OLYMPIC CABLE COMPANY SDN. BHD.
11KV SINGLE CORE CROSS-LINKED POLYETHYLENE (XLPE) INSULATED, PVC INNER SHEATHED, ALUMINIUM WIRE ARMOURED, PE OVERSHEATHED CABLE
                                                     TECHNICAL DATA
                                                                                                           2
REF   DESCRIPTION                                                UNIT                            630 mm x 1C
 1    Reference standard                                                                      IEC 60502-2:1998
 2    Voltage (Uo / U)                                                  kV                        6.35 / 11
 3    Number of cores                                                                                1
 4    Conductor
      - Material                                                                         Plain Annealed Copper wires
      - Cross sectional area                                           mm2                           630
      - Number of strands                                              Nos.                       Min. 53
      - Conductor shape                                                                       Compacted circular
      - Conductor's outermost lay direction                                                 Right-handed ( Z)
  5   Conductor Screen
      -Material                                                                          Semi-conducting compound
  6   Insulation
      - Material                                                                          Cross-linked Polyethylene
      - Nominal thickness                                               mm                           3.4
  7   Insulation Screen
      -Material                                                                          Semi-conducting compound
      -Method of application                                                                     Extrusion
      -Diameter over insulation screen (Approx.)                        mm                        37.70
  8   Metallic Screen
      -Material                                                                                 Copper Tape
      -Nominal thickness                                                mm                         0.08
  9   Inner sheatlh
      - Material                                                                                   Black PE
      - Nominal thickness                                               mm                           1.4
      - Overall diameter over inner shealth                             mm                          40.66
 10   Armouring
      - Material                                                                     Hard Drawn Round Aluminium Wire
      - No of wire (approx.) / size                                  Nos/mm                      52 2.52
      - Diameter over armouring                                        mm                         45.70
 11   Outer Sheath
      - Material                                                                                   Black PE
      - Nominal thickness                                               mm                           2.6
      - Overall diameter over outer shealth (approx.)                   mm                          51.60
 12   Completed Cable
      - Approx. overall diameter                                        mm                          51.60
      - Approx. weight per kilometer                                    kg                          7819
      - Approx. cable length per drum                                    m                       1000 ± 2.5%
 13   Condition Upon Which Current Carrying
      Capacities are Based
      - Soil thermal resistivity                                      K-m/w                          1.2
                                                                        o
      - Ground temperature                                               C                           25
                                                                        o
      - Ambient air temperature                                          C                           40
      - Burial depth                                                   mm                           800
      - Type of earth bonding-Trefoil                                                        Bonding at both ends
      - Load factor                                                      %                          100
      - Number of circuit                                                                             1
                                                 Page 1 of 2
                                   OLYMPIC CABLE COMPANY SDN. BHD.
11KV SINGLE CORE CROSS-LINKED POLYETHYLENE (XLPE) INSULATED, PVC INNER SHEATHED, ALUMINIUM WIRE ARMOURED, PVC OVERSHEATHED CABLE
                                                    TECHNICAL DATA
                                                                                                        2
REF DESCRIPTION                                                        UNIT                       630 mm x 1C
 14 Minimum Radius of Bend
    - Laid direct in ground                                            mm                            619
    - Laid in duct                                                     mm                            619
    - Laid in air                                                      mm                            619
 15 Minimum interal diameter of duct                                   mm                             82
                                              o
 16 Maximum DC Resistance of Conductor at 20 C                       ohm/km                         0.0283
 17 Maximum Conductor Temperature
                                                                        0
    - Laid direct in ground                                              C                            90
                                                                        0
    - Drawn into duct                                                    C                            90
                                                                        0
    - Laid in air                                                        C                            90
 18 Maximum Current Carrying Capacity Based
    on condition Specified (See Ref : 16)
    - Laid in ground                                                   Amp                           707
    - Drawn into duct                                                  Amp                           661
    - Laid in air                                                      Amp                           955
 19 Conductor Short Time Current Rating
                                                                        0
    -Initial temperature                                                 C                            90
                                                                        0
    -Maximum conductor short time temperature                            C                           250
    Short circuit current rating:-
    -For 1 second                                                       kA                          90.06
    -For 3 second                                                       kA                          51.99
 20 Copper Tape Earth Fault Current Rating
                                                                        0
    - Initial temperature                                                C                            80
                                                                        0
    - Maximum conductor fault teperature                                 C                           200
    - Short circuit current rating:-
    - For 1 second                                                      kA                           0.92
    - For 3 second                                                      kA                           0.53
 21 Maximum Volt Drop at Maximum Conductor
    Temperature
    - For 1 - phase circuits                                         mV/A.m                            -
    - For 3 - phase circuits                                         mV/A.m                          0.18
                                                 Page 2 of 2