TF 000102

This document appears to be an engineering drawing containing details for a revolve cutter sharpness test fixture. It includes a parts list identifying 7 components of the fixture by item number, part number, and description. Dimensioning and tolerancing standards are specified according to ASME Y14.5-2009. The drawing is proprietary and confidential information for Devicor Medical Products Inc.

Uploaded by

api-299556237
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
3K views8 pages

TF 000102

This document appears to be an engineering drawing containing details for a revolve cutter sharpness test fixture. It includes a parts list identifying 7 components of the fixture by item number, part number, and description. Dimensioning and tolerancing standards are specified according to ASME Y14.5-2009. The drawing is proprietary and confidential information for Devicor Medical Products Inc.

Uploaded by

api-299556237
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 8

PCO Number: ECN Number: Release Date: Effective Date:

8 7 6 5 4 3 2 1

D D

C C

B B

A A

REVOLVE CUTTER
TITLE:

SHARPNESS FTP TEST


PROPRIETARY
AND
CONFIDENTIAL
INTERPRET GEOMETRIC
TOLERANCING PER:
ASME Y14.5-2009
FIXTURE
THE INFORMATION CONTAINED UNLESS OTHERWISE SPECIFIED:
IN THIS DRAWING IS THE SOLE
MATERIAL: SIZE DWG. NO.

B
PROPERTY OF DEVICOR DIMENSIONS ARE IN INCHES
MEDICAL PRODUCTS INC. TOLERANCES:
ANY REPRODUCTION IN PART
OR AS A WHOLE WITHOUT THE
WRITTEN PERMISSION OF
ANGULAR: 1/2°
TWO PLACE DECIMAL
THREE PLACE DECIMAL
.01
.005
SEE NOTES TF-000102
DEVICOR MEDICAL PRODUCTS FOUR PLACE DECIMAL .0005 DRAWN BY: DATE:
INC., IS PROHIBITED. ERIK KLOSE 09/01/2017 SCALE: 4:5 SHEET 1 OF 8

8 7 6 5 4 3 2 1
Lifecycle: Lifecycle State: Drawing Revision:
PCO Number: ECN Number: Release Date: Effective Date:
8 7 6 5 4 3 2 1

4
D
4 D

1
C C

2
6

ITEM NO. PART NUMBER DESCRIPTION QTY.


B
1 TF-000102-001 REVOLVE CUTTER SHARPNESS FTP 1 B
TEST FIXTURE
3 2 CA-000013-001 ASSEMBLY, CUTTER, ST PROBE, 8 GA, 1
9 cm
3 TF-000102-002 CUTTER RESTRAINT 1
7 COOL MUSCLE INTEGRATED
4 CM1-C-17L30C-SPD SERVOMOTOR, CM1 SERIES 2

SERVOMOTOR PRECISION FLEXIBLE


5 2764K214 SHAFT COUPLING FOR 3/6" X 3/16" 1
DIAMETER, 1-9/32" OVERALL
LENGTH, 1-1/64" OD
6 TF-000102-003 SERVOMOTOR GEAR 1

A 7 TF-000102-004 CUTTER GEAR 1 A

REVOLVE CUTTER
TITLE:

SHARPNESS FTP TEST


PROPRIETARY
AND
CONFIDENTIAL
INTERPRET GEOMETRIC
TOLERANCING PER:
ASME Y14.5-2009
FIXTURE
THE INFORMATION CONTAINED UNLESS OTHERWISE SPECIFIED:
IN THIS DRAWING IS THE SOLE
MATERIAL: SIZE DWG. NO.

B
PROPERTY OF DEVICOR DIMENSIONS ARE IN INCHES
MEDICAL PRODUCTS INC. TOLERANCES:
ANY REPRODUCTION IN PART
OR AS A WHOLE WITHOUT THE
WRITTEN PERMISSION OF
ANGULAR: 1/2°
TWO PLACE DECIMAL
THREE PLACE DECIMAL
.01
.005
SEE NOTES TF-000102
DEVICOR MEDICAL PRODUCTS FOUR PLACE DECIMAL .0005 DRAWN BY: DATE:
INC., IS PROHIBITED. ERIK KLOSE 09/01/2017 SCALE: 3:5 SHEET 2 OF 8

8 7 6 5 4 3 2 1
Lifecycle: Lifecycle State: Drawing Revision:
PCO Number: ECN Number: Release Date: Effective Date:
8 7 6 5 4 3 2 1

D
6 3 D
B

SECTION A-A
DETAIL B
SCALE 1.5 : 1

4 4

C C

2
A A
ITEM NO. PART NUMBER DESCRIPTION QTY.
B
1 TF-000102-001 REVOLVE CUTTER SHARPNESS FTP 1 B
TEST FIXTURE

2 CA-000013-001 ASSEMBLY, CUTTER, ST PROBE, 8 GA, 1


9 cm
3 TF-000102-002 CUTTER RESTRAINT 1

4 CM1-C-17L30C-SPD COOL MUSCLE INTEGRATED 2


SERVOMOTOR, CM1 SERIES
SERVOMOTOR PRECISION FLEXIBLE
5 2764K214 SHAFT COUPLING FOR 3/6" X 3/16" 1
DIAMETER, 1-9/32" OVERALL
LENGTH, 1-1/64" OD
6 TF-000102-003 SERVOMOTOR GEAR 1

A 7 TF-000102-004 CUTTER GEAR 1 A

REVOLVE CUTTER
TITLE:

SHARPNESS FTP TEST


PROPRIETARY
AND
CONFIDENTIAL
INTERPRET GEOMETRIC
TOLERANCING PER:
ASME Y14.5-2009
FIXTURE
THE INFORMATION CONTAINED UNLESS OTHERWISE SPECIFIED:
IN THIS DRAWING IS THE SOLE
MATERIAL: SIZE DWG. NO.

B
PROPERTY OF DEVICOR DIMENSIONS ARE IN INCHES
MEDICAL PRODUCTS INC. TOLERANCES:
ANY REPRODUCTION IN PART
OR AS A WHOLE WITHOUT THE
WRITTEN PERMISSION OF
ANGULAR: 1/2°
TWO PLACE DECIMAL
THREE PLACE DECIMAL
.01
.005
SEE NOTES TF-000102
DEVICOR MEDICAL PRODUCTS FOUR PLACE DECIMAL .0005 DRAWN BY: DATE:
INC., IS PROHIBITED. ERIK KLOSE 09/01/2017 SCALE: 1:2 SHEET 3 OF 8

8 7 6 5 4 3 2 1
Lifecycle: Lifecycle State: Drawing Revision:
PCO Number: ECN Number: Release Date: Effective Date:
8 7 6 5 4 3 2 1

D D

C C

B B

A A

REVOLVE CUTTER
TITLE:

SHARPNESS FTP TEST


PROPRIETARY
AND
CONFIDENTIAL
INTERPRET GEOMETRIC
TOLERANCING PER:
ASME Y14.5-2009
FIXTURE
THE INFORMATION CONTAINED UNLESS OTHERWISE SPECIFIED:
IN THIS DRAWING IS THE SOLE
MATERIAL: SIZE DWG. NO.

B
PROPERTY OF DEVICOR DIMENSIONS ARE IN INCHES
MEDICAL PRODUCTS INC. TOLERANCES:
ANY REPRODUCTION IN PART
OR AS A WHOLE WITHOUT THE
WRITTEN PERMISSION OF
ANGULAR: 1/2°
TWO PLACE DECIMAL
THREE PLACE DECIMAL
.01
.005
SEE NOTES TF-000102-001
DEVICOR MEDICAL PRODUCTS FOUR PLACE DECIMAL .0005 DRAWN BY: DATE:
INC., IS PROHIBITED. ERIK KLOSE 09/01/2017 SCALE: 1:1 SHEET 4 OF 8

8 7 6 5 4 3 2 1
Lifecycle: Lifecycle State: Drawing Revision:
PCO Number: ECN Number: Release Date: Effective Date:
8 7 6 5 4 3 2 1

.826 .826 .198 .198


2X R.031
E E 4X R.063 .374
.216 .216 .216 .216 .156
.141
.174 R.125 D .078
.216 8X R.250
.531
D .313 D
8X R.250 D
R.085 SECTION C-C 4X R.063
.823 SECTION D-D
.826 8X .150 .094 .636
THRU ALL 1.653 .636
1.646
1.653
.900
2X 1.125 .425
THRU ALL .425
.188
.216 4X R.250 SECTION E-E
.174 1.653 1.653 .388
G
4X R.125
1.250 .588
C
.325 1.225 C
.588
1.250
.338 .313

.925
SECTION H-H 4X R.125
.063
.174 .174 .175
1.650 F

1.875 1.625
.222
1.250
.125
B B

1.000 1.538 1.000 H 1.750 H


1.316
.8
.316
.188 1.750
SECTION F-F
F SECTION G-G
.313
1.375
2.625
2.969 NOTE:
1. THE HOLES SHOWN IN SECTION H-H ARE TO THE
SAME DEPTH AS THE CHANNEL SHOWN IN SECTION
A
G-G (1.750") A

REVOLVE CUTTER
TITLE:
.325 2.0°
R.125 SHARPNESS FTP TEST
.625 PROPRIETARY
AND
CONFIDENTIAL
INTERPRET GEOMETRIC
TOLERANCING PER:
ASME Y14.5-2009
FIXTURE
R.250 THE INFORMATION CONTAINED
IN THIS DRAWING IS THE SOLE
UNLESS OTHERWISE SPECIFIED:
MATERIAL: SIZE DWG. NO.

B
PROPERTY OF DEVICOR DIMENSIONS ARE IN INCHES
MEDICAL PRODUCTS INC. TOLERANCES:

.625 ANY REPRODUCTION IN PART ANGULAR: 1/2°


SEE NOTES TF-000102-001
G
OR AS A WHOLE WITHOUT THE TWO PLACE DECIMAL .01

C C WRITTEN PERMISSION OF THREE PLACE DECIMAL .005

4.750
DEVICOR MEDICAL PRODUCTS FOUR PLACE DECIMAL .0005 DRAWN BY: DATE:
INC., IS PROHIBITED. ERIK KLOSE 09/01/2017 SCALE: 4:5 SHEET 5 OF 8

8 7 6 5 4 3 2 1
Lifecycle: Lifecycle State: Drawing Revision:
PCO Number: ECN Number: Release Date: Effective Date:
8 7 6 5 4 3 2 1

D D

R.083

C C
.308

.071 .071

.073 .073 .234


.081
B B
.609

.020

.125

.134
A A

REVOLVE CUTTER
TITLE:

.188 SHARPNESS FTP TEST


PROPRIETARY
AND
CONFIDENTIAL
INTERPRET GEOMETRIC
TOLERANCING PER:
ASME Y14.5-2009
FIXTURE
THE INFORMATION CONTAINED UNLESS OTHERWISE SPECIFIED:
IN THIS DRAWING IS THE SOLE
MATERIAL: SIZE DWG. NO.

B
PROPERTY OF DEVICOR DIMENSIONS ARE IN INCHES
MEDICAL PRODUCTS INC. TOLERANCES:
ANY REPRODUCTION IN PART
OR AS A WHOLE WITHOUT THE
WRITTEN PERMISSION OF
ANGULAR: 1/2°
TWO PLACE DECIMAL
THREE PLACE DECIMAL
.01
.005
SEE NOTES TF-000102-002
DEVICOR MEDICAL PRODUCTS FOUR PLACE DECIMAL .0005 DRAWN BY: DATE:
INC., IS PROHIBITED. ERIK KLOSE 09/01/2017 SCALE: 4:1 SHEET 6 OF 8

8 7 6 5 4 3 2 1
Lifecycle: Lifecycle State: Drawing Revision:
PCO Number: ECN Number: Release Date: Effective Date:
8 7 6 5 4 3 2 1

.500 .062
J
.034 2X R.013
D D
.095 2X R.100
.362

4X R.063

R.375 .121
2.173 .061 R.031

.193
C C
DETAIL J
SCALE 6 : 1

B B

.192

.375 NOTE:
1. THIS GEAR HAS 52 TEETH, EQUALLY SPACED. REFER
TO DETAIL VIEW J FOR TOOTH DIMENTIONS.
2. THIS GEAR HAS 8 HOLES, THRU ALL , EQUALLY
.250 SPACED. REFER TO TOP VIEW FOR HOLE
A
DIMENSIONS. A

REVOLVE CUTTER
TITLE:

SHARPNESS FTP TEST


PROPRIETARY
AND
CONFIDENTIAL
INTERPRET GEOMETRIC
TOLERANCING PER:
ASME Y14.5-2009
FIXTURE
THE INFORMATION CONTAINED UNLESS OTHERWISE SPECIFIED:
IN THIS DRAWING IS THE SOLE
MATERIAL: SIZE DWG. NO.

B
PROPERTY OF DEVICOR DIMENSIONS ARE IN INCHES
MEDICAL PRODUCTS INC. TOLERANCES:
ANY REPRODUCTION IN PART
OR AS A WHOLE WITHOUT THE
WRITTEN PERMISSION OF
ANGULAR: 1/2°
TWO PLACE DECIMAL
THREE PLACE DECIMAL
.01
.005
SEE NOTES TF-000102-003
DEVICOR MEDICAL PRODUCTS FOUR PLACE DECIMAL .0005 DRAWN BY: DATE:
INC., IS PROHIBITED. ERIK KLOSE 09/01/2017 SCALE: 2:1 SHEET 7 OF 8

8 7 6 5 4 3 2 1
Lifecycle: Lifecycle State: Drawing Revision:
PCO Number: ECN Number: Release Date: Effective Date:
8 7 6 5 4 3 2 1

.875
D D

.213 THRU ALL

C C

.063

.034
.344
.250 2X R.013
.098

2X R.100
B B

R.031

.110
.747 .056
DETAIL K NOTE:
SCALE 8 : 1 1. THIS GEAR HAS 52 TEETH, EQUALLY SPACED. REFER TO
A DETAIL VIEW K FOR TOOTH DIMENTIONS. A

REVOLVE CUTTER
TITLE:

SHARPNESS FTP TEST


PROPRIETARY
AND
CONFIDENTIAL
INTERPRET GEOMETRIC
TOLERANCING PER:
ASME Y14.5-2009
FIXTURE
THE INFORMATION CONTAINED UNLESS OTHERWISE SPECIFIED:
IN THIS DRAWING IS THE SOLE
MATERIAL: SIZE DWG. NO.

B
PROPERTY OF DEVICOR DIMENSIONS ARE IN INCHES
MEDICAL PRODUCTS INC. TOLERANCES:
ANY REPRODUCTION IN PART
OR AS A WHOLE WITHOUT THE
WRITTEN PERMISSION OF
ANGULAR: 1/2°
TWO PLACE DECIMAL
THREE PLACE DECIMAL
.01
.005
SEE NOTES TF-000102-004
DEVICOR MEDICAL PRODUCTS FOUR PLACE DECIMAL .0005 DRAWN BY: DATE:
INC., IS PROHIBITED. ERIK KLOSE 09/01/2017 SCALE: 4:1 SHEET 8 OF 8