Service Training
MALAGA
301.5 MHEX
V. IMPLEMENTS
Thorben
MAY 1998
301.5 MHEX
CHAPTER : Implements
Page: 2
301.5 MHEX
CHAPTER : Implements
1. Accumulator
2. Pilot Pressure Nipple
(Located in boom circuit - not adjustable)
Page: 3
301.5 MHEX
CHAPTER : Implements
1. Manual Boom Lowering
Page: 4
301.5 MHEX
CHAPTER : Implements
CONFLUENCE VALVE
SINGLE COMBINED
FLOW FLOW
Pilot Tank
Pressure
Port PA
Port PA
Port PB
Port PB
Pilot
Tank Pressure
The Caterpillar 301.5 MHEX is equipped with the combined
flow system.
Page: 5
301.5 MHEX
CHAPTER : Implements
Unload Position
(Single Flow System)
Auxiliary 0 Kgf/cm2 Swing
Circiut Motor
Pilot
Pressure
P3
P2 P3
Tank
Tank
Tank Tank
When the safety lever is in the up positiom, the pilot
pressure is cut and the P3 flow is connected to the tank
line.
Boom swing, blade and swing can not be operated.
Page: 6
301.5 MHEX
CHAPTER : Implements
Single Flow System
Auxiliary Swing
Circiut Motor
35 Kgf/cm2
P3
Pilot
Pressure
P2 P3
Tank
Tank
Tank Tank
When the safety lever is in the down position, pilot
pressure is applied to port PA and shifts the valve to the
single flow position.
This position of the valve seperates the flow from P2 and
P3.
Page: 7
301.5 MHEX
CHAPTER : Implements
Combined Flow System
Tank
Auxiliary Swing
Circiut Motor
P3
P2 P3
Pilot
Pressure
35 Kgf/cm2
Tank Tank
Tank
When the safety lever is in the down position, the pilot
pressure is applied to port PB and shifts the valve to the
combined flow position.
This position of the valve allows the auxiliary valve to work
with the combined flow of P2 and P3.
Page: 8