Using HyperTerminal
1 of 6
Table of Contents
          1.   Connecting the device.…………………….3
          2.   Starting HyperTerminal…………………….5
          3.   Configuring RS-232…….…………………….6
          4.   Configuring TCP/IP……….…………………..7
          5.   ASCII Setup……………………………………….8
          6.   Check Communcations…………………….10
          7.   Capturing text…………………………………..11
                                                  2 of 6
Connecting the Device
  1   Locate the serial cable or ethernet cable for   1   2
      your device.
      If your computer does not have a serial port,
      you will need a USB to serial adapter.
      Here are a few examples of cables that can be   3   4
      used or are issued with the device:
      1. RS-232 cable (DB9 F to 3.5 ST/M)
           (part # 2410334)
      2. RS-232 null modem cable (DB9 F/F)
           (part # 2200962)
      3. RS-232 USB adapter (USB A to DB9 M)
           (part # 2761737)                           5   6
      4. RS-232 USB adapter, null (USB A to DB9 F)
           (part # 2675479)
      5. USB cable (USB A to USB B)
      6. Ethernet cable, standard.
                                                              3 of 6
Connecting the Device
  2   Connect the serial or USB cable to your
      computer.
      If using a ethernet or TCP/IP connection, make
      sure the ethernet cable is connected and
      connected to a network.
  3   Connect the serial cable or the ethernet cable to
      the device.
                                                          4 of 6
Starting HyperTerminal
  1   Check to see if your computer has a program
      called Terminal or HyperTerminal.
      Windows XP comes with the HyperTerminal.
      This is usually located in the Accessories folder
      and then the communications folder.
      Later versions of Windows, such as 7 or 8, don’t
      come with the HyperTerminal and must be
      purchased separately.
  2   Click on the icon to use HyperTerminal.
  3   Name the Connection Description. This can be
      anything and has no bearing on the data
      collected. For this example, we will use “asdf”.
      Click on the OK button.
                                                          5 of 6
Configuring RS-232
   1   In the Connect To window select the proper
       communication port from the computer to the
       device.
       Most computers that have a RS-232 port will be
       COM1. If you are using a USB to RS-232
       adapter, this will usually be COM5 or higher.
       Now, Click on Configure..
   2   In the COM Properties, Port Settings, select the
       following:
       Bits per second:      2400 or 9600
       (this can be different, check the device settings)
       Data Bits:           8
       Parity:              None
       Stop bits:           1
       Flow control:         None
       Then click on OK.
                                                            6 of 6
Configuring TCP/IP (ethernet)
   1   In the Connect To window select the proper
       communication port from the computer to the
       Fluke device.
       For an ethernet connection select the TCP/IP
       (Winsock) from the drop down menu.
       Now, Click on Configure..
   2   In the Connect To properties select the following:
       Host address:         129.196.204.181
       (this will be different for every device, check the
       device settings or manual for settings)
       Port Number:           10001 or 3490
       (this will be different for every device, check the
       device settings or manual for settings)
       Connect using:       TCP/IP (Winsock)
       Then click on OK.
                                                             7 of 6
ASCII Setup
  1   You will return back to the Connect window, click OK
  2   Select File menu.
      Click on Properties.
  3   At the Properties window, select
      the Settings tab at the top.
             4321                                            4321
                                                                    8 of 6
ASCII Setup
  4   Click on the ASCII Setup… button.
  5   Select the following features by clicking on the
      box on the left next to the line.
                                                         4321
      Send line ends with line feeds
      Echo typed characters locally
      Append line feeds to incoming line ends
      Now click, OK
                                                                9 of 6
Check Communications
  1   You will return back to the Properties window,
      click OK
  2   Check the communications by typing a command.
      *idn? or *ver are common commands. These are
      not used by every unit
      *idn? should return the Manufacturer, Model,
      Serial number, and the Firmware version.
      *ver should return the Model and the Firmware
      version.
                                                       10 of 6
Capturing text
  1   Before streaming or printing the data from the
      device, we will need to capture the text that is
      coming from the device.
      Click on Transfer
      Click on Capture Text
  2   In the Capture Text window at the File line, enter
      the drive you wish to save to and enter the name
      of the file followed by a .TXT extension.
      Example: C:\1620A May 2013.txt
      Then, click Start
      The HyperTerminal will now capture or record the
      lines of information and place the data in the file
      you chose.
                                                            11 of 6
Capturing text
  3   After the data is done transferring, the capturing
      of the data will need to be stopped.
      Click on the Transfer menu.
  4   Under Capture Text, Click on Stop.
      This will stop writing data to the file and conclude
      the process.                                           4321
                                                                    12 of 6