FERROXCUBE
DATA SHEET
  3C94
  Material specification
Supersedes data of September 2004       2008 Sep 01
Ferroxcube
     Material specification                                                                                                                 3C94
3C94 SPECIFICATIONS
 A low frequency power material for use in power and
 general purpose transformers at frequencies up to                                    104
                                                                                                                                         CBW236
 0.3 MHz.                                                                    handbook, halfpage                                          3C94
                                                                                   µ's ,µ''s
SYMBOL               CONDITIONS             VALUE             UNIT
                                                                                               µ's
µi               25 °C; ≤10 kHz;     2300 ±20%                                         103
                 0.25 mT
µa               100 °C; 25 kHz;     5500 ±25%                                                                                 µ''s
                 200 mT
B                25 °C; 10 kHz;      ≈ 470                    mT
                                                                                       102
                 1200 A/m
                 100 °C; 10 kHz;     ≈ 380
                 1200 A/m
PV               100 °C; 100 kHz;    ≈ 50                     kW/m 3
                 100 mT                                                                 10
                                                                                         10−1               1             10                    102
                 100 °C; 100 kHz;    ≈ 350                                                                                        f (MHz)
                 200 mT
ρ                DC, 25 °C           ≈5                       Ωm
TC                                   ≥ 220                    °C
density                              ≈ 4800                   kg/m3                            Fig.1     Complex permeability as
                                                                                                         a function of frequency.
                                                     CBW237                                                                              CBW238
       10000                                                                          500
handbook, halfpage                                   3C94                       handbook, halfpage               25 °C
                                                                                                                                          3C94
                                                                                    B                           100 °C
         µi
                                                                                   (mT)
        8000                                                                          400
        6000                                                                          300
        4000                                                                          200
        2000                                                                          100
              0                                                                          0
              −50           50           150             250                              −25        0     25        50        150              250
                                               T (°C)                                                                                 H (A/m)
                Fig.2    Initial permeability as a
                         function of temperature.                                                    Fig.3 Typical B-H loops.
2008 Sep 01                                                            121
Ferroxcube
  Material specification                                                                                                                          3C94
                                                               CBW239                                                                        CBW240
      8000                                                                                 104
handbook, halfpage                  25 °C                                          handbook, halfpage                                        3C94
                                   100 °C                        3C94
       µa
                                                                                           µ rev
      6000
                                                                                           103
      4000
                                                                                           102
      2000
            0                                                                                 10
                0           100         200     300                    400                          1             10           102                    103
                                                          ^
                                                          B (mT)                                                                      H (A/m)
                    Fig.4   Amplitude permeability as a                                       Fig.5      Reversible permeability as a
                            function of peak flux density.                                               function of magnetic field strength.
                                                                 CBW241                                                                      CBW242
       104                                                                                    800
handbook, halfpage                                              3C94                handbook, halfpage                                     3C94
                 T = 100 °C
                                                                                         Pv
      Pv                                                                                                                                          ^
                                                                                      (kW/m3)                                            f    B
   (kW/m3)
                                                         kH z
                                                        kHz
                                                                                                                                       (kHz) (mT)
                                                                                              600
                                                     200
                                                    100
        103
                                                                                                                                       100    200
                                                                 kHz
                                                                                              400
                                                              25
        102
                                                                                                                                       200    100
                                                                                              200
                                                                                                                                       100    100
                                                                                                                                        25    200
           10                                                                                   0
                1                 10          102     ^                103                          0        40        80            120
                                                    B (mT)                                                                  T (°C)
                                                                                           Fig.7        Specific power loss for several
    Fig.6           Specific power loss as a function of peak                                           frequency/flux density combinations
                    flux density with frequency as a parameter.                                         as a function of temperature.
2008 Sep 01                                                                  122
Ferroxcube
  Material specification                                                                                         3C94
DATA SHEET STATUS DEFINITIONS
     DATA SHEET              PRODUCT
                                                                            DEFINITIONS
       STATUS                 STATUS
Preliminary                Development      This data sheet contains preliminary data. Ferroxcube reserves the right to
specification                               make changes at any time without notice in order to improve design and
                                            supply the best possible product.
Product specification      Production       This data sheet contains final specifications. Ferroxcube reserves the right
                                            to make changes at any time without notice in order to improve design and
                                            supply the best possible product.
DISCLAIMER
Life support applications  These products are not designed for use in life support appliances, devices, or systems
where malfunction of these products can reasonably be expected to result in personal injury. Ferroxcube customers
using or selling these products for use in such applications do so at their own risk and agree to fully indemnify Ferroxcube
for any damages resulting from such application.
PRODUCT STATUS DEFINITIONS
  STATUS        INDICATION                                             DEFINITION
                                 These are products that have been made as development samples for the purposes of
Prototype                        technical evaluation only. The data for these types is provisional and is subject to
                                 change.
Design-in                        These products are recommended for new designs.
                                 These products are recommended for use in current designs and are available via our
Preferred
                                 sales channels.
                                 These products are not recommended for new designs and may not be available
Support
                                 through all of our sales channels. Customers are advised to check for availability.
2008 Sep 01                                                 123