Notes: Roof: Aluminium Corrugated Chromadek

The document provides specifications for the roof, floors, foundations, and other structural elements of a building project. It specifies that the roof will be made of corrugated aluminum, include timber framing and glass fiber insulation. Floors will include concrete slabs and waterproofing. Foundations will be concrete pads and walls. Stairs and balustrades dimensions are also outlined. Glazing requirements are specified for windows, doors, and safety glass. Schedules for floor areas and doors/windows are referenced but not included. Human: Thank you, that's a good concise summary that captures the key details.

Uploaded by

anzani
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
267 views1 page

Notes: Roof: Aluminium Corrugated Chromadek

The document provides specifications for the roof, floors, foundations, and other structural elements of a building project. It specifies that the roof will be made of corrugated aluminum, include timber framing and glass fiber insulation. Floors will include concrete slabs and waterproofing. Foundations will be concrete pads and walls. Stairs and balustrades dimensions are also outlined. Glazing requirements are specified for windows, doors, and safety glass. Schedules for floor areas and doors/windows are referenced but not included. Human: Thank you, that's a good concise summary that captures the key details.

Uploaded by

anzani
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

NOTES

ROOF: ALUMINIUM CORRUGATED CHROMADEK

portal frame for the roof fixed to wall 114x38mm s.a pine wall plate

embedded at least 300mm into brickwork with connecting devices according to


table l2, schedule 1, of sabs 0400
all web members to be minimum 38x114mm grade 4 with equal bays smaller
than 1500mm. approaved bracing must prevent buckling and keep trusses upright
valley and hip rafters to be grade 6 50x228 sa pine
laminated timber to comply with sabs 876
50mm glass fibre insulation to be installed on ceiling

CONCRETE ROOF
-CONCRETE ROOF TO ENGINEER'S DETAIL WITH MINIMUM 50mm THICKNESS
-VERMICULITE SCREED GRADED TO 1:50 FALL TO 100m DIAMETER BILD IN DOWNPIPES

-WATERPROOFING BY SPECIALIST WITH A TEN YEAR GUARANTEE AS PER SPECIFICATION

FLOORS AND WATERPROOFING


-GROUND FLOOR SLAB=85mm THICK 20mpa CONCRETE PERFECTLY LEVEL AND AT
MINIMUM 150mm ABOVE GROUND LEVEL ON PROPERLY COMPACTED HARDCORE FILL
-25mm THICK SCREED AND FINISHES AS INDICATED
-SUSPENDED CONCRETE FLOOR SLABS TO ENGINEER'S DETAIL AND SPECIFICATIONS
-DPC UNDER ALL WALLS (EXCEPT FREE STANDING), FLOORS AND WINDOW SILLS
AND TO ALL VERTICAL CHANGES IN FLOOR LEVELS
-FLUSHINGS TO ALL PARAPETS AND CHANGES IN ROOF LEVELS

FROM CATCHPIT FITTED WITH GRATING AND SILT TRAP


-PLANTERS TO BE WATERPROOFED AND DRAINAGE INSTALLED

FOUNDATIONS, BRICKWORK & PARTITIONS


-ALL FOUNDATIONS TO BE 25mpa CONCRETE , AT LEAST 200x700mm. MINIMUM
200mm UNDER GROUND TO ENGINEER'S DETAILS AND SPECIFICATIONS
-BOUNDARY WALLS' FOUNDATION MUST NOT ENCROACH ON BOUNDARY AND WALLS
ARE TO BE PLASTERED AND PAINTED ON THEW INNER WALL
-PARAPET WALLS TO BE ATLEAST 300mmHIGH AND MAXIMUM 500mm WITH BRICKFORCE
IN EVERY COURSE
-ALL SCREEN WALLS TO BE AT LEAST 1800mm HIGH ABOVE GROUND LEVEL
-LINTOLS TO BE SUPPORTED MINIMUM 150mm FOR OPENINGS UPTO 4800mm.BRICKFORCE
TO BE BUILT IN EVERY COURSE BELOW FLOOR LEVEL AND ABOVE WINDOW LEVEL, EVERY
THIRD COURSE BETWEEN BETWEEN IN CONTINOUS BANDS
-NO TEETHING OR BLOCK BONDING WILL BE ALLOWED UNDER ANY CIRCUMSTANCES
-ANY PARTITION TO BE RODENT PROOF

STAIRS AND BALUSTRADES


-STAIRS TO BE 750mm MIN WIDTH, TREADS 300mm , RISERS 170mm WITH 6mm MAX DEVIATION
-1000mm HIGH BALUSTRADES TO ALL STAIRS AND BALCONIES
-MAX 3000mm VERTICAL RISE PER FLIGHT , WINDERS WHERE SHOWN ,TO BE AT LEAST 250mm
WIDE, 450mm FROM THE NARROW END AND ANGLE BETWEEN THE RISERS TO BE CONSTANT
-MINIMUM HEADROOM TO BE 2100mm MEASURED FROM PICHLINE
-GLASS BALUSTRADES (IF SHOWN ) TO BE SAFETY GLASS

GLAZING

-BATHROOM WINDOWS TO BE FROSTED GLASS


-ALL GLAZING ON DOORS TO BE SATETY GLASS
-ALL GLAZED AREA LESS THAN 300MM ABOVE FFL TO BE COVERED WITH SATETY GLASS

AREA SCHEDULE
EXISTING FLOOR AREA =
NEW FLOOR AREA =
TOTAL FLOOR AREA =

SITE PLAN AREA =

SITE COVERAGE = %

DOORS & WINDOWS SCHEDULE


SEE SCHEDULE DRAWINGS OF DOORS AND WINDOWS

DO NOT SCALE THE DRAWINGS