0% found this document useful (0 votes)
80 views1 page

South Sumatera Air Quality Limits

This document outlines air quality standards for South Sumatra province, including: 1) Threshold limits for 13 air pollutants including sulfur dioxide, carbon monoxide, nitrogen monoxide, ozone, hydrocarbons, particulate matter, lead, dust fall, fluorides, chlorine, and sulfates. 2) Acceptable measurement periods and methods for each pollutant, such as 1 hour, 24 hours, 1 year, gravimetric analysis, and specific ion electrodes. 3) The standards apply specifically to regencies and chemical industrial areas in South Sumatra province.

Uploaded by

pramadhony
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
80 views1 page

South Sumatera Air Quality Limits

This document outlines air quality standards for South Sumatra province, including: 1) Threshold limits for 13 air pollutants including sulfur dioxide, carbon monoxide, nitrogen monoxide, ozone, hydrocarbons, particulate matter, lead, dust fall, fluorides, chlorine, and sulfates. 2) Acceptable measurement periods and methods for each pollutant, such as 1 hour, 24 hours, 1 year, gravimetric analysis, and specific ion electrodes. 3) The standards apply specifically to regencies and chemical industrial areas in South Sumatra province.

Uploaded by

pramadhony
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
You are on page 1/ 1

Appendix I : South Sumatera Governor Regulation

Number : 17, 2005


Date : May 13th, 2005

Air Ambient Minimum Threshold of South Sumatera Province

No Parameter Time of Minimum Analysis Method Equipment


Measurement Threshold
1 SO2 1 hour 900 µg/Nm3 Pararosanilin Spektrofotometer
(Sulfur Dioxide) 24 hour 365 µg/Nm3
1 Year 60 µg/Nm3
2 CO 1 hour 30.000 µg/Nm3 NDIR NDIR Analyzer
(Carbon Monoxide) 24 hour 10.000 µg/Nm3
1 Year
3 NO2 1 hour 400 µg/Nm3 Saltzman Spektrofotometer
(Nitrogen Monoxide) 24 hour 150 µg/Nm3
1 Year 100 µg/Nm3
4 O3 1 hour 235 µg/Nm3 Chemiluminescant Spektrofotometer
(Oksidan) 1 Year 50 µg/Nm3
5 HC 3 Hours 160 µg/Nm3 Flame Ionization Gas
(hydro Carbon) Chromatography
6 PM10 24 hours 150 µg/Nm3 Gravimetric Hi – Vol
(Particulate < 10 µm)
PM 2,5 24 Hours 65 µg/Nm3 Gravimetric Hi – Vol
(particulate < 2,5 µm) 1 Year 15 µg/Nm3 Gravimetric Hi – Vol
7 TSP 24 Hours 230 µg/Nm3 Gravimetric Hi – Vol
(Dust) 1 Year 90 µg/Nm3
8 Pb (black tin) 24 Hours 2 µg/Nm3 Gravimetric Hi – Vol
1 Year 1 µg/Nm3 Extractive AAS
Pengabuan
9 Dust Fall 30 Days 10 Ton/km2/Month Gravimetric Cannister
(Regency)
20 Ton/km2/Month
(Industry)
10 Total Fluoride (as F) 24 Hours 3 µg/Nm3 Spesific ion Impinger or
90 Days 0,5 µg/Nm3 Electrode Continous
Analyzer
11 Fluor Index 30 Days Colorometric Limed Filter Paper
12 Chlorine & Chlorine 24 Hours 150 µg/Nm3 Spesific ion Impinger or
Dioxide Electrode Continous
Analyzer
13 Sulphat Index 30 Days 1 mg SO3/100cm3 Colorometric Lead Peroxide
Candle
Note : - (*) PM 2,5 was valid in 2002
Number 1 until 13 is only valid for regency/chemical industrial area
Ex: Petro chemical Industry
Sulphate Acid Production Industry

South Sumatera Governor

Syahrial Oesman