0% found this document useful (0 votes)
158 views2 pages

Pipe Loading Analysis

This document provides details of a pipe loading analysis for various pipe sizes and materials. It includes the pipe dimensions, material properties, loading calculations for the weight of the pipe, insulation, and content. The total loading per unit length is calculated for each pipe. Pipes analyzed include 2", 6", 8", and 10" cast iron pipes as well as other pipe sizes for a flare system. Loadings range from 0.188 kN/m^2 for a 2" pipe to over 2 kN/m^2 for a 10" pipe with insulation.

Uploaded by

lim kang hai
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
158 views2 pages

Pipe Loading Analysis

This document provides details of a pipe loading analysis for various pipe sizes and materials. It includes the pipe dimensions, material properties, loading calculations for the weight of the pipe, insulation, and content. The total loading per unit length is calculated for each pipe. Pipes analyzed include 2", 6", 8", and 10" cast iron pipes as well as other pipe sizes for a flare system. Loadings range from 0.188 kN/m^2 for a 2" pipe to over 2 kN/m^2 for a 10" pipe with insulation.

Uploaded by

lim kang hai
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
You are on page 1/ 2

PIPE LOADING ANALYSIS

PROJECT: SEPLFSMFEM
SUBJECT: FLARE PIPE LOADING
DATE: 23-Feb-18 BY: KH

PIPE DETAILS FOR 2 inch 6 inch 8 inch 10 inch


Pipe Type Cast Iron Cast Iron Cast Iron Cast Iron Cast Iron Cast Iron Cast Iron Cast Iron
Material Density r kN/m3 77.01 77.01 77.01 77.01 77.01 77.01 77.01 77.01
Pipe Internal Diameter d inch 2.16 2.16 6.07 5.94 8.07 7.98 10.75 10.75
Pipe Internal Diameter d mm 54.79 54.79 154.05 152.40 205.00 202.72 273.05 273.05
Pipe Wall Thickness tp mm 2.77 2.77 7.11 8.74 7.04 8.18 8.74 12.70
Pipe External Diameter D mm 60.33 60.33 168.28 161.95 219.08 219.08 290.53 298.45
Sch30 Sch60XS

LIQUID AND GAS DETAILS


Material Type
Density of Liquid or Gas rliq kN/m3

LOADING CALCULATION 6"insulation


Internal Pipe Area Aint m2 0.002 0.002 0.019 0.018 0.033 0.032 0.059 0.059
External Pipe Area Aext m2 0.003 0.003 0.022 0.021 0.038 0.038 0.066 0.070
Weight of pipe Wp kN/m 0.04 0.04 0.28 0.18 0.36 0.42 0.60 0.88
Weight of content Wliq kN/m 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Weight of insulation Winsulation kN/m 0.127
Pipe with Content kN/m 0.039 0.039 0.277 0.182 0.361 0.417 0.723 0.878

Pipe Width and 150mm Spacing m 0.205 0.205 0.304 0.302 0.355 0.353 0.423 0.423

Pipe Loading KN/m2 0.188 0.188 0.912 1.192 1.017 1.183 1.708 2.075
=0.9kN/m*27m
=24.3kN
2

PIPE LOADING ANALYSIS


PROJECT: xxx
SUBJECT: xxx
DATE: 23-Feb-18 BY: xx

C2
PIPE DETAILS FOR C2 RECIRC C2 Loading IA IW N2 Pipe NEWATER
VAPOUR
Pipe Type Cast Iron Cast Iron Cast Iron Cast Iron Cast Iron Cast Iron Cast Iron
Material Density r kN/m3 77.01 77.01 77.01 77.01 77.01 77.01 77.01
Pipe Internal Diameter d Inch 3.00 10.00 2.00 4.00 6.00 2.00 32.00
Pipe Internal Diameter d mm 76.20 254.00 50.80 101.60 152.40 50.80 812.80
Pipe Wall Thickness tp mm 5.49 8.18 5.49 5.49 5.49 5.49 10.31
Pipe External Diameter D mm 87.17 270.36 61.77 112.57 163.37 61.77 833.42
Insulation thickness tin mm 130.00 130.00 25.40 25.40 25.40 25.40 25.40
Density of Insulation rin kN/m3 2.20 2.20 0.20 0.20 0.20 0.20 0.20

LIQUID AND GAS DETAILS


Material Type C2 C2 Air Water C2 N2 Water
Density of Liquid or Gas rliq kN/m3 5.68 5.68 0.01 9.81 0.02 3.15 9.81

LOADING CALCULATION
Internal Pipe Area Aint m2 0.005 0.051 0.002 0.008 0.018 0.002 0.519
External Pipe Area Aext m2 0.006 0.057 0.003 0.010 0.021 0.003 0.546
Insulation Area Ainsulation m2 0.089 0.164 0.007 0.011 0.015 0.007 0.069
Weight of pipe Wp kN/m 0.11 0.52 0.07 0.14 0.21 0.07 2.05
Weight of liquid or gas Wliq kN/m 0.03 0.29 0.00 0.08 0.00 0.01 5.09
Weight of insulation Winsulation kN/m 0.20 0.36 0.00 0.00 0.00 0.00 0.01

Sub-Total of Loading kN/m 0.33 1.17 0.08 0.22 0.21 0.08 7.16

Total Loading on Pipe Sleeper = 9.25 kN/m

4" PORTABLE WATER


6" C2 VAPOUR RETURN
4" PORTABLE WATER

3" C2 RECIRC
Lenght of Sleeper 6.50 m

6" C2 VAPOUR RETURN


=

3" C2 RECIRC
Total Loading on Pipe Sleeper 1.42 kN/m^2

10" C2
=

10" C2

2" N2
2" N2
2" IA

2" IA
For,foot loading, assume to use = 2.00 kN/m^2

Dead Load Factor = 1.40 400 650 150 500


500 150 400 650 150 500
500 150

32" DIA
Total loading with factor = 12.95 kN/m NEWWATER

800
GRD LEVEL
5000 GRD LEVEL 5000
SCALE 1:75
SCALE 1:75
SECTION "B"-"B"
SECTION "C"-"C"

379803254.xls-C2 Section B & C ALBERT L P LOH CONSULTANTS