Test report

New green bottle test on Line 5


September 24, 2024
From 3:10 p.m. to 6:10 p.m.
For 62 pallets
Test actors

Micheal OUAMBO: Test Coordinator

Tchabo Miguel: Team leader

Fabrice and Chef Achille: Supervisors


Description of the procedure used

• Get operators aware of the on-going test.


• Zeroing the counters of EBI (Empty Bottle Inspector).
• Physical demarcation of sample bottles on the line.
• Stop the conveyors if necessary when there is a risk of test bottles
meeting other bottles.
• Take the counters at the end of the test.
Test objectives

• Determine new glass bottles quality before injection on the line

• Evaluate the impact of the machines on final chipped mouth


percentage at EBI
Test results

Machines Counter Start End Counter


Depalletizer 37 99 Palets
Stripper 0 3955 Crates
EBI (treated container) 0 46006 Bottles
EBI (counter sorter) 0 43 Bottles
EBI (Ejector 1) 0 323 Bottles
EBI (Ejector 2) 0 1861 Bottles
2 pallets sorting results
• 08 chipped mouth bottle and 01 missing
• 0.5% of chipped mouth over 1584 btls (2 pallets)
Analyse

We see:
4.75% rejection including
0.7% through ejector 1 and
4.04% by ejector 2
We see facts on the ground:
Some bottles without any problem
to the naked eye were ejected by
Photo EBI counters End of test the ejector
Analyse Residual liquid
0.08%
Ejector 1 Ejector 2
0.70% 4.04%
Bottles percentage

Photo EBI counters End of test

Good bottles
Good bottles 95.18% Ejector 1
Residual liquid Ejector 2
Analyse

0.20%
0.50%
Percentage loss bottles

Photo EBI counters End of test

Good bottles chipped mouth before depalletizer Other


99.30%
Conclusion

• 0.7% of chipped bottles identified by the EBI are due to 0.5%


before depalettizer.

• Packaging facility up to the EBI is responsible for 0.2% of


chipped mouth rejection.

A second test will be carried out to confirm the current one.