Liquid Level Switches: MLS Series

The document describes Murphy MLS Series liquid level switches which use a float to activate an electrical switch for level indication. The switches connect directly into scrubbers and include features like clean magnet design, seal-free construction, and ability to operate in fluids with 0.5 SG or higher. They are rated for 2000 PSI and -20 to 300°F.

Uploaded by

fharishputra
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
304 views2 pages

Liquid Level Switches: MLS Series

The document describes Murphy MLS Series liquid level switches which use a float to activate an electrical switch for level indication. The switches connect directly into scrubbers and include features like clean magnet design, seal-free construction, and ability to operate in fluids with 0.5 SG or higher. They are rated for 2000 PSI and -20 to 300°F.

Uploaded by

fharishputra
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

sect.

15 1010629
rev. 2014/10/25

Liquid Level Switches


MLS Series
MLS Series Liquid Level Switches are float activated to
operate an electrical SPDT reed switch for annunciation/
pilot signal for indication of high level to an annunciator,
controller or PLC. The MLS connects directly into the
gas scrubber wall and can be used with a Murphy weld
collar or Murphy external float chamber. The MLS Series
is available in both 1 1/2 and 2 in. NPT models.
Features of the MLS Series includes:
• Clean magnet design virtually eliminates iron filing
accumulation on the magnet Specifications
• Seal-free construction
• ANSI/ISA 12.27.01 compliant (Single Seal) Process Connection: 2” NPT (MLS-020); 1-1/2” NPT (MLS-015)
• Operates in 0.50 specific gravity or heavier fluids Fluid Density (SG):
• Designed for harsh gas compressor scrubber 0.50 MIN (no extension)
applications 0.65 MIN (1 inch extension)
• 304 cast equivalent SS body and 304 SS float Pressure Rating: 2000 psig (13.8 MPa) [138 bar]
• Rated for 2000 psi (13.8 MPa) [138 bar] working Body: ASTM A351 CF8 (304 SS)
pressure Cover: ASTM A351 CF8 (304 SS)
Other Wetted Parts: 303, 304 and 316 SS
• Trip on rising and falling without need to rotate body
Process Temperature: -20° to 300° F (-29° to 149° C)
• Electric model only available Electrical: 30VAC/VDC 75mA Form C SPDT
• All models screw directly into the scrubber or can be Conductor cross section AWG/kcmil min.: 26
mounted via a Murphy External Float Chamber Conductor cross section AWG/kcmil max.: 16
• CSA C/US Class I, Div. 1, Grp. B, C & D locations Canadian Registration Number: 0F12013.2 C (all provinces and
• Canadian registered territories)

Dimensions

In order to consistently bring you the highest quality, full-featured products, we reserve the right to change our specifications and designs at any time. MURPHY products and the Murphy
logo are registered and/or common law trademarks of Enovation Controls, LLC. This document, including textual matter and illustrations, is copyright protected by Enovation Controls, LLC,
with all rights reserved. (c) 2015 Enovation Controls, LLC. A copy of the warranty may be viewed or printed by going to http://fwmurphy.com/warranty.
Electrical Wiring

How to Order

Part Number Description Notes


15700840 MLS-015 1-1/2 in. NPT
15700839 MLS-020 2 in. NPT
15700799 External Float Chamber Operating Pressure: 2000psi (13.8MPa) [138 bar]
15050375 Weld Collar Operating Temperature: 400°F (204°C)
15000892 1-inch Float Extension Kit

Approximate Shipping Weight: Approximate Shipping Dimensions:


MLS-015: 5 lbs. (2.27 kg) MLS-015 and MLS-020: 14 x 5 x 3.5 in. (356 x 127 x 89 mm)
MLS-020: 5.5 lbs. (2.49 kg)
External Float Chamber: 18 lbs. (8.2 kg)
Weld Collar: 6 lbs. (2.7 kg)

Refer to MLS installation and operation manuals for additional information.