                                Load, unload, or move trusses with the necessary personnel to assure that the trusses are
                                not dragged or dropped; this may damage the ends and the structure or result in other
                                unseen damage.
w w w. a rc o f a b. c o m
                                Load data
                                  - Are only valid for static loads and spans with two supporting points (one at each end);
                                  - Are to be considered for indoor use only. If dynamic loads or more supporting points
                                    are applied contact a structural engineer or Arcofab;
                                  - Are valid when the truss is used with the diagonals oriented vertically
                                    (see attached figures in page G-3);
                                  - Are valid when the end plates are installed vertically for the bolted trusses
                                    (see figure in page G-3 – note 1);
                                  - Are valid when the pins are installed horizontally for the spigoted trusses
                                    (see figure in page G-3 – note 2);
                                  - Take into consideration the self-weight of the trusses and indicate how much additional
                                    weight may be safely added;
                                  - Deflexions are theoretical (based on the rigidity of the truss when full loaded). Actual
                                    deflexion may be slightly higher because of possible movement between truss sections
                                    due to attachment tolerance;
                                  - When corner blocks are used, loading capacity must be reduce by 50% when corners
                                    are loaded on two adjacent faces.
                                                                                                                    10 / 2010   G-1
                   General
                      HANDLING, ASSEMBLY, AND USE OF TRUSSES
                                Inspection
                                Arcofab trusses are engineered and built to provide many years of reliable service provided
                                that they are used within the recommended loading parameters and handled properly.
                                Nuts, bolts, and washers should be replaced periodically as regular use degrades bolt
                                threads. Never over-torque nuts and bolts beyond manufacturer specifications and always
                                use Grade 8 nuts, bolts, and washers.
G-2    10 / 2010
               General
                  FIGURES
                             3   Typical hanging
                                 using two slings
w w w. a rc o f a b. c o m
                             4   Typical hanging
                                 using one sling
5 Symetrical loading
                                                                                  10 / 2010   G-3
               General
                  INSTALLATION OF ‘’CHANNEL’’ TYPE TRUSS
                                                                                                 10 / 2010   G-4
               General
                  INSPECTION AND MAINTENANCE
                             Inspection
                             A visual inspection of each section is required before every use. Furthermore, a complete
                             inspection shall be performed at least once a year (or more often depending on the
                             intensity and frequency of use). Every piece shall be carefully inspected by a competent
                             person in order to guarantee the strength and safety. Documentation on inspection
                             shall be registered and kept on file. Every inspected piece shall be clearly marked and
                             easy to identify.
                             When truss sections show damage that might affect the safety aspect, it is mandatory to
                             discard and mark them clearly so they won’t be put back into service. Damaged sections
                             can be submitted to Arcofab for evaluation and repair if possible. Should you have any
                             doubt, please contact Arcofab technical department.
                             Discard criteria
w w w. a rc o f a b. c o m
                             Any truss showing significant visible damage or suspected of containing a damaged
                             element (visible or not) shall be removed from service and marked accordingly.
                             General
                             All truss presenting the following damage must be removed from service:
                             s absence of any identification showing manufacturer, truss type and date of production.
                             s PERMANENT PLASTIC	 DISTORTION BY TWISTING BENDING TORSION OR ANY OTHER DEFORMATION
                              different of the original form.
                             s 7ELDS THAT SHOW CRACK OR DISCONTINUITY
                             s 2EDUCTION OF WELDED AREA DUE TO WEAR OR TEAR BY MORE THAT 
                             s !NY HOLES OTHER THAN THOSE OF THE ORIGINAL DESIGN
                             s Excessive corrosion of the material reducing the tube cross section area by more than 10.
                                                                                                                              10 / 2010   G-5
               General
                  INSPECTION AND MAINTENANCE
Connection systems
All connection systems presenting the following damage must be removed from service:
Spigot type
                             s Any piece of an oval form into metal pin holes enlarged by wear over 5%. See Figure 5.
                             s !N OVAL
SHAPED WEAR OR STRETCH	 COIL SPRING PIN HOLE OVER %. See Figure 6.
                             s 3CRATCHES CUTS OR HAMMER BLOW OR ELSE DEEPER THAN  MM	 AND LONGER THAN
                                MM	
                             s !NY DEFORMATION OR DISTORTION RESULTING IN DIFFICULTIES IN JOINING ADJACENT TRUSS SECTION
                               or installing the pins.
                             4HESE ITEMS ARE hCONSUMABLESv AND SUBJECT TO WEAR AND GET DAMAGED BY HAMMER AND
                             wrench. These parts have to be replaced on a regular basis. Also they give good indica-
                             TION OF EXCESSIVE LOADING BY SHOWING DEFORMATION SURFACE WORKS AND BENDING
                             It is recommended to inspect carefully the trusses connected with steel pins or bolts
                             presenting any damage.
                             All steel pin and bolt presenting the following damage must be removed from service:
                             s SURFACE DAMAGE SCRATCHES CUTS DENTS CORROSION
                             s 3HAPE DAMAGE REDUCTION IN DIAMETER BENDING SHEAR MARK THREAD DAMAGE ANY
                               DEFORMATION BY HAMMERING BURRS MUSHROOMS ETC	
WARNING
                             .EGLECT OF INSPECTION AND MAINTENANCE OF THE TRUSS AT REGULAR INTERVALS MIGHT EVENTUALLY
                             LEAD TO THE USE OF UNSAFE EQUIPMENT RESULTING IN RISK OF ACCIDENT MATERIAL DAMAGE
                             INJURIES OR EVEN DEATH	
                                                                                                                           10 / 2010   G-6
               General
                  INSPECTION AND MAINTENANCE
w w w. a rc o f a b. c o m
                                                                                 10 / 2010   G-7
               General
                  STANDARD TRUSS CODE
                                                                WHEELS (OPTIONAL)
                                                                THREADED SPIGOT (OPTIONAL)
                                                                ADDITIONAL BRACES FOR SEISMIC LOAD (OPTIONAL)
                                                                S-SPIGOT
                                                                B-PLATES AND BOLTS
T = TRUSS
                                                                                                                10 / 2010   G-8
               General
                  STANDARD CORNER BLOCK CODE
                                                                WHEELS (OPTIONAL)
                                                                THREADED SPIGOT (OPTIONAL)
                                                                ADDITIONAL BRACES FOR SEISMIC LOAD (OPTIONAL)
                                                                S-SPIGOT
                                                                B-PLATES AND BOLTS
C = CORNER BLOCK
                                                                                                                10 / 2010   G-9
               Accessories
                   PINS, BARS, CLAMPS, BOLT AND HOOKS
Pins
                                 Bars
w w w. a rc o f a b. c o m
Several models of Bars are available, please contact us for more information
                                 A5000016                             A5000017
                                  (male)                               (female)
                                                                                                                                10 / 2010   A-1
                  Accessories
                      TRUSS HANGERS, PLATES, OUT RIGGER AND HINGES
Truss Hangers
w w w. a rc o f a b. c o m
                                       1212, 1616, 2020, 3020, 3022.
                                               A5000058                           A5000059
                                                 (steel)                         (aluminum)                  0490-A-12
                                             Available dimensions:
                                      1212, 1616, 2020 spygot or bolted
Hinges
A-2   10 / 2010
               Accessories
                   LADDERS, CORNER AND ROLLER BLOCKS
Ladders
Several models of Corner Blocks are available, please contact us for more information
Roller Blocks
Several models of Roller Blocks are available, please contact us for more information
                                                                                                                              10 / 2010   A-3
                  Accessories
                      RACKS, PROJECTOR BARS, TRUSS DOLLY AND SPOT CHAIR
w w w. a rc o f a b. c o m
A5000010 A5000013
                                TRUSS DOLLY
                                Available dimensions: 1212, 1616 and 2020.                A5000019
A-4   10 / 2010
                              Theatre Series
                                  1206 MEDIUM DUTY TRUSS SPIGOTED                                       TTB-1206-S
                                                                                                        TTD-1206-S
w w w. a rc o f a b. c o m
                                                                           TTB Series
                                                                           Main chords: 2.0" OD x 0.188"
                                                                                                                   10 / 2010   T-1
          Theatre Series                                                                                                    TTB-1206-S
             1206 MEDIUM DUTY TRUSS SPIGOTED
                                                                                                                            TTD-1206-S
                            ALLOWABLE
                                    LOAD DATA
                                             Uniformly distributed load                                    Concentrated load
      Notes                 s   Data presented in this chart apply to trusses built after January 2002.
                            s   Trusses must be loaded symmetrically on each side.
                            s   All loads must be applied at, or as close as possible to, node points (see General Section).
                            s   Deflexions are based on the rigidity of the trusses and do not include
                                possible movement between trusses due to attachment tolerance.
                            s   For span exceeding 20' (6m), loads are for laterally supported truss.
                            s   Data are valid for inside use only.
                            s   Data are only valid for static loads and spans with two supporting points (span must be supported at each end).
                                If dynamic loads or more supporting points are applied, contact a professional engineer or Arcofab.
T-2   10 / 2010
                            Exposition Series
                               1212 LIGHT DUTY TRUSS PLATED                                           TEA-1212-B
                                                                                                      TEC-1212-B
w w w. a rc o f a b. c o m
                                                                         TEA Series
                                                                         Main chords: 2.0" OD x 0.125"
                                                                                                                 10 / 2010   T-3
         Exposition Series                                                                                                 TEA-1212-B
            1212 LIGHT DUTY TRUSS PLATED
                                                                                                                           TEC-1212-B
                           ALLOWABLE
                                   LOAD DATA
                                            Uniformly distributed load                                    Concentrated load
      Notes                s  Data presented in this chart apply to trusses built after January 2002.
                           s  Trusses must be loaded symmetrically on each side.
                           s All loads must be applied at, or as close as possible to, node points (see General Section).
                           s Deflexions are based on the rigidity of the trusses and do not include
                              possible movement between trusses due to attachment tolerance.
                           s Data are valid for inside use only.
                           s Data are only valid for static loads and spans with two supporting points (span must be supported at each end).
                             If dynamic loads or more supporting points are applied, contact a professional engineer or Arcofab.
T-4   10 / 2010
                             Exposition Series
                                1212 LIGHT DUTY TRUSS SPIGOTED                                       TEA-1212-S
                                                                                                     TEC-1212-S
w w w. a rc o f a b. c o m
                                                                        TEA Series
                                                                        Main chords: 2.0" OD x 0.125"
                                                                                                                10 / 2010   T-5
         Exposition Series                                                                                                 TEA-1212-S
            1212 LIGHT DUTY TRUSS SPIGOTED
                                                                                                                           TEC-1212-S
                           ALLOWABLE
                                   LOAD DATA
                                            Uniformly distributed load                                    Concentrated load
      Notes                s  Data presented in this chart apply to trusses built after January 2002.
                           s  Trusses must be loaded symmetrically on each side.
                           s All loads must be applied at, or as close as possible to, node points (see General Section).
                           s Deflexions are based on the rigidity of the trusses and do not include
                              possible movement between trusses due to attachment tolerance.
                           s Data are valid for inside use only.
                           s Data are only valid for static loads and spans with two supporting points (span must be supported at each end).
                             If dynamic loads or more supporting points are applied, contact a professional engineer or Arcofab.
T-6   10 / 2010
                               Theatre Series
                                   1212 LIGHT DUTY TRUSS PLATED                                         TTA-1212-B
                                                                                                        TTC-1212-B
w w w. a rc o f a b. c o m
                                                                           TTA Series
                                                                           Main chords: 2.0" OD x 0.125"
                                                                                                                   10 / 2010   T-7
          Theatre Series                                                                                                    TTA-1212-B
             1212 LIGHT DUTY TRUSS PLATED
                                                                                                                            TTC-1212-B
                            ALLOWABLE
                                    LOAD DATA
                                             Uniformly distributed load                                    Concentrated load
      Notes                 s  Data presented in this chart apply to trusses built after January 2002.
                            s  Trusses must be loaded symmetrically on each side.
                            s All loads must be applied at, or as close as possible to, node points (see General Section).
                            s Deflexions are based on the rigidity of the trusses and do not include
                               possible movement between trusses due to attachment tolerance.
                            s Data are valid for inside use only.
                            s Data are only valid for static loads and spans with two supporting points (span must be supported at each end).
                              If dynamic loads or more supporting points are applied, contact a professional engineer or Arcofab.
T-8   10 / 2010
                             Theatre Series
                                 1212 MEDIUM DUTY TRUSS SPIGOTED                                        TTB-1212-S
                                                                                                        TTD-1212-S
w w w. a rc o f a b. c o m
                                                                           TTB Series
                                                                           Main chords: 2.0" OD x 0.188"
                                                                                                                   10 / 2010   T-9
           Theatre Series                                                                                                    TTB-1212-S
              1212 MEDIUM DUTY TRUSS SPIGOTED
                                                                                                                             TTD-1212-S
                             ALLOWABLE
                                     LOAD DATA
                                              Uniformly distributed load                                    Concentrated load
       Notes                 s  Data presented in this chart apply to trusses built after January 2002.
                             s  Trusses must be loaded symmetrically on each side.
                             s All loads must be applied at, or as close as possible to, node points (see General Section).
                             s Deflexions are based on the rigidity of the trusses and do not include
                                possible movement between trusses due to attachment tolerance.
                             s Data are valid for inside use only.
                             s Data are only valid for static loads and spans with two supporting points (span must be supported at each end).
                               If dynamic loads or more supporting points are applied, contact a professional engineer or Arcofab.
T-10   10 / 2010
                           Tower Series
                                          1212 LIGHT DUTY TRUSS PLATED                                       TWB-1212-B
                                                                                                             TWD-1212-B
w w w. a rc o f a b. c o m
                                                                                  TWB Series
                                                                                  Main chords:   2.0" OD x 0.188"
                                                                                                                         10 / 2010   T-11
           Tower Series
                    1212 LIGHT DUTY TRUSS PLATED                                                                          TWB-1212-B
                                                                                                                          TWD-1212-B
                             ALLOWABLE
                                      LOAD DATA
                                                Uniformly distributed load                                   Concentrated load
                             s Data  presented in this chart apply to trusses built after January 2002.
        Notes
                             s Trusses must be loaded symmetrically on each side.
                             s All loads must be applied at, or as close as possible to, node points (see section General).
s Deflexions are based on the rigidity of the trusses and do not include possible movement
T-12   10 / 2010
                           Tower Series
                                          1212 MEDIUM DUTY TRUSS SPIGOTED                                   TWB-1212-S
                                                                                                            TWD-1212-S
w w w. a rc o f a b. c o m
                                                                                 Série TWB
                                                                                 Main chords:   2.0" OD x 0.188"
                                                                                                                        10 / 2010   T-13
           Tower Series
                1212 MEDIUM DUTY TRUSS SPIGOTED                                                                           TWB-1212-S
                                                                                                                          TWD-1212-S
                             ALLOWABLE
                                      LOAD DATA
                                                Uniformly distributed load                                   Concentrated load
       Notes                 s Data   presented in this chart apply to trusses built after January 2002.
                              s Trusses must be loaded symmetrically on each side.
                              s All loads must be applied at, or as close as possible to, node points (see section General).
                              s Deflexions are based on the rigidity of the trusses and do not include possible movement
                                between trusses due to attachment tolerance.
                             s Data are valid for inside use only.
                             s Data are only valid for static loads and spans with two supporting points (span must be supported at each end).
If dynamic loads or more supporting points are applied, contact a professional engineer or Arcofab.
T-14   10 / 2010
                       Tripod Series
                           12 FIXED TRIANGLE LIGHT DUTY TRUSS SPIGOTED                          TDA-12FX-S
                                                                                                TDC-12FX-S
w w w. a rc o f a b. c o m
                                                                   TDA Series
                                                                   Main chords: 2.0" OD x 0.125"
                                               Plan
                  8c
               0,4
                                                                                                           10 / 2010   T-15
           Tripod Series                                                                                                     TDA-12FX-S
               12 FIXED TRIANGLE LIGHT DUTY TRUSS SPIGOTED
                                                                                                                             TDC-12FX-S
                             ALLOWABLE
                                     LOAD DATA
                                              Uniformly distributed load                                    Concentrated load
       Notes                 s  Data presented in this chart apply to trusses built after January 2002.
                             s  Trusses must be loaded symmetrically on each side.
                             s All loads must be applied at, or as close as possible to, node points (see General Section).
                             s Deflexions are based on the rigidity of the trusses and do not include
                                possible movement between trusses due to attachment tolerance.
                             s Data are valid for inside use only.
                             s Data are only valid for static loads and spans with two supporting points (span must be supported at each end).
                               If dynamic loads or more supporting points are applied, contact a professional engineer or Arcofab.
T-16   10 / 2010
                              Exposition Series
                                 1616 MEDIUM DUTY TRUSS PLATED                                         TEA-1616-B
                                                                                                       TEC-1616-B
w w w. a rc o f a b. c o m
                                                                          TEA Series
                                                                          Main chords: 2.0" OD x 0.125"
                                                                                                                  10 / 2010   T-17
          Exposition Series                                                                                                 TEA-1616-B
             1616 MEDIUM DUTY TRUSS PLATED
                                                                                                                            TEC-1616-B
                            ALLOWABLE
                                    LOAD DATA
                                             Uniformly distributed load                                    Concentrated load
       Notes                s   Data presented in this chart apply to trusses built after January 2002.
                            s   Trusses must be loaded symmetrically on each side.
                            s   All loads must be applied at, or as close as possible to, node points (see General Section).
                            s   Deflexions are based on the rigidity of the trusses and do not include
                                possible movement between trusses due to attachment tolerance.
                            s   Data are valid for inside use only.
                            s   Data are only valid for static loads and spans with two supporting points (span must be supported at each end).
                                If dynamic loads or more supporting points are applied, contact a professional engineer or Arcofab.
T-18   10 / 2010
                              Exposition Series
                                 1616 MEDIUM DUTY TRUSS SPIGOTED                                          TEA-1616-S
                                                                                                          TEC-1616-S
w w w. a rc o f a b. c o m
                                                                             TEA Series
                                                                             Main chords: 2.0” OD x 0.125”
                                                                                                                     10 / 2010   T-19
                      Exposition Series
                             ALLOWABLE
                                     LOAD DATA
                                              Uniformly distributed load                                    Concentrated load
       Notes                 s   Data presented in this chart apply to trusses built after January 2002.
                             s   Trusses must be loaded symmetrically on each side.
                             s   All loads must be applied at, or as close as possible to, node points (see General Section).
                             s   Deflexions are based on the rigidity of the trusses and do not include
                                 possible movement between trusses due to attachment tolerance.
                             s   Data are valid for inside use only.
                             s   Data are only valid for static loads and spans with two supporting points (span must be supported at each end).
                                 If dynamic loads or more supporting points are applied, contact a professional engineer or Arcofab.
T-20   10 / 2010
                              Tower Series
                                          1616 MEDIUM DUTY TRUSS PLATED                                     TWB-1616-B
                                                                                                            TWD-1616-B
w w w. a rc o f a b. c o m
                                                                                 TWB Series
                                                                                 Main chords:   2.0" OD x 0.188"
                                                                                                                        10 / 2010   T-21
           Tower Series
                    1616 MEDIUM DUTY TRUSS PLATED                                                                         TWB-1616-B
                                                                                                                          TWD-1616-B
                             ALLOWABLE
                                      LOAD DATA
                                                Uniformly distributed load                                   Concentrated load
       Notes                 s Data  presented in this chart apply to trusses built after January 2002.
                             s Trusses must be loaded symmetrically on each side.
                             s All loads must be applied at, or as close as possible to, node points (see section General).
s Deflexions are based on the rigidity of the trusses and do not include possible movement
T-22   10 / 2010
                              Tower Series
                                          1616 MEDIUM DUTY TRUSS SPIGOTED                                   TWB-1616-S
                                                                                                            TWD-1616-S
w w w. a rc o f a b. c o m
                                                                                 TWB Series
                                                                                 Main chords:   2.0" OD x 0.188"
                                                                                                                        10 / 2010   T-23
           Tower Series
                    1616 MEDIUM DUTY TRUSS SPIGOTED                                                                    TWB-1616-S
                                                                                                                       TWD-1616-S
                             ALLOWABLE
                                     LOAD DATA
                                                Uniformly distributed load                                  Concentrated load
       Notes                 s !"#"  $%&'&(#&) *( #+*' ,+"%# "$$-. #/ #%0''&' 10*-# "2#&% 3"(0"%. 45546
                             s 7%0''&'  80'# 1& -/")&) '.88&#%*,"--. /( &",+ '*)&6
                             s 9-- -/")' 80'# 1& "$$-*&) "#: /% "' ,-/'& "' $/''*1-& #/: (/)& $/*(#' ;'&& '&,#*/( <&(&%"-=6
                             s !&2-&>*/(' "%& 1"'&) /( #+& %*?*)*#. /2 #+& #%0''&' "() )/ (/# *(,-0)& $/''*1-& 8/@&8&(#
                               1&#A&&( #%0''&' )0& #/ "##",+8&(# #/-&%"(,&6
                             s !"#"B"%&B@"-*)B2/%B*('*)&B0'&B/(-.6
                             s !"#"B"%&B/(-.B@"-*)B2/%B'#"#*,B-/")'B"()B'$"('BA*#+B#A/B'0$$/%#*(?B$/*(#'B;'$"(B80'#B1&
                               '0$$/%#&)B"#B&",+B&()=6BC2B).("8*,B-/")'B/%B8/%&B'0$$/%#*(?B$/*(#'B"%&B"$$-*&):B,/(#",#
                               "B$%/2&''*/("-B&(?*(&&%B/%B9%,/2"16
T-24   10 / 2010
                            Channel Series
                               1616 MEDIUM DUTY TRUSS SPIGOTED                                                                              TCB-1616-S
                                                                                                                                            TCD-1616-S
w w w. a rc o f a b. c o m
                                                                                                               TCB Series
                                                                                                               Main chords: 2.0" OD x 0.188"
                                                                                                                                                       10 / 2010   T-25
           Channel Series                                                                                                    TCB-1616-S
              1616 MEDIUM DUTY TRUSS SPIGOTED
                                                                                                                             TCD-1616-S
                             ALLOWABLE
                                     LOAD DATA
                                              Uniformly distributed load                                    Concentrated load
       Notes                 s   Data presented in this chart apply to trusses built after January 2002.
                             s   Trusses must be loaded symmetrically on each side.
                             s   All loads must be applied at, or as close as possible to, node points (see General Section).
                             s   Deflexions are based on the rigidity of the trusses and do not include
                                 possible movement between trusses due to attachment tolerance.
                             s   Installation of spreader bars is required at hang points.
                             s   Data are valid for inside use only.
                             s   Data are only valid for static loads and spans with two supporting points (span must be supported at each end).
                                 If dynamic loads or more supporting points are applied, contact a professional engineer or Arcofab.
T-26   10 / 2010
                                    Tour Series
                                        2020 HEAVY DUTY TRUSS PLATED                                              TRA-2020-B
                                                                                                                  TRC-2020-B
w w w. a rc o f a b. c o m
                                                                                     TRA Series
                                                                                     Main chords: 2.0" OD x 0.125"
                                                                                                                             10 / 2010   T-27
           Tour Series                                                                                                     TRA-2020-B
              2020 HEAVY DUTY TRUSS PLATED
                                                                                                                           TRC-2020-B
                             ALLOWABLE
                                     LOAD DATA
                                              Uniformly distributed load                                    Concentrated load
       Notes                 s   Data presented in this chart apply to trusses built after January 2002.
                             s   Trusses must be loaded symmetrically on each side.
                             s   All loads must be applied at, or as close as possible to, node points (see General Section).
                             s   Deflexions are based on the rigidity of the trusses and do not include
                                 possible movement between trusses due to attachment tolerance.
                             s   Data are valid for inside use only.
                             s   Data are only valid for static loads and spans with two supporting points (span must be supported at each end).
                                 If dynamic loads or more supporting points are applied, contact a professional engineer or Arcofab.
T-28   10 / 2010
                                 Tour Series
                                     2020 HEAVY DUTY TRUSS SPIGOTED                                             TRB-2020-S
                                                                                                                TRD-2020-S
w w w. a rc o f a b. c o m
                                                                                   TRB Series
                                                                                   Main chords: 2.0" OD x 0.188"
                                                                                                                           10 / 2010   T-29
           Tour Series                                                                                                       TRB-2020-S
              2020 HEAVY DUTY TRUSS SPIGOTED
                                                                                                                             TRD-2020-S
                             ALLOWABLE
                                     LOAD DATA
                                              Uniformly distributed load                                    Concentrated load
       Notes                 s   Data presented in this chart apply to trusses built after January 2002.
                             s   Trusses must be loaded symmetrically on each side.
                             s   All loads must be applied at, or as close as possible to, node points (see General Section).
                             s   Deflexions are based on the rigidity of the trusses and do not include
                                 possible movement between trusses due to attachment tolerance.
                             s   Data are valid for inside use only.
                             s   Data are only valid for static loads and spans with two supporting points (span must be supported at each end).
                                 If dynamic loads or more supporting points are applied, contact a professional engineer or Arcofab.
T-30   10 / 2010
                                 Tower Series
                                                2020 HEAVY DUTY TRUSS PLATED                                      TWB-2020-B
                                                                                                                  TWD-2020-B
w w w. a rc o f a b. c o m
                                                                                       TWB Series
                                                                                       Main chords:   2.0" OD x 0.188"
                                                                                                                              10 / 2010   T-31
           Tower Series
                    2020 HEAVY DUTY TRUSS PLATED                                                                          TWB-2020-B
                                                                                                                          TWD-2020-B
                             ALLOWABLE
                                      LOAD DATA
                                                Uniformly distributed load                                   Concentrated load
       Notes                 s Data  presented in this chart apply to trusses built after January 2002.
                             s Trusses must be loaded symmetrically on each side.
                             s All loads must be applied at, or as close as possible to, node points (see section General).
                             s Deflexions are based on the rigidity of the trusses and do not include possible movement
                               between trusses due to attachment tolerance.
                             s Data are valid for inside use only.
                             s Data are only valid for static loads and spans with two supporting points (span must be supported at each end).
                               If dynamic loads or more supporting points are applied, contact a professional engineer or Arcofab.
T-32   10 / 2010
                                 Tower Series
                                                2020 HEAVY DUTY TRUSS SPIGOTED                                    TWB-2020-S
                                                                                                                  TWD-2020-S
w w w. a rc o f a b. c o m
                                                                                       TWB Series
                                                                                       Main chords:   2.0" OD x 0.188"
                                                                                                                              10 / 2010   T-33
          Tower Series
                    2020 HEAVY DUTY TRUSS SPIGOTED                                                                         TWB-2020-S
                                                                                                                           TWD-2020-S
                             ALLOWABLE
                                      LOAD DATA
                                                Uniformly distributed load                                    Concentrated load
       Notes                 s Data  presented in this chart apply to trusses built after January 2002.
                             s Trusses must be loaded symetrically on each side.
                             s All loads must be applied at, or as close as possible to, node points (see section General).
                             s Deflexions are based on the rigidity of the trusses and do not include possible movement
                               between trusses due to attachment tolerance.
                             s Data are valid for inside use only.
                             s Data are only valid for static loads and spans with two supporting points (span must be supported at each end).
                               If dynamic loads or more supporting points are applied, contact a professional engineer or Arcofab.
T-34   10 / 2010
                                  Channel Series
                                     2020 HEAVY DUTY TRUSS SPIGOTED                                                                                  TCB-2020-S
                                                                                                                                                     TCD-2020-S
w w w. a rc o f a b. c o m
                                                                                                                        TCB Series
                                                                                                                        Main chords: 2.0" OD x 0.188"
                                                                                                                                                                10 / 2010   T-35
          Channel Series                                                                                                    TCB-2020-S
             2020 HEAVY DUTY TRUSS SPIGOTED
                                                                                                                            TCD-2020-S
                            ALLOWABLE
                                    LOAD DATA
                                             Uniformly distributed load                                    Concentrated load
       Notes                s  Data presented in this chart apply to trusses built after January 2002.
                            s  Trusses must be loaded symmetrically on each side.
                            s All loads must be applied at, or as close as possible to, node points (see General Section).
                            s Deflexions are based on the rigidity of the trusses and do not include
                               possible movement between trusses due to attachment tolerance.
                            s Installation of spreader bars is required at hang points.
                            s Data are valid for inside use only.
                            s Data are only valid for static loads and spans with two supporting points (span must be supported at each end).
                              If dynamic loads or more supporting points are applied, contact a professional engineer or Arcofab.
T-36   10 / 2010
                              Tripod Series
                                            20 FIXED TRIANGLE MEDIUM DUTY TRUSS SPIGOTED TDB-20FX-S
                                                                                                                TDD-20FX-S
w w w. a rc o f a b. c o m
                                                                                   TDB Series
                                                                                   Main chords: 2.0" OD x 0.188"
                                                                                                                           10 / 2010   T-37
          Tripod Series                                                                                                      TDB-20FX-S
              20 FIXED TRIANGLE MEDIUM DUTY TRUSS SPIGOTED
                                                                                                                             TDD-20FX-S
                             ALLOWABLE
                                     LOAD DATA
                                              Uniformly distributed load                                    Concentrated load
       Notes                 s  Data presented in this chart apply to trusses built after January 2002.
                             s  Trusses must be loaded symmetrically on each side.
                             s All loads must be applied at, or as close as possible to, node points (see General Section).
                             s Deflexions are based on the rigidity of the trusses and do not include
                                possible movement between trusses due to attachment tolerance.
                             s Data are valid for inside use only.
                             s Data are only valid for static loads and spans with two supporting points (span must be supported at each end).
                               If dynamic loads or more supporting points are applied, contact a professional engineer or Arcofab.
T-38   10 / 2010
            Mother Grid Series
               3020 HEAVY DUTY TRUSS SPIGOTED WITH WHEELS                                                            TMB-3020-SW
                                                                                                                     TMD-3020-SW
                                                                                                      Threaded
                                                                                                    spigots option
                                                                                                       for TMB
w w w. a rc o f a b. c o m
                                                                                       TMB Series
                                                                                       Main chords: 2.0" OD x 0.188"
                                                  Threaded
                                                spigots option                         Diagonals:     1.5" OD x 0.125"
                                                   for TMB
                                                                                       Material:      Aluminum 6061-T6 extrusions
                                                                                                                               10 / 2010   T-39
           Mother Grid Series                                                                                             TMB-3020-SW
              3020 HEAVY DUTY TRUSS SPIGOTED WITH WHEELS
                                                                                                                          TMD-3020-SW
                              ALLOWABLE
                                      LOAD DATA
                                               Uniformly distributed load                                   Concentrated load
       Notes                  s   Data presented in this chart apply to trusses built after January 2002.
                              s   Trusses must be loaded symmetrically on each side.
                              s   All loads must be applied at, or as close as possible to, node points (see General Section).
                              s   Deflexions are based on the rigidity of the trusses and do not include
                                  possible movement between trusses due to attachment tolerance.
                              s   For span exceeding 60' (18m), loads are for laterally supported truss.
                              s   Data are valid for inside use only.
                              s   Data are only valid for static loads and spans with two supporting points (span must be supported at each end).
                                  If dynamic loads or more supporting points are applied, contact a professional engineer or Arcofab.
T-40   10 / 2010
           Mother Grid Series
              3020 HEAVY DUTY TRUSS SPIGOTED WITH WHEELS                                          TMB-3020-SW
                                                                                                  TMD-3020-SW
w w w. a rc o f a b. c o m
                                                                                                        10 / 2010   T-41
                          Mother Grid Seismic Series                                                          TMB-3020-SSTW
                                          3020 HEAVY DUTY TRUSS WITH THREADED SPIGOTS WITH WHEELS
                                                                                                                       Click here
                                                                                                                       for detail
w w w. a rc o f a b. c o m
                                                Click here
                                                for detail
                                                                                     TMB Series
                                                             120’’ (304.80 cm)       Main chords:   2.0" OD x 0.188"
                                                                    Plan
                                                                                     Diagonals:     1.5" OD x 0.125"
          30” (76,4 cm)
1.0" OD x 0.125"
                                                                                                                               10 / 2010   T-42
           Mother Grid Seismic Series
                3020 HEAVY DUTY TRUSS WITH THREADED SPIGOTS WITH WEELS                                                     TMB-3020-SSTW
                                                                                                                           STRONG WAY
                             ALLOWABLE
                                      LOAD DATA
                   20
                                              Uniformly distributed load                                          Concentrated load
           30
                                                                       TMB-3020-SST
                                                                       Main chords : 2,0" OD x 0,188”
                                                                       Diagonals : 1,5" OD x 0,125"
                                                                                   1,0" OD x 0,125"
                                    Description                     Item                       Weight lb (kg)
                                  8’ - 30” x 20.5”          TMB-3020-096SST                        133   (60.3)
                                  4’ - 30” x 20.5”          TMB-3020-048SST                        88    (39.9)
                             s   Other lengths and accessories are available if requested.
T-43   10 / 2010
           Mother Grid Seismic Series
                    3020 HEAVY DUTY WITH THREADED SPIGOTS WITH WHEELS                                                       TMB-3020-SSTW
                                                                                                                            WEAK WAY
                             ALLOWABLE
                                     LOAD DATA
             30                              Uniformly distributed load                                           Concentrated load
                      20
                                                                      TMB-3020-SST
                                                                     Main chords : 2.0" OD x 0.188"
                                                                       Diagonals : 1.5" OD x 0.125"
                                                                                   1.0" OD x 0.125"
                                    Description                    Item                       Weight lb (kg)
                                  8’ - 30” x 20.5”          TMB-3020-096SST                        133   (60.3)
                                  4’ - 30” x 20.5”          TMB-3020-048SST                        88    (39.9)
T-44   10 / 2010
       Mother Grid Seismic Series
   3020 HEAVY DUTY TRUSS THREADED SPIGOTS WITH WHEELS                        TMB-3020-SSTW
w w w. a rc o f a b. c o m
                                                                                    10 / 2010   T-45
                           Channel Series
                                            3020 HEAVY DUTY TRUSS SPIGOTED                                                                         TCB-3020-S
                                                                                                                                                   TCD-3020-S
w w w. a rc o f a b. c o m
                                                                                                                        TCB Series
                                                                                                                        Main chords:   2.0" OD x 0.188"
                                                                                                                                                               10 / 2010   T-46
          Channel Series
                    3020 HEAVY DUTY TRUSS SPIGOTED                                                                          TCB-3020-S
                                                                                                                            TCD-3020-S
                             ALLOWABLE
                                      LOAD DATA
                                                Uniformly distributed load                                     Concentrated load
       Notes                 s Data  presented in this chart apply to trusses built after January 2002.
                             s Trusses must be loaded symetrically on each side.
                             s All loads must be applied at, or as close as possible to, node points (see section General).
                             s Deflexions are based on the rigidity of the trusses and do not include possible movement
                               between trusses due to attachment tolerance.
                             s Data are valid for inside use only.
                             s Data are only valid for static loads and spans with two supporting points (span must be supported at each end).
                               If dynamic loads or more supporting points are applied, contact a professional engineer or Arcofab.
T-47   10 / 2010
                           Mother Grid Series
                              3024 HEAVY DUTY TRUSS PLATED WITH WHEELS                                TMA-3024-BW
                                                                                                      TMC-3024-BW
w w w. a rc o f a b. c o m
                                                                            TMA Series
                                                                            Main chords: 2.0" OD x 0.125"
                                                                                                                    10 / 2010   T-48
           Mother Grid Series                                                                                          TMA-3024-BW
              3024 HEAVY DUTY TRUSS PLATED WITH WHEELS
                                                                                                                       TMC-3024-BW
                             ALLOWABLE
                                     LOAD DATA
                                              Uniformly distributed load                                 Concentrated load
        Notes                s  Data presented in this chart apply to trusses built after January 2002.
                             s  Trusses must be loaded symmetrically on each side.
                             s All loads must be applied at, or as close as possible to, node points (see General Section).
                             s Deflexions are based on the rigidity of the trusses and do not include
                                possible movement between trusses due to attachment tolerance.
                             s Data are valid for inside use only.
                             s Data are only valid for static loads and spans with two supporting points (span must be supported at each end).
                               If dynamic loads or more supporting points are applied, contact a professional engineer or Arcofab.
T-49   10 / 2010
                             Mother Grid Series
                                      3024 HEAVY DUTY TRUSS SPIGOTED                                                         TMB-3024-S
                                                                                                                             TMD-3024-S
                                                                                                              Threaded
                                                                                                            spigots option
                                                                                                               for TMB
w w w. a rc o f a b. c o m
                                                                                             TMB Series
                                                                                             Main chords:     2.0" OD x 0.188"
                                                                                                                                       10 / 2010   T-50
           Mother Grid Series
                    3024 HEAVY DUTY TRUSS SPIGOTED                                                                      TMB-3024-S
                                                                                                                        TMD-3024-S
                             ALLOWABLE
                                     LOAD DATA
                                                 Uniformly distributed load                                   Concentrated load
T-51   10 / 2010
           Mother Grid Series
              3024 HEAVY DUTY TRUSS SPIGOTED                                                    TMB-3024-S
                                                                                                TMD-3024-S
w w w. a rc o f a b. c o m
                                                                                                       10 / 2010   T-52
                             Mother Grid Seismic Series
                                          3024 HEAVY DUTY TRUSS SPIGOTED WITH WHEELS                     TME-3024-SSW
w w w. a rc o f a b. c o m
                                                                                 TME Series
                                                       120’’ (304.8 cm)          Main chords:   2.0" OD x 0.250"
                                                              Plan
                                                                                 Diagonals:     1.5" OD x 0.125"
          30” (76,4 cm)
1.0" OD x 0.125"
                                                                                                                        10 / 2010   T-53
           Mother Grid Seismic Series
                    3024 HEAVY DUTY TRUSS SPIGOTED WITH WHEELS                                                               TME-3024-SSW
                             ALLOWABLE
                                      LOAD DATA
                                             Uniformly distributed load                                           Concentrated load
                                                                      TME-3024-SSW
                                                                       Main chords : 2 ,0" OD x 0,25”
                                                                        Diagonals : 1,5" OD x 0,125"
                                                                                    1,0" OD x 0,125"
                                     Description                   Item                        Weight lb (kg)
                                   10’ - 30” x 24”         TME-3024-120SSW                          162    (73.5)
T-54   10 / 2010
                            Channel Series
                                          3024 HEAVY DUTY TRUSS SPIGOTED                                                                         TCB-3024-S
                                                                                                                                                 TCD-3024-S
w w w. a rc o f a b. c o m
                                                                                                                      TCB Series
                                                                                                                      Main chords:   2.0" OD x 0.188"
1.0" OD x 0.125"
                                                                                                                                                             10 / 2010   T-55
         Channel Series
                   3024 HEAVY DUTY TRUSS SPIGOTED                                                                       TCB-3024-S
                                                                                                                        TCD-3024-S
                         ALLOWABLE
                                  LOAD DATA
                                            Uniformly distributed load                                     Concentrated load
       Notes             s Data  presented in this chart apply to trusses built after January 2002.
                         s Trusses must be loaded symetrically on each side.
                         s All loads must be applied at, or as close as possible to, node points (see section General).
                         s Deflexions are based on the rigidity of the trusses and do not include possible movement
                           between trusses due to attachment tolerance.
                         s Data are valid for inside use only.
                         s Data are only valid for static loads and spans with two supporting points (span must be supported at each end).
                           If dynamic loads or more supporting points are applied, contact a professional engineer or Arcofab.
T-56   10 / 2010
                            Mother Grid Series
                                         3624 HEAVY DUTY TRUSS SPIGOTED                                    TMF-3624-S
w w w. a rc o f a b. c o m
                                                                                TMF Series
                                                                                Main chords:   3.0" OD x 0.250"
                                                      120’’ (304.8 cm)
                                                              Plan
                                                                                Diagonals:     1.66" OD x 0.140"
                                                                                                                       10 / 2010   T-57
          Mother Grid Series
                   3624 HEAVY DUTY TRUSS SPIGOTED                                                                            TMF-3624-S
                            ALLOWABLE
                                     LOAD DATA
                                            Uniformly distributed load                                           Concentrated load
       Notes                s Data  presented in this chart apply to trusses built after January 2002.
                            s Trusses must be loaded symmetrically on each side.
                            s All loads must be applied at, or as close as possible to, node points (see section General).
                            s Deflexions are based on the rigidity of the trusses and do not include possible movement
                              between trusses due to attachment tolerance.
                            s Data are valid for inside use only.
                            s Data are only valid for static loads and spans with two supporting points (span must be supported at each end).
                              If dynamic loads or more supporting points are applied, contact a professional engineer or Arcofab.
                                                                          TMF-3624-S
                                                                    Main chords : 3.0" OD x 0.25"
                                                                    Diagonals : 1.66" OD x 0.140"
T-58   10 / 2010
                             Pre-Rigged Series
                                         3630 HEAVY DUTY TRUSS SPIGOTED WITH WHEELS                       TPB-3630-SW
w w w. a rc o f a b. c o m
                                                                                                                       10 / 2010   T-59
           Pre-Rigged Series
                    3630 HEAVY DUTY TRUSS SPIGOTED WITH WHEELS                                                           TPB-3630-SW
                             ALLOWABLE
                                     LOAD DATA
                                             Uniformly distributed load                                       Concentrated load
       Notes                 s Data  presented in the chart apply to trusses built after January 2002
                             s Trusses must be loaded symmetrically on each side
                             s All loads must be applied at, or as close as possible to, node points (see General Section )
                               Exception for the load on pre-rigged tube (see below)
                             s Deflexions are based on the rigidity of the trusses and do not include possible movement between trusses
                               due to attachment tolerance
                             s Data are valid for inside use only.
                             s Data are only valid for static loads and spans with two supporting points (span must be supported at each end).
If dynamic loads or more supporting points are applied, contact a professional engineer or Arcofab.
                                                                           TPB-3630-S
                                                                      Main chords : 2.0" OD x 0.188"
                                                                       Diagonals : 1.5" OD x 0.125"
T-60   10 / 2010
                            Tripod Series
                                          22 TRIANGULAR FOLDING TRUSS MEDIUM CAPACITY WITH CONNECTION ROD TDB-22FH-R
                                                                                                                    TDD-22FH-R
w w w. a rc o f a b. c o m
                                                                                       TDB Series
                                                                                       Main chords: 2.0" OD x 0.188"
                                                                                                                               10 / 2010   T-61
           Tripod Series                                                                                                     TDB-22FH-R
                    22 TRIANGULAR FOLDING TRUSS MEDIUM CAPACITY WITH CONNECTION ROD
                                                                                                                             TDD-22FH-R
                             ALLOWABLE
                                     LOAD DATA
                                              Uniformly distributed load                                    Concentrated load
       Notes                 s  Data presented in this chart apply to trusses built after January 2002.
                             s  Trusses must be loaded symmetrically on each side.
                             s All loads must be applied at, or as close as possible to, node points (see General Section).
                             s Deflexions are based on the rigidity of the trusses and do not include
                                possible movement between trusses due to attachment tolerance.
                             s Data are valid for inside use only.
                             s Data are only valid for static loads and spans with two supporting points (span must be supported at each end).
                               If dynamic loads or more supporting points are applied, contact a professional engineer or Arcofab.
T-62   10 / 2010
                             Trussformer Series
                                            3036 TRANSFORMER TRUSS SPIGOTED                                        TFB-3036-S
                                                                                                                   TFD-3036-S
w w w. a rc o f a b. c o m
                                                                                      TFB Series
                                                                                      Main chords: 2.0" OD x 0.188"
                                                                                                                              10 / 2010   T-63
           Trussformer Series                                                                                        TFB-3036-S
              3036 TRANSFORMER TRUSS SPIGOTED
                                                                                                                     TFD-3036-S
                   ALLOWABLE
                            LOAD DATA
                                                     Uniformly distributed load
       Notes       s  Data presented in this chart apply to trusses built after January 2002.
                   s  Trusses must be loaded symmetrically on each side.
                   s All loads must be applied at, or as close as possible to, node points (see General Section).
                   s Deflexions are based on the rigidity of the trusses and do not include
                      possible movement between trusses due to attachment tolerance.
                   s Data are valid for inside use only.
                   s Data are only valid for static loads and spans with two supporting points (span must be supported at each end).
                     If dynamic loads or more supporting points are applied, contact a professional engineer or Arcofab.
T-64   10 / 2010
               Custom
                   SCOREBOARD
w w w. a rc o f a b. c o m
                             Each of the scoreboards manufactured by ARCOFAB has its own technical characteristics.
                             Do not hesitate to contact us for specific information on any of these products
                             or for help in the design and manufacturing of any custom-made product that you might require.
                                                                                                                      10 / 2010   C-1
                  Custom
                      SPECIAL WIDE-RANGE BOOTH
w w w. a rc o f a b. c o m
                             Each of the special wide-range booth manufactured by ARCOFAB has its own technical
                             characteristics. Do not hesitate to contact us for specific information on any of these products
                             or for help in the design and manufacturing of any custom-made product that you might require.
C-2   10 / 2010
               Custom
                   BOOTH
w w w. a rc o f a b. c o m
                             Commercial show booths made to your most precise specifications are an example
                             of the custom-made products designed and manufactured by ARCOFAB.
                                                                                                              10 / 2010   C-3
                  Custom
                      CIRCULAR TRUSS
w w w. a rc o f a b. c o m
                                         Each of the circular trusses manufactured by ARCOFAB has its own technical
                                         characteristics. Do not hesitate to contact us for specific information on any of
                                         these products or for help in the design and manufacturing of any
                                         custom-made product that you might require.
C-4   10 / 2010
               Custom
                   BATTENS
w w w. a rc o f a b. c o m
                                                                                                                               C-5
                                                                                                                   10 / 2010
                  Custom
                      GRID MGM LAS VEGAS
w w w. a rc o f a b. c o m
                                                                                                   “Cirque du Soleil”
                                                                                                    MGM Las Vegas
C-6   10 / 2010
                  Custom
                      SUPPORT SYSTEM FOR LED
w w w. a rc o f a b. c o m
                             Each of the support system for LED manufactured by ARCOFAB has its own technical characteristics.
                             Do not hesitate to contact us for specific information on any of these products or for help
                             in the design and manufacturing of any custom-made product that you might require.
C-7   10 / 2010
                    Custom
                      ROLLER BLOCK FOR 3020 AND 2020 CONNECTIONS
w w w. a rc o f a b. c o m
                                                                            20,5” (52,1 cm)
                                         Each of the roller block manufactured by ARCOFAB has its own technical characteristics.
                                         Do not hesitate to contact us for specific information on any of these products or for help
                                         in the design and manufacturing of any custom-made product that you might require.
C-8   10 / 2010
                  Custom
                      OCTOCUBE
w w w. a rc o f a b. c o m
                                     Each of the Octocube manufactured by ARCOFAB has its own technical characteristics.
                                     Do not hesitate to contact us for specific information on any of these products or for help
                                     in the design and manufacturing of any custom-made product that you might require.
C-9   10 / 2010
                   Support system
                      DELAY TOWER
w w w. a rc o f a b. c o m
                                                                             HEIGHT AVAILABLE
                                                                           25 to 50’ / 7.6 à 15.2 m
                                                                           LOAD AVAILABLE
                                                                  1 000 to 5 000 lb / 450 to 2 300 kg
SS-2   10 / 2010
               SUPPORT SYSTEM
                  ROOF SYSTEM
w w w. a rc o f a b. c o m
                                 Each of the roof systems manufactured by ARCOFAB has its own technical
                                 characteristics. Do not hesitate to contact us for specific information on any
                                 of these products or for help in the design and manufacturing of any custom-made
                                 product that you might require.
                                                                                                                  10 / 2010   SS-1
                  Support System                                                                                                 Support System
                        ROOF SYSTEM RS105 x 40 / 30T                                                                                 ROOF SYSTEM RS105 x 40 / 30T
                                                                                                                                                                                                          40’
                                                                                                                                                                                                       (12.2 m)
                                                                                                                                                                                                    20’-10”
                                                                                                                                                                                                    (6.4 m)
w w w. a rc o f a b. c o m
                                                                                                                                                                           Plan
                                                                                                                                                                                                         40’-5”
                                                                                                                                                                                                        (12.3 m)
                                                                                                   CAPACITY
                                                                                             60 000 lb / 27 000 kg
   See picture inside                                                                                                                                                    60’ (18.3 m)
                                                                                                                                                                                           22’-6”
                                                                                                                                                                                          (6.9 m)
                        Each of the roof systems manufactured by ARCOFAB has its own technical characteristics.                                                          105’ (32 m)
                        Do not hesitate to contact us for specific information on any of these products or for help                 End view                              Elevation
                        in the design and manufacturing of any custom-made product that you might require.
                                 1 888 515-1704 / 450 515-1705 / sales@arcofab.com                                                             1 888 515-1704 / 450 515-1705 / sales@arcofab.com
                                                                                                              10 / 2010   SS-3
              Support System
                     ROOF SYSTEM RS105 x 40 / 30T
w w w. a rc o f a b. c o m
           CAPACITY
60 000 lb / 27 000 kg