ICV008H7O7
Full DC 1-Way Cassette Indoor Unit
Performance: Unit Data:
Cooling Mode.
Nominal Capacity (Btu/h) 7,500 Refrigerant Type R410a
Power Input (Kw) 0.030 Refrigerant Control EXV
Sound Pressure (H/M/L) dB(A) 36/32/28
Heating Mode.
Net Weight (Kg) main body 20
Nominal Capacity (Btu/h) 8,500
panel 4.2
Power Input (Kw) 0.030
Gross Weight (Kg) main body 27
Rated cooling capacity test condition: Indoor 27° C DB / 19° C WB
Outdoor 35° C DB panel 6
Rated heating capacity test condition: Indoor 20° C DB
Outdoor 7° C DB/ 6° C WB
Connection pipe length 5m without height drop between units. Airflow volume (H/M/L) (CFM) 355/295/265
Electrical:
Power Supply (V/Ø/Hz) 220~240/1/50 The total capacity of connected indoor units must be in the range of 50% ~ 135%
of the outdoor unit capacity.
208~230/1/60 The above parameters are tested based on the standard connection pipe length.
In the actual project, the parameters should be corrected referring to the capacity
Minimum Circuit Ampacity (A) 0.25 Correction for the long connection pipe of units.
Maximum Overcurrent Protection(A) 6
Piping:
Drain pipe size (mm) φ25 X 2.5
External diameter X wall thickness
Gas pipe size (mm) φ9.52
Liquid pipe size (mm) φ6.35