1600 LA-1600 (gold), LAF-1600 (gold) 4 Wire 1600A PSL1GD4F1608

Conversion kits come standard with a rating plug that matches the current sensor. For rating plugs with different values, order separately. See page 8-74.

*Allis-Chalmers is a trademark of Allis-Chalmers Manufacturing Company Corporation.

8-72 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Low Voltage Power & Insulated Case Circuit Breakers Section 8
ProTrip Trip Unit Conversion Kit Selection Guide
For *Westinghouse Circuit Breakers

Product Number Structure

PDB15 D 3 F 02 08
Breaker Trip Functions
DB15, DBL15- PDB15 LSIGX- 08
DB25, DBL25- PDB25
Trip Unit Functions
DB50, DBL50- PDB50 Sensor Rating
LSIGX- Long Time, Short Time/INST.
DB75- PDB75 150A- 01
and Switchable Ground Fault (off)
DB100- PDB10 225A- 02
Not Approved for a UL Listed Breaker
600A- 06
Model
800A- 08
Generation-D
1600A- 16
3000A- 30
Wiring
4000A- 40
3 Wire-3
4 Wire-4
Sensor Rating Selection
Sensor Type Frame Breaker Product Numbers Sensors
Fixed CTs-F 225 DB15, DBL15 150A, 225A
600 DB25, DBL25 225A, 600A
1600 DB50, DBL50 800A,1600A
3000 DB75 3000A
4000 DB100 4000A

ProTrip Conversion Kits


Frame Size (Amps) Breaker Model Wiring Sensor Rating Product Number
225 DB15, DBL15 3 Wire 150A PDB15D3F0108
225 DB15, DBL15 3 Wire 225A PDB15D3F0208
225 DB15, DBL15 4 Wire 150A PDB15D4F0108
225 DB15, DBL15 4 Wire 225A PDB15D4F0208
600 DB25, DBL25 3 Wire 150A PDB25D3F0108
600 DB25, DBL25 3 Wire 225A PDB25D3F0208
600 DB25, DBL25 3 Wire 600A PDB25D3F0608
600 DB25, DBL25 4 Wire 150A PDB25D4F0108
600 DB25, DBL25 4 Wire 225A PDB25D4F0208
600 DB25, DBL25 4 Wire 600A PDB25D4F0608
1600 DB50, DBL50 3 Wire 800A PDB50D3F0808
1600 DB50, DBL50 3 Wire 1600A PDB50D3F1608
1600 DB50, DBL50 4 Wire 800A PDB50D4F0808
1600 DB50, DBL50 4 Wire 1600A PDB50D4F1608
3000 DB75 3 Wire 3000A PDB75D3F3008
3000 DB75 4 Wire 3000A PDB75D4F3008
4000 DB100 3 Wire 4000A PDB10D3F4008
4000 DB100 4 Wire 4000A PDB10D4F4008

Conversion kits come standard with a rating plug that matches the current sensor. For rating plugs with different values, order separately. See page 8-74.

*Westinghouse is a trademark of Westinghouse Electric Corporation.

Rev. 11/13 www.geindustrial.com BuyLog Catalog 8-73


Data subject to change
without notice
Low Voltage Power & Insulated Case Circuit Breakers Section 8
ProTrip Rating Plugs

ProTrip conversion kits come standard with a rating plug that


matches the current sensor. For rating plugs with different values,
price and order separately.

Reference Publications
ProTrip Trip Unit Conversion Kits for
GE Power Circuit Breakers - Fact Sheet DET-228
ProTrip Trip Unit Conversion Kits for
*Westinghouse Power Circuit Breakers - Fact Sheet DET-230
ProTrip Trip Unit Conversion Kits for
*Allis-Chalmers Power Circuit Breakers - Fact Sheet DET-231
ProTrip Trip Unit Conversion Kits for
*I-T-E Power Circuit Breakers - Fact Sheet DET-229 Rating Plug

Rating Plugs
Frame Size (Amps) Sensor Rating (Amps) Current Rating (Amps) Current Range (Amps) Product Number
225|600|800 150 80 40-88 PT1C80GFD
225|600|800 150 100 50-110 PT1C100GFD
225|600|800 150 125 63-138 PT1C125GFD
225|600|800 150 150 75-165 PT1C150GFD1
225|600|800 225 150 75-165 PT225C150GFD
225|600|800 225 225 113-248 PT225C225GFD1
600 600 300 150-330 PT6C300GFD
600 600 400 200-440 PT6C400GFD
600 600 450 225-495 PT6C450GFD
600 600 500 250-550 PT6C500GFD
600 600 600 300-660 PT6C600GFD1
800 400 200 100-220 PT4C200GFD
800 400 225 113-248 PT4C225GFD
800 400 250 125-275 PT4C250GFD
800 400 300 150-330 PT4C300GFD
800 400 400 200-440 PT4C400GFD1
800|1600 800 400 200-440 PT8C400GFD
800|1600 800 450 225-495 PT8C450GFD
800|1600 800 500 250-550 PT8C500GFD
800|1600 800 600 300-660 PT8C600GFD
800|1600 800 700 350-770 PT8C700GFD
800|1600 800 800 400-880 PT8C800GFD1
1600 1600 800 400-880 PT16C800GFD
1600 1600 1000 500-1100 PT16C1000GFD
1600 1600 1100 550-1210 PT16C1100GFD
1600 1600 1200 600-1320 PT16C1200GFD
1600 1600 1600 800-1760 PT16C1600GFD
2000 2000 1000 500-1100 PT20C1000GFD
2000 2000 1200 600-1320 PT20C1200GFD
2000 2000 1500 750-1650 PT20C1500GFD
2000 2000 1600 800-1760 PT20C1600GFD
2000 2000 2000 1000-2200 PT20C2000GFD
3000 3000 1200 600-1320 PT30C1200GFD
3000 3000 1600 800-1760 PT30C1600GFD
3000 3000 2000 1000-2200 PT30C2000GFD
3000 3000 2500 1250-2750 PT30C2500GFD
3000 3000 3000 1500-3300 PT30C3000GFD1
4000 4000 1600 800-1760 PT40C1600GFD
4000 4000 2000 1000-2200 PT40C2000GFD
4000 4000 2500 1250-2750 PT40C2500GFD
4000 4000 3000 1500-3300 PT40C3000GFD
4000 4000 3600 1800-3960 PT40C3600GFD
4000 4000 4000 2000-4000 PT40C4000GFD1
1Rating Plug furnished with conversion kit.
1Note: Long Time pickup range is 0.5-1.1 times the rating plug value. 1.1 setting allows the breaker to carry 100% of the rating plug current value, not to exceed the
continuous current (frame) rating of the breaker.

*I-T-E is a registered trademark of Siemens Energy and Automation, Inc.


*Westinghouse is a trademark of Westinghouse Electric Corporation.

8-74 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Low Voltage Power & Insulated Case Circuit Breakers Section 8

Intentionally left blank.

Rev. 11/13 www.geindustrial.com BuyLog Catalog 8-75


Data subject to change
without notice
Low Voltage Power & Insulated Case Circuit Breakers Section 8
EntelliGuard TU Trip Unit
Conversion Kits Selection Guide

AKO25 C 3 F 06 04 A

GE *Allis-Chalmers25 **I-T-E25 ***Westinghouse25


Breaker Breaker Breaker Breaker
AK-1-15 = AK11526 LA = ASL259 KA = AIKA210,11 DB-15 = ADB1526
AK-15 = AKO151 LA-25A = ASL2A9 K-225 = AIK22 DK-15 = ADK159
AK-1-25 = AK12526 LA-600(Blue) = ASL6B17,18 KB (metal) = AIKBM12 DB-25
= ADB25
AK-25 LAF-600(Blue) = ASL6B17,18,19 KB (slate drawout) = AIKBS12 DBL-25
= AKO251
AKU-25 LA-600(Gold) = ASL6G18,20 KB (slate stationary) = AIKBX12 DK-25 = ADK259
AKR-30 LAF-600(Gold) = ASL6G18,19,20 K-600 DS-206
= AIK60 = ADS06
AKR-30H = AKR30 LA-50(800A) = ASL589,21 KDON-600 DSL-206
AKRU-30 LA-800 = ASL8018,20 KC (800A) = AIKC810,12,14 DA-50 = ADA509
AKR-30S LAF-800 = ASL8018,19,20 K-800 DB-50
= AKR3S2 = AIK80 = ADB50
AKRU-30S RL-800 = ASR80 KDON-800 DBL-50
AK-1-50 = AK150 RLX-800 = ASR16 KC (1600A) = AIKC110,12,13 DS-416
= ADS16
AK-50 RLE-800 = ASR80 K-1600 (red) = AIK1615 DSL-416
AKU-50 3 LA-50(1600A) = ASL519,22 K-1600 (black) DS-420 = ADS20
= AIK1B15
AKT-50 = AKO501 LA-50(1600A) = ASL529,23 KDON-1600 (black) DS-532 = ADS53
AKS-50 LA-1600(Blue) = ASL1B17,18 KDON-1600 (red) = AIKN1 DA-75 = ADA759
AKSU-50 3 LAF-1600(Blue) = ASL1B17,18,19 K-2000 = AIK20 DB-75 = ADB75
AKST-50 LA-1600(Gold) = ASL1G18,20 KD = AIKD316 DS-632 = ADS32
AKR-50 LAF-1600(Gold) = ASL1G18,19,20 K-3000 = AIK30 DA-100 = ADA109
AKR-50H RL-1600 = ASR16 KE = AIKE416 DB-100 = ADB10
AKRU-50 RLX-1600 = ASR16 LG = AIKG49 DS-840 = ADS40
AKRT-50 RLE-1600 = ASR16 K-4000 = AIK40
AKRT-50H = AKR504 RL-2000 = ASR0
AKJ-50 LA-75 = ASL759
AKJ-50H LA-3000 = ASL3018
AKJT-50 LA-3200(Blue) = ASL3B9,17,18
AKJT-50H LA-3200(Gold) = ASL3G9,18,20
AK-753 = AKO755 RL-3200 = ASR32
AKR-75 = AKR755 LA-4000(Blue) = ASL4B17,18,26
AK-100 3 = AKO105 LA-4000(Gold) = ASL4G18,20
AKR-100 = AKR105 RL-4000 = ASR40
AKW-100 = AKW105
Blue = Blue-gray breaker with plastic escutcheon
Gold = Gold breaker with metal escutcheon

Sensor Rating Selection


Breaker Catalog Numbers

Frame Sensors GE *Allis-Chalmers **I-T-E ***Westinghouse


150
225 AK-1-15, AK-15 Sensor rating not available. KA, KA-225 DB-15, DK-15
225
150
600 225 AK-1-25, AK-25, AKU-25 LA-25, LA-25A, LA-600,
KB, K-600, KDON-600 DB-25, DBL-25, DK-25
600 LAF-600
150
AKR-30, AKR-30H, AKRU-30, LA-50 (800A Version), LA-800, LAF-800, KC (800A Version),
800 400 DS-206, DSL-206
AKR-30S, AKRU-30S RL-800, RLE-800, RLX-800 K-800, KDON-800
800

800 AK-1-50, AK-50, AKU-50, AKS-50, LA-50 (1600A Version),


KC (1600A Version), DA-50, DB-50, DBL-50,
1600 AKSU-50, AKR-50, AKR-50H, LA-1600, LAF-1600, RL-1600,
K-1600, KDON-1600 DS-416, DSL-416
1600 AKRU-50, AKJ-50, AKJ-50H RLE-1600, RLX-1600

AKT-50, AKST-50, AKRT-50,


2000 2000 RL-2000 K-2000 DS-420
AKRT-50H, AKJT-50, AKJT-50H
3000 3000 AK-75 LA-75, LA-3000 KD, K-3000 DA-75, DB-75
3200 3200 AKR-75 LA-3200, RL-3200 DS-632
4000 4000 AK-100, AKR-100, AKW-100 LA-4000, RL-4000 KE, LG, K-4000 DA-100, DB-100, DS-840

*Allis-Chalmers is a trademark of Allis-Chalmers Manufacturing Company Corporation.


**I-T-E is a registered trademark of Siemens Energy and Automation, Inc.
***Westinghouse is a trademark of Westinghouse Electric Corporation.

8-76 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Low Voltage Power & Insulated Case Circuit Breakers Section 8
EntelliGuard TU Trip Unit
Conversion Kits Selection Guide

Model Sensor Ratings Trip Functions Adv. Options


C = Generation 150A = 01 04 = LSI2 A = Ammeter
225A = 02 05 = LSIG2 B = Ammeter + RELT24
400A = 04 09 = LSIGDA C = Advanced Metering, Relaying,
600A = 06 11 = LSH2 Waveform Capture, Modbus Comm,
800A = 08 12 = LSHG2 RELT24
Wiring 1600A = 16
3 Wire = 3 2000A = 20
6
ZSI Instantaneous is available.
4 Wire = 4 3000A = 30
8
Contact factory.
3200A = 32
Trip Unit Functions RELT (Reduced Energy Let Through)
4000A = 40
150A No CTs7 = XA
LSI = Long Time, Short Time (Switchable), Order RELT Switch Kit GTURSK separately
7 & Instantaneous (Switchable)
400A No CTs = XC
Sensor Type LSIG = LSI & Ground Fault Trip
800A No CTs7 = XE
F = Fixed CTs 7 LSIGDA = LSIG with Switchable Ground
1600A No CTs = XF
7 Fault Alarm (not UL Listed)
2000A No CTs = XG
7,8 LSH = Long Time, Short Time (Switchable),
3200A No CTs = XI
7 High Range Instantaneous
4000A No CTs = XJ
(Non-Switchable) Up to 22KA
(AKR30S Only)2
LSHG = LSH & Ground Fault Trip
(AKR30S Only)2

Reference Publications 1For converting AK-2 version breakers and newer, not applicable for AK-1 or AKR.
2AKR30S Instantaneous Is Non-Switchable and the Non-Switchable High Range
EntelliGuard TU Conversion Kit Brochure DET-722
EntelliGuard TU Conversion Kit Supplemental Instructions DEH-3456 Instantaneous max is 22KA. LSH and LSHG Are Only Available on AKR30S.
EntelliGuard TU Trip Unit Installation/Instruction Manual DEH-4567 3Breakers equipped with older style open fuse lockout devices (OFLO), must be
EntelliGuard TU Test Set - GTUTK20 DEH-4568A retrofitted with newer style OFLO device prior to conversion process. Order
GE AK-1-15, AK-1-25 GEH-6466 replacement OFLO kits as follows: AKU-50 - order OFLO Kit #121C2870G2,
GE AK-1-50 DEH-40027 AK-75 - order OFLO kit #121C2870G3, AK-100 - order OFLO kit #121C2870G4.
GE AK-15, AK, AKU-25, AKR-30S, AKRU-30S GEH-5967 4Not applicable for converting breakers equipped with Power Sensor - contact
GE AKR-30,30H, AKRU-30, AKR-50, AKJ-50 Series GEH-5966
GE AK-100, AK,U,T,S,SU,ST-50, AK-75 GEH-5965
factory.
5Contact the factory for stationary breaker applications.
GE AKR-100, AKR-75, AKW-100 GEH-5964
6Only applicable to trip units with ground fault.
Westinghouse DB-15 GEH-6318
Westinghouse DB-25, DBL-25 (225A), DB-50, DBL-50 GEH-6319 7Available only for MicroVersaTrip RMS-9 type AKR breakers equipped with fixed
Westinghouse DS-206, DSL-206, DS416, DSL-416, DS-420, DS-632 DEH-023 current sensors.
Westinghouse DB-100 (4000A), DB-75 (3000A) GEH-6320 8Not available on AK-75 breaker frames.
ITE K-1600 (red), K, KDON-1600 Black, K-2000, K-225, K-600, 9Contact factory for availability.
KDON-600, K-800, KDON-800, KDON-1600 (red) GEH-6294 10Not applicable for slate version breakers.
ITE KC (1600A), KC (800A) GEH-6433 11Left pole accessories must be removed or relocated.
ITE KA GEH-6293
12Right pole accessories must be removed or relocated.
ITE KB (Metal), KB (Slate Drawout), KB (Slate Fixed) GEH-6295
131600-amp version of the KC breaker.
ITE K-3000, K-4000 DEH-133
ITE KD-3000, KE-4000 DEH-40019 14800-amp version of the KC breaker.
Allis Chalmers LA, LAF - 1600 (BLUE), LA, LAF-600 (BLUE) DEH-40008 15Order for red or black insulator as applicable.
Allis Chalmers LA, LAF - 1600 (GOLD), LA, LAF-600 (GOLD), LA, LAF-800, 16Not applicable to fixed mounted breakers.
RL, RLX, RLE-1600 & 800 DEH-40009A 17Only applicable for blue-gray color version breakers.
18Applicable to both A and B version breakers.
19Applicable to both nameplated versions of integral fused breakers
(i.e., LA-600F and LAF-600).
20Only applicable for gold color version breakers.
21800-amp version of the LA-50 breaker.
22Only applicable for the 1600-amp, 6-pole primary disconnect version of
the LA-50 breaker.
23Only applicable for 1600-amp, 12 pole primary disconnect version of the
LA-50 breaker.
24Requires 24Vdc control power.
25Existing Allis-Chalmers, I-T-E and Westinghouse bell alarms will not work
with EntelliGuard TU.
26Trip Unit will be mounted horizontally on breaker.
Note: Conversion Kit tables are located on pages 8-78
through 8-80.

Rev. 11/13 www.geindustrial.com BuyLog Catalog 8-77


Data subject to change
without notice
Low Voltage Power & Insulated Case Circuit Breakers Section 8
EntelliGuard TU Trip Unit
Conversion Kits Selection Guide
EntelliGuard TU are determined by the Frame Rating, Breaker
Model, 3 or 4 wire, Trip Functions, and Advanced Features.
(Example: Items highlighted in bold AKO25 C 3 F 06 04 A)

For GE Power Circuit Breakers


EntelliGuard TU Trip Unit Conversion Kits for 3-Phase, 3-Wire
LSI (04) LSIG (05) LSIGDA (09)
Breaker Ammeter All Advanced Ammeter All Advanced Ammeter All Advanced
Frame Amps Model Ammeter (A) + RELT (B) Options (C) Ammeter (A) + RELT (B) Options (C) Ammeter (A) + RELT (B) Options (C)

225 AK115
AKO15
AK125
600
AKO25
AKR30
800
AKR3S
AK150
1600 AKO50
AKR50
AK150
2000 AKO50
AKR50
3000 AKO75
3200 AKR75
AKO10
4000 AKR10
AKW10

For GE Power Circuit Breakers


EntelliGuard TU Trip Unit Conversion Kits for 3-Phase, 4-Wire
LSI LSIG (04) LSIGDA (09)
Breaker Ammeter All Advanced Ammeter All Advanced Ammeter All Advanced
Frame Amps Model Ammeter (A) + RELT (B) Options (C) Ammeter (A) + RELT (B) Options (C) Ammeter (A) + RELT (B) Options (C)
AK115
225
AKO15
AK125
600
AKO25
AKR30
800
AKR3S
AK150
1600 AKO50
AKR50
AK150
2000 AKO50
AKR50
3000 AKO75
3200 AKR75
AKO10
4000 AKR10
AKW10

For *Allis-Chalmers Power Circuit Breakers


EntelliGuard TU Trip Unit Conversion Kits for 3-Phase, 3-Wire
LSI (04) LSIG (05) LSIGDA (09)
Breaker1 Ammeter All Advanced Ammeter All Advanced Ammeter All Advanced
Frame Amps Model Ammeter (A) + RELT (B) Options (C) Ammeter (A) + RELT (B) Options (C) Ammeter (A) + RELT (B) Options (C)
ASL6B
600
ASL6G
ASL80
800
ASR80
ASL1B
1600 ASL1G
ASR16
2000 ASR0
3000 ASL30
3200 ASR32
ASR40
4000 ASL4G
ASL4B
1Contact factory for breaker models not listed.

*Allis-Chalmers is a trademark of Allis-Chalmers Manufacturing Company Corporation.

8-78 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Low Voltage Power & Insulated Case Circuit Breakers Section 8
EntelliGuard TU Trip Unit
Conversion Kits Selection Guide

For *Allis-Chalmers Power Circuit Breakers


EntelliGuard TU Trip Unit Conversion Kits for 3-Phase, 4-Wire
LSI LSIG (05) LSIGDA (09)
Breaker1 Ammeter All Advanced Ammeter All Advanced Ammeter All Advanced
Frame Amps Model Ammeter (A) + RELT (B) Options (C) Ammeter (A) + RELT (B) Options (C) Ammeter (A) + RELT (B) Options (C)

600 ASL6B
ASL6G
ASL80
800
ASR80
ASL1B
1600 ASL1G
ASR16
2000 ASR0
3000 ASL30
3200 ASR32
ASR40
4000 ASL4G
ASL4B

For **I-T-E Power Circuit Breakers


EntelliGuard TU Trip Unit Conversion Kits for 3-Phase, 3-Wire
LSI (04) LSIG (05) LSIGDA (09)
Breaker1 Ammeter All Advanced Ammeter All Advanced Ammeter All Advanced
Frame Amps Model Ammeter (A) + RELT (B) Options (C) Ammeter (A) + RELT (B) Options (C) Ammeter (A) + RELT (B) Options (C)

225 AIKA2
AIK22
AIKBM
AIKBS
600 AIKBX
AIK60
800 AIKC8
AIK80
AIKC1
AIK16
1600 AIK1B
AIKN1
2000 AIK20
3000 AIK30
4000 AIK40

For **I-T-E Power Circuit Breakers


EntelliGuard TU Trip Unit Conversion Kits for 3-Phase, 4-Wire
LSI LSIG (05) LSIGDA (09)
Breaker1 Ammeter All Advanced Ammeter All Advanced Ammeter All Advanced
Frame Amps Model Ammeter (A) + RELT (B) Options (C) Ammeter (A) + RELT (B) Options (C) Ammeter (A) + RELT (B) Options (C)
AIKA2
225
AIK22
AIKBM
AIKBS
600
AIKBX
AIK60
AIKC8
800
AIK80
AIKC1
AIK16
1600
AIK1B
AIKN1
2000 AIK20
3000 AIK30
AIKE4
4000
AIK40
1Contact factory for breaker models not listed.

*Allis-Chalmers is a trademark of Allis-Chalmers Manufacturing Company Corporation.


**I-T-E is a registered trademark of Siemens Energy and Automation, Inc.

Rev. 11/13 www.geindustrial.com BuyLog Catalog 8-79


Data subject to change
without notice
Low Voltage Power & Insulated Case Circuit Breakers Section 8
EntelliGuard TU Trip Unit
Conversion Kits Selection Guide
For *Westinghouse Power Circuit Breakers
EntelliGuard TU Trip Unit Conversion Kits for 3-Phase, 3-Wire
LSI (04) LSIG (05) LSIGDA (09)
Breaker1 Ammeter All Advanced Ammeter All Advanced Ammeter All Advanced
Frame Amps Model Ammeter (A) + RELT (B) Options (C) Ammeter (A) + RELT (B) Options (C) Ammeter (A) + RELT (B) Options (C)
225 ADB15
600 ADB25
800 ADS06
ADB50
1600
ADS16
2000 ADS20
3000 ADB75
3200 ADS32
ADB10
4000
ADS40

For *Westinghouse Power Circuit Breakers


EntelliGuard TU Trip Unit Conversion Kits for 3-Phase, 4-Wire
LSI LSIG (05) LSIGDA (09)
Breaker1 Ammeter All Advanced Ammeter All Advanced Ammeter All Advanced
Frame Amps Model Ammeter (A) + RELT (B) Options (C) Ammeter (A) + RELT (B) Options (C) Ammeter (A) + RELT (B) Options (C)
225 ADB15
600 ADB25
800 ADS06
ADB50
1600
ADS16
2000 ADS20
3000 ADB75
3200 ADS32
ADB10
4000
ADS40
1Contact factory for breaker models not listed.

EntelliGuard TU Trip Rating Plug Specifications 2WavePro and AKR only. EntelliGuard G min. trip plug is 150A.
May Be Used With Trip Plug
3PowerBreak only. EntelliGuard G min. trip plug is 150A.
Plug Minimum Maximum Sensor 4WavePro and AKR only. EntelliGuard G min. sensor is 400A.
Rating Rating Sensor Product Number
5PowerBreak only. EntelliGuard G min. sensor is 400A.
60 A2 150A4 150A4 GTP0060U0101 6IEC only sensor, UL equivalents are 600A.
80A2 150A4 150A5 GTP0080U0101 7For ITE and Allis Chalmers 4000A breakers.
100A3 150A4 225A5 GTP0100U0103
125A2 150A4 225A5 GTP0125U0103
150A 150A4 400A GTP0150U0104
200A 200A5 400A GTP0200U0204
225A 225A 600A GTP0225U0306
250A 400A 630A1 GTP0250U0407
300A 400A 800A GTP0300U0408
350A 400A 800A GTP0350U0408
400A 400A 1000A GTP0400U0410
450A 600A 1200A GTP0450U0612
500A 600A 1250A1 GTP0500U0613
600A 600A 1600A GTP0600U0616
700A 800A 1600A GTP0700U0816
750A 800A 2000A GTP0750U0820
800A 800A 2000A GTP0800U0820
900A 1000A 2000A GTP0900U1020
1000A 1000A 2500A GTP1000U1025
1100A 1200A 2500A GTP1100U1225
1200A 1200A 3200A GTP1200U1232
1500A 1600A 4000A GTP1500U1640
1600A 1600A 4000A GTP1600U1640
1900A 2000A 5000A GTP1900U2050
2000A 2000A 5000A GTP2000U2050
2200A 2500A 5000A GTP2200U2550
2400A 2500A 6400A6 GTP2400U2564
2500A 2500A 6400A6 GTP2500U2564
3000A 3000A 6400A6 GTP3000U3064
3200A 3200A 6400A6 GTP3200U3264
3600A 4000A 6400A6 GTP3600U4064
4000A 4000A 4000A6 GTP4000U40407
4000A 4000A 6400A6 GTP4000U 4064
5000A 5000A 6400A6 GTP5000U5064 *Westinghouse is a trademark of Westinghouse Electric Corporation.
6000A 6000A 6400A6 GTP6000U6064

8-80 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Low Voltage Power & Insulated Case Circuit Breakers Section 8
EntelliGuard TU Trip Unit
Conversion Kit Accessories and Hardware
AK, AKR, Westinghouse, ITE, Allis Chalmers Conversion Kits
EntelliGuard TU trip unit and rating plug
Direct acting flux shifter with automatic reset
Epoxy encapsulated high-accuracy current transformers
Specially designed mounting hardware and wire harnesses with
communication cable and RELT harness for easy upgrade later
Detailed instruction manual

EPIC, RMS9, MVT+, MVT PM Upgrade Options


EntelliGuard TU trip unit and rating plug
RELT and Ground Fault Alarm Harness Kits (see below)
RELT Switch with warning labels kit GTURSK
Communication cable for Modbus & 24 VDC
Power Break II carrier plate assemblies
(authorized service only)
WavePro secondary disconnect kits

Harness Kits and Hardware to add RELT (Reduced Energy Let Through)
Breakers Component Product Number Description
24V Power Supply PLPS4G01 Power Leader 1.5A power supply for up to 15 trip units
All RELT Switch Kit GTURSK Includes blue lighted RELT switch, lockable cover, contacts,
8 wire harness, warning labels (see picture above)
RELT Harness Kit GTURHB 4 wire RELT & Ground Fault Alarm harness kit. Used to add RELT
or Ground Fault Alarm to an existing MVT installation in combination with an
EntelliGuard TU. Harness comes with breaker and cubicle side, 8 feet of
wire, terminal block, and RELT labels. Includes 9 pin harness for 24VDC,
AK, AKR, Allis Chalmers,
communications, and voltage source.
ITE, Westinghouse
RELT Harness Kit GTURHA 4 wire RELT & Ground Fault Alarm harness kit. Used to add RELT or
Ground Fault Alarm to an existing MVT installation in combination with
an EntelliGuard TU. Harness comes with breaker and cubicle side, 8 feet
of wire, terminal block, and RELT labels1
WavePro - 800-2000A RELT Harness Kit GTURHWP1 6 wires (4 for RELT, 2 for 24VDC) from trip unit to secondary
disconnect block. Used to add RELT to an existing MVT Installation.
WavePro - 3200-4000A RELT Harness Kit GTURHWP2 6 wires (4 for RELT, 2 for 24VDC) from trip unit to secondary
disconnect block. Used to add RELT to an existing MVT Installation.

Rev. 11/13 www.geindustrial.com BuyLog Catalog 8-81


Data subject to change
without notice
Low Voltage Power & Insulated Case Circuit Breakers Section 8
EntelliGuard TU Trip Unit
Conversion Kit Accessories and Hardware
Harness Kits and Hardware to add RELT (Reduced Energy Let Through) (continued)
Breakers Component Product Number Description
WavePro - 5000A RELT Harness Kit GTURHWP3 6 wires (4 for RELT, 2 for 24VDC) from trip unit to secondary
block. Used to add RELT to an existing MVT Installation.
WavePro - All Frames WavePro C Disconnect Block GTUSDWP1 WavePro breaker side secondary disconnect C
WavePro - 800-2000A GTUSFSD361 WavePro equipment side secondary disconnect C,
WavePro C Disconnect Block
WavePro - 3200-5000A GTULFSD361 includes 36 wire harness1
TDOSD6S Power Break I secondary disconnect 6 circuit drawout -
equipment side
Power Break I Disconnect
Power Break I - All Frames TDOSD6B Power Break I secondary disconnect 6 circuit drawout -
Block
breaker side
TDOSVD04 Power Break I secondary disconnect with Zone Interlocking
Stationary Power Break II RELT Harness Kit GTURHPB2S 6 wires (4 for RELT, 2 for 24VDC) and complete wired carrier
plate. Used to add RELT to an exisitng MVT Installation.
(Installation by authorized service only)
Drawout Power Break II RELT Harness Kit GTURHPB2D 6 wires (4 for RELT, 2 for 24VDC), complete wired carrier plate,
and 6 wire harness from terminal block to secondary
disconnect. Used to add RELT to an exisitng MVT installation.
(Installation by authorized service only)
Power Break II - All Frames Power Break II B SPDOSD36S Power Break II secondary disconnect block B - equipment side
Disconnect Block SPDOSD36B Power Break II secondary disconnect block B - breaker side
1WavePro equipment side secondary disconnect C is available as 16 wire harness: GTUSFSD361 and GTULFSD361.

Additional Key Components


Breakers Component Product Number Description
ZSI Module TIM1 Zone Selective Interlock Module/Repeater
Voltage Conditioners PLVC1G01 Supplies isolated bus voltage signal from PTs to
(set of 3) EntelliGuard Trip Units (PTs not included)
Voltage Conditioners Plate See Page 8-45 Voltage Conditioners and Potential Transformers mounted
(set of 3) BuyLog on a metal plate with fuses
Voltage Conditioner, PTs Includes Voltage Conditioners, Potential Transformers,
All (set of 3) and Power Supply See Pub DEP-056A 24V DC and Fuses all mounted on one Metal Plate
Used for testing phase currents, ground fault, disabling
EntelliGuard TEST Kit GTUTK20 ground fault, RELT. Ability to Trip Breaker and used to
connect to a PC with Set-up Software to download settings
Rating Plug Removal Tool TRTOOL Simplifies rating plug removal
Set-up Software GTUSS Set-up EntelliGuard Trip Unit offline or connected.
Ability to view Waveform Captured by Trip Unit
AK, AKR, Allis Chalmers, 9 Pin Wire Harness GTUCHCONV1 9 Pin Equipment side wire harness 8 long for 24VDC,
ITE, Westinghouse Equipment side Communications, Voltage Conditioner Input
WavePro - All Frames Plastic Door Kit 10060051P3 WavePro Trip Unit Plastic Door
Power Break I - All Frames Power Break Micro Switch See Pub DEH40391 Replacement Microswitch on Power Break Is with EPIC
Trip Units
Power Break II - All Frames Plastic Door Kit 10054335P3 Power Break II Trip Unit Plastic Door
2RELT and Ground Fault Alarm require 24VDC. If 24VDC cable is required order GTURHB

EntelliGuard TU Trip Units are compatible with MicroVersaTrip, RMS9, EPIC RMS9, MicroVersaTrip Plus and PM,
Enhanced MicroVersaTrip Plus and PM Trip Units models.

Now Available:
Power Break II in a Power Break I (fixed and drawout)
EntelliGuard R Retrofill (EntelliGuard G in AKD-5,
AKD-6, AKD-8 switchgear line-ups)
Contact factory for availability and options

8-82 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Low Voltage Power & Insulated Case Circuit Breakers Section 8
Trip Unit
Accessories

Optional Remote DisplayFeatures


Provides safe, convenient closed-door access to breaker
metering, status and setup functions
Available for use with either MicroVersaTrip Plus or
MicroVersaTrip PM trip units
Rugged plastic NEMA Type 1 enclosure with LCD and keypad
Mounts easily on outside of breaker compartment door
Sealable, clear LEXAN protective cover over display and "Enter"
key prohibits unauthorized trip setting changes
Connects to breaker trip unit via 20-pin plug-in cable for fast
installation
Breaker trip unit operates independently if cable is disconnected
Optional Remote Display

Optional Remote Display (for MicroVersaTrip)


Accessory Type Product Number
Remote Display w/ 6 Cable REMDIS1
Replacement Cable REMDIS2

Target Module (for ProTrip)


All ProTrip conversion kits come with a target module. Target Module
Order another only for renewal purposes.
Product Number
TARGET02P

GE Trip Unit Portable Test Set (for MicroVersaTrip and ProTrip)


Allows for self-tests and functioning trip/no trip tests. Operates on
batteries (not included) or 120 VAC source.
Product Number
TVRMS2

GE Trip Unit Portable Test Set

EntelliGuard TU Test Set


Allows for self-tests and functioning trip/no trip tests. Operates on
batteries (not included) or 120 VAC source.
Product Number
GTUTK20

EntelliGuard TU Test Set

Rev. 11/13 www.geindustrial.com BuyLog Catalog 8-83


Data subject to change
without notice
Low Voltage Power & Insulated Case Circuit Breakers Section 8
Trip Unit
Accessories

POWER LEADER Power Supply


The POWER LEADER power supply provides 24Vdc control power to MicroVersaTrip PM trips units used on WavePro low voltage
power circuit breakers. The control power is required for the trip units communication and protective relay functions.
System Requirements
Description Product Number (Not included with power supply)
1.5A power supply. PLPS4G01 Input power, 100VA
Maximum wire length from power supply (85-265 Vac or 100-370 Vdc)
to trip device is 100 feet. A maximum of 45 trip
units may be powered from a single power supply.

POWER LEADER Voltage Conditioner


Conditions and scales 120Vac to 1.76Vac for use by the trip unit for voltage sensing. Provides transient protection. Requires isolation
PTs with 120 volt secondary. Supports up to 15 trip units at a maximum distance of 20 feet. Required for PM trip units only.
System Requirements
Description Product Number (Not included with voltage conditioners)
Supplies isolated bus voltage signal PLVC1G01 One set of 3 voltage conditioners required
to MicroVersaTrip PM trip units. for each sensing location. PTs also required.

MicroVersaTrip Portable Power Pack


The MicroVersaTrip Portable Battery Pack is a maintenance power source used to power up trip units for setting or adjusting trip set
points or for reading trip targets when the trip unit is not otherwise energized. It is a redundant power source to the onboard battery
supplied with the Enhanced MicroVersaTrip Plus and PM (5-button keypad) trip units. The portable battery pack connects to the trip
unit through the rating plug test jack. It requires three (3) standard 9Vdc alkaline batteries (not included).

Description Product Number


MicroVersaTrip Portable Power Pack TVPBP

MicroVersaTrip and EntelliGuard Rating Plug Removal Tool

Description Product Number


MicroVersaTrip and EntelliGuard Rating Plug Removal Tool TRTOOL

8-84 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Low Voltage Power & Insulated Case Circuit Breakers Section 8
Asbestos Free Arc Quencher Replacement Kits

GEs Asbestos Free Arc Quencher Replacement Kits are designed


to replace asbestos plate style arc quenchers on AK and early
AKR power circuit breakers with reliable, proven steel plate style
arc quenchers used on modern AKR breakers. The kits have been
ANSI C37.59 tested for dielectric and short circuit ensuring break-
er performance to original specifications. On most AK series
breakers, no modifications are needed to install the arc quencher
replacement kit. Installation is typically done in less than one
hour (see Installation Instructions GEH-6464). Asbestos Free Arc
Quencher replacement kits are shipped complete with detailed
installation instructions and everything you need for fast and
easy arc quencher replacement:
Asbestos free metal plate or ceramic arc quenchers
Contact guides and arc runners (when required)
Asbestos free replacement barriers (when required)
All required mounting hardware
Reference Publications
Asbestos Free Arc Quencher Replacement Kits DET-096
Installation Instructions GEH-6464

Product Number Selection

AKO25 AQR1 G1
Breaker Model Application
AK-15 AQR1 Arc Quencher Replacement Kit For Asbestos Removal G1
AK-25 AKO25 1,2,3 Generation 1 Renewal Kit for G2
AKU-25 Ceramic Arc Quenchers
AKR-30S AKR3S 1,2
AKR-30
AKR30
AKRU-30
Arc Quenchers Replacement Kit
AKR-30H
AKR3H
AKRU-30H Product Number
AK-50 AKO25AQR1 G1
2,3
AKT-50 AKO50 AKR3SAQR1 G1
AKU-50 AKR30AQR1 G1
AKR30AQR1 G2
AKJ-50
AKR3HAQR1 G1
AKJT-50 AKR3HAQR1 G2
AKJU-50 AKR50 AKO50AQR1 G1
AKR-50 AKR50AQR1 G1
AKRT-50 AKR50AQR1 G2
AKRU-50 AKR5HAQR1 G1
AKR5HAQR1 G2
AKJ-50H
AKD50AQR1 G1
AKJT-50H AKD50AQR1 G2
AKJU-50H AKD5HAQR1 G1
AKR5H
AKR-50H AKD5HAQR1 G2
AKRT-50H AKO75AQR1 G1
AKR75AQR1 G1
AKRU-50H
AKO10AQR1 G1
AKJ-50 AKR10AQR1 G1
AKJT-50 AKD50 4
AKJU-50
AKJ-50H
AKJT-50H AKD5H 4
AKJU-50H
AK-75 AKO75 2,3
AKR-75 AKR75 2
AK-100 AKO10 2,3
AKR-100 AKR10 2

1Kits contain replacement barriers only, arc quenchers do not contain asbestos.
2G2 kits are not available for these breakers, please contact the factory for individual replacement arc quenchers.
3Does not apply to AK-1 series breakers.
4These kits are for use on breakers used in AKD and AKD-5 switchgear and substructures.

Rev. 11/13 www.geindustrial.com BuyLog Catalog 8-85


Data subject to change
without notice
Low Voltage Power & Insulated Case Circuit Breakers Section 8
Gerapid High Speed DC Circuit Breakers

Typical Traction Electric Power System


Rectifier CBs Feeder CBs distribute
protect converters DC to the track

AC bus duct DC bus duct

Electric utility Primary switchgear, 5kV-38kV Transformer Heavy duty traction rectifier DC switchgear

Third rail
or overhead
contact system

In addition to traction substation applications, Gerapid can be used as a feeder breaker in various other installations such as industrial
plants (metals industry), as field breakers for motor and generator field applications, and as disconnects for DC drives, to name a few.

Circuit Breaker Features and Accessories Key Benefits


Insulated side plates with adjustable dial for setting over current Standard dimensions from 2,600A to 6,000A (feeder models
trip (OCT) (optional) GER2607 GER8007)
Mechanical forced tripping Operating voltages from 1,000 to 3,600Vdc
Electrodynamic trip device (with or without capacitor and Mining and traction compliant (ANSI C37.14, IEC 947-2,
charging unit) EN 50123-2). Also available with UL label.
Shunt trip High speed OPEN/TRIP (opening delay <3ms)
No-voltage release Direct acting instantaneous and adjustable trip unit works
Breaker auxiliary contacts (up to 10 form C) without imported energy and is available as bidirectional
Additional auxiliary contacts for signaling (optional) symmetrical (for line feeder) or undirectional (for rectifier breaker)
Main terminal configurations variable High speed CLOSE (approximately 150 ms)
Plug connectors for auxiliary circuits (optional) Solenoid drive (integral control unit, mechanically latched, no
Hand lever for manual actuation from front (for maintenance auxiliary power required to keep contacts closed)
purposes only) 2-stage contact system minimizes contact wear
Position indication (optional) Compact, enclosed construction
Internal power supply with a wide range of supply voltage Modular, serviceable design
options Easily accessible control and auxiliary connections
Integrated current measurement unit (SEL) (optional) Fixed and draw-out versions
Mechanical counter Extensive accessories/options

General Information
Rated Temperature -5 to 40C ambient (55C with reduced ratings)
Relative Humidity 90% @ T<20C; RH=130-2*T @ T>20 C
Altitude -120m to 2000m above sea level

8-86 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Low Voltage Power & Insulated Case Circuit Breakers Section 8
Gerapid High Speed DC Circuit Breakers

Gerapid Breaker Modules Power and Control Connections

Control circuits
screw terminals and
Arc chute plug-in connectors
(1x2 shown, 1,000Vdc)

Arc chute adapter

Insulated side plates


(optional)

Instantaneous trip
mechanically operated,
adjustable (optional)

Electronic control unit

Basic breaker with drive


mechanism and
contact system
Main terminals, horizontal
Solenoid drive and vertical, top and bottom

Type SEL Current Measurement System


(optional on 2607 and 4207)
Current measurement at the breaker
Factory-equipped or field-installable
No additional space required or breaker modifications
Ranges 6kA and 12kA
To 4,000Vdc
Signal output via 3 interfaces
4...20mA
+/- 20mA
+/- 10V
Watchdog function standard

Rev. 11/13 www.geindustrial.com BuyLog Catalog 8-87


Data subject to change
without notice
Low Voltage Power & Insulated Case Circuit Breakers Section 8
Gerapid High Speed DC Circuit Breakers

Technical Data for Feeder Circuit Breaker Models 2607 through 8007
Breaker type Gerapid 2607 Gerapid 4207 Gerapid 6007 Gerapid 8007

Arc chute type 1X2 1X4 2X2 2X3 2X4 1X2 1X4 2X2 2X3 2X4 1X2 1X4 2X2 2X3 2X4 1X2 2X2

Conventional thermal current Ith [A] (IEC/EN) 2600 4200 6000 8000

Rated current [A] (ANSI/IEEE C37.14) 2600 4150 N/A 6000

Rated voltage UNe [V] (EN 50123 / IEC 60947) 1000 2000 2000 3000 3600 1000 2000 2000 3000 3600 1000 2000 2000 3000 3600 1000 2000

Rated maximum voltage [V] (ANSI/IEEE C37.14) 800 N/A N/A N/A N/A 800 N/A 1600 N/A N/A N/A N/A N/A N/A N/A 800 N/A

Rated insulation voltage Ui [V] (EN 50123 / IEC 60947) 2000 2000 2000 3000 4000 2000 2000 2000 3000 4000 1000 2000 2000 3000 4000 1000 2000

Short time current 120 min [A] (EN 50123 / IEC 60947) 3150 5000 7200 9600

Short time current 2 min [A] (EN 50123 / IEC 60947) 5200 8500 12000 16000

Short time current 20 sec [A] (EN 50123 / IEC 60947) 7800 12600 18000 24000

Impulse withstand voltage 1.2/50 s Ui [kV]


18 18 18 30 30 18 18 18 30 30 12 18 18 30 * 12 18
according to EN 50124-1:1997

Power frequency withstand voltage 50 Hz Ua [kVeff]


10 10 10 15 15 10 10 10 15 15 7 10 10 15 * 7 10
according to EN 50124-1:1997

Rated short circuit making capacity Nss [kA] 70 50 100 50 42 70 50 100 50 42 70 50 80 50 * 70 *

Rated short circuit breaking capacity INss [kA] 50 35 71 35 30 50 35 71 35 30 50 35 56 35 * 50 50


according to EN 50123-2

Rated service short circuit breaking current Ics [kA]


60 40 50 40 40 60 40 50 40 40 60 40 50 40 * 60 *
according to IEC 947-2

Short circuit current according to IEEE C37.14 [kA] 120 120 60 120 *

Peak current according to IEEE C37.14 [kA] 200 200 100 200 *

Maximum short circuit current [kA]


244 120 100 52 244 120 100 52 200 240
tested at customer request

Maximum arc voltage Uarc [kV] (EN 50123 / IEC 60947) 2 4 4 5.6 7 2 4 4 5.6 7 2 4 4 5.6 7 2 4

Weight ca. [kg] 120 120 160 160 160 120 120 160 160 160 150 150 165 165 165 190 210

Weight ca. [lbs] 265 265 352 352 352 265 265 352 352 352 331 331 364 364 364 419 463

*Test data available at customer request

Technical Data for Rectifier Circuit Breaker Models 8007R and 10007R
Parameter Reference Gerapid 8007R Gerapid 10007R
Arc chute type N/A 1x2 1x3 1x2 1x3
Rated continuous current [A] ANSI C37.14 p.5.3 6000 6000 8000 8000
2 hours current [A] N/A 7200 7200 9600 9600
2 minutes current [A] N/A 12000 12000 16000 16000
20 seconds current [A] N/A 18000 18000 24000 24000
Rated short-time current (250ms) [kA] ANSI C37.14 p.5.5 90 (149 peak) 60 (100 peak) 90 (149 peak) 60 (100 peak)
Rated maximum voltage [V] ANSI C37.14 p.5.2 800 1200 800 1200
Rated insulation voltage - UNm [V] EN 50124-1 p.1.3.2.4 2000 2000 2000 2000
Rated impulse voltage - UNi [kV] EN 50124-1 p.1.3.2.7 18 [12/50 s] 18 [12/50 s] 18 [12/50 s] 18 [12/50 s]
Power frequency voltage Ua [kV] EN 50124-1 a.B 2.2 10 [1 minute 50 Hz] 10 [1 minute 50 Hz] 10 [1 minute 50 Hz] 10 [1 minute 50 Hz]
Mechanical endurance [cycles] 1 N/A 10.000 10000 10000 10000
Rated short circuit peak / sustained current [kA] 2,3 ANSI C37.14 p.5.4 200 / 120 132 / 80 200 / 120 132 / 80
Short-circuit characteristic Tests a, b, c, d acc. ANSI C37.14 annex A High-speed High-speed High-speed High-speed
Maximum arc voltage [V] N/A 2500 2500 2500 2500
Mass ca. N/A 220 kG 220 kG 220 kG 220 kG
110000 cycles without parts replacement. Inspection after 5000 cycles. Max. 5000 cycles by means of ED impulse coil or POCT release.
2Tested for high and low frequency impedance bonds.
3Trip by means of POCT (direct-acting, instantaneous, electromechanical and polarized OC release) or by means of ED impulse coil with no intentional delay

To configure Gerapid OEM Modules and DC Circuit Breakers, visit our web\ wizard configuration tool at:
http://www.geindustrial.com/cwc/Dispatcher?REQUEST=PRODUCTS&id=gerapid&lang=en_US

8-88 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Low Voltage Power & Insulated Case Circuit Breakers Section 8
Gerapid High Speed DC Circuit Breakers

Figure 1. Models 2607 - 6007 Feeder CBs, 1X4 Arc Chute, 2,000Vdc (Dimensions in mm)

Figure 2. Gerapid 8007 Feeder CBs, 1X4 Arc Chute, 2,000Vdc (Dimensions in mm)

Rev. 11/13 www.geindustrial.com BuyLog Catalog 8-89


Data subject to change
without notice
Low Voltage Power & Insulated Case Circuit Breakers Section 8
Gerapid High Speed DC Circuit Breakers

Figure 3. Gerapid 8007R and 10007R Rectifier CB, 1X2 Arc Chute, 800Vdc
(Dimensions in mm)

8-90 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Low Voltage Power & Insulated Case Circuit Breakers Section 8
Power Break II Circuit Breakers
Features

Power Break II Circuit Breakers


The Insulated Case Circuit BreakerGE pioneered the design
and created the name in 1965. GE Power Break II insulated case
circuit breakers are the latest in reliable, flexible and easy-to-use
circuit protection.
Power Break II circuit breakers are UL Listed, CSA and IEC-947-2
Certified for up to 200,000 amperes, at 240 volts rms symmetrical
interrupting capacity without fuses or current limiters. These new
insulated case circuit breakers rated 200-4000A can be applied
on ac power systems through 600 volts. All breaker frames,
except 4000A stationary, are UL Listed to carry 100% of their
ampere rating continuously. All frames are suitable for reverse
feeding.
All Power Break II circuit breakers are available in two levels
of interrupting capacitystandard break and Hi-Break
breakers. Each interrupting level is available in both stationary
and draw-out construction, with a full complement of control
and signaling accessories.
Standard break breakers are designed to meet the majority of
application requirements, calling for moderate levels of available
GEs innovative, modular, drop-in accessories provide the ultimate
short-circuit current.
customer solution for field customization:
Hi-Break breakers are specially designed to withstand the stress-
UL Listed
es, and safely interrupt high levels of short-circuit current found
Accessory combination (one each) shunt trip, undervoltage
in some applications (from 65 to 200 kA rms symmetrical
release, bell alarm (alarm only), bell alarm with lockout.
amperesdepending on voltage).
Rated 12-250 Vdc through 12-240 Vac, continuous duty.
Complete installation in seconds without special tools, breaker
Greater Convenience and Operational Safety disassembly or adjustment
The controls and status indicators you need most are readily The user can select how protective trip unit functions, the
accessible. The flush-mounted handle, ON/OFF buttons, rating shunt trip (with or without lockout), and UVR accessories
plug test receptacle, bell alarm reset buttons with or without interface with the bell alarm and bell alarm with lockout
lockout are easily reached and all are double-insulated from accessories: An overcurrent, shunt trip, or UVR trip can
live components. And, for added security, a standard padlock be set to actuate the bell alarm or bell alarm with lockout.
device lets you prevent accidental or unauthorized closing of Any combination of output actions based on inputs can
the breaker. be selected.
Shunt trip and undervoltage trip targets are clearly displayed
Power Break II circuit breakers are versatile and designed for
by the trip unit LCD.
a wide variety of applications including temperature insensitive
trip units, push-to-open and close control, charge-after-close Pre-wired wire harness makes field installation a snap for:
operation, 3 cycle closing, UL listed (file E 11592) field installable Motor operator with remote charge indicator
accessories suitable for 50/60 Hz. All accessories and control Auxiliary switches, up to 12-stage maximum
wiring are prewired to dedicated, secondary terminal points on Remote close solenoid
each breaker. Additional field-installable accessories including:
Kirk Key locks (4 maximum)
Limited access ON/OFF cover
Quick, Error-Free Installation of Universal Accessories
Mechanical operations counter
Drop-in bell alarm, bell alarm with manual reset lockout, shunt Door interlock
trip, shunt trip with lockout, and undervoltage release install in Walking beam interlock for stationary and draw-out breakers.
seconds. No special tools. No breaker disassembly. Just slide
them into place. The modules are universal across all frame sizes
and each is mechanically keyed to its compartment so you make Ratings for Global Use
the right connection, every time. These accessories are field Performance ratings include IEC947-2 certification.
installable and upgradable.

Rev. 11/13 www.geindustrial.com BuyLog Catalog 8-91


Data subject to change
without notice
Low Voltage Power & Insulated Case Circuit Breakers Section 8
Power Break II
Construction Options

The interruption ratings and voltages shown in the table are


maximum ratings. A circuit breaker of the type given in the left-
hand column may be applied at the given circuit voltage in any
electrical distribution system where the available fault current
at the load terminals of the breaker does not exceed the value
in the table. That circuit breaker type may also be applied at
intermediate values of circuit voltage provided the available
fault current at the load terminals of the breaker does not
exceed the value in the table for the higher value of voltage.

Insulated Case Circuit Breakers


Trip Types
Circuit Breaker
Envelope Size EntelliGuard MicroVersaTrip Molded Max IC @ Max Voltage Max Frame
(Amperes) TU Power+ Plus/PM Case Switch 480V (kA) Rating (ac) (Amperes)
Power Break II
800 X X X 65 600 800
1600 X X X 65 600 1600
Standard 2000 X X X 65 600 2000
3000 X X X 100 600 3000
4000 X X X 100 600 4000
800 X X X 100 600 800
1600 X X X 100 600 1600
Hi-Break 2000 X X X 100 600 2000
3000 X X X 150 600 3000
4000 X X X 150 600 4000
800 X 301 600 800
1600 X 401 600 1600
Molded 2000 X 401 600 2000
Case Switch 2500 X 421 600 2500
3000 X 421 600 3000
4000 X 421 600 4000

1Molded case switch ratings are short time @ 600Vac, not interrupting current. See page 8-108 for withstand ratings.

8-92 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Low Voltage Power & Insulated Case Circuit Breakers Section 8
Power Break II Circuit Breakers
EntelliGuard TU Trip Unit Features

EntelliGuard TU Trip Units


New capabilities in the EntelliGuard TU Trip Unit provide ultimate
system reliability and selectivity without sacrificing circuit protec-
tion. This superior addition enhances the Power Break II breaker
with a Waveform Recognition Instantaneous Algorithm that elimi-
nates costly downtime due to nuisance tripping. It enables
harmonic analysis four cycles prior and after an event, and dis-
cerns whether a downstream breaker/fuse is clearing the fault.
The unit also includes Zone Selective Interlocking (can be used as
a feeder and downstream device with a power circuit breaker
upstream) which delivers simultaneous and independent ZSI of
Short Time, Ground Fault and Instantaneous protection, providing
the ability to overlap the Instantaneous on the Main and Feeder
breakers. Together, these innovative abilities achieve Hazard Risk
Category 2 (HRC2) with currents as high as 100kA with simultane-
ous flash protection and selectivity.
The EntelliGuard TU Trip Unit offers optimum circuit safety
and arc flash protection with the Reduced Energy Let-Through
function, providing a faster instantaneous trip that may be
used if faster and more sensitive protection is required
temporarily. It is commonly referred to as an Arc Flash Switch
or Maintenance Switch.
The new and improved trip unit design delivers selectivity tools Maintenance and Diagnostics
not previously available in GE circuit breakers: Universal trip plug fits any trip unit.
Flexible serial communication via Modbus RTU
Integrates directly into GEs EnerVista Power Management
Exclusive EntelliGuard TU Trip Unit Features System.
Designed for Flexibility Large backlit LCD with detailed, easy-to-see descriptions.
A wide range of continuous adjustment Long Time delays Health status via breaker LED indicating normal operation,
ensure the circuit breaker can be exactly adjusted in to your errors, pickup, and trips while providing non-volatile memory
selectivity and protection needs. with a continuous self-testing microprocessor
Multiple Short Time diagonal bands tune your protection to Lithium battery to eliminate need for external power for
exactly where it needs to be. set-up and review
Flexible time current settings and curves -Standard Long Time 10 event Log with Date/Time Stamp: Stores the last 10 events.
characteristics exactly mimic the curve of a thermal magnetic Date/Time with 24Vdc Power.
circuit breaker. Thermal Memory
Flexible Time Current Curves: 44 Long Time Shapes I2T and WaveForm Capture: 40 Samples/Cycle, 4 cycles prior and 4
I4T (fuse), 3 Short Time I2T slopes, Short Time adjustable in 55 cycles post event in COMTRADE format.
ms increments, and 4 Ground Fault curves to select from (I2T, Free set-up software
I4T, SGF, Define Time Slope)
Instantaneous Protection
Instantaneous pick-up is adjustable up to 15 times the plug
rating on frames 800-2000A, 13 times on 3000A frames and
up to 9 times on 4000A frames.
A separately adjustable fast instantaneous trip - useful for
when the circuit must provide the best possible protection
and arc flash performance while sustaining normal load.
An override instantaneous - provides fast tripping for the
largest bolted fault currents to minimize potential damage.
Up to 17 Short Time bands allow you to set your circuit break-
er to sustain load requirements without slowing protection.
Ground Fault Alarm via I/O or Modbus Communications
Ground fault protection with faster time bands, multiple
slopes and the ability to coordinate a 1200A ground fault
with an 800A circuit breaker a ratio four times better than
in previous generation trip units

Rev. 11/13 www.geindustrial.com BuyLog Catalog 8-93


Data subject to change
without notice
Low Voltage Power & Insulated Case Circuit Breakers Section 8
Power Break II Circuit Breakers
Power + Trip Unit Features

Power+ Trip Unit Systems Trip Target Module (Optional)


The Power+ trip unit system for Power Break II insulated case View Button: Press the VIEW button to check the trip unit status.
breakers consist of the trip unit, the trip actuator, current sensors Reset Button: Press the RESET button to clear any target that is set.
and rating plugs. The term trip unit system applies to the combi-
Battery check: Target modules use two standard, 3V, 16mm x
nation of these four components which form the solid-state
1.6mm, lithium batteries for viewing target information. Battery life
circuit breaker tripping system.
depends upon use, but may be estimated at one year. When the
Power+ trip units provide a complete range of standard and batteries are energized, depressing the VIEW button will illuminate
optional overcurrent and ground-fault protective functions. either a set target LED, i.e., LT or the BAT LED. Once target indicators
True RMS Sensing are cleared, battery status is indicated by the BAT LED. Replacement
The Power+ trip unit continues to batteries include Panasonic CR1616, Eveready E-CR1616BP, or
use GEs proven technique of Duracell DL1616B, which may be purchased commercially.
measuring true rms currents of Long-time pickup: The long-time pickup indicator moves through
both sinusoidal and harmonically two transitions. As the current in any phase reaches 95% of its
distorted waveforms. The frequent setpoint; the LTPU LED begins to flash. As current increases, flash-
sampling (48 times per cycle per ing frequency increases, until 100% of the pickup point is reached.
phase) allows precise calculations At that moment, the LTPU LED stays on continuously until the long-
of true rms current. The sampling time delay times out. Once the breaker has tripped on long-time,
rate allows waveform measure- the Overload target will be stored in memory. To view the trip, press
ments up to the 11th harmonic. the VIEW button. To clear the target, press the RESET button.
GEs true rms sensing avoids Short-time and instantaneous trips: Short-time and instantaneous
potential underprotection or over- trips share the same trip target. The LTPU LED is not illuminated,
protection problems associated since the time intervals between pickup and tripping are too short
with peak-sensing tripping systems. for either function. Once the breaker has tripped on short-time or
instantaneous, the short target will be stored in memory. To view the
trip, press the VIEW button. To clear the target, press the RESET button.
Accessory Integration
Ground fault trip (Target02 only): The trip target for a ground
Four accessories are integrated through the Power+ trip unit.
fault trip is the GF LED. To view the trip, press the view button. To
Drop-in shunt trip (with or without lockout), bell alarms (with or
clear the target, press the RESET button.
without lockout) and the undervoltage release modules fit into
keyed pockets. They operate through the trip units, and not Health monitor: Trip unit health status okay is illustrated by
through any external mechanisms. All accessory wiring is pre- slow blinking of the LTPU LED. It may be seen by depressing and
wired to secondary terminals, and no user wiring is necessary. holding the VIEW button. Sufficient power must be supplied to the
When activated, the shunt trip (with or without lockout) and trip unit via external test kit, power pack, or current transformers
undervoltage release modules send a signal to the trip unit to for the health monitor to be operational.
energize the trip actuator and open the breaker.
Standard and Optional Protective Functions
Standard and optional protective functions are available for
Power+ trip units. The breaker settings are programmed in multi-
ples of X (rating plug ampere values), S (current sensor ampere
rating values), and C (the long-time setting in amperesmultiply
long-time setting by rating plug ampere rating).

Standard
Adjustable Long-Time (L) Pickup, 0.5 - 1.0X, with four delay bands.
Adjustable Instantaneous (I) Pickup, 1.5 - 15X.

Options
Overload, Short Circuit, and Short-Time local trip indicators with
overload pickup warning and health monitor.
Adjustable Short-Time (S) Pickup, 1.5 - 9.0C, and delay (3 bands)
with I2t ON/OFF selection.
Adjustable Ground Fault (G) Pickup, 0.2 - 0.6S, and delay1
Power+ Trip Target Module (3 bands) with I2t ON/OFF selection and trip indicator.
Upgradeable Ground Fault function with use of appropriate
ground fault rating plug.
1Limited by breaker frame size above 2000A.

8-94 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Low Voltage Power & Insulated Case Circuit Breakers Section 8
Power Break II Circuit Breakers
Enhanced MicroVersaTrip Trip Unit Features

Enhanced MicroVersaTrip Trip Units


Enhanced MicroVersaTrip Plus and MicroVersaTrip PM trip units
give you two new ways to monitor and control the Power Break II
breaker with unprecedented ease. Through the simple keypad,
the trip unit lets you program and display a variety of functions
including tripping characteristics, remote communications, status

6 9 AV R D E E Y S R I P
information and protective relaying, and allows integration with

S
GE POWER LEADER Power Management Systems. The trip unit

R AB MV E TE EN TU
display also allows viewing of many standard metering parame-
ters as well as pickup alarms, trip target indications and fault
status information.

F O I L D P L W H TA
Enhanced MicroVersaTrip Plus and MicroVersaTrip PM trip

8- E TU S E T C T
units continue to use GEs proven technique of measuring true

E R C I L A A
rms currents (and voltages for MicroVersaTrip PM trip units) of

E T E. T .
both sinusoidal and harmonically distorted waveforms. The fre-

LS EE P
G S A FA R Y S O E G R S

D L T D
quent sampling (64 times per cycle) allows precise calculations of Enhanced MicroVersaTrip Plus and MicroVersaTrip PM Trip
Units have been specifically designed to integrate with the

AI S RI
true rms current. The sampling rate allows waveform measure-
ments up to the 31st harmonic to achieve accuracies of 99%. extensive capabilities offered by Power Break II circuit breakers.
PA I T U O B L V E
GEs true rms sensing avoids potential underprotection or over-
protection problems associated with peak-sensing tripping systems.
The enhanced trip unit design includes a wide range of functions
N N T O N O

and adds many new features:


U A EN BE S I CR

.
UL Listed Field-Interchangeable Features exclusive to MicroVersaTrip PM Trip Units
I

Non-volatile trip targets display/Cold setup capability Communications


RE N LL I M

Replaceable long-life batteries provide trip target indications All information can be viewed on the LCD display or
and cold setup capabilitywithout the need for external communicated over a POWER LEADER Power
E
power or a battery pack. Management System network.
:
W U E

Trip operations counter


T

Demand/peak demand
The number of long-time, short-time, instantaneous and The trip unit can display a rolling average of power demand
I P OT

ground fault trips are individually counted and displayed. and peak power demand at user-selected intervals from 5 to
A
N

Trip information 60 minutes.


On overcurrent faults, the trip unit displays fault pickup, the Local and remote metering
TR N

type of fault, the magnitude of the fault current and the Amps, volts, frequency
phase the fault occurred on. Real power, total power
Display indicates when a shunt trip or undervoltage release Accumulated energy
trip has opened the breaker. Protective relays include:
I

New display Current and voltage unbalance


V

Ergonomic, 5-button keypad Overvoltage


New targets with international symbols Undervoltage
High-resolution LCD display for local 3-phase ammetering Power reversal
I

New status and setup displays for greater ease of use Power reversal direction setup
M

True rms sensing for accurate response to high harmonic


content waveforms for Long-Time, Short-Time, and Ground
Fault protection.
50/60 Hz operation.
Interchangeable, UL Listed trip units and rating plugs with test
set jack for TVRMS2 test set.
EMI immunity per ANSI C37.90.

Rev. 11/13 www.geindustrial.com BuyLog Catalog 8-95


Data subject to change
without notice
Low Voltage Power & Insulated Case Circuit Breakers Section 8
Power Break II Circuit Breakers
Trip Unit Characteristics

EntelliGuard TU Trip Unit Characteristics


Long Time Short Time
Frame Max. Sensor Current Setting (C ) (Pick-Up)
Envelope Ampere Rating Multiple of Rating Delay2 (Seconds) Pick-up (Multiple
Size Rating (Amperes) (S) Plug Amperes (X) Thermal Type (C-Bands) Fuse Type (F-Bands) of Current Settings (C) Delay (Seconds)

800 800 200, 400, 800 0.20 0.025 I2T in1


0.60 0.025 Minimum - .046
1.21 0.025 Intermediate- .186
1.61 0.032 Maximum - .418
1600 1600 800, 1000, 1600 2.41 0.044
0.5 thru 1.0 in 3.21 0.059
Increments of 0.05 4.02 0.078
4.82 0.100 1.5 thru 9.0 in
2000 2000 2000 5.62 0.130 Increments of 0.5
6.43 0.170
7.23 0.220 I2T out2
2500 1000, 2000, 2500 8.04 0.270 .025, .033, .042, .058,
9.64 0.350 .092, .117, .158, .183,
3000 11.20 0.440 .217, .350, .417
3000 3000 12.90 0.550
14.50 0.690
16.10 0.870
4000 4000 4000 17.70 1.100
19.30

Trip Unit Characteristics (continued)


Ground Fault
Adjustable Instantaneous Adjustable Instantaneous
Pick-Up without ST Pick-Up with ST Pick-Up (Multiple
Envelope (Multiple of Rating (Multiple of Rating of Sensor Ampere Delay with I2T Slope Fixed
Size Plug Amperes) (X) Plug Amperes) (X) RELT without ST RELT with ST Rating) in Seconds Bands Delay
0.058
0.092
2.0 thru 10.0 in 2.0 thru 15.0 in 1.5 thru 10.0 in 1.5 thru 15.0 in 0.20 thru 0.60 in 0.117
800
0.5 increments 0.5 increments 0.5 increments 0.5 increments increments of 0.01 I2t - .385 0.158
2.0 thru 10.0 in 2.0 thru 15.0 in 1.5 thru 10.0 in 1.5 thru 15.0 in 0.20 thru 0.60 in 0.183
1600
0.5 increments 0.5 increments 0.5 increments 0.5 increments increments of 0.01 I4T - .179 0.217
.44 at 200% of
2.0 thru 10.0 in 2.0 thru 15.0 in 1.5 thru 10.0 in 1.5 thru 13.0 in 0.20 thru 0.60 in pick-up at lower 0.350
2000
0.5 increments 0.5 increments 0.5 increments 0.5 increments increments of 0.01 SGF - .553 0.417
level of band
3000 2.0 thru 10.0 in 2.0 thru 13.0 in 1.5 thru 10.0 in 1.5 thru 13.0 in 0.20 thru 0.37 in 0.517
0.5 increments 0.5 increments 0.5 increments 0.5 increments increments of 0.01 0.617
2.0 thru 9.0 in 2.0 thru 9.0 in 1.5 thru 9.0 in 1.5 thru 9.0 in 0.20 thru 0.30 in 0.717
4000
0.5 increments 0.5 increments 0.5 increments 0.5 increments increments of 0.01 0.817
0.917

Additional Features and Characteristics of the EntelliGuard TU Trip Unit


Trip Unit Character 9
Function Description 1 2 3 4 5 6 7 8 9 X A3 B3 C3 D3 E3
Metering
Communications Modbus Communications Bus Link
Amperes (A, kA)2 Selectable Phase Current 2.5%
Voltage (V) L-L or L-N Volts 1.5%
Energy (kWh,MWh,GWh) Total Energy Usage on Brkr 4%
Real Power (kW/MW) L-L or L-N Power 4%
Total Power ( kVA/MVA) L-L or L-N Power 4%
Frequency (Hz) Circuit Frequency 1Hz
Demand & Peak Demand (kW)
Relaying
Under Voltage Trip Adjustable pickup, 50-90%

Adjustable delay, 1-15 seconds OFF
Over Voltage Trip Adjustable pickup, 110-150%

Adjustable delay, 1-15 seconds OFF
Voltage Unbalance Adjustable pickup, 10-50%

Adjustable delay, 1-15 seconds OFF
Adjustable pickup, 10-990kW
Current Unbalance Adjustable delay, 1-15 seconds OFF
Power Reversal Direction
Data Acquisition - Waveform Capture
RELT
3Used when Ground Fault Alarm is needed via the output contact.

Additional Features and Characteristics of the EntelliGuard TU Trip Unit


Trip Unit Character 3 Zone Selective Interlocking Power Break II
Z ZSI, Short time and GF; user selectable
T Z + IOC ZSI; user selectable 1
X NONE SELECTED
1Instantaneous out only. 2Time delay shown at lower limit of each band. All pick-up tolerances are 10%.

8-96 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Low Voltage Power & Insulated Case Circuit Breakers Section 8
Power Break II Circuit Breakers
Trip Unit Characteristics

Power+ Trip Unit Characteristics


Long-Time Short-Time
Envelope Frame Max. Sensor Rating Current Setting (C) (Pick-Up) Pick-up (Multiple
Size Ampere Rating (Amperes) (S) Multiple of Rating Plug Amperes (X) Delay1 (Seconds 4 Bands) of Current Setting) (C) Delay (Seconds 3 Bands)
800 200, 400, 800
I2T in1
2000 1600 800, 1000, 1600 .10, .21, .35
0.5, 0.6, 0.7, 2.4, 4.9, 9.8, 20 1.5, 2.0, 2.5, 3.0,
2000 2000 0.8, 0.9, 0.95 and 1.0 4.0, 5.0, 7.0, and 9.0
3000 2500, 3000 1000, 2000, 2500, 3000 I2T out 2
.10, .21, .35
4000 4000 4000

Power+ Trip Unit Characteristics (continued)


Ground Fault
Adjustable Instantaneous Pick-Up without ST Adjustable Instantaneous Pick-Up with ST Pick-Up (Multiple of
Envelope Size (Multiple of Rating Plug Amperes) (X) (Multiple of Rating Plug Amperes) (X) Sensor Ampere Rating) Delay3 (Seconds 3 Bands)
1.5 thru 10.0 1.5 thru 15.0 0.20 thru 0.60
I 2 T in 4
2000 1.5 thru 10.0 1.5 thru 15.0 0.20 thru 0.60 .10, .21, .35
1.5 thru 10.0 1.5 thru 15.0 0.20 thru 0.60
3000 1.5 thru 10.0 1.5 thru 13.0 0.20 thru 0.37 I 2 T out 2
.10, .21, .35
4000 1.5 thru 9.0 1.5 thru 9.0 0.20 thru 0.30

Enhanced MicroVersaTrip Plus and PM Trip Unit Characteristics


Long-Time Short-Time
Frame Max. Sensor Rating Current Setting (C) (Pick-Up) Pick-up (Multiple of
Envelope Size Ampere Rating (Amperes) (S) Multiple of Rating Plug Amperes (X) Delay2 (Seconds) Current Setting) (C) Delay (Seconds)
800 800 200, 400, 800
1600 1600 800, 1000, 1600 I 2 T in1
0.40
2000 2000 2000 0.5 thru 1.0 in 1.5 thru 9.0 in
increments of 0.05 2.4, 4.9, 9.8, 20 increments of 0.5
2500 1000, 2000, 2500
3000 I 2 T out 2
3000 3000
.10, .21, .35
4000 4000 4000

Trip Unit Characteristics (continued)


Ground Fault
Adjustable Instantaneous Adjustable Instantaneous High Range Instantaneous
Pick-Up without ST (Multiple Pick-Up with ST (Multiple (Multiple of Frame Pick-Up (Multiple Delay With l2T Delay3 With l2T
Envelope Size of Rating Plug Amperes) (X) of Rating Plug Amperes) (X) Short-Time Rating) (H) of Sensor Ampere Rating) In Seconds Out Seconds

800 1.5 thru 10.0 in 1.5 thru 15.0 in 0.20 thru 0.60 in
0.5 increments 0.5 increments increments of 0.01

1600 1.5 thru 10.0 in 1.5 thru 15.0 in 0.20 thru 0.60 in
0.5 increments 0.5 increments increments of 0.01
.44 at 200% of
2000 1.5 thru 10.0 in 1.5 thru 15.0 in 1.0 0.20 thru 0.60 in .10, .21, .35
pick-up at lower
0.5 increments 0.5 increments increments of 0.01
limit of band
3000 1.5 thru 10.0 in 1.5 thru 13.0 in 0.20 thru 0.37 in
0.5 increments 0.5 increments increments of 0.01

4000 1.5 thru 9.0 in 1.5 thru 9.0 in 0.20 thru 0.30 in
0.5 increments 0.5 increments increments of 0.01

1 Time delay shown at 600% of current setting at lower limit of band. X = Rating plug amps
2 Time delay shown at lower limit of each band. All pick-up tolerances are 10%. S = Sensor amp rating
3 Time delay shown at lower limit of each band. Ground fault pick-up not to exceed 1200 amperes. C = Long-time current setting (pick-up)
4 Time delay shown at 200% of pick-up at lower limit of band. H = Short-Time Rating

Rev. 11/13 www.geindustrial.com BuyLog Catalog 8-97


Data subject to change
without notice
Low Voltage Power & Insulated Case Circuit Breakers Section 8
Power Break II Circuit Breakers
Trip Unit Characteristics (continued)

Additional Features and Characteristics Exclusive to the Enhanced MicroVersaTrip PM Trip Unit1
Trip Unit Suffix
Function Description M (Metering) P (Relaying) PM (Metering & Relaying)

Communications POWER LEADER Communications Bus Link STD STD STD


Amperes (A, kA) 2 Selectable Phase Current 2.5% STD STD STD
Voltage (V) L-L or L-N Volts 1.5%
Energy (kWh, MWh, GWh) Total Energy Usage on Brkr 4%
Real Power (kW/MW) L-L or L-N Power 4%
Total Power (kVA/MVA) L-L or L-N Power 4%
Frequency (Hz) Circuit Frequency 1Hz
Demand & Peak Demand (kW)
Adjustable pickup 50-90%
Under Voltage Trip
Adjustable delay, 1-15 seconds OFF
Adjustable pickup, 110-150%
Over Voltage Trip
Adjustable delay, 1-15 seconds OFF
Adjustable pickup, 10-50%
Voltage Unbalance Adjustable delay, 1-15 seconds OFF

Adjustable pickup, 10-50%


Current Unbalance
Adjustable delay, 1-15 seconds OFF
Adjustable pickup, 10-990 kW
Power Reversal Adjustable delay, 1-15 seconds OFF
Power Reversal Direction

1 MicroVersaTrip PM functions require 24 Vdc control power.


2 Ampere reading also standard on MicroVersaTrip Plus trip units.

8-98 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Low Voltage Power & Insulated Case Circuit Breakers Section 8
Power Break II Circuit Breakers
Power Break II Nomenclature System

How to Select Power Break II

S S D 2 G 5 X 2 U 4 1 0 0 0 H
Step 1 Step 2 Step 3 Step 4 Step 5 Step 6 Step 7 Step 8 Step 9 Step 10 Step 11 Step 12 Step 13 Step 14 Step 15

Circuit Auxiliary Switch,


Breaker Stationary/
S = Power Drawout,
Break II Trimplate
H = 4-240V,
Drawout, None
Interrupting Capacity
S = Standard Closing Solenoid,
Door Interlock, Counter
Construction 0 = None, None , None
D = Drawout
Electric Operator, Push
Button Cover, Hidden On
Frame
0 = None, None , None
2 = 1600 A

Undervoltage Release, Racking Padlock


Trip Unit
0 = None, None
G = EntelliGuard TU

Bell Alarm, Bell Alarm with Lock Out,


Current Sensor Kirk Key Protection
5 = 1600 A
1 = None, 240, None

Metering, RELT, Communication, Relays, ZSI Shunt Trip


X = Metering- Current , Communication- None, Relays- None , ZSI- None 4 = 120 VAC/125 VDC

Overcurrent Protection Package Trip Unit Rating Plug


2 = LSI U = 1600

Step 1 Circuit Breaker (Example) Step 5 Trip Unit (Example)


Breaker Type Character 1 Trip Unit Type Character 5
Power Break II S Power + D
Enhanced MVT B
Enhanced MVT PM C
EntelliGuard TU G
Step 2 Interrupting Capacity (Example) Switch w/PP Y
Interrupting Type Character 2
Standard S
High Break H Step 6 Current Sensor (Example)
Sensor Rating Character 6
Step 3 Construction (Example) 200A 1
400A 2
Construction Type Character 3
800A 3
Stationary Front Connected F
1000A 4
Stationary Back Connected B
1600A 5
Drawout D
2000A 6
2500A 7
3000A 8
Step 4 Frame Ratings 4000A 9
Frame Rating Character 4
800A 1
1600A 2
2000A 3
2500A 4
3000A 5
4000A 6

Rev. 11/13 www.geindustrial.com BuyLog Catalog 8-99


Data subject to change
without notice
Low Voltage Power & Insulated Case Circuit Breakers Section 8
Power Break II Circuit Breakers
Power Break II Nomenclature System

Step 7 Metering, RELT, Communication, Relays, ZSI (Example)


Trip Unit Type + Features Character 7

POWER + X

Metering None

Communication None

Relays None

ZSI None

ENHANCED MVT X A B

Metering Current Current Current

Communication None None None

Relays None None None

ZSI None GF GF&ST

ENHANCED MVT PM C D E F G H J K L

Metering Current Current Current Full Full Full Full Full Full

Communication COMNET COMNET COMNET COMNET COMNET COMNET COMNET COMNET COMNET

Relays P P P None None None P P P

ZSI None GF GF&ST None GF GF&ST None GF GF&ST

ENTELLIGUARD TU X A B C D E F G H J K L M N

Metering Current Current Current Current1 Full Full1 Full Full1 Current Current Current Current1

RELT None RELT RELT None1 RELT None1 RELT None1 None RELT RELT None1

Communication None None Modbus Modbus1 Modbus Modbus1 Modbus Modbus1 None None Modbus Modbus1

Relays None None None None1 None None1 YES YES1 None None None None1

ZSI None None None None1 None None1 None None1 GF&ST GF&ST GF&ST GF&ST1

Trip Unit Type + Features Character 7 (continued)

ENTELLIGUARD TU P Q R V W Y Z 1 2 3 4 5 6 7 8 9

Metering Full Full1 Full Full1 Current1 Current1 Current1 Current1 Full1 Full1 Full1 Full1

RELT RELT None1 RELT None1 None1 RELT1 RELT1 None1 RELT1 None1 RELT1 None1

Communication Modbus Modbus1 Modbus Modbus1 None1 None1 Modbus1 Modbus1 Modbus1 Modbus1 Modbus1 Modbus1

Relays None None1 YES YES1 None1 None1 None1 None1 None1 None1 YES1 YES1

ZSI GF&ST GF&ST1 GF&ST GF&ST1 GFST&I1 GFST&I1 GFST&I1 GFST&I1 GFST&I1 GFST&I1 GFST&I1 GFST&I1
1 Zone Selective Intantaneous Ground Fault & Short Time & Instantaneous (out)

Step 8 Overcurrent Protection Package (Example)


Character 8 Package Character 8 Package
X None (switch) 7 LSHG
1 LI 8 LIG
2 LSI2 9 LIGA
3 LSIG2 A LIGD
4 LSIGA2 B LSHGA
5 LSIGD2 C LSHGD
6 LSH D LSIH
2EntelliGuard TU Trip Unit only offers these

8-100 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Low Voltage Power & Insulated Case Circuit Breakers Section 8
Power Break II Circuit Breakers
Power Break II Nomenclature System

Step 9 Trip Unit Rating Plug (Example)


MicroVersaTrip Plus and
Character EntelliGuard TU Enhanced MicroVersaTrip
9 Trip Unit PM Trip Unit Power + Rating Plug Availability by Current Sensor Rating (shaded areas indicate availability)

X X 200 400 800 1000 1600 2000 2500 3000 4000

A 100

B 150 1

C 200

D 225

E 250

F 300 1

G 350 2 2 2 2 2 2 2 2 2

H 400 1

I 450

J 500

K 600 1

L 700

M 750 1

N 800 1

O 900 2 2 2 2 2 2 2 2 2

P 1000

Q 1100

R 1200 1

S 1250 2 2 2 2 2 2 2 2 2

T 1500

U 1600

V 1900 2 2 2 2 2 2 2 2 2

W 2000

Y 2200 2 2 2 2 2 2 2 2 2

Z 2400 2 2 2 2 2 2 2 2 2

1 2500

2 3000

3 3200 2 2 2 2 2 2 2 2 2

4 3600

5 4000
1Exclusive for MicroVersaTrip Plus and Enhanced MicroVersaTrip PM Trip Unit Rating Plugs
2Exclusive for EntelliGuard TU Trip Unit Rating Plugs only Step 11 Bell Alarm, Bell Alarm With Lockout, Kirk Key Provision
(Example)
Character 11 Bell Alarm Bell Alarm w/Lockout3 Kirk Key Provision4
Step 10 Shunt Trip (Example) 0 None None None
Character 10 Voltage With Lockout Without Lockout 1 None 240 None
0 None 2 None 600 None
1 12Vdc 4 240 None None
2 24Vac/24Vdc 5 240 240 None
3 48Vac/48Vdc 6 240 600 None
4 120Vac/125Vdc 8 600 None None
5 208Vac 9 600 240 None
6 240Vac/250Vdc A 600 600 None
7 480Vac G None None 4
8 600Vac H None 240 4
H 12Vdc J None 600 4
J 24Vac/24Vdc L 240 None 4
K 48Vac/48Vdc M 240 240 4
L 120Vac/125Vdc N 240 600 4
M 208Vac R 600 None 4
N 240Vac/250Vdc S 600 240 4
P 480Vac T 600 600 4
R 600Vac 3Bell Alarm ratings Vac

4Kirk Key Provision number of key locks 1-4

Note: 600Vac module not UL Listed.

Rev. 11/13 www.geindustrial.com BuyLog Catalog 8-101


Data subject to change
without notice
Low Voltage Power & Insulated Case Circuit Breakers Section 8
Power Break II Circuit Breakers
Power Break II Nomenclature System

Step 12 UnderVoltage Release, Racking Padlock Step 13 Electric Operator, Push Button Cover, Hidden On
(Example) (Example)
Character 12 UnderVoltage Release Racking Padlock1 Character 13 Electric Operator Push Button Cover Hidden On
0 None None 0 None None None
1 24Vac None 1 120Vac None None
2 48Vac None 2 240Vac None None
3 120Vac None 3 24Vdc None None
4 208Vac None 4 48Vdc None None
5 240Vac None 5 72Vdc None None
6 480Vac None 6 125Vdc None None
7 600Vac None 8 None YES None
8 12Vdc None 9 120Vac YES None
9 24Vdc None A 240Vac YES None
A 48Vdc None B 24Vdc YES None
B 125Vdc None C 48Vdc YES None
C 250Vdc None D 72Vdc YES None
G None All E 125Vdc YES None
H 24Vac All G None None YES
J 48Vac All H 120Vac None YES
K 120Vac All J 240Vac None YES
L 208Vac All K 24Vdc None YES
M 240Vac All L 48Vdc None YES
N 480Vac All M 72Vdc None YES
P 600Vac All N 125Vdc None YES
R 12Vdc All R None YES YES
S 24Vdc All S 120Vac YES YES
T 48Vdc All T 240Vac YES YES
U 125Vdc All U 24Vdc YES YES
V 250Vdc All V 48Vdc YES YES
1Frame Rating W 72Vdc YES YES
X 125Vdc YES YES

Step 14 Closing Solenoid, Door Interlock, Counter Step 15 Auxiliary Switch, Stationary/Draw-out, Trimplate
(Example) (Example)
Character 14 Closing Solenoid Door Interlock Counter Character 15 Auxiliary Switch Stationary/Draw-out Trimplate
0 None None None 0 None Stationary None
1 120Vac None None 1 4-240V Stationary None
2 240Vac None None 2 8-240V Stationary None
3 24Vdc None None 3 12-240V Stationary None
4 48Vdc None None 4 4-600V Stationary None
5 72Vdc None None 5 8-600V Stationary None
6 125Vdc None None 8 None Stationary YES
8 None YES None 9 4-240V Stationary YES
9 120Vac YES None A 8-240V Stationary YES
A 240Vac YES None B 12-240V Stationary YES
B 24Vdc YES None C 4-600V Stationary YES
C 48Vdc YES None D 8-600V Stationary YES
D 72Vdc YES None H 4-240V Drawout None
E 125Vdc YES None J 8-240V Drawout None
G None None YES K 12-240V Drawout None
H 120Vac None YES L 4-600V Drawout None
J 240Vac None YES M 8-600V Drawout None
K 24Vdc None YES S 4-240V Drawout YES
L 48Vdc None YES T 8-240V Drawout YES
M 72Vdc None YES U 12-240V Drawout YES
N 125Vdc None YES V 4-600V Drawout YES
R None YES YES W 8-600V Drawout YES
S 120Vac YES YES
T 240Vac YES YES
U 24Vdc YES YES
V 48Vdc YES YES
W 72Vdc YES YES
X 125Vdc YES YES

8-102 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Low Voltage Power & Insulated Case Circuit Breakers Section 8
Power Break II Circuit Breakers
Power Break II Nomenclature System

Power Break II Circuit Breaker Frame Product Numbers

S S D 08 * 02 H1
Power Break II Breaker Type

Current Interrupting Capacity Auxiliary Function


S = Standard break H = High-range instantaneous current sensors
H = Hi-Break breaker Blank = Standard current sensors

Current Sensor Rating


Construction
02 = 200 A 20 = 2000 A
D = Drawout
04 = 400 A 25 = 2500 A
F = Stationary, front connected
08 = 800 A 30 = 3000 A
B = Back connected, 2500 3000 A only
10 = 1000 A 40 = 4000 A
16 = 1600 A
Frame Rating
08 = 800 A 25 = 2500 A Trip Unit Type and Rating
16 = 1600 A 30 = 3000 A B2/D2 = 2000 A maximum
20 = 2000 A 40 = 4000 A B3/D3 = 2500 A, 3000 A
B4/D4 = 4000 A
Y = Insulated case switch
B for Enhanced MicroVersaTrip Plus and MicroVersaTrip PM trip unit
D for Power+

1High-range instantaneous sensors only available on MicroVersaTrip Plus and MicroVersaTrip PM units.
NOTE: This information is provided only for use interpreting product numbers. It cannot be used to build product numbers.

Accessory Product Numbers

SP AS 240 AB4D R
Power Break II Breaker Extender
R = Field installable kit
Device Type
Blank = Factory installed
AS = Auxiliary switch2
BAA = Bell alarm, alarm only2 Auxiliary Switch Extender
BAL = Bell alarm with lockout2 AB4 = Auxiliary switch, type AB with 4 elements
COUNTER = Mechanical counter2 AB8 = Auxiliary switch, type AB with 8 elements
DIL = Defeatable door interlock AB12 = Auxiliary switch, type AB with 12 elements
DOSD = Drawout secondary disconnects (add suffix D for Drawout construction)
DOWB = Drawout mechanical interlock
DSS = Substructure shutter kit
E = Electric operator2 Voltage, unless otherwise stated
HDOS = Hi-Break rated drawout substructure 012 = 12 Vdc
K4 = Kirk key lock (4 maximum)2 024 = 24 Vdc
PBCOVER = Pushbutton cover2 048 = 48 Vdc
RCS = Remote close solenoid2 120/125 = 120 Vac or 125 Vdc
SDOD = Standard rated drawout substructure 240/250 = 240 Vac and 250 Vdc
ST = Shunt trip2 250 = 250 Vdc
STL = Shunt trip with lockout2 480 = 480 Vac
UV = Undervoltage release 600 = 600 Vac
WB = Walking beam for stationery breakers 08 = 800 A 25 = 2500 A
08 = 800A T-stud 16 = 1600 A 30 = 3000 A
20 = 1600 thru 2000A T-stud 20 = 2000 A 40 = 4000 A
S20 = 2000A T-stud (3000 frame) BCA = Back connected aluminum
S25 = 2500A T-stud BCC = Back connected copper
S30 = 3000A T-stud FCA = Front connected aluminum terminal T-stud
S40 = 4000A T-stud FCA = Front connected copper terminal T-stud
RAILS = Rail kit LFCC = Front connected copper, long stud
LUGA = Lug adapter kit 36B = 36 secondary disconnects, breaker
B = Enclosure 36C = 36 secondary disconnects, substructure

2Device Product Number requires an extender R for field installable kit version only.
NOTE: This information is provided only for use interpreting product numbers. It cannot be used to build product numbers.

Rev. 11/13 www.geindustrial.com BuyLog Catalog 8-103


Data subject to change
without notice
Low Voltage Power & Insulated Case Circuit Breakers Section 8
Power Break II Circuit Breakers
Product Number Nomenclature System

Entelliguard TU Trip Unit Product Numbers

G B 2 0 4 L 5 C 5 X R X X X X
Step 1 Step 2 Step 3 Step 4 Step 5 Step 6 Step 7 Step 8 Reserved Reserved Reserved Reserved

Trip Unit
Form Reserved
Power
Break II

Frame Ratings Reserved


1600A

Sensor Rating Reserved


400A

OC and GF Protection Packages Reserved


LSIGA (S, switchable) (I, switchable ANSI only)

Zone Selective Interlocking Original or Replacement Trip Unit


ZSI, Short time and GF; user selectable Replacement

Advanced Features and Communications Manual / Auto Trip Reset


Monitoring + Relay Package + RELT Not Selected

Step 1 EntelliGuard Trip Unit Form Step 2 Frame Ratings


Character 1 & 2 Trip Unit Form Character 3 Frame Rating (amperes) PowerBreak I / II
GA PB1 (UL) 1 800A
GB PB2 (UL) 2 1600A
3 2000A
4 2500A
5 3000A
6 3200A
7 4000A

Step 3 Sensor Rating (Amperes) Step 4 OC and GF Protection Packages


Character 4 & 5 Sensor Rating (Amperes) Character 6 & 7 Protection PowerBreak I / II
02 200 L3 LSI (S, switchable) (I, Non-switchable)
04 400 LSIG (S, switchable) (I, Non-switchable)
L4
08 800 (G, Non-Switchable Ground Fault Trip)
10 1000 LSIGA (S, switchable) (I, Non-switchable)
L5
12 1200 (G, Non-Switchable Ground Fault Alarm)
14 LSIC (S, switchable) (I, Non-switchable)
L6
15 (C, Non-Switchable External Ground Fault Trip)
16 1600 LSICA (S, switchable) (I, Non-switchable)
L7
20 2000 (C, Non-Switchable External Ground Fault Alarm)
25 2500 L8 LSIGDA* (S, G, A all switchable) (I, Non-switchable)
30 3000 L9 LSIGCDA* (S, G, C, A all switchable) (I, Non-switchable)
NOTE: All options include both the Circuit Break I2T and Fuse I4T curves

8-104 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Low Voltage Power & Insulated Case Circuit Breakers Section 8
Power Break II Circuit Breakers
Product Number Nomenclature System

Step 5 Zone Selective Interlocking Step 6 Advanced Features and Communications


Character 8 Zone Selective Interlocking PowerBreak II Character 9 Features and Communications PowerBreak II
Z ZSI, Short time and GF; user selectable 1 RELT
T Z + IOC ZSI; user selectable 1 2 Modbus Protocol + RELT
X NONE SELECTED 4 Monitoring + RELT
1Instantaneous 5 Monitoring + Relay Package + RELT
out only (used as a feeder).
6 Monitoring + Data Acquisition, Modbus Protocol + RELT
X NONE SELECTED
A2 Modbus Protocol (W/O RELT)
B2 Monitoring (W/O RELT)
C2 Monitoring + Relay Package (W/O RELT)
D2 Monitoring + Data Acquisition, Modbus Protocol (W/O RELT)
Monitoring + Data Acquisition + Relay Package,
E2
Modbus (W/O RELT)
2Options A - E are only available when output contact is needed for functions other
than RELT

Step 7 Manual/Auto Trip Reset Step 8 Original or Replacement Trip Unit


Character 10 Manual/Auto Trip Reset PowerBreak II Character 11-15 Original or Replacement Trip Unit
X NONE SELECTED3 RXXXX Replacement trip unit (shipped loose)
3Feature not available for legacy breakers

EntelliGuard TU Trip Unit Rating Plug Product Numbers

GTP 1100 U 12 25
Trip Unit Type Rating Largest Current Sensor Rating
GTP = Trip unit rating plug 01 = 150 A 16 = 1600 A
EntelliGuard TU Trip Unit 02 = 200 A 20 = 2000 A
03 = 225 A 25 = 2500 A
Rating Plug Ampere Rating
04 = 400 A 30 = 3000 A
0060 = 60 A 1000 = 1000 A
06 = 600 A 32 = 3200 A
0080 = 80 A 1100 = 1100 A
07 = 630 A 40 = 4000 A
0100 = 100 A 1200 = 1200 A
08 = 800 A 50 = 5000 A
0125 = 125 A 1500 = 1500 A
10 = 1000 A 60 = 6000 A
0150 = 150 A 1600 = 1600 A
12 = 1200 A 64 = 6400 A
0200 = 200 A 1700 = 1700 A
13 = 1250 A
0225 = 225 A 1800 = 1800 A
0250 = 250 A 1900 = 1900 A Smallest Current Sensor Rating
0300 = 300 A 2000 = 2000 A 01 = 150 A 16 = 1600 A
0350 = 350 A 2200 = 2200 A 02 = 200 A 20 = 2000 A
0400 = 400 A 2400 = 2400 A 03 = 225 A 25 = 2500 A
0450 = 450 A 2500 = 2500 A 04 = 400 A 30 = 3000 A
0500 = 500 A 3000 = 3000 A 06 = 600 A 32 = 3200 A
0600 = 600 A 3200 = 3200 A 07 = 630 A 40 = 4000 A
0700 = 700 A 3600 = 3600 A 08 = 800 A 50 = 5000 A
0750 = 750 A 4000 = 4000 A 10 = 1000 A 60 = 6000 A
0800 = 800 A 5000 = 5000 A 12 = 1200 A 64 = 6400 A
0900 = 900 A 6000 = 6000 A 13 = 1250 A
Trip Unit Type
U = Universal Trip Plug

Rev. 11/13 www.geindustrial.com BuyLog Catalog 8-105


Data subject to change
without notice
Low Voltage Power & Insulated Case Circuit Breakers Section 8
Power Break II Circuit Breakers
Product Number Nomenclature System

Power+ Trip Unit Product Numbers

D2 20 LSI T1 R1
Trip Unit Type and Rating Replacement or New
D2 = Power Break II Power+ Trip Unit: R = Replacement trip unit
2000 A sensor maximum (Blank) = New
D3 = Power Break II Power+ Trip Unit:
3000 A sensor maximum
D4 = Power Break II Power+ Trip Unit: Trip unit options
4000 A sensor maximum T1 = Target Module without ground fault target
T2 = Target Module with ground fault target
(Blank) = Factory Installed
Current Sensor Rating
02 = 200 A 20 = 2000 A
04 = 400 A 25 = 2500 A
08 = 800 A 30 = 3000 A Auxiliary functions
10 = 1000 A 40 = 4000 A LI = Long-time and Instantaneous
16 = 1600 A LSI = Long-time, Short-time, Instantaneous

1Device Product Number requires an extender R for field installable kit version only.
NOTE: This information is provided only for use interpreting product numbers. It cannot be used to build product numbers.

Power+ Rating Plug Product Numbers

TR 10 C 800 GF
Trip Unit Type Rating Ground Fault Function
TR = Trip unit rating plug Blank = No ground fault
All Power+, MicroVersaTrip Plus, GF = Ground fault
and MicroVersaTrip PM
rating plugs
Rating Plug Ampere Rating
Current Sensor Rating 100 = 100 A 800 = 800 A
02 = 200 A 20 = 2000 A 150 = 150 A 1000 = 1000 A
04 = 400 A 25 = 2500 A 200 = 200 A 1100 = 1100 A
08 = 800 A 30 = 3000 A 225 = 225 A 1200 = 1200 A
10 = 1000 A 40 = 4000 A 250 = 250 A 1500 = 1500 A
16 = 1600 A 300 = 300 A 1600 = 1600 A
400 = 400 A 2000 = 2000 A
Trip Unit Type 450 = 450 A 2500 = 2500 A
C = Power+ trip unit rating plugs 500 = 500 A 3000 = 3000 A
600 = 600 A 3600 = 3600 A
700 = 700 A 4000 = 4000 A
Power+ Target Module Product Numbers
TARGET00 = Blank insert for Target Module
TARGET01 = Target Module without ground fault target
TARGET02 = Target Module with ground fault target

NOTE: This information is provided only for use interpreting product numbers. It cannot be used to build product numbers.

8-106 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Low Voltage Power & Insulated Case Circuit Breakers Section 8
Power Break II Circuit Breakers
Product Number Nomenclature System

MicroVersaTrip Plus and MicroVersaTrip PM Trip Unit Product Numbers

B2 20 LSI GZ1 PM R1
Trip Unit Type and Rating
B2 = Power Break II Enhanced
MicroVersaTrip Plus or PM Trip Unit:
2000 A Sensor maximum Remanufactured
B3 = Power Break II Enhanced RM = Remanufactured Trip Unit
MicroVersaTrip Plus or PM Trip Unit: RX = Exchanged Trip Unit
3000 A Sensor maximum
B4 = Power Break II Enhanced
MicroVersaTrip Plus or PM Trip Unit:
Trip Unit Options
4000 A Sensor maximum
Options for MicroVersaTrip PM trip units only. Must select one:
P = Protective relays & communications
Current Sensor Rating M = Metering & communications
02 = 200 A 20 = 2000 A PM = Protective relays, metering, & communications
04 = 400 A 25 = 2500 A (Blank) = MicroVersaTrip Plus trip unit
08 = 800 A 30 = 3000 A
10 = 1000 A 40 = 4000 A
16 = 1600 A
Ground Fault Functions
G = Ground fault
Auxiliary Functions GD = Ground fault defeatable (not UL listed)
LI = Long-time and instantaneous GZ1 = Ground fault; zone selective interlocking for ground fault only
LSI = Long-time, short-time, instantaneous GZ2 = Ground fault and short-time selective interlock
LSH = Long-time, short-time, high-range GDZ2 = Ground fault defeatable (not UL listed): ground fault and
instantaneous short-time selective interlock
(Blank) = None

1Device Product Number requires an extender R for field installable kit version only.
NOTE: This information is provided only for use interpreting product numbers. It cannot be used to build product numbers.

Rating Plug Product Numbers (MicroVersaTrip Plus and PM)

TR 10 B 800
Device Type
Rating Plug Ampere Rating
TR = Trip unit rating plug
100 = 100 A 1000 = 1000 A
All MicroVersaTrip Plus and
150 = 150 A 1200 = 1200 A
MicroVersaTrip PM rating plugs
200 = 200 A 1500 = 1500 A
225 = 225 A 1600 = 1600 A
300 = 300 A 2000 = 2000 A
Current Sensor Rating
400 = 400 A 2500 = 2500 A
2 = 200 A 20 = 2000 A
500 = 500 A 3000 = 3000 A
4 = 400 A 25 = 2500 A
600 = 600 A 3600 = 3600 A
8 = 800 A 30 = 3000 A
700 = 700 A 4000 = 4000 A
10 = 1000 A 40 = 4000 A
800 = 800 A
16 = 1600 A

Trip Unit Type


B = All Enhanced MicroVersaTrip Plus and MicroVersaTrip PM
trip unit rating plugs

NOTE: This information is provided only for use interpreting product numbers. It cannot be used to build product numbers.

Rev. 11/13 www.geindustrial.com BuyLog Catalog 8-107


Data subject to change
without notice
Low Voltage Power & Insulated Case Circuit Breakers Section 8
Power Break II Circuit Breakers
Interrupting Capacity and Withstand Ratings

The interruption ratings and voltages shown in the table are max-
imum ratings. A circuit breaker of the type given in the left-hand
column may be applied at the given circuit voltage in any electri-
cal distribution system where the available fault current at the
load terminals of the breaker does not exceed the value in the
table. That circuit breaker type may also be applied at intermedi-
ate values of circuit voltage provided the available fault current at
the load terminals of the breaker does not exceed the value in the
table for the higher value of voltage.

Power Break II Interrupting Capacity and


Short-time Ratingsrms Symmetrical kA

Frame 800A 1600 to 2000A 2500-3000A 4000A


UL 489 Ratings, 50/60 Hz Standard
240V 65 85 100 100
480V 65 65 100 100
600V 42 50 85 85
Hi-Break
240V 100 125 200 200
480V 100 100 150 150
600V 65 65 100 100
Short Time 1
(0.5 sec) 25 40 42 42
IEC-947-2 Ratings 415, 50/60 Hz
I CU 75 75 2 85
I CS 56 45 2 25
I CW (1 sec) 40 50 2 50
1 Applies to high range instantaneous or "H" option.
2 Must use 4000A construction.
Complete dimensions and weight information can be found in the Power Break II
application guide GET-8052.

Stationary and Draw-out Switch Withstand Ratingsrms Symmetrical kA


Maximum Short Circuit Withstand Rating Suitable on 200,000 rms Sym Ampere Fault Circuit
Short-time When Protected By Power Break II Circuit Breakers When Protected by Class L Fuses As Follows
Rating, rms
Switch Sym Amperes @ Breaker Standard Break Hi-Break Line Side Load Side
Frame 600 Vac Max., Frame Size PB II Circuit Breaker PB II Circuit Breaker Max. Fuse Max. Fuse
(Amperes) 500 ms Max. (Amperes) 240 Vac 480 Vac 600 Vac 240 Vac 480 Vac 600 Vac Ampere Rating Ampere Rating
800 30 800 65 65 50 100 100 65 2000 800
1600 40 1600 65 65 50 125 100 65 2500 1600
2000 40 2000 65 65 50 125 100 65 2500 2000
2500 42 2500 100 100 85 200 150 100 2500 2500
3000 42 3000 100 100 85 200 150 100 4000 3000
4000 42 4000 100 100 85 200 150 100 4000 4000

8-108 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Low Voltage Power & Insulated Case Circuit Breakers Section 8
Power Break II Circuit Breakers
How To Order

How To Order
Power Break IIs were previously ordered as separate product
numbers for the Frame, Trip Unit, Accessories, etc. In 2008, they
transitioned to a single 15 digit product number.
1. Determine your 15 digit number by using the BuyLog or the
digitized configurator.
2. Check Elitenet for price and availability. Note: Because the
number of possible combinations is in the millions, only product
numbers that have been ordered are in EliteNet. If the number
is not available in Elitenet, email the request to load the part to
GE.1STOP_REPLY@GE.com
3. Once the product number is loaded and pricing finalized, the
product can be ordered.
4. Note: Substructures/Cassettes, Neutral CTs, T-Studs, Drawout
Secondary disconnects are ordered separately from the 15 SSF20B220 Frame
digit number.

ExampleStationary Breaker SSF3G6H2N001130


2000 ampere stationary frame, 65 kA, 480 V IC rating, 2000
ampere sensor, 800 ampere rating plug, trip unit functions includ-
ing long-time (L), short-time (S), Instantaneous (I), EntelliGuard TU
trip unit, field installed 120 Vac electric (motor) operator, 24 Vdc
remote close solenoid, 24 Vdc undervoltage release module.

Note: See Power Break II Price Configurator, your GE Sales


Representative, or call 1-800-GE1-STOP for pricing or any other
information.

Draw-out in Substructure
ExampleDraw-out Breaker SHD2B4X6K200130
1600 ampere draw-out frame, 100 kA, 480 V IC rating, 1000 ampere
sensor, 600 ampere rating plug, trip unit functions including long-
time (L), short-time (S), high range instantaneous (H), factory installed
accessories including: 120 Vac electric (motor) operator; 24 Vdc
remote close solenoid; 24 Vdc shunt trip; draw-out substructure;
draw-out secondary disconnect; draw-out shutter.

Note: See Power Break II Price Configurator, your GE Sales


Representative, or call 1-800-GE1-STOP for pricing or any other
information.

Description Product Number


Drawout Substructure SPHDOS16
Substructure Secondary Disconnect SPDOSD36S
Substructure Shutter Kit SPDSS20

Rev. 11/13 www.geindustrial.com BuyLog Catalog 8-109


Data subject to change
without notice
Low Voltage Power & Insulated Case Circuit Breakers Section 8
Power Break II Circuit Breakers
Frame Selection (Old Structure)

R RE A NU E O II
Basic Frame SelectionStationary

PR K M N
FO B T R K

IN I R
Standard Break Hi-Break
Circuit Breaker Circuit Breaker
Envelope Size Frame Size Current Sensor Product Product

IC I BE
(Amperes) (Amperes) (Amperes) Number1 Number1

R E R U C AT U E A
200 SSF08*202,H SHF08*202,H
800 800 400 SSF08*204,H SHF08*204,H
800 SSF08*208,H SHF08*208,H
TO W O D C L B R
800 SSF16*208,H SHF16*208,H

.
G
1600 1600 1000 SSF16*210,H SHF16*210,H
1600 SSF16*216,H SHF16*216,H
U P P E R

2000 2000 2000 SSF20*220,H SHF20*220,H


SSF25*210,H SHF25*210,H
G E R M E

1000
SSB25*210,H SHB25*210,H
FI SE O O W

SSF25*220,H SHF25*220,H
2500 2000
RA O R N

SSB25*220,H SHB25*220,H
3000
PO

SSF25*325,H SHF25*325,H
2500
SSB25*325,H SHB25*325,H
SSF30*330,H SHF30*330,H
3000 3000
SSB30*330,H SHB30*330,H
CO N 9 ED EE

4000 4000 4000 SSF40*4403 SHF40*4403


N
S

Basic Frame SelectionDraw-out (without substructure)


. 8 DA E :

Standard Break Hi-Break


Circuit Breaker Circuit Breaker
Envelope Size Frame Size Current Sensor Product Product
(Amperes) (Amperes) (Amperes) Number1 Number1
P G U P OT

F
T

200 SSD08*202,H SHD08*202,H


800 800 400 SSD08*204,H SHD08*204,H
9
N

800 SSD08*208,H SHD08*208,H


800 SSD16*208,H SHD16*208,H
-

1600 1600 1000 SSD16*210,H SHD16*210,H


1600 SSD16*216,H SHD16*216,H
D

2000 2000 2000 SSD20*220,H SHD20*220,H


1000 SSD25*210,H SHD25*210,H
2500 2000 SSD25*220,H SHD25*220,H
A

3000
N

2500 SSD25*325,H SHD25*325,H


3000 3000 SSD30*330,H SHD30*330,H
4000 4000 4000 SSD40*440,H SHD40*440,H
1 Add 'H' suffix to product number for high-range instantaneous protection. High-range
instantaneous feature available only with MicroVersaTrip Plus or MicroVersaTrip PM.
2 80% rated.
*Replace * with B for MicroVersaTrip Plus or PM trip unit: or D for Power+ trip unit.

8-110 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Low Voltage Power & Insulated Case Circuit Breakers Section 8
Power Break II Circuit Breakers
Trip Unit Selection

How to Order 5. For replacement trip units, add suffix R. Check Elitenet for
1. Determine the basic trip unit product number. List Price and GO schedule.
Example:
2. Determine the type of trip unit, EntelliGuard TU , Power+,
1600 Ampere frame, 1000 ampere sensor, Long-time (L). Short-time
MicroVersaTrip Plus or MicroVersaTrip PM trip unit.
(S), Instantaneous (I), MicroVersaTrip PM with metering only.
3. Select the trip unit suffix representing the protection function to Order B210LSIM. The replacement trip unit product number
complete trip unit product number. would be B210LSIMR.
4. Order rating plug separately.

Power Break II Trip Unit Suffix Basic Trip Unit Selection


Power+ Trip Unit Suffix Selection
Frame Frame Enhanced MicroVersaTrip
Trip Unit Size Rating Sensor EntelliGuard TU Power+ Plus and MicroVersaTrip
Suffix1 Trip Indicators (Amperes) (Amperes) (Amperes) Trip Unit Trip Units PM Trip Units
Long-Time Short-Time Inst.
Adjustable Instantaneous L/ST/I1 GF2 (L) (ST) (l) 200 GB102 D202 B202
LI 800 800 400 GB105 D204 B204
LIT 800 GB108 D208 B208
LIT2 800 GB108 D208 B208
LSI 1600 1000 GB210 D210 B210
1600-2000
LSIT1 1600 GB316 D216 B216
LSIT2 2000 2000 GB320 D220 B220
1 For high-range instantaneous or zone selective interlocking select 1000 GB310 D210 B210
MicroVersaTrip Plus or PM trip units. 2500 2000 GB420 D220 B220
2 For ground fault-protection, select appropriate rating plug. 2500-3000
2500 GB425 D325 B325
3000 3000 GB530 D330 B330
4000 4000 4000 GB740 D440 B440

EntelliGuard TU with Selectable Phase Ammeter - Trip Indicators Standard


Overcurrent Trip Selectable Phase Long-Time Long-Time with Switchable Inst Ground Fault Ground Fault GF/ST Zone
Suffix 11 Protections Indicators Ammeter (L) Fuse Settings (J) Short-Time (ST) (I) (G) Alarm (GA) Interlock (ZSI)3
L3** LSI (S, switchable) opt.
L4** LSIG (S, switchable) opt.
L5** LSIGA (S, switchable) opt.
L8** LSIGDA (GF/S, switchable)2 opt.
1Add suffix to basic trip unit to product number.
2Defeatable/Switchable Ground Fault, not UL Listed.

MicroVersaTrip Plus with Selectable Phase AmmeterTrip Indicators Standard


Trip Unit Trip Selectable Long-Time Short-Time Inst. High Inst. Ground Fault GF Zone GF/ST Zone
Suffix 3 Indicators Phase Ammeter (L) (ST) (I) (H) (G) 4 Interlock (Z1)5 Interlock (Z2) 5
Adjustable Instantaneous
LI
LIG
LIG Z1
LSI
LSIG
LSIGZ1
LSIGZ2
Fixed High Range Instantaneous 6
LSH
LSHG
LSHGZ1
LSHGZ2
3 Add suffix to basic trip unit product number.
4 For single-phase 3 wire or 3-phase, 4-wire applications, order appropriate neutral current sensor separately, page 8-123.
Defeatable Ground Fault (not UL Listed) is available. Use code GD in place of G.
5 Requires purchase of Zone Selective Interlock module(s) Type TIM1 (120 Vac control voltage).
6 Not available on 4000A stationary breaker frame.

Rev. 11/13 www.geindustrial.com BuyLog Catalog 8-111


Data subject to change
without notice
Low Voltage Power & Insulated Case Circuit Breakers Section 8
Power Break II Circuit Breakers
Trip Unit Selection

MicroVersaTrip PM with Metering and CommunicationsTrip Indicators Standard

9
Trip Unit Trip Selectable Long-Time Short-Time Inst. High Inst. Ground Fault GF Zone GF/ST Zone

9
ER
Suffix1 Indicators Phase Ammeter (L) (ST) (I) (H) (G) 2 Interlock (Z1) 3 Interlock (Z2) 3

R . TA P P O . 8 -
Adjustable Instantaneous

TO E N O R E E G I
LIM

RA S F S P I

R .
W
FO G
G PR O N O K
LIGM
LIGZ1M

N
LSIM

I
F I E AT A E A
LSIGM

VE C
LSIGZ1M

N S R UR ER UR BRE
U E R D N
LSIGZ2M

I
TI R
Fixed High Range Instantaneous 4
LSHM
LSHGM
LSHGZ1M
LSHGZ2M
FI M L A ER













O N N W

MicroVersaTrip PM with Protective Relays and CommunicationsTrip Indicators Standard


CO E G B T
CT C CT E P O

Trip Unit Trip Selectable Long-Time Short-Time Inst. High Inst. Ground Fault GF Zone GF/ST Zone
Suffix 1 Indicators Phase Ammeter (L) (ST) (I) (H) (G) 2 Interlock (Z1) 3 Interlock (Z2) 3
Adjustable Instantaneous
SA N U C

LIP
TA I I U M E

LIGP
N K D NO SE

LIGZ1P
LSIP
LSIGP

CO E A R O ED TE:

LSIGZ1P
LSIGZ2P
Fixed High Range Instantaneous 4
BR R A NO

LSHP
LSHGP
LSHGZ1P
LSHGZ2P
L
T

MicroVersaTrip PM with Metering, Protective Relays and CommunicationsTrip Indicators Standard


FO PD

Trip Unit Trip Selectable Long-Time Short-Time Inst. High Inst. Ground Fault GF Zone GF/ST Zone
Suffix1 Indicators Phase Ammeter (L) (ST) (I) (H) (G) 2 Interlock (Z1) 3 Interlock (Z2) 3
P

Adjustable Instantaneous
U

LIPM
LIGPM
LIGZ1PM
LSIPM
LSIGPM
LSIGZ1PM
LSIGZ2PM
Fixed High Range Instantaneous 4
LSHPM
LSHGPM
LSHGZ1PM
LSHGZ2PM
1 Add suffix to basic trip unit product number.
2 For single-phase 3 wire or 3-phase, 4-wire applications, order appropriate neutral current sensor separately, page 8-123.
Defeatable Ground Fault (not UL Listed) is available. Use code GD in place of G.
3 Requires purchase of Zone Selective Interlock module(s) Type TIM1 (120 Vac control voltage).
4 Not available on 4000A stationary breaker frame.

8-112 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Low Voltage Power & Insulated Case Circuit Breakers Section 8
Power Break II Circuit Breakers
Enhanced MicroVersaTrip, Rating Plug Selection

Power Break II Rating Plug Selection


Enhanced
MicroVersaTrip Plus
Power+ Trip and Enhanced
Frame Sensor Current Power+ Trip Unit Ground MicroVersaTrip PM EntelliGuard TU
Size Rating Rating Unit Standard Fault Rating Trip Unit Trip Unit
(Amperes) (Amperes) (Amperes) Rating Plugs Plugs Rating Plugs Rating Plugs
100 TR2C100 TR2C100GF TR2B100 GTP0100U0103
200 150 TR2C150 TR2C150GF TR2B150 GTP0150U0104
200 TR2C200 TR2C200GF TR2B200 GTP0200U0204
150 TR4B150 GTP0150U0104
800 200 TR4C200 TR4C200GF TR4B200 GTP0200U0204
225 TR4C225 TR4C225GF TR4B225 GTP0225U0306
400
250 TR4C250 TR4C250GF TR4B250 GTP0250U0407
300 TR4C300 TR4C300GF TR4B300 GTP0300U0408
400 TR4C400 TR4C400GF TR4B400 GTP0400U0410
300 TR8B300 GTP0300U0408
400 TR8C400 TR8C400GF TR8B400 GTP0400U0410
450 TR8C450 TR8C450GF TR8B450 GTP0450U0612
800-1600 800 500 TR8C500 TR8C500GF TR8B500 GTP0500U0613
600 TR8C600 TR8C600GF TR8B600 GTP0600U0616
700 TR8C700 TR8C700GF TR8B700 GTP0700U0816
800 TR8C800 TR8C800GF TR8B800 GTP0800U0820
400 TR10B400 GTP0400U0410
1000 600 TR10C600 TR10C600GF TR10B600 GTP0600U0616
800 TR10C800 TR10C800GF TR10B800 GTP0800U0820
1000 TR10C1000 TR10C1000GF TR10B1000 GTP1000U1025
600 TR16B600 GTP0600U0616
1600
800 TR16C800 TR16C800GF TR16B800 GTP0800U0820
1000 TR16C1000 TR16C1000GF TR16B1000 GTP1000U1025
1600
1100 TR16C1100 TR16C1100GF TR16B1100 GTP1100U1225
1200 TR16C1200 TR16C1200GF TR16B1200 GTP1200U1232
1600 TR16C1600 TR16C1600GF TR16B1600 GTP1600U1640
750 TR20B750 GTP0750U0820 MicroVersaTrip and MicroVersaTrip PM
800 TR20B800 GTP0800U0820
Rating Plug
1000 TR20C1000 TR20C1000GF TR20B1000 GTP1000U1025
2000 2000 1200 TR20C1200 TR20C1200GF TR20B1200 GTP1200U1232
1500 TR20C1500 TR20C1500GF TR20B1500 GTP1500U1640
1600 TR20C1600 TR20C1600GF TR20B1600 GTP1600U1640
2000 TR20C2000 TR20C2000GF TR20B2000 GTP2000U2050
400 TR10B400 GTP0400U0410
600 TR10C600 TR10C600GF TR10B600 GTP0600U0616
1000
800 TR10C800 TR10C800GF TR10B800 GTP0800U0820
1000 TR10C1000 TR10C1000GF TR10B1000 GTP1000U1025
750 TR20B750 GTP0750U0820
800 TR20B800 GTP0800U0820
1000 TR20C1000 TR20C1000GF TR20B1000 GTP1000U1025 Power+ Trip Target Module
2500 2000 1200 TR20C1200 TR20C1200GF TR20B1200 GTP1200U1232
1500 TR20C1500 TR20C1500GF TR20B1500 GTP1500U1640
1600 TR20C1600 TR20C1600GF TR20B1600 GTP1600U1640
2000 TR20C2000 TR20C2000GF TR20B2000 GTP2000U2050
1600 TR25C1600 TR25C1600GF TR25B1600 GTP1600U1640
2500 2000 TR25C2000 TR25C2000GF TR25B2000 GTP2000U2050
2500 TR25C2500 TR25C2500GF TR25B2500 GTP2500U2564
1200 TR30C1200 TR30C1200GF TR30B1200 GTP1200U1232
1600 TR30C1600 TR30C1600GF TR30B1600 GTP1600U1640
3000 3000 2000 TR30C2000 TR30C2000GF TR30B2000 GTP2000U2050
2500 TR30C2500 TR30C2500GF TR30B2500 GTP2500U2564
3000 TR30C3000 TR30C3000GF TR30B3000 GTP3000U3064
1600 TR40C1600 TR40C1600GF TR40B1600 GTP1600U1640 EntelliGuard TU Rating Plug
2000 TR40C2000 TR40C2000GF TR40B2000 GTP2000U2050
2500 TR40C2500 TR40C2500GF TR40B2500 GTP2500U2564
4000 4000
3000 TR40C3000 TR40C3000GF TR40B3000 GTP3000U3064
3600 TR40C3600 TR40C3600GF TR40B3600 GTP3600U4064
4000 TR40C4000 TR40C4000GF TR40B4000 GTP4000U4064

Power+ Target Module


Trip Indicator Product
Power+ trip units are designed to accept an optional field-installable L/ST/1 Ground Fault Number
target module. The target module indicates long-time pickup, TARGET00
TARGET01
battery status, trip unit health status, and whether a breaker trip TARGET02
was caused by an overload, a short circuit or a ground fault. Target
modules are available with or without ground fault indication.

Rev. 11/13 www.geindustrial.com BuyLog Catalog 8-113


Data subject to change
without notice
Low Voltage Power & Insulated Case Circuit Breakers Section 8
Power Break II Molded Case Switch
Old Product Numbers Stationary and Draw-out Switch Selection

How to Order Power Break II Rating Plug Selection


1. Choose a frame from the Molded Case Switch Frame tables below Basic Control Current Rating Power + Standard Power + Ground Fault
Unit (Amperes) Rating Plug Rating Plug
2. Select a Control Unit from the Control Unit table below. The D208 800 TR8C800 TR8C800GF
sensor rating of the control unit should match the sensor D210 1000 TR10C1000 TR10C1000GF
D216 1600 TR16C1600 TR16C1600GF
rating of the switch. Choose a control unit with suffix T2 to D220 2000 TR20C2000 TR20C2000GF
get ground fault target indication. D325 2500 TR25C2500 TR25C2500GF
D330 3000 TR30C3000 TR30C3000GF
3. Select a rating plug from the table to the right. D440 4000 TR40C4000 TR40C4000GF

4. Select all other accessories just as for any Power Break II


Circuit Breaker.

Molded Case Switch FramesStationary Ordering Example SSD2Y4A2H200220


Switch Envelope Switch Frame Current Sensor Product
Size (Amperes) Size (Amperes) Rating (Amperes) Number
1600 ampere drawout switch; factory installed 240 Vac electric
800 800 800 SSF08Y208
(motor) operator; 240 Vac remote close solenoid; 24 Vac/DC shunt
1600 1600 1600 SSF16Y216 trip; drawout substructure; drawout secondary disconnect;
2000 2000 2000 SSF20Y220 drawout shutter.
SSF25Y325
2500 2500
SSB25Y325
3000
3000 3000
SSF30Y330 Note: See Power Break II updated nomenclature on page
SSB30Y330
8-99 for product number and see Power Break II configurator
for pricing. Contact sales representative for configurator.
Molded Case Switch FramesDraw-out1
Switch Envelope Switch Frame Current Sensor Product
Size (Amperes) Size (Amperes) Rating (Amperes) Number
800 800 800 SSD08Y208
1600 1600 1600 SSD16Y216
2000 2000 2000 SSD20Y220
2500 2500 SSD25Y325
3000
3000 3000 SSD30Y330
4000 4000 4000 SSD40Y440
1Use only with Hi-Break draw-out substructure.

Control Units
Switch Envelope Switch Frame Sensor Product
Size (Amperes) Size (Amperes) (Amperes) Number
D208
800 800 800
D208T2
D210
1000
D210T2
1600 1600
D216
1600
D216T2
D220
2000 2000 2000
D220T2
D210
1000
D210T2
D220
2500 2000
D220T2
3000
D325
2500
D325T2
D330
3000 3000
D330T2
D440
4000 4000 4000
D440T2

8-114 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Low Voltage Power & Insulated Case Circuit Breakers Section 8
Power Break II Circuit Breakers
Stationary and Draw-out Breaker Accessories
All devices UL Listed for factory or field installation except where noted.

AccessoriesStationary and Draw-out Breakers


The complete line of Power Break II breaker accessories may be either factory or field
installed to meet user needs. The electronic shunt trip, the bell alarm, the bell alarm with
mechanical lockout, and the undervoltage release modules are drop-in from the front of
the breaker, interchangeable across all frames, and require no field internal wiring or
breaker disassembly. Auxiliary switch modules are available in groups of 4, 8 or 12,
NO/NC single-pole, double-throw (SPDT) switches. Their installation simply involves
removal of breaker cover, installation of the switch module, routing of wiring and instal-
lation of the pre-wired terminal block and re-installation of the cover. Auxiliary switches
are also interchangeable across all Power Break II breaker frames.

Electrical Operator
The electrical operator mounts inside the front cover of the manually operated breaker.
This accessory can be added to any Power Break II breaker in the factory or the field
to provide electrical spring charging and charge indication. For remote closing, the
remote close solenoid must be ordered separately. All breakers are prewired to dedi-
cated secondary terminals for easy field installation. When electrical operation is used,
either a shunt trip or an undervoltage release must be ordered separately.

Ratings Ratings Field Installable Factory Installed


Vac Vdc Product Number Product Number
120 SPE120R SPE120
240 SPE240R SPE240
24 SPE024R SPE024
48 SPE048R SPE048
72 SPE072R SPE072
125 SPE125R SPE125
Electrical Operator

Remote Close Solenoid


This accessory provides an electrically operated solenoid which, when energized, closes
the breaker. It is suitable for control interlock schemes in which manual closing capabili-
ty would not be convenient or desirable. The breaker is provided with a manual close
button, which can be replaced by the Hidden "ON" Button accessory and/or sealed using
the Limited Access Pushbutton Cover accessory. The remote close accessory is continu-
ously rated and has an anti-pump feature, which prevents a motor operated breaker
from repeatedly closing into a fault. Closing control voltage must be removed and re-applied
for each breaker closure.

Ratings Ratings Field Installable Factory Installed


Vac Vdc Product Number Product Number
120 SPRCS120R SPRCS120
240 SPRCS240R SPRCS240
24 SPRCS024R SPRCS024 Remote Close Solenoid
48 SPRCS048R SPRCS048
72 SPRCS072R SPRCS072
125 SPRCS125R SPRCS125

Rev. 11/13 www.geindustrial.com BuyLog Catalog 8-115


Data subject to change
without notice
Low Voltage Power & Insulated Case Circuit Breakers Section 8
Power Break II Circuit Breakers
Stationary and Draw-out Breaker Accessories
All devices UL Listed for factory or field installation except where noted.

Shunt Trip
The shunt trip accessory is an electronic module, which provides remote control capabil-
ity to open the circuit breaker. When activated, the shunt trip module sends a signal to
the trip unit to open the breaker. This allows the trip unit to record, display, distinguish
and communicate (in MicroVersaTrip PM trip units) that the opening event was initiated
by the shunt trip device. The shunt trip is continuously rated and requires no cut-off
switch. When energized, the shunt trip supplies +24Vdc power to the trip unit to power
the display.

Ratings Ratings Field Installable Factory Installed


Vac Vdc Product Number Product Number
12 SPST012R SPST012
24 24 SPST024R SPST024
48 48 SPST048R SPST048
120 125 SPST120R SPST120 Shunt Trip Module
208 SPST208R SPST208
240 250 SPST240R SPST240
480 SPST480R1 SPST4801
600 SPST600R1 SPST6001
1Kit contains externally mounted transformer.

Shunt Trip with Lockout Module


The shunt trip with lockout is identical to the regular shunt trip, but when energized, it
will also prevent closure of an "open" breaker by mechanically blocking both manual and
electrical closing. When energized, the closing springs will not discharge, the movable
contacts will not move; the contacts are "kiss free."

Ratings Ratings Field Installable Factory Installed


Vac Vdc Product Number Product Number
12 SPSTL012R SPSTL012
24 24 SPSTL024R SPSTL024
48 48 SPSTL048R SPSTL048
120 125 SPSTL120R SPSTL120
208 SPSTL208R SPSTL208
240 250 SPSTL240R SPSTL240
480 SPSTL480R1 SPSTL480
600 SPSTL600R1 SPSTL600
1Kit contains externally mounted transformer.

8-116 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Low Voltage Power & Insulated Case Circuit Breakers Section 8
Power Break II Circuit Breakers
Stationary and Draw-out Breaker Accessories
All devices UL Listed for factory or field installation except where noted.

Undervoltage Release Module


The undervoltage release is an electronic module used to open the circuit breaker when
the monitored voltage drops below 35-60% of its rated value. The undervoltage release
"resets" when the monitored voltage is re-established allowing the circuit breaker to re-
close (the sealing voltage of the UVR is 60-85% of its rated voltage).
An undervoltage release trip operation is produced by the MicroVersaTrip Plus unit in
response to a signal from the undervoltage release module. This allows the trip unit to
record, display, distinguish and communicate (in MicroVersaTrip PM trip units) that the
breaker opening event was due to undervoltage release. Operation of the undervoltage
release module will prevent breaker contact closure, i.e. "kiss-free" operation. When
energized, the undervoltage release supplies +24 Vdc power to the trip unit to power
the display.
Ratings Ratings Field Installable Factory Installed Undervoltage Release Module
Vac Vdc Product Number Product Number
24 SPUV024ACR SPUV024AC
48 SPUV048ACR SPUV048AC
120 SPUV120ACR SPUV120AC
208 SPUV208ACR SPUV208AC
240 SPUV240ACR SPUV240AC
480 SPUV480ACR1 SPUV480AC1
600 SPUV600ACR1 SPUV600AC1
12 SPUV012DCR SPUV012DC
24 SPUV024DCR SPUV024DC
48 SPUV048DCR SPUV048DC
125 SPUV125DCR SPUV125DC
250 SPUV250DCR SPUV250DC
1Kit contains externally mounted transformer.

Time Delay Module for UVR


The time delay module prevents nuisance tripping due to momentary loss of voltage.
The module has 120 Vac input and 125 Vdc output and must be used with the 125 Vdc UVR.

Description Product Number


Time Delay Module
(0.1 to 1.0 second delay) SPUVTD

Bell Alarm (Alarm Only)


The bell alarm module is used to signal breaker "tripped" status to other accessories
(e.g., external alarm devices, indicating lights, relays, or logic circuits) for remote indica-
tion and interlocking functions. The bell alarm response is configurable by means of
rear-mounted DIP switches on the trip unit. The bell alarm can be made to operate in
response to an overcurrent (including ground fault) or protective relay trip and/or a
shunt trip operation, and/or operation of the undervoltage release module. It is not
actuated as a result of normal breaker "ON/OFF" operation.
This module provides a visual, mechanical pop-out target, which protrudes through the
face of the circuit breaker door when it operates. The bell alarm may be reset manually
by depressing the mechanical target, or automatically by closing the breaker.
The bell alarm is provided with one SPDT switch with control power duty contacts as
shown in the auxiliary switch accessories. Bell (Alarm Only)

Ratings Ratings Field Installable Factory Installed


Vac Vdc Product Number Product Number
240 125-250 SPBAA240R SPBAA240
600 125-250 SPBAA600R1 SPBAA6001
1600 Vac module not UL Listed.

Rev. 11/13 www.geindustrial.com BuyLog Catalog 8-117


Data subject to change
without notice
Low Voltage Power & Insulated Case Circuit Breakers Section 8
Power Break II Circuit Breakers
Stationary and Draw-out Breaker Accessories
All devices UL Listed for factory or field installation except where noted.

Bell Alarm With Lockout


The bell alarm with lockout module combines both the bell alarm and a manual lockout
function. The bell alarm switch operates identically to the standard bell alarm module,
except that the mechanical pop-out target must be manually reset before the breaker
can be closed.
Operation of the bell alarm with lockout module can be independently set by means
of setting the DIP switches at the rear of the trip unit. Current rating of the single SPDT
switch is identical to the auxiliary switch accessories.
Ratings Ratings Field Installable Factory Installed
Vac Vdc Product Number Product Number
240 125-250 SPBAL240R SPBAL240
600 125-250 SPBAL600R1 SPBAL6001
1600 Vac module not UL Listed.
Bell Alarm with Mechanical Reset Lockout

Auxiliary Switch
An auxiliary switch signals the circuit breakers primary contact position (i.e., OPEN or
CLOSED) to other devices, such as indicating lights, relays or logic circuits. This enables
the user to provide remote indication, interlocking or control operations as a function of
breaker primary contact position. The auxiliary switch operation is independent of the
method by which the breaker is opened or closed. The auxiliary switch does not distin-
guish between a "tripped" or "open" condition. The auxiliary switch contacts follow the
main breaker contacts on opening and precede them on closing.
Auxiliary switch modules are available with 4, 8 or 12 NO/NC (SPDT) switches for control
power duty ac/dc ratings. When ordered for field installation, an auxiliary switch module
comes pre-wired to its own terminal board, which mounts with one screw to the left of
the breaker. A special accessory, available for draw out breakers, comes pre-wired to the
breaker secondary disconnect. All switch ratings are 6A at 120V-600 Vac, 1/2A at 125
Vdc and 1/4A at 250 Vdc.
Auxiliary Switch with
Pre-wired Secondary Terminals
for Stationary Breaker
Auxiliary Switches for Stationary Breakers
No. of SPDT
Ratings Ratings Switch Elements Field Installable Factory Installed
Vac Vdc (Contacts) Product Number Product Number
240 125-250 4 SPAS240AB4R SPAS240AB4
240 125-250 8 SPAS240AB8R SPAS240AB8
240 125-250 12 SPAS240AB12R SPAS240AB12
600 125-250 4 SPAS600AB4R1 SPAS600AB41
600 125-250 8 SPAS600AB8R1 SPAS600AB81
1600 Vac module not UL Listed.

Auxiliary Switches for Draw-out Breakers


No. of SPDT
Ratings Ratings Switch Elements Field Installable Factory Installed
Vac Vdc (Contacts) Product Number Product Number
240 125-250 4 SPAS240AB4DR SPAS240AB4D
240 125-250 8 SPAS240AB8DR SPAS240AB8D
240 125-250 12 SPAS240AB12DR SPAS240AB12D
600 125-250 4 SPAS600AB4DR1 SPAS600AB4D1
600 125-250 8 SPAS600AB8DR1 SPAS600AB8D1
Auxiliary Switch with
1600 Vac module not UL Listed.
Pre-wired Secondary Terminals
for Draw-out Breaker

8-118 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Low Voltage Power & Insulated Case Circuit Breakers Section 8
Power Break II Circuit Breakers
Stationary and Draw-out Breaker Accessories
All devices UL Listed for factory or field installation except where noted.

Mechanical Operations Counter


The mechanical operations counter is mounted behind the front cover of the breaker. It
is viewable through a rectangular knockout window opening in the breaker cover. It is a
five-digit, non-resettable counter, which is actuated each time the breaker is opened by
any means.
Field Installed Factory Installed
Product Number Product Number
SPCOUNTERR SPCOUNTER
Mechanical Operations Counter

Limited Access Pushbutton Cover


This accessory limits access to "ON/OFF" control of a breaker to authorized personnel.
The pushbutton cover accessory consists of transparent hinged covers that can be indi-
vidually sealed to the limited access assembly. Both the "ON" and "OFF" buttons can be
pilot drilled to allow use of a 1/8" rod to operate either one or both pushbuttons.
Field Installed Factory Installed
Product Number Product Number
SPPBCOVERR SPPBCOVER

Breaker with limited access pushbutton


cover assembly installed

Hidden "ON" Button


The hidden "ON" button is assembled to the mechanism behind an unlabeled, false
pushbutton. Manual closing of the breaker can only be performed by means of a small
diameter rod. This accessory is used to limit access to the manual "ON" control to
authorized personnel.
Field Installed Factory Installed
Product Number Product Number
SPPBNONR SPPBNON

Activating the breaker closing


mechanism through the hole in the
Hidden ON Button
Maintenance/Repair Parts
Description Product Number
Top Cover and Rating Labels SPBIICOVER1
Replacement MVT Door 10054335P1
Replacement Powerplus Door 10054335P2
Stop Block Kit w/Installation Tool SPBUMPERKIT
Visible On Button Conversion SPPBRONR
PB1 SM FR Door Interlock/Padlock TSPL
800A PB1 to PB2 Stationary Retrofit Kit SSF08TPCCR2
1600A PB1 to PB2 Stationary Retrofit Kit SSF16TPCCR2
2000A PB1 to PB2 Stationary Retrofit Kit SSF20TPCCR2
2500A-4000A PB1 to PB2 Stationary Retrofit Kit SSF40TPCCMR3
2500A-4000A PB1 to PB2 Stationary Retrofit Kit SSF40TPCCER4
Replacement Breaker Secondary Disconnect SPDOSD36B
1Special handling and order entry required to preserve UL Listing of breaker.
Contact Post Sale Service for additional details of special process.
2Manually or electrically operated
3Manually operated
4Electrically Operated

Rev. 11/13 www.geindustrial.com BuyLog Catalog 8-119


Data subject to change
without notice
Low Voltage Power & Insulated Case Circuit Breakers Section 8
Power Break II Circuit Breakers
Stationary and Draw-out Breaker Accessories
All devices UL Listed for factory or field installation except where noted.

Key Interlock Provisions


The key interlock provision enables the user to mount a one- to four-cylinder, narrow-
faced, Kirk-type FN or Superior customer-supplied lock on the face of the breaker. This
accessory provides mounting for key interlocks that are furnished by the customer. The
key interlock provision works in conjunction with the padlock provision. The key interlock
extends a lever through the padlock hasp when the key is turned to the key removal or
bolt extended position. Additionally, the accessory provides a hasp for mounting three
padlocks with 1/4" to 3/8" diameter shanks.

Key Interlock Reference Table


Kirk Key Lock Superior
Product Number Number of Locks Product Number Product Number
SPK4 1 KFN000011 S105827Y
SPK4 2 KFN000021 S105828Y
SPK4 3 KFN000031 S105829Y
SPK4 4 KFN000041 S105827-4Y
Key Interlock Kit (lock not included)
1Final digit may be 0, 1, 2 or 3 depending on number of key removal positions.

Product Numbers, Key Interlock Provisions


Circuit Breaker Number of Field Installed Factory Installed
Envelope Size (Amps) Key Locks Product Number Product Number
All 1 to 4 SPK4R SPK4

Door Interlock
The door interlock provides interlocking of the circuit breaker compartments hinged
door so that the breaker must be in the "OFF" position before the door can be opened.
The door interlock is defeatable with a small tool to allow authorized access.

Field Installed Factory Installed


Product Number Product Number
SPDILR SPDIL

Padlock Provisions (Standard) Door Interlock


Padlocking provisions are standard on all Power Break II circuit breakers. When the
breaker is in the open position, and the padlock hasp is raised at least 1/4", the breaker
cannot be closed mechanically or electrically. The hasp accepts up to three padlocks
with 1/4" to 3/8" diameter shanks.

Walking Beam InterlocksStationary Breakers Only


Walking beam interlocks are mechanical devices used to prevent two adjacent circuit
breakers from both being in the "ON" or closed position at the same time. However, both
breakers can be in the "OFF" or open position. Adjacent circuit breakers can be laterally
or vertically mounted.
Circuit Breaker
Envelope Size (Amperes) Product Number
800, 1600 and 2000 SPWB20
3000 SPWB30
4000 SPWB40

8-120 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Low Voltage Power & Insulated Case Circuit Breakers Section 8
Power Break II Circuit Breakers
Stationary Breaker Mounting Kits
All devices UL Listed for factory or field installation except where noted.

Lug Adapter Kits


Kits pre-mount to bus structure allowing cabling or bussing to be completed prior to
breaker mounting. Accepts either lugs or crimp-type connector terminals. Kit includes
adapter and hardware for either a three-pole line-side, or a three-pole load-side connec-
tion. (Lugs not included).
Frame Product Suitable for
Rating (Amperes) Number use with up to:
3 TPLUG108 Lugs or
2000 Ampere Power Break II breaker with
800 TPLUGA08 3 crimp Lugs1 per pole SPLUGA20 lug adapter kit and 18 lugs
6 TPLUG108 lugs or (TPLUG108)
1600 TPLUGA162 6 crimp Lugs1 per pole
6 TPLUG108 Lugs or
2000 SPLUGA203 6 crimp Lugs1 per pole
1Anderson No. VCEL-075-12H1 or equivalent
2T-Studs - TP16FCA - included with adapter
3T-Studs - SP20FCA - included with adapter

Lug Kits
Kits accept Cu/AI wire and are suitable for direct mounting to the breaker. When order-
ing Type TPLUG kits, order one kit per line or load pole. Example: A complete set of lugs
for the line side of an 800A frame, 400A trip breaker would be Qty 3-TPLUG106 lugs. Type TPLUG206
When ordering TSLUG kits order one kit per line or load side; TSLUG kits require use of
T-studs. Example: A complete set of lugs for a 3000A frame, 2500A trip breaker would be
Qty 1-TSLUG25. T-Studs would also be required.

Circuit Breaker Max Rating Product Lug Max. Cables Wire Range
Envelope Size (Amperes) (Amperes) Number Per Kit Per Pole kcmil Cu/AI
400 TPLUG106 1 1 (2) #2 2-600
600 TPLUG206 1 2 (2) #2 2-600
800
800 TPLUG308 1 3 (3) 300-750
800 TPLUG1084 1 3 3/0-800
800 TPLUG1084 1 6 3/0-800
1600
1600 TPLUG408 1 4 500-800
2000 TPLUG1084 1 6 3/0-800 Type TPLUG408
800 TSLUG08 9 3 3/0-800
2000
1200 TSLUG12 12 4 3/0-800
1600 TSLUG16 15 5 3/0-800
2000 TSLUG20 18 6 3/0-800
3000 2500 TSLUG25 21 7 3/0-800
3000 TSLUG30 27 9 3/0-800
4000 4000 TSLUG40 27 9 3/0-800
4For use with adapter kit only. See table above.

Type TPLUG308

Type TSLUG20

Rev. 11/13 www.geindustrial.com BuyLog Catalog 8-121


Data subject to change
without notice
Low Voltage Power & Insulated Case Circuit Breakers Section 8
Power Break II Circuit Breakers
Stationary Breaker Mounting Kits, Wall Mounted Enclosures, Floor Mounted Enclosures
All devices UL Listed for factory or field installation except where noted.

T-Studs
T-studs mount directly to the breaker, and can be rotated for either vertical or horizontal
bus connection. 4000 ampere T-studs are for vertical bus bars only. Product number
includes one stud. Both copper and aluminum T-studs are tin-plated.

T-StudsFront Connected Breaker


Circuit Breaker Max. Rating
Frame Size (Amperes) (Amperes) Product Number
800 800 SP08FCA1
800 800 SP08FCC2
1600, 2000 2000 SP20FCA1
1600, 2000 2000 SP20FCC2
2500 2000 SPS20FCA1
2500 2500 SPS25FCC2
3000 3000 SPS30FCC2
4000 4000 SPS40FCC2 2000A Breaker with "T" Studs Mounted
4000 4000 SPS40LFCC2,3

T-StudsBack Connected Breaker


Circuit Breaker Max. Rating
Frame Size (Amperes) (Amperes) Product Number
2500 2000 SPS20BCA1,4
2500 2500 SPS25BCC2
3000 3000 2,4

1Aluminum
2Copper
3Extra long stud. Alternate with SPS40FCC for ease of installation.
4Supplied with integral T-stud

Trimplate
Factory Installed Field Installable
Product Number Product Number
SPTRIMPLATE SPTRIMPLATER

8-122 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Low Voltage Power & Insulated Case Circuit Breakers Section 8
Power Break II Circuit Breakers
Neutral Current Sensors and POWER LEADER Accessories

Neutral Current Sensors1


Circuit Breaker Neutral Sensor
Breaker Frame Sensor Rating Rating or Tap Product
(Amperes) (Amperes) Settings (Amperes) Number
200 200 TSVG302
800 400 400/200 TSVG304A
400 600/3002 TSVG306A
800-1600 800 800/400 TSVG308A
1000 800/4002 TSVG808A
1000 1000/500 TSVG810A
1600
1600 1200/6002 TSVG812A
1600 1600/1000 TSVG816A
2000 2000 2000/1000 TSVG820A
1000 800/4002 TSVG808A
Neutral Current Sensor
1000 1000/500 TSVG810A
1000 1200/6002 TSVG812A
3000 1000 1600/10002 TSVG816A
2000 2000/1200 TSVG820A
2500 2500/1800 TSVG825A
3000 3000/2400 TSVG830A
4000 4000 4000/3000 TSVG940A
1Match neutral current sensor rating (or tap setting) to circuit breaker sensor rating.
2For use with multiple source ground fault protection schemes. Rating does not
match EntelliGuard TU and MicroVersaTrip Plus or PM frame sensor.

Neutral Current Sensors1


Breaker Breaker Neutral Sensor Product Inside
Frame Sensor Rating Rating or Tap Number of Diameter
(Amperes) (Amperes) Settings (Amperes) Window Sensor (inches) SSVG Neutral Current Sensors
800 800 800/400 SSVG808W 4.25
12003 2000/1200 SSVG820W 5.63
1200
16003 1600/1000 SSVG816W 5.63
1600 1600 1600/1000 SSVG816W 5.63
2000 2000 2000/12003 SSVG820W 5.63
POWER LEADER Power Supplies
2500 2500 2500/1800 SSVG825W 5.63 Power supply for furnishing 24Vdc control power for EntelliGuard
3000 3000 4000/3000 SSVG940W 6.50
4000 4000 4000/3000 SSVG940W 6.50 TU, MicroVersaTrip Plus and PM trip units.
1Match neutral current sensor rating (or tap setting) to circuit breaker sensor rating.
System Product
3At time of initial product release, the 1200A new HPC Switch was using 1600A Description Requirements Number
installed sensors and a 1200A rating plug. Later models may or may not use
1.5 ampere power supply
1200A phase sensors. Match Neutral sensor tap to HPC sensor rating.
3Outline Drawing 10112973P1. Price one PLPS4G01 for
each line-up. 45 trip units4 Input power, 100VA
and 100 ft. maximum. (85-265Vac or 100-370Vdc) PLPS4G01
Portable Test Set 420 trip units maximum for EntelliGuard TU
The portable, battery-powered test kit provides self-tests and
functional trip/no trip tests. It also provides defeat of the ground Reference
fault function and can be used in conjunction with high current
Instructions GEH-6492
test equipment. Interface is via a plug on the front of the trip unit
and test can be conducted with the breaker in service. Test kits use
either 120 Vac power source or internal batteries (not included). POWER LEADER Voltage Conditioner
Description Trip Unit Type Product Number Conditions and scales 120 Vac to 1.76 Vac for use by the trip
Portable Test Set MicroVersaTrip only TVRMS2 unit for voltage sensing. Provides transient protection. Voltage
EntelliGuard TU, microEntelliGuard only GTUTK20
conditioners require isolation PTs.
System Product
Portable Battery Pack Description Requirements Number

The hand-held Portable Battery Pack provides an independent Supplies isolated bus
power source for EntelliGuard TU, microEntelliGuard, voltage signal to
EntelliGuard TU and One set of 3 voltage conditioners
MicroVersaTrip Plus and MicroVersaTrip PM trip units as an MicroVersaTrip PM required for each voltage sensing
alternative to a test set. The battery pack is used to power up the trip units. location. PTs also required. PLVC1G01
trip unit to set or adjust trip set points when the breaker is on the
bench or otherwise not powered up. For microEntelliGuard trip
units, the battery pack connects to the trip unit through the Reference
15-pin connector. A battery pack adapter cable is required. Instructions GEH-5946

For MicroVersaTrip Plus and MicroVersaTrip PM trip units, the


battery pack connects to the trip unit through the rating plug Rating Plug Removal Tool
test jack. The battery pack requires three standard 9 Vdc alkaline
batteries (not included). Product Number
Description Product Number TRTOOL
Portable Battery Pack TVPBP
EntelliGuard TU, microEntelliGuard
TVPBPACC
Battery Pack Adapter Cable

Rev. 11/13 www.geindustrial.com BuyLog Catalog 8-123


Data subject to change
without notice
Low Voltage Power & Insulated Case Circuit Breakers Section 8
Power Break II Circuit Breakers
Draw-out Breaker Accessories

Features
Draw-outs through 4000 amperes are UL Listed, 100% rated
Modular design for simplified installation6 basic sizes800, 1600, 2000, 2500 ,
3000 , 4000 5 inch pole centers
Screw racking mechanism provides positive racking motion
Self aligning primary and secondary disconnects
Four position draw-outengaged, test, disengaged, fully withdrawn
simplifies system testing and inspection
Breaker position indicator clearly shows breaker position
Provisions for padlocking breaker in test or disengaged position
Mechanical interlock logic prevents movement of a closed breaker
Suitable for reverse feeding

Description Draw-out Breaker in Substructure


The draw-out assembly consists of a substructure housing unit designed as a compact
self-supporting unit and a draw-out breaker which must be ordered separately. The
substructure contains mounting holes, self-supporting male plugs and extendable rails,
and can be ordered separately for installation in your switchboard or enclosure.
The Power Break II draw-out breaker is a self-contained, heavy-duty assembly designed
to offer simplified breaker inspection without de-energizing the main bus structure.
The draw-out breaker comes complete with racking mechanism drive, wheels, primary
and secondary disconnects and cooperating interlock systems.
Accessories such as dead-front shutters, by-pass switches (position switches), and
padlock devices are available and field installable.

OEM Substructures
Substructures are available for both standard and Hi-Break Power Break II breakers.
Holes are provided for bolting on a shelf or supports. Holes are also provided in the pri-
mary stabs for bolting to busbars or terminal lugs. Substructure secondary disconnects
are ordered and priced separately. Order Hi-Break substructures for use with Power 1600-ampere substructure for
Break II switches. standard break breaker

Frame Rating Standard Break Hi-Break


(Amperes) Product Number Product Number
800 SPSDOS08 SPHDOS08
1600 SPSDOS16 SPHDOS16
2000 SPSDOS20 SPHDOS20
2500 SPSDOS25 SPHDOS25
3000 SPSDOS30 SPHDOS30
4000 SPSDOS40 SPHDOS40

Secondary Disconnect for Draw-out Breakers


Control wiring is connected through draw-out secondary disconnects in the "TEST" and
"CONNECTED" positions only. Up to 72 control circuits are possible through 36 position
plug-style secondary disconnect blocks factory mounted to each side of draw-out
breakers. One substructure disconnect (SPDOSD36S) must be ordered for each breaker
when accessories or communications are used. When auxiliary switches are used along
with any other electrical accessory or communications, two disconnects must be ordered.

Location Product Number


Substructure SPDOSD36S
Breaker1 SPDOSD36B
1Order for replacement only. Included and factory wired with draw-out breaker.

8-124 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Low Voltage Power & Insulated Case Circuit Breakers Section 8
Power Break II Circuit Breakers
Draw-out Breakers and Accessories
All devices UL Listed for factory or field installation except where noted.

Shutter Kit Racking Tool


This field installable kit provides shutters used to prevent uninten- The racking tool is a drive wrench with a square 1/2" socket
tional contact with potentially live primary disconnect stabs when that engages the racking mechanism of the draw-out breaker.
a breaker is racked out of an energized switchboard compartment.
Frame Rating Product Number
Frame Rating Product Number All TDORT
800-2000A SPDSS20
3000A SPDSS30
4000A SPDSS40 Mechanical Interlocks
Mechanical interlocks provide the same function as the walking
By-Pass Switch beam accessory for stationary breakers, except they are used
with two draw-out breakers: mounted on common compartment
Provides positive indication that the draw-out breaker or switch
centerline, in either the same vertical section or adjacent vertical
primary contact fingers are fully connected to the main bus in
sections.
the substructure. Switch contacts change states only after the
primary fingers are fully connected when the breaker is being Envelope Size Product Number
moved from the DISCONNECTED position through the TEST 800-2000 SPDOWB20
position and into the CONNECTED position. 2500-4000 SPDOWB40

May be used to provide control circuit continuity or downstream


signaling that the draw-out breaker is connected in addition to Rail Kit
the visual position indicator on the draw-out substructure. The
This field installable rail kit may be used to shorten the two
By-pass switch accessory does not indicate either the TEST or
standard OEM substructure rails by 3-1/2 inches.
DISCONNECTED position. The switch assembly mounts on the
stationary frame and the actuator mounts to the carriage. Switch Product Number
contacts are rated at 10A at 600 Vac, 0.75A at 125 Vdc, and SPRAILS
0.25A at 250 Vdc.
Number of
Switch Elements Product Number
Position Switch
2 NO/2 NC TDOBP2L
4 NO/4 NC TDOBP4L Provides positive indication when the draw-out breaker or switch
6 NO/6 NC TDOBP6L primary contact fingers have been fully withdrawn from the main
bus connections. Switch contacts change state only after the
primary fingers are fully disconnected when the breaker is being
Racking Padlock Provision moved from the CONNECTED position through the TEST position
The racking padlock provides a means for the user to prevent racking and into the DISCONNECTED position.
tool engagement, thereby preventing movement of the breaker
May be used as part of a safety interlocking system in addition
between the DISCONNECTED, TEST and CONNECTED positions.
to the visual indicator on the draw-out substructure. The Position
Frame Rating Product Number Switch accessory does not indicate either the TEST or CONNECTED
All TDOPC position. The switch assembly mounts on the stationary frame
and the actuator mounts to the carriage. Switch contacts are
rated at 10A at 600 Vac, 0.75A at 125 Vdc, and 0.25A at 250 Vdc.
Lifting Bar Number of
Switch Elements Product Number
The lifting bar provides a means of safely lifting a draw-out circuit
2 NO/2 NC SDOPS2L
breaker. A chain hook can be attached to the central hole in the 4 NO/4 NC SDOPS4L
lifting bar or a 1" diameter black iron pipe can be put through the 6 NO/6 NC SDOPS6L
two holes above the hooks, allowing two people to carry the
breaker below waist level from either side of the breaker.
Frame Rating Product Number
All TDOLB

Rev. 11/13 www.geindustrial.com BuyLog Catalog 8-125


Data subject to change
without notice
Low Voltage Power & Insulated Case Circuit Breakers Section 8
Reference Publications
UL/CSA File Numbers
Power Break Breakers E11592/LR10263 24 Vdc Power Supply GEH-6492
MicroVersaTrip Plus and MicroVersaTrip PM, Arc Chute Kit DEH-41389
EntelliGuard TU Trip Unit and Earthing Device Kit DEH-41379
Power+ Trip Units E11592/LR10263 EntelliGuard TU Rating Plugs DEH-41318
MicroVersaTrip, EntelliGuard TU and EntelliGuard TU Test Kit DEH-4568
Power+ Rating Plugs E11592/LR10263 EntelliGuard TU Trip Unit IOM DEH-4567
Accessories E57253/LR10263
Molded Case Switches E57546/LR16271 Power Break II Time Current Curve-Numbers
Functions Curve No.
EntelliGuard G
Long-time Delay with Instantaneous
EntelliGuard G IOM DEH-41304 or
Enhanced MicroVersaTrip GES-9889
Time Current Curves: EntelliGuard Plus and MicroVersaTrip Long-time Delay, Short-time Delay
TU Trip Unit for EntelliGuard G; PM Trip Units with Instantaneous
Long-Time Circuit Breaker Characteristics DES-090 Ground Fault GES-9890
Time Current Curves: EntelliGuard
TU Trip Unit for EntelliGuard G;
Power Break II Instructions for Breakers and Accessories
Long-Time Fuse-Like Characteristics DES-091
Time Current Curves: EntelliGuard Power Break II Circuit Breakers
TU Trip Unit for EntelliGuard G; 800-4000 A frames, 240-600 Vac GEH-6270
Short-Time Pickup and Delay Bands DES-092 Power Break II Circuit Breakers
Time Current Curves: EntelliGuard Draw-Out 800-4000 Ampere Frames GEH-6271
TU Trip Unit for EntelliGuard G; Power Break II Circuit Breakers
Ground Fault DES-093 Draw-Out Substructure GEH-6272
Time Current Curves: EntelliGuard Power Break II Circuit BreakersTrip Unit GEH-6273
TU Trip Unit for EntelliGuard G; Power Break II Circuit Breaker Accessories
Instantaneous, Override (HSIOC), Auxiliary Switch Module GEH-6274
Reduced Energy Let-Through Instantaneous (RELT) DES-094 Power Break II Circuit Breaker Accessories
UL Component Recognized Series Connected Ratings and Bell Alarm-Alarm Only GEH-6275
CSA Certified Series Rated Combinations DET-008 Power Break II Circuit Breaker Accessories
Undervoltage Release User Manual DEH-41361 Door Interlock GEH-6276
Time Delay Module User Manual DEH-41362 Power Break II Circuit Breaker Accessories
Closing Coil User Manual DEH-41363 Lug Kits and T Studs GEH-4546
Motor Operator User Manual DEH-41366 Power Break II Circuit Breaker Accessories
Electrical Close Switch DEH-41374 Bell Alarm with Lockout GEH-6278
Spring Charge Contact DEH-41375 Power Break II Circuit Breaker Accessories
Castell Lock Kit DEH-41376 Key Interlock Provision GEH-6279
Door Interlock User Manual DEH-41377 Power Break II Circuit Breaker Accessories
Cassette Ronis Lock User Manual DEH-41380 Mechanical Counter GEH-6280
Contact Wear Indicator User Manual DEH-41382 Power Break II Circuit Breaker Accessories
Wall Mounting Kit DEH-41383 Motor Operator Mechanism GEH-6281
IP54 Door DEH-41384 Power Break II Circuit Breaker Accessories
Escutcheon Kit DEH-41386 Push Button Cover GEH-6282
Arcing Contacts Assembly DEH-41390 Power Break II Circuit Breaker Accessories
Racking Handle DEH-41392 Remote Close GEH-6283
Cluster Contacts User Manual DEH-41394 Power Break II Circuit Breaker Accessories
Cluster Pliers Assembly DEH-41395 Shunt Trip GEH-6284
Secondary Disconnects - Drawout DEH-41401 Power Break II Circuit Breaker Accessories
Command Close Coil DEH-41418 Undervoltage Release GEH-6285
Ready To Close (RTC) DEH-41419 Power Break II Circuit Breaker Accessories
Coil Signaling Contacts DEH-41420 Walking-Beam Interlock GEH-6286
Back Connected Terminations for Cassette DEH-41430 TVRMS2 Test Kit GEK-97367
DEH-41431 Power Break II Circuit Breaker Accessories
DEH-41433 Draw-Out Substructure Secondary Disconnect GEH-6460
DEH-41434 Power Break II Circuit Breaker Accessories
DEH-41437 Draw-Out Substructure Rail Kit GEH-6440
Back Connected Terminations for Breaker DEH-41439 Walking Beam Interlock 800A, 1600A, 2000A GEH-6286
DEH-41440 Walking Beam Interlock 2500-3000A DEH-009
DEH-41441 Walking Beam Interlock 4000A DEH-010
DEH-41442 Draw Out Mechanical Interlock 800-2000A DEH-011
DEH-41443 Draw Out Mechanical Interlock 2500-4000A DEH-012
DEH-41444 Neutral Kit DEH-024
DEH-41445 Hidden ON Button DEH-025
DEH-41608 High Voltage Shunt Trip GEH-6519
Contact Wear Indicator DEH-41446 High Voltage Under Voltage Release GEH-6520
Cluster pad Assembly DEH-41447 Under Voltage Release Time Delay Relay GEJ-4699
DEH-41448 EntelliGuard TU Digital Test Kit DEH-4568A
DEH-41449 EntelliGuard TU Conversion/Upgrade Kits DET-722C
DEH-41450 EntelliGuard TU Conversion Kits DEH-3456
Mechanical Interlocks (Fixed) DEH-41451 EntelliGuard TU Conversion Kits DEH-3456
Mechanical Interlocks (Drawout) DEH-41455 Drawout Position Switch DEH-40528
Cassette Interlock User Manual DEH-41459 Stop Block Kit DEH-40466
Clusters DEH-41460
Network Interlock Device ( NI) DEH-41461 Power Break II Circuit Breakers Trip Units
Flat Front Termination ANSI/UL DEH-41463 Power+ Trip Unit DEH-049
Remote Racking Operator DEH-41467 Installation Operation and Maintenance
Key Interlock Casste Mounted DEH-41500 Manual for the UL Version of the
CVCB Coil Signal Status DEH-41517 EntelliGuard TU Trip Unit DEH-4567
Neutral Sensor Kit Rogowski DEH-41387
Continued on page 8-127

8-126 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Low Voltage Power & Insulated Case Circuit Breakers Section 8
Reference Publications
Power Break II Circuit Breakers
MicroVersaTrip Plus and MicroVersaTrip PM Rating Plugs GEH-5933
EntelliGuard TU Rating Plugs DEH-41318
Enclosures 800-2000A GEH-6503

Power Break II Insulated Case Switches


800-4000A, 240-600 Vac DEH-40380
Power+ Control Units DEH-40381

WavePro Low Voltage Power Breakers


WavePro Small Frame Maintenance Manual, WP-08-20 DEH-136
WavePro Large Frame Maintenance Manual, WP-32-50 DEH-137
Users GuideMicroVersaTrip Plus/PM Trip Units DEH-178
Users GuidePower.+ Trip Unit DEH-179
Power Leader Recommended Power Supplies GEH-5945
Power Leader Voltage Conditioner GEH-5946
Portable Battery Power Pack DEJ-001
Zone Selective Interlock Module GEK-64467
WavePro Small Frame Users Manual, WP-08-20 DEH-134
WavePro Large Frame Users Manual, WP-32-50 DEH-135
Users Guide TVRMS2 Programmer Portable Test Set GEK-97367A
WavePro Small Frame (800-2000A) Renewal Parts Guide DEF-004
WavePro Large Frame (3200-5000A) Renewal Parts Guide DEF-005
WavePro Time-Current Curves (LSI) DES-001
WavePro Time-Current Curves (GF) DES-002
WavePro Time-Current Curves (Special GF) DES-026
WavePro Breaker Application Guide DET-167
WavePro Selection and Pricing Guide DEP-080
WavePro User Publications Summary
WavePro Breakers and AKD-10 Switchgear DEE-194

Gerapid High Speed DC Circuit Breakers


Gerapid Brochure DET-379
Gerapid Application Guide DET-739
Gerapid Users Guide for 2607, 4207, 6007 & 8007 S47183e
Gerapid Users Guide for UL Breakers S47183De
Gerapid Users Guide for Rectifier Breakers 8007R & 10007 DTR01807

Rev. 11/13 www.geindustrial.com BuyLog Catalog 8-127


Data subject to change
without notice
Low Voltage Power & Insulated Case Circuit Breakers Section 8
NOTES:

8-128 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Section Updated 08 / 2016

Disconnect Switches and Operating Mechanisms Section 9

HPC High-Pressure Contact Switch


Overview.........................................................................................................9-2
HPC Switch, New Generation, Nomenclature System...........9-6
Frame Product Number Nomenclature...........................................9-8
EntelliGuard Control Unit Nomenclature ...................................9-10
Application Information, Outlines and Dimensions.................9-11
How to Order .............................................................................................9-13
Accessories.................................................................................................9-14
Reference Publications .........................................................................9-22
Premium Duty QMW, Heavy Duty QMR
Individual Components.........................................................................9-23
Factory Assembled Fuse Clips...........................................................9-25
Handle Operators
Product Ordering Tables.......................................................................9-28
Accessories and Modifications..........................................................9-29
General-Duty HCI
Individual Components.........................................................................9-31
TDR Handle Mechanism
Handle Operating Mechanisms ........................................................9-33
FD1 Fusible IEC Style
Individual Components.........................................................................9-34
Accessories.................................................................................................9-35
Outlines and Dimensions .....................................................................9-37
DILOS Nonfusible Vu-Break IEC Style
Individual Components.........................................................................9-38
Accessories.................................................................................................9-39
Outlines and Dimensions .....................................................................9-40

Rev. 11/13 www.geindustrial.com BuyLog Catalog 9-1


Data subject to change
without notice
Disconnect Switches and Operating Mechanisms Section 9
HPC, New Generation High-Pressure Contact Switch
Top- or Bottom Feed
800-4000 Amperes - 600 Vac Max.
Product Introduction
GE type HPC switches are UL listed in accordance with Standard
977, Fused Power Circuit Devices (UL File No. E-51827). The
charge-after-close mechanism provides stored energy, quick-
make/quick-break operation. Multiple spring-loaded high-pressure
current-carrying contact arms and an arcing contact arm provide
excellent current-carrying capability without sacrificing high inter-
rupting fault performance. These switches are 100 percent rated 1600A HPC Switch (Type SHP, Top-Feed)
and can interrupt, on a make and break basis, a minimum of 12
times their nameplate rating without fuse assistance at 600Vac.
Complete HPC switch and Class L fuse coordination is therefore
achieved for all levels of fault current up to 200,000 rms amperes
symmetrical at 600Vac maximum. Type HPC switches used as
service disconnects comply with the National Electrical Code
Article 110.10 for adequate short-circuit current and ground
fault protection.
Greater Convenience and Operational Safety
The controls and status indicators you need most are readily 1600A HPC Switch (Type SHP, Bottom-Feed)
accessible. The flush-mounted handle, ON/OFF buttons, test
receptacle, bell alarm reset buttons with or without lockout Bottom FeedLine terminals at bottom of switch; fuses are
are easily reached and all are double-insulated from live compo- de-energized when switch is in OFF positions. Same size as
nents. And, for added security, a standard padlock device lets you top-feed.
prevent accidental or unauthorized closing of the switch. Quick, Error-Free Installation of Universal Accessories
Drop-in bell alarm, bell alarm with manual reset lockout, shunt trip,
HPC switches, new generation are versatile and designed for
shunt trip with lockout, and undervoltage release install in seconds.
a wide variety of applications including temperature insensitive
No special tools. No switch disassembly. Just slide them into place.
control units, push-to-open and close control, charge-after-close
The modules are universal across all frame sizes and each is
operation, 3 cycle closing, UL listed (file E-51827) field installable
mechanically keyed to its compartment so you make the right
accessories suitable for 50/60 Hz. All accessories and control
connection, every time. These accessories are field installable
wiring are prewired to dedicated, secondary terminal points on
and upgradable.
each switch.
GEs innovative, modular, drop-in accessories provide the ultimate
Features
customer solution for field customization:
High DurabilitySafety of Operation
UL Listed
High-dielectric strength, glass reinforced insulated case.
Accessory combination (one each) shunt trip, shunt trip with
High Interrupting Capability
lockout, undervoltage release, bell alarm (alarm only), bell alarm
Arc chute of unique construction suppresses arcs and cools
with lockout.
gases rapidly, providing quick arc interruption and extended
Rated 12-250 Vdc through 12-240 Vac, continuous duty.
switch life.
High Transient Voltage Withstandability Complete installation in seconds without special tools, switch
Interphase partitions mesh with switch midcover to completely disassembly or adjustment
isolate each pole. The user can select how protective control unit functions, the
Extended Switch Life shunt trip (with or without lockout), and UVR accessories
Preloaded constant pressure pivot eliminates braid whip and interface with the bell alarm and bell alarm with lockout
fraying on high short circuit currents and repeated operations. accessories: An overcurrent, shunt trip, or UVR trip can be set to
Positive ON-OFF Indication actuate the bell alarm or bell alarm with lockout. Any combina-
Green (OFF), Red (ON), provides visual indication regarding the tion of output actions based on inputs can be selected.
position of the switch contacts. Shunt trip and undervoltage trip targets are clearly displayed by
Easy OperationQuick Make the control unit LCD.
Flush-mounted handle, operated 6 times to charge; push button Pre-wired wire harness makes field installation a snap for:
on remote close to close the switch Motor operator with remote charge indicator
Emergency OpenQuick Break Form C auxiliary switches, up to 12-stage maximum
Finger-tip OFF button rapidly opens the switch contacts. Remote close solenoid
Fuse Mounting Bolts for Ease of Mounting Fuses
Padlocking Provisions Standard Additional field-installable accessories including:
Key interlock provision (4 locks maximum)
Product Forms Limited access ON/OFF cover
Top FeedLine terminals at top of switch. Mechanical operations counter
Door interlock

9-2 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Disconnect Switches and Operating Mechanisms Section 9
HPC High-Pressure Contact Switch
Top- or Bottom-Feed
800-4000 Amperes - 600 Vac Max.

HPC Switches with Electric Trip


For use with Ground Break components or for remote tripping. Fuses not included.
For resistance-grounded systems or where zone selective interlocking is required, electric
trip HPC switches with Ground Break system components are recommended.
Source Ampere Control Net Weight, Product
Configuration Rating Voltage Lbs. (Approx.) Number
Top Feed 800A 120-240Vac 75 THPR3608ET1
Top Feed 1200A 120-240Vac 80 THPR3612ET1
Top Feed 1600A 120-240Vac 80 THPR3616ET1
Top Feed 2000A 120-240Vac 165 THPC3620ET1
Top Feed 2500A 120-240Vac 180 THPC3625ET1
Top Feed 3000A 120-240Vac 180 THPC3630ET1
Top Feed 4000A 120-240Vac 505 THPC3640ET1
Top Feed 800A 480-600Vac 75 THPR3608ET2
Top Feed 1200A 480-600Vac 80 THPR3612ET2
Top Feed 1600A 480-600Vac 80 THPR3616ET2
Top Feed 2000A 480-600Vac 165 THPC3620ET2
Top Feed 2500A 480-600Vac 180 THPC3625ET2 Type THPR, 800-1600A


BE H E
Top Feed 3000A 480-600Vac 180 THPC3630ET2 HPC Switch, Top Feed
Top Feed 4000A 480-600Vac 505 THPC3640ET2

SE
Bottom Feed 800A 120-240Vac 75 THPR3608BET1

RS P C
Bottom Feed 1200A 120-240Vac 80 THPR3612BET1
Bottom Feed 1600A 120-240Vac 80 THPR3616BET1
Bottom Feed 2000A 120-240Vac 165 THPC3620BET1
Bottom Feed 2500A 120-240Vac 180 THPC3625BET1

U W ,
Bottom Feed 3000A 120-240Vac 180 THPC3630BET1

N NE TE

.
Bottom Feed 4000A 120-240Vac 505 THPC3640BET1
Bottom Feed 800A 480-600Vac 75 THPR3608BET2
Bottom Feed 1200A 480-600Vac 80 THPR3612BET2
Bottom Feed 1600A 480-600Vac 80 THPR3616BET2
CT R LE
Bottom Feed 2000A 480-600Vac 165 THPC3620BET2
Bottom Feed 2500A 480-600Vac 180 THPC3625BET2
Bottom Feed 3000A 480-600Vac 180 THPC3630BET2
Bottom Feed 4000A 480-600Vac 505 THPC3640BET2
U O O

M
D F S

Manual HPC Switches


O -6 OB

For service or feeder disconnects not requiring ground fault protection. Includes fuse- Type THPR, 800-1600A
mounting hardware and door-catch interlock bracket. Fuses not included. HPC Switch, Bottom Feed
Source Ampere Net Weight Product
Configuration Rating Lbs. (Approx.) Number
PR E 9 :

Top Feed 800A 75 THPR3608


G TE

Top Feed 1200A 80 THPR3612


Top Feed 1600A 80 THPR3616
Top Feed 2000A 165 THPC3620
Top Feed 2500A 180 THPC3625
PA N O

Top Feed 3000A 180 THPC3630


Top Feed 4000A 505 THPC3640
Bottom Feed 800A 75 THPR3608B
Bottom Feed 1200A 80 THPR3612B
Bottom Feed 1600A 80 THPR3616B
Bottom Feed 2000A 165 THPC3620B
Bottom Feed 2500A 180 THPC3625B
Bottom Feed 3000A 180 THPC3630B
Bottom Feed 4000A 505 THPC3640B

Rev. 11/13 www.geindustrial.com BuyLog Catalog 9-3


Data subject to change
without notice
Disconnect Switches and Operating Mechanisms Section 9
HPC High-Pressure Contact Switch
With Integral Ground Fault Devices
800-4000 Amperes - 600 Vac Max.
UL File. No. E-51827

HPC Switches with Integral Ground Fault Protection for Solidly Grounded Systems
Integral Ground Fault with 3-Phase Sensor, Adjustable Pick-up, Adjustable Time-Delay,
Test Function, and Mechanical Ground Fault Indicator
Source Ampere Net Weight Product
Configuration Rating Lbs. (Approx.) Number
Top Feed 800A 105 THPR3608G3T
Top Feed 1200A 105 THPR3612G3T
Top Feed 1600A 105 THPR3616G3T
Top Feed 2000A 195 THPC3620G3T
Top Feed 2500A 210 THPC3625G3T
Top Feed 3000A 210 THPC3630G3T
Top Feed 4000A 540 THPC3640G3T
Bottom Feed 800A 105 THPR3608BG3T
Bottom Feed 1200A 105 THPR3612BG3T
Bottom Feed 1600A 105 THPR3616BG3T
Bottom Feed 2000A 195 THPC3620BG3T HPC Switches with
Bottom Feed 2500A 210 THPC3625BG3T
Bottom Feed 3000A 210 THPC3630BG3T
Integral Ground Fault Protection
Bottom Feed 4000A 540 THPC3640BG3T

.
BE H E
SE
HPC Switches with Integral Ground Fault Alarm only for Solidly Grounded Systems

RS P C
Integral Ground Fault with 3-Phase Sensor, Adjustable Pick-up, Adjustable Time-Delay,
Test Function, and Mechanical Ground Fault Indicator
Source
U W ,Ampere Net Weight Product
N NE TE
Configuration Rating Lbs. (Approx.) Number
Top Feed 800A 105 THPR3608GA3
Top Feed 1200A 105 THPR3612GA3
Top Feed 1600A 105 THPR3616GA3
CT R LE

Top Feed 2000A 195 THPC3620GA3


Top Feed 2500A 210 THPC3625GA3
Top Feed 3000A 210 THPC3630GA3
U O O

Top Feed 4000A 540 THPC3640GA3


Bottom Feed 800A 105 THPR3608BGA3
M
Bottom Feed 1200A 105 THPR3612BGA3
D F S

Bottom Feed 1600A 105 THPR3616BGA3


Bottom Feed 2000A 195 THPC3620BGA3
O -6 OB

Bottom Feed 2500A 210 THPC3625BGA3


Bottom Feed 3000A 210 THPC3630BGA3
Bottom Feed 4000A 540 THPC3640BGA3

Includes fuse-mounting hardware and door-catch interlock bracket. (Fuses not included)
NOTE: The 800-3000 ampere integral ground fault HPC switches can easily be installed in the space occupied by
PR E 9 :

a manual HPC switch of the same ampere rating. The 4000 ampere switch, being 3 inches wider, may require
G TE

some modification.
NOTE: Integral ground fault tripping is accomplished by a low-energy, flux-shifting tripping mechanism and is Integral Ground Fault HPC Pick-up and
not suitable for remote (paralleled) tripping. If remote tripping is required, add suffix RT1 120-240Vac or Delay Time-current Curves
PA N O

RT2 480-600Vac to above product number.

1. Mechanical Indicator protrudes when ground fault occurs.


2. Field Adjustable Ground Fault Trip Point from 200 to 1100 amperes in six steps.
3. Field Adjustable Ground Fault Delay Time min. (0.03 sec.) intermediate (0.20 sec.) and
max. (0.50 sec.) delay time settings.
4. No Trip Test Button permits ground fault system check without tripping switch.
5. Test Button simulates an actual ground fault and will trip switch off unless "No Trip" button is depressed
prior to pushing test button. Ground fault indicator will protrude when system is tested or when actual
ground fault occurs.
Note: Although the integral ground fault function is self-powered, the test function does require an external 120Vac (200 volt amperes nominal)
control power source.

9-4 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Disconnect Switches and Operating Mechanisms Section 9
HPC High-Pressure Contact Switch (continued)
With Integral Ground Fault Devices
800-4000 Amperes
600 Vac Max.
UL File. No. E-51827

Neutral Current (800: 1 ratio) Sensors


Inside Core Thermal Rating Weight Product
Dimensions Construction (Amperes) (Lbs.) Number
2.5 Dia. Solid 1600 3 TGS0002
5 Dia. Solid 2500 4 TGS0005
8 Dia. Solid 3000 7 TGS0008
4 x 8 Split 4000 15 TGS0408
8 x 8 Split 4000 25 TGS0808

TI FO 2 UF NA TS
L A 1 TO A N I G I A R
O R 01 A L
S. E . -
AL -2 R M R P
Neutral Current Sensor - Solid

N N 4 C
ST E 9 IO ES O NT
IN G PR H OR E

W
PA D T C F E M
E E I D C
SE UR SW SE L A
EP

Neutral Current Sensor - Split


PC Y R
U
H NL E:
O T
,
O

Rev. 11/13 www.geindustrial.com BuyLog Catalog 9-5


Data subject to change
without notice
Page Updated 08 / 2016

Disconnect Switches and Operating Mechanisms Section 9


HPC, New Generation High-Pressure Contact Switch
HPC Switch, New Generation, Nomenclature System

HPC Switch, New Generation, Nomenclature

SH P R T 3 X 3 N L 0 0 0 8 1
Char 1-3 Char 4 Char 5 Char 6 Char 7 Char 8 Char 9 Char 10 Char 11 Char 12 Char 13 Char 14 Char 15

Auxiliary Switch,
Fusible Switch Trimplate
SHP = HPC 1 = 4-240V, None
New Generation

Closing Solenoid,
Frame Size
Door Interlock, Counter
R = Small Frame
8 = None, Yes, None

Feed
T = Top Electric Operator, Push Button Cover,
Hidden On
Frame Rating 0 = None, None, None
3 = 800A

Metering, RELT, Communication, Relays, ZSI Undervoltage Release, Blown Fuse Provision
X = Metering-Current, RELT-None, 0 = None
Communication- None, Relays- None, ZSI- None

Bell Alarm, Bell Alarm with Lock Out, Kirk Key Protection
TU Protection
0 = None, None, None
3 = Ground Fault

Switch Rating Shunt Trip/Blown Fuse Provision


N = 800A L = 120Vac/125Vdc Lock Out

Characters 1, 2, 3 Fusible Switch Character 7 Metering, RELT, Communication, Relays, ZSI


Character 1, 2, 3 Metering RELT Comm Relays ZSI Character 7
HPC, New Generation SHP Current None None None None X
Current RELT None None None A
Current RELT Modbus None None B
Characters 4 Frame Size Current None Modbus None None C
Adv & WFC RELT Modbus None None E
Character 4
Adv & WFC None Modbus None None F
Small (800A - 1600A) R
Adv & WFC RELT Modbus Yes None H
Large (2000A - 4000A) C
Adv & WFC None Modbus Yes None J
Long (42 4000A w/ GF, Retrofill only) L
Current None None None G K
Current RELT None None G L
Character 5 Feed Current RELT Modbus Yes G M
Character 5 Current None Modbus Yes G N
Top T Adv & WFC RELT Modbus None G Q
Bottom B Adv & WFC None Modbus None G R
Adv & WFC RELT Modbus Yes G W
Adv & WFC None Modbus Yes G Y
Character 6 Frame Rating Current None None None G&I Z
Character 6 Current RELT None None G&I 1
800A 3 Current RELT Modbus None G&I 2
1600A 5 Current None Modbus None G 3
2000A 6 Adv & WFC RELT Modbus None G&I 5
2500A 7 Adv & WFC None Modbus None G 6
3000A 8 Adv & WFC RELT Modbus Yes G&I 8
4000A 9 Adv & WFC None Modbus Yes G 9

9-6 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Disconnect Switches and Operating Mechanisms Section 9
HPC, New Generation High-Pressure Contact Switch
HPC Switch, New Generation, Nomenclature System

Character 8 TU Protection Character 11 Bell Alarm, Bell Alarm with Lock Out, Kirk
Character 8 Key Protection (Continued)
Fuse Only X 240 240 4 M
I (Switchable) 1 240 600 4 N
IG (I Switchable) 8 600 None 4 R
IGA (I Switchable) 9 600 240 4 S
IGDA (All Switchable)1 A 600 600 4 T
G 3
GA 4
GDA (All Switchable)1 5
Character 12 Undervoltage Release, Blown Fuse Provision
1G switchable by password only
Undervoltage Release Blown Fuse Provision Character 12
None None 0
Character 9 Switch Rating 24 Vac None 1
Character 9 48 Vac None 2
800A N 120 Vac None 3
1200A R 208 Vac None 4
1600A U 240 Vac None 5
2000A W 480 Vac None 6
2500A 1 600 Vac None 7
3000A 2 12 Vdc None 8
4000A 5 24 Vdc None 9
48 Vdc None A
125 Vdc None B
Character 10 Shunt Trip/ Blown Fuse Provision 250 Vdc None C
120 Vac W
Voltage with Lockout without Lockout Blown Fuse Provision Character 10
208 Vac X
None None 0
240 Vac Y
12 Vdc None H
24 Vac/24 Vdc None J
48 Vac/48 Vdc None K
120 Vac/125 Vdc None L Character 13 Electric Operator, Push Button Cover, Hidden On
208 Vac None M Electric Operator Push Button Cover Hidden On Character 13
240 Vac/250 Vdc None N None None None 0
480 Vac None P 120 Vac None None 1
600 Vac None R 240 Vac None None 2
120 Vac V 24 Vdc None None 3
208 Vac W 48 Vdc None None 4
240 Vac Y 72 Vdc None None 5
12 Vdc None 1 125 Vdc None None 6
24 Vac/24 Vdc None 2 None Yes None 8
48 Vac/48 Vdc None 3 120 Vac Yes None 9
120 Vac/125 Vdc None 4 240 Vac Yes None A
208 Vac None 5 24 Vdc Yes None B
240 Vac/250 Vdc None 6 48 Vdc Yes None C
480 Vac None 7 72 Vdc Yes None D
600 Vac None 8 125 Vdc Yes None E
120 Vac S None None Yes G
208 Vac T 120 Vac None Yes H
240 Vac U 240 Vac None Yes J
24 Vdc None Yes K
48 Vdc None Yes L
72 Vdc None Yes M
Character 11 Bell Alarm, Bell Alarm with Lock Out, Kirk
125 Vdc None Yes N
Key Protection None Yes Yes R
Bell Alarm Bell Alarm with Lock Out Kirk Key Protection Character 11 120 Vac Yes Yes S
None None None 0 240 Vac Yes Yes T
None 240 None 1 24 Vdc Yes Yes U
None 600 None 2 48 Vdc Yes Yes V
240 None None 4 72 Vdc Yes Yes W
240 240 None 5 125 Vdc Yes Yes X
240 600 None 6
600 None None 8
600 240 None 9
600 600 None A
None None 4 G
None 240 4 H
None 600 4 J
240 None 4 L

Rev. 11/13 www.geindustrial.com BuyLog Catalog 9-7


Data subject to change
without notice
Disconnect Switches and Operating Mechanisms Section 9
HPC, New Generation High-Pressure Contact Switch
HPC Switch, New Generation, Nomenclature System

Character 14 Closing Solenoid, Door Interlock, Counter Character 15 Auxiliary Switch, Trimplate
Closing Solenoid Door Interlock Counter Character 14 Auxiliary Switch Trimplate Character 15
None Yes None 8 None None 0
120 Vac Yes None 9 4-240V None 1
240 Vac Yes None A 8-240V None 2
24 Vdc Yes None B 12-240V None 3
48 Vdc Yes None C 4-600V None 4
72 Vdc Yes None D 8-600V None 5
125 Vdc Yes None E None Yes 8
None Yes Yes R 4-240V Yes 9
120 Vac Yes Yes S 8-240V Yes A
240 Vac Yes Yes T 12-240V Yes B
24 Vdc Yes Yes U 4-600V Yes C
48 Vdc Yes Yes V 8-600V Yes D
72 Vdc Yes Yes W
125 Vdc Yes Yes X

HPC Switch, New Generation, Frame Product Numbers

THP R 2 3 6 08 T

Fusible Switch Feed


THP = HPC Switch T = Top
B = Bottom

Frame Size
R = Small Frame (800A-1600A) Switch Rating
C = Large Frame (2000A-4000A) 08 = 800A
L = Long Frame (42 4000A w/ GF, Retrofill only) 12 = 1200A
16 = 1600A
Construction 20 = 2000A
2 = New Generation 25 = 2500A
25 = 2500A
40 = 4000A
Poles
3 = 3 Pole
Voltage
6 = 600V

9-8 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Disconnect Switches and Operating Mechanisms Section 9
HPC, New Generation High-Pressure Contact Switch
Product Number Nomenclature System

Accessory Product Numbers

SP AS 240 AB4 R
HPC Switch Extender
R = Field installable kit
Device Type
Blank = Factory installed
AS = Auxiliary switch1
BAA = Bell alarm, alarm only1 Auxiliary Switch Extender
BAL = Bell alarm with lockout1 AB4 = Auxiliary switch, type AB with 4 elements
COUNTER = Mechanical counter1 AB8 = Auxiliary switch, type AB with 8 elements
DIL = Defeatable door interlock AB12 = Auxiliary switch, type AB with 12 elements
E = Electric operator1
K4 = Kirk key lock (4 maximum)1 Voltage, unless otherwise stated
PBCOVER = Pushbutton cover1 012 = 12 Vdc
RCS = Remote close solenoid1 024 = 24 Vdc
ST = Shunt trip 048 = 48 Vdc
STL = Shunt trip with lockout1 120/125 = 120 Vac or 125 Vdc
UV = Undervoltage release 240/250 = 240 Vac and 250 Vdc
250 = 250 Vdc
480 = 480 Vac
600 = 600 Vac
08 = 800 A 25 = 2500 A
16 = 1600 A 30 = 3000 A
20 = 2000 A 40 = 4000 A

1Device Product Number requires an extender R for field installable kit version only.
NOTE: This information is provided only for use interpreting product numbers. It cannot be used to build product numbers.

Rev. 11/13 www.geindustrial.com BuyLog Catalog 9-9


Data subject to change
without notice
Disconnect Switches and Operating Mechanisms Section 9
HPC , New Generation High-Pressure Contact Switch
EntelliGuard Control Unit Nomenclature

EntelliGuard Control Unit Nomenclature

G F 1 0 8 L W X X X R X X X X
Char 1-2 Char 3 Char 4 & 5 Char 6 & 7 Char 8 Char 9 Char 10 Char 11 Char 12 Char 13 Char 14 Char 15

Control Unit Form


GF = HPC
New Generation

Frame Rating
Reserved
1 = 800A

Sensor Rating
08 = 800A
Reserved
OC and GF Protection Packages
LW = GF Only

Zone Selective Interlocking Reserved


X = None

Advanced Features and Communications Reserved


X = None Selected

Manual/Auto Trip Reset Original Factory or Replacement Control Unit


X = None R = Replacement

Character 1 & 2 EntelliGuard Control Unit Form Character 8 Zone Selective Interlocking
Character 1 & 2 Character 8
HPC, New Generation GF None X
G user selectable Z
Z+IOC user selectable T
Character 3 Frame Ratings
Character 3
Character 9 Advanced Features and Communications
800A 1
1600A 2 Character 9
2000A 3 None Selected X
2500A 4 RELT 1
3000A 5 RELT+Modbus 2
4000A 7 Modbus-Adv Meter+WFC +RELT 6
Note: Use 1600A CT w/ 1200A rating plug for 1200A HPC frame. Modbus-Adv Meter+WFC+RELT+relay 8
Modbus Only (No RELT) A
Adv Metering, Modbus (No RELT) D
Character 4 & 5 Sensor Rating (Amperes) Adv Metering, Modbus, Relays (No RELT) E
Character 4 & 5
800A 08
1600A 16 Character 10 Manual/Auto Trip Reset
2000A 20 Character 10
2500A 25 None X
3000A 30
4000A 40
Character 11 Original Factory or Replacement Control Unit
Character 6 & 7 OC and GF Protection Packages Character 11
Factory F
Character 6 & 7 Replacement R
Fuse Only LZ
I (Switchable) S1
IG (I Switchable) S2
IGA (I Switchable) S3
IGDA (All Switchable)1 S4
GDA (All Switchable)1 S5
G LW
GA LY
1G switchable by password only

9-10 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Disconnect Switches and Operating Mechanisms Section 9
HPC High-Pressure Contact Switch
Application Information
Outlines and Dimensions

Application Information HPC Switches with Integral Ground Fault Protection


Weights are for units with integrally mounted three-phase sensor.
Ampere Outline Approx. Shipping Approx. Net Connectors
Rating Drawing Weight (Lbs.) Weight (Lbs.) Product Number
800A 139C4219 115 105 1
TS20FCA
2000A 139C4114 sh 2 220 195
(Optional)
TS25FCA
2500A 139C4114 sh 3 235 210
(Optional)
TS30FCA
3000A 139C4114 sh 3 235 210
(Optional)
1-TS40LFCA


4000A 139C4114 sh 6 464 540
5-TS40FCA

IT NE E TU HP D
CH W P R C
Application Information HPC Switches without Integral Ground Fault Protection

S W R . FA O R A N
Data in the table below pertains to Type HPC switches without integral ground devices.

G D
Ampere Outline Approx. Shipping Approx. Net Connectors
Rating Drawing Weight (Lbs.) Weight (Lbs.) Product Number

E
800A 139C4219 85 75 1

N
TS20FCA
2000A 139C4114 sh 2 190 165

E
(Optional)

PC 2 0 N A O
2500A 139C4114 sh 3 205 180
TS25FCA
(Optional)
TS30FCA
H - 1 2 A AT T I
3000A 139C4114 sh 3 205 180
(Optional)

A
4000A
F 139C4114 sh 6 429 505
1-TS40LFCA

C
TO M D A

5-TS40FCA
R ES S LIC

Minimum OEM Enclosure Dimensions and Ventilation Requirements 2


Min Volume A Min Ventilation3 B Min Line F Min to Ground
Ampere

E
(Cubic Top and Bottom to Ground C Min Height D Min Width E Mounting4 or Insulation
U
Rating Inches) (Square Inches) (Inches) (Inches) (Inches) Depth (Inches) (Inches)
S
IO CH ION PP

.
800A 8400 23 2 28 25 8.66 3.5
1200A-1600A 11100 63 2 30 25 8.66 3.5

ES
2000A 28000 63 2 40 25 9.38 3
2500A 28000 172 2 40 25 9.38 3
4
PR IT S : A

3000A 30000 172 2 40 25 9.38 3


4000A 54650 189 9 52 30 11.12 3
1

Switch Dimensions (For Estimating Only) 5


SW E TE

Ampere Rating6 Dimension A Dimension B Dimension C Dimension D Dimension E Dimension F


O

800 24.31 18.00 8.66 7.69 4.96


IM O

1200, 1600 26.72 18.00 8.66 7.69 4.96


F
N

2000, 2500, 3000 36.00 19.25 9.38 8.25 15.56


12.75 (B)
D N

4000 40.00 22.387 11.12 9.24 18.19 Minimum OEM Enclosure Dimensions
7.75 (A & C)
and Ventilation Requirements
Note: For dimensions of neutral current sensor to be used with integral ground fault switches, page 9-34.
1See page 9-33 for optional connectors.
2Dimensions are minimum requirements and do not represent enclosures on page 9-22.
3Ventilating openings can be in alternate locations but must provide equivalent ventilating areas.
9

4For switches with integrally mounted three-phase Ground Fault current sensor (Product Numbers with suffix G3T,
G3R, GA3, BG3T, BGA3, BG3R) add 1.62 inch to dimension E.
5For complete switch dimensions order outline drawings from application information above.
6For Product Numbers with suffix B (bottom-feed), invert drawing.
7With integral ground fault, overall width is 24 inches.

Switch Dimensions
(For Estimating Only)

Rev. 11/13 www.geindustrial.com BuyLog Catalog 9-11


Data subject to change
without notice
Disconnect Switches and Operating Mechanisms Section 9
HPC , New Generation High-Pressure Contact Switch
Application Information
Outlines and Dimensions

Application Information HPC Switches, New Generation


Ampere Outline
Rating Feed Drawing
800A Top 10112083P1
800A Bottom 10112083P2
1200/1600A Top 10112083P3
1200/1600A Bottom 10112083P4
2000A Top 10112083P5
2000A Bottom 10112083P6
2500/3000A Top 10112083P7
2500/3000A Bottom 10112083P8
4000A Top 10112083P11
4000A Bottom 10112083P12

Weights HPC Switches, New Generation


Frame Operation Weight
Rating Type (lb)
800A Manual 81
800A Electrical 90
1200/1600A Manual 95
1200/1600A Electrical 104
2000A Manual 110
2000A Electrical 119
2500/3000A Manual 210
2500/3000A Electrical 219
4000A Manual 400
4000A Electrical 409

Enclosure Dimensions, Volume and Ventilation Requirements


Min Volume A Min Ventilation B Min Line F Min to Ground
Ampere (Cubic Top and Bottom1 to Ground C Min Height D Min Width E Mounting or Insulation
Rating Inches) (Square Inches) (Inches) (Inches) (Inches) Depth (Inches) (Inches)
800A 6062 23 2 28 25 8.66 3.5
1200A-1600A 6495 63 2 30 25 8.66 3.5
2000A 9380 63 2 40 25 9.38 3
2500A 9380 172 2 40 25 9.38 3
3000A 9380 172 2 40 25 9.38 3
4000A 17347 189 9 52 30 11.12 3

Note: For dimensions of neutral current sensor to be used with integral ground fault switches,
see outline drawings: 139C5016SH1 & SH2 (TSVG types) and 10112973P1 (SSVG types).
1Ventilating openings can be in alternate location but must provide equivalent ventilating areas.

9-12 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Disconnect Switches and Operating Mechanisms Section 9
HPC , New Generation High-Pressure Contact Switch
HPC Switch, New Generation

How to Order
1. Determine your new HPC 15-digit part number by using the Configurator (contact your authorized GE Distributor) and refer to the
Buylog for complete list of options.

2. Check EliteNet for price and availability (For access to EliteNet, contact your authorized GE Distributor). Note: Because of multiple
possible combinations, only product numbers that have been ordered are in EliteNet. If the product number you are interested in is
not in EliteNet, email the request to GE.1STOP_REPLY@GE.com to add it to the system.

3. Once the product number is loaded, the order can be placed via EliteNet.

4. Note: Neutral CTs and T-Studs are ordered separately from the 15-digit product number.

Rev. 11/13 www.geindustrial.com BuyLog Catalog 9-13


Data subject to change
without notice
Disconnect Switches and Operating Mechanisms Section 9
HPC , New Generation High-Pressure Contact Switch
Accessories - HPC Switch, New Generation
All devices UL Listed for factory or field installation except where noted.

Accessories
The complete line of new generation HPC switch accessories may be either factory or
field installed to meet user needs. The electronic shunt trip, the bell alarm, the bell alarm
with mechanical lockout, and the undervoltage release modules are drop-in from the
front of the switch, interchangeable across all frames, and require no field internal wiring
or switch disassembly. Auxiliary switch modules are available in groups of 4, 8 or 12,
NO/NC single-pole, double-throw (SPDT) switches. Their installation simply involves
removal of switch cover, installation of the switch module, routing of wiring and installa-
tion of the pre-wired terminal block and re-installation of the cover. Auxiliary switches
are also interchangeable across all new geneation HPC switch frames.

Electrical Operator
The electrical operator mounts inside the front cover of the manually operated switch.
This accessory can be added to any new generation HPC switch in the factory or the
field to provide electrical spring charging and charge indication. For remote closing, the
remote close solenoid must be ordered separately. All switches are prewired to dedi-
cated secondary terminals for easy field installation. When electrical operation is used,
either a shunt trip or an undervoltage release must be ordered separately.

Ratings Ratings Field Installable Factory Installed


Vac Vdc Product Number Product Number
120 SPE120R SPE120
240 SPE240R SPE240
24 SPE024R SPE024
48 SPE048R SPE048
72 SPE072R SPE072
125 SPE125R SPE125 Electrical Operator

Remote Close Solenoid


This accessory provides an electrically operated solenoid which, when energized, closes
the switch. It is suitable for control interlock schemes in which manual closing capability
would not be convenient or desirable. The switch is provided with a manual close button,
which can be replaced by the Hidden "ON" Button accessory and/or sealed using the
Limited Access Pushbutton Cover accessory. The remote close accessory is continuously
rated and has an anti-pump feature, which prevents a motor operated switch from
repeatedly closing into a fault. Closing control voltage must be removed and re-applied for
each switch closure.

Ratings Ratings Field Installable Factory Installed


Vac Vdc Product Number Product Number

120 SPRCS120R SPRCS120


240 SPRCS240R SPRCS240
24 SPRCS024R SPRCS024
48 SPRCS048R SPRCS048 Remote Close Solenoid
72 SPRCS072R SPRCS072
125 SPRCS125R SPRCS125

9-14 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Disconnect Switches and Operating Mechanisms Section 9
HPC , New Generation High-Pressure Contact Switch
Accessories - HPC Switch, New Generation
All devices UL Listed for factory or field installation except where noted.

Shunt Trip
The shunt trip accessory is an electronic module, which provides remote control capabil-
ity to open the switch. When activated, the shunt trip module sends a signal to the
control unit to open the switch. This allows the control unit to record, display, distinguish
and communicate that the opening event was initiated by the shunt trip device. The
shunt trip is continuously rated and requires no cut-off switch. When energized, the
shunt trip supplies +24Vdc power to the control unit to power the display.
Ratings Ratings Field Installable Factory Installed
Vac Vdc Product Number Product Number
12 SPST012R SPST012
24 24 SPST024R SPST024
48 48 SPST048R SPST048
120 125 SPST120R SPST120
208 SPST208R SPST208
240 250 SPST240R SPST240
Shunt Trip Module
480 SPST480R1 SPST4801
600 SPST600R1 SPST6001
1Kit contains externally mounted transformer.

Shunt Trip with Lockout Module


The shunt trip with lockout is identical to the regular shunt trip, but when energized,
it will also prevent closure of an "open" switch by mechanically blocking both manual
and electrical closing. When energized, the closing springs will not discharge, the
movable contacts will not move; the contacts are "kiss free."
Ratings Ratings Field Installable Factory Installed
Vac Vdc Product Number Product Number
12 SPSTL012R SPSTL012
24 24 SPSTL024R SPSTL024
48 48 SPSTL048R SPSTL048
120 125 SPSTL120R SPSTL120
208 SPSTL208R SPSTL208
240 250 SPSTL240R SPSTL240
480 SPSTL480R1 SPSTL4801
600 SPSTL600R1 SPSTL6001
1Kit contains externally mounted transformer.

Undervoltage Release Module


The undervoltage release is an electronic module used to open the switch when the
monitored voltage drops below 35-60% of its rated value. The undervoltage release
"resets" when the monitored voltage is re-established allowing the switch to re-close
(the sealing voltage of the UVR is 60-85% of its rated voltage).
An undervoltage release trip operation is produced by the GTU control unit in response
to a signal from the undervoltage release module. This allows the control unit to record,
display, distinguish and communicate that the switch opening event was due to under-
voltage release. Operation of the undervoltage release module will prevent switch
contact closure, i.e. "kiss-free" operation. When energized, the undervoltage release
supplies +24 Vdc power to the control unit to power the display.
Ratings Ratings Field Installable Factory Installed
Vac Vdc Product Number Product Number
24 SPUV024ACR SPUV024AC
48 SPUV048ACR SPUV048AC Undervoltage Release Module
120 SPUV120ACR SPUV120AC
208 SPUV208ACR SPUV208AC
240 SPUV240ACR SPUV240AC
480 SPUV480ACR1 SPUV480AC1
600 SPUV600ACR1 SPUV600AC1
12 SPUV012DCR SPUV012DC
24 SPUV024DCR SPUV024DC
48 SPUV048DCR SPUV048DC
125 SPUV125DCR SPUV125DC
250 SPUV250DCR SPUV250DC
1Kit contains externally mounted transformer.

Rev. 11/13 www.geindustrial.com BuyLog Catalog 9-15


Data subject to change
without notice
Section Updated 08 / 2016
Disconnect Switches and Operating Mechanisms Section 9
HPC , New Generation High-Pressure Contact Switch
Accessories - HPC Switch, New Generation
All devices UL Listed for factory or field installation except where noted.

Blown Fuse Protector


The Blown Fuse Protector (factory installed) is an accessory which includes components
mounted on and external to the new HPC switch. Control wiring is connected from one
end of each fuse mounting bus-strap to a 6 pt. terminal block mounted on the side of
the new HPC switch. A shunt trip Lockout device or UVR trip device is included based
on the product numbers below for remote opening of the new HPC switch in the event
of a blown fuse to avoid single phasing.
The accessory also includes a pin-wheel style Blown Fuse Detector equipped with 3 trig-
ger fuses + 1 spare. Wiring from the pin-wheel device to the new HPC switch is the
responsibility of the switchboard builder.

Ratings Factory Installed Field Installable Trip Accessory


Vac Product Number Product Number1 Provided
120 BFSPSTL120AC BFSPSTL120ACR SPSTL120
208 BFSPSTL208AC BFSPSTL208ACR SPSTL208
240 BFSPSTL240AC BFSPSTL240ACR SPSTL240
120 BFSPUV120AC BFSPUV120ACR SPUV120AC
208 BFSPUV208AC BFSPUV208ACR SPUV208AC
240 BFSPUV240AC BFSPUV240ACR SPUV240AC
120 BFSPST120AC BFSPST120ACR SPST120
208 BFSPST208AC BFSPST208ACR SPST208
240 BFSPST240AC BFSPST240ACR SPST240
1For field installable kits only, the Pin wheel style Blown Fuse Detector is not included due to UL accessory listing
requirements.
Source the Boltswitch PW-2 Blown Fuse Detector separately and follow that manufacturers instructions for
mounting and use.

Bell Alarm (Alarm Only)


The bell alarm module is used to signal switch "tripped" status to other accessories (e.g.,
external alarm devices, indicating lights, relays, or logic circuits) for remote indication
and interlocking functions. The bell alarm response is configurable by means of rear-
mounted DIP switches on the control unit. The bell alarm can be made to operate in
response to an overcurrent (including ground fault) or protective relay trip and/or a
shunt trip operation, and/or operation of the undervoltage release module. It is not
actuated as a result of normal switch "ON/OFF" operation.
This module provides a visual, mechanical pop-out target, which protrudes through the
face of the switch door when it operates. The bell alarm may be reset manually by
depressing the mechanical target, or automatically by closing the switch.
The bell alarm is provided with one SPDT switch with control power duty contacts as
shown in the auxiliary switch accessories.

Ratings Ratings Field Installable Factory Installed


Vac Vdc Product Number Product Number
240 125-250 SPBAA240R SPBAA240
Bell (Alarm Only)
600 125-250 SPBAA600R2 SPBAA6002
2600 Vac module not UL Listed.

9-16 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Disconnect Switches and Operating Mechanisms Section 9
HPC , New Generation High-Pressure Contact Switch
Accessories - HPC Switch, New Generation
All devices UL Listed for factory or field installation except where noted.

Bell Alarm With Lockout


The bell alarm with lockout module combines both the bell alarm and a manual lockout
function. The bell alarm switch operates identically to the standard bell alarm module,
except that the mechanical pop-out target must be manually reset before the switch
can be closed.
Operation of the bell alarm with lockout module can be independently set by means
of setting the DIP switches at the rear of the control unit. Current rating of the single
SPDT switch is identical to the auxiliary switch accessories.

Ratings Ratings Field Installable Factory Installed


Vac Vdc Product Number Product Number
240 125-250 SPBAL240R SPBAL240
600 125-250 SPBAL600R1 SPBAL6001
Bell Alarm with Mechanical Reset Lockout
1600 Vac module not UL Listed.

Auxiliary Switch
An auxiliary switch signals the HPC switchs primary contact position (i.e., OPEN or
CLOSED) to other devices, such as indicating lights, relays or logic circuits. This enables
the user to provide remote indication, interlocking or control operations as a function of
HPC switch primary contact position. The auxiliary switch operation is independent of
the method by which the HPC switch is opened or closed. The auxiliary switch does not
distinguish between a "tripped" or "open" condition. The auxiliary switch contacts follow
the main HPC switch contacts on opening and precede them on closing.
Auxiliary switch modules are available with 4, 8 or 12 NO/NC (SPDT) switches for control
power duty ac/dc ratings. When ordered for field installation, an auxiliary switch module
comes pre-wired to its own terminal board, which mounts with one screw to the left of
the HPC switch. All switch ratings are 6A at 120V-600 Vac, 1/2A at 125 Vdc and 1/4A at
250 Vdc.
Auxiliary Switch with
Pre-wired Secondary Terminals
No. of SPDT
Ratings Ratings Switch Elements Field Installable Factory Installed
Vac Vdc (Contacts) Product Number Product Number
240 125-250 4 SPAS240AB4R SPAS240AB4
240 125-250 8 SPAS240AB8R SPAS240AB8
240 125-250 12 SPAS240AB12R SPAS240AB12
600 125-250 4 SPAS600AB4R1 SPAS600AB41
600 125-250 8 SPAS600AB8R1 SPAS600AB81
1600 Vac module not UL Listed.

Rev. 11/13 www.geindustrial.com BuyLog Catalog 9-17


Data subject to change
without notice
Disconnect Switches and Operating Mechanisms Section 9
HPC , New Generation High-Pressure Contact Switch
Accessories - HPC Switch, New Generation
All devices UL Listed for factory or field installation except where noted.

Mechanical Operations Counter


The mechanical operations counter is mounted behind the front cover of the switch. It is
viewable through a rectangular knockout window opening in the switch cover. It is a
five-digit, non-resettable counter, which is actuated each time the switch is opened by
any means.
Field Installed Factory Installed
Product Number Product Number
SPCOUNTERR SPCOUNTER
Mechanical Operations Counter

Limited Access Pushbutton Cover


This accessory limits access to "ON/OFF" control of a switch to authorized personnel. The
pushbutton cover accessory consists of transparent hinged covers that can be individu-
ally sealed to the limited access assembly. Both the "ON" and "OFF" buttons can be pilot
drilled to allow use of a 1/8" rod to operate either one or both pushbuttons.
Field Installed Factory Installed
Product Number Product Number
SPPBCOVERR SPPBCOVER

Limited access pushbutton cover

Hidden "ON" Button


The hidden "ON" button is assembled to the mechanism behind an unlabeled, false
pushbutton. Manual closing of the switch can only be performed by means of a small
diameter rod. This accessory is used to limit access to the manual "ON" control to
authorized personnel.
Field Installed Factory Installed
Product Number Product Number
SPPBNONR SPPBNON

Activating the switch closing


mechanism through the hole in the
Hidden ON Button

Maintenance/Repair Parts
Description Product Number
Top Cover and Rating Labels SPBIICOVER1
Visible On Button Conversion SPPBRONR
1Special handling and order entry required to preserve UL Listing of switch.
Contact Post Sale Service for additional details of special process.

9-18 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Disconnect Switches and Operating Mechanisms Section 9
HPC , New Generation High-Pressure Contact Switch
Accessories - HPC Switch, New Generation
All devices UL Listed for factory or field installation except where noted.

Key Interlock Provisions


The key interlock provision enables the user to mount a one- to four-cylinder, narrow-
faced, Kirk-type FN or Superior customer-supplied lock on the face of the switch. This
accessory provides mounting for key interlocks that are furnished by the customer. The
key interlock provision works in conjunction with the padlock provision. The key interlock
extends a lever through the padlock hasp when the key is turned to the key removal or
bolt extended position. Additionally, the accessory provides a hasp for mounting three
padlocks with 1/4" to 3/8" diameter shanks.

Key Interlock Reference Table


Kirk Key Lock Superior
Product Number Number of Locks Product Number Product Number
SPK4 1 KFN000011 S105827Y
SPK4 2 KFN000021 S105828Y
SPK4 3 KFN000031 S105829Y
SPK4 4 KFN000041 S105827-4Y
Key Interlock Kit (lock not included)
1Final digit may be 0, 1, 2 or 3 depending on number of key removal positions.

Product Numbers, Key Interlock Provisions


Circuit Breaker Number of Field Installed Factory Installed
Envelope Size (Amps) Key Locks Product Number Product Number
All 1 to 4 SPK4R SPK4

Door Interlock
The door interlock provides interlocking of the switch compartments hinged door so
that the switch must be in the "OFF" position before the door can be opened. The door
interlock is defeatable with a small tool to allow authorized access.

Field Installed Factory Installed


Product Number Product Number
SPDILR SPDIL

Padlock Provisions (Standard) Door Interlock


Padlocking provisions are standard on all new generation HPC switches. When the
switch is in the open position, and the padlock hasp is raised at least 1/4", the switch
cannot be closed mechanically or electrically. The hasp accepts up to three padlocks
with 1/4" to 3/8" diameter shanks.

Rev. 11/13 www.geindustrial.com BuyLog Catalog 9-19


Data subject to change
without notice
Disconnect Switches and Operating Mechanisms Section 9
HPC, New Generation High-Pressure Contact Switch
Accessories
UL Listed

Adapter Kits Lug Kits (For use with adapter only)


(Accepts either lugs, bus, or Anderson VCEL VersaCrimp) (Accepts either lugs, bus, or Anderson VCEL VersaCrimp)
For Line or Load end of 3-pole switch. One per Product Number; standard carton contains:
6TPLUG106;
Product
3TPLUG108.
Ampere Rating Number
800A THPCLUGA08 No. of Lugs per Pole Wire Range Product
1200A Ampere Rating Line or Load End Cu/Al Number
TPLUGA16
1600A 800A 3 (1) #2-600 kcmil or
TPLUG106
(2) 1/0-250 kcmil
3 (1) 3/0-800 kcmil Cu or
800A TPLUG108
Field Installed Lugs Kits 800-1600 Ampere 6 (1) 250-800 kcmil Al

SwitchesDirect Mounting
Field installed only. Kits consist of lugs and hardware for direct Trimplate
Factory Installed Field Installable
mounting to switch terminal straps (multiple-hole tang lugs) or lugs Product Number Product Number
for mounting to 800 ampere terminal adapter kit. Order three kits SPTRIMPLATE SPTRIMPLATER
for three-pole line or load end. For 1600-ampere, copper conduc-
tors must be used.
Accessory Wire Range Product
Ampere Rating Type Cu/Al Number
Lug Kit Line
800A (3) 300-750 THPCLUG308
& Lug Kit Load
1200A, 1600A Lug Kit Line (4) 500-800 kcmil TPLUG408
1200A, 1600A Lug Kit Load (4) 500-800 kcmil THPCLUG408

Field Installed Lugs Kits 2000-4000 Ampere


SwitchesDirect Mounting
Field installed only. To terminate line and load cables, must be
used in conjunction with bus-connection adapter on page 9-20
(T Studs). Each lug kit includes lugs, straps and hardware for three-
phase line or load connections. Each cable lug accommodates
13/0 Cu or 250 kcmil Al to 800 kcmil Cu-Al. Accepts Anderson
VersaCrimp when lugs are removed from straps.
No. of Lugs per Pole Product
Ampere Rating Line or Load End Number
2000A 6 TSLUG20
2500A 7 TSLUG25
3000A 9 TSLUG30
4000A 11 TSLUG40

Field Installed T Studs


Field installed only. May be used to adapt line and load terminals
of switch to vertical or horizontal bus arrangements. Three
required for line or load connections on three-phase bus. Accepts
either lugs, bolts, or Anderson VCEL VersaCrimp.
Basic Switch Product
Rating (Amperes) Number
800 THPC08FCA1
1200-1600 TP16FCA
2000 TS20FCA
2500 TS25FCA
3000 TS30FCA
TS40FCA2
4000
TS40LFCA3
1For vertical bussing only.
2For load terminals and left/right line terminals.
3For center pole, line terminal.

9-20 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Disconnect Switches and Operating Mechanisms Section 9
HPC , New Generation High-Pressure Contact Switch
Accessories - HPC Switch, New Generation

Neutral Current Sensors1


HPC Switch Neutral Sensor
HPC Switch Frame Sensor Rating Rating or Tap Product
(Amperes) (Amperes) Settings (Amperes) Number
200 200 TSVG302
800 400 400/200 TSVG304A
400 600/3002 TSVG306A
800-1600 800 800/400 TSVG308A
1000 800/4002 TSVG808A
1000 1000/500 TSVG810A
1600
1600 1200/6002 TSVG812A
1600 1600/1000 TSVG816A
2000 2000 2000/1000 TSVG820A
1000 800/4002 TSVG808A
1000 1000/500 TSVG810A TSVG Neutral Current Sensor
1000 1200/6002 TSVG812A
3000 1000 1600/10002 TSVG816A
2000 2000/1200 TSVG820A
2500 2500/1800 TSVG825A
3000 3000/2400 TSVG830A
4000 4000 4000/3000 TSVG940A
1Match neutral current sensor rating (or tap setting) to new HPC switch
sensor rating.
2For use with multiple source ground fault protection schemes. Rating does
not match EntelliGuard TU frame sensor.

Neutral Current Sensors1


HPC Switch HPC Switch Neutral Sensor Product Inside
Frame Sensor Rating Rating or Tap Number of Diameter
(Amperes) (Amperes) Settings (Amperes) Window Sensor (inches)
800 800 800/400 SSVG808W 4.25
12003 2000/1200 SSVG820W 5.63
1200
16003 1600/1000 SSVG816W 5.63
1600 1600 1600/1000 SSVG816W 5.63
2000 2000 2000/12003 SSVG820W 5.63
2500 2500 2500/1800 SSVG825W 5.63
3000 3000 4000/3000 SSVG940W 6.50
4000 4000 4000/3000 SSVG940W 6.50
1Match neutral current sensor rating (or tap setting) to new HPC Switch
sensor rating.
3At time of initial product release, the 1200A new HPC Switch was using 1600A
installed sensors and a 1200A rating plug. Later models may or may not use
1200A phase sensors. Match Neutral sensor tap to HPC sensor rating. SSVG Neutral Current Sensors

Rev. 11/13 www.geindustrial.com BuyLog Catalog 9-21


Data subject to change
without notice
Disconnect Switches and Operating Mechanisms Section 9
HPC , New Generation High-Pressure Contact Switch
HPC Switch, New Generation

Reference Publications
Auxiliary Switch Module GEH6274
Bell Alarm Alarm Only GEH6275
Door Interlock GEH6276
Lugs & Adapters for 8002000 A Frames GEH4546
Bell Alarm with Lockout GEH6278
Key Interlock Mounting Provision GEH6279
Mechanical Counter GEH6280
Motor Operator Mechanism GEH6281
Push Button Cover GEH6282
Remote Close GEH6283
Shunt Trip and Shunt Trip with Lockout (except 480 and 600 Vac) GEH6284
Shunt Trip and Shunt Trip with Lockout, 480 & 600 Vac GEH6519
Undervoltage Release (except 480 and 600 Vac) GEH6285
Undervoltage Release, 480 & 600 Vac GEH6520
Instructions, HPC Heat Sink Installation DEH41694
Instructions, HPC Blown Fuse Protector DEH41695
EntelliGuard TU Trip Unit DEH4567
HPC Switches, New Generation, Users Guide DEH41689
Time Current Curves HPC Switches, New Generation, Ground Fault DES121
Time Current Curves HPC Switches,
New Generation, Adjustable Selective Instantaneous Trip,
Reduced Energy Let-Through (RELT) DES-122
HPC Switches, New Generation, Instantaneous Protection Guide DEE-715

9-22 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Disconnect Switches and Operating Mechanisms Section 9
Premium Duty QMW, Heavy Duty QMR
Individual Components
30-200 Amperes
240, 480, 600 Vac, 250 Vdc

Product Description
QMR and QMW switches (30-200 amperes), fuse and no-fuse kits
are UL Recognized Components, File E-36152, and UL Recognized
to Canadian safety requirements under the Component Recognition
Program of Underwriters Laboratories Inc.
The 30-200 ampere fusible switches are UL Recognized for use
on circuits capable of delivering not more than 200,000 rms
symmetrical amperes at 240 or 600Vac when fused with Class R
rated size fuses. Refer to the table 7-3 for the appropriate Class R
Fusing Kit. They are suitable for use with Type STDA flange handles
and variable depth operating mechanisms on page 9-28.

QMW Premium Heavy-Duty Switch


(with Fuse Clips from Fuse Kit)

Basic Switches - Premium Duty (QMW) and Heavy Duty (QMR)


Interrupting Rating Amperes Symmetrical
Duty Type Ampere Rating 600Vac, 3-phase Product Number
Premium Duty QMW 30A 950 THMC311
Premium Duty QMW 60A 1700 THMC321
Premium Duty QMW 100A 1800 THMC331
Premium Duty QMW 200A 3600 THMC34
Heavy Duty QMR 30A 420 THMS311
Heavy Duty QMR 60A 900 THMS321
Heavy Duty QMR 100A 1700 THMS331
Heavy Duty QMR 200A 3400 THMS34

Handle Operator: Order from pages 9-28 or 9-29.


1Specify special screw kit if load risers are to be fastened from underside of base. Two screws required per switch; 10 screws in each product number THMC1 kit,

Rev. 11/13 www.geindustrial.com BuyLog Catalog 9-23


Data subject to change
without notice
Disconnect Switches and Operating Mechanisms Section 9
Premium Duty QMW, Heavy Duty QMR (continued)
Individual Components
30-200 Amperes
240, 480, 600 Vac, 250 Vdc

Fuse and No-Fuse Kits Horsepower Ratings 3-pole


HP Rating, HP Rating, HP Rating, HP Rating, HP Rating, HP Rating,
AC, 3-Phase, AC, 3-Phase, AC, 3-Phase, AC, 3-Phase, AC, 3-Phase, AC, 3-Phase,
Product Description NEC Std. NEC Std. NEC Std. Time-Delay Time-Delay Time-Delay HP Rating, HP Rating,
Number of Kit Fuse @ 240Vac Fuse @ 480Vac Fuse @ 600Vac Fuse @ 240Vac Fuse @ 480Vac Fuse @ 600Vac 125Vdc 250Vdc
THMC3100 No Fuse 7.5 20 25 3 5
THMC3200 No Fuse 20 40 50 5 10
THMC3300 No Fuse 30 60 75 20
THMC3400 No Fuse 60 125 150 40
THMC3121 30A, 240Vac/250Vdc 3 7.5 3 5
THMC3222 60A, 240Vac/250Vdc 5 15 5 10
THMC3161 30A, 600Vac 5 7.5 15 20 3 5
THMC3262 60A, 600Vac 15 20 40 50 5 10
THMC3363 100A, 240Vac/250Vdc 10 25 30 30 60 75 20
100A, 600Vac
THMC3364 200 A, 600Vac 25 50 60
THMC3464 200A, 240Vac/250Vdc 25 50 60 60 125 150 40
200A, 600Vac
THMC3465 400A, 600Vac 50 100 125

Fuse and No-Fuse Kits (Includes load block, clips, and lugs)
Product Switch
Number Description of Kit Product Number Fuse Type No. of Poles Lug Wire Size
THMC31002 No Fuse THMC31 or THMS31 No Fuse 3 Wire Keeper Term.
for #14-8 CU
THMC3200 No Fuse THMC32 or THMS32 No Fuse 3 CU 14-2 AL 12-2
THMC3300 No Fuse THMC33 or THMS33 No Fuse 3 CU 14-0 AL 12-0
THMC3400 No Fuse THMC34 or THMS34 No Fuse 3 6-250 kcmil CU-AL
THMC31211 30A, 240Vac/250Vdc THMC31 or THMS31 NEC Standard 3 Wire Keeper Term.
for #14-8 CU
THMC32221 60A, 240Vac/250Vdc THMC31 or THMS31 NEC Standard 3 Wire Keeper Term.
for #14-8 CU
THMC31611 30A, 600Vac HMC31 or THMS31 NEC Standard 3 TWire Keeper Term.
and Class J for #14-8 CU
THMC32621 60A, 600Vac THMC31 or THMS31 NEC Standard 3 Wire Keeper Term.
and Class J for #14-8 CU
THMC3363 100A, 240Vac/250Vdc THMC32 or THMS32 NEC Standard 3 CU 14-2 AL 12-2
100A, 600Vac and Class J
THMC3364 200A, 600Vac THMC33 or THMS33 NEC Standard 3 CU 14-0 AL 12-0
and Class J
THMC3464 200A, 240Vac/250Vdc THMC34 or THMS34 NEC Standard 3 6-250 kcmil CU-AL
200A, 600Vac and Class J
THMC3465 400A, 600Vac THMC34 or THMS34 NEC Standard 3 6-250 kcmil CU-AL
and Class J

No-fuse ratings indicate switch capability as permitted by UL 508 (Ind. Cont. Equip.), additional hp ratings correspond to commercially available fuses.
For DC use outer poles.
1Can be used for one-step underfusing for next higher current-rated disconnect.
2Maximum UL listing 20 hp. at 600V.

9-24 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Disconnect Switches and Operating Mechanisms Section 9
Premium Duty QMW, Heavy Duty QMR
Factory Assembled Fuse Clips
Choice of Handle Style
30-600 Amperes
240, 480, 600 Vac, 250 Vdc

Product Description
These 30-600 ampere disconnect switches are complete with
Class H fuse clips except where noted, line/load lugs and handle
operators, all factory assembled, and are mounted on a heavy-
gauge steel backplate. They are UL Recognized Components, File
E-36152, and UL Recognized to Canadian safety requirements
under the Component Recognition Program of Underwriters
Laboratories Inc.
The 30-200 ampere fusible switches are UL Recognized for use on
circuits capable of delivering not more than 200,000 rms symmet-
rical amperes at 240 or 600Vac when fused with Class R rated
size fuses. Refer to the table below for the appropriate Class R
Fusing Kit. Class H Fuse Clips are standard. Suitable for NEMA 1
QMR Disconnect with TDR Handle
and NEMA 12 enclosures.

Assembled with Lugs, Fuse Clips and Handle Operators Horsepower Ratings
Disconnect Switch Max. HP Rating Max. HP Rating Max. HP Rating Max. HP Rating
Duty Type Rating (Amperes) @ 240Vac 3-Phase @ 480Vac 3-Phase @ 600Vac 3-Phase @ 250 Vdc Product Number
Heavy Duty QMR 30A 7.5 20 20 5 THMR3100
Heavy Duty QMR 30A 7.5 5 THMR3121
Heavy Duty QMR 30A 7.5 15 20 5 THMR3161
Heavy Duty QMR 60A 20 40 50 10 THMR3200
Heavy Duty QMR 60A 15 10 THMR3222
Heavy Duty QMR 60A 30 50 10 THMR3262
Heavy Duty QMR 100A 30 60 75 20 THMR3300
Heavy Duty QMR 100A 30 60 75 20 THMR33631
Heavy Duty QMR 200A 60 125 150 40 THMR3400
Heavy Duty QMR 200A 60 125 150 40 THMR34641
Heavy Duty QMR 400A 125 250 350 50 THMA35NF
Heavy Duty QMR 400A 125 50 THMA3525
Heavy Duty QMR 400A 125 250 350 THMA3565
Heavy Duty QMR 400A 125 250 350 THMA35J52
Heavy Duty QMR 400A 125 250 350 50 THMRB35NF
Heavy Duty QMR 400A 125 250 350 THMRB3565
Heavy Duty QMR 400A 125 250 350 THMRB35J52
Heavy Duty QMR 600A 200 400 500 50 THMA36NF
Heavy Duty QMR 600A 200 400 500 THMA3665
Heavy Duty QMR 600A 200 400 500 THMA36663
Heavy Duty QMR 600A 200 400 500 THMA36J62
Heavy Duty QMR 600A 200 400 500 50 THMRB36NF
Heavy Duty QMR 600A 200 400 500 THMRB36663
Heavy Duty QMR 600A 200 400 500 THMRB36J62
Heavy Duty QMR 600A 200 400 500 THMRB36L74
Premium Duty QMW 30A 7.5 5 THMCR3121
Premium Duty QMW 30A 7.5 15 20 5 THMCR3161
Premium Duty QMW 60A 20 40 50 10 THMCR3200
Premium Duty QMW 60A 15 10 THMCR3222
Premium Duty QMW 60A 30 50 10 THMCR3262
Premium Duty QMW 100A 30 60 75 20 THMCR3300
Premium Duty QMW 100A 30 60 75 20 THMCR3363
Premium Duty QMW 200A 60 125 150 40 THMCR3400
Premium Duty QMW 200A 60 125 150 40 THMCR3464

400 and 600 Ampere QMR units are UL Recognized on 100,000 Ampere rms circuits when fused with rated size Class J or R fuses.
Order Door Ring Interlock Kit343L483G4; Gasket Kit792A489G3.
400 and 600 Ampere switches with TDM handle have pendulum operation.
400 and 600 Ampere QMR units are UL Recognized on 100,000 Ampere rms circuits when fused with rated size Class J or R fuses.
1Field convertible to 250 Volt fusing.
2Supplied with Class J fuse clips.
3600 Ampere, 600 Volt Class H fused to Class J fusing. Order kit Product Number THJ6. One kit required per switch. 400 Ampere units can be field converted by moving the
fuse block toward the switch.
4Supplied with Class L fuse clips.

Rev. 11/13 www.geindustrial.com BuyLog Catalog 9-25


Data subject to change
without notice
Disconnect Switches and Operating Mechanisms Section 9
Premium Duty QMW, Heavy Duty QMR (continued)
Factory Assembled Fuse Clips
Choice of Handle Style
30-600 Amperes
240, 480, 600 Vac, 250 Vdc

Assembled Switches with Lugs, Fuse Clips and Handle Operators


Ampere Fuse Clip Rating Fuse Clip Rating
Duty Type Rating (Ampere) @ 250Vdc Max. (Ampere) @ 600Vac Max. Handle Style Lug Wire Size Product Number
Heavy Duty QMR 30A No Fuse No Fuse TDR Rotary Handle Wire Keeper, THMR3100
Term. for #14-8 Cu
Heavy Duty QMR 30A 30 TDR Rotary Handle Wire Keeper, THMR3121
Term. for #14-8 Cu
Heavy Duty QMR 30A 30 TDR Rotary Handle Wire Keeper, THMR3161
Term. for #14-8 Cu
Heavy Duty QMR 60A No Fuse No Fuse TDR Rotary Handle CU 14-2 AL 12-2 THMR3200
Heavy Duty QMR 60A 60 TDR Rotary Handle CU 14-2 AL 12-2 THMR3222
Heavy Duty QMR 60A 60 TDR Rotary Handle CU 14-2 AL 12-2 THMR3262
Heavy Duty QMR 100A No Fuse No Fuse TDR Rotary Handle 10-1/0 Cu/Al THMR3300
Heavy Duty QMR 100A 100 100 TDR Rotary Handle 10-1/0 Cu/Al THMR33631
Heavy Duty QMR 200A No Fuse No Fuse TDR Rotary Handle 6-250 kcmil Cu/Al THMR3400
Heavy Duty QMR 200A 200 200 TDR Rotary Handle 6-250 kcmil Cu/Al THMR34641
Heavy Duty QMR 400A No Fuse No Fuse TDM Adjustable (1) # 22-600 kcmil Cu/Al THMA35NF
Shaft Handle or (2) 1/0-3/0 Cu or
(2) 1/0-250 kcmil Al
Heavy Duty QMR 400A 400 TDM Adjustable (1) # 22-600 kcmil Cu/Al THMA3525
Shaft Handle or (2) 1/0-3/0 Cu or
(2) 1/0-250 kcmil Al
Heavy Duty QMR 400A 400 TDM Adjustable (1) # 22-600 kcmil Cu/A THMA3565
Shaft Handle or (2) 1/0-3/0 Cu or
(2) 1/0-250 kcmil Al
Heavy Duty QMR 400A 400 TDM Adjustable (1) # 22-600 kcmil Cu/Al THMA35J52
Shaft Handle or (2) 1/0-3/0 Cu or
(2) 1/0-250 kcmil Al
Heavy Duty QMR 400A No Fuse No Fuse TDR Rotary Handle (1) # 22-600 kcmil Cu/Al THMRB35NF
or (2) 1/0-3/0 Cu or
(2) 1/0-250 kcmil Al
Heavy Duty QMR 400A 400 TDR Rotary Handle (1) # 22-600 kcmil Cu/Al THMRB3565
or (2) 1/0-3/0 Cu or
(2) 1/0-250 kcmil Al
Heavy Duty QMR 400A 400 TDR Rotary Handle (1) # 22-600 kcmil Cu/Al THMRB35J52
or (2) 1/0-3/0 Cu or
(2) 1/0-250 kcmil Al
Heavy Duty QMR 600A No Fuse No Fuse TDM Adjustable Shaft Handle (2) # 4-600 kcmil Cu/Al THMA36NF
Heavy Duty QMR 600A 400 400 TDM Adjustable (2) # 4-600 kcmil Cu/Al THMA3665
Shaft Handle
Heavy Duty QMR 600A 600 TDM Adjustable (2) # 4-600 kcmil Cu/Al THMA36663
Shaft Handle
Heavy Duty QMR 600A 600 TDM Adjustable (2) # 4-600 kcmil Cu/Al THMA36J62
Shaft Handle
Heavy Duty QMR 600A No Fuse No Fuse TDR Rotary Handle (2) # 4-600 kcmil Cu/Al THMRB36NF
Heavy Duty QMR 600A 600 TDR Rotary Handle (2) # 4-600 kcmil Cu/Al THMRB36663
Heavy Duty QMR 600A 600 TDR Rotary Handle (2) # 4-600 kcmil Cu/Al THMRB36J62
Heavy Duty QMR 600A 800 TDR Rotary Handle (2) # 4-600 kcmil Cu/Al THMRB36L74

400 and 600 Ampere QMR units are UL Recognized on 100,000 Ampere rms circuits when fused with rated size Class J or R fuses.
Order Door Ring Interlock Kit343L483G4. Gasket Kit792A489G3.
400 and 600 Ampere switches with TDM handle have pendulum operation.
400 and 600 Ampere QMR units are UL Recognized on 100,000 Ampere rms circuits when fused with rated size Class J or R fuses.
1Field convertible to 250 Volt fusing.
2Supplied with Class J fuse clips.
3600 Ampere, 600 Volt Class H fused to Class J fusing. Order kit Product Number THJ6. One kit required per switch. 400 Ampere units can be field converted by moving the
fuse block toward the switch.
4Supplied with Class L fuse clips.

9-26 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Disconnect Switches and Operating Mechanisms Section 9
Premium Duty QMW, Heavy Duty QMR (continued)
Factory Assembled Fuse Clips
Choice of Handle Style
30-600 Amperes
240, 480, 600 Vac, 250 Vdc

Assembled Switches with Lugs, Fuse Clips and Handle Operators (Continued)
Ampere Fuse Clip Rating Fuse Clip Rating
Duty Type Rating (Ampere) @ 250Vdc Max. (Ampere) @ 600Vac Max. Handle Style Lug Wire Size Product Number
Premium Duty QMW 30A 30 TDR Rotary Handle Wire Keeper, THMCR3121
Term. for #14-8 Cu
Premium Duty QMW 30A 30 TDR Rotary Handle Wire Keeper, THMCR3161
Term. for #14-8 Cu
Premium Duty QMW 60A No Fuse No Fuse TDR Rotary Handle CU 14-2 AL 12-2 THMCR3200
Premium Duty QMW 60A 60 TDR Rotary Handle CU 14-2 AL 12-2 THMCR3222
Premium Duty QMW 60A 60 TDR Rotary Handle CU 14-2 AL 12-2 THMCR3262
Premium Duty QMW 100A No Fuse No Fuse TDR Rotary Handle 10-1/0 Cu/Al THMCR3300
Premium Duty QMW 100A 100 100 TDR Rotary Handle 10-1/0 Cu/Al THMCR3363
Premium Duty QMW 200A No Fuse No Fuse TDR Rotary Handle 6-250 kcmil Cu/Al THMCR3400
Premium Duty QMW 200A 200 200 TDR Rotary Handle 6-250 kcmil Cu/Al THMCR3464

400 and 600 Ampere QMR units are UL Recognized on 100,000 Ampere rms circuits when fused with rated size Class J or R fuses.
Order Door Ring Interlock Kit343L483G4. Gasket Kit792A489G3.
400 and 600 Ampere switches with TDM handle have pendulum operation.
400 and 600 Ampere QMR units are UL Recognized on 100,000 Ampere rms circuits when fused with rated size Class J or R fuses.
1Field convertible to 250 Volt fusing.
2Supplied with Class J fuse clips.
3600 Ampere, 600 Volt Class H fused to Class J fusing. Order kit Product Number THJ6. One kit required per switch. 400 Ampere units can be field converted by moving the
fuse block toward the switch.
4Supplied with Class L fuse clips.

Class R Fusing Conversion Kits


Switch Rating Field Installed
Amperes Volts Product Number
30 250Vdc TPBRK12A
30 600Vac TPBRK16A
60 250Vdc TPBRK22A
60 600Vac TPBRK26A
100 250Vdc/600Vac TPBRK36A
200 250Vdc/600Vac TRK46A
400 250Vdc/600Vac TPBRK56A5
600 250Vdc/600Vac TRK66A5
5Not suitable for use with individual components shown on pages 9-23 and 9-24.

Rev. 11/13 www.geindustrial.com BuyLog Catalog 9-27


Data subject to change
without notice
Disconnect Switches and Operating Mechanisms Section 9
Handle Operators

Product Description
Type STDA Flange Handles and Variable Depth Operating
Mechanisms For Use With QMR/QMW 30-200A Disconnects
Designed to meet automotive duty specifications.
NEMA 12/13 and 4/4X, UL Recognized Components, File E-
57253, and UL Recognized to Canadian safety requirements
under the Component Recognition Program of Underwriters
Laboratories Inc.
For right- or left-hand flange mountingfield convertible.
Mounting dimensions to fit standard flange enclosures
8"-24" deep.
Drilling templates and detailed installation instructions.

Flange Handle Selection


Product Number STDA1 (6-inch) and STDA2 (10-inch) flange han-
dles are interchangeable. While all operating mechanisms can be
easily operated with the 6-inch STDA1 handle, the 10-inch STDA2
may be used to obtain lower operating force and/or to provide a
proportionally larger handle on large enclosures.
Flange Handle, STDA1

Construction Details
Flange Handles Variable Depth Operating Mechanisms
Rugged aluminum alloy cast housing with provision for locking Plated steel yokes and integral mounting plates are 1/8-inch
in off position with up to three 3/16- to 5/16-inch diameter thick minimum.
padlocks. Operating yokes have toggle spring assist for positive
Optional provision for locking on by drilling hole in die casting. on/off operation.
O-ring seals for dust-tight/oil-tight duty. Mounting plates include positive yoke stops to prevent undue
Gusseted, 3/32-in. thick double-sided steel handle with large, wear on disconnect and circuit breaker toggle handles.
red-black self-extinguishing grade plastic grip. Threaded 3/8-in. dia. drive rod (16-in. lengthstandard, 22-in.
lengthoptional) provides simple variable depth connection
between flange-mounted handle and operating mechanism.
Suitable for use with Hoffman Bulletin A-25 or equivalent
enclosures.

Flange Handles
Nominal Length Installation Instruction Drilling Template Product
Enclosure Type (Inches) Number Number Number
NEMA Type 12/13 6 GEH-5314 GEH-5314 STDA1
NEMA Type 12/13 10 GEH-5314 GEH-5314 STDA2
NEMA Type 4/4X 6 GEH-5314 GEH-5314 STDA1X
NEMA Type 4/4X 10 GEH-5314 GEH-5314 STDA2X

Operating Mechanism Selection


QMR/QMW/ Operating Mechanism Product
Disconnect Description Flange Handle Product Number Installation Instruction No. Number
30-100A unfused; 30A-250V fused STDA1, 1X or STDA2, 2X GEH-5315 TDOM1A
30-100A 600V fused; 60A STDA1, 1X or STDA2, 2X GEH-5315 TDOM1B
& 100A 250V fused
200A fused or unfused STDA1, 1X or STDA2, 2X GEH-5316 TDOM2

Select individual QMR or QMW disconnect and fuse or no-fuse kit from page 9-24.

9-28 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Disconnect Switches and Operating Mechanisms Section 9
Accessories and Modifications
For Type STDA Flange Handles and Operating Mechanisms

Auxiliary Contact Kit Door Hardware, NEMA 12/12 and 4/4X


Available SPDT and DPDT and actuated by operating Type TDV door hardware provides sealing and interlocking of
mechanism yoke. 3/4-inch nominal door depth hinged on left or right. Interlocking
When TDA When TDA design requires use of screwdriver to release. When used with
Used With Operating handle is on handle is on Product
Contacts Mechanism Product Number Right Flange Left Flange Number STDA flange handle and operating mechanisms, disconnect or cir-
SPDT TDOM1A, TDOM1B, TDOM2 TDAS1L1 cuit breaker cannot be turned on unless door and door hardware
SPDT TDOM1A, TDOM1B, TDOM2 TDAS1R1 have been closed. For noninterlocking type, one bracket in kit is
DPDT TDOM1A, TDOM1B, TDOM2 TDAS1L2
DPDT TDOM1A, TDOM1B, TDOM2 TDAS1R2
not used. Use of third-point latch recommended for doors 40
inches or longer.
Accessory Type Description Product Number
Auxiliary Contact Electrical Ratings
Door Hardware- NEMA 12/13 TDV1
Type AC Voltage DC Voltage Double Throw Left Hinged two-point
1-Pole 120 240 480 600 120 240 600 interlocking
Make 40 20 20 8 0.5 0.2 .02 door hardware kit
Break 15 10 6 5 0.5 0.2 .02 Door Hardware- NEMA 4/4X TDV1X
2-Pole 30 15 8 6 0.2 0.1 Left Hinged two-point
Make 3 1.5 1 0.8 0.2 0.1 interlocking
Break door hardware kit
Door Hardware- Third-point TDV3
Left Hinged latch kit for above
Door Hardware- NEMA 12/13 TDV1L
Flange Stiffener Kit, Extended Drive Rod Right Hinged two-point
Provides rigid 3/8-inch diameter rod between STDA handle interlocking
door hardware kit
mounting surface (flange or center mullion) and operating Door Hardware- Third-point TDV3L
mechanism when STDA handle would otherwise not be rigidly Right Hinged latch kit for above
supported.
Rod length is 22 inches and may be cut to appropriate length.
Also used as extended length drive rod when standard 16-inch Agency Certifications
rod is not long enough. STDA accessories are UL Recognized Components, File E-36152,
Used With Operating and UL Recognized to Canadian safety requirements under the
Mechanism Product Number Product Number
Component Recognition Program of Underwriters Laboratories Inc.
TDOM1A, 1B, TDOM2 TDSR

Reference Publications
Extended Drive Stud
Door Hardware GEH-5322
This optional drive stud permits locating the operating mechanism Auxiliary Contact Kit GEH-5323
Flange Stiffener Kit or Extended-Length Drive Rod GEH-5324
1 5/16 inches further to the left (when flange handle is on right Extended Drive Stud GEH-5325
side) or to the right (when handle is on left side) to accommodate Operating Mechanism:
specific mounting restrictions. TDOM1A through TDOM1B GEH-5315
TDOM2 GEH-5316
Used With Operating
Mechanism Product Number Product Number
TDOM1A, TDOM1B, TDOM2 TDS1

Rev. 11/13 www.geindustrial.com BuyLog Catalog 9-29


Data subject to change
without notice
Disconnect Switches and Operating Mechanisms Section 9
Accessories and Modifications

Overpack Kits
QMW disconnect switch, fuse kit with copper lugs, operating mechanism and STDA1 flange handle packed in a single carton.

QMW with Copper Lugs for Copper Cables Only and Class R Rejection Clips for Class R Fusing
Ampere Fuse Clip System Fuse Kit Prod. No. Variable Depth Operating Product
Rating Rating (Ampere) Voltage (or No-Fuse Kit Prod. No.) Mechanism Prod. No. Number
30A No Fuse No Fuse THMC3200CL TDOM1A STDAD3NF
30A 30 250Vdc THMC3121CLR TDOM1A STDAD332R
30A 30 600Vac THMC3161CLR TDOM1B STDAD336R
60A No Fuse No Fuse THMC3200CL TDOM1A STDAD6NF
60A 60 250Vdc THMC3222CLR TDOM1B STDAD662R
60A 60 600Vac THMC3262CLR TDOM1B STDAD666R
100A No Fuse No Fuse THMC3300CL TDOM1A STDAD1NF
250Vdc
100A 100 600Vac THMC3363CLR TDOM1B STDAD100R
200A No Fuse No Fuse THMC3400CL TDOM2 STDAD2NF
250Vdc
200A 200 600Vac THMC3464CLR TDOM2 STDAD200R

QMW with Copper Lugs for Copper Cables Only and Class J Clips for Class J Fusing
Ampere Fuse Clip System Fuse Kit Prod. No. Variable Depth Operating Product
Rating Rating (Ampere) Voltage (or No-Fuse Kit Prod. No.) Mechanism Prod. No. Number
30A 30 600Vac THMC3161CL TDOM1JA STDAD336J
30A 60 600Vac THMC3262CL TDOM1JB STDAD3362J
60A 60 600Vac THMC3262CL TDOM1JB STDAD666J
60A 100 600Vac THMC3363CL TDOM1JA STDAD6663J
100A 100 600Vac THMC3363CL TDOM1JA STDAD106J
100A 200 600Vac THMC3364CL TDOM1A STDAD1064J
200A 200 600Vac THMC3464CL TDOM2 STDAD206J
200A 400 600Vac THMC3465 TDOM2 STDAD2065J

9-30 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Disconnect Switches and Operating Mechanisms Section 9
General-Duty HCl
Individual Components
30-200 Amperes
240, 480, 600 Vac, 250 Vdc

Fuse Clip and No Fuse Kits Horsepower Ratings


For Basic Switches with 600 Volt Industrial Control and 250 Volt Enclosed Switch and Switchboard Clearance Spacings
HP Rating, AC, HP Rating, AC, HP Rating, AC, HP Rating, AC, HP Rating, AC, HP Rating, AC,
Basic Switch 3-Phase, NEC 3-Phase, NEC 3-Phase,NEC 3-Phase, Time-Delay 3-Phase, Time-Delay 3-Phase, Time-Delay HP Rating, Product
Rating Standard @ 240Vac Standard @ 480Vac Standard @ 600Vac Fuse @ 240Vac Fuse @ 480Vac Fuse @ 600Vac 250Vdc Number
30 Ampere 3-Pole 7.5 15 20 5 THC31001,3
30 Ampere 3-Pole 3 7.5 5 THC3121
30 Ampere 3-Pole 5 7.5 15 20 THC3161
30 Ampere 3-Pole 5 7.5 15 20 THC31J1
30 Ampere 3-Pole 7.5 THC3122
30 Ampere 3-Pole 15 15 THC3162
30 Ampere 3-Pole 15 15 THC31J2
60 Ampere 3-Pole 15 30 50 10 THC32002
60 Ampere 3-Pole 3 10 THC32212
60 Ampere 3-Pole 5 7.5 THC32612
60 Ampere 3-Pole 7.5 15 THC32222
60 Ampere 3-Pole 15 15 30 50 THC32622
60 Ampere 3-Pole 15 15 30 50 THC32J22
60 Ampere 3-Pole 15 THC32232
60 Ampere 3-Pole 25 30 THC32632
60 Ampere 3-Pole 25 30 THC32J32
100 Ampere 3-Pole 30 60 75 20 THC3300
100 Ampere 3-Pole 7.5 20 THC3322
100 Ampere 3-Pole 15 15 THC3362
100 Ampere 3-Pole 15 30 THC3323
100 Ampere 3-Pole 25 30 60 75 THC3363
100 Ampere 3-Pole 25 30 60 75 THC33J3
100 Ampere 3-Pole 25 THC3324
100 Ampere 3-Pole 50 60 THC3364
100 Ampere 3-Pole 50 60 THC33J4
200 Ampere 3-Pole 60 100 100 40 THC3400
200 Ampere 3-Pole 15 40 THC3423
200 Ampere 3-Pole 25 30 THC3463
200 Ampere 3-Pole 25 30 THC34J3
200 Ampere 3-Pole 25 60 THC3424
200 Ampere 3-Pole 50 60 100 100 THC3464
200 Ampere 3-Pole 50 60 100 100 THC34J4
200 Ampere 3-Pole 50 THC3425
200 Ampere 3-Pole 100 100 THC3465
200 Ampere 3-Pole 100 100 THC34J5

Fuse and No-Fuse Kits Horsepower Ratings


For Basic Switches with 600 Volt Enclosed Switch and Switchboard Clearance Spacings
HP Rating, AC, HP Rating, AC, HP Rating, AC, HP Rating, AC, HP Rating, AC, HP Rating, AC,
Basic Switch 3-Phase, NEC 3-Phase, NEC 3-Phase, NEC 3-Phase, Time-Delay 3-Phase, Time-Delay 3-Phase, Time-Delay HP Rating, Product
Rating Standard @ 240Vac Standard @ 480Vac Standard @ 600Vac Fuse @ 240Vac Fuse @ 480Vac Fuse @ 600Vac 250Vdc Number
30 Ampere 3-Pole 3 5 7.5 15 20 5 THC31S611,3
30 Ampere 3-Pole 3 5 7.5 15 20 5 THC31SJ11,3
30 Ampere 3-Pole 7.5 15 20 5 THC31001,3
60 Ampere 3-Pole 7.5 15 15 30 50 10 THC32S62
60 Ampere 3-Pole 7.5 15 15 30 50 10 THC32SJ2
60 Ampere 3-Pole 15 30 50 10 THC32002
100 Ampere 3-Pole 25 30 60 75 THC3363
100 Ampere 3-Pole 25 30 60 75 THC33J3
100 Ampere 3-Pole 30 60 75 20 THC3300
200 Ampere 3-Pole 50 60 100 100 THC3464
200 Ampere 3-Pole 50 60 100 100 THC34J4
200 Ampere 3-Pole 60 100 100 40 THC3400

Auxiliary switch (SPDT) for HCI rated .5 ampere at 125Vdc, .25 ampere at 250Vdc, 15 ampere at 480Vac. Product Number 343L296G2.
HCI switches, fuse and no-fuse kits, are listed in UL Recognized Component Index (WHTY2) for mounting in a vertical position, line side up. UL File E-36152.
Line shield included with THC31 and THC31S. All other line shields included with fuse-clip or no-fuse kits.
For Two-pole applicationsUse two poles of three-pole switch.
HCI switches, fuse and no-fuse kits, are listed in UL Recognized Component Index (WHTY2) for mounting in a vertical position, line side up. UL File E-36152.
Inside enclosure depth may be reduced to these depths while maintaining electrical spacingsrequires cutting handle shaft.
1Suitable for 25 hp @ 600 V but not UL listed.
2Basic switch with UL 600 Volt industrial control spacings only.
3For 30 ampere switch with 600 Volt enclosed switch spacing and 60 ampere terminals, order Product Number THC31SSE.

Rev. 11/13 www.geindustrial.com BuyLog Catalog 9-31


Data subject to change
without notice
Disconnect Switches and Operating Mechanisms Section 9
General-Duty HCl (continued)
Individual Components
30-200 Amperes
240, 480, 600 Vac, 250 Vdc

Fuse Clip and No Fuse Kits


For Basic Switches with 600 Volt Industrial Control and 250 Volt Enclosed Switch and Switchboard Clearance Spacings.

Basic Switch Rating Basic Switch Product Number Fuse Type Fuse Kit Rating Product Number
30 Ampere 3-Pole THC31S No Fuse No Fuse600 THC31001,3
30 Ampere 3-Pole THC31 NEC Standard 30A, 240Vac/250Vdc THC3121
30 Ampere 3-Pole THC31 NEC Standard 30A, 600Vac THC3161
30 Ampere 3-Pole THC31 Class J 30A, 600Vac THC31J1
30 Ampere 3-Pole THC31 NEC Standard 60A, 240Vac/250Vdc THC3122
30 Ampere 3-Pole THC31 NEC Standard 60A, 600Vac THC3162
30 Ampere 3-Pole THC31 Class J 60A, 600Vac THC31J2
60 Ampere 3-Pole THC32S No Fuse No Fuse600 THC32002
60 Ampere 3-Pole THC32 NEC Standard 30A, 240Vac/250Vdc THC32212
60 Ampere 3-Pole THC32 NEC Standard 30A, 600Vac THC32612
60 Ampere 3-Pole THC32 NEC Standard 60A, 240Vac/250Vdc THC32222
60 Ampere 3-Pole THC32 NEC Standard 60A, 600Vac THC32622
60 Ampere 3-Pole THC32 Class J 60A, 600Vac THC32J22
60 Ampere 3-Pole THC32 NEC Standard 100A, 240Vac/250Vdc THC32232
60 Ampere 3-Pole THC32 NEC Standard 100A, 600Vac THC32632
60 Ampere 3-Pole THC32 Class J 100A, 600Vac THC32J32
100 Ampere 3-Pole THC33S No Fuse No Fuse600 THC3300
100 Ampere 3-Pole THC33 NEC Standard 60A, 240Vac/250Vdc THC3322
100 Ampere 3-Pole THC33 NEC Standard 60A, 600Vac THC3362
100 Ampere 3-Pole THC33 NEC Standard 100A, 240Vac/250Vdc THC3323
100 Ampere 3-Pole THC33S NEC Standard 100A, 600Vac THC3363
100 Ampere 3-Pole THC33S Class J 100A, 600Vac THC33J3
100 Ampere 3-Pole THC33 NEC Standard 200A, 240Vac/250Vdc THC3324
100 Ampere 3-Pole THC33 NEC Standard 200A, 600Vac THC3364
100 Ampere 3-Pole THC33 Class J 200A, 600Vac THC33J4
200 Ampere 3-Pole THC34S No Fuse No Fuse600 THC3400
200 Ampere 3-Pole THC34 NEC Standard 100A, 240Vac/250Vdc THC3423
200 Ampere 3-Pole THC34 NEC Standard 100A, 600Vac THC3463
200 Ampere 3-Pole THC34 Class J 100A, 600Vac THC34J3
200 Ampere 3-Pole THC34 NEC Standard 200A, 240Vac/250Vdc THC3424
200 Ampere 3-Pole THC34 NEC Standard 200A, 600Vac THC3464
200 Ampere 3-Pole THC34 Class J 200A, 600Vac THC34J4
200 Ampere 3-Pole THC34 NEC Standard 400A, 240Vac/250Vdc THC3425
200 Ampere 3-Pole THC34 NEC Standard 400A, 600Vac THC3465
200 Ampere 3-Pole THC34 Class J 400A, 600Vac THC34J5

Fuse Clip and No Fuse Kits


For Basic Switches with 600 Volt Enclosed Switch and Switchboard Clearance Spacings.

Basic Switch Rating Basic Switch Product Number Fuse Type Fuse Kit Rating Product Number
30 Ampere 3-Pole THC31S NEC Standard 30A, 600Vac THC31S611,3
30 Ampere 3-Pole THC31S Class J 30A, 600Vac THC31SJ11,3
30 Ampere 3-Pole THC31S No Fuse No Fuse600 THC31001,3
60 Ampere 3-Pole THC32S NEC Standard 60A, 600Vac THC32S62
60 Ampere 3-Pole THC32S Class J 60A, 600Vac THC32SJ2
60 Ampere 3-Pole THC32S No Fuse No Fuse600 THC32002
100 Ampere 3-Pole THC33S NEC Standard 100A, 600Vac THC3363
100 Ampere 3-Pole THC33S Class J 100A, 600Vac THC33J3
100 Ampere 3-Pole THC33S No Fuse No Fuse600 THC3300
200 Ampere 3-Pole THC34 NEC Standard 200A, 600Vac THC3464
200 Ampere 3-Pole THC34 Class J 200A, 600Vac THC34J4
200 Ampere 3-Pole THC34S No Fuse No Fuse600 THC3400

Auxiliary switch (SPDT) for HCI rated .5 ampere at 125Vdc, .25 ampere at 250Vdc, 15 ampere at 480Vac. Product Number 343L296G2.
HCI switches, fuse and no-fuse kits, are listed in UL Recognized Component Index (WHTY2) for mounting in a vertical position, line side up. UL File E-36152.
Line shield included with THC31 and THC31S. All other line shields included with fuse-clip or no-fuse kits.
For Two-pole applicationsUse two poles of three-pole switch.
HCI switches, fuse and no-fuse kits, are listed in UL Recognized Component Index (WHTY2) for mounting in a vertical position, line side up. UL File E-36152.
Inside enclosure depth may be reduced to these depths while maintaining electrical spacingsrequires cutting handle shaft.

1Suitable for 25 hp @ 600 V but not UL listed.


2Basic switch with UL 600 Volt industrial control spacings only.
3For 30 ampere switch with 600 Volt enclosed switch spacing and 60 ampere terminals, order Product Number THC31SSE.

9-32 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Disconnect Switches and Operating Mechanisms Section 9
TDR Handle Mechanism
Handle Operating Mechanisms

TDR Integral Handle Mechanism for QMR/QMW Disconnects


Rotary operating handle mounts directly to disconnect.
Operates through enclosure doormechanical interlock
designed to prevent unauthorized opening of enclosure when
disconnect is ON.
Locking hasp accommodates up to three padlocks.
Suitable for use with NEMA 1, 12, and 12K enclosures.
UL Recognized Components, File E-36152.

TDR Handle

Integral Handles (Separate Kits for Field Assembly)


Add to Switch Product No. Suffix
Accessory Type Ampere Rating for Factory Assembly Product Number
Integral Handle, Vertical 30A, 60A, 100A V1 THMR1B
Integral Handle, Vertical 200A V2 THMR2B
Integral Handle, Horizontal 30A, 60A, 100A H1 THMR1HB
Integral Handle, Horizontal 200A H1 THMR2HB
Door ring interlock SEFRDRCK
Gasket kit SEFRGSK

Auxiliary Switches (Separate Kits for Field Assembly)


Add to Integral Handle Product No.
Accessory Type Ampere Rating Suffix for Factory Installation Product Number
Auxiliary Switch 100 AS1 343L492G1
Auxiliary Switch 200 AS2 343L492G2

Rev. 11/13 www.geindustrial.com BuyLog Catalog 9-33


Data subject to change
without notice
Disconnect Switches and Operating Mechanisms Section 9
FD1 Fusible IEC Style
Individual Components
600 Vac
250 Vdc

Horsepower Ratings (Time Delay)


FD130CC
Fuse Operating Characteristics
Maximum HP, Maximum HP, Maximum HP, Maximum HP, Maximum HP,
3-Phase 3-Phase 3-Phase Single-Phase Single-Phase Maximum Maximum
AC @ 240Vac, AC @ 480Vac, AC @ 600Vac, AC @ 120Vac, AC @ 240Vac, HP, HP,
Product 60Hz, 60Hz, 60Hz, 60Hz, 60Hz, DC @ 125Vdc, DC @ 250Vdc,
Number Time Delay Time Delay Time Delay Time Delay Time Delay Time Delay Time Delay
FD130CC 5 10 10 0.75 2 2 3
FD130J 7.5 15 20 2 3 3 5
FD130NF 7.5 15 20 2 3 3 5
FD160J 15 30 50 3 10 5 10
FD160NF 15 30 50 3 10 5 10
FD1100J 30 60 75 15 20 FD130J
FD1100NF 30 60 75 15 20
FD1200J 60 125 150 25 40
FD1200NF 60 125 150 25 40

Horsepower Ratings (Non-Time Delay)


Fuse Operating Characteristics
Maximum HP, Maximum HP, Maximum HP, Maximum HP, Maximum HP,
3-Phase 3-Phase 3-Phase Single-Phase Single-Phase
AC @ 240Vac, AC @ 480Vac, AC @ 600Vac, AC @ 120Vac, AC @ 240Vac, Maximum HP, Maximum HP,
Product 60Hz, 60Hz, 60Hz, 60Hz, 60Hz, DC @ 125Vdc, DC @ 250Vdc, FD130NF
Number Non-Time Delay Non-Time Delay Non-Time Delay Non-Time Delay Non-Time Delay Non-Time Delay Non-Time Delay
FD130CC 5 10 10 0.75 2 2 3
FD130J 3 5 7.5 0.5 1.5 2 5
FD130NF 3 5 7.5 0.5 1.5 2 5
FD160J 7.5 15 15 1.5 3 5 5
FD160NF 7.5 15 15 1.5 3 5 5
FD1100J 15 25 30 7.5 20
FD1100NF 15 25 30 7.5 20
FD1200J 25 50 60 15 40
FD1200NF 25 50 60 15 40

FD160J

IEC Disconnects Fuse Specification


Ampere Fuse Maximum Fuse Maximum Maximum Available Product
Rating Type Cartridge Size Voltage Fault Current Number
30A Class CC HRCI-MISC 30 A 600Vac/250Vac 100 kA FD130CC2
30A Class J HRCI-J 30 A 600Vac/250Vac 100 kA FD130J
30A Non-Fused 30 A 600Vac/250Vac 100 kA FD130NF1,2
60A Class J HRCI-J 60 A 600Vac/250Vac 100 kA FD160J
60A Non-Fused 60 A 600Vac/250Vac 100 kA FD160NF1,2
100A Class J HRCI-J 100 600Vac/250Vac 100 kA FD1100J
100A Non-Fused Non-Fused 600Vac/250Vac 100 kA FD1100NF1,2 FD160NF
200A Class J HRCI-J 200 600Vac/250Vac 100 kA FD1200J
200A Non-Fused Non-Fused 600Vac/250Vac 100 kA FD1200NF1,2
1Non-fused disconnect switches must be used with separately installed UL Listed class J, CC or T fuses; or CSA
Certified HRCI-J, HRCI-T or HRCI-MISC.
2CSA HRCI-MISC fuses must also be UL Listed as class CC fuses.

Mechanical Specifications3
Product Mechanical Endurance Normal Operating Terminal Capacity / Terminal Capacity / Maximum Number of
Number Operations Torque Power Terminals Auxiliary Switch Terminals Auxiliary Circuits FD1100J and FD1200J
FD130CC 10000 27 #14 - #8 #14 - #12 4
FD130J 10000 27 #14 - #8 #14 - #12 4
FD130NF 10000 27 #14 - #8 #14 - #12 4
FD160J 10000 45 #14 - #4 #14 - #12 4
FD160NF1 10000 45 #14 - #4 #14 - #12 4
FD1100J 10000 107 #14 - #2 #14 - #12 4
FD1100NF 10000 107 #14 - #2 #14 - #12 4
FD1200J 10000 239 #6 - 250kcmil #14 - #12 4
FD1200NF 10000 239 #6 - 250kcmil #14 - #12 4
3See page 9-38 for additional Mechanical Specifications.
FD1100NF and FD1200NF

9-34 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Disconnect Switches and Operating Mechanisms Section 9
FD1 Fusible IEC Style
Accessories

Door Mounted Rotary Operating Handles NEMA Type 1/12/4/4X (IP65)

Switch Type Color Comments Product Number


FD130 or FD160 Black NEMA 4, 4X, FD1HA4XB
with defeat to enable
panel entry while power on.
FD130 or FD160 Red/Yellow NEMA 4, 4X, FD1HA4XRY
with defeat to enable
panel entry while power on.
FD1100 or FD1200 Black NEMA 3R, FD11HA1B
simple on/off
pistol grip handle
FD1100 or FD1200 Red/Yellow NEMA 3R, FD11HA1RY
simple on/off
pistol grip handle
Pistol Grip Operating Handle
FD1100 or FD1200 Black NEMA 3R, FD11HA4B
on/off with lock-out
tag-out pistol grip handle
FD1100 or FD1200 Red/Yellow NEMA 3R, FD11HA4RY
on/off with lock-out
tag-out pistol grip handle
FD1100 or FD1200 Black NEMA 3R, FD11HA3B
on/off with lock-out
tag-out and defeatable
pistol grip handle
FD1100 or FD1200 Red/Yellow NEMA 3R, FD11HA3RY
on/off with lock-out
tag-out and defeatable
pistol grip handle

Operating Shafts Rotary Operating Handle

Switch Type Handle Type Enclosure Depth (Max.) Shaft Length Product Number
FD130 or FD1HA4X 10 15/64 (260) 166mm or FD1S166
FD160 6 17/32in.
FD130 or FD1HA4X 17 7/8 (454) 360mm or FD1S360
FD160 14 11/64in.
FD1100 or FD11HA 11 21/38 (296) 200mm or FD1S12
FD1200 7 7/8in.
FD1100 or FD11HA 16 15/64 (430) 319mm or FD1L12
FD1200 12 19/32in.

Auxiliary Switches

Switch Type Description Contact Configuration Location Product Number


FD130, FD160, FD1100 SPDT NO First FD1ASNO1 Operating Shafts
or FD1200
FD130, FD160, FD1100 SPDT NC First FD1ASNC1
or FD1200
FD130, FD160, FD1100 SPDT NO Second FD1ASNO2
or FD1200
FD130, FD160, FD1100 DPDT 2 NO First FD1ASNO11
or FD1200
FD130, FD160, FD1100 DPDT 2 NC First FD1ASNC11
or FD1200
FD130, FD160, FD1100 DPDT 2 NO Second FD1ASNO22
or FD1200

Auxiliary Switch with Terminal Shields

Rev. 11/13 www.geindustrial.com BuyLog Catalog 9-35


Data subject to change
without notice
Disconnect Switches and Operating Mechanisms Section 9
FD1 Fusible IEC Style (continued)
Accessories

Other Accessories
Accessory Type Switch Type Comments Product Number
Terminal Shields FD130 Terminal shield for FD130TS
line or load side.
One shield supplied
with switch as standard.
Terminal Shields FD160 Terminal shield for FD160TS
line or load side.
One shield supplied
with switch as standard.
Terminal Shields FD1100 Terminal shield for FD1100TS
line or load side.
One shield supplied
with switch as standard.
Terminal Shields
Terminal Shields FD1200 Terminal shield for FD1200TS
line or load side.
One shield supplied
with switch as standard.
Shorting Links FD130 Package of 3. Use as FD130LNK
replacements in FD130NF
and FD160NF.
Shorting Links FD160 Package of 3. Use as FD160LNK
replacements in FD130NF
and FD160NF.
Shorting Links FD1100 For non-fused applications. FD1100LNK
Shorting Links FD1200 For non-fused applications. FD1200LNK
Fuse Covers FD130CC FD130CV1
FD130NF
Fuse Covers FD130J FD130JCV1
Fuse Covers FD160J FD160JCV1
FD160NF
Fuse Covers FD1100 FD1100JCV1
Fuse Covers FD1200 FD1200JCV1 Shorting Links
Auxiliary Switch All Package of 2. FD1ASCV1
Terminal Shields

Lug Kits

Type Description Product Number


100A 3 mech conn. FD1LK1
200A 3 mech conn. FD1LK2

Fuse Covers

Lugs Kits

9-36 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Disconnect Switches and Operating Mechanisms Section 9
FD1 Fusible IEC Style
Outlines and Dimensions

Type FD1 Dimension References - in. (mm) [2] F x .70 or


Product Number Dimension A Dimension B Dimension C Dimension D Dimension E Dimension F [2]# 6

FD130CC 4 19/64 (109) 3 23/64 (85) 4 21/64 (110) 3 15/64 (82) 4 13/32 (112) M4
FD130J 4 19/64 (109) 3 11/32 (85) 4 21/64 (110) 3 15/64 (82) 5 15/64 (133) M4
FD130NF 4 19/64 (109) 3 23/64 (85) 4 21/64 (110) 3 15/64 (82) 4 13/32 (112) M4
FD160J 4 41/64 (118) 4 23/32 (120) 5 19/32 (142) 3 15/16 (100) 4 49/64 (121) M4
D A
FD160NF 4 41/64 (118) 4 23/32 (120) 5 19/32 (142) 3 15/16 (100) 4 49/64 (121) M4
FD1100J 6 21/32 (169) 6 7/32 (158) 7 11/64 (182) 4 9/64 (105) 4 59/64 (125) M6
FD1100NF 6 21/32 (169) 6 7/32 (158) 7 11/64 (182) 4 9/64 (105) 4 59/64 (125) M6
FD1200J 9 27/32 (250) 8 21/32 (220) 9 17/32 (242) 5 29/32 (150) 7 (178) M8
FD1200NF 9 27/32 (250) 8 21/32 (220) 9 17/32 (242) 5 29/32 (150) 7 (178) M8 B E
C

Type FD1 Additional Mechanical Specifications Type FD1


Product Approx. Net Minimum Enclosure Minimum Enclosure Minimum Enclosure
Number Weight (Lbs.) Size - Height (in.) Size - Width Size - Depth
FD130CC 2.03 9.875 6.875 6.375
FD130J 2.03 9.875 6.875 6.375
FD130NF 1.78 9.875 6.875 6.375
FD160J 2.90 9.875 7.875 6.375
FD160NF 2.52 9.875 7.875 6.375
FD1100J 6.87 15.75 11.50 7.75
FD1100NF 6.82 15.75 11.50 7.75
FD1200J 15.84 15.75 11.50 7.75
FD1200NF 16.39 15.75 11.50 7.75

Approvals/Standards
UL Listed (UL 489)
CSA Certified (CSA 22.2 No. 4)
Meets service entrance requirements
CE Marked

Rev. 11/13 www.geindustrial.com BuyLog Catalog 9-37


Data subject to change
without notice
Disconnect Switches and Operating Mechanisms Section 9
DILOS Nonfusible Vu-Break IEC Style
Individual Components
480 Vac

IEC Disconnects Non Fused


Ampere No. of Horsepower Horsepower
Rating Poles 460 Vac 230 Vac Product Number
30A 3 10 5 D/061312-201
60A 3 15 7.5 D/061314-201
80A 3 20 10 D/061315-201
100A 3 25 15 D/061324-201
125A 3 30 15 D/061326-201

Ratings Per IEC 947-3


Product Rated Current Rated Current Rated Current Terminal Rated operational
Number at 40 C at 50 C at 60 C Capacity (CU) voltage Ue
D/061312-201 40 A 40 A 40 A 6 mm2 Min. 690 V
50 mm2 Max. DILOS 1
D/061314-201 63 A 63 A 63 A 6 mm2 Min. 690 V
50 mm2 Max.
D/061315-201 80 A 80 A 80 A 6 mm2 Min. 690 V
50 mm2 Max.
D/061324-201 160 A 160 A 160 A Copper bus 690 V
maximum 6 x 20mm
D/061326-201 200 A 200 A 200 A Copper bus 690 V
maximum 6 x 20mm

Ratings Per IEC 947-3 (Continued)


Rated Operation Rated Operation Rated Operation
Impulse Test Current Ie @ Current Ie @ Current Ie @
Product Rated Insulation Rated Impulse Voltage at Utilization AC21A Utilization AC22a Utilization AC23A
Number Voltage Ui Voltage Uimp Sea Level at Ue=415V at Ue=415V at Ue=415V
D/061312-201 690 V 8 kV 12.3 kV 40 A 40 A 40 A
D/061314-201 690 V 8 kV 12.3 kV 63 A 63 A 50 A
DILOS 2
D/061315-201 690 V 8 kV 12.3 kV 80 A 80 A 80 A
D/061324-201 690 V 8 kV 12.3 kV 160 A 160 A 125 A
D/061326-201 690 V 8 kV 12.3 kV 200 A 200 A 160 A

Ratings Per IEC 947-3 (Continued)


Rated Short-time Rated Short-time Rated Short-circuit Rated Short-circuit
Product Withstand Current Withstand Current Peak Short-Circuit Making Capacity Making Capacity
Product Icw, 1 sec. Icw, 0.25 sec. Withstand Current Icm, Ue=400V Icm, Ue=415V
D/061312-201 3 kA rms 6 kA rms 10 kA rms 10 kA 10 kA
D/061314-201 3 kA rms 6 kA rms 10 kA rms 10 kA 10 kA
D/061315-201 3 kA rms 6 kA rms 10 kA rms 10 kA 10 kA
D/061324-201 3 kA rms 6 kA rms 10 kA rms 10 kA 10 kA
D/061326-201 3 kA rms 6 kA rms 10 kA rms 10 kA 10 kA

Ratings Per IEC 947-3 (Continued)


Rated Conditional Rated Conditional Rated Rated Operational
Short-Circuit Short-Circuit Operational Current DC23A
Product Withstand Withstand Current DC23A (2P Series) Electrical Mechanical
Number Current @ 400V Current @ 415V (2P Series) @ 110V @ 220V Durability Durability
D/061312-201 50 kA rms 50 kA rms 40 A 40 A 1500 Cycles 20000 Cycles
D/061314-201 50 kA rms 50 kA rms 63 A 63 A 1500 Cycles 20000 Cycles
D/061315-201 50 kA rms 50 kA rms 80 A 1500 Cycles 20000 Cycles
D/061324-201 50 kA rms 50 kA rms 160 A 100 A 1000 Cycles 10000 Cycles
D/061326-201 50 kA rms 50 kA rms 160 A 100 A 1000 Cycles 10000 Cycles

9-38 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Disconnect Switches and Operating Mechanisms Section 9
DILOS Nonfusible Vu-Break IEC Style
Accessories

Auxiliary Switches

No. of Poles Comments Product Number


1 Adds 9mm to width of switch. D/061901-001
2 Adds 9mm to width of switch. D/061901-002

Auxiliary Switches

Padlocking Device
Comments Product Number
For padlock with maximum D/061900-020
8mm or 5/16" diameter.

Padlocking Device

Inbus Key

Shaft Length Comments Product Number


200mm S5 Insulated D/061000-097

Inbus Key

Operating Handle with Extension Shaft NEMA 1/12

Shaft Length Handle Color Product Number


200mm Black D/061910-002
200mm Red/Yellow D/061910-012
400mm Black D/061910-004
400mm Red/Yellow D/061910-014

Operating Handle with Extension Shaft

Lugs

Wire Size Comments Product Number


#8-250 kcmil CU Package of 3 D/061922-003

Lugs

Rev. 11/13 www.geindustrial.com BuyLog Catalog 9-39


Data subject to change
without notice
Disconnect Switches and Operating Mechanisms Section 9
DILOS Nonfusible Vu-Break IEC Style
Outlines and Dimensions

DILOS Weights
Product Number Weight (Lbs.) Weight (kg)
D/061312-201 1.2 0.54 kg
D/061314-201 1.2 0.54 kg
D/061315-201 1.2 0.54 kg
D/061324-201 1.6 0.73 kg
D/061326-201 1.6 0.73 kg

Approvals/Standards
UL Listed (UL 489)
IEC 947-1, 947-3
EN 60947-3

DILOS 1

DILOS 2

9-40 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Section Updated 09 / 2016

Dry Type Transformers Section 10


For more information on these products, order publications listed Find What You Need Faster - Page headings and table
in Section 28. formatmake product selection easier.
Easy Cross Reference -Frame sizelisted with each model
number. Useframe size tocross-reference dimensions,
enclosure parts, andaccessories.

General Information
Types QB, QMS, QL ..................................................................................10-2 Servicenter Mini-Unit Substations
General Purpose Integral Transformer and Distribution Center...................10-32
Single-Phase DOE 2016 Efficiency, Aluminum...........................10-4 Single-Phase and Three-Phase DOE 2016 Efficiency ..........10-33
Single-Phase DOE 2016 Efficiency, Copper.................................10-5 Outlines, Dimensions, Wiring Diagrams.....................................10-34
Three-Phase DOE 2016 Product Number Nomenclature.....10-6 Totally Enclosed, Nonventilated TENV ..............................10-35
Three-Phase DOE 2016 Efficiency, Aluminum ...........................10-9 Aluminum and Copper DOE 2016 Efficiency ...........................10-36
Three-Phase DOE 2016 Efficiency, Copper...............................10-11 Midtapped
K-Factor Aluminum DOE 2016 Efficiency......................................................10-37
Three-Phase DOE 2016 Efficiency, Aluminum.........................10-12 Copper DOE 2016 Efficiency............................................................10-38
Three-Phase DOE 2016 Efficiency, Copper...............................10-16 Drive Isolation
K-Factor Low Noise Three-Phase.............................................................................................10-40
Three-Phase DOE 2016 Efficiency, Aluminum.........................10-20 Accessories and Lugs ..............................................................10-42
Three-Phase DOE 2016 Efficiency, Copper...............................10-22 Enclosure Parts.........................................................................10-44
Low Noise Wiring Diagrams ......................................................................10-45
Three-Phase DOE 2016 Efficiency, Aluminum.........................10-24 Dimensions ................................................................................10-46
Three-Phase DOE 2016 Efficiency, Copper...............................10-25 General Purpose Transformers in Enclosures
Noise Isolation Guard I Single-Phase............................................................................................10-48
Three-Phase DOE 2016 Efficiency, Aluminum.........................10-26 Buck-Boost Encapsulated Transformers .............................10-51
Three-Phase DOE 2016 Efficiency, Copper...............................10-27 Selection Tables .....................................................................................10-54
Noise Isolation Guard II .......................................................10-28 Connection Diagrams .........................................................................10-61
Three-Phase DOE 2016 Efficiency, Aluminum.........................10-29 Open Core and Coil Transformers ........................................10-62
Three-Phase DOE 2016 Efficiency, Copper...............................10-30 Machine Tool Applications................................................................10-63
Harmonic Mitigating Guard III Control........................................................................................................10-64
Three-Phase DOE 2016 Efficiency, Copper...............................10-31 Options and Fusing Guide ................................................................10-66
Wiring Diagrams ...................................................................................10-67
Outlines and Dimensions ..................................................................10-68
CE-Rated....................................................................................................10-69

Rev. 11/13 www.geindustrial.com BuyLogTM Catalog 10-1


Data subject to change
without notice
Dry Type Transformers Section 10
General Information
Types QB, QMS, QL
600 Volts and Below

General Information Temperature Class


The complete family of transformers from GE provide quiet, Industry standards classify insulation systems in accordance with
reliable transformer operation. the rating system shown below.
All of the dry-type transformers through 1,000 kVA are UL listed Insulation System Classification
Ambient + Winding Rise + Hot Spot = Temp. Class
under the requirements of Standard 5085 and 1561. In addition, 40C 55C 10C 105C
each transformer meets the requirements of NEMA ST-20, 1992. 40C 80C 30C 150C
Type IP, QB and QMS models are C-UL listed. 40C 115C 25C 180C
40C 150C 30C 220C
General-purpose transformers are rated 600 Volts and below for All standard, general-purpose, GE transformers meet all applicable
supplying appliance, lighting, and power loads from electrical NEMA, ANSI, UL, and IEEE standards.
distribution systems. Standard distribution voltages are 600, 480,
The design life of transformers having different insulation systems
and 240 Volts; standard load voltages are 480, 240, 208, and 120
is the same, since the allowable temperature rise of an insulation
Volts. The transformer is used to obtain the load voltage from the
material system is predicated on a specified life for all insulation.
distribution voltage. Since no vaults are required for installation,
The lower temperature systems are designed for the same life as
these transformers can be located right at the load to provide
higher temperature systems.
the correct voltage for the application. This eliminates the need
for long, costly, low-voltage feeders.
Sound Levels
Construction All general-purpose transformers are as quiet, or quieter than
required by NEMA ST-20. Average sound levels are warranted not
Types QB and QMS
to exceed the values listed for each load rating shown in the
Core and coils are contained within a NEMA 3R nonventilated
adjacent table. Sound characteristics vary between transformers
weatherproof enclosure. Type QB and QMS units feature
of identical voltage and kVA rating. The range of variation may be
encapsulated core and coils.
4 to 8 decibels.
Type QL
These values apply only to specified test conditions because the
Units are enclosed in a NEMA 2 drip-proof painted metal enclo-
characteristic of the installation can cause them to be higher
sure with natural draft ventilation. The core-and-coil assembly is
under operating conditions. Where acoustical noise is deemed to
mounted on rubber isolation pads to reduce noise. Weathershield
be of unusual concern, proper steps should be taken during
kits are available for conversion to a NEMA 3R enclosure suitable
installation to minimize audible noise transmission.
for outdoor service. NEMA 2 and NEMA 3R stainless steel (Type
316) enclosures are available up to 150kVA. To specify a stainless
steel enclosure for an aluminum-wound transformer, substitute
Sound Levels (Decibels)1 for 150C Rise Models
the letter S in the fifth character of the GE product number. For
kVA Sound Levels
example, 9T10A1004 changes to 9T10S1004. For copper-wound 0-9 40
transformers, substitute the letter Z in the fifth character of the 10 - 50 45
51 - 150 50
GE product number. For example, 9T10C1004 changes to 151 - 300 55
9T10Z1004. All QL model product numbers begin with 9T7, 9T8, 301 - 500 60
or 9T1. 1Measured per NEMA ST-20.

Transformer taps compensate for high or low line voltages. Most


standard QL units rated 15kVA through 300kVA and with a pri-
mary voltage of 240V or higher have six available voltage taps
four 2.5% taps below the nominal tap and two 2.5% taps above
the nominal tap. This arrangement provides a 15% range of tap
voltage adjustment. Transformers rated 500kVA and higher have
four available voltage taps two 2.5% taps above the nominal
tap and two 2.5% taps below the nominal tap.

10-2 BuyLogTM Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Page Updated 09 / 2016

Dry Type Transformers Section 10


General Information
Types QB, QMS, QL
600 Volts and Below

Termination
Improved termination spacing and wiring compartment room
gives greater flexibility in selecting various UL listed connectors
for either copper or aluminum cable.

Product Number Selection Instructions


1. Establish phase and frequency
2. Determine the primary voltagethe voltage presently available
3. Determine the secondary voltagethe voltage needed at
the load
Type QB, .050 kVA-3 kVA, Single-Phase
4. Determine the kVA load, allowing room for expansion
5. Using the facts determined in the four steps, locate the
transformer model in the listings on the following pages.

Type QMS, 5 kVA-25 kVA, Single-Phase

Type QL, 15 kVA-250 kVA, Single-Phase, DOE 2016 Efficiency,


15 kVA-500 kVA, Three-Phase, DOE 2016 Efficiency

Rev. 11/13 www.geindustrial.com BuyLogTM Catalog 10-3


Data subject to change
without notice
Dry Type Transformers Section 10
General Purpose
Aluminum
Single-Phase DOE 2016 Efficiency

150C Rise NEMA 2


Input Output Wiring Approx. Net Frame Product
Voltage Voltage kVA Taps Diagram No.1 Weight (Lbs) Size Number
15 (+2, -4 2.5%) 23 320 YF171 9T83B2670
25 (+2, -4 2.5%) 23 320 YF171 9T83B2671
37.5 (+2, -4 2.5%) 23 320 YF171 9T83B2672
50 (+2, -4 2.5%) 23 400 YF172 9T83B2673
240 x 480 Volts 120/240 Volts
75 (+2, -4 2.5%) 23 510 YF174 9T83B2674
100 (+2, -4 2.5%) 23 900 YF175 9T83B2675
167 (+2, -4 2.5%) 23 1360 YF176 9T83B2676
250 (+2, -4 2.5%) 23 1700 YF177 9T83B2677

115C Rise NEMA 2


Input Output Wiring Approx. Net Frame Product
Voltage Voltage kVA Taps Diagram No.1 Weight (Lbs) Size Number
15 (+2, -4 2.5%) 23 320 YF171 9T83B2670G15
25 (+2, -4 2.5%) 23 320 YF171 9T83B2671G15
37.5 (+2, -4 2.5%) 23 400 YF172 9T83B2672G15
240 x 480 Volts 120/240 Volts 50 (+2, -4 2.5%) 23 500 XV173 9T83B2673G15
75 (+2, -4 2.5%) 23 510 YF174 9T83B2674G15
100 (+2, -4 2.5%) 23 900 YF175 9T83B2675G15
167 (+2, -4 2.5%) 23 1360 YF176 9T83B2676G15

80C Rise NEMA 2


Input Output Wiring Approx. Net Frame Product
Voltage Voltage kVA Taps Diagram No.1 Weight (Lbs) Size Number
15 (+2, -4 2.5%) 23 320 YF171 9T83B2670G80
25 (+2, -4 2.5%) 23 320 YF171 9T83B2671G80
37.5 (+2, -4 2.5%) 23 400 YF172 9T83B2672G80
240 x 480 Volts 120/240 Volts 50 (+2, -4 2.5%) 23 510 YF174 9T83B2673G80
75 (+2, -4 2.5%) 23 900 YF175 9T83B2674G80
100 (+2, -4 2.5%) 23 1360 YF176 9T83B2675G80
167 (+2, -4 2.5%) 23 1700 YF177 9T83B2676G80
1See page 10-45 for wiring diagrams.

10-4 BuyLogTM Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Dry Type Transformers Section 10
General Purpose
Copper
Single-Phase DOE 2016 Efficiency

150C Rise NEMA 2


Input Output Wiring Approx. Net Frame Product
Voltage Voltage kVA Taps Diagram No.1 Weight (Lbs) Size Number
15 (+2, -4 2.5%) 23 350 YF171 9T83C2570
25 (+2, -4 2.5%) 23 350 YF171 9T83C2571
37.5 (+2, -4 2.5%) 23 500 YF172 9T83C2572
240 x 480 Volts 120/240 Volts 50 (+2, -4 2.5%) 23 520 YF173 9T83C2573
75 (+2, -4 2.5%) 23 635 YF174 9T83C2574
100 (+2, -4 2.5%) 23 1050 YF175 9T83C2575
167 (+2, -4 2.5%) 23 1675 YF176 9T83C2576

115C Rise NEMA 2


Input Output Wiring Approx. Net Frame Product
Voltage Voltage kVA Taps Diagram No.1 Weight (Lbs) Size Number
15 (+2, -4 2.5%) 23 350 YF171 9T83C2570G15
25 (+2, -4 2.5%) 23 350 YF171 9T83C2571G15
37.5 (+2, -4 2.5%) 23 500 YF172 9T83C2572G15
240 x 480 Volts 120/240 Volts 50 (+2, -4 2.5%) 23 520 YF173 9T83C2573G15
75 (+2, -4 2.5%) 23 635 YF174 9T83C2574G15
100 (+2, -4 2.5%) 23 1050 YF175 9T83C2575G15
167 (+2, -4 2.5%) 23 1675 YF176 9T83C2576G15

80C Rise NEMA 2


Input Output Wiring Approx. Net Frame Product
Voltage Voltage kVA Taps Diagram No.1 Weight (Lbs) Size Number
15 (+2, -4 2.5%) 23 350 YF171 9T83C2570G80
25 (+2, -4 2.5%) 23 350 YF171 9T83C2571G80
37.5 (+2, -4 2.5%) 23 500 YF172 9T83C2572G80
240 x 480 Volts 120/240 Volts 50 (+2, -4 2.5%) 23 635 YF174 9T83C2573G80
75 (+2, -4 2.5%) 23 1050 YF175 9T83C2574G80
100 (+2, -4 2.5%) 23 1675 YF176 9T83C2575G80
167 (+2, -4 2.5%) 23 1960 YF177 9T83C2576G80
1See page 10-45 for wiring diagrams.

Rev. 11/13 www.geindustrial.com BuyLogTM Catalog 10-5


Data subject to change
without notice
Page Updated 09 / 2016

Dry Type Transformers Section 10


General Purpose
Three-Phase
DOE 2016 Product Number Nomenclature

9T 1 0 A 100 1 G31
GE Standard Group Number
No Group Number Shown = 150C G34 = 115C, Electrostatic Shield, -3dB
1 = QL DOE 2016 Design kVA Rating G02 = 150C, -3dB G35 = 115C, -5dB
1 = 15kVA G03 = 150C, Electrostatic Shield G36 = 115C, Electrostatic Shield, -5dB
Transformer Type 2 = 30kVA G04 = 150C, Electrostatic Shield, -3dB G39 = 115C, Non-STD kVA
0 = Standard, K1 3 = 45kVA G05 = 150C, -5dB G40 = 115C, Non-STD kVA
1 = K13 4 = 75kVA G06 = 150C, Electrostatic Shield, -5dB G61 = 80C
2 = K20 5 = 112.5kVA G09 = 150C, Non-STD kVA G62 = 80C, -3dB
3 = K30 6 = 150kVA G10 = 150C, Non-STD kVA G63 = 80C, Electrostatic Shield
4 = K4 7 = 225kVA G29 = 140C, 40C amb G64 = 80C, Electrostatic Shield, -3dB
7 = Guard II/Servicenter 8 = 300kVA G30 = 140C, 50C amb G65 = 80C, -5dB
8 = Spare Parts 9 = 500kVA G31 = 115C G66 = 80C, Electrostatic Shield, -5dB
G32 = 115C, -3dB G69 = 80C, Non-STD kVA
Coil Material G33 = 115C, Electrostatic Shield G70 = 80C, Non-STD kVA
A = Aluminum Voltage Rating An Electrostatic Shield (also called a Guard I transformer) is a grounded, copper-foil barrier between the primary
C = Copper See Voltage Chart below and secondary winding to reduce electrical noise. All K-Factor transformers contain an Electrostatic Shield.

3-Phase Common Voltages


Series Primary Voltage Secondary Voltage Series Primary Voltage Secondary Voltage Series Primary Voltage Secondary Voltage
100 480 208Y/120 157 240 575 212 400 480Y/277
101 480 220 158 240 460Y/266 213 415 208Y/120
102 480 220Y/127 159 240 240Y/139 214 415 460
103 480 208 160 240 600 215 415 220Y/127
104 480 230Y/133 161 240 208Y/120 216 416 208Y/120
105 480 240Y/139 162 240 380 217 416 480Y/277
106 480 380 163 240 440 218 460 208Y/120
107 480 380Y/219 164 240 240/120 219 460 220
108 480 400Y/231 165 240 380Y/219 221 460 400Y/231
109 480 415Y/240 166 220 380Y/219 222 460 220Y/127
110 480 480 167 220 400Y/231 223 460 230
111 480 575 168 220 240Y/139 224 460 575Y/332
112 480 600 169 220 220 225 460 230Y/133
113 480 440Y/254 170 220 208Y/120 226 460 460Y/266
114 480 600Y/346 171 220 480Y/277 227 550 208Y/120
115 480 440 172 220 440Y/254 228 550 480Y/277
116 480 230/115 173 220 480/240
229 575 208Y/120
117 480 480Y/277 174 220 480
230 575 480Y/277
118 480 240/120 175 220 415Y/240
231 575 240Y/139
119 480 240 176 380 220Y/127 232 575 460
121 480 220/110 177 380 480 233 575 480
123 480 400 178 380 220 234 575 230Y/133
124 480 460 179 380 208Y/120 235 575 230
125 480 420 180 380 415Y/240
236 600 240/120
126 480 230 181 380 240/120
237 600 480
127 480 575Y/332 184 380 480Y/277
238 600 480Y/277
129 480 460Y/266 185 380 380Y/219
239 600 240
131 208 240 186 380 230Y/133
240 600 208Y/120
132 208 240/120 187 380 240
241 600 230Y/133
133 208 480 188 440 220Y/127 242 600 240Y/139
134 208 480Y/277 189 440 480 243 600 208
135 208 380Y/219 190 440 208Y/120 244 600 600Y/346
136 208 230 191 440 380
245 690 400Y/231
137 208 575 192 440 380Y/219
246 690 208Y/120
138 208 460 193 440 400Y/231
247 277 415Y/240
139 208 400Y/231 194 440 575Y/332
248 315 208Y/120
140 208 208 195 440 240/120
249 320 480Y/277
141 208 230Y/133 196 440 480Y/277
250 420 480Y/277
142 208 380 197 440 240
251 490 480Y/277
143 208 220/110 198 230 460
252 500 480Y/277
144 208 220Y/127 199 230 400Y/231
145 208 208Y/120 200 230 400
146 208 400 201 230 480Y/277
147 208 315 202 230 208Y/120
148 208 600 203 230 480
149 208 460Y/266 204 400 230Y/133
150 208 220 205 400 380Y/219
151 208 230/115 206 400 480
152 208 415Y/240 207 400 220Y/127
153 240 480Y/277 209 400 400Y/231
154 240 480 210 400 208Y/120
155 240 400Y/231 211 400 208Y/120

10-6 BuyLogTM Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Dry Type Transformers Section 10
General Purpose
Three-Phase
DOE 2016 Product Number Nomenclature

3P Servicenter Product Numbers DOE 2016


Material KVA Primary Voltage Secondary Voltage Product Number
15 240 208Y/120 9T17A0001
22.5 240 208Y/120 9T17A0002
30 240 208Y/120 9T17A0003
15 480 208Y/120 9T17A0011
AL 22.5 480 208Y/120 9T17A0012
30 480 208Y/120 9T17A0013
15 600 208Y/120 9T17A0021
22.5 600 208Y/120 9T17A0022
30 600 208Y/120 9T17A0023
15 240 208Y/120 9T17C0004
22.5 240 208Y/120 9T17C0005
30 240 208Y/120 9T17C0006
15 480 208Y/120 9T17C0014
CU 22.5 480 208Y/120 9T17C0015
30 480 208Y/120 9T17C0016
15 600 208Y/120 9T17C0024
22.5 600 208Y/120 9T17C0025
30 600 208Y/120 9T17C0026

Guard II Product Numbers DOE 2016


Material KVA Primary Voltage Secondary Voltage Product Number
15 480 208Y/120 9T17A1001G03
30 480 208Y/120 9T17A1002G03
AL 45 480 208Y/120 9T17A1003G03
75 480 208Y/120 9T17A1004G03
112.5 480 208Y/120 9T17A1005G03
15 480 208Y/120 9T17C1001G03
30 480 208Y/120 9T17C1002G03
CU 45 480 208Y/120 9T17C1003G03
75 480 208Y/120 9T17C1004G03
112.5 480 208Y/120 9T17C1005G03

Rev. 11/13 www.geindustrial.com BuyLogTM Catalog 10-7


Data subject to change
without notice
Dry Type Transformers Section 10
General Purpose
Aluminum
Three-Phase DOE 2016 Efficiency

Advantages
Quiet performance
No-weld design an industry first
Comprehensive factory testing assures quality
Accessible mounting foot design speeds installation
Lug kit and ground bar kit included up through 150kVA
GEs exclusive wood crate packaging helps reduce
shipping damage

Key Features
Unique core and coil design makes QL transformers among the
quietest available Type QL Transformer
Core and coil assemblies are mounted on rubber isolation pads
to reduce noise Seismic qualified to the requirements of ASCE 7.05,
Bolted coil terminations are more reliable than welded termina- IEEE-693-2005 and IBC-2012/CBC-2013
tions, and they eliminate weld failures and problems associated Copper or aluminum windings
with welding and weld splatter Copper ground strap
Single-piece front/back is easily removable for service Robust packaging with top and side protection protects against
Accessible mounting flanges with front/back slotted mounting shipping damage
holes make installation easier
100% factory tested for shorts and coil integrity, current and Applications
loss, voltage, impedance and noise. Commercial
NEMA 2 powder-coat drip-proof enclosure is standard. Industrial
Weathershield kit is available for conversion to NEMA 3R Motors
outdoor. Incandescent lighting
NEMA 3R stainless steel enclosure is available up to 150kVA. Resistance heating
To specify a stainless steel enclosure, substitute an S in the Motor generators (without solid state drives)
fifth character in the GE catalog number.
Example: 9T10A1004 changes to 9T10S1004.
Transformer Selection Guide
(type 316) Enclosure
K -Factor (K=13)

K -Factor (K=20)

K -Factor (K=30)
K -Factor (K=4)

Service Center

Stainless Steel
Standard

Guard III
Guard II
Guard I

TENV
DIT

Motors X X X
Incandescent Lighting X X X
Resistance Heating X X X
Motor Generators (without solid state drives) X X X
HID Lighting X
Induction Heaters X
Welders X
UPS with optional input filtering X
PLC & Solid state controls X
Multiple receptacle circuits in heath care facilities X
UPS without optional input filtering X
Production or assembly line equipment X
Schools & Classroom facilities X
Surge Supression X
Office Buildings X X X X
SCR Variable Speed Drives X X
Circuits with exclusive data processing equipment X X X X
Critical Care facilities X X X X
Hospital Operating Rooms X X X X
X-ray equipment X X X X
Computer Installations X X X X
Programmable Controllers X X X X
Instrumentation X X X X
AC or DC Variable Speed Drives X
Rectifier outputs X
Temporary Power X
Airborne contamins or dust-laden environments (indoor and outdoor) X
Corrosive environments including water/wastewater and salt spray X

10-8 BuyLogTM Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Dry Type Transformers Section 10
General Purpose
Aluminum
Three-Phase DOE 2016 Efficiency

Type QL Transformer

150C Rise NEMA 2


Input Output Wiring Approx. Net Frame Product
Voltage Voltage kVA Taps Diagram No.1 Weight (Lbs) Size Number
15 (+2, -4 2.5%) 12 231 UX71A 9T10A1001
30 (+2, -4 2.5%) 12 330 UX72A 9T10A1002
45 (+2, -4 2.5%) 12 444 UX73A 9T10A1003
75 (+2, -4 2.5%) 12 561 UY74A 9T10A1004
480 Volts Delta 208Y/120 Volts 112.5 (+2, -4 2.5%) 12 680 DY75A 9T10A1005
150 (+2, -4 2.5%) 12 1030 DY76A 9T10A1006
225 (+2, -4 2.5%) 12 1450 DY77A 9T10A1007
300 (+2, -4 2.5%) 12 1670 DY78A 9T10A1008
500 (+2, -2 2.5%) 12 2900 DX79A 9T10A1009

115C Rise NEMA 2


Input Output Wiring Approx. Net Frame Product
Voltage Voltage kVA Taps Diagram No.1 Weight (Lbs) Size Number
15 (+2, -4 2.5%) 12 231 UX71A 9T10A1001G31
30 (+2, -4 2.5%) 12 330 UX72A 9T10A1002G31
45 (+2, -4 2.5%) 12 444 UX73A 9T10A1003G31
75 (+2, -4 2.5%) 12 603 UX74A 9T10A1004G31
480 Volts Delta 208Y/120 Volts 112.5 (+2, -4 2.5%) 12 830 DX75A 9T10A1005G31
150 (+2, -4 2.5%) 12 1250 DX76A 9T10A1006G31
225 (+2, -4 2.5%) 12 1670 DX77A 9T10A1007G31
300 (+2, -4 2.5%) 12 1985 DX78A 9T10A1008G31
500 (+2, -2 2.5%) 12 2900 DX79A 9T10A1009G31

80C Rise NEMA 2


Input Output Wiring Approx. Net Frame Product
Voltage Voltage kVA Taps Diagram No.1 Weight (Lbs) Size Number
15 (+2, -4 2.5%) 12 330 UX72A 9T10A1001G61
30 (+2, -4 2.5%) 12 444 UX73A 9T10A1002G61
45 (+2, -4 2.5%) 12 561 UY74A 9T10A1003G61
75 (+2, -4 2.5%) 12 680 DY75A 9T10A1004G61
480 Volts Delta 208Y/120 Volts
112.5 (+2, -4 2.5%) 12 1030 DY76A 9T10A1005G61
150 (+2, -4 2.5%) 12 1450 DY77A 9T10A1006G61
225 (+2, -4 2.5%) 12 1985 DX78A 9T10A1007G61
300 (+2, -2 2.5%) 12 2900 DX79A 9T10A1008G61

150C Rise NEMA 2


Input Output Wiring Approx. Net Frame Product
Voltage Voltage kVA Taps Diagram No.1 Weight (Lbs) Size Number
15 (+2, -4 2.5%) 12 231 UX71A 9T10A1451
30 (+2, -4 2.5%) 12 330 UX72A 9T10A1452
45 (+2, -4 2.5%) 12 561 UY74A 9T10A1453
75 (+2, -4 2.5%) 12 680 DY75A 9T10A1454
208 Volts Delta 208Y/120 Volts
112.5 (+2, -4 2.5%) 12 1030 DY76A 9T10A1455
150 (+2, -4 2.5%) 12 1250 DX76A 9T10A1456
225 (+2, -4 2.5%) 12 1670 DY78A 9T10A1457
300 (+2, -2 2.5%) 12 2900 DX79A 9T10A1458
1See page 10-45 for wiring diagrams.

Rev. 11/13 www.geindustrial.com BuyLogTM Catalog 10-9


Data subject to change
without notice
Dry Type Transformers Section 10
General Purpose
Aluminum
Three-Phase DOE 2016 Efficiency

150C Rise NEMA 2


Input Output Wiring Approx. Net Frame Product
Voltage Voltage kVA Taps Diagram No.1 Weight (Lbs) Size Number
15 (+2, -4 2.5%) 12 231 UX71A 9T10A1341
30 (+2, -4 2.5%) 12 330 UX72A 9T10A1342
45 (+2, -4 2.5%) 12 561 UY74A 9T10A1343
75 (+2, -4 2.5%) 12 680 UY74A 9T10A1344
208 Volts Delta 480Y/277 Volts
112.5 (+2, -4 2.5%) 12 1030 DY76A 9T10A1345
150 (+2, -4 2.5%) 12 1250 DX76A 9T10A1346
225 (+2, -4 2.5%) 12 1670 DY78A 9T10A1347
300 (+2, -2 2.5%) 12 2900 DX79A 9T10A1348

150C Rise NEMA 2


Input Output Wiring Approx. Net Frame Product
Voltage Voltage kVA Taps Diagram No.1 Weight (Lbs) Size Number
15 (+2, -4 2.5%) 12 231 UX71A 9T10A1611
30 (+2, -4 2.5%) 12 330 UX72A 9T10A1612
45 (+2, -4 2.5%) 12 444 UX73A 9T10A1613
75 (+2, -4 2.5%) 12 561 UY74A 9T10A1614
240 Volts Delta 208Y/120 Volts 112.5 (+2, -4 2.5%) 12 680 DY75A 9T10A1615
150 (+2, -4 2.5%) 12 1030 DY76A 9T10A1616
225 (+2, -4 2.5%) 12 1450 DY77A 9T10A1617
300 (+2, -4 2.5%) 12 1670 DY78A 9T10A1618
500 (+2, -2 2.5%) 12 2900 DX79A 9T10A1619

150C Rise NEMA 2


Input Output Wiring Approx. Net Frame Product
Voltage Voltage kVA Taps Diagram No.1 Weight (Lbs) Size Number
15 (+2, -4 2.5%) 12 231 UX71A 9T10A1531
30 (+2, -4 2.5%) 12 330 UX72A 9T10A1532
45 (+2, -4 2.5%) 12 444 UX73A 9T10A1533
75 (+2, -4 2.5%) 12 561 UY74A 9T10A1534
240 Volts Delta 480Y/277 Volts 112.5 (+2, -4 2.5%) 12 680 DY75A 9T10A1535
150 (+2, -4 2.5%) 12 1030 DY76A 9T10A1536
225 (+2, -4 2.5%) 12 1450 DY77A 9T10A1537
300 (+2, -4 2.5%) 12 1670 DY78A 9T10A1538
500 (+2, -2 2.5%) 12 2900 DX79A 9T10A1539

150C Rise NEMA 2


Input Output Wiring Approx. Net Frame Product
Voltage Voltage kVA Taps Diagram No.1 Weight (Lbs) Size Number
15 (+2, -4 2.5%) 19 231 UX71A 9T10A1181
30 (+2, -4 2.5%) 19 330 UX72A 9T10A1182
45 (+2, -4 2.5%) 19 444 UX73A 9T10A1183
75 (+2, -4 2.5%) 19 561 UY74A 9T10A1184
480 Volts Delta 240/120 Volts 112.5 (+2, -4 2.5%) 19 830 DX75A 9T10A1185
150 (+2, -4 2.5%) 19 1030 DY76A 9T10A1186
225 (+2, -4 2.5%) 19 1450 DY77A 9T10A1187
300 (+2, -4 2.5%) 19 1670 DY78A 9T10A1188
500 (+2, -2 2.5%) 19 2900 DX79A 9T10A1189

150C Rise NEMA 2


Input Output Wiring Approx. Net Frame Product
Voltage Voltage kVA Taps Diagram No.1 Weight (Lbs) Size Number
15 (+2, -4 2.5%) 12 231 UX71A 9T10A1171
30 (+2, -4 2.5%) 12 330 UX72A 9T10A1172
45 (+2, -4 2.5%) 12 444 UX73A 9T10A1173
75 (+2, -4 2.5%) 12 561 UY74A 9T10A1174
480 Volts Delta 480Y/277 Volts 112.5 (+2, -4 2.5%) 12 680 DY75A 9T10A1175
150 (+2, -4 2.5%) 12 1030 DY76A 9T10A1176
225 (+2, -4 2.5%) 12 1450 DY77A 9T10A1177
300 (+2, -4 2.5%) 12 1670 DY78A 9T10A1178
500 (+2, -2 2.5%) 12 2900 DX79A 9T10A1179
1See page 10-45 for wiring diagrams.

10-10 BuyLogTM Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Dry Type Transformers Section 10
General Purpose
Copper
Three-Phase DOE 2016 Efficiency

150C Rise NEMA 2


Input Output Wiring Approx. Net Frame Product
Voltage Voltage kVA Taps Diagram No.1 Weight (Lbs) Size Number
15 (+2, -4 2.5%) 13 230 UX71C 9T10C1191
30 (+2, -4 2.5%) 13 353 UX72C 9T10C1192
45 (+2, -4 2.5%) 13 480 UX73C 9T10C1193
75 (+2, -4 2.5%) 13 661 UY74C 9T10C1194
480 Volts Delta 240 Volts 112.5 (+2, -4 2.5%) 13 790 DY75C 9T10C1195
150 (+2, -4 2.5%) 13 1085 DY76C 9T10C1196
225 (+2, -4 2.5%) 13 1610 DY77C 9T10C1197
300 (+2, -4 2.5%) 13 1970 DY78C 9T10C1198
500 (+2, -2 2.5%) 13 3720 DX79C 9T10C1199

150C Rise NEMA 2


Input Output Wiring Approx. Net Frame Product
Voltage Voltage kVA Taps Diagram No.1 Weight (Lbs) Size Number
15 (+2, -4 2.5%) 12 230 UX71C 9T10C2401
30 (+2, -4 2.5%) 12 353 UX72C 9T10C2402
45 (+2, -4 2.5%) 12 480 UX73C 9T10C2403
75 (+2, -4 2.5%) 12 661 UY74C 9T10C2404
600 Volts Delta 208Y/120 Volts 112.5 (+2, -4 2.5%) 12 790 DY75C 9T10C2405
150 (+2, -4 2.5%) 12 1085 DY76C 9T10C2406
225 (+2, -4 2.5%) 12 1610 DY77C 9T10C2407
300 (+2, -4 2.5%) 12 1970 DY78C 9T10C2408
500 (+2, -2 2.5%) 12 3720 DX79C 9T10C2409

150C Rise NEMA 2


Input Output Wiring Approx. Net Frame Product
Voltage Voltage kVA Taps Diagram No.1 Weight (Lbs) Size Number
15 (+2, -4 2.5%) 12 230 UX71C 9T10C1001
30 (+2, -4 2.5%) 12 353 UX72C 9T10C1002
45 (+2, -4 2.5%) 12 480 UX73C 9T10C1003
75 (+2, -4 2.5%) 12 661 UY74C 9T10C1004
480 Volts Delta 208Y/120 Volts 112.5 (+2, -4 2.5%) 12 790 DY75C 9T10C1005
150 (+2, -4 2.5%) 12 1085 DY76C 9T10C1006
225 (+2, -4 2.5%) 12 1610 DY77C 9T10C1007
300 (+2, -4 2.5%) 12 1970 DY78C 9T10C1008
500 (+2, -2 2.5%) 12 3720 DX79C 9T10C1009

115C Rise NEMA 2


Input Output Wiring Approx. Net Frame Product
Voltage Voltage kVA Taps Diagram No.1 Weight (Lbs) Size Number
15 (+2, -4 2.5%) 12 230 UX71C 9T10C1001G31
30 (+2, -4 2.5%) 12 353 UX72C 9T10C1002G31
45 (+2, -4 2.5%) 12 480 UX73C 9T10C1003G31
75 (+2, -4 2.5%) 12 748 UX74C 9T10C1004G31
480 Volts Delta 208Y/120 Volts
112.5 (+2, -4 2.5%) 12 900 DX75C 9T10C1005G31
150 (+2, -4 2.5%) 12 1240 DX76C 9T10C1006G31
225 (+2, -4 2.5%) 12 1847 DX77C 9T10C1007G31
300 (+2, -4 2.5%) 12 2150 DX78C 9T10C1008G31

80C Rise NEMA 2


Input Output Wiring Approx. Net Frame Product
Voltage Voltage kVA Taps Diagram No.1 Weight (Lbs) Size Number
15 (+2, -4 2.5%) 12 353 UX72C 9T10C1001G61
30 (+2, -4 2.5%) 12 480 UX73C 9T10C1002G61
45 (+2, -4 2.5%) 12 661 UY74C 9T10C1003G61
480 Volts Delta 208Y/120 Volts 75 (+2, -4 2.5%) 12 790 DY75C 9T10C1004G61
112.5 (+2, -4 2.5%) 12 1085 DY76C 9T10C1005G61
150 (+2, -4 2.5%) 12 1610 DY77C 9T10C1006G61
225 (+2, -4 2.5%) 12 2150 DX78C 9T10C1007G61
300 (+2, -2 2.5%) 12 3720 DX79C 9T10C1008G61
1See page 10-45 for wiring diagrams.

Rev. 11/13 www.geindustrial.com BuyLog Catalog 10-11


Prices and data subject
to change without notice
Dry Type Transformers Section 10
K-Factor
Aluminum
Three-Phase DOE 2016 Efficiency

Product Description
These type QL transformers have passed the UL K-factor testing
program. K-factor is a standardized way to indicate the ability of
a transformer to withstand harmonics. These units shall not
exceed rated winding temperature rise at full load and rated K-
factor. Neutrals are capable of handling 200% of rated secondary
phase current.
Full-width copper electrostatic shielding is standard on all GE
K-factor rated transformers. Effective coupling capacitance is
30 pf. Common mode noise attenuation averages 120 dB, and
transverse mode noise attenuation averages 30 dB.

Application
For commercial applications with significant nonlinear electronic
loading, use K=4 for systems with 50% connected nonlinear elec-
tronic loads; K=13 for systems with 100% connected nonlinear
electronic loads.
Higher K-factor rated units are available for unique applications. Type QL, UL K-Factor Transformer

K=4 150C Rise NEMA 2


Input Output Wiring Approx. Net Frame Product
Voltage Voltage kVA Taps Diagram No.1 Weight (Lbs) Size Number
15 (+2, -4 2.5%) 12 231 UX71A 9T14A1001G03
30 (+2, -4 2.5%) 12 444 UX73A 9T14A1002G03
45 (+2, -4 2.5%) 12 444 UX73A 9T14A1003G03
75 (+2, -4 2.5%) 12 680 DY75A 9T14A1004G03
480 Volts Delta 208Y/120 Volts
112.5 (+2, -4 2.5%) 12 1030 DY76A 9T14A1005G03
150 (+2, -4 2.5%) 12 1250 DX76A 9T14A1006G03
225 (+2, -4 2.5%) 12 1670 DY78A 9T14A1007G03
300 (+2, -2 2.5%) 12 2900 DX79A 9T14A1008G03

K=4 115C Rise NEMA 2


Input Output Wiring Approx. Net Frame Product
Voltage Voltage kVA Taps Diagram No.1 Weight (Lbs) Size Number
15 (+2, -4 2.5%) 12 231 UX71A 9T14A1001G33
30 (+2, -4 2.5%) 12 444 UX73A 9T14A1002G33
45 (+2, -4 2.5%) 12 561 UY74A 9T14A1003G33
75 (+2, -4 2.5%) 12 680 DY75A 9T14A1004G33
480 Volts Delta 208Y/120 Volts
112.5 (+2, -4 2.5%) 12 1030 DY76A 9T14A1005G33
150 (+2, -4 2.5%) 12 1250 DX76A 9T14A1006G33
225 (+2, -4 2.5%) 12 1670 DY78A 9T14A1007G33
300 (+2, -2 2.5%) 12 2900 DX79A 9T14A1008G33

K=4 80C Rise NEMA 2


Input Output Wiring Approx. Net Frame Product
Voltage Voltage kVA Taps Diagram No.1 Weight (Lbs) Size Number
15 (+2, -4 2.5%) 12 330 UX72A 9T14A1001G63
30 (+2, -4 2.5%) 12 444 UX73A 9T14A1002G63
45 (+2, -4 2.5%) 12 561 UY74A 9T14A1003G63
480 Volts Delta 208Y/120 Volts 75 (+2, -4 2.5%) 12 830 DX75A 9T14A1004G63
112.5 (+2, -4 2.5%) 12 1250 DX76A 9T14A1005G63
150 (+2, -4 2.5%) 12 1670 DX77A 9T14A1006G63
225 (+2, -4 2.5%) 12 1670 DY78A 9T14A1007G63
1See page 10-45 for wiring diagrams.

10-12 BuyLogTM Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Dry Type Transformers Section 10
K-Factor
Aluminum
Three-Phase DOE 2016 Efficiency

K=13 150C Rise NEMA 2


Input Output Wiring Approx. Net Frame Product
Voltage Voltage kVA Taps Diagram No.1 Weight (Lbs) Size Number
15 (+2, -4 2.5%) 12 231 UX71A 9T11A1001G03
30 (+2, -4 2.5%) 12 444 UX73A 9T11A1002G03
45 (+2, -4 2.5%) 12 444 UX73A 9T11A1003G03
75 (+2, -4 2.5%) 12 603 UX74A 9T11A1004G03
480 Volts Delta 208Y/120 Volts
112.5 (+2, -4 2.5%) 12 1030 DY76A 9T11A1005G03
150 (+2, -4 2.5%) 12 1250 DX76A 9T11A1006G03
225 (+2, -4 2.5%) 12 1670 DY78A 9T11A1007G03
300 (+2, -2 2.5%) 12 2900 DX79A 9T11A1008G03

K=13 115C Rise NEMA 2


Input Output Wiring Approx. Net Frame Product
Voltage Voltage kVA Taps Diagram No.1 Weight (Lbs) Size Number
15 (+2, -4 2.5%) 12 231 UX71A 9T11A1001G33
30 (+2, -4 2.5%) 12 444 UX73A 9T11A1002G33
45 (+2, -4 2.5%) 12 561 UY74A 9T11A1003G33
75 (+2, -4 2.5%) 12 680 DY75A 9T11A1004G33
480 Volts Delta 208Y/120 Volts
112.5 (+2, -4 2.5%) 12 1250 DX76A 9T11A1005G33
150 (+2, -4 2.5%) 12 1450 DY77A 9T11A1006G33
225 (+2, -4 2.5%) 12 1670 DY78A 9T11A1007G33
300 (+2,-2 2.5%) 12 2900 DX79A 9T11A1008G33

K=13 80C Rise NEMA 2


Input Output Wiring Approx. Net Frame Product
Voltage Voltage kVA Taps Diagram No.1 Weight (Lbs) Size Number
15 (+2, -4 2.5%) 12 330 UX72A 9T11A1001G63
30 (+2, -4 2.5%) 12 561 UY74A 9T11A1002G63
45 (+2, -4 2.5%) 12 561 UY74A 9T11A1003G63
75 (+2, -4 2.5%) 12 830 DX75A 9T11A1004G63
480 Volts Delta 208Y/120 Volts
112.5 (+2, -4 2.5%) 12 1670 DX77A 9T11A1005G63
150 (+2, -4 2.5%) 12 1670 DY78A 9T11A1006G63
225 (+2, -2 2.5%) 12 2900 DX79A 9T11A1007G63
1See page 10-45 for wiring diagrams.

Rev. 11/13 www.geindustrial.com BuyLogTM Catalog 10-13


Data subject to change
without notice
Dry Type Transformers Section 10
K-Factor
Aluminum
Three-Phase DOE 2016 Efficiency

K=20 150C Rise NEMA 2


Input Output Wiring Approx. Net Frame Product
Voltage Voltage kVA Taps Diagram No.1 Weight (Lbs) Size Number
15 (+2, -4 2.5%) 12 2 2 9T12A1001G03
30 (+2, -4 2.5%) 12 2 2 9T12A1002G03
45 (+2, -4 2.5%) 12 2 2 9T12A1003G03
75 (+2, -4 2.5%) 12 2 2 9T12A1004G03
480 Volts Delta 208Y/120 Volts
112.5 (+2, -4 2.5%) 12 2 2 9T12A1005G03
150 (+2, -4 2.5%) 12 2 2 9T12A1006G03
225 (+2, -4 2.5%) 12 2 2 9T12A1007G03
300 (+2, -4 2.5%) 12 2 2 9T12A1008G03

K=20 115C Rise NEMA 2


Input Output Wiring Approx. Net Frame Product
Voltage Voltage kVA Taps Diagram No.1 Weight (Lbs) Size Number
15 (+2, -4 2.5%) 12 2 2 9T12A1001G33
30 (+2, -4 2.5%) 12 2 2 9T12A1002G33
45 (+2, -4 2.5%) 12 2 2 9T12A1003G33
75 (+2, -4 2.5%) 12 2 2 9T12A1004G33
480 Volts Delta 208Y/120 Volts
112.5 (+2, -4 2.5%) 12 2 2 9T12A1005G33
150 (+2, -4 2.5%) 12 2 2 9T12A1006G33
225 (+2, -4 2.5%) 12 2 2 9T12A1007G33
300 (+2, -4 2.5%) 12 2 2 9T12A1008G33

K=20 80C Rise NEMA 2


Input Output Wiring Approx. Net Frame Product
Voltage Voltage kVA Taps Diagram No.1 Weight (Lbs) Size Number
15 (+2, -4 2.5%) 12 2 2 9T12A1001G63
30 (+2, -4 2.5%) 12 2 2 9T12A1002G63
45 (+2, -4 2.5%) 12 2 2 9T12A1003G63
75 (+2, -4 2.5%) 12 2 2 9T12A1004G63
480 Volts Delta 208Y/120 Volts
112.5 (+2, -4 2.5%) 12 2 2 9T12A1005G63
150 (+2, -4 2.5%) 12 2 2 9T12A1006G63
225 (+2, -4 2.5%) 12 2 2 9T12A1007G63
300 (+2, -4 2.5%) 12 2 2 9T12A1008G63
1See page 10-45 for wiring diagrams.
2Call GE Technical Support at 1-800-GE 1-STOP, Option #4

10-14 BuyLogTM Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Page Updated 09 / 2016

Dry Type Transformers Section 10


K-Factor
Aluminum
Three-Phase DOE 2016 Efficiency

K=30 150C Rise NEMA 2


Input Output Wiring Approx. Net Frame Product
Voltage Voltage kVA Taps Diagram No.1 Weight (Lbs) Size Number
15 (+2, -4 2.5%) 12 2 2 9T13A1001G03
30 (+2, -4 2.5%) 12 2 2 9T13A1002G03
45 (+2, -4 2.5%) 12 2 2 9T13A1003G03
75 (+2, -4 2.5%) 12 2 2 9T13A1004G03
480 Volts Delta 208Y/120 Volts
112.5 (+2, -4 2.5%) 12 2 2 9T13A1005G03
150 (+2, -4 2.5%) 12 2 2 9T13A1006G03
225 (+2, -4 2.5%) 12 2 2 9T13A1007G03
300 (+2, -4 2.5%) 12 2 2 9T13A1008G03

K=30 115C Rise NEMA 2


Input Output Wiring Approx. Net Frame Product
Voltage Voltage kVA Taps Diagram No.1 Weight (Lbs) Size Number
15 (+2, -4 2.5%) 12 2 2 9T13A1001G33
30 (+2, -4 2.5%) 12 2 2 9T13A1002G33
45 (+2, -4 2.5%) 12 2 2 9T13A1003G33
75 (+2, -4 2.5%) 12 2 2 9T13A1004G33
480 Volts Delta 208Y/120 Volts
112.5 (+2, -4 2.5%) 12 2 2 9T13A1005G33
150 (+2, -4 2.5%) 12 2 2 9T13A1006G33
225 (+2, -4 2.5%) 12 2 2 9T13A1007G33
300 (+2, -4 2.5%) 12 2 2 9T13A1008G33

K=30 80C Rise NEMA 2


Input Output Wiring Approx. Net Frame Product
Voltage Voltage kVA Taps Diagram No.1 Weight (Lbs) Size Number
15 (+2, -4 2.5%) 12 2 2 9T13A1001G63
30 (+2, -4 2.5%) 12 2 2 9T13A1002G63
45 (+2, -4 2.5%) 12 2 2 9T13A1003G63
75 (+2, -4 2.5%) 12 2 2 9T13A1004G63
480 Volts Delta 208Y/120 Volts
112.5 (+2, -4 2.5%) 12 2 2 9T13A1005G63
150 (+2, -4 2.5%) 12 2 2 9T13A1006G63
225 (+2, -4 2.5%) 12 2 2 9T13A1007G63
300 (+2, -4 2.5%) 12 2 2 9T13A1008G63
1See page 10-45 for wiring diagrams.
2Call GE Technical Support at 1-800-GE 1-STOP, Option #4

Rev. 11/13 www.geindustrial.com BuyLogTM Catalog 10-15


Data subject to change
without notice
Dry Type Transformers Section 10
K-Factor
Copper
Three-Phase DOE 2016 Efficiency

K=4 150C Rise NEMA 2


Input Output Wiring Approx. Net Frame Product
Voltage Voltage kVA Taps Diagram No.1 Weight (Lbs) Size Number
15 (+2, -4 2.5%) 12 230 UX71C 9T14C1001G03
30 (+2, -4 2.5%) 12 353 UX72C 9T14C1002G03
45 (+2, -4 2.5%) 12 480 UX73C 9T14C1003G03
75 (+2, -4 2.5%) 12 661 UY74C 9T14C1004G03
480 Volts Delta 208Y/120 Volts 112.5 (+2, -4 2.5%) 12 790 DY75C 9T14C1005G03
150 (+2, -4 2.5%) 12 1610 DY77C 9T14C1006G03
225 (+2, -4 2.5%) 12 1847 DX77C 9T14C1007G03
300 (+2, -2 2.5%) 12 3720 DX79C 9T14C1008G03

K=4 115C Rise NEMA 2


Input Output Wiring Approx. Net Frame Product
Voltage Voltage kVA Taps Diagram No.1 Weight (Lbs) Size Number
15 (+2, -4 2.5%) 12 353 UX72C 9T14C1001G33
30 (+2, -4 2.5%) 12 480 UX73C 9T14C1002G33
45 (+2, -4 2.5%) 12 661 UY74C 9T14C1003G33
75 (+2, -4 2.5%) 12 748 UX74C 9T14C1004G33
480 Volts Delta 208Y/120 Volts 112.5 (+2, -4 2.5%) 12 900 DX75C 9T14C1005G33
150 (+2, -4 2.5%) 12 1610 DY77C 9T14C1006G33
225 (+2, -4 2.5%) 12 2150 DX78C 9T14C1007G33
300 (+2, -2 2.5%) 12 3720 DX79C 9T14C1008G33
500 (+2, -2 2.5%) 12 2 2 9T14C1009G33

K=4 80C Rise NEMA 2


Input Output Wiring Approx. Net Frame Product
Voltage Voltage kVA Taps Diagram No.1 Weight (Lbs) Size Number
15 (+2, -4 2.5%) 12 353 UX72C 9T14C1001G63
30 (+2, -4 2.5%) 12 480 UX73C 9T14C1002G63
45 (+2, -4 2.5%) 12 661 UY74C 9T14C1003G63
75 (+2, -4 2.5%) 12 790 DY75C 9T14C1004G63
480 Volts Delta 208Y/120 Volts 112.5 (+2, -4 2.5%) 12 1085 DY76C 9T14C1005G63
150 (+2, -4 2.5%) 12 1610 DY77C 9T14C1006G63
225 (+2, -4 2.5%) 12 2150 DX78C 9T14C1007G63
300 (+2, -2 2.5%) 12 3720 DX79C 9T14C1008G63
1See page 10-45 for wiring diagrams.
2Call GE Technical Support at 1-800-GE 1-STOP, Option #4

10-16 BuyLogTM Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Dry Type Transformers Section 10
K-Factor
Copper
Three-Phase DOE 2016 Efficiency

K=13 150C Rise NEMA 2


Input Output Wiring Approx. Net Frame Product
Voltage Voltage kVA Taps Diagram No.1 Weight (Lbs) Size Number
15 (+2, -4 2.5%) 12 230 UX71C 9T11C1001G03
30 (+2, -4 2.5%) 12 353 UX72C 9T11C1002G03
45 (+2, -4 2.5%) 12 480 UX73C 9T11C1003G03
75 (+2, -4 2.5%) 12 790 DY75C 9T11C1004G03
480 Volts Delta 208Y/120 Volts 112.5 (+2, -4 2.5%) 12 790 DY75C 9T11C1005G03
150 (+2, -4 2.5%) 12 1610 DY77C 9T11C1006G03
225 (+2, -4 2.5%) 12 2150 DX78C 9T11C1007G03
300 (+2, -2 2.5%) 12 3720 DX79C 9T11C1008G03

K=13 115C Rise NEMA 2


Input Output Wiring Approx. Net Frame Product
Voltage Voltage kVA Taps Diagram No.1 Weight (Lbs) Size Number
15 (+2, -4 2.5%) 12 353 UX72C 9T11C1001G33
30 (+2, -4 2.5%) 12 480 UX73C 9T11C1002G33
45 (+2, -4 2.5%) 12 661 UY74C 9T11C1003G33
75 (+2, -4 2.5%) 12 790 DY75C 9T11C1004G33
480 Volts Delta 208Y/120 Volts 112.5 (+2, -4 2.5%) 12 1085 DY76C 9T11C1005G33
150 (+2, -4 2.5%) 12 1610 DY77C 9T11C1006G33
225 (+2, -4 2.5%) 12 3720 DX79C 9T11C1007G33
300 (+2, -2 2.5%) 12 3720 DX79C 9T11C1008G33
500 (+2, -2 2.5%) 12 2 2 9T11C1009G33

K=13 80C Rise NEMA 2


Input Output Wiring Approx. Net Frame Product
Voltage Voltage kVA Taps Diagram No.1 Weight (Lbs) Size Number
15 (+2, -4 2.5%) 12 353 UX72C 9T11C1001G63
30 (+2, -4 2.5%) 12 480 UX73C 9T11C1002G63
45 (+2, -4 2.5%) 12 661 UY74C 9T11C1003G63
75 (+2, -4 2.5%) 12 790 DY75C 9T11C1004G63
480 Volts Delta 208Y/120 Volts
112.5 (+2, -4 2.5%) 12 1085 DY76C 9T11C1005G63
150 (+2, -4 2.5%) 12 1610 DY77C 9T11C1006G63
225 (+2, -2 2.5%) 12 3720 DX79C 9T11C1007G63
300 (+2, -4 2.5%) 12 2 2 9T11C1008G63
1See page 10-45 for wiring diagrams.
2Call GE Technical Support at 1-800-GE 1-STOP, Option #4

Rev. 11/13 www.geindustrial.com BuyLogTM Catalog 10-17


Data subject to change
without notice
Dry Type Transformers Section 10
K-Factor
Copper
Three-Phase DOE 2016 Efficiency

K=20 150C Rise NEMA 2


Input Output Wiring Approx. Net Frame Product
Voltage Voltage kVA Taps Diagram No.1 Weight (Lbs) Size Number
15 (+2, -4 2.5%) 12 2 2 9T12C1001G03
30 (+2, -4 2.5%) 12 2 2 9T12C1002G03
45 (+2, -4 2.5%) 12 2 2 9T12C1003G03
75 (+2, -4 2.5%) 12 2 2 9T12C1004G03
480 Volts Delta 208Y/120 Volts
112.5 (+2, -4 2.5%) 12 2 2 9T12C1005G03
150 (+2, -4 2.5%) 12 2 2 9T12C1006G03
225 (+2, -4 2.5%) 12 2 2 9T12C1007G03
300 (+2, -4 2.5%) 12 2 2 9T12C1008G03

K=20 115C Rise NEMA 2


Input Output Wiring Approx. Net Frame Product
Voltage Voltage kVA Taps Diagram No.1 Weight (Lbs) Size Number
15 (+2, -4 2.5%) 12 2 2 9T12C1001G33
30 (+2, -4 2.5%) 12 2 2 9T12C1002G33
45 (+2, -4 2.5%) 12 2 2 9T12C1003G33
75 (+2, -4 2.5%) 12 2 2 9T12C1004G33
480 Volts Delta 208Y/120 Volts
112.5 (+2, -4 2.5%) 12 2 2 9T12C1005G33
150 (+2, -4 2.5%) 12 2 2 9T12C1006G33
225 (+2, -4 2.5%) 12 2 2 9T12C1007G33
300 (+2, -4 2.5%) 12 2 2 9T12C1008G33

K=20 80C Rise NEMA 2


Input Output Wiring Approx. Net Frame Product
Voltage Voltage kVA Taps Diagram No.1 Weight (Lbs) Size Number
15 (+2, -4 2.5%) 12 2 2 9T12C1001G63
30 (+2, -4 2.5%) 12 2 2 9T12C1002G63
45 (+2, -4 2.5%) 12 2 2 9T12C1003G63
480 Volts Delta 208Y/120 Volts
75 (+2, -4 2.5%) 12 2 2 9T12C1004G63
112.5 (+2, -4 2.5%) 12 2 2 9T12C1005G63
150 (+2, -4 2.5%) 12 2 2 9T12C1006G63
1See page 10-45 for wiring diagrams.
2Call GE Technical Support at 1-800-GE 1-STOP, Option #4

10-18 BuyLogTM Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Dry Type Transformers Section 10
K-Factor
Copper
Three-Phase DOE 2016 Efficiency

K=30 150C Rise NEMA 2


Input Output Wiring Approx. Net Frame Product
Voltage Voltage kVA Taps Diagram No.1 Weight (Lbs) Size Number
15 (+2, -4 2.5%) 12 2 2 9T13C1001G03
30 (+2, -4 2.5%) 12 2 2 9T13C1002G03
45 (+2, -4 2.5%) 12 2 2 9T13C1003G03
480 Volts Delta 208Y/120 Volts 75 (+2, -4 2.5%) 12 2 2 9T13C1004G03
112.5 (+2, -4 2.5%) 12 2 2 9T13C1005G03
150 (+2, -4 2.5%) 12 2 2 9T13C1006G03
225 (+2, -4 2.5%) 12 2 2 9T13C1007G03

K=30 115C Rise NEMA 2


Input Output Wiring Approx. Net Frame Product
Voltage Voltage kVA Taps Diagram No.1 Weight (Lbs) Size Number
15 (+2, -4 2.5%) 12 2 2 9T13C1001G33
30 (+2, -4 2.5%) 12 2 2 9T13C1002G33
45 (+2, -4 2.5%) 12 2 2 9T13C1003G33
480 Volts Delta 208Y/120 Volts 75 (+2, -4 2.5%) 12 2 2 9T13C1004G33
112.5 (+2, -4 2.5%) 12 2 2 9T13C1005G33
150 (+2, -4 2.5%) 12 2 2 9T13C1006G33
225 (+2, -4 2.5%) 12 2 2 9T13C1007G33

K=30 80C Rise NEMA 2


Input Output Wiring Approx. Net Frame Product
Voltage Voltage kVA Taps Diagram No.1 Weight (Lbs) Size Number
15 (+2, -4 2.5%) 12 2 2 9T13C1001G63
30 (+2, -4 2.5%) 12 2 2 9T13C1002G63
480 Volts Delta 208Y/120 Volts 45 (+2, -4 2.5%) 12 2 2 9T13C1003G63
75 (+2, -4 2.5%) 12 2 2 9T13C1004G63
150 (+2, -4 2.5%) 12 2 2 9T13C1006G63
1See page 10-45 for wiring diagrams.
2Call GE Technical Support at 1-800-GE 1-STOP, Option #4

Rev. 11/13 www.geindustrial.com BuyLogTM Catalog 10-19


Data subject to change
without notice
Page Updated 09 / 2016

Dry Type Transformers Section 10


K-Factor Low Noise (-3dB below NEMA ST-20 Standard)
Aluminum
Three-Phase DOE 2016 Efficiency

K=4 150C Rise


Input Output Wiring Approx. Net Frame Product
Voltage Voltage kVA Taps Diagram No.1 Weight (Lbs) Size Number
15 (+2, -4 2.5%) 12 231 UX71A 9T14A1001G04
30 (+2, -4 2.5%) 12 444 UX73A 9T14A1002G04
45 (+2, -4 2.5%) 12 444 UX73A 9T14A1003G04
75 (+2, -4 2.5%) 12 603 UX74A 9T14A1004G04
480 Volts Delta 208Y/120 Volts
112.5 (+2, -4 2.5%) 12 1030 DY76A 9T14A1005G04
150 (+2, -4 2.5%) 12 1250 DX76A 9T14A1006G04
225 (+2, -4 2.5%) 12 1670 DY78A 9T14A1007G04
300 (+2, -2 2.5%) 12 2900 DX79A 9T14A1008G04

K=4 115C Rise


Input Output Wiring Approx. Net Frame Product
Voltage Voltage kVA Taps Diagram No.1 Weight (Lbs) Size Number
15 (+2, -4 2.5%) 12 231 UX71A 9T14A1001G34
30 (+2, -4 2.5%) 12 444 UX73A 9T14A1002G34
45 (+2, -4 2.5%) 12 561 UY74A 9T14A1003G34
75 (+2, -4 2.5%) 12 680 DY75A 9T14A1004G34
480 Volts Delta 208Y/120 Volts
112.5 (+2, -4 2.5%) 12 1030 DY76A 9T14A1005G34
150 (+2, -4 2.5%) 12 1250 DX76A 9T14A1006G34
225 (+2, -4 2.5%) 12 1670 DY78A 9T14A1007G34
300 (+2, -2 2.5%) 12 2900 DX79A 9T14A1008G34

K=4 80C Rise


Input Output Wiring Approx. Net Frame Product
Voltage Voltage kVA Taps Diagram No.1 Weight (Lbs) Size Number
15 (+2, -4 2.5%) 12 330 UX72A 9T14A1001G64
30 (+2, -4 2.5%) 12 444 UX73A 9T14A1002G64
45 (+2, -4 2.5%) 12 561 UY74A 9T14A1003G64
480 Volts Delta 208Y/120 Volts 75 (+2, -4 2.5%) 12 830 DX75A 9T14A1004G64
112.5 (+2, -4 2.5%) 12 1250 DX76A 9T14A1005G62
150 (+2, -4 2.5%) 12 1670 DX77A 9T14A1006G62
225 (+2, -4 2.5%) 12 1670 DY78A 9T14A1007G64
300 (+2, -2 2.5%) 12 2900 DX79A 9T14A1008G64

K=13 150C Rise


Input Output Wiring Approx. Net Frame Product
Voltage Voltage kVA Taps Diagram No.1 Weight (Lbs) Size Number
15 (+2, -4 2.5%) 12 231 UX71A 9T11A1001G04
30 (+2, -4 2.5%) 12 444 UX73A 9T11A1002G04
45 (+2, -4 2.5%) 12 444 UX73A 9T11A1003G04
75 (+2, -4 2.5%) 12 603 UX74A 9T11A1004G04
480 Volts Delta 208Y/120 Volts
112.5 (+2, -4 2.5%) 12 1030 DY76A 9T11A1005G04
150 (+2, -4 2.5%) 12 1250 DX76A 9T11A1006G04
225 (+2, -4 2.5%) 12 1670 DY78A 9T11A1007G04
300 (+2, -2 2.5%) 12 2900 DX79A 9T11A1008G04

K=13 115C Rise


Input Output Wiring Approx. Net Frame Product
Voltage Voltage kVA Taps Diagram No.1 Weight (Lbs) Size Number
15 (+2, -4 2.5%) 12 231 UX71A 9T11A1001G34
30 (+2, -4 2.5%) 12 444 UX73A 9T11A1002G34
45 (+2, -4 2.5%) 12 561 UY74A 9T11A1003G34
75 (+2, -4 2.5%) 12 680 DY75A 9T11A1004G34
480 Volts Delta 208Y/120 Volts
112.5 (+2, -4 2.5%) 12 1250 DX76A 9T11A1005G34
150 (+2, -4 2.5%) 12 1450 DY77A 9T11A1006G34
225 (+2, -4 2.5%) 12 1670 DY78A 9T11A1007G34
300 (+2, -2 2.5%) 12 2900 DX79A 9T11A1008G34

K=13 80C Rise


Input Output Wiring Approx. Net Frame Product
Voltage Voltage kVA Taps Diagram No.1 Weight (Lbs) Size Number
15 (+2, -4 2.5%) 12 330 UX72A 9T11A1001G64
30 (+2, -4 2.5%) 12 561 UY74A 9T11A1002G64
45 (+2, -4 2.5%) 12 561 UY74A 9T11A1003G64
480 Volts Delta 208Y/120 Volts
75 (+2, -4 2.5%) 12 680 DY75A 9T11A1004G64
112.5 (+2, -4 2.5%) 12 1670 DX77A 9T11A1005G64
150 (+2, -4 2.5%) 12 1670 DY78A 9T11A1006G64
1See page 10-45 for wiring diagrams.

10-20 BuyLogTM Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Dry Type Transformers Section 10
K-Factor Low Noise (-3 dB below NEMA ST-20 Standard)
Aluminum
Three-Phase DOE 2016 Efficiency

K=20 150C Rise


Input Output Wiring Approx. Net Frame Product
Voltage Voltage kVA Taps Diagram No.1 Weight (Lbs) Size Number
15 (+2, -4 2.5%) 12 2 2 9T12A1001G04
30 (+2, -4 2.5%) 12 2 2 9T12A1002G04
45 (+2, -4 2.5%) 12 2 2 9T12A1003G04
480 Volts Delta 208Y/120 Volts 75 (+2, -4 2.5%) 12 2 2 9T12A1004G04
112.5 (+2, -4 2.5%) 12 2 2 9T12A1005G04
150 (+2, -4 2.5%) 12 2 2 9T12A1006G04
225 (+2, -4 2.5%) 12 2 2 9T12A1007G04

K=20 115C Rise


Input Output Wiring Approx. Net Frame Product
Voltage Voltage kVA Taps Diagram No.1 Weight (Lbs) Size Number
15 (+2, -4 2.5%) 12 2 2 9T12A1001G34
30 (+2, -4 2.5%) 12 2 2 9T12A1002G34
480 Volts Delta 208Y/120 Volts 2 2
45 (+2, -4 2.5%) 12 9T12A1003G34
75 (+2, -4 2.5%) 12 2 2 9T12A1004G34
112.5 (+2, -4 2.5%) 12 2 2 9T12A1005G34

K=20 80C Rise


Input Output Wiring Approx. Net Frame Product
Voltage Voltage kVA Taps Diagram No.1 Weight (Lbs) Size Number
15 (+2, -4 2.5%) 12 2 2 9T12A1001G64
30 (+2, -4 2.5%) 12 2 2 9T12A1002G64
480 Volts Delta 208Y/120 Volts 2 2
45 (+2, -4 2.5%) 12 9T12A1003G64
75 (+2, -4 2.5%) 12 2 2 9T12A1004G64
112.5 (+2, -4 2.5%) 12 2 2 9T12A1005G64

K=30 150C Rise


Input Output Wiring Approx. Net Frame Product
Voltage Voltage kVA Taps Diagram No.1 Weight (Lbs) Size Number
15 (+2, -4 2.5%) 12 2 2 9T13A1001G04
30 (+2, -4 2.5%) 12 2 2 9T13A1002G04
45 (+2, -4 2.5%) 12 2 2 9T13A1003G04
480 Volts Delta 208Y/120 Volts
75 (+2, -4 2.5%) 12 2 2 9T13A1004G04
112.5 (+2, -4 2.5%) 12 2 2 9T13A1005G04
150 (+2, -4 2.5%) 12 2 2 9T13A1006G04

K=30 115C Rise


Input Output Wiring Approx. Net Frame Product
Voltage Voltage kVA Taps Diagram No.1 Weight (Lbs) Size Number
15 (+2, -4 2.5%) 12 2 2 9T13A1001G34
30 (+2, -4 2.5%) 12 2 2 9T13A1002G34
480 Volts Delta 208Y/120 Volts 2 2
45 (+2, -4 2.5%) 12 9T13A1003G34
75 (+2, -4 2.5%) 12 2 2 9T13A1004G34
112.5 (+2, -4 2.5%) 12 2 2 9T13A1005G34
1See page 10-45 for wiring diagrams.
2Call GE Technical Support at 1-800-GE 1-STOP, Option #4

Rev. 11/13 www.geindustrial.com BuyLogTM Catalog 10-21


Data subject to change
without notice
Dry Type Transformers Section 10
K-Factor Low Noise (-3 dB below NEMA ST-20 Standard)
Copper
Three-Phase DOE 2016 Efficiency

K = 4 150C Rise
Input Output Wiring Approx. Net Frame Product
Voltage Voltage kVA Taps Diagram No.1 Weight (Lbs) Size Number
15 (+2, -4 2.5%) 12 230 UX71C 9T14C1001G04
30 (+2, -4 2.5%) 12 353 UX72C 9T14C1002G04
45 (+2, -4 2.5%) 12 480 UX73C 9T14C1003G04
75 (+2, -4 2.5%) 12 661 UY74C 9T14C1004G04
480 Volts Delta 208Y/120 Volts
112.5 (+2, -4 2.5%) 12 790 DY75C 9T14C1005G04
150 (+2, -4 2.5%) 12 1610 DY77C 9T14C1006G04
225 (+2, -4 2.5%) 12 1970 DY78C 9T14C1007G04
300 (+2, -2 2.5%) 12 3720 DX79C 9T14C1008G04

K = 4 115C Rise
Input Output Wiring Approx. Net Frame Product
Voltage Voltage kVA Taps Diagram No.1 Weight (Lbs) Size Number
15 (+2, -4 2.5%) 12 353 UX72C 9T14C1001G34
30 (+2, -4 2.5%) 12 353 UX72C 9T14C1002G34
45 (+2, -4 2.5%) 12 661 UY74C 9T14C1003G34
480 Volts Delta 208Y/120 Volts 75 (+2, -4 2.5%) 12 790 DY75C 9T14C1004G34
112.5 (+2, -4 2.5%) 12 900 DX75C 9T14C1005G34
150 (+2, -4 2.5%) 12 1610 DY77C 9T14C1006G34
225 (+2, -4 2.5%) 12 2150 DX78C 9T14C1007G34
300 (+2, -2 2.5%) 12 3720 DX79C 9T14C1008G34

K = 4 80C Rise
Input Output Wiring Approx. Net Frame Product
Voltage Voltage kVA Taps Diagram No.1 Weight (Lbs) Size Number
15 (+2, -4 2.5%) 12 353 UX72C 9T14C1001G64
30 (+2, -4 2.5%) 12 480 UX73C 9T14C1002G64
45 (+2, -4 2.5%) 12 661 UY74C 9T14C1003G64
480 Volts Delta 208Y/120 Volts 75 (+2, -4 2.5%) 12 790 DY75C 9T14C1004G64
112.5 (+2, -4 2.5%) 12 1240 DX76C 9T14C1005G64
150 (+2, -4 2.5%) 12 1610 DY77C 9T14C1006G64
225 (+2, -2 2.5%) 12 3720 DX79C 9T14C1007G64

K = 13 150C Rise
Input Output Wiring Approx. Net Frame Product
Voltage Voltage kVA Taps Diagram No.1 Weight (Lbs) Size Number
15 (+2, -4 2.5%) 12 230 UX71C 9T11C1001G04
30 (+2, -4 2.5%) 12 353 UX72C 9T11C1002G04
45 (+2, -4 2.5%) 12 480 UX73C 9T11C1003G04
480 Volts Delta 208Y/120 Volts 75 (+2, -4 2.5%) 12 790 DY75C 9T11C1004G04
112.5 (+2, -4 2.5%) 12 790 DY75C 9T11C1005G04
150 (+2, -4 2.5%) 12 1610 DY77C 9T11C1006G04
225 (+2, -4 2.5%) 12 1970 DY78C 9T11C1007G04
300 (+2, -2 2.5%) 12 3720 DX79C 9T11C1008G04

K = 13 115C Rise
Input Output Wiring Approx. Net Frame Product
Voltage Voltage kVA Taps Diagram No.1 Weight (Lbs) Size Number
15 (+2, -4 2.5%) 12 353 UX72C 9T11C1001G34
30 (+2, -4 2.5%) 12 480 UX73C 9T11C1002G34
45 (+2, -4 2.5%) 12 661 UY74C 9T11C1003G34
480 Volts Delta 208Y/120 Volts 75 (+2, -4 2.5%) 12 790 DY75C 9T11C1004G34
112.5 (+2, -4 2.5%) 12 1085 DY76C 9T11C1005G34
150 (+2, -4 2.5%) 12 1610 DY77C 9T11C1006G34
225 (+2, -2 2.5%) 12 3720 DX79C 9T11C1007G34
300 (+2, -2 2.5%) 12 3720 DX79C 9T11C1008G34

K = 13 80C Rise
Input Output Wiring Approx. Net Frame Product
Voltage Voltage kVA Taps Diagram No.1 Weight (Lbs) Size Number
15 (+2, -4 2.5%) 12 353 UX72C 9T11C1001G64
30 (+2, -4 2.5%) 12 661 UY74C 9T11C1002G64
45 (+2, -4 2.5%) 12 661 UY74C 9T11C1003G64
480 Volts Delta 208Y/120 Volts 75 (+2, -4 2.5%) 12 790 DY75C 9T11C1004G64
112.5 (+2, -4 2.5%) 12 1240 DX76C 9T11C1005G64
150 (+2, -4 2.5%) 12 1610 DY77C 9T11C1006G64
225 (+2, -2 2.5%) 12 3720 DX79C 9T11C1007G64
1See page 10-45 for wiring diagrams.

10-22 BuyLogTM Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Dry Type Transformers Section 10
K-Factor Low Noise (-3 dB below NEMA ST-20 Standard)
Copper
Three-Phase DOE 2016 Efficiency

K = 20 150C Rise
Input Output Wiring Approx. Net Frame Product
Voltage Voltage kVA Taps Diagram No.1 Weight (Lbs) Size Number
15 (+2, -4 2.5%) 12 2 2 9T12C1001G04
30 (+2, -4 2.5%) 12 2 2 9T12C1002G04
45 (+2, -4 2.5%) 12 2 2 9T12C1003G04
480 Volts Delta 208Y/120 Volts
75 (+2, -4 2.5%) 12 2 2 9T12C1004G04
112.5 (+2, -4 2.5%) 12 2 2 9T12C1005G04
150 (+2, -4 2.5%) 12 2 2 9T12C1006G04

K = 20 115C Rise
Input Output Wiring Approx. Net Frame Product
Voltage Voltage kVA Taps Diagram No.1 Weight (Lbs) Size Number
15 (+2, -4 2.5%) 12 2 2 9T12C1001G34
30 (+2, -4 2.5%) 12 2 2 9T12C1002G34
45 (+2, -4 2.5%) 12 2 2 9T12C1003G34
480 Volts Delta 208Y/120 Volts 2 2
75 (+2, -4 2.5%) 12 9T12C1004G34
112.5 (+2, -4 2.5%) 12 2 2 9T12C1005G34
150 (+2, -4 2.5%) 12 2 2 9T12C1006G34

K = 20 80C Rise
Input Output Wiring Approx. Net Frame Product
Voltage Voltage kVA Taps Diagram No.1 Weight (Lbs) Size Number
15 (+2, -4 2.5%) 12 2 2 9T12C1001G64
30 (+2, -4 2.5%) 12 2 2 9T12C1002G64
480 Volts Delta 208Y/120 Volts 2 2
45 (+2, -4 2.5%) 12 9T12C1003G64
75 (+2, -4 2.5%) 12 2 2 9T12C1004G64
112.5 (+2, -4 2.5%) 12 2 2 9T12C1005G64

K = 30 150C Rise
Input Output Wiring Approx. Net Frame Product
Voltage Voltage kVA Taps Diagram No.1 Weight (Lbs) Size Number
15 (+2, -4 2.5%) 12 2 2 9T13C1001G04
30 (+2, -4 2.5%) 12 2 2 9T13C1002G04
45 (+2, -4 2.5%) 12 2 2 9T13C1003G04
480 Volts Delta 208Y/120 Volts
75 (+2, -4 2.5%) 12 2 2 9T13C1004G04
112.5 (+2, -4 2.5%) 12 2 2 9T13C1005G04
150 (+2, -4 2.5%) 12 2 2 9T13C1006G04

K = 30 115C Rise
Input Output Wiring Approx. Net Frame Product
Voltage Voltage kVA Taps Diagram No.1 Weight (Lbs) Size Number
15 (+2, -4 2.5%) 12 2 2 9T13C1001G34
30 (+2, -4 2.5%) 12 2 2 9T13C1002G34
480 Volts Delta 208Y/120 Volts 45 (+2, -4 2.5%) 12 2 2 9T13C1003G34
75 (+2, -4 2.5%) 12 2 2 9T13C1004G34
112.5 (+2, -4 2.5%) 12 2 2 9T13C1005G34
1See page 10-45 for wiring diagrams.
2Call GE Technical Support at 1-800-GE 1-STOP, Option #4

Rev. 11/13 www.geindustrial.com BuyLogTM Catalog 10-23


Data subject to change
without notice
Dry Type Transformers Section 10
Low Noise (-3 dB below NEMA ST-20 Standard)
Aluminum
Three-Phase DOE 2016 Efficiency

Product Description
These low noise transformers are designed to operate at reduced
noise levels. The vibrations within the magnetic steel core have
been greatly reduced, thus lowering the humming of the trans-
former 3 dB less than NEMA/ANSI standards. Available in
Aluminum or Copper windings, with either a 150C, 115C or
80C rise.

Application
Type QL low noise transformers are ideal when quiet operation is
required such as near offices, in school buildings, or hospitals.
Although they are inherently quieter, installation can greatly
influence their noise level and therefore care should be taken in
following acoustical principles as well as proper installation
procedures. Closets and corners should be avoided as they act as
megaphones by seemingly increasing noise levels. Type QL Low Noise Transformer (front panel removed)

150C Rise NEMA 2


Input Output Wiring Approx Net Frame Product
Voltage Voltage kVA Taps Diagram No.1 Weight (Lbs) Size Number
15 (+2, -4 2.5%) 12 231 UX71A 9T10A1001G02
30 (+2, -4 2.5%) 12 330 UX72A 9T10A1002G02
45 (+2, -4 2.5%) 12 444 UX73A 9T10A1003G02
75 (+2, -4 2.5%) 12 561 UY74A 9T10A1004G02
480 Volts Delta 208Y/120 Volts 112.5 (+2, -4 2.5%) 12 680 DY75A 9T10A1005G02
150 (+2, -4 2.5%) 12 1030 DY76A 9T10A1006G02
225 (+2, -4 2.5%) 12 1450 DY77A 9T10A1007G02
300 (+2, -4 2.5%) 12 1670 DY78A 9T10A1008G02
500 (+2, -2 2.5%) 12 2900 DX79A 9T10A1009G02

115C Rise NEMA 2


Input Output Wiring Approx Net Frame Product
Voltage Voltage kVA Taps Diagram No.1 Weight (Lbs) Size Number
15 (+2, -4 2.5%) 12 231 UX71A 9T10A1001G32
30 (+2, -4 2.5%) 12 330 UX72A 9T10A1002G32
45 (+2, -4 2.5%) 12 444 UX73A 9T10A1003G32
75 (+2, -4 2.5%) 12 603 UX74A 9T10A1004G32
480 Volts Delta 208Y/120 Volts 112.5 (+2, -4 2.5%) 12 830 DX75A 9T10A1005G32
150 (+2, -4 2.5%) 12 1250 DX76A 9T10A1006G32
225 (+2, -4 2.5%) 12 1670 DX77A 9T10A1007G32
300 (+2, -4 2.5%) 12 1985 DX78A 9T10A1008G32
500 (+2, -2 2.5%) 12 2900 DX79A 9T10A1009G32

80C Rise NEMA 2


Input Output Wiring Approx Net Frame Product
Voltage Voltage kVA Taps Diagram No.1 Weight (Lbs) Size Number
15 (+2, -4 2.5%) 12 330 UX72A 9T10A1001G62
30 (+2, -4 2.5%) 12 444 UX73A 9T10A1002G62
45 (+2, -4 2.5%) 12 561 UY74A 9T10A1003G62
480 Volts Delta 208Y/120 Volts 75 (+2, -4 2.5%) 12 680 DY75A 9T10A1004G62
112.5 (+2, -4 2.5%) 12 1030 DY76A 9T10A1005G62
150 (+2, -4 2.5%) 12 1450 DY77A 9T10A1006G62
225 (+2, -4 2.5%) 12 1985 DX78A 9T10A1007G62
300 (+2, -2 2.5%) 12 2900 DX79A 9T10A1008G62
1See page 10-45 for wiring diagrams.
2Call GE Technical Support at 1-800-GE 1-STOP, Option #4

10-24 BuyLogTM Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Dry Type Transformers Section 10
Low Noise (-3 dB below NEMA ST-20 Standard)
Copper
Three-Phase DOE 2016 Efficiency

150C Rise NEMA 2


Input Output Wiring Approx Net Frame Product
Voltage Voltage kVA Taps Diagram No.1 Weight (Lbs) Size Number
15 (+2, -4 2.5%) 12 230 UX71C 9T10C1001G02
30 (+2, -4 2.5%) 12 353 UX72C 9T10C1002G02
45 (+2, -4 2.5%) 12 480 UX73C 9T10C1003G02
75 (+2, -4 2.5%) 12 661 UY74C 9T10C1004G02
480 Volts Delta 208Y/120 Volts 112.5 (+2, -4 2.5%) 12 790 DY75C 9T10C1005G02
150 (+2, -4 2.5%) 12 1085 DY76C 9T10C1006G02
225 (+2, -4 2.5%) 12 1610 DY77C 9T10C1007G02
300 (+2, -4 2.5%) 12 1970 DY78C 9T10C1008G02
500 (+2, -2 2.5%) 12 3720 DX79C 9T10C1009G02

115C Rise NEMA 2


Input Output Wiring Approx Net Frame Product
Voltage Voltage kVA Taps Diagram No.1 Weight (Lbs) Size Number
15 (+2, -4 2.5%) 12 230 UX71C 9T10C1001G32
30 (+2, -4 2.5%) 12 353 UX72C 9T10C1002G32
45 (+2, -4 2.5%) 12 480 UX73C 9T10C1003G32
75 (+2, -4 2.5%) 12 748 UX74C 9T10C1004G32
480 Volts Delta 208Y/120 Volts 112.5 (+2, -4 2.5%) 12 900 DX75C 9T10C1005G32
150 (+2, -4 2.5%) 12 1240 DX76C 9T10C1006G32
225 (+2, -4 2.5%) 12 1847 DX77C 9T10C1007G32
300 (+2, -4 2.5%) 12 2150 DX78C 9T10C1008G32
500 (+2, -2 2.5%) 12 3720 DX79C 9T10C1009G32

80C Rise NEMA 2


Input Output Wiring Approx Net Frame Product
Voltage Voltage kVA Taps Diagram No.1 Weight (Lbs) Size Number
15 (+2, -4 2.5%) 12 353 UX72C 9T10C1001G62
30 (+2, -4 2.5%) 12 480 UX73C 9T10C1002G62
45 (+2, -4 2.5%) 12 661 UY74C 9T10C1003G62
75 (+2, -4 2.5%) 12 790 DY75C 9T10C1004G62
480 Volts Delta 208Y/120 Volts
112.5 (+2, -4 2.5%) 12 1085 DY76C 9T10C1005G62
150 (+2, -4 2.5%) 12 1610 DY77C 9T10C1006G62
225 (+2, -4 2.5%) 12 2150 DX78C 9T10C1007G62
300 (+2, -2 2.5%) 12 3720 DX79C 9T10C1008G62
1See page 10-45 for wiring diagrams.

Rev. 11/13 www.geindustrial.com BuyLogTM Catalog 10-25


Data subject to change
without notice
Dry Type Transformers Section 10
Noise Isolation Guard I (Electrostatic Shield)
Aluminum
Three-Phase DOE 2016 Efficiency

150C Rise NEMA 2


Input Output Wiring Approx Net Frame Product
Voltage Voltage kVA Taps Diagram No.1 Weight (Lbs) Size Number
15 (+2, -4 2.5%) 12 231 UX71A 9T10A1001G03
30 (+2, -4 2.5%) 12 330 UX72A 9T10A1002G03
45 (+2, -4 2.5%) 12 444 UX73A 9T10A1003G03
75 (+2, -4 2.5%) 12 561 UY74A 9T10A1004G03
480 Volts Delta 208Y/120 Volts 112.5 (+2, -4 2.5%) 12 680 DY75A 9T10A1005G03
150 (+2, -4 2.5%) 12 1030 DY76A 9T10A1006G03
225 (+2, -4 2.5%) 12 1450 DY77A 9T10A1007G03
300 (+2, -4 2.5%) 12 1670 DY78A 9T10A1008G03
500 (+2, -2 2.5%) 12 2900 DX79A 9T10A1009G03

115C Rise NEMA 2


Input Output Wiring Approx Net Frame Product
Voltage Voltage kVA Taps Diagram No.1 Weight (Lbs) Size Number
15 (+2, -4 2.5%) 12 231 UX71A 9T10A1001G33
30 (+2, -4 2.5%) 12 330 UX72A 9T10A1002G33
45 (+2, -4 2.5%) 12 444 UX73A 9T10A1003G33
75 (+2, -4 2.5%) 12 603 UX74A 9T10A1004G33
480 Volts Delta 208Y/120 Volts 112.5 (+2, -4 2.5%) 12 830 DX75A 9T10A1005G33
150 (+2, -4 2.5%) 12 1250 DX76A 9T10A1006G33
225 (+2, -4 2.5%) 12 1670 DX77A 9T10A1007G33
300 (+2, -4 2.5%) 12 1985 DX78A 9T10A1008G33
500 (+2, -2 2.5%) 12 2900 DX79A 9T10A1009G33

80C Rise NEMA 2


Input Output Wiring Approx Net Frame Product
Voltage Voltage kVA Taps Diagram No.1 Weight (Lbs) Size Number
15 (+2, -4 2.5%) 12 330 UX72A 9T10A1001G63
30 (+2, -4 2.5%) 12 444 UX73A 9T10A1002G63
45 (+2, -4 2.5%) 12 561 UY74A 9T10A1003G63
75 (+2, -4 2.5%) 12 680 DY75A 9T10A1004G63
480 Volts Delta 208Y/120 Volts
112.5 (+2, -4 2.5%) 12 1030 DY76A 9T10A1005G63
150 (+2, -4 2.5%) 12 1450 DY77A 9T10A1006G63
225 (+2, -4 2.5%) 12 1985 DX78A 9T10A1007G63
300 (+2, -2 2.5%) 12 2900 DX79A 9T10A1008G63
1See page 10-45 for wiring diagrams.

10-26 BuyLogTM Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Dry Type Transformers Section 10
Noise Isolation Guard I (Electrostatic Shield)
Copper
Three-Phase DOE 2016 Efficiency

150C Rise NEMA 2


Input Output Wiring Approx Net Frame Product
Voltage Voltage kVA Taps Diagram No.1 Weight (Lbs) Size Number
15 (+2, -4 2.5%) 12 230 UX71C 9T10C1001G03
30 (+2, -4 2.5%) 12 353 UX72C 9T10C1002G03
45 (+2, -4 2.5%) 12 480 UX73C 9T10C1003G03
75 (+2, -4 2.5%) 12 661 UY74C 9T10C1004G03
480 Volts Delta 208Y/120 Volts 112.5 (+2, -4 2.5%) 12 790 DY75C 9T10C1005G03
150 (+2, -4 2.5%) 12 1085 DY76C 9T10C1006G03
225 (+2, -4 2.5%) 12 1610 DY77C 9T10C1007G03
300 (+2, -4 2.5%) 12 1970 DY78C 9T10C1008G03
500 (+2, -2 2.5%) 12 3720 DX79C 9T10C1009G03

115C Rise NEMA 2


Input Output Wiring Approx Net Frame Product
Voltage Voltage kVA Taps Diagram No.1 Weight (Lbs) Size Number
15 (+2, -4 2.5%) 12 230 UX71C 9T10C1001G33
30 (+2, -4 2.5%) 12 353 UX72C 9T10C1002G33
45 (+2, -4 2.5%) 12 480 UX73C 9T10C1003G33
75 (+2, -4 2.5%) 12 748 UX74C 9T10C1004G33
480 Volts Delta 208Y/120 Volts 112.5 (+2, -4 2.5%) 12 900 DX75C 9T10C1005G33
150 (+2, -4 2.5%) 12 1240 DX76C 9T10C1006G33
225 (+2, -4 2.5%) 12 1847 DX77C 9T10C1007G33
300 (+2, -4 2.5%) 12 2150 DX78C 9T10C1008G33
500 (+2, -2 2.5%) 12 3720 DX79C 9T10C1009G33

80C Rise NEMA 2


Input Output Wiring Approx Net Frame Product
Voltage Voltage kVA Taps Diagram No.1 Weight (Lbs) Size Number
15 (+2, -4 2.5%) 12 353 UX72C 9T10C1001G63
30 (+2, -4 2.5%) 12 480 UX73C 9T10C1002G63
45 (+2, -4 2.5%) 12 661 UY74C 9T10C1003G63
75 (+2, -4 2.5%) 12 790 DY75C 9T10C1004G63
480 Volts Delta 208Y/120 Volts
112.5 (+2, -4 2.5%) 12 1085 DY76C 9T10C1005G63
150 (+2, -4 2.5%) 12 1610 DY77C 9T10C1006G63
225 (+2, -4 2.5%) 12 2150 DX78C 9T10C1007G63
300 (+2, -2 2.5%) 12 3720 DX79C 9T10C1008G63
1See page 10-45 for wiring diagrams.

Rev. 11/13 www.geindustrial.com BuyLogTM Catalog 10-27


Data subject to change
without notice
Dry Type Transformers Section 10
Noise Isolation Guard II

Guard II noise isolation transformers provide common mode


noise attenuation plus an enhanced level of transverse mode
noise attenuation for increased protection of sensitive electronic
equipment.

Key Features
Grounded copper electrostatic shield between
primary and secondary windings
Noise suppressors and spike/surge suppressors
120dB common mode noise rejection
60dB transverse mode noise rejection
Compliance with ANSI and NEMA standards
Sound levels below NEMA ST-20 limits
UL Listed Guard II Transformer
NEMA 2 enclosure

Applications
Schools and colleges
Large computer installations
Small commercial offices
Motor installations
Process controllers
Hospitals
X-ray rooms
Electrical laboratories
High lightning strike areas

Guard II Transformer, (front panel removed)

10-28 BuyLogTM Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Page Updated 09 / 2016

Dry Type Transformers Section 10


Noise Isolation Guard II
Aluminum
Three-Phase DOE 2016 Efficiency

150C Rise
Input Output Wiring Approx Net Frame Product
Voltage Voltage kVA Taps Diagram No.1 Weight (Lbs) Size Number
15 (+2, -4 2.5%) 12 260 XV371 9T17A1001G03
30 (+2, -4 2.5%) 12 370 XV372 9T17A1002G03
480 Volts Delta 208Y/120 Volts 45 (+2, -4 2.5%) 12 460 XV373 9T17A1003G03
75 (+2, -4 2.5%) 12 680 XV374 9T17A1004G03
112.5 (+2, -4 2.5%) 12 830 XV375 9T17A1005G03

115C Rise
Input Output Wiring Approx Net Frame Product
Voltage Voltage kVA Taps Diagram No.1 Weight (Lbs) Size Number
15 (+2, -4 2.5%) 12 260 XV371 9T17A1001G33
30 (+2, -4 2.5%) 12 370 XV372 9T17A1002G33
480 Volts Delta 208Y/120 Volts
45 (+2, -4 2.5%) 12 460 XV373 9T17A1003G33
75 (+2, -4 2.5%) 12 680 XV374 9T17A1004G33

80C Rise
Input Output Wiring Approx Net Frame Product
Voltage Voltage kVA Taps Diagram No.1 Weight (Lbs) Size Number
15 (+2, -4 2.5%) 12 370 XV372 9T17A1001G63
30 (+2, -4 2.5%) 12 460 XV373 9T17A1002G63
480 Volts Delta 208Y/120 Volts
45 (+2, -4 2.5%) 12 680 XV374 9T17A1003G63
75 (+2, -4 2.5%) 12 830 XV375 9T17A1004G63

150C Rise
Input Output Wiring Approx Net Frame Product
Voltage Voltage kVA Taps Diagram No.1 Weight (Lbs) Size Number
15 (+2, -4 2.5%) 12 260 XV371 9T17A1451G03
30 (+2, -4 2.5%) 12 370 XV372 9T17A1452G03
208 Volts Delta 208Y/120 Volts 45 (+2, -4 2.5%) 12 460 XV373 9T17A1453G03
75 (+2, -4 2.5%) 12 680 XV374 9T17A1454G03
112.5 (+2, -4 2.5%) 12 830 XV375 9T17A1455G03

115C Rise
Input Output Wiring Approx Net Frame Product
Voltage Voltage kVA Taps Diagram No.1 Weight (Lbs) Size Number
15 (+2, -4 2.5%) 12 260 XV371 9T17A1451G33
208 Volts Delta 208Y/120 Volts 30 (+2, -4 2.5%) 12 370 XV372 9T17A1452G33
45 (+2, -4 2.5%) 12 460 XV373 9T17A1453G33
75 (+2, -4 2.5%) 12 680 XV374 9T17A1454G33

80C Rise
Input Output Wiring Approx Net Frame Product
Voltage Voltage kVA Taps Diagram No.1 Weight (Lbs) Size Number
15 (+2, -4 2.5%) 12 370 XV372 9T17A1451G63
30 (+2, -4 2.5%) 12 460 XV373 9T17A1452G63
208 Volts Delta 208Y/120 Volts
45 (+2, -4 2.5%) 12 680 XV374 9T17A1453G63
75 (+2, -4 2.5%) 12 830 XV375 9T17A1454G63
1See page 10-45 for wiring diagrams.

Rev. 11/13 www.geindustrial.com BuyLogTM Catalog 10-29


Data subject to change
without notice
Page Updated 09 / 2016

Dry Type Transformers Section 10


Noise Isolation Guard II
Copper
Three-Phase DOE 2016 Efficiency

150C Rise
Input Output Wiring Approx Net Frame Product
Voltage Voltage kVA Taps Diagram No.1 Weight (Lbs) Size Number
15 (+2, -4 2.5%) 12 270 XV371 9T17C1001G03
30 (+2, -4 2.5%) 12 420 XV372 9T17C1002G03
480 Volts Delta 208Y/120 Volts 45 (+2, -4 2.5%) 12 540 XV373 9T17C1003G03
75 (+2, -4 2.5%) 12 770 XV374 9T17C1004G03
112.5 (+2, -4 2.5%) 12 1010 XV375 9T17C1005G03

115C Rise
Input Output Wiring Approx Net Frame Product
Voltage Voltage kVA Taps Diagram No.1 Weight (Lbs) Size Number
15 (+2, -4 2.5%) 12 270 XV371 9T17C1001G33
30 (+2, -4 2.5%) 12 420 XV372 9T17C1002G33
480 Volts Delta 208Y/120 Volts 45 (+2, -4 2.5%) 12 540 XV373 9T17C1003G33
75 (+2, -4 2.5%) 12 770 XV374 9T17C1004G33
112.5 (+2, -4 2.5%) 12 1010 XV375 9T17C1005G33

80C Rise
Input Output Wiring Approx Net Frame Product
Voltage Voltage kVA Taps Diagram No.1 Weight (Lbs) Size Number
15 (+2, -4 2.5%) 12 420 XV372 9T17C1001G63
30 (+2, -4 2.5%) 12 540 XV373 9T17C1002G63
480 Volts Delta 208Y/120 Volts
45 (+2, -4 2.5%) 12 770 XV374 9T17C1003G63
75 (+2, -4 2.5%) 12 1010 XV375 9T17C1004G63

150C Rise
Input Output Wiring Approx Net Frame Product
Voltage Voltage kVA Taps Diagram No.1 Weight (Lbs) Size Number
15 (+2, -4 2.5%) 12 270 XV371 9T17C1451G03
30 (+2, -4 2.5%) 12 420 XV372 9T17C1452G03
208 Volts Delta 208Y/120 Volts 45 (+2, -4 2.5%) 12 540 XV373 9T17C1453G03
75 (+2, -4 2.5%) 12 770 XV374 9T17C1454G03
112.5 (+2, -4 2.5%) 12 1010 XV375 9T17C1455G03

115C Rise
Input Output Wiring Approx Net Frame Product
Voltage Voltage kVA Taps Diagram No.1 Weight (Lbs) Size Number
15 (+2, -4 2.5%) 12 270 XV371 9T17C1451G33
30 (+2, -4 2.5%) 12 420 XV372 9T17C1452G33
208 Volts Delta 208Y/120 Volts 45 (+2, -4 2.5%) 12 540 XV373 9T17C1453G33
75 (+2, -4 2.5%) 12 770 XV374 9T17C1454G33
112.5 (+2, -4 2.5%) 12 1010 XV375 9T17C1455G33
1See page 10-45 for wiring diagrams.

10-30 BuyLogTM Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Dry Type Transformers Section 10
Harmonic Mitigating Guard III
Copper
Three-Phase DOE 2016 Efficiency

150C Rise NEMA 2, 0 Phase Shift


Input Output Approx Net Frame Product
Voltage Voltage kVA Weight (Lbs) Size Number
480 208Y/120 15 318 H371C 9T76H9871G03
480 208Y/120 30 552 H372C 9T76H9872G03
480 208Y/120 45 643 H373C 9T76H9873G03
480
480 208Y/120
208Y/120 75 1053 H374C 9T76H9874G03
480 208Y/120 112.5 1980 H375C 9T76H9875G03
480 208Y/120 150 2125 H376C 9T76H9876G03
480 208Y/120 225 XV377 9T76H9877G03
480 208Y/120 300 3170 YF378 9T76H9878G03

150C Rise NEMA 2, -30 Phase Shift


Input Output Approx Net Frame Product
Voltage Voltage kVA Weight (Lbs) Size Number
480 208Y/120 15 318 H371C 9T77H9871G03
480 208Y/120 30 552 H372C 9T77H9872G03
480 208Y/120 45 643 H373C 9T77H9873G03
480 208Y/120
208Y/120 75 1053 H374C 9T77H9874G03
480 208Y/120 112.5 1980 H375C 9T77H9875G03
480 208Y/120 150 2125 H376C 9T77H9876G03
480 208Y/120 225 XV377 9T77H9877G03
480 208Y/120 300 3170 YF378 9T77H9878G03

Rev. 11/13 www.geindustrial.com BuyLogTM Catalog 10-31


Data subject to change
without notice
Dry Type Transformers Section 10
Servicenter Mini-Unit Substations
Integral Transformer and Distribution Center

Product Description Application


This easily installed and serviceable unit incorporates a Type QMS The single-phase Servicenter can be used wherever 480 Volt
transformer (single-phase) or a Type QL transformer (three- power is available and 120 or 240 Volt branch circuits are
phase), a primary main circuit breaker, a secondary main circuit required. The three-phase Servicenter can be used wherever 240
breaker, and a load-center-design breaker panel. Since these Volt, 480 Volt or 600 Volt is available and 208 Volt Y/120
components dont have to be installed and interconnected sepa- Volt circuits are required. The unit can be used in such applica-
rately, the contractor or user can reduce installation time and tions as vending machine areas, construction laboratory test
costs. Because of the single-unit concept, only one, handy areas, general construction sites where temporary or quickly
Servicenter needs to be mounted. obtained power is required, or where future expansion of branch
Available in single-phase, 5 through 25 kVA, and in three-phase, circuits is planned.
15 through 30 kVA, 600 Volt class ratings, the GE Servicenter is a Vending or concession areas
convenient, economical way to meet your industrial and tempo- Office buildings
rary power requirements. Assembly lines
The TransformerThe Servicenter utilizes GE transformer design Mining applications
which has twenty years of field-proven experience behind it and Parking lots
a long track record for assuring consistent, reliable performance. Light industrial areas
Type QMS transformers employ a 180C UL Recognized insulation Warehouses
system with a 115C rise. Type QL transformers employ a 220C Construction sites
UL Recognized insulation system with a 150C rise.
The PanelThe panel assembly includes the rugged GE NEC Requirements
PowerMark Plus circuit breaker load center interior, E-frame pri- The Servicenter conforms with Article 450-3 of the 1993 National
mary breakers, and E-frame or Q Line secondary breakers. The Electric Code.
load center will accept one-, two-, or three-pole (three-phase)
common trip circuit breakers and ground fault breakers. All
Servicenters come equipped with the properly sized primary main
and secondary main circuit breakers installed and prewired.
Branch breakers are not included.
Advantages
Transformer, distribution panel and breakers are all designed,
built and assembled by GE
Saves time and money - pre-assembled, pre-wired unit saves
time on the job
High reliability assembled and tested in our UL approved
factory to assure consistency and quality
Available GE ground-fault breakers ensure electrical safety
around construction sites or wherever water may be present
Key Features
Keyhole mounting flange facilitates easy mounting
Indoor and outdoor use Single-Phase Servicenter, Hinged Door Removed
Front-accessible, hinged or removable panel door is safe
and convenient
Heat barrier under core and coil provides electrical and thermal
isolation for wiring compartment
High-efficiency core construction results in quiet transformer
operation and low no-load losses
Factory installed and wired GE main and secondary main
circuit breakers

Three-Phase Servicenter, Closed View

10-32 BuyLogTM Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Page Updated 09 / 2016

Dry Type Transformers Section 10


Servicenter Mini-Unit Substations
Integral Transformer and Distribution Center
Single-Phase and Three-Phase DOE 2016 Efficiency

Single-Phase Servicenter

Single-Phase Indoor/Outdoor 60 Hz
Max. Branch Max. Branch Max. Branch Max. Branch
Input Output Spaces 1 THQL, Spaces 1 THQL, Spaces 1/2 THQP, Spaces 1/2 THQP, Total Breaker Rating- Breaker Rating- Product
Voltage Voltage kVA 1-pole 2-pole 1-pole 2-pole 1-pole Spaces Primary Main Secondary Main Number
5 6 3 12 4 12 25A 30A 9T21S1050
7.5 6 3 12 4 12 35A 40A 9T21S1070
480 Volts Delta 120/240 Volts 10 8 4 16 6 16 50A 50A 9T21S1100
15 12 6 24 10 24 60A 70A 9T21S1150
25 20 10 8 2 24 100A 150A 9T21S1250

Three-Phase2 Indoor/Outdoor 60 Hz1 DOE 2016 Efficiency Aluminum Transformer Windings


Input Output Max. Branch Max. Branch Total Breaker Rating- Breaker Rating- Product
Voltage Voltage kVA Spaces, 1-pole Spaces 3-pole 1-pole Spaces Primary Main Secondary Main Number
15 12 4 12 100A 50A 9T17A0001
240 Volts Delta 208Y/120 Volts 22.5 18 6 18 100A 70A 9T17A0002
30 24 8 24 100A 100A 9T17A0003
15 12 4 12 40A 50A 9T17A0011
480 Volts Delta 208Y/120 Volts 22.5 18 6 18 70A 70A 9T17A0012
30 24 8 24 90A 100A 9T17A0013
15 12 4 12 40A 50A 9T17A0021
600 Volts Delta 208Y/120 Volts 22.5 18 6 18 40A 70A 9T17A0022
30 24 8 24 40A 100A 9T17A0023

Three-Phase2 Indoor/Outdoor 60 Hz1 DOE 2016 Efficiency Copper Transformer Windings


Input Output Max. Branch Max. Branch Total Breaker Rating- Breaker Rating- Product
Voltage Voltage kVA Spaces, 1-pole Spaces 3-pole 1-pole Spaces Primary Main Secondary Main Number
15 12 4 12 100A 50A 9T17C0004
240 Volts Delta 208Y/120 Volts 22.5 18 6 18 100A 70A 9T17C0005
30 24 8 24 100A 100A 9T17C0006
15 12 4 12 40A 50A 9T17C0014
480 Volts Delta 208Y/120 Volts 22.5 18 6 18 70A 70A 9T17C0015
30 24 8 24 90A 100A 9T17C0016
15 12 4 12 40A 50A 9T17C0024
600 Volts Delta 208Y/120 Volts 22.5 18 6 18 40A 70A 9T17C0025
30 24 8 24 40A 100A 9T17C0026
1(3) 5% taps 1 above and 2 below rated primary volts.

2Three-Phase Servicenters may be ordered with a stainless steel enclosure. To order this option, replace the fifth character in the Product Number with the letterS.
For example: 9T17A0001 becomes 9T17S0001; 9T17C0004 becomes 9T17S0004.

Rev. 11/13 www.geindustrial.com BuyLogTM Catalog 10-33


Data subject to change
without notice
Dry Type Transformers Section 10
Servicenter Mini-Unit Substations
Integral Transformer and Distribution Center
Outlines, Dimensions and Wiring Diagrams

Single-Phase
Product Approx. Net "A" "B" "C" Frame
kVA Number Weight (Lbs.) Height (in.) Width (in.) Depth (in.) Size
5 9T21S1050 103 32.5 10.75 11.12 16350
7.5 9T21S1070 147 32.5 10.75 11.12 16600
10 9T21S1100 198 35 12.62 12.62 19400
15 9T21S1150 220 35 12.62 12.62 19500
25 9T21S1250 388 44.75 16.75 16 50500

Three-Phase DOE 2016 Efficiency Aluminum


Product Approx. Net "B" "A" Frame
kVA Number Weight (Lbs.) Height (in.) Width (in.) Depth (in.) Size
15 9T17A0001 280 27.3 27.4 16.9 UX71A
22.5 9T17A0002 450 32.2 34.5 24 UX72A
30 9T17A0003 450 32.2 34.5 24 UX72A
15 9T17A0011 280 27.3 27.4 16.9 UX71A Dimensions Single-Phase
22.5 9T17A0012 450 32.2 34.5 24 UX72A
30 9T17A0013 450 32.2 34.5 24 UX72A
15 9T17A0021 280 27.3 27.4 16.9 UX71A
22.5 9T17A0022 450 32.2 34.5 24 UX72A
30 9T17A0023 450 32.2 34.5 24 UX72A

Three-Phase DOE 2016 Efficiency Copper


Product Approx Net "A" "B" "C" Frame
kVA Number Weight (Lbs) Height (in.) Height (in.) Height (in.) Size
15 9T17C0004 290 27.3 27.4 16.9 UX71C
22.5 9T17C0005 460 32.2 34.5 24 UX72C
30 9T17C0006 460 32.2 34.5 24 UX72C
15 9T17C0014 290 27.3 27.4 16.9 UX71C
22.5 9T17C0015 460 32.2 34.5 24 UX72C
30 9T17C0016 460 32.2 34.5 24 UX72C
15 9T17C0024 290 27.3 27.4 16.9 UX71C
22.5 9T17C0025 460 32.2 34.5 24 UX72C
30 9T17C0026 460 32.2 34.5 24 UX72C
Dimensions Three-Phase

Typical Wiring Diagram Single-Phase Typical Wiring Diagram Three-Phase 1


1For 22.5 and 15 kVA three-phase Servicenters, secondary main
breaker is a backfed plug-in type with positive retainers.

10-34 BuyLogTM Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Dry Type Transformers Section 10
Totally Enclosed, Nonventilated
TENV
15-75kVA, Three-Phase, NEMA TP-1 Efficiency

Totally enclosed nonventilated (TENV) transformers are an


excellent choice for applications where dry-type transformer
benefits are desired but the standard enclosure openings are
unacceptable because of adverse atmospheric conditions. TENV
transformers are recommended where dust, dirt or lint may be
present or where transformers are subject to sprays or controlled
wash-down conditions. They are UL Listed through 75kVA for
indoor or protected outdoor applications.

Advantages
Dry-type transformer is housed in an enclosed NEMA 3R
non-ventilated compartment
Convenient wiring compartment is located beneath the
transformer and has removable front and rear covers
Copper bus bars are located at the front of the wiring
compartment and are clearly labeled
All electrical connections between the transformer and
TENV Transformer
bus bars are factory wired
Quiet performance meets NEMA ST-20
No-weld coil termination design an industry first
Comprehensive factory testing assures quality

Features
Quiet design - unique core and coil design makes GE TENV
transformers among the quietest available
Core and coil assembly mounted on rubber isolation pads to
reduce noise
Bolted coil terminations are more reliable than welded
terminations, and they eliminate weld failures and problems
associated with welding and weld splatter
100% factory tested for shorts and coil integrity, current and
loss, voltage, impedance and noise
Qualified to the seismic requirements of IEEE-693-2005 and
IBC-2012/CBC-2013
Copper ground strap
Copper or aluminum windings available
Available in 150C, 115C, and 80C rise models
Indoor or outdoor use

Applications
Textile
Automotive
Foundry
Paper mills
Wash-down areas

Rev. 11/13 www.geindustrial.com BuyLogTM Catalog 10-35


Data subject to change
without notice
Dry Type Transformers Section 10
Totally Enclosed, Nonventilated
TENV
Three-Phase DOE 2016 Efficiency

Aluminum 150C Rise


Input Output Net
Voltage Voltage kVA Taps Weight (Lbs.) Frame Size Product Number
480 208Y/120 15 (+2,-4 2.5%) 370 XV372 9T85B3871
480 208Y/120 30 (+2,-4 2.5%) 450 XV373 9T85B3872
480 208Y/120 45 (+2,-4 2.5%) 670 XV374 9T85B3873
480 208Y/120 75 (+2,-4 2.5%) 815 XV375 9T85B3874

Aluminum 115C Rise


Input Output Net
Voltage Voltage kVA Taps Weight (Lbs.) Frame Size Product Number
480 208Y/120 15 (+2,-4 2.5%) 370 XV372 9T85B3871G15
480 208Y/120 30 (+2,-4 2.5%) 450 XV373 9T85B3872G15
480 208Y/120 45 (+2,-4 2.5%) 670 XV374 9T85B3873G15
480 208Y/120 75 (+2,-4 2.5%) 815 XV375 9T85B3874G15

Aluminum 80C Rise


Input Output Net
Voltage Voltage kVA Taps Weight (Lbs.) Frame Size Product Number
480 208Y/120 30 (+2,-4 2.5%) 670 XV374 9T85B3872G80
480 208Y/120 45 (+2,-4 2.5%) 670 XV374 9T85B3873G80

Copper 150C Rise


Input Output Net
Voltage Voltage kVA Taps Weight (Lbs.) Frame Size Product Number
480 208Y/120 15 (+2,-4 2.5%) 410 XV372 9T85C9871
480 208Y/120 30 (+2,-4 2.5%) 525 XV373 9T85C9872
480 208Y/120 45 (+2,-4 2.5%) 760 XV374 9T85C9873
480 208Y/120 75 (+2,-4 2.5%) 1000 XV375 9T85C9874

Copper 115C Rise


Input Output Net
Voltage Voltage kVA Taps Weight (Lbs.) Frame Size Product Number
480 208Y/120 15 (+2,-4 2.5%) 410 XV372 9T85C9871G15
480 208Y/120 30 (+2,-4 2.5%) 525 XV373 9T85C9872G15
480 208Y/120 45 (+2,-4 2.5%) 760 XV374 9T85C9873G15
480 208Y/120 75 (+2,-4 2.5%) 1000 XV375 9T85C9874G15

Copper 80C Rise


Input Output Net
Voltage Voltage kVA Taps Weight (Lbs.) Frame Size Product Number
480 208Y/120 15 (+2,-4 2.5%) 410 XV372 9T85C9871G80
480 208Y/120 30 (+2,-4 2.5%) 760 XV374 9T85C9872G80
480 208Y/120 45 (+2,-4 2.5%) 760 XV374 9T85C9873G80

10-36 BuyLogTM Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Dry Type Transformers Section 10
Midtapped
Three-Phase DOE 2016 Efficiency
Product Description
GE Type QL midtapped transformer enables the user to transform
three-phase power from 480 Volts primary to 240 Volts second-
ary and have 120 Volt, reduced capacity tap (RCT) single-phase
capability as well. This is because a single-phase midtap is
brought out of one coil of the units three-phase secondary wind-
ing. These transformers are UL listed, File E-79145.
Application
The Type QL midtapped design can be used wherever there is 480
Volt, three-phase supply available and the load is primarily 240
Volt three-phase with a nominal amount of 120 Volt, single-phase
power required. Normally, in this instance, a small single-phase
as well as a three-phase transformer would be required to
provide the necessary transformation.
Caution: When utilizing the 120 Volt midtap for single-phase
applications, the single-phase load should not exceed 5 percent
of the three-phase kVA rating. The three-phase kVA load must be Type QL Midtapped Transformer
reduced by the same percentage as that added by the single-
phase load. Additional loading beyond 5 percent may cause the
transformer to overheat and fail. If the single-phase load is in
excess of 5 percent, it is recommended that a separate single-
phase unit be used to handle the load.

Aluminum
150C Rise 60Hz
Input Output Net
Voltage Voltage kVA Taps Weight (Lbs.) Frame Size Product Number
480 240/120 15 (+2,-4 2.5%) 231 UX71A 9T10A1181
480 240/120 30 (+2,-4 2.5%) 330 UX72A 9T10A1182
480 240/120 45 (+2,-4 2.5%) 444 UX73A 9T10A1183
480 240/120 75 (+2,-4 2.5%) 561 UY74A 9T10A1184
480 240/120 112.5 (+2,-4 2.5%) 830 DX75A 9T10A1185
480 240/120 150 (+2,-4 2.5%) 1030 DY76A 9T10A1186
480 240/120 225 (+2,-4 2.5%) 1450 DY77A 9T10A1187
480 240/120 300 (+2,-4 2.5%) 1670 DY78A 9T10A1188
480 240/120 500 (+2,-2 2.5%) 2900 DX79A 9T10A1189

115C Rise 60Hz


Input Output Net
Voltage Voltage kVA Taps Weight (Lbs.) Frame Size Product Number
480 240/120 15 (+2,-4 2.5%) 231 UX71A 9T10A1181G31
480 240/120 30 (+2,-4 2.5%) 330 UX72A 9T10A1182G31
480 240/120 45 (+2,-4 2.5%) 444 UX73A 9T10A1183G31
480 240/120 75 (+2,-4 2.5%) 603 UX74A 9T10A1184G31
480 240/120 112.5 (+2,-4 2.5%) 830 DX75A 9T10A1185G31
480 240/120 150 (+2,-4 2.5%) 1250 DX76A 9T10A1186G31
480 240/120 225 (+2,-4 2.5%) 1670 DX77A 9T10A1187G31
480 240/120 300 (+2,-4 2.5%) 1985 DX78A 9T10A1188G31
480 240/120 500 (+2,-2 2.5%) 2900 DX79A 9T10A1189G31

80C Rise 60Hz


Input Output Net
Voltage Voltage kVA Taps Weight (Lbs.) Frame Size Product Number
480 240/120 15 (+2,-4 2.5%) 330 UX72A 9T10A1181G61
480 240/120 30 (+2,-4 2.5%) 444 UX73A 9T10A1182G61
480 240/120 45 (+2,-4 2.5%) 561 UY74A 9T10A1183G61
480 240/120 75 (+2,-4 2.5%) 680 DY75A 9T10A1184G61
480 240/120 150 (+2,-4 2.5%) 1450 DY77A 9T10A1186G61
480 240/120 225 (+2,-4 2.5%) 1985 DX78A 9T10A1187G61

Rev. 11/13 www.geindustrial.com BuyLogTM Catalog 10-37


Data subject to change
without notice
Dry Type Transformers Section 10
Midtapped
Aluminum
Three-Phase DOE 2016 Efficiency

150C Rise 60Hz Low Noise (-3dB)


Input Output Net
Voltage Voltage kVA Taps Weight (Lbs.) Frame Size Product Number
480 240/120 15 (+2,-4 2.5%) 231 UX71A 9T10A1181G02
480 240/120 30 (+2,-4 2.5%) 330 UX72A 9T10A1182G02
480 240/120 45 (+2,-4 2.5%) 444 UX73A 9T10A1183G02
480 240/120 75 (+2,-4 2.5%) 561 UY74A 9T10A1184G02
480 240/120 112.5 (+2,-4 2.5%) 680 DX75A 9T10A1185G02
480 240/120 150 (+2,-4 2.5%) 1030 DY76A 9T10A1186G02
480 240/120 225 (+2,-4 2.5%) 1450 DY77A 9T10A1187G02
480 240/120 300 (+2,-4 2.5%) 1670 DY78A 9T10A1188G02
480 240/120 500 (+2,-2 2.5%) 2900 DX79A 9T10A1189G02

115C Rise 60Hz Low Noise (-3dB)


Input Output Net
Voltage Voltage kVA Taps Weight (Lbs.) Frame Size Product Number
480 240/120 15 (+2,-4 2.5%) 231 UX71A 9T10A1181G32
480 240/120 30 (+2,-4 2.5%) 330 UX72A 9T10A1182G32
480 240/120 45 (+2,-4 2.5%) 444 UX73A 9T10A1183G32
480 240/120 75 (+2,-4 2.5%) 603 UX74A 9T10A1184G32
480 240/120 112.5 (+2,-4 2.5%) 830 DX75A 9T10A1185G32
480 240/120 150 (+2,-4 2.5%) 1250 DX76A 9T10A1186G32
480 240/120 225 (+2,-4 2.5%) 1670 DX77A 9T10A1187G32
480 240/120 300 (+2,-4 2.5%) 1985 DX78A 9T10A1188G32
480 240/120 500 (+2,-2 2.5%) 2900 DX79A 9T10A1189G32

10-38 BuyLogTM Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Dry Type Transformers Section 10
Midtapped
Copper
Three-Phase DOE 2016 Efficiency

150C Rise 60Hz


Input Output Net
Voltage Voltage kVA Taps Weight (Lbs.) Frame Size Product Number
480 240/120 15 (+2,-4 2.5%) 230 UX71C 9T10C1181
480 240/120 30 (+2,-4 2.5%) 353 UX72C 9T10C1182
480 240/120 45 (+2,-4 2.5%) 480 UX73C 9T10C1183
480 240/120 75 (+2,-4 2.5%) 661 UY74C 9T10C1184
480 240/120 112.5 (+2,-4 2.5%) 790 DY75C 9T10C1185
480 240/120 150 (+2,-4 2.5%) 1085 DY76C 9T10C1186
480 240/120 225 (+2,-4 2.5%) 1610 DY77C 9T10C1187
480 240/120 300 (+2,-4 2.5%) 1970 DY78C 9T10C1188
480 240/120 500 (+2,-2 2.5%) 3720 DX79C 9T10C1189

115C Rise 60Hz


Input Output Net
Voltage Voltage kVA Taps Weight (Lbs.) Frame Size Product Number
480 240/120 15 (+2,-4 2.5%) 230 UX71C 9T10C1181G31
480 240/120 30 (+2,-4 2.5%) 353 UX72C 9T10C1182G31
480 240/120 45 (+2,-4 2.5%) 480 UX73C 9T10C1183G31
480 240/120 75 (+2,-4 2.5%) 748 UX74C 9T10C1184G31
480 240/120 112.5 (+2,-4 2.5%) 900 DX75C 9T10C1185G31
480 240/120 150 (+2,-4 2.5%) 1240 DX76C 9T10C1186G31
480 240/120 225 (+2,-4 2.5%) 1847 DX77C 9T10C1187G31
480 240/120 300 (+2,-4 2.5%) 2150 DX78C 9T10C1188G31
480 240/120 500 (+2,-2 2.5%) 3720 DX79C 9T10C1189G31

80C Rise 60Hz


Input Output Net
Voltage Voltage kVA Taps Weight (Lbs.) Frame Size Product Number
480 240/120 15 (+2,-4 2.5%) 353 UX72C 9T10C1181G61
480 240/120 30 (+2,-4 2.5%) 480 UX73C 9T10C1182G61
480 240/120 45 (+2,-4 2.5%) 661 UY74C 9T10C1183G61
480 240/120 75 (+2,-4 2.5%) 790 DY75C 9T10C1184G61
480 240/120 112.5 (+2,-4 2.5%) 1085 DY76C 9T10C1185G61
480 240/120 150 (+2,-4 2.5%) 1610 DY77C 9T10C1186G61
480 240/120 225 (+2,-4 2.5%) 2150 DX78C 9T10C1187G61
480 240/120 300 (+2,-2 2.5%) 3720 DX79C 9T10C1188G61

150C Rise 60Hz Low Noise (-3dB)


Input Output Net
Voltage Voltage kVA Taps Weight (Lbs.) Frame Size Product Number
480 240/120 15 (+2,-4 2.5%) 230 UX71C 9T10C1181G02
480 240/120 30 (+2,-4 2.5%) 353 UX72C 9T10C1182G02
480 240/120 45 (+2,-4 2.5%) 480 UX73C 9T10C1183G02
480 240/120 75 (+2,-4 2.5%) 661 UY74C 9T10C1184G02
480 240/120 112.5 (+2,-4 2.5%) 790 DY75C 9T10C1185G02
480 240/120 150 (+2,-4 2.5%) 1085 DY76C 9T10C1186G02
480 240/120 225 (+2,-4 2.5%) 1610 DY77C 9T10C1187G02
480 240/120 300 (+2,-4 2.5%) 1970 DY78C 9T10C1188G02
480 240/120 500 (+2,-2 2.5%) 3720 DX79C 9T10C1189G02

115C Rise 60Hz Low Noise (-3dB)


Input Output Net
Voltage Voltage kVA Taps Weight (Lbs.) Frame Size Product Number
480 240/120 15 (+2,-4 2.5%) 230 UX71C 9T10C1181G32
480 240/120 30 (+2,-4 2.5%) 353 UX72C 9T10C1182G32
480 240/120 45 (+2,-4 2.5%) 480 UX73C 9T10C1183G32
480 240/120 75 (+2,-4 2.5%) 748 UX74C 9T10C1184G32
480 240/120 112.5 (+2,-4 2.5%) 900 DX75C 9T10C1185G32
480 240/120 150 (+2,-4 2.5%) 1240 DX76C 9T10C1186G32
480 240/120 225 (+2,-4 2.5%) 1847 DX77C 9T10C1187G32
480 240/120 300 (+2,-4 2.5%) 2150 DX78C 9T10C1188G32
480 240/120 500 (+2,-2 2.5%) 3720 DX79C 9T10C1189G32

80C Rise 60Hz Low Noise (-3dB)


Input Output Net
Voltage Voltage kVA Taps Weight (Lbs.) Frame Size Product Number
480 240/120 15 (+2,-4 2.5%) 353 UX72C 9T10C1181G62
480 240/120 30 (+2,-4 2.5%) 480 UX73C 9T10C1182G62
480 240/120 45 (+2,-4 2.5%) 661 UY74C 9T10C1183G62
480 240/120 75 (+2,-4 2.5%) 790 DY75C 9T10C1184G62
480 240/120 112.5 (+2,-4 2.5%) 1085 DY76C 9T10C1185G62
480 240/120 150 (+2,-4 2.5%) 1610 DY77C 9T10C1186G62
480 240/120 225 (+2,-4 2.5%) 2150 DX78C 9T10C1187G62
480 240/120 300 (+2,-2 2.5%) 3720 DX79C 9T10C1188G62

Rev. 11/13 www.geindustrial.com BuyLogTM Catalog 10-39


Data subject to change
without notice
Dry Type Transformers Section 10
Drive Isolation
Aluminum
Three-Phase

Application
The use of SCR control circuitry with adjustable-speed drives has with SCR drives. Isolation transformers also reduce line-pollution
resulted in a need for a line of isolation transformers specifically feedback resulting from SCR firing circuits. The GE delta-wye
designed to meet the demanding requirements of SCR drives. designs meet the NEC requirements for grounded secondary
Symmetrically placed taps and added coil bracing minimize neutrals that isolate primary distribution systems. kVA ratings of
mechanical forces caused by the often severe SCR drive duty the DIT line cover most dc motor requirements from 3 to 1000 hp.
cycles. These features also help protect the transformer from the Enclosed drive isolation transformers are UL listed.
regenerative duty and more frequent short-circuits associated

15 - 220 kVA Indoor Type QL UL Listed


Input Output Wiring Weight Frame Product
Voltage Voltage kVA Frequency (Hz) Diagram No.1 (Lbs) Size Number
230 Volts Delta 230Y/133 Volts 15 60Hz 16 240 XV371 9T83B4000G29
230 Volts Delta 230Y/133 Volts 20 60Hz 16 334 XV372 9T83B4001G29
230 Volts Delta 230Y/133 Volts 27 60Hz 16 334 XV372 9T83B4002G29
230 Volts Delta 230Y/133 Volts 34 60Hz 16 334 XV372 9T83B4003G29
230 Volts Delta 230Y/133 Volts 40 60Hz 16 415 XV373 9T83B4004G29
230 Volts Delta 230Y/133 Volts 51 60Hz 16 415 XV373 9T83B4005G29
230 Volts Delta 230Y/133 Volts 63 60Hz 16 620 XV374 9T83B4006G29
230 Volts Delta 230Y/133 Volts 75 60Hz 16 620 XV374 9T83B4007G29
230 Volts Delta 230Y/133 Volts 93 60Hz 16 765 XV375 9T83B4008G29
230 Volts Delta 230Y/133 Volts 118 60Hz 16 1070 XV376 9T83B4009G29
230 Volts Delta 230Y/133 Volts 145 60Hz 16 1070 XV376 9T83B4010G29
230 Volts Delta 230Y/133 Volts 175 60Hz 16 1590 XV377 9T83B4011G29
230 Volts Delta 230Y/133 Volts 220 60Hz 16 1590 XV377 9T83B4012G29
230 Volts Delta 460Y/266 Volts 15 60Hz 16 240 XV371 9T83B4000G28
230 Volts Delta 460Y/266 Volts 20 60Hz 16 334 XV372 9T83B4001G28
230 Volts Delta 460Y/266 Volts 27 60Hz 16 334 XV372 9T83B4002G28
230 Volts Delta 460Y/266 Volts 34 60Hz 16 334 XV372 9T83B4003G28
230 Volts Delta 460Y/266 Volts 40 60Hz 16 415 XV373 9T83B4004G28
230 Volts Delta 460Y/266 Volts 51 60Hz 16 415 XV373 9T83B4005G28
230 Volts Delta 460Y/266 Volts 63 60Hz 16 620 XV374 9T83B4006G28
230 Volts Delta 460Y/266 Volts 75 60Hz 16 620 XV374 9T83B4007G28
230 Volts Delta 460Y/266 Volts 93 60Hz 16 765 XV375 9T83B4008G28
230 Volts Delta 460Y/266 Volts 118 60Hz 16 1070 XV376 9T83B4009G28
230 Volts Delta 460Y/266 Volts 145 60Hz 16 1070 XV376 9T83B4010G28
230 Volts Delta 460Y/266 Volts 175 60Hz 16 1590 XV377 9T83B4011G28
230 Volts Delta 460Y/266 Volts 220 60Hz 16 1590 XV377 9T83B4012G28
1See page 10-45 for wiring diagrams.

10-40 BuyLogTM Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Dry Type Transformers Section 10
Drive Isolation
Aluminum
Three-Phase

15 - 220 kVA Indoor Type QL UL Listed (continued)


Input Output Wiring Weight Frame Product
Voltage Voltage kVA Frequency (Hz) Diagram No.1 (Lbs) Size Number
460 Volts Delta 230Y/133 15 60 Hz 16 240 XV371 9T83B4000G23
460 Volts Delta 230Y/133 20 60 Hz 16 334 XV372 9T83B4001G23
460 Volts Delta 230Y/133 27 60 Hz 16 334 XV372 9T83B4002G23
460 Volts Delta 230Y/133 34 60 Hz 16 334 XV372 9T83B4003G23
460 Volts Delta 230Y/133 40 60 Hz 16 415 XV373 9T83B4004G23
460 Volts Delta 230Y/133 51 60 Hz 16 415 XV373 9T83B4005G23
460 Volts Delta 230Y/133 63 60 Hz 16 620 XV374 9T83B4006G23
460 Volts Delta 230Y/133 75 60 Hz 16 620 XV374 9T83B4007G23
460 Volts Delta 230Y/133 93 60 Hz 16 765 XV375 9T83B4008G23
460 Volts Delta 230Y/133 118 60 Hz 16 1070 XV376 9T83B4009G23
460 Volts Delta 230Y/133 145 60 Hz 16 1070 XV376 9T83B4010G23
460 Volts Delta 230Y/133 175 60 Hz 16 1590 XV377 9T83B4011G23
460 Volts Delta 230Y/133 220 60 Hz 16 1590 XV377 9T83B4012G23
460 Volts Delta 460Y/266 15 60 Hz 16 240 XV371 9T83B4000G22
460 Volts Delta 460Y/266 20 60 Hz 16 334 XV372 9T83B4001G22
460 Volts Delta 460Y/266 27 60 Hz 16 334 XV372 9T83B4002G22
460 Volts Delta 460Y/266 34 60 Hz 16 334 XV372 9T83B4003G22
460 Volts Delta 460Y/266 40 60 Hz 16 415 XV373 9T83B4004G22
460 Volts Delta 460Y/266 51 60 Hz 16 415 XV373 9T83B4005G22
460 Volts Delta 460Y/266 63 60 Hz 16 620 XV374 9T83B4006G22
460 Volts Delta 460Y/266 75 60 Hz 16 620 XV374 9T83B4007G22
460 Volts Delta 460Y/266 93 60 Hz 16 765 XV375 9T83B4008G22
460 Volts Delta 460Y/266 118 60 Hz 16 1070 XV376 9T83B4009G22
460 Volts Delta 460Y/266 145 60 Hz 16 1070 XV376 9T83B4010G22
460 Volts Delta 460Y/266 175 60 Hz 16 1590 XV377 9T83B4011G22
460 Volts Delta 460Y/266 220 60 Hz 16 1590 XV377 9T83B4012G22
575 Volts Delta 230Y/133 15 60 Hz 16 240 XV371 9T83B4000G27
575 Volts Delta 230Y/133 20 60 Hz 16 334 XV372 9T83B4001G27
575 Volts Delta 230Y/133 27 60 Hz 16 334 XV372 9T83B4002G27
575 Volts Delta 230Y/133 34 60 Hz 16 334 XV372 9T83B4003G27
575 Volts Delta 230Y/133 40 60 Hz 16 415 XV373 9T83B4004G27
575 Volts Delta 230Y/133 51 60 Hz 16 415 XV373 9T83B4005G27
575 Volts Delta 230Y/133 63 60 Hz 16 620 XV374 9T83B4006G27
575 Volts Delta 230Y/133 75 60 Hz 16 620 XV374 9T83B4007G27
575 Volts Delta 230Y/133 93 60 Hz 16 765 XV375 9T83B4008G27
575 Volts Delta 230Y/133 118 60 Hz 16 1070 XV376 9T83B4009G27
575 Volts Delta 230Y/133 145 60 Hz 16 1070 XV376 9T83B4010G27
575 Volts Delta 230Y/133 175 60 Hz 16 1590 XV377 9T83B4011G27
575 Volts Delta 230Y/133 220 60 Hz 16 1590 XV377 9T83B4012G27
575 Volts Delta 460Y/266 15 60 Hz 16 240 XV371 9T83B4000G26
575 Volts Delta 460Y/266 20 60 Hz 16 334 XV372 9T83B4001G26
575 Volts Delta 460Y/266 27 60 Hz 16 334 XV372 9T83B4002G26
575 Volts Delta 460Y/266 34 60 Hz 16 334 XV372 9T83B4003G26
575 Volts Delta 460Y/266 40 60 Hz 16 415 XV373 9T83B4004G26
575 Volts Delta 460Y/266 51 60 Hz 16 415 XV373 9T83B4005G26
575 Volts Delta 460Y/266 63 60 Hz 16 620 XV374 9T83B4006G26
575 Volts Delta 460Y/266 75 60 Hz 16 620 XV374 9T83B4007G26
575 Volts Delta 460Y/266 93 60 Hz 16 765 XV375 9T83B4008G26
575 Volts Delta 460Y/266 118 60 Hz 16 1070 XV376 9T83B4009G26
575 Volts Delta 460Y/266 145 60 Hz 16 1070 XV376 9T83B4010G26
575 Volts Delta 460Y/266 175 60 Hz 16 1590 XV377 9T83B4011G26
575 Volts Delta 460Y/266 220 60 Hz 16 1590 XV377 9T83B4012G26
1See page 10-45 for wiring diagrams.
NOTE: Full capacity symmetrical taps (1) +5% and (1) 5%, in primary windings for 230 and 460 Y thru 550 kVA; (1) +6.2% and (1) 6.2% at 750 kVA; (1) +6.4% and (1) 6.4%)
at 1000 kVA. With 575 V primary, symmetrical 5% taps apply thru 750 kVA; at 1000 kVA, (1) +5.1% and (1) 5.1%. For ratings less than 15 kV contact GE Energy Sales
Office.

Conversion Chart
Decimal Fraction
.13 1/8
.38 3/8
.63 5/8
.88 7/8

Rev. 11/13 www.geindustrial.com BuyLogTM Catalog 10-41


Data subject to change
without notice
Dry Type Transformers Section 10
Accessories and Lugs
Single-Phase and Three-Phase
Wall Mount Bracket Ground Bar Kit Lug Kits for QL Transformers
Frame Size Product Number Frame Size Product Number Frame Size Product Number
UX71A 9T18Y1071G07 UX71A 9T18Y1071G11 UX71A 9T18Y1071G10
UX71C 9T18Y1071G07 UX71C 9T18Y1071G11 UX71C 9T18Y1071G10
UX72A 9T18Y1071G07 UX72A 9T18Y1071G11 UX72A 9T18Y1072G10
UX72C 9T18Y1071G07 UX73A 9T18Y1071G11 UX73A 9T18Y1072G10
UX73A 9T18Y1071G07 UX72C 9T18Y1071G11 UX72C 9T18Y1072G10
UX73C 9T18Y1071G07 UX73C 9T18Y1071G11 UX73C 9T18Y1072G10
UX74A 9T18Y1074G07 UY74A 9T18Y1074G11 UY74A 9T18Y1074G10
UX74C 9T18Y1074G07 UX74A 9T18Y1074G11 UX74A 9T18Y1074G10
UY74A 9T18Y1074G07 UY74C 9T18Y1074G11 UY74C 9T18Y1074G10
UY74C 9T18Y1074G07 UX74C 9T18Y1074G11 UX74C 9T18Y1074G10
DX75C 9T18Y1074G07 DY75A 9T18Y1074G11 DY75A 9T18Y1075G10
DY75A 9T18Y1074G07 DY76A 9T18Y1074G11 DY75C 9T18Y1075G10
DY75C 9T18Y1074G07 DY75C 9T18Y1074G11 DX75C 9T18Y1075G10
YF171 9T18Y5042 DY76C 9T18Y1074G11 DY76A 9T18Y1076G10
YF172 9T18Y5043 DX75A 9T18Y1074G11 DY76C 9T18Y1076G10
YF174 9T18Y5043 DX75C 9T18Y1074G11 DX75A 9T18Y1076G10
YF175 Not available DX76C 9T18Y1074G11 DX76C 9T18Y1076G10
YF176 Not available DY77A 9T18Y1077G10
YF177 Not available DY77C 9T18Y1077G10
DX76A 9T18Y1077G10
Rain Shield Kit DX77A 9T18Y1077G10
Frame Size Product Number DX77C 9T18Y1077G10
Bottom Pan UX71A 9T18Y1071G06 DY78A 9T18Y1078G10
Frame Size Product Number UX71C 9T18Y1071G06 DY78C 9T18Y1078G10
DX76A 9T18Y1077G09 UX72A 9T18Y1072G06 DX78A 9T18Y1078G10
DX77A 9T18Y1077G09 UX72C 9T18Y1072G06 DX78C 9T18Y1078G10
DX77C 9T18Y1077G09 UX73A 9T18Y1072G06 DX79A 9T18Y1079G10
DY77A 9T18Y1077G09 UX73C 9T18Y1072G06 DX79C 9T18Y1079G10
DY77C 9T18Y1077G09 UY74A 9T18Y1074G06 YF171 9T18Y7240G02
DX78A 9T18Y1078G09 UX74A 9T18Y1074G06 YF172 9T18Y7241G03
DX78C 9T18Y1078G09 UY74C 9T18Y1074G06 YF174 9T18Y7240G03
DY78A 9T18Y1078G09 UX74C 9T18Y1074G06 YF175 9T18Y7242G07
DY78C 9T18Y1078G09 DY75A 9T18Y1074G06 YF176 9T18Y7242G05
DX79A 9T18Y1079G09 DY75C 9T18Y1074G06 YF177 9T18Y7242G05
DX79C 9T18Y1079G09 DX75A 9T18Y1076G06
YF175 9T18Y4504G77 DX75C 9T18Y1074G06
YF176 9T18Y4504G79 DY76A 9T18Y1076G06
YF177 9T18Y4504G79 DY76C 9T18Y1076G06
DX76A 9T18Y1077G06
DX76C 9T18Y1076G06
DX77A 9T18Y1077G06
316 Stainless Steel Rain Shield Kit DX77C 9T18Y1077G06
Frame Size Product Number DY77A 9T18Y1077G06
UX71A 9T18Y1171G06 DY77C 9T18Y1077G06
UX71C 9T18Y1171G06 DY78C 9T18Y1077G06
UX72A 9T18Y1172G06 DY78A 9T18Y1077G06
UX73A 9T18Y1172G06 DX78A 9T18Y1077G06
UX72C 9T18Y1172G06 DX78C 9T18Y1077G06
UX73C 9T18Y1172G06 DX79A 9T18Y1079G06
UY74A 9T18Y1174G06 DX79C 9T18Y1079G06
UX74A 9T18Y1174G06 YF171 9T18Y4317G05
UY74C 9T18Y1174G06 YF172 9T18Y4317G06
UX74C 9T18Y1174G06 YF174 9T18Y4317G06
DY75A 9T18Y1174G06 YF175 9Y18Y4322G77
DY75C 9T18Y1174G06 YF176 9T18Y4322G79
DX75C 9T18Y1174G06 YF177 9T18Y4322G79
DY76A 9T18Y1176G06
DY76C 9T18Y1176G06
DX75A 9T18Y1176G06
DX76C 9T18Y1176G06

10-42 BuyLogTM Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Dry Type Transformers Section 10
Accessories and Lugs
Single-Phase and Three-Phase
Lug Kit Information for QL Transformers
Specified Lug Kit
Lug Size No.1 Lug Size No.2
Frame Typical Primary Bus Bar Secondary Bus Bar Kit Conductor Stud Conductor Stud
Size Transformer Size Holes (Qty/Size) Holes (Qty/Size) Number Qty Size Hole Size Qty Size Hole Size
YF171 1 ph - 15/25 kVA (2) .406 dia (2) .406 dia
(2670/2671) 9T18Y7240G021 8 6 AWG to 250 MCM 5/16 N/A N/A N/A
YF171 1 ph - 37.5 kVA (2) .563 dia (2) .563 dia
(2672)
YF172 1 ph - 50 kVA (2) .563 dia (2) .563 dia 9T18Y7241G03 4 6 AWG to 250 MCM 5/16 4 6 AWG to 350 MCM 3/8
(2673)
YF174 1 ph - 75 kVA (2) .563 dia (2) .563 dia 9T18Y7240G03 12 6 AWG to 250 MCM 5/16 N/A N/A N/A
(2674)
YF175 1 ph -100 kVA (2) .563 dia (2) .563 dia 9T18Y7242G07 12 6 AWG to 350 MCM 3/8 N/A N/A N/A
(2675)
YF176 1 ph - 167 kVA (4) .563 dia (4) .563 dia 9T18Y7242G05 8 6 AWG to 350 MCM 3/8 12 4 AWG to 500 MCM 3/8
(2676)
UX71A/UX71C 3 ph - 15 kVA (2) .406 dia (2) .406 dia 9T18Y1071G101 7 14 AWG to 1/0 AWG 1/4 N/A N/A N/A
(001)
UX72A/UX72C/ 3 ph - 30/45 kVA (2) .406 dia (2) .406 dia 9T18Y1072G101 7 6 AWG to 250 MCM 5/16 N/A N/A N/A
UX73A/UX73C (002/003)
UX74A/UX74C/ 3 ph - 75 kVA (2) .406 dia (2) .406 dia 9T18Y1074G10 3 6 AWG to 250 MCM 5/16 4 6 AWG to 350 MCM 3/8
UY74A/UY74C (004)
DX75C/DY75A 3 ph - 112.5 kVA (1) .563 dia (2) .563 dia 9T18Y1075G10 7 6 AWG to 350 MCM 3/8 N/A N/A N/A
DY75C (005)
DX75A/DX76C/ 3 ph - 150 kVA (1) .563 dia (2) .563 dia 9T18Y1076G10 3 6 AWG to 350 MCM 3/8 4 4 AWG to 500 MCM 3/8
DY76A/DY76C (006)
DX76A/DX77A 3 ph - 225 kVA (2) .563 dia (4) .563 dia 9T18Y1077G10 6 6 AWG to 350 MCM 3/8 8 4 AWG to 500 MCM 3/8
DX77C/DY77A (007)
DY77C
DX78A/DX78C 3 ph - 300 kVA (2) .563 dia (4) .563 dia 9T18Y1078G10 6 6 AWG to 350 MCM 3/8 6 2 AWG to 600 MCM 3/8
DY78A/DY78C (008)
DX79A/DX79C 3 ph - 400/500 kVA (4) .563 dia (6) .563 dia 9T18Y1079G10 9 6 AWG to 350 MCM 3/8 24 4 AWG to 500 MCM 3/8
(009)
1Proximity of bus bars would prohibit dual lugs per bus bar

Rev. 11/13 www.geindustrial.com BuyLog Catalog 10-43


Prices and data subject
to change without notice
Dry Type Transformers Section 10
Enclosure Parts

Enclosure Kits Front/Back Panel Side Panel Cover (Top) Panel


Frame Size Product Number Frame Size Product Number Frame Size Product Number Frame Size Product Number
UX71A 9T18Y1071 UX71A 9T18Y1071G03 UX71A 9T18Y1071G04 UX71A 9T18Y1071G05
UX71C 9T18Y1071 UX71C 9T18Y1071G03 UX71C 9T18Y1071G04 UX71C 9T18Y1071G05
UX72A 9T18Y1072 UX72A 9T18Y1072G03 UX72A 9T18Y1072G04 UX72A 9T18Y1072G05
UX73A 9T18Y1072 UX73A 9T18Y1072G03 UX73A 9T18Y1072G04 UX73A 9T18Y1072G05
UX72C 9T18Y1072 UX72C 9T18Y1072G03 UX72C 9T18Y1072G04 UX72C 9T18Y1072G05
UX73C 9T18Y1072 UX73C 9T18Y1072G03 UX73C 9T18Y1072G04 UX73C 9T18Y1072G05
UY74A 9T18Y1074 UY74A 9T18Y1074G03 UY74A 9T18Y1074G04 UY74A 9T18Y1074G05
UX74A 9T18Y1074 UX74A 9T18Y1074G03 UX74A 9T18Y1074G04 UX74A 9T18Y1074G05
UY74C 9T18Y1074 UY74C 9T18Y1074G03 UY74C 9T18Y1074G04 UY74C 9T18Y1074G05
UX74C 9T18Y1074 UX74C 9T18Y1074G03 UX74C 9T18Y1074G04 UX74C 9T18Y1074G05
DY75A 9T18Y1075 DY75A 9T18Y1075G03 DY75A 9T18Y1075G04 DY75A 9T18Y1074G05
DY75C 9T18Y1075 DY75C 9T18Y1075G03 DY75C 9T18Y1075G04 DY75C 9T18Y1074G05
DX75C 9T18Y1075 DX75C 9T18Y1075G03 DX75C 9T18Y1075G04 DX75C 9T18Y1074G05
DY76A 9T18Y1076 DY76A 9T18Y1076G03 DY76A 9T18Y1076G04 DY76A 9T18Y1076G05
DY76C 9T18Y1076 DY76C 9T18Y1076G03 DY76C 9T18Y1076G04 DY76C 9T18Y1076G05
DX75A 9T18Y1076 DX75A 9T18Y1076G03 DX75A 9T18Y1076G04 DX75A 9T18Y1076G05
DX76C 9T18Y1076 DX76C 9T18Y1076G03 DX76C 9T18Y1076G04 DX76C 9T18Y1076G05
DY77A 9T18Y1077 DY77A 9T18Y1077G03 DY77A 9T18Y1077G04 DY77A 9T18Y1077G05
DY77C 9T18Y1077 DY77C 9T18Y1077G03 DY77C 9T18Y1077G04 DY77C 9T18Y1077G05
DX76A 9T18Y1077 DX76A 9T18Y1077G03 DX76A 9T18Y1077G04 DX76A 9T18Y1077G05
DX77A 9T18Y1077 DX77A 9T18Y1077G03 DX77A 9T18Y1077G04 DX77A 9T18Y1077G05
DX77C 9T18Y1077 DX77C 9T18Y1077G03 DX77C 9T18Y1077G04 DX77C 9T18Y1077G05
DY78A 9T18Y1078 DY78A 9T18Y1078G03 DY78A 9T18Y1078G04 DY78A 9T18Y1078G05
DY78C 9T18Y1078 DY78C 9T18Y1078G03 DY78C 9T18Y1078G04 DY78C 9T18Y1078G05
DX78A 9T18Y1078 DX78A 9T18Y1078G03 DX78A 9T18Y1078G04 DX78A 9T18Y1078G05
DX78C 9T18Y1078 DX78C 9T18Y1078G03 DX78C 9T18Y1078G04 DX78C 9T18Y1078G05
DX79A 9T18Y1079 DX79A 9T18Y1079G03 DX79A 9T18Y1079G04 DX79A 9T18Y1079G05
DY79C 9T18Y1079 DY79C 9T18Y1079G03 DY79C 9T18Y1079G04 DY79C 9T18Y1079G05

COVER (TOP) COVER (TOP)


PANEL PANEL

SIDE PANEL SIDE PANEL

FRONT/BACK
PANEL
FRONT/BACK
PANEL

GRILL

BASE BOTTOM PAN


(NOT SHOWN)

ENCLOSURE KIT: 1 COVER + 2 SIDES + 2 FRONTS ENCLOSURE KIT: 1 COVER + 2 SIDES + 2 FRONTS

This style enclosure is used with the This style enclosure is used with the
following frames: following frames:
UX71A UY74C DX76A DX79A
UX71C UX74C DX76C DX79C
UX72A DY75A DX77A YF171
UX72C DY75C DX77C YF172
UX73A DX75A DY77A YF173
UX73C DX75C DY77C YF174
UY74A DY76A DY78C YF175
UX74A DY76C DY78A YF176
DX78A YF177
DX78C

10-44 BuyLogTM Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Dry Type Transformers Section 10
Wiring Diagrams

Diagram 1 Diagram 2 Diagram 3 Diagram 4

Diagram 5 Diagram 6 Diagram 7 Diagram 8

Diagram 9 Diagram 10 Diagram 11 Diagram 12

Diagram 13 Diagram 14 Diagram 15 Diagram 16

Diagram 17 Diagram 18 Diagram 19 Diagram 20

Diagram 21 Diagram 22 Diagram 23 Diagram 24

Rev. 11/13 www.geindustrial.com BuyLogTM Catalog 10-45


Data subject to change
without notice
Dry Type Transformers Section 10
Dimensions

1-Phase Vented QL Transformers


Frame Size Outline Drawing No. Height (In.) Width (In.) Depth (In.)
YF171 303B406AAP071 32.1 23.8 18.4
YF172 303B406AAP072 35.7 31.8 24
XV173 303B406AAP073 35.7 31.8 24
YF174 303B406AAP074 39.9 31.8 24
YF175 303B932AAP075 37.4 29.5 28.5
YF176 303B932AAP076 45.5 38.5 33
YF177 303B932AAP077 45.5 38.5 33

QL Transformer
3-Phase, Vented, Non-Fan Cooled QL Transformers (Front Panel Removed)
(9T8, 9T7, 9T6 models)
Includes General Purpose, K-Factor, K-Factor Low Noise,
Low Noise, Guard I, Midtapped, Drive Isolation
Enclosure Dimensions Mounting Feet Dimensions Weight
Frame Size Outline Drawing Width (in.) Depth (in.) Height (in.) Width (in.) Depth (in.) Painted (lbs.) 316 Stainless Steel (lbs.)
UX71A 303B111GEUXP71A 18.7 16.9 29.3 21.2 15.1 231 251
UX71C 303B111GEUXP71C 18.7 16.9 29.3 21.2 15.1 230 250
UX72A 303B111GEUXP72A 23.8 18.4 34.7 26.2 16.6 330 350
UX72C 303B111GEUXP72C 23.8 18.4 34.7 26.2 16.6 353 373
UX73A 303B111GEUXP73A 23.8 18.4 34.7 26.2 16.6 444 464
UX73C 303B111GEUXP73C 23.8 18.4 34.7 26.2 16.6 480 500
UY74A 303B111GEUYP74A 31.8 24 35.7 34.3 22.3 561 581
UY74C 303B111GEUYP74C 31.8 24 35.7 34.3 22.3 661 681
UX74A 303B111GEUXP74A 31.8 24 35.7 34.3 22.3 603 623
UX74C 303B111GEUXP74C 31.8 24 35.7 34.3 22.3 748 768
DY75A 303B111GEDYP75A 31.8 24 42.2 34.3 22.3 680 760
DY75C 303B111GEDYP75C 31.8 24 42.2 34.3 22.3 790 870
DX75A 303B111GEDXP75A 34.8 24 45.8 37.3 22.3 830 850
DX75C 303B111GEDXP75C 31.8 24 42.2 34.3 22.3 900 980
DY76A 303B111GEDYP76A 34.8 24 45.8 37.3 22.3 1030 1050
DY76C 303B111GEDYP76C 34.8 24 45.8 37.3 22.3 1085 1105
DX76A 303B112GEDXP76A 38.4 33 47.4 41.1 32 1250 Not available
DX76C 303B111GEDXP76C 34.8 24 45.8 37.3 22.3 1240 1260
DY77A 303B112GEDYP77A 38.4 33 47.4 41.4 32 1450 Not available
DY77C 303B112GEDYP77C 38.4 33 47.4 41.4 32 1610 Not available
DX77A 303B112GEDXP77A 38.4 33 47.4 41.4 32 1670 Not available
DY78A 303B112GEDYP78A 38.4 33 57.1 41.4 32 1670 Not available
DX77C 303B112GEDXP77C 38.4 33 47.4 41.4 32 1847 Not available
DY78C 303B112GEDYP78C 38.4 33 57.1 41.4 32 1970 Not available
DX78A 303B112GEDXP78A 38.4 33 57.1 41.4 32 1985 Not available
DX78C 303B112GEDXP78C 38.4 33 57.1 41.4 32 2150 Not available
DX79A 303B112GEDXP79A 46.5 37.8 65.7 50.1 37 2900 Not available
DX79C 303B112GEDXP79C 46.5 37.8 65.7 50.1 37 3720 Not available

Servicenter Transformers QMS Transformers


Frame Size Outline Drawing Height (in.) Width (In.) Depth (In.) Frame Size Outline Drawing Height (in.) Width (In.) Depth (In.)
16350 303B915AAP005 32.5 10.75 11.12 16350 303B923AAP005 14.5 10.62 11
16600 303B915AAP007 32.5 10.75 11.12 16400 303B923AAP005 14.5 10.62 11
19400 303B915AAP010 35 12.62 12.62 16450 303B923AAP005 14.5 10.62 11
19500 303B915AAP015 35 12.62 12.62 16600 303B923AAP007 17.06 10.62 11
50500 303B915AAP025 44.75 16.75 16 19400 303B923AAP010 17.06 12.5 12.5
XV371 303B404AAP015 27.3 27.4 16.9 19450 303B923AAP010 17.06 12.5 12.5
XV372 303B404AAP022 32.2 34.5 24 19500 303B915AAP015 35 12.62 12.62
XV372 303B404AAP030 32.2 34.5 24 1619 303B922AAP001 14.50 10.75 11.12
Y371C 303B404AAP015 27.3 27.4 16.9 1620 303B922AAP001 14.50 10.75 11.12
Y372C 303B404AAP022 32.2 34.5 24 1921 303B922AAP003 17.12 12.62 12.75
Y372C 303B404AAP030 32.2 34.5 24 1923 303B922AAP004 18.81 14.75 14.53
50500 303B915AAP025 44.75 16.75 16

10-46 BuyLogTM Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Dry Type Transformers Section 10
Dimensions

Guard II Transformers QB Transformers


Frame Size Outline Drawing No. Height (In.) Width (In.) Depth (In.) Frame Size Outline Drawing No. Height (In.) Width (In.) Depth (In.)
XV371 303B403AAP071 34.5 18.7 16.9 6100 303B920AAP001 6.38 5.12 3.25
XV372 303B403AAP072 41.3 23.8 18.4 6150 303B920AAP001 6.38 5.12 3.25
XV373 303B403AAP073 41.3 23.8 18.4 6200 303B920AAP001 6.38 5.12 3.25
XV374 303B403AAP074 44.8 31.8 24 8175 303B920AAP002 7.38 6.12 4.25
XV375 303B403AAP075 49.1 31.8 24 8200 303B920AAP002 7.38 6.12 4.25
10200 303B920AAP003 8.38 6.88 4.88
10225 303B920AAP003 8.38 6.88 4.88
Guard III Harmonic Mitigating 12200 303B920AAP004 9.62 7.88 5.5
Frame Size Outline Drawing No. Height (In.) Width (In.) Depth (In.) 12225 303B920AAP004 9.62 7.88 5.5
12275 303B920AAP004 9.62 7.88 5.5
H371C 303B431AAP071 32.3 23.8 18.4 12300 303B920AAP004 9.62 7.88 5.5
H372C 303B431AAP072 35.7 31.8 24 14200 303B920AAP005 11.12 9.38 6.72
H373C 303B431AAP073 35.7 31.8 24 14225 303B920AAP005 11.12 9.38 6.72
H374C 303B431AAP074 39.9 31.8 24 14250 303B920AAP005 11.12 9.38 6.72
H375C 303B931AAP075 45.5 38.6 33 14300 303B920AAP005 11.12 9.38 6.72
H376C 303B931AAP076 45.4 38.5 33 14350 303B920AAP005 11.12 9.38 6.72
14400 303B920AAP005 11.12 9.38 6.72

TENV Transformers
Frame Size Outline Drawing No. Height (In.) Width (In.) Depth (In.)
XV372 303B405AAP072 41.3 23.8 18.4
XV373 303B405AAP073 41.3 23.8 18.4
XV374 303B405AAP074 44.8 31.8 24
XV375 303B405AAP075 49.1 31.8 24

Rev. 11/13 www.geindustrial.com BuyLogTM Catalog 10-47


Data subject to change
without notice
Dry Type Transformers Section 10
General Purpose Encapsulated
Single-Phase NEMA 3R

.050 - 3 kVA Indoor/Outdoor Type QB UL Listed C-UL Listed


Input Output Frequency Wiring Weight Frame Product
Voltage Voltage kVA (Hz) Taps Diagram No.1 (Lbs) Size Number

240 x 480 Volts, 480 Volts 120/240 Volts 0.05 60 Hz No Taps 1 6 6100 9T51B0002
240 x 480 Volts 120/240 Volts 0.05 50 Hz No Taps 1 6 6100 9T51B0502
240 x 480 Volts, 480 Volts 120/240 Volts 0.075 60 Hz No Taps 1 6 6200 9T51B0003
240 x 480 Volts 120/240 Volts 0.075 50 Hz No Taps 1 6 6200 9T51B0503
240 x 480 Volts, 480 Volts 120/240 Volts 0.1 60 Hz No Taps 1 6 6200 9T51B0004
240 x 480 Volts 120/240 Volts 0.1 50 Hz No Taps 1 6 6200 9T51B0504
240 x 480 Volts, 480 Volts 120/240 Volts 0.15 60 Hz No Taps 1 10 8175 9T51B0005
240 x 480 Volts 120/240 Volts 0.15 50 Hz No Taps 1 10 8175 9T51B0505
240 x 480 Volts, 480 Volts 120/240 Volts 0.25 60 Hz No Taps 1 10 8175 9T51B0007
240 x 480 Volts 120/240 Volts 0.25 50 Hz No Taps 1 10 8200 9T51B0507
240 x 480 Volts, 480 Volts 120/240 Volts 0.5 60 Hz No Taps 1 16 10200 9T51B0008
240 x 480 Volts 120/240 Volts 0.5 50 Hz No Taps 1 20 10225 9T51B0508
240 x 480 Volts, 480 Volts 120/240 Volts 0.75 60 Hz No Taps 1 25 12200 9T51B0009
240 x 480 Volts 120/240 Volts 0.75 50 Hz No Taps 1 25 12225 9T51B0509
240 x 480 Volts, 480 Volts 120/240 Volts 1 60 Hz No Taps 1 25 12225 9T51B0010
240 x 480 Volts 120/240 Volts 1 50 Hz No Taps 1 30 12275 9T51B0510
240 x 480 Volts, 480 Volts 120/240 Volts 1.5 60 Hz No Taps 1 40 14200 9T51B0011
240 x 480 Volts 120/240 Volts 1.5 50 Hz No Taps 1 40 14225 9T51B0511
240 x 480 Volts, 480 Volts 120/240 Volts 2 60 Hz No Taps 1 45 14250 9T51B0012
240 x 480 Volts 120/240 Volts 2 50 Hz No Taps 1 50 14300 9T51B0512
240 x 480 Volts, 480 Volts 120/240 Volts 3 60 Hz No Taps 1 55 14350 9T51B0013
240 x 480 Volts 120/240 Volts 3 50 Hz No Taps 1 60 14400 9T51B0513
480 Volts 120/240 Volts 0.5 50 Hz (-2 5.0%) 2 20 10225 9T51B0548
480 Volts 120/240 Volts 0.75 50 Hz (-2 5.0%) 2 25 12200 9T51B0549
480 Volts 120/240 Volts 1 60 Hz (-2 5.0%) 2 25 12225 9T51B0050
480 Volts 120/240 Volts 1 50 Hz (-2 5.0%) 2 30 12275 9T51B0550
480 Volts 120/240 Volts 1.5 60 Hz (-2 5.0%) 2 40 14200 9T51B0051
480 Volts 120/240 Volts 1.5 50 Hz (-2 5.0%) 2 40 14225 9T51B0551
480 Volts 120/240 Volts 2 60 Hz (-2 5.0%) 2 45 14250 9T51B0052
480 Volts 120/240 Volts 2 50 Hz (-2 5.0%) 2 50 14300 9T51B0552
480 Volts 120/240 Volts 3 60 Hz (-2 5.0%) 2 55 14350 9T51B0053
480 Volts 120/240 Volts 3 60 Hz (+2,-2 2.5%) 3 55 14350 9T51B0135
480 Volts 120/240 Volts 3 50 Hz (-2 5.0%) 2 60 14400 9T51B0553
600 Volts 120/240 Volts 0.05 60 Hz No Taps 5 6 6100 9T51B0082
600 Volts 120/240 Volts 0.075 60 Hz No Taps 5 6 6200 9T51B0083
600 Volts 120/240 Volts 0.1 60 Hz No Taps 5 6 6200 9T51B0084
600 Volts 120/240 Volts 0.1 50 Hz No Taps 5 6 6200 9T51B0584
600 Volts 120/240 Volts 0.15 60 Hz No Taps 5 10 8175 9T51B0085
600 Volts 120/240 Volts 0.25 60 Hz No Taps 5 10 8175 9T51B0087
600 Volts 120/240 Volts 0.25 50 Hz No Taps 5 10 8200 9T51B0587
600 Volts 120/240 Volts 0.5 60 Hz No Taps 5 16 10200 9T51B0088
600 Volts 120/240 Volts 0.5 50 Hz (-2 5.0%) 2 20 10225 9T51B0568
600 Volts 120/240 Volts 0.75 60 Hz No Taps 5 25 12200 9T51B0089
600 Volts 120/240 Volts 0.75 50 Hz (-2 5.0%) 2 25 12200 9T51B0569
600 Volts 120/240 Volts 1 60 Hz (-2 5.0%) 2 25 12225 9T51B0070
600 Volts 120/240 Volts 1 60 Hz No Taps 5 25 12225 9T51B0090
600 Volts 120/240 Volts 1 50 Hz (-2 5.0%) 2 30 12275 9T51B0570
600 Volts 120/240 Volts 1.5 60 Hz (-2 5.0%) 2 40 14200 9T51B0071
600 Volts 120/240 Volts 1.5 60 Hz No Taps 5 40 14200 9T51B0091
600 Volts 120/240 Volts 1.5 50 Hz (-2 5.0%) 2 40 14225 9T51B0571
600 Volts 120/240 Volts 2 60 Hz (-2 5.0%) 2 45 14250 9T51B0072
600 Volts 120/240 Volts 2 60 Hz No Taps 5 45 14250 9T51B0092
600 Volts 120/240 Volts 2 50 Hz (-2 5.0%) 2 50 14300 9T51B0572
600 Volts 120/240 Volts 2 50 Hz No Taps 50 14300 9T51B0592
600 Volts 120/240 Volts 3 60 Hz (-2 5.0%) 2 55 14350 9T51B0073
600 Volts 120/240 Volts 3 60 Hz No Taps 5 55 14350 9T51B0093
600 Volts 120/240 Volts 3 50 Hz (-2 5.0%) 2 60 14400 9T51B0573
600 Volts 120/240 Volts 3 50 Hz No Taps 60 14400 9T51B0593
1See page 10-45 for wiring diagrams.

10-48 BuyLogTM Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Dry Type Transformers Section 10
General Purpose Encapsulated
Single-Phase NEMA 3R

.050 - 3 kVA Indoor/Outdoor Type QB UL Listed C-UL Listed


Input Output Frequency Wiring Weight Frame Product
Voltage Voltage kVA (Hz) Taps Diagram No.1 (Lbs) Size Number

120 x 240 Volts 120/240 Volts 0.05 60 Hz No Taps 1 6 6100 9T51B0022


120 x 240 Volts 120/240 Volts 0.1 60 Hz No Taps 1 6 6200 9T51B0024
120 x 240 Volts 120/240 Volts 0.15 60 Hz No Taps 1 10 8175 9T51B0025
120 x 240 Volts 120/240 Volts 0.25 60 Hz No Taps 1 10 8175 9T51B0027
120 x 240 Volts 120/240 Volts 0.5 60 Hz No Taps 1 16 10200 9T51B0028
120 x 240 Volts 120/240 Volts 0.75 60 Hz No Taps 1 25 12200 9T51B0029
120 x 240 Volts 120/240 Volts 1 60 Hz No Taps 1 25 12225 9T51B0030
120 x 240 Volts 120/240 Volts 1.5 60 Hz No Taps 1 40 14200 9T51B0031
120 x 240 Volts 120/240 Volts 2 60 Hz No Taps 1 45 14250 9T51B0032
120 x 240 Volts 120/240 Volts 3 60 Hz No Taps 1 60 14400 9T51B0033
208 Volts 120/240 Volts 0.5 60 Hz No Taps 4 16 10200 9T51B0158
208 Volts 120/240 Volts 0.75 60 Hz No Taps 4 25 12200 9T51B0159
208 Volts 120/240 Volts 1 60 Hz No Taps 4 25 12225 9T51B0160
208 Volts 120/240 Volts 2 60 Hz No Taps 4 45 14250 9T51B0156
208 Volts 120/240 Volts 3 60 Hz No Taps 4 55 14350 9T51B0157

.050 - 3 kVA Indoor/Outdoor Type QB UL Listed C-UL Listed


Input Output Frequency Wiring Weight Frame Product
Voltage Voltage kVA (Hz) Taps Diagram No.1 (Lbs) Size Number

277 Volts 120/240 Volts 0.25 60 Hz (-2 5.1%) 2 10 8175 9T51B0187


277 Volts 120/240 Volts 0.5 60 Hz (-2 5.1%) 2 16 10200 9T51B0188
277 Volts 120/240 Volts 0.75 60 Hz (-2 5.1%) 2 25 12200 9T51B0189
277 Volts 120/240 Volts 1 60 Hz (-2 5.1%) 2 30 12275 9T51B0190
277 Volts 120/240 Volts 1.5 60 Hz (-2 5.1%) 2 40 14200 9T51B0191
277 Volts 120/240 Volts 2 60 Hz (-2 5.1%) 2 45 14250 9T51B0192
277 Volts 120/240 Volts 3 60 Hz (-2 5.1%) 2 55 14350 9T51B0193
380/400/416 Volts 120/240 Volts 0.05 50 Hz No Taps 2 6 6150 9T51B0162
380/400/416 Volts 120/240 Volts 0.15 50 Hz No Taps 2 10 8175 9T51B0165
380/400/416 Volts 120/240 Volts 0.25 50 Hz No Taps 2 10 8200 9T51B0167
380/400/416 Volts 120/240 Volts 0.5 50 Hz No Taps 2 20 10225 9T51B0168
380/400/416 Volts 120/240 Volts 0.75 50 Hz No Taps 2 25 12200 9T51B0169
380/400/416 Volts 120/240 Volts 1 50 Hz No Taps 2 30 12275 9T51B0170
380/400/416 Volts 120/240 Volts 1.5 50 Hz No Taps 2 40 14225 9T51B0171
380/400/416 Volts 120/240 Volts 2 50 Hz No Taps 2 50 14300 9T51B0172
380/400/416 Volts 120/240 Volts 3 50 Hz No Taps 2 60 14400 9T51B0173
1See page 10-45 for wiring diagrams.

Rev. 11/13 www.geindustrial.com BuyLogTM Catalog 10-49


Data subject to change
without notice
Dry Type Transformers Section 10
General Purpose Encapsulated
Single-Phase NEMA 3R

5 - 25 kVA Indoor/Outdoor Type QMS 115C Rise UL Listed C-UL Listed


Input Output Frequency Wiring Weight Frame Product
Voltage Voltage kVA (Hz) Taps Diagram No.1 (Lbs) Size Number

120 x 240 Volts 120/240 Volts 5 60 Hz No Taps 1 103 16350 9T21B1001G02


120 x 240 Volts 120/240 Volts 7.5 60 Hz No Taps 1 147 16600 9T21B1002G02
120 x 240 Volts 120/240 Volts 10 60 Hz No Taps 1 198 19400 9T21B1003G02
120 x 240 Volts 120/240 Volts 10 60 Hz No Taps 1 198 19400 9T21B1054G02
120 x 240 Volts 120/240 Volts 15 60 Hz No Taps 1 220 19500 9T21B9101
120 x 240 Volts 120/240 Volts 15 60 Hz No Taps 1 233 19550 9T21B9131
120 x 240 Volts 120/240 Volts 25 60 Hz No Taps 1 233 19550 9T21B9102
208 Volts 120/240 Volts 5 60 Hz No Taps 4 103 16350 9T21B1028G02
208 Volts 120/240 Volts 7.5 60 Hz No Taps 4 147 16600 9T21B1029G02
208 Volts 120/240 Volts 10 60 Hz No Taps 4 198 19400 9T21B1030G02
208 Volts 120/240 Volts 15 60 Hz No Taps 4 220 19500 9T21B9119
208 Volts 120/240 Volts 25 60 Hz No Taps 4 388 50500 9T21B9120
1See page 10-45 for wiring diagrams.
2For Outdoor NEMA 3R Enclosure add suffix G62 to product number.

5 - 25 kVA Indoor/Outdoor Type QMS 115C Rise UL Listed C-UL Listed


Input Output Frequency Wiring Weight Frame Product
Voltage Voltage kVA (Hz) Taps Diagram No.1 (Lbs) Size Number

277 Volts 120/240 Volts 5 60 Hz (-2 5.1%) 2 103 16350 9T21B1046G02


277 Volts 120/240 Volts 5 60 Hz (-2 2.5%) 2 103 16350 9T21B1265G02
277 Volts 120/240 Volts 7.5 60 Hz (-2 5.1%) 2 147 16600 9T21B1047G02
277 Volts 120/240 Volts 10 60 Hz (-2 5.1%) 2 198 19400 9T21B1048G02
277 Volts 120/240 Volts 10 60 Hz (-2 2.5%) 2 198 19400 9T21B1266G02
277 Volts 120/240 Volts 15 60 Hz (-2 5.1%) 2 220 19500 9T21B9143
277 Volts 120/240 Volts 25 60 Hz (-2 4.7%) 2 388 50500 9T21B9144
1See page 10-45 for wiring diagrams.

5 - 25 kVA Indoor/Outdoor Type QMS 115C Rise UL Listed C-UL Listed


Input Output Frequency Wiring Weight Frame Product
Voltage Voltage kVA (Hz) Taps Diagram No.1 (Lbs) Size Number

240 x 480 Volts 120/240 Volts 5 60 No Taps 1 103 16350 9T21B1004G02


240 x 480 Volts 120/240 Volts 5 50 No Taps 1 115 16400 9T21B1055G02
240 x 480 Volts 120/240 Volts 7.5 60 No Taps 1 147 16600 9T21B1005G02
240 x 480 Volts 120/240 Volts 7.5 50 No Taps 1 174 16600 9T21B1056G02
240 x 480 Volts 120/240 Volts 10 60 No Taps 1 198 19400 9T21B1006G02
240 x 480 Volts 120/240 Volts 10 50 No Taps 1 198 19400 9T21B1057G02
240 x 480 Volts 120/240 Volts 15 60 No Taps 1 220 19500 9T21B9103
240 x 480 Volts 120/240 Volts 15 50 No Taps 1 233 19550 9T21B9133
240 x 480 Volts 120/240 Volts 25 60 No Taps 1 388 50500 9T21B9104
240 x 480 Volts 120/240 Volts 25 50 No Taps 1 428 50600 9T21B9134
480 Volts 120/240 Volts 5 60 (-2 5.0%) 2 103 16350 9T21B1007G02
480 Volts 120/240 Volts 5 60 (+2,-2 2.5%) 3 103 16350 9T21B1013G02
480 Volts 120/240 Volts 7.5 60 (-2 5.0%) 2 147 16600 9T21B1008G02
480 Volts 120/240 Volts 7.5 60 (+2,-2 2.5%) 3 147 16600 9T21B1014G02
480 Volts 120/240 Volts 10 60 (-2 4.9%) 2 198 19400 9T21B1009G02
480 Volts 120/240 Volts 10 60 (+2,-2 2.6%) 3 198 19400 9T21B1015G02
480 Volts 120/240 Volts 15 60 (-2 5.0%) 2 220 19500 9T21B9105
480 Volts 120/240 Volts 15 60 (+2,-2 2.5%) 3 220 19500 9T21B9109
480 Volts 120/240 Volts 25 60 (-2 5.0%) 2 388 50500 9T21B9106
480 Volts 120/240 Volts 25 60 (+2,-2 2.5%) 3 388 50500 9T21B9110
600 Volts 120/240 Volts 5 60 No Taps 5 103 16350 9T21B1016G02
600 Volts 120/240 Volts 5 60 (-2 5.0%) 2 103 16350 9T21B1019G02
600 Volts 120/240 Volts 5 60 (+2,-2 2.5%) 107 16350 9T21B1025G02
600 Volts 120/240 Volts 7.5 60 (-2 5.0%) 2 147 16600 9T21B1020G02
600 Volts 120/240 Volts 10 60 (-2 4.9%) 2 198 19400 9T21B1021G02
600 Volts 120/240 Volts 15 60 No Taps 5 220 19500 9T21B9111
600 Volts 120/240 Volts 15 60 (-2 4.8%) 2 220 19500 9T21B9113
600 Volts 120/240 Volts 25 60 (-2 5.0%) 2 388 50500 9T21B9114
1See page 10-45 for wiring diagrams..

10-50 BuyLogTM Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Dry Type Transformers Section 10
Buck-Boost
Encapsulated
Autotransformers
For Bucking and Boosting Voltage

Wiring Diagram: Single-Phase


Application
For General Lighting and Power Service
Autotransformers are more economical than isolation transform-
ers designed to carry the same load. Within their voltage limita-
tions, they will perform the same function as transformers with
the exception of insulating two circuits. You can use these auto-
transformers to obtain 120 Volts from a 240 Volt circuit, to derive
a neutral on a 240 Volt, two-wire circuit, or to balance a 120/240
Volt, three-wire circuit. They also may be used in banks on Wiring Diagram: Three-Phase
polyphase circuits. See footnotes below.

For Bucking or Boosting Voltage of Single-Phase Indoor/Outdoor Type QB 60 Hz UL Listed CSA Certified1
Approx. Net Frame Product
Input Voltage Output Voltage kVA2 Height (in) Width (in) Depth (in) Weight (Lbs.) Size Number
240/120 Volts 120 or 240/120 Volts 0.5 7.38 6.13 4.25 10 8175 9T51B0136
(Three-Wire)
240/120 Volts 120 or 240/120 Volts 0.75 8.38 6.88 4.88 16 10200 9T51B0137
(Three-Wire)
240/120 Volts 120 or 240/120 Volts 1 8.38 6.88 4.88 16 10200 9T51B0138
(Three-Wire)
240/120 Volts 120 or 240/120 Volts 1.5 9.63 7.88 5.5 25 12200 9T51B0139
(Three-Wire)
240/120 Volts 120 or 240/120 Volts 2 9.63 7.88 5.5 25 12225 9T51B0140
(Three-Wire)
240/120 Volts 120 or 240/120 Volts) 3 11.13 9.38 6.75 40 14200 9T51B0141
(Three-Wire)
240/120 Volts 120 or 240/120 Volts 5 11.13 9.38 6.75 60 14400 9T51B0142
(Three-Wire)
1Through 3 kVA

For Bucking or Boosting Voltage of Single-Phase Indoor/Outdoor Type QMS 60 Hz UL Listed CSA Certified
Approx. Net Frame Product
Input Voltage Output Voltage kVA2 Height (in) Width (in) Depth (in) Weight (Lbs.) Size Number
240/120 Volts 120 or 240/120 Volts 10 14.50 10.62 11.00 103 16350 9T21B4553G02
(Three-Wire)
240/120 Volts 120 or 240/120 Volts 15 17.06 10.62 11.00 147 16600 9T21B9201
(Three-Wire)
240/120 Volts 120 or 240/120 Volts 25 17.06 12.50 12.50 220 19500 9T21B9202
(Three-Wire)
2kVA output at 120 Volts, two-wire, or allowable unbalance at 240/120 Volts, three-wire.

For Boosting Voltage of Three-Phase Indoor/Outdoor Type QB 60 Hz UL Listed


Approx. Net Frame Product
Input Voltage Output Voltage kVA3 Height (in) Width (in) Depth (in) Weight (Lbs.) Size Number
208Y/120 Volts 230/133 Volts 6 7.38 6.13 4.25 10 8175 9T51B0143
208Y/120 Volts 230/133 Volts 9 8.38 6.88 4.88 16 10200 9T51B0144
208Y/120 Volts 230/133 Volts 15 8.38 6.88 4.88 20 10225 9T51B0145
208Y/120 Volts 230/133 Volts 30 9.63 7.88 5.50 30 12275 9T51B0146
208Y/120 Volts 230/133 Volts 45 11.13 9.38 6.75 40 14200 9T51B0147
208Y/120 Volts 230/133 Volts 75 11.13 9.38 6.75 60 14400 9T51B0148
208Y/120 Volts 240/120 Volts 6 7.38 6.13 4.25 10 8175 9T51B0150
208Y/120 Volts 240/120 Volts 15 9.63 7.88 5.50 25 12200 9T51B0152
208Y/120 Volts 240/120 Volts 30 11.13 9.38 6.75 40 14200 9T51B0153
208Y/120 Volts 240/120 Volts 45 11.13 9.38 6.75 45 14250 9T51B0154
3Bank of three single-phase autotransformers to be connected wye. Price is for one single unit. Dimensions and weights are for each unit in bank. Each single autotrans-
former is rated 1/3 of the bank kVA rating. Order three single-phase transformers for each three-phase bank.

Conversion Chart
Decimal Fraction
.13 1/8
.38 3/8
.63 5/8
.88 7/8

Rev. 11/13 www.geindustrial.com BuyLogTM Catalog 10-51


Data subject to change
without notice
Dry Type Transformers Section 10
Buck-Boost
Encapsulated
For Bucking and Boosting Voltage

Product Description
Buck boost transformers are small, single-phase, dry type distri-
bution transformers designed and shipped as insulating/isolating
transformers. They have a dual voltage primary and a dual volt-
age secondary. These transformers can be connected for a wide
range of voltage combinations. The most common use is to buck
(lower) or boost (raise) the supply voltage a small amount, usual-
ly 5 to 27%. Buck boost transformers comply with NEC Article
210-9, Exception 1, when field connected as an autotransformer.
GE bucking and boosting transformers provide an economical
and convenient means for bucking or boosting voltage, usually
no more than 20% on single- and three-phase circuits. They are
compact, relatively light in weight, and can be easily installed for
indoor or outdoor service.
Buck-boost transformers are employed primarily for boosting
single-and three-phase circuits by connecting them as auto-
Indoor/Outdoor Type QB Transformer; Single-Phase
transformers. When connected as an autotransformer, only the
low-voltage, high-current capacity secondary windings are
required to carry the load. Because this load is only transformed
over a small change in voltage, the buck-boost transformer can
handle loads many times its nameplate kVA rating.
The transformers with series-multiple 12/24, 24/48, or 16/32 Volt
secondary windings are suitable for a wide variety of applica-
tions. Two or more units can be used in various combinations to
obtain many other special voltages. (For fluctuating voltage con-
ditions, refer to Power Conditioning Equipment Products section
starting on page 10-36).
Wiring Diagram for Low Voltage Loads
Advantages
Efficient insulating materials permit compact size and
light weight Qualified to the seismic requirements of IEEE-693-1997 and
Dual voltage primary and dual voltage secondary for IBC-2003
maximum versatility ABS (American Bureau of Shipping) Type Approved
Large, front-accessible wiring compartment permits fast,
easy wiring Applications
Convenient conduit knockouts located on side, bottom and
International voltage adaptation
back of wiring compartment
Commercial and industrial air conditioning
GE Buck-Boost Transformer Selector makes selection fast
Heating systems
and easy
Induction motors
Many GE buck-boost transformers fit competitor mounting
Voltage line drop correction
footprints
Landscape lighting
Indoor or outdoor service
Low-voltage lighting
Key Features Marine and Offshore - ABS Classed Vessels
Convenient and least expensive method of matching line
Efficient operation of electrical equipment requires that line volt-
voltage with equipment voltage
age be at or near the nameplate rating of the equipment. In
More efficient than equivalent isolation transformers
order to match available line voltage (whether it be too high or
Ability to handle loads up to 20 times nameplate rating when
low) with equipment voltage, buck-boost transformers provide
connected as an autotransformer
the most convenient and least expensive method.
Ideal for changing line voltages by small amounts
Primary voltages include 120V, 240V and 480V Do not use buck-boost transformers to solve a fluctuating voltage
Secondary voltages include 12V, 16V, 24V, 32V, 48V problem. They should be used to compensate for high- or low-
UL and cUL Listed voltage conditions only when the available line voltage is
reasonably constant.

10-52 BuyLogTM Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Dry Type Transformers Section 10
Buck-Boost
Encapsulated
For Bucking and Boosting Voltage

Single-Phase Indoor/Outdoor Type QB 60 Hz UL Listed C-UL Listed


Approx. Net Frame Product
Input Voltage Output Voltage kVA Height (in) Width (in) Depth (in) Weight (Lbs.) Size Number
120/240 Volts 12/24 Volts 0.05 6.38 5.12 3.25 6 6100 9T51B0102
120/240 Volts 12/24 Volts 0.075 6.38 5.12 3.25 6 6200 9T51B0103
120/240 Volts 12/24 Volts 0.1 6.38 5.12 3.25 6 6200 9T51B0104
120/240 Volts 12/24 Volts 0.15 7.38 6.12 4.25 10 8175 9T51B0105
120/240 Volts 12/24 Volts 0.25 7.38 6.12 4.25 10 8175 9T51B0107
120/240 Volts 12/24 Volts 0.5 8.38 6.88 4.88 20 10225 9T51B0108
120/240 Volts 12/24 Volts 0.75 9.62 7.88 5.50 25 12200 9T51B0109
120/240 Volts 12/24 Volts 1 9.62 7.88 5.50 25 12225 9T51B0110
120/240 Volts 12/24 Volts 1.5 11.12 9.38 6.72 40 14200 9T51B0111
120/240 Volts 12/24 Volts 2 11.12 9.38 6.72 50 14300 9T51B0112
120/240 Volts 12/24 Volts 3 9.38 6.72 55 14350 9T51B0113
120/240 Volts 16/32 Volts 0.05 6.38 5.12 3.25 6 6100 9T51B0122
120/240 Volts 16/32 Volts 0.075 6.38 5.12 3.25 6 6200 9T51B0123
120/240 Volts 16/32 Volts 0.1 6.38 5.12 3.25 6 6200 9T51B0124
120/240 Volts 16/32 Volts 0.15 7.38 6.12 4.25 10 8175 9T51B0125
120/240 Volts 16/32 Volts 0.25 7.38 6.12 4.25 10 8175 9T51B0127
120/240 Volts 16/32 Volts 0.5 8.38 6.88 4.88 20 10225 9T51B0128
120/240 Volts 16/32 Volts 0.75 9.62 7.88 5.50 25 12200 9T51B0129
120/240 Volts 16/32 Volts 1 9.62 7.88 5.50 30 12300 9T51B0130
120/240 Volts 16/32 Volts 1.5 11.12 9.38 6.72 40 14200 9T51B0131
120/240 Volts 16/32 Volts 2 11.12 9.38 6.72 50 14300 9T51B0132
120/240 Volts 16/32 Volts 3 9.38 6.72 55 14350 9T51B0133
240/480 Volts 24/48 Volts 0.05 6.38 5.12 3.25 6 6100 9T51B0202
240/480 Volts 24/48 Volts 0.075 6.38 5.12 3.25 6 6200 9T51B0203
240/480 Volts 24/48 Volts 0.1 6.38 5.12 3.25 6 6200 9T51B0204
240/480 Volts 24/48 Volts 0.15 7.38 6.12 4.25 10 8175 9T51B0205
240/480 Volts 24/48 Volts 0.25 7.38 6.12 4.25 10 8175 9T51B0207
240/480 Volts 24/48 Volts 0.5 8.38 6.88 4.88 20 10225 9T51B0208
240/480 Volts 24/48 Volts 0.75 9.62 7.88 5.50 25 12200 9T51B0209
240/480 Volts 24/48 Volts 1 9.62 7.88 5.50 30 12275 9T51B0210
240/480 Volts 24/48 Volts 1.5 11.12 9.38 6.72 40 14200 9T51B0211
240/480 Volts 24/48 Volts 2 11.12 9.38 6.72 50 14300 9T51B0212
240/480 Volts 24/48 Volts 3 11.12 9.38 6.72 55 14350 9T51B0213

Single-Phase Indoor/Outdoor Type QMS 60 Hz UL Listed C-UL Listed


Approx. Net Frame Product
Input Voltage Output Voltage kVA Height (in) Width (in) Depth (in) Weight (Lbs.) Size Number
120/240 Volts 12/24 Volts 5 14.5 10.62 11 103 16350 9T21B1037G02
120/240 Volts 16/32 Volts 5 14.5 10.62 11 115 16400 9T21B1040G02

Single-Phase Indoor/Outdoor Type QMS 50 Hz UL Listed C-UL Listed


Approx. Net Frame Product
Input Voltage Output Voltage kVA Height (in) Width (in) Depth (in) Weight (Lbs.) Size Number
120/240 Volts 12/24 Volts 5 14.5 10.62 11 115 16400 9T21B1061G02
120/240 Volts 16/32 Volts 5 14.5 10.62 11 127 16450 9T21B1064G02

NOTE: In addition to bucking or boosting low circuit voltages to related value, these transformers can be used as two winding transformers to supply the rated nameplate
low voltages, 12 to 48 Volts, two-wire or 12/24 to 24/48 Volts, three-wire. Also available in 50/60 Hz ratings.

Rev. 11/13 www.geindustrial.com BuyLogTM Catalog 10-53


Data subject to change
without notice
Dry Type Transformers Section 10
Buck-Boost Selection Tables
Encapsulated
For Bucking and Boosting Voltage

5-Step Selection
The tables on these pages greatly facilitate buck-boost trans- 4. Once you have established this point, read across to the far
former selection. Simply follow these five easy steps: left column for the exact GE buck-boost model number for
your application. For example, the 230 Volt table under the
1. Refer to the table having the same output voltage as the 208 column for a 2 kVA air conditioner, read across from 2.4
equipment you want to operate. For example, if you are (next higher kVA rating) and the model number is 9T51B0107.
installing a 230 Volt single-phase air conditioner, use the 5. Connect the buck-boost transformer you have selected per
230 Volt table. the connection diagram specified at the bottom of the avail-
2. Different available line voltages are listed across the top of able line voltage column you used. For example, if you used
each table. Select the line voltage column closest to your the 208 column, you would connect the buck-boost trans-
actual supply. If your available line voltage is exactly midway former per connection diagram A. Thats all there is to it! The
between two listed voltage levels, you may use either voltage transformer youve selected will meet your exact requirements
column. For example, in the 230 Volt table, if you have 212 when connected in the specified manner.
available, use either the 208 or the 216 column.
The formula for calculating single-phase kVA is:
3. Read down the available line voltage column until you reach
the rated load kVA of the equipment you want to operate or Load Voltage Full Load Amps
the next higher kVA rating. For example, in the 230 Volt table 1000
under the 208 available line voltage column, you want to oper-
ate an air conditioner rated 2 kVA. Since 2 kVA is not listed as The formula for calculating three-phase kVA is:
such, you must read down to the next higher value or 2.4 kVA. 1.732 Load Voltage Load Amps
1000

Table 1
230 Volts Output, 60 Hertz, Single-Phase
Available Line Voltage
192 203 208 216 219 242 245 353 261 276
Product Number Load kVA1
9T51B0102 0.480 0.960 1.0 0.530
9T51B0122 0.360 0.720 0.770 0.410
9T51B0202 0.240 0.288
9T51B0103 0.720 1.5 1.6 0.800
9T51B0123 0.540 1.1 1.2 0.620
9T51B0203 0.359 0.431
9T51B0104 0.960 2.0 2.1 1.1
9T51B0124 0.720 1.5 1.6 0.820
9T51B0204 0.479 0.575
9T51B0105 1.5 2.9 3.1 1.6
9T51B0125 1.1 2.2 2.3 1.3
9T51B0205 0.719 0.863
9T51B0107 2.4 4.8 5.1 2.7
9T51B0127 1.8 3.6 3.9 2.1
9T51B0207 1.2 1.4
9T51B0108 4.8 9.6 10.1 5.3
9T51B0128 3.6 7.2 7.7 4.1
9T51B0208 2.4 2.9
9T51B0109 7.2 14.4 15.2 7.9
9T51B0129 5.4 10.8 11.5 6.2
9T51B0209 3.6 4.3
9T51B0110 9.6 19.2 20.2 10.6
9T51B0130 7.2 14.4 15.4 8.2
9T51B0210 4.8 5.7
9T51B0111 14.4 28.8 30.3 15.9
9T51B0131 10.8 21.6 23.0 12.3
9T51B0211 7.2 8.6
9T51B0112 19.1 38.4 40.4 21.1
9T51B0132 14.4 28.8 30.7 16.4
9T51B0212 9.6 11.5
9T51B0113 28.7 57.5 60.5 31.7
9T51B0133 21.6 43.2 46.0 24.5
9T51B0213 14.4 17.3
9T21B1037G02 47.8 95.9 100.9 52.7
9T21B1040G02 36.0 72.0 77.0 40.8
Connection Diagram C A A B B B B A A C
Page 10-61
1The load kVA is the maximum load at voltages shown when transformers are connected as autotransformers according to the diagram referenced.

10-54 BuyLogTM Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Dry Type Transformers Section 10
Buck-Boost Selection Tables
Encapsulated
For Bucking and Boosting Voltage

Table 2
240 Volts Output, 60 Hertz, Single-Phase
Available Line Voltage
200 212 218 225 229 252 256 264 272 288
Product Number Load kVA1
9T51B0102 0.500 1.0 1.1 0.6
9T51B0122 0.380 0.750 0.800 0.430
9T51B0202 0.250 0.300
9T51B0103 0.750 1.5 1.6 0.825
9T51B0123 0.570 1.2 1.2 0.640
9T51B0203 0.375 0.391
9T51B0104 1.0 2.0 2.1 1.1
9T51B0124 0.750 1.5 1.6 0.850
9T51B0204 0.500 0.522
9T51B0105 1.5 3.0 3.2 1.7
9T51B0125 1.2 2.3 2.4 1.3
9T51B0205 0.750 0.782
9T51B0107 2.5 5.0 5.3 2.8
9T51B0127 1.9 3.8 4.0 2.2
9T51B0207 1.3 1.4
9T51B0108 5.0 10.0 10.5 5.5
9T51B0128 3.8 7.5 8.0 4.3
9T51B0208 2.5 2.6
9T51B0109 7.5 15.0 15.8 8.3
9T51B0129 5.7 11.3 12.0 6.4
9T51B0209 3.8 4.0
9T51B0110 10.0 20.0 21.0 11.0
9T51B0130 7.5 15.0 16.0 8.5
9T51B0210 5.0 5.2
9T51B0111 15.0 30.0 31.5 16.5
9T51B0131 11.3 22.5 24.0 12.8
9T51B0211 7.5 7.8
9T51B0112 20.0 40.0 42.6 22.0
9T51B0132 15.0 30.0 32.0 17.0
9T51B0212 10.0 10.4
9T51B0113 30.0 60.0 63.0 33.0
9T51B0133 22.5 45.0 48.0 25.5
9T51B0213 15.0 15.6
9T21B1037G02 50.0 100.0 105.0 55.0
9T21B1040G02 37.5 75.0 80.0 42.5
Connection Diagram C A A B B B B A A C
Page 10-61
1The load kVA is the maximum load at voltages shown when transformers are connected as autotransformers according to the diagram referenced.

Rev. 11/13 www.geindustrial.com BuyLogTM Catalog 10-55


Data subject to change
without notice
Dry Type Transformers Section 10
Buck-Boost Selection Tables
Encapsulated
For Bucking and Boosting Voltage

Table 3
115 Volts Output, 60 Hertz, Single-Phase
Available Line Voltage
91 96 101 105 127 130 138 146
Product Number Load kVA1
9T51B0102 0.240 0.480 0.539 0.290
9T51B0122 0.180 0.360 0.410 0.230
9T51B0103 0.360 0.720 0.800 0.440
9T51B0123 0.270 0.540 0.610 0.350
9T51B0104 0.480 0.960 1.1 0.580
9T51B0124 0.360 0.720 0.820 0.460
9T51B0105 0.720 1.5 1.6 0.870
9T51B0125 0.540 1.1 1.3 0.690
9T51B0107 1.2 2.4 2.7 1.5
9T51B0127 0.900 1.8 2.1 1.2
9T51B0108 2.4 4.8 5.3 2.9
9T51B0128 1.8 3.6 4.1 2.3
9T51B0109 3.6 7.2 8.0 4.4
9T51B0129 2.7 5.4 6.1 3.5
9T51B0110 4.8 9.6 10.6 5.8
9T51B0130 3.6 7.2 8.2 4.6
9T51B0111 7.2 14.4 15.9 8.6
9T51B0131 5.4 10.8 12.2 6.9
9T51B0112 9.6 19.2 21.2 11.5
9T51B0132 7.2 14.4 16.3 9.2
9T51B0113 14.4 28.8 31.8 17.3
9T51B0133 10.8 21.6 24.4 13.7
9T21B1061G02 24.0 48.0 53.0 28.8
9T21B1037G02 24.0 48.0 53.0 28.8
9T21B1064G02 18.0 36.0 41.0 22.9
9T21B1040G02 18.0 36.0 41.0 22.9
Connection Diagram C C D D D D C C
Page 10-61
1The load kVA is the maximum load at voltages shown when transformers are connected as autotransformers according to the diagram referenced.

Table 4
120 Volts Output, 60 Hertz, Single-Phase
Available Line Voltage
95 100 106 109 132 136 144 152
Product Number Load kVA1
9T51B0102 0.250 0.500 0.550 0.300
9T51B0122 0.190 0.380 0.430 0.240
9T51B0103 0.380 0.750 0.830 0.450
9T51B0123 0.290 0.570 0.640 0.360
9T51B0104 0.500 1.0 1.1 0.600
9T51B0124 0.380 0.750 0.850 0.480
9T51B0105 0.750 1.5 1.7 0.900
9T51B0125 0.570 1.2 1.3 0.720
9T51B0107 1.3 2.5 2.8 1.5
9T51B0127 0.940 1.9 2.2 1.2
9T51B0108 2.5 5.0 5.5 3.0
9T51B0128 1.9 3.8 4.3 2.4
9T51B0109 3.8 7.5 8.3 4.5
9T51B0129 2.9 5.7 6.4 3.6
9T51B0110 5.0 10.0 11.0 6.0
9T51B0130 3.8 7.5 8.5 4.8
9T51B0111 7.5 15.0 16.5 9.0
9T51B0131 5.7 11.3 12.8 7.2
9T51B0112 10.0 20.0 22.0 12.0
9T51B0132 7.5 15.0 17.0 9.5
9T51B0113 15.0 30.0 33.0 18.0
9T51B0133 11.3 22.5 25.5 14.3
9T21B1061G02 25.0 50.0 55.0 30.0
9T21B1037G02 25.0 50.0 55.0 30.0
9T21B1064G02 18.8 38.0 43.0 23.8
9T21B1040G02 18.8 38.0 43.0 23.8
Connection Diagram C C D D D D C C
Page 10-61
1The load kVA is the maximum load at voltages shown when transformers are connected as autotransformers according to the diagram referenced.

10-56 BuyLogTM Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Dry Type Transformers Section 10
Buck-Boost Selection Tables
Encapsulated
For Bucking and Boosting Voltage

Table 5
230 Volts, 3-Wire Output, 60 Hertz, Three-Phase 2
Available Line Voltage
181Y/105 192Y/111 203Y/117 208Y/120 277Y/160
Quantity Required Product
Per Bank Number Load kVA1
3 9T51B0102 0.830 1.7
3 9T51B0122 0.620 1.3
3 9T51B0202 0.480
3 9T51B0103 1.2 2.5
3 9T51B0123 0.930 1.9
3 9T51B0203 0.720
3 9T51B0104 1.7 3.4
3 9T51B0124 1.2 2.5
3 9T51B0204 0.960
3 9T51B0105 2.5 5.0
3 9T51B0125 1.9 3.7
3 9T51B0205 1.44
3 9T51B0107 4.2 8.3
3 9T51B0127 3.1 6.2
3 9T51B0207 2.4
3 9T51B0108 8.3 16.6
3 9T51B0128 6.2 12.5
3 9T51B0208 4.8
3 9T51B0109 12.5 25.0
3 9T51B0129 9.3 18.7
3 9T51B0209 7.2
3 9T51B0110 16.6 33.2
3 9T51B0130 12.5 25.0
3 9T51B0210 9.6
3 9T51B0111 25.0 50.0
3 9T51B0131 18.7 37.0
3 9T51B0211 14.4
3 9T51B0112 33.0 66.0
3 9T51B0132 25.0 50.0
3 9T51B0212 19.2
3 9T51B0113 50.0 100.0
3 9T51B0133 37.5 75.0
3 9T51B0213 28.8
3 9T21B1037G02 83.0 167.0
3 9T21B1040G02 62.0 125.0
Connection Diagram F F G G F
Page 10-61
1The load kVA is the maximum load at voltages shown when transformers are connected as autotransformers according to the diagram referenced.
2See Caution page 10-59, footnote 1.

Rev. 11/13 www.geindustrial.com BuyLogTM Catalog 10-57


Data subject to change
without notice
Dry Type Transformers Section 10
Buck-Boost Selection Tables
Encapsulated
For Bucking and Boosting Voltage

Table 6
240 Volts, 3-Wire Output, 60 Hertz, Three-Phase 2
Available Line Voltage
189Y/109 200Y/115 208Y/1203 218Y/126 288Y/166
212Y/122
Quantity Required Product
Per Bank Number Load kVA1
3 9T51B0102 0.870 1.7
3 9T51B0122 0.650 1.3
3 9T51B0202 0.500
3 9T51B0103 1.3 2.6
3 9T51B0123 0.970 2.0
3 9T51B0203 0.750
3 9T51B0104 1.7 3.5
3 9T51B0124 1.3 2.6
3 9T51B0204 1.0
3 9T51B0105 2.6 5.2
3 9T51B0125 2.0 3.9
3 9T51B0205 1.5
3 9T51B0107 4.3 8.7
3 9T51B0127 3.2 6.5
3 9T51B0207 2.5
3 9T51B0108 8.7 17.3
3 9T51B0128 6.5 13.0
3 9T51B0208 5.0
3 9T51B0109 13.0 26.0
3 9T51B0129 9.7 19.5
3 9T51B0209 7.5
3 9T51B0110 17.3 34.6
3 9T51B0130 13.0 26.0
3 9T51B0210 10.0
3 9T51B0111 26.0 52.0
3 9T51B0131 19.5 39.0
3 9T51B0211 15.0
3 9T51B0112 35.0 70.0
3 9T51B0132 26.0 52.0
3 9T51B0212 20.0
3 9T51B0113 52.0 104.0
3 9T51B0133 39.0 78.0
3 9T51B0213 30.0
3 9T21B1037G02 87.0 173.0
3 9T21B1040G02 65.0 130.0
Connection Diagram F F G G F
Page 10-61
1The load kVA is the maximum load at voltages shown when transformers are connected as autotransformers according to the diagram referenced.
2See Caution page 10-59, footnote 1.
3When 208Y/120 Volts is the available line voltage, the 212Y/122 column may be used to obtain 236 Volts which should be satisfactory for most applications.

10-58 BuyLogTM Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Dry Type Transformers Section 10
Buck-Boost Selection Tables
Encapsulated
For Bucking and Boosting Voltage

Table 7
460 Volts, 3-Wire Output, 60 Hertz, Three-Phase 1
Available Line Voltage 3- or 4-Wire
385 406 418 432 438
Quantity Required Product
Per Bank Number Load kVA2
3 9T51B0102 1.66 3.32
3 9T51B0122 1.25 2.49
3 9T51B0202 0.830
3 9T51B0103 2.48 4.96
3 9T51B0123 1.87 3.73
3 9T51B0203 1.2
3 9T51B0104 3.31 6.62
3 9T51B0124 2.49 4.97
3 9T51B0204 1.7
3 9T51B0105 4.97 9.94
3 9T51B0125 3.73 3.9
3 9T51B0205 2.5
3 9T51B0107 8.28 16.6
3 9T51B0127 6.22 6.5
3 9T51B0207 4.2
3 9T51B0108 16.6 33.2
3 9T51B0128 12.5 13.0
3 9T51B0208 8.3
3 9T51B0109 24.8 59.6
3 9T51B0129 18.7 19.5
3 9T51B0209 12.5
3 9T51B0110 33.1 66.2
3 9T51B0130 24.9 26.0
3 9T51B0210 16.6
3 9T51B0111 49.7 99.4
3 9T51B0131 37.3 39.0
3 9T51B0211 24.9
3 9T51B0112 66.3 133.0
3 9T51B0132 49.7 52.0
3 9T51B0212 33.2
3 9T51B0113 99.3 198.6
3 9T51B0133 74.6 78.0
3 9T51B0213 49.8
3 9T21B1037G02 166.0 322.0
3 9T21B1040G02 125.0 130.0
Connection Diagram F H H I I
Page 10-61
1Caution: If input is 3-wire Delta or 4-wire midtapped Delta, the neutral established from the bank of buck-boost transformers must be insulated and isolated
from the input power neutral and/or ground.
2The load kVA is the maximum load at voltages shown when transformers are connected as autotransformers according to the diagram referenced.

Rev. 11/13 www.geindustrial.com BuyLogTM Catalog 10-59


Data subject to change
without notice
Dry Type Transformers Section 10
Buck-Boost Selection Tables
Encapsulated
For Bucking and Boosting Voltage

Table 8
480 Volts, 3-Wire Output, 60 Hertz, Three-Phase1
Available Line Voltage 3- or 4-Wire
400 424 436 450
Quantity Required Product
Per Bank Number Load kVA2
9T51B0102 1.74
3 9T51B0122 1.3 2.6
3 9T51B0202 0.866
3 9T51B0103 2.6
3 9T51B0123 1.95 3.9
3 9T51B0203 1.3
3 9T51B0104 3.5
3 9T51B0124 2.6 5.2
3 9T51B0204 1.7
3 9T51B0105 5.2
3 9T51B0125 3.9 7.8
3 9T51B0205 2.6
3 9T51B0107 8.7
3 9T51B0127 6.3 13.0
3 9T51B0207 4.3
3 9T51B0108 17.4
3 9T51B0128 13.0 26.0
3 9T51B0208 8.7
3 9T51B0109 26.0
3 9T51B0129 19.5 39.0
3 9T51B0209 13.0
3 9T51B0110 35.0
3 9T51B0130 26.0 52.0
3 9T51B0210 17.3
3 9T51B0111 52.2
3 9T51B0131 39.0 78.0
3 9T51B0211 26.0
3 9T51B0112 69.0
3 9T51B0132 52.0 104.0
3 9T51B0212 34.6
3 9T51B0113 104.0
3 9T51B0133 78.0 156.0
3 9T51B0213 51.9
3 9T21B1037G02 174.0
3 9T21B1040G02 130.0 260.0
Connection Diagram F H H I
Page 10-61

Table 9
208 Volts, 3-Wire, 60 Hertz, Three-Phase1
Available Line Voltage 3- or 4-Wire
218 222 229 236
Quantity Required Product
Per Bank Number Load kVA2
2 9T51B0102 1.6 0.800
2 9T51B0122 1.2 0.640
2 9T51B0103 2.3 1.2
2 9T51B0123 1.8 0.960
2 9T51B0104 3.2 1.6
2 9T51B0124 2.4 1.3
2 9T51B0105 4.7 2.5
2 9T51B0125 3.6 1.9
2 9T51B0107 7.8 4.1
2 9T51B0127 6.0 3.2
2 9T51B0108 16 8.0
2 9T51B0128 12.0 6.4
2 9T51B0109 23.6 12.4
2 9T51B0129 18.0 9.6
2 9T51B0110 31.5 16.5
2 9T51B0130 24.0 12.7
2 9T51B0111 47.5 24.8
2 9T51B0131 36.0 19.1
2 9T51B0112 63.0 33.0
2 9T51B0132 48.0 25.6
2 9T51B0113 94 49.6
2 9T51B0133 72.0 38.3
Connection Diagram J J Z Z
Page 10-61
1Caution: If input is 3-wire Delta or 4-wire midtapped Delta, the neutral established from the bank of buck-boost transformers must be insulated and isolated
from the input power neutral and/or ground.
2The load kVA is the maximum load at voltages shown when transformers are connected as autotransformers according to the diagram referenced.

10-60 BuyLogTM Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Dry Type Transformers Section 10
Buck-Boost Connection Diagrams
Encapsulated
For Bucking and Boosting Voltage

Connection Diagrams

Rev. 11/13 www.geindustrial.com BuyLogTM Catalog 10-61


Data subject to change
without notice
Dry Type Transformers Section 10
Open Core and Coil Transformers
Machine Tool and Control Power
Product Description
Core and coil transformers for machine tools are used to provide
voltage to control devices in applications where regulation and
minimum space are important. Welded cores provide the highest
quality electrical performance and quiet operation.
Standards: Type IP transformers conform to NEMA ST20
Listings: UL listed under UL-5085, File E2739
CSA Certified under C22.2, Number 66, File 3272
Insulation Classes: 150VA and below: 105C insulation class,
55C Rise
200VA and above: 185C (NEMA)
180C (UL) insulation class, 115C Rise
Frequency: 60 Hz standard; 50 Hz optional.
Voltage Regulation: All designs 2.0 kVA and below are compen-
sated for voltage drop. Compensation ranges from 10% in the
smallest rating to 3% for the largest. All machine tool designs
meet or exceed NMTBA regulation requirements.
Core and Coil Transformer
Series-Multiple Secondary Connections: Transformers with
Leads Out Connection
120/240 V secondaries (series-multiple) may be connected for
120 V, 240 V or 240/120 V three-wire. Jumpers are provided.
Overcurrent Protection: Type IP transformers are low impedance Advantages
transformers that require overcurrent protection for most Finger-safe terminals offer added protection and safety
applications. They provide for optional integral primary and/or Pressure plate terminals ensure secure connections
secondary fusing. Wide variety of fusing options
Mounting Dimensions: Type IP transformers are lightweight,
small, and designed for minimum mounting dimensions. Many
units will fit competitors mounting footprints. Key FeaturesTerminal Board Connection
Rugged, high-impact plastic terminal board
Full head #8 brass screws assure quick, easy terminations with
maximum connection integrity
Copper windings
Flexible design allows input or output voltage to match any
application
CUL, CE, UL approvals
Available fuse-blocks offer simple, low-cost fusing

Core and Coil Transformer


Terminal Board Connection

10-62 BuyLogTM Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Page Updated 09 / 2016

Dry Type Transformers Section 10


Open Core and Coil Transformers
Machine Tool Applications
Single-Phase, Fully-encapsulated Design

60 Hz Terminal Board Connection


Input Output Wiring Approx. Net Frame Product
Voltage Voltage kVA Diagram No.1 Weight (Lbs) Size Number
220x440, 230x460,240x480 Volts 110, 115, 120 Volts 0.05 1 2.4 6100 9T58K0042
220x440, 230x460,240x480 Volts 110, 115, 120 Volts 0.08 1 2.8 6125 9T58K0043
220x440, 230x460,240x480 Volts 110, 115, 120 Volts 0.10 1 3.6 8100 9T58K0044
220x440, 230x460,240x480 Volts 110, 115, 120 Volts 0.15 1 5.1 8150 9T58K0045
220x440, 230x460,240x480 Volts 110, 115, 120 Volts 0.20 1 5.8 8175 9T58K0046
220x440, 230x460,240x480 Volts 110, 115, 120 Volts 0.25 1 6.5 8200 9T58K0047
220x440, 230x460,240x480 Volts 110, 115, 120 Volts 0.30 1 7.6 8250 9T58K0048
220x440, 230x460,240x480 Volts 110, 115, 120 Volts 0.38 1 7.6 8250 9T58K0049
220x440, 230x460,240x480 Volts 110, 115, 120 Volts 0.50 1 10.7 10225 9T58K0050
220x440, 230x460,240x480 Volts 110, 115, 120 Volts 0.75 1 12 12225 9T58K0051
220x440, 230x460,240x480 Volts 110, 115, 120 Volts 1 1 16.1 12300 9T58K0052
220x440, 230x460,240x480 Volts 110, 115, 120 Volts 2 1 26.7 14225 9T58K0053
220x440, 230x460,240x480 Volts 110, 115, 120 Volts 2 1 32.7 14300 9T58K0054
220x440, 230x460,240x480 Volts 110, 115, 120 Volts 3 1 47.4 14475 9T58K0055

50/60 Hz Terminal Board Connection


Input Output Wiring Approx. Net Frame Product
Voltage Voltage kVA Diagram No.1 Weight (Lbs) Size Number
230/460/575 Volts 115/95 Volts 0.05 2 3.1 6150 9T58K0062
230/460/575 Volts 115/95 Volts 0.08 2 3.6 8100 9T58K0063
230/460/575 Volts 115/95 Volts 0.10 2 5.1 8150 9T58K0064
230/460/575 Volts 115/95 Volts 0.15 2 6.5 8200 9T58K0065
230/460/575 Volts 115/95 Volts 0.20 2 6.5 8200 9T58K0066
230/460/575 Volts 115/95 Volts 0.25 2 7.6 8250 9T58K0067
230/460/575 Volts 115/95 Volts 0.30 2 10.7 10225 9T58K0068
230/460/575 Volts 115/95 Volts 0.38 2 10.7 10225 9T58K0069
230/460/575 Volts 115/95 Volts 0.50 2 10.7 10225 9T58K0070
230/460/575 Volts 115/95 Volts 0.75 2 16.1 12300 9T58K0071
230/460/575 Volts 115/95 Volts 1 2 26.7 14225 9T58K0072
230/460/575 Volts 115/95 Volts 1.5 2 32.7 14300 9T58K0073
230/460/575 Volts 115/95 Volts 2 2 47.4 14475 9T58K0074
208/277/380 Volts 115/95 Volts 0.05 3 3.1 6150 9T58K0082
208/277/380 Volts 115/95 Volts 0.08 3 3.6 8100 9T58K0083
208/277/380 Volts 115/95 Volts 0.10 3 5.1 8150 9T58K0084
208/277/380 Volts 115/95 Volts 0.15 3 6.5 8200 9T58K0085
208/277/380 Volts 115/95 Volts 0.20 3 6.5 8200 9T58K0086
208/277/380 Volts 115/95 Volts 0.25 3 7.6 8250 9T58K0087
208/277/380 Volts 115/95 Volts 0.30 3 10.7 10225 9T58K0088
208/277/380 Volts 115/95 Volts 0.38 3 10.7 10225 9T58K0089
208/277/380 Volts 115/95 Volts 0.50 3 10.7 10225 9T58K0090
208/277/380 Volts 115/95 Volts 0.75 3 16.1 12300 9T58K0091
208/277/380 Volts 115/95 Volts 1 3 26.7 14225 9T58K0092
208/277/380 Volts 115/95 Volts 1.5 3 32.7 14300 9T58K0093
208/277/380 Volts 115/95 Volts 2 3 47.4 14475 9T58K0094
1See page 10-67 for wiring diagrams.

Factory- or Field-Installed Options


Secondary FusingFactory- or field-installed secondary fuse
clips are available. They are restricted to units with terminal strips
and a single secondary voltage or secondary with one tap.
Dual Primary and Secondary FusingFactory- or field-installed
dual primary and secondary fuse clips are available on all units.

Rev. 11/13 www.geindustrial.com BuyLogTM Catalog 10-63


Data subject to change
without notice
Page Updated 09 / 2016

Dry Type Transformers Section 10


Open Core and Coil Transformers
Control
Single-Phase, Fully-encapsulated Design

60 Hz Terminal Board Connection


Input Output Wiring Approx. Net Frame Product
Voltage Voltage kVA Diagram No.1 Weight (Lbs) Size Number
240x480 Volts 120/240 Volts 0.05 4 2.4 6100 9T58K2802
240x480 Volts 120/240 Volts 0.08 4 2.8 6125 9T58K2803
240x480 Volts 120/240 Volts 0.10 4 3.6 8100 9T58K2804
240x480 Volts 120/240 Volts 0.15 4 5.1 8150 9T58K2805
240x480 Volts 120/240 Volts 0.20 4 5.8 8175 9T58K2806
240x480 Volts 120/240 Volts 0.25 4 6.5 8200 9T58K2807
240x480 Volts 120/240 Volts 0.30 4 6.5 8200 9T58K2808
240x480 Volts 120/240 Volts 0.38 4 7.6 8250 9T58K2809
240x480 Volts 120/240 Volts 0.50 4 10.7 10225 9T58K2810
240x480 Volts 120/240 Volts 0.75 4 12 12225 9T58K2811
240x480 Volts 120/240 Volts 1 4 16.1 12300 9T58K2812
240x480 Volts 120/240 Volts 1.5 4 26.7 14225 9T58K2813
240x480 Volts 120/240 Volts 2 4 32.7 14300 9T58K2814
240x480 Volts 120/240 Volts 3 4 47.4 14475 9T58K2815
600 Volts 120/240 Volts 0.08 5 2.8 6125 9T58K2823
600 Volts 120/240 Volts 0.10 5 3.6 8100 9T58K2824
600 Volts 120/240 Volts 0.20 5 5.8 8175 9T58K2826
600 Volts 120/240 Volts 0.25 5 6.5 8200 9T58K2827
600 Volts 120/240 Volts 0.30 5 6.5 8200 9T58K2828
600 Volts 120/240 Volts 0.50 5 10.7 10225 9T58K2830
600 Volts 120/240 Volts 0.75 5 12 12225 9T58K2831
600 Volts 120/240 Volts 1 5 16.1 12300 9T58K2832
600 Volts 120/240 Volts 1.5 5 26.7 14225 9T58K2833
600 Volts 120/240 Volts 2 5 32.7 14300 9T58K2834
600 Volts 120/240 Volts 3 5 47.4 14475 9T58K2835
120x240 Volts 120/240 Volts 0.10 6 3.6 8100 9T58K2907
120x240 Volts 120/240 Volts 0.20 6 5.8 8175 9T58K2909
120x240 Volts 120/240 Volts 0.30 6 6.5 8200 9T58K2911
120x240 Volts 120/240 Volts 0.50 6 10.7 10225 9T58K2913
120x240 Volts 120/240 Volts 0.75 6 12 12225 9T58K2914
120x240 Volts 120/240 Volts 1 6 16.1 12300 9T58K2915
120x240 Volts 120/240 Volts 2 6 32.7 14300 9T58K2917
120x240 Volts 120/240 Volts 3 6 47.4 14475 9T58K2918

60 Hz Terminal Board Connection


Input Output Wiring Approx. Net Frame Product
Voltage Voltage kVA Diagram No.1 Weight (Lbs) Size Number
120 x 240 Volts 12/24 Volts 0.05 7 2.4 6100 9T58K2873
120 x 240 Volts 12/24 Volts 0.075 7 2.8 6125 9T58K2874
120 x 240 Volts 12/24 Volts 0.10 7 3.6 8100 9T58K2875
120 x 240 Volts 12/24 Volts 0.15 7 5.1 8150 9T58K2876
120 x 240 Volts 12/24 Volts 0.20 7 5.8 8175 9T58K2877
120 x 240 Volts 12/24 Volts 0.25 7 6.5 8200 9T58K2878
120 x 240 Volts 12/24 Volts 0.30 7 6.5 8200 9T58K2879
240 x 480 Volts 12/24 Volts 0.25 --- 6.5 8200 9T58K3024
240 x 480 Volts 12/24 Volts 0.05 --- 2.4 6100 9T58K3164
240 x 480 Volts 12/24 Volts 0.10 --- 3.6 8100 9T58K4132
240 x 480 Volts 12/24 Volts 0.15 --- 5.1 8150 9T58K4133
208 x 240 Volts 12/24 Volts 0.05 --- 2.4 6100 9T58K4050
208 x 240 Volts 12/24 Volts 0.10 --- 3.6 8100 9T58K4051
208 x 240 Volts 12/24 Volts 0.15 --- 5.1 8150 9T58K4052
208 x 240 Volts 12/24 Volts 0.25 --- 6.5 8200 9T58K4053

50/60 Hz Terminal Board Connection


Input Output Wiring Approx. Net Frame Product
Voltage Voltage kVA Diagram No.1 Weight (Lbs) Size Number
240 x 480 Volts 120/240 Volts 0.50 4 10.7 10225 9T58K2930
240 x 480 Volts 120/240 Volts 0.75 4 16.1 12300 9T58K2931
240 x 480 Volts 120/240 Volts 1 4 26.7 14225 9T58K2932
240 x 480 Volts 120/240 Volts 1.5 4 32.7 14300 9T58K2933
240 x 480 Volts 120/240 Volts 2 4 47.4 14475 9T58K2934
240 x 480 Volts 120/240 Volts 3 4 47.4 14475 9T58K2935
380/400/416 Volts 115/230 Volts 0.25 8 6.5 8200 9T58K2975
380/400/416 Volts 115/230 Volts 0.50 8 10.7 10225 9T58K2978
380/400/416 Volts 115/230 Volts 0.75 8 16.1 12300 9T58K2979
380/400/416 Volts 115/230 Volts 1 8 26.7 14225 9T58K2980
380/400/416 Volts 115/230 Volts 1.5 8 32.7 14300 9T58K2981
380/400/416 Volts 115/230 Volts 2 8 47.4 14475 9T58K2982
380/400/416 Volts 115/230 Volts 3 8 47.4 14475 9T58K2983
1See page 10-67 for wiring diagrams.
2Secondary fusing not available.

10-64 BuyLogTM Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Page Updated 09 / 2016

Dry Type Transformers Section 10


Open Core and Coil Transformers
Control
Single-Phase, Fully-encapsulated Design

60 Hz Leads Out Connection2


Input Output Wiring Approx. Net Frame Product
Voltage Voltage kVA Diagram No.1 Weight (Lbs) Size Number
120x240 Volts 12/24 Volts 0.05 7 2.4 6100 9T58K1873G07
120x240 Volts 12/24 Volts 0.075 7 2.8 6125 9T58K1874G07
120x240 Volts 12/24 Volts 0.10 7 3.6 8100 9T58K1875G07
120x240 Volts 12/24 Volts 0.15 7 5.1 8150 9T58K1876G07
120x240 Volts 12/24 Volts 0.20 7 5.8 8175 9T58K1877G07
120x240 Volts 12/24 Volts 0.25 7 6.5 8200 9T58K1878G07
120x240 Volts 12/24 Volts 0.30 7 6.5 8200 9T58K1879G07
120x240 Volts 12/24 Volts 0.50 7 10.7 10225 9T58K1881G07
120x240 Volts 12/24 Volts 0.75 7 12 12225 9T58K1882G07
120x240 Volts 12/24 Volts 1 7 26.7 14225 9T58K1883G07

60 Hz Leads Out Connection2


Input Output Wiring Approx. Net Frame Product
Voltage Voltage kVA Diagram No.1 Weight (Lbs) Size Number
240 x 480 Volts 120/240 Volts 0.05 4 2.4 6100 9T58K1802G07
240 x 480 Volts 120/240 Volts 0.075 4 2.8 6125 9T58K1803G07
240 x 480 Volts 120/240 Volts 0.10 4 3.6 8100 9T58K1804G07
240 x 480 Volts 120/240 Volts 0.15 4 5.1 8150 9T58K1805G07
240 x 480 Volts 120/240 Volts 0.20 4 5.8 8175 9T58K1806G07
240 x 480 Volts 120/240 Volts 0.25 4 6.5 8200 9T58K1807G07
240 x 480 Volts 120/240 Volts 0.30 4 6.5 8200 9T58K1808G07
240 x 480 Volts 120/240 Volts 0.375 4 7.6 8250 9T58K1809G07
240 x 480 Volts 120/240 Volts 0.50 4 10.7 10225 9T58K1810G07
240 x 480 Volts 120/240 Volts 0.75 4 12 12225 9T58K1811G07
240 x 480 Volts 120/240 Volts 1 4 16.1 12300 9T58K1812G07
240 x 480 Volts 120/240 Volts 1.5 4 26.7 14225 9T58K1813G07
240 x 480 Volts 120/240 Volts 2 4 32.7 14300 9T58K1814G07
240 x 480 Volts 120/240 Volts 3 4 47.4 14475 9T58K1815G07
600 Volts 120/240 Volts 0.10 5 3.6 8100 9T58K1824G07
600 Volts 120/240 Volts 0.20 5 5.8 8175 9T58K1826G07
600 Volts 120/240 Volts 0.30 5 6.5 8200 9T58K1828G07
600 Volts 120/240 Volts 0.50 5 10.7 10225 9T58K1830G07
600 Volts 120/240 Volts 1 5 26.7 14225 9T58K1832G07
600 Volts 120/240 Volts 2 5 32.7 14300 9T58K1834G07
600 Volts 120/240 Volts 3 5 47.4 14475 9T58K1835G07

50/60 Hz Leads Out Connection2


Input Output Wiring Approx. Net Frame Product
Voltage Voltage kVA Diagram No.1 Weight (Lbs) Size Number
240x480 Volts 120/240 Volts 0.25 4 6.5 8200 9T58K1927G07
240x480 Volts 120/240 Volts 0.30 4 7.6 8250 9T58K1928G07
240x480 Volts 120/240 Volts 0.50 4 10.7 10225 9T58K1930G07
240x480 Volts 120/240 Volts 0.75 4 16.1 12300 9T58K1931G07
240x480 Volts 120/240 Volts 1.5 4 32.7 14300 9T58K1933G07
240x480 Volts 120/240 Volts 3 4 47.4 14475 9T58K1935G07
380/400/416 Volts 115/230 Volts 0.50 8 10.7 10225 9T58K1978G07
380/400/416 Volts 115/230 Volts 0.75 8 16.1 12300 9T58K1979G07
380/400/416 Volts 115/230 Volts 1 8 26.7 14225 9T58K1980G07
380/400/416 Volts 115/230 Volts 1.5 8 32.7 14300 9T58K1981G07
1See page 10-67 for wiring diagrams.
2Secondary fusing not available.

50/60 Hz Universal Voltage/Multitap Terminal Strip Connection Voltage Table


Frame Product Incoming Voltage Output Voltage
kVA Size Number H1 H2 H1 H3 H1 H4 H1 H5 X1 X2 X1 X3 X1 X4
208 500 85 100 110
0.25 10225 9T58K3715
415 86 104 113
0.35 10225 9T58K3716
220 380 440 550 91 110 120
0.50 12225 9T58K3717
230 40 460 575 95 115 125
0.75 12300 9T58K3718
240 416 480 600 99 120 130
1 14225 9T58K3719
1.5 14300 9T58K3720
2 14475 9T58K3721

Rev. 11/13 www.geindustrial.com BuyLogTM Catalog 10-65


Prices and data subject
to change without notice
Dry Type Transformers Section 10
Open Core and Coil Transformers
Options and Fusing Guide

Transformer Fusing Options


Accessory Description Product Number Accessory Description Product Number
(1) Quarter-Inch Fuseholder 9T58K0000G24 (2) CC + (1) Quarter-Inch Fuseholder 9T58K0000G48

(1) Midget Fuseholder 9T58K0000G42

(2) CC + (1) Midget Fuseholder 9T58K0000G38

(1) H/K Fuseholder 9T58K0000G10

(2) CC + (1) H/K Fuseholder 9T58K0000G18


(2) CC Fuseholder 9T58K0000G43

(2) H/K Fuseholder 9T58K0000G05


(2) CC Fuseholder 9T58E0000G46
(2) CC + (1) Midget Fuseholder 9T58E0000G47
Jumper Links 9T58K0000G01

Fuse Guide
Midget Class CC Rejection Fuse
Transformer Continuous Power Rating (VA)
Primary 50 75 100 150 200 250 300 375 500
Voltage Fuse Rating (Amperes)
100 1.50 2.00 3.00 4.00 3.00 4.00 5.00 6.00 8.00
110 1.25 2.00 2.50 4.00 5.00 3.00 4.00 5.00 7.00
120 1.25 1.60 2.50 3.00 5.00 3.00 4.00 5.00 6.00
200 0.75 1.00 1.50 2.00 3.00 3.00 4.00 5.00 4.00
208 0.60 1.00 1.25 2.00 2.50 3.00 4.00 5.00 4.00
220 0.60 1.00 1.25 2.00 2.50 3.00 4.00 5.00 3.00
230 0.60 0.80 1.25 1.60 2.50 3.00 3.00 4.00 3.00
240 0.60 0.80 1.25 1.60 2.50 3.00 3.00 4.00 3.00
277 0.50 0.80 1.00 1.60 2.00 2.50 3.00 4.00 5.00
380 0.30 0.50 0.75 1.00 1.50 1.60 2.00 2.50 3.00
400 0.30 0.50 0.75 1.00 1.50 1.60 2.00 2.50 3.00
416 0.30 0.50 0.60 1.00 1.25 1.60 2.00 2.50 3.00
440 0.30 0.50 0.60 1.00 1.25 1.60 2.00 2.50 3.00
460 0.30 0.40 0.60 0.80 1.25 1.60 1.60 2.00 3.00
480 0.30 0.40 0.60 0.80 1.25 1.50 1.60 2.00 3.00
550 0.25 0.40 0.50 0.80 1.00 1.25 1.60 2.00 2.50
575 0.25 0.30 0.50 0.75 1.00 1.25 1.50 1.60 2.50
600 0.25 0.30 0.50 0.75 1.00 1.25 1.50 1.60 2.50

For motor control circuits fusing, refer to NEC 430-72.

Secondary Fuse Selection


Glass Fuse
Transformer Continuous Power Rating (VA)
Secondary 50 75 100 150 200 250 300 375 500 750 1000 1500 2000 3000
Voltage Fuse Rating (Amperes)
12 6.00 10.00 12.00 15.00 20.00 25.00 30.00
24 3.00 5.00 6.00 10.00 12.00 12.00 15.00 25.00
36 2.00 3.00 4.00 6.00 8.00 10.00 12.00 15.00
48 1.50 2.50 3.00 5.00 6.00 8.00 10.00 12.00 12.00
95 0.80 1.25 1.60 2.50 3.00 4.00 5.00 6.00 8.00 12.00 15.00 20.00 25.00
110 0.75 1.00 1.50 2.00 3.00 3.00 4.00 5.00 7.00 10.00 12.00 20.00 25.00 30.00
115 0.60 1.00 1.25 2.00 2.50 3.00 4.00 5.00 7.00 10.00 12.00 20.00 20.00 30.00
120 0.60 1.00 1.25 2.00 2.50 3.00 4.00 5.00 6.00 10.00 12.00 15.00 20.00 30.00
208 0.40 0.60 0.80 1.00 1.60 2.00 2.00 3.00 4.00 6.00 8.00 12.00 15.00 20.00
220 0.30 0.50 0.75 1.00 1.50 1.60 2.00 2.50 3.00 5.00 7.00 10.00 12.00 20.00
230 0.30 0.50 0.60 1.00 1.25 1.60 2.00 2.50 3.00 5.00 7.00 10.00 12.00 20.00
240 0.30 0.50 0.60 1.00 1.25 1.60 2.00 2.50 3.00 5.00 6.00 10.00 12.00 15.00

10-66 BuyLogTM Catalog www.geindustrial.com Rev. 11/13


Prices and data subject
to change without notice
Dry Type Transformers Section 10
Open Core and Coil Transformers
Machine Tool Applications
Control
Wiring Diagrams

Diagram 1 Diagram 5

Diagram 2 Diagram 6

Diagram 3 Diagram 7

Diagram 4 Diagram 8

Rev. 11/13 www.geindustrial.com BuyLogTM Catalog 10-67


Prices and data subject
to change without notice
Dry Type Transformers Section 10
Open Core and Coil Transformers
Outlines and Dimensions
6, 8, 10, 12 and 14 Frames

Terminal Board and Leads Out Connection Style


Frame Approx. Net A Depth B Width C Height E Mounting F Mounting Mounting
Size Outline Weight (Lbs.) (in.) (in.) (in.) Depth (in.) Width (in.) Slot (in.)
G
6100 303B957AA 2.4 3.75 3 2.65 2.16 2.5 .219x.750
6125 303B957AA 2.8 4 3 2.65 2.41 2.5 .219x.750
F
6150 303B957AA 3.1 4.25 3 2.65 2.66 2.5 .219x.750
8100 303B957CA 3.6 4 3.75 3.28 2.16 3.13 .219x.750
8150 303B957CA 5.1 4.5 3.75 3.28 2.66 3.13 .219x.750
8175 303B957CA 5.8 4.75 3.75 3.28 2.91 3.13 .219x.750
8200 303B957CA 6.5 5 3.75 3.28 3.16 3.13 .219x.750
8250 303B957CA 7.6 5.5 3.75 3.28 3.66 3.13 .219x.750
10225 303B957EA 10.7 5.62 4.5 3.9 3.38 3.75 .297x.580
12225 303B957GA 12 5.88 5.25 4.53 3.38 4 .297x.580
12300 303B957GA 16.1 6.62 5.25 4.53 4.12 4 .297x.580
14225 303B957JA 26.7 6.5 6.75 5.78 3.38 5.5 .297x.580
14300 303B957JA 32.7 7.25 6.75 5.78 4.12 5.5 .297x.580
14475 303B957JA 47.4 9 6.75 5.78 5.88 5.5 .297x.580
F S

Style AA Style AB
(Terminal Blocks) Top (Leads Out)
Top

E
E

G G
(MTG Slot) F (MTG Slot)
F

B A B A

C C

Front Side Front Side

S
T

10-68 BuyLogTM Catalog www.geindustrial.com Rev. 11/13


Prices and data subject
F S to change without notice
Dry Type Transformers Section 10
Open Core and Coil Transformers
CE-Rated
Application
This product is designed to be incorporated into equipment man-
ufactured for sale in the European Community. This product is in
conformity with the European Standard:
EN 60 742, 1995 per the provisions of the Low Voltage (LV)
Directive 73/23/EEC in 1973 as amended by 93/68/EEC in 1995.
The Type IP offering utilizes all copper windings, which are
encapsulated in a hardened epoxy, making the winding impervi-
ous to the elements. These designs are rated at 55 C rise with a
40 C ambient. Standard on these designs are terminal board
covers. These provide added protection from current carrying ter-
minals. These designs incorporate customer friendly connection
on rugged high-impact molded terminal boards.
Besides being rated, these designs are both UL and C-UL listed.

50/60 Hz
Input Output Approx. Net Frame Product
Voltage Voltage kVA Weight (Lbs) Size Number
230/400 Volts 12/24 Volts 0.025 3 6100 9T58E0020
230/400 Volts 12/24 Volts 0.05 4 6150 9T58E0021
230/400 Volts 12/24 Volts 0.075 4 8100 9T58E0023
230/400 Volts 12/24 Volts 0.1 5 8150 9T58E0024
230/400 Volts 12/24 Volts 0.15 7 8200 9T58E0025
230/400 Volts 12/24 Volts 0.2 12 10225 9T58E0026
230/400 Volts 12/24 Volts 0.25 12 10225 9T58E0027
230/400 Volts 12/24 Volts 0.3 12 10225 9T58E0028
230/400 Volts 12/24 Volts 0.375 16 12225 9T58E0029
230/400 Volts 24/48 Volts 0.05 4 6150 9T58E0061
230/400 Volts 24/48 Volts 0.075 4 8100 9T58E0063
230/400 Volts 24/48 Volts 0.1 5 8150 9T58E0064
230/400 Volts 24/48 Volts 0.15 7 8200 9T58E0065
230/400 Volts 24/48 Volts 0.2 12 10225 9T58E0066
230/400 Volts 24/48 Volts 0.5 19 12300 9T58E0071
230/400 Volts 24/48 Volts 0.75 28 14225 9T58E0073
220/380, 230/400, 240/415 Volts 110/220, 115/230, 120/240 Volts 0.025 3 6100 9T58E0150
220/380, 230/400, 240/415 Volts 110/220, 115/230, 120/240 Volts 0.05 4 6150 9T58E0151
220/380, 230/400, 240/415 Volts 110/220, 115/230, 120/240 Volts 0.075 4 8100 9T58E0153
220/380, 230/400, 240/415 Volts 110/220, 115/230, 120/240 Volts 0.1 5 8150 9T58E0154
220/380, 230/400, 240/415 Volts 110/220, 115/230, 120/240 Volts 0.15 7 8200 9T58E0155
220/380, 230/400, 240/415 Volts 110/220, 115/230, 120/240 Volts 0.2 12 10225 9T58E0156
220/380, 230/400, 240/415 Volts 110/220, 115/230, 120/240 Volts 0.25 12 10225 9T58E0157
220/380, 230/400, 240/415 Volts 110/220, 115/230, 120/240 Volts 0.3 12 10225 9T58E0158
220/380, 230/400, 240/415 Volts 110/220, 115/230, 120/240 Volts 0.375 16 12225 9T58E0159
220/380, 230/400, 240/415 Volts 110/220, 115/230, 120/240 Volts 0.5 19 12300 9T58E0161
220/380, 230/400, 240/415 Volts 110/220, 115/230, 120/240 Volts 0.75 28 14225 9T58E0163
220/380, 230/400, 240/415 Volts 110/220, 115/230, 120/240 Volts 1 34 14300 9T58E0164
220/380, 230/400, 240/415 Volts 110/220, 115/230, 120/240 Volts 1.5 45 14475 9T58E0165

Factory- or Field-Installed Options


Available as an option are two fuse blocks that have fuse covers
that provide the touch safety like the terminal blocks. These can
be ordered factory-installed or as kits.
In kit form order:
Fuse block for 2 class CC fuses is 9T58E0000G46. Fuse block for 2
class CC and 1 Midget fuse is 9T58E0000G47.
For factory installation add the G46 or G47 suffix to the trans-
former product number (example 9T58E0020G47).

Rev. 11/13 www.geindustrial.com BuyLogTM Catalog 10-69


Prices and data subject
to change without notice
Section 10

NOTES:

10-70 BuyLogTM Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Section Updated 01 / 2017

Panelboards Section 11

FE as a main breaker in A-Series II Panelboards: Expanding


GEs selectivity offering. The FE main breaker in A-Series II allows
full instantaneous selectivity, which can be coordinated with
upstream and downstream GE breakers.

A-Series II Branch Circuit Monitoring (BCM): This new energy


management product allows for monitoring key electrical param-
eters down to a branch circuit level. This product is factory
installed which makes for a clean installation and reduced labor
in the field.

AS style A-Series II panel: New AE subtype panel, AS, allows


for the combination of expanded selectivity and fully rated solu-
tion up to 65kAIC at 480V. This solution also decreases overall
footprints of our panelboard, which has an important aspect of
current day installations.

A-Series II Panelboards
Applications................................................................................................11-3
Types..............................................................................................................11-4
Terminal Lugs............................................................................................ 11-7
Pricing and Ordering.............................................................................. 11-8
Column Panels.......................................................................................... 11-9
Column Field Installed Kits/Replacement
Parts/Enclosures.................................................................................11-10
Lighting Control PanelRemote Operated
Circuit Breakers...................................................................................11-11
Pro-Stock Panelboards Unassembled.....................................11-13
Product Options..................................................................................... 11-19
Accessories.............................................................................................. 11-20
Power Panelboards.............................................................................. 11-21
Branch Circuit Monitoring.................................................................11-23
AMP1 Integrated Power and Energy............................................11-24
Spectra Series Panelboards................................................. 11-25
Fusible Switches Load and Interrupting Ratings................... 11-26
Merchandisable Kits and Sizing Information...........................11-28
Terminal Lugs..........................................................................................11-29
PCU Selection..........................................................................................11-30
Interior, Enclosure Options................................................................11-31
Integrated Submetering Panelboard...........................................11-33
Renewal Parts Modular Concept...................................................11-34
Renewal Parts Circuit Breaker Sizing...........................................11-35
Replacement Boxes and Fronts..................................................... 11-36
Renewal Parts Product Number Structure............................... 11-38
Renewal Parts Mounting Hardware......................................... 11-41
Renewal Parts Main Lug Modules;
Neutral and Ground Kits.................................................................11-46
Renewal Parts Accessories...........................................................11-47
Renewal Parts Interiors, Boxes and Fronts...........................11-48
Renewal Parts Type SCP Panelboards.................................... 11-49
Renewal Parts Type CCB and QMR Panelboards............... 11-50
Available Publications............................................................. 11-53

Rev. 11/13 www.geindustrial.com BuyLog Catalog 11-1


Data subject to change
without notice
This page left blank intentionally.

11-2 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Panelboards Section 11
A-Series II Panelboards
Applications
Standards
All GE panelboards meet the latest revision of the following
standards.
National Electrical Code-Ref. Article 384.
UL67 panelboards: UL50 cabinets and boxes. UL943 GFCI.
UL489 molded case circuit breakers. UL98 fusible switches.
cUL listing for Spectra Series Power Panelboards.
CSA Listing for A-Series II non-service entrance panelboards
International Building Code Seismic Zone 3 and 4.
California Building Code Seismic Zone 4.

NEMA PB1.
Federal Specifications
Panelboards, W-P-115c.
Type 1Circuit breaker equipped
Class 1Panelboards
Class 2Load centers
Molded case circuit breakers, WC-375B/GEN.
Fusible switches, W-S-865c.

Application Features
The following classifications and limitations of panelboards have Symmetrical design, no required top or bottom mountings
been established by the Underwriters Laboratories and the Wide, easy-to-install galvanized enclosures with removable
National Electrical Code. Note an overcurrent protective device endwalls
is a circuit breaker pole or single fuse. Panelboards have no fire
Flush or surface mounting
wall ratings. All 50/60 Hz rated. There is no limitation as to the
number and rating of branch circuits, except as determined by Standard concealed mounting hardware and hinges
available enclosures. Interiors that allow straight-in wiring
Split neutral
Interrupting RatingsCircuit Breakers Field-installable, UL Listed, 200% neutral for non-linear loads
Panelboards have integrated short circuit ratings. When fully Branch-bus direct connection
rated, the rating is that of the lowest rated device in the panel-
Captive hardware on branch breakers
board. When series connected rated, the rating is that of the
main device in panel (or remote line side protected device) and Short circuit ratings allow up to 100KA @ 480Y/277Vac; 200KA
branch-tested/UL Listed combination. @ 240Vac
Main bus ratings of 125 to 800 amps copper, 125 to 600 amps
aluminum
Short-Circuit RatingsFusible Switch Units
Spectra RMS and vertically mounted main circuit breakers
The interrupting rating of the fuse must equal or exceed the
short-circuit rating of the switch. If it is lower, then the interrupt- available
ing rating of the switch is the same as the fuse. Switches have no Bus-connected TVSS for maximum surge protection
short-circuit rating if renewable fuses are used. Optional door-in-door or front-hinged-to-box door
Enclosures available in NEMA Type 1, Type 3R/12, Type 4/4X
Seismic Ratings
All A-Series II Lighting Panels and Spectra Power Panels have
been tested and certified to meet the International Building Code
(IBC) Zone 3 and Zone 4 as well as the California Building Code
(CBC) Zone 4.

Rev. 11/13 www.geindustrial.com BuyLog Catalog 11-3


Data subject to change
without notice
Panelboards Section 11
A-Series II Panelboards
Types
Type AL
Service Information:
1P, 3W-120/240 Vac
3P, 3W-240 Vac
3P, 4W-240/120 Vac, 208/120 Vac
Mains
Breakers:
100A-THQB, THHQB, TEY, SE, FE
225A-TQD, THQD, SF, FE
400A-TJD, SG
600A-SG
800A-SK
Main Lug:
125-800A
Branch Breakers (Plug-in):
Amperage-15-100A
Poles-1, 2, 3
Types-THQL, THHQL, TXQL
Enclosures
Length-25.5, 31.5, 37.5, 43.5, 49.5, 55.5, 64.5, 76.5, 82.5, 88.5
Width-20
Depth-5.81

Type AQ
Service Information:
1P, 3W-120/240 Vac
3P, 3W-240 Vac
3P, 4W-240/120 Vac, 208/120 Vac
Fully Rated: 65kAIC at 240V
Series Rated: 200kAIC at 240V
Mains
Breakers:
100A-THQB, THHQB, TEY, SE, FE
225A-TQD, THQD, SF, FE
400A-TJD, SG, FG
600A-SG
800A-SK
Main Lug:
125-800A
Branch Breakers (Bolt-on):
Amperage-15-100A
Poles-1, 2, 3
Types-THQB, THHQB, TXQB
Enclosures
Length-25.5, 31.5, 37.5, 43.5, 49.5, 55.5, 64.5, 76.5, 82.5, 88.5
Width-20
Depth-5.81

11-4 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Panelboards Section 11
A-Series II Panelboards
Types
Type AE (includes subtype AS)
Service Information:
1P, 3W-120/240 Vac, 125/250 Vdc
3P, 3W-240 Vac
3P, 4W-480/277 Vac, 208/120 Vac, 240/120 Vac
Fully Rated: 65kAIC at 480Y/277V, 100kAIC at 240V
Series Rated: 100kAIC at 480V
Mains
Breakers:
100A-TEY, SE, FE
225A-TFJ, SF, FE
400A-TJJ, SG, FG
600A-SG
800A-SK
Main Lug:
125-800A
Branch Breakers (Bolt-on):
Amperage-15-100A
Poles-1, 2, 3
Types-TEY, TEYF, TEYD, TEYH, TEYL
Amperage-110A, 125A
Poles-2, 3
Types-TEYD, TEYH, TEYL
Enclosures
Length-25.5, 31.5, 37.5, 43.5, 49.5, 55.5, 64.5, 76.5, 82.5, 88.5
Width-20
Depth-5.81
Note: Bold items are features of AS Panels

Type AD
Service Information:
3P, 3W-480 Vac, 600 Vac
3P, 4W-208/120 Vac, 480/277 Vac, 600/347 Vac
Fully Rated: 35kAIC at 600Y/347V, 100kAIC at 480V
Series Rated: 35kAIC at 600Y/347V
Mains
Breakers:
150A-THED, SE
225A-TFJ, SF
400A-TJJ, SG
600A-SG
800A-SK
Main Lug:
150-800A
Branch Breakers (Bolt-on):
Amperage-15-100A (1P, 2P)
15-150A (3P)
220A Max. double branch
Types-TED, SE, FB
Enclosures
Length-31.5, 37.5, 43.5, 49.5, 55.5, 64.5, 76.5, 82.5, 88.5
Width-20
Depth-5.81

Rev. 11/13 www.geindustrial.com BuyLog Catalog 11-5


Data subject to change
without notice
Panelboards Section 11
A-Series II Panelboards
Types

Panelboard Types

A-Series II Column Type Panels Distribution Panels


Lighting
AL AQ AE/AS AD/AD Plus Control Panel ALC AQC AEC Spectra
Item Page 3-4 Page 3-4 Page 3-5 Page 3-5 Page 3-11 Page 3-9 Page 3-9 Page 3-9 Page 3-25

Max. 480Y/277Vac1 480/277Vac 600Vac


240Vac 240Vac 600Vac 480Y/277Vac 240Vac 240Vac
Voltage 125/250Vdc 125/250Vdc 250Vdc

Max. Main Lug 800A 800A 800A 800A 400A 225A 225A 225A 1200A
Amperes

Max. Main Breaker 800A 800A 800A 800A 400A 225A 225A 225A 1200A
or Switch Amperes

THQB, THHQB, TQD, THQD, TEY, TFJ, TJJ, TEYF, TEY, SE, TFJ, THQB, THHQB, TQD, TEY, TFJ, SF, SG, SK,
THED, TFJ, TJJ
Main Devices TEY, TJD, TFJ TEYD, TEYH, TEYL SF, TJJ, THQD, TEY, TFJ, SE, SF ADS Switches,
SE, SF, SG, SK SG SE, SF FB, FC, FE, FG

Branches 100A-1 ph, 2ph 80A-8 1/2 Box


100A 100A 125A 100A 100A 100A 1200A
Max. Amps 150A-3 ph 80A-7 1/2 Box

THQB, THQB, TED, SE, SF, SG, SK,


Branch THHQB, TEY. TEYF, TEYD5, FB,TED, TEYRC, TEY, THQL, THHQB, THQB, THHQB, TEY,
THQL, THHQL TEYH5, TEYL5 THQBGF TEY
Devices TXQB THED, SE THHQL TXQB TQD, ADS Switches,
(Bolt-on) (Bolt on) FB, FC, FE, FG

Subfeeds
Max. Amps 225 225 225 225 225 150 150 150
(100% Rated)
Subfeed
TQD, THQD TQD, THQD TED, TFJ, SE, SF TED, TFJ, SE, SF TED, TFJ, SE, SF TQD, THQD TQD, THQD TED
Breaker Types

A-Series II Standard Main Breaker Types and Ratings


Panel Type
AQ/AL AE / Lighting Control Panel AD / AD Plus
IC
Ratings Voltage 100A 225A 400A3 600A3 800A3 150A 225A 400A 600A 800A 150A 225A 400A 600A 800A
10 240 THQB TQD/TFJ SKHA8
22 240 THHQB THQD TJD SGHA6
65 240 TEY SFHA SGHA4 SGHA6 SFHA4 SGHA44 SGHA6
100 240 SEL/TEYL SFL SGL SGL6
200 240 SEP SFP SGPA4
142 480Y/277 TEY4 TFJ4 SGHA/TJJ4 SGHA6 SKHA8 TED TFJ TJJ
35 480Y/277 SEHA SFHA SGHA4 SGHA6
18 SKHA8
25 SEHA4/TEYD SFHA4 SEHA SFHA
65 480Y/277 SELA4/TEYL SFLA4 SGLA4 SGLA6
100 480Y/277 SEPA4 SFPA SEPA SFPA SGPA4 SGPA6
142 480 TED TFJ TJJ SGHA6
65 480 SELA SFLA SGLA4 SGLA6
100 480 SEPA SFPA SGPA4 SGLA6
182 600 THED TFJ TJJ SGHA6 SKHA6
25 600 SELA SFLA SGHA4 SGHA6
35k2 600Y/347 SEPA SFPA SGPA4 SGPA6
1 AE Panels are suitable for use on 3-PH, 3W applications when derived from 3PH, 4W 480V/277 service
where the neutral is not connected to the panel. For 3ph-Delta use AD Panels.
2 Not series rated.
3 Not available in column panelboards.
4 Light Control Panel ratings.
5For installation in AS panels only.

11-6 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Panelboards Section 11
A-Series II Panelboards
Terminal Lugs
Molded Case Circuit Breakers
Circuit Breaker Frame Terminal Lugs (Cu-Al)

Current High No. Per Product WireCu-Al (Unless otherwise noted)


Standard Hi-Break Tri-Break Limiting Interrupting Poles Pole Number Per Lug Range
TXQL,
THQL 1,2,3
THHQL (15-30A) #14-4 Cu or #12-4 Al
1 1
TXQB, (35-100A) #14-1/0 Cu or #12-1/0 Al
THQB 1,2,3 Fixed to
THHQB
Breaker Terminal
(15-25A) #14-#12 Cu or #12-#10 Al
TEY 1,2,3 1 1 (30-60A) #10-#6 Cu or #8-#4 Al
(70-100A) #4-#1 Cu or #2-1/0 Al
TEB 1,2,3 TCAL14 (15-30A, TCAL14)#14-8
TED THED1 1 TCAL12 (30-60A, TCAL12)#14-3 Cu, #12-1 Al
1 1
TED4 2-3 TCAL12A (70-90A, TCAL12A)#6-2/0 Cu, #4-2/0 Al
TED6 THED 2-3 TCAL15 (100-150A, TCAL15)#3-3/0
FCAL12 (15-20A) #14-#12 Cu or #10-#12 Al
FBV FBN
1,2,3 1 FCAL13 1 (35-60A) #10-#6 Cu or #8-#4 Al
FBH FBL
FCAL14 (70-100A) #4-#1 Cu or #2-1/0 Al
FCALK12 (15-20A) #14-#12 Cu or #10-#12 Al
FCS FCV FCN
2,3 1 FCALK13 1 (35-60A) #10-#6 Cu or #8-#4 Al
FCH FCL
FCALK14 (70-100A) #4-#1 Cu or #2-1/0 Al
SEDA SEHA SELA SEPA 2-3 1 TCAL18 1 #12-3/0 Cu, #12-3/0 Al
FES1T FEV1T
2-3 1 FCALK15 1 #12-3/0 Cu, #14-1/0 Al
FEN1T FEH1T FEL1T
FES1E FEV1E
2-3 1 FCALK15 1 #12-3/0 Cu, #14-1/0 Al
FEN1E FEH1E FEL1E
TQD THQD 2-3 1 TCAL25 1 #1-300kcmil
SFHA SFLA SFPA 2-3 1 TCAL29 1 #8-350kcmil
TFJ, TFK THFK 2-3 1 TCAL24, 26 1 #4-300kcmil
FES2T FEV2T
2-3 1 FCALK16 1 #8-250kcmil Cu, #8-250kcmil
FEN2T FEH2T FEL2T
FES2E FEV2E
2-3 1 FCALK16 1 #8-250kcmil Cu, #8-250kcmil
FEN2E FEH2E FEL2E
SGDA SGL 2(2/0-400kcmil Cu) or
2 1 TCLK2652
SGHA SGP 2(2/0-500kcmil Al) or #6-600kcmil
SGDA SGL 2(2/0-400kcmil Cu) or
3 1 TCLK3652
SGHA SGP 2(2/0-500kcmil Al) or #6-600kcmil
FGV2 Top hole #8-400kcmil Cu or
FGN2 FGH2 2-3 1 FCALK318H #6-500kcmil Al
FGL2 FGP2 Bottom hole #2/0-600kcmil Cu & Al
FGV4 Top hole #8-400kcmil Cu or
FGN4 FGH4 2-3 1 FCALK318H #6-500kcmil Al
FGL4 FGP4 Bottom hole #2/0-600kcmil Cu & Al
FGV6 Top hole #8-400kcmil Cu or
FGN6 FGH6 2-3 1 FCALK318H #6-500kcmil Al
FGL6 FGP6 Bottom hole #2/0-600kcmil Cu & Al
TJJ, TJK4 THJK4 TB4 2-3 1 TCAL43 1 #6-600kcmil or 2-(2/0-250kcmil)
TJD 2-3 1 TCAL43 1 #6-600kcmil or 2-(2/0-250kcmil)
TCAL43 1 #6-600kcmil or 2-(2/0-250kcmil)
TJK6 THJK6, THJ4V 2-3 1
TCAL63 2 250-350kcmil, Cu, or 350-500kcmil, Al
TB6 3 1 TCAL61 2 2/0-500kcmil
TCAL41 1 #4-600kcmil or 2-(1/0-250kcmil)
SKHA8 SKLA8
THKM8 2-3 1 TCAL61 2 2/0-500kcmil
TKM84 SKPA8
TCAL81 3 3/0-500kcmil
Load End 1 TCAL91 3 3/0-500kcmil
TB8 3 1 TCAL81 3 3/0-500kcmil
SKHA12, SKLA12, TCAL81 3 3/0-500kcmil
THKM12 2-3 1
TKM124 SKPA12 TCAL121 4 250-350kcmil Cu or 350-5000kcmil Al
Load End 2-3 1 TCAL131 4 250-350kcmil Cu or 350-500kcmil Al
TCAL12 (15-60A, TCAL12)#14-#3 Cu or #12-#1 Al
TB1 THLC1 3 1 TCAL12A 1 (70-100A, TCAL12A)#6-2/0 Cu or #4-2/0 Al
TCAL15 (100-150A, TCAL15)#3-3/0 Cu or #1-3/0 Al
THLC2 3 1 TCAL27 1 (125-225A, TCAL27)#4-300kcmil
THLC4 TLB44 3 1 TCLK433 3/0-500kcmil or 2-(3/0-250kcmil)
1One-pole THED frame available only in 15-30 amp trip. 3Three-pole lug assembly suitable for line or load end.
2Lug kitincludes line or load end cover. 4For replacement use only.

ADS Fusible Switch Module Terminations (CU/AL Mechanical)5


Amp Rating Voltage Wire Size (CU/AL) # Wires Per Lug # Lugs Per Phase
30 240/600 #2-#14 1 1
60 240 #2-#14 1 1
60 600 #14-I/O 1 1
100 240/600 #14-I/O 1 1
200 240/600 #6-250kcmil 1 1
400 240/600 I/O-250kcmil or #2-600kcmil 2 or 1 1
600 240/600 I/O-250kcmil or #2-600kcmil 2 or 1 1
800 600 I/O-250kcmil or #2-600kcmil 2 or 1 1
1200 600 I/O-250kcmil or #2-600kcmil 2 or 1 1
5 For optional mechanical or compression lugs refer to GET-7006.

Rev. 11/13 www.geindustrial.com BuyLog Catalog 11-7


Data subject to change
without notice
Panelboards Section 11
A-Series II Panelboards
Pricing and Ordering

Information Required to Price and Order a Panelboard How to Price Factory Assembled Panelboards
Short-circuit Rating (10kA, 18kA, etc.) Main Price (or Interior Price for A-Series II) + Branch Circuits +
Service Entrance Label (Yes) or (No) Options = Total List of Panelboard. The sum of these list prices is
the total list for the complete panelboard including box and front.
Mark(s) (LPA, MDP, RPC, etc.)
Please refer to Speedi for quoting, pricing and ordering GE panels
Service (3-ph, 4-w 208Y/120; 3-ph, 3-w 480 volts, etc.)
Entrance of Incoming Line (Top) or (Bottom).
How to Lay Out Factory Assembled Panelboards
(Bottom Supplied as Standard)
Multi-section panels must have a main circuit breaker or main
Trim (Surface) or (Flush)
lugs in each section. Double (dual) main lugs or thru-feed lugs
Incoming Wire Size (500kcmil, 250kcmil, etc.) must be added as required in all but the last section.
Incoming Number of Wires per phase (1, 2, 3, etc.) Please refer to Speedi for quoting, pricing and ordering GE panels
Wire Material (Copper or Aluminum)
Main Type (Main Lugs Only, Circuit Breaker, Fusible Switch, etc.) How to select a Pro-Stock, unassembled panelboard
Amperage of Main Bus Total the following components:
Interior
Frame of Main Circuit Breaker (SG, SK, TJK, etc.) (if applicable)
Box (add ground bars as required)
Options to Mains (Shunt Trip, Lighting Contactor, etc.)
Front
Equipment Ground (Optional)
Main breaker or lug kit
Branches
Amp Rating (20, 30, 50, etc.) Subfeed breaker or feed thru lug kit (if required)
Poles (1, 2, or 3) Branch Breakers (from Section 3)
Frame (THQB, TED, etc.) Accessories (200% neutral, service entrance etc.)
Quantity (1, 10, 15, etc.)
Please consult your local distributor for net pricing and current
Options: stock levels.
Interior (Copper bus, 200% rated neutral, etc.)
Box (Painted, Increased Gutter, etc.) For additional details on selecting Pro-Stock panelboards, please
Front (Door in Door, etc.) refer to publication DEP-104.
Ground Fault Protection (Yes) or (No)
Type of Panel (AQ, AE, Spectra Bolt-on, etc.)

11-8 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Panelboards Section 11
A-Series II Panelboards
Column Panels
Type ALC Type AEC
Service Information: Service Information:
1P, 3W-120/240 Vac 3P, 4W-480/277 Vac
3P, 4W208/120 Vac, 480/277 Vac Mains
3P, 4W-240 Vac Breakers:
Mains 100A-TEY, SE
Breakers: 225A-TFJ, SF
100A-THQB, THHQB, TEY, SE Main Lug:
225A-TQD, THQD, SF 125-225A
Main Lug: Branch Breakers (Bolt-on):
125-225A Amperage-15-80A (1P, 2P, 3P)
Branch Breakers (Plug-in): Types-TEY
Amperage-15-100A (1P, 2P, 3P) Enclosures
Types-THQL, THHQL, TXQL Length-37.5, 43.5, 49.5, 55.5, 64.5, 76.5
Enclosures Width-8.62
Length-37.5, 43.5, 49.5, 55.5, 64.5, 76.5 Depth-5.81
Width-8.62
Depth-5.81

Type AQC
Service Information:
1P, 3W-240/120 Vac
3P, 3W-240 Vac
3P, 4W-240 Vac
Mains
Breakers:
100A-THQB, THHQB, TEY, SE
225A-TQD, THQD, SF
Main Lug:
125-225A
Branch Breakers (Bolt-on):
Amperage-15-100A (1P, 2P, 3P)
Types-THQB, THHQB, TXQB
Enclosures
Length-37.5, 43.5, 49.5, 55.5, 64.5, 76.5
Width-8.62
Depth-5.81

Rev. 11/13 www.geindustrial.com BuyLog Catalog 11-9


Data subject to change
without notice
Panelboards Section 11
A-Series II Panelboards
Column
Field Installed Kits/Replacement Parts

Miscellaneous Kits Panelboards Parts


Order by Product Number from the National Service Center Order from Factory

Product Description Product Number


Description Number
Directory Card 139C5612P2
Equipment Grounds:
Circuit Numbering
Standard Terminal Strip
With Provision for Strips - 1-48 569B806G1
(11) 14-8 Cu or 12-8 Al TGL2
43-84 569B806G2
(3) 14-4 Cu or 6-4 Al
Directory Card Holder 139C5491P4
Above terminal with Copper Strap TGC2
Main Lug 6-2/0 Cu/Al TGL20
Standard Isolated Insulated
(11) 14-8 Cu or 12-8 Al EGS12
(3) 14-4 Cu or 6-4 Al
Above terminal with Copper Strap EGC12 Permanent Circuit Number Kits
Handle Locking Devices: Order from Factory
THQL, THHQL THQB, THHQB THL103
Product Number Description
TEY TEYLD1
APN48 No's 1-48
TED TLD3
APN84 No's 43-84
TFJ, TFL, TLB4 TFKLD1
Padlocking Devices:
THQL, THHQL, TXQL
THQB, THHQB, TXQB THP100

TEY TEYPLD1
TED, TEL TEFPLD1
TQD TQDPLD1
TFJ, TFL TFKPLD1
Filler Plate for Q Line
and TEY Breakers TQLFP1

Gasketing Kit AGSK


Safety Catch for Trough Covers 1 ACHK
1
Standard on pull box.

11-10 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Panelboards Section 11
A-Series II Panelboards
Lighting Control Panel
480Y/277 Vac/120/208 Vac
Remote Operated Circuit Breakers
Bolt-On Factory Assembled
Three-Phase, 4-Wire Pricing
Service Information:
1P, 3W-120/240 Vac
3P, 4W-208/120 Vac, 480/277 Vac
Mains
Breakers:
100A-TEY, SE
225A-TFJ, SF
400A-TJJ, SG
Main Lug:
125-400A
Branch Breakers (Bolt-on):
Amperage-15-30A (1P, 2P): TEYRC
15-100A (1P, 2P, 3P): TEY
220A Max. double branch
Types- TED, SE, FB
Enclosures
Length-25.5 31.5, 37.5, 43.5, 49.5, 55.5, 64.5, 76.5
Width-20
Depth-5.81

Rev. 11/13 www.geindustrial.com BuyLog Catalog 11-11


Data subject to change
without notice
Panelboards Section 11
A-Series II Panelboards
Lighting Control Panel
480Y/277 Vac/120/208 Vac
Remote Operated Circuit Breaker

Accessories
Product
Description Number
Programming Software ASROCBPRGM
PC-based start up software
Daylight Optimization Module ASRGLCDOK
Performs sunlight harvesting by measuring the
amount of light and provides a control signal to a
dimming mechanism to maintain a preset lighting level.
Remote Switch Expansion Module ASRGLCDSK
Provides additional 16 digital input
signals to the controller for each module
Control Wiring Insulation Tubing ASRGLCCWT
Requirement per UL67 and NEC725.55, that low
voltage class 2 and 3 control wiring be separated with
tubing having an insulation rating equal to branch load wiring.
Programming Software

Dimming Module

Remote Switch Module

11-12 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Panelboards Section 11
A-Series II Panelboards
Pro-Stock, Unassembled Lighting Panels
100-600A
240 Vac 1 or 3 Phase or 480Y/277 Vac 3 Phase
Order by Product Number from the Customer Service Center
1 Select Interior
Select the interior by bus type, panel rating and number of circuits. Identify the box/front
height for use in Steps 2 and 3.
Copper Bus
Feed-thru Non Feed-thru
Rating No. of Product Box/Front Product Box/Front TGL2 Ground
Voltage (Amps) Circuits Number1 Height Number1 Height Bars2,3
18 AQU1182RCXAXT1B4 37.5" AQU1182RCXAXB4 31.5" 2
100- 30 AQU1302RCXAXT1B4 43.5" AQU1302RCXAXB4 37.5" 3
225
240 Vac, 42 AQU1422RCXAXT1B4 49.5" AQU1422RCXAXB4 43.5" 4
1 Phase 18 AQU1184RCXAXT1B4 64.5" 2
400
42 AQU1424RCXAXT1B4 76.5" AQU1424RCXAXB4 64.5" 4
18 AQU1186RCXAXT1B4 64.5" 2
600
42 AQU1426RCXAXT1B4 76.5" AQU1426RCXAXB4 64.5" 4
18 AQU3182RCXAXT1B4 37.5" AQU3182RCXAXB4 31.5" 2
100- 30 AQU3302RCXAXT1B4 43.5" AQU3302RCXAXB4 37.5" 3
225
208/120 42 AQU3422RCXAXT1B4 49.5" AQU3422RCXAXB4 43.5" 4
Vac, 18 AQU3184RCXAXT1B4 64.5" 2
400
3 Phase 42 AQU3424RCXAXT1B4 76.5" AQU3424RCXAXB4 64.5" 4
18 AQU3186RCXAXT1B4 64.5" 2
600
42 AQU3426RCXAXT1B4 76.5" AQU3426RCXAXB4 64.5" 4
18 AEU3182RCXAXT1B4 37.5" AEU3182RCXAXB4 31.5" 2
100- 30 AEU3302RCXAXT1B4 43.5" AEU3302RCXAXB4 37.5" 3
225
480/277 42 AEU3422RCXAXT1B4 49.5" AEU3422RCXAXB4 43.5" 4
Vac, 18 AEU3184RCXAXT1B4 64.5" 2
400
3 Phase 42 AEU3424RCXAXT1B4 76.5" AEU3424RCXAXB4 64.5" 4
18 AEU3186RCXAXT1B4 64.5" 2
600
42 AEU3426RCXAXT1B4 76.5" AEU3426RCXAXB4 64.5" 4

Aluminum Bus
Rating No. of Feed-thru Box/Front TGL2
Voltage (Amps) Circuits Product Number1 Height Ground Bars2,3

18 AQU1182RCXAXT1 37.5" 2
240 Vac,
100-225 30 AQU1302RCXAXT1 43.5" 3
1 Phase
42 AQU1422RCXAXT1 49.5" 4
18 AQU3182RCXAXT1 37.5" 2
208/120 Vac,
100-225 30 AQU3302RCXAXT1 43.5" 3
3 Phase
42 AQU3422RCXAXT1 49.5" 4
18 AEU3182RCXAXT1 37.5" 2
480/277 Vac,
100-225 30 AEU3302RCXAXT1 43.5" 3
3 Phase
42 AEU3422RCXAXT1 49.5" 4

TGL20 Ground Lug Quantities


No. of TGL20s Required
by Panel Rating
Interior Type 100A-225A 400A 600A
Main Lug Only 1 1 2
Main Lug and Feed-thru 2 2 4
Main Breaker Only 1 1 1
Main Breaker and Sub-feed 1 1 1
Main Breaker and Feed-thru 2 2 3
1For CSA label, add "M8" suffix to product number.
2For TGL20 ground lug quantities, see TGL20 Ground Lug Quantities table above.
3For isolated ground, use EGS12. When using the EGS12, 3, 5 and 7 ground lugs
(TGL20s) are required for 18, 30 and 42 circuits respectively.

Rev. 11/13 www.geindustrial.com BuyLog Catalog 11-13


Data subject to change
without notice
Panelboards Section 11
A-Series II Panelboards
Pro-Stock, Unassembled Lighting Panels

2 Select Box
Select a box of the correct height (see Step 1). Boxes come with blank endwalls.
If endwalls with knockouts are required, also order knockout endwall kit AKEW2.

NEMA 1 NEMA 3R/12


20" Wide 30" Wide 20" Wide
Box Product Product Product
Height Number1 Number1 Number1
31.5" AB31B AB31BW AB313
37.5" AB37B AB37BW AB373
43.5" AB43B AB43BW AB433
49.5" AB49B AB49BW AB493
64.5" AB64B AB64BW AB643
76.5" AB76B AB76BW AB763
NEMA 1
1For CSA label, add "A" suffix to product number.

NEMA 3R/12

3 Select Front
Select a front of the correct height (see Step 1).
Standard (20" wide) Door Within Door (20" wide) Front Hinged To Box (20" wide) Standard (30" Wide)

Front Height Flush1 Surface1 Flush1 Surface1 Flush1 Surface1 Flush1 Surface1
31.5" AF31F AF31S AF31FP AF31SP AF31FD AF31SD AF31FW AF31SW
37.5" AF37F AF37S AF37FP AF37SP AF37FD AF37SD AF37FW AF37SW
43.5" AF43F AF43S AF43FP AF43SP AF43FD AF43SD AF43FW AF43SW
49.5" AF49F AF49S AF49FP AF49SP AF49FD AF49SD AF49FW AF49SW
64.5" AF64F AF64S AF64FP AF64SP AF64FD AF64SD AF64FW AF64SW
76.5" AF76F AF76S AF76FP AF76SP AF76FD AF76SD AF76FW AF76SW
1For CSA label, add "A" suffix to product number.

Door Within Door Standard Front Hinged to Box

11-14 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Panelboards Section 11
A-Series II Panelboards
Pro-Stock, Unassembled Lighting Panels

4 Select Main and/or Sub-feed Breaker Kit


Select main breaker kit appropriate for your interior type (see Step 1), amp rating and kAIC rating. If a sub-feed breaker is required,
repeat the selection process.

Note: 400A and 600A breaker kits cannot be used for sub-feed applications in Pro-Stock panelboards.

For additional details, see Section 6 of the BuyLog.

Interior Product Rating No. of Breaker Rating (kAIC)


Type Number1 Amps Poles 10 14 22 25 65 100 200
MB612 100 2 THQB THHQB
MB614 100 4 (2) THQB (2) THHQB
MB512 225 2 TQD THQD
MB332 400 2 SGHA SGLA SGPA
AQU1:
MB331WB 400 3 SGDA+Kit
240 VAC
MB335WB 400 2 SGDA+Kit
1 Phase
MB334WB 400 3 SGDA+Kit
MB336WB 400 2 SGDA+Kit
MB332 600 2 SGHA SGLA SGPA
MB332WB 600 2 SGHA+Kit
MB613 100 3 THQB THHQB
MB616 100 6 (2) THQB (2) THHQB
MB513 225 3 TQD THQD
MB516 400 6 (2) TQD (2) THQD
MB233 225 3 SFHA SFLA SFPA
MB233WB 225 3 SFHA+Kit
AQU3:
MB23325 400 65 2nd SFHA
208/120
MB2332WB5 400 65 2nd SFHA+Kit
VAC,
MB333 400 3 SGHA SGLA SGPA
3 Phase
MB331WB 400 3 SGDA+Kit
MB335WB 400 2 SGDA+Kit
MB334WB 400 3 SGDA+Kit
MB336WB 400 2 SGDA+Kit
MB333 600 3 SGHA SGLA SGPA
MB333WB 600 3 SGHA+Kit
MB423 100 3 TEY
MB426 100 6 (2) TEY
MB133 150 3 TED2 THED
MB133 150 3 SEHA SELA SEPA
MB133WB 150 3 SEHA+Kit
AEU3: MB233 225 3 SFHA4 SFLA SFPA
480/277 MB233WB 225 3 SFHA+Kit4
Vac, MB23325 400 65 2nd SFHA4
3 Phase MB2332WB5 400 65 2nd SFHA+Kit4
MB333 400 3 SGHA4 SGLA SGPA
MB334WB 400 3 SGDA+Kit
MB336WB 400 2 SGDA+Kit
MB333 600 3 SGHA4 SGLA SGPA
MB333WB 600 3 SGHA+Kit4
1Breaker not included except for WB kits (where product number ends in WB). WB kits include a breaker, mounting kit and load-side lugs. Rating plugs must be
ordered separately.
2Actual breaker rating is 18kAIC.
3Actual breaker rating is 30kAIC.
4Actual breaker rating is 35kAIC.
5To achieve 6 poles of subfeed, the MB233WB or MB233 kit is also required. 6 poles of subfeed only work with 400A and 600A interiors.

MB513 Breaker Kit MB516 6-Pole Breaker Kit MB233WB WB Breaker Kit

Rev. 11/13 www.geindustrial.com BuyLog Catalog 11-15


Data subject to change
without notice
Panelboards Section 11
A-Series II Panelboards
Pro-Stock, Unassembled Lighting Panels
5 Typical Main Breakers

Skip Step 5 if you selected a main breaker kit ending in WB All TQD and Spectra main breakers require line-side lugs.
no breaker is required. For TEY and THQB main breakers, see branch breakers tables in
To correlate breaker types with the kAIC rating in specific panel- Step 7.
boards, see the table for Step 4. For more rating details, see
A-Series II Lighting Panels Rating Series Labels (DEH-40007).
Digital, Solid State Spectra RMS Breakers (3-pole) For use with appropriate main breaker kit (see Step 4).
Breaker Rating Plug1 Terminal Lugs for Front Connection2
Current Amp Wire Range
Poles Sensor Product Number Rating Product Number Product Number (Cu/Al)
SEDA36AT0100
SEHA36AT0100
100 100 SRPE100A100
SELA36AT0100
SEPA36AT0100 TCAL18 #12-3/0
SEDA36AT0150 110 SRPE150A110
150 SELA36AT0150 125 SRPE150A125
SEPA36AT0150 150 SRPE150A150
3 70 SRPF250A70
90 SRPF250A90
100 SRPF250A100
SFHA36AT0250 110 SRPF250A110
250 SFLA36AT0250 125 SRPF250A125 TCAL29 #8-350 MCM
SFPA36AT0250 150 SRPF250A150
175 SRPF250A175
200 SRPF250A200
225 SRPF250A225
125 SRPG400A125
SGHA36AT0400
150 SRPG400A150
3 400 SGLA36AT0400
175 SRPG400A175 TCLK365
SGPA36AT0400
200 SRPG400A200
225 SRPG400A225 Al: (2) 2/0-500
SGHA26AT0400 250 SRPG400A250 MCM or (1)
2 400 SGLA26AT0400 300 SRPG400A300 TCLK265 #6-600 MCM
SGPA26AT0400 350 SRPG400A350 Cu: (2) 2/0-400
400 SRPG400A400 MCM or (1)
250 SRPG600A250 #8-600 MCM
SGLA36AT0600
3 600 300 SRPG600A300 TCLK365
SGPA36AT0600
350 SRPG600A350
400 SRPG600A400
2 600 SGLA26AT0600 500 SRPG600A500 TCLK265
SGPA26AT0600 600 SRPG600A600
1Any rating plug within a given current sensor group may be paired with any breaker in that group.
2Except for WB kits, lugs must be ordered separately for Spectra breakers. All Spectra breakers also require an appropriate rating plug.

Main or subfeed breakers for use with AQ panels (208/120 Vac 3-phase or 240 Vac single phase). See Step 4.
2-pole 3-pole
10kAIC 22kAIC 10kAIC 22kAIC
Amp Product3 Product Product3 Product
Rating Number Number Number Number
100 TQD22100X2 THQD22100X2 TQD32100X2 THQD32100X2
125 TQD22125X2 THQD22125X2 TQD32125X2 THQD32125X2
150 TQD22150X2 THQD22150X2 TQD32150X2 THQD32150X2
175 TQD22175X2 THQD22175X2 TQD32175X2 THQD32175X2
200 TQD22200X2 THQD22200X2 TQD32200X2 THQD32200X2
225 TQD22225X2 THQD22225X2 TQD32225X2 THQD32225X2
250 TJD422250L2 TJD432250L3
300 TJD422300L2 TJD432300L3
350 TJD422350L2 TJD432350L3
400 TJD422400L2 TJD432400L3

Main or subfeed breakers for use with AE panels (480/277 Vac 3-phase). See Step 4.
3-pole
18kAIC 22kAIC 30kAIC
Amp Rating Product Number Product Number Product Number
100 TED134110WL THED134110WL MB233WB
125 TED134125WL THED134125WL MB233WB
150 TED134150WL THED134150WL MB233WB
175 MB233WB
200 MB233WB
225 MB233WB
250 TJJ436250L3
300 TJJ436300L3
350 TJJ436350L3
400 TJJ436400L3
3Any load-side lugs on TQD breakers must be removed before assembly. TQD breakers with X2 product number suffix feature line-side lugs only.

11-16 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Panelboards Section 11
A-Series II Panelboards
Pro-Stock, Unassembled Lighting Panels
6 Select Main Lug Kit and Accessories
Select lug kit(s) for main lug and/or feed-thru applications, if required. (All lugs are
suitable for interiors with either copper or aluminum bus.) Also select any accessories
required.

Main Lug Kits


Standard Oversized 200% Neutral
Amp Product Product Product
Lug Type Rating Number Wire Range Number Wire Range Number
225 MLA1 6-350 MCM MLA2 1-600 MCM or (2) 1/0-250 MCM NKA
Pressure 400 MLA41 2-600 MCM or (2) 1/0-250 MCM MLA62 3/0-800 MCM NKA42
600 MLA61 (2) 2/0-500 MCM MLA62 3/0-800 MCM
225 MLR1 4-450 MCM MLR2 1-600 MCM NKR
Copper 400 MLR41 1-600 MCM MLR61 (2) 2/0-500 MCM NKR4
600 MLR61 (2) 2/0-500 MCM
225 MLT1 2/0-300 MCM MLT2 4/0-500 MCM NKT
Compression
400 MLT42 250-600 MCM MLT41 500-750 MCM1 NKT4
Dual 225 MLA2 2-600 MCM or (2) 1/0-250 MCM
Main 400 MLA61 (2) 2/0-500 MCM
1500 MCM Cu, 750 MCM Al.
2For 200% neutral feed-thru, order NKA4FT, (GO-101P). Wire range (2) 2/0 600 MCM or (4) 4-250 MCM.

Accessories
Service Entrance3 ProCare Kit4
Amp Rating Product Number Description Product Number
225A BNDKT ProCare Kit for Pro-Stock PROCARE
400A BNDKT6 panelboard installation
and maintenance
600A BNDKT6
4ProCare Kit includes: (5) filler plate hardware kits, (9) bus stud nuts, (5) MLA1 filler
3Service entrance kit includes a bonding strap with hardware and a service
entrance label. plates, (2) 225A phase barriers, (2) feed-thru barriers, (1) 400/600A phase barrier,
(50) directory cards/rating books, (50) circuit number strips (1-48), (50) circuit
number strips (43-84), (5) standard locks and keys, (50) deadfront screws, (10)
AQ/AE front hardware kits, (10) AD front hardware kits, (50) service disconnect
labels, (50) main labels.
7 Typical Bolt-On Branch Breakers
These tables show typical branch breakers, but do not include all branch breakers that can be used with Pro-Stock panelboards.
Branch circuit breakers for use with AQ panels (208/120 Vac 3-phase or 240 Vac single phase)
10kAIC 22kAIC
1-pole 2-pole 3-pole 1-pole 2-pole 3-pole
Amp Product Product Product Product Product Product
Rating Number Number Number Number Number Number
15 THQB1115 THQB2115 THQB32015 THHQB1115 THHQB2115 THHQB32015
20 THQB1120 THQB2120 THQB32020 THHQB1120 THHQB2120 THHQB32020
25 THQB1125 THQB2125 THQB32025 THHQB1125 THHQB2125 THHQB32025
30 THQB1130 THQB2130 THQB32030 THHQB1130 THHQB2130 THHQB32030
35 THQB1135 THQB2135 THQB32035 THHQB1135 THHQB2135 THHQB32035
40 THQB1140 THQB2140 THQB32040 THHQB1140 THHQB2140 THHQB32040
45 THQB1145 THQB2145 THQB32045 THHQB1145 THHQB2145 THHQB32045
50 THQB1150 THQB2150 THQB32050 THHQB1150 THHQB2150 THHQB32050
60 THQB1160 THQB2160 THQB32060 THHQB1160 THHQB2160 THHQB32060
70 THQB1170 THQB2170 THQB32070 THHQB1170 THHQB2170 THHQB32070
80 THQB2180 THQB32080 THHQB2180 THHQB32080
90 THQB2190 THQB32090 THHQB2190 THHQB32090
100 THQB21100 THQB32100 THHQB21100 THHQB32100

Branch circuit breakers for use with AE panels (480/277 Vac 3-phase)
14kAIC
1-pole 2-pole 3-pole
Product Product Product
Amp Rating Number Number Number
15 TEY115 TEY215 TEY315
20 TEY120 TEY220 TEY320
30 TEY130 TEY230 TEY330
40 TEY140 TEY240 TEY340
50 TEY150 TEY250 TEY350
60 TEY160 TEY260 TEY360
70 TEY170 TEY270 TEY370
80 TEY180 TEY280 TEY380
90 TEY190 TEY290 TEY390
100 TEY1100 TEY2100 TEY3100

Rev. 11/13 www.geindustrial.com BuyLog Catalog 11-17


Data subject to change
without notice
Panelboards Section 11
A-Series II Panelboards
Pro-Stock, Unassembled Lighting Panels
Pro-Stock Interiors Product Number Structure
Catalog Number Structure
AEU 1 18 2 RCXAX T1 B4

Interior Type
AQU 240 Vac Bus
AEU 480Y/277 Vac No. of Circuits B4 Copper
18 18 Circuits Blank Aluminum
30 30 Circuits
42 42 Circuits

Max. Amp
Phase T1 Feed-thru
Rating
1 1 Phase Blank Non Feed-thru* (requires copper bus [B4])
2 225A
3 3 Phase * For retrofit applications
4 400A
6 600A

11-18 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Panelboards Section 11
A-Series II Panelboards
Product Options

Enclosure Options

BOX EXTENSIONSFor additional end gutter space or conduit


skirt applicationssee page 11-20.

Equipment GroundsFactory Supplied with Panelboard

Description Product Number


Field installed kits
Standard bonded to box-for each 12 branch AEBG
positions TGL2
Copper bonded to box-for each 12 branch
positions TGC2
Standard-isolated/insulated-for each 12
branch positions EGS12
Copper-isolated/insulated-for each 12
branch positions EGC12
Main lug for above terminal kits TGL20

AEBGC
Optional Equipment Grounds

Description Product Number


Aluminum Extruded Bonded AEBG
Copper Extruded Bonded AEBGC
Aluminum Extruded Isolated AEIG
Copper Extruded Isolated AEIGC
Copper Isolated/Bonded ASPGIBC

THQB/THHQB/THQL/THHQL/TEY Filler Plates

Product Number
AEIG
TQLFP1

TQD/THQD/TED4/SE/FB Filler Plates

Product Number
TEDFP1

Breaker Mounting1 Hardware Kits

Description Product Number


Breaker type TED/THED4/SE ASPTED3P AEIGC
Breaker type TQD/THQD ASPTQD3P
Breaker type FBfor mounting 12 poles ASPFB12P2
Breaker type FBfor mounting 3 poles ASPFB3P3
1Use to mount breaker in existing space.
2Includes mounting screws and washers only.
3Includes screws, washers and A-Series II panelboard connectors.

ASPGIBC

Rev. 11/13 www.geindustrial.com BuyLog Catalog 11-19


Data subject to change
without notice
Panelboards Section 11
A-Series II Panelboards
Accessories
Field Installed Kits/Replacement Parts
Order By Product Number from Factory

Endwall Kits
Field installed. For standard 20"w x 5.81"d boxes.
Product Number Description Qty.
ABEW2 Blank 1
AKEW2 Knockout 1

Panelboards Parts
Product List Price,
Description Number GO-101
Directory Card 139C5612P3 $2.00 Replacement Lock with Replacement Lock with
Replacement Lock with Std. Key 569B737P1 $22.00 Standard Key Black GE75 Key Red with no
Replacement Lock with GE75 Key 569B737P2 $22.00 with GE Monogram GE Monogram
Additional Keys for Above Lock 569B737P5 $2.00
Circuit Numbering Strips- Box Extensions
1-48 569B806G1 $4.00
Bolts to A-Series II box with or without box endwall in place.
49-84 569B806G2 $4.00
Extensions can be combined to obtain lengths greater than 18
85-126 569B806G3 $4.00
and 24 inches.
Adhesive Backed Lamicoid Nameplate 3/4 in. x 3 in. 315A7190P1 $27.00
Metal Directory Card Holder 139C5491G1 $50.00 Box Width Box Extension Box Extension
and Depth Box Mounting Length (Inches) Product Number
Directory Card Holder 139C5491P4 $10.00
9 ABX2509F
Delta Hi-leg Conversion Kit, to Add B-Phase
Flush 18 ABX2518F
Plug on AL Panels APHBL $60.00
24 ABX2524F
Bolt on AE/AQ Panels APHBQ $60.00
9 ABX2509S
NEMA 3R/12 Tamper Proof Tork Screw Kit NEMATRX $30.00
18 ABX2518S
2P to 3P TQD Conv. Kit ASP2PTQD3P $100.00
24 ABX2524S
2P to 3P SF Conv. Kit for horizontal subfeed ASP2PTFJ3P $100.00
1
20 x 5.81 31 ABX2531S
AD 25 to 65 kAIC Barrier kit ASP25AD65KA $100.00
37 ABX2537S
Service Entrance Kit ASPSERENT $50.00 Surface
43 ABX2543S
2 wire Relay Kit ASP2WRelay $286.00
49 ABX2549S
Yale Lock Kit ASPYALE47 $120.00
55 ABX2555S
Corbin Lock Kit ASPCORBNTEU1 $120.00
64 ABX2564S
2-3 pole TQD Mechanical Interlock TQDFM1 $120.00
76 ABX2576S
AQ/AL/AE Rail Bracket ASPAQLEBKT $20.00
18 ABX3518F
Front Flush Adjust Kit ASPFLUSHADJ $20.00 Flush
24 ABX3524F
AE Front Mounting Kit 139C5720G3 $30.00 30 x 5.81
18 ABX3518S
AQ/AL Front Mounting Kit 139C5720G6 $30.00 Surface
24 ABX3524S
AD Front Mounting Kit 139C5720G9 $30.00
18 ABX3718F
Front Hinge to Box Mounting Kit 139C5700G6 $20.00 Flush
24 ABX3724F
Front Extension Mounting Kit 139C5700G11 $20.00 30 x 7.81
18 ABX3718S
1 Surface
Included in factory assembled panelsAD panels with Spectra 24 ABX3724S
branch breakers.

Permanent Circuit Number Kits Box Extensions Covers Only


10 covers per kit.
Product Number
AQ, AL, AE AD Description Description Product Number

APN48 APN48AD Nos 1-48 9" Covers Surface ASPABX09S


APN84 APN84AD Nos 43-84 9" Covers Flush ASPABX09F
APN126 APN126AD Nos 85-126 18" Covers Surface ASPABX18S
18" Covers Flush ASPABX18F
64" to 76" Covers Surface ASPABX20S
64" to 76" Covers Flush ASPABX20F

11-20 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Panelboards Section 11
A-Series II Power Panelboards
Features
Symmetrical design, no required top or bottom mountings
Single-piece deadfront no filler plates needed
Smaller, lighter panel than Spectra Series panelboards
Easy-to-install galvanized enclosures with removable endwalls
Ready-to-install hinged trim options
Branch-bus direct connection
Up to 600A breaker mounted as a branch device
Deeper (8"), wider (30") A-Series II box to accommodate larger
wire sizes
Double branched 150A (ED/SE) and 225A (QD) breakers
Vertically mounted main circuit breakers in 800A
Captive hardware on branch breakers
Staggered, center-mounted, larger frame breakers (SG, SF) for
easy installation
Bus-connected TVSS for maximum surge protection
Narrow design to minimize footprint
Enclosure available in NEMA Type 1, Type 3R/12, Type 4/4X

Rev. 11/13 www.geindustrial.com BuyLog Catalog 11-21


Data subject to change
without notice
Panelboards Section 11
A-Series II Power Panelboards

Type AQP Type ADP


Service Information: Service Information:
1P, 3W-240/120 Vac 1P, 3W-240/120 Vac
3P, 3W-240 Vac 3P, 3W-240 Vac
3P, 4W-208/120 Vac 3P, 4W-208/120 Vac, 480/277 Vac
Fully Rated-65kAIC at 240 Vac Fully Rated-100kAIC at 480 Vac
Series Rated-200kAIC at 240 Vac Series Rated-100kAIC at 480 Vac
Mains Mains
Breakers: Breakers:
125-800A: SG, SK 125-800A: SG, SK
Main Lug: Main Lug:
600-800A 600-800A
Branch Breakers (Bolt-on): Branch Breakers (Bolt-on):
15A-100A (1P, 2P, 3P): QB 15A-100A (1P, 2P, 3P): FB Breakers
Double Branch- TQD, SE 15A-100A (1P, 2P, 3P): THED Breakers
Center-Mounted- SF, SG 15A-150A (3P): THED Breakers
Enclosures Double Branch-TED, SE
Length-25.5, 31.5, 37.5, 43.5, 49.5, 55.5, 64.5, 76.5, 82.5, 88.5 Center-Mounted-SF, SG
Width-30 Enclosures
Depth-8 Length-25.5, 31.5, 37.5, 43.5, 49.5, 55.5, 64.5, 76.5, 82.5, 88.5
Width-30
Depth-8

Type AEP
Service Information:
1P, 3W-240/120 Vac
3P, 3W-240 Vac
3P, 4W-208/120 Vac, 480/277 Vac
Fully Rated- 18kAIC at 480/277 Vac, 65kAIC at 240Vac
Series Rated- 100kAIC at 480 Vac, 200kAIC at 240 Vac
Mains
Breakers:
125-800A: SG, SK
Main Lug:
600-800A
Branch Breakers (Bolt-on):
15A-100A (1P, 2P, 3P): TEY, TEYF
Double Branch- TED, SE
Center-Mounted-SF, SG
Enclosures
Length-25.5, 31.5, 37.5, 43.5, 49.5, 55.5, 64.5, 76.5, 82.5, 88.5
Width-30
Depth-8

11-22 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Panelboards Section 11
A-Series II Panelboards
Branch Circuit Monitoring

The Branch Circuit Monitoring (BCM) unit provides a cost-effective


integrated solution for A-Series II Panelboard power monitoring
and submetering applications. With exceptional performance, the
BCM unit monitors key electrical parameters of the main circuit
and various branch circuits coming into the panelboard. This
information can be transmitted via the RS-485 communication
system in order to analyze usage and identify potential cost
saving measures and improve load management. Offering IEC
Class 1 revenue grade metering accuracy, the revenue grade
BCM meter can be used for tenant billing and cost allocation.

Features
Solutions up to 800A
IEC Class 1 revenue grade metering accuracy
Offers Solid Core or Split Core BCM selection process
Monitor up to 50 panelboards on one RS-485 drop
Reports volts, amps, power, and energy for each circuit
Solid Core monitors 42 circuits (and optional mains)
Split Core monitors up to 66 circuits (and optional mains)
4 configurable alarm thresholds improve load management
Ability to set the orientation and numbering of the circuits
1/4 to 1251 Amp monitoring the widest range available
1-, 2-, 3-pole breaker support
5-year warranty
Modbus RTU via RS485 communications
1Must use Split Core BCM for 110A and 125A monitoring.

Solid Core available for 42 circuits only, 100A max.


Split Core available up to 66 circuits max. and up to 125A max.

References
DEA-539 for additional information
Speedi for configuration/quotation purposes

Rev. 11/13 www.geindustrial.com BuyLog Catalog 11-23


Data subject to change
without notice
Page Updated 01 / 2017

Panelboards Section 11
A-Series II Panelboard
AMP1 Integrated Power and Energy

The AMP1 Power & Energy Meter provides a cost-effective inte-


grated solution for A-Series* II panelboard power monitoring and
submetering applications. With exceptional performance, the
AMP1 monitors key electrical parameters of the main power com-
ing into the panelboard. This information can then be transmitted
to a building automation system (BAS), or similar system, to ana-
lyze usage and identify potential cost saving measures. Offering
ANSI 12.20 0.5% accuracy, the revenue grade AMP1 meter can be
used for tenant billing and cost allocation.

Features
Solutions up to 800A
Revenue Grade, ANSI 12.20 0.2% accuracy
Monitors voltage, amperage, power, and energy
Backlit LCD Display
Data logging option to ensure data is still preserved locally
Communicates via Modbus RTU or BACnet Versatile and
widely used protocols.
User-enabled password protection
UL-67 approved
5-Year warranty
Earn points towards LEED Certification

Meter
Type Product Number
Pulse AMP1B1
Modbus AMP1C2
Modbus & data logger AMP1C3
Bacnet & data logger AMP1H5

Panelboard
TYPE AQ TYPE AE TYPE AS
Max Voltage 240V 480Y/277V, 125/250 Vdc 480Y/277V, 125/250 Vdc
Max Amperage 800A 800A 800A
Fully Rated 65kAIC at 240V 18kAIC at 480Y/277V, 65kAIC at 240V 65kAIC at 480Y/277V, 100kAIC at 240V
Series Rated 200kAIC at 240V 100kAIC at 480V 100kAIC at 480V
Main Lug 600 Amp Max 600 Amp Max 600 Amp Max
Main Breakers QB, SE, SF, SG, SK TEY, TEYF, SE, SF, SG, SK TEYD/H/L, SE, SF, SG, SK
Branch Breakers 15A-100A, 1P, 2P, 3P QB 15A-100A, 1P, 2P, 3P TEY or TEYF 15A-100A, 1P, 2P, 3P TEYD/H/L

Optional Accessories
To add an AMP1 meter to an existing/non-metering panel, enclosure, CTs and fuse kit can be ordered separately.
Current Transformer1 Enclosure2 Fuse Kit3
Amp Rating Product Number AMP1N4 AMP1FUSE
100 AMP1V100A
200 AMP1V200A
300 AMP1V300A
400 AMP1V400A
600 AMP1V600A
800 AMP1V800A
1000 AMP1V1000A
1200 AMP1V1200A
2000 AMP1V2000A
1Qty 3 per meter required for three pole breaker applications; qty 2 per meter
required for two pole breaker applications.
2Qty 1 per meter required.
3Qty 1 per meter required.

11-24 BuyLog Catalog www.geindustrial.com Rev. 7/13


Data subject to change
without notice
Panelboards Section 11
Spectra Series Panelboards
MCCB and Fusible Mains and Feeders
Service Information:
600 Vac maximum
250 Vdc maximum
1ph-3w, 3ph-3w/4w
Mains:
1200 A maximum main lugs, circuit breaker, or fusible switch
Branches:
15-1200 Circuit
Breakers
30-1200 (2P, 3P) Fusible Switch
Fuse:
Not Included
Fuse Provisions:
30-600 Amp Units: Class R1
800-1200 amp units: Class L2

Features
Main bus, 250-1200 amp, copper or aluminum
Wide, easy-to-install galvanized enclosures with removable
endwalls
5 box widths simplify installation and design
Bolt On
Enclosures available in NEMA Type 1, Type 3R/12, Type 4/4X
Service Information:
Integrated TVSS for maximum surge protection 1P, 3W-600/347 Vac
Optional door-in-door or front-hinged-to-box construction 3P, 4W-600/347 Vac
Reduced density copper or aluminum bus Fully Rated- 200KAIC at 480/277 Vac
200% rated neutrals available Series Rated- 200KAIC at 480/277 Vac
Mains
Vertically mounted main circuit breakers available Breakers:
Branch-bus direct connection 250A-1200A: SF, SG, SK, FG
Captive hardware on branch breakers Branch Breakers (Bolt-on):
Front accessible main lug assembly Double Branch-SE, SF, SG, FG, FB, TEY, TEB, TQD Breakers
Center-mounted-SK Breakers
Process control unit in plug-in style
Spectra MVT breaker option for main/branch breakers Plug In
100% rated breakers available Service Information:
Individual breaker cover plates 1P, 3W-600/347 Vac
3P, 4W-600/347 Vac
Fully Rated-200KAIC at 480/277 Vac
Series Rated-200KAIC at 480/277 Vac
Mains
Breakers:
250A-1200A: SF, SG, SK, FG
Branch Breakers/Switches (Plug In):
Double Branch-SE, SF, SG, FG, FB, TEY, TEB, TQD Breakers
Center-mounted- SK Breakers
30A-1200A Fused Switches (R, J, H, K, T Fuses)

Rev. 7/13 www.geindustrial.com BuyLog Catalog 11-25


Data subject to change
without notice
Panelboards Section 11
Spectra Series Panelboards
Fusible Switches Load and Interrupting Ratings

Short Circuit RatingsFusible Switch Units (Plug-In Only) Maximum Horsepower Ratings1 ADS Fusible Switch
Maximum Volts, ac Volts, dc
Available Short-Circuit Rating
UL Amp Rating in Sym. Max. 2-Pole 3-Pole 2-Pole 2-Pole
in
Class Rating rms Amps Voltage Application Amps1 120 240 480 600 240 480 600 125 250
H 30-600 10,000 250/600 One-time general purpose With Standard Fuses
Fast-acting rejection sizing 30 1/2 1 1/2 3 3 3 5 7 1/2 2 5
J 30-600 200,000 600 mains & feeders, current limiting
60 1 1/2 3 5 10 7 1/2 15 15 5 10
50,000
100 7 1/2 10 15 15 25 30 20
K 30-600 100,000 250/600 Dual element no rejection means,
motor starting current limiting 200 15 25 30 25 50 60 40
200,000 50
400 50 100 125
Rejection means available in two forms 600 75 150 200 50
L 800-1200 200,000 600 Fast-acting mains & feeders With "Time-delay" Fuses
Time-delay motor starting 30 2 3 7 1/2 10 7 1/2 15 20 3
current limiting
60 3 10 20 25 15 30 50
100,000 Dual element rejection means, 100 15 30 40 30 60 75
R 30-600 250/600
200,000 motor starting current limiting
200 15 50 50 60 125 150
Fast-acting small physical size 400 125 250 350
T 100-600 200,000 250/600 mains & feeders, current limiting
600 200 400 500
1
Ratings are based on latest revision of the National Electrical Code
Article 430. Horsepower ratings for switches with Standard Class H
Panelboard Terminal Lugs - Main Lugs2 fuses are based on one-time fuses having minimum time-delay. When
time-delay fuses are used, the horsepower ratings are maximum for
and Neutral Incoming Lugs the switches.
Lighting Panels (A-Series II)
Panelboard Terminal Lugs (Cu-Al)
Spectra Optional Main Lug Terminations
Wire (Cu-Al) Max. # Lugs Per Phase
Max. Main Bus
Types Rating in Amps No. Per No. Per Lug Range 800A 800A
# Wires 1200A 1200A
125 1 1 #14-2/0
Per Lug 250-600A 21" 27"
225 1 1 #6-350kcmil
CU/AL Mechanical
AL 1 #4-600kcmil
AQ #6-350 kcmil 1 2 2 4
400 1 or
AE
2 1/0-250kcmil #2-500 kcmil 2 2 2 4
AD
600 1 2 2/0-500 mcm #2-600 kcmil 2 2 2 4

800 2 2 3/0-500 mcm 3/0 750 kcmil 2 2 2 4


2
Additional lug sizes available using oversize items. CU/AL Compression3
1/0 1 4 4 8
2/0 1 4 4 8

200% Neutral Lugs 3/0 1 4 4 8

125A - (2) - #142/0 4/0 1 4 4 8

225A - (2) - #6250 MCM 250 kcmil 1 4 4 8

400A - (2) - #4600 MCM 300 kcmil 1 4 4 8

600A - (4) - #4600 MCM 350 kcmil 1 4 4 8


400 kcmil 1 4 4 8
500 kcmil 1 4 4 8
Branch Neutral Lugs 600 kcmil 1 4 4 8
Small Holes #14#4 750 kcmil 1 4 4 8
Large Holes #142/0 3 Not available on 19" main lug module.

Column Type Panels


Panelboard Terminal Lugs (Cu-Al)
Wire (Cu-Al)
Max. Main Bus
Types Rating in Amps No. Per No. Per Lug Range
ALC 100 1 1 #6-2/0
AQC
AEC 225 1 1 #6-350kcmil

11-26 BuyLog Catalog www.geindustrial.com Rev. 7/13


Data subject to change
without notice
Panelboards Section 11
Spectra Series Panelboards
Fusible Switches Load and Interrupting Ratings

Spectra Series Neutral Kits


Includes mechanical lugs and bonding strap.
250 to 600A neutral kits can be converted to dual main version by doubling the main lug quantity using lug kits (see Accessories).
Main lug on neutral kit can be converted to compression main using AMKP lug kit.

Standard Neutral (Single Main Lug) 4 Dual Main Neutral 5


Product Accepts Accepts Wire Product Accepts Accepts Wire
Amps Number Wire Qty. Size (Cu/Al) Number Wire Qty. Size (Cu/Al)
2 ( Main) #2 - 600kcmil 2 ( Main) #2 - 600kcmil
16 #14 - 2/0 16 #14 - 2/0
250 ANKN400 5 #6 - 300kcmil ANKN400 5 #6 - 300kcmil
24 #14 - #4 24 #14 - #4
2 ( Main) #2 - 600kcmil 8 ( Main) #2 - 600kcmil
16 #14 - 2/0 9 #14 - 2/0
400 ANKN400 ANKN120
5 #6 - 300kcmil 10 #6 - 300kcmil
24 #14 - #4 10 #14 - #4
8 ( Main) #2 - 600kcmil 8 ( Main) #2 - 600kcmil
9 #14 - 2/0 9 #14 - 2/0
600 ANKN120 ANKN120
10 #6 - 300kcmil 10 #6 - 300kcmil
10 #14 - #4 10 #14 - #4
8 ( Main) #2 - 600kcmil 8 ( Main) #2 - 500kcmil
9 #14 - 2/0 8 #14 - 2/0
800 ANKN120 ANK800D
10 #6 - 300kcmil 10 #6 - 300kcmil
10 #14 - #4 4 #2 - 500kcmil
8 ( Main) #2 - 600kcmil 8 ( Main) #2 - 500kcmil
9 #14 - 2/0 8 #14 - 2/0
1200 ANKN120 ANK120D
10 #6 - 300kcmil 10 #6 - 300kcmil
10 #14 - #4 4 #2 - 500kcmil
4
For 3ph, 4W single-section panelboards, use a standard neutral.
5
For 3ph, 4W multi-section panelboards, use a standard neutral on the last section, and a dual main neutral on the first and middle sections.

Breaker Side Gutter Space smallest, lowest amperage furthest from the main incoming. The
spaces, if any, will follow after the breakers. All main breakers are
EY, QB EY, QB A ENCLOSURE mounted horizontally and incoming lugs are, as a standard and if
SIDE WALL
not specified, always oriented to the left gutter regardless if top
T(H)E, SE, FC, FE T(H)E, SE, FC, FE B
or bottom feed. If 2 or more large branch breakers (SK, SG single
T(H)QD T(H)QD C mounted) are supplied with the board then the factory will start
T(H)J, SF T(H)J, SF D the first breaker with the lugs to the right and the second breaker
SG, FG SG, FG
with lugs to left and will continue staggering them until all have
E
been installed. If any further clarification is needed, please con-
FE J tact your local GE representative.
T(H)J, SF F Enclosure Width
Letter Reference 27 31 36 40 44
SG, FG G
A 7.88 9.88 12.38 14.38 16.38

T(H)K, SK B 5.75 7.75 10.25 12.25 14.25


H
C 5.63 7.63 10.13 12.13 14.13
D N/A 5.50 8 10 12
E N/A N /A 6.38 8.38 10.38
ALL DIMENSIONS ARE FROM FACE OF LUG, SHOWN IN INCHES F 8.88 10.88 13.38 15.38 17.38
AND .250 Single mounted devices as branch or main G 8.13 10.13 12.63 14.63 16.63

Breakers are arranged, as a standard and if not specified, with H N/A N /A N/A 12.63 14.63

largest and highest amperage closest to main incoming and the J Breaker not available at time of printing

Rev. 7/13 www.geindustrial.com BuyLog Catalog 11-27


Data subject to change
without notice
Panelboards Section 11
Spectra Series Panelboards
Merchandisable Kits and Sizing Information

Spectra Series Type ANKN/ANK/ANKT Neutral Kits


Amps (N = Neutral, GF = Ground Fault) Box Width Main Lug Type Ground Fault Product Number
27-36" Single/Dual Mechanical No ANKN4001
27-36" Single Mechanical No ANK2502
250A Single & Dual 27-36" Dual Mechanical No ANK250D2
36" Single Crimp Main & Feeders No ANK250C
36" Dual Crimp Main & Feeders No ANK250DC
36" Single/Dual Mechanical No ANKN1201
250A 200%N 36" Single Mechanical No ANKT362502
36" Dual Mechanical No ANKT36250D2
27-44" Single Mechanical No ANKN4001
27-44" Single Mechanical No ANK4002
27-44" Single Mechanical No ANKCU4004
400A Single & Dual 27-44" Dual Mechanical No ANKN1201
27-44" Dual Mechanical No ANK400D2
36-44" Single Crimp Main & Feeders No ANK400C
36-44" Dual Crimp Main & Feeders No ANK400DC
27-44" Single Mechanical Yes ANK400GF
400A GF
36-44" Single Crimp Main, Mech. Feeders Yes ANK400GFCM
36-44" Single/Dual Mechanical No ANKN1201
36" Single Mechanical No ANKT364002
40" Single Mechanical No ANKT404002
400A 200%N 44" Single Mechanical No ANKT444002
36" Dual Mechanical No ANKT36400D2
40" Dual Mechanical No ANKT40400D2
44" Dual Mechanical No ANKT44400D2
27-44" Single/Dual Mechanical No ANKN1201
27-44" Single Mechanical No ANK6002
600A Single & Dual 27-44" Dual Mechanical No ANK600D2
36-44" Single Crimp Main & Feeders No ANK600C
36-44" Dual Crimp Main & Feeders No ANK600DC
600A GF 27-44" Single Mechanical Yes ANK600GF
36-44 Single Mechanical No ANKN1201
36" Single Mechanical No ANKT366002
40" Single Mechanical No ANK406002
600A 200%N 44" Single Mechanical No ANK446002
36" Dual Mechanical No ANKT36600D
40" Dual Mechanical No ANKT40600D
44" Dual Mechanical No ANKT44600D
31-44" Single Mechanical No ANKN1201
31-44" Single Mechanical No ANK8002
800A Single & Dual 31-44" Dual Mechanical No ANK800D3
36-44" Single Crimp Main & Feeders No ANK800C
36-44" Dual Crimp Main & Feeders No ANK800DC3
31-44" Single Mechanical Yes ANK800GF3
800A GF
36-44" Single Crimp Main & Feeders Yes ANK800GFC3
36" Single Mechanical No ANKT368003
40" Single Mechanical No ANKT408003
44" Single Mechanical No ANKT448003
800A 200%N
36" Dual Mechanical No ANKT36800D3
40" Dual Mechanical No ANKT40800D3
44" Dual Mechanical No ANKT44800D3
31-44" Single Mechanical Yes ANK100GF3
1000A GF
36-44" Single Crimp Main & Feeders Yes ANK100GFC3
31-44" Single Mechanical No ANKN1201
31-44" Single Mechanical No ANKNCU1204
31-44" Single Mechanical No ANK1202
1200A Single & Dual 31-44" Dual Mechanical No ANK120D3
31-44" Dual Mechanical No ANKNCU120D4
36-44" Single Crimp Main & Feeders No ANK120C
36-44" Dual Crimp Main & Feeders No ANK120DC3
31-44" Single Mechanical Yes ANK120GF3
1200A GF
36-44" Single Crimp Main & Feeders Yes ANK120GFC3
36" Single Mechanical No ANKT361203
40" Single Mechanical No ANKT401203
44" Single Mechanical No ANKT441203
1200A 200%N
36" Dual Mechanical No ANKT36120D3
40" Dual Mechanical No ANKT40120D3
44" Dual Mechanical No ANKT44120D3
1Wire range #2AWG through 600 kcmil.
2Wire range above 600 kcmil.
3These neutrals require the 29 inch A gutters in the 75" and 96" high enclosures (75 High-23X or 96 High-38X)
4Material = Copper main lugs, copper feeder.

Product Number Selection Instructions: See page 11-13

11-28 BuyLog Catalog www.geindustrial.com Rev. 7/13


Data subject to change
without notice
Panelboards Section 11
Spectra Series Panelboards
Terminal Lugs

Spectra Series Main Lugs Top or Bottom Feed 240 Vac and 600 Vac, 200-1200 Amperes
Main Lug Kits (Factory Installed and/or Merchandise Panelboards)
Kit bolts directly to interior bus bars (either APN Plug-In Style or APNB Bolt-On Style).
Can be used for feed-through lug application by replacing standard cover plate with AFL feed-through cover plate kit (See
Accessories).
F suffix indicates all AFPML cover plates are included to fit applicable box widths. If cover plates are not necessary, remove the F suffix.
For 2 pole applications, replace the third digit or numeral 3 in the product number with the number 2.
Aluminum mechanical lugs can be converted to copper by replacing the first from last digit from an A to a C.

Standard Main Lug Kit (Mechanical Lugs)


Cover Plate
Module Lugs. Wires Kit Included Min.
Main Single or Dual X Product Incl. Per Per Wire Range Product Box
Amps Configuration Height Number Phase Lug (Cu/Al1 ) Number Width

250 Single & Dual 4X AMB3600MAF 1 2 8-500kcmil(1) AFPML4X 27"


2/0-600kcmil(1)

Single 4X AMB3600MAF 1 2 8-500kcmil(1) AFPML4X 27"


400 2/0-600kcmil(1)
Dual 4X AMB3120MAF 1 4 2/0-600kcmil(4) AFPML4X 27"

Single 4X AMB3600MAF 1 2 8-500kcmil(1) AFPML4X 27"


600 2/0-600kcmil(1)
Dual 4X AMB3120MAF 1 4 2/0-600kcmil(4) AFPML4X 27"
Single 4X AMB3120MAF 1 4 2/0-600kcmil(4) AFPML4X 31"
800
Dual 4X AMB3120DMAF 1 8 2/0-600kcmil(8) AFPML4X 36"
Single 4X AMB3120MAF 1 4 2/0-600kcmil(4) AFPML4X 31"
1200
Dual 4X AMB3120DMAF 1 8 2/0-600kcmil(8) AFPML4X 36"
1
Copper lugs can only be used with copper wire .

Compression Main Lug Kit


Cover Plate
Module Lugs. Wires Kit Included Min.
Main Single or Dual X Product Incl. Per Per Wire Range Product Box
Amps Configuration Height Number Phase Lug (Cu/Al) Number Width
Single 6X AMB3250CAF 1 2 350 kcmil AFPML6X 36"
250
Dual 6X AMB3250DCAF 2 1 350 kcmil AFPML6X 36"
Single 6X AMB3600CAF 2 1 500 kcmil AFPML6X 36"
400
Dual 6X AMB3600DCAF 4 1 500 kcmil AFPML6X 36"
Single 6X AMB3600CAF 1 2 500 kcmil AFPML6X 36"
600
Dual 6X AMB3600DCAF 4 1 500 kcmil AFPML6X 36"
Single 6X AMB3800CAF 3 1 500 kcmil AFPML6X 36"
800
Dual 6X AMB3800DCAF 6 1 500 kcmil AFPML6XW 36"
Single 6X AMB3120CAF 4 1 500 kcmil AFPML6X 36"
1200
Dual 6X AMB3120DCAF 8 1 500 kcmil AFPML6XW 36"

Provisional Main Lug Kit


Module Cover Plate Min.
Main Single or Dual X Product Max. Wires Kit Included Box
Amps Configuration Height Number Per Phase Product Number Width
Single 6X AMB3120NF 4 AFPML6X 36"
250
Dual 6X AMB3120NF 4 AFPML6X 36"
Single 6X AMB3120NF 4 AFPML6X 36"
400
Dual 6X AMB3120NF 4 AFPML6X 36"
Single 6X AMB3120NF 4 AFPML6X 36"
600
Dual 6X AMB3120NF 4 AFPML6X 36"
Single 6X AMB3120NF 4 AFPML6X 36"
800
Dual 6X AMB3120DNF 8 AFPML6XW 36"
Single 6X AMB3120NF 4 AFPML6X 36"
1200
Dual 6X AMB3120DNF 8 AFPML6XW 36"

Rev. 7/13 www.geindustrial.com BuyLog Catalog 11-29


Data subject to change
without notice
Panelboards Section 11
Spectra Series Panelboards
PCU Selection
Order from the Customer Service Center
Available in Spectra Plug-in Only

Spectra Series PCU Selection Guide Spectra PCU Control Power Transformer Kits
(Ref DET-104) Specify Overload Relay Amps One kit required per panel unless an external, 120VAC is brought
(Included w/PCU) into the panel.
Description: 15hp max, 22A, 600V max Continuous Primary
Configuration: 3PH, 3W, & ground; all units are 4X height, 120V kVA Voltage 2 Capacity Product Number
control. .200 600 Standard APCUCKA200

Pilot Device Mount Product Number1 .300 600 Extra APCUCKA300


.200 480/240 Standard APCUCKB200
Yes Double APCU151FNDPD**
.300 480/240 Extra APCUCKB300
Yes Single APCU151FNDPSX*
.200 208 Standard APCUCKC200
No Double APCU151FNDND**
.300 208 Extra APCUCKC300
No Single APCU151FNDNSX*
2
1Replace * with required overload range from table. Secondary voltage is 120Vac.

PCU Overload Selection

* Overload Range
B 0.16-0.26A
C 0.25-0.41A
D 0.40-0.65A
F 0.65-1.1A
G 1.0-1.5A
H 1.3-1.9A
J 1.8-2.7A
K 2.5-4.1A
L 4.0-6.3A
M 5.5-8.5A
N 8.0-12.0A
P 10.0-16.0A
S 14.5-18.0A
T 17.5-22.0A
X BLANK

Spectra PCU Kits


Description Product Number

Spectra PCU Pilot Light Option APCUKPLT


(Kit includes red and green pilot lights)
Spectra PCU Wiring Kit (Optional kit for remote wiring) APCUWK
APCUEKAF (left side)
Spectra PCU Expansion Kit to expand or rebuild PCU units)
APCURKAF (right side)

Spectra PCU Blank Cans 4X APCUDCAN4X


(Provides space for future PCU starters, other devices) 7X APCUDCAN7X

Product Number Selection Instructions: See page 11-13

11-30 BuyLog Catalog www.geindustrial.com Rev. 7/13


Data subject to change
without notice
Panelboards Section 11
Spectra Series Panelboards
Interior, Enclosure Options

Bus Bars Equipment Ground Bars


Spectra grounding kits are sized according to the number of
Description
panel circuits (one per circuit or space).
Copper 1000 Amp/sq-in. Main Vertical Bus
Silver plated copper in lieu of silver Description
plated aluminum Bondable to boxincludes bonding strap and main terminal
Insulated/isolatedincludes main terminal
Aluminum 600 Amp/sq-in. Main Bus Density

Reduces current density from


750 amps/sq-in. to 600 amps/sq-in. Enclosures (Box)
Copper 800 Amp/sq-in. Main Bus Density Description
Reduces current density from Painted/Increased Gage
1000 amps/sq-in to 800 amps/sq-in.
One option provides 12 gage box painted
ANSI 61 gray (not available separately)
NEMA 3R
NEMA 12
Locking Devices NEMA 4X Stainless Steel
Wide Box (increased gutter space)
Product
Frame Style Description Number To increase to 31" from 27" box
Padlocking Device (single padlock) To increase to 36" from 31" box
Q1 THQB, THHQB THP100 To increase to 44" from 40" box
E TEY TEYPLD1 To increase to 44" from 36" box

FC FCS, FCV, FCN, Narrow Box 4


FCPLD
FCH, FCL, FCPF
To decrease to 27" from 36" box (circuit breakers only)
TEB, TED, THED TEFPLD1
SE, E To decrease to 36" from 44" box
SED, SEH, SEL, SEP SEPLD
Box skirt 12" high
FE FES, FEV, FEN, Breaker not available
FEH, FEL, FEPF at time of printing Touch-up Paint
ANSI 61 gray, 12 oz. can
QD TQD, THQD TQDPLD1
4
Narrow box option limited to panels with maximum 600-amp circuit
SF, F SFH, SFL, SFP SEPLD
breaker feeders and 400-amp fusible feeders with T or J fuse clips. This
SG SGD, SGH, SGL, SGP SGPLD option single branches some double branched devices and may result in
additional sections. See page 3-34 and 3-35 for sizing information.
FG FGV, FGN, FGH,
FGL, FGP, FGPF FGPLD

SK, K SKH, SKL, SKP SKPLD Fronts


Handle Locking (nonpadlocking)

Q1 THQB, THHQB THL103 27" 31" 36" 40" 44"


Standard
E TEB, TED, THED TLD3 Arrangement 4 piece surface only (no door)
1
Not available for ground fault breakers. Optional regular door
(27W, surface only)
5,6
Optional door
within a door front
Locking Devices EUSERC ApprovedFactory Installed Only Optional front hinged
to box surface only
Breaker Type Product Number
5
Specify surface or flush.
TQD TQDPLD2 6
Not available in 27" wide.
FC FCS, FCV, FCN,
FCH, FCL, FCPE
E150 TEDPLD2 Front Modifications
SE150, SF250 2 SEFPLD2
FES, FEV, FEN,
FE
FEH, FEL, FEPE Description

SG600 SGPLD2 Lexan Cardholder for fronts with doors


Lamicoid Nameplate (1 per panel)
FG FGV, FGN, FGH,
FGL, FGP, FGPE Yale 511S Spring Bolt Lock with Rosette Sleeve
J600 TJKPLD2 Corbin 15767 Latch Bolt
SK1200 SKPLD2 3 pt Catch and Vault Handle
2 Permanent Number Tabs #1-49
Field Installable
Permanent Number Tabs #1-99

Rev. 7/13 www.geindustrial.com BuyLog Catalog 11-31


Data subject to change
without notice
Panelboards Section 11
Spectra Series Panelboards

TVSS (Transient Voltage Surge Suppression)


Surge Current
Product Panel X Panel Capability
Number System Voltage Width Height Type (per mode)

120/208V, 240V 65ka


Delta, 120/240V
ATME 27" - 44" 7X Plug-in/
Delta, 120/240V
Bolt-on
Delta, 277/480V,
80ka
480V Delta

120/208V, 240V 100ka


Delta, 120/240V
ATHE 27" - 44" 7X Plug-in/ 150ka
Delta, 120/240V
Bolt-on
Delta, 277/480V,
480V Delta 200ka

*Field installable kits are available for adding to existing boards.


*Kits include: TVSS unit, 3 cover sizes, cover mounting brackets and cable.
*Add a K to the end of the full Product Number for the kit number.

Energy Management Meters


Product System Phase/ Ship
Number Voltage Wire Cycle

EPM2200/ 600/347V 3P 4W/3P 3W


EPM6000/ 480V 3P 4W/3P 3W N
EPM7000
208/120V 3P 4W
600/347V 3P 4W/3P 3W
480V 3P 4W/3P 3W
PQM Meter
240V 3P 3W N
Module
240/120V HI-Leg 3P 4W
208/120V 3P 4W
600/347V 3P 4W/3P 3W
480V 3P 4W/3P 3W
PQMII Meter
240V 3P 3W N
Module
240/120V HI-Leg 3P 4W
208/120V 3P 4W

7X required for panel distribution section mounting


Fits in 27", 31", 36", 40" and 44" wide sections

Product Number Selection Instructions: See page 11-13

11-32 BuyLog Catalog www.geindustrial.com Rev. 7/13


Data subject to change
without notice
Panelboards Section 11
Spectra Series Panelboards
Integrated Submetering Panelboard

Submetering lets you measure and bill energy use (electrical,


water, gas) in master-metered commercial and/or residential
buildings. Suitable for either new construction or retrofit, the
Spectra Series Integrated Submetering Panelboard combines
the benefits of a multi-tenant digital meter with a reliable GE
Spectra Series panelboard.

Save Valuable Real Estate


GEs fully-integrated solution maximizes valuable real estate by
combining meters, current transformers, communications and
overload protection into a single UL Listed, factory-assembled
panel. It requires only a fraction of the space needed for
traditional modular metering.

Lower Construction Costs


Because this panelboard requires no special communications Specifications
Panel Type Spectra Bolt-On (SBO)
wiring, youll reduce wire, conduit and installation costs. Individual
Certifications UL, cUL
branch circuit readings communicate through power line com- Services 1P3W, 3P3W, 3P4W
munication. All in all, its lighter, more flexible, faster and easier to Voltages 120/240V, 120/208V, 480/277V
Main Amps 250, 400, 600, 800, 1200
install than conventional utility metering. Main Types SF, SG, SK
Busing Cu
Feeder Types TED, TQD, THQD, SE, SF
Save Time Feeder Amps 15-250A
Max Fully Rated
Fully assembled and wired in the factory. AIC Ratings
65kAIC

Branch Devices 24-2 pole max.; 18-3 pole max.


No. of Meter
Features and benefits 6, 9, 12, 15, 18, 21, 24
Points/Panel
Series Ratings 65kAIC
Factory assembled/wired internal meters minimize installation Meter Specifications Per EPM 4000 Brochure
labor
Factory installed/wired CTs eliminate lengthy wiring runs and
wiring errors Typical Dimensions
Small footprint takes up less wall space than separate panels and Tenants Panel Dimensions (inches)
meters 6 65H x 40W x 11.5D
UL Listed 12 76H x 40W x 11.5D
18/24 89H x 44W x 11.5D
Communication:
Power line communication standard on all meters
Optional Modbus RS-485 communication
Up to 48 pulse inputs to capture energy data from other pulse- Example of 6-unit Wiring Diagram
type energy devices (water, gas, steam meters)
IEC optical front panel interface for programming A B C
Real-time, per-phase viewing of voltage, current, power factor,
phase angle, watts, VARs, VA and frequency
Event reporting with time and date stamps
Local LCD display
Push-button scroll
32-digit liquid crystal display (16 digit x 2 rows)
Programmable display scroll and decimal place display
Meets ANSI C12.1 and C12.16 revenue certifiable accuracy
specifications and Canada (AE-1148)
Data can be accessed and collected through third party read- GE Multipoint
bill-collect service or, with Modbus option, the internal EPM Meter
4000 platform utilizes GEs Energy Aggregator billing software,
an ideal web-based solution for tracking and monitoring energy
consumption. Energy Aggregator allows for the creation of utility
rate structures and automatic billing generation.

Rev. 7/13 www.geindustrial.com BuyLog Catalog 11-33


Data subject to change
without notice
Panelboards Section 11
Spectra Series Panelboards
Renewal Parts
Modular Concept
Order all components from Customer Service Center
Fig. 1.1 is a front view of a typical Spectra Series fusible panelboard.
Fig. 1.2 is also a front view, but with the front (4 piece trim), all fusible switches, and all filler plates removed.

Main Lug Front (4 pc) Box Interior Neutral


Module

Side Filler Plate

Full Filler Plate Ground

Fusible Switch (one side blank) Note: Incoming conduit location


should be in top or bottom
ends of enclosure. Must avoid
Fusible Switch (Branch) conduit entrances that would
interfere with ground and
neutral assembly location.

Fig. 1.1 Fig. 1.2

Product Number Selection Instructions: See page 11-13

11-34 BuyLog Catalog www.geindustrial.com Rev. 7/13


Data subject to change
without notice
Panelboards Section 11
Spectra Series Panelboards
Renewal Parts
Circuit Breaker Sizing

2P 2P
TQD, THQD,
3P 3P TEB, TED

2P 2P THQB, THHQB,
TEY, THLC1,
THED, SE-Frame,
3P 3P FC (FE Future)

TFJ, TFK, THFK,


2P or 3P SF-Frame,
27" W (FE Future)

2P or 3P SG-Frame,
FG

THLC2, THLC4
2P or 3P

2P or 3P TJD, TJJ, TJK,


THJK

2P 2P SF-Frame, TFJ,
TFK, THFK
31" W
3P 3P

SF-Frame Double,
2P 2P FC (FE Future),
Branch Adjacent
to Switch

3P 3P
SF-Frame Single,
36" W Branch or Main
Adjacent to Switch
2P or 3P

THLC2, THLC4
3P 3P

3P 3P
SG-Frame
40" W FG
2P or 3P
TKM, THKM,
SKHA, SKLA

3P 3P TJD, TJJ, TJK,


THJK
44" W
SKPA
2P or 3P

Rev. 7/13 www.geindustrial.com BuyLog Catalog 11-35


Data subject to change
without notice
Panelboards Section 11
Spectra Series Panelboards
Replacement Boxes and Fronts
Order from the Customer Service Center

Type APB NEMA 1 Enclosure Type APB NEMA 1 Enclosure (Continued)


Interior Product Interior Product
Width Height X-Height Modification Number Width Height X-Height Modification Number
11.50"D, Std Gauge APB2765AS 11.50"D, Std Gauge APB3665
11.50"D, Painted/Heavy Gauge APB2765ASP 18X, 23X, 11.50"D, Painted/Heavy Gauge APB3665P
18X 65
14.25"D, Std Gauge APB2765A 28X 16.25"D, Std Gauge APB3665D
14.25"D, Painted/Heavy Gauge APB2765AP 16.25"D, Painted/Heavy Gauge APB3665DP
11.50"D, Std Gauge APB2765BS 11.50"D, Std Gauge APB3675
11.50"D, Painted/Heavy Gauge APB2765BSP 11.50"D, Painted/Heavy Gauge APB3675P
65" 23X 75" 23X, 28X
14.25"D, Std Gauge APB2765B 16.25"D, Std Gauge APB3675D
14.25"D, Painted/Heavy Gauge APB2765BP 16.25"D, Painted/Heavy Gauge APB3675DP
36"
11.50"D, Std Gauge APB2765CS 11.50"D, Std Gauge APB3689
11.50"D, Painted/Heavy Gauge APB2765CSP 11.50"D, Painted/Heavy Gauge APB3689P
27" 28X 89" 33X, 38X
14.25"D, Std Gauge APB2765C 16.25"D, Std Gauge APB3689D
14.25"D, Painted/Heavy Gauge APB2765CP 16.25"D, Painted/Heavy Gauge APB3689DP
11.50"D, Std Gauge APB2775S 11.50"D, Std Gauge APB3696
11.50"D, Painted/Heavy Gauge APB2775SP 38X, 43X, 11.50"D, Painted/Heavy Gauge APB3696P
75" 28X 96"
14.25"D, Std Gauge APB2775 48X 16.25"D, Std Gauge APB3696D
14.25"D, Painted/Heavy Gauge APB2775P 16.25"D, Painted/Heavy Gauge APB3696DP
11.50"D, Std Gauge APB2789S 11.50"D, Std Gauge APB4065
11.50"D, Painted/Heavy Gauge APB2789SP 11.50"D, Painted/Heavy Gauge APB4065P
89" 33X, 38X 65" 18X, 23X
14.25"D, Std Gauge APB2789 14.25"D, Std Gauge APB4065D
14.25"D, Painted/Heavy Gauge APB2789P 14.25"D, Painted/Heavy Gauge APB4065PD
11.50"D, Std Gauge APB3165A 11.50"D, Std Gauge APB4075
11.50"D, Painted/Heavy Gauge APB3165AP 11.50"D, Painted/Heavy Gauge APB4075P
18X 75" 23X, 28X
14.25"D, Std Gauge APB3165AD 14.25"D, Std Gauge APB4075D
14.25"D, Painted/Heavy Gauge APB3165ADP 14.25"D, Painted/Heavy Gauge APB4075DP
40"
11.50"D, Std Gauge APB3165B 11.50"D, Std Gauge APB4089
11.50"D, Painted/Heavy Gauge APB3165BP 11.50"D, Painted/Heavy Gauge APB4089P
65" 23X 89" 33X, 38X
14.25"D, Std Gauge APB3165BD 14.25"D, Std Gauge APB4089D
14.25"D, Painted/Heavy Gauge APB3165BDP 14.25"D, Painted/Heavy Gauge APB4089DP
11.50"D, Std Gauge APB3165C 11.50"D, Std Gauge APB4096
11.50"D, Painted/Heavy Gauge APB3165CP 38X, 43X, 11.50"D, Painted/Heavy Gauge APB4096P
28X 96"
14.25"D, Std Gauge APB3165CD 48X 14.25"D, Std Gauge APB4096D
14.25"D, Painted/Heavy Gauge APB3165CDP 14.25"D, Painted/Heavy Gauge APB4096DP
11.50"D, Std Gauge APB3175 11.50"D, Std Gauge APB4465
11.50"D, Painted/Heavy Gauge APB3175P 11.50"D, Painted/Heavy Gauge APB4465P
31" 75" 23X, 28X 65" 18X, 23X
14.25"D, Std Gauge APB3175D 16.25"D, Std Gauge APB4465D
14.25"D, Painted/Heavy Gauge APB3175DP 16.25"D, Painted/Heavy Gauge APB4465DP
11.50"D, Std Gauge APB3189 11.50"D, Std Gauge APB4475
11.50"D, Painted/Heavy Gauge APB3189P 11.50"D, Painted/Heavy Gauge APB4475P
89" 33X, 38X 75" 23X, 28X
14.25"D, Std Gauge APB3189D 16.25"D, Std Gauge APB4475D
14.25"D, Painted/Heavy Gauge APB3189DP 16.25"D, Painted/Heavy Gauge APB4475DP
44"
11.50"D, Std Gauge APB3196A 11.50"D, Std Gauge APB4489
11.50"D, Painted/Heavy Gauge APB3196AP 11.50"D, Painted/Heavy Gauge APB4489P
38X, 43X 89" 33X, 38X
14.25"D, Std Gauge APB3196AD 16.25"D, Std Gauge APB4489D
14.25"D, Painted/Heavy Gauge APB3196ADP 16.25"D, Painted/Heavy Gauge APB4489DP
96"
11.50"D, Std Gauge APB3196B 11.50"D, Std Gauge APB4496
11.50"D, Painted/Heavy Gauge APB3196BP 38X, 43X, 11.50"D, Painted/Heavy Gauge APB4496P
48X 96"
14.25"D, Std Gauge APB3196BD 48X 16.25"D, Std Gauge APB4496D
14.25"D, Painted/Heavy Gauge APB3196BDP 16.25"D, Painted/Heavy Gauge APB4496DP

Product Number Selection Instructions: See page 11-13

11-36 BuyLog Catalog www.geindustrial.com Rev. 7/13


Data subject to change
without notice
Panelboards Section 11
Spectra Series Panelboards
Replacement Boxes and Fronts
Order from the Customer Service Center

Type APB NEMA 3R and 12 Enclosures


Interior
Width Depth Height X-Height1 Product Number2
18X APB(D,R)276518(B,T)
65" 23X APB(D,R)276523(B,T)
28X APB(D,R)276528(B,T)
27" 14.25"
75" 28X APB(D,R)277528(B,T)
89" 33X APB(D,R)278933(B,T)
38X APB(D,R)278938(B,T)
18X APB(D,R)316518(B,T)
65" 23X APB(D,R)316523(B,T)
28X APB(D,R)316528(B,T)
23X APB(D,R)317523E(B,T)
31" 14.25"
75" 23X GF APB(D,R)317523E(B,T)
28X APB(D,R)317528(B,T)
33X APB(D,R)318933(B,T)
89"
38X APB(D,R)318938(B,T)
18X APB(D,R)366518(B,T)
65" 23X APB(D,R)366523E(B,T)
28X APB(D,R)366528(B,T)
23X APB(D,R)367523E(B,T)
36" 16.25"
75" 23X DM APB(D,R)367523E(B,T)
28X APB(D,R)367528(B,T)
33X APB(D,R)368933(B,T)
89"
38X APB(D,R)368938(B,T)
18X APB(D,R)406518(B,T)
65"
23X APB(D,R)406523(B,T)
40" 14.25" 23X APB(D,R)407523E(B,T)
75" 23X DM APB(D,R)407523E(B,T)
28X APB(D,R)407528(B,T)
18X APB(D,R)446518(B,T)
65"
23X APB(D,R)446523(B,T)
44" 16.25" 23X APB(D,R)447523(B,T)
75" 23X DM APB(D,R)447523E(B,T)
28X APB(D,R)447528(B,T)
1GF = Ground Fault
DM = Dual Main, Ground Fault, 200% Neutral
2(D,R) D = NEMA 12
R = NEMA 3R
(B,T) B = Bottom Feed
T = Top Feed

200% Neutral
Provides second neutral assembly of equal amperage rating.

Compression Lugs
Main Lugs, Neutral Lugs and Fusible Switches
The standard sizes and number of mechanical lugs are shown on
page 11-29.

Description Description
#12 1/0 500 kcmil
2/0-300 kcmil 600-750 kcmil

Rev. 7/13 www.geindustrial.com BuyLog Catalog 11-37


Data subject to change
without notice
Panelboards Section 11
Spectra Series Panelboards
Renewal Parts
Product Number Structure

Panelboard Interior Type APN

Example: APN 38 06 U B4
X Hgt of
Interior Ampere Rating Interior Type Modification Code
18 = 18X 02 = 200A U = Unassembled Blank = Standard
23 = 23X 04 = 400A (Aluminum Bus)
28 = 28X 06 = 600A B4 = Copper Bus
33 = 33X 08 = 800A (100A/sq in.)
38 = 38X 12 = 1200A
43 = 43X
48 = 48X
53 = 53X

Panelboard Interior Type APNB

Example: APNB 38 06 U B4
X Hgt of
Interior Ampere Rating Interior Type Modification Code
18 = 18X 02 = 200A U = Unassembled Blank = Standard
23 = 23X 04 = 400A (Aluminum Bus)
28 = 28X 06 = 600A B4 = Copper Bus
33 = 33X 08 = 800A (100A/sq in.)
38 = 38X 12 = 1200A
43 = 43X
48 = 48X
53 = 53X

Panelboard Box Type APB

Example: APB 36 89
Box Box
Width Height Modification Code
27 = 27" 65 = 65" Blank = Any box except APB2765
36 = 36" 75 = 75" A = For APB2765 with 18X interior
44 = 44" 89 = 89" B = For APB2765 with 23X interior
96 = 96" C = For APB2765 with 28X interior
Panelboard Front Type APF

Example: APF 89 38
Box X Hgt of
Height Interior Modification Code
65 = 65" 18 = 18X Blank = For Std Box (36" wide)
75 = 75" 23 = 23X S = For Slim Box (27" wide)
89 = 89" 28 = 28X W = For Wide Box (44" wide)
96 = 96" 33 = 33X E = Extra Line Gutter Space for
38 = 38X Dual Main Neutral
43 = 43X N = Nonvented Front
48 = 48X (for 250A only)
53 = 53X

Product Number Selection Instructions: See page 11-13

11-38 BuyLog Catalog www.geindustrial.com Rev. 7/13


Data subject to change
without notice
Panelboards Section 11
Spectra Series Panelboards
Renewal Parts
Product Number Structure (Continued)

Disconnect Switches Type ADS

Example: ADS 3 6 200 H D FP


No. of
Poles Voltage Rating Ampere Rating Fuse Type Unit Type Accessory Code
2 = 2 poles 2 = 240V 030 = 30A H = Class H, D = Double Unit FP = With Filler
3 = 3 poles 6 = 600V 060 = 60A R, or K with 2 switches Plate Kit
100 = 100A T = Class T S = Single Switch (side fillers)
200 = 200A J = Class J in a Double Unit
400 = 400A L = Class L B = Single Branch Unit
600 = 600A M = Main Switch
800 = 800A K = Expansion Kit
120 = 1200A (switch only . . .
no module)

Circuit Breaker Mounting Modules Type AMC

Example: AMC 6 EB S FP
No. of Total CB Poles
on Module Breaker Frames Unit Type Accessory Code
6 = 6 poles QB = THQB, THHQB Blank = Std. FP = With Filler Plate Kit
(3-pole breakers, EY = TEY S = Special Type to allow (full width plates with
double branched) EB = TEB, TED, THED, SED, TFL, SE and SF to be cutouts for handles,
4 = 4 poles SEH, SEL, SEP mounted adjacent to etc.)
(2-pole breakers, FDB = FC a switch
double branched) FEB = FE Future
3 = 3 poles FJ = TFJ, TFK, THFK, TFL,
(3-pole breakers, SFH, SFL, SFP
single branched) JK = TJD, TJJ, TJK, THJK,
2 = 2 poles TJ4V, TJL4V
(2-pole breakers, LB = TLB4, THLC2, THLC4
single branched) GB or GM = SGD, SGH, SGL, SGP
FGB = FG
KM = TKM, THKM, TK4V, TKL4V,
SKH, SKL, SKP
FB = FB

Bolt-on Strap Kits Type AMCB

Example: AMCB 6 EB B FP

Poles C/B Frame Mounting Accessory Code


2 EB = SE, TEB, T(H)ED Blank = Main or Branch FP = With Filler
3 EY = TEY B = Branch Only Plate Kit
4 FDB = FC M = Main Only (full width
6 FE = FEB Future plates with
FJ = SF cutouts for
G = SG handles, etc)
FG = FGB
K = SK, T(H)KM
LB = THLC2,4
QD = T(H)QD
SE = SE, THED

Rev. 7/13 www.geindustrial.com BuyLog Catalog 11-39


Data subject to change
without notice
Panelboards Section 11
Spectra Series Panelboards
Renewal Parts
Product Number Structure (Continued)

Neutral Kits Type ANK

Example: ANK 800 D


Ampere
Rating Modification Code
250 = 250A Blank = Std (single main)
400 = 400A D = Dual Main
600 = 600A GF = Ground Fault Only
800 = 800A
100 = 1000A
120 = 1200A

Equipment Ground Kits Type AEG

Example: AEG 21 S
No. of
Circuits Modification Code
10 Blank = Std (bonded)
21 S = Insulated/Isolated
31

NEMA 1 Box Extensions - Type APB1


Example: APB 27 E

Width Extension Depth

27 E = 12H, 11.5D, 31/36/40/44W


31 12H, 14.25D, 27W
36 ED = 12H, 14.25D, 31/40W
40 12H, 16.25D, 36/44W
44 ES = 12H, 11.5D, 27W
1Note: Available in SPEEDI under EXT code on modifications screen. Also available by product number through ONE STOP.

Product Number Selection Instructions: See page 11-13

11-40 BuyLog Catalog www.geindustrial.com Rev. 7/13


Data subject to change
without notice
Panelboards Section 11
Spectra Series Panelboards
Renewal Parts
Mounting Hardware
Order from the Customer Service Center

Product Features
Use to mount main or branch circuit breakers into panelboard. Breakers bolt on to the mounting modules.
FP suffix indicates that all AFP filler plates, with cutouts for handles, are included to fit all applicable box widths. On double branch modules,
filler plates to cover any unused breaker poles are also included.
Circuit breakers not included in module price.
Includes all necessary hardware.

Circuit Breaker Mounting Modules Plug-In Spectra 3-pole


Mounting Maximum Breaker Breaker X Filler Plate Kit Box Product
Arrangement Amperage Frame Height Product Number Width Range Number
Double Branch 100 THQB or THHQB 3X AFP3QBD 27", 31", 36" 40", 44" AMC6QBFP
Double Branch 100 TEY 3X AFP3EYD 27", 31", 36" 40", 44" AMC6EYFP
Double Branch 100 FBV, FBN, FBH, or FBL 3X AFP3FBD 27", 31", 36", 40", 44" AMC6FBFP
Double Branch 100 FCS, FCV, FCN, FCH or FCL 3X AFP3FDD 27", 31", 36", 40", 44" AMC6FDBFP
Double Branch 150 TEB, TED, THED, SEDA 3X AFP3SED 27", 31", 36", 40", 44" AMC6EBFP
SEHA, SELA or SEPA
Double Branch 225 TQD or THQD 3X AFP3QDD 27", 31", 36", 40", 44" AMC6QDFP
Double Branch 225 TFJ or TFK or THFK 3X AFP3TFD 31", 36", 40", 44" AMC6FJFPTF
Double Branch 250 SFHA or SFLA or SFPA 3X AFP3SFD 31", 36", 40" 44" AMC6FJFP1
Double Branch 250 FES, FEV, FEN, FEH or FEL 3X AFP3FED 27", 31", 36", 40", 44" AMC6FEBFP
Double Branch 400 TJD or TJJ 6X AFP6TJD 44" AMC6JKFP
Double Branch 600 TJK or THJK 6X AFP6TJD 44" AMC6JKFP
Double Branch 600 FGL, FGN, FGH or FGP 4X AFP4FGD 40", 44" AMC6FGBFP
Double Branch 600 SGDA or SGHA or SGLA or SGPA 4X AFP4SGD 40", 44" AMC6GBFP2
Double Branch Adjacent to Switch 100 FCS, FCV, FCN, FCH or FCL 4X AFP4FDD 36", 44" AMC6FDSPF
Double Branch Adjacent to Switch 150 SEDA or SEHA or SELA or SEPA 4X AFP4SED 36", 44" AMC6EBSFP
Double Branch Adjacent to Switch 250 SFHA or SFLA or SFPA 4X AFP4SFD 36", 44" AMC6FLSFP
Double Branch Adjacent to Switch 250 FES , FEV, FEN, FEH or FEL 4X AFP4FED 36", 44" AMC6FESFP
Single Branch or Main 225 TFJ or TFK or THFK 3X AFP3TFS 27", 31", 36", 40", 44" AMC3FJFPTF
Single Branch or Main 250 SFHA or SFLA or SFPA 3X AFP3SFS 27", 31", 36", 40", 44" AMC3FJFP1
Single Branch or Main 250 FES, FEV, FEN, FEH or FEL 3X AFP3FES 27", 31", 36", 40", 44" AMC3FEBFP
Single Branch or Main 400 TJD or TJJ 6X AFP6TJS 27", 31", 36", 40", 44" AMC3JKFP
Single Branch or Main 600 TJK or THJK 6X AFP6TJS 27", 31", 36", 40", 44" AMC3JKFP
Single Branch or Main 600 FGV, FGN, FGH or FGP 4X AFP4FGS 27", 31", 36", 40", 44" AMC3FGMFP
Single Branch or Main 600 SGDA or SGHA or SGLA or SGPA 4X AFP4SGS 27", 31", 36", 40", 44" AMC3GMFP
Single Branch or Main 1200 TKM or THKM or SKHA or SKLA 6X AFP6SKS 40", 44" AMC3KMFP
Single Branch or Main 1200 SKPA 6X AFP6SKS 44" AMC3KMFP
Single Branch or Main Adjacent to Switch 250 SFHA or SFLA or SFPA 4X AFP4SFS 36", 44" AMC3FLSFP
Single Branch or Main Adjacent to Switch 250 FES, FEV, FEN, FEH or FEL 4X AFP4FES 36", 44" AMC3FESFP

Circuit Breaker Mounting Modules Plug-In Spectra 2-pole


Mounting Maximum Breaker Breaker X Filler Plate Kit Box Product
Arrangement Amperage Frame Height Product Number Width Range Number
Double Branch 100 THQB or THHQB 3X AFP3QBD 27", 31", 36" 40", 44" AMC6QBFP
Double Branch 100 TEY 3X AFP3EYD 27", 31", 36" 40", 44" AMC6EYFP
Double Branch 100 FCS, FCV, FCN, FCH or FCL 3X AFP3FDD 27", 31", 36", 40", 44" AMC4FDBFP
Double Branch 150 TEB or TED 3X AFP2TED 27", 31", 36" 40", 44" AMC4EBFP
Double Branch 150 SEDA or SEHA or SELA or SEPA, THED 3X AFP3SED 27", 31", 36" 40", 44" AMC4SEFP
Double Branch 225 TQD or THQD 2X AFP2QDD 27", 31", 36" 40", 44" AMC4QDFP
Double Branch 225 TFJ or TFK or THFK 3X AFP3TFD 31", 36", 40", 44" AMC4FJFPTF
Double Branch 250 SFHA or SFLA or SFPA 3X AFP3SFD 31", 36", 40" 44" AMC4FJFP1
Double Branch 250 FES, FEV, FEN, FEH or FEL 3X AFP3FED 27", 31", 36", 40", 44" AMC4FEBFP
Double Branch 400 TJD or TJJ 6X AFP6TJD 44" AMC4JKFP
Double Branch 600 TJK or THJK 6X AFP6TJD 44" AMC4JKFP
Double Branch 600 FGV, FGN, FGH or FGP 4X AFP4FGD 40", 44" AMC4FGBFP
Double Branch 600 SGDA or SGHA or SGLA or SGPA 4X AFP4SGD 40", 44" AMC4GBFP2
Double Branch Adjacent to Switch 100 FCS, FCV, FCN, FCH or FCL 4X AFP4FDD 36", 44" AMC4FDSFP
Double Branch Adjacent to Switch 150 SEDA or SEHA or SELA or SEPA 4X AFP4SED 36", 44" AMC4EBSFP
Double Branch Adjacent to Switch 250 SFHA or SFLA or SFPA 4X AFP4SFD 36", 44" AMC4FLSFP
Double Branch Adjacent to Switch 250 FES, FEV, FEN, FEH or FEL 4X AFP4FED 36", 44" AMC4FESFP
Single Branch or Main 225 TFJ or TFK or THFK 3X AFP3TFS 27", 31", 36", 40", 44" AMC2FJFPTF
Single Branch or Main 250 SFHA or SFLA or SFPA 3X AFP3SFS 27", 31", 36", 40", 44" AMC2FJFP1
Single Branch or Main 250 FES, FEV, FEN, FEH or FEL 3X AFP3FES 27", 31", 36", 40", 44" AMC2FEBFP
Single Branch or Main 400 TJD or TJJ 6X AFP6TJS 27", 31", 36", 40", 44" AMC2JKFP
Single Branch or Main 600 TJK or THJK 6X AFP6TJS 27", 31", 36", 40", 44" AMC2JKFP
Single Branch or Main 600 FGV, FGN, FGH or FGP 4X AFP4FGS 27", 31", 36", 40", 44" AMC2FGMFP
Single Branch or Main 600 SGDA or SGHA or SGLA or SGPA 4X AFP4SGS 27", 31", 36", 40", 44" AMC2GMFP
Single Branch or Main 1200 TKM or THKM or SKHA or SKLA 6X AFP6SKS 40", 44" AMC2KMFP
Single Branch or Main 1200 SKPA 6X AFP6SKS 44" AMC2KMFP
Single Branch or Main Adjacent to Switch 250 SFHA or SFLA or SFPA 4X AFP4SFS 36", 44" AMC2FLSFP
Single Branch or Main Adjacent to Switch 250 FES, FEV, FEN, FEH or FEL 4X AFP4FES 36", 44" AMC2FESFP
1All SE, SF and FE breakers located adjacent to a fusible switch, PCU or TVSS require mounting modules suitable for mounting Adjacent to Switch.
SGDA circuit breaker rated 400 amps maximum.
2THLC 1/2/4 breaker no longer available.
Note: 1X = 1 3/8" vertical panel space.

Rev. 7/13 www.geindustrial.com BuyLog Catalog 11-41


Data subject to change
without notice
Panelboards Section 11
Spectra Series Panelboards
Renewal Parts
Mounting Hardware
Order from the Customer Service Center

Product Features
Module includes fusible switch and panelboard mounting connectors. Fuses not included.
Class R Fuse Clip Kit (for field installation) included with all switches that accept Class R Fuses.
FP suffix indicates that all AFP filler plates are included to fit applicable box widths.

Branch Switch Modules Plug-In Spectra 240 Volts 3-pole


Mounting Fuse Switch X Side Filler Plate Box Width Product
Arrangement Type Amperes Height Kit Part Number Range Number
Double Branch-2 switches H, R, or K 30 4X AFP4X 36", 44" ADS32030HDFP
Double Branch-2 switches H, R, or K 60 4X AFP4X 36", 44" ADS32060HDFP
Double Branch-2 switches H, R, or K 100 5X AFP5X 36", 44" ADS32100HDFP
Double Branch-2 switches T 100 7X AFP7T 36", 44" ADS32100TDFP
Double Branch-2 switches H, R, or K 200 7X AFP7X2 44" ADS32200HDFP
Double Branch-2 switches T 200 7X AFP7T 36", 44" ADS32200TDFP
Double Branch-switch plus space H, R, or K 30 4X AFP4X 36", 44" ADS32030HSFP
Double Branch-switch plus space H, R, or K 60 4X AFP4X 36", 44" ADS32060HSFP
Double Branch-switch plus space H, R, or K 100 5X AFP5X 36", 44" ADS32100HSFP
Single Branch H, R, or K 200 7X AFP7X 36", 44" ADS32200HBFP
Single Branch H, R, or K 400 10X AFP10X 44" ADS32400HBFP
Single Branch T 400 10X AFP10T 36", 44" ADS32400TBFP
Single Branch H, R, or K 600 10X AFP10X 44" ADS32600HBFP
Single Branch T 600 10X AFP10T 36", 44" ADS32600TBFP

Branch Switch Modules Plug-In Spectra 240 Volts 2-pole


Mounting Fuse Switch X Side Filler Plate Box Width Product
Arrangement Type Amperes Height Kit Part Number Range Number
Double Branch-2 switches H, R, or K 30 4X AFP4X 36", 44" ADS22030HDFP
Double Branch-2 switches H, R, or K 60 4X AFP4X 36", 44" ADS22060HDFP
Double Branch-2 switches T 100 7X AFP7T 36", 44" ADS32100TDFP
Double Branch-2 switches H, R, or K 100 5X AFP5X 36", 44" ADS22100HDFP
Double Branch-2 switches H, R, or K 200 7X AFP7X2 44" ADS22200HDFP
Double Branch-2 switches T 200 7X AFP7T 36", 44" ADS22200TD
Double Branch-switch plus space H, R, or K 30 4X AFP4X 36", 44" ADS22030HSFP
Double Branch-switch plus space H, R, or K 60 4X AFP4X 36", 44" ADS22060HSFP
Double Branch-switch plus space H, R, or K 100 5X AFP5X 36", 44" ADS22100HSFP
Single Branch H, R, or K 200 7X AFP7X 36", 44" ADS22200HBFP
Single Branch T 200 7X AFP7X 36", 44" ADS22200TS
Single Branch H, R, or K 400 10X AFP10X 44" ADS22400HBFP
Single Branch T 400 10X AFP10T 36", 44" ADS22400TBFP
Single Branch H, R, or K 600 10X AFP10X 44" ADS22600HBFP
Single Branch T 600 10X AFP10T 36", 44" ADS22600TBFP

Note: 1X = 1 3/8" vertical panel space

Product Number Selection Instructions: See page 11-13

11-42 BuyLog Catalog www.geindustrial.com Rev. 7/13


Data subject to change
without notice
Panelboards Section 11
Spectra Series Panelboards
Renewal Parts
Mounting Hardware
Order from the Customer Service Center

Product Features
Module includes fusible switch and panelboard mounting connectors. Fuses not included.
Class R Fuse Clip Kit (for field installation) included with all switches that accept Class R Fuses.
FP suffix indicates that all AFP filler plates are included to fit applicable box widths.

Branch Switch Modules Plug-In Spectra 600 Volts 3-pole


Mounting Fuse Switch X Side Filler Plate Box Width Product
Arrangement Type Amperes Height Kit Part Number Range Number
Double Branch-2 switches H, R, J, or K 30 4X AFP4X 36", 44" ADS36030HDFP
Double Branch-2 switches H, R, J, or K 60 5X AFP5X 36", 44" ADS36060HDFP
Double Branch-2 switches H, R, J, or K 100 5X AFP5X 36", 44" ADS36100HDFP
Double Branch-2 switches H, R, or K 200 7X AFP7X2 44" ADS36200HDFP
Double Branch-2 switches J 200 7X AFP7T 36", 44" ADS36200JDFP
Double Branch-switch plus space H, R, J, or K 30 4X AFP4X 36", 44" ADS36030HSFP
Double Branch-switch plus space H, R, J, or K 60 5X AFP5X 36", 44" ADS36060HSFP
Double Branch-switch plus space H, R, J, or K 100 5X AFP5X 36", 44" ADS36100HSFP
Single Branch H, R, or K 200 7X AFP7X 36", 44" ADS36200HBFP
Single Branch H, R, or K 400 10X AFP10X 44" ADS36400HBFP
Single Branch J 400 10X AFP10T 36", 44" ADS36400JBFP
Single Branch T 400 10X AFP10T 36", 44" ADS36400TBFP
Single Branch H, R, or K 600 10X AFP10X 44" ADS36600HBFP
Single Branch J 600 10X AFP10T 36", 44" ADS36600JBFP
Single Branch T 600 10X AFP10T 36", 44" ADS36600TBFP
Single Branch L 800 19X AFP19X 44" ADS36800LBFP
Single Branch L 1200 19X AFP19X 44" ADS36120LBFP

Branch Switch Modules Plug-In Spectra 600 Volts 2-pole


Mounting Fuse Switch X Side Filler Plate Box Width Product
Arrangement Type Amperes Height Kit Part Number Range Number
Double Branch-2 switches H, R, J, or K 30 4X AFP4X 36", 44" ADS26030HDFP
Double Branch-2 switches H, R, J, or K 60 5X AFP5X 36", 44" ADS26060HDFP
Double Branch-2 switches H, R, J, or K 100 5X AFP5X 36", 44" ADS26100HDFP
Double Branch-2 switches T 100 7X N/A ADS26100TDFP
Double Branch-2 switches H, R, or K 200 7X AFP7X2 44" ADS26200HDFP
Double Branch-2 switches J 200 7X AFP7T 36", 44" ADS26200JDFP
Double Branch-switch plus space H, R, J, or K 30 4X AFP4X 36", 44" ADS26030HSFP
Double Branch-switch plus space H, R, J, or K 60 5X AFP5X 36", 44" ADS26060HSFP
Double Branch-switch plus space H, R, J, or K 100 5X AFP5X 36", 44" ADS26100HSFP
Single Branch H, R, or K 200 7X AFP7X 36", 44" ADS26200HBFP
Single Branch J 200 7X AFP7X 36" ADS26200JSFP
Single Branch H, R, or K 400 10X AFP10X 44" ADS26400HBFP
Single Branch J 400 10X AFP10T 36", 44" ADS26400JBFP
Single Branch T 400 10X AFP10T 36", 44" ADS26400TBFP
Single Branch H, R, or K 600 10X AFP10X 44" ADS26600HBFP
Single Branch J 600 10X AFP10T 36", 44" ADS26600JBFP
Single Branch T 600 10X AFP10T 36", 44" ADS26600TBFP
Single Branch L 800 19X AFP19X 44" ADS26800LBFP
Single Branch L 1200 19X AFP19X 44" ADS26120LBFP

Note: 1X = 1 3/8" vertical space

Rev. 7/13 www.geindustrial.com BuyLog Catalog 11-43


Data subject to change
without notice
Panelboards Section 11
Spectra Series Panelboards
Renewal Parts
Mounting Hardware
Order from the Customer Service Center

Mounting Hardware With Filler Plate, Straps and Brackets Bolt-On Spectra
Mounting kit with filler plate includes hardware straps, brackets and filler plate.
Filler plate kit includes filler plate and associated hardware only.
Product
Mounting Arrangement Breaker Frame Number of Poles Box Width Range X Height Number
Dual Mounted TEB, TED 2-pole 27"-44" 2X AMCB4EBFP
Dual Mounted TEY 2-pole 27"-44" 3X AMCB4EYFP
Dual Mounted FBV, FBN, FBH, or FBL 2-pole 27"-44" 2X AMCB4FBFP
Dual Mounted FCS, FCV, FCN, FCH or FCL 2-pole 27", 31", 36", 40", 44" 3X AMCB4FDBFP
Dual Mounted FES, FEV, FEN, FEH or FEL 2-pole 27", 31", 36", 40", 44" 3X AMCB4FEBFP
Dual Mounted TQD, THQD 2-pole 27"-44" 2X AMCB4QDFP
Dual Mounted THED, SED, SEH, SEL, SEP 2-pole 27"-44" 3X AMCB4SEFP
Dual Mounted TEB, TED, THED, SED, SEH, SEL, SEP 3-pole 27"-44" 3X AMCB6EBFP
Dual Mounted TEY 3-pole 27"-44" 3X AMCB6EYFP
Dual Mounted FBV, FBN, FBH, or FBL 3-pole 27"-44" 3X AMCB6FBFP
Dual Mounted FCS, FCV, FCN, FCH or FCL 3-pole 27", 31", 36", 40", 44" 3X AMCB6FDBFP
Dual Mounted FES, FEV, FEN, FEH or FEL 3-pole 27", 31", 36", 40", 44" 3X AMCB6FEBFP
Dual Mounted TQD, THQD 3-pole 27"-44" 3X AMCB6QDFP
Dual Mounted SFH, SFL, SFP 2-pole 31"-44" 3X AMCB4FJFP
Dual Mounted SFH, SFL, SFP 3-pole 31"-44" 3X AMCB6FJFP
Dual Mounted TFJ, TFK, THFK 2-pole 36"-44" 2X AMCB4FJFPTF
Dual Mounted TFJ, TFK, THFK 3-pole 36"-44" 3X AMCB6FJFPTF
Dual Mounted FGV, FGN, FGH or FGP 2-pole 40", 44" 4X AMCB4FGBFP
Dual Mounted SGH, SGL, SGP 2-pole 40"-44" 4X AMCB4GBFP
Dual Mounted FGV, FGN, FGH or FGP 3-pole 40", 44" 4X AMCB6FGBFP
Dual Mounted SGH, SGL, SGP 3-pole 40"-44" 4X AMCB6GBFP
Single Mounted SFH, SFL, SFP 2-pole 27"-44" 3X AMCB2FJFP
Single Mounted TFJ, TFK, THFK 2-pole 27"-44" 3X AMCB2FJFPTF
Single Mounted FGV, FGN, FGH or FGP 2-pole 27", 31", 36", 40", 44" 4X AMCB2FGMFP
Single Mounted FES, FEV, FEN, FEH or FEL 2-pole 27", 31", 36", 40", 44" 3X AMCB2FEBFP
Single Mounted SGH, SGL, SGP 2-pole 27"-44" 4X AMCB2GMFP
Single Mounted SFH, SFL, SFP 3-pole 27"-44" 3X AMCB3FJFP
Single Mounted TFJ, TFK, THFK 3-pole 27"-44" 3X AMCB3FJFPTF
Single Mounted FGV, FGN, FGH or FGP 3-pole 27", 31", 36", 40", 44" 4X AMCB3FGMFP
Single Mounted FES, FEV, FEN, FEH or FEL 3-pole 27", 31", 36", 40", 44" 3X AMCB3FEBFP
Single Mounted SGH, SGL, SGP 3-pole 27"-44" 4X AMCB3GMFP
Single Mounted SKP 2-, 3-pole 44" 6X AMCB3KMFP
Single Mounted SKH, SKL, TKM, THKM 2-pole 40"-44" 6X AMCB2KMFP
Single Mounted SKH, SKL, TKM, THKM 3-pole 40"-44" 6X AMCB3KMFP

Filler Plates Bolt-On Spectra


Filler plate kit includes filler plate and associated hardware only.
Product
Mounting Arrangement Breaker Frame Number of Poles Box Width Range X Height Number
Dual Mounted TQD, THQD 2-pole 27"-44" 2X AFP2QDD
Dual Mounted TEB, TED 2-pole 27"-44" 2X AFP2TED
Dual Mounted TEY 2-, 3-pole 27"-44" 3X AFP3EYD
Dual Mounted FBV, FBN, FBH, or FBL 2-pole 27"-44" 2X AFP2FBD
Dual Mounted FBV, FBN, FBH, or FBL 3-pole 27"-44" 3X AFP3FBD
Dual Mounted TQD, THQD 3-pole 27"-44" 3X AFP3QDD
Dual Mounted TEB, TED, THED, 2-, 3-pole 27"-44" 3X AFP3SED
SED, SEH, SEL, SEP
Dual Mounted SFH, SFL, SFP 2-, 3-pole 31"-44" 3X AFP3SFD
Dual Mounted TFJ, TFK, THFK 2-, 3-pole 36"-44" 2X, 3X AFP3TFD
Dual Mounted FGV, FGN, FGH or FGP 3-pole 40", 44" 4X AFP4FGD
Dual Mounted SGH, SGL, SGP 2-, 3-pole 40"-44" 4X AFP4SGD
Single Mounted SFH, SFL, SFP 2-, 3-pole 27"-44" 3X AFP3SFS
Single Mounted TFJ, TFK, THFK 2-, 3-pole 27"-44" 3X AFP3TFS
Single Mounted FGV, FGN, FGH or FGP 2-, 3-pole 27", 31", 36", 40", 44" 4X AFP4FGS
Single Mounted SGH, SGL, SGP 2-, 3-pole 27"-44" 4X AFP4SGS
Single Mounted SKP 2-, 3-pole 44" 6X AFP6SKS
Single Mounted SKH, SKL, TKM, THKM 3-pole 40"-44" 6X AFP6SKS

Notes: 1X = 1 3/8" vertical space. THLC 1/2/4 breaker no longer available.

Product Number Selection Instructions: See page 11-13

11-44 BuyLog Catalog www.geindustrial.com Rev. 7/13


Data subject to change
without notice
Panelboards Section 11
Spectra Series Panelboards
Renewal Parts
Mounting Hardware
Order from the Customer Service Center

Filler Plates Plug-In or Bolt-On Spectra Mounting Hardware Single Breaker Plug-In Spectra
Use to cover unused spaces. Included when ordering AMC module. Only required when mount-
Includes filler plate support brackets and hardware. ing breaker on existing module.
Space Switchboard Product
Kit contains screws and washers to mount one circuit breaker on
X Height1 Box Width Range Section Widths Number AMC circuit breaker mounting module.
1X 27", 31" 35 APP1S Circuit Breaker Mounting Product
2X 27", 31" 35 APP2S Module Part Number Number
3X 27", 31" 35 APP3S
4X 27", 31" 35 APP4S AMC6EB AHKE1
5X 27", 31" 35 APP5S AMC4SE
6X 27", 31" 35 APP6S AMC4EB
1X 36", 40" 40 APP1 AMC6EBS
2X 36", 40" 40 APP2 AMC6EL AHKEL1
3X 36", 40" 40 APP3 AMC2FLS AHKF1
4X 36", 40" 40 APP4 AMC6FJ
5X 36", 40" 40 APP5 AMC4FJ
6X 36", 40" 40 APP6 AMC3FJ
1X 44" 45 APP1W AMC2FJ
2X 44" 45 APP2W AMC6FLS
3X 44" 45 APP3W AMC3FLS
4X 44" 45 APP4W AMC4FLS
5X 44" 45 APP5W AMC2GM AHKG1
6X 044" 45 APP6W AMC6GB
AMC4GB
1 X-height: 1X = 1 3/8"
AMC3GM
AMC2JK AHKJ1
AMC6JK
AMC4JK
Mounting Hardware Plug-In or Bolt-On Spectra ADS Switch AMC3JK
Replacement Load Base Kits AMC3LB AHKLB1
AMC6LB
Includes load base, clips and lugs. AMC4QD AHKQ1
Replacement AMC6QD
for Load Base Load Base Load Base - Load Base Product FCS, FCV, FCN, FCH or FCL AHKFD1
Part Number Ampere Rating No. of Poles Voltage Number FGV, FGN, FGH or FGP AHKFG1

ADS22030HD 331A1519G1
ADS32030HD 331A1519G2
ADS322060HD 331A1519G3 Mounting HardwareHardware only; no brackets
ADS32060HD 331A1519G4
ADS26030HD 331A1519G5 or straps Bolt-On Spectra
ADS36030HD 331A1519G6
Product
ADS26060HD 331A1519G7 Breaker Frame Number
ADS36060HD 331A1519G8
ADS36200JD 331A1519G12 SE AHKBE1
ADS26200JD 331A1519G16 SF AHKBF1
ADS36200JM 331A1519G20 SG AHKBG1
ADS26200JM 331A1519G22 THQD AHKBQ1
100A 2-pole 240V & 600V 331A1519G9 FCS, FCV, FCN, FCH or FCL AHKBFD1
100A 3-pole 240V & 600V 331A1519G10 FGV, FGN, FGH or FGP AHKBFG1
100A 3-pole 240V & 600V 331A1519G14 FB AHKBFB1
100A 2-pole 240V & 600V 331A1519G18
200A 3-pole 240V & 600V 331A1519G11
200A 2-pole 240V & 600V 331A1519G13
200A 2-pole 240V & 600V 331A1519G15
200A 2-pole 240V & 600V 331A1519G17
200A 3-pole 240V & 600V 331A1519G19
200A 2-pole 240V & 600V 331A1519G21
400A 2-pole 240V & 600V 331A1545G1
400A 3-pole 240V & 600V 331A1545G3
400A 2-pole 240V & 600V 331A1545G5
400A 3-pole 240V & 600V 331A1545G7
600A 2-pole 240V & 600V 331A1545G2
600A 3-pole 240V & 600V 331A1545G4
600A 2-pole 240V & 600V 331A1545G6
600A 3-pole 240V & 600V 331A1545G8
400-1200A 331A1543G1

Rev. 7/13 www.geindustrial.com BuyLog Catalog 11-45


Data subject to change
without notice
Panelboards Section 11
Spectra Series Panelboards
Renewal Parts
Main Lug Modules; Neutral and Ground Kits
Plug-In or Bolt-On

Lug Kits and Modules Plug-In Spectra


FP suffix indicates all AFPML cover plates included to fit applicable box widths.
Can be converted to dual main lug version by adding lug kits (see Accessories).
Mechanical lug modules can be converted to compression lug modules by replacing standard lugs with AMKP compression lug kit
(see Accessories)
Can be used for feed-thru lugs application by replacing standard cover plate with AFL feed-thru lug cover plate kit (see Accessories).
Lug Ampere Lug X Lugs Wires Wire Range Included Box Width Product
Rating Type Height Per Phase per Lug (Cu/Al) Cover Plate Range Number
250 Mechanical 4X 1 1 #6-350kcmil AFPML4X 27",36" AML3250SFP1
250 Mechanical 6X 1 1 #6-350kcmil AFPML6X 36" AML3250FP
400 Mechanical 4X 1 2 #2-500kcmil AFPML4X 27",36",44" AML3400SFP1
400 Mechanical 6X 1 2 #2-500kcmil AFPML6X 36",44" AML3400FP
600 Mechanical 4X 1 2 #2-500kcmil AFPML4X 27",36",44" AML3600SFP1
600 Mechanical 6X 1 2 #2-500kcmil AFPML6X 36",44" AML3600FP
800 Mechanical 6X 2 2 #2-500kcmil AFPML6XW 36",44" AML3800FP
1200 Mechanical 6X 2 2 #2-500kcmil AFPML6XW 36",44" AML3120FP
250 Compression 6X 2 1 350kcmil AFPML6X 36" AML3250CFP
400 Compression 6X 2 1 500kcmil AFPML6X 36",44" AML3400CFP
600 Compression 6X 2 1 500kcmil AFPML6X 36",44" AML3600CFP
800 Compression 6X 4 1 500kcmil AFPML6XW 36",44" AML3800CFP
1200 Compression 6X 4 1 500ckmil AFPML6XW 36",44" AML3120CFP
14X modules cannot be converted to compression lug version.

Lug Kits and Modules Plug-In or Bolt-On SpectraNeutral


Includes mechanical lugs and bonding strap.
250 to 600A neutral kits can be converted to dual main version by doubling the main lug quantity using lug kits (see Accessories).
Main lug on neutral kit can be converted to compression main using AMKP lug kit.
Product
Lug Amp Rating No. of Main Lugs No. of Wires Wire Range (Cu/Al) Number
Bolt-On
250/400 Single/Dual 2 (MAIN) #2 - 600kcmil ANKN400
16 #14 - 2/0
5 #6 - 300kcmil
24 #14 - #4
600/800/1200 Single/Dual 8 (MAIN) #2 - 600kcmil ANKN120
9 #14 - 2/0
10 #6 - 300kcmil
10 #14 - #4
Plug-In
800 Dual 8 (MAIN) #2 - 500kcmil ANK800D
8 #14 - 2/0
10 #6 - 300kcmil
4 #2 - 500kcmil
1200 Dual 8 (MAIN) #2 - 500kcmil ANK120D
8 #14 - 2/0
10 #6 - 300kcmil
4 #2 - 500kcmil

For 3ph, 4W single-section panelboards, use a standard neutral.


For 3ph, 4W multi-section panelboards, use a standard neutral on the last section, and a dual main neutral on the first and middle sections.

Lug Kits and Modules Plug-In or Bolt-On SpectraGround


AEG10 and AEG21 should be ordered in multiples of 10 due to 10 kits per carton bulk-packaging.
AEG21S and AEG31S are packaged as quantity 1 kit per carton.
Product
Bonding Type Total Circuits No. of Wires Wire Range (Cu/Al) Number
Bonded 10 10 #6-2/0 Cu/AI AEG10
Bonded 21 9 Solid: #14-#8 Cu or #12-#8 AI AEG21
or Stranded: #12-#8 Cu or #12-#8 AI
or Stranded: #10-#4 Cu or #10-#4 AI
Insulated/Isolated 21 9 Solid: #14-#8 Cu or #12-#8 AI AEG21S
or Stranded: #12-#8 Cu or #12-#8 AI
or Stranded: #10-#4 Cu or #10-#4 AI
Insulated/Isolated 31 10 #6-2/0 Cu/AI AEG31S

Product Number Selection Instructions: See page 11-13

11-46 BuyLog Catalog www.geindustrial.com Rev. 7/13


Data subject to change
without notice
Panelboards Section 11
Spectra Series Panelboards
Merchandise
Renewal Parts
Accessories

Feed Thru Lug Cover Plate Kits


Use to convert AML main lug module to feed thru lug module
Note: This lug furnished with
Kit includes barrier and oversized cover plates. 6 pack kits only. (For dual
main lug conversion)
(Discard original cover plates.)
Note: This lug furnished with
Product all kits.
Lug Amp Rating X Height Box Width Range Number
250/400/600 9X 27", 36", 44" AFL600
800/1200 12X 36", 44" AFL120
Crimp Lugs

Mechanical Lug Kits and Modules


Use to convert AML main mechanical lug modules or ANK
neutral modules to dual main lug version. Compression Lug Kits and Modules
Can be used to replace standard lugs with oversized lugs. Use to convert AML main mechanical lug modules to compression
Lugs Product
lug version.
Wire Range (Cu/Al) Per Kit Wires per Lug Number Crimp Tool Crimp Tool Crimp Tool
#6-350kcmil 3 1 AMK350 Wire Package Die Cat. Die Cat. Die Cat. Product
Size Type No. Homac No. Burndy No. T&B Number
#2-500kcmil 3 2 AMK500
#2-600kcmil 3 2 AMK600 1/0 3 PACK 15CA52 296 50 AMKP101
3/0-750kcmil 3 2 AMK750 1/0 6 PACK 15CA52 296 50 AMKP2101
2/0 3 PACK 15CA52 297 54H AMKP202
2/0 6 PACK 15CA52 297 54H AMKP2202
3/0 3 PACK 15CA66 467 60 AMKP303
Compression Lug Kits 3/0 6 PACK 15CA66 467 60 AMKP2303
4/0 3 PACK 15CA71H 298 66 AMKP404
Use to replace standard load-side mechanical lugs on ADS
4/0 6 PACK 15CA71H 298 66 AMKP2404
branch switches. 250kcmil 3 PACK 15CA76 324 71H AMKP250
Each kit includes 3 lugs. 250kcmil 6 PACK 15CA76 324 71H AMKP2250
300kcmil 3 PACK 15CA87H 15C87 470 76 AMKP300
Product 300kcmil 6 PACK 15CA87H 15C87 470 76 AMKP2300
Wire Range Lugs Per Phase For Switch Amperes Number 350kcmil 3 PACK 15CA96H 15C96H 299 87H AMKP350
350kcmil 6 PACK 15CA96H 15C96H 299 87H AMKP2350
#8-1/0 Cu/AI 1 30, 60, or 100 KLP101
400kcmil 3 PACK 15CA96H 15C96H 472 94H AMKP400
#4-300kcmil Cu/Al 1 200 KLP300
400kcmil 6 PACK 15CA96H 15C96H 472 94H AMKP2400
2/0-500kcmil Cu/Al 2, 4 800 or 1200 KLP500
500kcmil 3 PACK 15CA106A 15C106R 300 99H AMKP500
400-500kcmil Cu or 2, 4 800 or 1200 KLP600
500kcmil 6 PACK 15CA106A 15C106R 300 99H AMKP2500
400-600kcmil Al
600kcmil 3 PACK 15CA115H 15C115H 473 106H AMKP600
500-750kcmil Cu/Al 2, 4 800 or 1200 KLP750
600kcmil 6 PACK 15CA115H 15C115H 473 106H AMKP2600
700/750 3 PACK 15C125H 936 115H AMKP750
kcmil
700/750 6 PACK 15C125H 936 115H AMKP2750
kcmil

Notes: For dual main applications, double the kit quantity.

Permanent Circuit Number Tabs


For Circuit Numbers Product Number
1-49 APN49
1-99 APN99

Rev. 7/13 www.geindustrial.com BuyLog Catalog 11-47


Data subject to change
without notice
Panelboards Section 11
Spectra Series Panelboards
Merchandise
Renewal Parts
Interiors, Boxes and Fronts
Order from Customer Service Center

Product Features Interior Aluminum


In selecting an interior X-height, add up all required main and Panel Current Product
Rating (amperes) Space X Height Number
branch module X-heights, plus any required spaces for future.
250 18 APN1802U
UL Service Entrance label is included on all interiors. 250 28 APN2802U
250 38 APN3802U
250 53 APN5302U
400 18 APN1804U
Boxes 400 28 APN2804U
Panel Current Space X Box Box Product 400 38 APN3804U
Rating (amperes) Height Width/Depth Height (inches) Number 400 48 APN4804U
250, 400 18 27" W x 14.5" D 64.63 APB2765A 600 23 APN2306U
250 28 27" W x 14.5" D 64.63 APB2765C 600 38 APN3806U
250, 400, 600 38 27" W x 14.5" D 89.25 APB2789 600 48 APN4806U
400 28 27" W x 14.5" D 75.5 APB2775 800 23 APN2308U
600 23 27" W x 14.5" D 64.63 APB2765B 800 38 APN3808U
250, 400, 600 18, 28 36" W x 11.5" D 64.63 APB3665 800 43 APN4308U
400, 800, 1200 28 36" W x 11.5" D 75.5 APB3675 1200 28 APN2812U
250, 400, 600, 38 36" W x 11.5" D 89.25 APB3689 1200 38 APN3812U
800, 1200 1200 43 APN4312U
250, 400, 600, 43,48 36" W x 11.5" D 96.13 APB3696
800, 1200 53
400, 600 18, 23 44" W x 11.5" D 64.63 APB4465
400, 800, 1200 23, 28 44" W x 11.5" D 75.5 APB4475
Interior Copper
400, 600, 800, 38 44" W x 11.5" D 89.25 APB4489 Panel Current Product
1200 Rating (amperes) Space X Height Number
400, 600, 800, 43, 48 44" W x 11.5" D 96.13 APB4496 250 18 APN1802UB4
1200 250 28 APN2802UB4
250 38 APN3802UB4
250 53 APN5302UB4
400 18 APN1804UB4
Front w/Door 400 28 APN2804UB4
Panel Current Space X Box Box Product 400 38 APN3804UB4
Rating (amperes) Height Width/Depth Height (inches) Number 400 48 APN4804UB4
250 18 27" W x 14.5" D 64.63 APF6518NS 600 23 APN2306UB4
250 28 27" W x 14.5" D 64.63 APF6528NS 600 38 APN3806UB4
250 38 27" W x 14.5" D 89.25 APF8938NS 600 48 APN4806UB4
400 18 27" W x 14.5" D 64.63 APF6518S 800 23 APN2308UB4
400 28 27" W x 14.5" D 75.5 APF7528S 800 38 APN3808UB4
600 23 27" W x 14.5" D 64.63 APF6523S 800 43 APN4308UB4
600 38 27" W x 14.5" D 89.25 APF8938S 1200 28 APN2812UB4
1200 38 APN3812UB4
1200 43 APN4312UB4

4-pc Fronts
Panel Current Space X Box Box Product
Rating (amperes) Height Width/Depth Height (inches) Number
250 18 36" W x 11.5" D 64.63 APF6518N
250 28 36" W x 11.5" D 64.63 APF6528N
250 38 36" W x 11.5" D 89.25 APF8938N
250 53 36" W x 11.5" D 96.13 APF9653N
400 18 36" W x 11.5" D 64.63 APF6518
400, 800, 1200 28 36" W x 11.5" D 75.5 APF7528
400, 600, 800, 1200 38 36" W x 11.5" D 89.25 APF8938
600 23 36" W x 11.5" D 64.63 APF6523
400, 600, 800, 1200 48 36" W x 11.5" D 96.13 APF9648
800 23 36" W x 11.5" D 75.5 APF7523
800, 1200 43 36" W x 11.5" D 96.13 APF9643
400 18 44" W x 11.5" D 64.63 APF6518W
600 23 44" W x 11.5" D 64.63 APF6523W
800 23 44" W x 11.5" D 75.5 APF7523W
400, 1200 28 44" W x 11.5" D 75.5 APF7528W
400, 600, 800, 1200 38 44" W x 11.5" D 89.25 APF8938W
800, 1200 43 44" W x 11.5" D 96.13 APF9643W
400, 600 48 44" W x 11.5" D 96.13 APF9648W

Product Number Selection Instructions: See page 11-13

11-48 BuyLog Catalog www.geindustrial.com Rev. 7/13


Data subject to change
without notice
Panelboards Section 11
Spectra Series Panelboards
Type SCP Plus
Renewal Parts
Enclosure Options, Mounting Hardware and Spare Parts
Order through the Customer Service Center unless stated otherwise below.

Boxes Mounting HardwareHardware Kit and Straps


Product Maximum Breaker
Box Width/Depth X Height Box Height (inches) Number Mounting Breaker Breaker Number Product
Arrangement Frame Amperage of Poles Number
31"W x 11.5"D 15 49.375 ACB311149
31"W x 11.5"D 18 53.5 ACB311153 Dual Mounted SHE, SEL, 150A ACTMKSE
31"W x 11.5"D 21 57.625 ACB311157 SED, SEP
31"W x 11.5"D 24 61.75 ACB311161 Dual Mounted TEB, TED, THED 150A single-pole ACTMKEB1P
31"W x 11.5"D 27 65.875 ACB311165 Dual Mounted TEB, TED, THED 150A two-pole ACTMKEB2P
31"W x 11.5"D 30 70 ACB311170 Dual Mounted TEB, TED, THED 150A three-pole ACTMKEB3P
31"W x 11.5"D 33 74.125 ACB311174 Dual Mounted TFK, SFH, 250A ACTMKSF
31"W x 11.5"D 36 78.25 ACB311178 SFL, SFP
31"W x 11.5"D 39 82.275 ACB311182 Dual Mounted TQD, THQD 225A two-pole ACTMKQD2P
31"W x 11.5"D 42 86.5 ACB311186 Dual Mounted TQD, THQD 225A three-pole ACTMKQD3P
40"W x 11.5"D 15 49.375 ACB401149 Dual Mounted TJD, TJJ, TJK 400A ACTMKJD
40"W x 11.5"D 18 53.5 ACB401153 Dual Mounted SGD, SGH, 400A, 600A ACTMKSG
40"W x 11.5"D 21 57.625 ACB401157 SGL, SGP
40"W x 11.5"D 24 61.75 ACB401161 Single Mounted SGD, SGH, 400A, 800A ACSMKSG
40"W x 11.5"D 27 65.875 ACB401165 SGL, SGP
40"W x 11.5"D 30 70 ACB401170 Single Mounted SKH, SKL 800A, 1200A ACSMKSK
40"W x 11.5"D 33 74.125 ACB401174 Single Mounted TB4 400A ACSMKTB4
40"W x 11.5"D 36 78.25 ACB401178 Single Mounted TB6 600A ACSMKTB6
40"W x 11.5"D 39 82.275 ACB401182 Single Mounted TB8 800A ACSMKTB8
40"W x 11.5"D 42 86.5 ACB401186

Box dimensions are inside dimensions. Add 1/4-inch for outside dimensions.
Boxes furnished with no knockouts. Mounting HardwareFiller Plate and Filler Hardware
Maximum Breaker
Mounting Breaker Breaker Number Product
Arrangement Frame Amperage of Poles Number
Fronts
Dual Mounted SHE, SEL, 150A ACTFPKSE
Product
SED, SEP
Box Width/Depth X Height Box Height (inches) Number
Dual Mounted TEB, TED, THED 150A single-pole ACTFPKEB1P
31"W x 11.5"D 15 49.375 ACF3149S Dual Mounted TEB, TED, THED 150A two-pole ACTFPKEB2P
31"W x 11.5"D 18 53.5 ACF3153S Dual Mounted TEB, TED, THED 150A three-pole ACTFPKEB3P
31"W x 11.5"D 21 57.625 ACF3157S Dual Mounted TFK, SFH, 250A ACTFPKSF
31"W x 11.5"D 24 61.75 ACF3161S SFL, SFP
31"W x 11.5"D 27 65.875 ACF3165S Dual Mounted TQD, THQD 225A two-pole ACTFPKQD2P
31"W x 11.5"D 30 70 ACF3170S Dual Mounted TQD, THQD 225A three-pole ACTFPKQD3P
31"W x 11.5"D 33 74.125 ACF3174S Dual Mounted TJD, TJJ, TJK 400A ACTFPKJD
31"W x 11.5"D 36 78.25 ACF3178S Dual Mounted SGD, SGH, 400A, 600A ACTFPKSG
31"W x 11.5"D 39 82.275 ACF3182S SGL, SGP
31"W x 11.5"D 42 86.5 ACF3186S Single Mounted SGD, SGH, 400A, 800A ACSFPKSG
40"W x 11.5"D 15 49.375 ACF4049S SGL, SGP
40"W x 11.5"D 18 53.5 ACF4053S Single Mounted SKH, SKL 800A, 1200A ACSFPKSK
40"W x 11.5"D 21 57.625 ACF4057S Single Mounted TB4 400A ACSFPKTB4
40"W x 11.5"D 24 61.75 ACF4061S
40"W x 11.5"D 27 65.875 ACF4065S
40"W x 11.5"D 30 70 ACF4070S
40"W x 11.5"D 33 74.125 ACF4074S Mounting HardwareHardware to Mount One Breaker
40"W x 11.5"D 36 78.25 ACF4078S Maximum Breaker
40"W x 11.5"D 39 82.275 ACF4082S Mounting Breaker Breaker Number Product
40"W x 11.5"D 42 86.5 ACF4086S Arrangement Frame Amperage of Poles Number

Flush fronts (F) are 2 inches larger than box. Surface fronts (S) are 1/4-inch larger Dual Mounted SHE, SEL, 150A ACTHKSE
than box. SED, SEP
Dual Mounted TEB, TED, THED 150A single-pole ACTHKEB1P
Dual Mounted TEB, TED, THED 150A two-pole ACTHKEB2P
Dual Mounted TEB, TED, THED 150A three-pole ACTHKEB3P
Dual Mounted TFK, SFH, 250A ACTHKSF
SFL, SFP
Dual Mounted TQD, THQD 225A two-pole ACTHKQD2P
Dual Mounted TQD, THQD 225A three-pole ACTHKQD3P
Dual Mounted TJD, TJJ, TJK 400A ACTHKJD
Dual Mounted SGD, SGH, 400A, 600A ACTHKSG
SGL, SGP
Single Mounted SGD, SGH, 400A, 800A ACSHKSG
SGL, SGP
Single Mounted SKH, SKL 800A, 1200A ACSHKSK
Single Mounted TB4 400A ACSHKTB4
Note: If filler plates for SCP+ panels are required, please contact
Houston equipment plant.
Note: THLC 1/2/4 breaker no longer available.

Rev. 7/13 www.geindustrial.com BuyLog Catalog 11-49


Data subject to change
without notice
Panelboards Section 11
Spectra Series Panelboards
Power
Renewal Parts
Type CCB and QMR Panelboards
Order through the Customer Service Center unless stated otherwise below.

Mounting HardwareCopper Straps for Use on Cu or Al Device and Hardware Suffix Selection
Main Bus Dual Mounted Device Type

Product Panelboard Twin (Double) TQD, TED,


Breaker Frame Kit Ampere Rating Number Lighting Type Mount Single Mount Panel Subfeed

TEB/TED 150A TED1DPK CCB/QMR DPK SPK


TFJ/TFK/TFL 225A TF2DPK Switchboards DPK SPK
TQD 225A TQ2DPK To ensure a unit shipment, you must order using the device
TJD/TJJ/TJK 400A TJ4DPK
TJK 600A TJ6DPK
product number plus suffix; orders for the device and kit as
TLB1/THLC1 150A THLC1DPK separate items will ship as separate items.
TEL 150A TEL1DPK
TB1 150A TB1DPK
SFH/SFL 225A SF2DPK1,2
1If mounting hardware exists must order SFCARE for additional insulators.
2225A Maximum

Mounting HardwareCopper Straps for Use on Cu or Al


Main Bus Single Mounted
Product
Breaker Frame Kit Ampere Rating Number
TKM8/THKM8 800A TK8SPK3
TB1 100A TB1SPK3
TB6 600A TB6SPK3
TB8 800A TB8SPK3
TKM12/THKM12 1200A TK12SPK3,4
SKH8 800A SK8SPK3
SKH12 1200A SK12SPK3
3Deep mounted interior is required.
4Requires 7x of space if mounted at extreme end (top or bottom) of interior or 8x if
mounted in center of interior.

Product Number Selection Instructions: See page 11-13

11-50 BuyLog Catalog www.geindustrial.com Rev. 7/13


Data subject to change
without notice
Panelboards Section 11
Spectra Series Panelboards
Power
Renewal Parts
Type CCB and QMR Panelboards
Order through the Customer Service Center unless stated otherwise below.

Replacement Panelboard CCB Front (Flush or Surface) Replacement Panelboard CCB Box
Box Height Product Product
Box Width/Depth X Height (inches) Number1 Box Width/Depth X Height Box Height (inches) Number
31" Wide x 9 1/2" 15X 49 CBA3121S,F 31" Wide x 9 1/2" 15X 49 DASW3121
Deep Box (No Knockouts) Deep Box (No Knockouts)
31" Wide x 9 1/2" 18X 53 1/2 CBA3124S,F 31" Wide x 9 1/2" 21X 57 5/8 DASW3127
Deep Box (No Knockouts) Deep Box (No Knockouts)
31" Wide x 9 1/2" 21X 57 5/8 CBA3127S,F 31" Wide x 9 1/2" 24X 61 3/4 DASW3130
Deep Box (No Knockouts) Deep Box (No Knockouts)
31" Wide x 9 1/2" 24X 61 3/4 CBA3130S,F 31" Wide x 9 1/2" 27X 65 7/8 DASW3133
Deep Box (No Knockouts) Deep Box (No Knockouts)
31" Wide x 9 1/2" 30X 70 CBA3136S,F 31" Wide x 9 1/2" 30X 70 DASW3136
Deep Box (No Knockouts) Deep Box (No Knockouts)
31" Wide x 9 1/2" 42X 86 1/2 CBA3148S,F 31" Wide x 9 1/2" 36X 78 1/4 DASW3142
Deep Box (No Knockouts) Deep Box (No Knockouts)
35" Wide x 11 1/2" 36X 78 1/4 CBA3542S,F 35" Wide x 11 1/2" 33X 74 1/8 DACB3539
Deep Box (No Knockouts) Deep Box (No Knockouts)
40" Wide x 11 1/2" 21X 57 5/8 CBA4027S,F 35" Wide x 11 1/2" 39X 82 3/8 DACB3545
Deep Box (No Knockouts) Deep Box (No Knockouts)
40" Wide x 11 1/2" 24X 61 3/4 CBA4030S,F 40" Wide x 11 1/2" 21X 57 5/8 DACB4027
Deep Box (No Knockouts) Deep Box (No Knockouts)
40" Wide x 11 1/2" 30X 70 CBA4036S,F 40" Wide x 11 1/2" 24X 61 3/4 DACB4030
Deep Box (No Knockouts) Deep Box (No Knockouts)
40" Wide x 11 1/2" 33X 74 1/8 CBA4039S,F 40" Wide x 11 1/2" 27X 65 7/8 DACB4033
Deep Box (No Knockouts) Deep Box (No Knockouts)
40" Wide x 11 1/2" 36X 78 1/4 CBA4042S,F 40" Wide x 11 1/2" 30X 70 DACB4036
Deep Box (No Knockouts) Deep Box (No Knockouts)
40" Wide x 11 1/2" 39X 82 3/8 CBA4045S,F 40" Wide x 11 1/2" 33X 74 1/8 DACB4039
Deep Box (No Knockouts) Deep Box (No Knockouts)
1Flush fronts (F) are 2 inches larger than box. Surface fronts (S) are 1/4-inch larger 40" Wide x 11 1/2" 36X 78 1/4 DACB4042
than box. Deep Box (No Knockouts)
40" Wide x 11 1/2" 39X 82 3/8 DACB4045
Deep Box (No Knockouts)
40" Wide x 11 1/2" 42X 86 1/2 DACB4048
Deep Box (No Knockouts)
Note: Box dimensions are inside dimensions. Add 1/4-inch for outside dimensions.
Boxes furnished without knockouts as standard.

Filler Plates
Product
Panel Type X Height Number
QMR 1X QMRFP1
QMR 2X QMRFP2
QMR 5X QMRFP5
QMR 3X 75C145005G703
CCB 1X CCBFP1
CCB 3X CCBFP3
CCB 5X CCBFP5
CCB 2X 75C145005G711
CCB 6X 75C145005G715
SCP+ 1X SCPFP1
SCP+ 2X SCPFP2
SCP+ 3X SCPFP3
SCP+ 5X SCPFP5

(Order from Local Sales Office or Equipment Plant)

Rev. 7/13 www.geindustrial.com BuyLog Catalog 11-51


Data subject to change
without notice
Panelboards Section 11
Spectra Series Panelboards
Power
Renewal Parts
Type CCB and QMR Panelboards
Order through the Customer Service Center unless stated otherwise below.

QMR Fusible Switch 240V1, 2 QMR Fusible Switch 600V1, 2


Switch Number Product Switch Number Product
Amps of Poles Description Number Amps of Poles Description Number
30 3 Left Hand Unit THFP321L 30 3 Right Hand Unit THFP361
30 3 Right Hand Unit - 3X THFP321X 30 3 Left Hand Unit THFP361L
60 3 Right Hand Unit THFP322 60 3 Right Hand Unit THFP362
60 3 Left Hand Unit THFP322L 60 3 Left Hand Unit THFP362L
60 3 Right Hand Unit - 3X THFP322X 100 3 Right Hand Unit THFP363
60 3 Left Hand Unit - 3X THFP322XL 100 3 Left Hand Unit THFP363L
100 3 Right Hand Unit THFP323 200 3 Center Mount THFP364
100 3 Left Hand Unit THFP323L 400 3 Center Mount THFP365
200 3 Center Mount THFP324 600 3 Center Mount THFP366
400 3 Center Mount THFP325 800 3 Center Mount THFP367
600 3 Center Mount THFP326 1200 3 Center Mount THFP368
1Limited availability. Obsolete when inventory depleted.
2Switch and mounting hardware kit must be ordered separately

QMR Mounting Hardware Kits Are Copper for Use with Maximum Horsepower Ratings QMR Fusible Switch
Cu or Al Main Bus Dual Mounted Vac Vdc

Product Rating in 2-Pole 3-Pole 2-Pole 3-Pole


Breaker Frame Kit Ampere Rating Voltage Number Amperes3 120 240 480 600 240 480 600 125 250
THFP 30-60A 240 & 600V THFP62DPK With Standard and Fuses (Class H)
THFP 100A 600V THFP63DPKJ 30 1/2 1 1/2 3 3 3 5 7 1/2 2 5
THFP 100A 240 & 600V THFP63DPK 60 1 1/2 3 5 10 7 1/2 15 15 5 10
THFP 100-30/60 600V THFP63DPKC 100 7 1/2 10 15 15 25 30 20
Note: QMR Power Panelboards 600V, 100A double branch units require a minimum 200 15 25 30 25 50 60 40
400 50 100 125
width of 40". 600V, 30A and 60A double branch, and 240V, 30A, 60A and 100A
600 75 150 200
single and double branch units can be built in a 35" wide enclosure.
With Time-delay Fuses (Class H)
30 2 5 10 15 10 20 20 3
60 3 10 20 25 20 40 50 5
QMR Mounting Hardware Kits Are Copper for Use with 100 15 30 40 30 60 75
200 30 50 50 60 125 150
Cu or Al Main Bus Single Mounted 400 125 250 350
Product 600 200 400 500
Breaker Frame Kit Ampere Rating Voltage Number 3Ratings are based on latest revision of the National Electric Code Article 430.
THFP 30/60A 240V THFP22SPK Horsepower ratings for switches with standard class H fuses are based on
THFP 30/60/100A 240V & 600V THFP62SPK one-time fuses having minimum time-delay.
THFP 100A 600V THFP63SPK
When time-delay fuses are used the horsepower ratings are maximum for the
THFP 200A 240 & 600V THFP64SPK
THFP 400A 240 & 600V THFP65SPK
switches.
THFP 600A 240 & 600V THFP66SPK
THFP 1200A 240 & 600V THFP67SPK
QMR Fusible Switch Terminations4
Note: QMR Power Panelboards 600V, 100A double branch units require a minimum Switch Wire Range Wires Lugs
width of 40". 600V, 30A and 60A double branch, and 240V, 30A, 60A and 100A Amperes Voltage (Cu/Al) per Lug per Phase
single and double branch units can be built in a 35" wide enclosure. 30 250/600 #14-10 1 1
60 250/600 #14-2 1 1
100 250/600 #10-1/0 1 1
200 250/600 #6-250kcmil or 1 1
2(I/O-250kcmil)
400 250/600 #6-250kcmil or 1 1
2(I/O-250kcmil)
600 250/600 250-350kcmil Cu or 2 2
350-500kcmil Al
800 250/600 #4-600kcmil 1 4
1000 250/600 #4-600kcmil 1 4
4For optional lugs refer to GEH-460B

11-52 BuyLog Catalog www.geindustrial.com Rev. 7/13


Data subject to change
without notice
Panelboards Section 11
Spectra Series Panelboards

Available Publications

Spectra Series Power Panels Plug-In and Bolt-On Spectra Series Plug-In (Only) (continued)
Circuit Breaker Mounting Instructions (Modules) Installing Fusible Switches
TKM, THKM, TK4V, LA, SKPA GEH-5623 Fuse Pullers DEH-034
TJK, TJD, TJJ, THJK, TJ4V, THJ4V, TJL4V GEH-5624 Class R Fuse Rejector Kit GEH-4616
TEB, TED, THED, TEL, SEDA, SEHA, SELA, SEPA GEH-5625 R Fuse Rejection Pin, 400-600 Ampere Switch Units GEH-5577
TFJ, TFK, THFK, TFL, SFHA, SFLA, SEPA GEH-5626 Lug Kits into GE Type ADS Switches GEH-5944
TQD, THQD GEH-5643 Alternate Lugs, 30-1200 Ampere Fusible Switch Units GEJ-3050
THLC1 GEH-5644 Installing Fusible Switch Expansion Kits
SGDA, SGHA, SGLA, SGPA (3 pole) GEH-5673 30/60 Ampere Expansion Kit GEH-5547
SGDA, SGHA, SGLA, SGPA (2 pole) GEH-5674 60A, 100A Expansion Kits for Type ADS Fusible Switch Units GEH-5581
THLC2, THLC4, TLB4 (3 pole) GEH-5675 200 Ampere Expansion Kit (J, T Fuses) GEH-5582
THLC2, THLC4, TLB4 (2 pole) GEH-5676 200 Ampere Expansion Kit (H, K, R Fuses) GEH-5889
TEY, THQB, THHQB GEH-5677 Handle and Load Base Replacements on Fusible Switches
Circuit Breaker Mounting Hardware Kits Handle Replacement: 400-1200 Ampere Switches GEH-5553
TQD, THQD, SE TEB, TED, THED, THLC1, SF, TFJ, TFK, THFK, SG, Load Base Replacement for Type ADS 400-600 Ampere Switches GEH-5576
TJK, THJK, TJD, TJJ, THLC2, THLC4 GEH-5913
Miscellaneous
Installing Lugs Typical - Fusible Mains and Feeders DE-166
Type AML Main Lug Kits GEH-5588
Technical Data, Spectra Series Panelboards - Pressure Locked
Type AML Feed Thru Main Lug Kits GEH-5630 Connectors DE-168
Installing Fusible Switches
Fuse Pullers DEH-034
Class R Fuse Rejector Kit GEH-4616 Spectra Series Bolt-On (Only)
R Fuse Rejection Pin, 400-600 Ampere Switch Units GEH-5577 Circuit Breaker Mounting Instructions (Straps)

Lug Kits into GE Type ADS Switches GEH-5944 TEB, TED, THED, SED, SEH, SEL, SEP DEH-047

Alternate Lugs, 30-1200 Ampere Fusible Switch Units GEJ-3050 SGH, SFL, SFP DEH-059

Installing Fusible Switch Expansion Kits SGH, SGL, SGP DEH-060

30/60 Ampere Expansion Kit GEH-5547 SKH, SKL, SKP, TKM, THKM DEH-061

60A, 100A Expansion Kits for Type ADS Fusible Switch Units GEH-5581 TEY DEH-062

200 Ampere Expansion Kit (J, T Fuses) GEH-5582 TQD, THQD DEH-065

200 Ampere Expansion Kit (H, K, R Fuses) GEH-5889


Handle and Load Base Replacements on Fusible Switches
Handle Replacement: 400-1200 Ampere Switches GEH-5553
A-Series II Panelboards
Load Base Replacement for Type ADS 400-600 Ampere Switches GEH-5576 Lighting Panel Rating Labels DEH-40007
Miscellaneous GE Panelboards DEA-185
Typical - Fusible Mains and Feeders DE-166 Stainless Steel Enclosures DET-386
Technical Data, Spectra Series Panelboards - Pressure Locked AD Plus Lighting Panelboards DEP-131
Connectors DE-168
UL Recognized Series Connected Ratings DET-008

Spectra Series Plug-In (Only)


A-Series II Lighting Control Panel
Circuit Breaker Mounting Instructions (Modules)
TKM, THKM, TK4V, LA, SKPA GEH-5623 Lighting Control Panel Catalog/Selection Guide DEA-388

TJK, TJD, TJJ, THJK, TJ4V, THJ4V, TJL4V GEH-5624 Fact Sheet DET-398

TEB, TED, THED, TEL, SEDA, SEHA, SELA, SEPA GEH-5625


TFJ, TFK, THFK, TFL, SFHA, SFLA, SEPA GEH-5626
Pro-Stock Panelboard
TQD, THQD GEH-5643
Selection and Pricing Guide DEP-104A
SGDA, SGHA, SGLA, SGPA (3 pole) GEH-5673
Fact Sheet DET-233
SGDA, SGHA, SGLA, SGPA (2 pole) GEH-5674
Product Summary DEE-240
THLC2, THLC4, TLB4 (3 pole) GEH-5675
Initial Stock Order Form DEZ-176
Circuit Breaker Mounting Hardware Kits
TQD, THQD, SE TEB, TED, THED, THLC1, SF, TFJ, TFK, THFK, SG, Branch Breaker Recommended Stock List DEE-241
TJK, THJK, TJD, TJJ, THLC2, THLC4 GEH-5913 Pro-Stock Literature Order Form DEZ-178
Installing Lugs Sell Sheet DEA-232
Type AML Main Lug Kits GEH-5588 New Product Commercialization Summary DEE-240
Type AML Feed Thru Main Lug Kits GEH-5630 Q&A DEQ-068

Rev. 7/13 www.geindustrial.com BuyLog Catalog 11-53


Data subject to change
without notice
Panelboards Section 11

NOTES:

11-54 BuyLog Catalog www.geindustrial.com Rev. 7/13


Data subject to change
without notice
Switchboards Section 12

New from GE!


New Evolution Switchboard integrates the
EntelliGuard GACB up to 6000A.
Enhanced ISB options including 225kVA, Low Noise,
and Ultra Efficient transformers
GenTower switchboards up to 4000A for quick generator
connections

For more information on these products, order publications


from Sections 27 and 28.

Evolution Series Switchboards........................................................12-2


Spectra Series Switchboards ...........................................................12-5
Commercial Metering Switchboards...............................................12-8
Spectra Integrated Switchboard Solutions .............................12-11
GE GenTower Generator Switchboard.........................................12-17
Merchandised and Metering Switchboards
Jiffy II-Spectra .................................................................................12-19
Jiffy III Switchboards.......................................................................12-24

Top 10 Switchboard publications:


Spectra Application Guide GET-8032
Evolution Application Guide DET-773
Spectra Quick Reference Guide DE-280
Evolution Quick Reference Guide DEE-572
GenTower Quick Reference Guide DEA-504
Commercial Metering DEA-552
Selectivity Tables DET-76
Selectivity Design & XF Templates DET-654
Spectra Installation Manual GEH-5875
Evolution Installation Manual GEH-5876

Rev. 11/13 www.geindustrial.com BuyLog Catalog 12-1


Data subject to change
without notice
Switchboards Section 12
Evolution Series Switchboards

Product Introduction
Evolution Series Switchboards offer a state-of-the-art design
that provides the high quality, safety and reliability long associ-
ated with GE group-mounted switchboards. Evolution Series
Switchboards are designed and manufactured to meet the
stringent GE internal standards along with NEMA, NEC, UL and
cUL requirements. In addition, Spectra RMS and Record Plus
Circuit Breakers meet all NEMA, NEC, IBC Seismic, UL and cUL
requirements, plus those for JIS and IEC.

Class 1

Group-Mounted Main and Feeders


Front-Connected
1200A Main maximum
1200A Feeders maximum
Rear alignment standard
Minimum depth 25"
Main lugs to 2000A
May be mounted against wall

Main and Feeder Devices Group-Mounted


Molded case circuit breakers
Fusible switches type ADS (plug-in style only)
Spectra RMS molded case circuit breakers
Spectra RMS molded case circuit breakers with
microEntelliGuard trip units
Note: Evolution Switchboards feature pre-installed Record Plus molded case circuit breakers
splicing as well as front connected neutrals and grounds Current-limiting circuit breakers
Integral ground fault, protective relay functions,
network communications, ground fault alarm,
neutral protection, ZSI and waveform capture available
with microEntelliGuard.

For more information refer to the following publications:


Evolution Switchboard Application Guide DET-773
Switchboard Quick Reference Guide DEE-572

12-2 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Switchboards Section 12
Evolution Series Switchboards

Integral ground fault, protective relay functions,


network communications, ground fault alarm, neutral protection,
ZSI and waveform capture available with microEntelliGuard.

Class 2

Individually-Mounted Main, Group-Mounted Feeders


Front Accessible or Front/Rear
6000A Main maximum (EntelliGuard) Class 5
1200A group-mounted feeders maximum
Rear alignment standard or front and rear alignment Individually-Mounted Mains and Feeders
Utility CT Compartments 800A - 4000A
Main lugs to 6000A HPC Switch
Depths: Mains 25" - 60" Feeders 25 minimum PowerBreak II
Plug-In or Bolt-On Construction for group-mounted feeders 400A - 1200A
Spectra Breaker
Mains Individually-Mounted 400 - 600A Record Plus
Power Break II insulated case circuit breakers 400A - 6000A EntelliGuard Breaker (Main, Tie and
800 - 4000A with Power+ or EntelliGuard trip units
Feeder Devices)
High pressure contact switches 800 - 4000A
Integral ground fault with Spectra Series, Note: For applications requiring insulated/isolated bus,
Power Break Series and EntelliGuard generator control and extensive relaying refer to AV-3
Integral protective relay functions with EntelliGuard TU or PowerBreak.
Integral POWER LEADER network communications
with EntelliGuard TU
EntelliGuard low voltage power circuit breakers
up to 6000A

Feeder Devices, Group-Mounted


Molded case circuit breakers
Fusible switches type ADS (plug-in style only)
Spectra RMS molded case circuit breakers
Spectra RMS molded case circuit breakers with
microEntelliGuard trip units
Record Plus molded case circuit breakers
Current-limiting circuit breakers

Rev. 11/13 www.geindustrial.com BuyLog Catalog 12-3


Data subject to change
without notice
Switchboards Section 12
Evolution Series Switchboards

GE Evolution Switchboards Standards


Class 1 GE switchboards are manufactured to meet specific quality
Available Devices
standards using standardized components. They meet the
Description Function Type Rating (Amps) following standard:
Group mountedmains and feeders MCCB 1200 (a) Underwriters Laboratories No. UL891.
Main Note: GE switchboards are constructed to this standard as to
Rear alignment standard ADS 1200
Front accessible MCCB 1200 enclosure, busing, wiring and clearances. Only switchboards or
Feeders
Max. 1200-amp mains1200-amp feeders ADS 1200 switchboard sections containing all UL Listed devices can be
UL labeled.
(b) NEMA Standard PB2-latest issue.
Evolution Class 2 (c) CSA
Available Devices
Description Function Type Rating (Amps)
Short-circuit Rating
Individually mounted mains MCCB 1200
Group mounted feeders ADS 1200
The standard main or vertical bus in each switchboard is alu-
Rear alignment standard HPC 4000
minum (copper optional) braced for an integrated equipment
Main section side or rear
Main rating of 65,000 rms symmetrical amperes. When required, bus
PB II 4000
accessible standard bars can be furnished braced for higher short-circuit currents.
Feeder sections-front access EntelliGuard 6000
Max. 6000-amp mains1200-amp feeders
Utility metering compartment MCCB 1200 Ground Bus
Feeders
ADS 1200 Ground bus is furnished as standard.
1
Not UL labeled.

Space and Busing for Future


When space only is required for future addition of any specified
feeder device in a GE switchboard, corresponding vertical bus
and blank filler plate will be furnished. Device mounting hard-
ware may be included, when specified in speedi.

Blank Space Only


When blank space is specified for any class of GE switchboard,
corresponding vertical bus, device mounting, and connecting
straps will not be furnished.

12-4 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Switchboards Section 12
Spectra Series Switchboards

Product Introduction
Spectra Series Switchboards offer a state-of-the-art design that
provides the high quality, safety and reliability long associated
with GE group-mounted switchboards. Spectra Series
Switchboards are designed and manufactured to meet the strin-
gent GE internal standards along with NEMA, NEC, UL and cUL
requirements. In addition, Spectra RMS and Record Plus Circuit
Breakers meet all NEMA, NEC, IBC Seismic, UL and cUL require-
ments, plus those for JIS and IEC.

Class 1

Group-Mounted Main and Feeders


Front-Connected
1200A Main maximum
1200A Feeders maximum
Rear alignment standard
Minimum depth 25"
Main lugs to 2000A
May be mounted against wall

Main and Feeder Devices Group-Mounted


Molded case circuit breakers
Fusible switches type ADS (Spectra plug-in only)
Spectra RMS molded case circuit breakers
Spectra RMS molded case circuit breakers with
microEntelliGuard trip units
Record Plus molded case circuit breakers
Current-limiting circuit breakers
Integral ground fault, protective relay functions,
network communications, ground fault alarm, neutral protection,
ZSI and waveform capture available with microEntelliGuard.

For more information refer to the following publications:


Spectra Switchboard Application Guide GET-8032B
Spectra Switchboard Quick Reference Guide DE-280C

Rev. 11/13 www.geindustrial.com BuyLog Catalog 12-5


Data subject to change
without notice
Switchboards Section 12
Spectra Series Switchboards

Integral ground fault, protective relay functions,


network communications, ground fault alarm, neutral
protection, ZSI and waveform capture available with
microEntelliGuard.

Class 2

Individually-Mounted Main, Group-Mounted Feeders


Front Accessible or Front/Rear
5000A Main maximum (WavePro)
1200A group-mounted feeders maximum
Rear alignment standard or front and rear alignment Class 5
Utility CT Compartments
Main lugs to 6000A Individually-Mounted Mains and Feeders
Depths: Mains 25" - 60" Feeders 25 minimum
Plug-In or Bolt-On Construction for group-mounted feeders 800A - 4000A
HPC Switch
Mains Individually-Mounted PowerBreak II
Power Break II insulated case circuit breakers 800 - 4000A with 400A - 1200A
Power+ or EntelliGuard trip units Spectra Breaker
High pressure contact switches 800 - 4000A 800A - 4000A Bolted Pressure Switch
Integral ground fault with Spectra Series, Power Break Series and 800A - 5000A WavePro Breaker
WavePro (Mains & Tie Devices only)
Integral protective relay functions with EntelliGuard TU
Note: For applications requiring insulated/isolated bus,
Integral POWER LEADER network communications with generator control and extensive relaying refer to AV-3
EntelliGuard TU or PowerBreak.
Bolted Pressure Switches 800 - 4000A
WavePro low voltage power circuit breakers

Feeder Devices, Group-Mounted


Molded case circuit breakers
Fusible switches type ADS (Spectra plug-in only)
Spectra RMS molded case circuit breakers
Spectra RMS molded case circuit breakers with
microEntelliGuard trip units
Record Plus molded case circuit breakers
Current-limiting circuit breakers

12-6 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Switchboards Section 12
Spectra Series Switchboards

GE Spectra Switchboards Standards


Class 1 GE switchboards are manufactured to meet specific quality
Available Devices
standards using standardized components. They meet the
Description Function Type Rating (Amps) following standard:
Group mountedmains and feeders MCCB 1200 (a) Underwriters Laboratories No. UL891.
Main Note: GE switchboards are constructed to this standard as to
Rear alignment standard ADS 1200
Front accessible MCCB 1200 enclosure, busing, wiring and clearances. Only switchboards or
Feeders
Max. 1200-amp mains1200-amp feeders ADS 1200 switchboard sections containing all UL Listed devices can be
UL labeled.
(b) NEMA Standard PB2-latest issue.
Spectra Class 2 (c) CSA
Available Devices
Description Function Type Rating (Amps)
Short-circuit Rating
Individually mounted mains MCCB 1200
Group mounted feeders ADS 1200
The standard main or vertical bus in each switchboard is alu-
Rear alignment standard HPC 4000
minum (copper optional) braced for an integrated equipment
Main section side or rear
Main rating of 65,000 rms symmetrical amperes. When required, bus
X/PB II 4000
accessible standard bars can be furnished braced for higher short-circuit currents.
Feeder sections-front access WavePro 5000
Max. 4000-amp mains1200-amp feeders BPS 4000/5000 1
Utility metering compartment MCCB 1200 Ground Bus
Feeders
ADS 1200 Ground bus is furnished as standard.
1
Not UL labeled.

Space and Busing for Future


When space only is required for future addition of any specified
feeder device in a GE switchboard, corresponding vertical bus
and blank filler plate will be furnished. Device mounting hard-
ware may be included, if selected in speedi.

Blank Space Only


When blank space is specified for any class of GE switchboard,
corresponding vertical bus, device mounting, and connecting
straps will not be furnished.

Rev. 11/13 www.geindustrial.com BuyLog Catalog 12-7


Data subject to change
without notice
Switchboards Section 12
Group Mounted Switchboards
Commercial Metering Switchboard
EUSERC West Coast Utility Applications
NONEUSERC Utility Applications
Lever Bypass

GE Commercial Metering Switchboards are designed specifically to serve


the EUSERC market in the western United States. In addition, they serve the
NON-EUSERC markets with a Lever By-Pass arrangement. They are UL
listed and labeled and offer a wide range of installation and performance
features that simplify any project.
Metering sections are assembled with two sockets pre-wired on the line
and load sides. All sockets are 200A continuous duty. A full selection of
tenant mains are available including circuit breakers, fusible switches and
T-Fuse pullouts.

Standards
Switchboard
UL 891
NEMA PB-2
Meter Sockets
UL 414
ANSI C12.7
Circuit Breakers
For application and size information, refer to publication
UL 489 DEA-552, www.geindustrial.com, or contact your local Sales Office.
Fused Switches
UL 98

Other Key Features


4000 main service, 480V maximum
Aluminum or copper bus
65,000A symmetrical bracing standard; 200K available
200A continuous duty sockets
Hot and cold sequencing is available
Type 3R construction available

Available Sections
Underground Pull Sections
Underground Pull Section with Main Switch
Underground Pull Section with Main Breaker
Overhead Sections with Main Switch or Breaker
CT Meter Sections with Main Switch
CT Meter Sections with Main Switch and Distribution
CT Meter Sections with Main Breaker
CT Main Sections with Main Breaker and Distribution
CT Meter Sections with Main Lugs
Auxiliary Sections (Wireways, Corner Sections)
Multi Meter Sections with Fusible Pullout Mains
Multi Meter Sections with Circuit Breaker Mains
Distribution Sections

12-8 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Switchboards Section 12
Group Mounted Switchboards
Commercial Metering Switchboard
Section Types
UL Listed, EUSERC, Louisville Gas and Electric, KY Approved
208Y/120V, 240Y/120V or 480Y/277V
100 kAIC, 150 kAIC up to 4000A, 200 kAIC at 3000A and 4000A
400, 600, 800, 1000, 1200, 2000, 3000, 4000A
NEMA 1 or 3R enclosure
Bottom feed, center feed, and top busway
Cu or Al bus
Refer to Speedi for all sizing
Half Height Pull Sections
Underground Pull Sections Top Incoming Busway with Single Main Breaker
100 kAIC 400A-4000A 400A-2000A
Bottom feed NEMA 1 or 3R G, K and PBII circuit breakers
Cu or Al bus HPC and BPS fused switches
NEMA 1 or 3R Device padlocking
SE Barriers
Equipment groundfault
protection on 1200A-2000A
(optional on 400A-1000A)
Front access

Large Tenant Metering Distribution Panel


Hot Sequence Metering Interior 2000A, Cu bus,
SG, SK, PBII, BPS, HPC 100 kAIC
Bottom or top exit 13, 18x distribution space
Device padlocking Bolt-on and plug-in
Equipment ground fault protection 3Ph 4W
Mounting provisions for CTs Spectra main breaker or
Isolating barriers main lug only interior
Hinged sealable cover CT compartment up to
Transformer rated meter socket 2000A
Front access Front neutral access
Middle or bottom mounted neutral Submains
Lever bypass meter sockets available
Submains
Rear load wire way spacing 8 minimum

Small Tenant Metering


Cold and hot sequences Middle or bottom mounted neutral
Tenant disconnects SF, T-fuse pullout J Ringless style meter sockets
fuse constructions: Lever bypass meter sockets available
- SF (100A, 200A) Service entrance barriers
- T-fuse pull out (100A, 200A) 100 kAIC
3Ph 4W Service Top and bottom feed exit
3 pole, 2 pole disconnects Test bypass block meter socket available
600A-4000A horizontal bus Ringless cover - NO hinge (ST only)
3-pack 20 width, 6-pack 35 width 5, 7, 13 jaw sockets
25 minimum depth for top or Locking jaws
bottom exit - to 60 Flash shields
Provisions for field installable socket Line lugs at top, customer load connection at
and breaker additions bottom
Front access Small tenant meters; 3- or 6-pack
100% rated neutral; standard ground rating All disconnects lockable in OFF position
Rear load wire way spacing 3 minimum

Rev. 11/13 www.geindustrial.com BuyLog Catalog 12-9


Data subject to change
without notice
Switchboards Section 12
Group Mounted Switchboards
Commercial Metering Switchboard

Side Load Wireway Corner Section


15 minimum width, Copper or aluminum bus
copper or aluminum bus Available in Speedi
In most cases a 15
section will be added on
each side of the corner

UL Approved Field-Installable Small Tenant Kits Meter Spaces


Prewired sections meet UL
Meter Socket
Mounting Plate

Mounting holes
use four (18)
1/ -20 screws
Cover 4
Support
bracket

Meter socket
assembly
[1]

Meter Socket with Device Space Field Kit Meter Socket Space with Device Space Field Kit
Disconnect Rating Product Number Disconnect Rating Product Number
277/480V, 200A CM 203M SB600V 277/480V, 200A CM200A35K480V
35 kAIC Breaker 35 kAIC Breaker
277/480V, 100A CM 103M SB600V 277/480V, 100A CM100A35K480V
277/480V, 200A CM 203M SB600VH 277/480V, 200A CM200A65K480V
277/480V, 100A CM 103M SB600VH 277/480V, 100A CM100A65K480V
120/208V, 200A CM 203M SB240V 120/208V, 200A CM200A65K208V
65 kAIC Breaker 65 kAIC Breaker
120/208V, 100A CM 103M SB240V 120/208V, 100A CM100A65K208V
120/240V, 200A CM 203M SSB240V 120/240V, 200A CM200A65K240V
120/240V, 100A CM 103M SSB240V 120/240V, 100A CM100A65K240V
277/480V, 200A CM 203M STF600V 277/480V, 200A CM200ATF280V
T-Fuse Pullout 120/208V, 200A CM 203M STF240V T-Fuse Pullout 120/208V, 200A CM200ATF208V
120/240V, 200A CM 201M STF240V 120/240V, 200A CM200ATF240V
277/480V, 200A CM 200M SJF600V
FD1 Switch
120/480V, 100A CM 200M SJF240V Notes:
- Small tenant spaces do not get a meter socket nor any wiring
- Provisions do not get a meter socket but they do get wiring

12-10 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Switchboards Section 12
Spectra Series Switchboards
Spectra Integrated Switchboard Solutions

Product Introduction
Spectra Integrated Switchboard solutions save time, money
and space, yet sacrifice nothing in terms of safety, performance
or flexibility. You get flexibility in design and consistency in exe-
cution. Units expand or contract to accommodate your specific
needs. And not only do they reflect GEs rigorous Six Sigma quali-
ty standards, they are also built and tested in accordance with
NEMA PB-2, UL 891 and the NEC. All sections and devices are UL
listed and UL labeled.

Features
Spectra Integrated Switchboard solutions are custom designed Typical Installation Steps for Spectra Integrated
and built to your specifications. You choose all the elements you Switchboard Solution
need. Featured elements include: 1. Bring conduits through floor
Power distribution 2. Receive single units from switchboard lineup
Energy management systems 3. Set switchboard in place (whether the room is complete or not)
Building automation systems 4. Run conduits and wire branches
Surge suppression
Dry type transformers
Lighting controls

Benefits
Save SpaceConventional electrical installations waste space.
Lighting and power panels take up long stretches of wall.
Transformers eat up floor space. Lighting controls and building
automation have to go somewhere. Spectra Integrated
Switchboard solutions integrate all these elements into a frac-
tion of the area.
Reduce Total Installed CostsThe Spectra Integrated
Switchboard solution packs virtually all your power require-
ments into one single integrated distribution and control
systema compact, plug-and-play line-up. This reduces instal-
lation costs while turning otherwise non-productive
mechanical space into revenue-generating sales or storage
space.
Cut Installation TimeConstruction schedules have never
been tighter. When youre ready to install electrical equipment,
you want it done now, so that you can move on to the next
step. Spectra Integrated Switchboard solutions arrive with
everything you need, and when you need it, fully pre-wired to
your specifications. All you have to do is set it in place, run the
incoming power and wire out the branches. Installation takes
less than half the time.

For more information refer to the following publications:


Integrated Switchboard Solutions DEA-373
Integrated Switchboard Planning Tool DEA-486

Rev. 11/13 www.geindustrial.com BuyLog Catalog 12-11


Data subject to change
without notice
Switchboards Section 12
Spectra Series Switchboards
Spectra Integrated Switchboard Solutions
Lighting Panels
A-Series Panel type AQ, AL, AE, AD

A-Series Panel Type AQ, AL, AE, AD


40" Max.
A-Series Panel Height Switchboard Cover Height
UL
19 32
4
25 32
31 36
37 40 X
43 48
49 60

Space available for panels mounting = 84"


58 64
70 76

To determine A-Series Panel height (AQ, AL and AE only), refer to EQIP Sizing 2001.
Hinged covers for lighting panels are available, ask local GE Sales Office

A-Series Panel Specifications


Amperage 400 Amp maximum, MCB or MLO. 49
Voltage 600 Vac maximum
60
Int. Rating 65 kA max., fully or series rating.
Circuits 42 circuits maximum in each panel.
Section Depth 15" to 30"
Section Width 20" to 40"

Maximum panels heights in stack are 36"H and 48"H. 20


If 400 A panel serves as an incoming component then a 4" cover is necessary between the panel and either top X
(for top feed) or bottom (bottom feed)
If 600 A panel serves as an incoming component, then an 8" cover is necessary between the panel and either top Single A-Series Panel
(for top feed) or bottom (bottom feed)
The A-Series panels above 125A must be type M (equipment panel)

40" Max.
A-Series Panel Selection Guide
UL
Amps. Max. Service Information Switchboard Location Section Width Min.
4
AQ panel X
125 A 240 Vac max. Top, Bottom 20W
225 A 1 Ph, 3W. Top, Bottom 20W
400 A 3 Ph, 3W. Top, Bottom 20W
AL panel
125 A 240 Vac max. Top, Bottom 20W
225 A 1 Ph, 3W. Top, Bottom 20W
400 A 3 Ph, 3W. Top, Bottom 20W
AE Panel
125 A 480Y/227 Vac Top, Bottom 20W 37
40 90
225 A 3 Ph, 4W. Top, Bottom 20W
400 A 125/250 Vdc Top, Bottom 20W 4
AD Panel1 X
125 A 120/208 Vac, 3 Ph, 4W. Full Height 25W
225 A 480 Vac, 3 Ph, 3W. Full Height 25W
400 A 480Y/277 Vac, 3 Ph, 4W. Full Height 25W
1Availability limited, ask local GE Sales Office
600 A available, ask local GE Sales Office
31
36
X

Dual A-Series Panel

12-12 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Switchboards Section 12
Spectra Series Switchboards
Spectra Integrated Switchboard Solutions
Transformers

Transformer Specifications
40" Max.
Type 3 Phase, 15-225 kVA
High-Efficiency UL
Windings Copper or Aluminum
Temp. Rise 80C, 115C, 150C
Category Standard
Shield No shield or Electrostatic-Shield1
Enclosure Type NEMA 12
24
No transformer can be placed in a section adjacent to a 150 kVA or 225 kVA
Individual transformers can be placed at the bottom of the section only.
1K-rated transformer, low noise and ultra efficient are also available.
Confirm requirements with local GE Sales Ofice
2N3R available up to 45 kVA max

24
Individual Mounting Logic
ISB Section Size kVA3 XF Frame Size4
30 Wide X 25 Deep 15-45 71, 72, 73, 31, 32, 33
35 Wide X 30 Deep 75-150 74, 75, 34, 35, FC77 XFMR 36
150 KVA Max.
40 Wide X 30 Deep 112.5-225 76, 77, 36, 37
3kVA rangle overlaps due to temp rise, confirm requirements with speedi or in Section 10 of the BuyLog
4Refer to Section 10 of the BuyLog or speedi for more information
36
X

Individual Transformer

Dual Mounting Logic 35" Max.


ISB Section Size Upper XF kVA3 Upper XF kVA3 XF Frame Size4
UL
30 Wide X 25 Deep 15-45 15-45 71, 72, 73, 31, 32, 33
35 Wide X 30 Deep 45-112.5 15-75 74, 75, 34, 35
40 Wide X 30 Deep 112.5 15-75 76, 36
3kVA rangle overlaps due to temp rise, confirm requirements with speedi or in Section 10 of the BuyLog
4Refer to Section 10 of the BuyLog or speedi for more information
42
XFMR
75 KVA Max.

42

42
XFMR
112.5 KVA Max.

42
X

Dual Transformer

Rev. 11/13 www.geindustrial.com BuyLog Catalog 12-13


Data subject to change
without notice
Switchboards Section 12
Spectra Series Switchboards
Spectra Integrated Switchboard Solutions
Stacking Lighting Panels with Transformer

Product Description
Panel type AQ, AL, AE
Panel height 37"H with MCB
Transformer type High-Efficiency, 3 Phase, 15 - 150 kVA
Section size In individual mounting, section depth and width
depend on the transformer.
In double mounting, minimum section width is 40W.
Section depth depends on the transformer.

Transformers can be placed at the bottom of the section only.


Contact local GE Sales Office for Dual Mounted panels with different voltages.

UL UL
4 4
X X X

31
37 40 37
40
4 4

XFMR XFMR
Max. 150 kVA Max. 150 kVA

36 36
X X

A-Series Single Mounting and Transformer A-Series Double Mounting and Transformer

12-14 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Switchboards Section 12
Spectra Series Switchboards
Spectra Integrated Switchboard Solutions
Individual Breakers

Breaker Specifications
Type Spectra RMS SE
Spectra RMS SF
Ampere Rating SE 15-150
SF 70-250
System 3Ph, 3W
3Ph, 4W
Voltage 480 V max.
Section depth 15" min.
Stack with Transformers
Lighting panels
When SE/SF are mounting in stack with transformers, the section size depend on the transformers.
SE/SF individually mounted circuit breakers available, ask local GE Sales Office.

Breaker Dimensions
Minimum size into the section
Type Ampere Rating Height Width
SE 15-70 8H 20W
SE 70-150 8H 20W
SF 70-150 8H 20W
SF 150-250 8H 25W

UL UL

16

16
31
DIST 36
DIST
8
DP-T3
SF
8
8
4
X

XFMR
150 KVA

31
36 36
X X

SE or SF with Transformer SE or SF with Lighting Panels

Rev. 11/13 www.geindustrial.com BuyLog Catalog 12-15


Data subject to change
without notice
Switchboards Section 12
Spectra Series Switchboards
Spectra Integrated Switchboard Solutions
Lighting Contactors and Relays

The minimum section depth required to mount a 463, 260L, or 360ML2 is 15"D.
All other contactors require 20"D section.
Total Box size includes the size of the contactor and necessary wire bending space
required. Contactors are placed at the bottom of the section.

Lighting Contactors
Type: Amps- Valid Section Section Contactor Module UL
Contactor Contactor Combinations Width Depth Width Height
X
CR360L3 30 CR360L3, L4 20-40 15 - 30 5.00 8.58
CR360L4 60 CR360L3, L4 20-40 20 - 30 5.00 10.70
CR463ML 30 CR463ML 20-40 15 - 30 6.66 10.70
CR360L5 100 CR360L5 20-40 20 - 30 7.50 17.45
CR360L6 200 CR360ML400, CR36L6, L7 20-40 25 - 30 11.65 25.74
CR360L7 300 CR360ML400, CR36L6, L7 20-40 25 - 30 12.50 34.90
CR360ML400 400 CR360ML400, CR36L6, L7 20-40 25- 30 12.25 26.90
CR160MC30 30 20-40 20 - 30 10.00 14.30
CR160MC60-75 60-75 CR160MC30, MC60-75, 20-40 20 - 30 10.00 17.45 31
CR160MC100 100 MC100, MC150, 20-40 20 - 30 10.00 19.31 36
CR160MC150 150 MC200, MC225 20-40 20 - 30 10.00 24.50
CR160MC200 200 20-40 20 - 30 10.00 25.70
CR160MC225 225 20-40 20 - 30 10.00 26.90
External ROCB
Controller N/A External ROCB Controller 20-40 20 - 30 10 28
CONTACTORS

Size of standard plates to mount Lighting Contactor and Relays


Height Width
8 20
12 20
16 20 48 H/C
20 25 X
24 25
28 30 Section with Lighting Contactors
32 30
and A-S Panel
36 35
40 35
42 40
48 40

WIRING SPACE

CR463 CR463
WIRING SPACE

Spectra Power PanelboardIndividual Section LIGHTING


CONTACTOR
LIGHTING
CONTACTOR

Type Spectra Panel Bolt-on 8 POLE 8 POLE


Amperage1 1200A max.
Voltage 600 Vac max.
Main MLO or MCB
24
Contact local GE Sales Office for customer metering or individually mounted TVSS. WIRING SPACE
1Panels available up to 2000A, ask local GE Sales Office.
CR463 CR463
WIRING SPACE

LIGHTING LIGHTING
CONTACTOR CONTACTOR
Additional Options
8 POLE 8 POLE
Automatic Transfer Switches - 200A or less

20

Plate with Lighting Contactors

12-16 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Switchboards Section 12
Spectra Series Switchboards
GE GenTower
Generator Switchboard

Product Introduction
For customers who wish to provide their facility with power assurance in
the event of a utility failure or onsite generator failure, the new GE
GenTower offers a stand alone, permanent solution. It provides end cus-
tomers the ability to easily connect a mobile generator to feed the main
power distribution system in the event of a total power failure. Because
the board is permanently installed to the system, there is no need to
make emergency modifications to the building or main distribution board
to connect a generator during the crisis or outage. This saves the build-
ing owner both labor costs and costs associated with down time
at the facility.

The GenTower disconnect can be rated up to 4000 amps and it can be


connected to the existing equipment either by cabling to the lugs on the
main board (provided tap connections are in place), with hard bus con-
nection (to an approved existing GE Switchboard) or through a feeder
breaker in the main board. The stand-alone version comes standard with
a NEMA 3R enclosure, which offers the flexibility to install it at any loca-
tion that may be easily accessed by a mobile generator. It meets UL 891
requirements, and in new installs it can be included as a section within
a standard Spectra Series Switchboard line-up. It is a logical solution
for any commercial or industrial installation where the customer needs
the ability to easily connect a portable generator during a prolonged
power outage, or at a time when the on site generator is out of service
for maintenance.

Product Features and Benefits


Provides a permanent connection point for a portable switchboard and/or the building, and running cable from the
emergency generator generator to the main board
Generator disconnect device ratings up to 4000 amps Reduced down time provides quantifiable productivity savings
at 65k AIC for the customer
Connection options include color-coded, cam-lock quick For safety, the generator disconnect is furnished with provi-
connects and traditional lugs sions to be key interlocked with the main breaker on the typical
Cable supports help maintain proper connection of cables to Switchboard line-up
quick connects Voltages include 120/208V or 480/277V
NEMA 3R enclosure is standard for stand-alone units, optional Rear access versions: 800A, 1000A, 1200A, 1600A, 2000A
for integral units and 2500A
A hinged trap door allows NEMA 3R protection while cables are Front access versions: 800A, 1000A, 1200A, 1600A, 2000A,
connected to the board 2500A, 3000A and 4000A
GenTower can be cabled to main switchboard (provided tap Single section 30-40W x 45-60D x 90H
connections are in place) or direct bus-connected in certain (approx. weight 1,115 lbs)
applications Double section 75-80W x 40-50D x 90H
GenTower can be offered as a section in a new Spectra Series (approx. weight 3,400 lbs)
Switchboard to provide an integral solution Available 10 front extension
Sequence of operation clearly displayed on front cover
Can be installed anywhere space allows, providing options to
choose the best location for mobile generator access For more information refer to the following publications:
Reduces cost and inconvenience associated with providing GenTower Generator Connection Switchboards
temporary generator power such as: modifying the existing and Panelboards DEA-504

Rev. 11/13 www.geindustrial.com BuyLog Catalog 12-17


Data subject to change
without notice
Switchboards Section 12
Group Mounted Switchboards
GE GenTower
Generator Switchboard

Rear Connected, Cable Only Models


Dimensions (inches) Approx. Weight
Enclosure Voltage Amperage Bus Material Description Product Number W D H (lbs.)
NEMA 3R 208/120 800 Cu GQC SWBD 208/120V 800A R N3R GQC208800R3R 30 60 90 1300
NEMA 3R 480/277 800 Cu GQC SWBD 480/277V 800A R N3R GQC480800R3R 30 60 90 1300
NEMA 3R 208/120 1000 Cu GQC SWBD 208/120V 1000A R N3R GQC208100R3R 30 60 90 1300
NEMA 3R 480/277 1000 Cu GQC SWBD 480/277V 1000A R N3R GQC480100R3R 30 60 90 1300
NEMA 3R 208/120 1200 Cu GQC SWBD 208/120V 1200A R N3R GQC208120R3R 30 60 90 1300
NEMA 3R 480/277 1200 Cu GQC SWBD 480/277V 1200A R N3R GQC480120R3R 30 60 90 1300
NEMA 3R 208/120 1600 Cu GQC SWBD 208/120V 1600A R N3R GQC208160R3R 30 60 90 1300
NEMA 3R 480/277 1600 Cu GQC SWBD 480/277V 1600A R N3R GQC480160R3R 30 60 90 1300
NEMA 3R 208/120 2000 Cu GQC SWBD 208/120V 2000A R N3R GQC208200R3R 30 60 90 1525
NEMA 3R 480/277 2000 Cu GQC SWBD 480/277V 2000A R N3R GQC480200R3R 30 60 90 1525
NEMA 3R 208/120 2500 Cu GQC SWBD 208/120V 2500A R N3R GQC208250R3R 40 60 90 1775
NEMA 3R 480/277 2500 Cu GQC SWBD 480/277V 2500A R N3R GQC480250R3R 40 60 90 1775

Front Connected, Cable Only Models


Dimensions (inches) Approx. Weight
Enclosure Voltage Amperage Bus Material Description Product Number W D H (lbs.)
NEMA 3R 480/277 800 Cu GQC SWBD 480/277V 800A F N3R GQC480800F3R 30 45 90 1200
NEMA 3R 208/120 800 Cu GQC SWBD 208/120V 800A F N3R GQC208800F3R 30 45 90 1200
NEMA 3R 480/277 1000 Cu GQC SWBD 480/277V 1000A F N3R GQC480100F3R 30 45 90 1200
NEMA 3R 208/120 1000 Cu GQC SWBD 208/120V 1000A F N3R GQC208100F3R 30 45 90 1200
NEMA 3R 480/277 1200 Cu GQC SWBD 480/277V 1200A F N3R GQC480120F3R 30 45 90 1200
NEMA 3R 208/120 1200 Cu GQC SWBD 208/120V 1200A F N3R GQC208120F3R 30 40 90 1200
NEMA 3R 480/277 1600 Cu GQC SWBD 480/277V 1600A F N3R GQC480160F3R 30 40 90 1200
NEMA 3R 208/120 1600 Cu GQC SWBD 208/120V 1600A F N3R GQC208160F3R 30 50 90 1200
NEMA 3R 480/277 2000 Cu GQC SWBD 480/277V 2000A F N3R GQC480200F3R 30 45 90 1424
NEMA 3R 208/120 2000 Cu GQC SWBD 208/120V 2000A F N3R GQC208200F3R 30 45 90 1424
NEMA 3R 480/277 2500 Cu GQC SWBD 480/277V 2500A F N3R GQC480250F3R 75 45 90 3656
NEMA 3R 208/120 2500 Cu GQC SWBD 208/120V 2500A F N3R GQC208250F3R 75 45 90 3656
NEMA 3R 480/277 3000 Cu GQC SWBD 480/277V 3000A F N3R GQC480300F3R 75 45 90 3701
NEMA 3R 208/120 3000 Cu GQC SWBD 208/120V 3000A F N3R GQC208300F3R 75 40 90 3701
NEMA 3R 480/277 4000 Cu GQC SWBD 480/277V 4000A F N3R GQC480400F3R 80 40 90 3945
NEMA 3R 208/120 4000 Cu GQC SWBD 208/120V 4000A F N3R GQC208400F3R 80 50 90 3945

12-18 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Switchboards Section 12
Group Mounted Switchboards
Merchandised and Metering
Jiffy II-Spectra
EUSERC West Coast Utility Applications

The GE Jiffy II Service Entrance Switchboard is designed especial-


ly to address the requirements of your small project needs. The
compact unit combines the electrical distribution panel, the main
service disconnect and the utility metering compartment into
one space-saving unit, delivering maximum installation
opportunities.
The switchboard is floor mounted and rated up to a maximum
1000A, 100kAIC @ 480V. At 25" deep, the electrical distribution
board easily fits into the tightest areas. A full line of field instal-
lable digital solid state electronic trip molded-case breakers is
also available. With a combination of superior features and
options, the GE Jiffy II not only meets your space saving needs,
but also offers total flexibility in design to meet the requirements
of the project.

Primary Features
Switchboard Styled NEMA Type 1 Indoor or NEMA 3R Enclosure
1000A Heat Rated Bus Max. 100kAIC @ 480V Max.
Ground Fault Protection Optional
Left or Right Hand Pull Sections
Top or Bottom Feed
UL, EUSERC Approved
14X, 18X, 23X of Device Space for Feeder Breakers,
Bolt-on Construction
Seismic IBC Zone 4, CBC Zone 4, UBC Zone 4
Heat Rated Copper Bus
Accepts Aluminum or Copper Incoming Cable
35"W Bolt-on (45"W Plug-in) x 90"H x 25"D (Main Only)
35"W x 90"H x 25"D (Bussed Pull Section)
Add 11" Depth for NEMA 3R

Rev. 11/13 www.geindustrial.com BuyLog Catalog 12-19


Data subject to change
without notice
Switchboards Section 12
Group Mounted Switchboards
Merchandised and Metering
Jiffy II-Spectra
EUSERC West Coast Utility Applications

Instructions 23X Spectra Interior available for Distribution


Drawings Included (Feed to Right STD) For Meter Main applications use suffix MM; includes
Be sure Utility Kit Size matches Distribution Section Add On Lug Kit
Fused Switch Distribution Section 45"W
Fused Distribution Service Disconnect only Example: JF63BCW-MM Jiffy Switchboard 600A Bottom Feed,
No Fusible Main Device available Copper Bus, NEMA 3R, 600A Fused Switch Only, No Distribution

Fused Switch MLO Service Disconnect (6 Handle Rule) 45W

Enclosure Incoming Max. Amp Service Bus Material Product Number


NEMA Type 1 Top Feed 400 A 3PH, 4W Cu JF43TC
NEMA Type 1 Top Feed 600 A 3PH, 4W Cu JF63TC
NEMA Type 1 Top Feed 800 A 3PH, 4W Cu JF83TC
NEMA Type 1 Bottom Feed Pull Section Included 400 A 3PH, 4W Cu JF43BC
NEMA Type 1 Bottom Feed Pull Section Included 600 A 3PH, 4W Cu JF63BC
NEMA Type 1 Bottom Feed Pull Section Included 800 A 3PH, 4W Cu JF83BC
NEMA Type 1 Bottom Feed Pull Section Included 1000 A 3PH, 4W Cu JF103BC
NEMA Type 3R Bottom Feed Pull Section Included 400 A 3PH, 4W Cu JF43BCW
NEMA Type 3R Bottom Feed Pull Section Included 600 A 3PH, 4W Cu JF63BCW
NEMA Type 3R Bottom Feed Pull Section Included 800 A 3PH, 4W Cu JF83BCW
NEMA Type 3R Bottom Feed Pull Section Included 1000 A 3PH, 4W Cu JF103BCW
NEMA Type 3R Top Feed N3R Includes Separate Utility Landing Section 400 A 3PH, 4W Cu JF43TCW
NEMA Type 3R Top Feed N3R Includes Separate Utility Landing Section 600 A 3PH, 4W Cu JF63TCW
NEMA Type 3R Top Feed N3R Includes Separate Utility Landing Section 800 A 3PH, 4W Cu JF83TCW
NEMA Type 3R Top Feed N3R Includes Separate Utility Landing Section 1000 A 3PH, 4W Cu N/A

12-20 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Switchboards Section 12
Group Mounted Switchboards
Merchandised and Metering
Jiffy II-Spectra
EUSERC West Coast Utility Applications

Instructions
Drawings Included (Feed to Right STD)
Be sure Utility Kit Size matches Distribution Section
Breaker Distribution Section 35"W
Breaker Distribution Service Disconnect only
Main Device available on next page
18X Spectra Interior available for Distribution

Breaker MLO Service Disconnect (6 Handle Rule) 35"W

Enclosure Incoming Max. Amp Service Bus Material Product Number


NEMA Type 1 Top Feed 400 A 3PH, 4W Cu JB43TC
NEMA Type 1 Top Feed 600 A 3PH, 4W Cu JB63TC
NEMA Type 1 Top Feed 800 A 3PH, 4W Cu JB83TC
NEMA Type 1 Bottom Feed Pull Section Included 400 A 3PH, 4W Cu JB43BC
NEMA Type 1 Bottom Feed Pull Section Included 600 A 3PH, 4W Cu JB63BC
NEMA Type 1 Bottom Feed Pull Section Included 800 A 3PH, 4W Cu JB83BC
NEMA Type 1 Bottom Feed Pull Section Included 1000 A 3PH, 4W Cu JB103BC
NEMA Type 3R Bottom Feed Pull Section Included 400 A 3PH, 4W Cu JB43BCW
NEMA Type 3R Bottom Feed Pull Section Included 600 A 3PH, 4W Cu JB63BCW
NEMA Type 3R Bottom Feed Pull Section Included 800 A 3PH, 4W Cu JB83BCW
NEMA Type 3R Bottom Feed Pull Section Included 1000 A 3PH, 4W Cu JB103BCW
NEMA Type 3R Top Feed NEMA 3R Includes Separate Utility Landing Section 400 A 3PH, 4W Cu JB43TCW
NEMA Type 3R Top Feed NEMA 3R Includes Separate Utility Landing Section 600 A 3PH, 4W Cu JB63TCW
NEMA Type 3R Top Feed NEMA 3R Includes Separate Utility Landing Section 800 A 3PH, 4W Cu JB83TCW
NEMA Type 3R Top Feed NEMA 3R Includes Separate Utility Landing Section 1000 A 3PH, 4W Cu N/A

Instructions 13X Spectra Interior available for Distribution below Main


Drawings Included (Feed to Right STD) For Meter Main applications use suffix MM; includes
Be sure Utility Kit Size matches Distribution Section Add On Lug Kit
K Frame MCB included
Breaker Distribution Section 35"W Example: JMB63BCW-MM Jiffy Switchboard 600A Bottom Feed,
Main Device included in Section Copper Bus, NEMA 3R, 600A MCB Only, No Distribution

Main Circuit Breaker with Breaker Distribution 35"W

Enclosure Incoming Max. Amp Service Bus Material Product Number


NEMA Type 1 Top Feed 400 A 3PH, 4W Cu JMB43TC
NEMA Type 1 Top Feed 600 A 3PH, 4W Cu JMB63TC
NEMA Type 1 Top Feed 800 A 3PH, 4W Cu JMB83TC
NEMA Type 1 Bottom Feed Pull Section Included 400 A 3PH, 4W Cu JMB43BC
NEMA Type 1 Bottom Feed Pull Section Included 600 A 3PH, 4W Cu JMB63BC
NEMA Type 1 Bottom Feed Pull Section Included 800 A 3PH, 4W Cu JMB83BC
NEMA Type 1 Bottom Feed Pull Section Included 1000 A 3PH, 4W Cu JMB103BC
NEMA Type 3R Bottom Feed Pull Section Included 400 A 3PH, 4W Cu JMB43BCW
NEMA Type 3R Bottom Feed Pull Section Included 600 A 3PH, 4W Cu JMB63BCW
NEMA Type 3R Bottom Feed Pull Section Included 800 A 3PH, 4W Cu JMB83BCW
NEMA Type 3R Bottom Feed Pull Section Included 1000 A 3PH, 4W Cu JMB103BCW
NEMA Type 3R Top Feed NEMA 3R Includes Separate Utility Landing Section 400 A 3PH, 4W Cu JMB43TCW
NEMA Type 3R Top Feed NEMA 3R Includes Separate Utility Landing Section 600 A 3PH, 4W Cu JMB63TCW
NEMA Type 3R Top Feed NEMA 3R Includes Separate Utility Landing Section 800 A 3PH, 4W Cu JMB83TCW
NEMA Type 3R Top Feed NEMA 3R Includes Separate Utility Landing Section 1000 A 3PH, 4W Cu N/A

Rev. 11/13 www.geindustrial.com BuyLog Catalog 12-21


Data subject to change
without notice
Switchboards Section 12
Group Mounted Switchboards
Merchandised and Metering
Jiffy II-Spectra
EUSERC West Coast Utility Applications
Utility Kits

Utility kits include meter door, socket and lugs.

Three-Phase Breaker Width


Utility Voltage Phase Door Width Product Number
ARIZONA PUBLIC SERVICE 120/208V OR 277/480V 3P4W 35 J335APS
LADWP 120/208V OR 277/480V 3P4W 35 J335LADWP
NEVADA POWER 120/208V OR 277/480V 3P4W 35 J335NP
PACIFIC GAS & ELECTRIC 120/208V OR 277/480V 3P4W 35 J335PG&E
PORTLAND GEN ELECTRIC 120/208V OR 277/480V 3P4W 35 J335POGE
PUGET SOUND ENERGY 120/208V OR 277/480V 3P4W 35 J335PSE
SACRAMENTO MUNICIPAL 120/208V OR 277/480V 3P4W 35 J335SME
SALT RIVER PROJECT 120/208V OR 277/480V 3P4W 35 J335SRP
SAN DIEGO GAS & ELECTRIC 120/208V OR 277/480V 3P4W 35 J335SDG&E
SEATTLE CITY LIGHT 120/208V OR 277/480V 3P4W 35 J335SCL
SOUTHERN CAL EDISON 120/208V OR 277/480V 3P4W 35 J335SCE
TUCSON ELECT POWER 120/208V OR 277/480V 3P4W 35 J335TEP

Three-Phase Fusible Width


Utility Voltage Phase Door Width Product Number
ARIZONA PUBLIC SERVICE 120/208V OR 277/480V 3P4W 45 J345APS
LADWP 120/208V OR 277/480V 3P4W 45 J345LADWP
NEVADA POWER 120/208V OR 277/480V 3P4W 45 J345NP
PACIFIC GAS & ELECTRIC 120/208V OR 277/480V 3P4W 45 J345PG&E
PORTLAND GEN ELECTRIC 120/208V OR 277/480V 3P4W 45 J345POGE
PUGET SOUND ENERGY 120/208V OR 277/480V 3P4W 45 J345PSE
SACRAMENTO MUNICIPAL 120/208V OR 277/480V 3P4W 45 J345SM
SALT RIVER PROJECT 120/208V OR 277/480V 3P4W 45 J345SRP
SAN DIEGO GAS & ELECTRIC 120/208V OR 277/480V 3P4W 45 J345SDG&E
SEATTLE CITY LIGHT 120/208V OR 277/480V 3P4W 45 J345SCL
SOUTHERN CAL EDISON 120/208V OR 277/480V 3P4W 45 J345SCE
TUCSON ELECT POWER 120/208V OR 277/480V 3P4W 45 J345TEP

Single-Phase Breaker Width


Utility Voltage Phase Door Width Product Number
ARIZONA PUBLIC SERVICE 120/240V 1P3W 35 J135APS
LADWP 120/240V 1P3W 35 J135LADWP
NEVADA POWER 120/240V 1P3W 35 J135NP
PACIFIC GAS & ELECTRIC 120/240V 1P3W 35 J135PG&E
PORTLAND GEN ELECTRIC 120/240V 1P3W 35 J135POGE
PUGET SOUND ENERGY 120/240V 1P3W 35 J135PSE
SACRAMENTO MUNICIPAL 120/240V 1P3W 35 J135SM
SALT RIVER PROJECT 120/240V 1P3W 35 J135SRP
SAN DIEGO GAS & ELECTRIC 120/240V 1P3W 35 J135SDG&E
SEATTLE CITY LIGHT 120/240V 1P3W 35 J135SCL
SOUTHERN CAL EDISON 120/240V 1P3W 35 J135SCE
TUCSON ELECT POWER 120/240V 1P3W 35 J135TEP

Single-Phase Fusible Width


Utility Voltage Phase Door Width Product Number
ARIZONA PUBLIC SERVICE 120/240V 1P3W 45 J145APS
LADWP 120/240V 1P3W 45 J145LADWP
NEVADA POWER 120/240V 1P3W 45 J145NP
PACIFIC GAS & ELECTRIC 120/240V 1P3W 45 J145PG&E
PORTLAND GEN ELECTRIC 120/240V 1P3W 45 J145POGE
PUGET SOUND ENERGY 120/240V 1P3W 45 J145PSE
SACRAMENTO MUNICIPAL 120/240V 1P3W 45 J145SM
SALT RIVER PROJECT 120/240V 1P3W 45 J145SRP
SAN DIEGO GAS & ELECTRIC 120/240V 1P3W 45 J145SDG&E
SEATTLE CITY LIGHT 120/240V 1P3W 45 J145SCL
SOUTHERN CAL EDISON 120/240V 1P3W 45 J145SCE
TUCSON ELECT POWER 120/240V 1P3W 45 J145TEP

12-22 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Switchboards Section 12
Group Mounted Switchboards
Jiffy III Switchboards

Product Introduction
The GE Jiffy III Utility Service Entrance Switchboard is designed
especially to address the Canadian market. The compact unit
combines the electrical distribution panel, the main service
disconnect and the utility metering compartment into one
space-saving unit, delivering maximum installation opportunities.
The switchboard is floor mounted and rated up to a maximum
1200A, 42 kAIC @600V. At 15 (381 mm) deep, the electrical
distribution board easily fits into the tightest areas where space
is typically limited. The Jiffy III is UL and cUL1 approved and
meets the seismic requirements of IBC Zone 4 and CBC Zone 4.
Designed and approved specifically for the Canadian Utility
Market 2, the Jiffy III is available with mains rated at 800A, 1000A
and 1200A; 80% and 100% rated (with the exception of 1200A,
which is 80% rated only); and with or without Ground Fault pro-
tection. A full line of field installable Digital Solid State Electronic
Trip Molded-Case Breakers is also available. With a combination
of superior features and options, the GE Jiffy III Utility Service
Entrance Switchboard not only meets your space-saving needs,
but also offers total flexibility in design to meet the requirements
of the project.

Features
Switchboard Styled, Type 1 Indoor Enclosure with Driphood
(NEMA 1)
1200AHeat Rated Bus max., 65kAIC @ 600V max.
80% and 100% Rated Main (1200A rated at 80% only)
Ground Fault Protection optional
Left or Right Hand Pull Sectionsdependent on region
Top or Bottom Feed Maindependent on region
UL, cUL approved
23X of Device Space for Feeder Breakers, Bolt-on Construction
Seismic IBC Zone 4, CBC Zone 4, UBC Zone 4
Heat Rated Aluminum Bus Bar standard with Copper Main
Device Straps
Accepts Aluminum or Copper Incoming Cable
40 W (1016 mm) x 90 H (2286 mm) x 15 D (381 mm)
(Main Only)
25 W (635 mm) x 90 H (2286 mm) x 15 D (381 mm)
(Bussed Pull Section)
15 W (381 mm) x 90 H (2286 mm) x 15 D (381 mm)
(Blank Pull Section)
Branch FeedMCCB 15-1200A
1cUL certified to meet CSA 22.2 No. 31.
2Non-BC Hydro Utilities. Contact your local GE Sales Engineer for your
utility requirements.

Rev. 11/13 www.geindustrial.com BuyLog Catalog 12-23


Data subject to change
without notice
Switchboards Section 12
Group Mounted Switchboards
Jiffy III Switchboards

Switchboard with Bussed Section1Left to Right Feed Switchboard w/out Bussed Pull Section1Top Feed
Max. Main Breaker Ground Fault Product Max. Main Breaker Ground Fault Product
Amp Rating Protection Number Amp Rating Protection Number
800 80% No ACJ208080LR 800 80% No ACJ108080T
800 80% Yes ACJ208080GLR 800 80% Yes ACJ108080GT
800 100% No ACJ208100LR 800 100% No ACJ108100T
800 100% Yes ACJ208100GLR 800 100% Yes ACJ108100GT
1000 100% No ACJ210100LR 1000 100% No ACJ110100T
1000 100% Yes ACJ210100GLR 1000 100% Yes ACJ110100GT
1200 80% No ACJ212080LR 1200 80% No ACJ112080T
1200 80% Yes ACJ212080GLR 1200 80% Yes ACJ112080GT

Switchboard with Bussed Section1Right to Left Feed Switchboard w/out Bussed Pull Section1Bottom Feed
Max. Main Breaker Ground Fault Product Max. Main Breaker Ground Fault Product
Amp Rating Protection Number Amp Rating Protection Number
800 80% No ACJ208080RL 800 80% No ACJ108080B
800 80% Yes ACJ208080GRL 800 80% Yes ACJ108080GB
800 100% No ACJ208100RL 800 100% No ACJ108100B
800 100% Yes ACJ208100GRL 800 100% Yes ACJ108100GB
1000 100% No ACJ210100RL 1000 100% No ACJ110100B
1000 100% Yes ACJ210100GRL 1000 100% Yes ACJ110100GB
1200 80% No ACJ212080RL 1200 80% No ACJ112080B
1200 80% Yes ACJ212080GRL 1200 80% Yes ACJ112080GB
1Bus materialaluminum with copper main device straps. Bussed pull sections are
not convertible from left to right or right to left. Main breaker included in section.

Specifications
Product Capability/Specification Jiffy III Switchboard Additional Information
Enclosure Type NEMA 1 NEMA 1 with Driphood
Section Dimensions 40 W x 90 H x 15 D (1016 mm x 2286 mm x 381 mm) (Main Only)
25 W x 90 H x 15 D (635 mm x 2286 mm x 381 mm) (Bussed Pull Section)
15 W x 90 H x 15 D (381 mm x 2286 mm x 381 mm) (Blank Pull Section)
Voltage 600V Max.
Amperage 1200A - Heat Rated
Bus Bar Aluminum with Copper Main Device Straps
80% Rating 800A to 1200A
100% Rating 800A to 1000A
Standards cUL, NEMA, NEC, PB II
Seismic Rating IBC Zone 4, CBC Zone 4, UBC Zone 4
Entry Cable or Bussed Pull Section
Top or Bottom Feed Top and Bottom Feed
Lug Type Mechanical Aluminum
Incoming Cable Copper or Aluminum
Max. Bus kA Rating 65kAIC
Neutral Rating 100% - Heat Rated
Main Devices 1200A
Manually Operated
Stationary
Main Device Accessories UV2, ST2, Aux Contact, Bell Alarm Field Installed
Utility CT Provision Bar Type CT
Utility PT Provision Yes
Branch/Feeder Switches MCCB 15 1200A TEY, TED, TED6CL, THED, TEDL, SFHA
SGLA, SFDA, SFHA, SKHA, SKLA
Field Installed
Branch Accessories UV2, ST2, Aux Contact, Bell Alarm Field Installed
Branch Mounting 23x Bolt-on Construction
Delivery Time 2 Weeks to Ship - 3 Weeks On-site
Accessories Available Jiffy and Spectra Bolt-on Device Mounting Hardware
Full Filler Plates for Jiffy and Spectra
Jiffy and Spectra Bolt-on Device Filler Plate Kit
Padlocking Devices for Jiffy and Spectra
Load Lugs
2Shunt Trip or UV cannot be installed in same breakers.

12-24 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Section Updated 12 / 2016
Busway Section 13

MicroVersaTrip Plus Trip Units with 4WGF protection in


bus plugs
Joint-Guard Protection System:
GE invention dynamically indicates proper torque with color.
Means easy installation and easy maintenance!
Custom Colors available for unique applications.
Style II Outdoor Spectra Series Design reduces joint installa-
tion time by 50% with improved joint cover spring-latch clamp-
ing system. This feature is also standard on splash-proof and
drip-proof designs. Ask about the free installation DVD (DEV-066).
Weathershield Epoxy Joint Insulators provided as standard on
Style II Spectra Series Outdoor (NEMA 3R) and Splash-proof
designs (IP54 and IP65/66).

Busway Overview ....................................................................................13-2 Flex-A-Power Busway


Busway Short-Circuit Ratings ............................................................13-3 Aluminum Conductors........................................................................13-66
Busway Plug Short-Circuit Ratings..................................................13-4 Copper Conductors..............................................................................13-68
Spectra Series Busway, Sandwich Bus Type DH Plugs.........................................................................................13-70
Application ..................................................................................................13-5 Dimensions...............................................................................................13-73
Aluminum Conductors ..........................................................................13-8 LW Busway
Copper Conductors..............................................................................13-12 Replacement Parts, Application.....................................................13-74
Spectra RMS Busway, Sandwich Bus Replacement Parts, Dimensions....................................................13-76
Circuit Breaker Busway Plugs .........................................................13-20 Type LTG Plug-in, Application ..........................................................13-78
Circuit Breaker with MicroVersaTrip Plus Trip Units...........13-25 Outlines and Dimensions ..................................................................13-80
Spectra Series Busway, Sandwich Bus Armor-Clad Busway
Plugs, Fusible, Conversion Kits........................................................13-29 Transition Sections and Accessories ...........................................13-81
Plug Options ............................................................................................13-33 Busway Plugs..........................................................................................13-82
Outlines, Dimensions and Weights...............................................13-35 Options and Additions ........................................................................13-87
Spectra Series Busway, Low Amp Flex-A-Power Busway
Application and Product Numbers ...............................................13-44 Types FVA, FVK and LVDP Application.........................................13-88
Aluminum Conductors........................................................................13-46 Busway Plugs..........................................................................................13-91
Copper Conductors..............................................................................13-50 Outlines and Dimensions ..................................................................13-94
Circuit Breaker Busway Plugs .........................................................13-58 Type DE Busway
Outlines, Dimensions and Weights...............................................13-62 Plugs for Obsolete DE Busway........................................................13-95

Rev. 11/13 www.geindustrial.com BuyLog Catalog 13-1


Data subject to change
without notice
Busway Section 13
General
General Electric is a world leader in busway manufacturing and Standards
design, providing a wide range of busway types available from There are published standards for all types of low-voltage
30 to 5000 amperes and up to 600 Volts ac. busway. GE busway conforms to the latest revision of
GE busway has many advantages over wire and conduit: NEMA Standard BU 1, UL standard 857 Federal Specification
Lower total installed cost. Busway material costs are often W-B-811b, CSA. GE busway bears the UL label except where
equal or less than wire and conduit, and contractors can otherwise noted.
install busway in a fraction of the time.
Lower life cycle cost. Busway components can be added, High-Frequency Applications
deleted, or relocated one month or even many years after
the initial installation, saving time and money. GE busway can be used at higher than 60-cycle frequency, but in
Predictable characteristics. Busway systems conform to most cases it is necessary to derate the busway. In most busway,
common standards. Consultants can use readily published the voltage drop increases at higher frequencies.
data on busway short-circuit ratings, voltage drop, weights
and dimensions in the planning stage of an electrical project. Short-Circuit Ratings
Can save considerable space in tight electrical closets and
All busway with a UL label must be marked with a UL listed short-
existing buildings.
circuit rating. UL short-circuit ratings apply to all busway and
associated fittings such as straight lengths, elbows, tees, tap
Busway Product Lines boxes, power takeoffs, and plugs which are necessary for a
Spectra Series225-5000 amperes busway installation. Ratings without a ground bar are established
by tests which require the housing and housing joints to provide
Spectra Series LowAmp225-800 amperes a satisfactory ground return.
DH100 amperes The short-circuit rating of fittings with protective devices which
LW(Replacement parts only) are part of the busway, such as power takeoffs and reducers, is
LTG50 amperes, 300 Volts ac/dc equal to the lower of the short-circuit rating of the protective
device or the busway with which the fitting is used. For example,
Armor-Clad(Replacement parts only) a fusible power takeoff rated with 200,000 amperes with Class J
FVA/FVK225-1000 amperes fuses when installed on a busway rated 65,000 amperes would
LVD/LVDP(Replacement parts only) have a rating of 65,000 amperes.

DNSP(Call GE EnergySales Office The short-circuit rating of a busway plug is equal to the short-cir-
for information.) cuit rating of the fuse or circuit breaker used in the plug.

Usage Considerations Busway Publications:


Spectra Series Busway vs. Wire and Conduit GEA-12111
Busway is not designed for use in highly corrosive atmospheres Spectra Series Busway GET-7005E
such as battery rooms or in classified hazardous locations where Spectra Series Busway Installation Instructions DEH-40087C
Spectra Series LowAmp Busway GET-8063
it could be subject to mechanical damage. Busway is not Spectra Series LowAmp Busway Installation Instructions GEH-6436
designed to be embedded in the ground or in concrete and Spectra Series LowAmp Busway vs. Major Competitive Manufacturers DEC-023
should be used only for exposed work. However, most inspection Spectra Series LowAmp Busway Fact Sheet DET-103
GE Type DH Plug-In or Feeder Busway GET-9001A
authorities consider the space above ceiling to be accessible, GE Type DH Busway Installation Instructions GEH-6437
provided the ceiling panels are readily removable. Spectra Series BuswayShort Time Heating Limits GES-9508
Spectra Series Busway, 600-5000 Amp Bus Bar Sizing GEZ-7726
Spectra Series Busway vs. Major Competitor Manufacturers GEZ-7736
Labor Estimating Manual (Busway) GEZ-7737
Ambient Temperature Insulation Integrity DE-171
Spectra Series Outdoor Busway
GE busway is rated based on a 55 hot spot temperature rise Installation Video DEV-051A
over a maximum ambient of 40C. The busway should be derat- Installation DVD DEV-066
ed for high ambient temperatures. Busway Tool Kit DEU-060

Thermal Expansion
Give consideration to the effects of thermal expansion on
busway runs. Compensation for thermal expansion is inherent in
DH busway. For other busway types, expansion fittings may be
necessary for long straight runs of 150 feet or more, particularly
if the busway is not free to move at the ends of the run. The use
of an expansion fitting is recommended when the busway run
crosses a building expansion joint.

13-2 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Busway Section 13
Short-Circuit Ratings
Spectra Series Busway Maximum Fuse Sizes for Increased Short-Circuit Protection
Short-Circuit Ratings Plug-In and Feeder Max "L" Fuse Sizes For
Amperage Increased Short-Circuit Rating
Aluminum (kA) @ Copper (kA) @
Aluminum Copper @100 kA @200 kA
3 6 1 3* 3 6 1 3*
Amperage Cycles Cycles Sec. Secs. Cycles Cycles Sec. Secs.
225 225 1200 1 800 1
400 400 1200 1 800 1
225 50 50 24 14 50 50 36 21
600 1200 1
800 1
400 85 85 24 14 50 50 36 21
1
600 800 2000 1200 1
600 85 85 24 14 85 85 36 21
1000 2000 1
800 100 100 42 24 85 85 36 21
800 1200 2500 1
1000 100 100 50 29 100 100 51 29
1000 1350 2500 1
1200 125 125 62 36 100 100 65 37
1200 1600 3000 1
1350 150 150 84 49 100 100 76 44
1350 2000 4000 1
1600 150 150 95 55 125 125 95 55
1600 4000 1
2000 150 150 121 70 150 150 129 75
2000 2500 4000 1
2500 200 200 132 76 150 150 162 107
1 Also 600J, 800T or 400R.
3000 200 200 169* 97 200 200 191* 110
4000 200 200 200* 140 200 200 200* 149
5000 200 200 200* 200 Maximum Fuse Sizes for Increased Short-Circuit Protection
* Ratings based on calculated values
Max. Fuse Sizes
For Increased Short-Circuit Rating

Spectra LowAmp Busway @100 kA @200 kA


Amperage Class J C lass T C lass R C lass J C lass T C lass R
Plug-In and Feeder Bus
Aluminum
Aluminum (kA) @ Copper (kA) @ 225 600 800 100 400 400 200
3 1 3 3 1 3 400 600 800 400 600 800 400
Amp Rating Cycles Sec. Secs. Cycles Sec. Secs.
600 600 800 600 600 800 400
225 30 11 6 30 17 10 800 600 800 600 600 800 400
400 42 17 10 30 17 10 Copper
600 50 28 16 42 25 15 225 600 800 200 400 400 200
800 50 50 29 50 42 24 400 600 800 200 400 400 200
600 600 800 400 600 800 400
800 600 800 600 600 800 400

Flex-A-Power Type DH Busway3


Type DH Busway has been tested in accordance with NEMA test procedures, to a maximum short-circuit rating of 14,000 rms
amperes symmetrical. When properly protected by a maximum 100 ampere UL listed Class K-1, K-5, or J fuses, the DH Busway may
be applied to a system with a short-circuit available up to the UL listed short-circuit rating of the fuses.

3The adjustable straight length is rated 10 kA.

Rev. 11/13 www.geindustrial.com BuyLog Catalog 13-3


Data subject to change
without notice
Busway Section 13
Plug Short-Circuit Ratings

Fusible Switch Busway Plugs Spectra RMS Circuit Breaker IC Ratings (rms sym. kA)
Frame Type 240 V 480 V 600 V
Fusible switches in all busway fittings (plugs, power takeoffs, and
SED 18 14 14
reducers) have the following short-circuit ratings when used with
SEH 65 25 18
the fuses shown. To qualify for R fuse rating, switches must have SEL 100 65 25
R fuse clips which reject other type fuses. The interrupting rating SEP 200 100 25
SFH 65 25 18
of the fuse must equal or exceed the short-circuit rating of the SFL 100 65 25
switch. It is lower than the short-circuit rating of the switch, then SFP 200 100 25
the combination has the rating of the fuse. SGH4 65 35 25
SGL4 100 65 65
SGP4 200 100 65
Switch Interrupting Rating SGH6 65 35 25
Switch Ampere Fuse Amperes rms Symmetrical SGL6 100 65 65
Type Rating UL Class Description 240 and 480 Volts SGP6 200 100 65
QMR 30 to 1200 H One Time 10,000 SKH 65 50 25
QMR 30 to 1200 K5 High Interrupting 10,000 SKL 100 65 42
QMR 30 to 1200 K1 High Interrupting 10,000 SKP 200 100 65
QMR 30 to 1200 J Current Limiting 200,000
QMR 30 to 1200 R Current Limiting 200,000
QMR 30 to 1200 L Current Limiting 200,000

Circuit Breaker Busway Plugs


Spectra1 Trip Old Trip Spectra Frame 2 Old Frame
Frame Range Frame Range IC Ratings IC Ratings
Construction Type (Amps) Type (Amps) 240 V 480 V 600 V 240 V 480 V 600 V
TEB 15-100 10
SED 15-150 TED4 15-100 18 14 14 18 14
SED 15-150 TED6 15-100 18 14 14 18 14 14
SFH 70-250 TFJ 70-225 65 25 18 25 22 18
SFH 70-250 TFK 70-225 65 25 18 25 22 18
Standard
SGH4 125-400 TJJ 125-400 65 35 25 42 30 22
Frames
SGH4 125-400 TJK4 125-400 65 35 25 42 30 22
SGH6 250-600 TJK6 250-600 65 35 25 42 30 22
SGH6 250-600 TJ4V 150-600 65 35 25 42 30 22
SKH 300-800 TKM8 300-800 65 50 25 42 30 22
SKH 300-800 TK4V 800 65 50 25 42 30 22
SEH 15-150 THED 15-100 65 25 18 65 25 18
SFH 70-250 THFK 70-225 65 25 18 65 25 18
SGH4 125-400 THJK4 125-400 65 35 25 65 35 25
SGH6 250-600 THJK6 400-600 65 35 25 65 35 25
Hi-Break SGH6 250-600 THJ4V 150-600 65 35 25 65 35 25
Frames
SGH6 250-600 TJH 150-600 65 35 25 65 35 25
SKH 300-800 THKM8 300-800 65 60 25 65 35 25
SKH 300-800 TKH 300-800 65 50 25 65 50 25
SEP 15-150 THLC13 15-100 200 100 25 200 150
Fuseless
SFP 70-250 THLC23 125-225 200 100 25 200 150
Current
Limiting SGP4 125-400 THLC43 225-400 200 100 65 200 150
SGP6 250-600 200 100 65
SEL 15-150 TEL3 15-100 100 65 25 100 65 25
SFL 70-250 TFL3 125-225 100 65 25 100 65 25
High SGL4 125-400 TLB43 250-400 100 65 65 85 50
Interrupting SGL6 250-600 TJL4V 150-600 100 65 65 100 65 30
SGL6 250-600 TJL 150-600 100 65 65 100 65 30
SKL 300-800 TKL4V 400-800 100 65 65 100 65 42
SKL 300-800 TKL 800 100 65 65 100 65 42
TB1 15-100 200 200 200
Tri-Break
TB4 125-400 200 200 200
Interrupting
TB6 300-600 200 200 200
TB8 600-800 200 200 200
1Spectra RMS Circuit Breakers UL listed for Spectra Series Busway only.
2UL listed interrupting ratings in thousand amperes rms symmetrical ac volts.
3Discontinued; replaced by Spectra Frame Type.

13-4 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Busway Section 13
Spectra Series Busway
Application

UL Fire-Stop System Cubic Inches Required per Floor and Wall


UL listed three-hour fire-stop barrier is now available for use with
SEALANT 100 FLOOR SEALANT 100 WALL
GE Busway systems. The system is listed in the UL Fire Resistance Amperage Al Cu Al Cu
Directory under section 3L73Through-Penetration Fire-Stop Sys-
225-600 17 17 34 34
tems. In addition to the three-hour test, the system has met the
800 21 17 42 34
criteria of ASTM E814 (UL1479). 1000 22 18 44 42
The contractor installs a mineral wool batt (4 PCF Nominal) as 1200 23 20 46 44
shown below, on-site during the busway installation process. For 1350 27 22 54 46
riser applications, the system is used in combination with a stan- 1600 28 23 56 54
dard GE spring hanger and floor flange. For horizontal applica- 2000 33 27 66 56
tions, the system is used in combination with two wall flanges 2500 46 33 92 66
(one per side). 3000 53 44 106 92
4000 66 53 132 106
5000 66 132
GE Busway
" Thick Minimum
Sealant 100
Floor/Wall
Description Container Product Number
Flange
Top of Floor/Curb Sealant 100 19 cu. in.-Tube SBFB100
or Wall
You have two options for ordering the fire-stop material:

Floor 1. With initial busway purchase. Use the product numbers listed
above and the fire-stop material will be shipped in a specially
marked box directly to the job site with the busway.
Mineral Wool 2. Through 1-800-GE 1-STOP or an authorized GE Silicones
Concrete 4 " 3" Depth Minimum Distributor. Recommended for fill-in (if needed) after
Thick Minimum initial purchase.
This information is provided as a guideline for typical fire-stop
Note: The Busway cover plate and sealant is required on both sides for wall
installation.
systems. If you have an annulus (or opening) greater than 1
beyond the busway enclosure, you will need to determine the
proper amount of fire-stop material based on the illustration on
this page. Quantities are based on application of recommended
amount of material; more may be required if over-application
occurs.

Rev. 11/13 www.geindustrial.com BuyLog Catalog 13-5


Data subject to change
without notice
Busway Section 13
Spectra Series Busway
Application

Spectra Series Busway Seismic Certification Facts Zone 4 Features/Benefits


General Easy Install:
The complete standard commercial offering of Spectra Series New Joint-Guard protection systemdynamically indicates
Busway is certified for ZONE 4 Seismic conditions as witnessed proper torque through color! Easy install and maintenance!
and approved (by the tests performed) at Wyle Laboratories,
Huntsville, Alabama.
Busway Configurations
Both vertical riser and horizontal sections of Spectra Series
Busway were certified to Zone 4 Seismic conditions. The maxi-
mum acceptable parameters are:
Maximum
Acceptable Vertical Riser Horizontal
Parameters Configuration Configuration1
Acceptable Orientations Edgewise & Flatwise

Maximum Ratings 2500A Max Copper 5000A Max Copper


4000A Max Aluminum 4000A Max Aluminum
Maximum Voltage 600 V Max 600 V Max Tight Joint Loose Joint
Service 3- & 4-Wire 3- & 4-Wire
Lighter Weightmeans it installs faster than other busways
Distribution Plug-In & Feeder Plug-In & Feeder
and beats wire and conduit for total installed cost.
Standard Hanger
Standard Floor Flange
System using Single Drop-Rod Hangerper 10-foot section (up to 2500
Hangers Kit with Standard
Spring Hanger Assembly
TRAPEZE HANGERS & Al/1600 Cu amps) ensures easy, fast installation.
CLIPS ONLY
Field-Adjustable Isolation Joint( 1/2 per joint) provides
Maximum 12 feet 10 feet
Hanger Spacing on-site flexibility.
Full Threaded Standard 1/2" Rods Standard 1/2" Rods
Plug-Assistand plug position locator ensure fast, safe,
Drop Rods
accurate plug installation.
Must be BOLTED
Drop Rod Not Applicable through Ceiling/Floor 5-Day Check Piece Programallows you to order busway
Connection1
using standard hardware.1 before you know exact equipment locations. Contact your local
Distribution Equipment Standard Flanged-End Standard Flanged-End Sales Engineer for details.
Connection (Pbd., Swbd, Stub-Special Hardware & Stub-Special Hardware &
Swgr, MCC, etc.) Connections NOT required. Connections NOT required.
Performance/Protection/Maintenance:
Bus Plugs All Types Acceptable All Types Acceptable
Fittings All Types Acceptable All Types Acceptable
Exclusive BlueCoat epoxy insulation(Class B, UL 130C)
Cable Tap Boxes All Types Acceptable All Types Acceptable
provides the industrys best protection (50 years and beyond).
End Boxes All Types Acceptable All Types Acceptable
Earth-Bond Integrated Grounding Systemprovides a lower
Acceptable
resistance ground path than internal ground bars.
Indoor, Drip-Proof, Splash Indoor, Drip-Proof, Splash
Applications &
Proof & Outdoor Proof & Outdoor Highest Short-Circuit Ratingsmean protection and applica-
Constructions
tion flexibility.
Proximity To Walls Standard 1" Standard 1"
1 Drop rods "must" be bolted through ceiling/floor and secured on both Belleville Spring Washerthe industrys best, retains over 90%
sides with standard washers and nuts. of original contact pressure, offering a maintenance-free joint if
torqued properly.
Summary Applications:
These parameters for ZONE 4 seismic conditions are identical to Outdoor Designexclusively meets the industrys highest out-
the standard commercial offering of Spectra Series Busway. door rating. Also meets IP40, IP43, IP54, IP65, IP66. Replaces
Therefore, Spectra Series Busway can be used in applications existing design.
ranging up to ZONE 4 seismic conditions without restrictions, Std. Outdoorwith condensation weep holes is IP54.
special bracing, connections, or hangers. Plus, Spectra Series Outdooris IP65/66.
Busway can connect to equipment (panelboards, switchboards, Seismic Zone 4 Approvedwith no special requirements.
motor control centers, switchgear, etc.) using standard flanged Optional UL Listed Fire-Stopprovides easy code compliance.
end stubs, cable tap boxes, and bus plugs. TVSS Bus Plugsnow available for sensitive applications.
Available Ratings
Amperes: 225 to 5000 amperes AC / up to 8000 amperes DC
Voltage: 600 Volts or less
Busing: Aluminum or Copper
Systems: 3-phase, 3-wire and 3-phase, 4-wire (full neutral)
Enclosures: Indoor, drip-proof, splash proof and outdoor

Contact your local GE Representative for pricing.

13-6 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Busway Section 13
Spectra Series Busway
Sandwich Bus
All Conductors

Spectra Series Busway Product Numbering System

F 3 H A 02 SL I 02
Product Description Code
Feeder F
Type Plug-In 5 P Type Feet Code 6
Riser 5 R 1 01
3PH, 3W 3 2 02
Service 3PH, 4W 4 3 03
100% Neutral
Ground Integrated Housing H 4 04
Copper C Indoor I 5 05
Conductor Feeder
Aluminum A Drip Proof D 0 06
Splash Proof S 7 07
Outdoor O 8 08
Amps Code 9 09
Configurations Code 225 02 10 10
Straight Length SL 400 04 1 01
Elbow Left EL 600 06 2 02
Elbow Right ER 800 08 4 04
Plug-In
Elbow Up EU 1000 10 6 06
Elbow Down ED 1200 12 8 08
Center Cable Tap Box-Up CT 1350 13 10 10
Center Cable Tap Box-Down CB 1600 16 Fittings NA ST
End Cable Tap Box-Up TT 2000 20
End Cable Tap Box-Down TB 2500 25
End Box EB 3000 30
Flanged End FE 4000 40
Flanged End w/Lugs FL
5 Straight lengths only.
6 Code 01 suffix for order entry purposes only. Minimum length 2'-0".

Rev. 11/13 www.geindustrial.com BuyLog Catalog 13-7


Data subject to change
without notice
Busway Section 13
Spectra Series Busway
Sandwich Bus
Aluminum Conductors

225 Amps Three-Phase, Three-Wire 800 Amps Three-Phase, Three-Wire


Integrated Housing Ground Integrated Housing Ground
Component Type Product Number Component Type Product Number
Linear Lengths 10-ft. plug-in P3HA02SLI10 Linear Lengths 10-ft. plug-in P3HA08SLI10
Linear Lengths 10-ft. feeder F3HA02SLI10 Linear Lengths 10-ft. feeder F3HA08SLI10
Linear Lengths 10-ft. riser R3HA02SLI10 Linear Lengths 10-ft. riser R3HA08SLI10
Fitting Elbows; Left F3HA02ELIST Fitting Elbows; Left F3HA08ELIST
Fitting Elbows; Right F3HA02ERIST Fitting Elbows; Right F3HA08ERIST
Fitting Elbows; Up F3HA02EUIST Fitting Elbows; Up F3HA08EUIST
Fitting Elbows; Down F3HA02EDIST Fitting Elbows; Down F3HA08EDIST
Accessories End Cable Tap Box (Up) F3HA02TTIST Accessories End Cable Tap Box (Up) F3HA08TTIST
Accessories End Cable Tap Box (Dn) F3HA02TBIST Accessories End Cable Tap Box (Dn) F3HA08TBIST
Accessories Center Cable Tap Box (Up) F3HA02CTIST Accessories Center Cable Tap Box (Up) F3HA08CTIST
Accessories Center Cable Tap Box (Dn) F3HA02CBIST Accessories Center Cable Tap Box (Dn) F3HA08CBIST
Accessories End Box F3HA02EBIST Accessories End Box F3HA08EBIST
Accessories Flanged End w/ Lugs F3HA02FLIST Accessories Flanged End w/ Lugs F3HA08FLIST
Accessories Flanged End F3HA02FEIST Accessories Flanged End F3HA08FEIST

400 Amps Three-Phase, Three-Wire 1000 Amps Three-Phase, Three-Wire


Integrated Housing Ground Integrated Housing Ground
Component Type Product Number Component Type Product Number
Linear Lengths 10-ft. plug-in P3HA04SLI10 Linear Lengths 10-ft. plug-in P3HA10SLI10
Linear Lengths 10-ft. feeder F3HA04SLI10 Linear Lengths 10-ft. feeder F3HA10SLI10
Linear Lengths 10-ft. riser R3HA04SLI10 Linear Lengths 10-ft. riser R3HA10SLI10
Fitting Elbows; Left F3HA04ELIST Fitting Elbows; Left F3HA10ELIST
Fitting Elbows; Right F3HA04ERIST Fitting Elbows; Right F3HA10ERIST
Fitting Elbows; Up F3HA04EUIST Fitting Elbows; Up F3HA10EUIST
Fitting Elbows; Down F3HA04EDIST Fitting Elbows; Down F3HA10EDIST
Accessories End Cable Tap Box (Up) F3HA04TTIST Accessories End Cable Tap Box (Up) F3HA10TTIST
Accessories End Cable Tap Box (Dn) F3HA04TBIST Accessories End Cable Tap Box (Dn) F3HA10TBIST
Accessories Center Cable Tap Box (Up) F3HA04CTIST Accessories Center Cable Tap Box (Up) F3HA10CTIST
Accessories Center Cable Tap Box (Dn) F3HA04CBIST Accessories Center Cable Tap Box (Dn) F3HA10CBIST
Accessories End Box F3HA04EBIST Accessories End Box F3HA10EBIST
Accessories Flanged End w/ Lugs F3HA04FLIST Accessories Flanged End w/ Lugs F3HA10FLIST
Accessories Flanged End F3HA04FEIST Accessories Flanged End F3HA10FEIST

600 Amps Three-Phase, Three-Wire 1200 Amps Three-Phase, Three-Wire


Integrated Housing Ground Integrated Housing Ground
Component Type Product Number Component Type Product Number
Linear Lengths 10-ft. plug-in P3HA06SLI10 Linear Lengths 10-ft. plug-in P3HA12SLI10
Linear Lengths 10-ft. feeder F3HA06SLI10 Linear Lengths 10-ft. feeder F3HA12SLI10
Linear Lengths 10-ft. riser R3HA06SLI10 Linear Lengths 10-ft. riser R3HA12SLI10
Fitting Elbows; Left F3HA06ELIST Fitting Elbows; Left F3HA12ELIST
Fitting Elbows; Right F3HA06ERIST Fitting Elbows; Right F3HA12ERIST
Fitting Elbows; Up F3HA06EUIST Fitting Elbows; Up F3HA12EUIST
Fitting Elbows; Down F3HA06EDIST Fitting Elbows; Down F3HA12EDIST
Accessories End Cable Tap Box (Up) F3HA06TTIST Accessories End Cable Tap Box (Up) F3HA12TTIST
Accessories End Cable Tap Box (Dn) F3HA06TBIST Accessories End Cable Tap Box (Dn) F3HA12TBIST
Accessories Center Cable Tap Box (Up) F3HA06CTIST Accessories Center Cable Tap Box (Up) F3HA12CTIST
Accessories Center Cable Tap Box (Dn) F3HA06CBIST Accessories Center Cable Tap Box (Dn) F3HA12CBIST
Accessories End Box F3HA06EBIST Accessories End Box F3HA12EBIST
Accessories Flanged End w/ Lugs F3HA06FLIST Accessories Flanged End w/ Lugs F3HA12FLIST
Accessories Flanged End F3HA06FEIST Accessories Flanged End F3HA12FEIST

Aluminum, Three-Wire, Housing Ground

13-8 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Busway Section 13
Spectra Series Busway (continued)
Sandwich Bus
Aluminum Conductors

1600 Amps Three-Phase, Three-Wire 3000 Amps Three-Phase, Three-Wire


Integrated Housing Ground Integrated Housing Ground
Component Type Product Number Component Type Product Number
Linear Lengths 10-ft. plug-in P3HA16SLI10 Linear Lengths 10-ft. plug-in P3HA30SLI10
Linear Lengths 10-ft. feeder F3HA16SLI10 Linear Lengths 10-ft. feeder F3HA30SLI10
Linear Lengths 10-ft. riser R3HA16SLI10 Linear Lengths 10-ft. riser R3HA30SLI10
Fitting Elbows; Left F3HA16ELIST Fitting Elbows; Left F3HA30ELIST
Fitting Elbows; Right F3HA16ERIST Fitting Elbows; Right F3HA30ERIST
Fitting Elbows; Up F3HA16EUIST Fitting Elbows; Up F3HA30EUIST
Fitting Elbows; Down F3HA16EDIST Fitting Elbows; Down F3HA30EDIST
Accessories End Cable Tap Box (Up) F3HA16TTIST Accessories End Cable Tap Box (Up) F3HA30TTIST
Accessories End Cable Tap Box (Dn) F3HA16TBIST Accessories End Cable Tap Box (Dn) F3HA30TBIST
Accessories Center Cable Tap Box (Up) F3HA16CTIST Accessories Center Cable Tap Box (Up) F3HA30CTIST
Accessories Center Cable Tap Box (Dn) F3HA16CBIST Accessories Center Cable Tap Box (Dn) F3HA30CBIST
Accessories End Box F3HA16EBIST Accessories End Box F3HA30EBIST
Accessories Flanged End w/ Lugs F3HA16FLIST Accessories Flanged End w/ Lugs F3HA30FLIST
Accessories Flanged End F3HA16FEIST Accessories Flanged End F3HA30FEIST

2000 Amps Three-Phase, Three-Wire 4000 Amps Three-Phase, Three-Wire


Integrated Housing Ground Integrated Housing Ground
Component Type Product Number Component Type Product Number
Linear Lengths 10-ft. plug-in P3HA20SLI10 Linear Lengths 10-ft. plug-in P3HA40SLI10
Linear Lengths 10-ft. feeder F3HA20SLI10 Linear Lengths 10-ft. feeder F3HA40SLI10
Linear Lengths 10-ft. riser R3HA20SLI10 Linear Lengths 10-ft. riser R3HA40SLI10
Fitting Elbows; Left F3HA20ELIST Fitting Elbows; Left F3HA40ELIST
Fitting Elbows; Right F3HA20ERIST Fitting Elbows; Right F3HA40ERIST
Fitting Elbows; Up F3HA20EUIST Fitting Elbows; Up F3HA40EUIST
Fitting Elbows; Down F3HA20EDIST Fitting Elbows; Down F3HA40EDIST
Accessories End Cable Tap Box (Up) F3HA20TTIST Accessories End Cable Tap Box (Up) F3HA40TTIST
Accessories End Cable Tap Box (Dn) F3HA20TBIST Accessories End Cable Tap Box (Dn) F3HA40TBIST
Accessories Center Cable Tap Box (Up) F3HA20CTIST Accessories Center Cable Tap Box (Up) F3HA40CTIST
Accessories Center Cable Tap Box (Dn) F3HA20CBIST Accessories Center Cable Tap Box (Dn) F3HA40CBIST
Accessories End Box F3HA20EBIST Accessories End Box F3HA40EBIST
Accessories Flanged End w/ Lugs F3HA20FLIST Accessories Flanged End w/ Lugs F3HA40FLIST
Accessories Flanged End F3HA20FEIST Accessories Flanged End F3HA40FEIST

2500 Amps Three-Phase, Three-Wire


Integrated Housing Ground
Component Type Product Number
Linear Lengths 10-ft. plug-in P3HA25SLI10
Linear Lengths 10-ft. feeder F3HA25SLI10
Linear Lengths 10-ft. riser R3HA25SLI10
Fitting Elbows; Left F3HA25ELIST
Fitting Elbows; Right F3HA25ERIST
Fitting Elbows; Up F3HA25EUIST
Fitting Elbows; Down F3HA25EDIST
Accessories End Cable Tap Box (Up) F3HA25TTIST
Accessories End Cable Tap Box (Dn) F3HA25TBIST
Accessories Center Cable Tap Box (Up) F3HA25CTIST
Accessories Center Cable Tap Box (Dn) F3HA25CBIST
Accessories End Box F3HA25EBIST
Accessories Flanged End w/ Lugs F3HA25FLIST
Accessories Flanged End F3HA25FEIST

Aluminum, Three-Wire, Housing Ground

Rev. 11/13 www.geindustrial.com BuyLog Catalog 13-9


Data subject to change
without notice
Busway Section 13
Spectra Series Busway (continued)
Sandwich Bus
Aluminum Conductors

225 Amps Three-Phase, Four-Wire 800 Amps Three-Phase, Four-Wire


Integrated Housing Ground Integrated Housing Ground
Component Type Product Number Component Type Product Number
Linear Lengths 10-ft. plug-in P4HA02SLI10 Linear Lengths 10-ft. plug-in P4HA08SLI10
Linear Lengths 10-ft. feeder F4HA02SLI10 Linear Lengths 10-ft. feeder F4HA08SLI10
Linear Lengths 10-ft. riser R4HA02SLI10 Linear Lengths 10-ft. riser R4HA08SLI10
Fitting Elbows; Left F4HA02ELIST Fitting Elbows; Left F4HA08ELIST
Fitting Elbows; Right F4HA02ERIST Fitting Elbows; Right F4HA08ERIST
Fitting Elbows; Up F4HA02EUIST Fitting Elbows; Up F4HA08EUIST
Fitting Elbows; Down F4HA02EDIST Fitting Elbows; Down F4HA08EDIST
Accessories End Cable Tap Box (Up) F4HA02TTIST Accessories End Cable Tap Box (Up) F4HA08TTIST
Accessories End Cable Tap Box (Dn) F4HA02TBIST Accessories End Cable Tap Box (Dn) F4HA08TBIST
Accessories Center Cable Tap Box (Up) F4HA02CTIST Accessories Center Cable Tap Box (Up) F4HA08CTIST
Accessories Center Cable Tap Box (Dn) F4HA02CBIST Accessories Center Cable Tap Box (Dn) F4HA08CBIST
Accessories End Box F4HA02EBIST Accessories End Box F4HA08EBIST
Accessories Flanged End w/ Lugs F4HA02FLIST Accessories Flanged End w/ Lugs F4HA08FLIST
Accessories Flanged End F4HA02FEIST Accessories Flanged End F4HA08FEIST

400 Amps Three-Phase, Four-Wire 1000 Amps Three-Phase, Four-Wire


Integrated Housing Ground Integrated Housing Ground
Component Type Product Number Component Type Product Number
Linear Lengths 10-ft. plug-in P4HA04SLI10 Linear Lengths 10-ft. plug-in P4HA10SLI10
Linear Lengths 10-ft. feeder F4HA04SLI10 Linear Lengths 10-ft. feeder F4HA10SLI10
Linear Lengths 10-ft. riser R4HA04SLI10 Linear Lengths 10-ft. riser R4HA10SLI10
Fitting Elbows; Left F4HA04ELIST Fitting Elbows; Left F4HA10ELIST
Fitting Elbows; Right F4HA04ERIST Fitting Elbows; Right F4HA10ERIST
Fitting Elbows; Up F4HA04EUIST Fitting Elbows; Up F4HA10EUIST
Fitting Elbows; Down F4HA04EDIST Fitting Elbows; Down F4HA10EDIST
Accessories End Cable Tap Box (Up) F4HA04TTIST Accessories End Cable Tap Box (Up) F4HA10TTIST
Accessories End Cable Tap Box (Dn) F4HA04TBIST Accessories End Cable Tap Box (Dn) F4HA10TBIST
Accessories Center Cable Tap Box (Up) F4HA04CTIST Accessories Center Cable Tap Box (Up) F4HA10CTIST
Accessories Center Cable Tap Box (Dn) F4HA04CBIST Accessories Center Cable Tap Box (Dn) F4HA10CBIST
Accessories End Box F4HA04EBIST Accessories End Box F4HA10EBIST
Accessories Flanged End w/ Lugs F4HA04FLIST Accessories Flanged End w/ Lugs F4HA10FLIST
Accessories Flanged End F4HA04FEIST Accessories Flanged End F4HA10FEIST

600 Amps Three-Phase, Four-Wire 1200 Amps Three-Phase, Four-Wire


Integrated Housing Ground Integrated Housing Ground
Component Type Product Number Component Type Product Number
Linear Lengths 10-ft. plug-in P4HA06SLI10 Linear Lengths 10-ft. plug-in P4HA12SLI10
Linear Lengths 10-ft. feeder F4HA06SLI10 Linear Lengths 10-ft. feeder F4HA12SLI10
Linear Lengths 10-ft. riser R4HA06SLI10 Linear Lengths 10-ft. riser R4HA12SLI10
Fitting Elbows; Left F4HA06ELIST Fitting Elbows; Left F4HA12ELIST
Fitting Elbows; Right F4HA06ERIST Fitting Elbows; Right F4HA12ERIST
Fitting Elbows; Up F4HA06EUIST Fitting Elbows; Up F4HA12EUIST
Fitting Elbows; Down F4HA06EDIST Fitting Elbows; Down F4HA12EDIST
Accessories End Cable Tap Box (Up) F4HA06TTIST Accessories End Cable Tap Box (Up) F4HA12TTIST
Accessories End Cable Tap Box (Dn) F4HA06TBIST Accessories End Cable Tap Box (Dn) F4HA12TBIST
Accessories Center Cable Tap Box (Up) F4HA06CTIST Accessories Center Cable Tap Box (Up) F4HA12CTIST
Accessories Center Cable Tap Box (Dn) F4HA06CBIST Accessories Center Cable Tap Box (Dn) F4HA12CBIST
Accessories End Box F4HA06EBIST Accessories End Box F4HA12EBIST
Accessories Flanged End w/ Lugs F4HA06FLIST Accessories Flanged End w/ Lugs F4HA12FLIST
Accessories Flanged End F4HA06FEIST Accessories Flanged End F4HA12FEIST

Aluminum, Four-Wire, Housing Ground

13-10 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Busway Section 13
Spectra Series Busway (continued)
Sandwich Bus
Aluminum Conductors

1600 Amps Three-Phase, Four-Wire 3000 Amps Three-Phase, Four-Wire


Integrated Housing Ground Integrated Housing Ground
Type Product Number Component Type Product Number
Linear Lengths 10-ft. plug-in P4HA16SLI10 Linear Lengths 10-ft. plug-in P4HA30SLI10
Linear Lengths 10-ft. feeder F4HA16SLI10 Linear Lengths 10-ft. feeder F4HA30SLI10
Linear Lengths 10-ft. riser R4HA16SLI10 Linear Lengths 10-ft. riser R4HA30SLI10
Fitting Elbows; Left F4HA16ELIST Fitting Elbows; Left F4HA30ELIST
Fitting Elbows; Right F4HA16ERIST Fitting Elbows; Right F4HA30ERIST
Fitting Elbows; Up F4HA16EUIST Fitting Elbows; Up F4HA30EUIST
Fitting Elbows; Down F4HA16EDIST Fitting Elbows; Down F4HA30EDIST
Accessories End Cable Tap Box (Up) F4HA16TTIST Accessories End Cable Tap Box (Up) F4HA30TTIST
Accessories End Cable Tap Box (Dn) F4HA16TBIST Accessories End Cable Tap Box (Dn) F4HA30TBIST
Accessories Center Cable Tap Box (Up) F4HA16CTIST Accessories Center Cable Tap Box (Up) F4HA30CTIST
Accessories Center Cable Tap Box (Dn) F4HA16CBIST Accessories Center Cable Tap Box (Dn) F4HA30CBIST
Accessories End Box F4HA16EBIST Accessories End Box F4HA30EBIST
Accessories Flanged End w/ Lugs F4HA16FLIST Accessories Flanged End w/ Lugs F4HA30FLIST
Accessories Flanged End F4HA16FEIST Accessories Flanged End F4HA30FEIST

2000 Amps Three-Phase, Four-Wire 4000 Amps Three-Phase, Four-Wire


Integrated Housing Ground Integrated Housing Ground
Component Type Product Number Component Type Product Number
Linear Lengths 10-ft. plug-in P4HA20SLI10 Linear Lengths 10-ft. plug-in P4HA40SLI10
Linear Lengths 10-ft. feeder F4HA20SLI10 Linear Lengths 10-ft. feeder F4HA40SLI10
Linear Lengths 10-ft. riser R4HA20SLI10 Linear Lengths 10-ft. riser R4HA40SLI10
Fitting Elbows; Left F4HA20ELIST Fitting Elbows; Left F4HA40ELIST
Fitting Elbows; Right F4HA20ERIST Fitting Elbows; Right F4HA40ERIST
Fitting Elbows; Up F4HA20EUIST Fitting Elbows; Up F4HA40EUIST
Fitting Elbows; Down F4HA20EDIST Fitting Elbows; Down F4HA40EDIST
Accessories End Cable Tap Box (Up) F4HA20TTIST Accessories End Cable Tap Box (Up) F4HA40TTIST
Accessories End Cable Tap Box (Dn) F4HA20TBIST Accessories End Cable Tap Box (Dn) F4HA40TBIST
Accessories Center Cable Tap Box (Up) F4HA20CTIST Accessories Center Cable Tap Box (Up) F4HA40CTIST
Accessories Center Cable Tap Box (Dn) F4HA20CBIST Accessories Center Cable Tap Box (Dn) F4HA40CBIST
Accessories End Box F4HA20EBIST Accessories End Box F4HA40EBIST
Accessories Flanged End w/ Lugs F4HA20FLIST Accessories Flanged End w/ Lugs F4HA40FLIST
Accessories Flanged End F4HA20FEIST Accessories Flanged End F4HA40FEIST

2500 Amps Three-Phase, Four-Wire Hangers -


Integrated Housing Ground Common to all Services
Component Type Product Number Component Type Product Number
Linear Lengths 10-ft. plug-in P4HA25SLI10 225-600 Amps Flatwise (st.) SBF16
Linear Lengths 10-ft. feeder F4HA25SLI10 800 Amps Flatwise (st.) SBF28
Linear Lengths 10-ft. riser R4HA25SLI10 1000 Amps Flatwise (st.) SBF33
Fitting Elbows; Left F4HA25ELIST 1200 Amps Flatwise (st.) SBF42
Fitting Elbows; Right F4HA25ERIST 1600 Amps Flatwise (st.) SBF65
Fitting Elbows; Up F4HA25EUIST 2000 Amps Flatwise (st.) SBF82
Fitting Elbows; Down F4HA25EDIST 2500 Amps Flatwise (st.) SBF45
Accessories End Cable Tap Box (Up) F4HA25TTIST 3000 Amps Flatwise (st.) SBF57
Accessories End Cable Tap Box (Dn) F4HA25TBIST 4000 Amps Flatwise (st.) SBF82
Accessories Center Cable Tap Box (Up) F4HA25CTIST Up to 2000 Amps Edgewise (st.) SBE45
Accessories Center Cable Tap Box (Dn) F4HA25CBIST 2500A and above Edgewise (st.) SBTE
Accessories End Box F4HA25EBIST Spring SBR1
Accessories Flanged End w/ Lugs F4HA25FLIST
Accessories Flanged End F4HA25FEIST

Aluminum, Four-Wire, Housing Ground

Rev. 11/13 www.geindustrial.com BuyLog Catalog 13-11


Data subject to change
without notice
Busway Section 13
Spectra Series Busway
Sandwich Bus
Copper Conductors

225 Amps Three-Phase, Three-Wire 800 Amps Three-Phase, Three-Wire


Integrated Housing Ground Integrated Housing Ground
Component Type Product Number Component Type Product Number
Linear Lengths 10-ft. plug-in P3HC02SLI10 Linear Lengths 10-ft. plug-in P3HC08SLI10
Linear Lengths 10-ft. feeder F3HC02SLI10 Linear Lengths 10-ft. feeder F3HC08SLI10
Linear Lengths 10-ft. riser R3HC02SLI10 Linear Lengths 10-ft. riser R3HC08SLI10
Fitting Elbows; Left F3HC02ELIST Fitting Elbows; Left F3HC08ELIST
Fitting Elbows; Right F3HC02ERIST Fitting Elbows; Right F3HC08ERIST
Fitting Elbows; Up F3HC02EUIST Fitting Elbows; Up F3HC08EUIST
Fitting Elbows; Down F3HC02EDIST Fitting Elbows; Down F3HC08EDIST
Accessories End Cable Tap Box (Up) F3HC02TTIST Accessories End Cable Tap Box (Up) F3HC08TTIST
Accessories End Cable Tap Box (Dn) F3HC02TBIST Accessories End Cable Tap Box (Dn) F3HC08TBIST
Accessories Center Cable Tap Box (Up) F3HC02CTIST Accessories Center Cable Tap Box (Up) F3HC08CTIST
Accessories Center Cable Tap Box (Dn) F3HC02CBIST Accessories Center Cable Tap Box (Dn) F3HC08CBIST
Accessories End Box F3HC02EBIST Accessories End Box F3HC08EBIST
Accessories Flanged End w/ Lugs F3HC02FLIST Accessories Flanged End w/ Lugs F3HC08FLIST
Accessories Flanged End F3HC02FEIST Accessories Flanged End F3HC08FEIST

400 Amps Three-Phase, Three-Wire 1000 Amps Three-Phase, Three-Wire


Integrated Housing Ground Integrated Housing Ground
Component Type Product Number Component Type Product Number
Linear Lengths 10-ft. plug-in P3HC04SLI10 Linear Lengths 10-ft. plug-in P3HC10SLI10
Linear Lengths 10-ft. feeder F3HC04SLI10 Linear Lengths 10-ft. feeder F3HC10SLI10
Linear Lengths 10-ft. riser R3HC04SLI10 Linear Lengths 10-ft. riser R3HC10SLI10
Fitting Elbows; Left F3HC04ELIST Fitting Elbows; Left F3HC10ELIST
Fitting Elbows; Right F3HC04ERIST Fitting Elbows; Right F3HC10ERIST
Fitting Elbows; Up F3HC04EUIST Fitting Elbows; Up F3HC10EUIST
Fitting Elbows; Down F3HC04EDIST Fitting Elbows; Down F3HC10EDIST
Accessories End Cable Tap Box (Up) F3HC04TTIST Accessories End Cable Tap Box (Up) F3HC10TTIST
Accessories End Cable Tap Box (Dn) F3HC04TBIST Accessories End Cable Tap Box (Dn) F3HC10TBIST
Accessories Center Cable Tap Box (Up) F3HC04CTIST Accessories Center Cable Tap Box (Up) F3HC10CTIST
Accessories Center Cable Tap Box (Dn) F3HC04CBIST Accessories Center Cable Tap Box (Dn) F3HC10CBIST
Accessories End Box F3HC04EBIST Accessories End Box F3HC10EBIST
Accessories Flanged End w/ Lugs F3HC04FLIST Accessories Flanged End w/ Lugs F3HC10FLIST
Accessories Flanged End F3HC04FEIST Accessories Flanged End F3HC10FEIST

600 Amps Three-Phase, Three-Wire 1200 Amps Three-Phase, Three-Wire


Integrated Housing Ground Integrated Housing Ground
Component Type Product Number Component Type Product Number
Linear Lengths 10-ft. plug-in P3HC06SLI10 Linear Lengths 10-ft. plug-in P3HC12SLI10
Linear Lengths 10-ft. feeder F3HC06SLI10 Linear Lengths 10-ft. feeder F3HC12SLI10
Linear Lengths 10-ft. riser R3HC06SLI10 Linear Lengths 10-ft. riser R3HC12SLI10
Fitting Elbows; Left F3HC06ELIST Fitting Elbows; Left F3HC12ELIST
Fitting Elbows; Right F3HC06ERIST Fitting Elbows; Right F3HC12ERIST
Fitting Elbows; Up F3HC06EUIST Fitting Elbows; Up F3HC12EUIST
Fitting Elbows; Down F3HC06EDIST Fitting Elbows; Down F3HC12EDIST
Accessories End Cable Tap Box (Up) F3HC06TTIST Accessories End Cable Tap Box (Up) F3HC12TTIST
Accessories End Cable Tap Box (Dn) F3HC06TBIST Accessories End Cable Tap Box (Dn) F3HC12TBIST
Accessories Center Cable Tap Box (Up) F3HC06CTIST Accessories Center Cable Tap Box (Up) F3HC12CTIST
Accessories Center Cable Tap Box (Dn) F3HC06CBIST Accessories Center Cable Tap Box (Dn) F3HC12CBIST
Accessories End Box F3HC06EBIST Accessories End Box F3HC12EBIST
Accessories Flanged End w/ Lugs F3HC06FLIST Accessories Flanged End w/ Lugs F3HC12FLIST
Accessories Flanged End F3HC06FEIST Accessories Flanged End F3HC12FEIST

Copper, Three-Wire, Housing Ground

13-12 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Busway Section 13
Spectra Series Busway (continued)
Sandwich Bus
Copper Conductors

1600 Amps Three-Phase, Three-Wire 3000 Amps Three-Phase, Three-Wire


Integrated Housing Ground Integrated Housing Ground
Component Type Product Number Component Type Product Number
Linear Lengths 10-ft. plug-in P3HC16SLI10 Linear Lengths 10-ft. plug-in P3HC30SLI10
Linear Lengths 10-ft. feeder F3HC16SLI10 Linear Lengths 10-ft. feeder F3HC30SLI10
Linear Lengths 10-ft. riser R3HC16SLI10 Linear Lengths 10-ft. riser R3HC30SLI10
Fitting Elbows; Left F3HC16ELIST Fitting Elbows; Left F3HC30ELIST
Fitting Elbows; Right F3HC16ERIST Fitting Elbows; Right F3HC30ERIST
Fitting Elbows; Up F3HC16EUIST Fitting Elbows; Up F3HC30EUIST
Fitting Elbows; Down F3HC16EDIST Fitting Elbows; Down F3HC30EDIST
Accessories End Cable Tap Box (Up) F3HC16TTIST Accessories End Cable Tap Box (Up) F3HC30TTIST
Accessories End Cable Tap Box (Dn) F3HC16TBIST Accessories End Cable Tap Box (Dn) F3HC30TBIST
Accessories Center Cable Tap Box (Up) F3HC16CTIST Accessories Center Cable Tap Box (Up) F3HC30CTIST
Accessories Center Cable Tap Box (Dn) F3HC16CBIST Accessories Center Cable Tap Box (Dn) F3HC30CBIST
Accessories End Box F3HC16EBIST Accessories End Box F3HC30EBIST
Accessories Flanged End w/ Lugs F3HC16FLIST Accessories Flanged End w/ Lugs F3HC30FLIST
Accessories Flanged End F3HC16FEIST Accessories Flanged End F3HC30FEIST

2000 Amps Three-Phase, Three-Wire 4000 Amps Three-Phase, Three-Wire


Integrated Housing Ground Integrated Housing Ground
Component Type Product Number Component Type Product Number
Linear Lengths 10-ft. plug-in P3HC20SLI10 Linear Lengths 10-ft. plug-in P3HC40SLI10
Linear Lengths 10-ft. feeder F3HC20SLI10 Linear Lengths 10-ft. feeder F3HC40SLI10
Linear Lengths 10-ft. riser R3HC20SLI10 Linear Lengths 10-ft. riser R3HC40SLI10
Fitting Elbows; Left F3HC20ELIST Fitting Elbows; Left F3HC40ELIST
Fitting Elbows; Right F3HC20ERIST Fitting Elbows; Right F3HC40ERIST
Fitting Elbows; Up F3HC20EUIST Fitting Elbows; Up F3HC40EUIST
Fitting Elbows; Down F3HC20EDIST Fitting Elbows; Down F3HC40EDIST
Accessories End Cable Tap Box (Up) F3HC20TTIST Accessories End Cable Tap Box (Up) F3HC40TTIST
Accessories End Cable Tap Box (Dn) F3HC20TBIST Accessories End Cable Tap Box (Dn) F3HC40TBIST
Accessories Center Cable Tap Box (Up) F3HC20CTIST Accessories Center Cable Tap Box (Up) F3HC40CTIST
Accessories Center Cable Tap Box (Dn) F3HC20CBIST Accessories Center Cable Tap Box (Dn) F3HC40CBIST
Accessories End Box F3HC20EBIST Accessories End Box F3HC40EBIST
Accessories Flanged End w/ Lugs F3HC20FLIST Accessories Flanged End w/ Lugs F3HC40FLIST
Accessories Flanged End F3HC20FEIST Accessories Flanged End F3HC40FEIST

2500 Amps Three-Phase, Three-Wire


Integrated Housing Ground
Component Type Product Number
Linear Lengths 10-ft. plug-in P3HC25SLI10
Linear Lengths 10-ft. feeder F3HC25SLI10
Linear Lengths 10-ft. riser R3HC25SLI10
Fitting Elbows; Left F3HC25ELIST
Fitting Elbows; Right F3HC25ERIST
Fitting Elbows; Up F3HC25EUIST
Fitting Elbows; Down F3HC25EDIST
Accessories End Cable Tap Box (Up) F3HC25TTIST
Accessories End Cable Tap Box (Dn) F3HC25TBIST
Accessories Center Cable Tap Box (Up) F3HC25CTIST
Accessories Center Cable Tap Box (Dn) F3HC25CBIST
Accessories End Box F3HC25EBIST
Accessories Flanged End w/ Lugs F3HC25FLIST
Accessories Flanged End F3HC25FEIST

Copper, Three-Wire, Housing Ground

Rev. 11/13 www.geindustrial.com BuyLog Catalog 13-13


Data subject to change
without notice
Busway Section 13
Spectra Series Busway (continued)
Sandwich Bus
Copper Conductors

225 Amps Three-Phase, Four-Wire 800 Amps Three-Phase, Four-Wire


Integrated Housing Ground Integrated Housing Ground
Component Type Product Number Component Type Product Number
Linear Lengths 10-ft. plug-in P4HC02SLI10 Linear Lengths 10-ft. plug-in P4HC08SLI10
Linear Lengths 10-ft. feeder F4HC02SLI10 Linear Lengths 10-ft. feeder F4HC08SLI10
Linear Lengths 10-ft. riser R4HC02SLI10 Linear Lengths 10-ft. riser R4HC08SLI10
Fitting Elbows; Left F4HC02ELIST Fitting Elbows; Left F4HC08ELIST
Fitting Elbows; Right F4HC02ERIST Fitting Elbows; Right F4HC08ERIST
Fitting Elbows; Up F4HC02EUIST Fitting Elbows; Up F4HC08EUIST
Fitting Elbows; Down F4HC02EDIST Fitting Elbows; Down F4HC08EDIST
Accessories End Cable Tap Box (Up) F4HC02TTIST Accessories End Cable Tap Box (Up) F4HC08TTIST
Accessories End Cable Tap Box (Dn) F4HC02TBIST Accessories End Cable Tap Box (Dn) F4HC08TBIST
Accessories Center Cable Tap Box (Up) F4HC02CTIST Accessories Center Cable Tap Box (Up) F4HC08CTIST
Accessories Center Cable Tap Box (Dn) F4HC02CBIST Accessories Center Cable Tap Box (Dn) F4HC08CBIST
Accessories End Box F4HC02EBIST Accessories End Box F4HC08EBIST
Accessories Flanged End w/ Lugs F4HC02FLIST Accessories Flanged End w/ Lugs F4HC08FLIST
Accessories Flanged End F4HC02FEIST Accessories Flanged End F4HC08FEIST

400 Amps Three-Phase, Four-Wire 1000 Amps Three-Phase, Four-Wire


Integrated Housing Ground Integrated Housing Ground
Component Type Product Number Component Type Product Number
Linear Lengths 10-ft. plug-in P4HC04SLI10 Linear Lengths 10-ft. plug-in P4HC10SLI10
Linear Lengths 10-ft. feeder F4HC04SLI10 Linear Lengths 10-ft. feeder F4HC10SLI10
Linear Lengths 10-ft. riser R4HC04SLI10 Linear Lengths 10-ft. riser R4HC10SLI10
Fitting Elbows; Left F4HC04ELIST Fitting Elbows; Left F4HC10ELIST
Fitting Elbows; Right F4HC04ERIST Fitting Elbows; Right F4HC10ERIST
Fitting Elbows; Up F4HC04EUIST Fitting Elbows; Up F4HC10EUIST
Fitting Elbows; Down F4HC04EDIST Fitting Elbows; Down F4HC10EDIST
Accessories End Cable Tap Box (Up) F4HC04TTIST Accessories End Cable Tap Box (Up) F4HC10TTIST
Accessories End Cable Tap Box (Dn) F4HC04TBIST Accessories End Cable Tap Box (Dn) F4HC10TBIST
Accessories Center Cable Tap Box (Up) F4HC04CTIST Accessories Center Cable Tap Box (Up) F4HC10CTIST
Accessories Center Cable Tap Box (Dn) F4HC04CBIST Accessories Center Cable Tap Box (Dn) F4HC10CBIST
Accessories End Box F4HC04EBIST Accessories End Box F4HC10EBIST
Accessories Flanged End w/ Lugs F4HC04FLIST Accessories Flanged End w/ Lugs F4HC10FLIST
Accessories Flanged End F4HC04FEIST Accessories Flanged End F4HC10FEIST

600 Amps Three-Phase, Four-Wire 1200 Amps Three-Phase, Four-Wire


Integrated Housing Ground Integrated Housing Ground
Component Type Product Number Component Type Product Number
Linear Lengths 10-ft. plug-in P4HC06SLI10 Linear Lengths 10-ft. plug-in P4HC12SLI10
Linear Lengths 10-ft. feeder F4HC06SLI10 Linear Lengths 10-ft. feeder F4HC12SLI10
Linear Lengths 10-ft. riser R4HC06SLI10 Linear Lengths 10-ft. riser R4HC12SLI10
Fitting Elbows; Left F4HC06ELIST Fitting Elbows; Left F4HC12ELIST
Fitting Elbows; Right F4HC06ERIST Fitting Elbows; Right F4HC12ERIST
Fitting Elbows; Up F4HC06EUIST Fitting Elbows; Up F4HC12EUIST
Fitting Elbows; Down F4HC06EDIST Fitting Elbows; Down F4HC12EDIST
Accessories End Cable Tap Box (Up) F4HC06TTIST Accessories End Cable Tap Box (Up) F4HC12TTIST
Accessories End Cable Tap Box (Dn) F4HC06TBIST Accessories End Cable Tap Box (Dn) F4HC12TBIST
Accessories Center Cable Tap Box (Up) F4HC06CTIST Accessories Center Cable Tap Box (Up) F4HC12CTIST
Accessories Center Cable Tap Box (Dn) F4HC06CBIST Accessories Center Cable Tap Box (Dn) F4HC12CBIST
Accessories End Box F4HC06EBIST Accessories End Box F4HC12EBIST
Accessories Flanged End w/ Lugs F4HC06FLIST Accessories Flanged End w/ Lugs F4HC12FLIST
Accessories Flanged End F4HC06FEIST Accessories Flanged End F4HC12FEIST

Copper, Four-Wire, Housing Ground

13-14 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Busway Section 13
Spectra Series Busway (continued)
Sandwich Bus
Copper Conductors

1600 Amps Three-Phase, Four-Wire 3000 Amps Three-Phase, Four-Wire


Integrated Housing Ground Integrated Housing Ground
Component Type Product Number Component Type Product Number
Linear Lengths 10-ft. plug-in P4HC16SLI10 Linear Lengths 10-ft. plug-in P4HC30SLI10
Linear Lengths 10-ft. feeder F4HC16SLI10 Linear Lengths 10-ft. feeder F4HC30SLI10
Linear Lengths 10-ft. riser R4HC16SLI10 Linear Lengths 10-ft. riser R4HC30SLI10
Fitting Elbows; Left F4HC16ELIST Fitting Elbows; Left F4HC30ELIST
Fitting Elbows; Right F4HC16ERIST Fitting Elbows; Right F4HC30ERIST
Fitting Elbows; Up F4HC16EUIST Fitting Elbows; Up F4HC30EUIST
Fitting Elbows; Down F4HC16EDIST Fitting Elbows; Down F4HC30EDIST
Accessories End Cable Tap Box (Up) F4HC16TTIST Accessories End Cable Tap Box (Up) F4HC30TTIST
Accessories End Cable Tap Box (Dn) F4HC16TBIST Accessories End Cable Tap Box (Dn) F4HC30TBIST
Accessories Center Cable Tap Box (Up) F4HC16CTIST Accessories Center Cable Tap Box (Up) F4HC30CTIST
Accessories Center Cable Tap Box (Dn) F4HC16CBIST Accessories Center Cable Tap Box (Dn) F4HC30CBIST
Accessories End Box F4HC16EBIST Accessories End Box F4HC30EBIST
Accessories Flanged End w/ Lugs F4HC16FLIST Accessories Flanged End w/ Lugs F4HC30FLIST
Accessories Flanged End F4HC16FEIST Accessories Flanged End F4HC30FEIST

2000 Amps Three-Phase, Four-Wire 4000 Amps Three-Phase, Four-Wire


Integrated Housing Ground Integrated Housing Ground
Component Type Product Number Component Type Product Number
Linear Lengths 10-ft. plug-in P4HC20SLI10 Linear Lengths 10-ft. plug-in P4HC40SLI10
Linear Lengths 10-ft. feeder F4HC20SLI10 Linear Lengths 10-ft. feeder F4HC40SLI10
Linear Lengths 10-ft. riser R4HC20SLI10 Linear Lengths 10-ft. riser R4HC40SLI10
Fitting Elbows; Left F4HC20ELIST Fitting Elbows; Left F4HC40ELIST
Fitting Elbows; Right F4HC20ERIST Fitting Elbows; Right F4HC40ERIST
Fitting Elbows; Up F4HC20EUIST Fitting Elbows; Up F4HC40EUIST
Fitting Elbows; Down F4HC20EDIST Fitting Elbows; Down F4HC40EDIST
Accessories End Cable Tap Box (Up) F4HC20TTIST Accessories End Cable Tap Box (Up) F4HC40TTIST
Accessories End Cable Tap Box (Dn) F4HC20TBIST Accessories End Cable Tap Box (Dn) F4HC40TBIST
Accessories Center Cable Tap Box (Up) F4HC20CTIST Accessories Center Cable Tap Box (Up) F4HC40CTIST
Accessories Center Cable Tap Box (Dn) F4HC20CBIST Accessories Center Cable Tap Box (Dn) F4HC40CBIST
Accessories End Box F4HC20EBIST Accessories End Box F4HC40EBIST
Accessories Flanged End w/ Lugs F4HC20FLIST Accessories Flanged End w/ Lugs F4HC40FLIST
Accessories Flanged End F4HC20FEIST Accessories Flanged End F4HC40FEIST

2500 Amps Three-Phase, Four-Wire Hangers -


Integrated Housing Ground Common to All Services
Component Type Product Number Component Type Product Number
Linear Lengths 10-ft. plug-in P4HC25SLI10 225-800 Amps Flatwise (st.) SBF16
Linear Lengths 10-ft. feeder F4HC25SLI10 1000 Amps Flatwise (st.) SBF22
Linear Lengths 10-ft. riser R4HC25SLI10 1200 Amps Flatwise (st.) SBF28
Fitting Elbows; Left F4HC25ELIST 1600 Amps Flatwise (st.) SBF42
Fitting Elbows; Right F4HC25ERIST 2000 Amps Flatwise (st.) SBTF
Fitting Elbows; Up F4HC25EUIST 2500 Amps Flatwise (st.) SBTF
Fitting Elbows; Down F4HC25EDIST 3000 Amps Flatwise (st.) SBTG
Accessories End Cable Tap Box (Up) F4HC25TTIST 225-1600 Amps Edgewise (st.) SBTH
Accessories End Cable Tap Box (Dn) F4HC25TBIST 2000A and above Edgewise (st.) SBTE
Accessories Center Cable Tap Box (Up) F4HC25CTIST 1200 Amps Spring SBR1
Accessories Center Cable Tap Box (Dn) F4HC25CBIST 4000 Amps Spring SBR2
Accessories End Box F4HC25EBIST
Accessories Flanged End w/ Lugs F4HC25FLIST
Accessories Flanged End F4HC25FEIST

Copper, Four-Wire, Housing Ground

Rev. 11/13 www.geindustrial.com BuyLog Catalog 13-15


Data subject to change
without notice
Busway Section 13
Spectra Series Busway
Sandwich Bus
Copper Conductors

225 Amps Three-Phase, Three-Wire Internal Ground Bar 800 Amps Three-Phase, Three-Wire Internal Ground Bar
Component Type Product Number Component Type Product Number
Linear Lengths 10-ft. plug-in P3GC02SLI10 Linear Lengths 10-ft. plug-in P3GC08SLI10
Linear Lengths 10-ft. feeder F3GC02SLI10 Linear Lengths 10-ft. feeder F3GC08SLI10
Linear Lengths 10-ft. riser R3GC02SLI10 Linear Lengths 10-ft. riser R3GC08SLI10
Fitting Elbows; Left F3GC02ELIST Fitting Elbows; Left F3GC08ELIST
Fitting Elbows; Right F3GC02ERIST Fitting Elbows; Right F3GC08ERIST
Fitting Elbows; Up F3GC02EUIST Fitting Elbows; Up F3GC08EUIST
Fitting Elbows; Down F3GC02EDIST Fitting Elbows; Down F3GC08EDIST
Accessories End Cable Tap Box (Up) F3GC02TTIST Accessories End Cable Tap Box (Up) F3GC08TTIST
Accessories End Cable Tap Box (Dn) F3GC02TBIST Accessories End Cable Tap Box (Dn) F3GC08TBIST
Accessories Center Cable Tap Box (Up) F3GC02CTIST Accessories Center Cable Tap Box (Up) F3GC08CTIST
Accessories Center Cable Tap Box (Dn) F3GC02CBIST Accessories Center Cable Tap Box (Dn) F3GC08CBIST
Accessories End Box F3GC02EBIST Accessories End Box F3GC08EBIST
Accessories Flanged End w/ Lugs F3GC02FLIST Accessories Flanged End w/ Lugs F3GC08FLIST
Accessories Flanged End F3GC02FEIST Accessories Flanged End F3GC08FEIST

400 Amps Three-Phase, Three-Wire Internal Ground Bar 1000 Amps Three-Phase, Three-Wire Internal Ground Bar
Component Type Product Number Component Type Product Number
Linear Lengths 10-ft. plug-in P3GC04SLI10 Linear Lengths 10-ft. plug-in P3GC10SLI10
Linear Lengths 10-ft. feeder F3GC04SLI10 Linear Lengths 10-ft. feeder F3GC10SLI10
Linear Lengths 10-ft. riser R3GC04SLI10 Linear Lengths 10-ft. riser R3GC10SLI10
Fitting Elbows; Left F3GC04ELIST Fitting Elbows; Left F3GC10ELIST
Fitting Elbows; Right F3GC04ERIST Fitting Elbows; Right F3GC10ERIST
Fitting Elbows; Up F3GC04EUIST Fitting Elbows; Up F3GC10EUIST
Fitting Elbows; Down F3GC04EDIST Fitting Elbows; Down F3GC10EDIST
Accessories End Cable Tap Box (Up) F3GC04TTIST Accessories End Cable Tap Box (Up) F3GC10TTIST
Accessories End Cable Tap Box (Dn) F3GC04TBIST Accessories End Cable Tap Box (Dn) F3GC10TBIST
Accessories Center Cable Tap Box (Up) F3GC04CTIST Accessories Center Cable Tap Box (Up) F3GC10CTIST
Accessories Center Cable Tap Box (Dn) F3GC04CBIST Accessories Center Cable Tap Box (Dn) F3GC10CBIST
Accessories End Box F3GC04EBIST Accessories End Box F3GC10EBIST
Accessories Flanged End w/ Lugs F3GC04FLIST Accessories Flanged End w/ Lugs F3GC10FLIST
Accessories Flanged End F3GC04FEIST Accessories Flanged End F3GC10FEIST

600 Amps Three-Phase, Three-Wire Internal Ground Bar 1200 Amps Three-Phase, Three-Wire Internal Ground Bar
Component Type Product Number Component Type Product Number
Linear Lengths 10-ft. plug-in P3GC06SLI10 Linear Lengths 10-ft. plug-in P3GC12SLI10
Linear Lengths 10-ft. feeder F3GC06SLI10 Linear Lengths 10-ft. feeder F3GC12SLI10
Linear Lengths 10-ft. riser R3GC06SLI10 Linear Lengths 10-ft. riser R3GC12SLI10
Fitting Elbows; Left F3GC06ELIST Fitting Elbows; Left F3GC12ELIST
Fitting Elbows; Right F3GC06ERIST Fitting Elbows; Right F3GC12ERIST
Fitting Elbows; Up F3GC06EUIST Fitting Elbows; Up F3GC12EUIST
Fitting Elbows; Down F3GC06EDIST Fitting Elbows; Down F3GC12EDIST
Accessories End Cable Tap Box (Up) F3GC06TTIST Accessories End Cable Tap Box (Up) F3GC12TTIST
Accessories End Cable Tap Box (Dn) F3GC06TBIST Accessories End Cable Tap Box (Dn) F3GC12TBIST
Accessories Center Cable Tap Box (Up) F3GC06CTIST Accessories Center Cable Tap Box (Up) F3GC12CTIST
Accessories Center Cable Tap Box (Dn) F3GC06CBIST Accessories Center Cable Tap Box (Dn) F3GC12CBIST
Accessories End Box F3GC06EBIST Accessories End Box F3GC12EBIST
Accessories Flanged End w/ Lugs F3GC06FLIST Accessories Flanged End w/ Lugs F3GC12FLIST
Accessories Flanged End F3GC06FEIST Accessories Flanged End F3GC12FEIST

Copper, Three-Wire, Internal Ground

13-16 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Busway Section 13
Spectra Series Busway (continued)
Sandwich Bus
Copper Conductors

1600 Amps Three-Phase, Three-Wire Internal Ground Bar 3000 Amps Three-Phase, Three-Wire Internal Ground Bar
Component Type Product Number Component Type Product Number
Linear Lengths 10-ft. plug-in P3GC16SLI10 Linear Lengths 10-ft. plug-in P3GC30SLI10
Linear Lengths 10-ft. feeder F3GC16SLI10 Linear Lengths 10-ft. feeder F3GC30SLI10
Linear Lengths 10-ft. riser R3GC16SLI10 Linear Lengths 10-ft. riser R3GC30SLI10
Fitting Elbows; Left F3GC16ELIST Fitting Elbows; Left F3GC30ELIST
Fitting Elbows; Right F3GC16ERIST Fitting Elbows; Right F3GC30ERIST
Fitting Elbows; Up F3GC16EUIST Fitting Elbows; Up F3GC30EUIST
Fitting Elbows; Down F3GC16EDIST Fitting Elbows; Down F3GC30EDIST
Accessories End Cable Tap Box (Up) F3GC16TTIST Accessories End Cable Tap Box (Up) F3GC30TTIST
Accessories End Cable Tap Box (Dn) F3GC16TBIST Accessories End Cable Tap Box (Dn) F3GC30TBIST
Accessories Center Cable Tap Box (Up) F3GC16CTIST Accessories Center Cable Tap Box (Up) F3GC30CTIST
Accessories Center Cable Tap Box (Dn) F3GC16CBIST Accessories Center Cable Tap Box (Dn) F3GC30CBIST
Accessories End Box F3GC16EBIST Accessories End Box F3GC30EBIST
Accessories Flanged End w/ Lugs F3GC16FLIST Accessories Flanged End w/ Lugs F3GC30FLIST
Accessories Flanged End F3GC16FEIST Accessories Flanged End F3GC30FEIST

2000 Amps Three-Phase, Three-Wire Internal Ground Bar 4000 Amps Three-Phase, Three-Wire Internal Ground Bar
Component Type Product Number Component Type Product Number
Linear Lengths 10-ft. plug-in P3GC20SLI10 Linear Lengths 10-ft. plug-in P3GC40SLI10
Linear Lengths 10-ft. feeder F3GC20SLI10 Linear Lengths 10-ft. feeder F3GC40SLI10
Linear Lengths 10-ft. riser R3GC20SLI10 Linear Lengths 10-ft. riser R3GC40SLI10
Fitting Elbows; Left F3GC20ELIST Fitting Elbows; Left F3GC40ELIST
Fitting Elbows; Right F3GC20ERIST Fitting Elbows; Right F3GC40ERIST
Fitting Elbows; Up F3GC20EUIST Fitting Elbows; Up F3GC40EUIST
Fitting Elbows; Down F3GC20EDIST Fitting Elbows; Down F3GC40EDIST
Accessories End Cable Tap Box (Up) F3GC20TTIST Accessories End Cable Tap Box (Up) F3GC40TTIST
Accessories End Cable Tap Box (Dn) F3GC20TBIST Accessories End Cable Tap Box (Dn) F3GC40TBIST
Accessories Center Cable Tap Box (Up) F3GC20CTIST Accessories Center Cable Tap Box (Up) F3GC40CTIST
Accessories Center Cable Tap Box (Dn) F3GC20CBIST Accessories Center Cable Tap Box (Dn) F3GC40CBIST
Accessories End Box F3GC20EBIST Accessories End Box F3GC40EBIST
Accessories Flanged End w/ Lugs F3GC20FLIST Accessories Flanged End w/ Lugs F3GC40FLIST
Accessories Flanged End F3GC20FEIST Accessories Flanged End F3GC40FEIST

2500 Amps Three-Phase, Three-Wire Internal Ground Bar


Component Type Product Number
Linear Lengths 10-ft. plug-in P3GC25SLI10
Linear Lengths 10-ft. feeder F3GC25SLI10
Linear Lengths 10-ft. riser R3GC25SLI10
Fitting Elbows; Left F3GC25ELIST
Fitting Elbows; Right F3GC25ERIST
Fitting Elbows; Up F3GC25EUIST
Fitting Elbows; Down F3GC25EDIST
Accessories End Cable Tap Box (Up) F3GC25TTIST
Accessories End Cable Tap Box (Dn) F3GC25TBIST
Accessories Center Cable Tap Box (Up) F3GC25CTIST
Accessories Center Cable Tap Box (Dn) F3GC25CBIST
Accessories End Box F3GC25EBIST
Accessories Flanged End w/ Lugs F3GC25FLIST
Accessories Flanged End F3GC25FEIST

Copper, Three-Wire, Internal Ground

Rev. 11/13 www.geindustrial.com BuyLog Catalog 13-17


Data subject to change
without notice
Busway Section 13
Spectra Series Busway (continued)
Sandwich Bus
Copper Conductors

225 Amps Three-Phase, Four-Wire Internal Ground Bar 800 Amps Three-Phase, Four-Wire Internal Ground Bar
Component Type Product Number Component Type Product Number
Linear Lengths 10-ft. plug-in P4GC02SLI10 Linear Lengths 10-ft. plug-in P4GC08SLI10
Linear Lengths 10-ft. feeder F4GC02SLI10 Linear Lengths 10-ft. feeder F4GC08SLI10
Linear Lengths 10-ft. riser R4GC02SLI10 Linear Lengths 10-ft. riser R4GC08SLI10
Fitting Elbows; Left F4GC02ELIST Fitting Elbows; Left F4GC08ELIST
Fitting Elbows; Right F4GC02ERIST Fitting Elbows; Right F4GC08ERIST
Fitting Elbows; Up F4GC02EUIST Fitting Elbows; Up F4GC08EUIST
Fitting Elbows; Down F4GC02EDIST Fitting Elbows; Down F4GC08EDIST
Accessories End Cable Tap Box (Up) F4GC02TTIST Accessories End Cable Tap Box (Up) F4GC08TTIST
Accessories End Cable Tap Box (Dn) F4GC02TBIST Accessories End Cable Tap Box (Dn) F4GC08TBIST
Accessories Center Cable Tap Box (Up) F4GC02CTIST Accessories Center Cable Tap Box (Up) F4GC08CTIST
Accessories Center Cable Tap Box (Dn) F4GC02CBIST Accessories Center Cable Tap Box (Dn) F4GC08CBIST
Accessories End Box F4GC02EBIST Accessories End Box F4GC08EBIST
Accessories Flanged End w/ Lugs F4GC02FLIST Accessories Flanged End w/ Lugs F4GC08FLIST
Accessories Flanged End F4GC02FEIST Accessories Flanged End F4GC08FEIST

400 Amps Three-Phase, Four-Wire Internal Ground Bar 1000 Amps Three-Phase, Four-Wire Internal Ground Bar
Component Type Product Number Component Type Product Number
Linear Lengths 10-ft. plug-in P4GC04SLI10 Linear Lengths 10-ft. plug-in PAGC10SLI10
Linear Lengths 10-ft. feeder F4GC04SLI10 Linear Lengths 10-ft. feeder F4GC10SLI10
Linear Lengths 10-ft. riser R4GC04SLI10 Linear Lengths 10-ft. riser R4GC10SLI10
Fitting Elbows; Left F4GC04ELIST Fitting Elbows; Left F4GC10ELIST
Fitting Elbows; Right F4GC04ERIST Fitting Elbows; Right F4GC10ERIST
Fitting Elbows; Up F4GC04EUIST Fitting Elbows; Up F4GC10EUIST
Fitting Elbows; Down F4GC04EDIST Fitting Elbows; Down F4GC10EDIST
Accessories End Cable Tap Box (Up) F4GC04TTIST Accessories End Cable Tap Box (Up) F4GC10TTIST
Accessories End Cable Tap Box (Dn) F4GC04TBIST Accessories End Cable Tap Box (Dn) F4GC10TBIST
Accessories Center Cable Tap Box (Up) F4GC04CTIST Accessories Center Cable Tap Box (Up) F4GC10CTIST
Accessories Center Cable Tap Box (Dn) F4GC04CBIS Accessories Center Cable Tap Box (Dn) F4GC10CBIST
Accessories End Box F4GC04EBIST Accessories End Box F4GC10EBIST
Accessories Flanged End w/ Lugs F4GC04FLIST Accessories Flanged End w/ Lugs F4GC10FLIST
Accessories Flanged End F4GC04FEIST Accessories Flanged End F4GC10FEIST

600 Amps Three-Phase, Four-Wire Internal Ground Bar 1200 Amps Three-Phase, Four-Wire Internal Ground Bar
Component Type Product Number Component Type Product Number
Linear Lengths 10-ft. plug-in P4GC06SLI10 Linear Lengths 10-ft. plug-in P4GC12SLI10
Linear Lengths 10-ft. feeder F4GC06SLI10 Linear Lengths 10-ft. feeder F4GC12SLI10
Linear Lengths 10-ft. riser R4GC06SLI10 Linear Lengths 10-ft. riser R4GC12SLI10
Fitting Elbows; Left F4GC06ELIST Fitting Elbows; Left F4GC12ELIST
Fitting Elbows; Right F4GC06ERIST Fitting Elbows; Right F4GC12ERIST
Fitting Elbows; Up F4GC06EUIST Fitting Elbows; Up F4GC12EUIST
Fitting Elbows; Down F4GC06EDIST Fitting Elbows; Down F4GC12EDIST
Accessories End Cable Tap Box (Up) F4GC06TTIST Accessories End Cable Tap Box (Up) F4GC12TTIST
Accessories End Cable Tap Box (Dn) F4GC06TBIST Accessories End Cable Tap Box (Dn) F4GC12TBIST
Accessories Center Cable Tap Box (Up) F4GC06CTIST Accessories Center Cable Tap Box (Up) F4GC12CTIST
Accessories Center Cable Tap Box (Dn) F4GC06CBIST Accessories Center Cable Tap Box (Dn) F4GC12CBIST
Accessories End Box F4GC06EBIST Accessories End Box F4GC12EBIST
Accessories Flanged End w/ Lugs F4GC06FLIST Accessories Flanged End w/ Lugs F4GC12FLIST
Accessories Flanged End F4GC06FEIST Accessories Flanged End F4GC12FEIST

Copper, Four-Wire, Internal Ground

13-18 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Busway Section 13
Spectra Series Busway (continued)
Sandwich Bus
Copper Conductors

1600 Amps Three-Phase, Four-Wire Internal Ground Bar 3000 Amps Three-Phase, Four-Wire Internal Ground Bar
Component Type Product Number Component Type Product Number
Linear Lengths 10-ft. plug-in P4GC16SLI10 Linear Lengths 10-ft. plug-in P4GC30SLI10
Linear Lengths 10-ft. feeder F4GC16SLI10 Linear Lengths 10-ft. feeder F4GC30SLI10
Linear Lengths 10-ft. riser R4GC16SLI10 Linear Lengths 10-ft. riser R4GC30SLI10
Fitting Elbows; Left F4GC16ELIST Fitting Elbows; Left F4GC30ELIST
Fitting Elbows; Right F4GC16ERIST Fitting Elbows; Right F4GC30ERIST
Fitting Elbows; Up F4GC16EUIST Fitting Elbows; Up F4GC30EUIST
Fitting Elbows; Down F4GC16EDIST Fitting Elbows; Down F4GC30EDIST
Accessories End Cable Tap Box (Up) F4GC16TTIST Accessories End Cable Tap Box (Up) F4GC30TTIST
Accessories End Cable Tap Box (Dn) F4GC16TBIST Accessories End Cable Tap Box (Dn) F4GC30TBIST
Accessories Center Cable Tap Box (Up) F4GC16CTIST Accessories Center Cable Tap Box (Up) F4GC30CTIST
Accessories Center Cable Tap Box (Dn) F4GC16CBIST Accessories Center Cable Tap Box (Dn) F4GC30CBIST
Accessories End Box F4GC16EBIST Accessories End Box F4GC30EBIST
Accessories Flanged End w/ Lugs F4GC16FLIST Accessories Flanged End w/ Lugs F4GC30FLIST
Accessories Flanged End F4GC16FEIST Accessories Flanged End F4GC30FEIST

2000 Amps Three-Phase, Four-Wire Internal Ground Bar 4000 Amps Three-Phase, Four-Wire Internal Ground Bar
Component Type Product Number Component Type Product Number
Linear Lengths 10-ft. plug-in P4GC20SLI10 Linear Lengths 10-ft. plug-in P4GC40SLI10
Linear Lengths 10-ft. feeder F4GC20SLI10 Linear Lengths 10-ft. feeder F4GC40SLI10
Linear Lengths 10-ft. riser R4GC20SLI10 Linear Lengths 10-ft. riser R4GC40SLI10
Fitting Elbows; Left F4GC20ELIST Fitting Elbows; Left F4GC40ELIST
Fitting Elbows; Right F4GC20ERIST Fitting Elbows; Right F4GC40ERIST
Fitting Elbows; Up F4GC20EUIST Fitting Elbows; Up F4GC40EUIST
Fitting Elbows; Down F4GC20EDIST Fitting Elbows; Down F4GC40EDIST
Accessories End Cable Tap Box (Up) F4GC20TTIST Accessories End Cable Tap Box (Up) F4GC40TTIST
Accessories End Cable Tap Box (Dn) F4GC20TBIST Accessories End Cable Tap Box (Dn) F4GC40TBIST
Accessories Center Cable Tap Box (Up) F4GC20CTIST Accessories Center Cable Tap Box (Up) F4GC40CTIST
Accessories Center Cable Tap Box (Dn) F4GC20CBIST Accessories Center Cable Tap Box (Dn) F4GC40CBIST
Accessories End Box F4GC20EBIST Accessories End Box F4GC40EBIST
Accessories Flanged End w/ Lugs F4GC20FLIST Accessories Flanged End w/ Lugs F4GC40FLIST
Accessories Flanged End F4GC20FEIST Accessories Flanged End F4GC40FEIST

2500 Amps Three-Phase, Four-Wire Internal Ground Bar Hangers - Common to All Services
Component Type Product Number Component Type Product Number
Linear Lengths 10-ft. plug-in P4GC25SLI10 800 Amps Flatwise (st.) SBF16
Linear Lengths 10-ft. feeder F4GC25SLI10 1000 Amps Flatwise (st.) SBF22
Linear Lengths 10-ft. riser R4GC25SLI10 1200 Amps Flatwise (st.) SBF28
Fitting Elbows; Left F4GC25ELIST 1600Amps Flatwise (st.) SBF42
Fitting Elbows; Right F4GC25ERIST 2500 Amps Flatwise (st.) SBTF
Fitting Elbows; Up F4GC25EUIST 3000 Amps Flatwise (st.) SBTH
Fitting Elbows; Down F4GC25EDIST 4000 Amps Flatwise (st.) SBTH
Accessories End Cable Tap Box (Up) F4GC25TTIST 225-1600 Amps Edgewise (st.) SBE45
Accessories End Cable Tap Box (Dn) F4GC25TBIST 2000-5000 Amps Edgewise (st.) SBTE
Accessories Center Cable Tap Box (Up) F4GC25CTIST 1200 Amps Spring SBR1
Accessories Center Cable Tap Box (Dn) F4GC25CBIST 4000 Amps Spring SBR2
Accessories End Box F4GC25EBIST
Accessories Flanged End w/ Lugs F4GC25FLIST
Accessories Flanged End F4GC25FEIST

Copper, Four-Wire, Internal Ground

Rev. 11/13 www.geindustrial.com BuyLog Catalog 13-19


Data subject to change
without notice
Busway Section 13
Spectra RMS
Sandwich Bus
Circuit Breaker Busway Plugs

Features and Benefits Low-Tier Frames Three-Phase, Three-Wire SFHGA


Rating Plug: simplifies factory floor and equipment changeovers Short Circuit Short Circuit Short Circuit
Trip Rating Rating Rating Product
because plug has trip amp interchangeablility. Amps @ 240V (kAIC) @ 480V (kAIC) @ 600 V (kAIC) Number

True Digital rms Sensing: more accurate and reliable trip 70 65 25 18 SB37SFHG
90 65 25 18 SB39SFHG
interruption. 100 65 25 18 SB310SFHG
110 65 25 18 SB311SFHG
High Interrupting Rating: satisfies high IC requirements up to 125 65 25 18 SB312SFHG
100 kAIC @ 480V. 150 65 25 18 SB315SFHG
175 65 25 18 SB317SFHG
UL listed and CSA Certified for heat rise, short-circuit, and 200 65 25 18 SB320SFHG
ground fault. 225 65 25 18 SB322SFHG
250 65 25 18 SB325SFHG
Interlocks and Safety Features: door interlock, plug interlock,
ground contact before stab contact, and plug assist1 for
mechanical installation. Low-Tier Frames Three-Phase, Three-Wire SGH4GA (400A)
Short Circuit Short Circuit Short Circuit
Trip Rating Rating Rating Product
Amps @ 240V (kAIC) @ 480V (kAIC) @ 600 V (kAIC) Number
Low-Tier Frames Three-Phase, Three-Wire SEDGA
125 65 35 25 SB312SGH4G
Short Circuit Short Circuit Short Circuit 150 65 35 25 SB315SGH4G
Trip Rating Rating Rating Product 175 65 35 25 SB317SGH4G
Amps @ 240V (kAIC) @ 480V (kAIC) @ 600 V (kAIC) Number
200 65 35 25 SB320SGH4G
15 18 14 14 SB31SEDG 225 65 35 25 SB322SGH4G
20 18 14 14 SB32SEDG 250 65 35 25 SB325SGH4G
30 18 14 14 SB33SEDG 300 65 35 25 SB330SGH4G
40 18 14 14 SB34SEDG 350 65 35 25 SB335SGH4G
50 18 14 14 SB35SEDG 400 65 35 25 SB340SGH4G
60 18 14 14 SB36SEDG
70 18 14 14 SB37SEDG
80 18 14 14 SB38SEDG
90 18 14 14 SB39SEDG Low-Tier Frames Three-Phase, Three-Wire SGH6GA (600A)
100 18 14 14 SB310SEDG Short Circuit Short Circuit Short Circuit
110 18 14 14 SB311SEDG Trip Rating Rating Rating Product
125 18 14 14 SB312SEDG Amps @ 240V (kAIC) @ 480V (kAIC) @ 600 V (kAIC) Number
150 18 14 14 SB315SEDG 250 65 35 25 SB325SGH6G
300 65 35 25 SB330SGH6G
350 65 35 25 SB335SGH6G
400 65 35 25 SB340SGH6G
Low-Tier Frames Three-Phase, Three-Wire SEHGA
450 65 35 25 SB345SGH6G
Short Circuit Short Circuit Short Circuit 500 65 35 25 SB350SGH6G
Trip Rating Rating Rating Product 600 65 35 25 SB360SGH6G
Amps @ 240V (kAIC) @ 480V (kAIC) @ 600 V (kAIC) Number
15 65 25 18 SB31SEHG
20 65 25 18 SB32SEHG
30 65 25 18 SB33SEHG Low-Tier Frames Three-Phase, Three-Wire SKHGA
40 65 25 18 SB34SEHG Short Circuit Short Circuit Short Circuit
50 65 25 18 SB35SEHG Trip Rating Rating Rating Product
60 65 25 18 SB36SEHG Amps @ 240V (kAIC) @ 480V (kAIC) @ 600 V (kAIC) Number
70 65 25 18 SB37SEHG 300 65 50 25 SB330SKHG
80 65 25 18 SB38SEHG 400 65 50 25 SB340SKHG
90 65 25 18 SB39SEHG 500 65 50 25 SB350SKHG
100 65 25 18 SB310SEHG 600 65 50 25 SB360SKHG
110 65 25 18 SB311SEHG 700 65 50 25 SB370SKHG
125 65 25 18 SB312SEHG 800 65 50 25 SB380SKHG
150 65 25 18 SB315SEHG
1Optional for E Frame plugs.
Notes: Breakers must be factory-installed. IC rating in rms symmetrical kA.

13-20 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Busway Section 13
Spectra RMS (continued)
Sandwich Bus
Circuit Breaker Busway Plugs

Low-Tier Frames Three-Phase, Four-Wire SEDGA Low-Tier Frames Three-Phase, Four-Wire SGH6GA (600A)
Short Circuit Short Circuit Short Circuit Short Circuit Short Circuit Short Circuit
Trip Rating Rating Rating Product Trip Rating Rating Rating Product
Amps @ 240V (kAIC) @ 480V (kAIC) @ 600 V (kAIC) Number Amps @ 240V (kAIC) @ 480V (kAIC) @ 600 V (kAIC) Number
15 18 14 14 SB41SEDG 250 65 35 25 SB425SGH6G
20 18 14 14 SB42SEDG 300 65 35 25 SB430SGH6G
30 18 14 14 SB43SEDG 350 65 35 25 SB435SGH6G
40 18 14 14 SB44SEDG 400 65 35 25 SB440SGH6G
50 18 14 14 SB45SEDG 450 65 35 25 SB445SGH6G
60 18 14 14 SB46SEDG 500 65 35 25 SB450SGH6G
70 18 14 14 SB47SEDG 600 65 35 25 SB460SGH6G
80 18 14 14 SB48SEDG
90 18 14 14 SB49SEDG
100 18 14 14 SB410SEDG
110 18 14 14 SB411SEDG Low-Tier Frames Three-Phase, Four-Wire SKHGA
125 18 14 14 SB412SEDG Short Circuit Short Circuit Short Circuit
150 18 14 14 SB415SEDG Trip Rating Rating Rating Product
Amps @ 240V (kAIC) @ 480V (kAIC) @ 600 V (kAIC) Number
300 65 50 25 SB430SKHG
Low-Tier Frames Three-Phase, Four-Wire SEHGA 400 65 50 25 SB440SKHG
500 65 50 25 SB450SKHG
Short Circuit Short Circuit Short Circuit 600 65 50 25 SB460SKHG
Trip Rating Rating Rating Product 700 65 50 25 SB470SKHG
Amps @ 240V (kAIC) @ 480V (kAIC) @ 600 V (kAIC) Number
800 65 50 25 SB480SKHG
15 65 25 18 SB41SEHG
20 65 25 18 SB42SEHG
30 65 25 18 SB43SEHG
40 65 25 18 SB44SEHG Mid-Tier Frames Three-Phase, Three-Wire SELGA
50 65 25 18 SB45SEHG Short Circuit Short Circuit Short Circuit
60 65 25 18 SB46SEHG Trip Rating Rating Rating Product
70 65 25 18 SB47SEHG Amps @ 240V (kAIC) @ 480V (kAIC) @ 600 V (kAIC) Number
80 65 25 18 SB48SEHG
15 100 65 25 SB31SELG
90 65 25 18 SB49SEHG
20 100 65 25 SB32SELG
100 65 25 18 SB410SEHG
30 100 65 25 SB33SELG
110 65 25 18 SB411SEHG
40 100 65 25 SB34SELG
125 65 25 18 SB412SEHG
50 100 65 25 SB35SELG
150 65 25 18 SB415SEHG
60 100 65 25 SB36SELG
70 100 65 25 SB37SELG
80 100 65 25 SB38SELG
Low-Tier Frames Three-Phase, Four-Wire SFHGA 90 100 65 25 SB39SELG
100 100 65 25 SB310SELG
Short Circuit Short Circuit Short Circuit 110 100 65 25 SB311SELG
Trip Rating Rating Rating Product 125 100 65 25 SB312SELG
Amps @ 240V (kAIC) @ 480V (kAIC) @ 600 V (kAIC) Number
150 100 65 25 SB315SELG
70 65 25 18 SB47SFHG
90 65 25 18 SB49SFHG
100 65 25 18 SB410SFHG
110 65 25 18 SB411SFHG Mid-Tier Frames Three-Phase, Three-Wire SFLGA
125 65 25 18 SB412SFHG Short Circuit Short Circuit Short Circuit
150 65 25 18 SB415SFHG Trip Rating Rating Rating Product
175 65 25 18 SB417SFHG Amps @ 240V (kAIC) @ 480V (kAIC) @ 600 V (kAIC) Number
200 65 25 18 SB420SFHG
70 100 65 25 SB37SFLG
225 65 25 18 SB422SFHG
90 100 65 25 SB39SFLG
250 65 25 18 SB425SFHG
100 100 65 25 SB310SFLG
110 100 65 25 SB311SFLG
125 100 65 25 SB312SFLG
Low-Tier Frames Three-Phase, Four-Wire SGH4GA (400A) 150 100 65 25 SB315SFLG
175 100 65 25 SB317SFLG
Short Circuit Short Circuit Short Circuit 200 100 65 25 SB320SFLG
Trip Rating Rating Rating Product 225 100 65 25 SB322SFLG
Amps @ 240V (kAIC) @ 480V (kAIC) @ 600 V (kAIC) Number
250 100 65 25 SB325SFLG
125 65 35 25 SB412SGH4G
150 65 35 25 SB415SGH4G
175 65 35 25 SB417SGH4G
200 65 35 25 SB420SGH4G
225 65 35 25 SB422SGH4G
250 65 35 25 SB425SGH4G
300 65 35 25 SB430SGH4G
350 65 35 25 SB435SGH4G
400 65 35 25 SB440SGH4G

Rev. 11/13 www.geindustrial.com BuyLog Catalog 13-21


Data subject to change
without notice
Busway Section 13
Spectra RMS (continued)
Sandwich Bus
Circuit Breaker Busway Plugs

Mid-Tier Frames Three-Phase, Three-Wire SGL4GA Mid-Tier Frames Three-Phase, Four-Wire SFLGA
Short Circuit Short Circuit Short Circuit Short Circuit Short Circuit Short Circuit
Trip Rating Rating Rating Product Trip Rating Rating Rating Product
Amps @ 240V (kAIC) @ 480V (kAIC) @ 600 V (kAIC) Number Amps @ 240V (kAIC) @ 480V (kAIC) @ 600 V (kAIC) Number
125 100 65 65 SB312SGL4G 70 100 65 25 SB47SFLG
150 100 65 65 SB315SGL4G 90 100 65 25 SB49SFLG
175 100 65 65 SB317SGL4G 100 100 65 25 SB410SFLG
200 100 65 65 SB320SGL4G 110 100 65 25 SB411SFLG
225 100 65 65 SB322SGL4G 125 100 65 25 SB412SFLG
250 100 65 65 SB325SGL4G 150 100 65 25 SB415SFLG
300 100 65 65 SB330SGL4G 175 100 65 25 SB417SFLG
350 100 65 65 SB335SGL4G 200 100 65 25 SB420SFLG
400 100 65 65 SB340SGL4G 225 100 65 25 SB422SFLG
250 100 65 25 SB425SFLG

Mid-Tier Frames Three-Phase, Three-Wire SGL6GA


Short Circuit Short Circuit Short Circuit
Mid-Tier Frames Three-Phase, Four-Wire SGL4GA
Trip Rating Rating Rating Product Short Circuit Short Circuit Short Circuit
Amps @ 240V (kAIC) @ 480V (kAIC) @ 600 V (kAIC) Number Trip Rating Rating Rating Product
Amps @ 240V (kAIC) @ 480V (kAIC) @ 600 V (kAIC) Number
250 100 65 65 SB325SGL6G
300 100 65 65 SB330SGL6G 125 100 65 65 SB412SGL4G
350 100 65 65 SB335SGL6G 150 100 65 65 SB415SGL4G
400 100 65 65 SB340SGL6G 175 100 65 65 SB417SGL4G
450 100 65 65 SB345SGL6G 200 100 65 65 SB420SGL4G
500 100 65 65 SB350SGL6G 225 100 65 65 SB422SGL4G
600 100 65 65 SB360SGL6G 250 100 65 65 SB425SGL4G
300 100 65 65 SB430SGL4G
350 100 65 65 SB435SGL4G
400 100 65 65 SB440SGL4G
Mid-Tier Frames Three-Phase, Three-Wire SKLGA
Short Circuit Short Circuit Short Circuit
Trip Rating Rating Rating Product
Amps @ 240V (kAIC) @ 480V (kAIC) @ 600 V (kAIC) Number Mid-Tier Frames Three-Phase, Four-Wire SGL6GA
300 100 65 42 SB330SKLG Short Circuit Short Circuit Short Circuit
400 100 65 42 SB340SKLG Trip Rating Rating Rating Product
Amps @ 240V (kAIC) @ 480V (kAIC) @ 600 V (kAIC) Number
500 100 65 42 SB350SKLG
600 100 65 42 SB360SKLG 250 100 65 65 SB425SGL6G
700 100 65 42 SB370SKLG 300 100 65 65 SB430SGL6G
800 100 65 42 SB380SKLG 350 100 65 65 SB435SGL6G
400 100 65 65 SB440SGL6G
450 100 65 65 SB445SGL6G
500 100 65 65 SB450SGL6G
Mid-Tier Frames Three-Phase, Four-Wire SELGA 600 100 65 65 SB460SGL6G
Short Circuit Short Circuit Short Circuit
Trip Rating Rating Rating Product
Amps @ 240V (kAIC) @ 480V (kAIC) @ 600 V (kAIC) Number
Mid-Tier Frames Three-Phase, Four-Wire SKLGA
15 100 65 25 SB41SELG
20 100 65 25 SB42SELG Short Circuit Short Circuit Short Circuit
30 100 65 25 SB43SELG Trip Rating Rating Rating Product
Amps @ 240V (kAIC) @ 480V (kAIC) @ 600 V (kAIC) Number
40 100 65 25 SB44SELG
50 100 65 25 SB45SELG 300 100 65 42 SB430SKLG
60 100 65 25 SB46SELG 400 100 65 42 SB440SKLG
70 100 65 25 SB47SELG 500 100 65 42 SB450SKLG
80 100 65 25 SB48SELG 600 100 65 42 SB460SKLG
90 100 65 25 SB49SELG 700 100 65 42 SB470SKLG
100 100 65 25 SB410SELG 800 100 65 42 SB480SKLG
110 100 65 25 SB411SELG
125 100 65 25 SB412SELG
150 100 65 25 SB415SELG

Notes: Breakers must be factory-installed. IC rating in rms symmetrical kA.

13-22 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Busway Section 13
Spectra RMS (continued)
Sandwich Bus
Circuit Breaker Busway Plugs

Peak-Tier Frames Three-Phase, Three-Wire SEPGA Peak-Tier Frames Three-Phase, Three-Wire SKPGA
Short Circuit Short Circuit Short Circuit Short Circuit Short Circuit Short Circuit
Trip Rating Rating Rating Product Trip Rating Rating Rating Product
Amps @ 240V (kAIC) @ 480V (kAIC) @ 600 V (kAIC) Number Amps @ 240V (kAIC) @ 480V (kAIC) @ 600 V (kAIC) Number
15 200 100 25 SB31SEPG 300 200 100 25 SB330SKPG
20 200 100 25 SB32SEPG 400 200 100 25 SB340SKPG
30 200 100 25 SB33SEPG 500 200 100 25 SB350SKPG
40 200 100 25 SB34SEPG 600 200 100 25 SB360SKPG
50 200 100 25 SB35SEPG 700 200 100 25 SB370SKPG
60 200 100 25 SB36SEPG 800 200 100 25 SB380SKPG
70 200 100 25 SB37SEPG
80 200 100 25 SB38SEPG
90 200 100 25 SB39SEPG
100 200 100 25 SB310SEPG Peak-Tier Frames Three-Phase, Four-Wire SEPGA
110 200 100 25 SB311SEPG Short Circuit Short Circuit Short Circuit
125 200 100 25 SB312SEPG Trip Rating Rating Rating Product
150 200 100 25 SB315SEPG Amps @ 240V (kAIC) @ 480V (kAIC) @ 600 V (kAIC) Number
15 200 100 25 SB41SEPG
20 200 100 25 SB42SEPG
Peak-Tier Frames Three-Phase, Three-Wire SFPGA 30 200 100 25 SB43SEPG
40 200 100 25 SB44SEPG
Short Circuit Short Circuit Short Circuit 50 200 100 25 SB45SEPG
Trip Rating Rating Rating Product 60 200 100 25 SB46SEPG
Amps @ 240V (kAIC) @ 480V (kAIC) @ 600 V (kAIC) Number
70 200 100 25 SB47SEPG
70 200 100 25 SB37SFPG 80 200 100 25 SB48SEPG
90 200 100 25 SB39SFPG 90 200 100 25 SB49SEPG
100 200 100 25 SB310SFPG 100 200 100 25 SB410SEPG
110 200 100 25 SB311SFPG 110 200 100 25 SB411SEPG
125 200 100 25 SB312SFPG 125 200 100 25 SB412SEPG
150 200 100 25 SB315SFPG 150 200 100 25 SB415SEPG
175 200 100 25 SB317SFPG
200 200 100 25 SB320SFPG
225 200 100 25 SB322SFPG
250 200 100 25 SB325SFPG Peak-Tier Frames Three-Phase, Four-Wire SFPGA
Short Circuit Short Circuit Short Circuit
Trip Rating Rating Rating Product
Amps @ 240V (kAIC) @ 480V (kAIC) @ 600 V (kAIC) Number
Peak-Tier Frames Three-Phase, Three-Wire SGP4GA
70 200 100 25 SB47SFPG
Short Circuit Short Circuit Short Circuit 90 200 100 25 SB49SFPG
Trip Rating Rating Rating Product 100 200 100 25 SB410SFPG
Amps @ 240V (kAIC) @ 480V (kAIC) @ 600 V (kAIC) Number
110 200 100 25 SB411SFPG
125 200 100 65 SB312SGP4G 125 200 100 25 SB412SFPG
150 200 100 65 SB315SGP4G 150 200 100 25 SB415SFPG
175 200 100 65 SB317SGP4G 175 200 100 25 SB417SFPG
200 200 100 65 SB320SGP4G 200 200 100 25 SB420SFPG
225 200 100 65 SB322SGP4G 225 200 100 25 SB422SFPG
250 200 100 65 SB325SGP4G 250 200 100 25 SB425SFPG
300 200 100 65 SB330SGP4G
350 200 100 65 SB335SGP4G
400 200 100 65 SB340SGP4G
Peak-Tier Frames Three-Phase, Four-Wire SGP4GA
Short Circuit Short Circuit Short Circuit
Trip Rating Rating Rating Product
Peak-Tier Frames Three-Phase, Three-Wire SGP6GA Amps @ 240V (kAIC) @ 480V (kAIC) @ 600 V (kAIC) Number
Short Circuit Short Circuit Short Circuit 125 200 100 65 SB412SGP4G
Trip Rating Rating Rating Product 150 200 100 65 SB415SGP4G
Amps @ 240V (kAIC) @ 480V (kAIC) @ 600 V (kAIC) Number
175 200 100 65 SB417SGP4G
250 200 100 65 SB325SGP6G 200 200 100 65 SB420SGP4G
350 200 100 65 SB335SGP6G 225 200 100 65 SB422SGP4G
400 200 100 65 SB340SGP6G 250 200 100 65 SB425SGP4G
450 200 100 65 SB345SGP6G 300 200 100 65 SB430SGP4G
500 200 100 65 SB350SGP6G 350 200 100 65 SB435SGP4G
600 200 100 65 SB360SGP6G 400 200 100 65 SB440SGP4G

Notes: Breakers must be factory-installed. IC rating in rms symmetrical kA.

Rev. 11/13 www.geindustrial.com BuyLog Catalog 13-23


Data subject to change
without notice
Busway Section 13
Spectra RMS (continued)
Sandwich Bus
Circuit Breaker Busway Plugs

Peak-Tier Frames Three-Phase, Four-Wire SGP6GA Without Rating Plug Three-Phase, Four-Wire
Short Circuit Short Circuit Short Circuit Frame Type Trip Amps Product Number
Trip Rating Rating Rating Product
Amps @ 240V (kAIC) @ 480V (kAIC) @ 600 V (kAIC) Number SEDGA 15-30 SB401SEDG
SEDGA 40-60 SB402SEDG
250 200 100 65 SB425SGP6G SEDGA 70-100 SB403SEDG
350 200 100 65 SB435SGP6G SEDGA 110-150 SB404SEDG
400 200 100 65 SB440SGP6G SEHGA 15-30 SB401SEHG
450 200 100 65 SB445SGP6G SEHGA 40-60 SB402SEHG
500 200 100 65 SB450SGP6G SEHGA 70-100 SB403SEHG
600 200 100 65 SB460SGP6G SEHGA 110-150 SB404SEHG
SELGA 15-30 SB401SELG
SELGA 40-60 SB402SELG
SELGA 70-100 SB403SELG
Peak-Tier Frames Three-Phase, Four-Wire SKPGA SELGA 110-150 SB404SELG
Short Circuit Short Circuit Short Circuit SEPGA 15-30 SB401SEPG
Trip Rating Rating Rating Product SEPGA 40-60 SB402SEPG
Amps @ 240V (kAIC) @ 480V (kAIC) @ 600 V (kAIC) Number SEPGA 70-100 SB403SEPG
300 200 100 25 SB430SKPG SEPGA 110-150 SB404SEPG
400 200 100 25 SB440SKPG SFHGA 70-250 SB400SFHG
500 200 100 25 SB450SKPG SFLGA 70-250 SB400SFLG
600 200 100 25 SB460SKPG SFPGA 70-250 SB400SFPG
700 200 100 25 SB470SKPG SGH4GA 125-400 SB400SGH4G
800 200 100 25 SB480SKPG SGL4A 125-400 SB400SGL4G
SGP4GA 125-400 SB400SGP4G
SGH6GA 250-600 SB400SGH6G
SGL6GA 250-600 SB400SGL6G
Without Rating Plug Three-Phase, Three-Wire SGP6GA 250-600 SB400SGP6G
Frame Type Trip Amps Product Number SKHGA 300-800 SB400SKHG
SKLGA 300-800 SB400SKLG
SEDGA 15-30 SB301SEDG SKPGA 300-800 SB400SKPG
SEDGA 40-60 SB302SEDG
SEDGA 70-100 SB303SEDG Notes: Breakers must be factory-installed. IC rating in rms symmetrical kA.
SEDGA 110-150 SB304SEDG Order rating plug separately from BuyLog. Breakers must be factory-installed. Plug
SEHGA 15-30 SB301SEHG assist optional for E frame plugs.
SEHGA 40-60 SB302SEHG
SEHGA 70-100 SB303SEHG
SEHGA 110-150 SB304SEHG
SELGA 15-30 SB301SELG
SELGA 40-60 SB302SELG
SELGA 70-100 SB303SELG
SELGA 110-150 SB304SELG
SEPGA 15-30 SB301SEPG
SEPGA 40-60 SB302SEPG
SEPGA 70-100 SB303SEPG
SEPGA 110-150 SB304SEPG
SFHGA 70-250 SB300SFHG
SFLGA 70-250 SB300SFLG
SFPGA 70-250 SB300SFPG
SGH4GA 125-400 SB300SGH4G
SGL4A 125-400 SB300SGL4G
SGP4GA 125-400 SB300SGP4G
SGH6GA 250-600 SB300SGH6G
SGL6GA 250-600 SB300SGL6G
SGP6GA 250-600 SB300SGP6G
SKHGA 300-800 SB300SKHG
SKLGA 300-800 SB300SKLG
SKPGA 300-800 SB300SKPG

Notes: Breakers must be factory-installed. IC rating in rms symmetrical kA.

13-24 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Busway Section 13
Spectra RMS
Sandwich Bus
Circuit Breaker with MicroVersaTrip Plus Trip Units

Features and Benefits Low Tier Frames (Ground Fault) Three-Phase, Three-Wire
MicroVersaTrip Plus Trip Units Standard Frame Type Trip Amps Product Number

3-phase Ammeter with +/- accuracy SGHB 60 SB36SGHGF+


SGHB 80 SB38SGHGF+
Adjustable Long time (L) pickup, 0.5-1.0X, and delay SGHB 100 SB310SGHGF+
(3-4 bands). SGHB 125 SB312SGHGF+
Adjustable Instantaneous (I) pickup, 1.5-10X. SGHB 150 SB315SGHGF+
SGH4B 150 SB315SGH4GF+
Local Overload and Short Circuit Trip Indicators (T) with SGH4B 200 SB320SGH4GF+
overload pickup warning. SGH4B 225 SB322SGH4GF+
SGH4B 250 SB325SGH4GF+
Interchangeable trip rating plugs with test set jack for SGH4B 300 SB330SGH4GF+
TVRMS test set. SGH4B 350 SB335SGH4GF+
Digital LCD display with four-button keypad for function SGH4B 400 SB340SGH4GF+
SGH6B 300 SB330SGH6GF+
selection and set point adjustment and sealable clear Lexan SGH6B 400 SB340SGH6GF+
cover for tamper-resistant settings. SGH6B 450 SB345SGH6GF+
True rms sensing for accurate response to high harmonic SGH6B 500 SB350SGH6GF+
SGH6B 600 SB360SGH6GF+
content waveforms. SKHB 300 SB330SKHGF+
EMI immunity per ANSI C37.90. SKHB 400 SB340SKHGF+
SKHB 500 SB350SKHGF+
Optional SKHB 600 SB360SKHGF+
Adjustable Short Time (S) pickup, 1.0-9.0C, and delay SKHB 700 SB370SKHGF+
(4 bands) with l 2t IN/OUT selection. SKHB 800 SB380SKHGF+

Adjustable Ground fault (G) pickup, 0.2-1.0S, and delay


(4 bands) with l 2t IN/OUT selection and trip indicator. The
Low Tier Frames (Ground Fault) Three-Phase, Four-Wire
4 short time and ground fault delay bands provide broader
Frame Type Trip Amps Product Number
system selectivity
SGHB 60 SB46SGHGF+
SGHB 80 SB48SGHGF+
SGHB 100 SB410SGHGF+
SGHB 125 SB412SGHGF+
SGHB 150 SB415SGHGF+
SGH4B 150 SB415SGH4GF+
SGH4B 200 SB420SGH4GF+
SGH4B 225 SB422SGH4GF+
MicroVersaTrip Plus Trip Function SGH4B 250 SB425SGH4GF+
SGH4B 300 SB430SGH4GF+
Trip
SGH4B 350 SB435SGH4GF+
LIT
SGH4B 400 SB440SGH4GF+
LSIT
SGH6B 300 SB430SGH6GF+
With Ground Fault Option SGH6B 400 SB440SGH6GF+
SGH6B 450 SB445SGH6GF+
LIGT
SGH6B 500 SB450SGH6GF+
LSIGT
SGH6B 600 SB460SGH6GF+
Shunt Trip
SKHB 300 SB430SKHGF+
SKHB 400 SB440SKHGF+
SKHB 500 SB450SKHGF+
Trip Function Definitions SKHB 600 SB460SKHGF+
SKHB 700 SB470SKHGF+
Adjustable current setting
Long time (L) SKHB 800 SB480SKHGF+
Adjustable long-time delay
Adjustable short-time pick-up LIGT trip function is standard. LSIGT is additional.
Short Time (S) Adjustable short-time delay with l2t
Adjustable short-time delay without l2t
Instantaneous (I) Adjustable pick-up
Adjustable ground fault pick-up
Ground Fault (G) Adjustable ground fault delay with l2t
Adjustable ground fault delay without l2t
Trip Indication Targets Standard

Rev. 11/13 www.geindustrial.com BuyLog Catalog 13-25


Data subject to change
without notice
Busway Section 13
Spectra RMS
Sandwich Bus
Circuit Breaker with MicroVersa Trip Plus Trip Units

Low Tier Frames Three-Phase, Three-Wire Mid Tier Frames (Ground Fault) Three-Phase, Three-Wire
Frame Type Trip Amps Product Number Frame Type Trip Amps Product Number
SGHB 60 SB36SGHG+ SGLB 60 SB36SGLGF+
SGHB 80 SB38SGHG+ SGLB 80 SB38SGLGF+
SGHB 100 SB310SGHG+ SGLB 100 SB310SGLGF+
SGHB 125 SB312SGHG+ SGLB 125 SB312SGLGF+
SGHB 150 SB315SGHG+ SGLB 150 SB315SGLGF+
SGH4B 150 SB315SGH4G+ SGL4B 150 SB315SGL4GF+
SGH4B 200 SB320SGH4G+ SGL4B 200 SB320SGL4GF+
SGH4B 225 SB322SGH4G+ SGL4B 225 SB322SGL4GF+
SGH4B 250 SB325SGH4G+ SGL4B 250 SB325SGL4GF+
SGH4B 300 SB330SGH4G+ SGL4B 300 SB330SGL4GF+
SGH4B 350 SB335SGH4G+ SGL4B 350 SB335SGL4GF+
SGH4B 400 SB340SGH4G+ SGL4B 400 SB340SGL4GF+
SGH6B 300 SB330SGH6G+ SGL6B 300 SB330SGL6GF+
SGH6B 400 SB340SGH6G+ SGL6B 400 SB340SGL6GF+
SGH6B 450 SB345SGH6G+ SGL6B 450 SB345SGL6GF+
SGH6B 500 SB350SGH6G+ SGL6B 500 SB350SGL6GF+
SGH6B 600 SB360SGH6G+ SGL6B 600 SB360SGL6GF+
SKHB 300 SB330SKHG+ SKLB 300 SB330SKLGF+
SKHB 400 SB340SKHG+ SKLB 400 SB340SKLGF+
SKHB 500 SB350SKHG+ SKLB 500 SB350SKLGF+
SKHB 600 SB360SKHG+ SKLB 600 SB360SKLGF+
SKHB 700 SB370SKHG+ SKLB 700 SB370SKLGF+
SKHB 800 SB380SKHG+ SKLB 800 SB380SKLGF+

Low Tier Frames Three-Phase, Four-Wire Mid Tier Frames (Ground Fault) Three-Phase, Four-Wire
Frame Type Trip Amps Product Number Frame Type Trip Amps Product Number
SGHB 60 SB46SGHG+ SGLB 60 SB46SGLGF+
SGHB 80 SB48SGHG+ SGLB 80 SB48SGLGF+
SGHB 100 SB410SGHG+ SGLB 100 SB410SGLGF+
SGHB 125 SB412SGHG+ SGLB 125 SB412SGLGF+
SGHB 150 SB415SGHG+ SGLB 150 SB415SGLGF+
SGH4B 150 SB415SGH4G+ SGL4B 150 SB415SGL4GF+
SGH4B 200 SB420SGH4G+ SGL4B 200 SB420SGL4GF+
SGH4B 225 SB422SGH4G+ SGL4B 225 SB422SGL4GF+
SGH4B 250 SB425SGH4G+ SGL4B 250 SB425SGL4GF+
SGH4B 300 SB430SGH4G+ SGL4B 300 SB430SGL4GF+
SGH4B 350 SB435SGH4G+ SGL4B 350 SB435SGL4GF+
SGH4B 400 SB440SGH4G+ SGL4B 400 SB440SGL4GF+
SGH6B 300 SB430SGH6G+ SGL6B 300 SB430SGL6GF+
SGH6B 400 SB440SGH6G+ SGL6B 400 SB440SGL6GF+
SGH6B 450 SB445SGH6G+ SGL6B 450 SB445SGL6GF+
SGH6B 500 SB450SGH6G+ SGL6B 500 SB450SGL6GF+
SGH6B 600 SB460SGH6G+ SGL6B 600 SB460SGL6GF+
SKHB 300 SB430SKHG+ SKLB 300 SB430SKLGF+
SKHB 400 SB440SKHG+ SKLB 400 SB440SKLGF+
SKHB 500 SB450SKHG+ SKLB 500 SB450SKLGF+
SKHB 600 SB460SKHG+ SKLB 600 SB460SKLGF+
SKHB 700 SB470SKHG+ SKLB 700 SB470SKLGF+
SKHB 800 SB480SKHG+ SKLB 800 SB480SKLGF+

LIT trip function is standard. LSIT is additional. LIGT trip function is standard. LSIGT is additional.

13-26 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Busway Section 13
Spectra RMS (continued)
Sandwich Bus
Circuit Breaker with MicroVersa Trip Plus Trip Units

Mid Tier Frames Three-Phase, Three-Wire Peak Tier Frames (Ground Fault) Three-Phase, Three-Wire
Frame Type Trip Amps Product Number Frame Type Trip Amps Product Number
SGLB 60 SB36SGLG+ SGPB 60 SB36SGPGF+
SGLB 80 SB38SGLG+ SGPB 80 SB38SGPGF+
SGLB 100 SB310SGLG+ SGPB 100 SB310SGPGF+
SGLB 125 SB312SGLG+ SGPB 125 SB312SGPGF+
SGLB 150 SB315SGLG+ SGPB 150 SB315SGPGF+
SGL4B 150 SB315SGL4G+ SGP4B 150 SB315SGP4GF+
SGL4B 200 SB320SGL4G+ SGP4B 200 SB320SGP4GF+
SGL4B 225 SB322SGL4G+ SGP4B 225 SB322SGP4GF+
SGL4B 250 SB325SGL4G+ SGP4B 250 SB325SGP4GF+
SGL4B 300 SB330SGL4G+ SGP4B 300 SB330SGP4GF+
SGL4B 350 SB335SGL4G+ SGP4B 350 SB335SGP4GF+
SGL4B 400 SB340SGL4G+ SGP4B 400 SB340SGP4GF+
SGL6B 300 SB330SGL6G+ SGP6B 300 SB330SGP6GF+
SGL6B 400 SB340SGL6G+ SGP6B 400 SB340SGP6GF+
SGL6B 450 SB345SGL6G+ SGP6B 450 SB345SGP6GF+
SGL6B 500 SB350SGL6G+ SGP6B 500 SB350SGP6GF+
SGL6B 600 SB360SGL6G+ SGP6B 600 SB360SGP6GF+
SKLB 300 SB330SKLG+ SKPB 300 SB330SKPGF+
SKLB 400 SB340SKLG+ SKPB 400 SB340SKPGF+
SKLB 500 SB350SKLG+ SKPB 500 SB350SKPGF+
SKLB 600 SB360SKLG+ SKPB 600 SB360SKPGF+
SKLB 700 SB370SKLG+ SKPB 700 SB370SKPGF+
SKLB 800 SB380SKLG+ SKPB 800 SB380SKPGF+

Mid Tier Frames Three-Phase, Four-Wire Peak Tier Frames (Ground Fault) Three-Phase, Four-Wire
Frame Type Trip Amps Product Number Frame Type Trip Amps Product Number
SGLB 60 SB46SGLG+ SGPB 60 SB46SGPGF+
SGLB 80 SB48SGLG+ SGPB 80 SB48SGPGF+
SGLB 100 SB410SGLG+ SGPB 100 SB410SGPGF+
SGLB 125 SB412SGLG+ SGPB 125 SB412SGPGF+
SGLB 150 SB415SGLG+ SGPB 150 SB415SGPGF+
SGL4B 150 SB415SGL4G+ SGP4B 150 SB415SGP4GF+
SGL4B 200 SB420SGL4G+ SGP4B 200 SB420SGP4GF+
SGL4B 225 SB422SGL4G+ SGP4B 225 SB422SGP4GF+
SGL4B 250 SB425SGL4G+ SGP4B 250 SB425SGP4GF+
SGL4B 300 SB430SGL4G+ SGP4B 300 SB430SGP4GF+
SGL4B 350 SB435SGL4G+ SGP4B 350 SB435SGP4GF+
SGL4B 400 SB440SGL4G+ SGP4B 400 SB440SGP4GF+
SGL6B 300 SB430SGL6G+ SGP6B 300 SB430SGP6GF+
SGL6B 400 SB440SGL6G+ SGP6B 400 SB440SGP6GF+
SGL6B 450 SB445SGL6G+ SGP6B 450 SB445SGP6GF+
SGL6B 500 SB450SGL6G+ SGP6B 500 SB450SGP6GF+
SGL6B 600 SB460SGL6G+ SGP6B 600 SB460SGP6GF+
SKLB 300 SB430SKLG+ SKPB 300 SB430SKPGF+
SKLB 400 SB440SKLG+ SKPB 400 SB440SKPGF+
SKLB 500 SB450SKLG+ SKPB 500 SB450SKPGF+
SKLB 600 SB460SKLG+ SKPB 600 SB460SKPGF+
SKLB 700 SB470SKLG+ SKPB 700 SB470SKPGF+
SKLB 800 SB480SKLG+ SKPB 800 SB480SKPGF+

LIT trip function is standard. LSIT is additional. LIGT trip function is standard. LSIGT is additional.

Rev. 11/13 www.geindustrial.com BuyLog Catalog 13-27


Data subject to change
without notice
Busway Section 13
Spectra RMS (continued)
Sandwich Bus
Circuit Breaker with MicroVersa Trip Plus Trip Units

Peak Tier Frames Three-Phase, Three-Wire


Frame Type Trip Amps Product Number
SGPB 60 SB36SGPG+
SGPB 80 SB38SGPG+
SGPB 100 SB310SGPG+
SGPB 125 SB312SGPG+
SGPB 150 SB315SGPG+
SGP4B 150 SB315SGP4G+
SGP4B 200 SB320SGP4G+
SGP4B 225 SB322SGP4G+
SGP4B 250 SB325SGP4G+
SGP4B 300 SB330SGP4G+
SGP4B 350 SB335SGP4G+
SGP4B 400 SB340SGP4G+
SGP6B 300 SB330SGP6G+
SGP6B 400 SB340SGP6G+
SGP6B 450 SB345SGP6G+
SGP6B 500 SB350SGP6G+
SGP6B 600 SB360SGP6G+
SKPB 300 SB330SKPG+
SKPB 400 SB340SKPG+
SKPB 500 SB350SKPG+
SKPB 600 SB360SKPG+
SKPB 700 SB370SKPG+
SKPB 800 SB380SKPG+

Peak Tier Frames Three-Phase, Four-Wire


Frame Type Trip Amps Product Number
SGPB 60 SB46SGPG+
SGPB 80 SB48SGPG+
SGPB 100 SB410SGPG+
SGPB 125 SB412SGPG+
SGPB 150 SB415SGPG+
SGP4B 150 SB415SGP4G+
SGP4B 200 SB420SGP4G+
SGP4B 225 SB422SGP4G+
SGP4B 250 SB425SGP4G+
SGP4B 300 SB430SGP4G+
SGP4B 350 SB435SGP4G+
SGP4B 400 SB440SGP4G+
SGP6B 300 SB430SGP6G+
SGP6B 400 SB440SGP6G+
SGP6B 450 SB445SGP6G+
SGP6B 500 SB450SGP6G+
SGP6B 600 SB460SGP6G+
SKPB 300 SB430SKPG+
SKPB 400 SB440SKPG+
SKPB 500 SB450SKPG+
SKPB 600 SB460SKPG+
SKPB 700 SB470SKPG+
SKPB 800 SB480SKPG+

LIT trip function is standard. LSIT is additional.

13-28 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Busway Section 13
Spectra Series Busway
Sandwich Bus
Plugs, Fusible, Conversion Kits

Features and Benefits Standard Frames Three-Phase, Three-Wire TFK


Exclusive Plug Assist1: for mechanical installation. Voltage Trip Amps Product Number

Ground Contact: before stab contact. 600 Volts Inter. Trip 70 SB37FKG
600 Volts Inter. Trip 100 SB310FKG
Interlock: to insure that plug is off when engaging bus and 600 Volts Inter. Trip 125 SB312FKG
when removing plug. 600 Volts Inter. Trip 150 SB315FKG
Door Interlock: plug must be off to open door. 600 Volts Inter. Trip 200 SB320FKG
600 Volts Inter. Trip 225 SB322FKG

Standard Frames Three-Phase, Three-Wire TEB Standard Frames Three-Phase, Three-Wire TJJ
Voltage Trip Amps Product Number Voltage Trip Amps Product Number
240 Volts Fixed Trip 15 SB31EBG 600 Volts Fixed Trip 125 SB312JJG
240 Volts Fixed Trip 20 SB32EBG 600 Volts Fixed Trip 150 SB315JJG
240 Volts Fixed Trip 30 SB33EBG 600 Volts Fixed Trip 200 SB320JJG
240 Volts Fixed Trip 40 SB34EBG 600 Volts Fixed Trip 225 SB322JJG
240 Volts Fixed Trip 50 SB35EBG 600 Volts Fixed Trip 300 SB330JJG
240 Volts Fixed Trip 60 SB36EBG 600 Volts Fixed Trip 400 SB340JJG
240 Volts Fixed Trip 70 SB37EBG
240 Volts Fixed Trip 100 SB310EBG

Standard Frames Three-Phase, Three-Wire TJK4


Standard Frames Three-Phase, Three-Wire TED4 Voltage Trip Amps Product Number

Voltage Trip Amps Product Number 600 Volts Inter. Trip 125 SB312JK4G
600 Volts Inter. Trip 150 SB315JK4G
480 Volts Fixed Trip 15 SB31ED4G 600 Volts Inter. Trip 175 SB317JK4G
480 Volts Fixed Trip 20 SB32ED4G 600 Volts Inter. Trip 200 SB320JK4G
480 Volts Fixed Trip 30 SB33ED4G 600 Volts Inter. Trip 225 SB322JK4G
480 Volts Fixed Trip 40 SB34ED4G 600 Volts Inter. Trip 300 SB330JK4G
480 Volts Fixed Trip 50 SB35ED4G 600 Volts Inter. Trip 400 SB340JK4G
480 Volts Fixed Trip 60 SB36ED4G
480 Volts Fixed Trip 70 SB37ED4G
480 Volts Fixed Trip 100 SB310ED4G
Standard Frames Three-Phase, Three-Wire TJK6
Voltage Trip Amps Product Number
Standard Frames Three-Phase, Three-Wire TED6 600 Volts Inter. Trip 400 SB340JK6G
Voltage Trip Amps Product Number 600 Volts Inter. Trip 450 SB345JK6G
600 Volts Inter. Trip 500 SB350JK6G
600 Volts Fixed Trip 15 SB31ED6G 600 Volts Inter. Trip 600 SB360JK6G
600 Volts Fixed Trip 20 SB32ED6G
600 Volts Fixed Trip 30 SB33ED6G
600 Volts Fixed Trip 40 SB34ED6G
600 Volts Fixed Trip 50 SB35ED6G Standard Frames Three-Phase, Three-Wire TKM8
600 Volts Fixed Trip 60 SB36ED6G
Voltage Trip Amps Product Number
600 Volts Fixed Trip 70 SB37ED6G
600 Volts Fixed Trip 100 SB310ED6G 600 Volts Inter. Trip 300 SB330KMG
600 Volts Inter. Trip 400 SB340KMG
600 Volts Inter. Trip 500 SB350KMG
600 Volts Inter. Trip 600 SB360KMG
Standard Frames Three-Phase, Three-Wire TFJ 600 Volts Inter. Trip 700 SB370KMG
Voltage Trip Amps Product Number 600 Volts Inter. Trip 800 SB380KMG

600 Volts Fixed Trip 70 SB37FJG


600 Volts Fixed Trip 100 SB310FJG
600 Volts Fixed Trip 110 SB311FJG Standard Frames Three-Phase, Four-Wire TEB
600 Volts Fixed Trip 125 SB312FJG
Voltage Trip Amps Product Number
600 Volts Fixed Trip 150 SB315FJG
600 Volts Fixed Trip 200 SB320FJG 240 Volts Fixed Trip 15 SB41EBG
600 Volts Fixed Trip 225 SB322FJG 240 Volts Fixed Trip 20 SB42EBG
1Optional for E Frame plugs. 240 Volts Fixed Trip 30 SB43EBG
240 Volts Fixed Trip 40 SB44EBG
240 Volts Fixed Trip 50 SB45EBG
240 Volts Fixed Trip 60 SB46EBG
240 Volts Fixed Trip 70 SB47EBG
240 Volts Fixed Trip 100 SB410EBG

Rev. 11/13 www.geindustrial.com BuyLog Catalog 13-29


Data subject to change
without notice
Busway Section 13
Spectra Series Busway (continued)
Sandwich Bus
Plugs, Fusible, Conversion Kits

Standard Frames Three-Phase, Four-Wire TED4 Standard Frames Three-Phase, Four-Wire TJK4
Voltage Trip Amps Product Number Voltage Trip Amps Product Number
480 Volts Fixed Trip 15 SB41ED4G 600 Volts Inter. Trip 125 SB412JK4G
480 Volts Fixed Trip 20 SB42ED4G 600 Volts Inter. Trip 150 SB415JK4G
480 Volts Fixed Trip 30 SB43ED4G 600 Volts Inter. Trip 175 SB417JK4G
480 Volts Fixed Trip 40 SB44ED4G 600 Volts Inter. Trip 200 SB420JK4G
480 Volts Fixed Trip 50 SB45ED4G 600 Volts Inter. Trip 225 SB422JK4G
480 Volts Fixed Trip 60 SB46ED4G 600 Volts Inter. Trip 300 SB430JK4G
480 Volts Fixed Trip 70 SB47ED4G 600 Volts Inter. Trip 400 SB440JK4G
480 Volts Fixed Trip 100 SB410ED4G

Standard Frames Three-Phase, Four-Wire TJK6


Standard Frames Three-Phase, Four-Wire TED6 Voltage Trip Amps Product Number
Voltage Trip Amps Product Number
600 Volts Inter. Trip 400 SB440JK6G
600 Volts Fixed Trip 15 SB41ED6G 600 Volts Inter. Trip 450 SB445JK6G
600 Volts Fixed Trip 20 SB42ED6G 600 Volts Inter. Trip 500 SB450JK6G
600 Volts Fixed Trip 30 SB43ED6G 600 Volts Inter. Trip 600 SB460JK6G
600 Volts Fixed Trip 40 SB44ED6G
600 Volts Fixed Trip 50 SB45ED6G
600 Volts Fixed Trip 60 SB46ED6G
600 Volts Fixed Trip 70 SB47ED6G Standard Frames Three-Phase, Four-Wire TKM8
600 Volts Fixed Trip 100 SB410ED6G Voltage Trip Amps Product Number
600 Volts Inter. Trip 300 SB430KMG
600 Volts Inter. Trip 400 SB440KMG
Standard Frames Three-Phase, Four-Wire TFJ 600 Volts Inter. Trip 500 SB450KMG
600 Volts Inter. Trip 600 SB460KMG
Voltage Trip Amps Product Number
600 Volts Inter. Trip 700 SB470KMG
600 Volts Fixed Trip 70 SB47FJG 600 Volts Inter. Trip 800 SB480KMG
600 Volts Fixed Trip 100 SB410FJG
600 Volts Fixed Trip 110 SB411FJG
600 Volts Fixed Trip 125 SB412FJG
600 Volts Fixed Trip 150 SB415FJG Hi-Break Frames Three-Phase, Three-Wire THED
600 Volts Fixed Trip 200 SB420FJG Voltage Trip Amps Product Number
600 Volts Fixed Trip 225 SB422FJG
600 Volts Fixed Trip 15 SB31HEDG
600 Volts Fixed Trip 20 SB32HEDG
600 Volts Fixed Trip 30 SB33HEDG
Standard Frames Three-Phase, Four-Wire TFK 600 Volts Fixed Trip 40 SB34HEDG
600 Volts Fixed Trip 50 SB35HEDG
Voltage Trip Amps Product Number
600 Volts Fixed Trip 70 SB37HEDG
600 Volts Inter. Trip 70 SB47FKG 600 Volts Fixed Trip 100 SB310HEDG
600 Volts Inter. Trip 100 SB410FKG
600 Volts Inter. Trip 125 SB412FKG
600 Volts Inter. Trip 150 SB415FKG
600 Volts Inter. Trip 200 SB420FKG Hi-Break Frames Three-Phase, Three-Wire THFK
600 Volts Inter. Trip 225 SB422FKG Voltage Trip Amps Product Number
600 Volts Inter. Trip 70 SB37HFKG
600 Volts Inter. Trip 100 SB310HFKG
Standard Frames Three-Phase, Four-Wire TJJ 600 Volts Inter. Trip 125 SB312HFKG
600 Volts Inter. Trip 150 SB315HFKG
Voltage Trip Amps Product Number
600 Volts Inter. Trip 200 SB320HFKG
600 Volts Fixed Trip 125 SB412JJG 600 Volts Inter. Trip 225 SB322HFKG
600 Volts Fixed Trip 150 SB415JJG
600 Volts Fixed Trip 200 SB420JJG
600 Volts Fixed Trip 225 SB422JJG
600 Volts Fixed Trip 300 SB430JJG Hi-Break Frames Three-Phase, Three-Wire THJK4
600 Volts Fixed Trip 400 SB440JJG Voltage Trip Amps Product Number
600 Volts Inter. Trip 125 SB312HJK4G
600 Volts Inter. Trip 150 SB315HJK4G
600 Volts Inter. Trip 200 SB320HJK4G
600 Volts Inter. Trip 225 SB322HJK4G
600 Volts Inter. Trip 300 SB330HJK4G
600 Volts Inter. Trip 400 SB340HJK4G

13-30 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Busway Section 13
Spectra Series Busway (continued)
Sandwich Bus
Plugs, Fusible, Conversion Kits

Hi-Break Frames Three-Phase, Three-Wire THJK6 Hi-Break Frames Three-Phase, Four-Wire THKM8
Voltage Trip Amps Product Number Voltage Trip Amps Product Number
600 Volts Inter. Trip 400 SB340HJK6G 600 Volts Inter. Trip 300 SB430HKMG
600 Volts Inter. Trip 450 SB345HJK6G 600 Volts Inter. Trip 400 SB440HKMG
600 Volts Inter. Trip 500 SB350HJK6G 600 Volts Inter. Trip 500 SB450HKMG
600 Volts Inter. Trip 600 SB360HJK6G 600 Volts Inter. Trip 600 SB460HKMG
600 Volts Inter. Trip 700 SB470HKMG
600 Volts Inter. Trip 800 SB480HKMG

Hi-Break Frames Three-Phase, Three-Wire THKM8


Voltage Trip Amps Product Number
Tri-Break Frames Three-Phase, Three-Wire TB4
600 Volts Inter. Trip 300 SB330HKMG
Voltage Trip Amps Product Number
600 Volts Inter. Trip 400 SB340HKMG
600 Volts Inter. Trip 500 SB350HKMG 600 Volts Inter. Trip 125 SB312B4F14G
600 Volts Inter. Trip 600 SB360HKMG 600 Volts Inter. Trip 150 SB315B4F14G
600 Volts Inter. Trip 700 SB370HKMG 600 Volts Inter. Trip 200 SB320B4F14G
600 Volts Inter. Trip 800 SB380HKMG 600 Volts Inter. Trip 225 SB322B4F14G
600 Volts Inter. Trip 300 SB330B4F14G
600 Volts Inter. Trip 400 SB340B4F14G

Hi-Break Frames Three-Phase, Four-Wire THED


Voltage Trip Amps Product Number
Tri-Break Frames Three-Phase, Three-Wire TB6
600 Volts Fixed Trip 15 SB41HEDG
Voltage Trip Amps Product Number
600 Volts Fixed Trip 20 SB42HEDG
600 Volts Fixed Trip 30 SB43HEDG 600 Volts Inter. Trip 300 SB330B6J14G
600 Volts Fixed Trip 40 SB44HEDG 600 Volts Inter. Trip 400 SB340B6J14G
600 Volts Fixed Trip 50 SB45HEDG 600 Volts Inter. Trip 500 SB350B6J14G
600 Volts Fixed Trip 70 SB47HEDG 600 Volts Inter. Trip 600 SB360B6J14G
600 Volts Fixed Trip 100 SB410HEDG

Tri-Break Frames Three-Phase, Three-Wire TB8


Hi-Break Frames Three-Phase, Four-Wire THFK Voltage Trip Amps Product Number
Voltage Trip Amps Product Number
600 Volts Inter. Trip 600 SB360B8K22G
600 Volts Inter. Trip 70 SB47HFKG 600 Volts Inter. Trip 700 SB370B8K22G
600 Volts Inter. Trip 100 SB410HFKG 600 Volts Inter. Trip 800 SB380B8K22G
600 Volts Inter. Trip 125 SB412HFKG
600 Volts Inter. Trip 150 SB415HFKG
600 Volts Inter. Trip 200 SB420HFKG
600 Volts Inter. Trip 225 SB422HFKG Tri-Break Frames Three-Phase, Four-Wire TB4
Voltage Trip Amps Product Number
600 Volts Inter. Trip 125 SB412B4F14G
Hi-Break Frames Three-Phase, Four-Wire THJK4 600 Volts Inter. Trip 150 SB415B4F14G
600 Volts Inter. Trip 200 SB420B4F14G
Voltage Trip Amps Product Number
600 Volts Inter. Trip 225 SB422B4F14G
600 Volts Inter. Trip 125 SB412HJK4G 600 Volts Inter. Trip 300 SB430B4F14G
600 Volts Inter. Trip 150 SB415HJK4G 600 Volts Inter. Trip 400 SB440B4F14G
600 Volts Inter. Trip 200 SB420HJK4G
600 Volts Inter. Trip 225 SB422HJK4G
600 Volts Inter. Trip 300 SB430HJK4G
600 Volts Inter. Trip 400 SB440HJK4G Tri-Break Frames Three-Phase, Four-Wire TB6
Voltage Trip Amps Product Number
600 Volts Inter. Trip 300 SB430B6J14G
Hi-Break Frames Three-Phase, Four-Wire THJK6 600 Volts Inter. Trip 400 SB440B6J14G
600 Volts Inter. Trip 500 SB450B6J14G
Voltage Trip Amps Product Number
600 Volts Inter. Trip 600 SB460B6J14G
600 Volts Inter. Trip 400 SB440HJK6G
600 Volts Inter. Trip 450 SB445HJK6G
600 Volts Inter. Trip 500 SB450HJK6G
600 Volts Inter. Trip 600 SB460HJK6G Tri-Break Frames Three-Phase, Four-Wire TB8
Voltage Trip Amps Product Number
600 Volts Inter. Trip 600 SB460B8K22G
600 Volts Inter. Trip 700 SB470B8K22G
600 Volts Inter. Trip 800 SB480B8K22G

Rev. 11/13 www.geindustrial.com BuyLog Catalog 13-31


Data subject to change
without notice
Busway Section 13
Spectra Series Busway (continued)
Sandwich Bus
Plugs, Fusible, Conversion Kits

Adapter Kits Convert Spectra Series plugs to Armor-Clad Miscellaneous Plug Modifications
Amperage Product Number Plug AssistStandard for plugs over 100 amperes. Add suffix
30-100 SBAC1G P to the product number for plugs 100 amperes and below.
150-250 SBAC4G
400-800 SBAC5G Drip-Proof PlugsIncludes cover and stab gasketing. Add suffix
Ground stabs included. I to product number.
Splashproof (IP54) PlugsAdd suffix Z to the product number.
Adapter Kits Spectra MVT + OptionAdd suffix + to the product number.
Convert Spectra Series Bus Plugs to Spectra LowAmp Bus Include note describing type of trip unit.
Amperage Product Number
30-100 SBSL1G
200-225 SBSL4G
400-600 SBSL5G

(Style 2shipped after 5/95)


Ground stabs included.

Switch-Operated Fusible Plugs Three-Phase, Three-Wire


Voltage Amperage Product Number
240 VAC 30 SB321RG
240 VAC 60 SB322RG
240 VAC 100 SB323RG
240 VAC 200 SB324RG
240 VAC 400 SB325RG
240 VAC 600 SB326RG
480 or 600 VAC 30 SB361RG
480 or 600 VAC 60 SB362RG
480 or 600 VAC 100 SB363RG
480 or 600 VAC 200 SB364RG
480 or 600 VAC 400 SB365RG
480 or 600 VAC 600 SB366RG

With QMR Interrupter Fuses Not Included

Switch-Operated Fusible Plugs Three-Phase, Four-Wire


Voltage Amperage Product Number
240 VAC 30 SB421RG
240 VAC 60 SB422RG
240 VAC 100 SB423RG
240 VAC 200 SB424RG
240 VAC 400 SB425RG
240 VAC 600 SB426RG
480 or 600 VAC 30 SB461RG
480 or 600 VAC 60 SB462RG
480 or 600 VAC 100 SB463RG
480 or 600 VAC 200 SB464RG
480 or 600 VAC 400 SB465RG
480 or 600 VAC 600 SB466RG

With QMR Interrupter Fuses Not Included

13-32 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Busway Section 13
Spectra Series Busway
Sandwich Bus
Plug Options
Protective Devices and Short-Circuit Ratings

Enclosure Three-Phase, Three-Wire Ground Standard


Frame Type Trip Amps Product Number
E 100 max. SB3100EG
F 225 SB3225FG

Enclosure Three-Phase, Four-Wire Ground Standard


Frame Type Trip Amps Product Number
E 100 max. SB4100EG
F 225 SB4225FG

(Order circuit breaker from Section 6)


Not for Spectra breakers. E and F frame enclosures for standard molded case
circuit breakers only.

Contactor Plugs
Contactor Plugs are available in 30, 60 and 100 amps and have
the following options:
Electronically Held
Mechanically Held
Pilot Lights
Pushbutton
Selector Switches
Control Transformers
Extra Interlocks
Two-Wire Controls
Auxiliary Contacts
Contact the factory for pricing details.

Options for Fusible Switch Units


Use for Spectra Series Busway
Fusible Switch Units are available in 30, 60, 100, 200, 400 and 600
amps and have the following options:
Factory installed Class R fuse clips
Factory installed Class J fuse clips
QMW in lieu of QMR
Contact the factory for pricing details.

Rev. 11/13 www.geindustrial.com BuyLog Catalog 13-33


Data subject to change
without notice
Busway Section 13
Spectra Series Busway
Sandwich Bus
Plug Options
Protective Devices and Short-Circuit Ratings
Spectra Bus Plugs with Tranquell TVSS Protection
Spectra bus plugs are available with integral Tranquell TVSS
devices for a variety of location categories and exposure levels.
Indicating lights communicate proper system operation. Ratings
and specifications:
Suitable for medium to high exposure, service entry or branch
panel locations
UL-1449, Second Edition; cUL and UL-1283 Recognized
Component
Maximum surge current ratings of 50kA, 80kA, and 100kA per Spectra TVSS bus plugs
modetested on a complete TVSS unit
Repetitive surge current testedANSI/IEEE C62.41, Category C3:
100kA-5,000 impulses; 80kA-5,000 impulses; 50kA-3,500 impulses
Noise filtering up to -44dB at 100kHz
Refer to FES-006 for UL-1449, Second Edition SVR Values
65 kAIC

Spectra Bus Plugs with TVSS Protection Three-Phase, Three-Wire


Maximum Surge
Current Rating Voltage Power Type Ground Fault TVSS Product Number Product Number
100kA 240V Delta Delta Yes TME240D100 SB310TVSS240D
100kA 480V Delta Delta Yes TME480D100 SB310TVSS480D
100kA 600V Delta Delta Yes TME600D100 SB310TVSS600D

Spectra Bus Plugs with TVSS Protection Three-Phase, Four-Wire


Maximum Surge
Current Rating Voltage Power Type Ground Fault TVSS Product Number Product Number
100kA 208Y/120V Wye Yes TME120Y100 SB410TVSS208Y
100kA 240Y/138V Wye Yes TME240Y100 SB410TVSS240Y
100kA 480Y/277V Wye Yes TME277Y100 SB410TVSS480Y
100kA 600Y/346V Wye Yes TME347Y100 SB410TVSS600Y

Spectra Bus Plugs with TVSS Protection Three-Phase, Three-Wire


Maximum Surge
Current Rating Voltage Power Type Ground Fault TVSS Product Number Product Number
80kA 240V Delta Delta Yes TME240D080 SB38TVSS240D
80kA 480V Delta Delta Yes TME480D080 SB38TVSS480D
80kA 600V Delta Delta Yes TME600D080 SB38TVSS600D

Spectra Bus Plugs with TVSS Protection Three-Phase, Four-Wire


Maximum Surge
Current Rating Voltage Power Type Ground Fault TVSS Product Number Product Number
80kA 208Y/120V Wye Yes TME120Y080 SB48TVSS208Y
80kA 240Y/138V Wye Yes TME240Y080 SB48TVSS240Y
80kA 480Y/277V Wye Yes TME277Y080 SB48TVSS480Y
80kA 600Y/346V Wye Yes TME347Y080 SB48TVSS600Y

Spectra Bus Plugs with TVSS Protection Three-Phase, Three-Wire


Maximum Surge
Current Rating Voltage Power Type Ground Fault TVSS Product Number Product Number
50kA 240V Delta Delta Yes TME240D065 SB35TVSS240D
50kA 480V Delta Delta Yes TME480D065 SB35TVSS480D
50kA 600V Delta Delta Yes TME600D065 SB35TVSS600D

Spectra Bus Plugs with TVSS Protection Three-Phase, Four-Wire


Maximum Surge
Current Rating Voltage Power Type Ground Fault TVSS Product Number Product Number
50kA 208Y/120V Wye Yes TME120Y065 SB45TVSS208Y
50kA 240Y/138V Wye Yes TME240Y065 SB45TVSS240Y
50kA 480Y/277V Wye Yes TME277Y065 SB45TVSS480Y
50kA 600Y/346V Wye Yes TME347Y065 SB45TVSS600Y

13-34 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Busway Section 13
Spectra Series Busway
Sandwich Bus
Plugs
Outlines and Dimensions

Spectra RMS Circuit Breaker Busway Plugs Outer Dimensions


Frame Width Length Depth Handle Weight Plug-in
Tier Type (in.) (in.) (in.) Height1 (Lbs.) Outlets Figure
Lowest SED 11 13 8 9.12 25 1 A
Low SEH 11 13 8 9.12 25 1 A
Low SFH 11 21.25 9 9.5 41 1 A
Low SGH 16.75 26.5 12 18 91 2 B
Low SKH2 16.75 36.5 12 18 160 2 B
Mid SEL 11 13 8 9.12 25 1 A Typical Vertical Application
Mid SFL 11 21.25 9 9.5 41 1 A
Mid SGL 16.75 26.5 12 18 91 2 B
Mid SKL2 16.75 36.5 12 18 160 2 B
Peak SEP 11 13 8 9.12 25 1 A
Peak SFP 11 21.25 9 9.5 41 1 A
Peak SGP 16.75 26.5 12 18 91 2 B
Peak SKP2 16.75 36.5 12 18 160 2 B
1Maximum distance from enclosure bottom to handle tip.
2For ground fault option, increase width dimension by 2.125 inches and length dimension by 6 inches.

Standard Molded Case Circuit Breaker


Type Frame Type Width (in.) Length (in.) Depth (in.) Figure
TEB 11 13 8 A
TED4 11 13 8 A
THED 11 13 8 A
TFJ 11 18.5 9.5 A
TFK 11 18.5 9.5 A
Standard and THFK 11 18.5 9.5 A
Hi-Break TJJ 16.75 24.5 12 B
TJK4 16.75 24.5 12 B
TJK6 16.75 24.5 12 B Figure A: Door hinges at left end.
THJK4 16.75 24.5 12 B
THJK6 16.75 24.5 12 B
All dimensions are shown over
TKM8, THKM8, THK, KM 16.75 36.5 12 A largest part of plug.
TB1 11.00 18.50 8 A
TB4 16.75 30.5 12 B
Tri-Break
TB6 16.75 45.25 12 B
TB8 16.75 45.25 12 B

Fusible Outer Dimensions


Length (in.) Length (in.)
Weight Width Standard Extended Depth
Type Voltage Amperage (Lbs.) (in.) Gutter Gutter (in.) Figure
QMR 240 and 600 VAC 30 24 11.25 13 18.75 8.75 A
QMR 240 and 600 VAC 60 25 11.25 13 18.75 8.75 A
QMR 240 and 600 VAC 100 28 11.25 18.75 N/A 8.75 A
QMR 240 and 600 VAC 200 46 16 18.75 24.5 8.75 A
QMR 240 and 600 VAC 400 135 20.5 18.75 N/A 18.75 B
QMR 240 and 600 VAC 600 160 20.5 24.5 N/A 18.75 B

NA = Not Available

Figure B: Door hinges top.


All dimensions are shown
over largest part of plug.

Decimal Fraction
.12 1/8
.38 3/8
.63 5/8
.88 7/8

Rev. 11/13 www.geindustrial.com BuyLog Catalog 13-35


Data subject to change
without notice
Busway Section 13
Spectra Series Busway
Sandwich Bus
Dimensions and Weights

Aluminum Three-Phase, Three-Wire


A width Bar Sizes DC Ampere Approx. Weight
Amperage Figure No. inches (mm) Width x Thickness (in.) Rating Lbs./Ft.
225 Amps 1 4.38 (111) 1.63 x .25 600 5
400 Amps 1 4.38 (111) 1.63 x .25 5 Figure 1: One Bar Per Phase
600 Amps 1 4.38 (111) 1.63 x .25 800/1000 5
800 Amps 1 5.63 (143) 2.88 x .25 1350 6
1000 Amps 1 6.13 (154) 3.38 x .25 1600 7
1200 Amps 1 7.00 (178) 4.25 x .25 8
1350 Amps 1 8.50 (216) 5.75 x .25 2500 9
1600 Amps 1 9.25 (235) 6.50 x .25 10
2000 Amps 1 11.00 (279) 8.25 x .25 3000 12
2500 Amps 2 15.50 (394) (2) 4.50 x .25 4000 17
3000 Amps 2 18.00 (457) (2) 5.75 x .25 19
4000 Amps 2 23.00 (584) (2) 8.25 x .25 6000 25

Aluminum Three-Phase, Four-Wire Figure 2: Two Bars Per Phase


A width Bar Sizes DC Ampere Approx. Weight
Amperage Figure No. inches (mm) Width x Thickness (in.) Rating Lbs./Ft.
225 Amps 1 4.38 (111) 1.63 x .25 600 6
400 Amps 1 4.38 (111) 1.63 x .25 6
600 Amps 1 4.38 (111) 1.63 x .25 800/1000 6
800 Amps 1 5.63 (143) 2.88 x .25 1350 7
1000 Amps 1 6.13 (154) 3.38 x .25 1600 8
1200 Amps 1 7.00 (178) 4.25 x .25 9
1350 Amps 1 8.50 (216) 5.75 x .25 2500 10
1600 Amps 1 9.25 (235) 6.50 x .25 12
2000 Amps 1 11.00 (279) 8.25 x .25 3000 15
2500 Amps 2 15.50 (394) (2) 4.50 x .25 4000 20
3000 Amps 2 18.00 (457) (2) 5.75 x .25 23 Plug-In Bus; Plug Outlet Locations
4000 Amps 2 23.00 (584) (2) 8.25 x .25 6000 30

Copper Three-Phase, Three-Wire


A width Bar Sizes DC Ampere Approx. Weight
Amperage Figure No. inches (mm) Width x Thickness (in.) Rating Lbs./Ft.
225 Amps 1 4.38 (111) 1.63 x .25 800 8
400 Amps 1 4.38 (111) 1.63 x .25 8
600 Amps 1 4.38 (111) 1.63 x .25 8
800 Amps 1 4.38 (111) 1.63 x .25 1000/1200 8
1000 Amps 1 5.00 (127) 2.25 x .25 1350/1600 10
1200 Amps 1 5.63 (143) 2.88 x .25 12
1350 Amps 1 6.13 (156) 3.38 x .25 2000 14 Riser Bus: Plug Outlet Locations
1600 Amps 1 7.00 (178) 4.25 x .25 2500 16
2000 Amps 1 8.50 (216) 5.75 x .25 3000 21
2500 Amps 1 10.25 (260) 7.50 x .25 4000 26
3000 Amps 2 14.50 (368) (2) 4.00 x .25 5000 32
4000 Amps 2 18.00 (457) (2) 5.75 x .25 6000 42
5000 Amps 2 21.50 (546) (2) 7.50 x .25 8000 52

Copper Three-Phase, Four-Wire


A width Bar Sizes DC Ampere Approx. Weight
Amperage Figure No. inches (mm) Width x Thickness (in.) Rating Lbs./Ft.
225 Amps 1 4.38 (111) 1.63 x .25 800 9
Typical Plug Mounting
400 Amps 1 4.38 (111) 1.63 x .25 9
600 Amps 1 4.38 (111) 1.63 x .25 9
800 Amps 1 4.38 (111) 1.63 x .25 1000/1200 9
1000 Amps 1 5.00 (127) 2.25 x .25 1350/1600 12
1200 Amps 1 5.63 (143) 2.88 x .25 15
1350 Amps 1 6.13 (156) 3.38 x .25 2000 17
1600 Amps 1 7.00 (178) 4.25 x .25 2500 20
2000 Amps 1 8.50 (216) 5.75 x .25 3000 26
2500 Amps 1 10.25 (260) 7.50 x .25 4000 33
3000 Amps 2 15.00 (381) (2) 4.25 x .25 5000 40
4000 Amps 2 18.00 (457) (2) 5.75 x .25 6000 52
5000 Amps 2 21.50 (546) (2) 7.50 x .25 8000 66

Nominal Position

13-36 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Busway Section 13
Spectra Series Busway
Sandwich Bus
Dimensions and Weights
Turns Flat Tees1
Standard Dimensions (Inches)
Amps X Y Z
Al 225-1200 12 12 12
1350-3000 18 18 18
4000 24 24 24
Cu 225-1600 12 12 12
2000-4000 18 18 18
5000 24 24 24

Elbows (Up) Elbows (Right) Flat Offsets1


Standard Dimensions (Inches)
Amps X Y Z
Al 225-1350 12 5 12
1600-3000 18 5 18
4000 24 8 24
Cu 225-2000 12 5 12
2500-4000 18 5 18
5000 24 8 24

Combination Quick Elbows1


Standard Dimensions (Inches)
Tees (Down) Tees (Right) Amps X Y Z
Al 225-1350 10 8 12
1600-2500 10 12 18
3000-4000 10 16 24
Cu 225-2000 10 8 12
2500-3000 10 12 18
4000-5000 10 16 24
1
All dimensions are to center line.

Field Check Pieces and Replacement Pieces1

Offsets (Down) Offsets (Right)

Combination Elbow
Flat Elbows1
Standard Dimensions (Inches)
Amp X Y
Al 225-1350 12 12
1600-3000 18 18
4000 24 24
Cu 225-2000 12 12
2500-4000 18 18
5000 24 24

NOTE: For dimensions of flanged-end stubs, refer to GET-7005.

Rev. 11/13 www.geindustrial.com BuyLog Catalog 13-37


Data subject to change
without notice
Busway Section 13
Spectra Series Busway
Sandwich Bus
Dimensions and Weights
Joint Elbows
Centerline to Centerline Dimensions
Configuration Amperage Bar Width Flatwise Joint Elbow Edgewise Joint Elbow
Inches mm Inches mm
Single Stack Al 225-800 1.63-2.88 3 76 6 152
Cu 225-1200
Al 1000-1200 3.38-4.50 4 102 6 152
Cu 1350-1600
Al 1350-2000 5.75-8.25 5 127 6 152
Cu 2000-2500
Double Stack Al-2500 4.25-4.5 8 203 6 152
Cu-3000 Flatwise joint elbow (indoor only)
Al-3000 5.75-6.50 10 254 6 152
Cu-4000
Al-4000 7.5-8.25 12 305 6 152
Cu-5000

Edgewise joint elbow (indoor only)

13-38 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Busway Section 13
Spectra Series Busway
Sandwich Bus
Dimensions and Weights
End Cable Tap Boxes
No. of Conductor C Cable No. of #2-600kcmil
Stacks Material Amperage Width (in.) Height (in.) Bend Space Lugs/ N & GRD
1 Aluminum 225 Amps 17 26 15 1
1 Aluminum 400 Amps 17 26 15 2
1 Aluminum 600 Amps 17 26 15 2
1 Aluminum 800 Amps 17 26 15 3
1 Aluminum 1000 Amps 17 26 15 3
1 Aluminum 1200 Amps 20 29 18 4
1 Aluminum 1350 Amps 20 29 18 4
1 Aluminum 1600 Amps 20 29 18 5 End Tap Box: Feeder or Plug-In
1 Aluminum 2000 Amps 26 29 18 6
2 Aluminum 2500 Amps 26 29 18 8
2 Aluminum 3000 Amps 33 34 23 9
2 Aluminum 4000 Amps 33 34 23 12
1 Copper 225 Amps 17 26 15 1
1 Copper 400 Amps 17 26 15 2
1 Copper 600 Amps 17 26 15 2
1 Copper 800 Amps 17 26 15 3
1 Copper 1000 Amps 17 26 15 3 A B C N
1 Copper 1200 Amps 20 29 18 4
1 Copper 1350 Amps 20 29 18 4 " SIDE"
1 Copper 1600 Amps 20 29 18 5
1 Copper 2000 Amps 26 29 18 6 Standard Box Down Position, Side View
1 Copper 2500 Amps 26 29 18 8
2 Copper 3000 Amps 33 34 23 9
2 Copper 4000 Amps 33 34 23 12
2 Copper 5000 Amps 39 34 23 15

Center Cable Tap Boxes


No. of Conductor C Cable No. of #2-600kcmil
Stacks Material Amperage Width (in.) E L Bend Space Lugs/ N & GRD
1 Aluminum 225 Amps 24 4.38 20 15 1
1 Aluminum 400 Amps 24 4.38 20 15 2
1 Aluminum 600 Amps 24 4.38 20 15 2
1 Aluminum 800 Amps 24 4.38 20 15 3
1 Aluminum 1000 Amps 24 4.38 20 15 3 Inverted Box Up Position, Side View
1 Aluminum 1200 Amps 30 6 28 18 4
1 Aluminum 1350 Amps 30 6 28 18 4
1 Aluminum 1600 Amps 30 6 28 18 5
1 Aluminum 2000 Amps 36 9 28 18 6
2 Aluminum 2500 Amps 36 9 32 18 8
2 Aluminum 3000 Amps 48 12.75 39 23 9
2 Aluminum 4000 Amps 48 12.75 39 23 12
1 Copper 225 Amps 24 4.38 20 15 1
1 Copper 400 Amps 24 4.38 20 15 2
1 Copper 600 Amps 24 4.38 20 15 2
1 Copper 800 Amps 24 4.38 20 15 3
1 Copper 1000 Amps 24 4.38 20 15 3
1 Copper 1200 Amps 30 6 28 18 4
1 Copper 1350 Amps 30 6 28 18 4
1 Copper 1600 Amps 30 6 28 18 5 Center Tap Box: Feeder or Plug-in
1 Copper 2000 Amps 36 9 28 18 6
1 Copper 2500 Amps 36 9 32 18 8
2 Copper 3000 Amps 48 12.75 39 23 9
2 Copper 4000 Amps 48 12.75 39 23 12
2 Copper 5000 Amps 48 12.75 46 23 15

2000 Amp (Max.) Center Branch Tap Boxes


Number of
#2-600
"C" Cable kcmil
No. of
Aluminum Copper
Bend Lugs/
Inverted Box Up Position, Side View
Stacks Amperage Width Dimension "E" Length Width Dimension "E" Length Space N & Grd
1 2500 36 9 28 18 6
2500 36 9 28 18 6
3000 43 12.75 28 43 12.75 28 18 6
2
4000 43 12.75 28 43 12.75 28 18 6
5000 43 12.75 28 18 6

Mechanical-type (CU-AI wires) lugs standard; Crimp-type optional. Important: Local code requirements can affect
Standard Box Down Position, Side View
the dimensions, number of lugs furnished, etc. In these situations, refer to Company.

Rev. 11/13 www.geindustrial.com BuyLog Catalog 13-39


Data subject to change
without notice
Busway Section 13
Spectra Series Busway
Sandwich Bus
Dimensions and Weights

Alternate Cable Tap Boxes

Dimensions, Cable Bending Space and Lug Data (Inches)


Number of
"C " #2-600 kcmil
No. Aluminum Copper Cable Lugs Per
of Bend Phase,
Stacks Amps W L W L Space N&G
225 17 26 17 26 15 1
400 17 26 17 26 15 2
600 17 26 17 26 15 2
800 17 26 17 26 15 3
1000 17 26 17 26 15 3
1
1200 20 29 20 29 18 4
1350 20 29 20 29 18 4
1600 20 29 20 29 18 5
2000 26 29 26 29 18 6
2500 26 29 18 8
2500 26 29 18 8
3000 33 34 33 34 23 9
2
4000 33 34 33 34 23 12
5000 39 34 23 15

Alternate End Tap Box: Feeder or Plug-In

Inverted Box Up Position, Side View

Box Down Position, Side View

13-40 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Busway Section 13
Spectra Series Busway (continued)
Sandwich Bus
Dimensions and Weights

Transformer Taps

Standard Lug Position

Three-Phase End Tap

Single-Phase Transformer Taps

Dimensions and Lug Data (Inches)


No . Number of
of Aluminum Copper #2-600 kcmil
Stacks Amps W W Lugs Per Phase 1
1000 16 2
1200 16 16 3
1350 20 16 3
1
1600 20 16 3
2000 20 20 4
2500 20 5
2500 24 5
3000 32 24 6
2
4000 32 32 8

Single-Phase Transformer Taps
5000 32 10
1 Mechanical-type (Cu-Al wire) lugs standard; Crimp-type optional.
One ground lug standard through 3000 Amp Cu. Two ground lugs
standard for 4000 Amp Al, 5000 Amp Cu. Optional one ground lug
per phase lug.
2 24" dimension changes to 28" for 5000 Amp or when 100% ground lugs
are required.

Three-Phase End Tap


Dimensions and Lug Data (Inches)
No. Number of
of Aluminum Copper #2-600 kcmil Lugs
Stacks Amps W W Per Phase, N & G
600 17 17 2
800 17 17 2
1000 17 17 2
1200 20 20 3
1
1350 20 20 3
1600 20 20 3
2000 26 26 4
2500 26 5
2500 26 5
3000 33 33 6
2
4000 33 33 8
5000 39 10

Rev. 11/13 www.geindustrial.com BuyLog Catalog 13-41


Data subject to change
without notice
Busway Section 13
Spectra Series Busway
Sandwich Bus
Dimensions

Hangers
Vertical MountingSpring Hangers (Must be ordered separately)
Spring hangers should be ordered to support the busway at each floor if floor-to-floor
span is less than 16 feet. When the floor-to-floor span is over 16 feet, supports and
additional spring hangers are required on 16 foot centers maximum. The quantity of Product Number SBR X
springs supplied is based on total weight of busway and devices installed per floor. Common to All Services
Simple adjustment procedures are included with installation instructions. Mounting holes Note: Floor or wall opening should provide
align with floor flanges. 1/2 clearance all around busway.
Product Number (SBR X) where X = Quantity of springs (1 or 2) on each side of hanger
(single spring up to 600 lbs. per floor).
Refer to Installation Instructions DEH-40087 for A Dimension.

Horizontal MoutingOne-Stack Clevis Hangers1


One-Stack Flatwise Hangers
Product Number Conductor Material Amperage Bar Width
SBF16 Aluminum 225-600 Amps 1.63
Copper 225-800 Amps
SBF22 Copper 1000 Amps 2.25
SBF28 Aluminum 800 Amps 2.88
Copper 1200 Amps
One-Stack (Standard) Flatwise
SBF33 Aluminum 1000 Amps 3.38 Product Number SBF XX 2
Copper 1350 Amps
SBF42 Aluminum 1200 Amps 4.25
Copper 1600 Amps
SBF57 Aluminum 1350 Amps 5.75
SBF65 Aluminum 1600 Amps 6.50
SBF82 Aluminum 2000 Amps 8.25
1Furnished every 10 feet. Requires 0.50 inch diameter drop rods.

Horizontal MoutingTrapeze Hangers1


One- or Two-Stack Flatwise Trapeze
Product Number No. of Stacks Bar Width Width (in.)
SBTE 1 1.63-4.25 10.25 One-Stack Edgewise Product Number
SBTF 1 5.75-8.25 14
SBTG 2 4.25-4.50 18.5 SBE45 (Up to 2000 Amp Max.)
SBTH 2 5.75-6.50 22.5
SBTJ 2 8.25 26
1Furnished every 10 feet. Requires 0.50 inch diameter drop rods.
2Available for up to 2000A Al or 1600A Cu Busway.

Horizontal Mounting - Trapeze Hangers.


One Furnished every 10 feet . Requires
(2) 0.50 inch diameter drop rods.

Edgewise Trapeze Product No. SBTE

13-42 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Busway Section 13
Spectra Series Busway Power Takeoff Device Dimensions (Fig. 2)
Sandwich Bus
Power Takeoffs Rating Type "H " " W" "D "
Dimensions 100A QMR 17.75 9.38 6.75
200A QMR 24.38 15.50 7.25
400A QMR 18 18.50 17.56
Power Takeoffs (PTO)1 400A QMW 18 18.50 17.56
Spectra Series Flex-A-Tap joints accept bolted power takeoff 600A QMR 24 18.50 17.56
devices up to 1600 amps for many applications. 800A & 1200A QMR 45.13 36.75 12.75
The compact size and flexibility resulting from the modular 225A FJ 17.75 9.75 7.75

design allow takeoffs to be mounted at any joint, whether feeder 400A JJ 24 15.50 10.75

or plug-in. See Fig. 1. 600A JK 24 15.50 10.75


600-800A KM 36 15.50 10.75
Bolt-On Tap Amp Rating 1200A K4V, KL4V, KM, KH, KL
45.50 15.50 10.75
Fusible Switches (600A QMW Only) 600 With or Without Ground Fault
400A TB4 Tri-Break 30 15.50 10.75
Molded-Case Circuit Breakers (KM & PB Only) 1600A Max
600A TB6 Tri-Break 44.75 15.50 10.75
Cable Boxes 1600 Max
800A TB6 Tri-Break 49.75 15.50 10.75
150A TE & TB1 17.75 9.75 6.75

Meter Mod III PTO Section (Fig. 3)


Dimensions (Inches)
Product Number/Frame W H D
Bused Main Breakers
TMP3BR4/TJK4 19 18 5.94
TMP3BL6/TJK6 19 18 5.94
TMP3BR6/TJK6 19 18 5.94
Fig. 1 Bolt on, Flex-A-Tap Fig. 2 Flatwise PTO Section TMP3BL8/TKM8 20 18 7.88
TMP3BR8/TKM8 20 18 7.88
TMP3BL10/TKM10 20 18 7.88
TMP3BR10/TKM10 20 18 7.88
TMP3BL12/TKM12 20 18 7.88
TMP3BR12/TKM12 20 18 7.88
Bused Main Switches
TMP3FL4/TFUSE400 19 18 5.94
TMP3FR4/TFUSE400 19 18 5.94
TMP3FL6/TFUSE600 19 18 5.94
TMP3FR6/TFUSE600 19 18 5.94
Fig. 3 Meter Mod III PTO Section
available with no device. Check local codes before ordering Amps Bar Per Bar Width (inches) "A" (inches)
1.625
2.225

225-1200 Al 2.875
16.50
225-1600 Cu 3.375
1 4.250
4.500
5.750
1350-2000 Al 6.500 20.00
2000-2500 Cu
8.250

2500 Al 4.250
24.75
3000 Cu 4.500
Fig. 4 Meter-mod Metering (in line device)
2 5.750
Available for G&K Frame Spectra C/B only 3000-4000 Al 6.500 32.00
4000-5000 Cu
8.250
Flex-A-Tap Device (Fig. 1)
Decimal Fraction
Device "H " " W" "D "
.12 1/8
Cable Tap Box 54" 24" 15 1/2"
.38 3/8
KM 66" 19 9/32" 15 1/2"
.63 5/8
QMW 600A 66" 19 9/32" 15 1/2"
.88 7/8
Power Break II 63" 24 9/32" 18"
1TMZR mounting Z-rail must be added for the attached Meter Mod.

Rev. 11/13 www.geindustrial.com BuyLog Catalog 13-43


Data subject to change
without notice
Busway Section 13
Spectra Series Busway
LowAmp
Application and Product Numbers

Features/Benefits Available Ratings


Amperes: 225 to 800 amperes
Easy Install:
Voltage: 600 Volts or less
New Joint-Guard Protection Systemdynamically indicates Busing: Aluminum or Copper
proper torque through color! Easy install and maintenance! Systems: 3-phase, 3-wire and 3-phase, 4-wire (full neutral)
Enclosures: Indoor, drip-proof, (totally enclosed)
Lighter Weightmeans it installs faster than other busways and
beats wire and conduit for total installed cost.
Single Drop-Rod Hangeris furnished with straight lengths for Spectra Series LowAmp Busway Pricing
easy, fast installation.
Product number pricing
Field-Adjustable Isolation Joint( 5/8 per joint) provides on-
Use the product numbers from tables, or parametric product
site flexibility.
number generation, on pages 13-45 through 13-57 to select
Adjustable Straight Lengthcan eliminate the need for field
busway components individually. One standard flatwise clevis-
check pieces! (6 from nominal 54).
type hanger is provided with every straight length. Optional
hangers are available and should be ordered separately.
Performance/Protection/Maintenance:
Exclusive BlueCoat Epoxy Insulation(Class B, UL 130C) pro- LowAmp Dripproof Busway is available. Contact the factory for
vides the industrys best protection (50 years). pricing.
Earth-Bond Integrated Grounding Systemprovides a lower
resistance ground path than internal ground bars.
IP4X Plug OutletGEs exclusive plug outlet provides the indus-
trys highest protection. Its dead front is fingerproof and screw-
driver-proof. (Also meets IP2X and IP3X.)
Belleville Spring Washerthe industrys best, retains over 90%
of original contact pressure, offering a maintenance-free joint
when torqued properly.

13-44 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Busway Section 13
Spectra Series Busway (continued)
LowAmp
Application and Product Numbers

Spectra Series LowAmp Busway Product Numbering System

L F 3 H C 02 SL 02 B
Type Code
Description Code Indoor Blank
Product
Spectra Series Low/Amp L Transverse Barrier3 B
Feeder F
Type
Plug-In4 P
3PH, 3W 3 Type Feet Code
Service
3PH, 4W 100% Neutral 4 2 02
Integrated Housing H 3 03
Ground Feeder
Internal Bus1 G 5 05
Copper C Amp Code 10 10
Conductor
Aluminum A 225 02 4 04
400 04 Plug-In 6 06
Configurations Code 600 06 10 10
Straight Length SL 800 08 Fittings NA ST
ElbowLeft EL Off Sets:
ElbowRight ER Configurations Code 6" 06
ElbowUp EU Busway Adapter 12" 12
ElbowDown ED Spectra Bus SB 18" 18
Center Cable Tap BoxUp CT Armor-Clad Style 3 Blot End BE
Center Cable Tap BoxDown CB Armor-Clad Style 3 Slot End SE
End Cable Tap BoxUp TT Busway Stubs (600-800)2,3
End Cable Tap BoxDown TB Spectra/AV-Line Switchboard SA
End Box EB AKD8/Power Break AK
Flanged End FE MCC 8000 Line MC
Flanged End w/Lugs FL Panelboards PA
Adjustable StraightLength AS
Expansion LengthUp XU
Expansion LengthDown XD
Total Phase Transposition TF
TeeRight TR
TeeLeft TL
TeeUp TU
TeeDown TD
Off SetUp OU
Off SetDown OD
Off SetRight OR
Off SetLeft OL
1 Available w/copper bus bars only.
2 Requires drawing for layout configuration.
3 Item available in feeder construction only. (Use with fire barrier and wall/floor flange for 3-hour fire rating)
4 Straight lengths only.

Rev. 11/13 www.geindustrial.com BuyLog Catalog 13-45


Data subject to change
without notice
Busway Section 13
Spectra Series Busway
LowAmp
Aluminum Conductors

225 Amps Three-Phase, Three-Wire 400 Amps Three-Phase, Three-Wire


Integrated Housing Ground Integrated Housing Ground
Component Type Product Number Component Type Product Number
Linear Lengths Plug-In: 10-ft. LP3HA02SL10 Linear Lengths Plug-In: 10-ft. LP3HA04SL10
Linear Lengths Plug-In: 6-ft. LP3HA02SL06 Linear Lengths Plug-In: 6-ft. LP3HA04SL06
Linear Lengths Plug-In: 4-ft. LP3HA02SL04 Linear Lengths Plug-In: 4-ft. LP3HA04SL04
Linear Lengths Feeder: 10-ft. LF3HA02SL10 Linear Lengths Feeder: 10-ft. LF3HA04SL10
Linear Lengths Feeder: 5-ft. LF3HA02SL05 Linear Lengths Feeder: 5-ft. LF3HA04SL05
Linear Lengths Feeder: 3-ft. LF3HA02SL03 Linear Lengths Feeder: 3-ft. LF3HA04SL03
Linear Lengths Feeder: 2-ft. LF3HA02SL02 Linear Lengths Feeder: 2-ft. LF3HA04SL02
Linear Lengths Adjustable Straight Length LF3HA02ASST Linear Lengths Adjustable Straight Length LF3HA04ASST
Fittings Elbow Left 90 LF3HA02ELST Fittings Elbow Left 90 LF3HA04ELST
Fittings Elbow Right 90 LF3HA02ERST Fittings Elbow Right 90 LF3HA04ERST
Fittings Elbow Up 90 LF3HA02EUST Fittings Elbow Up 90 LF3HA04EUST
Fittings Elbow Down 90 LF3HA02EDST Fittings Elbow Down 90 LF3HA04EDST
Accessories End Cable Tap BoxUp LF3HA02TTST Accessories End Cable Tap BoxUp LF3HA04TTST
Accessories End Cable Tap BoxDown LF3HA02TBST Accessories End Cable Tap BoxDown LF3HA04TBST
Accessories Center Cable Tap BoxUp LF3HA02CTST Accessories Center Cable Tap BoxUp LF3HA04CTST
Accessories Center Cable Tap BoxDown LF3HA02CBST Accessories Center Cable Tap BoxDown LF3HA04CBST
Accessories End Box LF3HA02EBST Accessories End Box LF3HA04EBST
Accessories Flanged End w/Lugs LF3HA02FLST Accessories Flanged End w/Lugs LF3HA04FLST
Accessories Flanged End LF3HA02FEST Accessories Flanged End LF3HA04FEST
Fittings Expansion LengthUp LF3HA02XUST Fittings Expansion LengthUp LF3HA04XUST
Fittings Expansion LengthDown LF3HA02XDST Fittings Expansion LengthDown LF3HA04XDST
Fittings Total Phase Transposition LF3HA02TFST Fittings Total Phase Transposition LF3HA04TFST
Fittings TeeRight LF3HA02TRST Fittings TeeRight LF3HA04TRST
Fittings TeeLeft LF3HA02TLST Fittings TeeLeft LF3HA04TLST
Fittings TeeUp LF3HA02TUST Fittings TeeUp LF3HA04TUST
Fittings TeeDown LF3HA02TDST Fittings TeeDown LF3HA04TDST
Fittings Off SetUp (6) LF3HA02OU06 Fittings Off SetUp (6) LF3HA04OU06
Fittings Off SetUp (12) LF3HA02OU12 Fittings Off SetUp (12) LF3HA04OU12
Fittings Off SetUp (18) LF3HA02OU18 Fittings Off SetUp (18) LF3HA04OU18
Fittings Off SetDown (6) LF3HA02OD06 Fittings Off SetDown (6) LF3HA04OD06
Fittings Off SetDown (12) LF3HA02OD12 Fittings Off SetDown (12) LF3HA04OD12
Fittings Off SetDown (18) LF3HA02OD18 Fittings Off SetDown (18) LF3HA04OD18
Fittings Off SetLeft (6) LF3HA02OL06 Fittings Off SetLeft (6) LF3HA04OL06
Fittings Off SetLeft (12) LF3HA02OL12 Fittings Off SetLeft (12) LF3HA04OL12
Fittings Off SetLeft (18) LF3HA02OL18 Fittings Off SetLeft (18) LF3HA04OL18
Fittings Off SetRight (6) LF3HA02OR06 Fittings Off SetRight (6) LF3HA04OR06
Fittings Off SetRight (12) LF3HA02OR12 Fittings Off SetRight (12) LF3HA04OR12
Fittings Off Set Right (18) LF3HA02OR18 Fittings Off Set Right (18) LF3HA04OR18

Hangers - Common to all Service


Amperage Accessory Type Product Number
800 Amps Hanger-EdgewiseTrapeze SLTE2
800 Amps Hanger-FlatwiseTrapeze SLTF2
800 Amps Hanger-EdgewiseClevis SLEC2
225 Amps Hanger-FlatwiseClevis SLFC21
400 Amps Hanger-FlatwiseClevis SLFC31
600 Amps Hanger-FlatwiseClevis SLFC41
800 Amps Hanger-FlatwiseClevis SLFC51
400 Amps Hanger-Spring Riser SLSR2
600 Amps Hanger-Spring Riser SLSR4
800 Amps Hanger-Spring Riser SLSR5
225 Amps Hanger-Wall/Floor Flange SLWF2
400 Amps Hanger-Wall/Floor Flange SLWF3
600 Amps Hanger-Wall/Floor Flange SLWF4
800 Amps Hanger-Wall/Floor Flange SLWF5
800 Amps Hanger-Outlet Covers SLOC2
1Standard hanger provided unless otherwise specified.

13-46 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Busway Section 13
Spectra Series Busway (continued)
LowAmp
Aluminum Conductors

600 Amps Three-Phase, Three-Wire 800 Amps Three-Phase, Three-Wire


Integrated Housing Ground Integrated Housing Ground
Component Type Product Number Component Type Product Number
Linear Lengths Plug-In: 10-ft. LP3HA06SL10 Linear Lengths Plug-In: 10-ft. LP3HA08SL10
Linear Lengths Plug-In: 6-ft. LP3HA06SL06 Linear Lengths Plug-In: 6-ft. LP3HA08SL06
Linear Lengths Plug-In: 4-ft. LP3HA06SL04 Linear Lengths Plug-In: 4-ft. LP3HA08SL04
Linear Lengths Feeder: 10-ft. LF3HA06SL10 Linear Lengths Feeder: 10-ft. LF3HA08SL10
Linear Lengths Feeder: 5-ft. LF3HA06SL05 Linear Lengths Feeder: 5-ft. LF3HA08SL05
Linear Lengths Feeder: 3-ft. LF3HA06SL03 Linear Lengths Feeder: 3-ft. LF3HA08SL03
Linear Lengths Feeder: 2-ft. LF3HA06SL02 Linear Lengths Feeder: 2-ft. LF3HA08SL02
Linear Lengths Adjustable Straight Length LF3HA06ASST Linear Lengths Adjustable Straight Length LF3HA08ASST
Fittings Elbow Left 90 LF3HA06ELST Fittings Elbow Left 90 LF3HA08ELST
Fittings Elbow Right 90 LF3HA06ERST Fittings Elbow Right 90 LF3HA08ERST
Fittings Elbow Up 90 LF3HA06EUST Fittings Elbow Up 90 LF3HA08EUST
Fittings Elbow Down 90 LF3HA06EDST Fittings Elbow Down 90 LF3HA08EDST
Accessories End Cable Tap BoxUp LF3HA06TTST Accessories End Cable Tap BoxUp LF3HA08TTST
Accessories End Cable Tap BoxDown LF3HA06TBST Accessories End Cable Tap BoxDown LF3HA08TBST
Accessories Center Cable Tap BoxUp LF3HA06CTST Accessories Center Cable Tap BoxUp LF3HA08CTST
Accessories Center Cable Tap BoxDown LF3HA06CBST Accessories Center Cable Tap BoxDown LF3HA08CBST
Accessories End Box LF3HA06EBST Accessories End Box LF3HA08EBST
Accessories Flanged End w/Lugs LF3HA06FLST Accessories Flanged End w/Lugs LF3HA08FLST
Accessories Flanged End LF3HA06FEST Accessories Flanged End LF3HA08FEST
Fittings Expansion LengthUp LF3HA06XUST Fittings Expansion LengthUp LF3HA08XUST
Fittings Expansion LengthDown LF3HA06XDST Fittings Expansion LengthDown LF3HA08XDST
Fittings Total Phase Transposition LF3HA06TFST Fittings Total Phase Transposition LF3HA08TFST
Fittings TeeRight LF3HA06TRST Fittings TeeRight LF3HA08TRST
Fittings TeeLeft LF3HA06TLST Fittings TeeLeft LF3HA08TLST
Fittings TeeUp LF3HA06TUST Fittings TeeUp LF3HA08TUST
Fittings TeeDown LF3HA06TDST Fittings TeeDown LF3HA08TDST
Fittings Off SetUp (6) LF3HA06OU06 Fittings Off SetUp (6) LF3HA08OU06
Fittings Off SetUp (12) LF3HA06OU12 Fittings Off SetUp (12) LF3HA08OU12
Fittings Off SetUp (18) LF3HA06OU18 Fittings Off SetUp (18) LF3HA08OU18
Fittings Off SetDown (6) LF3HA06OD06 Fittings Off SetDown (6) LF3HA08OD06
Fittings Off SetDown (12) LF3HA06OD12 Fittings Off SetDown (12) LF3HA08OD12
Fittings Off SetDown (18) LF3HA06OD18 Fittings Off SetDown (18) LF3HA08OD18
Fittings Off SetLeft (6) LF3HA06OL06 Fittings Off SetLeft (6) LF3HA08OL06
Fittings Off SetLeft (12) LF3HA06OL12 Fittings Off SetLeft (12) LF3HA08OL12
Fittings Off SetLeft (18) LF3HA06OL18 Fittings Off SetLeft (18) LF3HA08OL18
Fittings Off SetRight (6) LF3HA06OR06 Fittings Off SetRight (6) LF3HA08OR06
Fittings Off SetRight (12) LF3HA06OR12 Fittings Off SetRight (12) LF3HA08OR12
Fittings Off Set Right (18) LF3HA06OR18 Fittings Off Set Right (18) LF3HA08OR18

Hangers - Common to all Services


Amperage Accessory Type Product Number
800 Amps Hanger-EdgewiseTrapeze SLTE2
800 Amps Hanger-FlatwiseTrapeze SLTF2
800 Amps Hanger-EdgewiseClevis SLEC2
225 Amps Hanger-FlatwiseClevis SLFC21
400 Amps Hanger-FlatwiseClevis SLFC31
600 Amps Hanger-FlatwiseClevis SLFC41
800 Amps Hanger-FlatwiseClevis SLFC51
400 Amps Hanger-Spring Riser SLSR2
600 Amps Hanger-Spring Riser SLSR4
800 Amps Hanger-Spring Riser SLSR5
225 Amps Hanger-Wall/Floor Flange SLWF2
400 Amps Hanger-Wall/Floor Flange SLWF3
600 Amps Hanger-Wall/Floor Flange SLWF4
800 Amps Hanger-Wall/Floor Flange SLWF5
800 Amps Hanger-Outlet Covers SLOC2
1Standard hanger provided unless otherwise specified.

Rev. 11/13 www.geindustrial.com BuyLog Catalog 13-47


Data subject to change
without notice
Busway Section 13
Spectra Series Busway
LowAmp
Aluminum Conductors

225 Amps Three-Phase, Four-Wire Integrated Housing Ground 400 Amps Three-Phase, Four-Wire Integrated Housing Ground
Component Type Product Number Component Type Product Number
Linear Lengths Plug-In: 10-ft. LP4HA02SL10 Linear Lengths Plug-In: 10-ft. LP4HA04SL10
Linear Lengths Plug-In: 6-ft. LP4HA02SL06 Linear Lengths Plug-In: 6-ft. LP4HA04SL06
Linear Lengths Plug-In: 4-ft. LP4HA02SL04 Linear Lengths Plug-In: 4-ft. LP4HA04SL04
Linear Lengths Feeder: 10-ft. LF4HA02SL10 Linear Lengths Feeder: 10-ft. LF4HA04SL10
Linear Lengths Feeder: 5-ft. LF4HA02SL05 Linear Lengths Feeder: 5-ft. LF4HA04SL05
Linear Lengths Feeder: 3-ft. LF4HA02SL03 Linear Lengths Feeder: 3-ft. LF4HA04SL03
Linear Lengths Feeder: 2-ft. LF4HA02SL02 Linear Lengths Feeder: 2-ft. LF4HA04SL02
Linear Lengths Adjustable Straight Length LF4HA02ASST Linear Lengths Adjustable Straight Length LF4HA04ASST
Fittings Elbow Left 90 LF4HA02ELST Fittings Elbow Left 90 LF4HA04ELST
Fittings Elbow Right 90 LF4HA02ERST Fittings Elbow Right 90 LF4HA04ERST
Fittings Elbow Up 90 LF4HA02EUST Fittings Elbow Up 90 LF4HA04EUST
Fittings Elbow Down 90 LF4HA02EDST Fittings Elbow Down 90 LF4HA04EDST
Accessories End Cable Tap BoxUp LF4HA02TTST Accessories End Cable Tap BoxUp LF4HA04TTST
Accessories End Cable Tap BoxDown LF4HA02TBST Accessories End Cable Tap BoxDown LF4HA04TBST
Accessories Center Cable Tap BoxUp LF4HA02CTST Accessories Center Cable Tap BoxUp LF4HA04CTST
Accessories Center Cable Tap BoxDown LF4HA02CBST Accessories Center Cable Tap BoxDown LF4HA04CBST
Accessories End Box LF4HA02EBST Accessories End Box LF4HA04EBST
Accessories Flanged End w/Lugs LF4HA02FLST Accessories Flanged End w/Lugs LF4HA04FLST
Accessories Flanged End LF4HA02FEST Accessories Flanged End LF4HA04FEST
Fittings Expansion LengthUp LF4HA02XUST Fittings Expansion LengthUp LF4HA04XUST
Fittings Expansion LengthDown LF4HA02XDST Fittings Expansion LengthDown LF4HA04XDST
Fittings Total Phase Transposition LF4HA02TFST Fittings Total Phase Transposition LF4HA04TFST
Fittings TeeRight LF4HA02TRST Fittings TeeRight LF4HA04TRST
Fittings TeeLeft LF4HA02TLST Fittings TeeLeft LF4HA04TLST
Fittings TeeUp LF4HA02TUST Fittings TeeUp LF4HA04TUST
Fittings TeeDown LF4HA02TDST Fittings TeeDown LF4HA04TDST
Fittings Off SetUp (6) LF4HA02OU06 Fittings Off SetUp (6) LF4HA04OU06
Fittings Off SetUp (12) LF4HA02OU12 Fittings Off SetUp (12) LF4HA04OU12
Fittings Off SetUp (18) LF4HA02OU18 Fittings Off SetUp (18) LF4HA04OU18
Fittings Off SetDown (6) LF4HA02OD06 Fittings Off SetDown (6) LF4HA04OD06
Fittings Off SetDown (12) LF4HA02OD12 Fittings Off SetDown (12) LF4HA04OD12
Fittings Off SetDown (18) LF4HA02OD18 Fittings Off SetDown (18) LF4HA04OD18
Fittings Off SetLeft (6) LF4HA02OL06 Fittings Off SetLeft (6) LF4HA04OL06
Fittings Off SetLeft (12) LF4HA02OL12 Fittings Off SetLeft (12) LF4HA04OL12
Fittings Off SetLeft (18) LF4HA02OL18 Fittings Off SetLeft (18) LF4HA04OL18
Fittings Off SetRight (6) LF4HA02OR06 Fittings Off SetRight (6) LF4HA04OR06
Fittings Off SetRight (12) LF4HA02OR12 Fittings Off SetRight (12) LF4HA04OR12
Fittings Off Set Right (18) LF4HA02OR18 Fittings Off Set Right (18) LF4HA04OR18

Hangers - Common to all Services


Amperage Accessory Type Product Number
800 Amps Hanger-EdgewiseTrapeze SLTE2
800 Amps Hanger-FlatwiseTrapeze SLTF2
800 Amps Hanger-EdgewiseClevis SLEC2
225 Amps Hanger-FlatwiseClevis SLFC21
400 Amps Hanger-FlatwiseClevis SLFC31
600 Amps Hanger-FlatwiseClevis SLFC41
800 Amps Hanger-FlatwiseClevis SLFC51
400 Amps Hanger-Spring Riser SLSR2
600 Amps Hanger-Spring Riser SLSR4
800 Amps Hanger-Spring Riser SLSR5
225 Amps Hanger-Wall/Floor Flange SLWF2
400 Amps Hanger-Wall/Floor Flange SLWF3
600 Amps Hanger-Wall/Floor Flange SLWF4
800 Amps Hanger-Wall/Floor Flange SLWF5
800 Amps Hanger-Outlet Covers SLOC2
1Standard hanger provided unless otherwise specified.

13-48 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Busway Section 13
Spectra Series Busway (continued)
LowAmp
Aluminum Conductors

600 Amps Three-Phase, Four-Wire Integrated Housing Ground 800 Amps Three-Phase, Four-Wire Integrated Housing Ground
Component Type Product Number Component Type Product Number
Linear Lengths Plug-In: 10-ft. LP4HA06SL10 Linear Lengths Plug-In: 10-ft. LP4HA08SL10
Linear Lengths Plug-In: 6-ft. LP4HA06SL06 Linear Lengths Plug-In: 6-ft. LP4HA08SL06
Linear Lengths Plug-In: 4-ft. LP4HA06SL04 Linear Lengths Plug-In: 4-ft. LP4HA08SL04
Linear Lengths Feeder: 10-ft. LF4HA06SL10 Linear Lengths Feeder: 10-ft. LF4HA08SL10
Linear Lengths Feeder: 5-ft. LF4HA06SL05 Linear Lengths Feeder: 5-ft. LF4HA08SL05
Linear Lengths Feeder: 3-ft. LF4HA06SL03 Linear Lengths Feeder: 3-ft. LF4HA08SL03
Linear Lengths Feeder: 2-ft. LF4HA06SL02 Linear Lengths Feeder: 2-ft. LF4HA08SL02
Linear Lengths Adjustable Straight Length LF4HA06ASST Linear Lengths Adjustable Straight Length LF4HA08ASST
Fittings Elbow Left 90 LF4HA06ELST Fittings Elbow Left 90 LF4HA08ELST
Fittings Elbow Right 90 LF4HA06ERST Fittings Elbow Right 90 LF4HA08ERST
Fittings Elbow Up 90 LF4HA06EUST Fittings Elbow Up 90 LF4HA08EUST
Fittings Elbow Down 90 LF4HA06EDST Fittings Elbow Down 90 LF4HA08EDST
Accessories End Cable Tap BoxUp LF4HA06TTST Accessories End Cable Tap BoxUp LF4HA08TTST
Accessories End Cable Tap BoxDown LF4HA06TBST Accessories End Cable Tap BoxDown LF4HA08TBST
Accessories Center Cable Tap BoxUp LF4HA06CTST Accessories Center Cable Tap BoxUp LF4HA08CTS
Accessories Center Cable Tap BoxDown LF4HA06CBST Accessories Center Cable Tap BoxDown LF4HA08CBST
Accessories End Box LF4HA06EBST Accessories End Box LF4HA08EBST
Accessories Flanged End w/Lugs LF4HA06FLST Accessories Flanged End w/Lugs LF4HA08FLST
Accessories Flanged End LF4HA06FEST Accessories Flanged End LF4HA08FEST
Fittings Expansion LengthUp LF4HA06XUST Fittings Expansion LengthUp LF4HA08XUST
Fittings Expansion LengthDown LF4HA06XDST Fittings Expansion LengthDown LF4HA08XDST
Fittings Total Phase Transposition LF4HA06TFST Fittings Total Phase Transposition LF4HA08TFST
Fittings TeeRight LF4HA06TRST Fittings TeeRight LF4HA08TRST
Fittings TeeLeft LF4HA06TLST Fittings TeeLeft LF4HA08TLST
Fittings TeeUp LF4HA06TUST Fittings TeeUp LF4HA08TUST
Fittings TeeDown LF4HA06TDST Fittings TeeDown LF4HA08TDST
Fittings Off SetUp (6) LF4HA06OU06 Fittings Off SetUp (6) LF4HA08OU06
Fittings Off SetUp (12) LF4HA06OU12 Fittings Off SetUp (12) LF4HA08OU12
Fittings Off SetUp (18) LF4HA06OU18 Fittings Off SetUp (18) LF4HA08OU18
Fittings Off SetDown (6) LF4HA06OD06 Fittings Off SetDown (6) LF4HA08OD06
Fittings Off SetDown (12) LF4HA06OD12 Fittings Off SetDown (12) LF4HA08OD12
Fittings Off SetDown (18) LF4HA06OD18 Fittings Off SetDown (18) LF4HA08OD18
Fittings Off SetLeft (6) LF4HA06OL06 Fittings Off SetLeft (6) LF4HA08OL06
Fittings Off SetLeft (12) LF4HA06OL12 Fittings Off SetLeft (12) LF4HA08OL12
Fittings Off SetLeft (18) LF4HA06OL18 Fittings Off SetLeft (18) LF4HA08OL18
Fittings Off SetRight (6) LF4HA06OR06 Fittings Off SetRight (6) LF4HA08OR06
Fittings Off SetRight (12) LF4HA06OR12 Fittings Off SetRight (12) LF4HA08OR12
Fittings Off Set Right (18) LF4HA06OR18 Fittings Off Set Right (18) LF4HA08OR18

Hangers - Common to all Services


Amperage Accessory Type Product Number
800 Amps Hanger-EdgewiseTrapeze SLTE2
800 Amps Hanger-FlatwiseTrapeze SLTF2
800 Amps Hanger-EdgewiseClevis SLEC2
225 Amps Hanger-FlatwiseClevis SLFC21
400 Amps Hanger-FlatwiseClevis SLFC31
600 Amps Hanger-FlatwiseClevis SLFC41
800 Amps Hanger-FlatwiseClevis SLFC51
400 Amps Hanger-Spring Riser SLSR2
600 Amps Hanger-Spring Riser SLSR4
800 Amps Hanger-Spring Riser SLSR5
225 Amps Hanger-Wall/Floor Flange SLWF2
400 Amps Hanger-Wall/Floor Flange SLWF3
600 Amps Hanger-Wall/Floor Flange SLWF4
800 Amps Hanger-Wall/Floor Flange SLWF5
800 Amps Hanger-Outlet Covers SLOC2
1Standard hanger provided unless otherwise specified.

Rev. 11/13 www.geindustrial.com BuyLog Catalog 13-49


Data subject to change
without notice
Busway Section 13
Spectra Series Busway
LowAmp
Copper Conductors

225 Amps Three-Phase, Three-Wire Integrated Housing Ground 400 Amps Three-Phase, Three-Wire Integrated Housing Ground
Component Type Product Number Component Type Product Number
Linear Lengths Plug-In: 10-ft. LP3HC02SL10 Linear Lengths Plug-In: 10-ft. LP3HC04SL10
Linear Lengths Plug-In: 6-ft. LP3HC02SL06 Linear Lengths Plug-In: 6-ft. LP3HC04SL06
Linear Lengths Plug-In: 4-ft. LP3HC02SL04 Linear Lengths Plug-In: 4-ft. LP3HC04SL04
Linear Lengths Feeder: 10-ft. LF3HC02SL10 Linear Lengths Feeder: 10-ft. LF3HC04SL10
Linear Lengths Feeder: 5-ft. LF3HC02SL05 Linear Lengths Feeder: 5-ft. LF3HC04SL05
Linear Lengths Feeder: 3-ft. LF3HC02SL03 Linear Lengths Feeder: 3-ft. LF3HC04SL03
Linear Lengths Feeder: 2-ft. LF3HC02SL02 Linear Lengths Feeder: 2-ft. LF3HC04SL02
Linear Lengths Adjustable Straight Length LF3HC02ASST Linear Lengths Adjustable Straight Length LF3HC04ASST
Fittings Elbow Left 90 LF3HC02ELST Fittings Elbow Left 90 LF3HC04ELST
Fittings Elbow Right 90 LF3HC02ERST Fittings Elbow Right 90 LF3HC04ERST
Fittings Elbow Up 90 LF3HC02EUST Fittings Elbow Up 90 LF3HC04EUST
Fittings Elbow Down 90 LF3HC02EDST Fittings Elbow Down 90 LF3HC04EDST
Accessories End Cable Tap BoxUp LF3HC02TTST Accessories End Cable Tap BoxUp LF3HC04TTST
Accessories End Cable Tap BoxDown LF3HC02TBST Accessories End Cable Tap BoxDown LF3HC04TBST
Accessories Center Cable Tap BoxUp LF3HC02CTST Accessories Center Cable Tap BoxUp LF3HC04CTST
Accessories Center Cable Tap BoxDown LF3HC02CBST Accessories Center Cable Tap BoxDown LF3HC04CBST
Accessories End Box LF3HC02EBST Accessories End Box LF3HC04EBST
Accessories Flanged End w/Lugs LF3HC02FLST Accessories Flanged End w/Lugs LF3HC04FLST
Accessories Flanged End LF3HC02FEST Accessories Flanged End LF3HC04FEST
Fittings Expansion LengthUp LF3HC02XUST Fittings Expansion LengthUp LF3HC04XUST
Fittings Expansion LengthDown LF3HC02XDST Fittings Expansion LengthDown LF3HC04XDST
Fittings Total Phase Transposition LF3HC02TFST Fittings Total Phase Transposition LF3HC04TFST
Fittings TeeRight LF3HC02TRST Fittings TeeRight LF3HC04TRST
Fittings TeeLeft LF3HC02TLST Fittings TeeLeft LF3HC04TLST
Fittings TeeUp LF3HC02TUST Fittings TeeUp LF3HC04TUST
Fittings TeeDown LF3HC02TDST Fittings TeeDown LF3HC04TDST
Fittings Off SetUp (6) LF3HC02OU06 Fittings Off SetUp (6) LF3HC04OU06
Fittings Off SetUp (12) LF3HC02OU12 Fittings Off SetUp (12) LF3HC04OU12
Fittings Off SetUp (18) LF3HC02OU18 Fittings Off SetUp (18) LF3HC04OU18
Fittings Off SetDown (6) LF3HC02OD06 Fittings Off SetDown (6) LF3HC04OD06
Fittings Off SetDown (12) LF3HC02OD12 Fittings Off SetDown (12) LF3HC04OD12
Fittings Off SetDown (18) LF3HC02OD18 Fittings Off SetDown (18) LF3HC04OD18
Fittings Off SetLeft (6) LF3HC02OL06 Fittings Off SetLeft (6) LF3HC04OL06
Fittings Off SetLeft (12) LF3HC02OL12 Fittings Off SetLeft (12) LF3HC04OL12
Fittings Off SetLeft (18) LF3HC02OL18 Fittings Off SetLeft (18) LF3HC04OL18
Fittings Off SetRight (6) LF3HC02OR06 Fittings Off SetRight (6) LF3HC04OR06
Fittings Off SetRight (12) LF3HC02OR12 Fittings Off SetRight (12) LF3HC04OR12
Fittings Off Set Right (18) LF3HC02OR18 Fittings Off Set Right (18) LF3HC04OR18

Hangers - Common to all Services


Amperage Accessory Type Product Number
800 Amps Hanger-EdgewiseTrapeze SLTE2
800 Amps Hanger-FlatwiseTrapeze SLTF2
800 Amps Hanger-EdgewiseClevis SLEC2
225 Amps Hanger-FlatwiseClevis SLFC21
400 Amps Hanger-FlatwiseClevis SLFC31
600 Amps Hanger-FlatwiseClevis SLFC41
800 Amps Hanger-FlatwiseClevis SLFC51
400 Amps Hanger-Spring Riser SLSR2
600 Amps Hanger-Spring Riser SLSR4
800 Amps Hanger-Spring Riser SLSR5
225 Amps Hanger-Wall/Floor Flange SLWF2
400 Amps Hanger-Wall/Floor Flange SLWF3
600 Amps Hanger-Wall/Floor Flange SLWF4
800 Amps Hanger-Wall/Floor Flange SLWF5
800 Amps Hanger-Outlet Covers SLOC2
1Standard hanger provided unless otherwise specified.

13-50 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Busway Section 13
Spectra Series Busway (continued)
LowAmp
Copper Conductors

600 Amps Three-Phase, Three-Wire Integrated Housing Ground 800 Amps Three-Phase, Three-Wire Integrated Housing Ground
Component Type Product Number Component Type Product Number
Linear Lengths Plug-In: 10-ft. LP3HC06SL10 Linear Lengths Plug-In: 10-ft. LP3HC08SL10
Linear Lengths Plug-In: 6-ft. LP3HC06SL06 Linear Lengths Plug-In: 6-ft. LP3HC08SL06
Linear Lengths Plug-In: 4-ft. LP3HC06SL04 Linear Lengths Plug-In: 4-ft. LP3HC08SL04
Linear Lengths Feeder: 10-ft. LF3HC06SL10 Linear Lengths Feeder: 10-ft. LF3HC08SL10
Linear Lengths Feeder: 5-ft. LF3HC06SL05 Linear Lengths Feeder: 5-ft. LF3HC08SL05
Linear Lengths Feeder: 3-ft. LF3HC06SL03 Linear Lengths Feeder: 3-ft. LF3HC08SL03
Linear Lengths Feeder: 2-ft. LF3HC06SL02 Linear Lengths Feeder: 2-ft. LF3HC08SL02
Linear Lengths Adjustable Straight Length LF3HC06ASST Linear Lengths Adjustable Straight Length LF3HC08ASST
Fittings Elbow Left 90 LF3HC06ELST Fittings Elbow Left 90 LF3HC08ELST
Fittings Elbow Right 90 LF3HC06ERST Fittings Elbow Right 90 LF3HC08ERST
Fittings Elbow Up 90 LF3HC06EUST Fittings Elbow Up 90 LF3HC08EUST
Fittings Elbow Down 90 LF3HC06EDST Fittings Elbow Down 90 LF3HC08EDST
Accessories End Cable Tap BoxUp LF3HC06TTST Accessories End Cable Tap BoxUp LF3HC08TTST
Accessories End Cable Tap BoxDown LF3HC06TBST Accessories End Cable Tap BoxDown LF3HC08TBST
Accessories Center Cable Tap BoxUp LF3HC06CTST Accessories Center Cable Tap BoxUp LF3HC08CTST
Accessories Center Cable Tap BoxDown LF3HC06CBST Accessories Center Cable Tap BoxDown LF3HC08CBST
Accessories End Box LF3HC06EBST Accessories End Box LF3HC08EBST
Accessories Flanged End w/Lugs LF3HC06FLST Accessories Flanged End w/Lugs LF3HC08FLST
Accessories Flanged End LF3HC06FEST Accessories Flanged End LF3HC08FEST
Fittings Expansion LengthUp LF3HC06XUST Fittings Expansion LengthUp LF3HC08XUST
Fittings Expansion LengthDown LF3HC06XDST Fittings Expansion LengthDown LF3HC08XDST
Fittings Total Phase Transposition LF3HC06TFST Fittings Total Phase Transposition LF3HC08TFST
Fittings TeeRight LF3HC06TRST Fittings TeeRight LF3HC08TRST
Fittings TeeLeft LF3HC06TLST Fittings TeeLeft LF3HC08TLST
Fittings TeeUp LF3HC06TUST Fittings TeeUp LF3HC08TUST
Fittings TeeDown LF3HC06TDST Fittings TeeDown LF3HC08TDST
Fittings Off SetUp (6) LF3HC06OU06 Fittings Off SetUp (6) LF3HC08OU06
Fittings Off SetUp (12) LF3HC06OU12 Fittings Off SetUp (12) LF3HC08OU12
Fittings Off SetUp (18) LF3HC06OU18 Fittings Off SetUp (18) LF3HC08OU18
Fittings Off SetDown (6) LF3HC06OD06 Fittings Off SetDown (6) LF3HC08OD06
Fittings Off SetDown (12) LF3HC06OD12 Fittings Off SetDown (12) LF3HC08OD12
Fittings Off SetDown (18) LF3HC06OD18 Fittings Off SetDown (18) LF3HC08OD18
Fittings Off SetLeft (6) LF3HC06OL06 Fittings Off SetLeft (6) LF3HC08OL06
Fittings Off SetLeft (12) LF3HC06OL12 Fittings Off SetLeft (12) LF3HC08OL12
Fittings Off SetLeft (18) LF3HC06OL18 Fittings Off SetLeft (18) LF3HC08OL18
Fittings Off SetRight (6) LF3HC06OR06 Fittings Off SetRight (6) LF3HC08OR06
Fittings Off SetRight (12) LF3HC06OR12 Fittings Off SetRight (12) LF3HC08OR12
Fittings Off Set Right (18) LF3HC06OR18 Fittings Off Set Right (18) LF3HC08OR18

Hangers - Common to all Services


Amperage Accessory Type Product Number
800 Amps Hanger-EdgewiseTrapeze SLTE2
800 Amps Hanger-FlatwiseTrapeze SLTF2
800 Amps Hanger-EdgewiseClevis SLEC2
225 Amps Hanger-FlatwiseClevis SLFC21
400 Amps Hanger-FlatwiseClevis SLFC31
600 Amps Hanger-FlatwiseClevis SLFC41
800 Amps Hanger-FlatwiseClevis SLFC51
400 Amps Hanger-Spring Riser SLSR2
600 Amps Hanger-Spring Riser SLSR4
800 Amps Hanger-Spring Riser SLSR5
225 Amps Hanger-Wall/Floor Flange SLWF2
400 Amps Hanger-Wall/Floor Flange SLWF3
600 Amps Hanger-Wall/Floor Flange SLWF4
800 Amps Hanger-Wall/Floor Flange SLWF5
800 Amps Hanger-Outlet Covers SLOC2
1Standard hanger provided unless otherwise specified.

Rev. 11/13 www.geindustrial.com BuyLog Catalog 13-51


Data subject to change
without notice
Busway Section 13
Spectra Series Busway
LowAmp
Copper Conductors

225 Amps Three-Phase, Four-Wire Integrated Housing Ground 400 Amps Three-Phase, Four-Wire Integrated Housing Ground
Component Type Product Number Component Type Product Number
Linear Lengths Plug-In: 10-ft. LP4HC02SL10 Linear Lengths Plug-In: 10-ft. LP4HC04SL10
Linear Lengths Plug-In: 6-ft. LP4HC02SL06 Linear Lengths Plug-In: 6-ft. LP4HC04SL06
Linear Lengths Plug-In: 4-ft. LP4HC02SL04 Linear Lengths Plug-In: 4-ft. LP4HC04SL04
Linear Lengths Feeder: 10-ft. LF4HC02SL10 Linear Lengths Feeder: 10-ft. LF4HC04SL10
Linear Lengths Feeder: 5-ft. LF4HC02SL05 Linear Lengths Feeder: 5-ft. LF4HC04SL05
Linear Lengths Feeder: 3-ft. LF4HC02SL03 Linear Lengths Feeder: 3-ft. LF4HC04SL03
Linear Lengths Feeder: 2-ft. LF4HC02SL02 Linear Lengths Feeder: 2-ft. LF4HC04SL02
Linear Lengths Adjustable Straight Length LF4HC02ASST Linear Lengths Adjustable Straight Length LF4HC04ASST
Fittings Elbow Left 90 LF4HC02ELST Fittings Elbow Left 90 LF4HC04ELST
Fittings Elbow Right 90 LF4HC02ERST Fittings Elbow Right 90 LF4HC04ERST
Fittings Elbow Up 90 LF4HC02EUST Fittings Elbow Up 90 LF4HC04EUST
Fittings Elbow Down 90 LF4HC02EDST Fittings Elbow Down 90 LF4HC04EDST
Accessories End Cable Tap BoxUp LF4HC02TTST Accessories End Cable Tap BoxUp LF4HC04TTST
Accessories End Cable Tap BoxDown LF4HC02TBST Accessories End Cable Tap BoxDown LF4HC04TBST
Accessories Center Cable Tap BoxUp LF4HC02CTST Accessories Center Cable Tap BoxUp LF4HC04CTST
Accessories Center Cable Tap BoxDown LF4HC02CBST Accessories Center Cable Tap BoxDown LF4HC04CBST
Accessories End Box LF4HC02EBST Accessories End Box LF4HC04EBST
Accessories Flanged End w/Lugs LF4HC02FLST Accessories Flanged End w/Lugs LF4HC04FLST
Accessories Flanged End LF4HC02FEST Accessories Flanged End LF4HC04FEST
Fittings Expansion LengthUp LF4HC02XUST Fittings Expansion LengthUp LF4HC04XUST
Fittings Expansion LengthDown LF4HC02XDST Fittings Expansion LengthDown LF4HC04XDST
Fittings Total Phase Transposition LF4HC02TFST Fittings Total Phase Transposition LF4HC04TFST
Fittings TeeRight LF4HC02TRST Fittings TeeRight LF4HC04TRST
Fittings TeeLeft LF4HC02TLST Fittings TeeLeft LF4HC04TLST
Fittings TeeUp LF4HC02TUST Fittings TeeUp LF4HC04TUST
Fittings TeeDown LF4HC02TDST Fittings TeeDown LF4HC04TDST
Fittings Off SetUp (6) LF4HC02OU06 Fittings Off SetUp (6) LF4HC04OU06
Fittings Off SetUp (12) LF4HC02OU12 Fittings Off SetUp (12) LF4HC04OU12
Fittings Off SetUp (18) LF4HC02OU18 Fittings Off SetUp (18) LF4HC04OU18
Fittings Off SetDown (6) LF4HC02OD06 Fittings Off SetDown (6) LF4HC04OD06
Fittings Off SetDown (12) LF4HC02OD12 Fittings Off SetDown (12) LF4HC04OD12
Fittings Off SetDown (18) LF4HC02OD18 Fittings Off SetDown (18) LF4HC04OD18
Fittings Off SetLeft (6) LF4HC02OL06 Fittings Off SetLeft (6) LF4HC04OL06
Fittings Off SetLeft (12) LF4HC02OL12 Fittings Off SetLeft (12) LF4HC04OL12
Fittings Off SetLeft (18) LF4HC02OL18 Fittings Off SetLeft (18) LF4HC04OL18
Fittings Off SetRight (6) LF4HC02OR0 Fittings Off SetRight (6) LF4HC04OR06
Fittings Off SetRight (12) LF4HC02OR12 Fittings Off SetRight (12) LF4HC04OR12
Fittings Off Set Right (18) LF4HC02OR18 Fittings Off Set Right (18) LF4HC04OR18

Hangers - Common to all Services


Amperage Accessory Type Product Number
800 Amps Hanger-EdgewiseTrapeze SLTE2
800 Amps Hanger-FlatwiseTrapeze SLTF2
800 Amps Hanger-EdgewiseClevis SLEC2
225 Amps Hanger-FlatwiseClevis SLFC21
400 Amps Hanger-FlatwiseClevis SLFC31
600 Amps Hanger-FlatwiseClevis SLFC41
800 Amps Hanger-FlatwiseClevis SLFC51
400 Amps Hanger-Spring Riser SLSR2
600 Amps Hanger-Spring Riser SLSR4
800 Amps Hanger-Spring Riser SLSR5
225 Amps Hanger-Wall/Floor Flange SLWF2
400 Amps Hanger-Wall/Floor Flange SLWF3
600 Amps Hanger-Wall/Floor Flange SLWF4
800 Amps Hanger-Wall/Floor Flange SLWF5
800 Amps Hanger-Outlet Covers SLOC2
1Standard hanger provided unless otherwise specified.

13-52 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Busway Section 13
Spectra Series Busway (continued)
LowAmp
Copper Conductors

600 Amps Three-Phase, Four-Wire Integrated Housing Ground 800 Amps Three-Phase, Four-Wire Integrated Housing Ground
Component Type Product Number Component Type Product Number
Linear Lengths Plug-In: 10-ft. LP4HC06SL10 Linear Lengths Plug-In: 10-ft. LP4HC08SL10
Linear Lengths Plug-In: 6-ft. LP4HC06SL06 Linear Lengths Plug-In: 6-ft. LP4HC08SL06
Linear Lengths Plug-In: 4-ft. LP4HC06SL04 Linear Lengths Plug-In: 4-ft. LP4HC08SL04
Linear Lengths Feeder: 10-ft. LF4HC06SL10 Linear Lengths Feeder: 10-ft. LF4HC08SL10
Linear Lengths Feeder: 5-ft. LF4HC06SL05 Linear Lengths Feeder: 5-ft. LF4HC08SL05
Linear Lengths Feeder: 3-ft. LF4HC06SL03 Linear Lengths Feeder: 3-ft. LF4HC08SL03
Linear Lengths Feeder: 2-ft. LF4HC06SL02 Linear Lengths Feeder: 2-ft. LF4HC08SL02
Linear Lengths Adjustable Straight Length LF4HC06ASST Linear Lengths Adjustable Straight Length LF4HC08ASST
Fittings Elbow Left 90 LF4HC06ELST Fittings Elbow Left 90 LF4HC08ELST
Fittings Elbow Right 90 LF4HC06ERST Fittings Elbow Right 90 LF4HC08ERST
Fittings Elbow Up 90 LF4HC06EUST Fittings Elbow Up 90 LF4HC08EUST
Fittings Elbow Down 90 LF4HC06EDST Fittings Elbow Down 90 LF4HC08EDST
Accessories End Cable Tap BoxUp LF4HC06TTST Accessories End Cable Tap BoxUp LF4HC08TTST
Accessories End Cable Tap BoxDown LF4HC06TBST Accessories End Cable Tap BoxDown LF4HC08TBST
Accessories Center Cable Tap BoxUp LF4HC06CTST Accessories Center Cable Tap BoxUp LF4HC08CTST
Accessories Center Cable Tap BoxDown LF4HC06CBST Accessories Center Cable Tap BoxDown LF4HC08CBST
Accessories End Box LF4HC06EBST Accessories End Box LF4HC08EBST
Accessories Flanged End w/Lugs LF4HC06FLST Accessories Flanged End w/Lugs LF4HC08FLST
Accessories Flanged End LF4HC06FEST Accessories Flanged End LF4HC08FEST
Fittings Expansion LengthUp LF4HC06XUST Fittings Expansion LengthUp LF4HC08XUST
Fittings Expansion LengthDown LF4HC06XDST Fittings Expansion LengthDown LF4HC08XDST
Fittings Total Phase Transposition LF4HC06TFST Fittings Total Phase Transposition LF4HC08TFST
Fittings TeeRight LF4HC06TRST Fittings TeeRight LF4HC08TRST
Fittings TeeLeft LF4HC06TLST Fittings TeeLeft LF4HC08TLST
Fittings TeeUp LF4HC06TUST Fittings TeeUp LF4HC08TUST
Fittings TeeDown LF4HC06TDST Fittings TeeDown LF4HC08TDST
Fittings Off SetUp (6) LF4HC06OU06 Fittings Off SetUp (6) LF4HC08OU06
Fittings Off SetUp (12) LF4HC06OU12 Fittings Off SetUp (12) LF4HC08OU12
Fittings Off SetUp (18) LF4HC06OU18 Fittings Off SetUp (18) LF4HC08OU18
Fittings Off SetDown (6) LF4HC06OD06 Fittings Off SetDown (6) LF4HC08OD06
Fittings Off SetDown (12) LF4HC06OD12 Fittings Off SetDown (12) LF4HC08OD12
Fittings Off SetDown (18) LF4HC06OD18 Fittings Off SetDown (18) LF4HC08OD18
Fittings Off SetLeft (6) LF4HC06OL06 Fittings Off SetLeft (6) LF4HC08OL06
Fittings Off SetLeft (12) LF4HC06OL12 Fittings Off SetLeft (12) LF4HC08OL12
Fittings Off SetLeft (18) LF4HC06OL18 Fittings Off SetLeft (18) LF4HC08OL18
Fittings Off SetRight (6) LF4HC06OR06 Fittings Off SetRight (6) LF4HC08OR06
Fittings Off SetRight (12) LF4HC06OR12 Fittings Off SetRight (12) LF4HC08OR12
Fittings Off Set Right (18) LF4HC06OR18 Fittings Off Set Right (18) LF4HC08OR18

Hangers - Common to all Services


Amperage Accessory Type Product Number
800 Amps Hanger-EdgewiseTrapeze SLTE2
800 Amps Hanger-FlatwiseTrapeze SLTF2
800 Amps Hanger-EdgewiseClevis SLEC2
225 Amps Hanger-FlatwiseClevis SLFC21
400 Amps Hanger-FlatwiseClevis SLFC31
600 Amps Hanger-FlatwiseClevis SLFC41
800 Amps Hanger-FlatwiseClevis SLFC51
400 Amps Hanger-Spring Riser SLSR2
600 Amps Hanger-Spring Riser SLSR4
800 Amps Hanger-Spring Riser SLSR5
225 Amps Hanger-Wall/Floor Flange SLWF2
400 Amps Hanger-Wall/Floor Flange SLWF3
600 Amps Hanger-Wall/Floor Flange SLWF4
800 Amps Hanger-Wall/Floor Flange SLWF5
800 Amps Hanger-Outlet Covers SLOC2
1Standard hanger provided unless otherwise specified.

Rev. 11/13 www.geindustrial.com BuyLog Catalog 13-53


Data subject to change
without notice
Busway Section 13
Spectra Series Busway
LowAmp
Copper Conductors

225 Amps Three-Phase, Three-Wire 400 Amps Three-Phase, Three-Wire


Internal Copper Ground Bar Internal Copper Ground Bar
Component Type Product Number Component Type Product Number
Linear Lengths Plug-In: 10-ft. LP3GC02SL10 Linear Lengths Plug-In: 10-ft. LP3GC04SL10
Linear Lengths Plug-In: 6-ft. LP3GC02SL06 Linear Lengths Plug-In: 6-ft. LP3GC04SL06
Linear Lengths Plug-In: 4-ft. LP3GC02SL04 Linear Lengths Plug-In: 4-ft. LP3GC04SL04
Linear Lengths Feeder: 10-ft. LF3GC02SL10 Linear Lengths Feeder: 10-ft. LF3GC04SL10
Linear Lengths Feeder: 5-ft. LF3GC02SL05 Linear Lengths Feeder: 5-ft. LF3GC04SL05
Linear Lengths Feeder: 3-ft. LF3GC02SL03 Linear Lengths Feeder: 3-ft. LF3GC04SL03
Linear Lengths Feeder: 2-ft. LF3GC02SL02 Linear Lengths Feeder: 2-ft. LF3GC04SL02
Linear Lengths Adjustable Straight Length LF3GC02ASST Linear Lengths Adjustable Straight Length LF3GC04ASST
Fittings Elbow Left 90 LF3GC02ELST Fittings Elbow Left 90 LF3GC04ELST
Fittings Elbow Right 90 LF3GC02ERST Fittings Elbow Right 90 LF3GC04ERST
Fittings Elbow Up 90 LF3GC02EUST Fittings Elbow Up 90 LF3GC04EUST
Fittings Elbow Down 90 LF3GC02EDST Fittings Elbow Down 90 LF3GC04EDST
Accessories End Cable Tap BoxUp LF3GC02TTST Accessories End Cable Tap BoxUp LF3GC04TTST
Accessories End Cable Tap BoxDown LF3GC02TBST Accessories End Cable Tap BoxDown LF3GC04TBST
Accessories Center Cable Tap BoxUp LF3GC02CTST Accessories Center Cable Tap BoxUp LF3GC04CTST
Accessories Center Cable Tap BoxDown LF3GC02CBST Accessories Center Cable Tap BoxDown LF3GC04CBST
Accessories End Box LF3GC02EBST Accessories End Box LF3GC04EBST
Accessories Flanged End w/Lugs LF3GC02FLST Accessories Flanged End w/Lugs LF3GC04FLST
Accessories Flanged End LF3GC02FEST Accessories Flanged End LF3GC04FEST
Fittings Expansion LengthUp LF3GC02XUST Fittings Expansion LengthUp LF3GC04XUST
Fittings Expansion LengthDown LF3GC02XDST Fittings Expansion LengthDown LF3GC04XDST
Fittings Total Phase Transposition LF3GC02TFST Fittings Total Phase Transposition LF3GC04TFST
Fittings TeeRight LF3GC02TRST Fittings TeeRight LF3GC04TRST
Fittings TeeLeft LF3GC02TLST Fittings TeeLeft LF3GC04TLST
Fittings TeeUp LF3GC02TUST Fittings TeeUp LF3GC04TUST
Fittings TeeDown LF3GC02TDST Fittings TeeDown LF3GC04TDST
Fittings Off SetUp (6) LF3GC02OU06 Fittings Off SetUp (6) LF3GC04OU06
Fittings Off SetUp (12) LF3GC02OU12 Fittings Off SetUp (12) LF3GC04OU12
Fittings Off SetUp (18) LF3GC02OU18 Fittings Off SetUp (18) LF3GC04OU18
Fittings Off SetDown (6) LF3GC02OD06 Fittings Off SetDown (6) LF3GC04OD06
Fittings Off SetDown (12) LF3GC02OD12 Fittings Off SetDown (12) LF3GC04OD12
Fittings Off SetDown (18) LF3GC02OD18 Fittings Off SetDown (18) LF3GC04OD18
Fittings Off SetLeft (6) LF3GC02OL06 Fittings Off SetLeft (6) LF3GC04OL06
Fittings Off SetLeft (12) LF3GC02OL12 Fittings Off SetLeft (12) LF3GC04OL12
Fittings Off SetLeft (18) LF3GC02OL18 Fittings Off SetLeft (18) LF3GC04OL18
Fittings Off SetRight (6) LF3GC02OR06 Fittings Off SetRight (6) LF3GC04OR06
Fittings Off SetRight (12) LF3GC02OR12 Fittings Off SetRight (12) LF3GC04OR12
Fittings Off Set Right (18) LF3GC02OR18 Fittings Off Set Right (18) LF3GC04OR18

Hangers - Common to all Services


Amperage Accessory Type Product Number
800 Amps Hanger-EdgewiseTrapeze SLTE2
800 Amps Hanger-FlatwiseTrapeze SLTF2
800 Amps Hanger-EdgewiseClevis SLEC2
225 Amps Hanger-FlatwiseClevis SLFC21
400 Amps Hanger-FlatwiseClevis SLFC31
600 Amps Hanger-FlatwiseClevis SLFC41
800 Amps Hanger-FlatwiseClevis SLFC51
400 Amps Hanger-Spring Riser SLSR2
600 Amps Hanger-Spring Riser SLSR4
800 Amps Hanger-Spring Riser SLSR5
225 Amps Hanger-Wall/Floor Flange SLWF2
400 Amps Hanger-Wall/Floor Flange SLWF3
600 Amps Hanger-Wall/Floor Flange SLWF4
800 Amps Hanger-Wall/Floor Flange SLWF5
800 Amps Hanger-Outlet Covers SLOC2
1Standard hanger provided unless otherwise specified.

13-54 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Busway Section 13
Spectra Series Busway (continued)
LowAmp
Copper Conductors

600 Amps Three-Phase, Three-Wire 800 Amps Three-Phase, Three-Wire


Internal Copper Ground Bar Internal Copper Ground Bar
Component Type Product Number Component Type Product Number
Linear Lengths Plug-In: 10-ft. LP3GC06SL10 Linear Lengths Plug-In: 10-ft. LP3GC08SL10
Linear Lengths Plug-In: 6-ft. LP3GC06SL06 Linear Lengths Plug-In: 6-ft. LP3GC08SL06
Linear Lengths Plug-In: 4-ft. LP3GC06SL04 Linear Lengths Plug-In: 4-ft. LP3GC08SL04
Linear Lengths Feeder: 10-ft. LF3GC06SL10 Linear Lengths Feeder: 10-ft. LF3GC08SL10
Linear Lengths Feeder: 5-ft. LF3GC06SL05 Linear Lengths Feeder: 5-ft. LF3GC08SL05
Linear Lengths Feeder: 3-ft. LF3GC06SL03 Linear Lengths Feeder: 3-ft. LF3GC08SL03
Linear Lengths Feeder: 2-ft. LF3GC06SL02 Linear Lengths Feeder: 2-ft. LF3GC08SL02
Linear Lengths Adjustable Straight Length LF3GC06ASST Linear Lengths Adjustable Straight Length LF3GC08ASST
Fittings Elbow Left 90 LF3GC06ELST Fittings Elbow Left 90 LF3GC08ELST
Fittings Elbow Right 90 LF3GC06ERST Fittings Elbow Right 90 LF3GC08ERST
Fittings Elbow Up 90 LF3GC06EUST Fittings Elbow Up 90 LF3GC08EUST
Fittings Elbow Down 90 LF3GC06EDST Fittings Elbow Down 90 LF3GC08EDST
Accessories End Cable Tap BoxUp LF3GC06TTST Accessories End Cable Tap BoxUp LF3GC08TTST
Accessories End Cable Tap BoxDown LF3GC06TBST Accessories End Cable Tap BoxDown LF3GC08TBST
Accessories Center Cable Tap BoxUp LF3GC06CTST Accessories Center Cable Tap BoxUp LF3GC08CTST
Accessories Center Cable Tap BoxDown LF3GC06CBST Accessories Center Cable Tap BoxDown LF3GC08CBST
Accessories End Box LF3GC06EBST Accessories End Box LF3GC08EBST
Accessories Flanged End w/Lugs LF3GC06FLST Accessories Flanged End w/Lugs LF3GC08FLST
Accessories Flanged End LF3GC06FEST Accessories Flanged End LF3GC08FEST
Fittings Expansion LengthUp LF3GC06XUST Fittings Expansion LengthUp LF3GC08XUST
Fittings Expansion LengthDown LF3GC06XDST Fittings Expansion LengthDown LF3GC08XDST
Fittings Total Phase Transposition LF3GC06TFST Fittings Total Phase Transposition LF3GC08TFST
Fittings TeeRight LF3GC06TRST Fittings TeeRight LF3GC08TRST
Fittings TeeLeft LF3GC06TLST Fittings TeeLeft LF3GC08TLST
Fittings TeeUp LF3GC06TUST Fittings TeeUp LF3GC08TUST
Fittings TeeDown LF3GC06TDST Fittings TeeDown LF3GC08TDST
Fittings Off SetUp (6) LF3GC06OU06 Fittings Off SetUp (6) LF3GC08OU06
Fittings Off SetUp (12) LF3GC06OU12 Fittings Off SetUp (12) LF3GC08OU12
Fittings Off SetUp (18) LF3GC06OU18 Fittings Off SetUp (18) LF3GC08OU18
Fittings Off SetDown (6) LF3GC06OD06 Fittings Off SetDown (6) LF3GC08OD06
Fittings Off SetDown (12) LF3GC06OD1 Fittings Off SetDown (12) LF3GC08OD12
Fittings Off SetDown (18) LF3GC06OD18 Fittings Off SetDown (18) LF3GC08OD18
Fittings Off SetLeft (6) LF3GC06OL06 Fittings Off SetLeft (6) LF3GC08OL06
Fittings Off SetLeft (12) LF3GC06OL12 Fittings Off SetLeft (12) LF3GC08OL12
Fittings Off SetLeft (18) LF3GC06OL18 Fittings Off SetLeft (18) LF3GC08OL18
Fittings Off SetRight (6) LF3GC06OR06 Fittings Off SetRight (6) LF3GC08OR06
Fittings Off SetRight (12) LF3GC06OR12 Fittings Off SetRight (12) LF3GC08OR12
Fittings Off Set Right (18) LF3GC06OR18 Fittings Off Set Right (18) LF3GC08OR18

Hangers - Common to all Services


Amperage Accessory Type Product Number
800 Amps Hanger-EdgewiseTrapeze SLTE2
800 Amps Hanger-FlatwiseTrapeze SLTF2
800 Amps Hanger-EdgewiseClevis SLEC2
225 Amps Hanger-FlatwiseClevis SLFC21
400 Amps Hanger-FlatwiseClevis SLFC31
600 Amps Hanger-FlatwiseClevis SLFC41
800 Amps Hanger-FlatwiseClevis SLFC51
400 Amps Hanger-Spring Riser SLSR2
600 Amps Hanger-Spring Riser SLSR4
800 Amps Hanger-Spring Riser SLSR5
225 Amps Hanger-Wall/Floor Flange SLWF2
400 Amps Hanger-Wall/Floor Flange SLWF3
600 Amps Hanger-Wall/Floor Flange SLWF4
800 Amps Hanger-Wall/Floor Flange SLWF5
800 Amps Hanger-Outlet Covers SLOC2
1Standard hanger provided unless otherwise specified.

Rev. 11/13 www.geindustrial.com BuyLog Catalog 13-55


Data subject to change
without notice
Busway Section 13
Spectra Series Busway
LowAmp
Copper Conductors

225 Amps Three-Phase, Four-Wire Internal Copper Ground Bus 400 Amps Three-Phase, Four-Wire Internal Copper Ground Bus
Component Type Product Number Component Type Product Number
Linear Lengths Plug-In: 10-ft. LP4GC02SL10 Linear Lengths Plug-In: 10-ft. LP4GC04SL10
Linear Lengths Plug-In: 6-ft. LP4GC02SL06 Linear Lengths Plug-In: 6-ft. LP4GC04SL06
Linear Lengths Plug-In: 4-ft. LP4GC02SL04 Linear Lengths Plug-In: 4-ft. LP4GC04SL04
Linear Lengths Feeder: 10-ft. LF4GC02SL10 Linear Lengths Feeder: 10-ft. LF4GC04SL10
Linear Lengths Feeder: 5-ft. LF4GC02SL05 Linear Lengths Feeder: 5-ft. LF4GC04SL05
Linear Lengths Feeder: 3-ft. LF4GC02SL03 Linear Lengths Feeder: 3-ft. LF4GC04SL03
Linear Lengths Feeder: 2-ft. LF4GC02SL02 Linear Lengths Feeder: 2-ft. LF4GC04SL02
Linear Lengths Adjustable Straight Length LF4GC02ASST Linear Lengths Adjustable Straight Length LF4GC04ASST
Fittings Elbow Left 90 LF4GC02ELST Fittings Elbow Left 90 LF4GC04ELST
Fittings Elbow Right 90 LF4GC02ERST Fittings Elbow Right 90 LF4GC04ERST
Fittings Elbow Up 90 LF4GC02EUST Fittings Elbow Up 90 LF4GC04EUST
Fittings Elbow Down 90 LF4GC02EDST Fittings Elbow Down 90 LF4GC04EDST
Accessories End Cable Tap BoxUp LF4GC02TTST Accessories End Cable Tap BoxUp LF4GC04TTST
Accessories End Cable Tap BoxDown LF4GC02TBST Accessories End Cable Tap BoxDown LF4GC04TBST
Accessories Center Cable Tap BoxUp LF4GC02CTST Accessories Center Cable Tap BoxUp LF4GC04CTST
Accessories Center Cable Tap BoxDown LF4GC02CBST Accessories Center Cable Tap BoxDown LF4GC04CBST
Accessories End Box LF4GC02EBST Accessories End Box LF4GC04EBST
Accessories Flanged End w/Lugs LF4GC02FLST Accessories Flanged End w/Lugs LF4GC04FLST
Accessories Flanged End LF4GC02FEST Accessories Flanged End LF4GC04FEST
Fittings Expansion LengthUp LF4GC02XUST Fittings Expansion LengthUp LF4GC04XUST
Fittings Expansion LengthDown LF4GC02XDST Fittings Expansion LengthDown LF4GC04XDST
Fittings Total Phase Transposition LF4GC02TFST Fittings Total Phase Transposition LF4GC04TFST
Fittings TeeRight LF4GC02TRST Fittings TeeRight LF4GC04TRST
Fittings TeeLeft LF4GC02TLST Fittings TeeLeft LF4GC04TLST
Fittings TeeUp LF4GC02TUST Fittings TeeUp LF4GC04TUST
Fittings TeeDown LF4GC02TDST Fittings TeeDown LF4GC04TDST
Fittings Off SetUp (6) LF4GC02OU06 Fittings Off SetUp (6) LF4GC04OU06
Fittings Off SetUp (12) LF4GC02OU12 Fittings Off SetUp (12) LF4GC04OU12
Fittings Off SetUp (18) LF4GC02OU18 Fittings Off SetUp (18) LF4GC04OU18
Fittings Off SetDown (6) LF4GC02OD06 Fittings Off SetDown (6) LF4GC04OD06
Fittings Off SetDown (12) LF4GC02OD12 Fittings Off SetDown (12) LF4GC04OD12
Fittings Off SetDown (18) LF4GC02OD18 Fittings Off SetDown (18) LF4GC04OD18
Fittings Off SetLeft (6) LF4GC02OL06 Fittings Off SetLeft (6) LF4GC04OL06
Fittings Off SetLeft (12) LF4GC02OL12 Fittings Off SetLeft (12) LF4GC04OL12
Fittings Off SetLeft (18) LF4GC02OL18 Fittings Off SetLeft (18) LF4GC04OL18
Fittings Off SetRight (6) LF4GC02OR06 Fittings Off SetRight (6) LF4GC04OR06
Fittings Off SetRight (12) LF4GC02OR12 Fittings Off SetRight (12) LF4GC04OR12
Fittings Off Set Right (18) LF4GC02OR18 Fittings Off SetRight (18) LF4GC04OR18

Hangers - Common to all Services


Amperage Accessory Type Product Number
800 Amps Hanger-EdgewiseTrapeze SLTE2
800 Amps Hanger-FlatwiseTrapeze SLTF2
800 Amps Hanger-EdgewiseClevis SLEC2
225 Amps Hanger-FlatwiseClevis SLFC21
400 Amps Hanger-FlatwiseClevis SLFC31
600 Amps Hanger-FlatwiseClevis SLFC41
800 Amps Hanger-FlatwiseClevis SLFC51
400 Amps Hanger-Spring Riser SLSR2
600 Amps Hanger-Spring Riser SLSR4
800 Amps Hanger-Spring Riser SLSR5
225 Amps Hanger-Wall/Floor Flange SLWF2
400 Amps Hanger-Wall/Floor Flange SLWF3
600 Amps Hanger-Wall/Floor Flange SLWF4
800 Amps Hanger-Wall/Floor Flange SLWF5
800 Amps Hanger-Outlet Covers SLOC2
1Standard hanger provided unless otherwise specified.

13-56 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Busway Section 13
Spectra Series Busway (continued)
LowAmp
Copper Conductors

600 Amps Three-Phase, Four-Wire Internal Copper Ground Bus 800 Amps Three-Phase, Four-Wire Internal Copper Ground Bus
Component Type Product Number Component Type Product Number
Linear Lengths Plug-In: 10-ft. LP4GC06SL10 Linear Lengths Plug-In: 10-ft. LP4GC08SL10
Linear Lengths Plug-In: 6-ft. LP4GC06SL06 Linear Lengths Plug-In: 6-ft. LP4GC08SL06
Linear Lengths Plug-In: 4-ft. LP4GC06SL04 Linear Lengths Plug-In: 4-ft. LP4GC08SL04
Linear Lengths Feeder: 10-ft. LF4GC06SL10 Linear Lengths Feeder: 10-ft. LF4GC08SL10
Linear Lengths Feeder: 5-ft. LF4GC06SL05 Linear Lengths Feeder: 5-ft. LF4GC08SL05
Linear Lengths Feeder: 3-ft. LF4GC06SL03 Linear Lengths Feeder: 3-ft. LF4GC08SL03
Linear Lengths Feeder: 2-ft. LF4GC06SL02 Linear Lengths Feeder: 2-ft. LF4GC08SL02
Linear Lengths Adjustable Straight Length LF4GC06ASST Linear Lengths Adjustable Straight Length LF4GC08ASST
Fittings Elbow Left 90 LF4GC06ELST Fittings Elbow Left 90 LF4GC08ELST
Fittings Elbow Right 90 LF4GC06ERST Fittings Elbow Right 90 LF4GC08ERST
Fittings Elbow Up 90 LF4GC06EUST Fittings Elbow Up 90 LF4GC08EUST
Fittings Elbow Down 90 LF4GC06EDST Fittings Elbow Down 90 LF4GC08EDST
Accessories End Cable Tap BoxUp LF4GC06TTST Accessories End Cable Tap BoxUp LF4GC08TTST
Accessories End Cable Tap BoxDown LF4GC06TBST Accessories End Cable Tap BoxDown LF4GC08TBST
Accessories Center Cable Tap BoxUp LF4GC06CTST Accessories Center Cable Tap BoxUp LF4GC08CTST
Accessories Center Cable Tap BoxDown LF4GC06CBST Accessories Center Cable Tap BoxDown LF4GC08CBST
Accessories End Box LF4GC06EBST Accessories End Box LF4GC08EBST
Accessories Flanged End w/Lugs LF4GC06FLST Accessories Flanged End w/Lugs LF4GC08FLST
Accessories Flanged End LF4GC06FEST Accessories Flanged End LF4GC08FEST
Fittings Expansion LengthUp LF4GC06XUST Fittings Expansion LengthUp LF4GC08XUST
Fittings Expansion LengthDown LF4GC06XDST Fittings Expansion LengthDown LF4GC08XDST
Fittings Total Phase Transposition LF4GC06TFST Fittings Total Phase Transposition LF4GC08TFST
Fittings TeeRight LF4GC06TRST Fittings TeeRight LF4GC08TRST
Fittings TeeLeft LF4GC06TLST Fittings TeeLeft LF4GC08TLST
Fittings TeeUp LF4GC06TUST Fittings TeeUp LF4GC08TUST
Fittings TeeDown LF4GC06TDST Fittings TeeDown LF4GC08TDST
Fittings Off SetUp (6) LF4GC06OU06 Fittings Off SetUp (6) LF4GC08OU06
Fittings Off SetUp (12) LF4GC06OU12 Fittings Off SetUp (12) LF4GC08OU12
Fittings Off SetUp (18) LF4GC06OU18 Fittings Off SetUp (18) LF4GC08OU18
Fittings Off SetDown (6) LF4GC06OD06 Fittings Off SetDown (6) LF4GC08OD06
Fittings Off SetDown (12) LF4GC06OD12 Fittings Off SetDown (12) LF4GC08OD12
Fittings Off SetDown (18) LF4GC06OD18 Fittings Off SetDown (18) LF4GC08OD18
Fittings Off SetLeft (6) LF4GC06OL06 Fittings Off SetLeft (6) LF4GC08OL06
Fittings Off SetLeft (12) LF4GC06OL12 Fittings Off SetLeft (12) LF4GC08OL12
Fittings Off SetLeft (18) LF4GC06OL18 Fittings Off SetLeft (18) LF4GC08OL18
Fittings Off SetRight (6) LF4GC06OR06 Fittings Off SetRight (6) LF4GC08OR06
Fittings Off SetRight (12) LF4GC06OR12 Fittings Off SetRight (12) LF4GC08OR12
Fittings Off Set Right (18) LF4GC06OR18 Fittings Off Set Right (18) LF4GC08OR18

Hangers - Common to all Services


Amperage Accessory Type Product Number
800 Amps Hanger-EdgewiseTrapeze SLTE2
800 Amps Hanger-FlatwiseTrapeze SLTF2
800 Amps Hanger-EdgewiseClevis SLEC2
225 Amps Hanger-FlatwiseClevis SLFC21
400 Amps Hanger-FlatwiseClevis SLFC31
600 Amps Hanger-FlatwiseClevis SLFC41
800 Amps Hanger-FlatwiseClevis SLFC51
400 Amps Hanger-Spring Riser SLSR2
600 Amps Hanger-Spring Riser SLSR4
800 Amps Hanger-Spring Riser SLSR5
225 Amps Hanger-Wall/Floor Flange SLWF2
400 Amps Hanger-Wall/Floor Flange SLWF3
600 Amps Hanger-Wall/Floor Flange SLWF4
800 Amps Hanger-Wall/Floor Flange SLWF5
800 Amps Hanger-Outlet Covers SLOC2
1Standard hanger provided unless otherwise specified.

Rev. 11/13 www.geindustrial.com BuyLog Catalog 13-57


Data subject to change
without notice
Busway Section 13
Spectra Series Busway
LowAmp
Circuit Breaker Busway Plugs

Features and Benefits Low-Tier Frames Three-Phase, Three-Wire SFHA


Rating Plug: simplifies factory floor and equipment changeovers Short Circuit Short Circuit Short Circuit
Trip Rating Rating Rating Product
because plug has trip/amp interchangeability. Amps @ 240V (kAIC) @ 480V (kAIC) @ 600V (kAIC) Number
True Digital rms Sensing: more accurate and reliable trip 70 65 25 18 SL37SFHG
interruption. 90 65 25 18 SL39SFHG
100 65 25 18 SL310SFHG
High Interrupting Rating: satisfies high IC requirements up to 110 65 25 18 SL311SFHG
100 kAIC @ 480V. 125 65 25 18 SL312SFHG
UL Listed and CSA Certified: for heat rise, short-circuit, and 150 65 25 18 SL315SFHG
175 65 25 18 SL317SFHG
ground fault. 200 65 25 18 SL320SFHG
Interlocks and Safety Features: door interlock, plug interlock, 225 65 25 18 SL322SFHG
250 65 25 18 SL325SFHG
ground contact before stab contact, and plug assist for
mechanical installation.
Breakers must be factory-installed.
Low-Tier Frames Three-Phase, Four-Wire SEDA
Short Circuit Short Circuit Short Circuit
Trip Rating Rating Rating Product
Low-Tier Frames Three-Phase, Three-Wire SEDA Amps @ 240V (kAIC) @ 480V (kAIC) @ 600V (kAIC) Number
Short Circuit Short Circuit Short Circuit 15 18 14 14 SL41SEDG
Trip Rating Rating Rating Product
20 18 14 14 SL42SEDG
Amps @ 240V (kAIC) @ 480V (kAIC) @ 600V (kAIC) Number
30 18 14 14 SL43SEDG
15 18 14 14 SL31SEDG 40 18 14 14 SL44SEDG
20 18 14 14 SL32SEDG 50 18 14 14 SL45SEDG
30 18 14 14 SL33SEDG 60 18 14 14 SL46SEDG
40 18 14 14 SL34SEDG 70 18 14 14 SL47SEDG
50 18 14 14 SL35SEDG 80 18 14 14 SL48SEDG
60 18 14 14 SL36SEDG 90 18 14 14 SL49SEDG
70 18 14 14 SL37SEDG 100 18 14 14 SL410SEDG
80 18 14 14 SL38SEDG 110 18 14 14 SL411SFDG
90 18 14 14 SL39SEDG 125 18 14 14 SL412SEDG
100 18 14 14 SL310SEDG 150 18 14 14 SL415SEDG
110 18 14 14 SL311SEDG
125 18 14 14 SL312SEDG
150 18 14 14 SL315SEDG
Low-Tier Frames Three-Phase, Four-Wire SEHA
Short Circuit Short Circuit Short Circuit
Trip Rating Rating Rating Product
Low-Tier Frames Three-Phase, Three-Wire SEHA Amps @ 240V (kAIC) @ 480V (kAIC) @ 600V (kAIC) Number
Short Circuit Short Circuit Short Circuit 15 65 25 18 SL41SEH
Trip Rating Rating Rating Product
20 65 25 18 SL42SEHG
Amps @ 240V (kAIC) @ 480V (kAIC) @ 600V (kAIC) Number
30 65 25 18 SL43SEHG
15 65 25 18 SL31SEHG 40 65 25 18 SL44SEHG
20 65 25 18 SL32SEHG 50 65 25 18 SL45SEHG
30 65 25 18 SL33SEHG 60 65 25 18 SL46SEHG
40 65 25 18 SL34SEHG 70 65 25 18 SL47SEHG
50 65 25 18 SL35SEHG 80 65 25 18 SL48SEHG
60 65 25 18 SL36SEHG 90 65 25 18 SL49SEHG
70 65 25 18 SL37SEHG 100 65 25 18 SL410SEHG
80 65 25 18 SL38SEHG 110 65 25 18 SL411SEHG
90 65 25 18 SL39SEHG 125 65 25 18 SL412SEHG
100 65 25 18 SL310SEHG 150 65 25 18 SL415SEHG
110 65 25 18 SL311SEHG
125 65 25 18 SL312SEHG
150 65 25 18 SL315SEHG

13-58 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Busway Section 13
Spectra Series Busway (continued)
LowAmp
Circuit Breaker Busway Plugs

Low-Tier Frames Three-Phase, Four-Wire SFHA Mid-Tier Frames Three-Phase, Four-Wire SFLA
Short Circuit Short Circuit Short Circuit Short Circuit Short Circuit Short Circuit
Trip Rating Rating Rating Product Trip Rating Rating Rating Product
Amps @ 240V (kAIC) @ 480V (kAIC) @ 600V (kAIC) Number Amps @ 240V (kAIC) @ 480V (kAIC) @ 600V (kAIC) Number
70 65 25 18 SL47SFHG 70 100 65 25 SL47SFLG
90 65 25 18 SL49SFHG 90 100 65 25 SL49SFLG
100 65 25 18 SL410SFHG 100 100 65 25 SL410SFLG
110 65 25 18 SL411SFHG 110 100 65 25 SL411SFLG
125 65 25 18 SL412SFHG 125 100 65 25 SL412SFLG
150 65 25 18 SL415SFHG 150 100 65 25 SL415SFLG
175 65 25 18 SL417SFHG 175 100 65 25 SL417SFLG
200 65 25 18 SL420SFHG 200 100 65 25 SL420SFLG
225 65 25 18 SL422SFHG 225 100 65 25 SL422SFLG
250 65 25 18 SL425SFHG 250 100 65 25 SL425SFLG

Mid-Tier Frames Three-Phase, Three-Wire SELA Without Rating Plug Three-Phase, Three-Wire
Short Circuit Short Circuit Short Circuit Frame Type Trip Amps Product Number
Trip Rating Rating Rating Product
Amps @ 240V (kAIC) @ 480V (kAIC) @ 600V (kAIC) Number SEDGA 15-30 SL301SEDG
SEDGA 40-60 SL302SEDG
15 100 65 25 SL31SELG SEDGA 70-100 SL303SEDG
20 100 65 25 SL32SELG SEDGA 110-150 SL304SEDG
30 100 65 25 SL33SELG SEHGA 15-30 SL301SEHG
40 100 65 25 SL34SELG SEHGA 40-60 SL302SEHG
50 100 65 25 SL35SELG SEHGA 70-100 SL303SEHG
60 100 65 25 SL36SELG SEHGA 110-150 SL304SEHG
70 100 65 25 SL37SELG SFHGA 70-250 SL300SFHG
80 100 65 25 SL38SELG SELGA 15-30 SL301SELG
90 100 65 25 SL39SELG SELGA 40-60 SL302SELG
100 100 65 25 SL310SELG SELGA 70-100 SL303SELG
110 100 65 25 SL311SELG SELGA 110-150 SL304SELG
125 100 65 25 SL312SELG SFLGA 70-250 SL300SFLG
150 100 65 25 SL315SELG SEPGA 15-30 SL301SEPG
SEPGA 40-60 SL302SEPG
SEPGA 70-100 SL303SEPG
SEPGA 110-150 SL304SEPG
Mid-Tier Frames Three-Phase, Three-Wire SFLA
Short Circuit Short Circuit Short Circuit
Trip Rating Rating Rating Product
Amps @ 240V (kAIC) @ 480V (kAIC) @ 600V (kAIC) Number Without Rating Plug Three-Phase, Four-Wire
70 100 65 25 SL37SFLG Frame Type Trip Amps Product Number
90 100 65 25 SL39SFLG
SEDA 15-30 SL401SEDG
100 100 65 25 SL310SFLG
SEDA 40-60 SL402SEDG
110 100 65 25 SL311SFLG
SEDA 70-100 SL403SEDG
125 100 65 25 SL312SFLG
SEDA 110-150 SL404SEDG
150 100 65 25 SL315SFLG
SEHA 15-30 SL401SEHG
175 100 65 25 SL317SFLG
SEHA 40-60 SL402SEHG
200 100 65 25 SL320SFLG
SEHA 70-100 SL403SEHG
225 100 65 25 SL322SFLG
SEHA 110-150 SL404SEHG
250 100 65 25 SL325SFLG
SFHA 70-250 SL400SFHG
SELA 15-30 SL401SELG
SELA 40-60 SL402SELG
Mid-Tier Frames Three-Phase, Four-Wire SELA SELA 70-100 SL403SELG
SELA 110-150 SL404SELG
Short Circuit Short Circuit Short Circuit SFLA 70-250 SL400SFLG
Trip Rating Rating Rating Product
Amps @ 240V (kAIC) @ 480V (kAIC) @ 600V (kAIC) Number
15 100 65 25 SL41SELG
20 100 65 25 SL42SELG
30 100 65 25 SL43SELG
40 100 65 25 SL44SELG
50 100 65 25 SL45SELG
60 100 65 25 SL46SELG
70 100 65 25 SL47SELG
80 100 65 25 SL48SELG
90 100 65 25 SL49SELG
100 100 65 25 SL410SELG
110 100 65 25 SL411SELG
125 100 65 25 SL412SELG
150 100 65 25 SL415SELG

Rev. 11/13 www.geindustrial.com BuyLog Catalog 13-59


Data subject to change
without notice
Busway Section 13
Spectra Series Busway (continued)
LowAmp
Circuit Breaker Busway Plugs

Circuit Breaker Plugs - Standard Frames Three-Phase, Circuit Breaker Plugs - Standard Frames Three-Phase,
Three-Wire TEB Four-Wire TED4
Short Circuit Rating Product Trip Short Circuit Rating Short Circuit Rating Product
Trip Amps @ 240V (kAIC) Number Amps @ 240V (kAIC) @ 480V (kAIC) Number
15 10 SL31EBG 15 18 14 SL41ED4G
20 10 SL32EBG 20 18 14 SL42ED4G
30 10 SL33EBG 30 18 14 SL43ED4G
40 10 SL34EBG 40 18 14 SL44ED4G
50 10 SL35EBG 50 18 14 SL45ED4G
60 10 SL36EBG 60 18 14 SL46ED4G
70 10 SL37EBG 70 18 14 SL47ED4G
100 10 SL310EBG 100 18 14 SL410ED4G

Circuit Breaker Plugs - Standard Frames Three-Phase, Circuit Breaker Plugs - Standard Frames Three-Phase,
Three-Wire TED4 Four-Wire TED6
Trip Short Circuit Rating Short Circuit Rating Product Short Circuit Short Circuit Short Circuit
Amps @ 240V (kAIC) @ 480V (kAIC) Number Trip Rating Rating Rating Product
Amps @ 240V (kAIC) @ 480V (kAIC) @ 600V (kAIC) Number
15 18 14 SL31ED4G
20 18 14 SL32ED4G 15 18 14 14 SL41ED6G
30 18 14 SL33ED4G 20 18 14 14 SL42ED6G
40 18 14 SL34ED4G 30 18 14 14 SL43ED6G
50 18 14 SL35ED4G 40 18 14 14 SL44ED6G
60 18 14 SL36ED4G 50 18 14 14 SL45ED6G
70 18 14 SL37ED4G 60 18 14 14 SL46ED6G
100 18 14 SL310ED4G 70 18 14 14 SL47ED6G
100 18 14 14 SL410ED6G

Circuit Breaker Plugs - Standard Frames Three-Phase,


Enclosure Only
Three-Wire TED6
Short Circuit Short Circuit Short Circuit Service Type Frame Type Trip Amps Product Number
Trip Rating Rating Rating Product
Three-Phase,
Amps @ 240V (kAIC) @ 480V (kAIC) @ 600V (kAIC) Number
Three-Wire E 100 A max. SL3100EG
15 18 14 14 SL31ED6G Three-Phase,
20 18 14 14 SL32ED6G Three-Wire F 225 A max. SL3225FG
30 18 14 14 SL33ED6G Three-Phase,
40 18 14 14 SL34ED6G Four-Wire E 100 A max. SL4100EG
50 18 14 14 SL35ED6G Three-Phase,
60 18 14 14 SL36ED6G Four-Wire F 225 A max. SL4225FG
70 18 14 14 SL37ED6G
100 18 14 14 SL310ED6G (Order circuit breaker from Section 6)
Not for Spectra breakers. E and F frame enclosures for standard molded case cir-
cuit breakers only.

Circuit Breaker Plugs - Standard Frames Three-Phase,


Four-Wire TEB
Short Circuit Rating Product
Trip Amps @ 240V (kAIC) Number
15 10 SL41EBG
20 10 SL42EBG
30 10 SL43EBG
40 10 SL44EBG
50 10 SL45EBG
60 10 SL46EBG
70 10 SL47EBG
100 10 SL410EBG

13-60 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Busway Section 13
Spectra Series Busway
LowAmp
Busway Plugs, Fusible, Conversion Kits

Switch-Operated Fusible Plugs Three-Phase, Three-Wire Fusible Switch Unit Options


Voltage Trip Amps Product Number Use for Spectra Series Busway
240Vac 30 SL321RG
240Vac 60 SL322RG Fusible Switch Units are available in 30, 60, 100, 200 and 400
240Vac 100 SL323RG amps and have the following options:
240Vac 200 SL324RG
240Vac 400 SL325RG
Factory installed Class R fuse clips
480/600Vac 30 SL361RG Factory installed Class J fuse clips
480/600Vac 60 SL362RG QMW in lieu of QMR
480/600Vac 100 SL363RG
480/600Vac 200 SL364RG
Contact the factory for pricing details.
480/600Vac 400 SL365RG

With QMR Interrupter Fuses Not Included


Miscellaneous Plug Modifications
Drip-Resistant Plug: includes cover and stab gasketing. Add
Switch-Operated Fusible Plugs Three-Phase, Four-Wire suffix "I" to product number.
Voltage Trip Amps Product Number Plug Assist: standard for plugs over 100 amperes. Add suffix "P"
240 30 SL421RG to the product number for plugs 100 amperes and below.
240 60 SL422RG
240 100 SL423RG
240 200 SL424RG
240 400 SL425RG
480/600 30 SL461RG
480/600 60 SL462RG
480/600 100 SL463RG
480/600 200 SL464RG
480/600 400 SL465RG

With QMR Interrupter Fuses Not Included

Adapter Kits
Convert Spectra Series LowAmp plugs to Spectra Series Bus.
Ground stabs included.
Amperage Product Number
30-100 SLSB1G
200-250 SLSB4G
400-600 SLSB5G

Adapter Kits
Convert Spectra Series Bus Plugs to Spectra LowAmp Bus.
(Style 2shipped after 5/95.) Ground stabs included.
Amperage Product Number
30-100 SBSL1G
200-225 SBSL4G
400-600 SBSL5G

Adapter Kits
Convert Armor-Clad to Spectra Series LowAmp
(Style 8 shipped after 5/95.) Ground stabs included.
Amperage Product Number
30-100 ACSL1G
200-225 ACSL4G
400 ACSL5G

Rev. 11/13 www.geindustrial.com BuyLog Catalog 13-61


Data subject to change
without notice
Busway Section 13
Spectra Series Busway
LowAmp
Busway
Outlines and Dimensions

Linear Lengths Three-Phase, Three-Wire


Plug-In and Feeder. All Bus are UL listed at 600 Volts.
Conductor A Width Bar Sizes - DC Ampere Approx. Weight Approx. Weight Linear Lengths
Material Amperage (inches, mm) Width x Thickness (in.) Rating1 Lbs./Ft. Kg/M Plug-in and Feeder, one bar per phase.
Aluminum 225 Amps 3 (76) .750 x .250 225 5.1 7.6
Aluminum 400 Amps 3 3/8 (86) 1.125 x .250 600 5.8 8.6
Aluminum 600 Amps 4 (102) 1.750 x .250 800 7 10.4
Aluminum 800 Amps 5 (127) 2.875 x .250 1200 9.1 13.5
Copper 225 Amps 3 (76) .750 x .250 225 6.6 9.8
Copper 400 Amps 3 (76) .750 x .250 600 6.6 9.8
Copper 600 Amps 3 3/8 (86) 1.125 x .250 800 8.1 12.1
Copper 800 Amps 4 (102) 1.750 x .250 1200 10.5 15.6
1DC Bus. is 4-wire with + + polarity.

Spring Riser
Linear Lengths Three-Phase, Four-Wire
Plug-In and Feeder. All Bus are UL listed at 600 Volts
Conductor A Width Bar Sizes - DC Ampere Approx. Weight Approx. Weight
Material Amperage (inches, mm) Width x Thickness (in.) Rating Lbs./Ft. Kg/M
Aluminum 225 Amps 3 (76) .750 x .250 225 5.4 8
Aluminum 400 Amps 3 3/8 (86) 1.125 x .250 600 6 8.9
Aluminum 600 Amps 4 (102) 1.750 x .250 800 7.5 11.2
Aluminum 800 Amps 5 (127) 2.875 x .250 1200 10 14.9
Copper 225 Amps 3 (76) .750 x .250 225 7.4 11
Copper 400 Amps 3 (76) .750 x .250 600 7.4 11
Copper 600 Amps 3 3/8 (86) 1.125 x .250 800 9.2 13.7
Copper 800 Amps 4 (102) 1.750 x .250 1200 12.2 18.2 (Standard) Flatwise Hanger
1DC Bus. is 4-wire with + + polarity. Shipped with Each Straight Length

Conversion Chart
Decimal Fraction
.12 1/8
.63 5/8
.88 7/8

Hangers - Vertical Mounting Clevis Hanger for Edgewise Mounting


Spring hangers are required to support the busway at each floor. When the floor-to-floor
span is over 16 feet, support for the spring hanger should be provided. Simple adjust-
ment procedures are included with installation instructions. Mounting holes align with
floor flanges.

Hangers - Horizontal Mounting


One standard flatwise clevis-type hanger is furnished with each straight length.
Edgewise clevis and edgewise/flatwise trapeze hangers are optionally available. Drop
rods are not furnished.
Trapeze Hanger for Edgewise Mounting

Trapeze Hanger for Flatwise Mounting

13-62 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Busway Section 13
Spectra Series Busway
LowAmp
Busway
Outlines and Dimensions

End Cable Tap Boxes - Lugs per Phase


Amperage No. of #2-600kcmil Lugs/ N & GRD
225 Amps 1
400 Amps 2
600 Amps 2
800 Amps 3
Center Cable Tap Box: Feeder or Plug-In
End Boxes are required to terminate busway runs. No joint assembly is required, and
the end surface of the box is even with the joint centerline. See table on page
13-62 for A dimension. Box is secured via joint cap bolts.

Center Cable Tap Boxes - Lugs per Phase


Amperage No. of #2-600kcmil Lugs/ N & GRD
225 Amps 1
400 Amps 2
600 Amps 2
800 Amps 3

Floor/Wall Flange Cutout and Drilling Detail Standard Center Cable Tap Box Down Position, Side View
Bar Width (mm) Dimension X (mm) Dimension Y (mm)
.750 5.000 8.500
1.125 5.375 8.875
1.750 6.000 9.500
2.875 7.125 10.625

Note: Floor or wall opening should provide 1/2" clearance all around the Busway.

Inverted Center Cable Tap Box Up Position, Side View

End Cable Tap Box: Feeder or Plug-In

End Box

Standard End Cable Tap Box Down Position, Side View

Inverted End Tap Box Up Position, Side View Wall/Floor Flange

Rev. 11/13 www.geindustrial.com BuyLog Catalog 13-63


Data subject to change
without notice
Busway Section 13
Spectra Series Busway
LowAmp
Busway
Outlines and Dimensions

Molded-Case Circuit Breakers - Outer Dimensions


Standard and Hi-Break
Frame Type Trip Amps Voltage Width (in.) Length (in.) Depth (in.) Figure No.
TEB 15-100 240 11 13 8 A
TED, THED 15-100 600 11 13 8 A
TED, THED 110-150 600 11 13 8 A

Molded-Case Circuit Breakers - Outer Dimensions


Low- and Mid-Tier
Frame Type Trip Amps Voltage Width (in.) Length (in.) Depth (in.) Figure No.
SED, SEH, SEL 15-150 480 11 13 8 A
SFHA 70-225 600 11 21.25 9 A

Figure A
Fusible Switches Outer Dimensions Door hinges at left end. All dimensions
are shown over largest part of plug.
Type QMR
Weight Width Length (in.) Length (in.) Depth Figure
Voltage Amperage (Lbs.) (in.) Standard Gutter Extended Gutter (in.) No.
240 and 600 30 24 11.25 13 18.63 8.75 A
240 and 600 60 25 11.25 13 18.63 8.75 A
240 and 600 100 28 11.25 18.75 N/A 8.75 A
240 and 600 200 46 16 18.75 24.5 8.75 A
240 and 600 400 135 20.5 18.75 N/A 18.75 B

Figure B
Door hinges at top. All dimensions
are shown over largest part of plug.

13-64 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Busway Section 13
Spectra Series Busway
LowAmp
Busway
Outlines and Dimensions

Fittings - Elbows, Tees and Offsets


Spectra Series LowAmp busway has a complete family of standard catalog fittings to meet virtually all layout requirements using the
compact minimum sizes shown.
Nomenclature for completely defining the turn is accomplished by looking into the joint end with phase side facing down on the
busway. Using this guideline, a right elbow turns right, an up elbow turns up, etc.
Every piece of busway is labeled to maintain proper phasing. Unless otherwise noted, all turn dimensions are defined from the center-
line of the joint end to the centerline of the busway. Figures show dimensions for elbow, tee, and offset fittings.

Up 90 Elbow Shown (Down 90 Elbow Reversed) Offset Right Shown (Left Offset Reversed)

Offset Down Shown (Offset Up Reversed) Tee Right Shown (Left Tee Reversed)

Tee Down Shown (Up Tee Reversed) Elbow 90 Right Shown (Left Elbow Reversed)

Rev. 11/13 www.geindustrial.com BuyLog Catalog 13-65


Data subject to change
without notice
Busway Section 13
Flex-A-Power Busway
Type DH
Aluminum Conductors

Product Features Three-Phase, Three-Wire, AC Standard


Type DH plug-in and feeder busway distributes power through a Component Type Product Number

wide variety of indoor locations where there is a need for small Linear Lengths 10-ft. DP3HA01SL10
Linear Lengths 6 ft. DP3HA01SL06
blocks of conveniently available power. Type DH busway has a Linear Lengths 2-ft. DP3HA01SL02
lower installed cost than wire and conduit, yet has all the advan- Accessories End Tap Boxes DP3HA01TSST
tages and features of plug-in busway. Available Ratings: 100 Straight Bar end
Accessories End Tap Boxes DP3HA01TOST
amperes, 600 volts, indoor enclosures only. Offset Bar End
Accessories Center (Joint) DP3HA01CCST
Tap Boxes
Accessories End (Stub) Straight DP3HA01SSST
Applications Bar end
Type DH busway provides a ready power source for small Fittings Offset Bar End DP3HA01SOST

machines, portable electric tools, lights, and a variety of other


equipment. Type DH busway can serve as either a plug-in or
feeder system, with 10 outlets available in every 10-foot length. It Three-Phase, Three-Wire, AC Internal Ground Bar
Component Type Product Number
may be tapped by circuit breaker, fusible or unfused plugs.
Linear Lengths 10-ft. DP3GA01SL10
Linear Lengths 6 ft. DP3GA01SL06
Linear Lengths 2-ft. DP3GA01SL02
Single-Phase, Three-Wire AC; Three-Wire DC Standard Accessories End Tap Boxes DP3GA01TSST
Component Type Product Number Straight Bar end
Accessories End Tap Boxes DP3GA01TOST
Linear Lengths 10-ft. DP1HA01SL10 Offset Bar End
Linear Lengths 6 ft. DP1HA01SL06 Accessories Center (Joint) DP3GA01CCST
Linear Lengths 2-ft. DP1HA01SL02 Tap Boxes
Accessories End Tap Boxes DP1HA01TSST Accessories End (Stub) Straight DP3GA01SSST
Straight Bar end Bar end
Accessories End Tap Boxes DP1HA01TOST Fittings Offset Bar End DP3GA01SOST
Offset Bar End
Accessories Center (Joint) DP1HA01CCST
Tap Boxes
Accessories End (Stub) Straight DP1HA01SSST Three-Phase, Four-Wire AC Standard
Bar end
Component Type Product Number
Fittings Offset Bar End DP1HA01SOST
Linear Lengths 10-ft. DP4HA01SL10
Linear Lengths 6 ft. DP4HA01SL06
Linear Lengths 2-ft. DP4HA01SL02
Single-Phase, Three-Wire AC; Accessories End Tap Boxes DP4HA01TSST
Three-Wire DC Internal Ground Bar Straight Bar end
Accessories End Tap Boxes DP4HA01TOST
Component Type Product Number Offset Bar End
Linear Lengths 10-ft. DP1GA01SL10 Accessories Center (Joint) DP4HA01CCST
Linear Lengths 6 ft. DP1GA01SL06 Tap Boxes
Linear Lengths 2-ft. DP1GA01SL02 Accessories End (Stub) Straight DP4HA01SSST
Accessories End Tap Boxes DP1GA01TSST Bar end
Straight Bar end Fittings Offset Bar End DP4HA01SOST
Accessories End Tap Boxes DP1GA01TOST
Offset Bar End
Accessories DP1GA01CCST
Accessories End (Stub) Straight DP1GA01SSST
Three-Phase, Four-Wire AC Internal Ground Bar
Bar end Component Type Product Number
Fittings Offset Bar End DP1GA01SOST
Linear Lengths 10-ft. DP4GA01SL10
Linear Lengths 6 ft. DP4GA01SL06
Linear Lengths 2-ft. DP4GA01SL02
Accessories End Tap Boxes DP4GA01TSST
Straight Bar end
Accessories End Tap Boxes DP4GA01TOST
Offset Bar End
Accessories Center (Joint) DP4GA01CCST
Tap Boxes
Accessories End (Stub) Straight DP4GA01SSST
Bar end
Fittings Offset Bar End DP4GA01SOST

13-66 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Busway Section 13
Flex-A-Power Busway (continued)
Type DH
Aluminum Conductors

Devices Common to All Three- and Four-Wire Systems Devices Common to All Three- and Four-Wire Systems
Standard Internal Ground Bar
Component Type Product Number Component Type Product Number
Fittings Elbows Up DP4HA01EUST Fittings Elbows Up DP4GA01EUST
Fittings Elbows Down DP4HA01EDST Fittings Elbows Down DP4GA01EDST
Fittings Elbows Left DP4HA01ELST Fittings Elbows Left DP4GA01ELST
Fittings Elbows Right DP4HA01ERST Fittings Elbows Right DP4GA01ERST
Fittings Tees Up DP4HA01TUST Fittings Tees Up DP4GA01TUST
Fittings Tees Down DP4HA01TDST Fittings Tees Down DP4GA01TDST
Fittings Tees Left DP4HA01TLST Fittings Tees Left DP4GA01TLST
Fittings Tees Right DP4HA01TRST Fittings Tees Right DP4GA01TRST
Fittings Crosses Up-Down DP4HA01CDST Fittings Crosses Left-Right DP4GA01CLST
Fittings Crosses Left-Right DP4HA01CLST Fittings Crosses Up-Down DP4GA01CDST
Fittings Reverse Fittings Straight DP4HA01RSST Fittings Reverse Fittings Straight DP4GA01RSST
Bar End Bar End
Fittings Reverse Fittings DP4HA01ROST Fittings Reverse Fittings DP4GA01ROST
Offset Bar End Offset Bar End
Linear Lengths Adjustable Lengths DP4HA01ASST Linear Lengths Adjustable Lengths DP4GA01ASST
Accessories End Boxes DP4HA01EBST Accessories End Boxes DP4GA01EBST
Accessories Flanges DH1F Accessories Flanges DH1F
Accessories Outlet Covers DH10C Accessories Outlet Covers DH10C
Accessories Hangers (Edgewise) DE1HES Accessories Hangers (Edgewise) DE1HES
Single Run Single Run
Accessories Hangers (Edgewise) Single DH1HU1 Accessories Hangers (Edgewise) Single DH1HU1
Run (wall/ceiling mtg.) Run (wall/ceiling mtg.)
Accessories Hangers (Edgewise) DE1HED Accessories Hangers (Edgewise) DE1HED
Double Run Double Run

Rev. 11/13 www.geindustrial.com BuyLog Catalog 13-67


Data subject to change
without notice
Busway Section 13
Flex-A-Power Busway
Type DH
Copper Conductors

Product Features Three-Phase, Three-Wire, AC Standard


Type DH plug-in and feeder busway distributes power through a Component Type Product Number

wide variety of indoor locations where there is a need for small Linear Lengths 10-ft. DP3HC01SL10
Linear Lengths 6 ft. DP3HC01SL06
blocks of conveniently available power. Type DH busway has a Linear Lengths 2-ft. DP3HC01SL02
lower installed cost than wire and conduit, yet has all the advan- Accessories End Tap Boxes DP3HC01TSST
tages and features of plug-in busway. Available Ratings: 100 Straight Bar end
Accessories End Tap Boxes DP3HC01TOST
amperes, 600 volts, indoor enclosures only. Offset Bar End
Accessories Center (Joint) DP3HC01CCST
Tap Boxes
Accessories End (Stub) Straight DP3HC01SSST
Applications Bar end
Type DH busway provides a ready power source for small Fittings Offset Bar End DP3HC01SOST

machines, portable electric tools, lights, and a variety of other


equipment. Type DH busway can serve as either a plug-in or
feeder system, with 10 outlets available in every 10-foot length. It Three-Phase, Three-Wire, AC Internal Ground Bar
Component Type Product Number
may be tapped by circuit breaker, fusible or unfused plugs.
Linear Lengths 10-ft. DP3GC01SL10
Linear Lengths 6 ft. DP3GC01SL06
Linear Lengths 2-ft. DP3GC01SL02
Single-Phase, Three-Wire AC; Three-Wire DC Standard Accessories End Tap Boxes DP3GC01TSST
Component Type Product Number Straight Bar end
Accessories End Tap Boxes DP3GC01TOST
Linear Lengths 10-ft. DP1HC01SL10 Offset Bar End
Linear Lengths 6 ft. DP1HC01SL06 Accessories Center (Joint) DP3GC01CCST
Linear Lengths 2-ft. DP1HC01SL02 Tap Boxes
Accessories End Tap Boxes DP1HC01TSST Accessories End (Stub) Straight DP3GC01SSST
Straight Bar end Bar end
Accessories End Tap Boxes DP1HC01TOST Fittings Offset Bar End DP3GC01SOST
Offset Bar End
Accessories Center (Joint) DP1HC01CCST
Tap Boxes
Accessories End (Stub) Straight DP1HC01SSST Three-Phase, Four-Wire AC Standard
Bar end
Component Type Product Number
Fittings Offset Bar End DP1HC01SOST
Linear Lengths 10-ft. DP4HC01SL10
Linear Lengths 6 ft. DP4HC01SL06
Linear Lengths 2-ft. DP4HC01SL02
Single-Phase, Three-Wire AC; Three-Wire DC Accessories End Tap Boxes DP4HC01TSST
Internal Ground Bar Straight Bar end
Accessories End Tap Boxes DP4HC01TOST
Component Type Product Number Offset Bar End
Linear Lengths 10-ft. DP1GC01SL10 Accessories Center (Joint) DP4HC01CCST
Linear Lengths 6 ft. DP1GC01SL06 Tap Boxes
Linear Lengths 2-ft. DP1GC01SL02 Accessories End (Stub) Straight DP4HC01SSST
Accessories End Tap Boxes DP1GC01TSST Bar end
Straight Bar end Fittings Offset Bar End DP4HC01SOST
Accessories End Tap Boxes DP1GC01TOST
Offset Bar End
Accessories Center (Joint) DP1GC01CCST
Tap Boxes
Three-Phase, Four-Wire AC Internal Ground Bar
Accessories End (Stub) Straight DP1GC01SSST Component Type Product Number
Bar end
Linear Lengths 10-ft. DP4GC01SL10
Fittings Offset Bar End DP1GC01SOST
Linear Lengths 6 ft. DP4GC01SL06
Linear Lengths 2-ft. DP4GC01SL02
Accessories End Tap Boxes DP4GC01TSST
Straight Bar end
Accessories End Tap Boxes DP4GC01TOST
Offset Bar End
Accessories Center (Joint) DP4GC01CCST
Tap Boxes
Accessories End (Stub) Straight DP4GC01SSST
Bar end
Fittings Offset Bar End DP4GC01SOST

13-68 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Busway Section 13
Flex-A-Power Busway (continued)
Type DH
Copper Conductors

Devices Common to All Three- and Four-Wire Systems Devices Common to All Three- and Four-Wire Systems
Standard Internal Ground Bar
Component Type Product Number Component Type Product Number
Fittings Elbows Up DP4HC01EUST Fittings Elbows Up DP4GC01EUST
Fittings Elbows Down DP4HC01EDST Fittings Elbows Down DP4GC01EDST
Fittings Elbows Left DP4HC01ELST Fittings Elbows Left DP4GC01ELST
Fittings Elbows Right DP4HC01ERST Fittings Elbows Right DP4GC01ERST
Fittings Tees Up DP4HC01TUST Fittings Tees Up DP4GC01TUST
Fittings Tees Down DP4HC01TDST Fittings Tees Down DP4GC01TDST
Fittings Tees Left DP4HC01TLST Fittings Tees Left DP4GC01TLST
Fittings Tees Right DP4HC01TRST Fittings Tees Right DP4GC01TRST
Fittings Crosses Up-Down DP4HC01CDST Fittings Crosses Up-Down DP4GC01CDST
Fittings Crosses Left-Right DP4HC01CLST Fittings Crosses Left-Right DP4GC01CLST
Fittings Reverse Fittings Straight DP4HC01RSST Fittings Reverse Fittings Straight DP4GC01RSST
Bar End Bar End
Fittings Reverse Fittings DP4HC01ROST Fittings Reverse Fittings DP4GC01ROST
Offset Bar End Offset Bar End
Linear Lengths Adjustable Lengths DP4HC01ASST Linear Lengths Adjustable Lengths DP4GC01ASST
Accessories End Boxes DP4HC01EBST Accessories End Boxes DP4GC01EBST
Accessories Flanges DH1F Accessories Flanges DH1F
Accessories Outlet Covers DH10C Accessories Outlet Covers DH10C
Accessories Hangers (Edgewise) DE1HES Accessories Hangers (Edgewise) DE1HES
Single Run Single Run
Accessories Hangers (Edgewise) Single DH1HU1 Accessories Hangers (Edgewise) Single DH1HU1
Run (wall/ceiling mtg.) Run (wall/ceiling mtg.)
Accessories Hangers (Edgewise) DE1HED Accessories Hangers (Edgewise) DE1HED
Double Run Double Run

Rev. 11/13 www.geindustrial.com BuyLog Catalog 13-69


Data subject to change
without notice
Busway Section 13
Flex-A-Power Busway
Type DH
Plugs

Unfused - Type TB Three-Phase, Four-Wire, Single-Phase, Three-Wire


Amperage Voltage Product Number
60 600 DHIP4TB2

Unfused - Type TB Three-Phase, Three-Wire Type TB


Amperage Voltage Product Number
60 600 DHIP3TB2

Circuit Breaker Plugs - Type TQL Single-Phase, Three-Wire


Amperage Frame Type Voltage Product Number
15-50 TQL 240 Max DFPTQL3N
15-50 TQLX 240 Max DFPTQLX3N
15-50 TQLR 240 Max DFPTQLR3N
15-50 TQLRC 240 Max DFPTQLRC41

(With Space Only for Three THQL Breaker Poles) Handle-Operated Type TQL
Order breakers separately.
1C in Product Number indicates screw tightening housing clips.

Circuit Breaker Plugs - Type TQL Three-Phase, Three-Wire


Amperage Frame Type Voltage Product Number
15-50 TQL 240 Max DFPTQL3
15-50 TQLX 240 Max DFPTQLX3
15-50 TQLR 240 Max DFPTQLR3

(With Space Only for Three THQL Breaker Poles)


Order breakers separately. Type TQLR with Receptacle Provision
Circuit Breaker Plugs - Type TQL Three-Phase, Four-Wire
Amperage Frame Type Voltage Product Number
15-50 TQL 240 Max DFPTQL4
15-50 TQLX 240 Max DFPTQLX4
15-50 TQLR 240 Max DFPTQLR4
15-50 TQLC 240 Max DFPTQLC41
15-50 TQLRC 240 Max DFPTQLRC41

(With Space Only for Three THQL Breaker Poles)


Order breakers separately.
1C in Product Number indicates screw tightening housing clips. Type TQLX Externally Operated Handle

Circuit Breaker Plugs - Type TE Single-Phase, Three-Wire


Amperage Frame Type Voltage Product Number
15-70 TE 600 Max DFPTE3N
15-70 TEX 600 Max DFPTEX3N
15-70 TER 600 Max DFPTER3N

(With Space Only for Three TEB or TED4 Breaker Poles)


Order breakers separately.

Circuit Breaker Plugs - Type TE Three-Phase, Three-Wire Handle-Operated TE


Amperage Frame Type Voltage Product Number
15-70 TE 600 Max DFPTE3
15-70 TEX 600 Max DFPTEX3
15-70 TER 600 Max DFPTER3

(With Space Only for Three TEB or TED4 Breaker Poles)


Order breakers separately.

Circuit Breaker Plugs - Type TE Three-Phase, Four-Wire


Amperage Frame Type Voltage Product Number
15-70 TE 600 Max DFPTE4 TER with Receptacle Provision
15-70 TEX 600 Max DFPTEX4
15-70 TER 600 Max DFPTER4
15-70 TEC 600 Max DFPTEC4
15-70 TERC 600 Max DFPTERC4

(With Space Only for Three TEB or TED4 Breaker Poles)


Order breakers separately.

TEX Externally Operated Handle

13-70 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Busway Section 13
Flex-A-Power Busway
Type DH
Plugs

Fusible - Type QMR Single-Phase, Three-Wire Circuit Breakers Three-Phase, Three-Wire


Amperage Voltage Product Number Amperage Frame Type Voltage Product Number1
30 240 DH421R 15 TEB 240 DH31EB
60 240 DH422R 20 TEB 240 DH32EB
100 240 DH423R 30 TEB 240 DH33EB
30 600 DH461R 40 TEB 240 DH34EB
60 600 DH462R 50 TEB 240 DH35EB
100 600 DH463R 70 TEB 240 DH37EB
100 TEB 240 DH310EB
With Class H Fuse Clips 15 TED4 480 DH31ED4
Fuses Not Included 20 TED4 480 DH32ED4
30 TED4 480 DH33ED4
40 TED4 480 DH34ED4
50 TED4 480 DH35ED4
Fusible - Type QMR Three-Phase, Three-Wire 70 TED4 480 DH37ED4
Amperage Voltage Product Number 100 TED4 480 DH310ED4
30 240 DH321R 15 TED6 600 DH31ED6
60 240 DH322R 20 TED6 600 DH32ED6
100 240 DH323R 30 TED6 600 DH33ED6
30 600 DH361R 40 TED6 600 DH34ED6
60 600 DH362R 50 TED6 600 DH35ED6
100 600 DH363R 70 TED6 600 DH37ED6
100 TED6 600 DH310ED6
With Class H Fuse Clips
Fuses Not Included Breakers are installed in factory.

Fusible - Type QMR Three-Phase, Four-Wire Circuit Breakers Three-Phase, Four-Wire


Amperage Frame Type Voltage Product Number1
Amperage Voltage Product Number
15 TEB 240 DH41EB
30 240 DH421R
20 TEB 240 DH42EB
60 240 DH422R
30 TEB 240 DH43EB
100 240 DH423R
40 TEB 240 DH44EB
30 600 DH461R
50 TEB 240 DH45EB
60 600 DH462R
70 TEB 240 DH47EB
100 600 DH463R
100 TEB 240 DH410EB
With Class H Fuse Clips 15 TED4 480 DH41ED4
Fuses Not Included 20 TED4 480 DH42ED4
30 TED4 480 DH43ED4
40 TED4 480 DH44ED4
50 TED4 480 DH45ED4
Circuit Breakers Single-Phase, Three-Wire 70 TED4 480 DH47ED4
Amperage Frame Type Voltage Product Number1 100 TED4 480 DH410ED4
15 TED6 600 DH41ED6
15 TEB 240 DH41EB 20 TED6 600 DH42ED6
20 TEB 240 DH42EB 30 TED6 600 DH43ED6
30 TEB 240 DH43EB 40 TED6 600 DH44ED6
40 TEB 240 DH44EB 50 TED6 600 DH45ED6
50 TEB 240 DH45EB 70 TED6 600 DH47ED6
70 TEB 240 DH47EB 100 TED6 600 DH410ED6
100 TEB 240 DH410EB
15 TED4 480 DH41ED4 Breakers are installed in factory.
20 TED4 480 DH42ED4 1These are three-phase, four-wire plugs. The A phase is ignored.
30 TED4 480 DH43ED4
40 TED4 480 DH44ED4
50 TED4 480 DH45ED4
70 TED4 480 DH47ED4 Type DH Plug Modifications
100 TED4 480 DH410ED4
15 TED6 600 DH41ED6
Ground stab - for plugs used with internal ground bus.
20 TED6 600 DH42ED6 No-fuse switch plugs.
30 TED6 600 DH43ED6
40 TED6 600 DH44ED6 Class R Fuse Clips - add suffix R.
50 TED6 600 DH45ED6
70 TED6 600 DH47ED6 Class J Fuse Clips - add suffix J for ratings 30 through 100 amps.
100 TED6 600 DH410ED6

Breakers are installed in factory.


1These are three-phase, four-wire plugs. The A phase is ignored.

Rev. 11/13 www.geindustrial.com BuyLog Catalog 13-71


Data subject to change
without notice
Busway Section 13
Flex-A-Power Busway
Type DH
Plugs

DHBusway Product Numbering System

D P 3 H C 01 SL 02
Description Code
Product DH - Busway D Configurations Code Type Feet Code
Type Plug-In P Straight Length SL 2 02
1PH, 3W 1 ElbowLeft EL Plug-In 6 06
Service 3PH, 3W 3 ElbowRight ER 10 10
3PH, 4W 100% Neutral 4 ElbowUp EU Fittings NA ST
Integrated Housing H ElbowDown ED
Ground
Internal Bus G Center Cable Tap Box CC
Copper C End Cable Tap Box Straight Bar TS
Conductor
Aluminum A End Cable Tap Box Offset Bar TO
End Stub Straight Bar SS
Amps Code End Stub Off-set Bar SO
100 01 End Box EB
TeeRight TR
TeeLeft TL
TeeDown TD
TeeUp TU
Cross Up/Down CD
Cross Left/Right CL
Adjustable Straight Length AS
Reverse Fitting Straight Bar RS
Reverse Fitting Offset Bar RO

13-72 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Busway Section 13
Flex-A-Power Busway
Type DH
Dimensions

End Stub Center Joint Tap Box Elbow Down Tee Down

Linear Lengths Single Run (wall/ceiling mtg) Elbow Left Tee Left
Hanger

Tap Box-Straight Bar End Hanger Edgewise Elbow Right Tee Right

Tap Box-Offset Bar End Elbow Up Tee Up

Rev. 11/13 www.geindustrial.com BuyLog Catalog 13-73


Data subject to change
without notice
Busway Section 13
LW Busway
Replacement Parts
Application

Product Information Plug-In Tap Boxes


Type LW plug-in busway replacement parts are available for Product
Accessory Type Service Type Amperage Voltage Number
existing systems.
Tap Box 2 or 3-pole 30 300 V LW3B30
Tap Boxes Single Fuse 2-pole 30 120 LW2F30
Tap Boxes Two Fuses 3-pole 30 120/240 V LW32F30
Available Ratings Tap Boxes Three Fuses 3-pole 30 250 V LW3F30
Tap Boxes Single Fuse 2-pole 20 300 V LW2F3202
Amperes: 30 and 60 amperes Tap Boxes Two Fuses 2-pole 20 480 V LW22F4202
Voltage: 250 or 300Vac Tap Boxes Two Fuses 3-pole 20 480/277V LW32F4202,4
Tap BoxesHandle 2-pole 15 120 V LW2C153
Busing: Copper through Cover:
Systems: Two- and Three-wire Single-PoleTHQC
Enclosures: Indoor only Tap BoxesHandle 2-pole 20 120 V LW2C203
through Cover:
Single-PoleTHQC
Tap BoxesHandle 2-pole 30 120 LW2C303
Application through Cover:
Single-PoleTHQC
Type LW busway can be used in a variety of indoor applications, Tap BoxesHandle 3-pole 15 120/240 V LW32C153
by using the variety of hangers and feed-in boxes available. The through Cover:
300 Volt, three-wire busway can be used on 480 Y/277 Volt appli- Two-PoleTHQC
Tap BoxesHandle 3-pole 20 120/240 V LW32C203
cations because the maximum voltage to ground is less than 300 through Cover:
Volts when using two phases and neutral. Two-PoleTHQC
Tap BoxesHandle 3-pole 30 120/240 V LW32C303
through Cover:
Two-PoleTHQC
Feed-In Boxes Three-Phase, Two-Wire Tap BoxesHandle 3-pole 15 240 V LW3C153
Type Amperage Product Number through Cover:
Three-PoleTHQC
Feed-In Boxes End Overslung 30 LW23TEA Tap BoxesHandle 3-pole 20 240 V LW3C203
Feed-In Boxes End Overslung 60 LW26TEA through Cover:
Feed-In Boxes End Underslung 30 LW23EB Three-PoleTHQC
Feed-In Boxes End Underslung 60 LW26EB Tap BoxesHandle 3-pole 30 240 V LW3C303
Feed-In Boxes End Miniature 30 LW23EM through Cover:
Feed-In Boxes Center Overslung 30 LW23TCA1 Three-PoleTHQC
Feed-In Boxes Center Overslung 60 LW26TCA1 Tap BoxesExternal 2-pole 15 120 V LW2C15X3
Feed-In Boxes Center Underslung 30 LW23CB Operating Handle
Feed-In Boxes Center Underslung 60 LW26CB Single-PoleTHQC
Couplings and connectors included. Tap BoxesExternal 2-pole 20 120 V LW2C20X3
1Suitable for use in flush installations in T-bar ceilings. Operating Handle
Single-PoleTHQC
Tap BoxesExternal 2-pole 30 120 LW2C30X3
Operating Handle
Feed-In Boxes Three-Phase, Three-Wire Single-PoleTHQC
Tap BoxesExternal 3-pole 15 120/240 V LW32C15X3
Type Amperage Product Number
Operating Handle
Feed-In Boxes End Overslung 30 LW33TEA Two-PoleTHQC
Feed-In Boxes End Overslung 60 LW36TEA Tap BoxesExternal 3-pole 20 120/240 V LW32C20X3
Feed-In Boxes End Underslung 30 LW33EB Operating Handle
Feed-In Boxes End Underslung 60 LW36EB Two-PoleTHQC
Feed-In Boxes End Miniature 30 LW33EM Tap BoxesExternal 3-pole 30 120/240 V LW32C30X3
Feed-In Boxes Center Overslung 30 LW33TCA1 Operating Handle
Feed-In Boxes Center Overslung 60 LW36TCA1 Two-PoleTHQC
Feed-In Boxes Center Underslung 30 LW33CB Tap BoxesExternal 3-pole 15 240 V LW3C15X3
Feed-In Boxes Center Underslung 60 LW36CB Operating Handle
Three-PoleTHQC
Couplings and connectors included.
Tap BoxesExternal 3-pole 20 240 V LW3C20X3
Two-phases and neutral from 480 Y/277 Volt system, 300 Volts maximum to ground. Operating Handle
1Suitable for use in flush installations in T-bar ceilings.
Three-PoleTHQC
Tap BoxesExternal 3-pole 30 240 V LW3C30X3
Operating Handle
Three-PoleTHQC

(Polarity of single-pole devices can be reversed in the field.)


230 amp fusible tap boxes also available (accepts 25 and 30 amp class G fuses).
Contact your local GE Sales Office.
3Includes circuit breaker.
4Two-phases and neutral from 480 Y/277 Volt system, 300 Volts maximum to
ground.

13-74 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Busway Section 13
LW Busway (continued)
Replacement Parts
Application

Busway Plugs and Receptacles


Service Bus Bar Product
Plug Type Type Amperage Voltage Contact Number
Terminal 2-pole 20A 300 V A-N LWTPA1
Plug only
Terminal 2-pole 20A 300 V A-N LWTPAG1,2
Plug only
Terminal 2-pole 20A 300 V B-N LWTPB1
Plug only
Terminal 2-pole 20A 300 V B-N LWTPBG1,2
Plug only
Terminal 2-pole 20A, 5A 300 V, A-B LWTPAB1
Plug only 480 V
Terminal 3-pole 20A, 5A 300 V, A-B-N LW3TP1
Plug only 480 V
Receptacle 2-pole 15A 125 V A-N LWRPA1
only
Receptacle 2-pole 15A 125 V B-N LWRPB1
only
Terminal and 2-pole 15A 125 V A-N LWTRPA1
Receptacle (Receptacle
Applications)
Terminal and 2-pole 20A 300 V B-N LWTRPB1
Receptacle (Terminal
Applications)
Fixture-Plug 2-pole 20A 300 V AN LWFPA
Fixture-Plug 2-pole 20A 300 V BN LWFPB
Fixture-Plug 3-pole 20A 300 V A-B-N LW3FP
Fusible 2-pole 15A 125 Vac N/A DFP21G
Convenience- (Polarized)
Plug with
Grounding Pin

(Polarity of single-pole devices can be reversed in the field.)


1Polarity can be reversed in the field.
2Includes ground stab. This plug is designed and polarized for three-wire applica-
tions using the B conductor of the busway as a continuous ground. Polarity
must not be reversed in the field.

Rev. 11/13 www.geindustrial.com BuyLog Catalog 13-75


Data subject to change
without notice
Busway Section 13
LW Busway
Replacement Parts
Dimensions
Feed-in Boxes

Feed-In Boxes Center Overslung


Amperage Dimension A Dimension B Dimension C
30 9.63 4.56 3.06
60 11.69 4.81 3.81

End Feed Overslung

Feed-In Boxes Center Underslung


Amperage Dimension A Dimension B Dimension C
30 9.63 4.06 3.06
60 11.69 4.31 3.81

End Feed Underslung

End Feed Miniature (#12 wire max.)

Center Feed Overslung

Center Feed Underslung

13-76 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Busway Section 13
LW Busway
Replacement Parts
Dimensions
Plug-in Tap Boxes and Plugs

Unfused Terminal Plug Cable Clamp Included

Fusible and Circuit Breaker Terminal and Receptacle


Plug Cable Clamp Included

Circuit Breaker, Externally Operated Handle

Rev. 11/13 www.geindustrial.com BuyLog Catalog 13-77


Data subject to change
without notice
Page Updated 12 / 2016

Busway Section 13
Lighting Busway
Type LTG
Plug-in
Application

Type LTG Plug-in Busway Feed-in Boxes


Type LTG plug-in busway is a unique four-wire system designed Type Figure No.1 Std. Pkg. Product Number

for convenient distribution of power for lighting or similar light- Feed-In Boxes 4 1 DFEB422
Surface Mounting
duty loads. End
Feed-In Boxes 4 1 DFCB422
Surface Mounting
Available Ratings Center
Feed-In Boxes 5 1 DAOCBB422
Amperes: 50 amperes Suspended Mounting
Voltage: 300 Volts or less, AC or DC Center
DAOCSC4222
Feed-In Boxes 5 1
E
LE T
Busing: Copper Suspended Mounting
Service Type: Three-phase, four-wire Sectionalizing
Enclosures: Indoor only Feed-In Boxes
Underslung Mounting
6
B SO 1 DASCBB422

Center
Feed-In Boxes 6
O 1 DASCSB4222
Application Underslung Mounting
Sectionalizing
Type LTG busway is designed for use on three-phase, four-wire 1See page 13-80.
systems that are rated 300 Volts or less. It is available in five- and 2Not UL listed.
ten-foot lengths only.

Fittings
Ordering Type Figure No.1 Std. Pkg. Product Number
E
LE T
Type LTG is ordered by product number. Two hangers should be Elbows Edgewise, 9 1 DAIEB422
included for each ten feet of busway, and these must be priced Internal
Elbows Edgewise, 10
SO 1 DAEEB422

OB
separately. Coupling sets are required to connect busway External
sections, feed-in boxes, or elbows, and these must be ordered Elbows Flat, Internal 8 1 DAIFEB422
separately. Elbows Flat, External 7 1 DAOFEB422

Linear Lengths and Coupling Hardware


Type Figure No.1 Std. Pkg. Product Number Type Figure No.1 Std. Pkg. Product Number

10 feet
5 feet OBSOLETE
1
1
1
1
DLTGB422
DLTGB4225
Hanger Plate (Only
with Screws for
Surface-Mounting
11 1 DLTGF

Coupling Set (1 1 DLTGBCP4


Plate with LTG)
4 Connectors) End Cap with Screws 14 1 DLTGEC
Hanger Plate with 13 1
Coupling Plate (only)
Bus Connector (only)
2
3
1
1
DLTGCP
DLTGBC Messenger Cable
ET E DLTGMF1

OL
Hook
Order one coupling set for each busway length, feed-in box, and elbow. Combination Rod and 12
S 1 DLTGMF3

OB
1See page 13-80. Messenger Cable Hanger
Fixture Hook 15 1 DLTGFH

Order two hangers for each 10 feet of busway.


1See page 13-80.

Unfused Plugs Terminal (only)


ET E
Bus Bar Product

OL
Service Type Amperage Voltage Contact Std. Pkg. Number

S
OB
4-pole 20 240 AC A-B 1 DATRP4213
3Includes cable clamp and ground terminal.

13-78 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Page Updated 12 / 2016
Busway Section 13
Lighting Busway (continued)
Type LTG
Plug-in
Application

Unfused Plugs Terminal and Receptacle (Includes Type THQL circuit breakers.)
Service Figure Bus Bar Std. Product
Type No.1 Amperage Voltage Contact Pkg. Number
2-pole 16 20 120Vac A-N 20 DATRP2214AG2
(Terminal), (Terminal),
15 120Vac/
(Receptacle) 240Vdc
(Receptacle)
2-pole 16 20 240Vac B-N 20 DATRP2214BG2
(Terminal), (Terminal),
15 120Vac/
(Receptacle) 240Vdc
(Receptacle)
2-pole 16 15 125Vdc C-N 20 DATRP2214CG2
(Terminal), (Terminal),
15 120Vac/
(Receptacle) 240Vdc
(Receptacle)
1See page 13-80.
2Includes cable clamp and ground terminal.

Unfused Plugs Conduit Box


Service Figure Bus Bar Std. Product
Type No.1 Amperage Voltage Contact Pkg. Number
2-pole 17 20 120Vac A-N 1 DAUC2214A
2-pole 17 20 240Vac B-N 1 DAUC2214B
2-pole 17 15 125Vdc C-N 1 DAUC2214C
4-pole 17 20 OBSOLETE
240Vac A-B-C-N 1 DAUC421A
1See page 13-80.

Fusible Plugs Single Fuse


Service Figure Bus Bar Std. Product
Type No.1 Amperage Voltage Contact Pkg. Number
2-pole 18 20 120Vac/ A-N 1 DFC2214A
125Vdc
2-pole 18 20 120Vac/ B-N 1 DFC2214B
125Vdc
2-pole 18 20 120Vac/ C-N 1 DFC2214C
125Vdc
1See page 13-80.
Fuses not included.

Fusible Plugs 3 Fuses


Service Figure
ET E
Bus Bar Std. Product
Type No.1 Amperage

O L
Voltage Contact Pkg. Number
4-pole 18 20
S 240Vac A-B-C-N 1 DFC421
1See page 13-80.
Fuses not included.
OB
Circuit Breaker Plugs One Single-Pole Breaker
Service Figure Bus Bar Std. Product
Type No.1 Amperage Voltage Contact Pkg. Number
2-pole 19 15 120Vac A-N 1 DATLB21154A
2-pole 19 15 120Vac B-N 1 DATLB21154B
2-pole 19 15 120Vac C-N 1 DATLB21154C
2-pole 19 20 120Vac A-N 1 DATLB21204A
2-pole 19 20 120Vac B-N 1 DATLB21204B
2-pole 19 20 120Vac C-N 1 DATLB21204C
2-pole 19 20 120Vac A-N 1 DATLB21203
1See page 13-80.
3On a three wire system the plug can contact either the A-N or the B-N.

Rev. 11/13 www.geindustrial.com BuyLog Catalog 13-79


Data subject to change
without notice
Page Updated 12 / 2016
Busway Section 13
Lighting Busway
Type LTG
Plug-in
Outlines and Dimensions

ET E ET E
S OL S OL
OB OB
Fig. 1 Fig. 6 Fig. 11 Fig. 16

ET E ET E
O L O L
S S
OB OB
Fig. 2 Fig. 7 Fig. 12 Fig. 17

ET E ET E
O L O L
S S
OB OB
Fig. 3 Fig. 8 Fig. 13 Fig. 18

ET E
O L
S
OB

Fig. 4 Fig. 9 Fig. 14 Fig. 19

ET E ET E ET E
O L O L O L
S S S
OB OB OB
Fig. 5 Fig. 10 Fig. 15

13-80 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Busway Section 13
Armor-Clad Busway
Transition Sections and Accessories

General Transition Section Dimensions


GE will continue to support your Armor-Clad busway needs with a The following shows dimensions for transition sections:
variety of items allowing you to modify, expand and replace your Armor-Clad to Spectra/LowAmp Transition
current system. GE offers transition pieces, bus plugs, switchboard (Standard 3-foot length; call for custom lengths.)
stubs, cable tap boxes, and other items.

Short-Circuit Ratings
For bus plug short-circuit ratings, see Spectra ratings on page 13-4.

Ordering
Prior to ordering transition pieces and accessories, you will need
to obtain the following information to ensure compatibility with
your existing Armor-Clad busway system:
Material: Aluminum or Copper bus bars? Armor-Clad to Spectra to Armor-Clad Transition
Ground bar: Optional copper ground bar? (Standard 5-foot length; call for custom lengths.)
Service: 3- or 4-wire system?
Amperes: What ampere is required?
Phase: What is A phase location?
Joint Type: Bolt-in or Slot-in joint?

Plug Dimensions
For bus plug dimensions and weights, see Spectra plugs on
page 13-35.

Armor-Clad Nomenclature

Rev. 11/13 www.geindustrial.com BuyLog Catalog 13-81


Data subject to change
without notice
Busway Section 13
Armor-Clad Busway
Busway Plugs

Specification Check Standard Frames Three-Phase, Three-Wire TFK


Exclusive Plug Assistfor mechanical installation on an Voltage Trip Amps

E T EProduct Number

energized busway run.


Ground Contactbefore stab contact.
600 Volts Inter. Trip
600 Volts Inter. Trip

S O
70
100
L AC37FKG
AC310FKG

B
600 Volts Inter. Trip 125 AC312FKG
Interlockto insure that plug is off when engaging bus and
when removing plug.
Door Interlockplug must be off to open door.
600 Volts Inter. Trip
600 Volts Inter. Trip
600 Volts Inter. Trip O 150
200
225
AC315FKG
AC320FKG
AC322FKG

Standard Frames Three-Phase, Three-Wire TJJ


Standard Frames Three-Phase, Three-Wire TEB
Voltage Trip Amps Product Number
Voltage Trip Amps Product Number
600 Volts Fixed Trip 125 AC312JJG
240 Volts Fixed Trip 15 AC31EBG 600 Volts Fixed Trip 150 AC315JJG
240 Volts Fixed Trip 20 AC32EBG 600 Volts Fixed Trip 200 AC320JJG
240 Volts Fixed Trip 30 AC33EBG 600 Volts Fixed Trip 225 AC322JJG
240 Volts Fixed Trip 40 AC34EBG 600 Volts Fixed Trip 300 AC330JJG
240 Volts Fixed Trip 50 AC35EBG 600 Volts Fixed Trip 400 AC340JJG
240 Volts Fixed Trip 70 AC37EBG
240 Volts Fixed Trip 100 AC310EBG

Standard Frames Three-Phase, Three-Wire TJK4


Standard Frames Three-Phase, Three-Wire TED4 Voltage Trip Amps Product Number

Voltage Trip Amps Product Number 600 Volts Inter. Trip 125 AC312JK4G
600 Volts Inter. Trip 150 AC315JK4G
480 Volts Fixed Trip 15 AC31ED4G 600 Volts Inter. Trip 175 AC317JK4G
480 Volts Fixed Trip 20 AC32ED4G 600 Volts Inter. Trip 200 AC320JK4G
480 Volts Fixed Trip 30 AC33ED4G 600 Volts Inter. Trip 225 AC322JK4G
480 Volts Fixed Trip 40 AC34ED4G 600 Volts Inter. Trip 300 AC330JK4G
480 Volts Fixed Trip 50 AC35ED4G 600 Volts Inter. Trip 400 AC340JK4G
480 Volts Fixed Trip 60 AC36ED4G
480 Volts Fixed Trip 70 AC37ED4G
480 Volts Fixed Trip 100 AC310ED4G
Standard Frames Three-Phase, Three-Wire TJK6
Voltage Trip Amps Product Number
Standard Frames Three-Phase, Three-Wire TED6 600 Volts Inter. Trip 400 AC340JK6G
Voltage Trip Amps Product Number 600 Volts Inter. Trip 450 AC345JK6G
600 Volts Inter. Trip 500 AC350JK6G
600 Volts Fixed Trip 15 AC31ED6G 600 Volts Inter. Trip 600 AC360JK6G
600 Volts Fixed Trip 20 AC32ED6G
600 Volts Fixed Trip 30 AC33ED6G
600 Volts Fixed Trip 40 AC34ED6G
600 Volts Fixed Trip 50 AC35ED6G Standard Frames Three-Phase, Three-Wire TKM8

ETE
600 Volts Fixed Trip 70 AC37ED6G
Voltage Trip Amps Product Number
600 Volts Fixed Trip 100 AC310ED6G
600 Volts Inter. Trip
600 Volts Inter. Trip
600 Volts Inter. Trip

S O L
300
400
500
AC330KMG
AC340KMG
AC350KMG

OB
Standard Frames Three-Phase, Three-Wire TFJ 600 Volts Inter. Trip 600 AC360KMG

ETE
Voltage Trip Amps Product Number 600 Volts Inter. Trip 700 AC370KMG
600 Volts Inter. Trip 800 AC380KMG
600 Volts Fixed Trip 70 AC37FJG
600 Volts Fixed Trip
600 Volts Fixed Trip

S O L
100
110
AC310FJG
AC311FJG

OB
600 Volts Fixed Trip 125 AC312FJG
600 Volts Fixed Trip 150 AC315FJG
600 Volts Fixed Trip 200 AC320FJG
600 Volts Fixed Trip 225 AC322FJG

13-82 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Busway Section 13
Armor-Clad Busway (continued)
Busway Plugs

Standard Frames Three-Phase, Four-Wire TEB Standard Frames Three-Phase, Four-Wire TJJ
Voltage Trip Amps Product Number Voltage Trip Amps Product Number
240 Volts Fixed Trip 15 AC41EBG 600 Volts Fixed Trip 125 AC412JJG
240 Volts Fixed Trip 20 AC42EBG 600 Volts Fixed Trip 150 AC415JJG
240 Volts Fixed Trip 30 AC43EBG 600 Volts Fixed Trip 200 AC420JJG
240 Volts Fixed Trip 40 AC44EBG 600 Volts Fixed Trip 225 AC422JJG
240 Volts Fixed Trip 50 AC45EBG 600 Volts Fixed Trip 300 AC430JJG
240 Volts Fixed Trip 70 AC47EBG 600 Volts Fixed Trip 400 AC440JJG
240 Volts Fixed Trip 100 AC410EBG

Standard Frames Three-Phase, Four-Wire TJK4


Standard Frames Three-Phase, Four-Wire TED4 Voltage Trip Amps Product Number
Voltage Trip Amps Product Number
600 Volts Inter. Trip 125 AC412JK4G
480 Volts Fixed Trip 15 AC41ED4G 600 Volts Inter. Trip 150 AC415JK4G
480 Volts Fixed Trip 20 AC42ED4G 600 Volts Inter. Trip 175 AC417JK4G
480 Volts Fixed Trip 30 AC43ED4G 600 Volts Inter. Trip 200 AC420JK4G
480 Volts Fixed Trip 40 AC44ED4G 600 Volts Inter. Trip 225 AC422JK4G
480 Volts Fixed Trip 50 AC45ED4G 600 Volts Inter. Trip 300 AC430JK4G
480 Volts Fixed Trip 60 AC46ED4G 600 Volts Inter. Trip 400 AC440JK4G
480 Volts Fixed Trip 70 AC47ED4G
480 Volts Fixed Trip 100 AC410ED4G

Standard Frames Three-Phase, Four-Wire TJK6


Voltage Trip Amps Product Number
Standard Frames Three-Phase, Four-Wire TED6
600 Volts Inter. Trip 400 AC440JK6G
Voltage Trip Amps Product Number
600 Volts Inter. Trip 450 AC445JK6G
600 Volts Fixed Trip 15 AC41ED6G 600 Volts Inter. Trip 500 AC450JK6G
600 Volts Fixed Trip 20 AC42ED6G 600 Volts Inter. Trip 600 AC460JK6G
600 Volts Fixed Trip 30 AC43ED6G
600 Volts Fixed Trip 40 AC44ED6G
600 Volts Fixed Trip 50 AC45ED6G
600 Volts Fixed Trip 70 AC47ED6G Standard Frames Three-Phase, Four-Wire TKM8

ETE
600 Volts Fixed Trip 100 AC410ED6G Voltage Trip Amps Product Number
600 Volts Inter. Trip 300 AC430KMG

Standard Frames Three-Phase, Four-Wire TFJ


600 Volts Inter. Trip
600 Volts Inter. Trip

S O L
400
500
AC440KMG
AC450KMG

OB
600 Volts Inter. Trip 600 AC460KMG
Voltage
600 Volts Fixed Trip
Trip Amps
70

E T E Product Number
AC47FJG
600 Volts Inter. Trip
600 Volts Inter. Trip
700
800
AC470KMG
AC480KMG
600 Volts Fixed Trip
600 Volts Fixed Trip

S O
100
110
L AC410FJG
AC411FJG
600 Volts Fixed Trip
600 Volts Fixed Trip
600 Volts Fixed Trip
600 Volts Fixed Trip O B 125
150
200
225
AC412FJG
AC415FJG
AC420FJG
AC422FJG

Standard Frames Three-Phase, Four-Wire TFK


Voltage Trip Amps

E T E Product Number
600 Volts Inter. Trip
600 Volts Inter. Trip

S O
70
100
L AC47FKG
AC410FKG

B
600 Volts Inter. Trip 125 AC412FKG

O
600 Volts Inter. Trip 150 AC415FKG
600 Volts Inter. Trip 200 AC420FKG
600 Volts Inter. Trip 225 AC422FKG

Rev. 11/13 www.geindustrial.com BuyLog Catalog 13-83


Data subject to change
without notice
Busway Section 13
Armor-Clad Busway
Busway Plugs

Hi-Break Frames Three-Phase, Three-Wire THED Hi-Break Frames Three-Phase, Four-Wire THED
Voltage Trip Amps Product Number Voltage Trip Amps Product Number
600 Volts Fixed Trip 15 AC31HEDG 600 Volts Fixed Trip 15 AC41HEDG
600 Volts Fixed Trip 20 AC32HEDG 600 Volts Fixed Trip 20 AC42HEDG
600 Volts Fixed Trip 30 AC33HEDG 600 Volts Fixed Trip 30 AC43HEDG
600 Volts Fixed Trip 40 AC34HEDG 600 Volts Fixed Trip 40 AC44HEDG
600 Volts Fixed Trip 50 AC35HEDG 600 Volts Fixed Trip 50 AC45HEDG
600 Volts Fixed Trip 70 AC37HEDG 600 Volts Fixed Trip 70 AC47HEDG
600 Volts Fixed Trip 100 AC310HEDG 600 Volts Fixed Trip 100 AC410HEDG

Hi-Break Frames Three-Phase, Three-Wire THFK Hi-Break Frames Three-Phase, Four-Wire THFK

ETE ETE
Voltage Trip Amps Product Number Voltage Trip Amps Product Number

L L
600 Volts Inter. Trip 70 AC37HFKG 600 Volts Inter. Trip 70 AC47HFKG

O O
600 Volts Inter. Trip 100 AC310HFKG 600 Volts Inter. Trip 100 AC410HFKG

BS BS
600 Volts Inter. Trip 125 AC312HFKG 600 Volts Inter. Trip 125 AC412HFKG
600 Volts Inter. Trip 150 AC315HFKG 600 Volts Inter. Trip 150 AC415HFKG
600 Volts Inter. Trip
600 Volts Inter. Trip
O 200
225
AC320HFKG
AC322HFKG
600 Volts Inter. Trip
600 Volts Inter. Trip
O 200
225
AC420HFKG
AC422HFKG

Hi-Break Frames Three-Phase, Three-Wire THJK4 Hi-Break Frames Three-Phase, Four-Wire THJK4
Voltage Trip Amps Product Number Voltage Trip Amps Product Number
600 Volts Inter. Trip 125 AC312HJK4G 600 Volts Inter. Trip 125 AC412HJK4G
600 Volts Inter. Trip 150 AC315HJK4G 600 Volts Inter. Trip 150 AC415HJK4G
600 Volts Inter. Trip 200 AC320HJK4G 600 Volts Inter. Trip 200 AC420HJK4G
600 Volts Inter. Trip 225 AC322HJK4G 600 Volts Inter. Trip 225 AC422HJK4G
600 Volts Inter. Trip 300 AC330HJK4G 600 Volts Inter. Trip 300 AC430HJK4G
600 Volts Inter. Trip 400 AC340HJK4G 600 Volts Inter. Trip 400 AC440HJK4G

Hi-Break Frames Three-Phase, Three-Wire THJK6 Hi-Break Frames Three-Phase, Four-Wire THJK6
Voltage Trip Amps Product Number Voltage Trip Amps Product Number
600 Volts Inter. Trip 400 AC340HJK6G 600 Volts Inter. Trip 400 AC440HJK6G
600 Volts Inter. Trip 450 AC345HJK6G 600 Volts Inter. Trip 450 AC445HJK6G
600 Volts Inter. Trip 500 AC350HJK6G 600 Volts Inter. Trip 500 AC450HJK6G
600 Volts Inter. Trip 600 AC360HJK6G 600 Volts Inter. Trip 600 AC460HJK6G

Hi-Break Frames Three-Phase, Three-Wire THKM8 Hi-Break Frames Three-Phase, Four-Wire THKM8

ETE ETE
Voltage Trip Amps Product Number Voltage Trip Amps Product Number

L L
600 Volts Inter. Trip 300 AC330HKMG 600 Volts Inter. Trip 300 AC430HKMG
600 Volts Inter. Trip
600 Volts Inter. Trip

S O 400
500
AC340HKMG
AC350HKMG
600 Volts Inter. Trip
600 Volts Inter. Trip

S O400
500
AC440HKMG
AC450HKMG

OB OB
600 Volts Inter. Trip 600 AC360HKMG 600 Volts Inter. Trip 600 AC460HKMG
600 Volts Inter. Trip 700 AC370HKMG 600 Volts Inter. Trip 700 AC470HKMG
600 Volts Inter. Trip 800 AC380HKMG 600 Volts Inter. Trip 800 AC480HKMG

13-84 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Busway Section 13
Armor-Clad Busway
Busway Plugs

High Interrupting Spectra RMS Circuit Breaker High Interrupting Spectra RMS Circuit Breaker
Three-Phase, Three-Wire SELA Three-Phase, Four-Wire SELA
Short Circuit Short Circuit Short Circuit Short Circuit Short Circuit Short Circuit
Rating @ 240V Rating @ 480V Rating @ 600V Trip Product Rating @ 240V Rating @ 480V Rating @ 600V Trip Product
(kAIC) (kAIC) (kAIC) Amps Number (kAIC) (kAIC) (kAIC) Amps Number
100 65 25 15 AC31SELG 100 65 25 15 AC41SELG
100 65 25 20 AC32SELG 100 65 25 20 AC42SELG
100 65 25 30 AC33SELG 100 65 25 30 AC43SELG
100 65 25 40 AC34SELG 100 65 25 40 AC44SELG
100 65 25 50 AC35SELG 100 65 25 50 AC45SELG
100 65 25 60 AC36SELG 100 65 25 60 AC46SELG
100 65 25 70 AC37SELG 100 65 25 70 AC47SELG
100 65 25 80 AC38SELG 100 65 25 80 AC48SELG
100 65 25 90 AC39SELG 100 65 25 90 AC49SELG
100 65 25 100 AC310SELG 100 65 25 100 AC410SELG
100 65 25 110 AC311SELG 100 65 25 110 AC411SELG
100 65 25 125 AC312SELG 100 65 25 125 AC412SELG
100 65 25 150 AC315SELG 100 65 25 150 AC415SELG

IC rating in rms symmetrical kA. IC rating in rms symmetrical kA.

High Interrupting Spectra RMS Circuit Breaker High Interrupting Spectra RMS Circuit Breaker
Three-Phase, Three-Wire SFLA Three-Phase, Four-Wire SFLA
Short Circuit Short Circuit Short Circuit Short Circuit Short Circuit Short Circuit
Rating @ 240V Rating @ 480V Rating @ 600V Trip Product Rating @ 240V Rating @ 480V Rating @ 600V Trip Product
(kAIC) (kAIC) (kAIC) Amps Number (kAIC) (kAIC) (kAIC) Amps Number
100 65 25 70 AC37SFLG 100 65 25 70 AC47SFLG
100 65 25 90 AC39SFLG 100 65 25 90 AC49SFLG
100 65 25 100 AC310SFLG 100 65 25 100 AC410SFLG
100 65 25 110 AC311SFLG 100 65 25 110 AC411SFLG
100 65 25 125 AC312SFLG 100 65 25 125 AC412SFLG
100 65 25 150 AC315SFLG 100 65 25 150 AC415SFLG
100 65 25 175 AC317SFLG 100 65 25 175 AC417SFLG
100 65 25 200 AC320SFLG 100 65 25 200 AC420SFLG
100 65 25 225 AC322SFLG 100 65 25 225 AC422SFLG
100 65 25 250 AC325SFLG 100 65 25 250 AC425SFLG

IC rating in rms symmetrical kA. IC rating in rms symmetrical kA.


NOTE: Armor-Clad Busway Plugs have the same dimensions as Spectra-Series
Plugs. Refer to page 13-35.

Rev. 11/13 www.geindustrial.com BuyLog Catalog 13-85


Data subject to change
without notice
Busway Section 13
Armor-Clad Busway
Busway Plugs

Tri-Break Three-Phase, Three-Wire TB1


Voltage Trip Amps

E Product Number
Tri-Break Three-Phase, Four-Wire TB6
Voltage

E T
Trip Amps E Product Number
600 Volts Fixed Trip 15

OL E T AC31B1E05G 600 Volts Inter. Trip

OL
300 AC430B6J14G

OBS
600 Volts Fixed Trip 20 AC32B1E05G 600 Volts Inter. Trip 400 AC440B6J14G

OBS
600 Volts Fixed Trip 30 AC33B1E05G 600 Volts Inter. Trip 500 AC450B6J14G
600 Volts Fixed Trip 40 AC34B1E05G 600 Volts Inter. Trip 600 AC460B6J14G
600 Volts Fixed Trip 50 AC35B1E09G
600 Volts Fixed Trip 70 AC37B1E09G
600 Volts Fixed Trip 100 AC310B1E09G
Tri-Break Three-Phase, Four-Wire TB8

E T E
OL
Voltage Trip Amps Product Number

OBS
Tri-Break Three-Phase, Three-Wire TB4 600 Volts Inter. Trip 600 AC460B8K22G

Voltage Trip Amps

E T E
Product Number
600 Volts Inter. Trip
600 Volts Inter. Trip
700
800
AC470B8K22G
AC480B8K22G
600 Volts Inter. Trip
600 Volts Inter. Trip

S O
125
150
L AC312B4F14G
AC315B4F14G

B
600 Volts Inter. Trip 200 AC320B4F14G
Switch-Operated Fusible Plugs Three-Phase, Three-Wire

O
600 Volts Inter. Trip 225 AC322B4F14G
600 Volts Inter. Trip 300 AC330B4F14G Voltage Trip Amps Product Number
600 Volts Inter. Trip 400 AC340B4F14G
240 30 AC321RG
240 60 AC322RG
240 100 AC323RG
Tri-Break Three-Phase, Three-Wire TB6
E
240 200 AC324RG

Voltage Trip Amps

L E TProduct Number
240
240
400
600
AC325RG
AC326RG

O
600 Volts Inter. Trip 300 AC330B6J14G 480 or 600 30 AC361RG
600 Volts Inter. Trip
600 Volts Inter. Trip
600 Volts Inter. Trip

O B S 400
500
600
AC340B6J14G
AC350B6J14G
AC360B6J14G
480 or 600
480 or 600
480 or 600
480 or 600
60
100
200
400
AC362RG
AC363RG
AC364RG
AC365RG
480 or 600 600 AC366RG

ETE
Tri-Break Three-Phase, Three-Wire TB8 With QMR Interrupter Fuses Not Included

SOL
Voltage Trip Amps Product Number
600 Volts Inter. Trip 600 AC360B8K22G
Switch-Operated Fusible Plugs Three-Phase, Four-Wire

OB
600 Volts Inter. Trip 700 AC370B8K22G
600 Volts Inter. Trip 800 AC380B8K22G Voltage Trip Amps Product Number
240 30 AC421RG
240 60 AC422RG
Tri-Break Three-Phase, Four-Wire TB1 240 100 AC423RG
240 200 AC424RG
Voltage
600 Volts Fixed Trip
Trip Amps
15

E T E Product Number
AC41B1E05G
240
240
400
600
AC425RG
AC426RG

OL
600 Volts Fixed Trip 20 AC42B1E05G 480 or 600 30 AC461RG

OBS
600 Volts Fixed Trip 30 AC43B1E05G 480 or 600 60 AC462RG
600 Volts Fixed Trip 40 AC44B1E05G 480 or 600 100 AC463RG
600 Volts Fixed Trip 50 AC45B1E09G 480 or 600 200 AC464RG
600 Volts Fixed Trip 70 AC47B1E09G 480 or 600 400 AC465RG
600 Volts Fixed Trip 100 AC410B1E09G 480 or 600 600 AC466RG

With QMR Interrupter Fuses Not Included


Additional options for Fusible Plugs are found on page 13-87.
Tri-Break Three-Phase, Four-Wire TB4

ETE
Voltage Trip Amps Product Number
600 Volts Inter. Trip
600 Volts Inter. Trip
600 Volts Inter. Trip
S O L
125
150
200
AC412B4F14G
AC415B4F14G
AC420B4F14G

OB
600 Volts Inter. Trip 225 AC422B4F14G
600 Volts Inter. Trip 300 AC430B4F14G
600 Volts Inter. Trip 400 AC440B4F14G

13-86 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Busway Section 13
Armor-Clad Busway
Plugs and Protective Devices
Options and Additions

Enclosure Only Contactor PlugsAdd to required protective


Three-Phase, Three-Wire Ground Standard

E T E device bus plug

OL
Voltage Trip Amps Product Number Ampere Rating Type
E 100 max. AC3100EG1 30 Electrically Held
F

O B S 225 AC3225FG1
1Not for Spectra breakers. E and F frame enclosures for standard molded case
circuit breakers only.
60
100
30
60
Electrically Held
Electrically Held
Mechanically Held
Mechanically Held
(Order circuit breaker from Section 6.) 100 Mechanically Held
30 Pilot Light
60 Pilot Light

E
100 Pilot Light
Enclosure Only Three-Phase, Four-Wire Ground Standard
Voltage Trip Amps

E T Product Number
30
60
Pushbutton or Selector Switch
Pushbutton or Selector Switch

OL
100 Pushbutton or Selector Switch
E 100 max. AC4100EG1

OBS
30 Control Transformer2
F 225 AC4225FG1
60 Control Transformer2
1Not for Spectra breakers. E and F frame enclosures for standard molded case 100 Control Transformer2
circuit breakers only. 30 Extra Interlock
(Order circuit breaker from Section 6.) 60 Extra Interlock
100 Extra Interlock
30 Two-wire Control

Ground Dector Plugs Three-Phase, Three-Wire


E T E 60
100
Two-wire Control
Two-wire Control

OL
Voltage Product Number 30 Auxiliary Contact
60 Auxiliary Contact

OBS
208-240 AC321N 100 Auxiliary Contact
440-600 AC361N
2Includes one secondary fuse.
Not UL Listed

Options for Fusible Switch Units Use for Armor-Clad Busway


Adapter Kits
UL Listed
Voltage Trip Amps Product Number Ampere Rating Description
Convert Armor-Clad 30-100 ACSB1G Factory installed Class R fuse clips;
Plugs to Spectra Bus 30 add suffix "R" to Product Number
Convert Armor-Clad 200-225 ACSB4G Factory installed Class R fuse clips;
Plugs to Spectra Bus 60 add suffix "R" to Product Number
Convert Armor-Clad 400-800 ACSB5G Factory installed Class R fuse clips;
Plugs to Spectra Bus 100 add suffix "R" to Product Number
Factory installed Class R fuse clips;
(Style 7 and 8 shipped after 1/91.) Ground stabs included.
200 add suffix "R" to Product Number
Factory installed Class R fuse clips;
400 add suffix "R" to Product Number
Miscellaneous Modifications Factory installed Class R fuse clips;
600 add suffix "R" to Product Number
Plug Assist - Standard for plugs over 100 amperes. Add suffix P Factory installed Class J fuse clips;
to the product number for plugs 100 amperes and below. 30 add suffix "J" to 600 V plug Product Number
Factory installed Class J fuse clips;
60 add suffix "J" to 600 V plug Product Number
Factory installed Class J fuse clips;
100 add suffix "J" to 600 V plug Product Number
Factory installed Class J fuse clips;
200 add suffix "J" to 600 V plug Product Number
Factory installed Class J fuse clips;
400 add suffix "J" to 600 V plug Product Number
Factory installed Class J fuse clips;
600 add suffix "J" to 600 V plug Product Number
QMW in lieu of QMR;
30 change "R" in Product Number to "W"
QMW in lieu of QMR;
60 change "R" in Product Number to "W"
QMW in lieu of QMR;
100 change "R" in Product Number to "W"
QMW in lieu of QMR;
200 change "R" in Product Number to "W"
QMW in lieu of QMR;
400 change "R" in Product Number to "W"
QMW in lieu of QMR;
600 change "R" in Product Number to "W"

Rev. 11/13 www.geindustrial.com BuyLog Catalog 13-87


Data subject to change
without notice
Busway Section 13
Flex-A-Power Busway
Types FVA, FVK and LVDP
Application

Types FVA and FVK Busway Aluminum Bus for Type FVA 800 Amps Three-Phase,
Types FVA and FVK Flex-A-Power
busway are obsolete for new Three-Wire, or Three-Wire, DC 600 Volts
manufacture. Only end boxes and cable tap boxes are available. Component Type Product Number
Accessories End Box DASKEB310
Accessories Cable Tap Box DAACB381
Aluminum Bus for Type FVA 225 Amps Three-Phase, 1Center cable tap box. For end cable tap box, order this tap box plus an end box.

Three-Wire, or Three-Wire, DC 600 Volts


Component Type Product Number
Accessories End Box DASKEB34
Aluminum Bus for Type FVA 225 Amps Three-Phase,
Accessories Cable Tap Box DAACB321 Four-Wire 480 Y/277 or 208 Y/120 Volts, Half Capacity Neutral
1Center cable tap box. For end cable tap box, order this tap box plus an end box. Component Type Product Number
Accessories End Box DASKEBN134A
Accessories Cable Tap Box DAACBN132A1
Aluminum Bus for Type FVA 400 Amps Three-Phase, 1Center cable tap box. For end cable tap box, order this tap box plus an end box.

Three-Wire, or Three-Wire, DC 600 Volts


Component Type Product Number
Accessories End Box DASKEB36
Aluminum Bus for Type FVA 400 Amps Three-Phase,
Accessories Cable Tap Box DAACB341 Four-Wire 480 Y/277 or 208 Y/120 Volts, Half Capacity Neutral
1Center cable tap box. For end cable tap box, order this tap box plus an end box. Component Type Product Number
Accessories End Box DASKEBN136A
Accessories Cable Tap Box DAACBN1341
Aluminum Bus for Type FVA 600 Amps Three-Phase, 1Center cable tap box. For end cable tap box, order this tap box plus an end box.

Three-Wire, or Three-Wire, DC 600 Volts


Component Type Product Number
Accessories End Box DASKEB310
Accessories Cable Tap Box DAACB361
1Center cable tap box. For end cable tap box, order this tap box plus an end box.

13-88 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Busway Section 13
Flex-A-Power Busway (continued)
Types FVA, FVK and LVDP
Application

Aluminum Bus for Type FVA 600 Amps Three-Phase, Copper Bus for Type FVK 600 Amps Three-Phase,
Four-Wire 480 Y/277 or 208 Y/120 Volts, Half Capacity Neutral Three-Wire, or Three-Wire, DC 600 Volts
Component Type Product Number Component Type Product Number
Accessories End Box DASKEBN1310A Accessories End Box DASKEB36
Accessories Cable Tap Box DAACBN1361 Accessories Cable Tap Box DAKCB361
1Center cable tap box. For end cable tap box, order this tap box plus an end box. 1Center cable tap box. For end cable tap box, order this tap box plus an end box.

Aluminum Bus for Type FVA 800 Amps Three-Phase, Copper Bus for Type FVK 800 Amps Three-Phase,
Four-Wire 480 Y/277 or 208 Y/120 Volts, Half Capacity Neutral Three-Wire, or Three-Wire, DC 600 Volts
Component Type Product Number Component Type Product Number
Accessories End Box DASKEBN1310A Accessories End Box DASKEB310
Accessories Cable Tap Box DAACBN1381 Accessories Cable Tap Box DAKCB3101
1Center cable tap box. For end cable tap box, order this tap box plus an end box. 1Center cable tap box. For end cable tap box, order this tap box plus an end box.

Copper Bus for Type FVK 225 Amps Three-Phase, Copper Bus for Type FVK 1000 Amps Three-Phase,
Three-Wire, or Three-Wire, DC 600 Volts Three-Wire, or Three-Wire, DC 600 Volts
Component Type Product Number Component Type Product Number
Accessories End Box DASKEB34 Accessories End Box DASKEB310
Accessories Cable Tap Box DAKCB321 Accessories Cable Tap Box DAKCB3101
1Center cable tap box. For end cable tap box, order this tap box plus an end box. 1Center cable tap box. For end cable tap box, price and order this tap box plus an
end box.

Copper Bus for Type FVK 400 Amps Three-Phase,


Three-Wire, or Three-Wire, DC 600 Volts
Component Type Product Number
Accessories End Box DASKEB34
Accessories Cable Tap Box DAKCB34B1
1Center cable tap box. For end cable tap box, order this tap box plus an end box.

Rev. 11/13 www.geindustrial.com BuyLog Catalog 13-89


Data subject to change
without notice
Busway Section 13
Flex-A-Power Busway (continued)
Types FVA, FVK and LVDP
Application and Product Number Pricing

Copper Bus for Type FVK 225 Amps Three-Phase, Copper Bus for Type FVK 1000 Amps Three-Phase,
Four-Wire 480 Y/277 or 208 Y/120 Volts, Half Capacity Neutral Four-Wire 480 Y/277 or 208 Y/120 Volts, Half Capacity Neutral
Component Type Product Number Component Type Product Number
Accessories End Box DASKEBN134A Accessories End Box DASKEBN1310A
Accessories Cable Tap Box DAKCBN132A1 Accessories Cable Tap Box DAKCBN1310A1
1Center cable tap box. For end cable tap box, order this tap box plus an end box. 1Center cable tap box. For end cable tap box, order this tap box plus an end box.

Copper Bus for Type FVK 400 AmpsThree-Phase, Fusible PlugsType QMR Three-Phase, Three-Wire
Four-Wire 480 Y/277 or 208 Y/120 Volts, Half Capacity Neutral Component Voltage Product Number

Component Type Product Number 30 240 FVK321R


60 240 FVK322R
Accessories End Box DASKEBN134A
100 240 FVK323R
Accessories Cable Tap Box DAKCBN134A1
200 240 FVK324R
1Center cable tap box. For end cable tap box, order this tap box plus an end box. 400 240 FVK325RT4
600 240 FVK326R3
30 600 FVK361R
60 600 FVK362R
Copper Bus for Type FVK 600 Amps Three-Phase, 100 600 FVK363R
Four-Wire 480 Y/277 or 208 Y/120 Volts, Half Capacity Neutral 200 600 FVK364R
400 600 FVK365RT4
Component Type Product Number 600 600 FVK366R3
Accessories End Box DASKEBN136A
Externally Operated with Class H Fuse Clips. Fuses Not Included. To add Class R or
Accessories Cable Tap Box DAKCBN136A1
Class J fuse provisions, see page 13-93.
1Center cable tap box. For end cable tap box, order this tap box plus an end box. 3Special hanger required on LVDP. Furnish nameplate data and see extension pan
table. See page 13-93.
4T suffix on product number indicates 2(200A) switches used to make up a 400A

Copper Bus for Type FVK 800 Amps Three-Phase, requirement.

Four-Wire 480 Y/277 or 208 Y/120 Volts, Half Capacity Neutral


Component Type Product Number
Fusible PlugsType QMR Three-Phase, Four-Wire
Accessories End Box DASKEBN1310A
Component Voltage Product Number
Accessories Cable Tap Box DAKCBN1310A1
1Center cable tap box. For end cable tap box, order this tap box plus an end box. 30 240 FVK421R
60 240 FVK422R
100 240 FVK423R
200 240 FVK424R
400 240 FVK425RT4
600 240 FVK426R3
30 480 FVK461R
60 480 FVK462R
100 480 FVK463R
200 480 FVK464R
400 480 FVK465RT4
600 480 FVK466R3

Externally Operated with Class H Fuse Clips. Fuses Not Included. To add Class R or
Class J fuse provisions, see page 13-93.
3Special hanger required on LVDP. Furnish nameplate data and see extension pan
table. See page 13-93.
4T suffix on product number indicates 2(200A) switches used to make up a 400A
requirement.

Ground Detector Plugs Three-Phase, Three-Wire

Component Voltage Product Number


GN 208-240 DAGN32
GN 440-600 DAGN36

(Not UL listed)

13-90 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Busway Section 13
Flex-A-Power Busway
Types FVA, FVK and LVDP
Busway Plugs

Circuit Breakers - Standard Frames Three-Phase, Circuit Breakers - Standard Frames Three-Phase,
Three-Wire TEB Three-Wire TK4V
Voltage Trip Amps Product Number Voltage Trip Amps Product Number
240 Volts Fixed Trip 15 FVK31EB 600 Volts 300 FVK330KM
240 Volts Fixed Trip 20 FVK32EB 600 Volts 400 FVK340KM
240 Volts Fixed Trip 30 FVK33EB 600 Volts 500 FVK350KM
240 Volts Fixed Trip 40 FVK34EB 600 Volts 600 FVK360KM
240 Volts Fixed Trip 50 FVK35EB 600 Volts 700 FVK370KM
240 Volts Fixed Trip 70 FVK37EB 600 Volts 800 FVK380KM
240 Volts Fixed Trip 100 FVK310EB

Circuit Breakers - Standard Frames Three-Phase,


Circuit Breakers - Standard Frames Three-Phase, Four-Wire TEB
Three-Wire TED4 Voltage Trip Amps Product Number
Voltage Trip Amps Product Number
240 Volts Fixed Trip 15 FVK41EB
480 Volts Fixed Trip 15 FVK31ED4 240 Volts Fixed Trip 20 FVK42EB
480 Volts Fixed Trip 20 FVK32ED4 240 Volts Fixed Trip 30 FVK43EB
480 Volts Fixed Trip 30 FVK33ED4 240 Volts Fixed Trip 40 FVK44EB
480 Volts Fixed Trip 40 FVK34ED4 240 Volts Fixed Trip 50 FVK45EB
480 Volts Fixed Trip 50 FVK35ED4 240 Volts Fixed Trip 70 FVK47EB
480 Volts Fixed Trip 70 FVK37ED4 240 Volts Fixed Trip 100 FVK410EB
480 Volts Fixed Trip 100 FVK310ED4

Circuit Breakers - Standard Frames Three-Phase,


Circuit Breakers - Standard Frames Three-Phase, Four-Wire TED4
Three-Wire TED6 Voltage Trip Amps Product Number
Voltage Trip Amps Product Number
480 Volts Fixed Trip 15 FVK41ED4
600 Volts Fixed Trip 15 FVK31ED6 480 Volts Fixed Trip 20 FVK42ED4
600 Volts Fixed Trip 20 FVK32ED6 480 Volts Fixed Trip 30 FVK43ED4
600 Volts Fixed Trip 30 FVK33ED6 480 Volts Fixed Trip 40 FVK44ED4
600 Volts Fixed Trip 40 FVK34ED6 480 Volts Fixed Trip 50 FVK45ED4
600 Volts Fixed Trip 50 FVK35ED6 480 Volts Fixed Trip 70 FVK47ED4
600 Volts Fixed Trip 70 FVK37ED6 480 Volts Fixed Trip 100 FVK410ED4
600 Volts Fixed Trip 100 FVK310ED6

Circuit Breakers - Standard Frames Three-Phase,


Circuit Breakers - Standard Frames Three-Phase, Four-Wire TED6
Three-Wire TFK
Not Available
Voltage Trip Amps Product Number
600 Volts Inter. Trip 70 FVK37FK
600 Volts Inter. Trip 100 FVK310FK
600 Volts Inter. Trip 125 FVK312FK
Circuit Breakers - Standard Frames Three-Phase,
600 Volts Inter. Trip 150 FVK315FK Four-Wire TFK
600 Volts Inter. Trip 200 FVK320FK
Voltage Trip Amps Product Number
600 Volts Inter. Trip 225 FVK322FK
600 Volts Inter. Trip 70 FVK47FK
600 Volts Inter. Trip 100 FVK410FK
600 Volts Inter. Trip 125 FVK412FK
Circuit Breakers - Standard Frames Three-Phase, 600 Volts Inter. Trip 150 FVK415FK
Three-Wire TJK4 600 Volts Inter. Trip 200 FVK420FK
600 Volts Inter. Trip 225 FVK422FK
Voltage Trip Amps Product Number
600 Volts Inter. Trip 125 FVK312JK
600 Volts Inter. Trip 150 FVK315JK
600 Volts Inter. Trip 200 FVK320JK
600 Volts Inter. Trip 225 FVK322JK
600 Volts Inter. Trip 300 FVK330JK
600 Volts Inter. Trip 400 FVK340JK

Rev. 11/13 www.geindustrial.com BuyLog Catalog 13-91


Data subject to change
without notice
Busway Section 13
Flex-A-Power Busway (continued)
Types FVA, FVK and LVDP
Busway Plugs

Circuit BreakersStandard Frames Circuit BreakersHi-Break Frames1 Three-Phase,


Three-Phase, Four-Wire TJK4 Three-Wire THKM8
Voltage Trip Amps Product Number Voltage Trip Amps Product Number
600 Volts Inter. Trip 125 FVK412JK 600 Volts Inter. Trip 300 FVK330HKM
600 Volts Inter. Trip 150 FVK415JK 600 Volts Inter. Trip 400 FVK340HKM
600 Volts Inter. Trip 200 FVK420JK 600 Volts Inter. Trip 500 FVK350HKM
600 Volts Inter. Trip 225 FVK422JK 600 Volts Inter. Trip 600 FVK360HKM
600 Volts Inter. Trip 300 FVK430JK 600 Volts Inter. Trip 700 FVK370HKM
600 Volts Inter. Trip 400 FVK440JK 600 Volts Inter. Trip 800 FVK380HKM

Circuit BreakersStandard Frames Three-Phase, Circuit BreakersHi-Break Frames1 Three-Phase,


Four-Wire TK4V Four-Wire THED
Voltage Trip Amps Product Number Voltage Trip Amps Product Number
600 Volts 300 FVK430KM 600 Volts Fixed Trip 15 FVK41HED
600 Volts 400 FVK440KM 600 Volts Fixed Trip 20 FVK42HED
600 Volts 500 FVK450KM 600 Volts Fixed Trip 30 FVK43HED
600 Volts 600 FVK460KM 600 Volts Fixed Trip 40 FVK44HED
600 Volts 700 FVK470KM 600 Volts Fixed Trip 50 FVK45HED
600 Volts 800 FVK480KM 600 Volts Fixed Trip 70 FVK47HED
600 Volts Fixed Trip 100 FVK410HED

Circuit BreakersHi-Break Frames1 Three-Phase,


Three-Wire THED Circuit BreakersHi-Break Frames1 Three-Phase,
Voltage Trip Amps Product Number
Four-Wire THFK
Voltage Trip Amps Product Number
600 Volts Fixed Trip 15 FVK31HED
600 Volts Fixed Trip 20 FVK32HED 600 Volts Inter. Trip 70 FVK47HFK
600 Volts Fixed Trip 30 FVK33HED 600 Volts Inter. Trip 100 FVK410HFK
600 Volts Fixed Trip 40 FVK34HED 600 Volts Inter. Trip 125 FVK412HFK
600 Volts Fixed Trip 50 FVK35HED 600 Volts Inter. Trip 150 FVK415HFK
600 Volts Fixed Trip 70 FVK37HED 600 Volts Inter. Trip 200 FVK420HFK
600 Volts Fixed Trip 100 FVK310HED 600 Volts Inter. Trip 225 FVK422HFK

Circuit BreakersHi-Break Frames1 Three-Phase, Circuit BreakersHi-Break Frames1 Three-Phase,


Three-Wire THFK Four-Wire THJK4
Voltage Trip Amps Product Number Voltage Trip Amps Product Number
600 Volts Inter. Trip 70 FVK37HFK 600 Volts Inter. Trip 125 FVK412HJK
600 Volts Inter. Trip 100 FVK310HFK 600 Volts Inter. Trip 150 FVK415HJK
600 Volts Inter. Trip 125 FVK312HFK 600 Volts Inter. Trip 200 FVK420HJK
600 Volts Inter. Trip 150 FVK315HFK 600 Volts Inter. Trip 225 FVK422HJK
600 Volts Inter. Trip 200 FVK320HFK 600 Volts Inter. Trip 300 FVK430HJK
600 Volts Inter. Trip 225 FVK322HFK 600 Volts Inter. Trip 400 FVK440HJK

Circuit BreakersHi-Break Frames1 Three-Phase, Circuit BreakersHi-Break Frames1 Three-Phase,


Three-Wire THJK4 Four-Wire THKM8
Voltage Trip Amps Product Number Voltage Trip Amps Product Number
600 Volts Inter. Trip 125 FVK312HJK 600 Volts Inter. Trip 300 FVK430HKM
600 Volts Inter. Trip 150 FVK315HJK 600 Volts Inter. Trip 400 FVK440HKM
600 Volts Inter. Trip 200 FVK320HJK 600 Volts Inter. Trip 500 FVK450HKM
600 Volts Inter. Trip 225 FVK322HJK 600 Volts Inter. Trip 600 FVK460HKM
600 Volts Inter. Trip 300 FVK330HJK 600 Volts Inter. Trip 700 FVK470HKM
600 Volts Inter. Trip 400 FVK340HJK 600 Volts Inter. Trip 800 FVK480HKM
1Special hanger required for all plugs except those with TEB, TED4, TED6, and THED
frames when mounted on LVDP busway. Furnish complete LVDP busway name-
plate data when ordering.

13-92 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Busway Section 13
Flex-A-Power Busway (continued)
Types FVA, FVK and LVDP
Busway Plugs

Enclosure Only Three-Phase, Three-Wire Extension Pansor LVDP Busway Plugs


Frame Type Amperage Product Number Select Busway Plugs then order Extension Pans from table.
E 100 FVK3100E No charge when ordering with plug.
F 225 FVK3225F

Breaker shipped separately for field assembly. Flex-A-Plug Extension Pan


Prefix Suffix Ampere Rating Product Number
FVK R, RT 30-400 None
FVK R, RT 600 DFIPPKM
Enclosure Only Three-Phase, Four-Wire FVK EB, ED4, ED6, HED 15-150 None
Frame Type Amperage Product Number FVK FJ, FK, HFK 70-225 None
FVK JJ, JK, HLK 125-400 DF1PPJ
E 100 FVK4100E
FVK KM, HKM 125-800 DF1PPKM
F 225 FVK4225F

Breaker shipped separately for field assembly.

Options for Fusible Switch Units Use for FVK


UL Listed
Ampere Rating Description
Factory installed Class R fuse clips;
30 add "R" suffix to Product Number
Factory installed Class R fuse clips;
60 add "R" suffix to Product Number
Factory installed Class R fuse clips;
100 add "R" suffix to Product Number
Factory installed Class R fuse clips;
200 add "R" suffix to Product Number
Factory installed Class R fuse clips;
400 add "R" suffix to Product Number
Factory installed Class R fuse clips;
600 add "R" suffix to Product Number
Factory installed Class J fuse clips;
30 add "J" suffix to 600 V plug Product Number
Factory installed Class J fuse clips;
60 add "J" suffix to 600 V plug Product Number
Factory installed Class J fuse clips;
100 add "J" suffix to 600 V plug Product Number
Factory installed Class J fuse clips;
200 add "J" suffix to 600 V plug Product Number
Factory installed Class J fuse clips;
400 add "J" suffix to 600 V plug Product Number
Factory installed Class J fuse clips;
600 add "J" suffix to 600 V plug Product Number1
QMW in lieu of QMR;
30 change "R" in Product Number to "W"
QMW in lieu of QMR;
60 change "R" in Product Number to "W"
QMW in lieu of QMR;
100 change "R" in Product Number to "W"
QMW in lieu of QMR;
200 change "R" in Product Number to "W"
QMW in lieu of QMR;
400 change "R" in Product Number to "W"
QMW in lieu of QMR;
600 change "R" in Product Number to "W"
1Not UL listed.

Rev. 11/13 www.geindustrial.com BuyLog Catalog 13-93


Data subject to change
without notice
Busway Section 13
Flex-A-Power Busway
Types FVA, FVK and LVDP
Outlines and Dimensions

Hanger Dimensions
With Aluminum Bus Bars
Housing Hanger Hanger Hanger
Amperage Depth (in.) Dimension A (in.) Dimension B (in.) Dimension C (in.)
225 Amps 3.19 4.69 1.88 2.5
400 Amps 4.19 5.19 1.88 2.56
600 Amps 6.19 6.19 1.63 3.81
800 Amps 6.19 6.19 1.63 3.81

Hanger Dimensions Hanger Dimensions


With Copper Bus Bars
Housing Hanger Hanger Hanger
Amperage Depth (in.) Dimension A (in.) Dimension B (in.) Dimension C (in.)
225 Amps 3.19 4.69 1.44 2.5
400 Amps 3.19 4.69 1.44 2.5
600 Amps 4.19 5.19 1.88 2.56
800 Amps 6.19 6.19 1.63 3.81
1000 Amps 6.19 6.19 1.63 3.81

Cable Tap Boxes - Dimensions


No. of #2-600kcmil
Amperage Dimension A Dimension B Dimension C Lugs/ N & GRD
End-of-run cable tap box. For center
(joint) cable tap box omit the end box.
225 Amps 6 32 16 1,1
400 Amps 6 32 16 1,1
600 Amps1 6 32 16 1,2
800 Amps2 8 52 20 2,3
1000 Amps2 8 52 20 2,3
1For FVA, use 800 amp dimensions.
2No knockouts in this box.

End Boxes - Dimensions


Amperage Conductor Material Dimension D
225 Amps, 400 Amps Copper 3.19 End box used to close off end-of-run.
600 Amps Copper 4.19
800 Amps, 1000 Amps Copper 6.19
225 Amps Aluminum 3.19
400 Amps Aluminum 4.19
600 Amps, 800 Amps Aluminum 6.19

Standard lengths, three-wire systems,


600 volts maximum.

Standard lengths, three-phase,


four-wire systems, 480 Y/277 Volts

13-94 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Busway Section 13
Type DE Busway
Distribution Equipment
Busway Plugs for Obsolete DE Busway

A variety of fusible and circuit breaker plugs are available for


Type DE busway. Nonfusible operating switch plugs are available.
(Not UL Listed) Order by description. For Class R or Class J
provisions, see page 13-93.

Circuit BreakersStandard Frames Three-Phase, Circuit BreakersStandard Frames Three-Phase,


Three-Wire TEB Four-Wire TEB
Voltage Trip Amps Product Number Voltage Trip Amps Product Number
240 V Fixed Trip 15 DE31EB 240 V Fixed Trip 15 DE41EB
240 V Fixed Trip 20 DE32EB 240 V Fixed Trip 20 DE42EB
240 V Fixed Trip 30 DE33EB 240 V Fixed Trip 30 DE43EB
240 V Fixed Trip 40 DE34EB 240 V Fixed Trip 40 DE44EB
240 V Fixed Trip 50 DE35EB 240 V Fixed Trip 50 DE45EB
240 V Fixed Trip 70 DE37EB 240 V Fixed Trip 70 DE47EB
240 V Fixed Trip 100 DE310EB 240 V Fixed Trip 100 DE410EB

Circuit BreakersStandard Frames Three-Phase, Circuit BreakersStandard Frames Three-Phase,


Three-Wire TED4 Four-Wire TED4
Voltage Trip Amps Product Number Voltage Trip Amps Product Number
480 V Fixed Trip 15 DE31ED4 480 V Fixed Trip 15 DE41ED4
480 V Fixed Trip 20 DE32ED4 480 V Fixed Trip 20 DE42ED4
480 V Fixed Trip 30 DE33ED4 480 V Fixed Trip 30 DE43ED4
480 V Fixed Trip 40 DE34ED4 480 V Fixed Trip 40 DE44ED4
480 V Fixed Trip 50 DE35ED4 480 V Fixed Trip 50 DE45ED4
480 V Fixed Trip 70 DE37ED4 480 V Fixed Trip 70 DE47ED4
480 V Fixed Trip 100 DE310ED4 480 V Fixed Trip 100 DE410ED4

Circuit BreakersStandard Frames Three-Phase, Circuit BreakersStandard Frames Three-Phase,


Three-Wire TED6 Four-Wire TED6
Voltage Trip Amps Product Number Voltage Trip Amps Product Number
600 V Fixed Trip 15 DE31ED6 600 V Fixed Trip 15 DE41ED6
600 V Fixed Trip 20 DE32ED6 600 V Fixed Trip 20 DE42ED6
600 V Fixed Trip 30 DE33ED6 600 V Fixed Trip 30 DE43ED6
600 V Fixed Trip 40 DE34ED6 600 V Fixed Trip 40 DE44ED6
600 V Fixed Trip 50 DE35ED6 600 V Fixed Trip 50 DE45ED6
600 V Fixed Trip 70 DE37ED6 600 V Fixed Trip 70 DE47ED6
600 V Fixed Trip 100 DE310ED6 600 V Fixed Trip 100 DE410ED6

Circuit BreakersStandard Frames Three-Phase, Circuit BreakersStandard Frames Three-Phase,


Three-Wire TFK Four-Wire TFK
Voltage Trip Amps Product Number Voltage Trip Amps Product Number
600 V Fixed Trip 70 DE37FK 600 V Fixed Trip 70 DE47FK
600 V Fixed Trip 100 DE310FK 600 V Fixed Trip 100 DE410FK
600 V Fixed Trip 125 DE312FK 600 V Fixed Trip 125 DE412FK
600 V Fixed Trip 150 DE315FK 600 V Fixed Trip 150 DE415FK
600 V Fixed Trip 200 DE320FK 600 V Fixed Trip 200 DE420FK
600 V Fixed Trip 225 DE322FK 600 V Fixed Trip 225 DE422FK

Circuit BreakersStandard Frames Three-Phase, Circuit BreakersStandard Frames Three-Phase,


Three-Wire TJK4 Four-Wire TJK4
Voltage Trip Amps Product Number Voltage Trip Amps Product Number
600 V Inter. Trip 125 DFPJK1312DE 600 V Inter. Trip 125 DFPJK1412DE
600 V Inter. Trip 150 DFPJK1315DE 600 V Inter. Trip 150 DFPJK1415DE
600 V Inter. Trip 200 DFPJK1320DE 600 V Inter. Trip 200 DFPJK1420DE
600 V Inter. Trip 225 DFPJK1322DE 600 V Inter. Trip 225 DFPJK1422DE
600 V Inter. Trip 300 DFPJK1330DE 600 V Inter. Trip 300 DFPJK1430DE
600 V Inter. Trip 400 DFPJK1340DE 600 V Inter. Trip 400 DFPJK1440DE

Rev. 11/13 www.geindustrial.com BuyLog Catalog 13-95


Data subject to change
without notice
Busway Section 13
Type DE Busway
Distribution Equipment
Busway Plugs for Obsolete DE Busway

FusibleOperating Switch Type Three-Phase, Three-Wire Circuit BreakersHi-Break Frames Three-Phase,


Amperage Voltage Product Number Three-Wire THJK4
30 240 DE321R Amperage Voltage Product Number
60 240 DE322R
600 V Inter. Trip 125 DFPHJK312DE
100 240 DE323R
600 V Inter. Trip 150 DFPHJK315DE
200 240 DE324R
600 V Inter. Trip 200 DFPHJK320DE
400 240 DE325RT
600 V Inter. Trip 225 DFPHJK322DE
600 240 DE326R
600 V Inter. Trip 300 DFPHJK330DE
30 600 DE361R
600 V Inter. Trip 400 DFPHJK340DE
60 600 DE362R
100 600 DE363R
200 600 DE364R
400 600 DE365R Circuit BreakersHi-Break Frames Three-Phase,
600 600 DE366R
Four-Wire THED
With QMR Interrupter (with Class H fuse clipsfuses not included)
Amperage Voltage Product Number
600 V Fixed Trip 15 DE41HED
600 V Fixed Trip 20 DE42HED
FusibleOperating Switch Type Three-Phase, Four-Wire 600 V Fixed Trip 30 DE43HED
Amperage Voltage Product Number 600 V Fixed Trip 40 DE44HED
600 V Fixed Trip 50 DE45HED
30 240 DE421R
600 V Fixed Trip 70 DE47HED
60 240 DE422R
600 V Fixed Trip 100 DE410HED
100 240 DE423R
200 240 DE424R
400 240 DE425RT
600 240 DE426R Circuit BreakersHi-Break Frames Three-Phase,
30 600 DE461R
60 600 DE462R Four-Wire THFK
100 600 DE463R Amperage Voltage Product Number
200 600 DE464R
600 V Inter. Trip 70 DE47HFK
400 600 DE465RT
600 V Inter. Trip 100 DE410HFK
600 600 DE466R
600 V Inter. Trip 125 DE412HFK
With QMR Interrupter (with Class H fuse clipsfuses not included) 600 V Inter. Trip 150 DE415HFK
600 V Inter. Trip 200 DE420HFK
600 V Inter. Trip 225 DE422HFK

Circuit BreakersHi-Break Frames Three-Phase,


Three-Wire THED Circuit BreakersHi-Break Frames Three-Phase,
Amperage Voltage Product Number
Four-Wire THJK4
600 V Fixed Trip 15 DE31HED
Amperage Voltage Product Number
600 V Fixed Trip 20 DE32HED
600 V Fixed Trip 30 DE33HED 600 V Inter. Trip 125 DFPHJK412DE
600 V Fixed Trip 40 DE34HED 600 V Inter. Trip 150 DFPHJK415DE
600 V Fixed Trip 50 DE35HED 600 V Inter. Trip 200 DFPHJK420DE
600 V Fixed Trip 70 DE37HED 600 V Inter. Trip 225 DFPHJK422DE
600 V Fixed Trip 100 DE310HED 600 V Inter. Trip 300 DFPHJK430DE
600 V Inter. Trip 400 DFPHJK440DE

Circuit BreakersHi-Break Frames Three-Phase,


Ground Detector Plugs Three-Phase, Three-Wire
Three-Wire THFK
Amperage Voltage Product Number
Amperage Voltage Product Number
GN 208-240 DEGN32R
600 V Inter. Trip 70 DE37HFK
GN 440-600 DEGN36R
600 V Inter. Trip 100 DE310HFK
600 V Inter. Trip 125 DE312HFK (Not UL Listed)
600 V Inter. Trip 150 DE315HFK
600 V Inter. Trip 200 DE320HFK
600 V Inter. Trip 225 DE322HFK

13-96 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Automatic Transfer Switches Section 14

Automatic Transfer Switches ...................................................14-2


ATS (Residential) / ZTX Series ..............................................................14-4
ATS (Commercial) / ZTG Series ...........................................................14-6
ATS (Specification) / ZTS Series........................................................14-15
ATS (Specification) / ZTE Series........................................................14-32
ATS (Specification) / ZTED Series ....................................................14-34
ATS (Specification) / ZTECT Series ..................................................14-36
ATS (Specification) / ZBTE Series.....................................................14-38
ATS (Specification) / ZBTED Series..................................................14-40
ATS (Specification) / ZBTECT Series................................................14-42

Rev. 11/13 www.geindustrial.com BuyLog Catalog 14-1


Data subject to change
without notice
Automatic Transfer Switches Section 14
Critical Power Products
Introduction

Automatic Transfer Switches


It is imperative that emergency power systems allow for a smooth
transition from a normal source to an emergency source and back
again. Our automatic transfer switches are field-proven to be
superior in design and reliability, regardless of the application.
Model ZTX is built specifically for residential and light commercial
applications. The switches are ideal for standby applications, and
are available as NEMA 1 or NEMA 3R enclosed.
Model ZTG is a product solution designed for standard open
transition applications. Building on ZTS technology, the series uses
the MX150 microprocessor control system and includes many of
the most common features specified on a transfer switch. It also
provides an intuitive user interface, communications capability
and self-diagnostics.
Model ZTGD has the features of the ZTG Series but is built for de-
layed transition applications that require the dependability and
ease of operation of a power contactor switch.
Model ZTGSE has the features of the ZTG Series but is built for a
service entrance application that integrates the utility circuit
breaker, optional surge protection device and power monitor into
one simple coordinated package.
Model ZTGDSE has the features of the ZTG Series but is built for
delayed transition service entrance application that integrates the
utility circuit breaker, optional surge protection device and power Model ZTSMV Medium Voltage Automatic Transfer Switches are
monitor into one simple coordinated package. designed for installations from 5 kV to 15 kV and loads up to 3000
amps.
Model ZTS is the building block of the transfer switch product line.
Available in open type or NEMA enclosed to customer specifica- Model ZTE is specifically designed for large healthcare and
tions, the ZTS withstand and closing ratings far exceed UL require- mission-critical applications, with built-in metering,
ments and comes standard with our MX250 controller. communications and advanced diagnostics.
Model ZTSD of delayed transition transfer switches allows for the ZTE Automatic Transfer Switches go beyond simply source
full decay of rotating motors or transformer fields. They can also switching and are available from 40-4000A and 120-600V.
be used for load shedding of selected circuits or other applications. ZTE Series, Standard (Open) Transition. The GE Zenith ZTE stan-
Model ZBTS Bypass-Isolation Transfer Switches are the solution dard (open) transition transfer switches go beyond just source
when power interruption during service or testing is unaccept- switching. Integral metering and communications, high-level
able. Incorporating a quick-make/quick-break manual load trans- diagnostics and superlative flexibility make the ZTE a perfect
fer handle and GE Zenith Controls control/interlock system, the solution for todays mission critical source switching.
bypass uses normal failure sensing and a time delay to start the ZTED Series, Delayed Transition. The ZTED - Delayed Transition
engine automatically if a failure occurs when the automatic trans- transfer switch offers the same features as the ZTE with the
fer switch (ATS) has been removed for service. addition of an adjustable time delay in the centered "off" position.
Model ZBTSD Delayed Transition Transfer/Bypass-Isolation This delay allows motor loads to coast down and transformer field
Switches incorporate the features of the ZBTS Bypass-Isolation to decay; ensuring inductive loads are re-energized after transfer
Switch and the ZTSD unit for transfer of large motor loads, with only normal inrush starting currents.
transformers, uninterruptible power supplies (UPS) systems or ZTECT Series, Closed Transition. The ZTECT -Closed Transition
load shedding to a neutral off position. transfer switch offers the same features as the ZTE with the
Model ZTSCT of closed transition switches combine ZTSD addition of a high-speed drive system, which ensures the overlap
operation during a source failure with a highly engineered of the normal and alternate sources is less than 100 milliseconds.
control system that allows momentary paralleling of two When one source is not within normal limits, such as during a
acceptable sources, limiting the impact of transfer on the load. power outage, the ZTECT automatically operates in delayed
transition mode.
Model ZBTSCT Closed Transition Transfer/Bypass-Isolation
Switches combines all the functionality of our bypass and closed
transition switches for the highest level in reliability.

14-2 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Automatic Transfer Switches Section 14
Critical Power Products
Introduction

ZBTE Series Bypass-Isolation Transfer Switches are the


solution when interruption of power during service or test-
ing is not acceptable. Consisting of two major modules
the Automatic Transfer (ATS) and the Bypass/Isolation
Switchthe ZBTE Series like the ZTE Series, incorporates
the most advanced moicroprocessor controller in the
industry as well as the same advanced rugged construc-
tion of all our ZTE Series automatic switches with a quick
make/quick break bypass switch manual load transfer
handle and our control/interlock system, which consists of
both mechanical and electrical interlocks.
ZBTE - Standard (Open) Transition Bypass/Isolation.
The Zenith ZBTE Bypass/Isolation transfer switch is used
in general and mixed load applications
ZBTSE - Delayed Transition Bypass/Isolation. The ZBTED
Bypass/Isolation transfer switch is used to transfer large
motor loads, transformers, uninterruptible power
supplies (UPS) systems or load shedding to a neutral
"center" position.
ZBTECT - Closed Transition Bypass/Isolation. The ZBTECT
Bypass/Isolation transfer switch is used to transfer critical
loads where a "no break" transfer is desired.

Rev. 11/13 www.geindustrial.com BuyLog Catalog 14-3


Data subject to change
without notice
Automatic Transfer Switches Section 14
Critical Power Products
Model ZTX

Features
Model ZTX switches are built for residential and light commercial
applications requiring the dependability and ease of operation
found in a power contactor switch.

Ratings 40 to 400 amps (2, 3 and 4 pole)


UL 1008, CSA and IEC listed to 480 VAC 50/60Hz
Double throw, mechanically interlocked contactor mechanism
Electrically operated, mechanically held
Designed for standby applications
Equipment (controls & power section) seismic test qualified to:
IBC-2009
IEEE-693-2005

Model ZTX switches are equipped with the MX60 control panel as
standard. This microprocessor control includes:

Undervoltage sensing (90% pickup/80% dropout) of the


utility source
Voltage and frequency sensing of the generator source
(90% voltage/95% frequency pickup)
Time Delay Engine Start 5 seconds (P)
Time Delay Engine Warmup Transfer to Generator
20 seconds (W)
Time Delay Utility Stabilization/Retransfer to Utility 5 minutes (T)
Time Delay Engine Cool Down 5 minutes (U)
All time delays are fixed. ZTX Series Residential and Light Commercial Switch
Indicating LEDs for source availability and switch position with MX60 Control Panel (front cover removed)
Pushbuttons for test, engine start (manual), generator exer-
ciser and diagnostic reset
Special status annunciation of in-phase transfer and timer
operation
Selectable 7, 14, 21 or 28 day (factory set 28 days) generator
exerciser timer
Diagnostic LED indications

Additional options include:


A3/A4 Auxiliary contacts (1 each) closed in utility and generator
positions
B9X 1.5 Amp/12 or 24 VDC Battery Charger
MX60 Microprocessor Control Panel

14-4 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Automatic Transfer Switches Section 14
Critical Power Products
Model ZTX

Ordering Information

Z T X 0 0 0 0 Z E C Z V C M 0 6 0
Model/Type Control Application Ampere Switched Enclosure Type Operational Voltage Accessories
Panel Size Poles

Z T X 0 0 0 M 6 0 0 0 4 B 0 1 A B A3/A4
Standard (Open Transition) MX60 Micro- Utility- 40 amps 2 Poles Type 1 Enclosed Consult Table Below Auxiliary Contacts (1 each)
processor Generator Closed in Source 1 (normal)
Control Unit and Source 2 (emergency)

0 0 8 E 3 R
0 0 80 amps 3 Poles Type 3R Enclosure
B9X
No Microprocessor Battery Charger
Control Unit 1.5 Amp/12 or 24 VDC
0 1 0 F 0 0
100 amps 4 Poles Open Style For information on
Unit
ZTX OEM plans,
0 1 5 please consult your
GE representative
150 amps

0 2 0 0 2 2 A B Voltage Phase Config. Hz

200 amps 225 amps 1 0 120 1 2 wire 60


2 0 120/240 1 3 wire 60
2 1 120/208 1 3 wire 60
0 3 0 0 4 0 3 0 240 3 3 wire 60
3 1 208 3 3 wire 60
300 amps 400 amps
3 2 220 3 3 wire 50
3 3 120/240 3 4 wire 50
3 4 110/220 3 4 wire 60
Product # Example 3 5 139/240 3 4 wire 60
3 8 120/240 3 4 wire 60
ZTX000M60010E-ZEC01ZVC50M060 4 0 120/208 3 4 wire 60
This number string shows the correct format for a ZTX 4 1 127/220 3 4 wire 60
4 2 127/220 3 4 wire 50
Model Automatic Transfer Switch with MX60 micro- 5 0 480 3 3 wire 60
processor control unit, Utility-Generator, 100 amps, 3 5 1 440 3 3 wire 60
5 2 440 3 3 wire 50
pole, NEMA Type 1 enclosure, 480 V, 3, 3 wire, 60 Hz 5 5 460 1 3 wire 50
system with the standard group of accessories. 5 7 480 1 2 wire 60
5 8 254/440 3 4 wire 60
7 0 277/480 3 4 wire 60
Technical Specifications 7 1 277 1 2 wire 60
7 4 266/460 3 4 wire 60
Lug Configuration 7 5 460 3 3 wire 60
Qty Per Phase 8 2 380 1 2 wire 50
Amp Size and Neutral Size 9 0 240/416 3 4 wire 60
40-80 1 #8 to 3/0 8 to 85 mm2 9 1 220/380 3 4 wire 60
9 2 220/380 3 4 wire 50
100-225 1 #6 to 250 MCM 13 to 127 mm2
9 3 240/416 3 4 wire 50
300-400 1 #4 to 600 MCM 21 to 304 mm2 9 7 380 3 3 wire 60

Note: Operating voltage must be specified at time of order.


Only the most common voltages are shown above.

Dimensions
Ampere NEMA 1 NEMA 3R
Poles
Rating Height Width Depth Height Width Depth
40-225 2, 3, 4 24 18 10 24 18.5 10.5
300-400 2, 3, 4 46 24 14 46 24 15

UL 1008 Withstand and Closing Ratings


Please refer to GE Zenith Controls Bulletin TB-1102.

Rev. 11/13 www.geindustrial.com BuyLog Catalog 14-5


Data subject to change
without notice
Automatic Transfer Switches Section 14
Critical Power Products
Models ZTG and ZTGD

Features
Model ZTG switches are built for standard applications requiring
the dependability and ease of operation found in a power
contactor switch.

Ratings 40 to 3000 amps (2, 3 or 4 poles)


UL 1008 listed at 480 VAC
CSA certified at 600 VAC (200-260 amp-480V)
IEC listed at 480V
Equipment (controls and power section) seismic test qualified to:
IBC2009
IEEE6932005
Double throw, mechanically interlocked contactor mechanism
Electrically operated, mechanically held
Designed for emergency and standby applications
Available in standard (ZTG) or delayed transition (ZTGD) models

ZTG switches are equipped with GE Zeniths next-generation


MX150 microprocessor panel, which controls the operation and
displays the status of the transfer switchs position, timers and
available sources. As an embedded digital controller, the MX150
offers high reliability and ease of unattended operation across a
range of applications. The MX150 features include:

Timer and voltage/frequency settings adjustable without


disconnection from the power section Design and Construction Features
Built-in diagnostics with LCD displays for immediate Close differential 3 phase under-voltage sensing of the normal
troubleshooting sourcefactory standard setting 90% pickup, 80% dropout (ad-
LED/LCD indicators for ease of viewing and long life justable); under-frequency sensing of the normal source factory
Nonvolatile memoryclock battery backup not required for setting 95% pickup (adjustable)
standard switch operation Voltage and frequency sensing of the emergency source
Processor and digital circuitry isolated from line voltage factory standard setting 90% pickup voltage, 95% pickup
Inputs optoisolated for high electrical immunity to transients frequency (adjustable)
and noise Test switch (fast test/load/no load) to simulate normal source fail-
Communications header for network interface ureautomatically bypassed should the emergency source fail
Type 1 enclosure is standardalso available in open style or
Types 3R, 4, 4X or 12
Fully Approved
UL, CSA and IEC listed
IBC2009
IEEE6932005
Ringing wave immunity per IEEE 472 (ANSI C37.90A)
Conducted and Radiated Emissions per EN55022 Class B
(CISPR 22) (Exceeds EN55011 and MILSTD 461 Class 3)
ESD immunity test per EN61000-4-2 Class B (Level 4)
Radiated RF, electromagnetic field immunity test per EN61000-
4-3 (ENV50140) 10v/m
Electrical fast transient/burst immunity test per EN61000-4-4
Surge immunity test per EN61000-4-5 IEEE C62.41 (1.2 X 50s,
0.5 and 4 kV)
Conducted immunity test per EN61000-4-6 (ENV50141)
Voltage dips and interruption immunity EN61000-4-11

14-6 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Automatic Transfer Switches Section 14
Critical Power Products
Models ZTG and ZTGD

Options
6A Test Switch, Maintained UMD Universal Motor Load Disconnect Circuit: Auxiliary Con-
6AP Test Switch, Maintained Programmable tact opens 0-5 minutes prior to transfer in either direc-
A1 Auxiliary Contact, operates on Source 1 line failure tion, re-closes after transfer. Can be configured by end
A1E Auxiliary Contact, operates on Source 2 line failure user for Pre-transfer, Post-transfer, or both.
A3 Auxiliary Contacts: Closed when the transfer switch is in VI Voltage Imbalance Monitor (Three Phase)
Source 2 position NOTE: For applications requiring additional options or other configurations, use
A4 Auxiliary Contacts: Closed when the transfer switch is in GE Zenith Factory.
Source 1 position
A62 Sequential Universal Motor Load Disconnect Circuit.
Normally closed Auxiliary contacts for Motor Loads.
Open 0-60 seconds pior to transfer, after transfer, or
both in either direction then reclose in timed sequence
after transfer.
ATGEW-X Extended annual parts and labor warranty (1-4 years for
a total of 5 years max.)
CTAP Alarm panel on transfer to emergency w/silence button
& light
DS Inhibits transfer in either direction when in inhibit. Allows
automatic operation when in Auto (Standard on 800A
and above)
HT Heater and Thermostat
LCM LonWorks Communication Module
MCM Modbus RTU Communication Module

M90 Series Power Measurement Meters


(Not available in NEMA 4 enclosure)
M90 EPM2000 True RMS Digital Meter with display (Amps,
Volts, Power, Energy, Power Factory and Frequency). 3
Line LED Display. 50/60 Hz Universal Operation. 1 or 3
phase. Standard Modbus RTU RS485 communications
capability. 40 1200 Amps.
M90A Adds Pre-Wiring for Enervista Viewpoint Monitoring of
M90 Accessory & ATS Status using Modbus RS485 Serial
Communications
M90B Adds Pre-Wiring for Enervista Viewpoint Monitoring of
M90 Accessory & ATS Status using Ethernet TCP/IP
Communications
M91 EPM6000 True RMS Digital Meter with display (Amps,
Volts, Power, Energy, Power Factory and Frequency,
THD). Certified energy and demand metering. Meets
ANSI C12.20 and IEC 687 Accuracy Classes. Front IrDA
Port Laptop Connection. Standard Modbus RTU RS485 or
DNP 3.0 communications capability.
M91A Adds Pre-Wiring for Enervista Viewpoint Monitoring of
M91 Accessory & ATS Status using Modbus RS485 Serial
Communications
M91B Adds Pre-Wiring for Enervista Viewpoint Monitoring of
M91 Accessory & ATS Status using Ethernet TCP/IP
Communications
OCVR-1SG Lockable see-through microprocessor cover for NEMA
3R or 12
OCVR-1SS Lockable see-through microprocessor and meters cover
for NEMA 3R or 12
T3/W3 Elevator Pre-Signal Auxiliary Contacts: Open 0-60
seconds prior to transfer to either direction, re-closes
after transfer.

Rev. 11/13 www.geindustrial.com BuyLog Catalog 14-7


Data subject to change
without notice
Automatic Transfer Switches Section 14
Critical Power Products
Model ZTG
Reference Charts

Testing Standards
UL, CSA and IEC listed UL 1008, CSA 22.2 No. 178, IEC 947-6-1
Ringing wave immunity IEEE 472 (ANSI C37.90A)
Conducted and Radiated Emissions EN55022 Class B (CISPR 22) (Exceeds EN55011 & MILSTD 461 Class 3)
ESD immunity test EN61000-4-2 Class B (Level 4)
Radiated RF, electromagnetic field immunity test EN61000-4-3 (ENV50140) 10v/m
Electrical fast, transient/burst immunity test EN61000-4-4
Surge immunity test EN61000-4-5 IEEE C62.41 1.2 X 50s, 0.5 & 4 kV
Conducted immunity test EN61000-4-6 (ENV50141)
Voltage dips and interruption immunity EN61000-4-11

ZTG AL/CU UL Listed Solderless Screw-Type Terminals for External Power Connections1
Normal, Emergency and Load Terminals
Switch Size (Amps) Cables per Phase & Neutral Range of Wire Sizes
40
1 #8 to 3/0 8-85 mm2
80
100
150 1 #6 to 250 MCM 13-127 mm2
200, 225
260 #6 to 350 MCM 13-177 mm2
1
400 #4 to 600 MCM 21-304 mm2
600 2
#2 to 600 MCM 33-304 mm2
800, 1000, 1200 4
1600, 2000, 2600, 3000 8 #2 to 600 MCM 33-304 mm2
1 For ZTGD Series data, contact the GE Zenith factory

Standard MX150 Control Setting Ranges


Control Function Range Factory Setting
75-98% 80%
Source 1 Line Sensing Under-voltage Dropout/Pickup
85-100% 90%
75-98% 80%
Source 2 Line Sensing Under-voltage Dropout/Pickup
85-100% 90%
88-98% 90%
Source 2 Line Sensing Under-frequency Dropout/Pickup
90-100% 95%
MSTDG Time Delay Engine Start (Acc. P1) 0-10 seconds 3 seconds
Time Delay Engine Cool Down (Acc. U) 0-60 minutes 5 minutes
Time Delay Transfer to Source 2 (Acc. W) 0-5 minutes 1 second
Time Delay Retransfer to Source 1 (Acc. T) 0-60 minutes 30 minutes
Time Delay Motor Disconnect or Transfer Presignal (Acc. UMD, or T3/W3) 0-60 seconds 20 seconds
Delayed Transition Time Delays (DT, DW) 0-10 minutes 5 seconds
Event Exerciser (CDT) 5-60 min.-1,7,14 or 28 days load or no load 20 min. - 7 days no load
Programmable Event Exerciser (CDP) 365 day cycle, load or no load 0 min. - 7 days no load
MEXEG Voltage Imbalance (VI) 5-20% nominal; 10-30 sec. 10% Fail, 8% Restore; 30 sec.
Elevator Pre-Signal (T3/W3) 0-60 seconds 20 seconds
Options Sequential Motor Load Disconnect (A62) 0-5 minutes 20 seconds
Motor Load Disconnect (UMD) 0-60 seconds 5 seconds

14-8 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Automatic Transfer Switches Section 14
Critical Power Products
ZTG Series

Ordering Information
Z A 0 Z E C Z V C
Model/Type Control Application Ampere Switched Enclosure Type Operational Voltage Accessories
Panel Size Poles

Z T G 0 0 0 A 0 0 0 0 4 B 0 1 A B M S T D
Standard (Open Transition) Entelli-Switch Utility- 40 amps 2 Poles Type 1 Enclosed Consult Table Below
150 Micro- Generator M E X E
processor
Control Unit
U 0 0 8 E 1 2
Z T G D 0 0 Utility- 80 amps 3 Poles Type 12 Enclosure M A N O
Utility Then choose
Delayed Transition
M 0 1 0 F 3 R additional accessories

Manual 100 amps 4 Poles Type 3R Enclosure 6A


Transfer
0 1 5 4 0 6AP
150 amps Type 4 Enclosure
A1
0 2 0 4 X A1E
Switch Types
200 amps Type 4X Enclosure
Standard: Unless otherwise noted, the A3
standard switch with quick transfer will 0 2 2
be supplied.
0 0 A4
225 amps Open Style Unit
Delayed Transition: When ordered as
the ZTGD, the delayed transition switch A62
offers time delay during transfer from 0 2 6 A B Voltage Phase Config. Hz
260 amps
ATGEW-X
one position to the other. This is primarily 1 0 120 1 2 wire 60
2 0 120/240 1 3 wire 60
for transfer of large motor or inductive 2 1 120/208 1 3 wire 60 CTAP
loads. The operation of the delayed 0 4 0 3 0 240 3 3 wire 60
transition switch is totally independent 400 amps 3 1 208 3 3 wire 60 DS
3 2 220 3 3 wire 50
of the synchronism of the power sources, 3 3 120/240 3 4 wire 50
eliminating the need for in-phase monitors 0 6 0 3 4 110/220 3 4 wire 60 HT
or extensive motor-disconnect control 3 5 139/240 3 4 wire 60

wiring between the transfer switch and


600 amps 3 8 120/240 3 4 wire 60 LCM
4 0 120/208 3 4 wire 60
motor control centers. 0 8 0 4 1 127/220 3 4 wire 60
M90
4 2 127/220 3 4 wire 50
800 amps 5 0 480 3 3 wire 60
5 1 440 3 3 wire 60 M90A
5 2 440 3 3 wire 50
1 0 0 5 5 460 1 3 wire 50
M90B
5 7 480 1 2 wire 60
Product # Example 1000 amps 5 8 254/440 3 4 wire 60
ZTG000A00040F-ZEC01ZVC40MSTD 6 0 575 3 3 wire 60 M91
6 1 347/600 3 4 wire 60
This number string shows the correct format 1 2 0
for a ZTG Series Automatic Transfer Switch
7 0 277/480 3 4 wire 60 M91A
1200 amps 7 1 277 1 2 wire 60
with an MX150 microprocessor control unit, 7 4 266/460 3 4 wire 60
7 5 460 3 3 wire 60 M91B
Utility - Generator, 400 amps, 4 pole, NEMA 1 6 0 8 0 120/240 2 4/5 wire 60
Type 1 enclosure, 120/208V 3, 4 wire, 60 Hz 8 2 380 1 2 wire 50 MCM
1600 amps 9 0 240/416 3 4 wire 60
system with the standard group of accessories.
9 1 220/380 3 4 wire 60
9 2 220/380 3 4 wire 50 OCVR-15G
2 0 0 9 3 240/416 3 4 wire 50
2000 amps 9 7 380 3 3 wire 60 OCVR-1SS
UL 1008 Withstand and Closing Ratings Note: Operating voltage must be specified at time of order.
Please refer to GE Zenith Controls Bulletin 2 6 0 Only the most common voltages are shown above. T3/W3
TB-1102. 2600 amps UMD
3 0 0 VI
3000 amps
None

Rev. 11/13 www.geindustrial.com BuyLog Catalog 14-9


Data subject to change
without notice
Automatic Transfer Switches Section 14
Critical Power Products
Models ZTG and ZTGD

Dimensional and Weight Specifications


NEMA 1 Weight
Ampere Ref. Open NEMA Application
Model Rating Poles Height (A) Width (B) Depth (C) Figure Type 1 Notes
2, 3 24 (61) 18 (46) 11 (28) A 21 (10) 57 (26)
40, 80 1-6
4 24 (61) 18 (46) 11 (28) A 21 (10) 60 (27)
2, 3 24 (61) 18 (46) 11 (28) A 21 (10) 57 (26)
100, 150 1-6
4 24 (61) 18 (46) 11 (28) A 21 (10) 60 (27)
2, 3 24 (61) 18 (46) 11 (28) A 21 (10) 57 (26)
200 1-6
4 24 (61) 18 (46) 11 (28) A 21 (10) 60 (27)
2, 3 46 (117) 24 (61) 14 (36) A 70 (32) 175 (80)
ZTG 225, 260, 400 1-5
4 46 (117) 24 (61) 14 (36) A 75 (34) 180 (82)
2, 3 66 (168) 24 (61) 19.5 (50) B 165 (75) 400 (450)
600 1 - 5, 7
4 66 (168) 24 (61) 19.5 (50) B 185 (84) 450 (204)
2, 3 74 (188) 40 (102) 19.5 (50) B 190 (86) 455 (206)
800, 1000, 1200 1 - 5, 7
4 74 (188) 40 (102) 19.5 (50) B 210 (95) 540 (245)
3 90 (229) 35.5 (90) 48 (122) C 345 (156) 1010 (458)
1600, 2000 1 - 5, 7-8
4 90 (229) 35.5 (90) 48 (122) C 450 (204) 1160 (526)
3 90 (229) 35.5 (90) 48 (122) C 465 (211) 1010 (458)
2600, 3000 1 - 5, 7-8
4 90 (229) 35.5 (90) 48 (122) C 670 (304) 1160 (526)
2, 3 46 (117) 24 (61) 14 (36) A 21 (10) 57 (26)
40, 80 1-6
4 46 (117) 24 (61) 14 (36) A 21 (10) 60 (27)
2, 3 46 (117) 24 (61) 14 (36) A 21 (10) 57 (26)
100, 150 1-6
4 46 (117) 24 (61) 14 (36) A 21 (10) 60 (27)
2, 3 46 (117) 24 (61) 14 (36) A 21 (10) 57 (26)
200, 225 1-6
4 46 (117) 24 (61) 14 (36) A 21 (10) 60 (27)
2, 3 46 (117) 24 (61) 14 (36) A 80 (36) 220 (100)
260, 400 1-5
ZTGD 4 46 (117) 24 (61) 14 (36) A 85 (39) 230 (102)
2, 3 66 (168) 24 (61) 19.5 (50) B 185 (84) 400 (181)
600 1 - 5, 7
4 66 (168) 24 (61) 19.5 (50) B 205 (93) 450 (204)
2, 3 74 (188) 40 (102) 19.5 (50) B 210 (95) 475 (215)
800, 1000, 1200 1 - 5, 7
4 74 (188) 40 (102) 19.5 (50) B 230 (104) 560 (254)
3 90 (229) 35.5 (90) 48 (122) C 365 (166) 1010 (458)
1600, 2000 1 - 5, 7-8
4 90 (229) 35.5 (90) 48 (122) C 470 (204) 1160 (526)
3 90 (229) 35.5 (90) 48 (122) C 485 (220) 1130 (513)
2600, 3000 1 - 5, 7-8
4 90 (229) 35.5 (90) 48 (122) C 690 (313) 1395 (633)

Application Notes:
1. Metric dimensions (cm) and weights (kg) shown in parentheses adjacent to English measurements.
2. Includes 1.25" door projection beyond base depth. Allow a minimum of 3" additional depth for projection of handle, lights, switches, pushbuttons, etc.
3. All dimensions and weights are approximate and subject to change without notice.
4. Packing materials must be added to weights shown. Allow 15% additional weight for cartons, skids, crates, etc.
5. Special enclosure (NEMA 3R, 4, 4X, 12, etc.) dimensions and layouts may differ. Consult the GE Zenith factory for details.
6. A ZTG(D) 40-225A, when ordered with the following options, will require a larger enclosure: A62(T), Digital Meter, HT, OCVR-1SG, OCVR-1SS.
Contact the GE Zenith factory for dimensions.
7. Add 3" in height for removable lifting eyes.
8. Ventilation louvers on side and rear of enclosure at 1600-3000 amps. One set of louvers must be clear for airflow with standard cable connections.

Reference Figures

Figure A Figure B Figure C

14-10 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Automatic Transfer Switches Section 14
Critical Power Products
Models ZTGSE and ZTGDSE

Features
While providing the functionality of an automatic transfer switch
the ZTGSE integrates the utility circuit breaker, optional surge
protection device and power monitor into one simple
coordinated package.

Suitable for use as Service Entrance equipment


Ratings 40 to 3000 amps (2, 3 or 4 poles)
UL 1008 listed at 480 Vac
Double throw, mechanically interlocked
contactor mechanism
Electrically operated, mechanically held
Designed for emergency and standby applications
Optional Load center for multiple loadside connections
available up to 240 volts
Additional options include battery charger, GFP, shunt trip
selector, power monitor and surge protection device
Available with delayed transition feature

ZTGSE switches are equipped with GE Zeniths next-generation


MX150 microprocessor panel, which controls the operation and
displays the status of the transfer switchs position, timers and
available sources. As an embedded digital controller, the MX150
offers high reliability and ease of unattended operation across a Design and Construction Features
range of applications. The MX150 features include: Includes Normal (Source 1) molded or insulated case style
circuit breaker 2 or 3 pole
Timer and voltage/frequency settings adjustable without
Includes mechanical lug connections for cables
disconnection from the power section
Close differential 3 phase under-voltage sensing of the normal
Built-in diagnostics with an LCD display for immediate
sourcefactory standard setting 90% pickup, 80% dropout (ad-
troubleshooting
justable); under-frequency sensing of the normal source
LED/LCD indicators for ease of viewing and long life
factory setting 95% pickup (adjustable)
Nonvolatile memoryclock battery backup not required for
Voltage and frequency sensing of the emergency source
standard switch operation
factory standard setting 90% pickup voltage, 95% pickup
Processor and digital circuitry isolated from line voltage
frequency (adjustable)
Inputs optoisolated for high electrical immunity to transients
Test switch (fast test/load/no load) to simulate normal
and noise
source failureautomatically bypassed should the emergency
Communications header for network interface
source fail
NEMA Type 1 enclosure is standard with optional NEMA 3R
Fully Approved available
Ground fault protection is standard 1000A and above
UL891, UL1008, CSA 22.2
Disconnect link on Neutral and Ground
Ringing wave immunity per IEEE 472 (ANSI C37.90A).
Conducted and Radiated Emissions per EN55022 Class B
(CISPR 11) (Exceeds EN55011 & MILSTD 461 Class 3)
ESD immunity test per EN61000-4-2 (Level 4)
Radiated RF, electromagnetic field immunity test per
EN61000-4-3 (ENV50140) 10v/m
Electrical fast transient/burst immunity test per EN61000-4-4.
Surge immunity test per EN61000-4-5 IEEE C62.41
(1.2 X 50ms, 5 & 8 kV)
Conducted immunity test per EN61000-4-6 (ENV50141)
Voltage dips and interruption immunity EN61000-4-11

Rev. 11/13 www.geindustrial.com BuyLog Catalog 14-11


Data subject to change
without notice
Automatic Transfer Switches Section 14
Critical Power Products
Models ZTGSE and ZTGDSE

Reference Charts
Testing Standards
UL, CSA UL 1008, UL891, CSA 22.2
Ringing wave immunity IEEE 472 (ANSI C37.90A)
Conducted and Radiated Emissions EN55022 Class B (CISPR 11) (Exceeds EN55011 & MILSTD 461 Class 3)
ESD immunity test EN61000-4-2 (Level 4)
Radiated RF, electromagnetic field immunity test EN61000-4-3 (ENV50140) 10v/m
Electrical fast, transient/burst immunity test EN61000-4-4
Surge immunity test EN61000-4-5 IEEE C62.41 1.2 X 50s, 5 & 8 kV
Conducted immunity test EN61000-4-6 (ENV50141)
Voltage dips and interruption immunity EN61000-4-11

AL/CU UL Listed Solderless Screw-Type Terminals for External Power Connections


Normal, Emergency and Load Terminals
Switch Size (Amps) Cables per Pole Range of Wire Sizes
40, 80, 100, 150 #8 to 3/0 AWG 8-85 mm
200, 225 #6 AWG to 250 MCM 13-127 mm
1
260 #6 AWG to 350 MCM 13-177 mm
400 #4 AWG to 600 MCM 21-304 mm
600 2
#2 AWG to 600 MCM 33-304 mm
800 4

14-12 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Automatic Transfer Switches Section 14
Critical Power Products
Models ZTGSE and ZTGDSE

Ordering Information

Z T G S E 0 A 0 0 N 0 1 M S T D G
Base Model Type Control Config. Ampere Size Switched Enclosure Operational Accessories
Panel Poles Type Voltage

S E 0 A 0 0 0 0 4 B N 0 1 A B M S T D G
Standard MX150 Utility - 40 amps 2 Poles Type 1 Enclosure Consult Table
(Open Transition Microprocessor Generator Below M E X E G
Transfer Switch) Control Unit 0 0 8 E N 3 R
80 amps 3 Poles Type 3R Enclosure
D S E If Required, choose
additional accessories.
Standard 0 1 0 F
(Delayed 100 amps 4 Poles
Transition
Transfer Switch)
0 1 5
150 amps

0 2 0 A B Voltage Phase Config. Hz


200 amps 1 0 120 1 2 wire 60
2 0 120/240 1 3 wire 60
0 2 2 2 1 120/208 3 3 wire 60
220 amps 3 0 240 3 3 wire 60
3 1 208 3 3 wire 60
0 2 6 3 2 220 3 3 wire 50
260 amps 3 3 120/240 3 4 wire 50
3 4 110/220 3 4 wire 60
0 4 0 3 5 139/240 3 4 wire 60
Product # Example
400 amps 3 8 120/240 3 4 wire 60
ZTGSE0A0040E-N0140MSTDG 4 0 120/208 3 4 wire 60
This number string shows the correct 0 6 0 4 1 127/220 3 4 wire 60
format for a ZTGSE Series Automatic 600 amps 4 2 127/220 3 4 wire 50
5 0 480 3 3 wire 60
Transfer Switch with an MX150 micro- 0 8 0 5 1 440 3 3 wire 60
processor control unit, Utility - Generator 800 amps 5 2 440 3 3 wire 50
application, 400 amps, 3 pole, NEMA Type 5 5 460 1 3 wire 50
1 enclosure, 120/208V 3, 4 wire, 60 Hz 5 7 480 1 2 wire 60
system with the standard group of 5 8 254/440 3 4 wire 60
6 0 575 3 3 wire 60
accessories. 6 1 347/600 3 4 wire 60
7 0 277/480 3 4 wire 60
7 1 277 1 2 wire 60
7 4 266/460 3 4 wire 60
7 5 460 3 3 wire 60
8 0 120/240 2 4/5 wire 60
8 2 380 1 2 wire 50
9 0 240/416 3 4 wire 60
9 1 220/380 3 4 wire 60
9 2 220/380 3 4 wire 50
9 3 240/416 3 4 wire 50
9 7 380 3 3 wire 60

Note: Will need to specify with order the operating voltage.


Only the most common ones are shown here
Withstand Current Ratings per UL1008
Maximum Circuit Amps
ZTGSE Maximum Circuit Amps When Used With ZTGDSE When Used With
Switch Current Specific Switch Specific
Ratings Limiting Fuse Coordinated Ratings Coordinated
(Amps) ZTGSE/ZTGDSE Breaker Rating (Amps) Breaker Rating
40, 80, 100,
30,000
150, 200, 225 40, 80, 100, 150
50,000
260 200,000 35,000 225, 260, 400, 600
400 - 600 50,000
800 65,000 800 65,000

Rev. 11/13 www.geindustrial.com BuyLog Catalog 14-13


Data subject to change
without notice
Automatic Transfer Switches Section 14
Critical Power Products
Models ZTGSE and ZTGDSE

Dimensional Specifications
ZTGSE and ZTGDSE Model Transfer Switches
NEMA 1 Enclosure NEMA 3R Enclosure
Model Ampere Rating Poles H W D Ref. Fig. H W D Ref. Fig. App. Notes
40-80 2, 3, 4 51(130) 28(71) 16(41) A 51(130) 29(74) 20(51) A 1-5
100-200 2, 3, 4 51(130) 28(71) 16(41) A 51(130) 29(74) 20(51) A 1-5
225 2, 3, 4 51(130) 28(71) 16(41) A 51(130) 29(74) 20(51) A 1-5
ZTGSE/ 260 2, 3, 4 51(130) 28(71) 16(41) A 51(130) 29(74) 20(51) A 1-5
ZTGDSE 400 2, 3, 4 51(130) 28(71) 16(41) A 51(130) 29(74) 20(51) A 1-5
600 2, 3, 4 73(185) 34(86) 20(51) B 73(185) 34(86) 24(61) B 1-6
2, 3 73(185) 34(86) 20(51) B 73(185) 34(86) 24(61) B 1-6
800
4 73(185) 40(102) 20(51) B 73(185) 40(102) 24(61) B 1-6

Application Notes:
1. Metric dimensions (cm) and weights (kg) shown in parentheses adjacent to English measurements.
2. Includes 1.25" door projection beyond base depth. Allow a minimum of 3" additional depth for projection of handle, lights, switches, pushbuttons, etc.
3. All dimensions and weights are approximate and subject to change without notice.
4. Packing materials must be added to weights shown. Allow 15% additional weight for cartons, skids, crates, etc.
5. Add 4 inches in depth for NEMA 3R enclosure.
6. Add 3 in height for lifting eyes.
7. Contact factory for dimensional and weight information for 1000 Amps and above.

Weights
Model Amp Rtg Poles NEMA 1 Weight NEMA 3R Weight
2 157(71) 212(96)
40-80 3 159(72) 214(97)
4 163(74) 218(99)
2 162(74) 217(99)
100-200 3 164(75) 219(99)
4 168(76) 223(101)
2 169(77) 224(102)
225 3 171(78) 226(103)
4 175(79) 230(104)
2 178(81) 233(106)
ZTGSE 260 3 183(83) 238(108)
4 187(85) 242(110)
2 254(115) 309(140)
400 3 265(120) 320(145)
4 289(131) 344(156)
2 467(212) 552(250)
600 3 483(219) 568(257)
4 512(232) 597(271)
2 567(257) 652(296)
800 3 577(262) 662(300)
4 662(300) 767(348)
2 262(119) 317(144)
40-400 3 273(124) 328(149)
4 296(134) 351(159)
2 475(215) 560(254)
ZTGDSE 600 3 491(222) 576(261)
4 520(236) 605(274)
2 570(259) 655(297)
800 3 580(263) 665(302)
4 665(302) 770(349)

Reference Figures

D W
D W

H H

Figure A Figure B
ZTGSE Series Transfer Switch (40-400 Amp) ZTGSE Series Transfer Switch (600-800 Amp)

14-14 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Automatic Transfer Switches Section 14
Critical Power Products
ZTS Series

ZTS Series Automatic Transfer Switches


An Introduction to the ZTS Series of Automatic Transfer Switches

Since its introduction, the GE Zenith ZTS Series of transfer All ZTS products meet or exceed industry requirements allowing
switches has become a hallmark of quality and performance. specification and installation confidence.
Reliability resulting from superior design and heavy duty construction UL 1008 listed through 480 VAC
has made the ZTS the industry standard for critical installations. CSA C22.2 No. 178 listed through 600 VAC
Our emphasis on research and development, design IEC 947-6-1 listed through 480 VAC
improvements, materials, manufacturing methods, quality Codes and Standards
assurance, and service yields products that have been proven in NFPA 70, 99, 101, 110
hundreds of thousands of applications. IEEE 446, 241
NEC 517, 700, 701, 702
Our engineering staff has been dedicated to the improvement and NEMA ICS2-447
expansion of our line. Today, GE Zenith offers the widest selection of Controls tested in accordance with:
transfer switch products worldwide. IEEE 472 (ANSI C37.90A)
ZTS Automatic Transfer Switches EN55022 Class B (CISPR 22) (Exceeds EN55011
40-4000 Amps & MILSTD 461 Class 3)
ZTSD Delayed Transition Transfer Switches EN61000-4-2 (Level 4)
40-4000 Amps EN61000-4-3 (ENV50140) 10 v/m
ZTSCT Closed Transition Transfer Switches EN61000-4-4
100-4000 Amps EN61000-4-5, IEEE C62.41 (1.2 X 50s, 0.5 & 4 kV)
ZBTS Automatic Transfer/Bypass Switches EN61000-4-6 (ENV50141)
100-4000 Amps EN61000-4-11
ZBTSD Delayed Transition Bypass Switches Enclosures meet the requirements of:
100-4000 Amps UL 508, 50
ZBTSCT Closed Transition Bypass Switches ANSI C33.76
100-4000 Amps ICS 6
ZTSMV Medium Voltage Switches NEMA 250
600-3000 Amps Quality System:
ISO 9001 Registered
Equipment (controls and power section) seismic tested to:
IBC2009
IEEE6932003

Rev. 11/13 www.geindustrial.com BuyLog Catalog 14-15


Data subject to change
without notice
Automatic Transfer Switches Section 14
Critical Power Products
Model ZTS
Model ZTS Automatic Transfer Switches
The ZTS Model is the foundation of the transfer switch product
line. This ruggedly built power contactor family of switches has
been specifically designed for transfer switch duty with depend-
ability, versatility and user friendliness of prime concern.
ZTS switches are available in open type construction for
switchboard installation or NEMA enclosed to the customers
specifications. The power panel components, consisting of
power switching contacts, drive mechanism and terminal lugs, are
mounted on a specially formed panel. Logic devices including mi-
croprocessor control auxiliary time delays and special accessory Drive Mechanism
equipment are assembled on the door for ease of maintenance All GE Zenith ZTS switches employ the simple over-center princi-
and separation from the power section. They are connected with a ple to achieve a mechanically locked position in either normal or
numbered wiring harness equipped with a disconnect plug that al- emergency. GE Zeniths high speed drive assures contact transfer
lows isolation of the control panel for maintenance. in 100 ms or less. High contact pressure and positive mechanical
ZTS Model Operation lock allow for high withstand and closing ratings, far exceeding
UL requirements. All ATS units are listed with UL umbrella breaker
When the normal source fails or the voltage drops to a predeter- and current limiting fuse ratings.
mined point (usually 80% of nominal), if required, a circuit is
closed to start the engine generator set. When the emergency Ratings
source reaches 90% of rated voltage and 95% of rated fre- Ratings 40 to 4000 amperes
quency, the drive solenoid is energized through the emergency 2, 3 or 4 Poles
coil control relay, causing the main contacts to disconnect the Open type, NEMA 1, 3R, 4, 4X and 12
load from the normal source and connect it to the emergency Available to 600 VAC, 50 or 60 Hz
source. After the drive solenoid has completed its electrical stroke Suitable for emergency and standby applications on all
and is seated, the emergency coil control relay opens to discon- classes of load, 100% tungsten rated through 400 amps
nect it. The transfer switch is now mechanically locked in the UL 1008 listed at 480 VAC
emergency position. CSA C22.2 No. 178 certified at 600 VAC
When normal voltage is restored to a predetermined point (usu- IEC 947-6-1 listed at 480 VAC
ally 90% of nominal), the control voltage sensing energizes. The Equipment (controls and power section) seismic test qualified to:
normal side coil relay closes, and after the drive solenoid has IBC2009
completed its electrical stroke and is seated, the coil control relay IEEE6932003
opens to disconnect it. The transfer switch is now mechanically
locked in the normal position. Performance Features
Contact transfer speed less than 100 milliseconds
High close-in and withstand capability
Temperature rise test per UL 1008 conducted after overload
and endurance tests - exceeds UL requirements
Available in:
ZTS (utility-generator)
ZTSU (utility-utility)
ZTSG (generator-generator)
ZTSM (manual) configurations

Design and Construction Features


Double throw, interlocked operation
Electrically operated, mechanically held by a simple, over-
center mechanism
Segmented silver tungsten alloy contacts with separate arcing
contacts on 600 amp and above
Arc quenching grids, enclosed arc chambers, and wide contact
air gap for superior source-to-source isolation on all units
Control disconnect switch for safe maintenance
Components accessible for inspection and maintenance with-
out removal of the switch or the power conductors
Mechanical indicator and contact chamber cover designed for
inspection, safety and position designation.

14-16 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Automatic Transfer Switches Section 14
Critical Power Products
Model ZTSD
Model ZTSD Automatic Transfer Switches
The ZTSD Model provides an adjustable time delay after the open- N E
ing of the closed contacts and before the closing of the open con-
tacts for transferring large motor and/or transformer loads. This
1 Open 2
delayed transition time allows for motors to coast down and
transformer fields to decay, thus allowing inductive loads to be re-
energized after transfer with only normal inrush starting currents.
The delayed transition design is an effective method of handling
these applications and can be utilized as an alternative to a stan-
dard transfer switch equipped with an in-phase monitor. L
The delayed transition transfer switch is ideally suited for pump-
ing stations, sewage treatment plants, hospital X-ray equipment,
or wherever the bulk of the load being controlled consists of
Ratings
large motors and/or transformers. Major UPS manufacturers
strongly recommend the use of delayed transition type transfer Ratings 40 to 4000 amperes
switches to ensure proper operation of their rectifier circuit and 2, 3 or 4 Poles
battery system. Open type, NEMA1, 3R, 4, 4X and 12
Available to 600 VAC, 50 or 60 Hz
The ZTSD Model allows a UPS system sufficient delay to recognize Suitable for emergency and standby applications on all classes
a power failure and transfer to batteries, acknowledge the return of load, 100% tungsten rated through 400 amps
of power and allow the rectifier to walk onto the new source, re- UL 1008 listed at 480 VAC
ducing any transfer anomalies. CSA C22.2 No. 178 certified at 600 VAC
Except for the delayed transition period, the performance, operat- IEC 947-6-1 listed at 480 VAC
ing capabilities, ratings, UL listings, with-stand current values and Equipment (controls and power section) seismic test qualified to:
available options are identical to those of the GE Zenith ZTS Series IBC2009
Automatic Transfer Switches. IEEE6932003
The ZTSD incorporates all of the important features of the stan-
dard ZTS Series switches as well as features oriented toward its Performance Features
specific operation. Adjustable center-off time to meet specific installation
requirements
High close-in and withstand capability
Temperature rise test per UL 1008 conducted after overload and
endurance tests - exceeds UL requirements
Available in:
ZTSD (utility-generator)
ZTSDU (utility-utility)
ZTSDG (generator-generator)
ZTSDM (manual) configurations

Design and Construction Features


Mechanically interlocked center-off position for load decay
Electrically operated, mechanically held by a simple, over-center
mechanism
Segmented silver tungsten alloy contacts with separate arcing
contacts on 600 amp and above
Arc quenching grids, enclosed arc chambers, and wide contact
air gap for superior source-to-source isolation on all units
Control circuit disconnect plug and drive inhibit switch for safe
maintenance
Components accessible for inspection and maintenance without
removal of the switch or the power conductors
ZTSD Mechanical indicator and contact chamber cover designed for
Delayed Transition Transfer Switch inspection, safety and position designation
400 amp, 3 pole
(shown)

Rev. 11/13 www.geindustrial.com BuyLog Catalog 14-17


Data subject to change
without notice
Automatic Transfer Switches Section 14
Critical Power Products
Model ZTSCT

Model ZTSCT Closed Transition Transfer Switches


An automatic transfer switch is the single vital link between utility
and alternate power supplies. Yet it is the very operation and re-
transfer back to normal that may be the cause of concern for
many users. Loads such as electronic equipment, HID lighting,
motor starters, etc., are sensitive to even the 30-100 millisecond
outage experienced during a typical transfer switch operation.
Therefore, testing and use of the standby system is not optimized
and necessary system checks are not performed because of con-
cerns about the effects of transfer. Closed transition operation takes place when both sources are
within preset voltage and frequency parameters and the phase
In addition to these applications, opportunities for peak shaving
angle differential is less than five degrees. The closed transition
and utility incentive rates may be passed over because of the in-
sequence may be initiated by the test switch, a load exerciser
ability to accept the short power interruptions inflicted during op-
clock, peak shaving controls or special utility incentive rate signals.
eration. In response to the needs of these installations, GE Zenith
offers the ZTSCT Closed Transition Transfer Switch and ZBTSCT
Closed Transition Transfer/Bypass Switch. Ratings
These products utilize the proven switching technology of the Ratings 100 to 4000 amperes
ZTS/ZTSD Models of transfer switches combined with controls 2, 3 or 4 Poles
developed during GE Zeniths years of experience in the manufac- Open type, NEMA 1, 3R, 4, 4X and 12
ture of synchronizing switchgear. They provide the capability to Available in Transfer Switch (ZTSCT) or Transfer/Bypass
transfer in a closed transition mode when both sources are within Switch (ZBTSCT) styles
preset parameters. Utilizing GE Zeniths high speed drive system, Suitable for emergency and standby applications on all
the overlap of the normal and alternate sources is less than 100 classes of load, 100% tungsten rated through 400 amps
milliseconds. When one source is not within specified limits, such UL 1008 listed at 480 VAC
as during a power failure, the ZTSCT operates in an open transi- CSA certified at 600 VAC
tion mode. IEC listed at 480 VAC
Equipment (controls and power section) seismic test qualified to:
Description and Operation
IBC2009
Closed transition switches have two basic modes of operation. IEEE6932003
During a failure of one source or an out of specification condition,
the ZTSCT Model operates as a delayed transition switch (ZTSD Performance Features
Model). This sequence allows clear separation of an unreliable
Incorporates the applicable features of the ZTS and ZBTS Series
source from an available one.
Source parallel time of less than 100 milliseconds
Closed transition operation (no power interruption) during
transfer and retransfer when sources are within specified
parameters
Open transition transfer operation is initiated upon a source
failure
Available in:
ZTSCT (utility-generator)
ZTSCTU (utility-utility)
ZTSCTM (manual) configurations

Design and Construction Features


Electrically operated, mechanically held
Segmented silver tungsten alloy contacts with separate arcing
contacts on 600 amps and above
Arc quenching grids, enclosed arc chambers, and wide contact
air gap
Components accessible for inspection and maintenance with-
out removal of the switch or the power conductors
Standard annunciation and operational selection package for
ZTSCT user interface
Closed Transition Transfer Switch Active control of the generator governor not required, but is
800 amp, 3 pole available as an option

14-18 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Automatic Transfer Switches Section 14
Critical Power Products
Models ZBTS, ZBTSD and ZBTSCT

Models ZBTS, ZBTSD and ZBTSCT Bypass-Isolation


Transfer Switches
The ZBTS Model Bypass-Isolation Transfer Switch consists of two
major modules the automatic transfer and the bypass-isolation
switch. The automatic transfer switch module is the proven
GE Zenith ZTS Series, built in ZTS, ZTSD or ZTSCT configuration and
constructed for reliable operation. The same components, heavy-
duty silver alloy contacts, rugged drive mechanism and
silver plated bus bar inter-connections are used throughout the
ZBTS Model.
The bypass section is a basic ZTS switch provided with a quick
make/quick break manual load transfer handle and GE Zeniths 1. Automatic: The transfer switch is carrying the load, and the by-
control/interlock system consisting of both mechanical and pass switch is in the open position. This is the normal operating
electrical interlocks. The bypass is equipped with normal failure mode.
sensing and a time delay to start the engine automatically if 2. Test: The bypass switch is closed and feeding the load.
the ATS has been removed for service and a failure occurs. The The transfer switch has control power and may be operated
modules are mounted in a compact enclosure and completely in- for test purposes via the test switch on the enclosure door.
terconnected requiring only the normal source, emergency source
and load cable connections. Once installed, no cables 3. Isolate: The transfer switch is withdrawn from all power and
ready for maintenance. The load is served by the bypass
need to be removed to isolate the transfer switch module for
switch.
maintenance or inspection. The automatic transfer switch may
be withdrawn for testing or maintenance without disturbing the The ZTS Transfer Switch is installed on a draw-out mechanism,
load. The transfer switch module has three positions: with electrical and mechanical interlocks for secure removal after
the load has been bypassed. The ZTS control/logic panel is
mounted on the enclosure door and connected by a wire harness
and multi-pin disconnect plugs. The transfer switch and/or the
control panel may be tested, isolated and removed for maintenance
without load interruption.
The bypass-isolation switch module is the same basic design as
the transfer switch module and has the same electrical ratings.
Manually operated, it features high speed, quick make/quick
break contact action. The bypass-isolation switch has three basic
positions:
1. Automatic: Normal bypass contacts open, emergency bypass
contacts open.
2. Bypass Normal: Normal bypass contacts closed, emergency by-
pass contacts open.
3. Bypass Emergency: Normal bypass contacts open, emergency
bypass contacts closed.
GE Zeniths design requires no additional load break contacts
which cause load interruption during bypass-isolation functions.
The bypass-isolation switch contacts are out of the system
ZBTS current path except during actual bypass operation.
Transfer/Bypass-Isolation Transfer Switch Therefore, they are not constantly exposed to the destructive ef-
1200 amp, 3 pole fects of potential fault currents. The normal, emergency and load
(shown) are connected between the automatic transfer switch and the by-
pass-isolation switch through solidly braced isolating
contacts that are open when the transfer switch is isolated.
All current carrying components provide high withstand current
ratings in excess of those specified in UL 1008 standards.

Rev. 11/13 www.geindustrial.com BuyLog Catalog 14-19


Data subject to change
without notice
Automatic Transfer Switches Section 14
Critical Power Products
Models ZBTS, ZBTSD and ZBTSCT

Models ZBTS, ZBTSD and ZBTSCT Bypass-Isolation Transfer Ratings


Switches (Continued) Ratings 100 to 4000 amperes
Interlocks and Indicators 2, 3 or 4 Poles
Open type, NEMA 1, 3R, 4, 4X and 12
Every ZBTS Model Bypass-Isolation Transfer Switch is supplied
Available with ZTS, ZTSD and ZTSCT Series Transfer Switch
with all necessary electrical and mechanical interlocks to prevent
Bypass and transfer switch have identical ratings
improper sequence of operation as well as the necessary inter-
Suitable for emergency and standby applications on all classes
locking circuit for engine starting integrity. Each ZBTS is furnished
of load, 100% tungsten rated through 400 amps
with a detailed step by step operating instruction plate as well as
UL 1008 listed at 480 VAC
the following functional diagnostic lights:
CSA C22.2 No. 178 certified at 600 VAC
Normal Source Available IEC 947-6-1 listed at 480 VAC
Emergency Source Available Equipment (controls and power section) seismic test qualified to:
Bypass Switch in Normal Position IBC2009
Bypass Switch in Emergency Position IEEE6932003
Automatic Transfer Switch in Test Position
Automatic Transfer Switch Isolated Performance Features
Automatic Transfer Switch Inhibit Load is not interrupted during bypass operation
Automatic Transfer Switch Operator Disconnect Switch Off High close-in and withstand capability
Automatic Transfer Switch in Normal Position Temperature rise test per UL 1008 conducted after overload
Automatic Transfer Switch in Emergency Position and endurance tests - exceeds UL requirements
Available in:
ZBTSCT Model Closed Transition
ZBTS (utility-generator)
Transfer/Bypass-Isolation Switches
ZBTSU (utility-utility)
The ZTSCT Closed Transition Transfer Switch may be applied with ZBTSG (generator-generator)
a bypass-isolation switch for the utmost in reliability and versatil- ZBTSM (manual) configurations; models include standard,
ity. The ZBTSCT Series provides the ability to withdraw the transfer delayed and closed transition
switch unit for maintenance or inspection. Reference the ZTSCT
unit features and operational description for more details. Design and Construction Features
ZBTSD Model Delayed Transition Transfer switch is located on a draw out mechanism to
Transfer/Bypass-Isolation Switches facilitate maintenance
The ZTSD Delayed Transition Transfer Switch with a timed center- Emergency power systems can be electrically tested without
off position is available in a bypass configuration. The ZBTSD Se- disturbing the load
ries Bypass incorporates the features of both the ZBTS Power cables do not have to be disconnected to remove the
Bypass-Isolation Switch and the ZTSD unit for transfer of large transfer switch
motor loads, transformers, UPS systems or load shedding to a Bypass to any available source with transfer switch removed
neutral Off position. Reference the ZTSD unit features and oper- Engine start circuit maintained during bypass operation; normal
ational description for more details. power failure causes engine start contact closure even with the
ATS removed
Diagnostic lights and detailed instructions for simple step-by-
step operation
Mechanical and electrical interlocks ensure proper sequence
of operation
Bypass switch contacts are closed only during the bypass-
isolation operation
Silver plated copper bus interconnection of the transfer and by-
pass switches on all sizes

14-20 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Automatic Transfer Switches Section 14
Critical Power Products
MX250 Microprocessor Controller

Automatic Transfer Switch Controller


With more powerful integrated features, the new MX250 Micro-
processor, standard with the entire ZTS product family, offers
expanded programmability and field adaptability. This premium
product is designed for use in specification-grade applications.
As an embedded digital controller, the MX250 offers high
reliability and ease of unattended operation across a range
of applications.

Available in ALL transfer modes: LOAD DISCONNECT TD


Open, Delayed and Bypass
PRE XFR
Closed
User-friendly programmable engine exerciser, used for the TIME REMAINING 04:02
engine generator with or without load, at ANY interval in a MOR E
one-year period
Operating voltages available in a single controller for most
domestic and international applications
Real-time display of ATS status, including active timer(s)
Multiple levels of user-defined password protection
Serial communications allowing connectivity with other ATS's,
paralleling switchgear, and SCADA systems
Time-tested synchronous logic automatically measures
phase angle and frequency allowing disturbance-free transfer Entelli-Switch 250
Unsurpassed statistical ATS/System monitoring available in
real-time
T3/W3 elevator pre-signal. Automatically bypassed if the se-
lected source fails, minimizing time an elevator is without power
Universal Motor Disconnect (UMD) sends a pre-signal, The control operates off a close differential 3 phase under-voltage
post-signal or both to any motor control center. Not bypassed in sensing of source 1, factory standard setting 90% pickup, 80%
an outage, the UMD ensures safety in the event of a single dropout; under-frequency sensing of source 1 factory setting 95%
phase loss pickup; voltage and frequency sensing of source 2, factory standard
Voltage unbalance detection standard setting 90% pickup voltage, 95% pickup frequency. All factory settings
Imbedded synchoscope with display to ensure smooth transfer are operator adjustable see table on reverse side).
Performance Features
A test is standard (fast test/load/no load) to simulate source 1 failure -
UL, CSA and IEC listed automatically bypassed should source 2 fail.
Ringing wave immunity per IEEE 472 (ANSI C37.90A)
Condusted and Radiated Emissions per EN55022 Class B
(CISPR 22) (Exceeds EN55011 and MILSTD 461 Class 3)
ESD Immunity test per EN61000-4-2 (Level 4)
Radiated RF, electromagnetic field immunity test per
EN61000-4-3 (ENV50140) 10v/m
Electrical fast transient/burst immunity test for EN61000-4-4
Surge immunity test per EN61000-4-5 IEEE C62.41 (1.2 x 50s,
0.5 and 4 kV)
Conducted immunity test per EN61000-4-6 (ENV50141)
Voltage dips and interruption immunity EN61000-4-11

User-Friendly Operation
LEDs are used in a recognizable line configuration for continuous
monitoring of switch position. A new LCD display shows source
availability, exercise time delay operation and system source
condition. A new simplified adjustment is featured for voltage,
frequency and time delay settings.

Rev. 11/13 www.geindustrial.com BuyLog Catalog 14-21


Data subject to change
without notice
Automatic Transfer Switches Section 14
Critical Power Products
ZTS Series
ZTS Series Accessory Definitions
6P Microprocessor activated test switch (Momentary) M90 EPM2000 True RMS Digital Meter with display (Amps, Volts,
6A Hardwired test switch (Maintained) Power, Energy, Power Factory and Frequency). 3 Line LED
Display. 50/60 Hz Universal Operation. 1 or 3 phase.
6AP Microprocessor activated test switch (Maintained) Standard Modbus RTU RS485 communications
6B Hardwired test switch (Maintained Auto - Momentary capability. 40 - 1200 Amps.
Test) Key operated M90A Adds Pre-Wiring for Enervista Viewpoint Monitoring of
6C Hardwired test switch (Maintained Auto - Maintained M90 Accessory & ATS Status using Modbus RS485 Serial
Test) Key operated Communications
A1 Auxiliary Contact S.P.D.T. - Normal (Source 1) Failure M90B Adds Pre-Wiring for Enervista Viewpoint Monitoring of
A1E Auxiliary Contact S.P.D.T. - Emergency (Source 2) Failure M90 Accessory & ATS Status using Ethernet TCP/IP
Communications
A3 Auxiliary Contact - closed in emergency (Source 2) Addi-
tional available (10 max.) on ZTS Series and need to be M91 EPM6000 True RMS Digital Meter with display (Amps,
specified Volts, Power, Energy, Power Factory and Frequency,
THD). Certified energy and demand metering. Meets
A4 Auxiliary Contact - closed in normal (Source 1) Additional
ANSI C12.20 and IEC 687 Accuracy Classes. Front LRDA
available (10 max.) on ZTS Series and need to be
Port Laptop Connection. Standard Modbus RTU RS485
specified
or DNP 3.0 communications capability.
A62 Motor disconnect and staged restart (1 contact)
M91A Adds Pre-Wiring for Enervista Viewpoint Monitoring of
AB3 Auxiliary Contact - closed in bypass emergency (Source 2) M91 Accessory & ATS Status using Modbus RS485 Serial
(S.P.T.D.) (Standard up to 400A) Additional available (10 Communications
max.) on ZBTS Series and need to be specified
M91B Adds Pre-Wiring for Enervista Viewpoint Monitoring of
AB4 Auxiliary Contact - closed in bypass normal (Source 1) M91 Accessory & ATS Status using Ethernet TCP/IP
(S.P.T.D.) (Standard up to 400A) Additional available (10 Communications
max.) on ZBTS Series and need to be specified
MCM Modbus RTU Communication Module
Calibrate Microprocessor activated calibration feature
N1 Running Time Indicator - Door mounted
CDP Programmable exerciser daily, 7/14/28/365 days user-
N2 Operation Counter - Door Mounted
selectable, with or without load
P1 Engine Start Timer (adjustable to 6 sec.)
CDT Exerciser no load timer
P2 Engine Start Timer (adjustable to 300 sec.)
CTAP Chicago transfer alarm panel mounted in door of
enclosure. Includes 3 aux. contacts and fuse. Q2 Peak shave/remote load test/area protection - Relay
(S.P.D.T.) (Need to specify voltage - 120 VAC, 24 VAC, 24
DS Disconnect Switch. Disconnects source voltage to trans-
VDC - 120V default standard)
fer power panel.
Q3 Inhibit transfer to emergency (Source 2) (load add relay)
DT (Delayed Transition Only) Time Delay from Neutral Switch
- Relay (S.P.D.T.) (Need to specify voltage - 120 VAC, 24
position to Source 1 on retransfer
VAC, 24 VDC - 120V default standard)
DW (Delayed Transition Only) Time Delay from Neutral Switch
Q7 Inhibit transfer to normal (Source 1) - Relay (S.P.D.T.) (Need
position to Source 2 on retransfer
to specify voltage - 120 VAC, 24 VAC, 24 VDC - 120V default
E Engine Start Relay standard)
ECM Ethernet Communication Adapter. Requires MCM (Modbus) R1-1/R1-3 Over Voltage sensing for normal (Source 1) single (R1-1)
Accessory. or three (R1-3) phase
EL/P Event log of last 16 events R15/R15D Load Shed. Should Source 2 become overloaded, a
F Fan contact, closed when engine runs. signal can be given to switch to the Neutral position.
HT(1)(2) Heater and Thermostat 208/240V (1) 380/600V (2) R16 Phase rotation sensing of Normal (Source 1) and Emergency
mounted and interwired in enclosure. (requires larger (Source 2)
enclosure for 40-200A) R26/R26D Interruptable Power Rate Provisions. Allow transfer out
K Frequency Meter (Analog) - Door mounted of Source 1 position to Mid position or dead Source 2.
K/P Frequency Indication on the controller Alarm and Pre-Signal circuit included. (Need to specify
voltage - 120 VAC, 24 VAC, 24 VDC - 120V default
LNP Center-off position LCD-Indicator
standard)
L1 LED light indicates Switch in Source 2 position
R50 In Phase monitor between Normal (Source 1) and Emer-
L2 LED light indicates Switch in Source 1 position gency (Source 2) to allow transfer
L3 LED light indicates Source 1 available S5P Microprocessor activated auto/manual retransfer
L4 LED light indicates Source 2 available selector switch for trnsferring to Normal (Source 1)
LCM LonWorks Communication Module (includes microprocessor activated YN accessory)
M1 Single Phase Amp Meter (Analog) S12P Microprocessor activated auto/manual retransfer
selector switch for trnsferring to Normal (Source 1)
M2 Three Phase Amp Meter (Analog) (includes microprocessor activated YN & YE accessory)

14-22 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Automatic Transfer Switches Section 14
Critical Power Products
ZTS Series
ZTS Series Accessory Definitions (continued)
S13P Microprocessor activated commit/no commit on trans- T Retransfer to Normal (Source 1) adjustable time delay
ferring to Emergency (Source 2) (with enable/disable T3/W3 Pre-signal contact on transfer to Normal (Source 1) or
settings) Emergency (Source 2) during test
S14 Keyed selector switch for retransfer to normal-test-auto U Engine stop /cool adjustable cool down timer
SW1 Auto/Off/Start Engine control selector - Door mounted UMD Pre and ppost transfer output adjustable time range.
(keyed or non-keyed operation available) Functions in both directions. Includes 2 circuits. (Additional
SW2 Auto/Off Engine control selector - Door mounted (keyed circuits available).
or non-keyed operation available) VI Voltage imbalance between phases (3 Phase only)
SW3 Source Priority Selector Switch - Door mounted W Adjustabvle time delay on transfer to Emergency
Allows selection of Source 1 or Source 2 to be the Prime (Source 2)
Source. Transfer Switch will transfer to selected Prime
YEN Bypass transfer timers function (soft key switch in micro-
Source if that Source is available. (keyed or non-keyed
processor)
operation available)

ZTS Series Accessory Group Matrix


Group Packages
Accessories
MSTD MEXE MCON MSEN MSPE MPSG
6P
A1
A1E
A3 2 2 2 2 3
A4 2 2 2 2 3
Calibrate
CDT
CDP
**DS
*DT
*DW
E
EL/P
K/P
L1
L2
L3
L4
*LNP
P1
Q2
Q3
Q7
R1-1
R1-3
R15
*R15D
R16
R50
S5P
S12P
S13P
T
T3/W3 2 2 2 2 2 2
U
UMD 2 2 2 2 2 2
VI
W
YEN

Standard Accessory included in the group package.


Optional Accessory not included but can be added to group package.
Optional Accessory. Can not be used with accessory having the same symbol.
N/A
2 2 Denotes an Accessory with 2 circuits as a standard.
3 Denotes an Accessory with 3 circuits as a standard.
* Delayed Transition Units Only.
** Optional for 40-400 Amp

Rev. 11/13 www.geindustrial.com BuyLog Catalog 14-23


Data subject to change
without notice
Automatic Transfer Switches Section 14
Critical Power Products
ZTS Series
ZTS Series Ordering Information

Z B 0 Z E C Z V C
Model/Type Control Application Ampere Size Switched Enclosure Type Operational Voltage Accessories
Panel Poles

Z T S 0 0 0 B 0 0 0 0 4 B 0 1 A B M S T D
Standard (Open Transition) Entelli-Switch 250 Utility - Generator 40 amps 2 Poles Type 1 Enclosed Consult Table Below
Microprocessor
Control Unit M E X E
Z T S D 0 0 U 0 0 8 E 1 2
Delayed Transition Utility - Utility 80 amps 3 Poles Type 12 Enclosure
M C O N
Z T S C T 0 M 0 1 0 F 3 R
Closed Transition 100 amps Type 3R Enclosure
M S E N
Manual 4 Poles

Z B T S 0 0 G 0 1 5 4 0 M S P E
Standard (Open Transition) w/Bypass Gen to Gen 150 amps Type 4 Enclosure
M P S G
Z B T S D 0 0 2 2 4 X
Delayed Transition w/Bypass 225 amps Type 4X Enclosure M A N 0
Z B T S C T 0 2 6 0 0
Closed Transition w/Bypass Then choose
260 amps
Open Style Unit additional accessories

0 4 0
Switch Types 400 amps
A B Voltage Phase ConWg. Hz
Standard: Unless otherwise noted, the 1 0 120 1 2 wire 60
standard switch with quick transfer will 0 6 0 2 0 120/240 1 3 wire 60
600 amps 2 1 120/208 1 3 wire 60
be supplied. 3 0 240 3 3 wire 60
Delayed Transition: When ordered as the 0 8 0 3 1 208 3 3 wire 60
ZTSD, the delayed transition switch offers 800 amps 3 2 220 3 3 wire 50
3 3 120/240 3 4 wire 50
time delay during transfer from one position 1 0 0 3 4 110/220 3 4 wire 60
to the other. This is primarily for transfer of 1000 amps
3 5 139/240 3 4 wire 60
3 8 120/240 3 4 wire 60
large motor or inductive loads.
4 0 120/208 3 4 wire 60
Closed Transition: When ordered as the 1 2 0 4 1 127/220 3 4 wire 60
1200 amps
ZTSCT, the closed transition switch offers 4 2 127/220 3 4 wire 50
5 0 480 3 3 wire 60
two basic modes of operation. During a 1 6 0 5 1 440 3 3 wire 60
failure of one source or an out of specifica- 1600 amps 5 2 440 3 3 wire 50
tion condition, the ZTSCT Model operates 5 5 460 1 3 wire 50
2 0 0 5 7 480 1 2 wire 60
as a standard delayed transition switch 5 8 254/440 3 4 wire 60
2000 amps
(ZTSD Model). This sequence allows clear 6 0 575 3 3 wire 60
3 0 0 6 1 347/600 3 4 wire 60
separation of an unreliable source from an
7 0 277/480 3 4 wire 60
available one. 3000 amps
7 1 277 1 2 wire 60
Bypass: When ordered as the ZBTS, the 4 0 0
7 4 266/460 3 4 wire 60
7 5 460 3 3 wire 60
bypass transition switch offers a draw-out 4000 amps 8 0 120/240 2 4/5 wire 60
mechanism, with electrical and mechanical 8 2 380 1 2 wire 50
interlocks for secure removal after load by- 9 0 240/416 3 4 wire 60
9 1 220/380 3 4 wire 60
pass. In this way the transfer switch and/or 9 2 220/380 3 4 wire 50
the control panel may be tested, isolated 9 3 240/416 3 4 wire 50
9 7 380 3 3 wire 60
and removed for maintenance without
load interruption. Note: Operating voltage must be specified at time of order.
Only the most common voltages are shown above.
Product # Example
ZTSCT0B00040F-ZEC01ZVC40MSTD
This number string shows the correct format for a ZTS Model Auto-
matic Transfer Switch with closed transition, an Entelli-Switch 250
microprocessor control unit, Utility - Generator, 400 amps, 4 pole,
NEMA Type 1 enclosure, 120/208V 3F, 4 wire, 60 Hz system with
the standard group of accessories.
UL 1008 Withstand and Closing Ratings
Please refer to GE Zenith Controls Bulletin TB-1102.

14-24 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Automatic Transfer Switches Section 14
Critical Power Products
ZTS Series
ZTS Model, Dimensions and Weights
NEMA 1 Weight
Reference Open Application
Ampere Rating Poles Height (A) Width (B) Depth (C) Figure Type NEMA 1 Notes
2, 3 24 (61) 18 (46) 11 (28) A 21 (10) 57 (26)
40, 80 1 - 7, 11-14
4 24 (61) 18 (46) 11 (28) A 21 (10) 60 (27)
2, 3 24 (61) 18 (46) 11 (28) A 21 (10) 57 (26)
100, 150 1 - 7, 11-14
4 24 (61) 18 (46) 11 (28) A 21 (10) 60 (27)
2, 3 46 (117) 24 (61) 14 (36) A 70 (32) 165 (75)
225 1 - 7, 12-14
4 46 (117) 24 (61) 14 (36) A 75 (34) 170 (68)
2, 3 46 (117) 24 (61) 14 (36) A 70 (32) 165 (75)
260, 400 1 - 7, 12-14
4 46 (117) 24 (61) 14 (36) A 75 (34) 170 (68)
2, 3 74 (188) 40 (102) 19.5 (50) B 165 (75) 380 (172)
600 1 - 8, 12-14
4 74 (188) 40 (102) 19.5 (50) B 185 (84) 430 (195)
2, 3 74 (188) 40 (102) 19.5 (50) B 190 (86) 455 (206)
800, 1000, 1200 1 - 8, 12-13
4 74 (188) 40 (102) 19.5 (50) B 210 (95) 540 (245)
3 90 (229) 35.5 (90) 48 (122) C 345 (156) 1010 (458)
1600, 2000 1 - 13
4 90 (229) 35.5 (90) 48 (122) C 450 (204) 1160 (526)
3 90 (229) 35.5 (90) 48 (122) C 465 (211) 1130 (513)
3000 1 - 13
4 90 (229) 35.5 (90) 48 (122) C 670 (304) 1395 (633)
3 90 (229) 46.5 (118) 60 (152) C 770 (349) 1595 (723)
4000 1 - 13
4 90 (229) 46.5 (118) 60 (152) C 1025 (465) 1850 (839)

Application Notes: C B
C B
1. Metric dimensions (cm) and weights (Kg) shown in parenthesis
adjacent to English measurements in inches and pounds.
2. Includes 1.25" door projection beyond base depth. Allow a mini-
mum of 3" additional depth for projection of handle, light,
switches, pushbuttons, etc. A
A
3. All dimensions and weights are approximate and subject to
change without notice.
4. Special enclosures (NEMA 3R, 4, 12, etc.) dimensions and
layout may differ. Consult the GE Zenith factory for details.
5. Normal and emergency may be ordered inverted on any switch. Figure A Figure B
The load may be inverted 600-1200 amps. Consult the GE Zenith
factory for details. C B
6. Special lug arrangements may require different enclosure dimen-
sions. For certified drawings, contact the GE Zenith factory.
7. Packing materials must be added to weights shown. Allow 15%
additional weight for cartons, skids, crates, etc.
8. Add 4" in height for removable lifting lugs. A
9. Lug adapters for 3000-4000 amp limits may be staggered length
for ease of entrance. Consult the ge Zenith factory for details.
10. Ventilation louvers on both sides and rear of enclosure. Louvers
must be clear for airflow with standard cable connections.
11. A ZTS 40-150A, when ordered with the following options, will re-
quire a larger enclosure of 46" x 24" x 14" (HxWxD): A62(T), Digital Figure C
Meter, HT, HH, K, LDS, L11, N1, N2, OCVR-1SG, OCVR-1SS, P2,
Q2M, Q3M, Q7M, R26(D). AL-CU UL Listed Solderless Screw-Type Terminals
12. For Delayed and Closed Transition dimensions and weights, refer for External Power Connections
to GE Zenith Publication PB-5067 and PB-5069. Normal, & Load Terminals
Switch Size Amps Cables/Pole Wire Ranges
13. For Bypass/Isolation dimensions and weights, refer to GE Zenith
40-80 1 #8 to 3/0
Publication pb-5068. 100, 150 1 #6 to 250 MCM
14. A ZTS, when ordered with compression lugs suitable for use with 225 1 #4 to 600 MCM
copper cables, will require a larger enclosure. For 40-225A, the 260 1 #4 to 600 MCM
400 1 #4 to 600 MCM
enclosure is 46" x 24" x 14" (HxWxD). For 260-400A, the enclosure 600 2 #2 to 600 MCM
is 66" x 24" x 19.75". For 600A, the enclosure is 74" x 40" x 19.75". 800, 1000, 1200 4 #2 to 600 MCM
For certified drawings, please contact the GE Zenith factory. 1600, 2000,3000, 4000 *

Notes
* Line and load terminals are located in rear and arranged for bus bar connection. Terminal lugs are available as an accessory. Contact GE Zenith factory for more details.
1. Special terminal lugs and neutral bars are available at additional cost. Contact factory and advise cable sizes and number of conductors per pole.
2. Fully rated neutral provided on 3 phase, 4 wire system.
3. Special lug arrangements may require different enclosure dimensions. For certified drawings, contact the GE Zenith factory.

Rev. 11/13 www.geindustrial.com BuyLog Catalog 14-25


Data subject to change
without notice
Automatic Transfer Switches Section 14
Critical Power Products
ZTS Series
ZTS Series Dimensional Specifications
Model ZTS Transfer Switches
NEMA 1 Enclosure Weight
Ampere Rating Poles Height (A) Width (B) Depth (C) Ref. Fig. Open Type NEMA 1 App. Notes
2, 3 24 (61) 18 (46) 11 (28) A 21 (10) 57 (26) 1 7, 11 - 14
40, 80, 100, 150,
4 24 (61) 18 (46) 11 (28) A 21 (10) 60 (27) 1 7, 11 - 14
2, 3 46 (117) 24 (61) 14 (36) A 70 (32) 165 (75) 1 7, 12 - 14
225, 260, 400
4 46 (117) 24 (61) 14 (36) A 75 (34) 170 (68) 1 7, 12 - 14
2, 3 74 (188) 40 (102) 19.5 (50) B 165 (75) 380 (172) 1 8, 12 - 14
600
4 74 (188) 40 (102) 19.5 (50) B 185 (84) 430 (195) 1 8, 12 - 14
2, 3 74 (188) 40 (102) 19.5 (50) B 190 (86) 455 (206) 1 8, 12 - 13
800, 1000, 1200
4 74 (188) 40 (102) 19.5 (50) B 210 (95) 540 (245) 1 8, 12 - 13
3 90 (229) 35.5 (90) 48 (122) C 345 (156) 1010 (458) 1 13
1600, 2000
4 90 (229) 35.5 (90) 48 (122) C 450 (204) 1160 (526) 1 13
3 90 (229) 35.5 (90) 48 (122) C 465 (211) 1130 (513) 1 13
3000
4 90 (229) 35.5 (90) 48 (122) C 670 (304) 1395 (633) 1 13
3 90 (229) 46.5 (118) 60 (152) C 770 (349) 1595 (723) 1 13
4000
4 90 (229) 46.5 (118) 60 (152) C 1025 (465) 1850 (839) 1 13

Application Notes:
1. Metric dimensions (cm) and weights (Kg) shown in parenthesis adjacent to English measurements in inches and pounds.
2. Includes 1.25" door projection beyond base depth. Allow a minimum of 3" additional depth for projection of handle, light, switches, pushbuttons, etc.
3. All dimensions and weights are approximate and subject to change without notice.
4. Special enclosures (NEMA 3R, 4, 4X, 12, etc.) dimensions and layout may differ. Consult the GE Zenith factory for details.
5. Normal and emergency may be ordered inverted on any switch. The load may be inverted 600-1200 amps. Consult the factory for details.
6. Special lug arrangements may require different enclosure dimensions. For certified drawings, contact the GE Zenith factory.
7. Packing materials must be added to weights shown. Allow 15% additional weight for cartons, skids, crates, etc.
8. Add 4" in height for removable lifting lugs.
9. Lug adapters for 3000-4000 amp limits may be staggered length for ease of entrance. Consult the GE Zenith factory for details.
10. Ventilation louvers on both sides and rear of enclosure. Louvers must be clear for airflow with standard cable connections.
11. A ZTS 40-150A, when ordered with the following options, will require a larger enclosure of 46x 24x 14 (HxWxD): A62(T), Digital Meter HT, HH, K, LDS, L11, N1, N2, OCVR-
1SG, OCVR-1SS, P2, Q2M, Q3M, Q7M, R26(D).
12. For Delayed and Closed Transition dimensions and weights, refer to GE Zenith publication PB-5067 and PB-5069.
13. For Bypass/Isolation dimensions and weights, refer to GE Zenith publication PB-5068.
14. A ZTS, when ordered with compression lugs suitable for use with copper cables will require a larger enclosure. For 40-225A, the enclosure is 46 x 24 x 14 (H x W x D). For
260-400A, the enclosure is 66 x 24 x 19.75. For 600A, the enclosure is 74 x 40 x 19.75. For certified drawings, please contact the GE Zenith factory.

Model ZTSD Transfer Switches


NEMA 1 Enclosure Weight
Ampere Rating Poles Height (A) Width (B) Depth (C) Ref. Fig. Open Type NEMA 1 App. Notes
2, 3 46 (117) 24 (61) 14 (36) A 80 (36) 200 (91) 1 - 7, 11 - 13
40, 80, 100, 150, 225, 260, 400
4 46 (117) 24 (61) 14 (36) A 85 (39) 205 (93) 1 7, 11 - 13
2, 3 74 (188) 40 (102) 19.5 (50) B 185 (84) 400 (181) 1 8, 12 - 13
600
4 74 (188) 40 (102) 19.5 (50) B 205 (93) 450 (204) 1 8, 12 - 13
2, 3 74 (188) 40 (102) 19.5 (50) B 210 (95) 475 (215) 1 8, 12 - 13
800, 1000, 1200
4 74 (188) 40 (102) 19.5 (50) B 230 (104) 560 (254) 1 8, 12 - 13
3 90 (229) 35.5 (90) 48 (122) C 365 (166) 1030 (467) 1 8, 10, 12 - 13
1600, 2000
4 90 (229) 35.5 (90) 48 (122) C 470 (213) 1190 (540) 1 8, 10, 12 - 13
3 90 (229) 35.5 (90) 48 (122) C 485 (220) 1150 (522) 1 10, 12 - 13
3000
4 90 (229) 35.5 (90) 48 (122) C 690 (313) 1415 (642) 1 10, 12 - 13
3 90 (229) 46.5 (118) 60 (152) C 802 (372) 1635 (742) 1 10, 12 - 13
4000
4 90 (229) 46.5 (118) 60 (152) C 1045 (474) 1870 (848) 1 10, 12 - 13

Application Notes:
1 - 9, 11, 13. Same as above
10. Ventilation louvers on both sides and rear of enclosure. One set of louvers must be clear for airflow with standard cable connectors.

Reference Figures

Figure A Figure B Figure C

14-26 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Automatic Transfer Switches Section 14
Critical Power Products
ZTS Series
ZTS Series Dimensional Specifications
Model ZBTS and ZBTSD Transfer/Bypass-Isolation Switches

NEMA 1 Enclosure Weight


Ampere Rating Poles Height (A) Width (B) Depth (C) Ref. Fig. Open Type NEMA 1 App. Notes
2, 3 83 (211) 30 (76) 28.5 (73) D 310 (141) 770 (350) 19
100, 150, 225, 260, 400
4 83 (211) 30 (76) 28.5 (73) D 380 (173) 840 (381) 19
3 90 (229) 36 (91) 28.25 (72) E 660 (299) 1220 (553) 19
600
4 90 (229) 40 (102) 28.25 (72) E 770 (349) 1365 (619) 19
3 90 (229) 40 (102) 28.25 (72) E 765 (347) 1355 (615) 19
800, 1000, 1200
4 90 (229) 46 (117) 28.25 (72) E 910 (413) 1570 (712) 19
3 90 (229) 40 (102) 61.25 (156) F 2900 (1315) 3100 (1406) 17
1600, 2000
4 90 (229) 50 (127) 61.25 (156) F 3800 (1724) 4000 (1814) 1 7, 10
3 90 (229) 40 (102) 73.25 (186) F 3700 (1678) 3900 (1769) 1 7, 10
3000
4 90 (229) 50 (127) 73.25 (186) F 4800 (2177) 5000 (2268) 10 12
3 90 (229) 47.5 (121) 81 (206) F 4310 (1955) 4660 (2113) 1 7, 10 11
4000
4 90 (229) 54 (137) 81 (206) F 5510 (2499) 5860 (2658) 1 7, 10 11

Model ZBTSCT Closed Transition Transfer/Bypass-Isolation Switches


NEMA 1 Enclosure Weight
Ampere Rating Poles Height (A) Width (B) Depth (C) Ref. Fig. Open Type NEMA 1 App. Notes
3 90 (229) 36 (91) 28.25 (72) E 730 (331) 1280 (581) 18
100, 150, 225, 260, 400, 600
4 90 (229) 40 (102) 28.25 (72) E 840 (381) 1385 (628) 18
3 90 (229) 40 (102) 28.25 (72) E 835 (379) 1435 (651) 19
800, 1000, 1200
4 90 (229) 46 (117) 28.25 (72) E 980 (444) 1640 (744) 19
3 90 (229) 40 (102) 61.25 (156) F 2970 (1347) 3170 (1438) 1 7, 10
1600, 2000
4 90 (229) 50 (127) 61.25 (156) F 3870 (1755) 4070 (1846) 1 7, 10
3 90 (229) 40 (102) 73.25 (186) F 3770 (1710) 3970 (1801) 1 7, 10 12
3000
4 90 (229) 50 (127) 73.25 (186) F 4870 (2209) 5070 (2300) 1 - 7, 10 12
3 90 (229) 47.5 (121) 81 (206) F 4380 (1986) 4730 (2145) 1 7, 10 12
4000
4 90 (229) 54 (137) 81 (206) F 5580 (2531) 5930 (2689) 1 7, 10 12

Application Notes:
1. Metric dimensions (cm) and weights (Kg) shown in parenthesis adjacent to English measurements in inches and pounds.
2. Includes 1.25" door projection beyond base depth. Allow a minimum of 3" additional depth for projection of handle, light, switches, pushbuttons, etc.
3. All dimensions and weights are approximate and subject to change without notice.
4. Special enclosures (NEMA 3R, 4, 4X, 12, etc.) dimensions and layout may differ. Consult the GE Zenith factory for details.
5. Bypass Model product can not be ordered with inverted style.
6. Special lug arrangements may require different enclosure dimensions. For certified drawings, contact the GE Zenith factory.
7. Packing materials must be added to weights shown. Allow 15% additional weight for cartons, skids, crates, etc.
8. Add 4" in height for removable lifting lugs.
9. ZBTS(D) 600-1200A and ZBTSCT 100-1200A standard configuration is top entry. 14 rear adapter bay required for bottom entry. Consult GE Zenith
factory for details.
10. Bypass switch weights for 1600 - 4000 amp units vary up to 10% based on connections variations. Weights shown are for estimation only.
11. 3000 amp depth dimension shown is standard. Depending on your cable/conduit requirements you may desire a deeper enclosure. Consult the
GE Zenith factory for further details.
12. Lug adapters for 3000-4000 amp limits may be staggered length for ease of entrance. Consult the GE Zenith factory for details.

Reference Figures

C B
14" C B C B

Vent
See
A Note A
9 A

Vent

Figure D Figure E Figure F

Rev. 11/13 www.geindustrial.com BuyLog Catalog 14-27


Data subject to change
without notice
Automatic Transfer Switches Section 14
Critical Power Products
ZTS Series

ZTS Series Dimensional Specifications


Model ZTSCT Transfer Switches

NEMA 1 Enclosure Weight


Ampere Rating Poles Height (A) Width (B) Depth (C) Ref. Fig. Open Type NEMA 1 App. Notes
2, 3 74 (188) 40 (102) 19.5 (50) A 185 (84) 400 (181) 18
100, 150, 225, 260, 400, 600
4 74 (188) 40 (102 19.5 (50) A 205 (93) 450 (204) 18
2, 3 74 (188) 40 (102) 19.5 (50) A 210 (95) 475 (215) 18
800, 1000, 1200
4 74 (188) 40 (102) 19.5 (50) A 230 (104) 560 (254) 18
3 90 (229) 35.5 (90) 48 (122) B 365 (166) 1030 (467) 18
1600, 2000
4 90 (229) 35.5 (90) 48 (122) B 470 (204) 1190 (540) 18
3 90 (229) 35.5 (90) 48 (122) B 485 (220) 1150 (522) 1 10
3000
4 90 (229) 35.5 (90) 48 (122) B 690 (313) 1415 (642) 1 10
3 90 (229) 46.5 (118) 60 (152) B 820 (372) 1635 (742) 1 10
4000
4 90 (229) 46.5 (118) 60 (152) B 1045 (474) 1870 (848) 1 10

Application Notes:
1. Metric dimensions (cm) and weights (Kg) shown in parenthesis adjacent to English measurements in inches and pounds.
2. Includes 1.25" door projection beyond base depth. Allow a minimum of 3" additional depth for projection of handle, light, switches, pushbuttons, etc.
3. All dimensions and weights are approximate and subject to change without notice.
4. Special enclosures (NEMA 3R, 4, 4X, 12, etc.) dimensions and layout may differ. Consult the GE Zenith factory for details.
5. Normal and emergency may be ordered inverted on any switch. The load may be inverted 6001200 amps. Consult the factory for details.
6. Special lug arrangements may require different enclosure dimensions. For certified drawings, contact the GE Zenith factory.
7. Packing materials must be added to weights shown. Allow 15% additional weight for cartons, skids, crates, etc.
8. Add 4" in height for removable lifting lugs.
9. 4000 amp depth dimension shown is standard. Depending on your cable/conduit requirements you may desire a deeper enclosure. Consult the
GE Zenith factory for further details.
10. Lug adapters for 3000-4000 amp limits may be staggered length for ease of entrance. Consult the GE Zenith factory for details.

Reference Figures

Figure A Figure B

14-28 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Automatic Transfer Switches Section 14
Critical Power Products
Model ZTSMV

Model ZTSMV Medium Voltage Transfer Switches


The Standard of Quality in Design and Manufacturing

Introduction
ZTS Series Automatic Transfer Switches have been the preferred
standard for quality and reliability in the electrical industry. The
ZTSMV Model medium voltage automatic transfer switches pro-
vides that same quality for installations from 5kV to 15kV.
The ZTSMV Model is designed for use in the most critical applica-
tions: hospitals, military sites, airports, communications facilities,
and computer installations. ZTSMV Model switches fit the need for
dependable continuity of power where emergency or standby ap-
plications exist.
Backed by over 75 years of experience in manufacturing auto-
matic transfer switches, as well as extensive experience in the de-
sign and development of paralleling switchgear systems, the GE
ZTSMV Model provides the reliable answer to critical medium volt-
age switching applications. Like all GE switches, the ZTSMV Model
is supported by a nationwide network of field service facilities.

Construction
The switching elements consist of two vacuum circuit breakers in-
terlocked to ensure that only one set of contacts can be closed at
any one time. The control module for transferring operations of
the power unit is the same reliable microprocessor control system ZTSMV
that GE has designed, built and used on our low voltage auto-
matic transfer switches. The control module is physically isolated
from the power portion by an insulating barrier. The completed
unit is enclosed in a NEMA1 cabinet (NEMA 3R optional) and is
both front and rear accessible.

Model ZTSMV Medium Voltage Transfer Switches


Standard Features
The ZTSMV Features:
State-of-the-art vacuum breaker design
Electrically interlocked for secure operation
Over-current protection for the load
A drawout P.T. trunnion design on utility to facilitate removal
of control fuses from rear of cabinet
The control module completely isolated from power section
Standard indication of source availability
MX250 control with MSPES Options provided for use with
generator as an alternate source
A control circuit disconnect switch
Capable of supporting modules to allow remote communication
to annunciators, modems and SCADA systems
Drawout vacuum breaker design
Dual electrical interlocks
Compliance with ANSI/IEEE spec C37 and NEMA spec SG5
A drawout P.T. trunnion design on utility and generator side to
facilitate removal of control fuses while the system is operating
The control module completely isolated from power section
Standard indication of source availability
One year warranty

Rev. 11/13 www.geindustrial.com BuyLog Catalog 14-29


Data subject to change
without notice
Automatic Transfer Switches Section 14
Critical Power Products
Model ZTSMV

ZTSMV Series Medium Voltage Transfer Switches


Electrical Ratings
The ZTS-MV Series is available in a wide range of voltage, current and MVA classes. It is
critical to evaluate the project requirements prior to specifying the equipment. Verify:

Normal and emergency system voltages


Current rating requirements
MVA class
Short circuit rating
Protective relay requirements (if any)

ZTSMV
Rated Voltage 5kV 15kV 15kV
MVA Class 250 500 1,000
System Voltage 2.4 - 4.16 kV 7.2 - 13.8 kV 7.2 - 13.8 kV
Rated Current 1,200 A 1,200 - 3,000 A 1,200 - 3,000 A
Short Circuit Rating 29 kA @ 4.16 kV 20 kA @ 13.8 kV 40 kA @ 13.8 kV
33 kA @ 7.2 kV

NOTE: Additional ratings are available. Consult the factory for details.

Ordering Information

Z T S M V
Block A Block B Block C Block D Block E Block F Block G Block H Block I

Block A Block E Block F Block G


Model Designation System Voltage Rated Current MVA Rating
ZTSMV05 - 5kV Class V0 = 2400V, 3 phase, 3 wire 03 1,200A
ZTSMV15 - 15 kV Class V1 = 2400V, 3 phase, 4 wire 04 2,000A 02 250
Block B V2 = 4160V, 3 phase, 3 wire 05 3,000A 03 5001
Transition Type V3 = 4160V, 3 phase, 4 wire 05 10001
S - Standard Transition V4 = 6600V, 3 phase, 3 wire
D - Delayed Transition V5 = 6600V, 3 phase, 4 wire Block H Block I
T - Closed Transition V6 = 7200V, 3 phase, 3 wire Current Transformer Ratio on Utility Current Transformer Ratio on Emergency
Block C V7 = 7200V, 3 phase, 4 wire 01 100/5 09 800/5
NEMA W0 = 12.47kV, 3 phase, 3 wire 02 150/5 10 1000/5
C - NEMA 1 W1 = 12.47kV, 3 phase, 4 wire 03 200/5 11 1200/5
S - NEMA 3R V8 = 13.8kV, 3 phase, 3 wire 04 250/5 12 1500/5 Use same chart as Block H
Block D V9 = 13.8kV, 3 phase, 4 wire 05 300/5 13 1600/5
Number of Poles VX = Special Voltage 06 400/5 14 2000/5
3 07 500/5 15 2500/5
08 600/5 16 3000/5
1115kV Class (7.2-15 kV only)

*Other ratings are available. Contact the factory for details.

14-30 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Automatic Transfer Switches Section 14
Critical Power Products
Model ZTSMV

Standard Accessories Optional Accessories


MSPES Option Group Protective Relays
A1 Auxiliary Contact Energized on Normal (SPDT) UPR1-A Utility Source 1
A1E Auxiliary Contact Energized on Emergency (SPDT) Protective Relay (GE SR750)
A3 Auxiliary Contact Closed in Emergency Position UPR1-B Utility Source 1
A4 Auxiliary Contact Closed in Normal Position Protective Relay (GE F60)
A6 Timed Load Disconnect Prior to Transfer (Adjustable) UPR2-A Utility Source 2
C/D Load/No-load exerciser clock (specify 7, 14 or 365 day) 2 Protective Relays (GE SR750)
E Engine Start Contact UPR2-B Utility Source 2
J2E Over/Under Frequency Normal Source 2 Protective Relays (GE F60)
J2N Over/Under Frequency Emergency Source GRP2-A Generator Source 3
L1 Pilot Light Transfer Switch in Normal Position 2 Protective Relays (GE SR489)
L2 Pilot Light Transfer Switch in Emergency Position IPR1-C Source 1 Industrial Grade
L3 Pilot Light Emergency Power Available Protective Relay (MX3500)
L4 Pilot Light Normal Power Available IPR2-C Source 2 Industrial Grade
P1 Time Delay Engine Start (Adjustable) Protective Relay (MX3500)
Q2 Peak Shave/Remote Load Test: Input for peak shave
or remote load test; includes automatic return to Other Accessories Available Include:
normal if emergency source fails and normal is Multi-function power measurement metering including amps,
present; 120 VAC or 24 VDC volts, frequency, KW, KVA, KVAR, etc.
Q3 Inhibit Transfer: Input circuit to inhibit transfer to Soft load switches are available. Consult the factory.
emergency; 120 VAC or 24 VDC
R1 Over Voltage Normal Source
R8 Over Voltage Emergency Source
R16 Phase Sequence Sensing
R17 Under-voltage Sensing: Emergency (3 phase)
R50 In-phase monitor (if delayed transition units are not
specified)
T Time Delay Retransfer to Normal (Adjustable)
U Time Delay Engine Cooldown (Adjustable)
W Time Delay Transfer to Emergency (Adjustable)
YEN Time Delay Bypass Switch (T & W Timers)

Rev. 11/13 www.geindustrial.com BuyLog Catalog 14-31


Data subject to change
without notice
Automatic Transfer Switches Section 14
Critical Power Products
Model ZTE

ZTE Series
Low-Voltage, Open Transition, Automatic and Manual Transfer
Switches
Ideal for mixed (inductive and resistive) mission critical loads
Contact transfer speed less than 100 milliseconds
Double throw, interlocked operation
Ratings 40 to 4000 amperes Control Group Options (see order code)
Group A: All standard features, Field re-programmable I/O (4 in-
Ratings & Construction puts, 4 outputs), Control Switches (Test with Load, Test no load,
Ratings Voltage, Ampere and Pole configuration per Fast Test, Alarm Reset, Auto/Man Re-transfer Source 1,
Order Code Auto/Man Transfer both sources, Preferred Source select,
Certifications UL 1008, CSA C22.2 Commit/No Commit Transfer to Gen, Time Delay Bypass
Certifications Third-party Seismic Certification to IBC 2009, Group B: All features from A plus: 10 User-configurable Analog
3.2g @ Ip = 1.5 (operation during event) & 10 Digital Alarms, 20-channel data logger, 10-channel wave-
Electrical Operator Momentarily energized, high-speed form capture, Auto Load Shed (with voltage, frequency, and
solenoid mechanism kW triggers)
Mechanism Mechanically-held with mechanical interlock to Group C: All features from B plus: 4 additional field program-
inhibit connection of both sources to the load mable inputs (total 8 inputs, 8 outputs)
Contacts GE design and manufactured, silver tungsten alloy Group D: All features from C plus: 4 additional field program-
with separate arcing contacts on 600A and above ratings for mable inputs (total 12 inputs, 12 outputs) & GE Flexlogic user-
high withstand and close-on capability configurable control logic
Neutral Pole (4 pole only) Identical construction to phase Group M: Manual ATS configuration
poles with fully rated main and arcing contacts. Operation via
same mechanism as phase poles to prevent sustained connec- Additional Standard Features
tion of source neutrals in separately derived systems, as last- Engine Exerciser Configurable Periodic Exerciser (7 Event
break/first-make transfer. Daily, Weekly, 14 or 28 day) or Clock Exerciser Type (21 Event,
365 day Programmable)
Controller System Status Screen Active state of switch, display of all time
Construction Dual-processor based, with dedicated processor delays and alarm conditions
for high-speed Serial or Ethernet communications Event Recorder 256 Event, 1ms accuracy, clock sync via
Source Sensing Direct 120-690V sensing and software config- Network Time Protocol (NTP)
uration of rated voltage and frequency without the need for Outage & Test Report Screen Date/time stamping of: outage or
potential transformers, step-down transformers or DIP switches test event, start signal sent, Gen start time, connection to Gen,
Control Wiring All customer connections at one location. All Max Gen Volts & Freq dip, return of utility, re-transfer to normal
signals in/out relay-isolated via DIN-mounted relay/terminal External Power Supply Standard 120VAC input for controller
blocks. All control wiring via factory-installed wiring harnesses power and communication and 24 VDC input for remote control
Enclosure and annunciation when both sources de-energized
Flexible Feature Assignment Field reassignable I/O for any/all
Type per Order Code
control features
Display, Sensing & Time Delays In-Phase Monitor For phase matching prior to Live-Live
Display VGA color graphical with embedded HELP menus transfers of load
Annunciation High intensity LED for Source Availability (2), Optional Features (see order code)
Source Connected (2), Transfer Inhibit (not in Auto)
Serial Communications High speed, up to 115k Baud
Source Fail/Restore Independently adjustable pickup &
Modbus RTU
dropout of 3-phase U/O voltage, U/O Freq, Volts Balance plus
Ethernet Communications Fast Ethernet, (10/100 Mbit),
Phase Rotation
Modbus TCP/IP
Time Delays Gen start, Source 2 stabilize, Source 2 fail
Power Quality Metering True RMS metering, including THD%
override, Retransfer to Source 1, Gen cool down, Independent
(up to 8th order)
settings for Fast Test, Time Delay for Generator Voltage Sag
Load Shed Ability to transfer to de-energized normal source or
Remote Access All parameters locally (front USB port) or
center position in event of generator overload
remotely (serial or Ethernet) Adjustable
Integral Surge Protective Device (SPD) Load-connected
medium or high exposure type
Integral Battery Charger 3 or 10A, 12 or 24VDC type
Lugs Compression lugs in lieu of standard mechanical lugs on
100A-1200A switches
Lugs Mechanical or Compression lugs in lieu of standard rear-
bus connection on 1600-4000A switches

14-32 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Automatic Transfer Switches Section 14
Critical Power Products
Model ZTE

Order Code Abbreviated Product Configuration


(see full Product Brochure, Publication DEA-405, for full configuration)

Z10 X
Amperage Ground Bus SPD Battery
A = 40 # of Poles NEMA Enclosure Voltage Code Metering & Accessories X = None (Load-Side Connected) Charger
B = 80 2 = 2 Pole X = None (Open) 70 = 277/480V, 3PH, 4W, 60Hz X = None 1 = Ground bus- 100A - 1200A Rating X = None
C = 100 3 = 3 Pole A = NEMA 1 20 = 120/240V, 1PH, 3W, 60Hz A = Load Shed X = None
D = PQ Metering Mech Lugs 1 = Battery
D = 150 4 = 4 Pole B = NEMA 1A 40 = 120/208V, 3PH, 4W, 60Hz (Qty. 3) #14-1/0-GB1 A = 65kA Charger-12
F = 225 C = NEMA 3R 92 = 220/380V, 3PH, 4W, 50Hz (see full product B = 80kA
2 = Ground bus- Volt-3 Amp
brochure for
G = 260 D = NEMA 3R w/Htr 50 = 480V, 3PH, 3W, 60Hz Mech Lugs C = 100kA
other options) 2 = Battery
I = 400 E = NEMA 4 38 = 120/208/240V, 3PH, 4W, (Qty. 6) #8-1/0 -GB2 1600A - 4000A Rating
Application F = NEMA 12 Charger-12
J = 600 High-Leg Delta, 60Hz X = None
(see full product Volt-10 Amp
K = 800 S = Util-Gen G = NEMA 4X 30 = 240V, 3PH, 3W, 60Hz D = 100kA
brochure for
L = 1000 U = Util-Util 31 = 208V, 3PH, 3W, 60Hz E = 150kA (see full product
other options)
M = 1200 G = Gen-Gen 61 = 347/600V, 3PH, 4W, 60Hz F = 200kA brochure for
N = 1600 G = 300kA other options)
(see full product brochure
O = 2000 for other options (see full product
Q = 3000 Control
brochure for
R = 4000 Group Options
other options)
Controller Language A = Group A Lug Options Communications
1 = English B = Group B X = Std lugs or Rear bus X = None
C = Group C (per chart below) S = CCM S-Modbus RTU (Serial) communication module
D = Group D
(see full product brochure E = CCM E Modbus TCP/IP (Ethernet) communication module
M = Group M
for lug option details) E = plus Modbus RTU (Serial) communication module

ZTE Model, Dimensions and Weights AL-CU UL Listed Mechanical Lugs


NEMA 1 Weight Application Normal, Emergency & Load Terminals
Ampere Rating Poles Height (A) Width (B) Depth (C) Ref. Figure Open Type NEMA 1 Notes Switch Size Amps Cables/Pole Wire Ranges
*100, 150, 225 3 125 (57) 220 (100) ZTE
66 (168) 24 (61) 20 (50) B 1-7
260, 400 4 146 (66) 241 (109) 40, 80 1 #8 to 3/0
40, 80, 100 2, 3 14 (7) 120 (55) 100, 150 1 #6 to 250 MCM
46 (117) 24 (61) 14 (36) A 1-6
150, 225 4 20 (9) 126 (57) 225 1 #4 to 600 MCM
2, 3 59 (27) 168 (76) 260 1 #4 to 600 MCM
260, 400 46 (117) 24 (61) 14 (36) A 1-6
4 70 (32) 180 (82) 400 1 #4 to 600 MCM
2, 3 150 (68) 410 (186) 600 2 #2 to 600 MCM
600 74 (188) 40 (102) 19.5 (50) B 1-7
4 180 (82) 440 (200) 800, 1000, 1200 4 #2 to 600 MCM
2, 3 190 (86) 460 (209) 1600, 2000, 3000, 4000 * *
800, 1000, 1200 74 (188) 40 (102) 19.5 (50) B 1-7
4 230 (104) 490 (222)
3 345 (156) 1010 (458) Notes:
1600, 2000 90 (229) 35.5 (90) 48 (122) C 1-9
4 450 (204) 1160 (526) * Line and load terminals are located in rear and
3 465 (211) 1130 (513) arranged for bus bar connection. Terminal lugs are
3000 90 (229) 35.5 (90) 48 (122) C 19
4 670 (304) 1396 (633) available as an accessory. See full product brochure
3 770 (349) 1595 (723)
4000 90 (229) 46.5 (118) 60 (152) C 1-9 (DEA-405) for option details.
4 1025 (465) 1850 (839)
1. Fully rated neutral provided on 3 phase, 4 wire system
* For ZTECT models only

Application Notes
1. Metric dimensions (cm) and weights (Kg) shown in parenthesis
adjacent to English measurements in inches and pounds.
2. Includes 1.25" door projection beyond base depth. Allow a minimum
of 3" additional depth for projection of handle, light, switches,
pushbuttons, etc.
3. All dimensions and weights are subject to change without notice.
4. NEMA 3R, 4, 4X and 12 enclosure dimensions may differ than NEMA
1 shown above. Consult the factory for details.
5. Special lug arrangements may require different enclosure
dimensions. See full product brochure (DEA-405) for details.
6. Packing materials must be added to weights shown. Allow 15%
additional weight for cartons, skids, crates, etc.
7. Add 4" in height for removable lifting lugs.
8. Lug adapters for 3000-4000A limits may be staggered length for
ease of entrance. Consult the factory for details.
9. 1600-4000A switches have ventilation louvers on both sides and
rear of enclosure. Louvers must be clear for airflow with standard
cable connections.

Rev. 11/13 www.geindustrial.com BuyLog Catalog 14-33


Data subject to change
without notice
Automatic Transfer Switches Section 14
Critical Power Products
Model ZTED

ZTED Series
Low-Voltage, Delayed Transition, Automatic and Manual
Transfer Switches
Ideal for inductive (motors/transformers, UPS) mission
critical loads
Control Group Options (see order code)
Adjustable, time delay in centered off position
Mechanically interlocked center-off position for load decay Group A: All standard features, Field re-programmable I/O
Ratings 40 to 4000 amperes (4 inputs, 4 outputs), Control Switches (Test with Load, Test no
load, Fast Test, Alarm Reset, Auto/Man Re-transfer Source 1,
Ratings & Construction Auto/Man Transfer both sources, Preferred Source select,
Ratings Voltage, Ampere and Pole configuration per Commit/No Commit Transfer to Gen, Time Delay Bypass
Order Code Group B: All features from A plus: 10 User-configurable Analog
Certifications UL 1008, CSA C22.2 & 10 Digital Alarms, 20-channel data logger, 10-channel wave-
Certifications Third-party Seismic Certification to IBC 2009, form capture, Auto Load Shed (with voltage, frequency, and
3.2g @ Ip = 1.5 (operation during event) kW triggers)
Electrical Operator Momentarily energized, high-speed Group C: All features from B plus: 4 additional programmable
solenoid mechanism inputs (total 8 inputs, 8 outputs)
Mechanism Mechanically-held with mechanical interlock to Group D: All features from C plus: 4 additional field program-
inhibit connection of both sources to the load mable inputs (total 12 inputs, 12 outputs) & GE Flexlogic
Contacts GE design and manufactured, silver tungsten alloy user-configurable control logic
with separate arcing contacts on 600A and above ratings for Group M: Manual ATS configuration
high withstand and close-on capability
Additional Standard Features
Neutral Pole (4 pole only) Identical construction to phase
poles with fully rated main and arcing contacts. Operation via Engine Exerciser Configurable Periodic Exerciser (7 Event
same mechanism as phase poles to prevent sustained connec- Daily, Weekly, 14 or 28 day) or Clock Exerciser Type (21 Event,
tion of source neutrals in separately derived systems, as last- 365 day Programmable)
break/ first-make transfer. System Status Screen Active state of switch, display of all time
delays and alarm conditions
Controller Event Recorder 256 Event, 1ms accuracy, clock sync via
Construction Dual-processor based, with dedicated processor Network Time Protocol (NTP)
for high-speed Serial or Ethernet communications Outage & Test Report Screen Date/time stamping of: outage
Source Sensing Direct 120-690V sensing and software config- or test event, start signal sent, Gen start time, connection to
uration of rated voltage and frequency without the need for Gen, Max Gen Volts & Freq dip, return of utility, re-transfer
potential transformers, step-down transformers or DIP switches to normal
Control Wiring All customer connections at one location. All External Power Supply Standard 120VAC input for controller
signals in/out relay-isolated via DIN-mounted relay/terminal power and communication and 24 VDC input for remote control
blocks. All control wiring via factory-installed wiring harnesses. and annunciation when both sources de-energized
Enclosure Flexible Feature Assignment Field reassignable I/O for any/all
control features
Type per Order Code
Programmable Center-Off Position For transition of motor
Display, Sensing & Time Delays and regenerative loads
Display VGA color graphical with embedded HELP menus Optional Features (see order code)
Annunciation High intensity LED for Source Availability (2),
Serial Communications High speed, up to 115k Baud
Source Connected (2), Transfer Inhibit (not in Auto)
Modbus RTU
Source Fail/Restore Independently adjustable pickup &
Ethernet Communications Fast Ethernet, (10/100 Mbit),
dropout of 3-phase U/O voltage, U/O Freq, Volts Balance plus
Modbus TCP/IP
Phase Rotation
Time Delays Gen start, Source 2 stabilize, S1 g S2 transfer
Power Quality Metering True RMS metering, including THD%
(up to 8th order)
center-off delay, Source 2 fail override, Retransfer to Source 1,
S2 g S1 transfer center-off delay, Gen cool down, Independent
Load Shed Ability to transfer to de-energized normal source or
center position in event of generator overload
settings for Fast Test, Time Delay for Generator Voltage Sag
Integral Surge Protective Device (SPD) Load-connected
Remote Access All parameters locally (front USB port) or
medium or high exposure type
remotely (serial or Ethernet) Adjustable
Integral Battery Charger 3 or 10A, 12 or 24VDC type
Lugs Compression lugs in lieu of standard mechanical lugs on
100A-1200A switches
Lugs Mechanical or Compression lugs in lieu of
standard rear-bus

14-34 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Automatic Transfer Switches Section 14
Critical Power Products
Model ZTED

Order Code Abbreviated Product Configuration


(see full Product Brochure, Publication DEA-405, for full configuration)

Z1D X
Amperage Ground Bus SPD Battery
A = 40 # of Poles NEMA Enclosure Voltage Code Metering & Accessories X = None (Load-Side Connected) Charger
B = 80 2 = 2 Pole X = None (Open) 70 = 277/480V, 3PH, 4W, 60Hz X = None 1 = Ground bus- 100A - 1200A Rating X = None
C = 100 3 = 3 Pole A = NEMA 1 20 = 120/240V, 1PH, 3W, 60Hz A = Load Shed X = None
D = PQ Metering Mech Lugs 1 = Battery
D = 150 4 = 4 Pole B = NEMA 1A 40 = 120/208V, 3PH, 4W, 60Hz (Qty. 3) #14-1/0-GB1 A = 65kA Charger-12
F = 225 C = NEMA 3R 92 = 220/380V, 3PH, 4W, 50Hz (see full product B = 80kA
2 = Ground bus- Volt-3 Amp
brochure for
G = 260 D = NEMA 3R w/Htr 50 = 480V, 3PH, 3W, 60Hz Mech Lugs C = 100kA
other options) 2 = Battery
I = 400 E = NEMA 4 38 = 120/208/240V, 3PH, 4W, (Qty. 6) #8-1/0 -GB2 1600A - 4000A Rating
Application F = NEMA 12 Charger-12
J = 600 High-Leg Delta, 60Hz X = None
(see full product Volt-10 Amp
K = 800 S = Util-Gen G = NEMA 4X 30 = 240V, 3PH, 3W, 60Hz D = 100kA
brochure for
L = 1000 U = Util-Util 31 = 208V, 3PH, 3W, 60Hz E = 150kA (see full product
other options)
M = 1200 G = Gen-Gen 61 = 347/600V, 3PH, 4W, 60Hz F = 200kA brochure for
N = 1600 G = 300kA other options)
(see full product brochure
O = 2000 for other options (see full product
Q = 3000 Control
brochure for
R = 4000 Group Options
other options)
Controller Language A = Group A Lug Options Communications
1 = English B = Group B X = Std lugs or Rear bus X = None
C = Group C (per chart below) S = CCM S-Modbus RTU (Serial) communication module
D = Group D
(see full product brochure E = CCM E Modbus TCP/IP (Ethernet) communication module
M = Group M
for lug option details) E = plus Modbus RTU (Serial) communication module

ZTED Model, Dimensions and Weights AL-CU UL Listed Mechanical Lugs


NEMA 1 Weight Application Normal, Emergency & Load Terminals
Ampere Rating Poles Height (A) Width (B) Depth (C) Ref. Figure Open Type NEMA 1 Notes
Switch Size Amps Cables/Pole Wire Ranges
40, 80, 100 2, 3 80 (36) 120 (59) ZTED
150, 225 4 46 24 14 85 (39) 126 (57)
A 1-6 40, 80 1 #8 to 3/0
2, 3 (1168) (610) (356) 80 (36) 168 (76)
260, 400 100, 150, 225 1 #4 to 600 MCM
4 85 (39) 180 (82)
2, 3 185 (84) 410 (186) 260 1 #4 to 600 MCM
600 400 1 #4 to 600 MCM
4 74 40 19.8 205 (93) 440 (200)
2, 3 (1880) (1016) (502) 210 (95) 460 (209) 600 2 #2 to 600 MCM
800 B 1-7 800, 1000, 1200 4 #2 to 600 MCM
4 230 (104) 490 (223)
2, 3 74 40 19.5 210 (95) 460 (209) 1600, 2000, 3000, 4000 * *
1000, 1200
4 (1880) (1016) (495) 230 (104) 490 (223) Notes:
3 365 (166) 1010 (458)
1600, 2000 1-7, 9 * Line and load terminals are located in rear and
4 90 35.5 47.9 470 (204) 1160 (526)
3 (2286) (902) (1216) 485 (220) 1130 (513)
arranged for bus bar connection. Terminal lugs are
3000 C available as an accessory. See full product brochure
4 690 (313) 1396 (633)
1-9 (DEA-405) for option details.
3 90 46.5 60 820 (372) 1595 (723)
4000
4 (2286) (1180) (1524) 1045 (474) 1850 (839) 1. Fully rated neutral provided on 3 phase, 4 wire system

Application Notes
1. Metric dimensions (cm) and weights (Kg) shown in parenthesis adjacent to English
measurements in inches and pounds.
2. Includes 1.25" door projection beyond base depth. Allow a minimum of 3"
additional depth for projection of handle, light, switches, pushbuttons, etc.
3. All dimensions and weights are subject to change without notice.
4. NEMA 3R, 4, 4X and 12 enclosure dimensions may differ than NEMA 1 shown
above. Consult the factory for details.
5. Special lug arrangements may require different enclosure dimensions. See full
product brochure (DEA-405) for details.
6. Packing materials must be added to weights shown. Allow 15% additional weight
for cartons, skids, crates, etc.
7. Add 4" in height for removable lifting lugs.
8. Lug adapters for 3000-4000A limits may be staggered length for ease of entrance.
Consult the factory for details.
9. 1600-4000A switches have ventilation louvers on both sides and rear of enclosure.
Louvers must be clear for airflow with standard cable connections.

UL 1008 Withstand and Closing Ratings


Please refer to GE Publication TB-1102

Rev. 11/13 www.geindustrial.com BuyLog Catalog 14-35


Data subject to change
without notice
Automatic Transfer Switches Section 14
Critical Power Products
Model ZTECT

ZTECT Series
Low-Voltage, Closed Transition, Automatic and Manual
Transfer Switches
Ideal for mission critical loads (computer servers, HID
emergency lighting, data acquisition equipment)
Two source parallel time (bumpless transfer) of less than
Control Group Options (see order code)
100 milliseconds
Integrated backup protection to prevent extended Group A: All standard features, Field re-programmable I/O
parallel conditions (4 inputs, 4 outputs), Control Switches (Test with Load, Test no
Ratings 100 to 4000 amperes load, Fast Test, Alarm Reset, Auto/Man Re-transfer Source 1,
Auto/Man Transfer both sources, Preferred Source select,
Ratings & Construction Commit/No Commit Transfer to Gen, Time Delay Bypass
Ratings Voltage, Ampere and Pole configuration per Group B: All features from A plus: 10 User-configurable Analog
Order Code & 10 Digital Alarms, 20-channel data logger, 10-channel
Certifications UL 1008, CSA C22.2 waveform capture, Auto Load Shed (with voltage, frequency,
Certifications Third-party Seismic Certification to IBC 2009, and kW triggers)
3.2g @ Ip = 1.5 (operation during event) Group C: All features from B plus: 4 additional field
Electrical Operator Momentarily energized, high-speed programmable inputs (total 8 inputs, 8 outputs)
solenoid mechanism Group D: All features from C plus: 4 additional field
Mechanism Mechanically-held with highspeed transfer programmable inputs (total 12 inputs, 12 outputs) & GE Flexlogic
mechanism for make-beforebreak closed transition transfers user-configurable control logic
Contacts GE design and manufactured, silver tungsten alloy Group M: Manual ATS configuration
with separate arcing contacts on 600A and above ratings for
Additional Standard Features
high withstand and close-on capability
Neutral Pole (4 pole only) Identical construction to phase Engine Exerciser Configurable Periodic Exerciser (7 Event
poles with fully rated main and arcing contacts. Operation via Daily, Weekly, 14 or 28 day) or Clock Exerciser Type (21 Event,
same mechanism as phase poles to prevent sustained 365 day Programmable)
connection of source neutrals in separately derived systems, as System Status Screen Active state of switch, display of all
last-break/ first-make transfer. time delays and alarm conditions
Event Recorder 256 Event, 1ms accuracy, clock sync via
Controller Network Time Protocol (NTP)
Construction Dual-processor based, with dedicated processor Outage & Test Report Screen Date/time stamping of: outage
for high-speed Serial or Ethernet communications or test event, start signal sent, Gen start time, connection to Gen,
Source Sensing Direct 120-690V sensing and software Max Gen Volts & Freq dip, return of utility, re-transfer to normal
configuration of rated voltage and frequency without the External Power Supply Standard 120VAC input for controller
need for potential transformers, step-down transformers or power and communication and 24 VDC input for remote control
DIP switches and annunciation when both sources de-energized
Control Wiring All customer connections at one location. All Flexible Feature Assignment Field reassignable I/O for any/all
signals in/out relay-isolated via DIN-mounted relay/terminal control features
blocks. All control wiring via factory-installed wiring harnesses. Fail to Sync and Extended Parallel Protection Hardwired,
Enclosure independent controller
Type per Order Code Optional Features (see order code)
Display, Sensing & Time Delays Serial Communications High speed, up to 115k Baud
Modbus RTU
Display VGA color graphical with embedded HELP menus Ethernet Communications Fast Ethernet, (10/100 Mbit),
Annunciation High intensity LED for Source Availability (2), Modbus TCP/IP
Source Connected (2), Transfer Inhibit (not in Auto) Power Quality Metering True RMS metering, including THD%
Source Fail/Restore Independently adjustable pickup & (up to 8th order)
dropout of 3-phase U/O voltage, U/O Freq, Volts Balance plus Load Shed Ability to transfer to de-energized normal source
Phase Rotation or center position in event of generator overload
Time Delays Gen start, Source 2 stabilize, Source 2 fail Integral Surge Protective Device (SPD) Load-connected
override, Retransfer to Source 1, Gen cool down, Independent medium or high exposure type
settings for Fast Test, Time Delay for Generator Voltage Sag Integral Battery Charger 3 or 10A, 12 or 24VDC type
Remote Access All parameters locally (front USB port) or Lugs Compression lugs in lieu of standard mechanical lugs on
remotely (serial or Ethernet) Adjustable 100A-1200A switches
Lugs Mechanical or Compression lugs in lieu of standard rear-
bus connection on 1600-4000A switches

14-36 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Automatic Transfer Switches Section 14
Critical Power Products
Model ZTECT

Order Code Abbreviated Product Configuration


(see full Product Brochure, Publication DEA-405, for full configuration)

Z1C X
Amperage Ground Bus SPD Battery
C = 100 # of Poles NEMA Enclosure Voltage Code Metering & Accessories X = None (Load-Side Connected) Charger
D = 150 2 = 2 Pole X = None (Open) 70 = 277/480V, 3PH, 4W, 60Hz X = None 1 = Ground bus- 100A - 1200A Rating X = None
F = 225 3 = 3 Pole A = NEMA 1 20 = 120/240V, 1PH, 3W, 60Hz A = Load Shed X = None
D = PQ Metering Mech Lugs 1 = Battery
G = 260 4 = 4 Pole B = NEMA 1A 40 = 120/208V, 3PH, 4W, 60Hz (Qty. 3) #14-1/0-GB1 A = 65kA Charger-12
I = 400 C = NEMA 3R 92 = 220/380V, 3PH, 4W, 50Hz (see full product B = 80kA
2 = Ground bus- Volt-3 Amp
brochure for
J = 600 D = NEMA 3R w/Htr 50 = 480V, 3PH, 3W, 60Hz Mech Lugs C = 100kA
other options) 2 = Battery
K = 800 E = NEMA 4 38 = 120/208/240V, 3PH, 4W, (Qty. 6) #8-1/0 -GB2 1600A - 4000A Rating
Application F = NEMA 12 Charger-12
L = 1000 High-Leg Delta, 60Hz X = None
(see full product Volt-10 Amp
M = 1200 S = Util-Gen G = NEMA 4X 30 = 240V, 3PH, 3W, 60Hz D = 100kA
brochure for
N = 1600 U = Util-Util 31 = 208V, 3PH, 3W, 60Hz E = 150kA (see full product
other options)
O = 2000 G = Gen-Gen F = 200kA brochure for
(see full product brochure
Q = 3000 G = 300kA other options)
for other options
R = 4000 (see full product
Control
brochure for
Group Options
other options)
Controller Language A = Group A Lug Options Communications
1 = English B = Group B X = Std lugs or Rear bus X = None
C = Group C (per chart below) S = CCM S-Modbus RTU (Serial) communication module
D = Group D
(see full product brochure E = CCM E Modbus TCP/IP (Ethernet) communication module
M = Group M
for lug option details) E = plus Modbus RTU (Serial) communication module

ZTECT Model, Dimensions and Weights AL-CU UL Listed Mechanical Lugs


NEMA 1 Weight Application Normal, Emergency & Load Terminals
Ampere Rating Poles Height (A) Width (B) Depth (C) Ref. Figure Open Type NEMA 1 Notes
Switch Size Amps Cables/Pole Wire Ranges
100, 150, 225 3 125 (57) 220 (100) ZTECT
66 (168) 24 (61) 20 (50) A
260, 400 4 146 (66) 241 (109)
120 (59) 100, 150 1 #4 to 600 MCM
185 (84) 225 1 #4 to 600 MCM
2, 3 126 (57) 260 1 #4 to 600 MCM
600 400 1 #4 to 600 MCM
74 40 19.8 168 (76) 600 2 #2 to 600 MCM
A 1-7
4 (1880) (1016) (502) 205 (93) 800, 1000, 1200 4 #2 to 600 MCM
180 (82) 1600, 2000, 3000, 4000 * *
800, 1000 2, 3 210 (95) 460 (209) Notes:
1200 4 230 (104) 490 (223)
* Line and load terminals are located in rear and
3 365 (166) 1010 (458)
1600, 2000 arranged for bus bar connection. Terminal lugs are
4 90 35.5 47.9 470 (204) 1160 (526)
3 (2286) (902) (1216) 485 (220) 1130 (513) available as an accessory. See full product brochure
3000 B (DEA-405) for option details.
4 690 (313) 1396 (633)
1-9
3 90 46.5 60 820 (372) 1595 (723) 1. Fully rated neutral provided on 3 phase, 4 wire system
4000
4 (2286) (1180) (1524) 1045 (474) 1850 (839)

Application Notes
1. Metric dimensions (cm) and weights (Kg) shown in parenthesis adjacent to English
measurements in inches and pounds.
2. Includes 1.25" door projection beyond base depth. Allow a minimum of 3" addi-
tional depth for projection of handle, light, switches, pushbuttons, etc.
3. All dimensions and weights are subject to change without notice.
4. NEMA 3R, 4, 4X and 12 enclosure dimensions may differ than NEMA 1 shown
above. Consult the factory for details.
5. Special lug arrangements may require different enclosure dimensions. See full
product brochure (DEA-405) for details.
6. Packing materials must be added to weights shown. Allow 15% additional weight
for cartons, skids, crates, etc.
7. Add 4" in height for removable lifting lugs.
8. 3000-4000A depth dimension shown is standard. Depending on your cable/con-
duit requirements, you may desire a deeper enclosure. Consult the factory for
further details.
9. 1600-4000A switches have ventilation louvers on both sides and rear of enclosure.
Louvers must be clear for airflow with standard cable connections.

UL 1008 Withstand and Closing Ratings


Please refer to GE Publication TB-1102

Rev. 11/13 www.geindustrial.com BuyLog Catalog 14-37


Data subject to change
without notice
Automatic Transfer Switches Section 14
Critical Power Products
Model ZBTE

ZBTE Series
Low-Voltage, Bypass/Isolation Open Transition, Automatic and
Manual Transfer Switches
Ideal for mixed (inductive and resistive) mission critical loads
Contact transfer speed less than 100 milliseconds
Control Group Options (see order code)
Bypass/Isolation for ease of ATS maintenance/testing without
load loss of power Group A: All standard features, Field re-programmable I/O (4
Ratings 100 to 4000 amperes inputs, 4 outputs), Control Switches (Test with Load, Test no
load, Fast Test, Alarm Reset, Auto/Man Re-transfer Source 1,
Ratings & Construction Auto/Man Transfer both sources, Preferred Source select,
Ratings Voltage, Ampere and Pole configuration per Commit/No Commit Transfer to Gen, Time Delay Bypass
Order Code Group B: All features from A plus: 10 User-configurable Analog
Certifications UL 1008, CSA C22.2 & 10 Digital Alarms, 20-channel data logger, 10-channel
Certifications Third-party Seismic Certification to IBC 2009, waveform capture, Auto Load Shed (with voltage, frequency,
3.2g @ Ip = 1.5 (operation during event) and kW triggers)
Electrical Operator Momentarily energized, high-speed Group C: All features from B plus: 4 additional field
solenoid mechanism programmable inputs (total 8 inputs, 8 outputs)
Mechanism Mechanically-held with mechanical interlock to Group D: All features from C plus: 4 additional field
inhibit connection of both sources to the load programmable inputs (total 12 inputs, 12 outputs) & GE Flexlogic
Contacts GE design and manufactured, silver tungsten alloy user-configurable control logic
with separate arcing contacts on 600A and above ratings for Group M: Manual ATS configuration
high withstand and close-on capability
Additional Standard Features
Neutral Pole (4 pole only) Identical construction to phase
poles with fully rated main and arcing contacts. Operation via Engine Exerciser Configurable Periodic Exerciser (7 Event
same mechanism as phase poles to prevent sustained Daily, Weekly, 14 or 28 day) or Clock Exerciser Type (21 Event,
connection of source neutrals in separately derived systems, as 365 day Programmable)
last-break/first-make transfer. System Status Screen Active state of switch, display of all time
delays and alarm conditions
Controller Event Recorder 256 Event, 1ms accuracy, clock sync via
Construction Dual-processor based, with dedicated processor Network Time Protocol (NTP)
for high-speed Serial or Ethernet communications Outage & Test Report Screen Date/time stamping of: outage
Source Sensing Direct 120-690V sensing and software or test event, start signal sent, Gen start time, connection to
configuration of rated voltage and frequency without the need Gen, Max Gen Volts & Freq dip, return of utility, re-transfer
for potential transformers, step-down transformers or to normal
DIP switches External Power Supply Standard 120VAC input for controller
Control Wiring All customer connections at one location. All power and communication and 24 VDC input for remote control
signals in/out relay-isolated via DIN-mounted relay/terminal and annunciation when both sources de-energized
blocks. All control wiring via factory-installed wiring harnesses. Flexible Feature Assignment Field reassignable I/O for any/all
Enclosure control features
In-Phase Monitor For phase matching prior to Live-Live
Type per Order Code
transfers of load
Display, Sensing & Time Delays
Optional Features (see order code)
Display VGA color graphical with embedded HELP menus
Serial Communications High speed, up to 115k Baud
Annunciation High intensity LED for Source Availability (2),
Modbus RTU
Source Connected (2), Transfer Inhibit (not in Auto)
Ethernet Communications Fast Ethernet, (10/100 Mbit),
Source Fail/Restore Independently adjustable pickup &
Modbus TCP/IP
dropout of 3-phase U/O voltage, U/O Freq, Volts Balance plus
Power Quality Metering True RMS metering, including THD%
Phase Rotation
(up to 8th order)
Time Delays Gen start, Source 2 stabilize, Source 2 fail
Load Shed Ability to transfer to de-energized normal source or
override, Retransfer to Source 1, Gen cool down, Independent
center position in event of generator overload
settings for Fast Test, Time Delay for Generator Voltage Sag
Integral Surge Protective Device (SPD) Load-connected
Remote Access All parameters locally (front USB port) or
medium or high exposure type
remotely (serial or Ethernet) Adjustable
Integral Battery Charger 3 or 10A, 12 or 24VDC type
Lugs Compression lugs in lieu of standard mechanical lugs on
100A-1200A switches
Lugs Mechanical or Compression lugs in lieu of standard rear-
bus connection on 1600-4000A switches

14-38 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Automatic Transfer Switches Section 14
Critical Power Products
Model ZBTE

Order Code Abbreviated Product Configuration


(see full Product Brochure, Publication DEA-405, for full configuration)

Z O X
Ground Bus SPD Battery
Product Type Operation Amperage # of Poles NEMA Enclosure Voltage Code Metering & X = None (Load-Side Connected) Charger
Z2*** = Bypass/ O = Open C = 100 2 = 2 Pole X = None (Open) 70 = 277/480V, 3PH, 4W, 60Hz Accessories
1 = Ground bus- 100A - 1200A Rating X = None
X = None
Isolation Vertical Transition D = 150 3 = 3 Pole H = NEMA 1 20 = 120/240V, 1PH, 3W, 60Hz A = Load Shed Mech Lugs X = None 1 = Battery
Construction F = 225 4 = 4 Pole w/Adapter Bay 40 = 120/208V, 3PH, 4W, 60Hz D = PQ Metering (Qty. 3) A = 65kA Charger-12
Z3** = Bypass/Isolation G = 260 I = NEMA 3R 92 = 220/380V, 3PH, 4W, 50Hz (see full product #14-1/0-GB1 B = 80kA Volt-3 Amp
Horizontal Construction I = 400 w/Adapter Bay 50 = 480V, 3PH, 3W, 60Hz brochure for 2 = Ground bus- C = 100kA
J = 600 J = NEMA 3R/Heater 38 = 120/208/240V, 3PH, 4W, other options) 2 = Battery
* 1600-3000 Amperage Application Mech Lugs 1600A - 4000A Rating
K = 800 & Thermostat/ High-Leg Delta, 60Hz Charger-12
Excluded S = Util-Gen (Qty. 6) X = None
L = 1000 Adapter Bay 30 = 240V, 3PH, 3W, 60Hz Volt-10 Amp
** Applicable to U = Util-Util #8-1/0 -GB2 D = 100kA
M = 1200 G = Gen-Gen K = NEMA 4 31 = 208V, 3PH, 3W, 60Hz E = 150kA (see full product
1600-3000 Amperage (see full product
N = 1600 w/Adapter Bay 61 = 347/600V, 3PH, 4W, 60Hz F = 200kA brochure for
brochure for
O = 2000 L = NEMA 12 (see full product brochure other options) G = 300kA other options)
P = 2600 Controller w/Adapter Bay for other options (see full product
Q = 3000 Language M= NEMA 4X Control brochure for
R = 4000 1 = English Controller Group Options Lug Options Communications other options)
w/Adapter Bay A = Group A X = Std lugs or Rear bus X = None
B = Group B (per chart below) S = CCM S-Modbus RTU (Serial) communication module
C = Group C E = CCM E Modbus TCP/IP (Ethernet) communication module
(see full product brochure
D = Group D E = plus Modbus RTU (Serial) communication module
for lug option details)
M = Group M

ZBTE Model, Dimensions and Weights


NEMA 1 Enclosed Weight Application
Ampere Rating Poles Height (A) Width (B) Depth (C) Ref. Figure Open Type NEMA 1 Notes
100, 150
2, 3 83 (2109) 30 (762) 28.5 (724) 310 (141) 1280 (580)
225, 260 A 1-7
4 83 (2109) 30 (762) 28.5 (724) 380 (173) 1385 (628)
400
2, 3 90 (2286) 36 (914) 28.25 (737) 660 (299) 1435 (651)
600
4 90 (2286) 40 (1016) 28.25 (737) 770 (349) 1540 (699)
B 1-8
800, 1000 2, 3 90 (2286) 40 (1016) 28.25 (737) 765 (347) 1485 (674)
1200 4 90 (2286) 46 (1168) 28.25 (737) 910 (413) 1590 (721)
1600, 2000 2, 3 80 (2023) 40.6 (1031) 64.6 (1640) 1978 (897) 4044 (1835)
1-6, 8-10
2600 4 80 (2023) 46.1 (1171) 64.6 (1640) 2275 (1032) 4431 (2010)
C
3 80 (2023) 40.6 (1031) 64.6 (1640) 2572 (1166) 4456 (2021)
3000
4 80 (2023) 46.1 (1171) 64.6 (1640) 3049 (1383) 4977 (2258)
1-6, 8-11
3 90 (2286) 47.5 (1206) 80.8 (2051) 4310 (1955) 4730 (2145)
4000 D
4 90 (2286) 54 (1372) 80.8 (2051) 5510 (2499) 5930 (2690)

Application Notes AL-CU UL Listed Mechanical Lugs


1. Metric dimensions (cm) and weights (Kg) shown in Normal, Emergency & Load Terminals
parenthesis adjacent to English measurements in Switch Size Amps Cables/Pole Wire Ranges
inches and pounds.
ZBTE
2. Includes 1.25" door projection beyond base depth.
Allow a minimum of 3" additional depth for projec- 100, 150, 225 1 #3/0 to 250 MCM
tion of handle, light, switches, pushbuttons, etc. 260 1 #4 to 600 MCM
3. All dimensions and weights are subject to change 400 1 #4 to 600 MCM
without notice. 600 2 #2 to 600 MCM
4. NEMA 3R, 4, 4X and 12 enclosure dimensions may 800, 1000, 1200 4 #2 to 600 MCM
differ than NEMA 1 shown above. Consult the factory 1600, 2000, 2600, 3000, 4000 * *
for details. Notes:
5. Special lug arrangements may require different en- * Line and load terminals are located in rear and
closure dimensions. See full product brochure (DEA- arranged for bus bar connection. Terminal lugs are
405) for details. available as an accessory. See full product brochure
6. Packing materials must be added to weights shown. (DEA-405) for option details.
Allow 15% additional weight for cartons, skids,
1. Fully rated neutral provided on 3 phase, 4 wire system
crates, etc.
7. Add 4" in height for removable lifting lugs.
8. ZBTE 600-1200A standard configuration is top entry. UL 1008 Withstand and Closing Ratings
14" rear adapter bay required for bottom entry. Con-
sult the factory for details. Please refer to GE Publication TB-1102
9. Bypass switch weights for 1600-4000A units vary up
to 10% based on connections variations. Weights
shown are for estimation only. Consult the factory
for details.
10. 1600-4000A switches have ventilation louvers on
both sides and rear of enclosure. Louvers must be
clear for airflow with standard cable connections.
11. Lug adapters for 3000-4000A limits may be stag-
gered length for ease of cable entrance. Consult the
factory for details.

Rev. 11/13 www.geindustrial.com BuyLog Catalog 14-39


Data subject to change
without notice
Automatic Transfer Switches Section 14
Critical Power Products
Model ZBTED

ZBTED Series
Low-Voltage, Bypass/Isolation Delayed Transition, Automatic and
Manual Transfer Switches
Ideal for inductive (motors/transformers, UPS) mission
critical loads Control Group Options (see order code)
Adjustable ATS time delay in center off position
Group A: All standard features, Field re-programmable I/O
Bypass/Isolation for ease of ATS maintenance/testing without
(4 inputs, 4 outputs), Control Switches (Test with Load, Test no
load loss of power
load, Fast Test, Alarm Reset, Auto/Man Re-transfer Source 1,
Ratings 100 to 4000 amperes
Auto/Man Transfer both sources, Preferred Source select,
Ratings & Construction Commit/No Commit Transfer to Gen, Time Delay Bypass
Ratings Voltage, Ampere and Pole configuration per Group B: All features from A plus: 10 User-configurable Analog
Order Code & 10 Digital Alarms, 20-channel data logger, 10-channel wave-
Certifications UL 1008, CSA C22.2 form capture, Auto Load Shed (with voltage, frequency, and
Certifications Third-party Seismic Certification to IBC 2009, kW triggers)
3.2g @ Ip = 1.5 (operation during event) Group C:All features from Bplus: 4 additional field programma-
Electrical Operator Momentarily energized, high-speed ble inputs (total 8 inputs, 8 outputs)
solenoid mechanism Group D:All features from Cplus: 4 additional field programma-
Mechanism Mechanically-held with mechanical interlock to ble inputs (total 12 inputs, 12 outputs) & GE Flexlogic user-
inhibit connection of both sources to the load configurable control logic
Contacts GE design and manufactured, silver tungsten alloy Group M: Manual ATS configuration
with separate arcing contacts on 600A and above ratings for Additional Standard Features
high withstand and close-on capability
Engine Exerciser Configurable Periodic Exerciser (7 Event
Neutral Pole (4 pole only) Identical construction to phase
Daily, Weekly, 14 or 28 day) or Clock Exerciser Type (21 Event,
poles with fully rated main and arcing contacts. Operation via
365 day Programmable)
same mechanism as phase poles to prevent sustained connec-
System Status Screen Active state of switch, display of all time
tion of source neutrals in separately derived systems, as last-
delays and alarm conditions
break/ first-make transfer.
Event Recorder 256 Event, 1ms accuracy, clock sync via
Controller Network Time Protocol (NTP)
Construction Dual-processor based, with dedicated processor Outage & Test Report Screen Date/time stamping of: outage
for high-speed Serial or Ethernet communications or test event, start signal sent, Gen start time, connection to
Source Sensing Direct 120-690V sensing and software config- Gen, Max Gen Volts & Freq dip, return of utility, re-transfer
uration of rated voltage and frequency without the need for to normal
potential transformers, step-down transformers or DIP switches External Power Supply Standard 120VAC input for controller
Control Wiring All customer connections at one location. All power and communication and 24 VDC input for remote control
signals in/out relay-isolated via DIN-mounted relay/terminal and annunciation when both sources de-energized
blocks. All control wiring via factory-installed wiring harnesses. Flexible Feature Assignment Field reassignable I/O for any/all
control features
Enclosure
Programmable Center-Off Position For transition of motor
Type per Order Code and regenerative loads
Display, Sensing & Time Delays Optional Features (see order code)
Display VGA color graphical with embedded HELP menus Serial Communications High speed, up to 115k Baud
Annunciation High intensity LED for Source Availability (2), Modbus RTU
Source Connected (2), Transfer Inhibit (not in Auto) Ethernet Communications Fast Ethernet, (10/100 Mbit),
Source Fail/Restore Independently adjustable pickup & Modbus TCP/IP
dropout of 3-phase U/O voltage, U/O Freq, Volts Balance plus Power Quality Metering True RMS metering, including THD%
Phase Rotation
Time Delays Gen start, Source 2 stabilize, S1 g S2 transfer
(up to 8th order)
Load Shed Ability to transfer to de-energized normal source or
center-off delay, Source 2 fail override, Retransfer to Source 1,
S2 g S1 transfer center-off delay, Gen cool down, Independent
center position in event of generator overload
Integral Surge Protective Device (SPD) Load-connected
settings for Fast Test, Time Delay for Generator Voltage Sag medium or high exposure type
Remote Access All parameters locally (front USB port) or re- Integral Battery Charger 3 or 10A, 12 or 24VDC type
motely (serial or Ethernet) Adjustable Lugs Compression lugs in lieu of standard mechanical lugs on
100A-1200A switches
Lugs Mechanical or Compression lugs in lieu of standard rear-
bus connection on 1600-4000A switches

14-40 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Automatic Transfer Switches Section 14
Critical Power Products
Model ZBTED

Order Code Abbreviated Product Configuration


(see full Product Brochure, Publication DEA-405, for full configuration)

Z D X
Ground Bus SPD Battery
Product Type Operation Amperage # of Poles NEMA Enclosure Voltage Code Metering & X = None (Load-Side Connected) Charger
Z2*** = Bypass/ D = Delayed C = 100 2 = 2 Pole X = None (Open) 70 = 277/480V, 3PH, 4W, 60Hz Accessories
1 = Ground bus- 100A - 1200A Rating X = None
X = None
Isolation Vertical Transition D = 150 3 = 3 Pole H = NEMA 1 20 = 120/240V, 1PH, 3W, 60Hz A = Load Shed Mech Lugs X = None 1 = Battery
Construction F = 225 4 = 4 Pole w/Adapter Bay 40 = 120/208V, 3PH, 4W, 60Hz D = PQ Metering (Qty. 3) A = 65kA Charger-12
Z3** = Bypass/Isolation G = 260 I = NEMA 3R 92 = 220/380V, 3PH, 4W, 50Hz (see full product #14-1/0-GB1 B = 80kA Volt-3 Amp
Horizontal Construction I = 400 w/Adapter Bay 50 = 480V, 3PH, 3W, 60Hz brochure for 2 = Ground bus- C = 100kA
J = 600 J = NEMA 3R/Heater 38 = 120/208/240V, 3PH, 4W, other options) 2 = Battery
* 1600-3000 Amperage Application Mech Lugs 1600A - 4000A Rating
K = 800 & Thermostat/ High-Leg Delta, 60Hz Charger-12
Excluded S = Util-Gen (Qty. 6) X = None
L = 1000 Adapter Bay 30 = 240V, 3PH, 3W, 60Hz Volt-10 Amp
** Applicable to U = Util-Util #8-1/0 -GB2 D = 100kA
M = 1200 G = Gen-Gen K = NEMA 4 31 = 208V, 3PH, 3W, 60Hz E = 150kA (see full product
1600-3000 Amperage (see full product
N = 1600 w/Adapter Bay 61 = 347/600V, 3PH, 4W, 60Hz F = 200kA brochure for
brochure for
O = 2000 L = NEMA 12 (see full product brochure other options) G = 300kA other options)
Q = 3000 Controller w/Adapter Bay for other options (see full product
R = 4000 Language M= NEMA 4X Control brochure for
1 = English Controller Group Options Lug Options Communications other options)
w/Adapter Bay A = Group A X = Std lugs or Rear bus X = None
B = Group B (per chart below) S = CCM S-Modbus RTU (Serial) communication module
C = Group C E = CCM E Modbus TCP/IP (Ethernet) communication module
(see full product brochure
D = Group D E = plus Modbus RTU (Serial) communication module
for lug option details)
M = Group M

ZBTED Model, Dimensions and Weights Application Notes


NEMA 1 Enclosed Weight Application 1. Metric dimensions (cm) and weights (Kg) shown in
Ampere Rating Poles Height (A) Width (B) Depth (C) Ref. Figure Open Type NEMA 1 Notes parenthesis adjacent to English measurements in
100, 150 inches and pounds.
2, 3 310 (141) 1280 (580)
225, 260 83 (2109) 30 (762) 28.5 (724) A 2. Includes 1.25" door projection beyond base depth.
4 380 (173) 1385 (628)
400 Allow a minimum of 3" additional depth for projec-
600
3 90 (2286) 36 (914) 28.3 (737) 660 (299) 1435 (651) 1-7, 9 tion of handle, light, switches, pushbuttons, etc.
4 90 (2286) 40 (1016) 28.3 (737) 770 (349) 1540 (699) 3. All dimensions and weights are subject to change
B
800, 1000 3 90 (2286) 40 (1016) 28.3 (737) 765 (347) 1485 (674) without notice.
1200 4 90 (2286) 46 (1168) 28.3 (737) 910 (413) 1590 (721) 4. NEMA 3R, 4, 4X and 12 enclosure dimensions may
1600, 2000 3 80 (2023) 40.6 (1031) 64.6 (1640) 1978 (897) 4044 (1835) differ than NEMA 1 shown above. Consult the factory
1-6, 10
2600 4 80 (2023) 46.1 (1171) 64.6 (1640) 2275 (1032) 4431 (2010)
C for details.
3 80 (2023) 40.6 (1031) 64.6 (1640) 2572 (1166) 4456 (2021)
3000 5. Special lug arrangements may require different en-
4 80 (2023) 46.1 (1171) 64.6 (1640) 3049 (1383) 4977 (2258) 1-6,
closure dimensions. See full product brochure (DEA-
3 90 (2286) 47.5 (1206) 80.8 (2051) 4310 (1955) 4730 (2145) 8, 10
4000
4 90 (2286) 54 (1372) 80.8 (2051)
D
5510 (2499) 5930 (2690)
405) for details.
6. Packing materials must be added to weights shown.
Allow 15% additional weight for cartons, skids,
crates, etc.
7. Add 4" in height for removable lifting lugs.
8. Lug adapters for 3000-4000A limits may be stag-
gered length for ease of entrance. Consult the fac-
tory for details.
9. 100-1200A standard configuration is top cable entry.
14" adapter bay is required for bottom cable entry.
Consult the factory for details.
10. 1600-4000A switches have ventilation louvers on
both sides and rear of enclosure. Louvers must be
clear for airflow with standard cable connections.

AL-CU UL Listed Mechanical Lugs


ZBTED Model Delayed Transition UL 1008 Withstand and Closing Ratings Normal, Emergency & Load Terminals

Transfer/Bypass-Isolation Switches Switch Size Amps Cables/Pole Wire Ranges


Please refer to GE Publication TB-1102
ZBTED
The ZTED Delayed Transition Transfer Switch
100, 150, 225 1 #3/0 to 250 MCM
with a timed center-off position is available in a 260 1 #4 to 600 MCM
bypass configuration. The ZBTED Model Bypass 400 1 #4 to 600 MCM
incorporates the features of both the ZBTE 600 2 #2 to 600 MCM
800, 1000, 1200 4 #2 to 600 MCM
Bypass-Isolation Switch and the ZTED unit for 1600, 2000, 2600, 3000, 4000 * *
transfer of large motor loads, transformers, Notes:
UPS systems or load shedding to a neutral * Line and load terminals are located in rear and
Off position. Reference the ZTED unit features arranged for bus bar connection. Terminal lugs are
and operation discussion for more details. available as an accessory. See full product brochure
(DEA-405) for option details.
1. Fully rated neutral provided on 3 phase, 4 wire system

Rev. 11/13 www.geindustrial.com BuyLog Catalog 14-41


Data subject to change
without notice
Automatic Transfer Switches Section 14
Critical Power Products
Model ZBTECT

ZBTECT Series
Low-Voltage, Bypass/Isolation Closed Transition, Automatic and
Manual Transfer Switches
Ideal for mission critical loads (computer servers, HID emergency
lighting, data acquisition equipment)
Control Group Options (see order code)
Two source parallel time (bumpless transfer) of less than
100 milliseconds Group A: All standard features, Field re-programmable I/O
Bypass/Isolation for ease of ATS maintenance/testing without (4 inputs, 4 outputs), Control Switches (Test with Load, Test no
load loss of power load, Fast Test, Alarm Reset, Auto/Man Re-transfer Source 1,
Ratings 100 to 4000 amperes Auto/Man Transfer both sources, Preferred Source select,
Commit/No Commit Transfer to Gen, Time Delay Bypass
Ratings & Construction Group B: All features from A plus: 10 User-configurable Analog
Ratings Voltage, Ampere and Pole configuration per & 10 Digital Alarms, 20-channel data logger, 10-channel wave-
Order Code form capture, Auto Load Shed (with voltage, frequency, and
Certifications UL 1008, CSA C22.2 kW triggers)
Certifications Third-party Seismic Certification to IBC 2009, Group C: All features from B plus: 4 additional field
3.2g @ Ip = 1.5 (operation during event) programmable inputs (total 8 inputs, 8 outputs)
Electrical Operator Momentarily energized, high-speed Group D: All features from C plus: 4 additional field
solenoid mechanism programmable inputs (total 12 inputs, 12 outputs) & GE Flexlogic
Mechanism Mechanically-held with highspeed transfer user-configurable control logic
mechanism for make-before break closed transition transfers Group M: Manual ATS configuration
Contacts GE design and manufactured, silver tungsten alloy
Additional Standard Features
with separate arcing contacts on 600A and above ratings for
high withstand and close-on capability Engine Exerciser Configurable Periodic Exerciser (7 Event
Neutral Pole (4 pole only) Identical construction to phase Daily, Weekly, 14 or 28 day) or Clock Exerciser Type (21 Event,
poles with fully rated main and arcing contacts. Operation via 365 day Programmable)
same mechanism as phase poles to prevent sustained connec- System Status Screen Active state of switch, display of all time
tion of source neutrals in separately derived systems, as last- delays and alarm conditions
break/first-make transfer. Event Recorder 256 Event, 1ms accuracy, clock sync via Net-
work Time Protocol (NTP)
Controller Outage & Test Report Screen Date/time stamping of: outage
Construction Dual-processor based, with dedicated processor or test event, start signal sent, Gen start time, connection to
for high-speed Serial or Ethernet communications Gen, Max Gen Volts & Freq dip, return of utility, re-transfer
Source Sensing Direct 120-690V sensing and software config- to normal
uration of rated voltage and frequency without the need for External Power Supply Standard 120VAC input for controller
potential transformers, step-down transformers or DIP switches power and communication and 24 VDC input for remote control
Control Wiring All customer connections at one location. All and annunciation when both sources de-energized
signals in/out relay-isolated via DIN-mounted relay/terminal Flexible Feature Assignment Field reassignable I/O for any/all
blocks. All control wiring via factory-installed wiring harnesses. control features
Enclosure Fail to Sync and Extended Parallel Protection Hardwired,
independent controller
Type per Order Code
Optional Features (see order code)
Display, Sensing & Time Delays
Serial Communications High speed, up to 115k Baud
Display VGA color graphical with embedded HELP menus Modbus RTU
Annunciation High intensity LED for Source Availability (2), Ethernet Communications Fast Ethernet, (10/100 Mbit),
Source Connected (2), Transfer Inhibit (not in Auto) Modbus TCP/IP
Source Fail/Restore Independently adjustable pickup & Power Quality Metering True RMS metering, including THD%
dropout of 3-phase U/O voltage, U/O Freq, Volts Balance plus (up to 8th order)
Phase Rotation Load Shed Ability to transfer to de-energized normal source or
Time Delays Gen start, Source 2 stabilize, Source 2 fail center position in event of generator overload
override, Retransfer to Source 1, Gen cool down, Independent Integral Surge Protective Device (SPD) Load-connected
settings for Fast Test, Time Delay for Generator Voltage Sag medium or high exposure type
Remote Access All parameters locally (front USB port) or Integral Battery Charger 3 or 10A, 12 or 24VDC type
remotely (serial or Ethernet) Adjustable Lugs Compression lugs in lieu of standard mechanical lugs on
100A-1200A switches
Lugs Mechanical or Compression lugs in lieu of standard rear-
bus connection on 1600-4000A switches

14-42 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Automatic Transfer Switches Section 14
Critical Power Products
Model ZBTECT

Order Code Abbreviated Product Configuration


(see full Product Brochure, Publication DEA-405, for full configuration)

Z C X
Ground Bus SPD Battery
Product Type Operation Amperage # of Poles NEMA Enclosure Voltage Code Metering & X = None (Load-Side Connected) Charger
Z2*** = Bypass/ C = Closed C = 100 2 = 2 Pole X = None (Open) 70 = 277/480V, 3PH, 4W, 60Hz Accessories
1 = Ground bus- 100A - 1200A Rating X = None
X = None
Isolation Vertical Transition D = 150 3 = 3 Pole H = NEMA 1 20 = 120/240V, 1PH, 3W, 60Hz A = Load Shed Mech Lugs X = None 1 = Battery
Construction F = 225 4 = 4 Pole w/Adapter Bay 40 = 120/208V, 3PH, 4W, 60Hz D = PQ Metering (Qty. 3) A = 65kA Charger-12
Z3** = Bypass/Isolation G = 260 I = NEMA 3R 92 = 220/380V, 3PH, 4W, 50Hz (see full product #14-1/0-GB1 B = 80kA Volt-3 Amp
Horizontal Construction I = 400 w/Adapter Bay 50 = 480V, 3PH, 3W, 60Hz brochure for 2 = Ground bus- C = 100kA
J = 600 J = NEMA 3R/Heater 38 = 120/208/240V, 3PH, 4W, other options) 2 = Battery
* 1600-3000 Amperage Application Mech Lugs 1600A - 4000A Rating
K = 800 & Thermostat/ High-Leg Delta, 60Hz Charger-12
Excluded S = Util-Gen (Qty. 6) X = None
L = 1000 Adapter Bay 30 = 240V, 3PH, 3W, 60Hz Volt-10 Amp
** Applicable to U = Util-Util #8-1/0 -GB2 D = 100kA
M = 1200 G = Gen-Gen K = NEMA 4 31 = 208V, 3PH, 3W, 60Hz E = 150kA (see full product
1600-3000 Amperage (see full product
N = 1600 w/Adapter Bay 61 = 347/600V, 3PH, 4W, 60Hz F = 200kA brochure for
brochure for
O = 2000 L = NEMA 12 (see full product brochure other options) G = 300kA other options)
P = 2600 Controller w/Adapter Bay for other options (see full product
Q = 3000 Language M= NEMA 4X Control brochure for
R = 4000 1 = English Controller Group Options Lug Options Communications other options)
w/Adapter Bay A = Group A X = Std lugs or Rear bus X = None
B = Group B (per chart below) S = CCM S-Modbus RTU (Serial) communication module
C = Group C E = CCM E Modbus TCP/IP (Ethernet) communication module
(see full product brochure
D = Group D E = plus Modbus RTU (Serial) communication module
for lug option details)
M = Group M

ZBTECT Model, Dimensions and Weights Application Notes


NEMA 1 Enclosed Weight Application 1. Metric dimensions (cm) and weights (Kg) shown in
Ampere Rating Poles Height (A) Width (B) Depth (C) Ref. Figure Open Type NEMA 1 Notes parenthesis adjacent to English measurements in
100, 150, 225 2, 3 730 (331) 1280 (580) inches and pounds.
90 (2286) 36 (914) 28.5 (724)
260, 400 4 840 (381) 1385 (628) 2. Includes 1.25" door projection beyond base depth.
3 90 (2286) 36 (914) 28.3 (737) 730 (331) 1435 (651) Allow a minimum of 3" additional depth for projection
600 A 1-7, 9
4 90 (2286) 40 (1016) 28.3 (737) 840 (381) 1540 (699) of handle, light, switches, pushbuttons, etc.
800, 1000 3 90 (2286) 40 (1016) 28.3 (737) 835 (379) 1485 (674) 3. All dimensions and weights are subject to change
1200 4 90 (2286) 46 (1168) 28.3 (737) 980 (444) 1590 (721) without notice.
1600, 2000 3 80 (2023) 40.6 (1031) 64.6 (1640) 1978 (897) 4044 (1835) 4. NEMA 3R, 4, 4X and 12 enclosure dimensions may
1-6, 10
2600 4 80 (2023) 46.1 (1171) 64.6 (1640) 2275 (1032) 4431 (2010) differ than NEMA 1 shown above. Consult the factory
B
3 80 (2023) 40.6 (1031) 64.6 (1640) 2572 (1166) 4456 (2021)
3000 for details.
4 80 (2023) 46.1 (1171) 64.6 (1640) 3049 (1383) 4977 (2258) 1-6,
5. Special lug arrangements may require different en-
3 90 (2286) 47.5 (1206) 80.8 (2051) 4380 (1986) 4730 (2145) 8, 10
4000 C closure dimensions. See full product brochure (DEA-
4 90 (2286) 54 (1372) 80.8 (2051) 5580 (2531) 5930 (2690)
405) for details.
6. Packing materials must be added to weights shown.
Allow 15% additional weight for cartons, skids,
crates, etc.
7. Add 4" in height for removable lifting lugs.
8. Lug adapters for 3000-4000A limits may be stag-
gered length for ease of entrance. Consult the
factory for details.
9. 100-1200A standard configuration is top cable entry.
14 adapter bay is required for bottom cable entry.
Consult the factory for details.
10. 1600-4000A switches have ventilation louvers on
both sides and rear of enclosure. Louvers must be
clear for airflow with standard cable connections.

AL-CU UL Listed Mechanical Lugs


Normal, Emergency & Load Terminals

ZBTECT Model Closed Transition UL 1008 Withstand and Closing Ratings Switch Size Amps Cables/Pole Wire Ranges
ZBTECT
Transfer/Bypass-Isolation Switches Please refer to GE Publication TB-1102
100, 150, 225, 260, 400 1 #4 to 600 MCM
The ZTECT Closed Transition Transfer Switch 600 2 #2 to 600 MCM
may be applied with a bypass-isolation switch 800, 1000, 1200 4 #2 to 600 MCM
for the utmost in reliability and versatility. The 1600, 2000, 2600, 3000, 4000 * *

ZBTECT Model provides the ability to withdraw Notes:


the transfer switch unit for maintenance or * Line and load terminals are located in rear and
arranged for bus bar connection. Terminal lugs are
inspection. Reference the ZTECT unit features available as an accessory. See full product brochure
and operation discussion for more details. (DEA-405) for option details.
1. Fully rated neutral provided on 3 phase, 4 wire system

Rev. 11/13 www.geindustrial.com BuyLog Catalog 14-43


Data subject to change
without notice
Automatic Transfer Switches Section 14
NOTES:

14-44 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Section Updated 12 / 2016
Motor Control CentersLow Voltage Section 15

E9000

Motor Control Centers Introduction .......................................15-2 EVOLUTION SERIES E9000/8000 Low Voltage
EVOLUTION SERIES E9000 Key Benefits ...............................15-3 Motor Control Centers
Motor Control Centers Features (SC/MC Program)..............15-4
Product References:
GE Fastrac Program MCC Units Quick Selection Guide, E9000 Engineered Products Catalog Section 10
Motor Control Starter Units.................................................................15-5 Application and Selection Guide E9000 DET291A
Motor Control Feeder Units.................................................................15-9 Application and Selection Guide Spectra/8000 GET6729

MCC Sections ..........................................................................................15-11


Renewal Parts.........................................................................................15-13
GE Fastrac Program MCC Units Quick Selection Guide,
CR8000
Motor Control Starter Units..............................................................15-14
Motor Control Feeder Units..............................................................15-18
Renewal Parts.........................................................................................15-19

Rev. 11/13 www.geindustrial.com BuyLog Catalog 15-1


Data subject to change
without notice
Motor Control CentersLow Voltage Section 15
GE Motor Control Centers

Introduction
GE motor control centers offer an ideal means of quickly providing
centralized motor control and other related control equipment.
A pre-engineered version of the GE motor control center is avail-
able at short-cycle and mid-cycle shipment. The product scope
available is more limited than with normal cycle shipments, and
includes certain combination starter units, feeder units, distribu-
tion transformers, lighting panels, relaying panels, programmable
controllers and other miscellaneous devices to be installed in a
single, floor-mounted enclosure and fed from a common
enclosed horizontal and vertical bus system.
Each GE motor control center vertical section is constructed of
0.090-inch (13-gauge) steel which is subjected to a special corro-
sion-resistant zinc-phosphate treatment followed by a powder
paint process using ANSI-61 light gray alkyd-enamel paint. Refer
to the factory for additional color options. Each section houses
the horizontal and vertical bus, horizontal and vertical wireways
and the compartmentalized individual control units. Standard
unit construction is Class I Type B wiring1. Factory assembled,
wired and tested units are mounted in each vertical section,
and sections are easily bolted together to form a motor control
center line-up. The entire line-up is then powered by a single
incoming-line connection.
Standard UL labeled NEMA 1 enclosure contains 600-ampere,
three-phase, copper tin-plated horizontal main bus, 300-ampere,
three-phase, copper tin-plated vertical bus and is braced to
withstand a fault current of 65,000 rms symmetrical. Each verti-
cal section must be priced to include 72 inches of vertical space
units consisting of starters, feeders, transformers, panels, incom-
ing terminal boards and/or enclosure spaces for future units.
1Typical diagrams can be found in the Application and Selection Guide for DET291
Section L.

15-2 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Motor Control CentersLow Voltage Section 15
GE Motor Control Centers
EVOLUTION SERIES E9000 Key Benefits

Safety:
No Hot bus rework up to 600A
Hi-Visible Trip Indication
Door and unit interlocks
UBC Seismic Zone 4 Standard
Six Sigma Designed

Size:
6" reductionSz 3, 5
6" to 36" reduction VFDs
6" Size 1 FVNR
6" 150A Feeder
12" 250A Feeder
36" Size 5 Plug-In, two in a section
300VA CPTNo additional Space
Plug In Buckets to Size 5
Plug In Feeders to 600A

Simplicity:
Easy Unit Insertion/Removal
Snap-In Shelves
Easily Quoted Fastrac MCCs
Manufacturing Flexibility

Scope:
450 Hp VFDs
500 Hp SSS
250A and 600A Stabs
TVSS 65-200K Surge Current
Automatic Transfer Switches to 1200A

Rev. 11/13 www.geindustrial.com BuyLog Catalog 15-3


Data subject to change
without notice
Motor Control CentersLow Voltage Section 15
GE Motor Control Centers
Short/Mid Cycle Program

Features Highlights of the Evolution SC/MC Program:


The Evolution SC/MC is a pre-engineered, factory assembled, fully
I Structure (20-inch wide is standard)
tested motor control center that contains all the standard fea-
13- or 20-inch deep
tures of the Evolution motor control center, including some
Back-to-back mounting (20-inch deep only)
options.
NEMA 1 gasket, 2, 12, 3R non-walk-in
24-inch wide enclosures
All sections and units will be UL labeled where possible. Refer to
Corner section enclosures
Company if labeling is critical.
Special enclosures
Engraved nameplates (optional)
Please contact your distributor or GE for scope, pricing, and
Addition of Field Installed Kits
ordering.
II Bus Systems
No changes are allowed to Evolution SC/MC bill-of- Voltage: 208, 240, 480, 575 volts
material after order entry. 3-phase, 3-wire, or 3-phase, 4-wire
Main bus: 600, 800, 1000, 1200 ampere
Vertical bus: 300, 450, 600 ampere, section-by-section
Optional ground bus: 300, 375, 600 ampere
Neutral bus: 300, 400, 600, 800, 1000 ampere
Optional silver plating
Back-to-back construction (rear vertical bus)
Vertical Bus Plugs installed in unused stab openings
III Incoming Line
600 amperes with 18 inches of pull space
Circuit breakers thru 1200 amperes
Fusible switches thru 600 amperes
IV Feeders and Mains
Feeders800-ampere Spectra
Feeders600-ampere fused switch
Main1200-ampere Spectra
Shunt trip and UV release
V Combination Starter Units
Control Power Transformer (CPT) (optional)
Extra auxiliary interlocks (optional)
Line-to-line control
Line-to-neutral control
Separate control power or common CPT
FVNRSize 1 thru 6
FVRSize 1 thru 4
RVNRSize 2 thru 5
2S2WSize 1 thru 4
2S1WSize 1 thru 4
NEMA Type 1B wiring
Interlocks mounted on circuit breaker and
fusible switch (optional)

15-4 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Motor Control CentersLow Voltage Section 15
GE Fastrac ProgramMCC Units Quick Selection Guide
EVOLUTION SERIES E9000

This Quick Selection Guide covers Control Center starters and 2 Select Starter Type and Size
feeders, including full and reduced voltage, reversing and non- Find the starter type required. Transfer the product number digits
reversing, two-speed single and dual winding starters, in sizes to the boxes marked 2 in the product number.
1-5. It also covers EVOLUTION SERIES E9000 Sections. For
other units, see the Engineered Products Catalog, Section 10. Starter Type Size Product Number Digits
1 H1 1

Motor Control Starter Units 1 A1


2 A2
For each of the following steps, find the optionMCC type, starter FVNR
3 A3
type, size, disconnect, control power, pilot lights, etc. that meets
4 A4
the need. Transfer the corresponding product number digit(s) to
5 A5
the product number box(es).
1 B1
When you have finished, you will have built a complete product 2 B2
FV R
number. 3 B3
4 B4
1 Select Motor Control Center Type 1 C1
2S1W 2 C2
Select motor control center type. Transfer the product number Variable
3 C3
digits to the box marked 1 in the product number line. Torque
4 C4
1 D1
MCC Type Product Number Digit 2S2W 2 D2
EVOLUTION SERIES E9000 E Variable
Torque 3 D3
4 D4
2 E2
3 E3
RVNR
4 E4
5 E5
1H1 is a 6" 10HP compact starter.

All Fastrac units have the following as standard:


A. NEMA 12 gasketing
B. Isolated N.O. overload alarm contact (not wired to TB)
C. Auxiliary contacts wired to the TB as noted below:
FVNR and RVNR Starters(1) N.O. (1) N.C.
FVR and 2S Starters(1) N.O. per contactor

Note: Contact Factory for pricing.

Rev. 11/13 www.geindustrial.com BuyLog Catalog 15-5


Data subject to change
without notice
Motor Control CentersLow Voltage Section 15
GE Fastrac ProgramMCC Units Quick Selection Guide
EVOLUTION SERIES E9000

3 Select Starter Disconnect 4 Select Control Power


Use the first table to identify desired disconnect device. (Note that Standard control power transformer (CPT) ratings are adequate to
these are for basic applications; see publication DET-291 for handle the starter-coil current and three pilot lights. If additional
EVOLUTION SERIES E9000 for more information.) Then, from the burdens are expected, larger transformers should be specified
second table select starter disconnect. Transfer the product from among those shown in the first table below. From the
number digit to the box marked 3 in the product number line. second table below, select the control power desired. Transfer
If H1 is selected in Step 2 , product number digits U or W must the product number digit to the box marked 4 in the product
be selected. number line. If H1 is selected in Step 2 , product number digits 1
Starter Mag Only Thermal Mag
Short Circuit Rating or 5 must be selected. Product number digit 1 is for 100VA CPT.
Size Circuit Breaker Circuit Breaker 230V 460V 575V1 Starter Type and Size CPT Std. VA Oversize VA
Spectra - 65k Spectra - 65k 65 65 25 All Size 1 60 150
1, 2, 3
Spectra -100k Spectra - 100k 100 100 All Size 2 150
Spectra - 65k Spectra - 65k 65 65 25 All Size 3 300
4
Spectra - 100k Spectra - 100k 100 100 All Size 4 300

Spectra - 65K Spectra - 65K 65 65 65 All Size 5 100


5
Spectra - 100K Spectra - 100K 100 100 100
1 At 575V current limiters may be used.

Product Control Product


Starter Size Starter Size
Disconnect Number Power Number
Device Digit 1 2 3 4 5 (120 Vac)4 Digit 1 2 3 4 5
FSW-R F Std. CPT 1
FSW-J3 R
Oversize 2
Spectra 65
U Line-to-Line 4
Mag Only2
Spectra 100 Common/
V Separate 5
Mag Only
Source
Spectra 65 4At 380V 50Hz, Control Volts will be 110Vac; at 575V 60Hz, Control Volts
W
Thermal Mag2
will be 115Vac.
Spectra 100 X
Thermal Mag
2 25KAIC @ 575V.
3J time delay.

Note: Contact Factory for pricing.

15-6 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Motor Control CentersLow Voltage Section 15
GE Fastrac ProgramMCC Units Quick Selection Guide
EVOLUTION SERIES E9000

5 Select Pilot Devices 5 Select Pilot Devices (continued)


Select pilot devices desired by starter type. See Pilot Devices Starter Incandescent LED
Type Pilot Device Product Number Digits Product Number Digits
table below and note the lamp type as either Incandescent or
LED. Transfer the product number digits to the boxes marked 5 NONE - Blank Pilot Device
NN* -
Bracket Provided
in the product number line. If H1 is selected in Step 2 , a pilot RED/AMBER LGT STD EF SF
device with an asterisk (*) must be selected. RED/AMBER LGT PTT ES SS
R/A/G LGT STD EG SG
Starter Incandescent LED
Type Pilot Device Product Number Digits Product Number Digits R/A/G LGT PTT ET ST
FAST/SLOW/STOP PB EN -
NONE - Blank Pilot Device
NN* - FAST/SLOW/STOP PB R/A LGT STD EB SB
Bracket Provided 2S1W &
2S2W FAST/SLOW/STOP PB R/A LGT PTT EP SP
RED LGT STD AE* OE*
RED LGT PUSH-TO-TEST (PTT) AF OF FAST/SLOW/STOP PB R/A/G LGT STD EC SC

RED/GREEN LGT STD AS* OS* FAST/SLOW/STOP PB R/A/G LGT PTT EQ SQ

RED/GREEN LGT PTT AT OT FAST/SLOW/OFF/AUTO (F/S/O/A) SW FN -

HAND/OFF/AUTO (H/O/A) SW. AN* - F/S/O/A SW R/A LGT STD FB TB

H/O/A SW. RED LGT STD AB* OB* F/S/O/A SW R/A LGT PTT FP TP

H/O/A SW. RED LGT PTT AP OP F/S/O/A SW R/A/G LGT STD FC TC

H/O/A SW. R/G LGT STD AC* OC* F/S/O/A SW R/A/G LGT PTT FQ TQ

FVNR & H/O/A SW. R/G LGT PTT AQ OQ


RVNR &
6 Select Overload Relay
H/O/A SW. STOP/START PB RED LGT STD AD OD
RVSS
H/O/A SW. STOP/START PB RED LGT PTT AR OR Select overload relay type. Transfer the product number digits
STOP/START PB BN* - to the box marked 6 in the product number line. If H1 is selected
STOP/START PB RED LGT STD BB* PB*
in Step 2 , product number digit 2 must be selected. *If H1 is
STOP/START PB RED LGT PTT BP PP
selected in Step 2 , the overload provided is the Series RT overload.
STOP/START PB R/G LGT STD BC PC
STOP/START PB R/G LGT PTT BQ PQ Relay Type Product Number Digit
OFF/ON SW. GN* -
Standard 1
OFF/ON SW. RED LGT STD GB* UB*
Ambient Compensated 2*
OFF/ON SW. RED LGT PTT GP UP
Solid State 3
OFF/ON SW. R/G LGT STD GC* UC*
OFF/ON SW. R/G LGT PTT GQ UQ
7 Select Control Terminal Board
NONE - Blank Pilot Device
NN* -
Bracket Provided Select control disconnect terminal board. Transfer the product
RED/GREEN LGT STD CE QE number digits to the box marked 7 in the product number line. If
RED/GREEN LGT PTT CR QR H1 is selected in Step 2 , product number digit H must be
RED/AMBER LGT STD CF QF
selected.
RED/AMBER LGT PTT CS QS
R/A/G LGT STD CG QG Control Disconnect Terminal Board Product Number Digit
R/A/G LGT PTT CT QT Standard High-Density H
FWD/REV/STOP PB CN -
FVR
FWD/REV/STOP PB R/A LGT STD CB QB
FWD/REV/STOP PB R/A LGT PTT CP QP 8 Select Horsepower
FWD/REV/STOP PB R/G/A LGT STD CC QC Select horsepower. Transfer the product number digits to the
FWD/REV/STOP PB R/G/A LGT PTT CQ QQ
boxes marked 8 in the product number line. Note that some
FWD/OFF/REV SW DN -
FWD/OFF/REV SW RED LGT STD DB
product number digits consist of a decimal point.
RB
FWD/OFF/REV SW RED LGT PTT DP RP
Horsepower Product Number Digits Horsepower Product Number Digits
FWD/OFF/REV SW R/G LGT STD DC RC
1/4 .25 15 015
FWD/OFF/REV SW R/G LGT PTT DQ RQ
1/3 .33 20 020
3/8 .38 25 025
1/2 .50 30 030
3/4 .75 40 040
1 001 50 050
1 1/2 1.5 60 060
2 002 75 075
3 003 100 100
5 005 125 125
7 1/2 7.5 150 150
10 010 200 200

Note: Contact Factory for pricing.

Rev. 11/13 www.geindustrial.com BuyLog Catalog 15-7


Data subject to change
without notice
Motor Control CentersLow Voltage Section 15
GE Fastrac ProgramMCC Units Quick Selection Guide
EVOLUTION SERIES E9000

9 Select System Voltage 10 OEM Fastrac Units


Select system voltage. Transfer the product number digit to Fastrac units designed for OEM use are engineered and built with
the box marked 9 in the product number line. If H1 is selected in the same components and layout as the standard Fastrac units.
Step 2 , product number digits A or C must be selected. Power wiring is provided: however, to allow the maximum flexibil-
ity for OEM users, no control wiring is provided.
Voltage Product Number Digit
Product numbers are the same as the standard Fastrac units
480V 60 Hz A
with the addition of two additional suffix letters, XX.
208V 60 Hz B
240V 60 Hz C Example:

575V 60 Hz D Standard Fastrac Unit EA1U1AB1H010A

380V 50 Hz E OEM Fastrac Unit EA1U1AB1H010AXX

1 2 3 4 5 6 7 8 9 10
Starter
Product
Number

Note: Contact Factory for pricing.

15-8 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Page Updated 12 / 2016
Motor Control CentersLow Voltage Section 15
GE Fastrac ProgramMCC Units Quick Selection Guide
EVOLUTION SERIES E9000

Motor Control Feeder Units 4 Select Feeder Device


For each of the following steps, find the optionMCC type, Select feeder device from one of the following two tables. Transfer
disconnect type, amp rating, feeder devicesthat meets the the product number digits to the boxes marked 4 in the product
need. Transfer the corresponding product number digits to the number line for either the standard or OEM extended feeder unit.
product number boxes for either the standard or OEM extended
feeder unit. When you have finished, you will have built a complete Standard Feeder Units
product number. Short Circuit
Amp Rating KA Volts Unit Product
Rating Height Number
1 Select Motor Control Center Type Device (Max.) 240 480 600 (Inches) Digits

Select motor control center type. Transfer the product number SELT
150 65 65 25 12 SEL2

digit to the box marked 1 in the product number line. 150 65 65 25 6 SEL8
150 65 12 SLL2
MCC Type Product Number Digit SELT-L
150 65 6 SLL8
EVOLUTION SERIES E9000 E 150 100 100 25 12 SEP2
SEPT
150 100 100 25 6 SEP8
2 Select Feeder Disconnect Type
SFLT 250 65 65 25 12 SFLT
Select disconnect type. Transfer the product number digits to the SFPT 250 100 100 25 12 SFPT
boxes marked 2 in the product number line. SGL1C
150 100 65 65 24 GLI1
w-LT & INST
Type Voltage Product Number Digits
SGL1C
Circuit Breaker FB 150 100 65 65 24 LIG1
w-LT/INST & GF
Fusible Switch-R 208/240V FR SGL4C
400 100 65 65 24 GLI4
Fusible Switch-R 480/600V FS w-LT & INST

Fusible Switch-J 480/600V FJ SGL4C


400 100 65 65 24 LIG4
w-LT/INST & GF
SGL6C
600 100 65 65 24 GLI6
3 Select Amp Rating w-LT & INST
SGL6C
Select amp rating for either circuit breaker trip or Class R fuse. w-LT/INST & GF
600 100 65 65 24 LIG6

Transfer the product number digits to the boxes marked 3 in the 30 100 100 100 12 QMR3
product number line. 60 100 100 100 12 QMR6
FSW
Amps Product Number Digits Amps Product Number Digits 100 100 100 N/A 12 QMR1

15 015 110 110 200 100 1001 1001 24 QMR2


1 Unit height for 480V and 600V is 30.
20 020 125 125
30 030 150 150
40 040 175 175
5 Select System Voltage
50 050 200 200 Select system voltage. Transfer the product number digit to
60 060 225 225 the box marked 5 in the product number line.
70 070 250 250
Voltage Product Number Digit
80 080 400 400
480V 60 Hz A
90 090 600 600
208V 60 Hz B
100 100
240V 60 Hz C
575V 60 Hz D
380V 50 Hz E

Standard Feeder Unit Product Number


1 2 3 4 5

Door and Shelf Kit Door and Shelf Kit

6
6" EK06 6 EK30
30"
12" EK12 36" EK36
18" EK18 42" EK42
24" EK24 48" EK48

Note: Contact Factory for pricing.

Rev. 11/13 www.geindustrial.com BuyLog Catalog 15-9


Data subject to change
without notice
Page Updated 12 / 2016
Motor Control CentersLow Voltage Section 15
GE Fastrac ProgramMCC Units Quick Selection Guide
EVOLUTION SERIES E9000

OEM Extended Feeder Units for EVOLUTION SERIES E9000 Only


Short Circuit
Amp Rating KA Volts Unit Product
Rating Height Number
Device (Max.) 240 480 600 (Inches) Digits
18 SELT18
24 SELT24
SELT 150 65 65 25
30 SELT30
36 SELT36
18 SELL18
24 SELL24
SELT-L 150 65 65 65
30 SELL30
36 SELL36
18 SEPT18
24 SEPT24
SEPT 150 100 100 N/A
30 SEPT30
36 SEPT36
18 SFLT18
24 SFLT24
SFLT 250 65 65 25 30 SFLT30
36 SFLT36
42 SFLT42
18 SFPT18
24 SFPT24
SFPT 250 100 100 N/A 30 SFPT30
36 SFPT36
42 SFPT42
30 GLI430
SGL4B 400 100 65 65 36 GLI436
w-LT & Inst.
42 GLI442
30 LIG430
SGL4B 400 100 65 65 36 LIG436
w-LT/Inst. & GF
42 LIG442
30 GLI630
SGL6B 600 100 65 65 36 GLI636
w-LT & Inst.
42 GLI642
30 LIG630
SGL6B 600 100 65 65 36 LIG636
w-LT/Inst. & GF
42 LIG642

OEM Extended Feeder Unit Product Number


1 2 3 4 5

Note: Contact Factory for pricing.

15-10 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Motor Control CentersLow Voltage Section 15
GE Fastrac ProgramMCC Units Quick Selection Guide
EVOLUTION SERIES E9000

EVOLUTION SERIES E9000 MCC Sections 5 Bus Plating


This is for selection of one to three sections of 20" deep Select the bus plating. Transfer the product number digit to
EVOLUTION SERIES E9000 motor control centers without units. the box marked 5 in the product number line.
Each section will be shipped with blank doors. The typical section Bus Plating Product Number Digit
will have (3) 12", (1) 24" and (2) 6" doors and shelves. Tin T
For each of the following steps, find the optionshort circuit Silver S
rating, NEMA enclosure, etc.that meets the need. Transfer the
corresponding product number digit(s) to the corresponding prod- 6 Main Bus Rating
uct number box(es). When you have finished, you will have built a Select the main bus rating. Transfer the product number digit to
complete product number. the box marked 6 in the product number line.
Main Bus Rating Product Number Digit
1 Select Short Circuit Rating
600A 6
Select short circuit rating. Transfer the product number digit to 1200A 2
the box marked 1 in the product number line.
Short Circuit Rating Product Number Digit 7 Ground Bus
25 kAIC A Select the ground bus. Transfer the product number digit to
42 kAIC B the box marked 7 in the product number line.
65 kAIC C
Ground Bus Product Number Digit

2 NEMA Enclosure Type 300A 3


600A 6
Select the enclosure type. Transfer the product number digit
to the box marked 2 in the product number line. 8 Neutral Bus
NEMA Enclosure Type Product Number Digit Select the neutral bus. Transfer the product number digit to
1 Gasketed 1 the box marked 8 in the product number line.
12 2
Neutral Bus Product Number Digit
None 0
3 System Voltage
300A 3
Select the system voltage. Transfer the product number digit to 600A 6
the box marked 3 in the product number line.
System Voltage Product Number Digit
9 Horizontal Wire-Way
480V 60 Hz A Select the horizontal wire-way. Transfer the product number digit
208V 60 Hz B to the box marked 9 in the product number line.
240V 60 Hz C Horizontal Wire-Way Product Number Digit
575V 60 Hz D 12" Top-6" Bottom T
380V 50 Hz E 12" Top-12" Bottom B

4 System Wires 10 Main Location


Select the system wires. Transfer the product number digit to Select the location of the main. Transfer the product number digit
the box marked 4 in the product number line. to the box marked 10 in the product number line.
System Wires Product Number Digit Main Location Product Number Digit
3W 3 Top Left TL
4 W-Neutral 4 Bottom Left BL
Top Right TR
Bottom Right BR

Note: Contact Factory for pricing.

Rev. 11/13 www.geindustrial.com BuyLog Catalog 15-11


Data subject to change
without notice
Motor Control CentersLow Voltage Section 15
GE Fastrac ProgramMCC Units Quick Selection Guide
EVOLUTION SERIES E9000

11 Main Type 12 Main Circuit Breaker Trip or Main Switch Fuse


Select the type of main. Transfer the product number digits to the Select main circuit breaker trip or main switch fuse. Transfer
boxes marked 11 in the product number line. the product number digit to the box marked 12 in the product
Main Type Product Number Digits number line.
600A Splice 6S Main CB or
Main Switch Fuse Product Number Digit
1200A Splice 2S
No Fuse 0
600A MLO 6L
300A 3
1200A MLO Bottom 2L
400A 4
1200A MLO Top 2L
600A 6
600A CB 6C
800A 8
1200A CB 2C
1000A 1
600A Switch 6F
1200A 2

13 Number of Vertical Sections with Common Main Bus


Select the number of sections with common main bus. Transfer
the product number digit to the box marked 13 in the product
number line.
Number of Sections Product Number Digit
One 1
Two 2
Three 3

1 2 3 4 5 6 7 8 9 10 11 12 13
Section
Product
Number L E F

Note: Contact Factory for pricing.

15-12 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Motor Control CentersLow Voltage Section 15
Frequently Requested Motor Control Center Renewal Parts
EVOLUTION SERIES E9000
Renewal Parts
Part Description Product Number
Size 1 Standard O/L 9000RSG1
Size 1 Electronic O/L 9000RSG2
O/L Reset Assembly Size 2,5 Standard O/L 9000RSG3
Size 2,5 Electronic O/L 9000RSG4
Size 3,4 Standard O/L 9000RSG5
Size 3,4 Electronic O/L 9000RSG6
Door Hinges Door Hinges 190B1013P1
Power Pull Apart Terminal Block 50A 190B1691G1
Terminal Block Din Rail Assembly 18 Points Max 190B2070G6
Terminal Blocks Terminal Block Din Rail Assembly 18 Points Max w/ TB 190B2070G12
Control TB 30A Male and Female 190B1692G1
Wireway Covers Top 12" with hinges 110C1440G1
Wireway Covers
Wireway Covers Top 18" with hinges 110C1440G2
CPT 150VA, 480/120 Size 1 and 2 w/o Fuse Block 9T58K0504G37
Control Power Transformers CPT 300VA, 480/120 Size 1 and 2 With Fuse Block 9T58K0507G38
CPT 100VA, 480/120 Size 1 1/2X, Size 5 W/O Fuse Block MIC#B100-2989-5
Standard Shelf 110C1059P1
Shelf Grounding Bracket 270A1343G1
Bus Shutter Assembly 110C1783G1
Miscellaneous
Vertical Bus Stab Covers 190B1215P1
Wireway Knock Out Panel 190B1014P1
Shelf Support - 72" High 110C1010G11
E and F Frame CB Vertical Handle Only 190B1704G1
Circuit Breaker/Starter Handles
E and F Frame CB Horizontal Handle Only 190B1704G2
6" EK06
12" EK12
18" EK18
Filler Kits 24" EK24
(Includes Shelf and Grounding Bracket) 30" EK30
36" EK36
42" EK42
48" EK48
Rear Cover Only 190B1007P9
Rear Hinge Door Top Only 110C1466G9
Rear Doors Only
Rear Hinge Door Bottom Only 110C1466G21
Rear Hinge Mounting Bracket (2 Per Section) 110C1464P1
6" High 110C1163G1
12" High 110C1163G2
18" High 110C1163G3
24" High 110C1163G4
30" High 110C1163G5
36" High 110C1163G6
Wire Trough Doors (4")
42" High 110C1163G7
48" High 110C1163G8
54" High 110C1163G9
60" High 110C1163G10
66" High 110C1163G11
72" High 110C1163G12
Muffin Fan 120V Only MUFFINFANG1
Tarzan Fan Only RMC#020169
Cooling Fans
Case Fan Assembly 110C1556G1
N3R Fan Assemblies Refer to Factory
6" 110C1240KKG1
12" 110C1240KKG2
18" 110C1240KKG3
24" 110C1240KKG4
Blank Unit Door
30" 110C1240KKG5
36" 110C1240KKG6
42" 110C1240KKG7
48" 110C1240KKG8
6 Unit Device Plate Only 110C1039P100
Pilot Device Bracket 3 Unit Device Plate Only 110C1089P100
Bracket 190B1662P1
600Amp Bus 110C1735G1SM
Splice Kits 800Amp Bus 110C1735G4SM
(Evolution to Evolution N1, N12 Only) 1200Amp Bus 110C1735G7SM
(Standard Tin Only) 2000Amp Bus 110C1735G12SM
2500Amp Bus 110C1735G13SM
50Amp CSC#A50QS50
60Amp CSC#A50QS60
80Amp CSC#A50QS80
Optional Semiconductor
100Amp CSC#A50QS100
Soft Start Fuses
200Amp CSC#A50QS200
225Amp CSC#A50QS225
350Amp CSC#A50QS350

Motor Control Centers Parts Publications List


Model Description Number
EVOLUTION SERIES E9000 Installation GEH 40472

Note: Contact Factory for pricing.

Rev. 11/13 www.geindustrial.com BuyLog Catalog 15-13


Data subject to change
without notice
Motor Control CentersLow Voltage Section 15
GE Fastrac ProgramMCC Units Quick Selection Guide
CR8000

This Quick Selection Guide covers Control Center starters and 2 Select Starter Type and Size
feeders, including full and reduced voltage, reversing and non- Find the starter type required. Transfer the product number digits
reversing, two-speed single and dual winding starters, in sizes to the boxes marked 2 in the product number line.
1-5. For other units, see the Engineered Products Catalog,
Starter Type Size Product Number Digits
Section 10.
1 A1
Motor Control Starter Units 2 A2
FVNR
For each of the following steps, find the optionMCC type, starter 3 A3

type, size, disconnect, control power, pilot lights, etc. that meets 4 A4

the need. Transfer the corresponding product number digit(s) to 1 B1

the product number box(es). 2 B2


FVR
3 B3
When you have finished, you will have built a complete product 4 B4
number. 1 C1

1 Select Motor Control Center Type 2 C2


2S1W
3 C3
Select motor control center type. Transfer the product number 4 C4
digits to the box marked 1 in the product number line. 1 D1
MCC Type Product Number Digit 2 D2
2S2W
CR8000 M 3 D3

S 4 D4
3 E3
RVNR
4 E4

All Fastrac units have the following as standard:


A. NEMA 12 gasketing
B. Isolated N.O. overload alarm contact (not wired to TB)
C. Auxiliary. contacts wired to the TB as noted below:
FVNR and RVNR Starters(1) N.O. (1) N.C.
FVR and 2S Starters(1) N.O. per contactor

Note: Contact Factory for pricing.

15-14 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Motor Control CentersLow Voltage Section 15
GE Fastrac ProgramMCC Units Quick Selection Guide
CR8000

3 Select Starter Disconnect 4 Select Control Power


Use the first table to identify desired disconnect device. Standard control power transformer (CPT) ratings are adequate to
(Note that these are for basic applications; see publication handle the starter-coil current and three pilot lights. If additional
GET-6728 for more information.) Then, from the second table burdens are expected, larger transformers should be specified
select starter disconnect. Transfer the product number digit to from among those shown in the first table below. From the
the box marked 3 in the product number line. second table below, select the control power desired. Transfer
Short Circuit Rating the product number digit to the box marked 4 in the product
Starter Mag Only Thermal Mag
Size Circuit Breaker Circuit Breaker 230V 460V 575V number line.
Spectra - 65k Spectra - 65k 65 65 25 Product number digit 1 is for 100VA CPT.
1, 2, 3
Spectra -100k Spectra - 100k 100 100
Starter Type and Size CPT Std. VA Oversize VA
Spectra - 65k Spectra - 65k 65 65 25 All Size 1 60 150
4
Spectra - 100k Spectra - 100k 100 100
All Size 2 150
Spectra - 65K Spectra - 65K 65 65 65 All Size 3 300
5
Spectra - 100K Spectra - 100K 100 100 100 All Size 4 300

All Size 5 100

Product Starter Size


Disconnect Number
Device Digit 1 2 3 4 5 Control Product Starter Size
Power Number
FSW-R F (120 Vac)4 Digit 1 2 3 4 5
FSW-J2 R Std. CPT 1
Spectra 65 Oversize 2
U
Mag Only1
Line-to-Line 4
Spectra 100 V
Mag Only Common/
Separate 5
Spectra 65 Source
W
Thermal Mag1
Spectra 100 X
Thermal Mag
1 25KAIC @ 575V.
2 J time delay.

Note: Contact Factory for pricing.

Rev. 11/13 www.geindustrial.com BuyLog Catalog 15-15


Data subject to change
without notice
Motor Control CentersLow Voltage Section 15
GE Fastrac ProgramMCC Units Quick Selection Guide
CR8000

5 Select Pilot Devices 5 Select Pilot Devices (continued)


Select pilot devices desired by starter
I type. See Pilot Devices Starter Incandescent LED
Type Pilot Device Product Number Digits Product Number Digits
table below and note the lamp type as either Incandescent
or LED. Transfer the product number digits to the boxes NONE - Blank Pilot Device
NN -
Bracket Provided
marked 5 in the product number line.
RED/AMBER LGT STD EF SF
Starter Incandescent LED S RED/AMBER LGT PTT ES SS
Type Pilot Device Product Number Digits Product Number Digits R/A/G LGT STD EG SG
NONE - Blank Pilot Device R/A/G LGT PTT ET ST
NN* -
Bracket Provided
FAST/SLOW/STOP PB EN -
RED LGT STD AE* OE* R
FAST/SLOW/STOP PB R/A LGT STD EB SB
RED LGT PUSH-TO-TEST (PTT) AF OF 2S1W & FAST/SLOW/STOP PB R/A LGT PTT EP SP
2S2W
RED/GREEN LGT STD AS* OS* FAST/SLOW/STOP PB R/A/G LGT STD EC SC
RED/GREEN LGT PTT AT OT FAST/SLOW/STOP PB R/A/G LGT PTT EQ SQ
HAND/OFF/AUTO (H/O/A) SW. AN* - FAST/SLOW/OFF/AUTO (F/S/O/A) SW FN -
H/O/A SW. RED LGT STD AB* OB* F/S/O/A SW R/A LGT STD FB TB
H/O/A SW. RED LGT PTT AP OP F/S/O/A SW R/A LGT PTT FP TP
H/O/A SW. R/G LGT STD AC* OC* F/S/O/A SW R/A/G LGT STD FC TC
H/O/A SW. R/G LGT PTT AQ OQ F/S/O/A SW R/A/G LGT PTT FQ TQ
FVNR & H/O/A SW. STOP/START PB RED LGT STD AD OD
RVAT & 6 Select Overload Relay
RVSS H/O/A SW. STOP/START PB RED LGT PTT AR OR
STOP/START PB BN* - Select overload relay type. Transfer the product number digits to
STOP/START PB RED LGT STD BB* PB*
the box marked 6 in the product number line.
STOP/START PB RED LGT PTT BP PP
STOP/START PB R/G LGT STD BC PC Relay Type Product Number Digit
STOP/START PB R/G LGT PTT BQ PQ Standard 1
OFF/ON SW. GN* - Ambient Compensated 2*
OFF/ON SW. RED LGT STD GB* UB* Solid State 3
OFF/ON SW. RED LGT PTT GP UP
OFF/ON SW. R/G LGT STD GC* UC* 7 Select Control Terminal Board
OFF/ON SW. R/G LGT PTT GQ UQ
Select control disconnect terminal board. Transfer the product
NONE - Blank Pilot Device
Bracket Provided
NN - number digits to the box marked 7 in the product number line.
RED/GREEN LGT STD CE QE Control Disconnect Terminal Board Product Number Digit
RED/GREEN LGT PTT CR QR Standard High-Density H
RED/AMBER LGT STD CF QF
RED/AMBER LGT PTT CS QS
R/A/G LGT STD CG QG 8 Select Horsepower
R/A/G LGT PTT CT QT Select horsepower. Transfer the product number digits to the
FWD/REV/STOP PB CN -
boxes marked 8 in the product number line. Note that some
FVR FWD/REV/STOP PB R/A LGT STD CB QB
product number digits consist of a decimal point.
FWD/REV/STOP PB R/A LGT PTT CP QP
FWD/REV/STOP PB R/G/A LGT STD CC QC Horsepower Product Number Digits Horsepower Product Number Digits
FWD/REV/STOP PB R/G/A LGT PTT CQ QQ 1/4 .25 15 015
FWD/OFF/REV SW DN - 1/3 .33 20 020
FWD/OFF/REV SW RED LGT STD DB RB 3/8 .38 25 025
FWD/OFF/REV SW RED LGT PTT DP RP
1/2 .50 30 030
FWD/OFF/REV SW R/G LGT STD DC RC
3/4 .75 40 040
FWD/OFF/REV SW R/G LGT PTT DQ RQ
1 001 50 050
1 1/2 1.5 60 060
2 002 75 075
3 003 100 100
5 005 125 125
7 1/2 7.5 150 150
10 010 200 200

Note: Contact Factory for pricing.

15-16 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Motor Control CentersLow Voltage Section 15
GE Fastrac ProgramMCC Units Quick Selection Guide
CR8000

9 Select System Voltage 10 OEM Fastrac Units


Select system voltage. Transfer the product number digit to the Fastrac units designed for OEM use are engineered and built with
box marked 9 in the product number line. the same components and layout as the standard Fastrac units.
Power wiring is provided: however, to allow the maximum flexibil-
Voltage Product Number Digit
ity for OEM users, no control wiring is provided.
480V 60 Hz A
Product numbers are the same as the standard Fastrac units
208V 60 Hz B
with the addition of two additional suffix letters, XX.
240V 60 Hz C
Example:
575V 60 Hz D
Standard Fastrac Unit MA1U1AB1H010A
380V 50 Hz E
OEM Fastrac Unit MA1U1AB1H010AXX

1 2 3 4 5 6 7 8 9 10
Starter
Product
Number
l

Note: Contact Factory for pricing.

Rev. 11/13 www.geindustrial.com BuyLog Catalog 15-17


Data subject to change
without notice
Page Updated 12 / 2016
Motor Control CentersLow Voltage Section 15
GE Fastrac ProgramMCC Units Quick Selection Guide
CR8000

Motor Control Feeder Units 4 Select Feeder Device


For each of the following steps, find the optionMCC type, Select feeder device from one of the following two tables. Transfer
disconnect type, amp rating, feeder devicesthat meets the need. the product number digits to the boxes marked 4 in the product
Transfer the corresponding product number digits to the product number line for either the standard or OEM extended feeder unit.
number boxes for either the standard or OEM extended feeder
unit. When you have finished, you will have built a complete Standard Feeder Units
product number. Short Circuit
Amp Rating KA Volts Unit Product
1 Select Motor Control Center Type Rating Height Number
Device (Max.) 240 480 600 (Inches) Digits
Select motor control center type. Transfer the product number 100 65 65 25 6 SEL6
digit to the box marked 1 in the product number line. SELT 1 100 65 65 25 12 SEL2
MCC Type Product Number Digit 150 100 100 25 18 SEL8
CR8000 M 100 65 6 SLL6
SELT-L
S 100 65 12 SLL2
2 Select Feeder Disconnect Type 100 100 100 25 6 SEP6
Select disconnect type. Transfer the product number digits to the SEPT 1 100 100 100 25 12 SEP2

boxes marked 2 in the product number line. 150 100 100 25 18 SEP8
SFLT 225 65 65 25 18 SFLT
Type Voltage Product Number Digits
SFPT 225 100 100 25 18 SFPT
Circuit Breaker FB
30 100 100 100 6 QM36
Fusible Switch-R 208/240V FR
30 100 100 100 12 QMR3
Fusible Switch-R 480/600V FS
60 100 100 100 6 QM66
Fusible Switch-J 480/600V FJ FSW
60 100 100 100 12 QMR6
100 100 100 25 12 QMR1
3 Select Amp Rating
200 100 100 100 24 QMR2
Select amp rating for either circuit breaker trip or Class R fuse. 1 150A unit is 18" high.
Transfer the product number digits to the boxes marked 3 in the
product number line.
5 Select System Voltage
Amps Product Number Digits Amps Product Number Digits Select system voltage. Transfer the product number digit to
15 015 110 110 the box marked 5 in the product number line.
20 020 125 125
Voltage Product Number Digit
30 030 150 150
480V 60 Hz A
40 040 175 175
208V 60 Hz B
50 050 200 200
240V 60 Hz C
60 060 225 225
575V 60 Hz D
70 070 250 250
380V 50 Hz E
80 080 400 400
90 090 600 600 Standard Feeder Unit Product Number
100 100

1 2 3 4 5

Note: Contact Factory for pricing.

15-18 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Motor Control CentersLow Voltage Section 15
Frequently Requested Motor Control Center Renewal Parts
7700-Line, 8000-Line and Spectra Series

Renewal Parts
MCC Type
Parts Description 7700 8000 Spectra Product Number
Shelf-Standard X X X 68J210383BBXXXXXXY
Shelf Support X X X 117B5044P2
Vertical Bus Parts
Bus Shutter Assembly X X X 204B4153BVG1
Door Latch X X X 169C6386DMG2
Muffin Fan X X X 272A5509SDP1
Cooling Fans
Tarzan Fan X X X RMC#020169
6" x 20" X X X 204B4127G19
Wireway Covers 12" x 20" X X X 204B4127G20
18" x 20" X X X 204B4127G21
Size 1 All X X 204B4142BDG1
Size 1 All X 116C8961G1
Size 2 All X 116C8961G2
Size 2 FVNR X X 204B4142BDG2
Size 2 FVR - 2 Speed X X 204B4142BDG3
O/L Reset Assy Size 3 & 4 All X 116C8961G32
Size 3 & 4 FVNR-FVR-2 Speed X X 204B4142BDG42
Size 3 & 4 RVNR X X 204B4142BDG52
Size 5 All X 116C8961G5
Size 5 All X X 204B4142BDG6
60VA (With Fuse Block) X X X 302A3600YDP201
150VA (With Fuse Block) X X X 302A3600YDP204
Control Power Transformer
300VA (With Fuse Block) X X X 302A3600YDP207
300VA (No Fuse Block) X X X 302A3600YDP7
Male - 3 Point X X 75B132504G701
Standard TB
Female - 3 Point X X 204B4153APG1
Male - 3 Point X X 75B132504G701
Female - Size 1 & 2 - 3 Point (w/lugs) X X 204B4153APG2
Power TB
Size 3 - 3 Point X X 204B4050WDG5
Size 4 - 3 Point X X 204B4050WDG1
High Density TB 6 Point-Control X X CR151KPP56F
6" High X 273A7764G61
12" High X 273A7764G121
18" High X 273A7764G181
24" High X 273A7764G241
Filler Kit - 7700 Line
30" High X 273A7764G301
36" High X 273A7764G361
42" High X 273A7764G421
48" High X 273A7764G481
6" High X 204B4145AMG11
12" High X 204B4145AMG21
18" High X 204B4145AMG31
24" High X 204B4145AMG41
Filler Kit - 8000 Line
30" High X 204B4145AMG51
36" High X 204B4145AMG61
42" High X 204B4145AMG71
48" High X 204B4145AMG81
6" High X 68J210397DAXX06XXB
12" High X 68J210397DAXX12XXB
18" High X 68J210397DAXX18XXB
24" High X 68J210397DAXX24XXB
Blank Spectra Door
30" High X 68J210397DAXX30XXB
36" High X 68J210397DAXX36XXB
42" High X 68J210397DAXX42XXB
48" High X 68J210397DAXX48XXB
6" High X 272A5650BVP9
12" High X 272A5650BVP10
18" High X 272A5650BVP11
24" High X 272A5650BVP12
Spectra Fill Strip
30" High X 272A5650BVP13
36" High X 272A5650BVP14
42" High X 272A5650BVP15
48" High X 272A5650BVP16
Left X X 117B5027P2
Right X X 117B5027P3
Door Hinges
Spectra Hinge X 204B4145FZP1
Spectra Hinge Pin X 273A7728TLP1
20" Wide X X X 68J210375DB2090XXB
Rear Doors
24" Wide X X X 68J210375DB2490XXB
20" Wide X X X 68J120323LE0102AAB3
Rear Covers
24" Wide X X X 68J120323XA0102AAB3
1Includes blank door, shelf, shelf support and hinged filler strip.
2O/L types. Refer to factory
3Flat covers for 13" MCC
Note: Contact Factory for pricing.

Rev. 11/13 www.geindustrial.com BuyLog Catalog 15-19


Data subject to change
without notice
Motor Control CentersLow Voltage Section 15
Frequently Requested Motor Control Center Renewal Parts
7700-Line, 8000-Line and Spectra Series

Renewal Parts (continued)


MCC Type
Parts Description 7700 8000 Spectra Product Number
6" High X X 68J210375CB2006XXB4
12" High X X 68J210375CB2012XXB4
24" High X X 68J210375CB2024XXB4
30" High X X 68J210375CB2030XXB4
36" High X X 68J210375CB2036XXB4
42" High X X 68J210375CB2042XXB4
48" High X X 68J210375CB2048XXB4
54" High X X 68J210375CB2054XXB4
60" High X X 68J210375CB2060XXB4
66" High X X 68J210375CB2066XXB4
72" High X X 68J210375CB2072XXB4
18" High X 68J210375SCB2018XXB4
Wire Trough Doors
6" High X 68J210397AC2006XXB4
12" High X 68J210397AC2012XXB4
18" High X 68J210397AC2018XXB4
24" High X 68J210397AC2024XXB4
30" High X 68J210397AC2030XXB4
36" High X 68J210397AC2036XXB4
42" High X 68J210397AC2042XXB4
48" High X 68J210397AC2048XXB4
54" High X 68J210397AC2054XXB4
60" High X 68J210397AC2060XXB4
66" High X 68J210397AC2066XXB4
72" High X 68J210397AC2072XXB4
40 Amp Other CSC#A50P40
60 Amp Other CSC#A50P60
100 Amp Other CSC#A50P100
Semiconductor Fuses for Drives
175 Amp Other CSC#A50P175
200 Amp Other CSC#A50P200
300 Amp Other CSC#A50P300
1000 Amp Other CSC#A50P1000
1200 Amp Other CSC#A50P1200
1600 Amp Other CSC#A50P1600
60 Amp Other CSC#A50QS60
100 Amp Other CSC#A50QS100
150 Amp Other CSC#A50QS150
Semiconductor Fuses for Soft Starters
175 Amp Other CSC#A50QS175
225 Amp Other CSC#A50QS225
250 Amp Other CSC#A50QS250
300 Amp Other CSC#A50QS300
350 Amp Other CSC#A50QS350
600 Amp Other CSC#A50QS600
Single Other ACT#4380-2000
Signal Conditioners
Double Other ACT#4390
General Other Refer to Factory
CR7 Other Refer to Factory
Relays
ITI Other Refer to Factory
MCRA Other Refer to Factory
4Product Numbers shown are for 7700 and 8000 line 20" wide sections. If wider than 20" substitute section width into product number eg/24"W x 6"H use
#68J210375CB2406XXB.

Motor Control Center Parts Publications List


Model Description Number
Shelf-Standard GEH 2614
7700 Line
Renewal Parts GEH 4629
Installation GEH 4961
8800 Line
Renewal Parts GEH 4630

Note: Contact Factory for pricing.

15-20 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Motor Control CentersLow Voltage Section 15
Frequently Requested Motor Control Center Renewal Parts
7700-Line, 8000-Line and Spectra Series

Buckets and Associated Parts Individual Parts

Bucket Type Individual Part Type NEMA Size Height (in.) MCC Type Product Number
1 12" Other 204B4054G10
Disconnect
2 12" Other 204B4054G26
3 30" Other 204B4054G62
Fused Switch N/A
4 42" Other 204B4056G15
1 12" Other 8000L8G2
Stab Harness
2 12" Other 8000L8G8
4 30" Spectra 8000L4G47
Stab Harness 3 24" Spectra 8000L4G48
N/A N/A Spectra 8000L8G21
1 12" Spectra CR306C002ACET
N/A N/A Spectra CR306D002LVH
Starter
3 24" Spectra CR306E002LVH
4 30" Spectra CR306F002LVH
1 12" Spectra CSC#ATMR1/2
CPT Fuse Primary 2 12" Spectra CSC#ATMR1
4 30" Spectra CSC#ATMR2
Spectra Circuit Breaker 2 12" Spectra CSC#TR1-6/10R
CPT Fuse Secondary 4 30" Spectra CSC#TR3-2/10R
1 12" Spectra CSC#TR6/10R
1 12" Spectra SELA36AI0007
2 12" Spectra SELA36AI0030
Disconnect
3 24" Spectra SELA36AI0100
4 30" Spectra SFLA36AI0250
3 24" Spectra SRPE100A70
2 12" Spectra SRPE30A25
Rating Plug
1 12" Spectra SRPE7A3
4 30" Spectra SRPF250A150

Buckets and Associated Parts Complete Bucket

Bucket Type NEMA Size Horsepower Height (in.) MCC Type Product Number
1/4 12" Other MA1F1AB2J.25A
1/3 12" Other MA1F1AB2J.33A
3/8 12" Other MA1F1AB2J.38A
1/2 12" Other MA1F1AB2J.50A
3/4 12" Other MA1F1AB2J.75A
1 12" Other MA1F1AB2J001A
1
2 12" Other MA1F1AB2J002A
3 12" Other MA1F1AB2J003A
5 12" Other MA1F1AB2J005A
10 12" Other MA1F1AB2J010A
Fused Switch 1 1/2 12" Other MA1F1AB2J1.5A
7 1/2 12" Other MA1F1AB2J7.5A
15 12" Other MA2F1AB2J015A
2 20 12" Other MA2F1AB2J020A
25 12" Other MA2F1AB2J025A
30 30" Other MA3F1AB2J030A
3 40 30" Other MA3F1AB2J040A
50 30" Other MA3F1AB2J050A
60 42" Other MA4F1AB2J060A
4 75 42" Other MA4F1AB2J075A
100 42" Other MA4F1AB2J100A
1/4 12" Spectra MA1U1AB2J.25A
1/3 12" Spectra MA1U1AB2J.33A
3/8 12" Spectra MA1U1AB2J.38A
1/2 12" Spectra MA1U1AB2J.50A
3/4 12" Spectra MA1U1AB2J.75A
1 12" Spectra MA1U1AB2J001A
1
2 12" Spectra MA1U1AB2J002A
3 12" Spectra MA1U1AB2J003A
5 12" Spectra MA1U1AB2J005A
10 12" Spectra MA1U1AB2J010A
Spectra Circuit Breaker 1 1/2 12" Spectra MA1U1AB2J1.5A
7 1/2 12" Spectra MA1U1AB2J7.5A
15 12" Spectra MA2U1AB2J015A
2 20 12" Spectra MA2U1AB2J020A
25 12" Spectra MA2U1AB2J025A
30 24" Spectra MA3U1AB2J030A
3 40 24" Spectra MA3U1AB2J040A
50 24" Spectra MA3U1AB2J050A
60 30" Spectra MA4U1AB2J060A
4 75 30" Spectra MA4U1AB2J075A
100 30" Spectra MA4U1AB2J100A

Note: Contact Factory for pricing.

Rev. 11/13 www.geindustrial.com BuyLog Catalog 15-21


Data subject to change
without notice
Motor Control CentersLow Voltage Section 15

NOTES:

15-22 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Switchgear Low Voltage Section 16

Introduction.................................................................................16-1
AKD-10 Low-Voltage Switchgear ............................................16-3
AKD-20 Low-Voltage Switchgear ............................................16-3
Arc Vault Arc Flash Protection System ................................16-4

Low Voltage Switchgear Key Switchgear Features


GE low-voltage switchgear is heavy-duty equipment built to ANSI Full tin-plated copper bus
Standards. GE switchgear is designed to have more margin within Optional insulated/isolated bus bar systemprotects against
its ratings and to provide maximum continuity of service for those accidental contact by people or foreign objects and inhibits the
applications subject to severe duty such as repetitive switching spread of any arcing faults.
encountered with motor starting, power factor correction, Breaker compartment doors without ventilating slots
demand control, and load shedding, etc. A major factor True closed-door draw-outadded protection for operator
contributing to this extended continuity of service is the Instrument panel for breaker control circuitrypermits several
availability of renewal parts complete with detailed maintenance maintenance functions without subjecting operators to ener-
instructions and original equipment documentation. From a gized primary circuits of an open breaker compartment door
coordination standpoint, Air circuit breakers can provide full Optional shutters over primary disconnectsprovides
selectivity with each other and with other protective devices. personnel protection from energized disconnects
The bus is thermally rated; i.e. based upon temperature rise, as Modular constructionfor greater installation flexibility
opposed to switchboards where the bus may be sized on a
current density basis.
Switchgear also houses instrumentation and other auxiliary
circuit protective devices. It is available in single or multiple
source configurations and applied as a power distribution unit or
as part of a unit substation in indoor or outdoor construction.

Rev. 11/13 www.geindustrial.com BuyLog Catalog 16-1


Data subject to change
without notice
Switchgear Low Voltage Section 16

CSI Specifications
Low Voltage Metal Enclosed
16400 Low Voltage Switchgear
26 23 00 Low Voltage Switchgear

Low Voltage Switchgear One-Line

Medium Voltage

Secondary Substation Paralleling Switchgear


Transformers G G

M Power Meters

Ground Fault GF TVSS


Detectors

Circuit
Breakers
High Pressure
Contact Switches
Switchgear and
Switchboards
Automatic Transfer Switch

Busway Loadcenters and


Metering Modules
Motor Control Centers
and Drives UPS

1 2 4
FVNR FVNR FVNR Reactor

VFD
Distribution
Y
M M M M Transformers
Capacitors and Panelboards and
Motors Harmonics Filters Lighting Panels

Lighting Controls

Voltage
Regulators
Safety
Ballasts M Switches

Luminaires
and Lamps

Power
Ethernet Monitoring
Software
Network Design
and Equipment
Hub

16-2 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Switchgear Low Voltage Section 16
AKD-10 and AKD-20
For pricing and application assistance,
contact your local GE sales office.

GE type AKD-10 low-voltage switchgear consists of WavePro


power circuit breakers combined with the field-proven switchgear
design features needed to meet todays exacting requirements
for safety, reliability, maintainability, flexibility, convenience,
economy and continuity of service. Integral to the WavePro
low-voltage power circuit breaker is the Power+, enhanced
MicroVersaTrip Plus or MicroVersaTrip PM solid-state, digital
trip unit. The optional POWER LEADER Power Management
System is available for applications requiring a completely
integrated system including overcurrent protection, protective
relaying and system monitoring. AKD-10 switchgear and WavePro
circuit breakers meet or exceed industry standards including UL
1066 and 1558; CSA C22.2; NEMA SG-3 and SG-5; ANSI-C37.13
and C37.20.1.

WavePro and EntelliGuard


Low Voltage Power Circuit Breakers POWER LEADER Power Management System
Time provenfor trouble free performance A MicroVersaTrip PM trip unit on each breaker for overload,
Five cycle stored energy closing short-circuit and ground fault protection, with true rms sensing
6 frame sizes 800-5000 ampsfor application flexibility and an LCD for local metering.
Interrupting ratings: 30kA-200kA Trip unit mounted in the breaker escutcheon, providing
Fully maintainableto assure operational readiness convenient out front trip unit information on the LCD.
MicroVersaTrip solid-state protection trip unit with LCD A Modbus Monitor mounted on the switchgear with a
increased flexibility and accuracy with true rms sensing for display screen and keypad to display power systems data.
standard (s) and optional (o) time-current adjustments: A shielded, twisted pair communication bus that carries
Adjustable current setting (s) information between the POWER LEADER Monitor
Adjustable long-time delay (s) and breakers.
Phase selectable digital rms ammeter (s) A port for remote communication. All information can be
Adjustable instantaneous pick-up (s) transmitted to a host computer for metering, energy monitoring,
Adjustable ground fault pick-up and adjustable ground fault load analysis and other functions using POWER LEADER Power
delay with selectable I2t curve (o) Management Control System software.
Adjustable short-time pick-up and adjustable short-time
delay with selectable I2t curve (o)
Zone selective interlockingfor improved selectivity on AKD-20 Low-Voltage Switchgear
both short-time and ground-fault or ground-fault only (o) For pricing and application assistance, contact your local GE
Defeatable GF (o) sales office.
Switchable INST/ST and GF (o) GE type AKD-20 low-voltage switchgear consists of EntelliGuard
Integrally fused breakersfor high fault-current applications G power circuit breakers and state-of-the art EntelliGuard TU
Rating plugs for added flexibility digital trip unit that together provide enhanced protection,
Power+ Trip unit with true rms sensing and rotary selection of endurance and safety. The key features of the AKD-20 are the
pick-up and delay settings: tried and true construction of the AKD family heritage, common
Adjustable long-time pick-up and delay (s) transitions to older versions of AKD equipment, true closed door
Adjustable instantaneous pick-up (s) racking with remote racking devices, non vented circuit breaker
Adjustable short-time pick-up and delay with I2t in or out (o) panels, insulated and isolated bus construction and more. The
Adjustable ground fault pick-up and delay with l2t in or out (o) product is fully rated to UL 1066 and 1558; CSA C22.2; NEMA SG-3
Defeatable ground fault (o) and SG-5; ANSI C37.13 and C37.20.1; Seismic ratings to IBC-2003
Target module with LED trip indicators (o) and IEEE-693-1997.
Ground fault function contained within the rating plug

Instructions/Maintenance
Low Voltage Switchgear
AKD-10 Application Guide DET-196
WAVEPRO Low Voltage Power Circuit Breaker
Application Guide DET-167
User Publication Summary DEE-194

Rev. 11/13 www.geindustrial.com BuyLog Catalog 16-3


Data subject to change
without notice
Arc Vault Arc Flash Protection System Section 16

Stop Arc Flash in Its Tracks With the Fastest Arc Flash
Containment Technology Available.
GEs innovative Arc Vault takes a different approach. It doesnt
exhaust the arc flash; it extinguishes it. Arc Vault can stop an
arcing fault in less than eight milliseconds, a fraction of the time
that traditional systems need to stop a flash.

When it comes to arc flash protection, the faster a flash is


eliminated, the less destructive energy it generates. Arc Vault
cuts the energy released by the flash, reducing the potential for
serious injury and minimizing stress on transformers, circuit
breakers, and other equipment. In many cases, youll be
operational within a working day. And Arc Vault protects your
people and your equipment whether the cabinet doors are open
or closed.

A product of GEs Global Research organization, Arc Vault is


typical of the kind of breakthrough products youve come to
expect from GE. It is innovative, reflecting our industry leadership
in arc flash protection, yet reliable. Over the last five years,
weve subjected the Arc Vault to GEs rigorous development
and testing process to make sure it performs under the most
demanding conditions.

GE Arc Vault advantages:


It can stop an arc fault in just 8 milliseconds and reduces
incident energy to less than 1.2 cal/cm2.
It helps reduce work-related injuries even when panel doors are
open during routine maintenance.*
It decreases stress on equipment due to an arc flash, cutting
downtime to as little as a single day.
It reduces energy released by 63% or more compared to a
bolted fault that would occur with a crow bar system.
It eliminates the need to install exhaust chimneys or plenums.
It can be retrofitted on most existing low-voltage equipment.
When activated, Arc Vault continuously monitors current and
voltage to identify an arc flash.
When an arc flash occurs, the arc is diverted by creating a
secondary arc fault, not a bolted fault as in crow bar systems.
At the same time, the system opens an upstream circuit breaker,
eliminating the fault condition and de-energizing the system.

Ready to Retrofit and Integrate


Arc Vault provides superior arc flash protection virtually
anywhere theres low-voltage equipment. You can scale the
suppression for such variables as the number of sources, and
main-tie-main configurations.

Reference Publications
Arc Vault Application Guide DEH-41484
Arc Vault Installation Operation and Maintenance Manual DEH-41483

*Under normal conditions, the doors should remain closed.

16-4 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Entellisys 5.0 Low-Voltage Switchgear Section 17

Entellisys 5.0 is the sensible choice to save you money over the Entellisys is becoming the preferred solution in critical applica-
lifetime of your system. tions such as data centers, hospitals, petro/chem facilities and
airports around the world. State-of-the-art protection, monitoring
Entellisys Low-Voltage Switchgear is the first system to provide and control make it the intelligent choice to provide reliable power
the power of knowledge about the entire switchgear lineup. distribution now and in the future.

This power can be used: Contact your account manager and request a financial savings
by the engineer to improve protection, report, customized for your application.
by the installing contractor to shorten installation time,
by the operator to stay out of the arc flash zone, Layout and sizing .......................................................................17-2
by the maintenance personnel to save maintenance time
and money, and
by the owner to adapt the equipment to the dynamic needs
of the facility.

Entellisys helps to reduce costs, shorten schedules, and increase


reliability throughout the process of designing, installing, main-
taining, and owning your low-voltage power distribution
switchgear.

Rev. 11/13 www.geindustrial.com BuyLog Catalog 17-1


Data subject to change
without notice
Entellisys 5.0 Low-Voltage Switchgear Section 17
Layout and Sizing

Entellisys indoor low voltage switchgear height is 92" (97" over 6. Front busway connections to a circuit breaker require a blank
the top wiring trough and 103.5" over the optional breaker hoist). compartment above the breaker for busway above or a blank
The available breaker stacking space is 84". compartment below the breaker for busway below.
7. Use of fused breakers does not necessarily require 200kA bus
Breaker frame size and type determine the width of the breaker bracing. Bus bracing should be based on the available short
sections and also the minimum depth of the switchgear line-up. circuit current on the switchgear bus.
Refer to tables below for properly sizing Entellisys line-ups. The
8. 200kA bus bracing can limit feeder breaker placement. 200kA
depth of the entire line-up is determined by the deepest device in
bus bracing does not allow adjacent 22 inch wide sections.
the line-up. For example, a line-up with an EGF-20 breaker with a
fuse roll-out (depth 60") and EGF-08 breakers (depth 67") would 9. Factory review of layout is required for bus bracing greater
be a minimum of 67" deep the EGF-08 being the deepest device. than 100kA
Also refer to the section arrangements on the following pages for 10. Some cable entrance designs are not suitable for service
available breaker stacking configurations. entrance. Consult the factory if service entrance is required
for the incoming cable section.
Switchgear Layout Considerations
11. Additional cable and conduit space is available by making
breaker sections wider (22 inch wide to 30 inch wide or 30
1. Sections can be bussed together if there are matching bus
inch wide to 38 inch wide) or by making the line-up deeper
levels in the adjacent sections. Refer to the sample Entellisys
(7 or 14 inches). Refer to the tables below.
line-up.
2. Any breaker compartment shown on the section drawings
can be made blank to provide additional space for mounting
Entellisys devices. Indoor Enclosure Depth Options
Available Depth Options
3. The ampere ratings shown beside each breaker symbol Front compartment 30" 37"
indicate the range of frame sizes that are allowed in the
particular section arrangement. This takes into consideration Rear compartment
(Std depth or 7" or
the temperature rise in the section due to breaker loading. 30" (std) 37" (7" ext) 44" (14" ext) 30" (std) 37" (7" ext) 44" (14" ext)
14" rear extension)
Refer to ANSI C37.20.1-2002 para 8.4.2.3 for cumulative circuit
breaker loading guidelines.
Total depth 60" 67" 74" 67" 74" 81"
4. Devices cannot be mounted on breaker cubicle doors.
5. 3200A, 4000A, and 5000A fuse roll-outs are the same size as
their respective breakers, therefore any compartment shown
with a 3200, 4000, or 5000 amp breaker will also accommo-
date a fuse roll-out and vice versa.

Breaker Device Combination Frame Size Breaker Cubicle Minimum Section Minimum Equipment Depth Optional Equipment
Type or Bus Rating (Amperes) Vertical Height (Inches) Width3 (Inches) [Front/Rear Compt] (Inches) Depth (Inches)
EGS-08 800 21 22 60 [30/30] 67/74
EGH-08 800 21 22 60 [30/30] 67/74
EGX-08 800 21 22 60 [30/30] 67/74
EGF-08 800 21 22 67 [37/30] 74/81**
EGS-16 1600 21 22 60 [30/30] 67/74
EGH-16 1600 21 22 60 [30/30] 67/74
EGF-16 1600 21 22 67 [37/30] 74/81**
EGS-20 2000 21 22 60 [30/30] 67/74
EGF-20 with fuse roll-out 2000 56 30 60 [30/30] 67/74/812
EGS-32 3200 35 30 60 [30/30] 67/74/812
EGH-32 3200 35 30 60 [30/30] 67/74/812
EGX-32 3200 35 30 60 [30/30] 67/74/812
EGF-32 with fuse roll-out 3200 84 38 67 [37/30] 74/81**
EGS-40 4000 35 30 60 [30/30] 67/74/812
EGX-40 4000 35 30 60 [30/30] 67/74/812
EGF-40 with fuse roll-out 4000 84 38 67 [37/30] 74/81**
EGS-50 5000 35 38 74 [37/37] 81**
EGX-50 5000 35 38 74 [37/37] 81**
EGF-50 with fuse roll-out1 5000 35 38 74 [37/37] 81**
1600-4000A main bus rating 60 [30/30] 67/74/812
5000A main bus rating 67 [30/37] 74/812
1 Breaker and fuse roll-out must be mounted in separate vertical sections.
2 81" depth available only when these devices are used in a line-up with items identified with **.
3 Section width can be increased for additional cable / conduit space. 22" sections can be increased to 30" wide, 30" wide sections can be increased to 38" wide.

17-2 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Section Updated 07 / 2016
Medium Voltage Equipment Section 18

MV One Line.................................................................................18-2
Motor Control Medium Voltage (Limitamp)
Introduction, Features, Types, Options, References ................18-3
Specifications, Ratings, Equipment
Reference Publications ......................................................................18-4
Product Scope ...........................................................................................18-5
Renewal Parts............................................................................................18-6
Switchgear Type Power/Vac
Introduction, Publications....................................................................18-8
Power/Vac Vacuum Metalclad Switchgear,
and Breakers...........................................................................................18-9
Characteristics, Symmetrical Rating Basis ...............................18-10
Vacuum Circuit Breakers and Frames ........................................18-11

Rev. 11/13 www.geindustrial.com BuyLog Catalog 18-1


Data subject to change
without notice
Medium Voltage Equipment Section 18
MV One Line

Utility

Voltage Regulators Power Equipment


Center Paralleling
and MV transformers Switchgear
G G
MV Surge
Power Meters
Arrestors
50
51 M Protective Relays
52 (GE Multilin) 52 52

MV 50 50 50 50
Switchgear 51 51 51 51
MV Circuit
52 52 52 52 52
Breakers

Capacitor
Banks
Auto-Transfer
Switches
MV
Fuses
MV Load Secondary Sub-
Interrupter station Transformers
Switches
Low Voltage

MV Motor Control
and Drives

MV Motors M M M M
Power Monitoring
Ethernet Software
Network Design
and Equipment
Hub

18-2 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Medium Voltage Equipment Section 18
Motor Control Limitamp
Limitamp Medium Voltage Motor Control
2400-7200 Volts

The GE Limitamp motor control center provides an economical


means of centralizing motor starters and related control
equipment. It permits motor control starters, feeders, isolator
switches, distribution transformers, interlocking relays,
programmable control, metering and other miscellaneous devices
to be obtained in a single floor-mounted structural assembly fed
from a common enclosed main bus.
Limitamp motor control centers are constructed of standardized
heavy gauge vertical sections housing vertical and horizontal
buses and compartmented starters. Sections are bolted together
to form a single line-up assembly. The entire center may be
powered by incoming line connection at a single point. When
requested and possible, Limitamp motor control centers bear
UL section and unit labels.
Limitamp Control is designed to meet NEMA ICS 3, Part 2 and
UL 347 requirements. Various enclosure types and constructions
are available and there is a broad selection of modifications for
complete control and protection of motors used on modern power-
utilization systems with high available short-circuit currents.
Limitamp AR is the Arc Resistant version of the Limitamp,
providing a state of the art solution under arc flash conditions,
increasing the safety and protection defined in the applicable
IEEE C37.20.7-2007 Type 2B standards.
The Limitamp AR is available for a variety of motor starters,
maintaining the same basic characteristics as the CR194
Limitamp and the vacuum contactor. Starter Types
FVNR Full voltage non-reversing
This program is limited and restricted. Please contact your
(induction and synchronous)
distributor or GE for scope, pricing, and ordering.
RVAT Reduced voltage autotransformer
Product Features RVPR Reduced voltage primary reactor
FVR Full voltage reversing
Visible blade disconnect switch
2S1W Two-speed, one winding
Proven, high reliability vacuum contactors (2 million operations)
2S2W Two-speed, two winding
Quick-make / quick-break disconnect switch
MVSS Medium voltage solid state
Modular, flexible enclosure construction
Feeders Transformer feeders
Extensive protective relays from GE Multilin
Epoxy insulated bus available Construction Options
Drawout and stationary contactors
Main bus: 1200A, 2000A, 3600A (AR version up to 3000A)
1 high and 2 high arrangements
System voltages: 2400V, 3300V, 3600V, 4160V, 4800V,
UL / cUL available on most units
6600V, 7200V
Large isolated low voltage compartment
Contactor sizes: 400A, 800A
No rear access required
Enclosure types: NEMA 1, 1A, 2, 3R, (Limitamp AR only for
Matching line-up with all existing Limitamp installed equipment
indoor) 12
AR version: Bus bracing: 50 KA symmetrical
Reinforced doors and panels to guarantee appropriate
protection under arc flash conditions
Internal construction to ensure the arc flash products and gases Limitamp Medium Voltage Motor Control
are directed to the upper section of the enclosure
State of the art vent/flap mechanism to allow the gases to Product References:
evacuate the enclosure and be contained in the Arc Duct Engineered Products Catalog Section 11
or Plenum Application and Selection Guide GET-6840

Arc Plenum on top of each arc resistant vertical section with


provision to be extended as required

Rev. 11/13 www.geindustrial.com BuyLog Catalog 18-3


Data subject to change
without notice
Medium Voltage Equipment Section 18
Motor Control Limitamp
Limitamp Medium Voltage Motor Control
2400-7200 Volts

Key Product Specifications Publication References for Limitamp Equipment


Main AC Horizontal Bus Ratings Publication Description Stocking Location
1200A, 2000A (1950A non-ventilated), or 3600A CR194 Vacuum Design
(2800 non-vented) DEA-328 Medium Voltage Soft Starters Bloomington1
50 kA rms sym short circuit GEH-6263 2-high Maintenance Instructions Bloomington1

Tin or silver plating available GEH-5305 1-high Maintenance Instructions Bloomington1

Epoxy insulation available GET-6840 Selection & Application Bloomington1

Matching line-up with all existing Limitamps DET-064 Advertising Brochure Bloomington1

(including Air Break) GEH-5396 800 Amp 1-high Maintenance Bloomington1

Auxiliary sections available for the Limitamp AR GEF-8016 Contactor Renewal Parts Mebane
GEH-5306 Contactor Maintenance Instructions Bloomington1
Fuses/Curves
Typical Current Ratings (amps) 2 HI only GES-5000 Power Fuse Curves Bloomington1

Vented: 360 top/400 bottom General Purpose Controls

Non-vented: 320 top/320 bottom GEP-1260 Control CatalogCovers Full Line of Products Bloomington1

Arc Resistant: Non-vented 320 top/320 bottom Pilot Devices


GEA-10877 CR104P Push Buttons and Pilot Lights Bloomington1
Relays and Timers
Interrupting Ratings GEH-4115 CR120B AC Relays Bloomington1
Class E1 mVA 25 at 2.5kV
GEH-4120 CR120B Latched Relays Bloomington1
50 at 5.0kV
75 at 7.2kV GEH-6248 CR4 Control and Timing Relay Bloomington1
Class E2 mVA
GEH-5475 C-2000 Mini-Contactors Control Relays Bloomington1
2400 volts 200
3600 volts 300 1601-0057 Multilin 469 GE Multilin
4160 volts 350 1601-0077 Multilin 369 GE Multilin
4800 volts 400
1601-0025 Multilin 269 GE Multilin
7200 volts 600
1601-0013 Multilin 269+ GE Multilin
1601-0060 Multilin 239+ GE Multilin
Contactor RatingsCR193B and CR193D (400A) Metering
Short-time current (amps) GEH-6302 Power Leader EPM, User's Guide Bloomington1
30 seconds 2400 GEH-5892 Power Leader, User's Guide Bloomington1
1 second 6000
1 Ordering address on BuyLog page 27-1.
Impulse withstand (kV) 60
Dielectric strength (kV) 1 minute 18.2
Switching frequency (ops/hour) 360
Mechanical life (ops) 2,000,000
Electrical life (ops) 1,000,000
Closing time (max. ms) 350
Opening time (max. ms)
PLENUM 24.0
switched at coil 50
Pick-up voltage (% of rated) 85% max.
Drop out voltage (% of rated) 10%-65%
Control voltage (volts) requires
rectification 110/115 AC
Control circuit burden (VA)
Closing 175
Hold-in 30
Contactor weight 75 lbs. (35 kg)
Standards applicable UL 347
NEMA ICS 3, Part 2
cUL H

CR194 AR 400A, Stationary or Draw-out, Outline Dimensions


Description Height (in.) Width (in.) (Depth (in.)
1-High, 36" wide, BTM Cable Entry 90 36 42
1-High, 40" wide, BTM Cable Entry 90 40 42
1-High, 36" wide, TOP Cable Entry 90 36 42
1-High, 40" wide, TOP Cable Entry 90 40 42 D W
2-High, 36" wide, BTM Cable Entry 90 36 42
2-High, 40" wide, BTM Cable Entry 90 40 42 SIDE VIEW FRONT VIEW

2-High, 36" wide, TOP Cable Entry 90 36 42


2-High, 40" wide, TOP Cable Entry 90 40 42 CR194 AR 400A Outline Dimensions

18-4 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Medium Voltage Equipment Section 18
Motor Control Limitamp
Limitamp Medium Voltage Motor Control
2400-7200 Volts

Limitamp Product Scope


Product/ Max. Fault Max. Current Power Fuse Overload Potential
Application Rating Rating (Amps) Main Bus Rating1 Enclosure Size2 Types Relays3 Transformers
One High
CR194 400A 5,13 1200A CR324C
1-high14,15 GE Type
Vacuum Stationary 50 kA rms sym.11 360A vented 2000A 26W x 90H x 30D RB N/A
Control (FVNR) 4.80 kV (fused) 320A non-vented 3600A12 Multilin
(34W optional) Bolted or Clip
(induction motor or (2800A non-vented) 269+10
transformer loads

Two High TOP: 360A vented 1200A8 CR324C


2-high14 GE Type
CR194 400A 5,13 50 kA rms sym.11 320A non-vented 2000A 36W x 90H x 30D RB N/A
Vacuum Stationary 7.2 kV (fused) BOTTOM: 400A vented (1950A non-vented) (40W optional) Bolted or Clip Multilin
or Drawout (FVNR) 320A non-vented 3600A12 269+10
(2800A non-vented)
One High
CR194 800A5,13
1200A & 2000A Ferraz CR324C
Vacuum Stationary
50 kA rms sym. 760A vented 3600A12 48W 1-high Shawmut N/A
or Drawout (FVNR)
4.80 kV (fused) 640A non-vented (2800A non-vented) 480W x 90H x 30D Type RB Multilin
(induction motor or
Bolted 269+10
transformer loads)
320A 1-high non-vented
CR7160 400A 9 1-high
360A 1-high vented CR324C
Air-Break Drawout 1000A & 2000A 34W x 90H x 30D GE
50 kA rms sym. 310A 2-high vented
(FVNR)
4.80 kV (fused) 250A 3-high vented 3600A12 (42W optional) Type RA
Multilin
N/A
(induction motor or (2800A non-vented) 2-high & 3-high or RB
310A 3-high, with only 269+
transformer loads) 44W x 90H x 30D
2 contactors

IC1074 1200A6 1200A vented w/o fuse 1000A & 2000A ITI
Load Break Switch 38 kA rms sym. 1000A non-vented w/o fuse Ferraz
3600A12 38W x 90H x 30D N/A stationary
(stationary) 4.76 kV (fused) 960A vented with fuse Shawmut
(2800A non-vented) drawout
(main, feeder, or tie) 840A non-vented with fuse
Auxiliary Sections7 1000A & 2000A 90H x 30D ITI
38 kA rms sym.
(incoming line,
4.76 kV
Per devices installed 3600A12 any width available N/A N/A stationary
metering auxiliary) (2800A non-vented) (22" minimum) drawout
NOTES:
1 Copper only, silver or tin plating, insulation available.
2 NEMA 1 only, gasketing available. NEMA 2, 12, 3R available.
3 CR324 is ambient-compensated.
4 With primary and secondary fuses. Remote control power available.
5 Mechanical latch available. Capacitor trip device also available with latched contactor.
6 A switch may be used for isolation only.
7 Surge arresters available: GE #9L11XPB Polymer series.
8 Epoxy-coated.
9 Obsolete design-for replacement only.
10 Multilin 239, 269, 369, 469 available.
11 7.2 kV application available.
12 Adds 12 inches to depth.
13 Available in Arc Resistant Type 2B.
14 24 inch top for Plenum in AR version.
15 AR version not available in 26 and 34 1-high.

Rev. 11/13 www.geindustrial.com BuyLog Catalog 18-5


Data subject to change
without notice
Medium Voltage Equipment Section 18
Motor Control Limitamp
Frequently Requested Limitamp Renewal Parts
CR194 and CR7160

Limitamp Renewal Parts


Limitamp Type
Part Description CR194 CR7160 Product Number
Arc Chute Assembly Load Break Switch 204B4051BTG1
Blade Assembly Load Break Switch 204B4051BRG1
N/A 9F60DJD025
N/A 9F60DJD030
N/A 9F60DJD040
N/A 9F60DJD050
N/A 9F60DJD065
9F60 Series
N/A 9F60DJD080
N/A 9F60DJD100
N/A 9F60DJD125
N/A 9F60DJD150
N/A 9F60DJD200
9F62HCB025
9F62HCB030
9F62HCB040
9F62HCB050
9F62 G.P. Series 9F62HCB065
E Rated Fuses
Equivalent Cont. 9F62DCB080
Current Rating 9F62DCB100
9F62DCB125
9F62DCB150
9F62DCB175
9F62DCB200
9F62HCB025
9F62HCB030
9F62HCB040
9F62HCB050
9F62 G.P. Series
9F62HCB065
Equivalent XFMR Protection
9F62DCB080
9F62DCB125
9F62DCB150
9F62DCB175
Air - Clip (5kV, 70A) 218A4291P2RB
Air - Clip (5kV, 100A) 218A4291P3RB
Air - Clip (5kV, 130A) 218A4291P4RB
Air - Clip (5kV, 170A) 218A4291P6RB
Air - Clip (5kV, 200A) 218A4291P9RB
Air - Clip (5kV, 230A) 218A4291P12RB
Air - Clip (5kV, 390A) 218A4291P18RB
Air - Clip (5kV, 450A) 218A4291P24RB
Air - Bolted (5kV, 70A) 218A4293P2RB
Air - Bolted (5kV, 100A) 218A4293P3RB
Air - Bolted (5kV, 130A) 218A4293P4RB
Air - Bolted (5kV, 170A) 218A4293P6RB
Air - Bolted (5kV, 200A) 218A4293P9RB
Air - Bolted (5kV, 230A) 218A4293P12RB
Air - Bolted (5kV, 390A) 218A4293P18RB
Air - Bolted (5kV, 450A) 218A4293P24RB
Vac. - Bolted (5kV, 70A) 55A212942P2RB
Vac. - Bolted (5kV, 100A) 55A212942P3RB
Vac. - Bolted (5kV, 130A) 55A212942P4RB
Vac. - Bolted (5kV, 170A) 55A212942P6RB
Vac. - Bolted (5kV, 200A) 55A212942P9RB
R Rated Fuses Vac. - Bolted (5kV, 230A) 55A212942P12RB
Vac. - Bolted (5kV, 390A) 55A212942P18RB
Vac. - Bolted (5kV, 450A) 55A212942P24RB
Vac. - Bolted - 800A (5kV, 425A) 55A213937P425B
Vac. - Bolted - 800A (5kV, 550A) 55A213937P550B
Vac. - Bolted - 800A (5kV, 630A) 55A213937P630B
Vac. - Bolted - 800A (5kV, 800A) 55A213937P800B
Air - Bolted (7.2kV, 70A) 218A4298P070
Air - Bolted (7.2kV, 100A) 218A4298P100
Air - Bolted (7.2kV, 180A) 218A4298P180
Air - Bolted (7.2kV, 360A) 218A4298P360
Vac. - Bolted (7.2kV, 70A) 55A212943P70
Vac. - Bolted (7.2kV, 100A) 55A212943P100
Vac. - Bolted (7.2kV, 180A) 55A212943P180
Vac. - Bolted (7.2kV, 360A) 55A212943P360

18-6 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Medium Voltage Equipment Section 18
Motor Control Limitamp
Frequently Requested Limitamp Renewal Parts
CR194 and CR7160

Renewal Parts (continued)


Limitamp Type Product
Part Description CR194 CR7160 Number
Air or Vac Clip, 7.2kv, 70A 9F60LJE503
Air or Vac Clip, 7.2kv, 130A 9F60LJE504
Air or Vac Clip, 7.2kv, 170A 9F60LJE506
R Rated Fuses Air or Vac Clip, 7.2kv, 200A 9F60LJE509
Air or Vac Clip, 7.2kv, 230A 9F60LJE512
Air or Vac Clip, 7.2kv, 390A 9F60MJE518
Air or Vac Clip, 7.2kv, 450A 9F60MJE524
0.75kVA 2400 to 230/115 Vac 573A350P86
0.75kVA 4160 to 230/115 Vac 573A350P87
Control
2kVA 2400 to 230/115 Vac 573A350P44
Power
2kVA 4160 to 230/115 Vac 573A350P45
Transformer
3kVA 4160 to 230/115 Vac 573A350P53
3kVA 2400 to 230/115 Vac 573A350P54
1 Amp (Use with .75kVA) CSC#A480T1E-1
Primary Fuses 3 Amp (Use with 2kVA) CSC#A480T3E-1
4 Amp (Use with 3kVA) CSC#A480T4E-1
Repl. Bottles Refer to Factory
Vacuum Contactors Refer to Factory

This is a partial listing of GE's medium voltage power fuse offering. GE offers current limiting fuses for a large variety of applications, including full range fuses, potential
transformer fuses, motor starters, capacitor fuses, supports, disconnect switches, and a variety of fuse clips and live parts.
For more information, please contact your local GE distributor, or local GE Energy sales representative. Our catalog (GEP-9013B),
as well as other application and selection information are also available at www.geindustrial.com. If you need further assistance you may contact our
customer service group at 1-800-821-4873 (US only).

Limitamp Parts Publications List


Model Description Number
Instructions (One-High) 400A GEH-5305
Instructions (Two-High) 400A GEH-6263
CR194
Renewal Parts 400A DEF-002
Instructions 800A GEH-5396
Instructions and Maintenance GEH-3091
CR7160 Air Break
Renewal Parts GEF-4630
Maintenance GEH-5306
CR-193 Vac. Contactor
Renewal Parts GEF-8016
Instructions and Maintenance GEH-3102
Air Break Contactor (IC2814 and IC302) Renewal Parts 400A GEF-4551
Renewal Parts 700A GEF-4576
Instructions and Maintenance GEH-4989
CR7160 Drawout Vac. Contactors
Renewal Parts GEF-8017
Load Break Switch (IC1074) Instructions and Maintenance GEH-4268

Rev. 11/13 www.geindustrial.com BuyLog Catalog 18-7


Data subject to change
without notice
Page Updated 07 / 2016
Medium Voltage Equipment Section 18
Switchgear Power/Vac
Medium Voltage Switchgear

For medium-voltage applications, Power/Vac1 metalclad


switchgear is available, utilizing Power/Vac vacuum circuit
breakers.
Power/Vac switchgear is designed to meet a wide variety of
protection and switching applications. All functional units such as
incoming line, radial feeders, feeder bypass, bus-tie, bus-entrance
and auxiliary units are available to give your system-planning
staff a wide range of latitude. These basic functions, plus the
versatility of one-high or two-high stacking, afford maximum
value for your application dollar.
For pricing and application assistance,
contact your local GE sales office.
For more information on these products,
order publications listed in Section 28.

Instructions/Maintenance
Power/Vac Vacuum Circuit Breaker
with ML-17H-4 Rev. 0 and -1 Mechanism 01.4IB.66000A
Power/Vac Vacuum Circuit Breaker
with ML-18 Mechanism Type VB1 (This mechanism no longer in production) GEK-86132
Power/Vac Vacuum Circuit Breaker
with ML-17 Mechanism Models 0, -1, -2, -3 (Previous production design) GEK-39671
Power/Vac Metalclad Switchgear Types 4.16
and 13.8 Installation and Maintenance GEK-39672
Metalclad Switchgear Components (Full Height Frame)
for Power/Vac Circuit Breaker GEK-90209
Metalclad Switchgear Components Box and L frame
for Power/Vac Circuit Breaker GEK-90215
Power/Vac Compartment Kits GEK-103201
Renewal Parts - Power/Vac Vacuum Circuit Breaker
with ML17 Mechanism Models 0, -1, -2, -3 GEF-4705
Renewal Parts - Power/Vac Vacuum Circuit Breaker
with ML18 Mechanism GEK-90218
1500 mVA Bkr GEK-39671 + DEI-002
Power/Vac 27kV Circuit Breaker
with ML-20 Mechanism DEH-40368

1Power/Vac is manufactured by and is a registered trademark of Powell Industries.

18-8 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Medium Voltage Equipment Section 18
Switchgear Power/Vac
Power/Vac Vacuum Metalclad Switchgear, and Breakers

Power/Vac switchgear is designed, assembled and tested to Remote Racking/Control options are available for increased
meet or exceed applicable ANSI, IEEE and NEMA standards. UL safety, and to meet NFPA 70E-2004.
Listing is available as option when requested on breakers and NEMA 1, NEMA 3R and NEMA 3R Walk-in Construction available
cubicles depending on device compliment. Power/Vac Ample relay and terminal block space accepts complex config-
switchgear incorporates the compartment concept with urations. Open doors are securely held with positive stops
grounded metal barriers that segregate primary functions so no so breakers can be inserted or withdrawn without damaging
live parts are exposed. Safety interlocks are standard as well as control, indication or protective devices.
closed door racking and storage, breaker position indicator, and Consistent top-quality manufacturing at ISO-9002 listed facility.
positively-actuated safety shutters. Power/Vac metalclad
switchgear combines the time-honored advantages of GE ANSI
designed metalclad switchgear flexibility, quality and economy, Power/Vac Breaker
along with the benefits of copper-chrome improved Vacuum interrupters provide rapid arc interruption and are not
reliability, longer life, design simplicity, less maintenance, reduced affected by the external environment.
size and weight. Vacuum interrupter contacts require no maintenance and
Furthermore, two-high breaker stacking (one breaker above seldom wear out over the normal duty life-span of a circuit
another in a single vertical section) means added application breaker.
freedom and significant floor space savings. Power/Vac metal- Contact erosion indicator is provided for inspection
clad switchgear incorporates standardized modular construction convenience.
to simplify system planning and lower installation cost. These Primary disconnect fingers are rugged and easy to inspect.
economies are enhanced by the availability of structured protec- Built of silver-plated copper and tested for continuous and
tion, instrumentation and control packages. momentary currents, these disconnects provide proper contact
integrity throughout the life of the gear.
Power/Vac switchgear is designed to meet a wide variety Breaker ratings: 4.76 kV-20KA through 15 kV-63kA, 1200
of protection and switching applications. All functional units such Amperes to 4000 Amperes
as incoming line, radial feeders, feeder bypass, bus-tie, bus- Interrupter support of track resistant polyester glass houses
entrance and auxiliary units are available to give your system vacuum interrupter and primary connection bars. Removed as
planning staff a wide range of latitude. These basic functions, a unit, it simplifies replacement of vacuum interrupters should
plus the versatility of two-high breaker stacking, afford maximum they have to be replaced.
value for your application dollar. Breaker mechanism is stored energy spring-charged providing
The modular design of Power/Vac metalclad switchgear com- fast closing and opening speeds. Parts are high quality
bines with precision tooled parts, computer-aided design and precision tooled to close tolerances for operating consistency,
advanced production techniques to set a new standard of excel- reliability, maintenance ease and long life.
lence exhibited in the superior reliability figures cited earlier. 4000 Amp is fan cooled.

Power/Vac Equipment
Ratings4.76 kV-20KA through 15 kV-63kA For more information on these products:
Two-high breaker stacking can save up to 50% in floor space Power/Vac Descriptive Brochure DEA-398
Power/Vac Application Guide GET-6600
depending on rating, and results in fewer shipping splits.
Power/Vac Switchgear Installation Manual GEK-39672
Main bus compartment is completely isolated by metal barriers. BreakMaster Medium Voltage Load Interrupter DEA-052
All main bus joints have tin plated connections for positive
contact and low resistance and are insulated with preformed
boots (silver plated optional). Bus bars are provided with high For pricing and application assistance,
contact your local GE sales office.
dielectric insulation; they pass through track resistant polyester
glass barriers between cubicles. Porcelain insulation to ground
is optional.
Rugged steel frame employs reinforced steel gussets for added
strength and dimensional integrity.
Breakers are directly racked into position on rails which ensure
proper alignment of primary and secondary connections.
Positive stops are provided in TEST/DISCONNECT and
CONNECT positions.
Precision tooling brings uniform quality to breaker and
equipment parts and facilitates trouble-free field assembly
and operation.
Auxiliary draw-out trays can be mounted above or below
breakers for greater flexibility.

Rev. 11/13 www.geindustrial.com BuyLog Catalog 18-9


Data subject to change
without notice
Medium Voltage Equipment Section 18
Switchgear Power/Vac
Medium-Voltage Switchgear Application Data
Power/Vac Power Circuit Breaker Characteristics

Power/Vac Power Circuit Breaker Characteristics


Symetrical Ratings Basis per ANSI C37.06 - 2009
Available Ratings
Rated Nominal Typical Rated Rated Withstand Rated Short Maximum 2 Peak Close
Maximum ANSI System Voltage Test Voltage Continuous rms Circuit Current Rated Rated Sec Short and Latch
rms Voltage Voltage Operating Range Low Frequency Crest Current Rating (Maximum Interrupting Permissible time Current (2.7K x short
(kV) Class (kV) Voltages Factor, K rms Voltage Impulse at 60Hz Interrupting Time (Cycles) Tripping Delay, Y Carrying circuit current
(1) (kV) (kV) Voltage (kV) (amperes) (2) Capability (Seconds) Capability (kA) rating) (kA)
(kA) (3)
1200-4000 31.5 5 or 3 31.5 82
2400
1200-4000 40 5 or 3 40 108
4.76 4.16 4160 1.0 19 60 2
1200-4000 50 5 or 3 50 135
4200
1200-4000 63 5 or 3 63 170
6600 1200-4000 40 5 or 3 40 108
8.25 7.2 6900 1.0 36 95 1200-4000 50* 5 or 3 2 50 135
7200 1200-4000 63* 5 or 3 63 170
1200-4000 20 5 or 3 20 54
12000
1200-4000 25 5 or 3 25 68
12470
15 13.8 1200-4000 31.5 5 or 3 31.5 85
13200 1.0 36 95 2
1200-4000 40 5 or 3 40 108
13800
1200-4000 50 5 or 3 50 135
14400
1200-4000 63 5 or 3 63 170
1Maximum voltage for which the breaker is designed and upper limit of operation.
2Available current ratings are 1200A, 2000A, 3000A, 3500A and 4000A. 4000A rating is forced-air cooled, indoor constrcution only. 3500A is available in outdoor
construction, but must be derated to 3250A
3At system operating voltages equal to or less than rated maximum voltage.
*Available ratings in addition to the ANSI C37.06-2009 preferred ratings.

18-10 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Medium Voltage Equipment Section 18
Vacuum Circuit Breakers and Frames
Type VB Power/Vac Vacuum
Circuit Breakers and Frames
For pricing and application assistance,
contact your local GE sales office.

Features
VB Power/Vac skeleton frame is designed for use by
OEM switchgear builders.

Flexibility is offered in various frame configurations allowing


breakers to be stacked in a two-tier arrangement.

Breaker compartment includes racking mechanism, stationary


primary disconnects, shutter mechanism and secondary control
with ten foot leads for connection to the control circuits.

Auxiliary compartment includes potential transformer and/or


control power transformer roll-out tray. Transformers, fuses and
Type VB1 4.16 kV-250 mVA
secondary control wiring are supplied by the purchaser.
1200 ampere breaker element
Blank compartments are available when required by switchgear
line-up arrangement.

Breaker storage compartment includes breaker storage rails.

Power/Vac vacuum breaker elements with all ANSI ratings from


20kA through 63kA (ANSI C37.06 2009), 1200 amperes through
4000 amperes. 27kV @ 16kA and 25kA available.

Stored energy, spring-charged operating mechanism for fast


closing and tripping.

Various control voltages for breaker operation are available in


ac or dc.

UL Listing on Power/Vac Breaker available if specified.

Skeleton frame UL Recognized component if specified.

A complete line of accessories is available.

Additional OEM Components are also available. Typical skeleton frame


Box Frames
L Frames (cradle)
Breaker compartment and rollout compartment kits

Contact your local GE sales office for information.

Rev. 11/13 www.geindustrial.com BuyLog Catalog 18-11


Data subject to change
without notice
Medium Voltage Equipment Section 18
NOTES:

18-12 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Paralleling Switchgear Section 19
Critical Power Products

Paralleling Switchgear...............................................................19-2
Energy Commander................................................................................19-3
System Applications ...............................................................................19-5
Ordering Information .............................................................................19-6

Rev. 11/13 www.geindustrial.com BuyLog Catalog 19-1


Data subject to change
without notice
Paralleling Switchgear Section 19
Critical Power Products
Introduction

Paralleling Switchgear Energy Commander has become the leader in supplying solutions
Paralleling is an operation in which multiple power sources, usu- to simple and very complex systems due to its design reliability,
ally two or more generator sets, are connected and synchronized flexibility, uninterruptible maintenance, and operative cost savings.
to a common bus (same parameters with respect to frequency, Energy Commander has evolved and adapted to the changing
phase angle, etc.). technologies in engine generator design, switchgear controls and
monitoring systems. It reflects GEs continuing commitment
to reliable solutions for critical power applications.
Why Paralleling Switchgear?
There are several advantages to be realized when employing
paralleling switchgear in an electrical design such as increased Designed to your specifications in a team effort
reliability, flexibility, ease of uninterruptible maintenance and Complex switchgear systems is where GE excels. With over 30
application/operation cost savings. It is because of these advan- years experience in all types of paralleling applications, our team
tages that paralleling switchgear has become one of the best of systems engineers will work with you to design a system that
choices for meeting todays power requirements. conforms to your exact facility needs. Whether low or medium
Reliability voltage, GE provides you with expert system layout, device
Systems in which part of the load is very critical may be best selection, construction, programming, monitoring, control, startup,
served by paralleling one or more generator sets. Under parallel training, and preventative maintenance services. We will work
operation all the generator sets are started at once. The first set to with you from project inception through commissioning and
reach the proper parameters will assume the most critical portion training to make certain that your project goes smoothly.
of the load, with the remaining sets picking up lower priority loads. Available for all types of systems including emergency power,
In addition, by using a load shedding application, the failure of one peak shave/utility rate incentive, cogeneration and prime power
generator set will not interrupt power to the critical loads, as and utilizing diesel or natural gas reciprocating engines, turbines,
lower priority loads can be dropped offline. fuel cells, multiple utility sources and other prime movers, Energy
Flexibility Commander is truly versatile. In all applications, the systems
Paralleling power sources allows for a wide variety of choices in use the latest technology in programmable control, high-speed
the generation, distribution and utilization of the systems power. networks, data acquisition and operator interface software
and hardware.
Uninterruptible Maintenance
When one engine - generator set is out of service for maintenance Energy Commander products offer designers and owners
or repair, having others synchronized on the same bus can provide an almost unlimited number of configurations and
the necessary back-up power, should an outage occur. operational parameters.
Cost Savings Designed to meet your requirements
Savings can be realized on the application when a number of Operator interface panel with touch screen for system control
smaller sets would be less expensive than one large set or when UL 891, UL 1558 and UL Medium Voltage switchgear
the load makes it impractical to divide into several sections, each listings available
with its own generator. Savings can also occur on the operation GE Intelligent Platforms PLC control and full range of GE
side when generator set life is extended from being used only components including protective relays, breakers, metering and
when needed to support the load. Also, when it is anticipated that monitoring devices, etc.
the load will grow significantly in the future, the capital investment Complete project design and approval drawings coordinated by
can be reduced by starting with small sets and paralleling our experienced project engineers
additional units as load increases dictate. Final instruction manuals including a drawing package that
shows part numbers on all devices, making it easier to order
spare parts and replacements
Why Energy Commander? To/from numbering on the wire ends for easy verification and
debugging
Energy Commander paralleling switchgear has been providing
Field startup and training of site personnel
customer facilities with reliable power switching systems for
Project management from pre-quote services to final
many years and continues its excellence into the 21st century.
acceptance
Since the inception of paralleling switchgear, many successful
Preventative maintenance services
Energy Commander installations have been supplied with a focus
on providing reliability.

19-2 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Paralleling Switchgear Section 19
Critical Power Products
Energy Commander

System Reliability
The Energy Commander Paralleling Switchgear product has sev-
eral hardwired features which ensures trouble-free operation and
maximum reliability. Annunciator panels, load control switches
and meters are all hardwired components. Upon the unlikely
failure of the master control, a back-up engine start operation is
hardwired into the system. Also the programmable logic controller
(PLC) which runs automatic operations is backed up with a true
hardwired manual control.
Finally, as a leader of paralleling switchgear technology, Energy
Commander has an extensive array of successful, trouble-free
installations around the globe. The breadth of experience and
system complexity all make Energy Commander second to none
in the industry.

Ease of Use and Operations


A Master HMI panel can be useful to paralleling switchgear sys-
tems for user access and monitoring. The key control and moni-
toring functions in these systems include metering, annunciation,
controlling breakers and engine generators in automatic
operations as well as manual.
This monitoring and control should be carefully considered when
selecting which type of HMI is best suited for the operator and his
facility. The greatest reliability in monitoring and control functions
is realized with hard-wired analog meters, switches, and annunciation
indicators, with very limited HMI access needs by the operator.
In some cases, critical facilities may be suitable for additional
system monitoring, trouble-shooting, and remote access ability.
Operators in this case will require a more advanced Master HMI in
addition to the system hard-wired meters, switches, and annunci-
ation. The Energy Commander ACS Advanced Control System
is recommended for these cases.
The Energy Commander Operator Interface Panel (OIP) is ideal for
simpler systems. Since status of the system can be viewed in front
of the line-up including all source metering, alarm, shutdown, and
status annunciation, the operator is not required to utilize the OIP
to cycle through any screens for the system control and monitor-
ing. The user is only required to use the touch panel for system
testing purposes, non-critical settings and timing adjustments, and
limited manual control redundant to the hard-wired switches. Optional Advanced Control System (ACS) for Special
Applications
Standard Operator Interface Panel (OIP) Full functions of OIP with the addition of SCADA capabilities.
Intuitive interface makes operation simple. Little or no learning Optionally Internet capable - allows remote access via web.
curve required to operate system. Online controllable / programmable (behind customers
Main screen with navigation buttons and non-system critical own firewall).
button/switches. Advanced Event Logging and Source Trending allows statistical
System testing screen allowing the operator to manually initiate root cause analysis.
automatic system testing operations. Duplicates System and Generator Annunciation.
Generator interface settings latched into the PLC control system Remote system diagnostics.
upon entry. Alarm and maintenance messaging, including predictive
System load add/shed manual control redundant to hard-wired maintenance.
manual control switches in master control. Graphical User interface. Intuitive and user friendly. Requires NO
Generator optimization settings latched into PLC control system computer experience.
upon entry. Password protection. Capable of hundreds of levels of authority.

Rev. 11/13 www.geindustrial.com BuyLog Catalog 19-3


Data subject to change
without notice
Paralleling Switchgear Section 19
Critical Power Products
Energy Commander

System Applications

Emergency or Standby Power


Features Generator Generator
The emergency system is used to supply power to building loads
during a power failure.
Paralleling switchgear controls the system transfer to genera-
tors and return back to normal sequences of operations. ATS
Paralleling switchgear controls the addition of load on/off
generators (load add/shed).
Transfers between utilities and generators occur in open Emergency
transition or passive momentary closed transition (no active ATS
synchronization of sources).
Components
System typically consists of paralleling switchgear product and Emergency
automatic transfer switches of which GE has a wide variety for
many applications. Emergency/Standby Configuration Example

Prime Power
Features
On-site prime power systems are most often used where there
is no utility source available.
The required electricity is generated entirely on-site, typically Generator Generator
at facilities such as island resorts, mines, mills or other
remote locations.
Since utility is not available in prime power systems, ATSs/ATOs
and utility/tie breakers are not required.
Components
Generators are the only source of power. The system typically
consists of PSG product with no ATS/ATO products.
Load Load

Prime Power Configuration Example

19-4 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Paralleling Switchgear Section 19
Critical Power Products
Energy Commander

System Applications

Parallel with Utility


Features Peak Shave Example
Parallel with utility systems are utilized whenever generators are A Peak Shaving application is sometimes used to transfer non-
to be actively synchronized and paralleled with utility sources critical loads onto generators during peak utility demand hours.
for short or long durations.
These systems are often also used for standby use as well.
PSG controls the generators transfer operations with the utility
source(s) as well as the power management (loading controls) kW
Generator
to direct power the appropriate direction. Non-Purchased Power
Transfers may occur in short duration (momentary closed
transition), a somewhat longer duration (softload/unload ON OFF
kW Demand Threshold
closed transition), or a sustained duration (maintained
parallel with utility).
Power management in maintained parallel situations includes Utility
controlling import levels from utility, export levels to utility, or Purchased Power
base load levels where generators are loaded to set amount
disregarding the import and export contribution from utility Time
Co-generation is often used for maximizing generator 9 11 1 3 5 7
8 10 12 2 4 6 8
efficiency with heat recovery systems. Noon
Complies to interconnection requirements of each utility and
IEEE 1547 Standard for Interconnecting Distributed Resources Peak Shave Example
with Electric Power Systems.
Components
System combines generators with utility sources. It typically
consists of PSG product which handles the ATS/ATO operations.
Configuration Example
Parallel with Utility application with Co-Generation heat
recovery system.

Exhaust

Utility Heat Load

Generator Generator Heat


Recovery
System

Feeders

Co-Generation Configuration Example

Rev. 11/13 www.geindustrial.com BuyLog Catalog 19-5


Data subject to change
without notice
Paralleling Switchgear Section 19
Critical Power Products
Ordering Information
Please supply the details below to our Request for Quotation Include this form on all paralleling switchgear projects you send
E-mail inbox @PSGQuotes@ge.com or call 800-637-1738. in for quotes along with:
1. Paralleling Switchgear System Specification
2. One-line Drawings
3. Electrical Room Layout

Todays Date ________________________ Required Quote Date ________________________

Closing Date ________________________ Required Ship Date ________________________

Customer Name ________________________ Location ________________________

Nat. Account or Partnership ________________________ Industry Field ________________________

Sales Engineer ________________________ Project Name ________________________

District ________________________ Phone # ____________________________ Fax # ____________________________

Paralleling Switchgear

Utility Transfer Control Type ATS Only


Open Transfer
Momentary Closed Transition
Softload Closed Transition
Maintained Parallel with Utility
Number of Generators
+ any future required Generators ______________________

List Generator kW Ratings ______________________________________________________________________________

Automatic Transfer Switch (if applicable)


Product Number (Section 14.) ______________________________________________________________________________

19-6 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Uninterruptible Power Supplies Section 20

Power dependency has increased dramatically in the new


business environment based on e-commerce applications,
mobile networks, corporate Internet sites, e-pay and networked
IT structures. Near one-hundred percent system availability is
mandatory in view of the financial and business consequences.
Not only does the absence of power have catastrophic
consequences, but also an unnoticed mains disturbance can
affect your expensive equipment or critical processes. Power
Quality Products are designed to reduce customer risks to
power issues.

Power Quality Services ..............................................................20-2 Digital Energy LP33U Series 208 V (Three-Phase 10-100 kVA)
Digital Energy VCL Series.......................................................20-4 Description, Features and Benefits...............................................20-24
Digital Energy VH Series (700-2000 Rackmount and/or Tower) Technical Specifications and Dimensions .................................20-25
Description, Applications, Features and Benefits .....................20-5 Product Tables UPS and Battery Cabinets.............................20-26
Technical Specifications and Dimensions....................................20-6 Digital Energy SG Series 480 V (Three-Phase 10-750 kVA)
Product Tables UPS and Battery Packs......................................20-7 Description, Features and Benefits...............................................20-31
Digital Energy GT Series 120 V (3000 VA Tower) Technical Specifications and Dimensions (10-150 kVA)......20-33
Description, Applications, Features and Benefits...................20-10 Product Tables (10-150 kVA) UPS, Battery Cabinets,
Technical Specifications and Dimensions .................................20-11 Transformers and Bypass Panels...............................................20-33
Product Tables UPS...........................................................................20-11 Technical Specifications and Dimensions (225-300 kVA) ...20-40
Digital Energy GT Series 120 V (3000 19" Rackmount) Product Tables (225-300 kVA) ) UPS, Battery Cabinets,
Description, Applications, Features and Benefits...................20-12 Transformers and Bypass Panels..............................................20-40
Technical Specifications and Dimensions .................................20-13 Technical Specifications and Dimensions (400-500 kVA)......20-43
Product Tables UPS and Battery Packs...................................20-13 Product Tables (400-500 kVA) UPS, Battery Cabinets,
Digital Energy GT Series (5kVA and 6kVA Tower/Rackmount) Transformers and Bypass Panels..............................................20-43
Description, Features and Benefits...............................................20-14 Software and Connectivity Products (10-500 kVA) ................20-45
Technical Specifications and Dimensions .................................20-15 Spare Parts, Options and Accessories (10-500 kVA) .............20-46
Product Tables UPS and Battery Packs...................................20-16 Services and Commissioning (10-500 kVA)...............................20-47
Digital Energy GT Series (8kVA and 10kVA Tower/Rackmount) Digital Energy TLE Series (225-1500 kW)
Description, Features and Benefits...............................................20-17 Description, Features and Benefits...............................................20-48
Technical Specifications and Dimensions .................................20-18
Product Tables UPS and Battery Packs...................................20-19
Digital Energy LP11U Series 208 V (Single-Phase 5-10 kVA)
Description, Features and Benefits...............................................20-20
Technical Specifications and Dimensions .................................20-21
Product Tables UPS and Battery Packs...................................20-22

Rev. 11/13 www.geindustrial.com BuyLog Catalog 20-1


Data subject to change
without notice
Uninterruptible Power Supplies Section 20
Power Quality Services for the Digital World

Delivering Critical Power Reliability


Improved Reliability for the Entire Site
Facilities with critical power infrastructure need to maintain
a constant supply of clean and reliable power that will keep
business operating at all times.
To help protect your entire electrical infrastructurefrom
the utility meter and the UPS to the critical loadGE offers a
comprehensive array of services that can ensure continuous
operation of controls and equipment during a power loss.
Without an effective diagnostics and maintenance program,
critical power system components (such as battery systems)
are prone to failure.
Uninterrupted Revenue Stream Site Monitoring Moderate cost, high performance system
To avoid potential loss of revenue streams from unplanned outages, incorporates monitoring logging, alarming and a multi-protocol
GE designed a preventive maintenance program that can be notifying system. GE-monitored alarm management response
customized to meet the specific needs of your site. The program program.
also reduces long-term maintenance cost and capital expenditures. Complete Spare Parts Inventory Worldwide sourcing
Single Point of Contact with Worldwide Sourcing capability provides UPS, batteries (VRLA and flooded), DC
Operating from a worldwide network of service centers with a equipment, replacement boards and components for UPS and
large critical parts inventory, our highly trained repair specialists DC equipment.
work at a schedule that accommodates your site needs. With Critical Power Equipment Operator Training Hands-on
extensive experience across multiple brands of equipment, classroom or on-site training to increase operator reliability
they can free your plant personnel to focus on their core and accuracy.
competencies. In order to ensure an effective and rapid response, Battery Preventive Maintenance Services Measure and record
GE provides a single point of contact to coordinate all of your cell float voltage, the specific gravity on all flooded cells and cell
service needs. conductance to determine the relative state of health for VRLA
Expert Inspection and Maintenance Services battery types. Adjust float and equalize voltage settings to
With an average of five years of in-depth experience on manufacturer specific values. Record electrolyte temperature on
equipment across the industry, GE specialists have the required flooded cells and record temperatures on the negative post (on
range of skills to protect your operation from power interruptions. VRLA battery types). Inspect terminals, cables, and hardware;
Expert interpretation of inspection data allows our engineers to cell elements; battery racks, cell covers and post seals.
provide you with the preventive or corrective services that are
most appropriate for your business, including: Benefits
Inspection Services Review customer maintenance logs; perform Greater reliability
safety checks; visually inspect power equipment, batteries and Reduced outages and risk of lost revenues
rectifiers; provide detailed reports with findings and recommendations. Lower capital expenditures and maintenance costs
Single point of contact for all services
Uninterruptible Power Supply (UPS) Preventive Maintenance
Services Verify equipment functionality and provide detailed Reliability Services
reports with findings and recommendations for GE and multi- UPS commissioning and upgrades
vendor systems. Battery installation and maintenance
Rectifier Preventive Maintenance Services Verify operation of Battery replacement
all rectifiers/chargers; read and record DC float voltage; read and System stability and reliability consulting
record AC input voltage and current; and calibrate panel meters. Remote monitoring and diagnostics (RM&D)
Infrared thermal imaging
Remedial Services Test and repair UPS, rectifier and related Asset management services
critical power equipment.
Critical Parts Availability
Remote Monitoring and Diagnostics (RM&D) Advanced
algorithms for data analysis and condition assessment; performance Worldwide critical spare parts inventory and servicing
trending; diagnostics/problem assessment; rapid response for Continually updated database for most efficient sourcing
emergency troubleshooting and addressing technical questions. Global emergency service with rapid response times to meet
your critical needs
Engineering Services Design-build services for ISP facilities; Depot repair staff available to ensure reliability of your electrical
technical and logistical support for multi-vendor equipment and infrastructure
site analysis for power problems (UPS, generator interfacing, Operator training on a variety of multi-vendor power equipment
harmonics or power fluctuations). (on-site or at a GE location)

20-2 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Uninterruptible Power Supplies Section 20
Power Quality Services for the Digital World

Increased Reliability of Critical Power Systems


GEs expertise can help deliver critical power for continuous
operations.
Our comprehensive array of services ensures the reliability of
critical power battery and rectifier/charging systems when they
are needed most. While battery systems are the most crucial
components of a critical power system, they can be prone
to failureunless an effective diagnostics and maintenance
program is in place.
Uninterrupted Revenue Stream
To prevent potential loss of revenue streams from unplanned
outages, GE has designed a preventive maintenance program
tailored to the Transmission and Distribution needs of Independ-
ent Power Providers, Investor Owned Utilities (IOUs), Non-Utility
Generator (NUGs), and municipal and industrial power providers.
In addition to providing reliable power in substations and generat-
ing plants, the program also reduces long-term maintenance cost
Remedial Services Clean and correct all corroded connections;
and capital expenditures.
replenish low electrolyte fluid levels (flooded cells only) and
Single Point of Contact with Worldwide Sourcing apply single unit charge techniques to re-establish string
Operating from a worldwide network of service centers with a balance.
large critical parts inventory, our highly trained specialists work
Battery Replacement Services Install, inspect, test clean and
at a schedule that accommodates your site needs. With extensive
repair of battery systems as well as removal/replacement using
experience across multiple brands of equipment, they can free
EPA registered and approved recyclers.
your plant personnel to focus on core competencies. In order to
ensure an effective and rapid response, GE provides a single point Benefits
of contact to coordinate all of your service needs.
Greater reliability
Expert Inspection and Maintenance Services Reduced outages and risk of lost revenues
GE specialists have the required range of skills to protect your Single Point of Contact
operation from power interruptions. Expert interpretation of Lower capital expenditures and maintenance costs
inspection data allows our engineers to provide you with the Reduced safety risk
preventive or corrective services that are most appropriate Single point of contact for all services
for your business, including: EPA compliant battery recycling
Inspection Services Review customer maintenance logs; Applicable Markets
perform safety checks; visually inspect power equipment,
Commercial
batteries and rectifiers; provide detailed reports with findings
Healthcare
and recommendations.
Utility
Asset Management Services Develop and maintain asset Information Technology
inventories. Defense
Battery Preventive Maintenance Services Measure and Industrial
record cell float voltage; the specific gravity on all flooded cells Critical Parts Availability
and cell conductance to determine the "relative" state of health
Worldwide critical parts inventory
for VRLA battery types. Adjust float and equalize voltage
Rapid access database for most efficient sourcing
settings to manufacturer specific values. Record electrolyte
Depot repair staff available to ensure reliability of Transmission
temperature on flooded cells and record temperatures on
and Distribution networks
the negative post (on VRLA battery types). Inspect terminals,
cables, and hardware; cell elements; battery racks; cell covers
and post seals.
Rectifier Preventive Maintenance Services Verify operation For Emergency Service call: 1-800-637-1738
of all rectifiers/chargers; read and record DC float voltage;
read and record AC input voltage and current and calibrate
panel meters.

Rev. 11/13 www.geindustrial.com BuyLog Catalog 20-3


Data subject to change
without notice
Uninterruptible Power Supplies Section 20
Digital Energy VCL Series
800 - 3000 VA

GEs new line interactive pluggable range of UPS, the VCL Series UL,
is available in tower and/or rack format, 2U high across all ratings.
The UPS is a high performance range available in 800VA, 1100VA,
2000VA and 3000VA.
Please contact your sales representative or refer to the website for
further details.

20-4 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Uninterruptible Power Supplies Section 20
Digital Energy - VH Series
VH700 - 1000 - 1500 2000 UL

Description
GEs VH Series Uninterruptible Power Supply (UPS) connects be-
tween the utility and your critical load, helping ensure that when
the utility drops or fails, your load continues to receive a clean,
constant and reliable power supply. The VH Series UPS is ideal for
protection against utility variances and failures for PC, telecom,
laboratory, industrial and critical process loads.
The VH Series is a true Voltage and Frequency Independent (VFI)
on line, double conversion UPS providing secure power for busi-
ness-critical applications. With a tower and/or rack mount design,
the UPS adapts to adjusting network configurations as facility
load requirements change. Delivering 0.9 output power factor, a
Mean Time Between Failure (MTBF) of 730,000 hours and a three
year warranty standard on UPS and battery, the user can be as-
sured of a high performance, high power and highly reliable level
of power protection.

Applications Features and Benefits


The VH Series UPS is ideal for both standard and non-standard Unique failsafe internal bypass - Continued operation even with
network IT environments including: overload or over-temperature
PCs and servers 2U design for all ratings - Small footprint; parts supplied for
CCTV and security systems tower or rack assembly
Telecom Hot swappable batteries - Simple, fast battery replacement
Railway signaling without disruption to the load
Small to midsized networks Matching battery cabinets - Longer battery life available with
Laboratory analysis equipment the addition of extra battery cabinet(s)
Process control Superior battery management Provides protection to the
Wind turbine pitch controls battery and extends the battery life
Remote monitoring - Easy access and control even for
unmanned or isolated sites
MTBF >730,000 hours - Proven reliability
Increased power handling - 0.9 output power factor delivers
more actual power to the load
Reliability
Voltage and Frequency Independent (VFI) double conversion
Failsafe bypass
Comprehensive warranty and high MTBF
Continuity
Automatic bypass switch
Easy, fast battery replacement
Large charge capacity and boost/float charging
Flexibility
Tower and rackmount, small footprint
Unique high peak load handling
Frequency converter
Compatibility
High output power factor (0.9)
Standard USB connection
Range of communication options

Rev. 11/13 www.geindustrial.com BuyLog Catalog 20-5


Data subject to change
without notice
Uninterruptible Power Supplies Section 20
Digital Energy - VH Series
VH700 - 1000 - 1500 2000 UL

Technical SpecificationsUL approved


Topology VFI, on line double conversion
Nominal output rating VA/W 700/630 1000/900 1500/1350 1920/1740
Overall efficiency at nominal load % >87
Heat dissipation at inverter nominal load,
W 86 123 184 237
PF=0.9. and charged battery
Cooling air (77-86F) CFM 15 21 32 41
Audible noise level at one meter dB(A) < 45 dB(A), load and temperature dependent
Operating temperature range 32 to 104F (0 to +40C) 59-77 F recommended for batteries
Storage temperature range -4 to 122F (-20C to +50C)
Relative humidity Max. 20-95% (non-condensing)
Protection degree Steel-plastic / IP20
Safety UL 1778, 4th Edition
EMC FCC Part-15, Class B
Surge capacity EN61000-4-5: 6kV line-line / 6kV line-earth
Electrostatic discharge immunity EN 61000-4-2, 4kV contact / 15kV air discharge
Transport On pallet / Tower and rack mountable
Color RAL 9005 (black)
Outlet connectors NEMA 5-20R ( additional L5-20R in 2000 VA )
Inlet connectors IEC-C14 in 700-1000VA and C20 in 1500-2000VA
Cooling Forced air

Input converter (rectifier + power factor correction)


Nominal AC input voltage 120V
Input frequency range 45 - 66 Hz
Power factor > 0.99
THDi < 6%
Nominal input current (no charging, Uin = nominal) Adc 6.6 9.1 13.9 16
Inrush current None
DC output voltage 2 x 210V

Battery charger
Battery charging characteristic Constant current charging until boost voltage, then float voltage charging
AC input voltage range 60 to 140V
DC output voltage Vdc 40.5 81
Output current limitation Adc 1.5
Recharge time 3 hours for 90% capacity, standard battery

Battery data
Battery type Sealed lead acid, VRLA
Float voltage at 25C Vdc 40.5 81
Number & rating of 12V batteries (standard version) 3*7Ah 3*9Ah 6*7Ah 6*9Ah
Standard backup time at nominal resistive load min 8 8 7.2 8
End of discharging voltage (Vdc/cell) Vdc 1.66
Standard backup extensions (Table.1 for backup time) NO YES YES YES

20-6 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Uninterruptible Power Supplies Section 20
Digital Energy - VH Series
VH700 - 1000 - 1500 2000 UL

Output converter (inverter)


Input voltage range Vdc 200-220
Nominal output power at PF=0.9 VA 700 1000 1500 1920
Nominal output power with resistive load W 630 900 1350 1740
Nominal AC output voltage Vac 120
Output voltage waveform sine wave
Output voltage tolerance:
- static resistive load < 1%
- dynamic mean deviation over half cycle
(load step 0-100-0%) < 2%
- with measured non-linear load 2.5:1 < 2%
- recovery time to +/-1% 2ms
Overload capability (battery operation) 110% during 4 minutes, 150% during 2 seconds
Short circuit current capability (app. 200ms) 2.1 times nominal current during app. 200 ms
Output frequency 50/60 Hz auto selectable ( Default 60 Hz during cold start )
Output frequency tolerance 0.05% nominal, unless synchronized with mains
Frequency tracking range 10% default ( 2% selectable )
Max. phase shift difference input-output < 1 typical ( max. 7 during tracking frequency range )
Harmonic distortion with linear load < 1%
Harmonic distortion with non-linear load < 6%
Power factor range 0.7 to 1 (Lag & Lead)
Crest factor handling capability of non-linear load Up to 3:1
Output power derating altitude Up to 1000m no derating; Above 1000m 12.5% per 1000m, max. 4000m
Protection Automatic transfer to bypass (if available)
In case of:
- internal circuit failure
- over temperature
- overload / short circuit
Output protected against connection to the mains
Inverter bridge PWM and IGBT technology

Bypass
Primary Element Static switch
Bypass voltage limits -15% to +10% of selected output voltage
Frequency tracking range 10% default ( 2% selectable) of selected output frequency
Slew rate 2 Hz/sec
Overload capability on bypass 120% 3min. 150% 1 min

Interfacing
Potential free contacts (optional) Four change-over contacts signalling following alarms:
- bypass active
- mains failure
- battery low
- general alarm (programmable)
Input terminals for - Remote Power Off
- Battery extension pack DC connector

Note: all indicated values are typical. Variations may be found from one unit to another.

Rev. 11/13 www.geindustrial.com BuyLog Catalog 20-7


Data subject to change
without notice
Uninterruptible Power Supplies Section 20
Digital Energy - VH Series
VH700 - 1000 - 1500 2000 UL
Optional features
SNMP interface card Battery modules extended runtime
An SNMP interface adapter can be placed in the SNMP slot in the Additional battery modules (up to 3) may be connected in parallel
rear panel of the UPS, which allows the data interface to be con- to in order to achieve a longer runtime. Every battery module is
nected directly to an Ethernet or Web. equipped with its DC cabling and it makes connection between
USB/RS232/Relay Card modules very easy and simple.
The card is provided with an USB connector, a 9-pole sub-D con- Increasing of total battery capacity will correspond to a longer
nector and four potential free changeover contacts, representing: recharging time.
mains failure, general alarm, battery low and bypass active.

Table.1 Dimensions and battery run times


Backup Total Nr. of extra Battery cabinet UPS cabinet
UPS time capacity battery Dimensions Shipping Dimensions Shipping
Model (min.) (Ah) cabinets ( HxWxD ) Weight weight ( HxWxD ) Weight weight
VH700 8 7 35 lbs/16 kg 49 lbs/22kg
8 9
3.4x17.2x18.5 inch
26 23 1 3.4x17.2x18.5 inch 60 lbs 68 lbs
VH1000 87x438x470 mm 37 lbs/17kg 53 lbs/23kg
48 37 2 87x438x470 mm 27kg 31kg
66 51 3
7 7
35 21 1
VH1500 64 lbs/29kg 73 lbs/33kg
63 35 2
13.4x17.2x21.3 inch 101 lbs 110 lbs 3.4x17.2x21.3 inch
88 49 3
87x438x540 mm 46kg 50kg 87x438x540 mm
8 9
26 23 1
VH2000 71 lbs/32kg 79 lbs/36kg
50 37 2
74 51 3

Protections and cable sections


Cable sections input and output recommended
by NEC standards
Recommended external fusing of input wiring Alternatively, local standards to be respected
UPS CABLE SECTIONS
Model Mains / Bypass input mm2 AWG
VH 700 15A Class B MCB 1.8 16
VH 1000 15A Class B MCB 1.8 16
VH 1500 20A Class B MCB 2.5 14
VH 2000 20A Class B MCB 2.5 14

20-8 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Uninterruptible Power Supplies Section 20
Digital Energy - VH Series
VH700 - 1000 - 1500 2000 UL
VH 700-2000 VA Series Units - Rackmount or Tower with same unit
Output Dimensions Weight
Product Number Description Input Plug Receptacles Run Time WxDxH (in) Lbs.
UPS25510 700VA 120V 5-15P (4) 5-20R 8 17.2 x 18.5 x 3.4 35
UPS25511 1000VA 120V 5-15P (6) 5-20R 8 17.2 x 18.5 x 3.4 37
UPS25512 1500VA 120V 5-20P (6) 5-20R 7 17.2 x 21.3 x 3.4 64
UPS25513 2000VA 120V 5-20P (6) 5-20R (1) L5-20R 8 17.2 x 21.3 x 3.4 71

External Battery Options


Dimensions Weight
Product Number Description UPS Model WxDxH (in) Lbs.
UPS25268 Extended Runtime 1000VA 17.2 x 18.5 x 3.4 36
UPS25269 Extended Runtime 1500VA & 2000VA 17.2 x 21.3 x 3.4 71

VH Series Options & Accessories Remote Monitoring & Diagnostic System1


Product Number Description Product Number Description
UPS18802 Option card for RS232, USB and relays 26104 iUPSGuard Annual License 12 months from startup
UPS1019070 SNMP/web plug in card 26104-R iUPSGuard Annual Renewal License 12 months from renewal date
UPS-19IN-RAILKIT 19 inch Rail kit for 4 post racks 1Customer must also purchase the UPS1019070 for use with this license

Battery Runtimes (minutes)2


Standard Internal Battery External Cabinets @ 100%
VA 75% Load 100% Load QTY 1 Qty 2 Qty 3
700 12 8 Not available Not available Not available
1000 - UPS25268 12 8 26 48 66
1500 - UPS25269 11 7 35 63 88
2000 - UPS25269 12 8 26 50 74
2Estimated Runtimes

Rev. 11/13 www.geindustrial.com BuyLog Catalog 20-9


Data subject to change
without notice
Uninterruptible Power Supplies Section 20
Digital Energy GT Series
3000 VA Tower

Description
The Digital Energy GT Series Tower UPS provides high quality
power protection in a cost effective package. The GT Series is a
compact, true VFI (Voltage and Frequency Independent) on-line
double conversion high performance device.
The UPS is designed to support and protect mission-critical
applications, and the bypass mode provides high reliability
against mains power disturbances. All GT Series UPSs are micro-
processor controlled and equipped with RS232 communication
and optional SNMP interfacing capabilities for all major operating
systems, with optional battery pack extended runtime options
also available.
On line double conversion technology eliminates power
reliability problems
High visibility graphic display gives the user immediate view of
UPS status
Automatic internal bypass
Programmable switch-off for less critical loads to maximize
up-time of critical devices. (load shedding)
Modern design fits well into an office environment
Applications
Mission Critical Servers
Medical Equipment
ATM / Frame Relay Switches
Banking Systems
Telecoms / PABX
Features and Benefits
High input power factor (>.97) and low input distortion prevents
disturbances to other electrical equipment, thus eliminating the
need for costly filters or over- sized feeders
Compact footprint, easily transportable, robustly designed
system with low audible noise suitable for both office and
industrial environments
Utilizes high-frequency PWM (Pulse Width Modulation) digital
control technique resulting in extremely low output distortion
and fast transient response eliminating the need for over-sizing
the UPS
Robustly designed to handle short-circuit, high overload and
over-heating conditions, thus reducing maintenance and
service costs
GT Series High Crest Factor (3:1) capability makes it ideal for
computer loads while eliminating the need to oversize the UPS
Very wide AC-input voltage capability minimizes the need to
switch to batteries which results in increased battery life
Fully compliant with UL1778 and CSA 22.2-107 standards for
VFI operation providing full power protection for demanding
critical applications
Every GE UPS can be monitored and managed via LAN and
serial connection
UPS management software facilitating operation and
maintenance of the UPS
Available slot for SNMP plug-in card, potential-free relay
contacts, and RS232/contact interface providing maximum
flexibility

20-10 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Uninterruptible Power Supplies Section 20
Digital Energy GT Series
3000 VA Tower

Technical SpecificationsUL approved


Models GT3000T GT3000T208
Rating (VA/W) 3000 / 2400 3000 / 2400
Battery (V/Ah) 72 / 9 72 / 9
Backup Time @ 50% load 14 min. 14 min.
Option for Additional Batteries Yes Yes
Enclosure (see below) B B
Net Wgt Incl. Batteries (kg/lbs) 30 / 66 30 / 66
Input Voltage @ 100% load (VAC) 80-138 160-275
Input Frequency (Hz)1 50 / 60 50 / 60
Output Voltage 100 / 110 / 120 160 / 208 / 275
Output Frequency (Hz)1 50 / 60 50 / 60
6 NEMA 5-15/20R 4 NEMA 6-20R
Number of Outlets
1 NEMA L5-30R 1 NEMA L6-20R
SNMP Compatibility Yes
Core Voltage 120
PWM Yes
Maintenance Bypass Yes
Internal Batteries Yes
Input Performance Range Voltage (-33 to +17%); Frequency (55 to 65)
Output Performance
Output THD Load Non-Linear (<6%); Linear (<3%)
Voltage Regulation Load Static (2%); 0-100% Step (8%)
Overload Capability 150% 30 Seconds
Efficiency >87%
Communications Interface RS232, Plug and Play, open collector alarm output
Color Front bezel: Aluminum Grey (RAL9006); Cabinet: Pure White (RAL9010)
Operating Temperature 32 F 104 F (0 C 40 C)
Relative Humidity 95% non-condensing
Audible Noise (see below)
Safety UL1778, CSA22.2-107
EMC FCC Class B (1kVA), FCC Class A (remaining)
Enclosure NEMA 1
1Auto Selectable
Specifications subject to change without notice.

Dimensions (in/cm) Audible Noise at Unit Front


Height Width Depth 3kVA-T 42dBA - 3.3 feet (1 meter)
Enclosure B 14.7 (37.3) 5.5 (14) 16.7 (42.4)

GT Series - 3.0kVA Single-Phase UPS


Input Output Run time Dimensions Weight
Product Number Description Plug Receptacles 50/100 WxDxH (in) Lbs.
3000VA - (6) 5-20R
UPS16166 L5-30P 14/5 6x17x14.7 66
100/110/120V (1) L5-30R
(4) 6-20R
UPS16171 3000VA 208V L6-20P 14/5 6x17x14.7 66
(1) L6-20R
(4) 6-20R
UPS16172 3000VA- 208V L6-30P 14/5 6x17x14.7 66
(1) L6-20R
(4) 5-15R
3000VA 208-
UPS16171-PDU-G L6-20P (1) L6-20R 14/5 11x17x17 125
208/120V with PDU
(4) 6-20R
- (4) 5-15R
3000VA 208
UPS16172-PDU-G L6-30P (1) L6-30R 14/5 11x17x17 125
208/120V with PDU
(4) 6-20R

Battery Packs For Extended Run Time2


Dimensions Weight
Product Number Description UPS Model WxDxH (in) Lbs.
UPS16323 Tower Extended Runtime 3000VA 6x15x10 46
2Up to 4 individual Extended Battery Packs can be interconnected for increased times.

Battery Runtimes (minutes)3


Standard Internal Battery External Cabinets @ 100% load
VA 50% Load 100% Qty 1 Qty 2 Qty 3 Qty 4
3000 Tower 14 5 14 22 30 42
3Estimated Runtimes
Connectivity, Software and Monitoring
Description Product Number
SNMP interface plug-in card UPS16400
Customer Interface Card UPS17400
19 inch Rail kit for 4 post racks UPS-19IN-RAILKIT

Rev. 11/13 www.geindustrial.com BuyLog Catalog 20-11


Data subject to change
without notice
Uninterruptible Power Supplies Section 20
Digital Energy GT Series
3000 VA 19 Rackmount

Description
The Digital Energy GT Series Rackmount UPS provides a high
quality power protection in a cost effective manner. The GT Series
is a true VFI (Voltage and Frequency Independent) On-line double
conversion high performance device.
The UPS is designed to support and protect mission-critical
applications, and the bypass mode provides high reliability
against mains power disturbances. All GE Digital Energy GT
UPSs are microprocessor controlled and equipped with RS232
communication and optional SNMP interfacing capabilities for all
major operating systems, with extended optional battery pack
runtime options available.
The GT Series is designed especially for typical rack mount
demands, including long backup times and high ambient temper-
atures, but can be a stand-alone unit for increased versatility.
Online double conversion technology eliminates power Features and Benefits
reliability problems High input power factor (>.97) and low input distortion prevents
Rack design provides application versatility disturbances to other electrical equipment, thus eliminating the
Rack height maximizes rack space need for costly filters or oversized feeders
Online double conversion technology eliminates power Compact footprint, easily transportable, robustly designed
reliability problems system with low audible noise suitable for both office and indus-
Easy plug-in connection of battery packs for extended runtime trial environments
Simple to install and operate Utilizes high-frequency PWM (Pulse Width Modulation) digital
Automatic internal bypass control technique resulting in extremely low output distortion
Programmable switch-off for less critical loads to maximize up- and fast transient response eliminating the need for oversizing
time of critical devices (load shedding) the UPS
Robustly designed to handle short-circuit, high overload and
Applications
over-heating conditions, thus reducing maintenance and
PC and Server Networks service costs
EPOS GT Series High Crest Factor (3:1) capability makes it ideal for
Network Components (Routers, Hubs) computer loads while eliminating the need to oversize the UPS
Security Systems Very wide AC-input voltage capability minimizes the need to
Process Control switch to batteries which results in increased battery life
Fully compliant with international standards for VFI (IEC 62040-3)
operation providing full power protection for demanding
critical applications
UPS management software facilitating operation and
maintenance of the UPS
Available slot for SNMP plug-in card, potential-free relay contacts,
and RS232/contact interface providing maximum flexibility

20-12 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Uninterruptible Power Supplies Section 20
Digital Energy GT Series
3000 VA 19 Rackmount

Technical SpecificationsUL approved


Models GT3000R
Rating (VA/W) 3000 / 2400
Battery (V/Ah) 72 / 9
Backup Time @ 50% load 14 min.
Option for Additional Batteries Yes
Enclosure (see below) E
Net Wgt Incl. Batteries (kg/lbs) 34 / 74.9
Input Voltage @ 100% load (VAC) 80-138
Input Frequency (Hz)1 50 / 60
Output Voltage 100 / 110 / 120
Output Frequency (Hz)1 50 / 60
4 NEMA 5-15R
Number of Outlets 4 NEMA 5-20R
1 NEMA 5-30R
SNMP Compatibility Yes
Core Voltage 120
PWM Yes
Maintenance Bypass Yes
Internal Batteries Yes
Input Performance Range Voltage (-33 to +17%); Frequency (55 to 65)
Output Performance
Output THD Load Non-Linear (<6%); Linear (<3%)
Voltage Regulation Load Static (2%); 0-100% Step (8%)
Overload Capability 150% - 30 Seconds
Efficiency >87%
Communications Interface RS232, Plug and Play, open collector alarm contacts
Color Front bezel: Aluminum Grey (RAL9006); Cabinet: Pure White (RAL9010)
Operating Temperature 32 F 104 F (0 C 40 C)
Relative Humidity 95% non-condensing
Audible Noise (see below)
Safety UL1778, CSA22.2-107
EMC FCC Class B (1kVA), FCC Class A (remaining)
Enclosure NEMA 1
1Auto Selectable
Specifications subject to change without notice.

Dimensions (in/cm) Audible Noise at Unit Front


Height Width Depth 3 kVA-R 47dBA - 3.3 feet (1 meter)
Enclosure E 5.2 (13.2 cm) 17.3 (43.9 cm) 19.8 (50.3 cm)

GT Series - Single-Phase UPS Rackmount - 3.0kVA UPS


Input Output Run time Dimensions Weight
Product Number Description Plug Receptacles 50/100 WxDxH (in) Lbs.
(4) 5-20R
3000VA -
UPS16180 L5-30P (4) 5-20R 14/5 17x20x5 75
100/110/120V
(1) L5-30R

Battery Packs For Extended Run Time2


Dimensions Weight
Product Number Description UPS Model WxDxH (in) Lbs.
UPS16327 Rack Extended Runtime 3000VA 17x20x5 80
2Up to 4 individual Extended Battery Packs can be interconnected for increased times.

Battery Runtimes (minutes)3


Standard Internal Battery External Cabinets @ 100% load
VA 50% Load 100% Qty 1 Qty 2 Qty 3 Qty 4
3000 Rack 14 5 14 22 30 42
3Estimated Runtimes

Connectivity, Software and Monitoring


Description Product Number
SNMP interface plug-in card UPS16400
Customer Interface Card UPS17400
19 inch Rail kit for 4 post racks UPS-19IN-RAILKIT

Rev. 11/13 www.geindustrial.com BuyLog Catalog 20-13


Data subject to change
without notice
Uninterruptible Power Supplies Section 20
Digital Energy GT Series
5kVA & 6kVA Tower / Rackmount

Description
With the Digital Energy GT Series, your equipment is protected
from any uctuation in your power source, enabling you to con-
centrate on your core activities. The GT Series is a true VFI (Voltage
& Frequency Independent) on-line double conversion, trans-
formerless, intelligent and high performance UPS.
This UPS provides critical power protection to suit a wide range of
IT Networks, Telecom and other applications. The GT Series is easy
to install and service, and is designed for maximum site exibility.
With an attractively designed modern common tower and/or
19-inch rack mount cabinet, the UPS can adapt as network
congurations adapt.
For communication, the GT series is equipped with RS232 and
contact interface as standard; a web-enabled SNMP card is
available as an option. Operation from remote or unmanned sites
is simple to coordinate with standard remote monitoring function- Applications
ality. No load shutdown, automatic frequency detection, settable Computer and data centers
minimum start-up runtime and extended runtime availability Call centers
with optional battery packs are additional features of the Telecommunications equipment
GT Series UPS. Security systems
Financial institutions
Performance Features
Fixed and mobile voice and data transmission
Rack / Tower Mounting
Auto Sensing 50/60Hz Vertical Markets
Extended Runtime options - Additional Runtime with 2U plug & Healthcare
play Battery Packs Education
Additional Communications SNMP Card Slot Retail
Included Monitoring & Operational Software Entertainment
Built in RS232 Communication port Telecom
Emergency Power Off Terminal Connections for EPO Financial
User Replaceable Hot Swappable Batteries Broadcasting
Standard 2 year warranty
Wide Input Voltage window
Internal Auto and Manual Bypass

20-14 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Uninterruptible Power Supplies Section 20
Digital Energy GT Series
5kVA & 6kVA Tower / Rackmount

Technical SpecificationsUL Listed


Models GT5000 RT GT6000 RT Models GT5000 RT GT6000 RT
Ratings Overload capability
Power ratings depending on input voltage VA / W VA / W Overload behavior during 130% for 10 seconds
100V / 200V : 4000 / 3400 4800 / 3400 battery operation 200% for 2 seconds
110V / 220V : 4500 / 3800 5400 / 3800 depends on rating of
115V / 230V : 5000 / 4000 6000 / 4200 Overload behavior during thermal circuit breaker (TCB)
120V / 208V : 4800 / 4200 5200 / 4200 bypass operation 125% of TCB value for 200 seconds
120V / 240V : 5000 / 4200 6000 / 4200 200% of TCB value for 10 seconds
127V / 220V : 4800 / 4200 5200 / 4200 300% of TCB value for 4 seconds
Input thermal circuit breaker (A) 30 Batteries (ratings given for 25C)
Internal input fuse 250V, slow (A) 30
Nominal voltage (Vdc) 144
Input converter
Qty/ Ah (in battery kit and battery ext. pack) 12pcs / 8Ah
AC input voltage Nominal: 120 / 208 V Type REW45-12 FR
100/(173-200), 110/(190-220), 115/(198- Recharge current 1A
AC input voltage range
230), 120/(208-240), 127/(220) V Battery recharge time
6 hours for 90% capacity
Input current waveform sine wave (batt. discharged at 100% load)
Input current (A) at nominal input voltage 20 General
Input power factor > 0.97
Weight UPS 30.3 Kg (67 lbs)
Input frequency range 40 - 70 Hz
Dimensions UPS (hxwxd) 176x430x592 mm (6.9x16.9x22.55 in)
Input phase (L1 to L2) 120 / 180 / 240 10
Weight battery pack 43 Kg (94.7 lbs)
Inrush current 40
Dimensions battery pack 87x430x592 mm (3.47x16.9x2255 in)
Output converter
Enclosure / protection steel-plastic / IP20
AC output voltage 100 / 110 / 115 / 120 / 127 V (selectable) Mounting Rackmount or Tower mount with same unit
AC output voltage tolerance L-N 3%; L1-L2 5% Environment
Output frequency 50 / 60 Hz, auto selection
Safety Approval UL1778
Output frequency range nominal 5% with mains synchronizing
Electromagnetic compatibility EMI: FCC CFR47 Part 15, class A, ESD:
Output waveform sine wave
IEC61000-4-2, level 4
< 3% with linear load,
Harmonic distortion RS: IEC61000-4-3, level 3, EFT: IEC61000-
< 5% with non-linear full load
4-4, level 4, Surge: IEC61000-4-5, level 3
Power factor at nominal input voltage 0.87 0.8
ANSI C62.41 (IEEE587) Category A
Crest factor (peak to RMS current) 3:1
(level 3) & B (level 1)
Capacity appliance outlets with 55A Terminal Block
Ambient temperature 0 to +40C
Bypass
Audible noise at 3.3 ft . < 55 dB(A), load and temperature dependent
AC input voltage range 15% of selected output voltage Max. relative humidity 90% (non-condensing)
Frequency tracking rate 1Hz/s Color Black - RAL 9005
Frequency tracking range 5% of selected frequency
Typical transfer time, msec 0

Modular PDU Plugs for Single-Phase UPS Tower / Rackmount - 5.0kVA and 6.0kVA
Outlets (NEMA) Input (NEMA)
5-20R T L5-20R L5-30R EN60320 L6-20R L6-30R L14-30R L14-30R
TB2 TB2
Product Number L1-N-G L2-N-G L1-N-G L2-N-G L1-N-G L2-N-G L1-N-G L2-N-G L1-L2-G L1-L2-G L1-N-L2-G
UPS10206211 1 - - - - - - - - - - - 1 -
UPS1020622 1 - - - - - - - - - - - 1 -
UPS1020623 - 2 2 - - - - - - - 1 1 - 1
UPS1020624 - 1 1 - - - - - - 2 - - - 1
UPS1020625 - 2 2 - - - - - - - 2 - - 1
UPS1020626 - - - - - - - 2 2 - - - - 1
UPS1020627 - - - 2 2 1 1 - - - - - - 1
UPS1020628 - - - 2 2 - - - - - 2 - - 1
UPS1020629 - - - - - - - - - 4 - - - 1
1No 3 pole 6 ms maximum transfer time manual bypass.
2 TB = Terminal Block

Battery Run Times


Model Number Load Internal Batteries 1 Battery Pack 2 Battery Packs 3 Battery Packs
10% 75 min 156 min 235 min 313 min
25% 31 min 75 min 115 min 155 min
GT5000 RT / GT6000 RT 50% 14 min 34 min 58 min 82 min
75% 8 min 22 min 35 min 50 min
100% 5 min 14 min 25 min 36 min

Rev. 11/13 www.geindustrial.com BuyLog Catalog 20-15


Data subject to change
without notice
Uninterruptible Power Supplies Section 20
Digital Energy GT Series
5kVA & 6kVA Tower / Rackmount

GT Series 5-6 kVA Units - Rackmount or Tower with same unit


Dimensions Weight
Product Number Description Run Time WxDxH (in) Lbs.
5000VA -
UPS23913UB 5 17 x 23 x 7 137
120/127/208/220/240V
6000VA -
UPS23914UB 5 17 x 23 x 7 137
120/127/208/220/240V

NOTES:
a PDU is required for each 5 or 6 kVA unit - PDUs are replaceable and interchangeable within unit grouping
Internal Battery module (s) will be shipped in a separate box

GT Series 5-6 kVA Communications and Options


Description Product Number
SNMP interface plug-in card UPS1024746
19 inch Rail kit for 4 post racks UPS-19IN-RAILKIT

Remote Monitoring and Diagnostic System1


Description Product Number
iUPSGuard Annual License; 12 months from startup 26104
iUPSGuard Annual Renewal License; 12 months from renewal date 26104-R
1Customer must also purchase the UPS1024746 for use with this license

GT Series 5-6 kVA Battery Packs for Extended Runtime


Dimensions Weight
Product Number Description UPS Model WxDxH (in) Lbs.
UPS23916EBM Extended Runtime 5000VA & 6000VA 17 x 23 x 4 94.7

GT Series 5-6 kVA Runtime Chart


Time in Time in
minutes @ minutes @
UPS Rating Battery Cabinet Qty 50% Load 100% Load
Internal 14 5
5000VA and 1 34 14
6000VA 2 58 25
3 82 36

20-16 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Uninterruptible Power Supplies Section 20
Digital Energy GT Series
8kVA & 10kVA Tower / Rackmount

Description
With the Digital Energy GT Series, your mission- critical equipment
is protected from any uctuation in your power source, enabling
you to concentrate on your core activities. The GT Series is a true
VFI (Voltage & Frequency Independent) on-line double conversion,
transformerless, intelligent and high performance UPS.
This UPS provides critical power protection to suit a wide range of
IT Networks, Telecom and other applications. The GT Series is easy
to install and service, and is designed for maximum site exibil-
ity. With an attractively designed modern common tower and/or
19-inch rack mount cabinet, the UPS can adapt as network
congurations adapt.
Both the power and redundancy of the system can be expanded
by adding units (N+2) to create a parallel system. For communica-
tion, the GT series is equipped with RS232 and contact interface Applications
as standard; a web-enabled SNMP card is available as an option. Computer and data centers
Operation from remote or unmanned sites is simple to coordinate Call centers
with standard remote monitoring functionality. No load shutdown, Telecommunications equipment
automatic frequency detection, settable minimum start-up run- Security systems
time and extended runtime availability with optional battery packs Financial institutions
are additional features of the GT Series UPS. Fixed and mobile voice and data transmission
Performance Features Vertical Markets
Rack / Tower Mounting Healthcare
Auto sensing 50/60Hz Education
Extended Runtime options - Additional Runtime with 2U plug & Retail
play Battery Packs Entertainment
Additional Communications SNMP Card Slot Telecom
Included Monitoring & Operational Software Financial
Built in RS232 Communication Port Broadcasting
Internal/Automatic and manual bypass
User Replaceable Hot Swappable Batteries
User Replaceable Hot Swappable Power Unit
Standard 2 year warranty
Parallel N+2 or N+1 redundancy

Rev. 11/13 www.geindustrial.com BuyLog Catalog 20-17


Data subject to change
without notice
Uninterruptible Power Supplies Section 20
Digital Energy GT Series
8kVA & 10kVA Tower / Rackmount

Technical SpecificationsUL Listed


Models GT8000 RT GT10000 RT Models GT8000 RT GT10000 RT
Ratings Overload capability
Power ratings depending on input voltage VA / W VA / W Overload behavior during 130% for 1 minute
100V / 200V : 6400 / 6400 8000 / 6400 battery operation 200% for 5 seconds
110V / 220V : 7200 / 7200 9000 / 7200 Overload behavior during overload protection
115V / 230V : 8000 / 8000 10000 / 8000 bypass operation 110% of TCB value for 300 seconds
120V / 208V : 8000 / 6900 8700 / 8000 130% of TCB value for 30 seconds
120V / 240V : 8000 / 8000 10000 / 8000 200% of TCB value for 5 seconds
127V / 220V : 8000 / 6900 8700 / 8000 Batteries (ratings given for 25C)
Input thermal circuit breaker (A) 60
Nominal voltage (Vdc) 288
Internal input fuse 250V, slow (A) /Qty 30 / 2
Qty/ Ah (in battery kit and battery ext. pack) 24 / 8Ah
Input converter
Type REW45-12 FR
AC input voltage Nominal: 120 / 208 V Recharge current 1A
AC input voltage range 100/(173-200), 110/(190-220), 115/(198- Battery recharge time
3 hours for 90% capacity
230), 120/(208-240), 127/(220) V (batt . discharged at 100% load)
Input current waveform sine wave General
Input current (A) at nominal input voltage 40
Weight UPS 49.3 Kg (109 lbs)
Input power factor > 0.97
Dimensions UPS (hxwxd) 267x430x660 mm (10.5x16.9x26 in)
Input frequency range 40 - 70 Hz
Weight battery pack 91 Kg (200.4 lbs)
Input phase (L1 to L2)120 / 180 / 240 10
Dimensions battery pack 173x430x660 mm (6.8x16.9x26 in)
Inrush current 40
Enclosure / protection steel-plastic / IP20
Output converter
Mounting Rackmount or Tower mount with same unit
AC output voltage 100 / 110 / 115 / 120 / 127 V (selectable) Environment
AC output voltage tolerance L-N 2% L1-L2 5%
Safety Compliance UL 1778
Output frequency 50 / 60 Hz, auto selection
Electromagnetic compatibility EMI: FCC CFR47 Part 15, class A, ESD:
Output frequency range nominal 5% with mains synchronizing
IEC61000-4-2, level 4
Output waveform sine wave
RS: IEC61000-4-3, level 3, EFT: IEC61000-
< 3% with linear load, < 5% with
Harmonic distortion 4-4, level 4, Surge: IEC61000-4-5, level 3
non-linear full load
ANSI C62.41 (IEEE587) Category A (level
Power factor at nominal input voltage 0.86 0.92
3) & B (level 1)
Crest factor (peak to RMS current) 3:1
Ambient temperature 0 to +40C
Capacity appliance outlets with 55A Terminal Block
Audible noise at 3.3 ft. < 55 dB(A), load and temperature dependent
Bypass
Max. relative humidity 90% (non-condensing)
AC input voltage range 15% of selected output voltage Color Black - RAL 9005
Frequency tracking rate 1Hz/s
Frequency tracking range 5% of selected frequency
Typical transfer time, msec 0

Modular PDU Plugs for Single-Phase UPS Tower / Rackmount - 8.0kVA and 10.0kVA
Outlets (NEMA)
Product Number 5-20R T L5-20R L6-20R L6-30R
L1-N-G L2-N-G L1-N-G L2-N-G L1-L2-G L1-L2-G
UPS1020660 4 4 - - - 2
UPS1020661 2 2 - - 4 -
UPS1020662 2 2 - - - 4
UPS1020663 2 2 - - 2 2
UPS1020664 2 2 1 1 - 2
UPS1020665 - - 2 2 4 -

Battery Run Times


Model Number Load Internal Batteries 1 Battery Pack 2 Battery Packs 3 Battery Packs
10% 107 min 251 min 333 min 494 min
25% 40 min 100 min 160 min 225 min
GT8000 RT / GT10000 RT 50% 16 min 39 min 66 min 92 min
75% 10 min 24 min 41 min 58 min
100% 6 min 17 min 28 min 41 min

20-18 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Uninterruptible Power Supplies Section 20
Digital Energy GT Series
8kVA & 10kVA Tower / Rackmount

GT Series 8-10 kVA Units - Rackmount or Tower with same unit


Dimensions Weight
Product Number Description Run Time WxDxH (in) Lbs.
UPS23917UB 8000VA - 6 17 x 26 x 11 277
120/127/208/220/240V
UPS23918UB 10000VA - 6 17 x 26 x 11 277
120/127/208/220/240V
NOTES:
- 8 & 10 kVA units can be hardwired or have a PDU

GT Series 8-10 kVA Communications and Options


Description Product Number
SNMP interface plug-in card UPS1024746
19 inch Rail kit for 4 post racks UPS-19IN-RAILKIT

Remote Monitoring and Diagnostic System1


Description Product Number
iUPSGuard Annual License; 12 months from startup 26104
iUPSGuard Annual Renewal License; 12 months from renewal date 26104-R
1Customer must also purchase the UPS1024746 for use with this license

GT Series 8-10 kVA Battery Packs for Extended Runtime


Dimensions Weight
Product Number Description UPS Model WxDxH (in) Lbs.
UPS23920EBM Extended Runtime 8000VA & 10000VA 17 x 26 x 7 200.4

GT Series 8-10 kVA Runtime Chart


Time in Time in
minutes @ minutes @
UPS Rating Battery Cabinet Qty 50% Load 100% Load
Internal 16 6
8000VA and 1 39 17
10000VA 2 66 28
3 92 41

Rev. 11/13 www.geindustrial.com BuyLog Catalog 20-19


Data subject to change
without notice
Uninterruptible Power Supplies Section 20
Digital Energy LP11U Series
Single-Phase 5 10 kVA

The Digital Energy LP11U Series is a robust, high-performance


UPS system that provides power protection for a wide range of
mission-critical applications. Every LP11U Series unit operates in
a double conversion mode with true continuous on-line VFI
(voltage and frequency independent) operation, thus yielding
maximum levels of power protection even under the toughest
conditions. In addition, the LP11U Series UPS is easy to install and
service, even in an office environment. Its robust design makes it
suitable for traditional industrial applications as well.
To achieve redundancy or to increase power capacity, GEs
unique Redundant Parallel Architecture (RPA) technology enables
the LP11U Series to parallel up to four units in a flexible and cost
effective manner. In the RPA system, every UPS is controlled in a
true peer-to-peer configuration with redundancy in all critical
elements and functions. This advanced technology provides the
highest possible system reliability for mission critical applications
eliminating any single points of failure associated with other
types of UPS systems. The RPA system precisely synchronizes the
output phase and automatically shares the load supported by
each of the UPS.
Through their complete life cycle, every GE UPS system is fully
supported by GEs Global Services team, which provides world-
class, 24 x 7 preventive and corrective services, training and
application expertise.
Features and Benefits
High input power factor (1.0) and low input distortion prevents Robustly designed to handle short-circuit, high overload and
disturbances to other electrical equipment, thus eliminating the over-heating conditions, thus reducing maintenance and
need for costly filters or over- sized feeders service costs
Compact footprint, easily transportable, robustly designed The LP High Crest Factor (5:1) capability makes it ideal for
system with low audible noise suitable for both office and computer loads while eliminating the need to oversize the UPS
industrial environments Very wide AC-input voltage capability minimizing the need to
Utilizes high-frequency PWM (Pulse Width Modulation) digital switch to batteries which results in increased battery life
control technique resulting in extremely low output distortion Integrated internal manual maintenance bypass reducing the
and fast transient response eliminating the need for over-sizing need for external equipment
the UPS Fully compliant with North American standards for VFI (UL, CUL
Intelligent Energy Management (ECO-mode) enables automatic 1778) operation providing full power protection for demanding
energy savings under stable power conditions critical applications
Redundant Parallel Architecture (RPA) increases system Automatic start-up procedure and a user-friendly interface with
reliability by eliminating single points of failure without multi-language capability simplifying UPS operation
increasing overall system complexity Every GE UPS can be monitored and managed via LAN,
Superior Battery Management (SBM) enhances battery lifetime serial/modem connection or through the Internet
resulting in reduced cost of operation UPS management software facilitating operation and
Fully isolated output providing additional critical power maintenance of the UPS
protection Three available slots for options such as: SNMP plug-in card,
potential-free relay contacts, RPA and RS232/contact interface
providing maximum flexibility

20-20 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Uninterruptible Power Supplies Section 20
Digital Energy LP11U Series
Single-Phase 5 10 kVA

Technical Specifications-UL approved


Models LP5-11U (120) LP6-11U (120) LP8-11U LP10-11U
Rating (VA/W) 5000 / 4000 5000 / 4000 6000 / 4800 6000 / 4800 8000 / 6400 10,000 / 8000
Backup Time @ 50% / 100% loads 25 / 10 min. 25 / 10 min. 20 / 8 min. 20 / 8 min. 29 / 11 min. 22 / 8 min.
Enclosure (see below) A B A B A A
Net Wgt Incl. Batteries (kg/lbs) 134 / 295 175 / 386 134 / 295 175 / 386 175 / 386 186 / 410
Input Voltage (VAC)
Nominal (V) 208 120 208 120 208 208
Range @ 100% Load (V) 162-285 81-141 162-285 81-141 162-285 162-285
Range @ 50% Load (V) 146-285 72-141 146-285 72-141 146-285 146-285
Input Power Factor 0.99
Input Frequency (Hz) 40-70
Output Voltage (VAC) (sinusoidal) 120+208+220/230/240 User Selectable
Output Frequency (Hz) 50 / 60
Output Voltage Regulation +/-1%
Output THD at Linear Load <1%
Output THD at Non-linear Load <2%
Crest Factor Handling Capacity
5:1
of a Non-linear Load
Overload Capability on Inverter 110% 20 min., 130% 3.5 min., 150% 2 min.
Communications Interface RS232, Plug and Play, open collector alarm contacts
Color Front bezel: Aluminum Grey (RAL9006); Cabinet: Pure White (RAL9010)
Environment IP20 (IEC 60529)
Operating Temperature / Humidity 32 F 104 F (0 C 40 C) / 95% Non-condensing
Audible Noise 40-50 dBA - 3.3 feet (1 meter)
Safety Classifications & Listings UL, C-UL: UL1778; CE: EN50091-1-1; EN 60950; IEC 950
EMI FCC Part 15 Class A / EN50091-2
Surge Protection IEC 1000-4-5 (6kV 1.2/50 sec 3kA 8/20 sec) IEEE 587 B, EN 50091-2
Standard Connectivity RS232; programmable alarm contacts; SNMP (optional)
Warranty 24 months

Specifications subject to change without notice.

Dimensions (in/cm)
Height Width Depth
Enclosure A 26.8 (68) 12.3 (31.2) 28.7 (72.9)
Enclosure B 39.2 (99.6) 12.3 (31.2) 28.7 (72.9)

Rev. 11/13 www.geindustrial.com BuyLog Catalog 20-21


Data subject to change
without notice
Uninterruptible Power Supplies Section 20
Digital Energy LP11U Series
Single-Phase 5 10 kVA

LP11U Series - 5kVA to 10kVA Single-Phase UPS


Input Output Power Standard Battery Dimensions Weight Product
Description Voltage Voltage1 Output Run Time (mins.) (H x W x D, inches) (lbs.) Number
Single-Phase, 5 kVA, 208 or 240 V input, 208/240V 120/208/240 5 kVA/4 KW 10 26.8 x 12.3 x 28.7 295 UPS105LP2230000
120/208/240V output, 60 Hz
Single-Phase, 5 kVA, 120V input, 120V2 120/208/240 5 kVA/4 KW 10 39.2 x 12.3 x 28.7 386 UPS105LP1230000
120/208/240V output, 60 Hz
Single-Phase, 6 kVA, 208 or 240 V input, 208/240V 120/208/240 6 kVA/4.8 KW 8 26.8 x 12.3 x 28.7 295 UPS106LP2230000
120/208/240V output, 60 Hz
Single-Phase, 6 kVA, 120V input, 120V2 120/208/240 6 kVA/4.8 KW 8 39.2 x 12.3 x 28.7 386 UPS106LP1230000
120/208/240V output, 60 Hz
Single-Phase, 8 kVA, 208 or 240 V input, 208/240V 120/208/240 8 kVA/6.4 KW 12 26.8 x 12.3 x 28.7 386 UPS108LP2230000
120/208/240V output, 60 Hz
Single-Phase, 10 kVA, 208 or 240 V input, 208/240V 120/208/240 10 kVA/ 8KW 8 26.8 x 12.3 x 28.7 410 UPS110LP2230000
120/208/240V output, 60 Hz
Single-Phase, 10 kVA, 208 or 240 V input, 208/240V 120/208/240 10 kVA/ 8KW 8 26.8 x 12.3 x 28.7 410 UPS110LP223000H
120/208/240V output, 60 Hz;
Vibration Hardened Unit
1Output voltage is 2-wire or 3-wire configuration - 120V (2-wire), 240/120V (center-tapped, 3-wire) or 208V (tapped at 120V, 3-wire).
2Includes 120V input auto-transformer enclosure mounted under the standard UPS enclosure, increasing the overall height from 26.8" to 39.2".

Options and Accessories Connectivity, Software and Monitoring


Description Product Number Description Product Number

RPA-Kit for LP11U UPS15871 SNMP interface plug-in card UPS1009224


(required for each UPS in a RPA system)3 Relay card UPS12458
DC cable, 2.5 mtr + DC connector, UPS15873 IRIS Install Kit (includes modem and 1st year service). UPS11176
required for external batteries Installation labor included if completed
during unit commissioning.
3The RPA-kit contains the following items:
IRIS Annual Fee (after 1st year) UPS11167
Bus-cable for communication between UPSs (2 meters), RS485/422 Converter UPS11227
Bus terminator, RPA plug-in card, Add-on electronic module, (Not needed if ESI is installed,
Thyristor module, Installation guide. or if distance less than 15 meters)

LP11U Series Commissioning and Warranties


Product
Description Number
LP11U Commissioning Service Level 1, 8AM to 5PM Mon/Fri FSUSLP
LP11U Commissioning Service Level 2, 5PM to 8AM Mon/Fri, any time Saturday FSUSLPA
LP11U Commissioning Service Level 3, Sunday and Holidays FSUSLPB
LP11U PM Service. (sold during initial sale) Includes one PM visit at start of coverage (8-5, M-F). PMLP4
Service includes PM for UPS and internal batteries only. Remedial parts/labor and battery replacement not provided.
LP11U Extended Warranty Level 1 (sold during initial sale). Includes one PM visit at start of coverage and WARLPE4
remedial parts/labor (8-5, M-F). Includes internal batteries only.
LP11U Extended Warranty Level 2. (sold during initial sale). Includes one PM visit at start of coverage and FSLP4
remedial parts/labor (7x24, 12 hr response).Includes internal batteries only.

LP11U Series Commissioning and Warranties (RPA systems)


Product
Description Number
UPS Commissioning Service Level 1, 8AM to 5PM, Mon/Fri FSUSLPxxxNz
UPS Commissioning Service Level 2, 5PM to 8AM Mon/Fri, anytime Saturday FSUSLPxxxP1z
UPS Commissioning Service Level 3, Sunday/Holidays FSUSLPxxxP2z
4Extended Warranty coverage is limited to two additional years following the standard warranty.
NOTES: xxx" in the Product Number represents the UPS module kVA rating: '006' for 6kVA, '010' for 10kVA, etc.
"z" in the Product Number represents the total number of UPS modules in RPA systems.
UPS Commissioning by a GE-authorized Service Technician is optional (but highly recommended) for LP11U Series single-phase products.
All equipment installation must be completed prior to commissioning (see Startup Checklist) and must be scheduled two weeks in advance.
LP11U Series UPS are shipped pre-configured for operation at 208V input and output (except for 120V input versions, which are configured for 120V input and 208V output).
Re-configuration of the input and output voltages must be performed and verified by someone familiar with electrical circuits and equipment.
GE strongly suggests that units requiring input/output voltage re-configuration be Commissioned by a GE-authorized Service Technician.

20-22 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Uninterruptible Power Supplies Section 20
Digital Energy LP11U Series
Single-Phase 5 10 kVA

LP11U Series 5 kVA to 10 kVA - External Battery


Dimensions
Description (H x W x D, inches) Weight (lbs.) Product Number
External battery cabinet for LP11U, 7AH 31.1 x 12.3 x 23.2 154 UPS12434
External battery cabinet for LP11U, 14AH 31.1 x 12.3 x 23.2 264 UPS12438
External battery cabinet for LP11U, 21AH 31.1 x 12.3 x 23.2 418 UPSLPB21AH
External battery cabinet for LP11U, 28AH 31.1 x 12.3 x 23.2 528 UPSLPB28AH

LP11U External Battery Packs - Run Time1


5 kVA UPS Rating 6 kVA UPS Rating 8 kVA UPS Rating 10 kVA UPS Rating
External Battery 100% 50% 100% 50% 100% 50% 100% 50%
Product Number Configuration Capacity UPS Load UPS Load UPS Load UPS Load UPS Load UPS Load UPS Load UPS Load
None None None 10 25 8 20 11 29 8 22
UPS12434 UPS12434 7AH 25 60 21 50 22 50 16 39
UPS12438 UPS12438 14AH 45 90 35 75 33 70 25 57
UPSLPB21AH UPS12434 + UPS12438 21AH 60 120 50 100 44 90 34 70
UPSLPB28AH UPS12438 + UPS12438 28AH 80 150 65 130 55 110 43 90
1Approximate run times, including internal UPS battery
NOTES: All LP11U Battery Cabinets include cable and connector for connection to the LP11U UPS.
The 14AH LP11U Battery Cabinet includes connectors for use in paralleling multiple LP11U Battery Cabinets. The 7AH LP11U Battery Cabinet does not include
provisions for paralleling multiple LP11U Battery Cabinets. Only one 7AH LP11U Battery Cabinet can be included in each system.
A maximum of two 14AH LP11U Battery Cabinets may be connected in a system without additional fusing.
Additional cabinets require user supplied 60A fusing.

GE Digital Energy LP11U Series PDU For 5-10kVA Single-Phase UPS


Basic PDU Frame
P/N Description (Req'd for all versions) 5kVA 6kVA 8kVA 10kVA
PDU PDU Frame x x x x

Input Options2
UPS Rating: 5kVA 6kVA 8kVA 10kVA
P/N Description (choose 1) Input V: 120V 208V 240V 120V 208V 240V 120V 208V 240V 120V 208V 240V
I000 208/240V Input, No Input Cord x x x x x x x x
I001 120V Input, No Input Cord x x x x
I002 208/240V Input, 10/3 Input Cord & L6-30P Plug x x
I003 208/240V Input, 8/3 Input Cord & 6-50P Plug x x x x x x
I004 120V Input, 8/3 Input Cord & 5-50P Plug x

Output Options
UPS Rating: 5kVA 6kVA 8kVA 10kVA
P/N Description (choose 3) Output V: 120V 208V 240V 120V 208V 240V 120V 208V 240V 120V 208V 240V
0 Blank Cover Plate - Req'd for unused spaces x x x x x x x x x x x x
1 5-20 Duplex, 120V, 20A (L-N-G) x x x x x x x x x x x x
2 L5-15R, 120V, 15A (L-N-G) x x x x x x x x x x x x
3 L5-20R, 120V, 20A (L-N-G) x x x x x x x x x x x x
4 L5-30R, 120V, 30A (L-N-G) x x x x x x x x x x x x
5 L6-15R, 208/240V, 15A (L1-L2-G) x x x x x x x x
6 L6-20R, 208/240V, 20A (L1-L2-G) x x x x x x x x
8 L6-30R, 208/240V, 30A (L1-L2-G) x x x x x x x x
A 5-50R, 120V, 50A (L-N-G) x x x x x x x
B L14-20R, 208/240V, 20A (L1-N-L2-G) x x x x x x x x
C L14-30R, 208/240V, 30A (L1-N-L2-G) x x x x x x x

Installation Options
P/N Description (choose 1)
IA Factory Installed
RA Field Installed2

Example Product Number and Price:


PDU Frame Input Option Output Option 1 Output Option 2 Output Option 3 Inst. Option
PDU 1003 5 2 A IA
1Input cords, if included, are eight feet long.
2Field installation cost is not included in the PDU price. Field installation must be performed by someone knowledgeable in UPS systems and electrical wiring.

Rev. 11/13 www.geindustrial.com BuyLog Catalog 20-23


Data subject to change
without notice
Uninterruptible Power Supplies Section 20
Digital Energy LP33U Series
Three-Phase 10 - 100 kVA

The Digital Energy LP33U Series is a robust, high-performance


UPS system that provides power protection for a wide range of
mission-critical applications. Every LP33U Series unit operates in
a double conversion mode with true continuous on-line VFI
(voltage and frequency independent) operation yielding maximum
levels of power protection even under the toughest conditions. In
addition, the LP33U UPS is a high efficiency design with low THD
(total harmonic distortion) which takes up less space and is easy
to install and service, especially in an office environment. Its
robust design makes it suitable for traditional industrial
applications as well.
To achieve redundancy or to increase power capacity, GEs
unique Redundant Parallel Architecture (RPA) technology enables
the LP33U Series to parallel up to four units in a flexible and cost
effective manner. In the RPA system, every UPS is controlled in a
true peer-to-peer configuration with redundancy in all critical
elements and functions. This advanced technology provides the
highest possible system reliability for mission critical applications
eliminating any single points of failure associated with other
types of UPS systems. The RPA system precisely synchronizes the
output phase and automatically shares the load supported by
each of the UPS.
Through their complete life cycle, every GE UPS system is fully
supported by GEs Global Services team, which provides world-
class, 24 x 7 preventive and corrective services, training and
application expertise.

Features and Benefits


High input power factor (.98) and low input distortion prevents Robustly designed to handle short-circuit, high overload and
disturbances to other electrical equipment, thus eliminating the over-heating conditions, thus reducing maintenance and
need for costly filters or over-sized feeders service costs
Compact footprint, easily transportable, robustly designed LP33U High Crest Factor (3:1) capability makes it ideal for
system with low audible noise suitable for both office and computer loads while eliminating the need to oversize the UPS
industrial environments Very wide AC-input voltage capability minimizing the need to
Utilizes high-frequency PWM (Pulse Width Modulation) IGBT switch to batteries which results in increased battery life
digital control technique resulting in extremely low output Integrated internal manual maintenance bypass reducing the
distortion and fast transient response eliminating the need for need for external equipment
over-sizing the UPS Fully compliant with North American standards for VFI (UL, CUL
Intelligent Energy Management (ECO-mode) enables automatic 1778) operation providing full power protection for demanding
energy savings under stable power conditions critical applications
Redundant Parallel Architecture (RPA) increases system Automatic start-up procedure and a user-friendly interface with
reliability by eliminating single points of failure without multi-language capability simplifying UPS operation
increasing overall system complexity Every GE UPS can be monitored and managed via LAN,
Superior Battery Management (SBM) enhances battery lifetime serial/modem connection or through the Internet
resulting in reduced cost of operation UPS management software facilitating operation and
Transformerless design for smaller footprint, less weight and maintenance of the UPS
better efficiency Three available slots for options such as: SNMP plug-in card,
potential-free relay contacts, RPA and RS232/contact interface
providing maximum flexibility
Matching battery packs for expanded backup times

20-24 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Uninterruptible Power Supplies Section 20
Digital Energy LP33U Series
Three-Phase 10 - 100 kVA

Technical Specifications-UL approved


Model LP33-10-UL LP33-20-UL LP33-30-UL LP33-40-UL LP33-50-UL LP33-60-UL LP33-80-UL LP33-100-UL
Power Rating Output Capacity 10kVA / 8kW 20kVA / 16kW 30kVA / 24kW 40kVA / 32kW 50kVA / 45kW 60kVA / 54kW 80kVA / 72kW 100kVA / 90kW
Power Factor Output Power Factor 0.8 0.9
Energy Double Conversion Up to 90%
Efficiency Eco Mode Up to 98%
Physical Weight w/o batteries (lbs) 397 430 772 816 1015 1323
Dims ( WxDxH) (inches) (UPS only) 22.7" x 30.7" x 51.6" 23.6" x 29.6" x 71.7" 28.4" x 28.5" x 71.7" 39.4" x 35.4" x 75.0"
Input Input Voltage 3 x 208V + N
Voltage Range -25% / +20% -20% / +15% -15% / +10%
Frequency 60 Hz +/- 10%
Input THD < 8% < 10%
Input Power Factor > 0.98 lagging
Output Output Voltage 120Y / 208 V
Frequency 60 Hz (+/- 1%)
Crest Factor > 3:1
Voltage Regulation
Static +/- 1%
100% Step Load +/- 1% +/- 2%
Voltage Distortion
100% Linear Load < 2% THD < 1.5% THD < 2% THD
100% Non-Linear Load < 3% THD (EN 50091)
Overload Capability
Inverter 125% for 10 minutes; 150% for 1 minute
Bypass 200% for 2 minutes; 2000% for cycle
Battery Battery Type Valve Regulated Lead Acid (VRLA)
Float Voltage 328 VDC @ 68 F (20 C)
Min Discharge Voltage 236 VDC (programmable
General Audible Noise db(A) 50 55 61 62 65 65 68
Operating Temperature UPS: 32 to 104 F (0 - 40 C); Battery: 68 to 77 F (20 - 25 C) recommended
Humidity 0-95%; non-condensing
Safety Classifications & Listings UL/cUL : UL 1778 / IEC62040 / ISO 9001
EMI Classification FCC Part 15, Class A, IEC 62040-2 Class A
Surge Protection IEEE 587-B / ANSI C62.41-B / IEC 1000-4
Communication / Connectivity RS-232; programmable alarm contacts; open collector outputs; SNMP (optional)
Color White (RAL 9003)
Warranty Twelve (12) months after commissioning or eighteen (18) months after shipment, whichever occurs first *

Rev. 11/13 www.geindustrial.com BuyLog Catalog 20-25


Data subject to change
without notice
Uninterruptible Power Supplies Section 20
Digital Energy LP33U Series
Three-Phase 10 - 100 kVA

LP33U - 10kVA to 20kVA Three-Phase On-Line UPS


Input Output Power Standard Battery Dimensions Weight Product
Description Voltage Voltage Output Run Time (mins.) (H x W x D, inches) (lbs.) Number
LP10-33U Three-Phase,
10kVA, 208 V input, 208 V
Output, 60 Hz, no batteries 208V 208 10 kVA/ 8KW 0 51.6 x 22.3 x30.7 UPS301LP2240010
installed - used with optional
extended battery cabinet
LP10-33U Three-Phase, 10kVA,
208V 208 10 kVA/ 8KW 9 51.6 x 22.3 x30.7 640 UPS301LP2240011
208 V input, 208 V Output, 60 Hz
LP10-33U Three-Phase, 10kVA,
208V 208 10 kVA/ 8KW 22 51.6 x 22.3 x30.7 871 UPS301LP2240012
208 V input, 208 V Output, 60 Hz
LP20-33U Three-Phase, 20kVA,
208 V input, 208 V Output, 60 Hz,
208V 208 20 kVA/ 16KW 0 51.6 x 22.3 x30.7 430 UPS302LP2240010
no batteries installed - used with
optional extended battery cabinet
LP20-33U Three-Phase, 20kVA,
208V 208 20 kVA/ 16KW 9 51.6 x 22.3 x30.7 905 UPS302LP2240012
208 V input, 208 V Output, 60 Hz

LP33U - 30kVA Three-Phase On-Line UPS


Input Output Power Standard Battery Dimensions Weight Product
Description Voltage Voltage Output Run Time (mins.) (H x W x D, inches) (lbs.) Number
4W input & output + Gnd, 60 Hz
208/120 208/120 30 kVA/24KW 0 40.6 x 29.9 x 17.7 816 UPS303LP2240010
No internal batteries installed
4W input & output + Gnd, 60 Hz,
208/120 208/120 30 kVA/24KW 10 40.6 x 29.9 x 17.7 1379 UPS303LP2240011
Internal battery (10 min.)
4W input & output + Gnd, 60 Hz,
208/120 208/120 30 kVA/24KW 19 40.6 x 29.9 x 17.7 1665 UPS303LP2240012
Internal battery (19 min.)
4W input & output + Gnd, 60 Hz,
208/120 208/120 30 kVA/24KW 25 40.6 x 29.9 x 17.7 1941 UPS303LP2240013
Internal battery (25 min.)
4W input & output + Gnd, 60 Hz
208/120 208/120 30 kVA/24KW 0 40.6 x 29.9 x 17.7 816 UPS303LP2240020
No internal batteries installed
4W input & output + Gnd, 60 Hz,
208/120 208/120 30 kVA/24KW 10 40.6 x 29.9 x 17.7 1379 UPS303LP2240021
Internal battery (10 min.)
4W input & output + Gnd, 60 Hz,
208/120 208/120 30 kVA/24KW 19 40.6 x 29.9 x 17.7 1665 UPS303LP2240022
Internal battery (19 min.)
4W input & output + Gnd, 60 Hz,
208/120 208/120 30 kVA/24KW 25 40.6 x 29.9 x 17.7 1941 UPS303LP2240023
Internal battery (25 min.)

LP33U - 40kVA Three-Phase On-Line UPS


Input Output Power Standard Battery Dimensions Weight Product
Description Voltage Voltage Output Run Time (mins.) (H x W x D, inches) (lbs.) Number
4W input & output + Gnd, 60 Hz
208/120 208/120 40 kVA/32KW 0 40.6 x 29.9 x 17.7 816 UPS304LP2240010
No internal batteries installed
4W input & output + Gnd, 60 Hz,
208/120 208/120 40 kVA/32KW 8 40.6 x 29.9 x 17.7 1379 UPS304LP2240011
Internal battery (8 min.)
4W input & output + Gnd, 60 Hz,
208/120 208/120 40 kVA/32KW 12 40.6 x 29.9 x 17.7 1665 UPS304LP2240012
Internal battery (12 min.)
4W input & output + Gnd, 60 Hz,
208/120 208/120 40 kVA/32KW 19 40.6 x 29.9 x 17.7 1941 UPS304LP2240013
Internal battery (19 min.)
4W input & output + Gnd, 60 Hz
208/120 208/120 40 kVA/32KW 0 40.6 x 29.9 x 17.7 816 UPS304LP2240020
No internal batteries installed
4W input & output + Gnd, 60 Hz,
208/120 208/120 40 kVA/32KW 8 40.6 x 29.9 x 17.7 1379 UPS304LP2240021
Internal battery (8 min.)
4W input & output + Gnd, 60 Hz,
208/120 208/120 40 kVA/32KW 12 40.6 x 29.9 x 17.7 1665 UPS304LP2240022
Internal battery (12 min.)
4W input & output + Gnd, 60 Hz,
208/120 208/120 40 kVA/32KW 19 40.6 x 29.9 x 17.7 1941 UPS304LP2240023
Internal battery (19 min.)

20-26 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Uninterruptible Power Supplies Section 20
Digital Energy LP33U Series
Three-Phase 10 - 100 kVA

LP33U - 50kVA Three-Phase On-Line UPS


Input Output Power Standard Battery Dimensions Weight Product
Description Voltage Voltage Output Run Time (mins.) (H x W x D, inches) (lbs.) Number
4W input & output + Gnd, 60 Hz 208/120 208/120 50 kVA/45KW 0 28.3 x 28.5 x 77.2 1015 UPS305LP2240010
4W input & output + Gnd, 60 Hz,
208/120 208/120 50 kVA/45KW 7 45.2 x 28.5 x 72.2 2148 UPS305LP2240012
Internal battery (7 min.)
4W input & output + Gnd, 60 Hz,
208/120 208/120 50 kVA/45KW 9 45.2 x 28.5 x 72.2 2397 UPS305LP2240013
Internal battery (9 min.)
4W input & output + Gnd, 60 Hz,
208/120 208/120 50 kVA/45KW 16 62.1 x 28.5 x 72.2 3282 UPS305LP2240014
Internal battery (16 min.)
4W input & output + Gnd, 60 Hz
208/120 208/120 50 kVA/45KW 25 62.1 x 28.5 x 72.2 3779 UPS305LP2240015
Internal battery (25 min.)
4W input & output + Gnd, 60 Hz,
208/120 208/120 50 kVA/45KW 29 79 x 28.5 x 72.2 4415 UPS305LP2240016
Internal battery (29 min.)
4W input & output + Gnd, 60 Hz,
208/120 208/120 50 kVA/45KW 39 95.9 x 28.5 x 72.2 5548 UPS305LP2240017
Internal battery (39 min.)
4W input & output + Gnd, 60 Hz 208/120 208/120 50 kVA/45KW 0 28.3 x 28.5 x 77.2 1030 UPS305LP2240020
4W input & output + Gnd, 60 Hz,
208/120 208/120 50 kVA/45KW 7 45.2 x 28.5 x 72.2 2163 UPS305LP2240022
Internal battery (7 min.)
4W input & output + Gnd, 60 Hz,
208/120 208/120 50 kVA/45KW 9 45.2 x 28.5 x 72.2 2412 UPS305LP2240023
Internal battery (9 min.)
4W input & output + Gnd, 60 Hz,
208/120 208/120 50 kVA/45KW 16 62.1 x 28.5 x 72.2 3297 UPS305LP2240024
Internal battery (16 min.)
4W input & output + Gnd, 60 Hz
208/120 208/120 50 kVA/45KW 25 62.1 x 28.5 x 72.2 3794 UPS305LP2240025
Internal battery (25 min.)
4W input & output + Gnd, 60 Hz,
208/120 208/120 50 kVA/45KW 29 79 x 28.5 x 72.2 4430 UPS305LP2240026
Internal battery (29 min.)
4W input & output + Gnd, 60 Hz,
208/120 208/120 50 kVA/45KW 39 95.9 x 28.5 x 72.2 5563 UPS305LP2240027
Internal battery (39 min.)

LP33U - 60kVA Three-Phase On-Line UPS


Input Output Power Standard Battery Dimensions Weight Product
Description Voltage Voltage Output Run Time (mins.) (H x W x D, inches) (lbs.) Number
4W input & output + Gnd, 60 Hz 208/120 208/120 60 kVA/54KW 0 28.3 x 28.5 x 77.2 1015 UPS306LP2240010
4W input & output + Gnd, 60 Hz,
208/120 208/120 60 kVA/54KW 8 45.2 x 28.5 x 72.2 2397 UPS306LP2240012
Internal battery (8 min.)
4W input & output + Gnd, 60 Hz,
208/120 208/120 60 kVA/54KW 13 62.1 x 28.5 x 72.2 3282 UPS306LP2240013
Internal battery (13 min.)
4W input & output + Gnd, 60 Hz,
208/120 208/120 60 kVA/54KW 19 62.1 x 28.5 x 72.2 3779 UPS306LP2240014
Internal battery (19 min.)
4W input & output + Gnd, 60 Hz
208/120 208/120 60 kVA/54KW 23 79 x 28.5 x 72.2 4415 UPS306LP2240015
Internal battery (23 min.)
4W input & output + Gnd, 60 Hz,
208/120 208/120 60 kVA/54KW 33 95.9 x 28.5 x 72.2 5548 UPS306LP2240016
Internal battery (33 min.)
4W input & output + Gnd, 60 Hz 208/120 208/120 60 kVA/54KW 0 28.3 x 28.5 x 77.2 1030 UPS306LP2240020
4W input & output + Gnd, 60 Hz,
208/120 208/120 60 kVA/54KW 8 45.2 x 28.5 x 72.2 2412 UPS306LP2240022
Internal battery (8 min.)
4W input & output + Gnd, 60 Hz,
208/120 208/120 60 kVA/54KW 13 62.1 x 28.5 x 72.2 3297 UPS306LP2240023
Internal battery (13 min.)
4W input & output + Gnd, 60 Hz,
208/120 208/120 60 kVA/54KW 19 62.1 x 28.5 x 72.2 3794 UPS306LP2240024
Internal battery (19 min.)
4W input & output + Gnd, 60 Hz
208/120 208/120 60 kVA/54KW 23 79 x 28.5 x 72.2 4430 UPS306LP2240025
Internal battery (23 min.)
4W input & output + Gnd, 60 Hz,
208/120 208/120 60 kVA/54KW 33 95.9 x 28.5 x 72.2 5563 UPS306LP2240026
Internal battery (33 min.)

LP33U - 80kVA Three-Phase On-Line UPS


Input Output Power Dimension Weight Product
Description Votage Voltage Output (H x W x D, inches) (lbs.) Number
4W input and output 208/120 208/120 80kVA/72kW 40 x 36 x 75 1,323 UPS308LP2241100
+ Gnd, 60 Hz,
For Use with Matching Battery Cabinets 208/120 208/120 80kVA/72kW 40 x 36 x 75 1,323 UPS308LP2241200

LP33U - 100kVA Three-Phase On-Line UPS


Input Output Power Dimension Weight Product
Description Votage Voltage Output (H x W x D, inches) (lbs.) Number
4W input and output 208/120 208/120 100kVA/90kW 40 x 36 x 75 1,323 UPS310LP2241100
+ Gnd, 60 Hz,
For Use with Matching Battery Cabinets 208/120 208/120 100kVA/90kW 40 x 36 x 75 1,323 UPS310LP2241200

Rev. 11/13 www.geindustrial.com BuyLog Catalog 20-27


Data subject to change
without notice
Uninterruptible Power Supplies Section 20
Digital Energy LP33U Series
Three-Phase 10 - 100 kVA

Options and Accessories


Description Product Number
RPA-Kit for LP33U (required for each UPS in a RPA system)1 UPS11626
SNMP interface plug-in card UPS11701
Extended customer interface card UPS15822
Additional battery charger UPS16139
1The RPA-kit contains the following items:
Bus-cable for communication between UPSs (2 meters),
Bus terminator, RPA plug-in card, Add-on electronic module, Thyristor module, Installation guide.

80kVA Spare Parts Kits 100kVA Spare Parts Kits


Description Product Number Description Product Number
Level A Parts Kit Fuses SK80LP33A Level A Parts Kit Fuses SK100LP33A
Level B Parts Kit Basic SK80LP33B Level B Parts Kit Basic SK100LP33B
Level C Parts Kit Comprehensive SK80LP33C Level C Parts Kit Comprehensive SK100LP33C

LP33U Series Commissioning and Warranties (Single modules only)


Description Product Number
LP33U Commissioning Service Level 1, 8AM to 5PM Mon/Fri FSUSLP33xxxN
LP33U Commissioning Service Level 2, Mon/Sat, Anytime FSUSLP33xxxP1
LP33U Commissioning Service Level 3, Sunday and Holidays, Anytime FSUSLP33xxxP2
LP33U PM Service. (sold during initial sale) Includes one PM visit at start of coverage (8-5, M-F).
PMLP33xxx
PM covers UPS and internal batteries only. Remedial parts/labor and battery replacement not provided.
LP33U Extended Warranty Level 1 (sold during initial sale). Includes one PM visit at start of coverage and
WARLP33xxxE
remedial parts/labor (8-5, M-F). Coverage includes internal batteries only. Maximum 5 years.
LP33U Extended Warranty Level 2 (sold during initial sale). Includes one PM visit at start of coverage and
FSLP33xxx
remedial parts/labor (7x24, 12-hour response). Coverage includes internal batteries only.
LP33U 4-hour Operator Training on site, Mon/Fri, 8AM to 5PM TRNS100N
LP33U Battery Preventative Maintenance. Additional VRLA battery strings for PMs. 8AM-5PM, Mon/Fri. BATSG

LP33U Series Commissioning and Warranties (RPA systems)


Description Product Number
UPS Commissioning Service Level 1, 8AM to 5PM, Mon/Fri FSUSLP33xxxNz
UPS Commissioning Service Level 2, 5PM to 8AM Mon/Fri, anytime Saturday FSUSLP33xxxP1z
UPS Commissioning Service Level 3, Sunday/Holidays FSUSLP33xxxP2z

"xxx" in the Product Number represents the UPS module kVA rating: '010' for 10kVA, '225' for 225kVA, etc.
"z" in the Product Number represents the total number of UPS modules in RPA systems.
UPS Commissioning by a GE-authorized Service Technician is required to initiate warranty coverage.
All equipment installation must be completed prior to commissioning (see Startup Checklist)
and must be scheduled two weeks in advance.

20-28 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Uninterruptible Power Supplies Section 20
Digital Energy LP33U Series
Three-Phase 10 - 100 kVA

LP33U Series 10kVA - Battery Cabinets (non-matching)


10 Year Pro-Rated Battery Warranty
Battery System
Approximate Run Times (minutes) Dimensions Breaker Parallel Product
100% Load1 (H x W x D) Configuration Strings Number
5 43" x 24" x 32.5" 1 x 50A 1 LP33L010PW11
10 43" x 24" x 32.5" 1 x 50A 1 LP33L010PW12
25 43" x 24" x 32.5" 1 x 50A 1 LP33L010PW1Y
35 43" x 24" x 32.5" 1 x 50A 1 LP33L010PW1R
40 43" x 40" x 32.5" 1 x 50A 1 LP33L010PW13
61 43" x 40" x 32.5" 1 x 50A 1 LP33L010PW1S
99 60" x 40" x 32.5" 1 x 50A 1 LP33L010PW1U
136 60" x 40" x 32.5" 1 x 50A 1 LP33L010PW1V
10.8 pF

All run times listed above are based on the manufacturers published data, and do not include connector and wiring losses.
These run times are approxmate and are intended for use as a guide only. Consult factory for guarranteed run times.
All cabinets contain Flame Retardant Batteries.
288 Vdc Nominal - 144 cells - 1.67 Final Volts per Cell, except 1.75 Final Volts per Cell over 60 minutes.
Includes internally mounted circuit breaker(s) sized for the UPS at 100% load. See "Breaker Configuration" column in table above.
Each string, in multi-string systems, is individually fused.
An external, user supplied junction panel is required when multiple battery systems are to be connected to a single UPS.
These cabinets utilize batteries manufactured by Power Battery Company, Inc. and carry a standard 10-year, pro-rated warranty. (Labor and freight not included.)
Optional 5-year, full replacement warranty does not include labor of freight. Total warranty period is 5-years.

LP33U Series 20kVA - Battery Cabinets (non-matching)


10 Year Pro-Rated Battery Warranty
Battery System
Approximate Run Times (minutes) Dimensions Breaker Parallel Product
100% Load1 (H x W x D) Configuration Strings Number
5 43" x 24" x 32.5" 1 x 100A 1 LP33L020PW1Y
15 43" x 40" x 32.5" 1 x 100A 1 LP33L020PW13
24 43" x 40" x 32.5" 1 x 100A 1 LP33L020PW1S
28 43" x 40" x 32.5" 1 x 100A 1 LP33L020PW1T
42 60" x 40" x 32.5" 1 x 100A 1 LP33L020PW1U
65 60" x 40" x 32.5" 1 x 100A 1 LP33L020PW1W
104 60" x 80" x 32.5" 1 x 100A 2 LP33L020PW2U
136 60" x 80" x 32.5" 1 x 100A 2 LP33L020PW2V
10.8 pF

LP33U Series 80kVA - Battery Cabinets (matching)


Run Time H2SO4 Dimensions Weight Product
(minutes) (gal) (H x W x D - in.) Lbs. Number
6 8.82 36 x 30 x 75 2,227 LPH080-1-53-NX
8 9.38 36 x 30 x 75 2,443 LPH080-1-54-NX
14 12 36 x 30 x 75 3,163 LPH080-1-56-NX
24 18.75 72 x 30 x 75 4,886 LPH080-2-54-NX
37 24 72 x 30 x 75 6,326 LPH080-2-56-NX
60 36 108 x 30 x 75 9,489 LPH080-3-56-NX

LP33U Series 100kVA - Battery Cabinets (matching)


Run Time H2SO4 Dimensions Weight Product
(minutes) (gal) (H x W x D - in.) Lbs. Number
5 9.38 36 x 30 x 75 2,443 LPH100-1-54-NX
9 12 36 x 30 x 75 3,163 LPH100-1-56-NX
14 17.63 72 x 30 x 75 4,454 LPH100-2-53-NX
17 18.75 72 x 30 x 75 4,886 LPH100-2-54-NX
26 23.25 72 x 30 x 75 6,326 LPH100-2-55-NX
30 18.13 108 x 30 x 75 7,329 LPH100-3-54-NX
59 46.5 144 x 30 x 75 12,652 LPH100-4-55-NX
65 48 144 x 30 x 75 12,652 LPH100-4-56-NX

Rev. 11/13 www.geindustrial.com BuyLog Catalog 20-29


Data subject to change
without notice
Uninterruptible Power Supplies Section 20
Digital Energy LP33U Series
Three-Phase 10 - 100 kVA

80 kVA -External Wall Mounted Maintenance Bypass System - 3 Breaker MBP - Recommended Configuration
SKRU UIB- Dimensions Weight
Kirk-key MIB/MBB kAIC Rating (H x W x D - in.) Lbs. Product Number
Yes 350A/300A 65 30 x 11 x 42 125 MBP082-303500-K600

100 kVA -External Maintenance Bypass System - 3 Breaker MBP - Recommended Configuration
SKRU UIB- Dimensions Weight
Kirk-key MIB/MBB kAIC Rating (H x W x D - in.) Lbs. Product Number
Yes 400A/350A 65 30 x 11 x 42 125 MBP102-354000-K600

80 kVA and 100kVA UPS Input Transformer Non k-Rated, Aluminum non-matching, NEMA 1 Enclosure
Transformer Voltages kVA Dimensions Weight
Location Primary - Secondary Rating (H x W x D - in.) Lbs. Product Number
Input 480V- 208/120V 150 35 x 24 x 46 775 U9T83B3876

Connectivity, Software and Monitoring Remote Monitoring & Diagnostic System1


Description Product Number Description Product Number
Advanced SNMP/Web interface card, UTP/BNC UPS1018959 iUPSGuard Annual License; 12 months from startup
26104
ModBus TCP License works with UPS1018959 as TCP Interface UPS24864 Single UPS
Customer Interface Card (CIC) 6 programmable relay contacts UPS15822 iUPSGuard Annual License; 12 months from startup
26108
Remote Status Alarm Panel (includes APS) Single UPS with One Year Service Contract (PMLP33XX)
LP-RSAP-CIC
Includes power supply, CIC Card and RSAP iUPSGuard Annual Renewal License; 12 months from renewal date
26104-R
Single UPS; must be sold before existing license expiration
1Customer must also purchase the UPS1018959 for use with this license

20-30 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Uninterruptible Power Supplies Section 20
Digital Energy SG Series
10-150 kVA Three-Phase
225-300 kVA Three-Phase
400-500 kVA Three-Phase
750 kVA Three-Phase

The GE Digital Energy SG Series is one of the best performing


and most reliable three-phase UPS systems providing critical
power protection for a wide range of applications. Every SG
Series system operates in a double conversion mode with true
continuous on-line VFI (voltage and frequency independent)
operation yielding the maximum levels of power reliability for all
mission-critical processes. The Digital Energy SG Series was
developed using GEs Design for Six Sigma methodology to
ensure that the product fully meets customer requirements and
10-150 kVA Three-Phase
expectations.
To achieve redundancy or to increase power capacity, the
Digital Energy SG Series can parallel up to eight units using
GEs unique Redundant Parallel Architecture (RPA) technology in a
flexible and cost effective manner. In the RPA system, every UPS is
controlled in a true peer-to-peer configuration with redundancy
in all critical elements and functions. This advanced technology
provides the highest possible system reliability for mission critical
applications eliminating any single points of failure associated
with other types of UPS systems. The RPA system precisely
synchronizes the output phase and automatically shares the load
supported by each UPS.
The GE UPS systems are designed with serviceability in mind. Any
factory trained service provider can utilize GE's open architecture
to perform diagnostics and maintenance without requiring any
proprietary software or special interface equipment. The systems
are fully supported by GE's Global Services team, which is 225-300 kVA Three-Phase
renowned for its world-class, 24 x 7 preventive and corrective
services, training, and application expertise.

400-750 kVA Three-Phase

Rev. 11/13 www.geindustrial.com BuyLog Catalog 20-31


Data subject to change
without notice
Uninterruptible Power Supplies Section 20
Digital Energy SG Series
10-150 kVA Three-Phase
225-300 kVA Three-Phase
400-500 kVA Three-Phase
750 kVA Three-Phase

Available Options Features and Benefits


Additional battery systems for extended back up times Extremely low output voltage distortion for even non-linear and
Input 5th harmonic filter reduces the input distortion (input THD) 100% step loads reducing the need for over sizing the UPS
to less than 7%; this option is integral to the UPS, no additional Redundant Parallel Architecture (RPA) increases system
cabinet required reliability by eliminating single points of failure without
Additional 11th harmonic filter on 400-750 kVA model to further increasing overall system complexity
reduce the input distortion (input THD) to 5%. This option is Utilizes SVM (Space Vector Modulation), an advanced PWM
internal to the UPS, no additional cabinet required (Pulse Width Modulation) digital control technique, to modulate
Additional input/output isolation and voltage adaptation the inverter resulting in fast transient response with high
transformers available for all kVA sizes and voltages efficiency
External (full wrap-around) maintenance bypass; available in Fully compliant with international standards on Voltage
two or three breaker, panel mounted configurations; Kirk Key Frequency Independent (IEC 62040-3) operation providing full
protection also available power protection for demanding critical applications
Remote status panel: Allows the UPS to be remotely monitored Standard inverter output isolation transformer that isolates
with an UPS panel incorporating indicator lights and alarms utility power from the load, thus providing additional critical
RPA kit: Any single UPS can be easily field-configured for power protection
Redundant Parallel Architecture Superior Battery Management (SBM) enhances battery lifetime
SNMP card: This optional plug-in card allows the resulting in reduced cost of operation
UPS to be managed using an existing network management Intelligent Energy Management (IEM) automatically determines
system or with GEs exclusive UPS management software the most efficient mode of operation for the RPA system thus
UPS monitoring and management software (10-750 kVA reducing overall operating costs
models) Designed for serviceability with front service access reducing
FCC filter for applications where FCC Class A, Part 15 maintenance and repair costs
compliance is required Integrated internal manual maintenance bypass reducing the
Three-wire input conversion kit (225-300 kVA & 400-750 kVA need for external equipment
models) Automatic start-up procedure and a user-friendly interface
simplifying UPS operation
Designed with GEs Six Sigma methodology ensuring high
product quality
Casters and leveling feet easing installation procedure
(10-150 kVA only)
Every GE UPS can be monitored and managed via LAN,
serial/modem connection or through the Internet

20-32 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Uninterruptible Power Supplies Section 20
Digital Energy SG Series
10-150 kVA Three-Phase

Technical Specifications-UL approved


Topology True on-line, double conversion (VFI) with integral static switch and internal maintenance bypass
Technology Advanced IGBT with SVM strategy, microprocessor controlled at optimal switching frequency
Operating Modes True on-line double conversion, automatic bypass, frequency converter, RPA up to eight units

Output Power Rating kVA


(at PF = 0.6 0.8 lag) 101 201 30 40 50 80 100 120 150
Output Power Rating (kW) 8 16 24 32 40 64 80 96 120
Dimensions WxDxH (inches) 27x32x71 27x32x71 27x32x71 27x32x71 32x32x71 32x32x71 47x32x71 47x32x71 47x32x71
Weight w/o Batteries (lbs) 735 763 970 1147 1257 1489 1929 2006 2160
Noise Level dB(A) 60 60 60 60 60 63 65 65 65
Overall Efficiency at 100% Load 91% 91% 91% 91% 92.5% 92.5% 93.3% 93.3% 93.3%
(Double Conversion Mode)
Input Voltage (VAC) 3x480/277 + Neutral ( -20% to +15% without battery discharge)
Input Frequency 60/50 Hz +/-10%
Output Voltage (sinusoidal) (VAC) 3x480/277 + Neutral
Output Frequency 60/50 Hz +/-0.01%
Output THD at Linear Load <2%
Output THD at Non-linear Load <3%
Overload Capability on Inverter 125% 10 min., 150% 1 min.
Overload Capability on Automatic Bypass 200% 5 min., 110% continuously
Output Voltage Regulation
Static +/- 1%
0-100% Step Load +/- 3% recovering to +/-1% in one cycle
Ambient Operating Temp. 32-104F (0- 40C)
Color Black
Classifications and Listing UL1778/IP20/NEMA-PE-1/ISO9001
RFI and Surge Protection EN 50091-2 / IEC 62040-2 / IEEE 587 B / FCC Class A compliance2
Standard Connectivity RS232; alarm contacts; programmable relays, SNMP (optional)
Warranty 12 months
1Units available with internal batteries.
2FCC Feature available as option.
Specifications subject to change without notice.

SG Series 10 kVA UPS (Three-Phase)


Rating Parallel Input Output Dimensions Weight3 Product
Description (0.8 pf) Configuration Voltage Voltage (W x D X H) (lbs.) Number
10 kVA Three-Phase, 4W+G input & output,
10 kVA Single Module 277/480V 277/480V 27x32x71 717 UPS001SG444AN00
single module, 60 Hz
10 kVA Three-Phase, 4W+G input & output,
10 kVA Single Module 277/480V 277/480V 27x32x71 1837 UPSB01SG444AN00
single module, 60 Hz, 14 minute internal battery
10 kVA Three-Phase + EMI Filter (FCC Class A),
10 kVA Single Module 277/480V 277/480V 27x32x71 727 UPS001SG444AY00
4W+G input and output, single module, 60 Hz
10 kVA Three-Phase + EMI Filter (FCC Class A),
4W+G input and output, single module, 60 Hz, 10 kVA Single Module 277/480V 277/480V 27x32x71 1847 UPSB01SG444AY00
14 minute internal battery
10 kVA Three-Phase + EMI Filter (FCC Class A)
+ 5th Harmonic Filter, 4W+G input and output, 10 kVA Single Module 277/480V 277/480V 27x32x71 744 UPS001SG444AY50
single module, 60 Hz
10 kVA Three-Phase + EMI Filter (FCC Class A)
+ 5th Harmonic Filter, 4W+G input and output, 10 kVA Single Module 277/480V 277/480V 27x32x71 1864 UPSB01SG444AY50
single module, 60 Hz, 14 minute internal battery
10 kVA Three-Phase + 5th Harmonic Filter ,
10 kVA Single Module 277/480V 277/480V 27x32x71 734 UPS001SG444AN50
4W+G input and output, single module, 60 Hz
10 kVA Three-Phase + 5th Harmonic Filter ,
4W+G input and output, single module, 60 Hz, 10 kVA Single Module 277/480V 277/480V 27x32x71 1854 UPSB01SG444AN50
14 minute internal battery
3Installed Weight. Note that shipping weight is higher.
Quotation must include cost for Commissioning Service (see SG Service).

Rev. 11/13 www.geindustrial.com BuyLog Catalog 20-33


Data subject to change
without notice
Uninterruptible Power Supplies Section 20
Digital Energy SG Series
10-150 kVA Three-Phase

SG Series 20-80 kVA UPS (Three-Phase)


Rating Parallel Input Output Dimensions Weight1 Product
Description (0.8 pf) Configuration Voltage Voltage (W x D X H) (lbs.) Number
20 kVA Three-Phase, 4W+G input & output,
20 kVA Single Module 277/480V 277/480V 27x32x71 745 UPS002SG444AN00
single module, 60 Hz
20 kVA Three-Phase, 4W+G input & output,
20 kVA Single Module 277/480V 277/480V 27x32x71 1914 UPSB02SG444AN00
single module, 60 Hz, 5 minute internal battery
20 kVA Three-Phase + EMI Filter (FCC Class A),
20 kVA Single Module 277/480V 277/480V 27x32x71 755 UPS002SG444AY00
4W+G input and output,single module, 60 Hz
20 kVA Three-Phase + EMI Filter (FCC Class A),
4W+G input and output, single module, 60 Hz, 20 kVA Single Module 277/480V 277/480V 27x32x71 1924 UPSB02SG444AY00
5 minute internal battery
20 kVA Three-Phase + EMI Filter (FCC Class A)
+ 5th Harmonic Filter, 4W+G input and output, 20 kVA Single Module 277/480V 277/480V 27x32x71 773 UPS002SG444AY50
single module, 60 Hz
20 kVA Three-Phase + EMI Filter (FCC Class A)
+ 5th Harmonic Filter, 4W+G input and output,
20 kVA Single Module 277/480V 277/480V 27x32x71 1942 UPSB02SG444AY50
single module, 60 Hz, 5 minute internal battery
20 kVA Three-Phase + 5th Harmonic Filter ,
20 kVA Single Module 277/480V 277/480V 27x32x71 763 UPS002SG444AN50
4W+G input and output, single module, 60 Hz
20 kVA Three-Phase + 5th Harmonic Filter ,
4W+G input and output, single module, 60 Hz, 20 kVA Single Module 277/480V 277/480V 27x32x71 1932 UPSB02SG444AN50
5 minute internal battery
30 kVA Three-Phase, 4W+G input & output,
30 kVA Single Module 277/480V 277/480V 27x32x71 952 UPS003SG444AN00
single module, 60 Hz
30 kVA Three-Phase + EMI Filter (FCC Class A),
30 kVA Single Module 277/480V 277/480V 27x32x71 962 UPS003SG444AY00
4W+G input and output, single module, 60 Hz
30 kVA Three-Phase + EMI Filter (FCC Class A)
+ 5th Harmonic Filter, 4W+G input and output, 30 kVA Single Module 277/480V 277/480V 27x32x71 980 UPS003SG444AY50
single module, 60 Hz
30 kVA Three-Phase + 5th Harmonic Filter,
30 kVA Single Module 277/480V 277/480V 27x32x71 970 UPS003SG444AN50
4W+G input and output, single module, 60 Hz
40 kVA Three-Phase, 4W +G input & output,
40 kVA Single Module 277/480V 277/480V 27x32x71 1127 UPS004SG444AN00
single module, 60 Hz
40 kVA Three-Phase + EMI Filter (FCC Class A),
40 kVA Single Module 277/480V 277/480V 27x32x71 1137 UPS004SG444AY00
4W+G input and output, single module, 60 Hz
40 kVA Three-Phase + EMI Filter (FCC Class A)
+ 5th Harmonic Filter, 4W+G input and output, 40 kVA Single Module 277/480V 277/480V 27x32x71 1159 UPS004SG444AY50
single module, 60 Hz
40 kVA Three-Phase + 5th Harmonic Filter ,
40 kVA Single Module 277/480V 277/480V 27x32x71 1147 UPS004SG444AN50
4W+G input and output, single module, 60 Hz
50 kVA Three-Phase, 4W+G input & output,
50 kVA Single Module 277/480V 277/480V 32x32x71 1230 UPS005SG444AN00
single module, 60 Hz
50 kVA Three-Phase + EMI Filter (FCC Class A),
50 kVA Single Module 277/480V 277/480V 32x32x71 1240 UPS005SG444AY00
4W+G input and output, single module, 60 Hz
50 kVA Three-Phase + EMI Filter (FCC Class A)
+ 5th Harmonic Filter, 4W+G input and output, 50 kVA Single Module 277/480V 277/480V 32x32x71 1267 UPS005SG444AY50
single module, 60 Hz
50 kVA Three-Phase + 5th Harmonic Filter,
50 kVA Single Module 277/480V 277/480V 32x32x71 1257 UPS005SG444AN50
4W+G input and output, single module, 60 Hz
80 kVA Three-Phase, 4W+G input & output,
80 kVA Single Module 277/480V 277/480V 32x32x71 1466 UPS008SG444AN00
single module, 60 Hz
80 kVA Three-Phase + EMI Filter (FCC Class A),
80 kVA Single Module 277/480V 277/480V 32x32x71 1476 UPS008SG444AY00
4W+G input and output, single module, 60 Hz
80 kVA Three-Phase + EMI Filter (FCC Class A)
+ 5th Harmonic Filter, 4W+G input and output, 80 kVA Single Module 277/480V 277/480V 32x32x71 1498 UPS008SG444AY50
single module, 60 Hz
80 kVA Three-Phase + 5th Harmonic Filter,
80 kVA Single Module 277/480V 277/480V 32x32x71 1488 UPS008SG444AN50
4W+G input and output, single module, 60 Hz
1Installed Weight. Note that shipping weight is higher.
Quotation must include cost for Commissioning Service (see SG Service).

20-34 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Uninterruptible Power Supplies Section 20
Digital Energy SG Series
10-150 kVA Three-Phase

SG Series 100-150 kVA UPS (Three-Phase)


Rating Parallel Input Output Dimensions Weight1 Product
Description (0.8 pf) Configuration Voltage Voltage (W x D X H) (lbs.) Number
100 kVA Three-Phase, 4W+G input & output,
100 kVA Single Module 277/480V 277/480V 47x32x71 1896 UPS010SG444AN00
single module, 60 Hz
100 kVA Three-Phase + EMI Filter,
100 kVA Single Module 277/480V 277/480V 47x32x71 1906 UPS010SG444AY00
4W+G input and output, single module, 60 Hz
100 kVA Three-Phase + EMI Filter
+ 5th Harmonic Filter, 4W+G input and output, 100 kVA Single Module 277/480V 277/480V 47x32x71 1939 UPS010SG444AY50
single module, 60 Hz
100 kVA Three-Phase + 5th Harmonic Filter,
100 kVA Single Module 277/480V 277/480V 47x32x71 1929 UPS010SG444AN50
4W+G input and output, single module, 60 Hz
120 kVA Three-Phase, 4W+G input & output,
120 kVA Single Module 277/480V 277/480V 47x32x71 1973 UPS012SG444AN00
single module, 60 Hz
120 kVA Three-Phase + EMI Filter,
120 kVA Single Module 277/480V 277/480V 47x32x71 1983 UPS012SG444AY00
4W+G input and output, single module, 60 Hz
120 kVA Three-Phase + EMI Filter (FCC Class A)
+ 5th Harmonic Filter, 4W+G input and output, 120 kVA Single Module 277/480V 277/480V 47x32x71 2017 UPS012SG444AY50
single module, 60 Hz
120 kVA Three-Phase + 5th Harmonic Filter ,
120 kVA Single Module 277/480V 277/480V 47x32x71 2007 UPS012SG444AN50
4W+G input and output, single module, 60 Hz
150 kVA Three-Phase, 4W+G input & output,
150 kVA Single Module 277/480V 277/480V 47x32x71 2128 UPS015SG444AN00
single module, 60 Hz
150 kVA Three-Phase + EMI Filter (FCC Class A),
150 kVA Single Module 277/480V 277/480V 47x32x71 2138 UPS015SG444AY00
4W+G input and output, single module, 60 Hz
150 kVA Three-Phase + EMI Filter (FCC Class A)
+ 5th Harmonic Filter, 4W+G input and output, 150 kVA Single Module 277/480V 277/480V 47x32x71 2181 UPS015SG444AY50
single module, 60 Hz
150 kVA Three-Phase + 5th Harmonic Filter,
150 kVA Single Module 277/480V 277/480V 47x32x71 2161 UPS015SG444AN50
4W+G input and output, single module, 60 Hz
1Installed Weight. Note that shipping weight is higher.
Quotation must include cost for Commissioning Service (see SG Service).

Rev. 11/13 www.geindustrial.com BuyLog Catalog 20-35


Data subject to change
without notice
Uninterruptible Power Supplies Section 20
Digital Energy SG Series
10-150 kVA Three-Phase
Battery Cabinets

SG Series 10 kVA - Battery Cabinets (matching)


10 Year Pro-Rated Battery Warranty
Approximate Run Times (minutes) Dimensions Weight Battery System Breaker Parallel Castor Kit
50% Load1 75% Load1 100% Load1 (H x W x D) (lbs.) Product Number Config. Strings P/N Suffix
105 61 42 71.3"x 27"x 31.9" 1255 SGA010-1-07-N 1 x 30A 1 C
182 105 72 71.3"x 27"x 31.9" 1566 SGA010-1-01-N 1 x 30A 1 C
303 181 127 71.3"x 27"x 31.9" 1917 SGA010-1-08-N 1 x 30A 1 C

SG Series 20 kVA - Battery Cabinets (matching)


10 Year Pro-Rated Battery Warranty
Approximate Run Times (minutes) Dimensions Weight Battery System Breaker Parallel Castor Kit
50% Load1 75% Load1 100% Load1 (H x W x D) (lbs.) Product Number Config. Strings P/N Suffix
42 23 14 71.3"x 27"x 31.9" 1250 SGA020-1-07-N 1 x 50A 1 C
73 43 29 71.3"x 27"x 31.9" 1566 SGA020-1-01-N 1 x 50A 1 C
150 88 60 71.3"x 27"x 31.9" 2663 SGA020-1-02-N 1 x 50A 1 C
215 128 85 71.3"x 27"x 31.9" 3067 SGA020-1-03-N 1 x 50A 1 C

SG Series 30 kVA - Battery Cabinets (matching)


10 Year Pro-Rated Battery Warranty
Approximate Run Times (minutes) Dimensions Weight Battery System Breaker Parallel Castor Kit
50% Load1 75% Load1 100% Load1 (H x W x D) (lbs.) Product Number Config. Strings P/N Suffix
23 11 7 71.3"x 27"x 31.9" 1255 SGA030-1-07-N 1 x 80A 1 C
43 26 17 71.3"x 27"x 31.9" 1566 SGA030-1-01-N 1 x 80A 1 C
72 43 29 71.3"x 27"x 31.9" 1917 SGA030-1-08-N 1 x 80A 1 C
130 74 54 71.3"x 27"x 31.9" 3528 SGA030-1-03-N 1 x 80A 1 C
277 172 107 71.3"x 27"x 31.9" 4679 SGA030-1-06-N 1 x 80A 1 C

SG Series 40kVA - Battery Cabinets (matching)


10 Year Pro-Rated Battery Warranty
Approximate Run Times (minutes) Dimensions Weight Battery System Breaker Parallel Castor Kit
50% Load1 75% Load1 100% Load1 (H x W x D) (lbs.) Product Number Config. Strings P/N Suffix
29 17 11 71.3"x 27"x 31.9" 1566 SGA040-1-01-N 1 x 100A 1 C
50 29 20 71.3"x 27"x 31.9" 1917 SGA040-1-08-N 1 x 100A 1 C
61 35 23 71.3"x 27"x 31.9" 2663 SGA040-1-02-N 1 x 100A 1 C
86 54 38 71.3"x 27"x 31.9" 3067 SGA040-1-03-N 1 x 100A 1 C
138 79 55 71.3"x 44"x 31.9" 4679 SGA040-1-05-N 1 x 100A 1 C

SG Series 50kVA - Battery Cabinets (matching)


10 Year Pro-Rated Battery Warranty
Approximate Run Times (minutes) Dimensions Weight Battery System Breaker Parallel Castor Kit
50% Load1 75% Load1 100% Load1 (H x W x D) (lbs.) Product Number Config. Strings P/N Suffix
23 13 8 71.3"x 27"x 31.9" 1566 SGA050-1-01-N 1 x 125A 1 C
38 22 14 71.3"x 27"x 31.9" 1917 SGA050-1-08-N 1 x 125A 1 C
65 42 29 71.3"x 27"x 31.9" 3067 SGA050-1-03-N 1 x 125A 1 C
150 77 61 71.3"x 44"x 31.9" 4679 SGA050-1-06-N 1 x 125A 1 C
10.8 pF
All run times listed above are based on the manufacturers published data, and do not include connector and wiring losses.
These run times are approximate and are intended for use as a guide only. Consult factory for guaranteed run times.
All cabinets contain Flame Retardant Batteries.
480 Vdc Nominal - 240 cells - 1.67 Final Volts per Cell, except 1.75 Final Volts per Cell over 60 minutes.
Prices above include internally mounted circuit breaker(s) sized for the UPS at 100% load. See "Breaker Configuration" column in tables above.
An external, user supplied junction panel is required when multiple battery systems are to be connected to a single UPS.
Each string, in multi-string systems, is individually fused.

20-36 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Uninterruptible Power Supplies Section 20
Digital Energy SG Series
10-150 kVA Three-Phase
Battery Cabinets

SG Series 80kVA - Battery Cabinets (matching)


10 Year Pro-Rated Battery Warranty
Approximate Run Times (minutes) Dimensions Weight Battery System Breaker Parallel Castor Kit
50% Load1 75% Load1 100% Load1 (H x W x D) (lbs.) Product Number Config. Strings P/N Suffix
20 11 5 71.3"x 27"x 31.5" 1917 SGA080-1-08-N 1 x 200A 1 C
39 22 15 71.3"x 27"x 31.5" 3067 SGA080-1-03-N 1 x 200A 1 C
70 49 33 71.3"x 44"x 31.5" 4679 SGA080-1-06-N 1 x 200A 1 C
139 79 55 71.3"x 88"x 31.5" 7864 SGA080-2-05-N 1 x 200A 2 C
232 139 93 71.3 x 132"x 31.5" 11796 SGA080-3-05-N 1 x 200A 3 C

SG Series 100kVA - Battery Cabinets (matching)


10 Year Pro-Rated Battery Warranty
Approximate Run Times (minutes) Dimensions Weight Battery System Breaker Parallel Castor Kit
50% Load1 75% Load1 100% Load1 (H x W x D) (lbs.) Product Number Config. Strings P/N Suffix
29 16 10 71.3"x 27"x 31.5" 3067 SGA100-1-03-N 1 x 250A 1 C
41 24 16 71.3"x 44"x 31.5" 3932 SGB100-1-05-N 1 x 250A 1 C
61 36 25 71.3"x 44"x 31.5" 4679 SGB100-1-06-N 1 x 250A 1 C
149 76 61 71.3"x 88"x 31.5" 9358 SGB100-2-06-N 1 x 250A 2 C
257 149 93 71.3"x 132"x 31.5" 14037 SGB100-3-06-N 1 x 250A 3 C

SG Series 120kVA - Battery Cabinets (matching)


Pro-Rated Battery Warranty
Approximate Run Times (minutes) Dimensions Weight Battery System Breaker Parallel Castor Kit
50% Load1 75% Load1 100% Load1 (H x W x D) (lbs.) Product Number Config. Strings P/N Suffix
22 12 6 71.3"x 27"x 31.5" 3067 SGA120-1-03-N 1 x 300A 1 C
32 18 12 71.3"x 44"x 31.5" 3932 SGB120-1-05-N 1 x 300A 1 C
49 28 19 71.3"x 44"x 31.5" 4679 SGB120-1-06-N 1 x 300A 1 C
139 79 55 71.3"x 132"x 31.5" 11796 SGB120-3-05-N 1 x 300A 3 C
200 120 79 71.3"x 176"x 31.5" 15728 SGB120-4-05-N 1 x 300A 4 C
279 173 109 71.3"x 176"x 31.5" 18716 SGB120-4-06-N 1 x 300A 4 C

SG Series 150kVA - Battery Cabinets (matching)


10 Year Pro-Rated Battery Warranty
Approximate Run Times (minutes) Dimensions Weight Battery System Breaker Parallel Castor Kit
50% Load1 75% Load1 100% Load1 (H x W x D) (lbs.) Product Number Config. Strings P/N Suffix
19 10 5 71.3"x 27"x 31.5" 3528 SGA150-1-04-N 1 x 400A 1 C
24 13 7 71.3"x 44"x 31.5" 3932 SGB150-1-05-N 1 x 400A 1 C
36 21 14 71.3"x 44"x 31.5" 4679 SGB150-1-06-N 1 x 400A 1 C
59 35 24 71.3"x 88"x 31.5" 7864 SGB150-2-05-N 1 x 400A 2 C
148 76 60 71.3"x 132"x 31.5" 14037 SGB150-3-06-N 1 x 400A 3 C
217 125 76 71.3"x 176"x 31.5" 18716 SGB150-4-06-N 1 x 400A 4 C
10.8 pF
All run times listed above are based on the manufacturers published data, and do not include connector and wiring losses.
These run times are approximate and are intended for use as a guide only. Consult factory for guaranteed run times.
All cabinets contain Flame Retardant Batteries.
480 Vdc Nominal - 240 cells - 1.67 Final Volts per Cell, except 1.75 Final Volts per Cell over 60 minutes.
Prices above include internally mounted circuit breaker(s) sized for the UPS at 100% load. See "Breaker Configuration" column in tables above.
An external, user supplied junction panel is required when multiple battery systems are to be connected to a single UPS.
Each string, in multi-string systems, is individually fused.

Rev. 11/13 www.geindustrial.com BuyLog Catalog 20-37


Data subject to change
without notice
Uninterruptible Power Supplies Section 20
Digital Energy SG Series
10-150 kVA Three-Phase
Transformers

SG Series 10-20 kVA Input / Output Transformers (non-matching)


Voltage kVA Dimensions (inches) Weight Product
Rating Rating Height Width Depth (lbs) Number
10 kVA 208 -480 Y 30 32.25 24 18.07 300 U9T83B3802
Non Shielded Aluminum Windings
Input 480 -480 Y 30 32.25 24 18.07 300 U9T83B3852
10 kVA 480 -208 Y 15 32.25 24 18.07 300 U9T83B3872
Non Shielded Aluminum Windings
Output 480 -480 Y 15 32.25 24 18.07 300 U9T83B3852
20 kVA 208 -480 Y 45 32.25 24 18.07 365 U9T83B3803
Non Shielded Aluminum Windings
Input 480 -480 Y 45 32.25 24 18.07 365 U9T83B3853
20 kVA 480 -208 Y 30 32.25 24 18.07 300 U9T83B3872
Non Shielded Aluminum Windings
Output 480 -480 Y 30 32.25 24 18.07 300 U9T83B3852

SG Series 30-40 kVA Input / Output Transformers (non-matching)


Voltage kVA Dimensions (inches) Weight Product
Rating Rating Height Width Depth (lbs) Number
30 kVA 208 -480 Y 75 35.75 32 23.69 505 U9T83B3804
Non Shielded Aluminum Windings
Input 480 -480 Y 75 35.75 32 23.69 505 U9T84B3854
30 kVA 480 -208 Y 45 32.25 24 18.07 365 U9T83B3873
Non Shielded Aluminum Windings
Output 480 -480 Y 45 32.25 24 18.07 365 U9T83B3853
40 kVA 208 -480 Y 75 35.75 32 23.69 505 U9T83B3804
Non Shielded Aluminum Windings
Input 480 -480 Y 75 35.75 32 23.69 505 U9T84B3854
40 kVA 480 -208 Y 75 35.75 32 23.69 505 U9T83B3874
Non Shielded Aluminum Windings
Output 480 -480 Y 75 35.75 32 23.69 505 U9T84B3854

SG Series 50-80 kVA Input / Output Transformers (non-matching)


Voltage kVA Dimensions (inches) Weight Product
Rating Rating Height Width Depth (lbs) Number
50 kVA 208 -480 Y 75 35.75 32 23.69 505 U9T83B3804
Non Shielded Aluminum Windings
Input 480 -480 Y 75 35.75 32 23.69 505 U9T84B3854
50 kVA 480 -208 Y 75 35.75 32 23.69 505 U9T83B3874
Non Shielded Aluminum Windings
Output 480 -480 Y 75 35.75 32 23.69 505 U9T84B3854
80 kVA 208 -480 Y 150 46 35 23.69 775 U9T83B3806
Non Shielded Aluminum Windings
Input 480 -480 Y 150 46 35 23.69 775 U9T83B3836
80 kVA 480 -208 Y 150 46 35 23.69 775 U9T83B3876
Non Shielded Aluminum Windings
Output 480 -480 Y 150 46 35 23.69 775 U9T83B3856

SG Series 100-120 kVA Input / Output Transformers (non-matching)


Voltage kVA Dimensions (inches) Weight Product
Rating Rating Height Width Depth (lbs) Number
100 kVA 208 -480 Y 150 46 35 23.69 775 U9T83B3806
Non Shielded Aluminum Windings
Input 480 -480 Y 150 46 35 23.69 775 U9T83B3856
100 kVA 480 -208 Y 150 46 35 23.69 775 U9T83B3876
Non Shielded Aluminum Windings
Output 480 -480 Y 150 46 35 23.69 775 U9T83B3856
120 kVA 208 -480 Y 225 48 38.5 28.94 1030 U9T83B3807
Non Shielded Aluminum Windings
Input 480 -480 Y 225 48 38.5 28.94 1030 U9T83B3857
120 kVA 480 -208 Y 225 48 38.5 28.94 1030 U9T83B3877
Non Shielded Aluminum Windings
Output 480 -480 Y 225 48 38.5 28.94 1030 U9T83B3857

SG Series 150 kVA Input / Output Transformers (non-matching)


Voltage kVA Dimensions (inches) Weight Product
Rating Rating Height Width Depth (lbs) Number
150 kVA 208 -480 Y 225 48 38.5 28.94 1030 U9T83B3807
Non Shielded Aluminum Windings
Input 480 -480 Y 225 48 38.5 28.94 1030 U9T83B3857
150 kVA 208 -480 Y 225 48 38.5 28.94 1030 U9T83B3877
Non Shielded Aluminum Windings
Output 480 -480 Y 225 48 38.5 28.94 1030 U9T83B3857

20-38 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Uninterruptible Power Supplies Section 20
Digital Energy SG Series
10-150 kVA Three-Phase
Bypass Panels

SG Series 10-150 kVA External Bypass Panels (non-matching)


Stand-alone, single module systems
UPS Breaker Key Interrupt Dimensions (inches) Weight1 Product
Rating Configuration Interlocks Rating Height Width Depth (lbs.) Number
2-breaker No 14kAIC 49.38 31 11.5 178 GS20015-00000-A0S
3-breaker No 14kAIC 65.88 31 11.5 280 GS20015-10025-A0S
2-breaker Yes 14kAIC 57.63 31 14 260 GS20015-00000-A1S
3-breaker Yes 14kAIC 78.25 31 14 382 GS20015-10025-A1S
10 kVA
2-breaker No 65kAIC 49.38 31 11.5 178 GS20015-00000-A0H
3-breaker No 65kAIC 65.88 31 11.5 280 GS20015-10025-A0H
2-breaker Yes 65kAIC 57.63 31 14 260 GS20015-00000-A1H
3-breaker Yes 65kAIC 78.25 31 14 382 GS20015-10025-A1H
2-breaker No 14kAIC 49.38 31 11.5 178 GS20030-00000-A0S
3-breaker No 14kAIC 65.88 31 11.5 280 GS20030-10050-A0S
2-breaker Yes 14kAIC 57.63 31 14 260 GS20030-00000-A1S
3-breaker Yes 14kAIC 78.25 31 14 382 GS20030-10050-A1S
20 kVA
2-breaker No 65kAIC 49.38 31 11.5 178 GS20030-00000-A0H
3-breaker No 65kAIC 65.88 31 11.5 280 GS20030-10050-A0H
2-breaker Yes 65kAIC 57.63 31 14 260 GS20030-00000-A1H
3-breaker Yes 65kAIC 78.25 31 14 382 GS20030-10050-A1H
2-breaker No 14kAIC 49.38 31 11.5 178 GS20050-00000-A0S
3-breaker No 14kAIC 65.88 31 11.5 280 GS20050-10070-A0S
2-breaker Yes 14kAIC 57.63 31 14 260 GS20050-00000-A1S
3-breaker Yes 14kAIC 78.25 31 14 382 GS20050-10070-A1S
30 kVA
2-breaker No 65kAIC 49.38 31 11.5 178 GS20050-00000-A0H
3-breaker No 65kAIC 65.88 31 11.5 280 GS20050-10070-A0H
2-breaker Yes 65kAIC 57.63 31 14 260 GS20050-00000-A1H
3-breaker Yes 65kAIC 78.25 31 14 382 GS20050-10070-A1H
2-breaker No 14kAIC 49.38 31 11.5 178 GS20060-00000-A0S
3-breaker No 14kAIC 65.88 31 11.5 280 GS20060-10080-A0S
2-breaker Yes 14kAIC 57.63 31 14 260 GS20060-00000-A1S
3-breaker Yes 14kAIC 78.25 31 14 382 GS20060-10080-A1S
40 kVA
2-breaker No 65kAIC 49.38 31 11.5 178 GS20060-00000-A0H
3-breaker No 65kAIC 65.88 31 11.5 280 GS20060-10080-A0H
2-breaker Yes 65kAIC 57.63 31 14 260 GS20060-00000-A1H
3-breaker Yes 65kAIC 78.25 31 14 382 GS20060-10080-A1H
2-breaker No 35kAIC 49.38 31 11.5 178 GS20080-00000-A0S
3-breaker No 35kAIC 65.88 31 11.5 280 GS20080-10125-A0S
50 kVA
2-breaker Yes 35kAIC 57.63 31 14 260 GS20080-00000-A1S
3-breaker Yes 35kAIC 78.25 31 14 382 GS20080-10125-A1S
2-breaker No 35kAIC 49.38 31 11.5 178 GS20125-00000-A0S
3-breaker No 35kAIC 65.88 31 11.5 280 GS20125-10175-A0S
80 kVA
2-breaker Yes 35kAIC 57.63 31 14 260 GS20125-00000-A1S
3-breaker Yes 35kAIC 78.25 31 14 382 GS20125-10175-A1S
2-breaker No 35kAIC 49.38 31 11.5 178 GS20150-00000-A0S
3-breaker No 35kAIC 65.88 31 11.5 280 GS20150-10200-A0S
100 kVA
2-breaker Yes 35kAIC 57.63 31 14 260 GS20150-00000-A1S
3-breaker Yes 35kAIC 78.25 31 14 382 GS20150-10200-A1S
2-breaker No 35kAIC 49.38 31 11.5 178 GS20200-00000-A0S
3-breaker No 35kAIC 65.88 31 11.5 280 GS20200-10250-A0S
120 kVA
2-breaker Yes 35kAIC 57.63 31 14 260 GS20200-00000-A1S
3-breaker Yes 35kAIC 78.25 31 14 382 GS20200-10250-A1S
2-breaker No 35kAIC 49.38 40 11.5 221 GS20250-00000-A0S
3-breaker No 35kAIC 70 40 11.5 405 GS20250-10300-A0S
150 kVA
2-breaker Yes 35kAIC 61.75 40 14 290 GS20250-00000-A1S
3-breaker Yes 35kAIC 86.5 40 14 500 GS20250-10300-A1S
1Installed Weight. Note that shipping weight is higher.

Rev. 11/13 www.geindustrial.com BuyLog Catalog 20-39


Data subject to change
without notice
Uninterruptible Power Supplies Section 20
Digital Energy SG Series
225-300 kVA Three-Phase

Technical Specifications-UL approved


Topology True on-line, double conversion (VFI) with integral static switch and internal maintenance bypass
Technology Advanced IGBT with SVM strategy, microprocessor and DSP controlled at optimal switching frequency
Operating Modes True on-line double conversion, automatic bypass, frequency converter, RPA up to eight units

Output Power Rating kVA


(at PF=0.60.8 lag) 225 300
Output Power Rating (kW) 203 270
Weight w/o Batteries (lbs) 3086 3086
Dimensions WxDxH (inches) 65x32x71
Noise Level dB(A) <67 dB
Input Voltage (VAC) 3x480/277 + Neutral ( -20% to +15% without battery discharge)
Input Frequency 60/50 Hz +/-10%
Output Voltage (sinusoidal) (VAC) 3x480/277 + Neutral
Output Frequency 60/50 Hz +/-0.01%
Output THD at Linear Load <2%
Output THD at Non-linear Load <3%
Crest Factor 3:1
Overload Capability on Inverter 125% 10 min., 150% 30 seconds
Overload Capability on Automatic Bypass 200% 5 min., 110% continuously
Output Voltage Regulation
Static +/- 1%
0-100% Step Load +/- 3%
Overall Efficiency at 100% Load 93%
Ambient Operating Temperature 32-104F (0-40C)
Color Black
Classifications and Listing UL1778/IP20/NEMA-PE-1/ISO9001
RFI and Surge Protection EN 50091-2 / IEC 62040-2 / IEEE 587 B / FCC Class A compliance1
Standard Connectivity RS232; programmable alarm contacts; SNMP (optional)
Warranty 12 months
1FCC compliance feature available as an option.
Specifications subject to change without notice.

SG Series 225-300 kVA UPS (Three-Phase)


Rating Parallel Input Output Dimensions Weight2 Product
Description (0.8 pf) Configuration Voltage Voltage (W x D X H) (lbs.) Number
225 kVA Three-Phase, 4W+G input & output,
225 kVA Single Module 277/480V 277/480V 65x32x71 3200 UPS022SG444AN00
single module, 60 Hz
225 kVA Three-Phase + EMI Filter (FCC Class A),
225 kVA Single Module 277/480V 277/480V 65x32x71 3325 UPS022SG444AY00
4W+G input and output,single module, 60 Hz
225 kVA Three-Phase + EMI Filter (FCC Class A)
+ 5th Harmonic Filter, 4W+G input and output, 225 kVA Single Module 277/480V 277/480V 65x32x71 3425 UPS022SG444AY50
single module, 60 Hz
225 kVA Three-Phase + 5th Harmonic Filter,
225 kVA Single Module 277/480V 277/480V 65x32x71 3300 UPS022SG444AN50
4W+G input and output, single module, 60 Hz
225 kVA Three-Phase, 3W+G input & output,
225 kVA Single Module 277/480V 277/480V 65x32x71 3200 UPS022SG443AN00
single module, 60 Hz
225 kVA Three-Phase + EMI Filter (FCC Class A),
225 kVA Single Module 277/480V 277/480V 65x32x71 3325 UPS022SG443AY00
3W+G input and output, single module, 60 Hz
225 kVA Three-Phase + EMI Filter (FCC Class A)
+ 5th Harmonic Filter, 3W+G input and output, 225 kVA Single Module 277/480V 277/480V 65x32x71 3425 UPS022SG443AY50
single module, 60 Hz
225 kVA Three-Phase + 5th Harmonic Filter,
225 kVA Single Module 277/480V 277/480V 65x32x71 3300 UPS022SG443AN50
3W+G input and output, single module, 60 Hz
300 kVA Three-Phase, 4W+G input & output,
300 kVA Single Module 277/480V 277/480V 65x32x71 3400 UPS030SG444AN00
single module, 60 Hz
300 kVA Three-Phase + EMI Filter (FCC Class A),
300 kVA Single Module 277/480V 277/480V 65x32x71 3550 UPS030SG444AY00
4W+G input and output, single module, 60 Hz
300 kVA Three-Phase + EMI Filter (FCC Class A)
+ 5th Harmonic Filter, 4W+G input and output, 300 kVA Single Module 277/480V 277/480V 65x32x71 3500 UPS030SG444AY50
single module, 60 Hz
300 kVA Three-Phase + 5th Harmonic Filter,
300 kVA Single Module 277/480V 277/480V 65x32x71 3650 UPS030SG444AN50
4W+G input and output, single module, 60 Hz
300 kVA Three-Phase, 3W+G input & output,
300 kVA Single Module 277/480V 277/480V 65x32x71 3400 UPS030SG443AN00
single module, 60 Hz
300 kVA Three-Phase + EMI Filter (FCC Class A),
300 kVA Single Module 277/480V 277/480V 65x32x71 3550 UPS030SG443AY00
3W+G input and output, single module, 60 Hz
300 kVA Three-Phase + EMI Filter (FCC Class A)
+ 5th Harmonic Filter, 3W+G input and output, 300 kVA Single Module 277/480V 277/480V 65x32x71 3500 UPS030SG443AY50
single module, 60 Hz
300 kVA Three-Phase + 5th Harmonic Filter,
300 kVA Single Module 277/480V 277/480V 65x32x71 3650 UPS030SG443AN50
3W+G input and output, single module, 60 Hz
2Installed Weight. Note that shipping weight is higher.

20-40 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Uninterruptible Power Supplies Section 20
Digital Energy SG Series
225-300 kVA Three-Phase
Battery Cabinets

SG Series 225kVA - Battery Cabinets (matching)


10 Year Pro-Rated Battery Warranty
Approximate Run Times (minutes) Dimensions Weight Battery System Breaker Parallel Castor Kit
50% Load1 75% Load1 100% Load1 (H x W x D) (lbs.) Product Number Config. Strings P/N Suffix
24 13 8 71.3"x 54"x 31.5" 6134 SGA225-2-03-N 2 x 300A 2 C
28 16 10 71.3"x 54"x 31.5" 7056 SGA225-2-04-N 2 x 300A 2 C
35 20 13 71.3"x 88"x 31.5" 7864 SGA225-2-05-N 1 x 600A 2 C
76 53 36 71.3"x 132"x 31.5" 14037 SGB225-3-06-N 1 x 600A 3 C
126 67 53 71.3"x 176"x 31.5" 18716 SGB225-4-06-N 1 x 600A 4 C
217 126 76 71.3"x 264"x 31.5" 28074 SGB225-6-06-N 1 x 600A 6 C

SG Series 300kVA - Battery Cabinets (matching)


10 Year Pro-Rated Battery Warranty
Approximate Run Times (minutes) Dimensions Weight Battery System Breaker Parallel Castor Kit
50% Load1 75% Load1 100% Load1 (H x W x D) (lbs.) Product Number Config. Strings P/N Suffix
19 10 5 71.3"x 54"x 31.5" 7056 SGA300-2-04-N 2 x 400A 2 C
36 21 14 71.3"x 88"x 31.5" 9358 SGB300-2-06-N 1 x 800A 2 C
41 24 15 71.3"x 132"x 31.5" 11796 SGB300-3-05-N 1 x 800A 3 C
76 53 36 71.3"x 176"x 31.5" 18716 SGB300-4-06-N 1 x 800A 5 C
107 65 49 71.3"x 220"x 31.5" 23395 SGB300-5-06-N 1 x 800A 4 C
148 76 60 71.3"x 264"x 31.5" 28074 SGB300-6-06-N 1 x 800A 6 C
10.8 pF
All run times listed above are based on the manufacturers published data, and do not include connector and wiring losses.
These run times are approximate and are intended for use as a guide only. Consult factory for guaranteed run times.
All cabinets contain Flame Retardant Batteries.
480 Vdc Nominal - 240 cells - 1.67 Final Volts per Cell, except 1.75 Final Volts per Cell over 60 minutes.
Prices above include internally mounted circuit breaker(s) sized for the UPS at 100% load. See "Breaker Configuration" column in tables above.
An external, user supplied junction panel is required when multiple battery systems are to be connected to a single UPS.
Each string, in multi-string systems, is individually fused.

Rev. 11/13 www.geindustrial.com BuyLog Catalog 20-41


Data subject to change
without notice
Uninterruptible Power Supplies Section 20
Digital Energy SG Series
225-300 kVA Three-Phase
Transformers, Bypass Panels

SG Series 225-300 kVA Input / Output Transformers (non-matching)


Voltage kVA Dimensions (inches) Weight Product
Rating Rating Height Width Depth (lbs) Number
225 kVA 208 -480 Y 500 59 43.5 38.5 2800 UNMK500BK
Non Shielded Aluminum Windings
Input 480 -480 Y 500 59 43.5 38.5 2800 UNMK500KK
225 kVA 480 -208 Y 500 59 43.5 38.5 2800 UMNK500KB
Non Shielded Aluminum Windings
Output 480 -480 Y 500 59 43.5 38.5 2800 UMNK500KK
300 kVA 208 -480 Y 500 59 43.5 38.5 2800 UMNK500BK
Non Shielded Aluminum Windings
Input 480 -480 Y 500 59 43.5 38.5 2800 UMNK500KK
300 kVA 480 -208 Y 500 59 43.5 38.5 2800 UMNK500KB
Non Shielded Aluminum Windings
Output 480 -480 Y 500 59 43.5 38.5 2800 UMNK500KK

SG Series 225-300 kVA External Bypass Panels (non-matching)


Stand-alone, single module systems
UPS Breaker Key Interrupt Dimensions (inches) Weight1 Product
Rating Configuration Interlocks Rating Height Width Depth (lbs.) Number
2-breaker No 35kAIC 53.5 40 11.5 288 GS20350-00000-A0S
3-breaker No 35kAIC 82.38 40 11.5 471 GS20350-10450-A0S
225kVA
2-breaker Yes 35kAIC 65.88 40 14 360 GS20350-00000-A1S
3-breaker Yes 35kAIC 90.63 40 14 557 GS20350-10450-A1S
2-breaker No 35kAIC 53.5 40 11.5 288 GS20500-00000-A0S
3-breaker No 35kAIC 82.38 40 11.5 471 GS20500-10600-A0S
300kVA
2-breaker Yes 35kAIC 65.88 40 14 360 GS20500-00000-A1S
3-breaker Yes 35kAIC 90.63 40 14 557 GS20500-10600-A1S
1Installed Weight. Note that shipping weight is higher.

20-42 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Uninterruptible Power Supplies Section 20
Digital Energy SG Series
400-500 kVA Three-Phase

Technical Specifications-UL approved


Topology True on-line, double conversion (VFI) with integral static switch and internal maintenance bypass
Technology Advanced IGBT with SVM strategy, microprocessor and DSP controlled at optimal switching frequency
Operating Modes True on-line double conversion, automatic bypass, frequency converter, RPA up to eight units

Output Power Rating kVA


(at PF=0.60.9 lag) 400 500
Weight w/o Batteries (lbs) 4600 5100
Output Power Rating (kW) 360 450
Overload Capability on Inverter 125% 10 min., 150% 30 sec. 125% 10 min., 150% 30 sec.
Noise Level dB(A) <65 dB
Input Voltage (VAC) 3x480/277 + Neutral ( -20% to +15% without battery discharge)
Input Frequency 60/50 Hz +/-10%
Output Voltage (sinusoidal) (VAC) 3x480/277 + Neutral
Output Frequency 60/50 Hz +/-0.01%
Output THD at Linear Load <2%
Output THD at Non-linear Load <3%
Crest Factor 3:1
Overload Capability on Automatic Bypass 200% 5 min., 110% continuously
Output Voltage Regulation
Static +/- 1%
0-100% Step Load +/- 3%
Overall Efficiency at 100% Load 94%
Ambient Operating Temperature 32-104F (0-40C)
Color Black
Classifications and Listing UL1778/IP20/NEMA-PE-1/ISO9001
RFI and Surge Protection EN 50091-2 / IEC 62040-2 / IEEE 587 B / FCC Class A compliance1
Standard Connectivity RS232; programmable alarm contacts; SNMP (optional)
Warranty 12 months
1FCC compliance feature available as an option.
Specifications subject to change without notice.

SG Series 400-500 kVA UPS (Three-Phase)


Rating Parallel Input Output Dimensions Weight2 Product
Description (0.8 pf) Configuration Voltage Voltage (W x D X H) (lbs.) Number
400 kVA Three-Phase, 4W+G input & output,
400 kVA Single Module 277/480V 277/480V 81x32.5x77 4410 UPS040SG444AN00
single module, 60 Hz
400 kVA Three-Phase + 5th Harmonic Filter,
400 kVA Single Module 277/480V 277/480V 81x32.5x77 4631 UPS040SG444AN50
4W+G input and output, single module, 60 Hz
400 kVA Three-Phase + 5th & 11th Harmonic Filters,
400 kVA Single Module 277/480V 277/480V 81x32.5x77 4631 UPS040SG444ANE0
4W+G input and output, single module, 60 Hz
400 kVA Three-Phase, 3W+G input & output,
400 kVA Single Module 277/480V 277/480V 81x32.5x77 4410 UPS040SG443AN00
single module, 60 Hz
400 kVA Three-Phase + 5th Harmonic Filter,
400 kVA Single Module 277/480V 277/480V 81x32.5x77 4631 UPS040SG443AN50
3W+G input and output, single module, 60 Hz
400 kVA Three-Phase + 5th & 11th Harmonic Filters,
400 kVA Single Module 277/480V 277/480V 81x32.5x77 4631 UPS040SG443ANE0
3W+G input and output, single module, 60 Hz
500 kVA Three-Phase, 4W+G input & output,
500 kVA Single Module 277/480V 277/480V 81x32.5x77 4851 UPS050SG444AN00
single module, 60 Hz
500 kVA Three-Phase + 5th Harmonic Filter,
500 kVA Single Module 277/480V 277/480V 81x32.5x77 5072 UPS050SG444AN50
4W+G input and output, single module, 60 Hz
500 kVA Three-Phase + 5th & 11th Harmonic Filters,
500 kVA Single Module 277/480V 277/480V 81x32.5x77 5072 UPS050SG444ANE0
4W+G input and output, single module, 60 Hz
500 kVA Three-Phase, 3W+G input & output,
500 kVA Single Module 277/480V 277/480V 81x32.5x77 4851 UPS050SG443AN00
single module, 60 Hz
500 kVA Three-Phase + 5th Harmonic Filter,
500 kVA Single Module 277/480V 277/480V 81x32.5x77 5072 UPS050SG443AN50
3W+G input and output, single module, 60 Hz
500 kVA Three-Phase + 5th & 11th Harmonic Filters,
500 kVA Single Module 277/480V 277/480V 81x32.5x77 5072 UPS050SG443ANE0
3W+G input and output, single module, 60 Hz
2Installed Weight. Note that shipping weight is higher.
Quotation must include cost for Commissioning Service (see SG Service).

Rev. 11/13 www.geindustrial.com BuyLog Catalog 20-43


Data subject to change
without notice
Uninterruptible Power Supplies Section 20
Digital Energy SG Series
400-500 kVA Three-Phase
Battery Cabinets, Transformers, Bypass Panels

SG Series 400 kVA - Battery Cabinets (non-matching)


10 Year Pro-Rated Battery Warranty
Approximate Run Times (minutes) Dimensions Weight Battery System Breaker Parallel Castor Kit
50% Load1 75% Load1 100% Load1 (H x W x D) (lbs.) Product Number Config. Strings P/N Suffix
25 14 8 71.3"x 88"x 31.5" 9358 SGB400-2-06-N 2 x 500A 2 C
28 16 10 71.3"x 132"x 31.5" 11796 SGB400-3-05-N 3 x 400A 3 C
42 24 16 71.3"x 176"x 31.5" 15728 SGB400-4-05-N 4 x 400A 4 C
71 50 33 71.3"x 220"x 31.5" 23395 SGB400-5-06-N 4 x 400A 5 C
94 61 43 71.3"x 264"x 31.5" 28074 SGB400-6-06-N 6 x 400A 6 C

SG Series 500 kVA - Battery Cabinets (non-matching)


10 Year Pro-Rated Battery Warranty
Approximate Run Times (minutes) Dimensions Weight Battery System Breaker Parallel Castor Kit
50% Load1 75% Load1 100% Load1 (H x W x D) (lbs.) Product Number Config. Strings P/N Suffix
15 7 4 88" x 31.5" x 71.3" 9400 SGB500-2-06-N 2 x 600A 2 C
17 9 4 132" x 31.5" x 71.3" 11796 SGB500-3-05-N 3 x 400A 3 C
21 11 6 125" x 31.5" x 71.3" 14111 SGC500-4-04-N 4 x 400A 4 C
26 14 9 176 x 31.5" x 71.3" 15728 SGB500-4-05-N 4 x 400A 4 C
39 23 15 176 x 31.5" x 71.3" 18716 SGB500-4-06-N 4 x 400A 4 C
54 31 22 220" x 31.5" x 71.3" 23395 SGB500-5-06-N 5 x 400A 5 C
63 39 27 264" x 31.5" x 71.3" 28074 SGB500-6-06-N 6 x 400A 6 C
10.8 pF
20.9 pF
3Optional 5-year, full replacement warranty does not include labor or freight. Total warranty period is 5 years.
All run times listed above are based on the manufacturers published data, and do not include connector and wiring losses.
These run times are approximate and are intended for use as a guide only. Consult factory for guaranteed run times.
All cabinets contain Flame Retardant Batteries.
480 Vdc Nominal - 240 cells - 1.67 Final Volts per Cell, except 1.75 Final Volts per Cell over 60 minutes.
Prices above include internally mounted circuit breaker(s) sized for the UPS at 100% load. See "Breaker Configuration" column in tables above.
An external, user supplied junction panel is required when multiple battery systems are to be connected to a single UPS.
Each string, in multi-string systems, is individually fused.
These cabinets utilize batteries manufactured by Power Battery Company, Inc. and carry a standard 10-year, pro-rated warranty.
(Labor and freight not included.)

SG Series 400-500 kVA Input / Output Transformers (non-matching)


Voltage kVA Dimensions (inches) Weight Product
Rating Rating Height Width Depth (lbs) Number
400 kVA 208-480 Y 750 66 51.5 43.5 4200 UNMK750BK
Non Shielded Aluminum Windings
Input 480-480 Y 750 66 51.5 43.5 4200 UNMK750KK
400 kVA 480-208 Y 750 66 51.5 43.5 4200 UMNK750KB
Non Shielded Aluminum Windings
Output 480-480 Y 750 66 51.5 43.5 4200 UMNK750KK
500 kVA 208-480 Y 750 66 51.5 43.5 4200 UMNK750BK
Non Shielded Aluminum Windings
Input 480-480 Y 750 66 51.5 43.5 4200 UMNK750KK
500 kVA 480-208 Y 750 66 51.5 43.5 4200 UMNK750KB
Non Shielded Aluminum Windings
Output 480-480 Y 750 66 51.5 43.5 4200 UMNK750KK

SG Series 400-500 kVA External Bypass Panels (non-matching)


Stand-alone, single module systems
UPS Breaker Key Interrupt Dimensions (inches) Weight4 Product
Rating Configuration Interlocks Rating Height Width Depth (lbs.) Number
2-breaker No 50kAIC 70 40 11.5 288 GS20600-00000-A0S
3-breaker No 50kAIC 90.63 40 11.5 500 GS20600-10800-A0S
400kVA
2-breaker Yes 50kAIC 82.38 40 14 416 GS20600-00000-A1S
3-breaker Yes 50kAIC 90.63 40 14 557 GS20600-10800-A1S
2-breaker No 50kAIC 74.13 40 11.5 335 GS20800-00000-A0S
3-breaker No 50kAIC 90.63 40 11.5 583 GS20800-11000-A0S
500kVA
2-breaker Yes 50kAIC 90.63 40 14 416 GS20800-00000-A1S
3-breaker Yes 50kAIC 90.63 40 14 608 GS20800-11000-A1S
4Installed Weight. Note that shipping weight is higher.

20-44 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Uninterruptible Power Supplies Section 20
Digital Energy SG Series
SG Software and Connectivity Products

SG Software/Monitoring
Description Product Number
Advanced SNMP/Web interface card, UTP/BNC UPS11701
Remote Status Panel (includes APS) UPS11785
Customer Interface Card (CIC) - six programmable relay contacts UPS1006691
External SNMP Interface Box (requires LincBox Protocol Converter) UPS1009223
LincBox (CP4) Protocol Converter (uses RS-232 connection to UPS) UPS11483
Modbus RTU RS232 UPS16276
Modbus RTU RS485 UPS16275
RS232 to RS485/422 Converter UPS11227

Hardware
Description Product Number
Intelligent Sync Module
This module sync's two parallel systems together to allow the outputs to switch in-Phase with a static switch. UPS16274

IRIS Services
Description Product Number
IRIS starter kit for LanPro1 IRLP
IRIS starter kit for SP/SG/LP33U S/P 10-40kVA1 IRSP04
IRIS starter kit for SP/SG/LP33U S/P 60-120kVA1 IRSP12
IRIS starter kit for SP/SG/LP33U S/P 150-550kVA1 IRSP50
IRIS yearly fee after 1st year for LP11U2 FIRLP
IRIS yearly fee after 1st year for SP/SG/LP33U S/P 10-40kVA2 FIRSP04
IRIS yearly fee after 1st year for SP/SG/LP33U S/P 60-120kVA2 FIRSP12
IRIS yearly fee after 1st year for SP/SG/LP33U S/P 150-500kVA2 FIRSP50
Additional IRIS Fees
LincBox (CP4) Protocol Converter w/cables UPS11483
IRIS end user license per year incl. 1 password, email, fax or pager address LIREU01
IRIS additional Pager, FAX or email address, prices per message for each individual address AIR01
IRIS manual refresh UPS status (price per refresh/per UPS) RIR01
1Includes Lincbox
2Does not include Lincbox

Rev. 11/13 www.geindustrial.com BuyLog Catalog 20-45


Data subject to change
without notice
Uninterruptible Power Supplies Section 20
Digital Energy SG Series
All Models
Options, Spare Parts and Accessories

SG Series Connectivity, Software and Monitoring


Description RPA Product Number
Advanced SNMP/Web interface card, UTP/BNC UPS11701
Remote Status Panel (includes APS) UPS11785
Customer Interface Card (CIC) - six programmable relay contacts UPS1006691
External SNMP Interface Box (uses RS-232 connection to UPS) UPS1009223
IRIS Install Kit (includes modem and 1st year service)
IRSP04
Installation labor included if completed during unit commissioning.
IRIS Annual Fee (after 1st year) 400130.1
RS485/422 Converter 145994.0
1The SG Series UPS comes with one Customer Interface Card (CIC) pre-installed in the card cage.
The card cage has one open slot for optional cards.
This slot can hold either an additional Customer Interface Card OR an SNMP Interface Card, but not both.
2The Remote Status Panel uses the Customer Interface Card that is supplied with the system.
A second Customer Interface Card is required If relay contacts are required for other purposes (such as interface to an External Bypass Panel).
3Systems using the optional Customer Interface Card will need to use the External SNMP Interface Box, if SNMP connectivity is required.

GE Digital Energy SG Series Spare Parts Kits


kVA Rating Description Product Number
Parts kit, SG Series 10 kVA, fuses SK10SGA
10 kVA Parts kit, SG Series 10 kVA, basic SK10SGB
Parts kit, SG Series 10 kVA, comprehensive SK10SGC
Parts kit, SG Series 20 kVA, fuses SK20SGA
20 kVA Parts kit, SG Series 20 kVA, basic SK20SGB
Parts kit, SG Series 20 kVA, comprehensive SK20SGC
Parts kit, SG Series 30 kVA, fuses SK30SGA
30 kVA Parts kit, SG Series 30 kVA, basic SK30SGB
Parts kit, SG Series 30 kVA, comprehensive SK30SGC
Parts kit, SG Series 40 kVA, fuses SK40SGA
40 kVA Parts kit, SG Series 40 kVA, basic SK40SGB
Parts kit, SG Series 40 kVA, comprehensive SK40SGC
Parts kit, SG Series 50 kVA, fuses SK50SGA
50 kVA Parts kit, SG Series 50 kVA, basic SK50SGB
Parts kit, SG Series 50 kVA, comprehensive SK50SGC
Parts kit, SG Series 80 kVA, fuses SK80SGA
80 kVA Parts kit, SG Series 80 kVA, basic SK80SGB
Parts kit, SG Series 80 kVA, comprehensive SK80SGC
Parts kit, SG Series 100 kVA, fuses SK100SGA
100 kVA Parts kit, SG Series 100 kVA, basic SK100SGB
Parts kit, SG Series 100 kVA, comprehensive SK100SGC
Parts kit, SG Series 120 kVA, fuses SK120SGA
120 kVA Parts kit, SG Series 120 kVA, basic SK120SGB
Parts kit, SG Series 120 kVA, comprehensive SK120SGC
Parts kit, SG Series 150 kVA, fuses SK150SGA
150 kVA Parts kit, SG Series 150 kVA, basic SK150SGB
Parts kit, SG Series 150 kVA, comprehensive SK150SGC
Parts kit, SG Series 225 kVA, fuses SK225SGA
225 kVA Parts kit, SG Series 225 kVA, basic SK225SGB
Parts kit, SG Series 225 kVA, comprehensive SK225SGC
Parts kit, SG Series 300 kVA, fuses SK300SGA
300 kVA Parts kit, SG Series 300 kVA, basic SK300SGB
Parts kit, SG Series 300 kVA, comprehensive SK300SGC
Parts kit, SG Series 400 kVA, fuses SK400SGA
400 kVA Parts kit, SG Series 400 kVA, basic SK400SGB
Parts kit, SG Series 400 kVA, comprehensive SK400SGC
Parts kit, SG Series 500 kVA, fuses SK500SGA
500 kVA Parts kit, SG Series 500 kVA, basic SK500SGB
Parts kit, SG Series 500 kVA, comprehensive SK500SGC

SG Series Options and Accessories


Description RPA Product Number4
RPA Kit Installed in Factory/Start-up (10-40 kVA) for each UPS UPS15875
RPA Kit Installed in Factory/Start-up (50-80kVA) for each UPS UPS15876
RPA Kit Installed in Factory/Start-up (100-150kVA) for each UPS UPS15877
RPA Kit Installed in Factory/Start-up (225-300kVA) for each UPS UPS16241
RPA Kit Installed in Factory/Start-up (400-500 kVA) for each UPS16242
RPA Kit for Field Upgrade (10-500 kVA) UPS11626
4Parallel configured systems require one RPA kit per UPS module.

20-46 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Uninterruptible Power Supplies Section 20
Digital Energy SG Series
All Models
Services and Commissioning

SG Series UPS Commissioning and Extended Waranties1 (Single modules only)


System kVA Rating
Description Product Number 10 kVA 20 kVA 30 kVA 40 kVA 50 kVA 80 kVA 100 kVA 120 kVA 150 kVA 225 kVA 300 kVA 400 kVA 500 kVA
UPS Commissioning Service Level 1,
FSUSGxxxN
8AM to 5PM, Mon/Fri
UPS Commissioning Service Level 2,
FSUSGxxxP1
5PM to 8AM Mon/Fri, anytime Saturday
UPS Commissioning Service Level 3,
FSUSGxxxP2
Sunday/Holidays
UPS on-site Operator Training -
Provides instruction on proper use
TRNSxxxN
if users were not available at initial
commissioning. 8AM to 5PM, Mon/Fri
SG Series Extended Warranty Level 3 -
(sold during initial sale). Additional
12 months of UPS warranty. One PM
Uvisit covering UPS + 1 string of
VRLA batteries (at start of coverage), WARSGxxx
factoryrequired firmware updates
and remedial parts/labor for UPS only
(7x24, 12 hr response). Does not
include battery replacement.
SG Series Service Contract Level 3 -
(sold after initial sale). Additional
12 months of UPS service. One PM
visit covering UPS + 1 string of
VRLA batteries (at start of coverage), FSSGxxx
factory required firmware updates
and remedial parts/labor for UPS only
(7x24, 12 hr response). Does not
include battery replacement.
SG Series Basic Service. Includes
one PM visit covering UPS + 1
string of VRLA batteries, at
customer's connvenience, Sundays PMSGxxx
& Holidays excluded. Does not
included remedial parts/labor or
battery replacement.
Additional Semi-annual PM - adder
for performing a 2nd PM within
the 12 month period on the UPS
2PMSGxxx
+ 1 string of VRLA batteries.
Does not include remedial parts/labor
or battery replacement.
Additional Battery Strings - adder
for perfoming PM on each addional
string of VRLA batteries to be
BATSG
included in Warranty and Service
Contracts. Does not include
battery replacement.

SG Series UPS Commissioning (RPA Systems)


10 kVA - 120 kVA 150 kVA - 300 kVA 400 kVA - 500 kVA
Module Additional Module Additional Module Additional
Description Product Number Qty: 2 Modules (Each) Qty: 2 Modules (Each) Qty: 2 Modules (Each)
UPS Commissioning Service Level 1,
FSUSGRxxxNz
8AM to 5PM, Mon/Fri
UPS Commissioning Service Level 2,
5PM to 8AM Mon/Fri, FSUSGRxxxP1z
anytime Saturday
UPS Commissioning Service Level 3,
FSUSGRxxxP2z
Sunday/Holidays

"xxx" in the Product Number represents the UPS module kVA rating: '010' for 10kVA, '225' for 225kVA, etc.
"z" in the Product Number represents the total number of UPS modules in RPA systems.
UPS Commissioning by a GE-authorized Service Technician is required to initiate warranty coverage.
All equipment installation must be completed prior to commissioning (see Startup Checklist) and must be scheduled two weeks in advance.

Rev. 11/13 www.geindustrial.com BuyLog Catalog 20-47


Data subject to change
without notice
Uninterruptible Power Supplies Section 20
Digital Energy TLE Series UPS
225 to 1500 kW

The TLE Series UPS is one of the best performing three-phase UPS
systems providing critical power protection for a wide range of
applications. The TLE Series operates in VFI mode (Voltage
Frequency Independent) and has been developed to satisfy the
growing request of high efficiency through an innovative control
algorithm with 3-level inverter technology. This innovative product
provides best-in-class efficiency in double conversion mode as
well as eBoost operating mode. The TLE Series is developed
using GEs Design for Six Sigma methodology to help ensure that
the product fully meets customer requirements and expectations.
The TLE Series UPS provides industry-leading reliability, efficiency,
clean input performance and unity power factor at output.
Reliability can be further increased by paralleling more units
utilizing GEs unique RPA (Redundant Parallel Architecture)
technology. Through their complete life cycle, all GE UPS
systems are fully supported by service teams which provide
world-class, 24x7 preventive and corrective services, training
and application expertise.

Innovative Technology & Best-in-Class Efficiency


The TLE Series UPS brings the latest power conversion technology
to the marketplace, using a three-level inverter design and a
multimode architecture that makes real time decisions between
premium protection mode and premium eYciency mode. The TLE
Series UPS was developed using GEs Design for Six Sigma (DFSS) Electrical Environment Optimization
methodology to ensure that the product meets customer require- Unity (1.0) Output Power Factor
ments for reliability and quality. High (0.99) Input Power Factor
Less than 5% Input Current Harmonic Distortion
Technology at Its Best
Highly reliable and efficient tri-level conversion Physical Environment Optimization
Automatic or manual multi-mode operation Small footprint
Front access only design for maintenance
Best of Both Worlds Operating Efficiency Multi-Module cable saver design to allow +/- 25% differential
97% Efficiency in premium protection mode (double conversion) of cable lengths between UPS modules and I/O parallel buses
99% Efficiency in premium energy save mode (eBoost)

GE Multi-Mode Technology Concept

20-48 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Telecommunication Hardware Section 21

Introduction.................................................................................21-1
Fiber Closure Hardware ............................................................21-2
Cable Location Surge Protectors.............................................21-4

Introduction
GE has been manufacturing Telecommunication Hardware
products for over 20 years and has become a leader in providing
custom solutions in surge and filter protection and fiber closure
systems.

Note: Technical support is available.


Call (800) 637-1738

Rev. 11/13 www.geindustrial.com BuyLog Catalog 21-1


Data subject to change
without notice
Telecommunication Hardware Section 21
Fiber Closure Hardware
Splice Accessories and Enclosures
100A - Protective Fusion Splice Sleeves
Available in 1 5/8", 2 3/8" or 3" lengths
Provide both mechanical and environmental protection
for fibers that have been stripped, cleaved, and fused into a
continuous length
Composed of an outer heat-shrink tube, an inner hot melt
adhesive tube, and stainless steel strength member
The inner hot-melt adhesive tube hermetically seals around the Splice Sleeve
splice preventing ingress of moisture into the sleeve
May be used with both single and multi-mode fibers and are
compatible with other leading brand trays
Excellent reinforcement of Fusion Spliced Fiber
No end crimping or micro-bending of fibers
May be installed using a standard heat shrink oven or with a
heat gun
200, 201, 205 and 206 Series Splice Trays
Holds any GE Fusion Splice Sleeves or other industry-standard
fusion splices:
Tray sizes available: 4" W x 12" L, 4.5" W x 12" L or 4.5" W x 6.5" L
Accommodates 1-36 m splices
Some trays available with a fabric liner. The fabric liner provides
a cushion to keep glass fibers from vibrating in the trays.
GE customizes trays to OEM requirements and manufactures trays
in a variety of materials including aluminum, plastic and Lexan
Splice Tray
Organizer Boxes
FEATURES COMMON TO ALL
Entrance can be drilled for buffered fibers and various types of
outdoor plant cable.
Split compression seal available.
Utilized in butt configurations.
Used to protect fiber & splices when using encapsulants.
227-02
Accommodates up to six 200 or 205 Series Splice Trays for 1-72
mechanical or 1-144 fusion fiber splices
E/W two slots for fiber cable entrance and four holes for ground
wire entrance
Designed for use with GEs 720 Closure System
Dimensions: 18" L x 4.75" W x 3.5" H
(457 mm L x 120 mm W x 89 mm H)
227-04
Accommodates up to twelve 200 or 205 Series Splice Trays for
1-144 mechanical or 1-288 fusion fiber splices
E/W two slots for fiber cable entrance and four holes for ground
wire entrance
Designed for use with GEs 730 Closure System
Dimensions: 18" L x 4.75" W x 5" H (457 mm L x 120 mm W x
127 mm H)
227-05
Accommodates up to six splice trays for 1-72 mechanical or
1-144 fusion fiber splices
E/W with slot for cable and ground wire entrance
Specially designed organizer box equipped with a file type
splice tray holder and side mounting lid
Provides individual tray slots which create easy accessibility
to a particular splice tray without disturbing other trays in
the organizer
Designed for use with GEs 720 Closure System
Dimensions: 18" L x 4.75" W x 3.5" H
(457 mm L x 120 mm W x 89 mm H)

21-2 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Telecommunication Hardware Section 21
Fiber Closure Hardware
Splice Accessories and Enclosures

Specifications
710 - 4" (102mm) x 21" (533mm)
711 - 4" (102mm) x 25" (635mm)
Hold 2 splice trays
Accommodate 1-30 spliced fibers
Accept cables up to 7/8" in diameter
720 - 6" (152mm) x 28" (711mm)
725 - 6" (152mm) x 32" (813mm)
Hold 6 or 8 splice trays
Accommodate 1-216 spliced fibers
Accept cables up to 1" in diameter
730/732- 8" (203mm) x 32" (813mm)
Hold up to 12 splice trays
Accommodate 1-432 spliced fibers
Accept cables up to 1 1/4" in diameter
Material
Cylindrical Housing - Rigid, non-corrosive,
high impact extruded plastic.
Inner Parts
Non corrosive metallic materials.
Each splice closure comes equipped with
cable pull brackets.
710/711 720-08 720-28 730/732 Cylindrical
Shipping Weight:
Housing
710 8lbs. (3.6kg)
720 17lbs. (7.7kg)
732 34lbs. (15.4kg)
OPGW Closures Closures equipped with Surge Protectors - Patent#: 5,652,820
The GE Fiber 705-XXX OPGW frame is designed for splicing and By integrating the Fiber Cable Protector with the Fiber Closure
terminating OPGW fiber cables. The frame provides an interface System, the installation of a Fiber Cable Locating System is
between the standard GE fiber optic splice closure and the OPGW simplified. The cable protector is preinstalled and tested with the
cable. Aluminum clamping plates mounted to the frame provide fiber closure, splice trays, ground lugs and ground wires. Each
the pull-out strength required for the heavy cables, isolating the system is also equipped with mounting brackets for both man-
stress away from the closure. The splice closures mount to the hole and aerial installations. This system saves many installation
frame with a standard pole mount bracket, allowing easy assem- hours and minimizes installation errors in the field.
bly and quick re-entry to the closure. The unique feature of this product is its capability to protect
The GE OPGW frame accommodates the 4" diameter 710-03, the multiple fiber optic cables while allowing the cables to be
6" diameter 720-08, and the 8" diameter 730-05 fiber optic splice remotely located from one source.
closures. This provides the installer the option to purchase a small- Cable locating and surge protection integrated into
er, more economical closure when installing low fiber count OPGW closure system.
cables. The large 730-05 closure can be used when installing high Multiple cable capability. (backbone plus 4 branch)
fiber count OPGW cables. Each of the above closures will accom- Initial cost savings.
modate splicing OPGW cables to OPGW cables or OPGW cables to Cut installation time.
dielectric cables. The larger closures (720-08 and 730-05) will each Eliminate extra hand hold.
accept up to four OPGW cables and two dielectric cables at a Convenient access.
time. Cable clamps are available to accommodate OPGW cables Available with 6" or 8" closures.
with outside diameters ranging from .465" to .646".
For special applications, the GE OPGW frame can be mounted
inside the 705002008 galvanized steel canister. This canister pro-
vides a bullet resistant shell to protect the fiber optic splice closure.

OGPW Closure Closure with Surge Protector

Rev. 11/13 www.geindustrial.com BuyLog Catalog 21-3


Data subject to change
without notice
Telecommunication Hardware Section 21
Cable Location Surge Protectors

GE 44X Family of Products


GE 440 GE 445
The GE 440 Cable Locating Switching Device is a manually The GE 445 Cable Locating Protection Device is a remote switching
operated switch, normally mounted on a pedestal, which device controlled by a link monitoring system/Long Line
provides two basic functions. When the switch is closed, the Transmitter System (LMS/LLTS). In addition, the GE 445 unit
GE 440 provides cable sheath continuity. When the switch is is built with a high energy surge protector. The surge protector
open, it provides isolation between the East and West cable provides a low impedance path for high energy signals (lightning,
sheath so that portable cable location transmitters may be power cross, etc.) and a high impedance path for low energy
connected. signals cable locating tones). A heavy duty relay is installed in
GE 442 this unit, allowing the cable sheath to remain grounded while
The GE 442 Cable Locating Protection Device is an intelligent de-energized. When a 48 volt DC signal is applied from the
surge protection switching system installed between the cable LMS/LLTS, earth ground is removed from the cable and connected
sheath and earth ground. Its primary function is to increase the to the LMS/LLTS to the cable sheath. Available in 1, 2, 4 and 16
cable locating tone range and efficiency and protect buried cable way switches.*
from high energy surges. The GE 442 is normally mounted in a GE 446
pedestal to allow easy field access.* The GE 446 Dual Cable Locating Protection Device is a dual
GE 444 protection unit designed to protect against high energy surges
The GE 444 Cable Locating Protection Device is an indoor/outdoor while providing isolation between the East and West cable
intelligent switching system installed between the cable sheath sheath. By isolating the East and West cable sheath, allowing indi-
and earth ground. Its primary function is to increase the cable vidual cable section testing in the field.*
locating tone range and efficiency and protect buried cable GE 447
from high energy surges. The GE 444 may be installed either The GE 447 Band Reject Filtering System is a two stage protection
underground or above ground because of its weather-proof system installed between the cable sheath and earth ground.
enclosure. The GE 444 may also be bracket-mounted on the Fiber The GE 447 increases cable locating or cable monitoring range
Closures. This method reduces installation time by several hours.* while protecting buried cable from high energy surges and 60 Hz
induced voltage. The first stage uses GEs standard cable protec-
tion technology and the second stage utilizes a 60 Hz band reject
filter. The GE 447 increases cable locating efficiency and allows
more than 40 miles of cable to be located with one transmitter.*

*U.S. Patent No. 5,721,662

21-4 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Telecommunication Hardware Section 21
Cable Location Surge Protectors

City Ring
444 (end)

LMS
444 (intermediate)
LMS & 445X
(switch)
445X 444

(farthest point
from switch box)

444 444

444

444 444

444 Thru splice w/GRD

444

Point to Point
GE 442

LMS 445X

444 444 444

Thru splice w/GRD 444

LMS & 445X 446

GE 444

GE 445X

444

444
444

Note: Technical support is available.


Call (800) 637-1738 GE 446

Rev. 11/13 www.geindustrial.com BuyLog Catalog 21-5


Data subject to change
without notice
Telecommunication Hardware Section 21

NOTES:

21-6 BuyLog Catalog www.geindustrial.com Rev. 11/13


Data subject to change
without notice
Relays and Meters Section 22

With our global brands of Multilin, MDS, Lentronics and ITI, GE For more information on these products, please visit our website
Digital Energy designs, manufactures, distributes and supports a at www.gedigitalenergy.com or contact your local sales
full range of protection, control, metering, telecommunications representative. GE Digital Energy provides worldwide customer
and power sensing equipment, software and services for indus- support 24/7 for its products and systems through its Customer
trial, utility and transportation customers. Support Centers.
The Multilin line of protection and control products are based on Contact us directly:
industry leading technologies essential for the reliable operation North America / Worldwide Europe / Middle East / Africa
of mission-critical applications including generation, transmission, 215 Anderson Ave. Avenida Pinoa 10-48170
distribution, metering, motors, and communications. Multilin pro- Markham, Ontario Zamudio (Vizcaya), Spain
tection relays and systems are complemented with a complete Canada L6E 1B3 Tel.: +34 94 485 88 00
line of substation hardened multiplexers, Ethernet switch network Toll Free (NA Only): Fax: +34 94 485 88 45
devices, and wireless radios for utility teleprotection, industrial, 1-800-547-8629 E-mail: gemultilin.euro@ge.com
transit, railways, and highway traffic management systems. Every Tel.: 905-294-6222
aspect of device configuration and monitoring is made simple Fax: 905-201-2098
through the powerful EnerVista suite of software tools. All relays E-mail: gemultilin@ge.com
are programmed and managed through EnerVista Software.
The GE Digital Energy ITI brand of power sensing products Asia
include a full line of current, voltage and potential transformers, Floor 22-24, No 900 Yishan Rd.
switches, indicating lights and other protection relay accessories. Scientific Building C
Complimenting our products, we also offer a complete range of Shanghai, China 200233
consulting services, customized panel solutions and fully inte- Tel.: +86 21 2401 3208
grated energy management systems for effective energy savings. Fax: +86 21 5423 5080

Protection & Control B90 Multiple Section Busbar Protection ....................................22-66


Protection & Control Product Families....................................22-3 B30 Busbar Protection .......................................................................22-68
UR Family Protection System ............................................................22-4 MIB High Impedance Busbar Protection ...................................22-70
SR Enhanced Drawout Protection System ...............................22-13 HID High Impedance Auxiliary Protection Module ..............22-71
650 Mid-range Protection System................................................22-14 Distribution Feeder Protection...............................................22-72
SR 3-Series Protection ........................................................................22-15 Distribution Feeder Protection Selector Guide...........................22-74
MII Modular Protection System......................................................22-17 F60 Feeder Protection with Hi-Z Detection..............................22-76
Generator Protection ...............................................................22-22 F35 Multiple Feeder Protection ......................................................22-78
Generator Protection Selector Guide ..........................................22-23 750/760 Comprehensive, Draw Out Feeder Protection .....22-80
G60 Medium to Large Generator Protection ...........................22-24 F650 Feeder/Bay Protection............................................................22-82
G30 Combined Generator and Transformer Protection ....22-26 350 50/51 Feeder Protection ..........................................................22-84
489 Small to Medium Generator Protection ............................22-28 A60 Arc Flash Detection ....................................................................22-86
G650 Distributed Generator Protection .....................................22-30 735/737 Three-Phase and Ground Feeder Protection........22-87
W650 Wind Turbine Generator Protection...............................22-32 MIF II Economical Feeder Protection with Recloser .............22-88
MIG II Small Generator Protection ................................................22-34 FM2 Low Voltage Feeder Protection............................................22-89
MIW II Directional Power/Loss of Field Protection ................22-35 Motor Protection.......................................................................22-90
Transformer Protection ...........................................................22-36 Motor Protection Selector Guide ...................................................22-92
Transformer Protection Selector Guide .....................................22-37 M60 Medium to Large Motor Protection....................................22-94
T60 Medium to Large Transformer Protection .......................22-38 469 Medium to Large Motor Protection.....................................22-96
T35 6 Winding Transformer Protection......................................22-40 369 Small to Medium Motor Protection .....................................22-97
745 Medium to Large Transformer Protection.......................22-42 369 Draw-out Motor Protection ....................................................22-99
345 Small to Medium Transformer Protection .......................22-44 339 Small to Medium Motor Protection ..................................22-101
Transmission Line Protection.................................................22-46 269Plus Small to Medium Motor Protection .............................22-103
Transmission Protection Selector Guide....................................22-48 239 Small to Medium Motor Protection ..................................22-104
L90 Line Current Differential Protection ....................................22-50 MM300 Low Voltage Motor Management...........................22-105
L60 Phase Comparison Protection...............................................22-52 MM2 Low Voltage Motor Management...................................22-107
L30 Line Current Differential System...........................................22-54 SPM Synchronous Motor Protection .........................................22-109
D90Plus Sub-Cycle Distance Protection........................................22-56
D60 Distance Protection ...................................................................22-58
D30 Backup Distance Protection ..................................................22-60
Bus Protection ...........................................................................22-62
Bus Protection Selector Guide........................................................22-63
B95Plus Busbar Protection ..................................................................22-64 (Continued on page 22-2)

Rev. 11/13 www.gedigitalenergy.com BuyLog Catalog 22-1


Data subject to change
without notice
Relays and Meters Section 22

Specialized Protection, Control and Recording.................22-110 Media & Protocol Converters ...............................................22-187
C60 Breaker Monitoring and Control........................................22-111 MultiNet RS485 to Ethernet ........................................................22-188
C30 I/O Logic Controller..................................................................22-113 Media & Protocol Converters........................................................22-189
N60 Network Stability and Synchrophasor Measurement .....22-115 Power Sensing
C70 Capacitor Bank Protection...................................................22-117 Instrument Transformers .....................................................22-190
C90Plus Automation Control System...........................................22-119 Current Transformers ......................................................................22-190
HardFiber 61850 Process Bus......................................................22-121 Low Voltage Potential Transformers ........................................22-193
MIV II Voltage/Frequency Protection........................................22-123 Bushing Current Transformers....................................................22-194
MIN II Ground Protection................................................................22-124 Medium Voltage Instrument Transformers ...........................22-194
RRTD Remote RTD Metering Module for the 369 ................22-125 Control Power Transformers ........................................................22-195
DDFR Distributed Digital Fault Recorder.................................22-126 Current Transducers.........................................................................22-195
Single Function Protection Relays.......................................22-128 IEC Rated Instrument Transformers .........................................22-196
Single Function Auxiliary Relays..........................................22-138 Accessories ..............................................................................22-197
Substation Gateways and RTU.............................................22-140 Switches
D400 Advanced Substation Gateway ......................................22-140 SB-1, SB-9, Series 95.........................................................................22-197
D20MX Substation Controller.......................................................22-142 SB-10, SBM, FT, RT Test Switch ....................................................22-198
D.20 RIO Distributed I/O Controller............................................22-144 Test Equipment
D25 Substation Controller .............................................................22-145 515, PK2, XCA, XLA.............................................................................22-199
Metering Terminal Blocks
Digital Metering ......................................................................22-147 116B407, EB-25, EB-26, EB-27, IKU, EB-1, EB-2, EB-4.......22-199
Digital Metering Family Selection Guide .................................22-148 Indicator Lights
PQM II Power Quality Meter ..........................................................22-149 ET-16, ET-16 LED, ET-17..................................................................22-199
EPM 9900 Advanced Power Quality Meter ............................22-150 Test Equipment
EPM 9800 Socket Mounted Power Quality Meter ...............22-152 RTT Desktop Test Set ........................................................................22-200
EPM 9000 Advanced Power Quality Meter ............................22-154 Software
EPM 7000 Revenue Class PQ Meter ..........................................22-156 EnerVista Suite......................................................................22-202
EPM 6010 Building Automation Meter .....................................22-158 Launchpad Device Setup & Document Management .....22-203
EPM 6000 Revenue Class Power Meter ...................................22-159 Viewpoint Engineer Control Logic Creator &
EPM 2200 Power Meter ...................................................................22-160 Commissioning Toolset ...................................................................22-206
EPM 4500 Multi-tenant Sub-Metering System.....................22-161 Viewpoint Maintenance Device Health &
EPM 1500 Single-point Sub-Metering System .....................22-164 Security Reporting.............................................................................22-210
EPM 7100 Energy Submeter w/WIFI and Logging .............22-166 Viewpoint Monitoring & Data Recording ................................22-214
EPM 6100 Energy Submeter w/WIFI .........................................22-167 Integrator OPC/DDE Communications Server .....................22-224
GE Meter in a Box (MIB) ...................................................................22-168 Value Added Services
Communications Value Added Services.............................................................22-227
Multiplexers .............................................................................22-170 Energy Management Systems.....................................................22-227
Multiplexer Family Overview ........................................................22-171 Advanced Training Services..........................................................22-229
JMUX SONET Multiplexer................................................................22-174 Consulting Services...........................................................................22-231
JMUX T1 Multiplexer .........................................................................22-174 Packaged Solutions ..........................................................................22-233
TN1U SDH Multiplexer .....................................................................22-175 Product Upgrades And Replacements
TN1Ue SDH Enhanced Multiplexer ............................................22-175 Product Upgrades and Replacements................................22-234
VistaNET Network Management Software .........................22-176
MDS Wireless Solutions...................................................................22-178
Ethernet Switches...................................................................22-181
Multilink Family Overview ..............................................................22-181
ML3000 19 Rack-mounted Managed Switch......................22-182
ML2400 19 Rack-mounted Managed Switch......................22-184
ML1600 9 Panel-mounted Managed Switch.......................22-185
ML600 Unmanaged Compact Switch ......................................22-186

22-2 BuyLog Catalog www.gedigitalenergy.com Rev. 11/13


Data subject to change
without notice
Relays and Meters Section 22
Protection and Control
Product Families

UR Universal Relay Family page 22-4


Superior protection, control and communication for utility and industrial
applications.
The Universal Relay (UR) is a family of leading edge protection and control products built
on a common modular platform. All UR products feature high performance protection,
expandable I/O options, integrated monitoring and metering, high speed communica-
tions, and extensive programming and configuration capabilities.

SR Relay Family page 22-13


Competitive industrial power management systems for motors, generators,
transformers and feeders.
The SR Family of protection relays represents a multi-functional line of products, with
draw out capabilities. By providing protection, control, monitoring, metering, and both
local and remote user interfaces in one assembly, the SR relays effectively eliminate the
need for expensive discrete components.

650 Relay Family page 22-14


Advanced protection, control and monitoring system.
The 650 family of relays incorporate a new generation of products that provides compre-
hensive protection, control monitoring and metering in a compact and cost effective
package. The architecture is a complete solution for different applications, that complies
with the most relevant international standards, including IEC61850 protocol.

SR 3 Family page 22-15


Protective relay systems for feeders, motors and transformers
The SR 3 Series protection relays family is a highly functional and economical protection
system. They provide a system for protection, control, monitoring and metering, and both
local and remote user interfaces in one assembly.

MII Modular Microprocessor Family page 22-17


An economical choice for digital relaying applications.
The MII Family offers a competitive solution that combines advanced protection, monitor-
ing, widely accepted communications standards, and flexible configuration tools for a
range of protection applications.

Rev. 11/13 www.gedigitalenergy.com BuyLog Catalog 22-3


Data subject to change
without notice
Relays and Meters Section 22
Protection & Control
UR & URPlus
Proven, State-of-the-Art Protection & Control Systems
Key Benefits
Modular construction: common hardware, reduced stock of
spare parts, plug & play modules for maintenance cost savings
and simplification
Proven flexibility and customization capabilities make UR/
URPlus devices suitable to retrofit almost any kind of legacy
P&C scheme
Large HMI and annunciator panels provide local monitoring and
control capabilities, and backup the substation HMI
Phasor Measurement Unit (synchrophasor) according to IIEEE
C37.118 (2011) and IEC 61850-90-5 directly streamed from your
protective device
Three ethernet ports enable purpose specific LAN support that
eliminates latency effect of heavy traffic protocols on mission
critical communication services
Embedded IEEE 1588 time synchronization protocol support
eliminates dedicated IRIG-B wiring requirements for P&C devices Features
Complete IEC 61850 Process Bus solution provides resource
Protection and Control
optimization and minimizes total P&C life cycle costs
Fast and segregated line current differential and distance
Increase network availability by reducing failover time to zero
protection functionality in a single device
through IEC 62439-3 PRP support
Phase segregated line current differential with adaptive restraint
CyberSentry provides high-end cyber security aligned to
and ground differential, stub bus protection
industry standards and services (NERC CIP, based, AAA, Radius,
Phase distance (five zones) with independent settings
RBAC, Syslog)
for compensation
Enhanced CT/VT module diagnostics verify analog signal
Single-pole tripping, breaker-and-half wit independent current
integrity using an advanced algorithm, ensuring reliability
source support
Reduces system event analysis effort with the support of
Complete generator protection with 100% stator ground
embedded high-end and extended recording functionality
fault detection with sub-harmonic injection and field
Applications ground protection
Protection, control, monitoring and supervision of power assets
across generation, transmission, distribution, substation and
industrial systems
Utility substation and industrial plant automation
Digital fault recording and Sequence of Event (SOE) recording
Predictive maintenance through data analysis and trending
Synchrophasor based monitoring and control systems with
specialized PMU devices that support multiple feeders
Complex protection & control and wide area monitoring
solutions with complete diagnostic and automation
capabilities (URPlus)

22-4 BuyLog Catalog www.gedigitalenergy.com Rev. 11/13


Data subject to change
without notice
Relays and Meters Section 22
Protection & Control
UR & URPlus
Proven, State-of-the-Art Protection & Control Systems
Features (Continued) EnerVista Software
Graphical Logic Designer and Logic Monitor to simplify
Communications
configuration and testing proceduresvia EnerVista UR Engineer
Networking interfaces: 10 or 100MB copper or fiber optic
Service and update notification toolset ensures device docu-
Ethernet, RS485, RS232, RS422, G.703, C37.94, up to three
ments and software are up-to-date via EnerVista Launchpad
independent ethernet ports
EnerVista Integrator providing easy integration of data in the
Multiple protocols: IEC 61850, DNP 3.0 Level 2, Modbus RTU,
UR Family into new or existing monitoring and control systems
Modbus TCP/IP, IEC 60870-5-104, Ethernet Global data, IEEE 1588
and PRP
Direct I/O: secure, high-speed exchange of data between URs for
direct transfer trip and I/O extension applications
IEC 61850 Process Bus Interface
Robust communications with up to 8 HardFiber Bricks
Redundant architecture for dependability and security
Monitoring and Metering
Synchrophasors in select products with IEEE C37.118 (2011) and
IEC 61850-90-5 support
Advanced recording capabilities deliver a 1024 event recorder,
configurable and extended waveform capture and data logger
Fault locator and user-programmable fault reports
Breaker condition monitoring including breaker arcing current
(I2t), breaker re-strike and breaker flashover
Metering: current, voltage, power, power factor, frequency,
voltage & current harmonics, energy, demand, phasors, etc.

Rev. 11/13 www.gedigitalenergy.com BuyLog Catalog 22-5


Data subject to change
without notice
Relays and Meters Section 22
Protection & Control
UR & URPlus
Selector Guide

Features ANSI B30 B90 B95Plus C30 C60 C70 C90Plus D30
Protection
1. Disturbance Detector
2. Mho Distance, Phase (No. of Zones) 21P 5
3. Mho Distance, Ground or Neutral Phase (No. of Zones) 21G/N 3
4. Quadrilateral Distance, Phase (No. of Zones) 21P 3
5. Quadrilateral Distance, Ground or Neutral (No. of Zones) 21G/N 3
6. Permissive Pilot Logic
7. Sub-Cycle Distance
8. Overexcitation Protection (V/Hz) 24
9. Synchronism Check or Synchronizing 25
10. Undervoltage, Phase 27P
11. Undervoltage, Auxiliary 27X
12. Stator Ground (3rd Harmonic) 27TN
13. Sensitive Directional Power 32S
14. Loss of Excitation Based on Reactive Power 40Q
15. Loss of Excitation Based on Impedance Element 40
16. Current Unbalance 46
17. Broken Conductor Detection 46BC
18. IOC, Negative Sequence 46/50
19. TOC, Negative Sequence 46/51
20. Current Directional, Negative Sequence 46/67
21. Reverse Phase Sequence Voltage 47
22. Thermal Model 49
23. Inadvertent/Accidental Energization 50/27
24. End of Fault Protection
25. Motor Mechanical Jam
26. Motor Start Supervision
27. Motor Acceleration Time
28. User Programmable Curves
29. Breaker Failure 50BF Logic
30. IOC, Phase 50P
31. IOC, Ground 50G
32. IOC, Neutral 50N
33. IOC, Sensitive Ground 50SG
34. High Impedance Fault Detection
35. TOC, Phase 51P
36. TOC, Ground 51G
37. TOC, Neutral 51N
38. TOC, Sensitive Ground 51SG
39. TOC, Voltage Restrained 51V
40. Overvoltage, Phase 59P
41. Overvoltage, Auxiliary 59A
42. Overvoltage, Neutral 59N
43. Negative Sequence Overvoltage 59-2
44. 100% Stator Ground Protection 64TN
45. Current Directional, Phase 67P
46. Current Directional, Neutral 67N
47. Current Directional, Negative Sequence 46/67
48. Power Swing Blocking 68
49. Out-of-Step Tripping 78
50. AC Reclosing (No. of Shots) 79 4 4
51. Switch on to Fault (Line Pickup) SOTF
52. Voltage Transformer Fuse Failure VTFF
53. Current Transformer Supervision 50/74
54. Load Encroachment Logic
55. Underfrequency 81U
56. Overfrequency 810
57. Anti-Islanding Protection/Frequency Rate of Change 81R
58. Lockout Functionality 86
59. Bus Differential 87B
60. Line Current Differential 87L
61. Ground Differential 87G
62. Stator Differential 87S
63. Group Differential 87T
64. Line Phase Comparison 87PC
65. Voltage Differential
66. Capacitor Bank Overvoltage
67. Neutral Voltage Unbalance
68. Automatic Voltage Regulation
69. Time of Day Control
70. Instantaneous Differential 50/87
71. Split Phase Protection
72. Line Current Differential Trip Logic
73. CT Failure

22-6 BuyLog Catalog www.gedigitalenergy.com Rev. 11/13


Data subject to change
without notice
Relays and Meters Section 22
Protection & Control
UR & URPlus
Selector Guide

D60 D90Plus F35 F60 G30 G60 L30 L60 L90 M60 N60 T35 T60


5 5 3 3 5 5
5 5 3 3 3
5 5 3 3 3
5 5 3 3 3





















Logic Logic Logic Logic Logic




















4 4 4 4 4 4







Rev. 11/13 www.gedigitalenergy.com BuyLog Catalog 22-7


Data subject to change
without notice
Relays and Meters Section 22
Protection & Control
UR & URPlus
UR Technical Specifications
PROTECTION PROTECTION PROTECTION
100% STATOR GROUND BREAKER FAILURE Timing accuracy: 3% or 4 ms, whichever is greater
Operating quantity: V_neutral_3rd/(V_neutral_3rd + Current supervision:
Mode: 1-pole, 3-pole Level: neutral current (3I_0)
V_zero_3rd) Current supervision: phase, neutral current Pickup: 0.050 to 30.000 pu in steps of 0.001
Pickup level: 0.000 to 0.250 pu in steps of 0.001 Current supv. pickup: 0.001 to 30.000 pu in steps of 0.001 Dropout: 97 to 98%
Dropout level: 97 to 98% of pickup Current supv. dropout: 97 to 98% of pickup Memory duration: 5 to 25 cycles in steps of 1
Level accuracy: 2% of reading from 1 to 120 V Current supv. accuracy: Voltage supervision pickup 0 to 5.000 pu in steps of 0.001
Pickup delay: 0 to 600.00 s in steps of 0.01 0.1 to 2.0 CT rating: 0.75% of reading or 2% of rated (series compensation
3rd harmonic 0.0010 to 0.1000 pu in steps of 0.0001 (whichever is greater) applications):
supervision level: above 2 CT rating: 2.5% of reading Operation time: 1 to 1.5 cycles (typical)
Time accuracy: 3% or 20 ms, whichever is greater BREAKER FLASHOVER Reset time: 1 power cycle (typical)
Operate time: < 30 ms at 1.10 Pickup at 60 Hz
Operating quantity: Phase current, voltage and GROUND DISTANCE OPERATING TIME CURVES
ACCELERATION TIME voltage difference The operating times are response times of a microprocessor part
Acceleration current: 1.00 to 10.00 FLA in steps of 0.01 Pickup level voltage: 0 to 1.500 pu in steps of 0.001 of the relay. See output contacts specifications for estimation of
Acceleration time: 0.00 to 180.00 s in steps of 0.01 Dropout level voltage: 97 to 98% of pickup the total response time for a particular application. The operating
Operating mode: Definite Time, Adaptive Pickup level current: 0 to 1.500 pu in steps of 0.001 times are average times including variables such as fault incep-
Dropout level current: 97 to 98% of pickup
ACCIDENTAL ENERGIZATION tion angle or type of a voltage source (magnetic VTs and CVTs).
Level accuracy: 0.5% or 0.1% of rated,
Operating condition: Overcurrent whichever is greater
Arming condition: Undervoltage and/or Machine Offline Pickup delay: 0 to 65.535 s in steps of 0.001
Overcurrent: Time accuracy: 3% or 42 ms, whichever is greater
Pickup level: 0.000 to 3.000 pu in steps of 0.001 Operate time: <42 ms at 1.10 pickup at 60 Hz
Dropout level: 97 to 98% of pickup
Level accuracy: 0.5% of reading from 0.1 to BUS DIFFERENTIAL (87B)
2.0 CT rating Pickup level: 0.050 to 6.000 pu in steps of 0.001
Undervoltage: Low slope: 15 to 100% in steps of 1
Pickup level: 0.000 to 3.000 pu in steps of 0.001 High slope: 50 to 100% in steps of 1
Dropout level: 102 to 103% of pickup Low breakpoint: 1.00 to 30.00 pu in steps of 0.01
Level accuracy: 0.5% of reading 10 to 208 V High breakpoint: 1.00 to 30.00 pu in steps of 0.01
Operate Time: < 30 ms at 1.10 Pickup at 60 Hz High set level: 0.10 to 99.99 pu in steps of 0.01
Dropout level: 97 to 98% of Pickup
AUTORECLOSURE C60/D60/L90/L60 Level accuracy:
Two breakers applications 0.1 to 2.0 CT rating: 0.5% of reading or 1% of rated
Single- and three-pole tripping schemes (whichever is greater)
Up to 4 reclose attempts before lockout >2.0 CT rating 1.5% of reading
Selectable reclosing mode and breaker sequence Operating time: one power system cycle (typical)
AUTORECLOSURE F60/F35/D30 CT TROUBLE
Single breaker applications, 3-pole tripping schemes Responding to: Differential current
Up to 4 reclose attempts before lockout Pickup level: 0.020 to 2.000 pu in steps of 0.001 LINE CURRENT DIFFERENTIAL (87L)
Independent dead time setting before each shot Pickup delay: 1.0 to 60.0 sec. in steps of 0.1 Application: 2 or 3 terminal line, series compen-
Possibility of changing protection settings after each shot Time Accuracy: 3% or 40ms, whichever is greater sated line, tapped line, with charging
with FlexLogic. Availability: 1 per zone of protection (B90) current compensation
AMP UNBALANCE Pickup current level: 0.20 to 4.00 pu in steps of 0.01
GENERATOR UNBALANCE CT Tap 0.20 to 5.00 in steps of 0.01
Avg and Full Load amps: RMS Gen. nominal current: 0.000 to 1.250 pu in steps of 0.001 (CT mismatch factor):
I_1 and 1_2 amps: Phasor Stages: 2 (I2t with linear reset and definite time) Slope # 1: 1 to 50%
Pickup level: 0.0 to 100.0% in steps of 0.1 Pickup level: 0.00 to 100.00% in steps of 0.01 Slope # 2: 1 to 70%
Dropout level: 97 to 98% of pickup Dropout level: 97 to 98% of pickup Breakpoint between slopes: 0.0 to 20.0 pu in steps of 0.1
Level accuracy: 0.1 Level accuracy: DTT: Direct Transfer Trip (1 and 3 pole)
Pickup delay: 0.00 to 600.00 s in steps of 0.01 0.1 to 2 x CT rating: 0.5% of reading or 1% of rated remote L90
Reset delay: 0.00 to 600.00 s in steps of 0.01 (whichever is greater) Operating Time: 1.0 to 1.5 power cycles duration
Operate time: < 20 ms at 1.10 pickup at 60 Hz > 2.0 x CT rating: 1.5% of reading Asymmetrical channel asymmetry up to 10ms
Timing accuracy: 3% or 20 ms, whichever is greater Time dial (K-value): 0.00 to 100.00 in steps of 0.01 delay compensation
AUXILIARY OVERVOLTAGE Pickup delay: 0.0 to 1000.0 s in steps of 0.1 using GPS:
Reset delay: 0.0 to 1000.0 s in steps of 0.1
Pickup level: 0.000 to 3.000 pu in steps of 0.001 Time accuracy: 3% or 20 ms, whichever is greater LINE CURRENT DIFFERENTIAL TRIP LOGIC
Dropout level: 97 to 98% of Pickup Operate time: < 50 ms at 60 Hz 87L trip: Adds security for trip decision; creates 1
Level accuracy: 0.5% of reading from 10 to 208 V and 3 pole trip logic
Pickup delay: 0 to 600.00 s in steps of 0.01 GROUND DISTANCE DTT: Engaged Direct Transfer Trip
Reset delay: 0 to 600.00 s in steps of 0.01 Characteristic: Mho (memory polarized or offset) or Quad (1 and 3 pole) from remote L90
Timing accuracy: 3% of operate time or 4 ms (memory polarized or non-directional), DD: Sensitive Disturbance Detector
(whichever is greater) selectable individually per zone to detect fault occurrence
Operate time: < 30 ms at 1.10 pickup at 60 Hz Reactance polarization: negative-sequence or Stub bus protection: Security for ring bus and
AUXILIARY UNDERVOLTAGE zero-sequence current 1 breaker configurations
Non-homogeneity angle: -40 to 40 in steps of 1 Open pole detector: Security for sequential and
Pickup level: 0.000 to 3.000 pu in steps of 0.001 Number of zones: 5 evolving faults
Dropout level: 102 to 103% of pickup Directionality: Forward, Reverse, or Non-Directional
Level accuracy: 0.5% of reading from 10 to 208 V per zone LINE PICKUP
Curve shapes: GE IAV Inverse, Definite Time Reach (secondary W): 0.02 to 250.00 in steps of 0.01 Phase IOC: 0.000 to 30.000 pu
Curve multiplier: Time Dial = 0 to 600.00 in steps of 0.01 Reach accuracy: 5% including the effect of CVT Undervoltage pickup: 0.000 to 3.000 pu
Timing accuracy: 3% of operate time or 4 ms transients up to an SIR of 30 Overvoltage delay: 0.000 to 65.535 s
(whichever is greater) Distance characteristic 30 to 90 in steps of 1 LOAD ENCROACHMENT
BREAKER ARCING CURRENT angle:
Distance comparator 30 to 90 in steps of 1 Responds to: Positive-sequence quantities
Principle: Accumulates breaker duty (I2t) and Minimum voltage: 0.000 to 3.000 pu in steps of 0.001
limit angle:
measures fault duration Reach (sec. W): 0.02 to 250.00 in steps of 0.01
Directional supervision
Initiation: Programmable per phase from any Impedance accuracy: 5%
Characteristic angle: 30 to 90 in steps of 1
FlexLogic operand Angle: 5 to 50 in steps of 1
Limit angle: 30 to 90 in steps of 1
Compensation for 0 to 65.535 s in steps of 0.001 Angle accuracy: 2
Zero-sequence compensation
auxiliary relays: Pickup delay: 0 to 65.535 s in steps of 0.001
Z0/Z1 magnitude: 0.00 to 10.00 in steps of 0.01
Alarm threshold: 0 to 50000 kA2-cycle in steps of 1 Reset delay: 0 to 65.535 s in steps of 0.001
Z0/Z1 angle: -90 to 90 in steps of 1
Fault duration accuracy: 0.25 of a power cycle Time accuracy: 3% or 4 ms, whichever is greater
Zero-sequence mutual compensation
Availability: 1 per CT bank with a minimum of 2 Operate time: < 30 ms at 60 Hz
Z0M/Z1 magnitude: 0.00 to 7.00 in steps of 0.01
Z0M/Z1 angle: -90 to 90 in steps of 1 LOSS OF EXCITATION
Right blinder (Quad only):
Reach: 0.02 to 500 in steps of 0.01 Operating condition: Positive-sequence impedance
Characteristic angle: 60 to 90 in steps of 1 Characteristic: 2 independent offset mho circles
Left blinder (Quad only): Center: 0.10 to 300.0 (sec.) in steps of 0.01
Reach: 0.02 to 500 in steps of 0.01 Radius: 0.10 to 300.0. (sec.) in steps of 0.01
Characteristic angle: 60 to 90 in steps of 1 Reach accuracy: 3%
Time delay: 0.000 to 65.535 s in steps of 0.001 Undervoltage supervision
Level: 0.000 to 1.250 pu in steps of 0.001
Accuracy: 0.5% of reading from 10 to 208V
Pickup delay: 0 to 65.535 s in steps of 0.001
Timing accuracy: 3% or 20 ms, whichever is greater
Operate time: <50 ms

22-8 BuyLog Catalog www.gedigitalenergy.com Rev. 11/13


Data subject to change
without notice
Relays and Meters Section 22
Protection & Control
UR & URPlus
UR Technical Specifications, continued
PROTECTION PROTECTION PROTECTION
MECHANICAL JAM OPEN POLE DETECTOR Memory duration: 5 to 25 cycles in steps of 1
VT location: all delta-wye and wye-delta
Operating condition: Phase overcurrent Detects an open pole condition, monitoring breaker auxiliary con- transformers
Arming condition: Motor not starting tacts, the current in each phase and optional voltages on the line CT location: all delta-wye and wye-delta
Pickup level: 1.00 to 10.00 FLA in steps of 0.01 Current pickup level: 0.000 to 30.000 pu in steps of 0.001 transformers
Dropout level: 97 to 98% of pickup Line capacitive 300.0 to 9999.9 sec. W in steps of 0.1 Voltage supervision 0 to 5.000 pu in steps of 0.001
Level accuracy: at 0.1 to 2.0 CT: 0.5% of reading reactances (XC1, XC0): pickup (series
at > 2.0 CT rating: 1.5% of reading Remote current 0.000 to 30.000 pu in steps of 0.001 compensation
Pickup delay: 0.10 to 600.00 s in steps of 0.01 pickup level: applications):
Reset delay: 0.00 to 600.00 s in steps of 0.01 Current dropout level: Pickup + 3%, not less than 0.05 pu
Time accuracy: 3% or 20 ms, whichever is greater PHASE DISTANCE OPERATING TIME CURVES
OVERFREQUENCY
MOTOR START SUPERVISION The operating times are response times of a microprocessor part
Pickup level: 20.00 to 65.00 Hz in steps of 0.01 of the relay. See output contacts specifications for estimation of
Maximum no. of starts: 1 to 16 in steps of 1 Dropout level: Pickup - 0.03 Hz the total response time for a particular application. The operating
Monitored time interval: 1 to 300 minutes in steps of 1 Level accuracy: 0.01 Hz times are average times including variables such as fault incep-
Time between starts: 0 to 300 minutes in steps of 1 Time delay: 0 to 65.535 s in steps of 0.001 tion angle or type of a voltage source (magnetic VTs and CVTs).
Restart delay: 0 to 50000seconds in steps of 1 Timer accuracy: 3% or 4 ms, whichever is greater
NEGATIVE SEQUENCE DIRECTIONAL OC PHASE COMPARISON PROTECTION (87PC)
Directionality: Co-existing forward and reverse Signal Selection: Mixed I_2 - K x I_1 (K=0.00 to 0.25 in
Polarizing: Voltage steps of 0.01, or3I_0)
Polarizing voltage: V_2 Angle Reference: 0 to 360 leading in steps of 1
Operating current: I_2 or I_0 Fault detector low:
Level sensing: Instantaneous 0.02 to 15.00 pu in steps of 0.01
Zero-sequence: |I_0| - K |I_1| Overcurrent:
Negative-sequence: |I_2| - K |I_1| I2 x Z - V2: 0.005 to 15.00 pu in steps of 0.01
Restraint, K: 0.000 to 0.500 in steps of 0.001 dI2 / dt: 0.01 to 5.00 pu in steps of 0.01
Characteristic angle: 0 to 90 in steps of 1 dI1 / dt: 0.01 to 5.00 pu in steps of 0.01
Limit angle: 40 to 90 in steps of 1, independent for Fault detector High:
forward and reverse Instantaneous 0.10 to 15.00 pu in steps of 0.01
Angle accuracy: 2 Overcurrent:
Offset impedance: 0.00 to 250.00W in steps of 0.01 I2 x Z - V2: 0.005 to 15.00 pu in steps of 0.01
Pickup level: 0.05 to 30.00 pu in steps of 0.01 dI2 / dt: 0.01 to 5.00 pu in steps of 0.01
Dropout level: 97 to 98% dI1 / dt: 0.01 to 5.00 pu in steps of 0.01
Operation Time: < 16 ms at 3 Pickup at 60 Hz Signal Symmetry -0.5 to 5.0 ms in steps of 0.1
NEGATIVE SEQUENCE IOC Adjustment: PHASE/NEUTRAL/GROUND IOC
Channel Delay Adjustment: 0.000 to 30.00 ms in steps of 0.001 Pickup level: 0.000 to 30.000 pu in steps of 0.001
Current: Phasor Channel Adjustments: channel delay and signal symmetry
Pickup level: 0.000 to 30.000 pu in steps of 0.001 Dropout level: 97 to 98% of pickup
compensation Level accuracy:
Dropout level: 97 to 98% of Pickup Operate Time (Typical): 3/4 cycle for single phase comparison
Level accuracy: 0.1 to 2.0 CT rating: 0.5% of reading or 1% of rated
Trip Security: First coincidence or enhanced (whichever is greater)
0.1 to 2.0 CT rating: 0.5% of reading or 1% of rated Second Coincidence Timer: 10 to 200 ms in steps of 1
(whichever is greater)> 2.0 CT rating: > 2.0 CT rating: 1.5% of reading
Enhanced Stability Angle: 40 to 180 in steps of 1 Overreach: <2%
1.5% of reading
Overreach: < 2% PHASE DIRECTIONAL OVERCURRENT Pickup delay: 0.00 to 600.00 s in steps of 0.01
Pickup delay: 0.00 to 600.00 s in steps of 0.01 Reset delay: 0.00 to 600.00 s in steps of 0.01
Relay connection: 90 (quadrature) Operate time: <16ms at 3 pickup at 60Hz
Reset delay: 0.00 to 600.00 s in steps of 0.01 Quadrature voltage:
Operate time: < 20 ms at 3 Pickup at 60 Hz (Phase/Ground IOC) <20ms at 3
ABC phase seq.: phase A (VBC), phase B (VCA), phase C pickup at 60Hz (Neutral IOC)
Timing accuracy: Operate at 1.5 Pickup 3% or 4 ms (VAB)
(whichever is greater) Timing accuracy: Operate at 1.5 Pickup 3% or 4 ms
ACB phase seq.: phase A (VCB), phase B (VAC), phase C (whichever is greater)
NEGATIVE SEQUENCE OVERVOLTAGE (VBA)
Polarizing voltage 0.000 to 3.000 pu in steps of 0.001 PHASE/NEUTRAL/GROUND TOC
Pickup level: 0.000 to 1.250 pu in steps of 0.001 threshold:
Dropout level: 97 to 98% of Pickup Current: Phasor or RMS
Current sensitivity threshold:0.05 pu Pickup level: 0.000 to 30.000 pu in steps of 0.001
Level accuracy: 0.5% of reading from 10 to 208 V Characteristic angle: 0 to 359 in steps of 1
Pickup delay: 0 to 600.00 s in steps of 0.01 Dropout level: 97% to 98% of Pickup
Angle accuracy: 2 Level accuracy: for 0.1 to 2.0 CT: 0.5% of reading or
Reset delay: 0 to 600.00 s in steps of 0.01 Operation time: (FlexLogic elements):
Time accuracy: 3% or 20 ms, whichever is greater 1% of rated (whichever is greater) for
Tripping (reverse load, forward fault): < 12 ms, typically > 2.0 CT: 1.5% of reading > 2.0 CT
Operate time: < 30 ms at 1.10 Pickup at 60 Hz Blocking (forward load, reverse fault): < 8 ms, typically rating
NEGATIVE SEQUENCE TOC PHASE DISTANCE Curve shapes: IEEE Moderately/Very/Extremely
Current: Phasor Inverse; IEC (and BS) A/B/C and Short
Characteristic: Mho (memory polarized or offset) or Inverse; GE IAC Inverse, Short/Very/
Pickup level: 0.000 to 30.000 pu in steps of 0.001 Quad (memory polarized or non-direc-
Dropout level: 97% to 98% of Pickup Extremely Inverse; I2t; FlexCurves.
tional), selectable individually per zone (programmable); Definite Time
Level accuracy: 0.5% of reading or 1% of rated Number of zones: Up to 5
(whichever is greater from 0.1 to 2.0 x CT (0.01 s base curve)
Directionality: Forward, Reverse, or Non-Directional Curve multiplier: Time Dial = 0.00 to 600.00
rating 1.5% of reading > 2.0 x CT rating per zone
Curve shapes: IEEE Moderately/Very/Extremely in steps of 0.01
Reach (secondary W): 0.02 to 250.00 in steps of 0.01 Reset type: Instantaneous/Timed (per IEEE)
Inverse; IEC (and BS) A/B/C and Short Reach accuracy: 5% including the effect of CVT
Inverse; GE IAC Inverse, Timing accuracy: Operate at > 1.03 actual Pickup
transients up to an SIR of 30 3.5% of operate time or cycle
Short/Very/Extremely Inverse; I2t; Distance:
FlexCurves. (programmable); Definite (whichever is greater)
Characteristic angle: 30 to 90 in steps of 1
Time (0.01 s base curve) Comparator limit angle: 30 to 90 in steps of 1 PHASE OVERVOLTAGE
Curve multiplier (Time dial): 0.00 to 600.00 in steps of 0.01 Directional supervision:
Reset type: Instantaneous/Timed (per IEEE) and L ear Voltage: Phasor only
Characteristic angle: 30 to 90 in steps of 1 Pickup level: 0.000 to 3.000 pu in steps of 0.001
Timing accuracy: Operate at > 1.03 Actual Pickup Limit angle: 30 to 90 in steps of 1
3.5% of operate time or cycle Dropout level: 97 to 98% of Pickup
Right blinder (Quad only): Level accuracy: 0.5% of reading from 10 to 208V
(whichever is greater) Reach: 0.02 to 500 in steps of 0.01
Operate time: < 30 ms at 1.10 Pickup at 60 Hz Pickup delay: 0.00 to 600.00 in steps of 0.01 s
Characteristic angle: 60 to 90 in steps of 1 Operate time: < 30 ms at 1.10 Pickup at 60 Hz
NEUTRAL DIRECTIONAL OVERCURRENT Left Blinder (Quad only): Timing accuracy: 3% or 4 ms (whichever is greater)
Directionality: Co-existing forward and reverse Reach: 0.02 to 500 in steps of 0.01
Characteristic angle: 60 to 90 in steps of 1 PHASE UNDERVOLTAGE
Polarizing: Voltage, Current, Dual
Polarizing voltage: V_0 or VX Time delay: 0.000 to 65.535 s in steps of 0.001 Voltage: Phasor only
Polarizing current: IG Timing accuracy: 3% or 4 ms, whichever is greater Pickup level: 0.000 to 3.000 pu in steps of 0.001
Operating current: I_0 Current supervision: Dropout level: 102 to 103% of Pickup
Level sensing: 3 (|I_0| - K |I_1|), IG Level: line-to-line current Level accuracy: 0.5% of reading from 10 to 208V
Restraint, K: 0.000 to 0.500 in steps of 0.001 Pickup: 0.050 to 30.000 pu in steps of 0.001 Curve shapes: GE IAV Inverse; Definite Time
Characteristic angle: -90 to 90 in steps of 1 Dropout: 97 to 98% (0.1s base curve)
Limit angle: 40 to 90 in steps of 1, independent for Curve multiplier: Time Dial = 0.00 to 600.00
forward and reverse in steps of 0.01
Angle accuracy: 2 Timing accuracy: Operate at < 0.90 Pickup 3.5%
Offset impedance: 0.00 to 250.00W in steps of 0.01 of operate time or 4 ms
Pickup level: 0.05 to 30.00 pu in steps of 0.01 (whichever is greater)
Dropout level: 97 to 98% PILOT-AIDED SCHEMES
Operation time: < 16 ms at 3 Pickup at 60 Hz
Direct Underreaching Transfer Trip (DUTT)
NEUTRAL OVERVOLTAGE Permissive Underreaching Transfer Trip (PUTT)
Pickup level: 0.000 to 3.000 pu in steps of 0.001 Permissive Overreaching Transfer Trip (POTT)
Dropout level: 97 to 98% of Pickup Hybrid POTT Scheme
Level accuracy: 0.5% of reading from 10 to 208 V Directional Comparison Blocking Scheme
Pickup delay: 0.00 to 600.00 s in steps of 0.01
Reset delay: 0.00 to 600.00 s in steps of 0.01
Timing accuracy: 3% or 20 ms (whichever is greater)
Operate time: < 30 ms at 1.10 Pickup at 60 Hz

Rev. 11/13 www.gedigitalenergy.com BuyLog Catalog 22-9


Data subject to change
without notice
Relays and Meters Section 22
Protection & Control
UR & URPlus
UR Technical Specifications, continued
PROTECTION PROTECTION PROTECTION
POWER SWING DETECT THERMAL MODEL TRIP OUTPUT
Functions: Power swing block, Out-of-step trip Thermal overload curves: Standard curve, FlexCurve, Collects trip and reclose input requests and issues outputs
Characteristic: Mho or Quad voltage dependent curve to control tripping and reclosing.
Measured impedance: Positive-sequence Standard Curve 0.00 to 600.00 in steps of 0.01 Communications 0 to 65535 s in steps of 0.001
Blocking/tripping mozes: 2-step or 3-step Time Multiplier: timer delay:
Tripping mode: Early or Delayed Thermal Overload Pickup: pu = overload factor x FLA Evolving fault timer: 0.000 to 65.535 s in steps of 0.001
Current supervision: Overload (OF): 1.00 to 1.50 in steps of 0.001 Timing accuracy: 3% or 4 ms, whichever is greater
Pickup level: 0.050 to 30.000 pu in steps of 0.001 Standard Overload Curve:
trip time = UNDERFREQUENCY
Dropout level: 97 to 98% of Pickup
Fwd / reverse reach 0.10 to 500.00W in steps of 0.01 TD x 2.2116623 Minimum signal: 0.10 to 1.25 pu in steps of 0.01
I I
motor 2 motor Pickup level: 20.00 to 65.00 Hz in steps of 0.01
(sec. W):
Left and right blinders 0.10 to 500.00W in steps of 0.01 ( )
0.02530337 x OF x FLA + 0.05054758 x OF x FLA Dropout level: Pickup + 0.03 Hz
(sec. W): Motor Rated Voltage: 1 to 50000 V in steps of 1 Level accuracy: 0.01 Hz
Impedance accuracy: 5% Thermal Motor Biasing: Current unbalance, RTDs Time delay: 0 to 65.535 s in steps of 0.001
Fwd / reverse 40 to 90 in steps of 1 Thermal Model 1 power cycle Timer accuracy: 3% or 4 ms, whichever is greater
angle impedances: Update Rate: VOLTS PER HERTZ
Angle accuracy: 2 Stopped/Running Time 1 to 65000 min. in steps of 1
Characteristic limit angles: 40 to 140 in steps of 1 Cool Constants: Voltage: Phasor only
Timers: 0.000 to 65.535 s in steps of 0.001 Stopped/Running Time Exponential Pickup level: 0.80 to 4.00 in steps of 0.01 pu V/Hz
Timing accuracy: 3% or 4 ms, whichever is greater Cool Constants Decay: Dropout level: 97 to 98% of Pickup
Hot/Cold Safe Stall Ratio: 0.01 to 1.00 in steps of 0.01 Level accuracy: 0.02 pu
RATE OF CHANGE OF FREQUENCY Timing curves: Definite Time; Inverse A, B, and C,
Current Accuracy: Per phase current inputs
df/dt trend: increasing, decreasing, bi-directional Current Source: True RMS FlexCurves. A, B, C, and D
df/dt pickup level: 0.10 to 15.00 Hz/s in steps of 0.01 Timing Accuracy 100 ms or 2% whichever is greater TD Multiplier: 0.05 to 600.00 s in steps of 0.01
df/dt dropout level: 96% of pickup Timing Accuracy 100 ms or 4%, whichever is greater Reset delay: 0.0 to 1000.0 s in steps of 0.1
df/dt level accuracy: 80 mHz/s or 3.5%, whichever is greater for Voltage Timing accuracy: 3% or 4 ms (whichever is greater)
Overvoltage supv.: 0.100 to 3.000 pu in steps of 0.001 Dependent Overload: VT FUSE FAIL
Overcurrent supv.: 0.000 to 30.000 pu in steps of 0.001
Pickup delay: 0 to 65.535 s in steps of 0.001 THIRD HARMONIC NEUTRAL UNDERVOLTAGE Monitored parameters: V_2, V_1, I_1
Reset delay: 0 to 65.535 s in steps of 0.001 Operating quantity: 3rd harmonic of auxiliary undervoltage WATTMETRIC ZERO-SEQUENCE DIRECTIONAL
Time accuracy: 3% or 4 ms, whichever is greater Undervoltage: Measured Power Zero-Sequence
95% settling time for df/dt: < 24 cycles Pickup level: 0.000 to 3.000 pu in steps of 0.001 Number of Elements: 2
Operate time: Dropout level: 102 to 103% of pickup Characteristic Angle: 0 to 360 in steps of 1
at 2 pickup: 12 cycles Accuracy: 2% of reading from 1 to 120V Minimum Power: 0.001 to 1.20pu in steps of 0.001
at 3 pickup: 8 cycles Power: Pickup Level Accuracy: 1% or 0.0025 pu,
at 5 pickup: 6 cycles Pickup level: 0.000 to 1.200 pu in steps of 0.001 whichever is greater
Dropout level: 97 to 98% of pickup
RESTRICTED GROUND FAULT Pickup Delay: Definite time (0 to 600.00 s in steps of
Accuracy: 5% or 0.01 pu, whichever is greater
Pickup: 0.000 to 30.000 pu in steps of 0.001 0.01), inverse time, or FlexCurve
Undervoltage Inhibit 0.000 to 3.000 pu in steps of 0.001 pu
Dropout: 97 to 98% of Pickup Inverse Time Multiplier: 0.01 to 2.00 s in steps of 0.01
Level:
Slope: 0 to 100% in steps of 1% Time Accuracy: 3% or 8 ms, whichever is greater
Accuracy: 0.5% of reading from 10 to 208V
Pickup delay: 0 to 600.00 s in steps of 0.01 Operate Time: <30 ms at 60 Hz
Pickup delay: 0 to 600.00 s in steps of 0.01
Dropout delay: 0 to 600.00 s in steps of 0.01 Time accuracy: 3% or 20 ms, whichever is greater
Operate time: < 1power system cycle Operate time: < 30 ms at 1.10 pickup at 60 Hz MONITORING
SENSITIVE DIRECTIONAL POWER TRANSFORMER AGING FACTOR DATA LOGGER
Measured power: 3-phase, true RMS Operating quantity: computed aging accelaration factor (pu) Number of channels: 1 to 16
Number of stages: 2 Pickup level: 1 to 10 pu in steps of 0.1 Parameters: Any available analog actual value
Characteristic angle: 0 to 359 in steps of 1 Pickup delay: 0 to 30000 min. in steps of 1 Sampling rate: 15 to 3600000 ms in steps of 1
Calibration angle: 0.00 to 0.95 in steps of 0.05 Trigger: Any FlexLogic operand
Minimum power: -1.200 to 1.200 pu in steps of 0.001 TRANSFORMER INSTANTANEOUS DIFFERENTIAL Mode: Continuous or Triggered
Pickup level accuracy: 1% or 0.001 pu, whichever is greater Pickup level: 2.00 to 30.00 pu in steps of 0.01 Storage capacity: (NN is dependent on memory)
Hysteresis: 2% or 0.001 pu, whichever is greater Dropout level: 97 to 98% of pickup 1-second rate: 01 channel for NN days
Pickup delay: 0 to 600.00 s in steps of 0.01 Level accuracy: 0.5% of reading or 1% of rated 16 channels for NN days
Time accuracy: 3% or 4 ms, whichever is greater (whichever is greater) 60-minute rate: 01 channel for NN days
Operate time: 50 ms Operate time: < 20 ms at 3 pickup at 60 Hz 16 channels for NN days
SPLIT PHASE PROTECTION TRANSFORMER HOTTEST-SPOT TEMPERATURE EVENT RECORDER
Operating quantity: split phast CT current biased by gener- Operating quantity: computed temperature in C Capacity: 1024 events
ator load current Pickup level: 50 to 300C in steps of 1 Time-tag: to 1 microsecond
Pickup level: 0.000 to 1.500 pu in steps of 0.001 Dropout level: 1C below pickup Triggers: Any element pickup, dropout or operate
Dropout level: 97 to 98% of pickup Pickup delay: 0 to 30000 min. in steps of 1 Digital input change of state Digital
Level accuracy: 0.5% of reading or 1% of rated output change of state Self-test events
TRANSFORMER LOSS OF LIFE Data storage: In non-volatile memory
Pickup delay: 0.000 to 65.535 s in steps of 0.001
Time accuracy: 3% of cycles, whichever is greater Operating quantity: computed accumulated transformer
FAULT LOCATOR
Operate time: < 5 cycles at 1.10 x pickup at 60Hz loss of life, in hours
Pickup level: 0 to 500000 hours in steps of 1 Method: Single-ended
STATOR DIFFERENTIAL Maximum accuracy if: Fault resistance is zero or fault currents
TRANSFORMER PERCENT DIFFERENTIAL from all line terminals are in phase
Pickup: 0.050 to 1.00 pu in steps of 0.01
Slope 1/2: 1 to 100% in steps of 1 Characteristic: Differential Restraint pre-set Relay accuracy: 1.5% (V > 10 V, I > 0.1 pu)
Break 1: 1.00 to 1.50 pu in steps of 0.01 Number of zones: 2 Worst-case accuracy: VT%error + (user data)
Break 2: 1.50 to 30.00 pu in steps of 0.01 Minimum pickup: 0.05 to 1.00 pu in steps of 0.001 CT%error + (user data)
Level accuracy: 2% Slope 1 range: 15 to 100% in steps of 1% ZLine%error + (user data)
Slope 2 range: 50 to 100% in steps of 1% METHOD%error + (Chapter 6)
SYNCHROCHECK Kneepoint 1: 1.0 to 2.0 pu in steps of 0.0001 RELAY ACCURACY%error + (1.5%)
Max voltage difference: 0 to 400000 V in steps of 1 Kneepoint 2: 2.0 to 30.0 pu in steps of 0.0001 HIGH-IMPEDANCE FAULT DETECTION (HiZ)
Max angle difference: 0 to 100 in steps of 1 2nd harmonic 1.0 to 40.0% in steps of 0.1
Max freq. difference: 0.00 to 2.00 Hz in steps of 0.01 inhibit level: Detections: Arc Suspected, Arc Detected, Downed
Hysteresis for 0.00 to 0.10 Hz in steps of 0.01 2nd harmonic Adaptive, Traditional, Disabled Conductor, Phase Identification
max. freq. diff.: inhibit function: OSCILLOGRAPHY
Dead source function: None, LV1 & DV2, DV1 & LV2, DV1 or 2nd harmonic Per-phase, 2-out-of-3, Average
DV2, DV1 xor DV2, DV1 & DV2 (L = Live, inhibit mode: Maximum records: 64
D = Dead) 5th harmonic 1.0 to 40.0% in steps of 0.1 Sampling rate: 64 samples per power cycle
inhibit range: Triggers: Any element pickup, dropout
Operate times: or operate
Harmonic inhibits 20 to 30 ms Digital input change of state
selected: Digital output change of state
No harmonic 5 to 20 ms Any FlexLogic Operand
inhibits selected: FlexLogic Equation
Dropout level: 97 to 98% of pickup Data: AC input channels
Level accuracy: 0.5% of reading or 1% of rated Element state
(whichever is greater) Digital input state
Digital output state
Data storage: In non-volatile memory
USER-PROGRAMMABLE FAULT REPORT
Number of elements: 2
Pre-fault trigger: any FlexLogic. operand
Fault trigger: any FlexLogic. operand
Recorder quantities: 32 (any FlexAnalog value)

22-10 BuyLog Catalog www.gedigitalenergy.com Rev. 11/13


Data subject to change
without notice
Relays and Meters Section 22
Protection & Control
UR & URPlus
UR Technical Specifications, continued
MONITORING USER-PROGRAMMABLE ELEMENTS INPUTS
PHASOR MEASUREMENT UNIT CONTROL PUSHBUTTONS AC CURRENT
Output format: per IEEE C37.118 standard Number of pushbuttons: 3 (standard) or 16 (optional) CT rated primary: 1 to 50000 A
Number of channels: 14 synchrophasors, 16 analogs, Operation: drive FlexLogic. operands CT rated secondary: 1 A or 5 A by connection
16 digitals Nominal frequency: 20 to 65 Hz
FLEXCURVES
TVE (total vector error): <1% Relay burden: < 0.2 VA at rated secondary
Triggering: frequency, voltage, current, power, rate Number: 4 (A through D) Conversion range:
of change of frequency, user-defined Reset points: 40 (0 through 1 of pickup) Standard CT: 0.02 to 46 CT rating RMS symmetrical
Reporting rate: 1, 2, 5, 10, 12, 15, 20, 25, 30, 50, 60 or Operate points: 80 (1 through 20 of pickup) Sensitive Ground/ 0.002 to 4.6 CT rating
120 times per second Time delay: 0 to 65535 ms in steps of 1 HI-Z CT module: RMS symmetrical
Number of clients: One over TCP/IP port, two over UDP/IP FLEXLOGIC Current withstand: 20 ms at 250 times rated
ports 1 sec. at 100 times rated
TAC ranges: As indicated in appropriate specifica- Programming language: Reverse Polish Notation with graphical continuous at 3 times rated
tions sections visualization (keypad programmable)
Lines of code: 512 AC VOLTAGE
Network reporting 16-bit integer or 32-bit IEEE floating
format: point numbers Internal variables: 64 VT rated secondary: 50.0 to 240.0 V
Network reporting style: Rectangular (real and imaginary) or Supported operations: NOT, XOR, OR (2 to 16 inputs), AND (2 to VT ratio: 1.00 to 24000.00
polar (magnitude and angle) 16 inputs), NOR (2 to 16 inputs), Nominal frequency: 20 to 65 Hz For the L90, the nominal
coordinates NAND (2 to 16 inputs), Latch (Reset system frequency should be chosen as
Filtering: P and M class Dominant), Edge Detectors, Timers 50 Hz or 60 Hz only.
Calibration: Angle 5, magnitude +/-5% per phase Inputs: any logical variable, contact, Relay burden: < 0.25 VA at 120 V
Compensation: -180 to 180 in steps of 30 or virtual input Conversion range: 1 to 275 V
(current and voltage components) Number of timers: 32 Voltage withstand: continuous at 260 V to neutral
Mode of operation: Normal and test Pickup delay: 0 to 60000 (ms, sec., min.) in steps of 1 1 min./hr at 420 V to neutral
PMU Recording: 46 configurable channels (14 Dropout delay: 0 to 60000 (ms, sec., min.) in steps of 1
CONTACT INPUTS
syncrophasor, 16 digital, 16 analogs) FLEXELEMENTS Dry contacts: 1000 maximum
METERING Number of elements: 8 or 16 Wet contacts: 300 V DC maximum
Operating signal: any analog actual value, or two values Selectable thresholds: 17 V, 33 V, 84 V, 166 V
RMS CURRENT: PHASE, NEUTRAL, AND GROUND in Differential mode Tolerance: 10%
Accuracy at: Operating signal mode: Signed or Absolute Value Contacts Per 4
0.1 to 2.0 CT rating: 0.25% of reading or 0.1% of rated Operating mode: Level, Delta Common Return:
(whichever is greater) Comparator direction: Over, Under Recognition time: < 1 ms
> 2.0 CT rating: 1.0% of reading Pickup Level: -30.000 to 30.000 pu in steps of 0.001 Debounce timer: 0.0 to 16.0 ms in steps of 0.5
RMS VOLTAGE Hysteresis: 0.1 to 50.0% in steps of 0.1 Continuous Current Draw: 3mA (when energized)
Delta dt: 20 ms to 60 days
Accuracy: 0.5% of reading from 10 to 208 V Pickup & dropout delay: 0.000 to 65.535 s in steps of 0.001 CONTACT INPUTS WITH AUTO-BURNISHING
REAL POWER (WATTS) Dry contacts: 1000 maximum
FLEXSTATES
Accuracy: 1.0% of reading at -0.8 < PF < -1.0 and Wet contacts: 300 V DC maximum
Number: up to 256 logical variables grouped Selectable thresholds: 17 V, 33 V, 84 V, 166 V
0.8 < PF < 1.0 under 16 Modbus addresses Tolerance: 10%
REACTIVE POWER (VARS) Programmability: any logical variable, contact, Contacts Per 2
or virtual input Common Return:
Accuracy: 1.0% of reading at -0.2 < PF < 0.2
LED TEST Recognition time: < 1 ms
APPARENT POWER (VA) Debounce timer: 0.0 to 16.0 ms in steps of 0.5
Initiation: from any digital input or user-program- Continuous Current Draw: 3mA (when energized)
Accuracy: 1.0% of reading mable condition Auto-Burnish 50 to 70 mA
WATT-HOURS (POSITIVE AND NEGATIVE) Number of tests: 3, interruptible at any time Impulse Current:
Accuracy: 2.0% of reading Duration of full test: approximately 3 minutes Duration of 25 to 50 ms
Range: 0 to 2 109 MWh Test sequence 1: all LEDs on Auto-Burnish Impulse:
Parameters: 3-phase only Test sequence 2: all LEDs off, one LED at a time on for 1 s
Test sequence 3: all LEDs on, one LED at a time off for 1 s DCMA INPUTS
Update rate: 50 ms
NON-VOLATILE LATCHES Current input (mA DC): 0 to -1, 0 to +1, -1 to +1, 0 to 5, 0 to 10,
VAR-HOURS (POSITIVE AND NEGATIVE) 0 to 20, 4 to 20 (programmable)
Accuracy: 2.0% of reading Type: Set-dominant or Reset-dominant Input impedance: 379 10%
Range: 0 to 2 109 Mvarh Number: 16 (individually programmed) Conversion range: -1 to + 20 mA DC
Parameters: 3-phase only Output: Stored in non-volatile memory Accuracy: 0.2% of full scale
Update rate: 50 ms Execution sequence: As input prior to protection, control, and Type: Passive
FlexLogic.
CURRENT HARMONICS DIRECT INPUTS
SELECTOR SWITCH
Harmonics: 2nd to 25th harmonic: per phase, dis- Number of input points: 32
played as a % of f1 (fundamental fre- Number of elements: 2 No. of remote devices: 16
quency phasor) THD: per phase, Upper position limit: 1 to 7 in steps of 1 Default states on On, Off, Latest/Off, Latest/On
displayed as a % of f1 Selecting mode: Time-out or Acknowledge loss of comms.:
Accuracy: Time-out timer: 3.0 to 60.0 s in steps of 0.1 Ring configuration: Yes, No
Harmonics: 1. f1 > 0.4pu: (0.20% + 0.035% / har- Control inputs: step-up and 3-bit Data rate: 64 or 128 kbps
monic) of reading or 0.15% of 100%, Power-up mode: restore from non-volatile memory or CRC: 32-bit
whichever is greater synchronize to a 3-bit control input CRC alarm:
2. f1 < 0.4pu: as above plus %error of f1 USER-DEFINABLE DISPLAYS Responding to: Rate of messages failing the CRC
THD: 1. f1 > 0.4pu: (0.25% + 0.035% / har- Monitoring message count: 10 to 10000 in steps of 1
Number of displays: 16
monic) of reading or 0.20% of 100%, Alarm threshold: 1 to 1000 in steps of 1
Lines of display: 2 20 alphanumeric characters
whichever is greater Unreturned message alarm:
Parameters: up to 5, any Modbus register addresses
2. f1 < 0.4pu: as above plus %error of f1 Responding to: Rate of unreturned messages in the
Invoking and scrolling: keypad, or any user-programmable ring configuration
DEMAND condition, including pushbuttons Monitoring 10 to 10000 in steps of 1
Measurements: Phases A, B, and C present and maxi- USER-PROGRAMMABLE LEDS message count:
mum measured currents Alarm threshold: 1 to 1000 in steps of 1
3-Phase Power (P, Q, and S) present and Number: 48 plus Trip and Alarm
Programmability: from any logical variable, contact, or IRIG-B INPUT
maximum measured currents virtual input
Accuracy: 2.0% Amplitude modulation: 1 to 10 V pk-pk
Reset mode: Self-reset or Latched DC shift: TTL
FREQUENCY USER-PROGRAMMABLE PUSHBUTTONS (OPTIONAL) Input impedance: 22 kW
Accuracy at Isolation: 2 kV
Number of pushbuttons: 12
V = 0.8 to 1.2 pu: 0.01 Hz (when voltage signal is used Mode: Self-Reset, Latched REMOTE INPUTS (IEC 61850 GSSE)
for frequency measurement) Display message: 2 lines of 20 characters each
I = 0.1 to 0.25 pu: 0.05 Hz Number of input points: 32, configured from
I > 0.25 pu: 0.02 Hz (when current signal is used 8-BIT SWITCH 64 incoming bit pairs
for frequency measurement) Number of elements: 6 Number of remote devices: 16
Input signals: two 8-bit integers via FlexLogic Default states on On, Off, Latest/Off, Latest/On
VOLTAGE HARMONICS
operands loss of comms.:
Harmonics: 2nd to 25th harmonic: per phase, dis-
played as a % of f1 (fundamental fre- Control: any FlexLogic operand RTD INPUTS
quency phasor) THD: per phase, Response time: < 8 ms at 60 Hz, < 10 ms at 50 Hz Types (3-wire): 100 Platinum, 100 &
displayed as a % of f1 120 Nickel, 10 Copper
Accuracy: Sensing current: 5 mA
Harmonics: 1. f1 > 0.4pu: (0.20% + 0.035% / Range: -50 to +250C
harmonic) of reading or 0.15% of 100%, Accuracy: 2C
whichever is greater Isolation: 36 V pk-pk
2. f1 < 0.4pu: as above plus %error of f1
THD: 1. f1 > 0.4pu: (0.25% + 0.035% /
harmonic) of reading or 0.20% of 100%,
whichever is greater
2. f1 < 0.4pu: as above plus %error of f1

Rev. 11/13 www.gedigitalenergy.com BuyLog Catalog 22-11


Data subject to change
without notice
Relays and Meters Section 22
Protection & Control
UR & URPlus
UR Technical Specifications, continued
OUTPUTS COMMUNICATIONS INTER-RELAY COMMUNICATIONS
* Note: Typical distances listed are based on the following
CONTROL POWER EXTERNAL OUTPUT RS232 assumptions for system loss. Actual losses will vary from one
(FOR DRY CONTACT INPUT) Front port: 19.2 kbps, Modbus RTU, DNP 3.0 installation to another, the distance covered by your system
Capacity: 100 mA DC at 48 V DC RS485 may vary.
Isolation: 300 Vpk
1 or 2 rear ports: Up to 115 kbps, Modbus RTU, DNP 3.0 CONNECTOR LOSSES (TOTAL OF BOTH ENDS)
DCMA OUTPUTS isolated together at 36 Vpk ST connector 2dB
Range: -1 to 1 mA, 0 to 1 mA, 4 to 20 mA Typical distance: 1200 m
Isolation: 2 kV FIBER LOSSES
Max. load resistance: 12 k for -1 to 1 mA range
12 k for 0 to 1 mA range 820 nm multimode 3 dB/km
ETHERNET PORT
600 for 4 to 20 mA range 1300 nm mulimode 1 dB/km
Accuracy: 0.75% of full-scale for 0 to 1 mA range 10Base-F: 820 nm, multi-mode, supports half- 1300 nm singlemode 0.35 dB/km
0.5% of full-scale for -1 to 1 mA range duplex/full-duplex fiber optic with ST 1550 nm singlemode 0.25 dB/km
0.75% of full-scale for 0 to 20 mA range connector Splice losses: One splice every 2 km,
99% Settling time to 100 ms Redundant 10Base-F: 820 nm, multi-mode, half-duplex/full- at 0.05 dB loss per splice
a step change: duplex fiber optic with ST connector
10Base-T: RJ45 connector SYSTEM MARGIN
Isolation: 1.5 kV
Driving signal: any FlexAnalog quantity Power budget: 10 dB 3 dB additional loss added to calculations to compensate for all
Upper & lower limit -90 to 90 pu in steps of 0.001 Max optical input power: -7.6 dBm other losses.
for the driving signal: Max optical -20 dBm Compensate difference in transmitting and receiving (channel
output power: asymmetry) channel delays using GPS satellite clock: 10 ms
DIRECT OUTPUTS Receiver sensitivity: -30 dBm
Output points: 32 Typical distance: 1.65 km POWER SUPPLY
SNTP clock <10 ms (typical)
FORM-A CURRENT MONITOR synchronization error: LOW RANGE
Threshold current: approx. 80 to 100 mA PROTOCOLS Nominal DC voltage: 24 to 48 V at 3 A
FORM-A RELAY Min/max DC voltage: 20 / 60 V
Make & carry for 0.2s: 30 A as per ANSI C37.90 * NOTE: Low range is DC only.
Carry continuous: 6A HIGH RANGE
Break at L/R of 40 ms: 1 A DC max. at 24 V
0.5 A DC max. at 48 V Nominal DC voltage: 125 to 250 V at 0.7 A
0.3 A DC max. at 125 V Min/max DC voltage: 88 / 300 V
0.2 A DC max. at 250 V Nominal AC voltage: 100 to 240 V at 50/60 Hz, 0.7 A
Operate time: < 4 ms Min/max AC voltage: 88 / 265 V at 48 to 62 Hz
Contact material: Silver alloy INTER-RELAY COMMUNICATIONS ALL RANGES
FORM-A VOLTAGE MONITOR Volt withstand: 2 Highest Nominal Voltage for 10 ms
SHIELDED TWISTED-PAIR INTERFACE OPTIONS
Applicable voltage: approx. 15 to 250 V DC Voltage loss hold-up: 50 ms duration at nominal
Trickle current: approx. 1 to 2.5 mA Power consumption: Typical = 15 VA; Max. = 30 VA
INTERNAL FUSE
RATINGS
* NOTE: RS422 distance is based on transmitter power and does Low range power supply: 8 A / 250 V
not take into consideration the clock source provided by the user. High range power supply: 4 A / 250 V
LINK POWER BUDGET INTERRUPTING CAPACITY
AC: 100 000 A RMS symmetrical
DC: 10 000 A
FORM-C AND CRITICAL FAILURE RELAY Hold up time: 200 ms
Make & carry for 0.2 s: 30 A
Carry continuous: 8A TYPE TESTS
Break at L/R of 40 ms: 0.25 A DC max. at 48 V
0.10 A DC max. at 125 V Electrical fast transient: ANSI/IEEE C37.90.1
Operate time: < 8 ms IEC 61000-4-4
Contact material: Silver alloy IEC 60255-22-4
Oscillatory transient: ANSI/IEEE C37.90.1
FAST FORM-C RELAY IEC 61000-4-12
Make & carry: 0.1 A max. (resistive load) Insulation resistance: IEC 60255-5
Minimum load impedance: Dielectric strength: IEC 60255-6
Operate time: < 0.6 ms ANSI/IEEE C37.90
* NOTE: These power budgets are calculated from the
Internal Limiting Resistor: 100, 2 Electrostatic discharge: EN 61000-4-2
manufacturers worst-case transmitter power and worst-case Surge immunity: EN 61000-4-5
IRIG-B OUTPUT receiver sensitivity. RFI susceptibility: ANSI/IEEE C37.90.2
Amplitude: 10 V peak-peak RS485 level MAXIMUM OPTICAL INPUT POWER IEC 61000-4-3
Maximum load: 100 ohms IEC 60255-22-3
Time delay: 1 ms for AM input Ontario Hydro C-5047-77
40 s for DC-shift input Conducted RFI: IEC 61000-4-6
Isolation: 2 kV Voltage dips/ IEC 61000-4-11
LATCHING RELAY interruptions/variations: IEC 60255-11
Power frequency IEC 61000-4-8
Make & carry for 0.2 s: 30 A as per ANSI C37.90 magnetic field immunity:
Carry continuous: 6A Vibration test (sinusoidal): IEC 60255-21-1
Break at L/R of 40 ms: 0.25 A DC max. Shock and bump: IEC 60255-21-2
Operate time: < 4 ms * NOTE: Type test report available upon re-
Contact material: Silver alloy TYPICAL LINK DISTANCE quest.
Control: separate operate and reset inputs
Control mode: operate-dominant or reset-dominant
PRODUCTION TESTS
REMOTE OUTPUTS (IEC 61850 GSSE)
Standard output points: 32 THERMAL
User output points: 32 Products go through an environmental test based upon an ac-
SOLID-STATE OUTPUT RELAY cepted quality level (AQL) sampling process
Operate & release time: <100 s
Maximum voltage: 265 V DC ENVIRONMENTAL
Maximum continuous 5 A at 45C; 4 A at 65C
current: OPERATING TEMPERATURES
Make & carry for 0.2 s: as per ANSI C37.90 Cold: IEC 60028-2-1, 16 h at -40C
For 0.3s: 300 A Dry Heat: IEC 60028-2-2, 16 h at +85C
Breaking capacity: OTHER
Humidity(noncondensing):
IEC is a registered trademark of Commission Electrotechnique In- IEC 60068-2-30, 95%, Variant 1,6days.
ternationale. IEEE is a registered trademark of the Institute of Altitude: Up to 2000 m
Electrical Electronics Engineers, Inc. Modbus is a registered trade- Installation Category: II
mark of Schneider Automation. NERC is a registered trademark of
North American Electric Reliability Council.GE, the GE monogram, Approvals
Multilin, FlexLogic, EnerVista and CyberSentry are trademarks of UL Listed for the USA and Canada
General Electric Company. Manufactured under an ISO9000 registered system.
GE reserves the right to make changes to specifications of prod-
ucts described at any time without notice and without obligation LVD 73/23/EEC: IEC 1010-1
to notify any person of such changes. EMC 81/336/EEC: EN 50081-2, EN 50082-2
Copyright 2013, General Electric Company.

22-12 BuyLog Catalog www.gedigitalenergy.com Rev. 11/13


Data subject to change
without notice
Relays and Meters Section 22
Protection & Control
SR Family
Comprehensive industrial and utility protective relay systems
for motors, generators, transformers, and feeders

Key Benefits
Large backlit display with 40 characters to view relay
information and settings in direct sunlight, full numerical
keypad, and setpoint navigation keys. (Except 735/737)
Accurate metering under severe system disturbances (750, 745
& 489) - Power system frequency tracking and adjusting
sampling rate accordingly
Minimize replacement time - Draw-out construction
Improve uptime of auxiliary equipment - Through I/O monitoring
Ease of use and installation - same front panel programming,
common cutout (Except 735/737)
Reduce troubleshooting time and maintenance costs -IRIG-B
time synchronization, event reports, waveform capture, data
logger (Except 735/737)
Simplify testing - Built in simulation features and unique
waveform play back functionality in the 745
Cost Effective Access information - Via Modbus RTU and DNP 3.0
Level 2 protocols, through standard RS232, RS485 & RS422 serial
ports, and optional Modbus RTU over TCP/IP through embedded
Ethernet Port to connect to 10MB Ethernet local or wide area
networks.
Complete asset monitoring - Analog I/O, metering including
Features (continued)
demand & energy (Except 735/737)
Follow technology evolution - Flash memory for product User Interface and Programming
field upgrade (Except 735/737 that requires an EEPROM Front Panel LEDs, full key pad, and backlit LCD display
replacement) RS232, RS485 and RS422 ports - up to 19,200 bps
Long lasting life - When exposed to chemically corrosive and Ethernet port - 10 Mbs
humid environments with optional conformal coating Multiple protocols - ModBus RTU, ModBus RTU over TCP/IP,
(Except 735/737) DNP 3.0 Level 2, Optional Device Net on 469
EnerVista Software
State of the art software for configuration and commissioning
Applications GE Multilin products
735/737 - Feeder Protection Document and software archiving toolset to ensure reference
750/760 - Feeder Protection (comprehensive) material and device utilities are up-to-date
469 - Motor Protection EnerVista Integrator providing easy integration of data
745 - Transformer Protection in the SR relays into new or existing monitoring and
489 - Generator Protection control systems

Features
Monitoring and Metering
Event recorder
Oscillography and Data Logger
Self diagnostic
Metering
Demand

Rev. 11/13 www.gedigitalenergy.com BuyLog Catalog 22-13


Data subject to change
without notice
Relays and Meters Section 22
Protection & Control
650 Family
Advanced Protection Control and Monitoring System

Key Benefits
Unique built-in control features - Comprehensive protection plus
programmable logic
Flexible and cost effective control for complex systems - Use IEC
compatible programmable logic to customize the functionality
of your protection & control system to address unique, site
specific applications
Human machine interface (HMI) - Standard backlit LCD display
with 4 x 20, optional 16 x 40 (240 x 128 pixels) graphical LCD,
programmable buttons, and rotary knob for selecting setting
menus, and submenus.
Minimize replacement time - Modular with card
draw-out construction
Reduce troubleshooting time and maintenance costs -
IRIG-B time synchronization, event reports, waveform capture,
data logger
Cost Effective Access information - Via multiple protocols,
through standard RS232, & RS485, Ethernet Ports.
Optimal integration flexibility via open standard protocols - Mod-
bus RTU, DNP 3.0 Level 2, IEC60870-5-104, IEC61850
Minimize communication down time - Reliable redundant
Ethernet Communication ports with 10/100BaseTX, 100BaseFX
with ST connectors, and optional double 100BaseFX, with
ST connectors Features (continued)
Complete asset monitoring - Full metering including demand Monitoring and Metering
& energy Energy metering
Follow technology evolution - Flash memory for product Demand metering
field upgrade Trip circuit monitoring
Oscillography
Applications Data logger
Sequence of event
F650: Management and primary protection of distribution Self diagnostic
feeders and bus couplers
F650: Backup protection of busses, transformers and User Interface
power lines Large graphic (16x40) or regular (4x20) character display
G650: Packaged generator mains failure detection Easy to use control via Shuttle key
G650: Distributed generation management device Front RS232
G650: Reliable Distributed Generation interconnection Rear wire 10/100BaseTX Ethernet for LAN connection.
protection system Rear wire CAN bus port (OPEN CAN protocol - W650)
W650: Wind turbine protection, control and monitoring Optional fibre optic 100BaseFX Ethernet, single or redundant.
W650: Distributed generation grid interconnection device Optional rear RS485 port
1 ready LED and 15 programmable LED indicators
EnerVista Integrator providing easy integration of data
Features in the 650 relay into new or existing monitoring and
Protection and Control control systems
Up to 32 Programmable digital inputs Energy metering
Up to 16 digital outputs Demand metering
Trip Circuit Supervision Trip circuit monitoring
Redundant power supply option Oscillography
Configurable PLC logic according to IEC 61131-3 Data logger
Fully configurable graphic display HMI interface Sequence of event
Alarms panel Self diagnostic

22-14 BuyLog Catalog www.gedigitalenergy.com Rev. 11/13


Data subject to change
without notice
Relays and Meters Section 22
Protection & Control
SR 3 Family
Intuitive industrial and utility protective relays systems
for feeders, motors and transformers

Key Benefits
Easy to use and cost effective protection and control for feeders,
motors and transformers
Effortless draw-out construction eliminates requirements for test
switches and reduces downtime
Environmental monitoring system to alarm on destructive
operating conditions and plan preventative maintenance
Easy to use interface and set up in one simple step
Accelerated Life Cycle Tested to ensure reliability of relay
operation under abnormal conditions
Advanced power system diagnostics to increase reliability
through fault and disturbance recording capabilities
Large backlit display with 40 characters for easy viewing of relay
information and settings
Flexible communications with multiple ports & protocols to allow
seamless integration into new and existing infrastructure
Easy access to information via multiple communication network
options including USB, Serial, Fiber & copper Ethernet
Reduced wiring with support for remote I/O
Reduce setup and configuration time with the Simplified Motor Features
Setup screen Monitoring and Metering
Powerful Security Audit Trail tool to increase security and Metering and Monitoring
minimize system risks by tracking setting changes Event Recorder: 256 events with 1ms time stamping
Oscillography with 32 samples per cycle and digital states
Applications
IRIG-B clock synchronization
350 Feeder Protection Relay health diagnostics
345 Transformer Protection Security audit trail
339 Motor Protection
User Interface and Programming
4X20 character LCD display
Control panel with 12 LED indicators
Front USB and rear serial, Ethernet and Fiber ports
Multiple protocols - IEC 61850 GOOSE, ModBus RTU, ModBus
TCP/IP, DNP 3.0, IEC60870-5-104, IEC60870-5-103, Profibus,
DeviceNet
EnerVista Software
Enervista Software- an industry-leading suite of software tools
that simplifies every aspect of working with Multilin devices.
Document and software archiving toolset to ensure reference
material and device utilities are up-to-date

Rev. 11/13 www.gedigitalenergy.com BuyLog Catalog 22-15


Data subject to change
without notice
Relays and Meters Section 22
Protection & Control
SR 3 Family
Intuitive industrial and utility protective relays systems
for feeders, motors and transformers
Overview Advanced Communications All relays utilize EnerVista setup software
Easy integration into new or for communication, monitoring and meter-
The SR 3 Series protection relays is a highly
existing infrastructure ing. Actual values, setpoints, status, trend-
functional economical protection relay for
ing, and waveform capture information
feeders, motors and transformers. By With several Ethernet and serial port op-
may all be viewed via the software, and can
providing an economical system for tions, and a variety of communication pro-
be used for troubleshooting.
protection, control, monitoring and tocols, the SR 3 Series provides advanced
metering, and both local and remote user and flexible communication selections for Security
interfaces in one assembly, the SR 3 Series new and existing applications. Security Audit Trail
relays effectively eliminate the need for The SR 3 Series supports various industry The SR 3 Series monitors security and
expensive discrete components. standard protocols such as, IEC 61850 reliability of asset protection. The SR 3
The SR 3 Series provides detailed diagnostic GOOSE, Modbus RTU, Modbus TCP/IP, Series protection devices offer complete
information allowing users to troubleshoot DNP3.0, IEC 60870-5-104 and IEC 60870-5- traceability of any relay setting and
and minimize downtime. Detailed diagnos- 103 providing simplified and easy integra- command changes allowing the user to
tics is provided via the 256 1mS time tion into new and existing applications. quickly identify changes made to the relay.
stamped event recorder and the 192 cycle Enhanced Diagnostics EnerVista Launchpad
Oscillography report sampled at 32 samples
Preventative Maintenance EnerVista Launchpad is a complete set of
per cycle.
powerful device setup and configuration
The SR 3 Series allows users to track relay
The robust SR 3 Series streamlines user tools that is included at no extra charge
exposure to extreme environmental condi-
work flow processes and simplifies with the SR Relays.
tions by monitoring and alarming at high
engineering tasks such as configuration, Set up the SR Relays - and any
temperatures. This data allows user to
wiring, testing, commissioning, and mainte- other Multilin device - in minutes.
proactively schedule regular maintenance
nance. This cost-effective relay also offers Retrieve and view oscillography and
work and upgrade activities.
enhanced features such as diagnostics, event data at the click of a button.
preventative maintenance, device health Build an instant archive on any of the
reports and advance security features. latest Multilin manuals, service advisories,
Easy to Use application notes, specifications or
firmware for your SR Relay.
Drawout Construction
Automatic document and software
The SR 3 Series offers a complete drawout
version updates via the Internet and
feature eliminating the need for rewiring
detailed e-mail notification of
after testing has been concluded. The with-
new releases.
drawable feature also eradicates the need
to disconnect communication cables, e.g.
fiber, copper, RJ45, etc and helps retain
communication status even after a relay
has been withdrawn from its case.

Dimensions
Overall dimensions on 350, 339 and 345 are identical. Terminal configurations vary and
are not shown.
5.350 +_0.010
(131.1 mm +_0.25mm)

4.100 +_0.010
(104.1 mm +_0.25mm)

CIL
o 0.200
(5.1 mm)

3.96
7.93 100.6mm 6.900 +_0.010
201.51mm (175.3 mm +_0.25mm)

6.000 +_0.010
CIL (152.4 mm +_0.25mm)
4.000 +_0.010
(101.6 mm +_0.25mm)

1.73 7.89
43.8mm 200.4mm
6.62
168.2mm

22-16 BuyLog Catalog www.gedigitalenergy.com Rev. 11/13


Data subject to change
without notice
Relays and Meters Section 22
Protection & Control
MII Family
Modular Microprocessor Family
An economical choice for standard digital relying applications

Key Benefits
Ease of use and installation - same front panel programming,
common cutout
Follow technology evolution - Flash memory for product field
upgrades
Low priced scalable options - event reports, waveform capture,
recloser, breaker fail
Reduce troubleshooting and maintenance cost - Event reports,
waveform capture
Design flexibility - Easy to use programming logic
Asset monitoring - Breaker health, and breaker failure protection
Access to information - Modbus RTU communications
AC/DC power supply
Easy access via front panel keypad or communication links

Applications
Feeder protection Features
Main protection for small generators and motors Features and Benefits
Backup/Auxiliary protection for transformers, motors, Digital relay
generators and busbars Incorporates protection, and control
Overload protection Local and remote user interfaces
Automatic transfer equipment Internal memory
Load shedding and restoration schemes Diagnostic features - event recording, and oscillography
Backup directional overcurrent protection User Interface and Programming
Reverse power protection Front Panel LEDs, key pad, and 2x16 character LCD display
Synchrocheck 6 LED indicators, 4 configurable in function and color
Front RS232 and rear RS485 ports using ModBus RTU protocol