Tropical Design: Case Study With Rating System

The San Manuel Clay the minor alluvial plain is also classified into two (2) namely; the San Manuel Clay Loam (SmA) with 2-5 percent slope covers an area of 136.22 hectares or .85% and San Manuel clay loam (SmAf1) with 0-2 percent slope, slightly flooded areas covers an area of 108.34 hectares or .67%. The Burgos Clay, the alluvial fan terraces with 2-5 percent slope covers an area of 557.95 hectares or 3.46%. Other areas are identified
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
50 views12 pages

Tropical Design: Case Study With Rating System

The San Manuel Clay the minor alluvial plain is also classified into two (2) namely; the San Manuel Clay Loam (SmA) with 2-5 percent slope covers an area of 136.22 hectares or .85% and San Manuel clay loam (SmAf1) with 0-2 percent slope, slightly flooded areas covers an area of 108.34 hectares or .67%. The Burgos Clay, the alluvial fan terraces with 2-5 percent slope covers an area of 557.95 hectares or 3.46%. Other areas are identified
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 12

TROPICAL

DESIGN
CASE STUDY WITH RATING SYSTEM
HOW TO DO THE CASE
STUDY IN THE PHILIPPINES
SELECT BUILDING & SITE OF DIFFERENT PROJECT TYPES:

1. CIVIC/ INSTITUTIONAL

2. COMMERCIAL

3. RESIDENTIAL HIGHRISE

4. RESIDENTIAL MIDRISE

5. TRANSPORT STRUCTURES

6. RELIGIOUS

7. MEDICAL

8. RECREATIONAL

9. EDUCATIONAL

10.MIXED-USE
HOW TO DO THE CASE
STUDY
• PRESENT THE CLIMATIC DATA ANALYSIS:

• TEMPERATURE

• WIND SPEED & DIRECTION

• RAINFALL / AMOUNT OF PRECIPITATION

• SUNNY DAYS, CLOUDY DAYS


HOW TO DO THE CASE
STUDY
• COMPUTE POINTS FOR BUILDING & SITE
USING GIVEN RATING SYSTEM:

• SUN

• WIND

• RAIN

• VEGETATION
OUTPUTS

• MULTIMEDIA PRESENTATION - CLASSROOM


(MAX. 30 MINS)

• DIGITAL FILE TO BE UPLOADED - PDF /


VIDEO / INFOGRAPHICS / WRITTEN REPORT
SCHEDULE

• CLASS REPORT / PRESENTATION (6 GROUPS


PER MEETING - NOV 5, NOV19, NOV26, DEC3,
DEC10 (EXTRA)

• DIGITAL FILE UPLOAD DEADLINE - DEC10


EVALUATION RATING SYSTEM - 35 PTS

• ROOMS HAVE DIRECT ACCESS TO NATURAL LIGHTING



100% = 10 PTS
• OUTDOOR SPACE IS SHADED WITH TREES 

100% = 10 PTS
• SUN’S HEAT IS USED TO REDUCE HUMIDITY

100% = 10 PTS
• HEAT GAIN IS MINIMIZED WITH THE USE OF ARTIFICIAL SUNSHADING DEVICES 

100% = 5 PTS
EVALUATION RATING SYSTEM - 35 PTS

• RAINWATER IS CAPTURED ON SITE



100% = 10 PTS
• RAINWATER IS REUSED 

100% = 10 PTS
• HUMAN SPACES ARE FLOOD-FREE

100% = 10 PTS
• ADJACENT WATER BODIES OR FEATURES ARE FOUND ON SITE

100% = 5 PTS
EVALUATION RATING SYSTEM - 40 PTS

• ALL INDOOR SPACES HAVE ACCESS TO NATURAL VENTILATION



100% = 10 PTS
• ALL FENESTRATIONS FACE NE OR SW WIND 

100% = 10 PTS
• HOT AIR IS RELEASED FROM INTERIOR SPACES

100% = 10 PTS
• WIND IS USED TO REDUCE HUMIDITY & MOISTURE

100% = 10 PTS
EVALUATION RATING SYSTEM - 40 PTS

• OUTDOOR SITE IS COVERED WITH PLANTS



100% = 10 PTS
• PLANTS ARE IRRIGATED THROUGH RAINWATER / RECYCLED WATER

100% = 10 PTS
• PLANTS PROTECT STRUCTURES FROM SOLAR HEAT GAIN

100% = 10 PTS
• PLANTS PROVIDE SHADE FOR PEOPLE OUTDOORS

100% = 10 PTS
TOTAL RATING SYSTEM - 150 PTS

• SUN

100% = 35 PTS
• WIND

100% = 40 PTS
• RAIN

100% = 35 PTS
• VEGETATION

100% = 40 PTS
OTHER DESIGN STRATEGIES THAT CAN BE GIVEN ADDITIONAL POINTS

• BUILT FORM DESIGNED FOR DISASTER RESILIENCY - 25 PTS


• SITE PLANNING DESIGNED FOR DISASTER RESILIENCY - 25 PTS
• EARTHQUAKE
• TYPHOONS - EXTREME WIND, EXTREME RAINFALL
• VOLCANIC ERUPTION
• STORM SURGE
• PASSIVE ENERGY