Floating Head Heat Exchanger
General Assembly view
Gaskets
Tube side Inlet Shell side Inlet
Gasket
Floating Head
Shell Bundle
Back Cover
Distributor
Saddle
Tube side Outlet Shell side Outlet
Tube Sheet
1
Floating Head Heat Exchanger
Split View of Parts
Gasket Gasket Split ring Spacer Gasket
Gasket
Tube Bundle
Tube sheet Tube sheet Floating
Distributor Head Back Cover
Shell
Floating
Head Detail
2
Causes of Gasket Leakage
• Wrong Gasket selection
• Insufficient Tightening
• Non -Uniform Tightening
• Thermal stress across the fasteners –Thermal expansion or contraction
• Thermal Shock
• Over pressurization
• Tube to Tube Sheet leakage
• Difference in height of pass partition and tube sheet sealing surface
• Air in the liquid line ( Process line/ Steam line / Water line etc. is not
vented properly) 3
Leakage Testing Procedure
Blind Inlets-Outlets at Disconnect and remove
plant area Floating Head with gasket
Disconnect and remove Install the bundle puller
Distributor with gasket
Disconnect and remove Pull the bundle out
Back cover with gasket
Bundle Puller
Ground level
4
Lower the bundle and Lift the bundle puller with
take to hydro-jetting area clean bundle and new gasket,
Clean Shell and covers ready for reinstallation
Bundle Puller
Ground level 5
Reinsert the bundle by Lower the bundle puller to
bundle puller the ground and take it away
Bundle Puller
Ground level
6
Shell Side Hydro-test
Install front Test Ring with Install Pressure Gauge Raise the pressure up to
gasket value given by Inspection
Connect water pump
Install back Test Ring Check leakages from
with gasket Fill the shell by water tubes
Install Blinds in shell
PG
Ground level Water Pump
7
Shell Side Hydro-test …
Check leakages from tubes continuation
PG
“A” “B”
Water
View “A”
Water
View “B”
8
Discharge water from Reinstall distributor Remove Test Ring &
shell drain with new gasket & gasket [floating head
Remove Test Ring & tight bolts side]
gasket [distributor side] Blind Distributor in & Reinstall Floating Head
out with split flange, new
gasket & tight bolts
PG
Drain
9
Tube Side Hydro-test
Install PG in distributor Check floating head Discharge the water,
top nozzle gasket sealing remove PG and water
Connect water pump Check distributor gasket pump
sealing Remove blinds form
Fill tube side by water
distributor nozzle and
Raise the pressure up to
value given by Inspection
tight bolts
PG PG
Drain
Water Pump
10
Shell Side Final Hydro-test
Install Back cover with Check Back cover Discharge the water,
Gasket gasket sealing remove PG and water
Connect water pump pump
Check bundle to shell
Fill Shell side by water gasket sealing Remove blinds form
shell nozzles and tight
Raise the pressure up to bolts
value given by Inspection
PG
Drain
Water Pump
11