Construction details
4 5       6     7             8            3.3       Architectural details
                                                                                                   Flat roof junction
                                             3
                                                                                                   3.3.1   Concrete construction
                                                                                                   3.3.2   Timber construction
                                                            12                                     3.3.3   Steel construction, penetration
                                             2
                                                                  11                               3.3.4   Steel construction with fascia plate and
                                                                                           9
                                                                                                           sunshade
                                             1
                                                                  13                               Vertical sections
                                                                                                   scale 1:5
                                                                                                   Typical details of various flat roof junctions with
                                                                                                   different architectural and constructional char-
                                                         11                                        acteristics plus different materials are shown on
                                                                                                   this and the next page.
                                                                                                   Fig. 3.3.1. The primary structure here is rein-
                                                                                                   forced concrete. The edge of the slab and the
                                                                                                   overlying roof construction are clad with a steel
                                                                                                   plate attached to the concrete. The posts are
                                                            14                                     fixed to angles welded to this plate. The con-
                                                                                                   nection of the upper facade rail to the edge
                                                                                                   plate is impervious to air and vapour diffusion.
                                                                                                   The clearance between glazing and plate to
                                                                                                   the front edge of roof slab should be wide
                                                                                                   enough to allow cleaning of the glass. Heat
                                                                                                   reflected back from the edge of the slab could
                                                                                                   lead to stresses in the glass caused by varying
                                                                                           3.3.1   heating effects. A stationary layer of air can
                                                  4 5   8                                          lead to condensation occurring. Suitable venti-
1     Double glazing                                                                               lation at the parapet, e.g. by including ventila-
2     Aluminium facade rail                                                                        tion louvres, should be considered at the plan-
3     Plastic spacer block
4     Sheet metal cleat                                                                            ning stage.
5     Vapour barrier (EPDM sheeting)                                                               Fig. 3.3.2. The primary structure here is an
6     EPDM pad                                                                                     insulated timber frame; timber panels form the
7     Thermal insulation                                                                           fascia. The junction with the facade is achieved
                                                                       9
8     Anodised aluminium sheet
9     Roof construction:
                                                                                                   in two ways: in the plane of the glass by a
      chippings                                                                                    clamped plastic block, and in the structural
      waterproofing                                                                                plane by an insulated aluminium hollow section
      thermal insulation                                                                           with thermal break. The connection must be
      vapour barrier                                                                               able to accommodate movements in the facade
10    Glulam beam
11    Steel angle                                                                                  as well as deformation of the primary structure
12    Vapour barrier                                                                               caused by imposed loads, thermal expansion
13    Sheet steel                                                                                  etc. It must also remain impervious to air and
14    Bolt in elongated hole                 18                        10
                                                                                                   vapour diffusion, and must be thermally insu-
15    Permanently elastic seal
                                                                                                   lated.
16    Aluminium section, insulated,
      with thermal break                      7                                                    Fig. 3.3.3. The primary structure here is steel.
17    Movement joint                                                                               The facade posts are fixed to the main struc-
18    Plywood, with waterproof adhesive                                                            ture via steel angles. The steel beams penetrat-
19    Joist hanger                            5
                                                                                                   ing the facade are thermal bridges. Condensa-
20    Aluminium angle bolted to supporting
      construction                                                                                 tion may occur and should be drained away in
21    Fabric sunshade                                                                              a controlled manner (e.g. condensation chan-
22    Steel bracket                           3                             15   19       12       nel). The joint between external skin and beam
23    Insulated facade panel                                                16                     must be able to accommodate the various
24    Cast-in slotted channel
                                                                                                   movements of the facade and loadbearing
25    Special perforated steel beam
26    Stainless steel plate, bolted on                                                             structure (especially thermal expansion and
                                              1               2
27    Steel tube                                                                                   wind loads). It must also be impervious to air
28    Steel trapezoidal profile sheeting                                                           and vapour diffusion. It is normally covered by
                                                                                                   a stainless steel sleeve fitted to the outside.
                                                                                           3.3.2
184