Coating Thickness Gages For: ALL Metal Substrates
Coating Thickness Gages For: ALL Metal Substrates
ORDERING
GUIDE
Standard F1 FS1 FXS1* FRS1 F0S1 F45S1 F90S1 FT1 FTS1 FHXS1** FKS1 FLS1
Coating Thickness Gages for
FERROUS
PROBES
Advanced F3 FS3 FXS3* FRS3 FOS3 F45S3 F9OS3 FT3 FTS3 FHXS3** FKS3 FLS3 ALL Metal Substrates
Standard N1 NS1 NRS1 NAS1 N0S1 N45S1 N90S1 NKS1
NON-FERROUS
PROBES N3 NS3 NRS3 NAS3 NOS3 N45S3 N9OS3 NKS3
Advanced
0–60mils Ferrous: 0–45mils and 0–1150µm 0–250mils 0–400mils 0–500mils 0–1.5inches 0–2.5inches
Range
0–1500µm Non-Ferrous: 0–25mils and 0–625µm 0–6mm 0–10,000µm 0–13mm 0–38mm 0–63.5mm
+(0.05 mil + 1%) 0-2 mils + (0.02 mil + 1%) 0-4 mils + (0.5 mil + 1%) 0-100 mils
+(0.1 mil + 1%) >2 mils +(0.1 mil + 3%) >4 mils + (0.5 mil + 3%) >100 mils +(0.1 mil + 3%) +
(1 mil + 3%) + (0.01 in. + 3%)
Accuracy ‡
+(1 µm + 1%) 0-50 µm +
(0.5 µm + 1%) 0-100 µm +(0.01 mm + 1%) 0-2.5 mm +(2 µm + 3%) +(0.02 mm + 3%) +(0.2 mm + 3%)
+(2 µm + 1%) >50 µm +(2 µm + 3%) >100 µm +(0.01 mm + 3%) >2.5 mm
Ferrous probes measure non-magnetic coatings on ferrous metals. Non-Ferrous probes measure non-conductive coatings on non-ferrous metals. *FXS Xtreme probe with Alumina wear face. Ideal for rough
surfaces. **FHXS Xtreme probe with Alumina wear face and braided cable measures non-conductive coatings on steel. Ideal for rough or hot surfaces up to 250˚ C (500˚ F). ^FNDS probes for full accuracy
information see website. †FNGS probe measures non-conductive coatings on all metals. ‡ Accuracies are stated as a fixed value plus a percentage of the gage’s actual reading.
Quick Release
Adapter for 0˚ Probe
Includes protective
rubber holster
Side View
DeFelsko Corporation • 800 Proctor Ave. • Ogdensburg, New York 13669-2205 USA
Toll Free 1-800-448-3835 • Tel: +1-315-393-4450 • Fax: +1-315-393-8471 WiFi Compatible
t echs ale@de fe lsko .com • www. defelsko.c om
®
Thick
90 ˚ 45 ˚
For measuring paint, powder, etc. ...and for measuring galvanizing, plating, 0˚ Regular FNDS Probe measures individual layer thicknesses FHXS Probe with Alumina wear face and Flip Display enables right-side-up viewing Microprobe series for small parts
on all metals... anodizing and more. of zinc and paint in a duplex coating system braided cable for hot or rough surfaces and hard-to-reach areas
®
Thick
90 ˚ 45 ˚
For measuring paint, powder, etc. ...and for measuring galvanizing, plating, 0˚ Regular FNDS Probe measures individual layer thicknesses FHXS Probe with Alumina wear face and Flip Display enables right-side-up viewing Microprobe series for small parts
on all metals... anodizing and more. of zinc and paint in a duplex coating system braided cable for hot or rough surfaces and hard-to-reach areas
90° Ideal for Microprobes – Integral and Cabled
Our most popular Ideal for
Regular duplex Our smallest probes probes for thick protective
Integral and Cabled anodized
probe for coating for small parts coatings; epoxy, rubber, intumescent
probe models aluminum
tight spots systems or hard-to-reach areas fireproofing and more
ORDERING
GUIDE
Standard F1 FS1 FXS1* FRS1 F0S1 F45S1 F90S1 FT1 FTS1 FHXS1** FKS1 FLS1
Coating Thickness Gages for
FERROUS
PROBES
Advanced F3 FS3 FXS3* FRS3 FOS3 F45S3 F9OS3 FT3 FTS3 FHXS3** FKS3 FLS3 ALL Metal Substrates
Standard N1 NS1 NRS1 NAS1 N0S1 N45S1 N90S1 NKS1
NON-FERROUS
PROBES N3 NS3 NRS3 NAS3 NOS3 N45S3 N9OS3 NKS3
Advanced
0–60mils Ferrous: 0–45mils and 0–1150µm 0–250mils 0–400mils 0–500mils 0–1.5inches 0–2.5inches
Range
0–1500µm Non-Ferrous: 0–25mils and 0–625µm 0–6mm 0–10,000µm 0–13mm 0–38mm 0–63.5mm
+(0.05 mil + 1%) 0-2 mils + (0.02 mil + 1%) 0-4 mils + (0.5 mil + 1%) 0-100 mils
+(0.1 mil + 1%) >2 mils +(0.1 mil + 3%) >4 mils + (0.5 mil + 3%) >100 mils +(0.1 mil + 3%) +
(1 mil + 3%) + (0.01 in. + 3%)
Accuracy ‡
+(1 µm + 1%) 0-50 µm +
(0.5 µm + 1%) 0-100 µm +(0.01 mm + 1%) 0-2.5 mm +(2 µm + 3%) +(0.02 mm + 3%) +(0.2 mm + 3%)
+(2 µm + 1%) >50 µm +(2 µm + 3%) >100 µm +(0.01 mm + 3%) >2.5 mm
Ferrous probes measure non-magnetic coatings on ferrous metals. Non-Ferrous probes measure non-conductive coatings on non-ferrous metals. *FXS Xtreme probe with Alumina wear face. Ideal for rough
surfaces. **FHXS Xtreme probe with Alumina wear face and braided cable measures non-conductive coatings on steel. Ideal for rough or hot surfaces up to 250˚ C (500˚ F). ^FNDS probes for full accuracy
information see website. †FNGS probe measures non-conductive coatings on all metals. ‡ Accuracies are stated as a fixed value plus a percentage of the gage’s actual reading.
Quick Release
Adapter for 0˚ Probe
Includes protective
rubber holster
Side View
DeFelsko Corporation • 800 Proctor Ave. • Ogdensburg, New York 13669-2205 USA
Toll Free 1-800-448-3835 • Tel: +1-315-393-4450 • Fax: +1-315-393-8471 WiFi Compatible
t echs ale@de fe lsko .com • www. defelsko.c om