501/453/RAC Group II Cable Glands
FFlameproof, Increased Safety, Dust Protection
'T' 'G'
Class - Zones - Divisions
'C' Certified ATEX / IECEx / c CSA us
Application
A
ø 'B'
'F'
'A'
Outdoor or indoor use.
For use with single wire armour ‘W’, wire braid ‘X’, steel
tape armour ‘Z’, elastomer and plastic insulated cables.
See technical section for installation rules and regulations.
CABLE GLAND SELECTION TABLE
Hexagon
Entry Thread Size 'F' Cable Acceptance Details
Dimensions
Size Inner Sheath ‘A’ Armour / Braid 'C'
“NPT * Outer Sheath 'B' ‘G’
Ref. Across Across
Metric Standard or Standard Seal Alternative Seal (S) Orientation Orientation Flats Corners
Option” Min. Max. Min. Max. Min. Max. 1 2
Os M20² ½" 3.2 8.0 - - 5.5 12.0 0.8 / 1.25 0.0 / 0.8 52.0 24.0 26.5
O M20² ½" 6.5 11.9 - - 9.5 16.0 0.8 / 1.25 0.0 / 0.8 52.0 24.0 26.5
A M20 ¾" or ½" 10.0 14.3 9.0 13.4 12.5 20.5 0.8 / 1.25 0.0 / 0.8 53.0 30.0 32.5
B M25 1" or ¾" 13.0 20.2 9.5 15.4 16.9 26.0 1.25 / 1.6 0.0 / 0.7 59.5 36.0 39.5
C M32 1¼" or 1" 19.5 26.5 15.5 21.2 22.0 33.0 1.6 / 2.0 0.0 / 0.7 64.0 46.0 50.5
C2 M40 1½" or 1¼" 25.0 32.5 22.0 28.0 28.0 41.0 1.6 / 2.0 0.0 / 0.7 68.3 55.0 60.6
D M50 2" or 1½" 31.5 44.4 / 42.3¹ 27.5 34.8 36.0 52.6 1.8 / 2.5 0.0 / 1.0 79.0 65.0 70.8
E M63 2½" or 2" 42.5 56.3 / 54.3¹ 39.0 46.5 46.0 65.3 1.8 / 2.5 0.0 / 1.0 78.4 80.0 88.0
F M75 3" or 2½" 54.5 68.2 / 65.3¹ 49.5 58.3 57.0 78.0 1.8 / 2.5 0.0 / 1.0 83.7 95.0 104.0
G M80 3½" 67.0 73.0 - - 75.0 89.5 2.0 / 3.5 0.0 / 1.0 95.6 106.4 115.0
H M90 3½" 67.0 77.6 - - 75.0 89.5 2.0 / 3.5 0.0 / 1.0 95.6 115.0 130.0
J M100 4" 75.0 91.6 - - 88.0 104.5 2.5 / 4.0 0.0 / 1.0 95.6 127.0 142.0
'T' — Os - F size metric entry threads are 1.5mm pitch as standard, 15mm length of thread. For G size glands and above, a 2mm pitch is supplied as
standard, 20mm length of thread (1.5mm pitch with 15mm length of thread can be supplied) please specify when ordering.
All dimensions in millimetres (except * where dimensions are in inches).
¹ Smaller value is applicable when selecting reduced NPT entry option.
² Sizes Os and O are available with an M16 thread size. For O size with M16 thread, the maximum cable inner sheath diameter is 10.9mm.
Technical Data Alternative Reversible Armour
ATEX/IECEx Clamping Rings (RAC)
Flameproof Exd IIC Gb, Increased Safety Exe IIC Gb and Dust Extb IIIC Db II 2 GD. SELECTION TABLE
Certificate No’s: Baseefa06ATEX0056X and IECEx BAS 06.0013X.Suitable for use in Zone 1, Size Steel Wire Armour / Braid / Tape
Zone 2, Zone 21, Zone 22 and in Gas Groups IIA, IIB and IIC. Ref. Orientation 1 Orientation 2
Construction and Test Standards: IEC/EN 60079-0, IEC/EN 60079-1, IEC/EN 60079-7 and IEC/EN B 0.9 - 1.25 0.5 - 0.9
C 1.2 - 1.6 0.6 - 1.2
60079-31.
C2 1.2 - 1.6 0.6 - 1.2
§ Ingress Protection: IP66, IP67 and IP 68* (30 metres for 7 days) to IEC/EN 60529 and NEMA 4X.
D 1.45 - 1.8 1.0 - 1.45
§ Deluge Protection to DTS01. (Deluge Seal Optional) E 1.45 - 1.8 1.0 - 1.45
§ Operating Temperature Range: -60°C to +100°C. F 1.45 - 1.8 1.0 - 1.45
§ Assembly Instruction Sheet: AI 302.
c CSA us
§ Flameproof AExd IIC Gb, Increased Safety AExe IIC Gb and Dust AExtD Zone 21.
§ Explosion-proof Class 1 Division 2 Groups ABCD, Class II Division 2 Groups EFG, Class III.
§ Certificate No’s: CSA1015065 for Marine Shipboard Cable.
Alternative certification options available:
Construction and Test Standards: UL 60079-0, UL 60079-1, UL 60079-7, ISA
60079-31, CSA 22.2 No: 60079-0, CSA 22.2 No: 60079-1, CSA 22.2 No: 60079-7, Ordering Information
CSA 22.2 No: 60079-31, UL 2225 Format for ordering is as follows:
Alternative Clamping Ring (AR), add suffix AR to
Features
ordering information. Alternative Seal (S), add suffix S
Provides armour clamping using one clamping arrangement for all
to ordering information.
armour / braid types.
Provides a seal on the cables inner sheath. Cable Gland
Size Thread Material (Optional)
Type
Provides a cable retention and low smoke and fume, zero halogen seal
onto the cables outer sheath. 501/453/RAC C M32 Brass AR
Manufactured in Brass (standard), Nickel Plated Brass, 316 Stainless Steel 501/453/RAC C 1 ¼" NPT Brass AR
or Aluminium. 501/453/RAC C M32 Brass S
Brass NPT entries are nickel plated as standard. 501/453/RAC C 1 ¼" NPT Brass S
Connection Solutions
86 * Additional installation procedures required
www.ehawke.com UPD 220217