GAS / LIQUID SEPARATOR SIZING
K factor Calculation
K factor standard, ft/sec 0.35
Pressure Correction Factor 0.78
Liquid Load Correction Factor 1
Service Factor 0.75
K factor considered, ft/sec 0.20
Separator Size Calculation
Terminal Velocity, ft/s 0.61 Dl 28.45
Cross Sectional Area, ft2 2.00 Dg 2.843
Diameter Calculated, in 19.16 Qg 1.23
Diameter Selected, in 20.00
L/D Ratio Considered 3.6
Height, ft 6
Liquid Levels Selection
Low Liquid Level, in 12
Normal Liquid Level (Botom), in 16 72
Normal Liquid Level (Top), in 24 2.1176470588
High Liquid Level, in 28
Low Low Liquid Level, in 6
High High Liquid Level, in 34
Drainage Time Calculation
Drainage Acc. Volume Assumed, gpm 2
Drainage Time for Normal Op, min 5.44 5.4399872789
Drainage Time for Emergency Op, min 14.96 14.959965017
Retention Time Calcs and Liquid Levels Verification
Retention Time for Normal Op, min 3.63 3.626658186
Holdup Time, min 2.72 2.7199936395
Surge Time, min 1.81 1.813329093
Operator Response Time to ESD, min 2.72 4.0799904592
lb/ft3
lb/ft3
ft3/seg
3.42857143
12590 lb/hr 150778.443 ft3/hr
0.0835 lb/ft3 41.8829009 ft3/seg
ql 3
2.71999364
GAS / LIQUID SEPARATOR SIZING
K factor Calculation
K factor standard, ft/sec 0.35
Pressure Correction Factor 0.95
Liquid Load Correction Factor 1
Service Factor 0.75
K factor considered, ft/sec 0.25
Separator Size Calculation
Terminal Velocity, ft/s 4.94 Dl 32.86
Cross Sectional Area, ft2 8.48 Dg 0.0835
Diameter Calculated, in 39.42 Qg 41.88
Diameter Selected, in 40.00
L/D Ratio Considered 3.0
Height, ft 10
Liquid Levels Selection
Low Liquid Level, in 14
Normal Liquid Level (Botom), in 18
Normal Liquid Level (Top), in 28
High Liquid Level, in 32 120
Low Low Liquid Level, in 8
High High Liquid Level, in 38 3.1578947368
Drainage Time Calculation
Drainage Acc. Volume Assumed, gpm 10
Drainage Time for Normal Op, min 5.44 5.4399872789
Drainage Time for Emergency Op, min 13.06 13.055969469
Retention Time Calcs and Liquid Levels Verification
Retention Time for Normal Op, min 3.63 3.626658186
Holdup Time, min 2.18 2.1759949116
Surge Time, min 1.45 1.4506632744
Operator Response Time to ESD, min 2.18 3.2639923674
lb/ft3
lb/ft3 8.4754083
ft3/seg 3.285 ft
39.42
3.42857143
ql 15
2.17599491
CORRIENTE 1 2 3
DESCRIPCION SALIDA DE BATERIA
DE BATERIA 5058 DE BATERIA 194 194
PARAMETRO UNIDAD
FLUJO VOLUMETRICO MMSCFD 1.573 0.813 2.386
FLUJO MASICO lb/h 3300 1706 5006
PRESION DE OPERACIÓN psig 18.00 13.00 13.00
TEMPERATURA DE OPERACIÓN °F 77.00 77.00 86.15
DENSIDAD @ T Y P DE OPERACIÓN lb/ft3 0.1092 0.0924 0.0909
BALANCE DE MATERIA DE ESTACION DE COMPRESION 191 (EC-191)
4 5 6 7 8 9
SALIDA DE BATERIA ENTRADA A SALIDA DE SCRUBBER
DE BATERIA 205 DE BATERIA 191 DE BATERIA 193 191 SCRUBBER V-100 V-100
2.094 1.307 0.213 1.520 6.000 6.000
4393 2742 446.9 3189 12590 12590
15.00 13.00 15.00 13.00 11.26 10.89
77.00 77.00 77.00 79.45 87.43 88.83
0.0992 0.0924 0.0992 0.0920 0.0849 0.0835
1)
10 11 12 13 14 15
ENTRADA A SUCCION SALIDA DE ENTRADA A SUCCION SALIDA DE ENTRADA A SALIDA DE SCRUBBER
DE COMPRESOR C- DESCARGA DE DE COMPRESOR C- DESCARGA DE SCRUBBER V-200 V-200
100 COMPRESOR C-100 200 COMPRESOR C-200
3.000 3.000 3.000 3.000 6.000 6.000
6295 6295 6295 6295 12590 12590
10.68 799.80 10.68 799.80 798.70 648.70
89.85 129.50 89.85 129.50 120.70 112.20
0.0827 2.7830 0.0827 2.7830 2.8430 2.3150
16
DERIVACION A
INYECCION A POZOS
6.000
12590
648.30
110.50
2.3230