TRU-WELD Stud Welding
SHEAR CONNECTOR – FULL WELD BASE
(3/4” THRU DECK SHEAR CONNECTORS ON NEXT PAGE)
TYPE SC STUD
TYPE F FERRULE SUPPLIED
Head Diameter (HD) – 1‐1/4” for all 3/4 headed Shear Connectors.
Head Height (HT) – 3/8” for all 3/4 headed Shear Connectors.
D L TRU‐WELD Pieces Boxes Pieces
Box Pallet
1,000
Diameter Length Per Per Per Piece
Part Number Weight Weight
Box Pallet Pallet Weight
3/4 3-3/16 SC12‐051‐11 125 48 6,000 60 lbs. 2,880 lbs. 478 lbs.
3/4 3-11/16 SC12‐059‐11 100 48 4,800 55 lbs. 2,640 lbs. 548 lbs.
3/4 4-3/16 SC12‐067‐11 100 48 4,800 63 lbs. 3,024 lbs. 600 lbs.
3/4 4-11/16 SC12‐075‐11 75 27 2,025 51 lbs. 1,377 lbs. 672 lbs.
3/4 5-3/16 SC12‐083‐11 60 48 2,880 43 lbs. 2,064 lbs. 735 lbs.
3/4 5-11/16 SC12‐091‐11 60 48 2,880 47 lbs. 2.256 lbs. 783 lbs.
3/4 6-3/16 SC12‐099‐11 60 48 2,880 51 lbs. 2,448 lbs. 852 lbs.
3/4 6-11/16 SC12‐107‐11 80 27 2,160 75 lbs. 2,025 lbs. 938 lbs.
3/4 7-3/16 SC12‐115‐11 60 27 1,620 59 lbs. 1,593 lbs. 968 lbs.
3/4 8-3/16 SC12‐131‐11 50 27 1,350 56 lbs. 1,512 lbs. 1,105 lbs.
3/4 9-3/16 SC12‐147‐11 100 9 900 123 lbs. 1,107 lbs. 1,222 lbs.
3/4 10-3/16 SC12‐163‐11 100 9 900 137 lbs. 1,233 lbs. 1,339 lbs.
3/4 12-3/16 SC12‐195‐11 1,100 1 1,100 1,760 lbs. 1,760 lbs. 1,599 lbs.
3/4 16-3/16 SC12‐259‐11 1,000 1 1,000 2,000 lbs. 2,000 lbs. 2,000 lbs.
Shear Connectors are used in all types of concrete
connections. They can be welded to a flat surface, or to the Mechanical Property Requirements
inside or outside of an angle.
Type A Type B
Length: Length is listed before weld. Stud diameters 3/4” will
be approx. 3/16” shorter after weld. 61,000 psi 65,000 psi
Tensile Strength
TRU‐WELD shear connectors can be made in any length min. min.
above the standard minimum. 49,000 psi 51,000 psi
Yield Strength
Material: Low carbon steel, ASTM A29, 1010‐1020. SC Studs min. min.
are also available in weldable stainless steel. Type 302 is the Elongation (% in 2 in.) 17% min. 20% min.
most commonly used.
Elongation (% in 5x
14% min. 15% min.
dia.)
CHUCK FOOT GRIP FERRULE FOOT Reduction of Area 50% min. 50% min.
PART # PART # PART # PLATE (DUAL LEG)
CH‐075 B‐2C GC‐075 QN‐075 Type A Studs are general purpose studs.
Type B Studs are headed, bent, or of other configuration that
are used as an essential component in composite beam design
d t ti
TFP Corporation/TRU‐WELD (330) 725‐7741 http://www.tfpcorp.com
460 Lake Road (330) 725‐0161 Fax http://www.truweldstudwelding.com
Medina, Ohio 44256 Sales@tfpcorp.com http://www.weldstud.com
TRU-WELD Stud Welding
THRU‐DECK SHEAR CONNECTOR
TYPE DSC STUD
TYPE F FERRULE SUPPLIED
Head Diameter (HD) – 1‐1/4” for all 3/4” Thru‐Deck Shear Connectors.
Head Height (HT) – 3/8” for all 3/4” Thru‐Deck Shear Connectors.
WELD STUD SPECIFICATIONS WELD STUD PACKAGING WELD STUD WEIGHTS
D L TRU‐WELD Pieces Boxes Pieces
Box Pallet
1,000
Diameter Length Per Per Per Piece
Part Number Weight Weight
Box Pallet Pallet Weight
3/4 3-3/8 DSC12‐054‐11 125 48 6,000 62 lbs. 2,976 lbs. 500 lbs.
3/4 3-7/8 DSC12‐062‐11 100 48 4,800 58 lbs. 2,784 lbs. 567 lbs.
3/4 4-3/8 DSC12‐070‐11 100 48 4,800 62 lbs. 2,976 lbs. 634 lbs.
3/4 4-7/8 DSC12‐078‐11 75 48 3,600 51 lbs. 2,448 lbs. 701 lbs.
3/4 5-3/8 DSC12‐086‐11 60 48 2,880 45 lbs. 2,160 lbs. 754 lbs.
3/4 5-7/8 DSC12‐094‐11 60 48 2,880 49 lbs. 2,352 lbs. 810 lbs.
3/4 6-3/8 DSC12‐102‐11 60 48 2,880 53 lbs. 2,544 lbs. 883 lbs.
Thru‐Deck Shear Connectors are used in all types of concrete
Mechanical Property Requirements
connections. They can be welded to a flat surface, or to the
inside or outside of an angle.
Length: Length is listed before weld. Stud diameters 3/4” will Type A Type B
be approx. 3/8” shorter after weld.
TRU‐WELD thru‐deck shear connectors can be made in any 61,000 psi 65,000 psi
Tensile Strength
length above the standard minimum. min. min.
Material: Low carbon steel, ASTM A29, 1010‐1020. DSC Studs 49,000 psi 51,000 psi
Yield Strength
are also available in weldable stainless steel. Type 302 is the min. min.
most commonly used.
Elongation (% in 2 in.) 17% min. 20% min.
Elongation (% in 5x dia.) 14% min. 15% min.
CHUCK THRU‐DECK FOOT THRU‐DECK FERRULE
PART # ASSEMBLY GRIP Reduction of Area 50% min. 50% min.
B‐0021‐1A
CH‐075 B‐0060‐1 Type A Studs are general purpose studs.
B‐0021‐1P Type B Studs are headed, bent, or of other configuration that
are used as an essential component in composite beam design
and construction.
TFP Corporation/TRU‐WELD (330) 725‐7741 http://www.tfpcorp.com
460 Lake Road (330) 725‐0161 Fax http://www.truweldstudwelding.com
Medina, Ohio 44256 Sales@tfpcorp.com http://www.weldstud.com
TRU-WELD Stud Welding
SHEAR CONNECTOR – FULL WELD BASE
TYPE SC STUD
TYPE F FERRULE SUPPLIED
Head Diameter (HD) – 1‐3/8” for all 7/8” Shear Connectors.
Head Height (HT) – 3/8” for all 7/8” Shear Connectors.
WELD STUD SPECIFICATIONS WELD STUD PACKAGING WELD STUD WEIGHTS
D L TRU‐WELD Pieces Boxes Pieces
Box Pallet
1,000
Diameter Length Per Per Per Piece
Part Number Weight Weight
Box Pallet Pallet Weight
7/8 3-3/16 SC14‐051‐11 100 27 2,700 66 lbs. 1,782 lbs. 660 lbs.
7/8 3-11/16 SC14‐059‐11 100 27 2,700 74 lbs. 1,998 lbs. 709 lbs.
7/8 4-3/16 SC14‐067‐11 100 27 2,700 80 lbs. 2,160 lbs. 796 lbs.
7/8 5-3/16 SC14‐083‐11 75 27 2,025 73 lbs. 1,971 lbs. 961 lbs.
7/8 6-3/16 SC14‐099‐11 50 27 1,350 57 lbs. 1,539 lbs. 1,137 lbs.
7/8 7-3/16 SC14‐115‐11 45 27 1,215 59 lbs. 1,593 lbs. 1,306 lbs.
7/8 8-3/16 SC14‐131‐11 40 27 1,080 59 lbs. 1,593 lbs. 1,496 lbs.
7/8 9-3/16 SC14‐147‐11 75 9 675 125 lbs. 1,125 lbs. 1,666 lbs.
7/8 10-3/16 SC14‐163‐11 75 9 675 135 lbs. 1,215 lbs. 1,836 lbs.
7/8 12-3/16 SC14‐195‐11 825 1 825 1,793 lbs. 1,793 lbs. 2,173 lbs.
Shear Connectors are used in all types of concrete
Mechanical Property Requirements
connections. They can be welded to a flat surface, or to the
inside or outside of an angle.
Type A Type B
Length: Length is listed before weld. Stud diameters 7/8” will
be approx. 3/16”shorter after weld. 61,000 psi 65,000 psi
TRU‐WELD shear connectors can be made in any length above Tensile Strength
min. min.
the standard minimum. 49,000 psi 51,000 psi
Material: Low carbon steel, ASTM A29, 1010‐1020. SC Studs Yield Strength
min. min.
are also available in weldable stainless steel. Type 302 is the
most commonly used. Elongation (% in 2 in.) 17% min. 20% min.
Elongation (% in 5x
14% min. 15% min.
dia.)
CHUCK FOOT GRIP FERRULE FOOT
PART # PART # PART # PLATE (DUAL LEG) Reduction of Area 50% min. 50% min.
CH‐087 B‐3C GC‐087 QN‐087
Type A Studs are general purpose studs.
Type B Studs are headed, bent, or of other configuration that
are used as an essential component in composite beam design
and construction.
TFP Corporation/TRU‐WELD (330) 725‐7741 http://www.tfpcorp.com
460 Lake Road (330) 725‐0161 Fax http://www.truweldstudwelding.com
Medina, Ohio 44256 Sales@tfpcorp.com http://www.weldstud.com
TRU-WELD Stud Welding
SHEAR CONNECTOR – FULL WELD BASE
TYPE SC STUD
TYPE F FERRULE SUPPLIED
Head Diameter (HD) – 1‐5/8” for all 1” Shear Connectors.
Head Height (HT) – 1/2” for all 1” Shear Connectors.
WELD STUD SPECIFICATIONS WELD STUD PACKAGING WELD STUD WEIGHTS
D L TRU‐WELD Pieces Boxes Pieces
Box Pallet
1,000
Diameter Length Per Per Per Piece
Part Number Weight Weight
Box Pallet Pallet Weight
1” 3-1/4 SC16‐052‐11 75 27 2,025 70 lbs. 1,890 lbs. 894 lbs.
1” 4-1/4 SC16‐068‐11 50 27 1,350 57 lbs. 1,539 lbs. 1,079 lbs.
1” 5-1/4 SC16‐084‐11 50 27 1,350 70 lbs. 1,890 lbs. 1,302 lbs.
1” 6-1/4 SC16‐100‐11 40 27 1,080 63 lbs. 1,701lbs. 1,514 lbs.
1” 7-1/4 SC16‐116‐11 85 9 765 154 lbs. 1,386 lbs. 1,737 lbs.
1” 8-1/4 SC16‐132‐11 85 9 765 173 lbs. 1,557 lbs. 1,978 lbs.
1” 9-1/4 SC16‐148‐11 80 9 720 180 lbs. 1,620 lbs. 2,193 lbs.
Shear Connectors are used in all types of concrete
Mechanical Property Requirements
connections. They can be welded to a flat surface, or to the
inside or outside of an angle.
Length: Length is listed before weld. Stud diameters 1” will be Type A Type B
approx. 1/4” shorter after weld.
TRU‐WELD shear connectors can be made in any length above 61,000 psi 65,000 psi
Tensile Strength
the standard minimum. min. min.
Material: Low carbon steel, ASTM A29, 1010‐1020. SC Studs 49,000 psi 51,000 psi
Yield Strength
are also available in weldable stainless steel. Type 302 is the min. min.
most commonly used.
Elongation (% in 2 in.) 17% min. 20% min.
Elongation (% in 5x dia.) 14% min. 15% min.
CHUCK FOOT GRIP FERRULE FOOT
PART # PART # PART # PLATE (DUAL LEG) Reduction of Area 50% min. 50% min.
CH‐100 B‐3C GC‐100 QN‐100
Type A Studs are general purpose studs.
Type B Studs are headed, bent, or of other configuration that
are used as an essential component in composite beam design
and construction.
TFP Corporation/TRU‐WELD (330) 725‐7741 http://www.tfpcorp.com
460 Lake Road (330) 725‐0161 Fax http://www.truweldstudwelding.com
Medina, Ohio 44256 Sales@tfpcorp.com http://www.weldstud.com