AIR/AIR HEAT PUMP SYSTEM NIBE™ ARIA
A unique opportunity for houses with direct electrical heating
NEW Features of NIBE™ ARIA
Unique design
Condensation lead off (accessory)
Indoor temperature adjustable down to +10
Remote control via App
Heating operation optimized down to –20 °C
Adaptive defrosting procedure
Advanced active air cleaning
Up to 60% lower heating costs
Complete air/air heat pump system
NIBE ARIA is a complete modern heat pump system that
offers efficient technical energy saving and reduced carbon
dioxide emissions. The integrated control system in the in-
door module gives safe and economical climate control.
The heat is retrieved from the outdoor air through an out-
door module (AG-AA10), where the refrigerant, which cir-
culates in a closed system, transfers the heat from the heat
source (outdoor air) to the indoor module (AG-WT/ WL).
ptimal annual coefficient of performance thanks to the
O
inverter controlled compressor.
A ++
Energy efficiency class
package label for NIBE
ARIA, Cooling +35°C
NIBE™ ARIA
Technical data and range
NIBE ARIA outdoor unit
Product type AG-AA10-30 AG-AA10-40 AG-AA10-50
Cooling +35°C SEER/energy class 6.1 / A++ 6.1/ A++ 6.7/ A++
Heating –10° SCOP/energy class 3.8 / A 4.0 / A+ 4.2 / A+
Heating output kW 0.9–3.9 0.9–4.9 1.0–5.3
Cooling output kW 1.4–3.7 1.0–4.1 0.9–5.7
Working range heating °C –20 – +43 –20 – +43 –20 – +43
Defrosting Reversible Reversible Reversible
Operating voltage 230 V 50 Hz 230 V 50 Hz 230 V 50 Hz
Type of refrigerant R410A R410A R410A
Volume kg 0.81 1.1 1.3
Sound pressure (max) dB(A) 40 44 41
Height, width, depth mm 700 x 265 x 540 895 x 345 x 630 895 x 345 x 630
Weight complete unit kg 35 56.4 56.4
NIBE ARIA indoor unit
Product type AG-WT10-4 AG-WT10-7 AG-WL10-4 AG-WL10-7
Air flow indoor unit (el.-l.-m.-h.) m3/h 330-460-540-660 520-610-720-800 450-500-590-700 615-665-760-830
Dehumidification l/h 1.5 2.0 1.3 2.3
Fan speed N° Auto + 3 speeds Auto + 3 speeds Auto + 3 speeds Auto + 3 speeds
Sound level indoor unit (el.-l.-m.-h.) dB(A) 25/31/39/42 36/39/42/46 22/26/30/37 28/30/37/45
Operating voltage 230 V 50 Hz 230 V 50 Hz 230 V 50 Hz 230 V 50 Hz
Plasma ion Plasma ion
Filter Nano technology Nano technology
technology technology
Weight kg 10 13.5 18 18
Dimensions (Height, width, depth) mm 289 x 845 x 209 300 x 970 x 224 600 x 750 x 220 600 x 750 x 220
NIBE Energy Systems
639663 NBD GB NIBE ARIA Single 1602-3 Box 14, SE-285 21 Markaryd
NIBE makes reservations for any factual or www.nibe.eu
printing errors in this brochure. ©NIBE 2016.