PROJECT NAME : PROPOSED BPO & OFFICE BUILDING
BUILDING DATA
Floor GLA Passenger Passenger PE/SE/Fireman's
Floor Name Floor Usage GFA (sqm) PE /SE (BPO) Population
Height(mm) (sqm) Elevator (BPO) Elevator (Office) Lift (Office)
Machine Room 3,500 Machine Room M/R M/R x
RD 3,500 Roof Deck OH OH x
24 4,000 Executive Office 891.18 614.98 67
23 4,000 Executive Office 891.18 614.98 O O 67
22 4,000 Executive Office 891.18 614.98 O O 67
21 4,000 Executive Office 891.18 614.98 O O 67
20 4,000 Executive Office 891.18 614.98 O O 67
19 4,000 Executive Office 891.18 614.98 O O 67
18 4,000 Executive Office 891.18 614.98 O O 67
17 4,000 Executive Office 891.18 614.98 O O 67
16 4,000 Enterprise 1119.67 945.87 O O 102
15 4,000 Enterprise 1119.67 945.87 O O 102
14 4,000 Enterprise 1119.67 945.87 M/R M/R O O 102
12 4,000 BPO 2141.65 1933.63 / OH / OH n/s O 387
11 4,000 BPO 2141.65 1933.63 O O n/s O 387
10 4,000 BPO 2141.65 1933.63 O O n/s O 387
9 4,000 BPO 2141.65 1933.63 O O n/s O 387
8 4,000 BPO 2141.65 1933.63 O O n/s O 387
7 4,800 Parking O O O O x
6 3,200 Parking O O O O x
5 3,200 Parking O O O O x
4 3,200 Parking O O O O x
3 3,200 Parking O O O O x
2 5,000 Main Lobby BPO / Retail 405.42 405.42 O n/s O 73
G 6,000 Main Lobby Exec Ofc./ Retail 1084.55 1084.55 388
Total 22,686.67 ###
Total Population (persons) 3238
Total Travel (m) 42.6 42.6 67.6 92.6
Legend:
O - Intermediate Service Floors Other Req'd Criteria:
- Top Terminal Floor -8 car elevator
- Bottom Terminal Floor -5 minute handling capacity = 10% to 11% of Total Population
n/s- Non Service Floor
OH - Overhead
M/R - Machine Room