VESSEL NAME :- BHAGYA EXPRESS
FIRE / BILGE PUMP CALCULATION: 212 PAX HIGH SPEED CRAFT
Rule Applicable :- HSC 2000
10.3.6    Diameter of bilge main
                              dm = 1.68 √{L (B + D)} + 25 [mm]
          B = moulded breadth of the craft [m] – for monohull =    4.725
          D = moulded depth to the watertight deck [m]=               2.3
          L = length of craft [m] as defined in Chapter 1.            39
          C= Length of compartment
                              Required     dm =            52.81 mm
                              Provided     dm =            100 mm
10.3.7    Branch bilge sunction
                           db = 2.15 √{C (B + D)} + 25 [mm]
                              db is should not be less than 25 mm (As per HSC 2000 PARA 10.3.7)
                            length of   branch bilge
                           compartme suction pipe provide
            compartment       nt(C)     required =db d db=
           Steering Gear            1.8        32.645    50
          Genset Room             2.75         34.450    50
          Engine room               4.6        37.222    50
          Void 11                   3.7        35.961    40
          Void 10                 3.75         36.035    40
          Void 9                  2.76         34.467    40
          Fresh Water Tank        1.38         31.694    40
          Void 7                  4.15         36.609    40
         Luggage Space          4.15         36.609       40
         Void 6                 4.15         36.609       40
         Void 5                 2.76         34.467       40
         Void 4                 1.65         32.320       40
         Void 3                1.115         31.017       40
         Void 2                  0.7         29.768       40
         Void 1                  4.6         37.222       40
10.3.12 Capacity of Bilge pumps
                         Q = (5.75/10^3 ) x dm2 [m3/hour]
                                   =          16.03 [m3/hour]
from HSC 2000
    Number of pumps required =           2 nos        ( AS PER HSC 2000 . RULE 10.9)
    Number of pumps required =           3 nos
Capacity of each pump provided=          25 [m3/hour]
HSC 2000 Rule 7.7.5.1         Capacity of fire Pump
                              =
                   d                     =              1+0.066(L(B+D))0.5
Required fire pump capacity              25 m3/hr
Required no of fire pump                 2 nos
Provided fire pump capacity              25 m3/hr
Provided no of fire pump                 2 nos