XIAN KACISE OPTRONICS TECH CO., LTD.
LC Series Oval Gear Flow Meter
          Introduction
          LC series oval gear flow meter is the main products of our company. LC oval gear flow meter is one of
          the typical displacement meter, used for measurement of pipeline fluid flow under certain pressure. It has
          a simple structure, reliable use and high accuracy, flow field has no special requirements for import and
          export of the pipe, the viscosity of the measured medium range and the characteristics of the flow range
          is very wide. And therefore is widely used in petroleum, chemical industry, medicine, transportation, food
          and other industrial and commercial sector of liquid flow detection. LC series oval gear flow meter is
          particularly suited to the measurement of oil fuel.
          Usage
          LC-A type cast iron oval gear flow meter, widely used in all kinds of oil products and for the measurement
          of the cast iron material not corrosion liquid medium.
          LC-E type cast steel oval gear flow meter, Used for high pressure, low corrosive medium measurement.
          LC-Q type cast iron oval gear flow meter, The rotor for aluminum alloy, is suitable for low viscosity, low
          corrosion, such as gasoline, etc.) the measurement of liquid medium.
          LC-B, C type stainless steel oval gear flow meter, widely used in strong corrosive liquid medium, such as
          acid, alkali, salt and organic compounds, the measurement of liquid medium.
          LC-L type Aluminum alloy oval gear flow meter, is a small oval gear flow meter, widely used in low
          corrosive liquid medium, such as water, such as the measurement of liquid medium.
          Oval gear flow meter technical parameters
          The major component material and the nominal pressure
           case and cover cover board       oval gear                 axle          axle sleeve          nominal
                                                                                                         pressure(Mpa)
LC-A       cast iron         cast iron, engineering material          stainless     bronze(with oil)     1.6
LC-E       cast steel        cast iron, stainless steel               steel         or rolling bearing   below DN50: 6.3
                                                                                                         DN80-100: 4.0
                                                                                                         DN150-200: 2.5
LC-Q       cast iron         cast iron         Al alloy                             graphite             1.6
LC-B, C    stainless steel   stainless steel   stainless steel                      graphite             1.6, 2.5
LC-L       Al alloy          cast iron,        cast iron, Al alloy,                 bronze(with oil)     1.6
                             stainless steel   engineering material                 or rolling bearing
Notes: LC-C texture is OCr18nil2Mo2Ti; LC-B texture is 0Cr18Ni9Ti
2. Flange is convex under 2.5MPa, male and female flange type at 6.3 MPa, and both type is available for 4.0 MPa.
           2.Accuracy: 0.5 grade, 0.2 grade
          Tel: 0086-029-62929722                                                       Email: support@kacise.com
                                                XIAN KACISE OPTRONICS TECH CO., LTD.
    3.Operating temperature: LC-A(-20℃~+60℃),
                               LC-B, E, L(-41℃~+60℃), 60℃~200℃ type can be customized.
                               LC-Q, L: -20℃~+60℃;
    4. Explosion-proof: ExiaⅡCT5, dⅡCT5
    5. Flow range as shown in the table below(unit:m³/h)
                                                     Viscosity (mPa. s)
Model      DN
                       <0.3 0.3~0.8        0.8~2               2~200                  200~1000       1000~200
LC-10      10                0.2-0.5         0.08-0.5 0.08-0.5 0.05-0.5          0.06-0.3 0.03-0.3   0.03-0.2
                                                                                                          0
LC-15      15                0.75-1.         0.3-1.5   0.3-1.5    0.15-1.5       0.2-1.0 0.1-1.0     0.07-0.7
LC-20      20                1.5-3   1-3     0.5-3     0.5-3      0.3-3          0.4-2.1 0.2-2.1     0.15-1.5
LC-25      25        4-6     3-6     2-6     1-6       1-6        0.6-6          0.8-4.2 0.4-4.2     0.3-3
LC-40      40        9-15    7.5-15 5-15     2.5-15    2.5-15     1.5-15         2.1-10.5 1.0-10.5   0.7-7.5
LC-50      50        10-24 8-24      8-24    4.8-24    4.8-24     2.4-24         2.4-16.8 1.6-16.8   1.2-12
LC-B40, 50 40, 50    8-20    6-20    6-20    4-20      4-20       2-20           2.8-14 1.4-14       1.0-10
LC--65     65        27-40 20-40     15-40 8-40        8-40       4-40           5.6-28 2.8-28       2-20
LC-80      80        40-60 30-60     20-60 12-60       12-60      6-60           8.4-42 4.2-42       3-30
LC-100     100       67-100 50-100 34-100 20-100       20-100     10-100         14-70    6-70       5-50
LC-150     150       127-190 95-190 64-190 38-190      38-190     19-190         26.6-133 13.3-133   9.5-95
LC-200     200       227-340 170-340 114-340 56-340    56-340     34-340         47.6-238 23.8-238   17-170
Accuracy             0.5     0.5     0.2     0.5       0.2        0.5            0.2      0.5        0.5
    Note:When the measured liquid viscosity is more than 2000 mpa.S, flow meter adopts viscous
    structure, can be used for 20000 mpa.S or higher. Flow range or parameter negotiable.
   LC-series other special oval gear flow meter
    Far eastone oval gear flow meter overview
    Far eastone oval gear flow meter is composed of ontology and the transmitter, liquid in the pipe flow
    can be directly converted into flow pulse signal or analog signal output. The flow pulse signal or analog
    signals and our display instrument or other secondary instrument and supporting system, which can
    realize remote measurement display. Automatic control, record the need of adjustment.
    Technical index
    1. The level of accuracy: 0.5, 0.2
    2. Working temperature: general work in - 20 ~ + 60 ℃)
    3. The transmitter type: GF, MF, Ag19
    4. The transmitter structure: BGF, FX, LC - 13
    Light-weight Oval gear flow meter overview
    Light-weight oval gear flow meter is mainly in order to reduce flow meter convenient customer use and
    research and development of new type flow meter, divided into new light flow meter.
    (LC – A xx Ⅱseries) and whole aluminum light meter (LC - L, LC - AL series).This series of flow meter
    novel design, light weight, unique and beautiful appearance, convenient assembly, high accuracy, large,
    medium and small flow linear stability, repeatability is good wait for a characteristic.
    Technical index
    1. The level of accuracy: 0.5, 0.2
    2. The nominal pressure: 1.6 MPa
    3. The other technical parameters: see LC - A series
   Tel: 0086-029-62929722                                                       Email: support@kacise.com
                                                   XIAN KACISE OPTRONICS TECH CO., LTD.
     4. Main component materials in the following table
model        case and cover cover board           oval gear                        axle              axle sleeve
LC-L         Al alloy         cast iron,          Al alloy,                        stainless steel   oil bronze,
                              stainless steel     engineering materials,                             graphite,
                                                  cast iron                                          rolling bearing
LC-AxxⅡ      cast  iron       cast iron           Al alloy, cast iron                                oil bronze,
                                                                                                     graphite
      LC-U series heat preservation jacket oval gear flow meter
      To facilitate easy to solidification of room temperature, or under a certain temperature condensation,
      easily crystallized media normal reaction in the pipeline transportation and traffic monitoring, often
      need to heating system of the pipeline medium, medium melt and heat preservation. But because the
      oval gear flow meter installation place is not allowed to pass by steam (purpose is to prevent damage
      meter), therefore we design oval gear flow meter with insulation jacket products, which outside the
      meter shell increase insulation jacket, make has solidified medium melt flow meter, and maintain a
      certain temperature, so as to ensure the normal operation of flow meter. Oval gear flow meter installed
      in front of the filter can also adopt the structure of insulation jacket. Heat preservation jacket in and out
      of the structure, generally according to DN15 caliber flange design, special requirements can also
      design the user interface. Heat preservation jacket nominal pressure is 0.5 MPa, can also be designed
      according to customer special requirements.
      LC-D series mechanical quantitative oval gear flow meter
      LC – D type mechanical quantitative oval gear flow meter (hereinafter referred to as the flow meter) is a
      special flow meter, it is composed of oval gear flow meter, reducer and quantitative counter of three
      parts, can accurately measuring the cumulative amount of the liquid, when the number to the expected
      value, shut automatically turn on the electric circuit control valve, thus satisfies the requirement of flow
      metering control.
      Volumetric flow meter parts and structure form selection reference
      Counter and governor
      1. counter: A, A1, J1, Z, A5, A6, M11, M12, S1, BELZ
counter     performance parameters                                regular configuration
A           pointer indicating, 6-bit wheel accumulation,         pointer indicating:
            unit: L                                               DN10: 1L/circle
A1          same as above                                         below DN25: 10L/circle
            configurable transmitter                              DN40: 100L/circle
J1          pointer indicating,                                   below DN65: 100L/circle;
            6-bit wheel accumulation, unit: L,                    above DN80 1000L/circle
            configurable transmitter
A5          6-bit wheel accumulation indicator for cumulant.
            configurable transmitter                              pointer indicating:
A6          double roller indicating,                             DN10: 1L/circle
            6-bit wheel for cumulant, 4-bit wheel for single      below DN25: 10L/circle
            run cumulant,                                         below DN50: 100L/circle
            return zero is available                              DN65, DN80: 100L/circle, 1000L/circle
     Tel: 0086-029-62929722                                                          Email: support@kacise.com
                                                 XIAN KACISE OPTRONICS TECH CO., LTD.
Z          Same as above.                                       above DN100: 1000L/circle
           Transmitter is not available.
M11        double roller indicating,                            For flowmeters above DN80.
           7-bit small wheel for cumulant, 5-bit big wheel      DN80, DN100: cumulantx10L,
           for single run cumulant, return zero is available.   above DN150: cumulantx100L.
           Flowmeter output transmission shaft is syntropy
            with the counter display.
M12        Same as above. Only difference is: flowmeter
           output transmission shaft is 90 ° direction with
           the counter display.
S1         mechanical transient flow indicator display          instantaneous flow values display
ELZ        direct-reading electronic display                    used for series flow meter
           It displays cumulant, single run, instantaneous
           flow and single reset.
BELZ       explosion-proof compact counter                      used for volumetric flowmeter
           It displays cumulant, instantaneous flow and
           output pulse, analog signal
BXZ        small explosion-proof flow display counter           used for volumetric flowmeter
           It displays cumulant and instantaneous flow.
      2. governor: JT1, GT/F, Y1, Y2, G
      3. Volumetric flowmeter configuration is as follows
configuration     Height reference size       function
A                 78                          Used for flowmeters below DN40. Needle wheel display the
no speeder                                    cumulant.
A1                105                         Used for flowmeters below DN40. Needle wheel display the
no speeder                                    cumulant. Can match with GF, MF transmitter.
Z                 74.5~82.5                   Used for various types of flowmeter. The double word wheel is
no speeder                                    with return zero function, long word wheel display cumulative flow.
                                              Pointer and small word wheel can return to zero.
J1+JT1            94+35=129                   Used for flowmeters above DN50. Pointer, wheel shows
                                              cumulative flow. Can match with GF, MF transmitter.
A5+Y1             64+56                       Used for LL type flowmeter. Pointer, wheel shows cumulative flow.
                                              Can match with GF, MF transmitter.
A5+Y2             64+85.5                     Used for LL type flowmeter. Pointer, wheel shows cumulative flow.
                                              Can match with GF, MF transmitter. Can match with GF, MF
                                              transmitter.
A6+Y1             64+56                       Used for LL type flowmeter. The double word wheel is with return
                                              zero function, long word wheel display cumulative flow. Pointer
                                              and small word wheel can return to zero.
A6+Y2             64+85.5                     Used for LL type flowmeter. The double word wheel is with return
                                              zero function, long word wheel display cumulative flow. Pointer
                                              and small word wheel can return to zero. Can match with GF, MF
                                              transmitter.
     Tel: 0086-029-62929722                                                      Email: support@kacise.com
                                                    XIAN KACISE OPTRONICS TECH CO., LTD.
A5+G               64+106                        Used for LLT type flowmeter, Needle wheel display the
                                                 cumulant. Can match with GF, MF transmitter.
A6+G               64+106                        Used for LLT type flowmeter. The double word wheel is with return
                                                 zero function, long word wheel display cumulative flow. Pointer
                                                 and small word wheel can return to zero. Can match with GF, MF
                                                 transmitter.
A5+GT/F            64+67.5                       Used for LC type flowmeter. Needle wheel display the cumulant.
                                                 Can match with GF, MF transmitter.
A6+GT/F            64+67.5                       Used for LC type flowmeter. Needle wheel display the cumulant.
                                                 Can match with GF, MF transmitter. Can match with GF, MF
                                                 transmitter.
M11+GT/F           150+67.5                      Used in a variety of special requirements. Big word back to zero
                                                 counter display and input shaft, according to the vertical direction.
                                                 Can match with GF, MF transmitter.
M12+GT/F           150+67.5                      For LBJ flowmeter, Output shaft of ontology and big word back to
                                                 zero counter display is in 90 °direction, can match GF, MF.
S1transient        85.5+62                       Used in all kinds of more than DN50 flowmeter for instantaneous
display                                          flow display
ELZ, ELZ           165(145)                      See the product introduction.
    4. Radiator is used for high temperature, as below:
                            DN10~40                                               DN50~200
                 T1                         T2                            T1                         T2
    Note:T is temperature flow meter for 60-120 ℃. If no transmitter, can be without radiator.
              T1 is high temperature flow meter for 120-200 ℃, with long radiator.
              T2 is high temperature flow meter for 60-120 ℃, with transmitter and short radiator.
   Oval gear flowmeter Ordering Information
                                                    Note
   type code                   LC-                  Oval gear flowmeter
   special mark                U                    With insulation jacket structure
                               G                    Pipe thread connection
                               H                    Welded steel flow meter
                               P                    Nuclear power products
                               PI                   Nuclear seismic products
   special function            D                    Mechanical quantitative flow meter
                               N                    High viscosity liquid flow meter
                               SP                   Food flowmeter
   Tel: 0086-029-62929722                                                              Email: support@kacise.com
                                             XIAN KACISE OPTRONICS TECH CO., LTD.
                          T1, T2             Thermal zone cooling tube
                          Q                  Measuring gas flow meter
material symbol           shell    A         cast iron flowmeter
                                   B/C       stainless steel flowmeter
                                   E         cast steel flowmeter
                                   L         Al alloy flowmeter
                          rotor    A         cast iron
                                   B/C       stainless steel
                                   L         Al alloy
                                   Z         engineering material
nominal diameter          10…200             nominal diameter from 10mm to 200mm
special requirements      S(K)               flange reducing(flaring)
                          Ⅱ                  Improved type
nominal pressure          .2                 nominal pressure 1.6MPa
                          .3                 nominal pressure 2.5MPa
                          .4                 nominal pressure 4.0MPa
                          .6                 nominal pressure 6.3MPa
counter                   A, A1              used for flowmeter below DN40
                          A5, J1             used for flowmeter above DN50
                          BELZ               type electronic digital display counter
                          A6, Z              back to zero counter
                          BXZ                small digital display counter
sender unit               FX                 Used for LC - 13 filling type flowmeter
                          GF-Ⅰ               12V Three wire system photoelectric transmitter
                          GF-Ⅱ               24V Three wire system photoelectric transmitter
                          MF                 4-20mA Analog output transmitter
accuracy                  J                  high precision flowmeter
Note:
1. If the oval gear material and shell material are same, no need to note the oval gear material.
2. Material B-0Cr18Ni9Ti; C-0Cr18Nil2Mo2tI
3. Add B before the transmitter, means explosion-proof transmitter.
4.High temperature meter don't need to be with radiator, just note “T”.
Special requirements:
MI                 HG               SH                   SM              AS               JS
military           chemical         petrochemical        shipment        American         Japanese
industry           engineering      engineering                          standard         standard
Tel: 0086-029-62929722                                                        Email: support@kacise.com