                                                             TECHNICAL
                                                           INFORMATION
                                                           INSTALLATION
                                                                and
                                                              SERVICE
                                                          INSTRUCTIONS
Phone numbers:
                                                   LEAVE THESE INSTRUCTIONS
Installer ________________________                ADJACENT TO THE GAS METER
NOTE - Technical details involving gas compositions refer to standard gas only.
                              FERROLI NOUVELLE ELITE 100
It is law that all gas appliances are installed by competent persons, in accordance with the Regulations.
Failure to install appliances correctly could lead to prosecution.
It is in your own interest, and that of safety, ensure thet the law is complied with. Manufacturers instruction
must NOT be taken in any way as over-rideing statutory obligations.
NOTE - Technical details involving gas compositions refer to standard gas only.
2
              FERROLI NOUVELLE ELITE 100
 1  11   General
 1        Front page
 2        General informations on installation
 3        List of contents
 4        Technical data
 5        Phsycal dimensions
 6        Important components
 7        General description
 8        Boiler flow diagram
 9        Key to boiler flow diagram
10          D.H.W. performance
11          Pump performance curve and bypass C.H.
12  25   Installation
12        Minimum siting dimensions standard installation
13        Air supply - Flue system
14        Typical installation of pipework bypass and fitting
          additional expansion vessel
15        Jig assembly (optional)
16        Electric supply
17        Filling C.H. - Flushing C.H. - Descaling D.H.W.
18        General explanation on operation
19        Commisioning and general check out
20          Modulating regulator (Modureg) of gas valve
20          Adjustments and checkout gas valve Honeywell
21          Adjustments and checkout gas valve SIT
22        C.H. output adjustment
23        Burner pressures C.H.
24        Wiring diagram
25          Mounting details
26  33   Servicing
26         General fault finding - Cleaning and Maintenance
27         Faults finding causes and remedies
29         Spare parts list
                                                                3
                             FERROLI NOUVELLE ELITE 100
Technical data
                                       NATURAL GAS (G20)                   LPG        PROPANE (G31)
Nominal heat input (combined C.H. & D.H.W.)          25.8 kW           25.8 kW                25.8 kW
Nominal heat output (combined C.H. & D.H.W.)         23.3 kW           23.3 kW                23.3 kW
Minimum heat out. (combined C.H. & D.H.W.)             9.3 kW            9.3 kW                 9.3 kW
Gas rate (nominal)                                2.73 m3 S/h                  /            1.983 kg/h
Burner setting pressure                        13 mbar (max)      28 mbar (max)         36 mbar (max)
Minimum burner pressure                       2.5 mbar (min.)      7 mbar (min.)         8 mbar (min.)
Main injector                                       2.25 mm           1.20 mm                1.20 mm
Pilot injector                                      0.51 mm           0.25 mm                0.25 mm
Dimensions (o/all)
Height                                                800 mm
Width                                                 445 mm
Depth                                                 360 mm
Weight (net)                                             45 kg
Weight (gross)                                           47 kg
Flue duct: nominal size                               130 mm
Electric supply:                                230 V 50 - Hz
Fuse rating:
Mains                                      3 Amp. (main fuse)
on P.C.B. in boiler                              1 Amp. Fast
Power requirement                                  160 Watts
Domestic hot water flow:
(25  30 C rise)                                1311 l/min.
Safety valve pressure setting                           3 bars
Minimum incoming mains flow                         2.5 l/min.
Maximum domestic cold water
Inlet pressure:                                       5.0 bars
Expansion vessel capacity                              7 litres
Min. heating circuit pressure                         0.8 bars
Max. heating circuit pressure                         3.0 bars
Boiler water capacity:
Heating                                              1.5 litres
Domestic hot water                                   0.5 litres
Pipe connections:
Gas                                               3/4 in. BSP
Domestic cold water inlet                         1/2 in. BSP
Domestic hot water outlet                         1/2 in. BSP
Central heating flow                              3/4 in. BSP
Central heating return                            3/4 in. BSP
Pressure relief valve drain                       1/2 in. BSP
Min. installation clearances. Sides:
Left hand                                              20 mm
Right hand                                             20 mm
Front                                                  50 mm
                                     (plus access for service)      NOTE - LPG is a mixture of Propane
and
Min height from worktop to base                       300 mm        Butane.
4
              FERROLI NOUVELLE ELITE 100
                                                                                                        min.
                                                                                                  500
Key
      1.    Electricity cable entry
      2.    Gas supply
      3.    Domestic hot water outlet
      4.    Domestic cold water inlet
      5.    Central heating pressure relief valve
      6.    Central heating flow outlet                                                  Fig. 4
      7.    Central heating return inlet
Note - Without C.H. expansion vessel, the pipework can pass up the back of the boiler.
                                                                                                               5
                                FERROLI NOUVELLE ELITE 100
Important components
Fig. 2
Fig. 1
Fig. 3
6
              FERROLI NOUVELLE ELITE 100
General description
The Nouvelle Elite 100 is wall mounted, natural draught, combination boiler for central heating and domestic
hot water. The boiler is of light weight construction and the unit provides central heating and domestic hot
water from an integrally designed double heat exchanger. The appliance is suitable for sealed systems only,
and is not suitable for external installation. An expansion vessel is incorporated. The wall mounting jig
contains connections for the water and gas supplies. This can be fitted to the wall and provides all the
necessary gas and water connections prior to the boiler being attached.
Important details
22 Stainless Steel gas burner for the complete and safe combustion of Natural Gas (and on request L.P.G.).
32 Central heating pump with 3 speed switch, perfectly adaptable to the nature of the central heating
   system. This avoids necessary electrical power consumption and noise problems.
   The pump is switched ON/OFF by the time clock (if fitted) and/or a 24 Volt room thermostat.
   The pump circuit also has a 6 minute over/run time.
40 Filling cock for to fill the central heating system from Domestic Cold Water net.
44 Combination gas valve, providing on/off and modulating control of the gas burner.
68 Control box with printed circuit board (P.C.B.). The central heating and the domestic hot water
   temperature is controlled by the Honeywell Modureg gas valve (44) in conjunction with the P.C.B. and
   the two sensor for C.H. (34) and D.H.W. (42). The C.H. temperature can be set with the C.H. boiler stat
   (63). The D.H.W. temperature is factory set on the P.C.B. There is a limit thermostat (50) on the central
   heating circuit which operates at 85 C. There is also on overheat cut/off thermostat (49) which will shut
   the boiler and pilot down completely at 100 C. On the P.C.B. the maximum output for central heating
   can be set. This does not influence the maximum output for domestic hot water!
73 Frost thermostat to protect the boiler in winter conditions. This thermostat activates the boiler as soon
   as the heat exchanger temperature is too low, regardless of position of the controls (optional).
75 Copper heat exchanger for C.H. and D.H.W. The central heating water and domestic water are heated
   up directly by the gas flame (in separatd circuits of course).
   This system provides quick response (instantaneous), avoids heat losses and makes heating and
   domestic hot water completely independant.
126 Flue gas safety thermostat which switches off the burner (pilot included) in case of flue losses under the
    draft diverter (f.e. chimney blocked).
136 There is a domestic flowmeter fitted and when there is a demand for domestic hot water (flow of more
    than 0,5 gallon/minute, 2.5 litres/minute) the central heating pump is switched off, making available the
    maximum output of the gas burner for domestic hot water.
                                                                                                            7
    FERROLI NOUVELLE ELITE 100
8
            FERROLI NOUVELLE ELITE 100
                                                                                              9
                               FERROLI NOUVELLE ELITE 100
Fig. 1
Fig. 2
10
               FERROLI NOUVELLE ELITE 100
Fig. 1
NOTES:
Additional expansion vessel (if required), must be fitted to Central Heating
Return Inlet (fig. 2).
A bypass as far as possible from boiler is necessary if all radiators have
Thermostatic Radiator Valves (fig. 2).
Check automatic air vent (fig. 3).
Always chack if shaft of pump is not locked.
Set C.H. pressure to minimum of 1,0 bar (by preference to 1,5 bar).
Use the filling cock (fig. 3).
                                                                    40
                                                              Filling Cock
                                                                14 C.H.
                                                              safety valve
Fig. 2 Fig. 3
                                                                                                         11
                               FERROLI NOUVELLE ELITE 100
Installation Details
Minimum clearances
If the boiler is installed (for example) in hair dressers premises, ventilation must not be from areas which
aerosol hair spray is being used. Any spray or materials emitting volatile vapours can be a sourge of ignition
from the permanent pilot of the boiler. Propellants of aerosol sprays and fumes of volatile compounds in
addition to being highly flammable in many cases, will also change to corrosive hydrochloric acid when
expose to the products of combustion of the boiler. The results may be hazardous, cause service problems,
product failure and corrosion problems.
12
                FERROLI NOUVELLE ELITE 100
Air supply
The following notes are intended to give guidance only.
Room or internal air space supply:
The Nouvelle Elite 100 requires a permanent air vent for combustion air either from the room direct
to outside air or to an adjacente room which must itself have a permanent air vent of the same size, direct
to outside air. The minimum size of this air vent must be: 94 cm2 free a (14 in2). A proprietry air vent may be
murked with its effective free area, if not, this information can usually be supplied by the maker. The vent
should be designed to diffuse the air in windy conditions and should be sited to reduce room draughts, i.e.
at top level. The aperture in the vent should not pass preferably, a 10 mm (3/8 in.) ball but allow the entry
of a 5 mm (3/16 in.) ball. (Additional gauzes or screens should not be used). Existing air vents should be
taken into account when accessing air vent requirements. An air vent in an internal wall should not
communicate with a bedroom, toilet, bathroom or kitchen and should not be more than 450 mm (18 in.) above
floor level in order to reduce the spread of smoke in the event of a fire. An air vent direct to outside air must
not be located less than 600 mm (2 ft.) away from any part of an open flued terminal nor less than 300 mm
(12 in.) directly above any part of a balanced flue terminal.
Note - Bot air vents must communicate whit the same room or must be on the same outside all to outside
air. Where cupboard/compartment air vents are open to a room, the room itself must have a permanent air
vent(s) as previously specified.
Flue system
The following notes are intended for general guidance. The cross sectional area of flue serving the boiler
must not be less than the area of the flue outlet of the appliance. The boiler has a flue spigot designed
for aluminium or stainless steel flue pipe. If double walled flue pipe is used, it should be of a suitable type.
Always use a split flue clip or flanged joint above the flue diverter to allow the removal of the boiler. A vertically
rising flue above the diverter for a minimum length of 600 mm (2 ft.) is required before any bend is fitted,
which should not be a 90 pattern. The flue pipe must be adequately supported and not be contact whit any
inflammable material. If any existing chimney is to be used, it should be lined with a stainless steel flexible
liner. The number of metal flue liner joints should be kept to the minimum for connecting the boiler to
an existing flue, the flue must be clean of any soot or loose material. Dampers must be removed. The flue
should be, as far as is practical, vertically rising with the avoidance of horizontal runs. The metal flue
pipe listed above should form the initial connection from the boiler to the existing chimney (and liner).
If the boiler is installed (for example) in hair dressers premises, ventilation must not be from areas which
aerosol hair spray is being used. Any spray or materials emitting volatile vapours can be a sourge of ignition
from the permanent pilot of the boiler. Propellants of aerosol sprays and fumes of volatile compounds in
addition to being highly flammable in many cases, will also change to corrosive hydrochloric acid when
expose to the products of combustion of the boiler. The results may be hazardous, cause service problems,
product failure and corrosion problems.
                                                                                                                   13
                                    FERROLI NOUVELLE ELITE 100
Typical Installation of Pipe Work, Bypass and fitting additional expansion vessel C.H.
Gas
                              Cold water
                                                                                 Additional expansion vessel
Bypass
Fig. 1
Important - Fit bypass as far as possible from boiler if thermostat radiator valves are fitted.
14
               FERROLI NOUVELLE ELITE 100
Important Note - Always use two spanners to prevent twisting of soft copper pipework.
                                                                BOILER AFTER
                                                                INSTALLATION
2 = Gas 3/4"                        3 = Domestic Hot          5 = Outlet Central Heating   6 - 7 = Central Heating Flow
    Note - Rubber seal on Gas!          Water outlet 1/2"         safety valve 1/2"                and return 3/4"
Important Note - To connect the boiler to service cocks or to the pipeworks, always use two spanners to
prevent twisting of soft copper pipework.
Note 1 - Without expansion vessel, the pipework can pass up the back of the boiler. C.H. expansion vessel
can be fitted elsewhere in the system.
Note 2 - The central heating safety valve should be piped to discharge safety outside the property.
                                                                                                                   15
                               FERROLI NOUVELLE ELITE 100
Electrical installation must be carried out by a competent electrician. The appliance is to be connected
to a 230/240V ~ 50 Hz supply. The supply fuse rating is 3A. The terminals are accessible after removing the
white base plate and single screw securing the terminal cover.
         External controls:
         room stat or remote
         time clock in the place
         of loop terminals 4 and
         5. Please note 24 V only.
Procedure
The supply cable must be not be no less than 0.75 mm (24 x 0.2 mm) to BS6500 table 16.
The earth conductor must be cut longer than the live and neutral.
Connect the Supply Cable to the terminal block marked 230/240 V ~ 50 Hz, L, N, the supply cable is to be
connected as follows:
 Connect the brown wire to the L (live) terminal.
 The blue wire to the N (neutral) terminal.
 The green/yellow wire to the (earth) terminal.
16
                 FERROLI NOUVELLE ELITE 100
Very important - When flushing the Domestic Hot Water part of the boiler with cleansing agent, the Flow
Switch Assembly 37 - 136 - 39 must be removed.
Guarantee on the flow switch assembly 37 - 38 - 39 is void, if flushed with any cleansing agent!
                                 136
                 39
       37
                                                    37 Cold water inlet filter
                                                    136Flowmeter
                                                    39 Cold water flow restricter
General:
1.   C.H. system should be filled with the filling cock 40 very slowly with water and prevent that air is filled within.
2.   Vent radiators of C.H. regular.
3.   Heat Exchanger can be vented with heat exchanger venting point 53 (do not unscrew completely).
4.   Leave loose the cap of automatic air vent 36. So air can pass!
5.   Do not use the central heating safety valve 14 as a drain point.
6.   It is advisable to flush and refil the C.H. system one day after the complete system has functioned at max.
     temperature.
                                                                                                                     17
                              FERROLI NOUVELLE ELITE 100
3.0   Selector switch 61 in third position (Domestic Hot Water and Central Heating):
3.1   Hot water taps closed
3.1.1 Room stat demands for heat:
       Central heating pump will rung continuously
       Boiler thermostat 63 controls the boiler temperature in a modulating way
       Time Clock 62 if fitted influence the boiler fonctionnement.
3.1.2 If contact in Room stat breaks (Room temperature too high):
       Burner stops immediately
       Central Heating pump stops after about 5 minutes (pump overrun)
3.2   Hot water tap open (water flow min. 0,5 Gallon/min. 2,5 Litres/min.).
       Central heating pump stops immediately (priority to domestic hot water)
       Burner is controlled to keep the hot water at a internally factory set temperature of 50C.
18
                  FERROLI NOUVELLE ELITE 100
                                                                                                                              19
                                FERROLI NOUVELLE ELITE 100
                                                                                 Pilot gas supply pipe
Key
1. Cap
2. Shaft
3. Adjustment screw for maximum pressure setting             60 Extension knob
4. Adjustment screw for maximum pressure setting
5. 6,3 mm AMP terminals                                                                   Gas inlet union
20
             FERROLI NOUVELLE ELITE 100
Modureg
Important: for the gas valve SIT first the maximum pressure should be set and the minimum pressure.
                                                                                                      21
                                FERROLI NOUVELLE ELITE 100
                                                                                                                             X7                                   X6
                                                                                                      X3
                                                                                                                                                                   2AT
F1
P1 P2 RY1
RY2
                                                                                                 X8
                                                                                                                             TR1
MAX
MIN
                                                                                                                                                                  MAX
45 - Knob gas valve
46 - Operator gas valve
                                                                                 P1                                                       P2
47 - Modulating regulator (Modureg)
48 - Burner pressure test point                                                          Fig. 3 - Potentiometres settings
66 - Microswitch
Operations
1. Check if all hot water taps are closed.
2. Disconnect ONE electrical connection from operator 46 of gas valve 44.
Note - Don't pull the wire, use pliers and pull the faston insulation to the front.
22
               FERROLI NOUVELLE ELITE 100
35
30
mbar 20
15
10
                                             kW     9            10 11 12 13 14 15 16 17 18 19 20 21 22 23
                                             kcal/h                 9     10       11       12       13    14    15    16    17   18     19    20
                                             X 1000
                                                         15
Fig. 5 - Burner pressure VS C.H. load with               14
natural gas (G20)
                                                         13
12
11
10
                                                          8
                                              mbar
                                                          2
                                                                      7    8        9       10 11          12 13      14 15 16         17 18    19   20   21 22     23 24
                                                               kW
                                                               kcal/h 6        7        8        9        10    11    12    13    14    15     16    17   18   19   20   21
                                                               x 1000
NOTE - For gases not mentioned please ask for details to FERROLI
technical Dpt.
                                                                                                                                                                            23
                                                    FERROLI NOUVELLE ELITE 100
Wiring diagram
  49
                         24 V                                        220V ~ 50 Hz.
126
25
                                                                                          2    1
 23                                                                                        F   N    67
       42     34   47                                         46
                        114 50
                                           136                                                 66
                                       -   OUT +
                                                                                                                          61
                                                                        2 1                                          1
                                                                                                                              a    80
                                                                                                                                        L
  X1                                              X2    X4
                                                                                                                    2          b             220V
       12 11 10 9 8 7 6 5 4 3          4 3 2 1               6 5 4                                                                      N
                    13 121110 9 8 7 6 5 4 3 2 1
                                                   X3                   3   2 1
                                                                   X6                               32
                                  63       157
                                                                                                                    3         c              4
                                                                                                                                                    24V
                                                                                                                                             5
                                                                                                                                        80
                                                                                                                               d                    72
                                                                                                                     4
                                 X8                             MF7
                                                                                                                         73
remove if time clock is fitted o o o o to connect if time clock or frost thermostat are fitted
Key
23. Thermocouple                                                       63.    C.H. boiler thermostat
24. Spark electrode                                                    66.    Microswitch combination gas valve
32. Central heating pump                                               67.    Ignition transformer
34. C.H. flow temperature sensor                                       72.    Room thermostat (not fitted)
42. D.H.W. temperature sensor                                          73.    Frost thermostat predisposition
46. Operator gas valve                                                 80.    Five pole terminal block (230/240 V - 24 V)
47. Modulating regulator (Modureg) gas valve                          114.    Water flow switch
49. Overheat cut-off thermostat 100 C                                126.    Flue gas safety thermostat
50. Heat exchanger limit thermostat 85 C                             136.    Flowmeter
61. C.H./D.H.W. selector switch                                       157.    D.H.W. boiler thermostat
Warning - Any external voltage (230 V or low voltage) applied to the block 1-2 of the terminal block 80 or internal wiring
of the boiler, will damage the P.C.B. in the control box.
24
                FERROLI NOUVELLE ELITE 100
Mounting Details
Thermostat - Pilot - Gas Valve
                                                                          Fig. 2
                  Fig. 1
                                                  Pilot assembly (for replacement: unscrew central
50. Heat exchanger limit thermostat               screw and pull pilot assembly to bottom)
                                                  22. Burner
                                                  23. Thermocouple
                                                  24. Spark electrode (for replacement: pull to bottom)
73. Frost thermostat (if fitted)                  25. Pilot
Fixing screws
                                                                                                    25
                                FERROLI NOUVELLE ELITE 100
To the User/Installer
Important - See also page Filling C.H. - Flushing C.H. - Descaling D.H.W.
Never pull on the wires in the Fastons. To disconnect the Fastons pull on the insolation of the Fastons with
pliers, keep the terminal pushed back with a screwdriver.
It is advised to submit the system and least once a year to the following controls.
The system water pressure when hat in operation has to be between 1 and 1.5 bar if not it has to be brought
inside the required level. The boiler safety and requlating controls have to work properly.
The burner and the copper heat exchanger have to be cleaned by mean of soft brushes, do not use
cheminal products. The expansion tank has to be under pressure.
The gas and water circuits have to be tightened. The chimney and the boiler flue have to be free of any
obstruction and without any leaking. The thermocouple has not to present deposits on it and has to be
envelopped correctly by the pilot flame. The gas flow pressure has to be in accordance to the technical data.
The circulating pump has to run freely.
26
             FERROLI NOUVELLE ELITE 100
Bursting at the main                         Pilot flame too distant from main burner
                                             Place the pilot flame closer to the main burner
                                             Dirty heat exchanger
                                             Clean the heat exchanger
                                             Gas flow to low
                                             Set correct gas pressure at the main burner
                                             Dirty burners
                                             Clean burners
                                                                                                    27
                            FERROLI NOUVELLE ELITE 100
Boiler function but temperature does not increase     Wrong burne flame
                                                Ceck gas consumption
                                                Dirty heat exchanger boiler output to low
                                                Ceck heat requirement
                                                Thermostat probe not properly located in its pocket
                                                Place the probe properly in the pocket
                                                Wrong setting of the requlating thermostat
                                                See chapter controls adjustment
Domestic hot water temperature not constant       Hot water flow to low
                                                  Increase flow to a minimum of 2.5 l/min
28
             FERROLI NOUVELLE ELITE 100
                                                                          29
                                  FERROLI NOUVELLE ELITE 100
Phone numbers:
Installer _________________________
32