Zener Diode Codes PDF
Zener Diode Codes PDF
www.vishay.com
Vishay Semiconductors
Small Signal Zener Diodes
FEATURES
• Very sharp reverse characteristic
• Low reverse current level
• Very high stability
• Low noise
• High reliability
• AEC-Q101 qualified
• Material categorization: for definitions of compliance
please see www.vishay.com/doc?99912
ORDERING INFORMATION
DEVICE NAME ORDERING CODE TAPED UNITS PER REEL MINIMUM ORDER QUANTITY
TLZ-series TLZ-series-GS18 10 000 (8 mm tape on 13" reel) 10 000/box
TLZ-series TLZ-series-GS08 2500 (8 mm tape on 7" reel) 12 500/box
PACKAGE
MOLDING COMPOUND MOISTURE SENSITIVITY
PACKAGE NAME WEIGHT SOLDERING CONDITIONS
FLAMMABILITY RATING LEVEL
MSL level 1
MiniMELF SOD-80 31 mg - 260 °C/10 s at terminals
(according J-STD-020)
600 1.3
Ptot - Total Power Dissipation (mW)
400 8 x 10-4/K
6 x 10-4/K
1.1
4 x 10-4/K
300
2 x 10-4/K
1.0 0
200 - 2 x 10-4/K
- 4 x 10-4/K
0.9
100
0 0.8
0 40 80 120 160 200 - 60 0 60 120 180 240
95 9602 Tamb - Ambient Temperature (°C) 95 9599 Tj - Junction Temperature (°C)
Fig. 1 - Total Power Dissipation vs. Ambient Temperature Fig. 3 - Typical Change of Working Voltage vs.
Junction Temperature
1000 15
TKVZ - Temperature Coefficient
VZ - Voltage Change (mV)
10
100
of VZ (10-4/K)
5
IZ = 5 mA
IZ = 5 mA
10
0
1 -5
0 5 10 15 20 25 0 10 20 30 40 50
95 9598 VZ - Z-Voltage (V) 95 9600 VZ - Z-Voltage (V)
Fig. 2 - Typical Change of Working Voltage under Operating Fig. 4 - Temperature Coefficient of VZ vs. Z-Voltage
Conditions at Tamb = 25 °C
200 50
CD - Diode Capacitance (pF)
Ptot = 500 mW
40
150 Tamb = 25 °C
IZ - Z-Current (mA)
VR = 2 V
30
Tj = 25 °C
100
20
50
10
0 0
0 5 10 15 20 25 15 20 25 30 35
95 9601 VZ - Z-Voltage (V) 95 9607 VZ - Z-Voltage (V)
100 1000
10 IZ = 1 mA
Tj = 25 °C 100
1
5 mA
0.1
10 10 mA
0.01
Tj = 25 °C
0.001 1
0 0.2 0.4 0.6 0.8 1.0 0 5 10 15 20 25
959605 VF - Forward Voltage (V) 95 9606 VZ - Z-Voltage (V)
Fig. 6 - Forward Current vs. Forward Voltage Fig. 9 - Differential Z-Resistance vs. Z-Voltage
100
80
Ptot = 500 mW
IZ - Z-Current (mA)
Tamb = 25 °C
60
40
20
0
0 4 6 8 12 20
95 9604 VZ - Z-Voltage (V)
tp/T = 0.5
100
tp/T = 0.2
tp/T = 0.05
iZM = (- VZ + (VZ2 + 4rzj x T/Zthp) 1/2)/(2rzj)
1
10-1 100 101 102
tp - Pulse Length (ms) 95 9603
TLZ2V4A
2A4
2A4
2A4
2A4
18660_2
Remark
The Zener voltage group TLZ2V4A is printed with max 3 digits 3 times on the surface. The marking should be readable at
minimum 2 times. The third print is allowed to be incomplete due to tolerances in diameter of the glass body.
Cathode indentification
1.6 (0.063)
1.4 (0.055)
*
3.7 (0.146)
3.3 (0.130)
2 (0.079) min.
Document no.:6.560-5005.01-4
Rev. 8 - Date: 07.June.2006 5 (0.197) ref.
96 12070
Vishay Intertechnology, Inc., its affiliates, agents, and employees, and all persons acting on its or their behalf (collectively,
“Vishay”), disclaim any and all liability for any errors, inaccuracies or incompleteness contained in any datasheet or in any other
disclosure relating to any product.
Vishay makes no warranty, representation or guarantee regarding the suitability of the products for any particular purpose or
the continuing production of any product. To the maximum extent permitted by applicable law, Vishay disclaims (i) any and all
liability arising out of the application or use of any product, (ii) any and all liability, including without limitation special,
consequential or incidental damages, and (iii) any and all implied warranties, including warranties of fitness for particular
purpose, non-infringement and merchantability.
Statements regarding the suitability of products for certain types of applications are based on Vishay’s knowledge of typical
requirements that are often placed on Vishay products in generic applications. Such statements are not binding statements
about the suitability of products for a particular application. It is the customer’s responsibility to validate that a particular
product with the properties described in the product specification is suitable for use in a particular application. Parameters
provided in datasheets and/or specifications may vary in different applications and performance may vary over time. All
operating parameters, including typical parameters, must be validated for each customer application by the customer’s
technical experts. Product specifications do not expand or otherwise modify Vishay’s terms and conditions of purchase,
including but not limited to the warranty expressed therein.
Except as expressly indicated in writing, Vishay products are not designed for use in medical, life-saving, or life-sustaining
applications or for any other application in which the failure of the Vishay product could result in personal injury or death.
Customers using or selling Vishay products not expressly indicated for use in such applications do so at their own risk. Please
contact authorized Vishay personnel to obtain written terms and conditions regarding products designed for such applications.
No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document or by
any conduct of Vishay. Product names and markings noted herein may be trademarks of their respective owners.
Please note that some Vishay documentation may still make reference to RoHS Directive 2002/95/EC. We confirm that
all the products identified as being compliant to Directive 2002/95/EC conform to Directive 2011/65/EU.
Vishay Intertechnology, Inc. hereby certifies that all its products that are identified as Halogen-Free follow Halogen-Free
requirements as per JEDEC JS709A standards. Please note that some Vishay documentation may still make reference
to the IEC 61249-2-21 definition. We confirm that all the products identified as being compliant to IEC 61249-2-21
conform to JEDEC JS709A standards.