{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2024,7,24]],"date-time":"2024-07-24T07:55:22Z","timestamp":1721807722463},"reference-count":69,"publisher":"American Scientific Publishers","issue":"8","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["j med imaging hlth inform"],"published-print":{"date-parts":[[2021,8,1]]},"abstract":"<jats:p>The dual fluoroscopic imaging system (DFIS) is a new non-invasive motion analysis system that does not interfere with movement, has high precision and repeatability and is not affected by the errors caused by the relative movement of skin and soft tissues. DFIS has been recently used\n in the field of sports medicine. This narrative review focuses on relevant literature on the origin, development and mechanism of action of DFIS and summarises the application of DFIS in injury and rehabilitation treatment, such as the reliability of test results; the position relationships\n of bony structures in the shoulder, lumbar spine, knee joint and ankle joint during exercise and its six degree-of-freedom (6DOF) movement to calculate cartilage deformation, contact area\/trajectory and ligament strain. This article puts forward the problems encountered in practice that need\n to be solved and looks forward to the future applications of DFIS in the field of sports, especially in injury prevention and treatment.<\/jats:p>","DOI":"10.1166\/jmihi.2021.3579","type":"journal-article","created":{"date-parts":[[2021,7,10]],"date-time":"2021-07-10T04:59:06Z","timestamp":1625893146000},"page":"2067-2076","source":"Crossref","is-referenced-by-count":1,"title":["Advances in the Application of the Dual Fluoroscopic Imaging System in Sports Medicine: A Literature Review"],"prefix":"10.1166","volume":"11","author":[{"given":"Cui","family":"Zhang","sequence":"first","affiliation":[{"name":"School of Kinesiology, Shanghai University of Sport, Shanghai 200438, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Xiaole","family":"Sun","sequence":"additional","affiliation":[{"name":"School of Kinesiology, Shanghai University of Sport, Shanghai 200438, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yunqi","family":"Tang","sequence":"additional","affiliation":[{"name":"School of Kinesiology, Shanghai University of Sport, Shanghai 200438, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Shaobai","family":"Wang","sequence":"additional","affiliation":[{"name":"School of Kinesiology, Shanghai University of Sport, Shanghai 200438, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Dongqiang","family":"Ye","sequence":"additional","affiliation":[{"name":"School of Kinesiology, Shanghai University of Sport, Shanghai 200438, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Weijie","family":"Fu","sequence":"additional","affiliation":[{"name":"School of Kinesiology, Shanghai University of Sport, Shanghai 200438, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yu","family":"Liu","sequence":"additional","affiliation":[{"name":"School of Kinesiology, Shanghai University of Sport, Shanghai 200438, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Lingyan","family":"Huang","sequence":"additional","affiliation":[{"name":"School of Kinesiology, Shanghai University of Sport, Shanghai 200438, China"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"17","reference":[{"issue":"(3)","key":"r1","doi-asserted-by":"crossref","first-page":"pp.533","DOI":"10.1249\/MSS.0b013e3181f1e491","article-title":"Knee kinematic profiles during drop landings: A biplane fluoroscopy study.","volume":"43","author":"Torry","year":"2011","journal-title":"Medicine & Science in Sports & Exercise"},{"issue":"(1)","key":"r2","doi-asserted-by":"crossref","first-page":"pp.102","DOI":"10.1177\/0363546504265577","article-title":"In vivo articular cartilage contact kinematics of the knee: An investigation using dualorthogonal fluoroscopy and magnetic resonance image-based computer models.","volume":"33","author":"Li","year":"2005","journal-title":"American Journal of Sports Medicine"},{"issue":"(2)","key":"r3","doi-asserted-by":"crossref","first-page":"pp.96","DOI":"10.2519\/jospt.2012.3584","article-title":"Dynamic in vivo glenohumeral kinematics during scapular plane abduction in healthy shoulders.","volume":"42","author":"Matsuki","year":"2012","journal-title":"Journal of Orthopaedic & Sports Physical Therapy"},{"issue":"(3)","key":"r4","doi-asserted-by":"crossref","first-page":"pp.446","DOI":"10.1016\/j.arthro.2015.08.031","article-title":"Alterations in glenohumeral kinematics in patients with rotator cuff tears measured with biplanefluoroscopy.","volume":"32","author":"Millett","year":"2016","journal-title":"Arthroscopy the Journal of Arthroscopic & Related Surgery"},{"issue":"(2)","key":"r5","doi-asserted-by":"crossref","first-page":"pp.155","DOI":"10.1016\/j.clinbiomech.2013.11.018","article-title":"In vivo loads in the lumbar L3-4 disc during a weight lifting extension.","volume":"29","author":"Wang","year":"2014","journal-title":"Clinical Biomechanics"},{"issue":"(12)","key":"r6","doi-asserted-by":"crossref","first-page":"pp.2671","DOI":"10.1007\/s00586-013-2777-6","article-title":"Investigation of coupled bending of the lumbar spine during dynamic axial rotation of the body.","volume":"22","author":"Shin","year":"2013","journal-title":"European Spine Journal"},{"issue":"(1)","key":"r7","doi-asserted-by":"crossref","first-page":"pp.170","DOI":"10.1177\/0363546511423746","article-title":"In vivo tibiofemoral kinematics during 4 functional tasks of increasing demand using biplane fluoroscopy.","volume":"40","author":"Myers","year":"2012","journal-title":"American Journal of Sports Medicine"},{"key":"r8","doi-asserted-by":"crossref","first-page":"pp.52","DOI":"10.1016\/j.gaitpost.2018.04.022","article-title":"The effect of functional bracing on the arthrokinematics of anterior cruciate ligament injured knees during lunge exercise.","volume":"63","author":"Jalali","year":"2018","journal-title":"Gait Posture"},{"issue":"(8)","key":"r9","doi-asserted-by":"crossref","first-page":"pp.1081","DOI":"10.1002\/jor.20593","article-title":"In vivo cartilage contact deformation of human ankle joints under full body weight.","volume":"26","author":"Wan","year":"2008","journal-title":"Journal of Orthopaedic Research"},{"issue":"(4)","key":"r10","doi-asserted-by":"crossref","first-page":"pp.1402","DOI":"10.1007\/s00167-014-3084-4","article-title":"Normative rearfoot motion during barefoot and shod walking using biplane fluoroscopy.","volume":"24","author":"Campbell","year":"2016","journal-title":"Knee Surgery Sports Traumatology Arthroscopy"},{"issue":"(2)","key":"r11","doi-asserted-by":"crossref","first-page":"pp.300","DOI":"10.1016\/S0021-9290(02)00336-6","article-title":"ISB recommendation on definition of joint coordinate systems for the reporting of human joint motion-part I: Ankle, hip and spine.","volume":"36","author":"Baker","year":"2003","journal-title":"Journal of Biomechanics"},{"issue":"(5)","key":"r12","doi-asserted-by":"crossref","first-page":"pp.981","DOI":"10.1016\/j.jbiomech.2004.05.042","article-title":"ISB recommendation on definitions of joint coordinate systems of various joints for the reporting of human joint motion-Part II: Shoulder, elbow, wrist and hand.","volume":"38","author":"Wu","year":"2005","journal-title":"Journal of Biomechanics"},{"key":"r13","article-title":"Based on the three-dimensional finite element method to explore the influence of abnormal trajectory of tibiofemoral joint on the meniscus and cartilage stress distribution after ACL fracture.","volume-title":"Third Military Medical University, Doctoral Dissertation.","author":"Chen","year":"2013"},{"issue":"(9)","key":"r14","doi-asserted-by":"crossref","first-page":"pp.1303","DOI":"10.1016\/j.medengphy.2011.12.021","article-title":"The accuracy and repeatability of an automatic 2D-3D fluoroscopic image-model registration technique for determining shoulder joint kinematics.","volume":"34","author":"Zhu","year":"2012","journal-title":"Medical Engineering & Physics"},{"key":"r15","article-title":"Research on 2D-3D non-rigid registration method in the reconstruction of 3D femoral model.","volume-title":"Harbin Institute of Technology, Master Thesis.","author":"Sun","year":"2012"},{"issue":"(1)","key":"r16","first-page":"pp.1","article-title":"New fluoroscopic imaging technique for investigation of 6DOF knee kinematics during treadmill gait.","volume":"4","author":"Li","year":"2009","journal-title":"Journal of Orthopaedic Surgery & Research"},{"key":"r17","first-page":"pp.50","article-title":"From X-ray to synchrotron radiationcommemorating the 100 years since the discovery of X-ray by Roentgen.","volume":"6","author":"Xuan","year":"1995","journal-title":"Science"},{"key":"r18","first-page":"pp.1","article-title":"Localization of cardiac volume and patient features in inverse geometry X-ray fluoroscopy.","volume":"01","author":"Speidel","year":"2017","journal-title":"Proceedings of SPIE\u2014The International Society for Optical Engineering"},{"issue":"(4)","key":"r19","first-page":"pp.836844","article-title":"Fluoroscopic and gait analyses for the functional performance of a custommade total talonavicular replacement.","volume":"56","author":"Belvedere","year":"2017","journal-title":"Journal of Foot & Ankle Surgery Official Publication of the American College of Foot & Ankle Surgeons"},{"issue":"(1)","key":"r20","doi-asserted-by":"crossref","first-page":"pp.44","DOI":"10.1016\/j.gaitpost.2011.03.008","article-title":"Quantifying skin motion artifact error of the hindfoot and forefoot marker clusters with the optical tracking of a multi-segment foot model using single-plane fluoroscopy.","volume":"34","author":"Shultz","year":"2011","journal-title":"Gait & Posture"},{"issue":"(3)","key":"r21","first-page":"pp.1","article-title":"Intervertebral anticollision constraints improve out-of-plane translation accuracy of a single-plane fluoroscopy-to-CT registration method for measuring spinal motion.","volume":"40","author":"Lin","year":"2013","journal-title":"Medical Physics"},{"issue":"(7)","key":"r22","doi-asserted-by":"crossref","first-page":"pp.1682","DOI":"10.1016\/j.jbiomech.2014.02.031","article-title":"Detecting condylar contact loss using single-plane fluoroscopy: A comparison with in vivo force data and in vitro bi-plane data.","volume":"47","author":"Prins","year":"2014","journal-title":"Journal of Biomechanics"},{"issue":"(3)","key":"r23","doi-asserted-by":"crossref","first-page":"pp.411","DOI":"10.1016\/j.medengphy.2012.10.004","article-title":"In-vitro validation of a non-invasive dual fluoroscopic imaging technique for measurement of the hip kinematics.","volume":"35","author":"Lin","year":"2013","journal-title":"Medical Engineering & Physics"},{"issue":"(1)","key":"r24","doi-asserted-by":"crossref","first-page":"pp.8","DOI":"10.1016\/j.jot.2013.11.001","article-title":"Application of computer-assisted imaging technology in human musculoskeletal joint research.","volume":"2","author":"Liu","year":"2014","journal-title":"Journal of Orthopaedic Translation"},{"issue":"(7)","key":"r25","doi-asserted-by":"crossref","first-page":"pp.1300","DOI":"10.1016\/j.jbiomech.2013.02.010","article-title":"A novel dual fluoroscopic imaging method for determination of THA kinematics: In-vitro and in-vivo study.","volume":"46","author":"Tsai","year":"2013","journal-title":"Journal of Biomechanics"},{"issue":"(8)","key":"r26","doi-asserted-by":"crossref","first-page":"pp.1714","DOI":"10.1177\/0363546511404922","article-title":"Measurements of tibiofemoral kinematics during soft and stiff drop landings using biplane fluoroscopy.","volume":"39","author":"Myers","year":"2011","journal-title":"American Journal of Sports Medicine"},{"issue":"(9)","key":"r27","first-page":"pp.13341341","article-title":"Left and right ventricular lead positions are imprecisely determined by fluoroscopy in cardiac resynchronization therapy: A comparison with cardiac computed tomography.","volume":"16","author":"Sommer","year":"2014","journal-title":"Europace"},{"issue":"(6)","key":"r28","doi-asserted-by":"crossref","first-page":"pp.1775","DOI":"10.1016\/j.arth.2018.01.040","article-title":"The use of fluoroscopy during direct anterior hip arthroplasty: Powerful or misleading?","volume":"33","author":"James","year":"2018","journal-title":"Journal of Arthroplasty"},{"issue":"(4)","key":"r29","doi-asserted-by":"crossref","first-page":"pp.555","DOI":"10.1016\/j.jbiomech.2015.01.021","article-title":"Asymmetric hip kinematics during gait in patients with unilateral total hip arthroplasty: In vivo 3-dimensional motion analysis.","volume":"48","author":"Tsai","year":"2015","journal-title":"Journal of Biomechanics"},{"issue":"(9)","key":"r30","first-page":"pp.18911898","article-title":"Weight-bearing condyle motion of the knee before and after cruciate-retaining TKA: In-vivo surgical transepicondylar axis and geometric center axis analyses.","volume":"49","author":"Dimitriou","year":"2016","journal-title":"Journal of Biomechanics"},{"key":"r31","doi-asserted-by":"crossref","first-page":"pp.102","DOI":"10.1016\/j.clinbiomech.2015.12.006","article-title":"In-vivo analysis of flexion axes of the knee: Femoral condylar motion during dynamic knee flexion.","volume":"32","author":"Feng","year":"2015","journal-title":"Clinical Biomechanics"},{"issue":"(4)","key":"r32","doi-asserted-by":"crossref","first-page":"pp.712","DOI":"10.1016\/j.gaitpost.2013.03.004","article-title":"Kinematic characteristics of the tibiofemoral joint during a step-up activity.","volume":"38","author":"Li","year":"2013","journal-title":"Gait & Posture"},{"issue":"(2)","key":"r33","doi-asserted-by":"crossref","first-page":"pp.257","DOI":"10.1002\/jor.22217","article-title":"Highknee valgus in female subjects does not yield higher knee translations during drop landings: A biplane fluoroscopic study.","volume":"31","author":"Torry","year":"2013","journal-title":"Journal of Orthopaedic Research"},{"issue":"(4)","key":"r34","doi-asserted-by":"crossref","first-page":"pp.604","DOI":"10.1115\/1.2206199","article-title":"Validation of a new model-based tracking technique for measuring three-dimensional, in vivo glenohumeral joint kinematics.","volume":"128","author":"Bey","year":"2006","journal-title":"Journal of Biomechanical Engineering"},{"issue":"(3)","key":"r35","doi-asserted-by":"crossref","first-page":"pp.408","DOI":"10.1016\/j.jbiomech.2010.10.003","article-title":"Non-invasive determination of coupled motion of the scapula and humerus\u2014An in-vitro validation.","volume":"44","author":"Massimini","year":"2011","journal-title":"Journal of Biomechanics"},{"issue":"(1)","key":"r36","doi-asserted-by":"crossref","first-page":"pp.69","DOI":"10.1016\/j.medengphy.2017.11.005","article-title":"Validation of single-plane fluoroscopy and 2D\/3D shape-matching for quantifying shoulder complex kinematics.","volume":"52","author":"Lawrence","year":"2018","journal-title":"Medical Engineering & Physics"},{"issue":"(11)","key":"r37","doi-asserted-by":"crossref","first-page":"pp.355","DOI":"10.1097\/BRS.0b013e3181715295","article-title":"Measurement of vertebral kinematics using noninvasive image matching method-validation and application.","volume":"33","author":"Wang","year":"2008","journal-title":"Spine"},{"issue":"(3)","key":"r38","doi-asserted-by":"crossref","first-page":"pp.461","DOI":"10.1123\/jab.2013-0112","article-title":"Accuracy and feasibility of dual fluoroscopy and model-based tracking to quantify in vivo hip kinematics during clinical exams.","volume":"30","author":"Kapron","year":"2014","journal-title":"Journal of Applied Biomechanics"},{"issue":"(10)","key":"r39","doi-asserted-by":"crossref","first-page":"pp.2159","DOI":"10.1016\/j.jbiomech.2008.04.021","article-title":"In vivo contact kinematics and contact forces of the knee after total knee arthroplasty during dynamic weight-bearing activities.","volume":"41","author":"Varadarajan","year":"2008","journal-title":"Journal of Biomechanics"},{"issue":"(4)","key":"r40","doi-asserted-by":"crossref","first-page":"pp.888","DOI":"10.1016\/j.gaitpost.2015.03.008","article-title":"Accuracy and feasibility of highspeed dual fluoroscopy and model-based tracking to measure in vivo ankle arthrokinematics.","volume":"41","author":"Wang","year":"2015","journal-title":"Gait & Posture"},{"issue":"(1)","key":"r41","first-page":"pp.1","article-title":"Direct assessment of 3D foot bone kinematics using biplanar X-ray fluoroscopy and an automatic model registration method.","volume":"8","author":"Ito","year":"2015","journal-title":"Journal of Foot and Ankle Research"},{"issue":"(9)","key":"r42","doi-asserted-by":"crossref","first-page":"pp.1303","DOI":"10.1016\/j.medengphy.2011.12.021","article-title":"The accuracy and repeatability of an automatic 2D-3D fluoroscopic image-model registration technique for determining shoulder joint kinematics.","volume":"34","author":"Zhu","year":"2012","journal-title":"Medical Engineering & Physics"},{"issue":"(2004)","key":"r43","first-page":"pp.162","article-title":"Shoulder impingement syndrome.","volume":"15","author":"Fu","year":"1991","journal-title":"A critical review."},{"issue":"(2)","key":"r44","first-page":"pp.1","article-title":"Coraco-humeral distances and correlation to arm rotation: An in vivo 3-dimensional biplane fluoroscopy study.","volume":"1","author":"Brunkhorst","year":"2013","journal-title":"Orthopaedic Journal of Sports Medicine"},{"issue":"(26)","key":"r45","first-page":"pp.1","article-title":"Efficacy of shoulder arthroscopic surgery for thetreatment of rotator cuff injury A protocol of systematic review and meta-analysis.","volume":"99","author":"Zong","year":"2020","journal-title":"Medicine"},{"issue":"(7)","key":"r46","first-page":"pp.1","article-title":"In vivo kinematic analysis of the glenohumeral joint during dynamic full axial rotation and scapular plane full abduction in healthy shoulders.","volume":"25","author":"Kozono","year":"2016","journal-title":"Knee Surgery Sports Traumatology Arthroscopy"},{"issue":"(3)","key":"r47","doi-asserted-by":"crossref","first-page":"pp.371","DOI":"10.1016\/j.jbiomech.2015.12.029","article-title":"Sagittal plane rotation center of lower lumbar spine during a dynamic weight-lifting activity.","volume":"49","author":"Liu","year":"2016","journal-title":"Journal of Biomechanics"},{"issue":"(7)","key":"r48","doi-asserted-by":"crossref","first-page":"pp.1653","DOI":"10.1016\/j.spinee.2015.03.015","article-title":"In-vivo dynamic changes of dimensions in the lumbar intervertebral foramen.","volume":"15","author":"Zhong","year":"2015","journal-title":"Spine Journal"},{"issue":"(11)","key":"r49","doi-asserted-by":"crossref","first-page":"pp.2350","DOI":"10.1007\/s00586-014-3316-9","article-title":"Dynamic motion characteristics of the lower lumbar spine: Implication to lumbar pathology and surgical treatment.","volume":"23","author":"Wu","year":"2014","journal-title":"European Spine Journal"},{"issue":"(4)","key":"r50","doi-asserted-by":"crossref","first-page":"pp.653","DOI":"10.1007\/s00167-010-1327-6","article-title":"Relationship of anterior knee laxity to knee translations during drop landings: A bi-plane fluoroscopy study.","volume":"19","author":"Torry","year":"2011","journal-title":"Knee Surgery Sports Traumatology Arthroscopy Official Journal of the Esska"},{"issue":"(12)","key":"r51","first-page":"pp.18771884","article-title":"Tibiofemoral kinematics and condylar motion during the stance phase of gait.","volume":"42","author":"Kozanek","year":"2009","journal-title":"Journal of Biomechanics"},{"issue":"(1)","key":"r52","first-page":"pp.101106","article-title":"Analysis of in-vivo articular cartilage contact surface of the knee during a step-up motion.","volume":"49","author":"Yin","year":"2017","journal-title":"Clinical Biomechanics"},{"issue":"(3)","key":"r53","doi-asserted-by":"crossref","first-page":"pp.298","DOI":"10.1007\/s00776-009-1325-z","article-title":"In vivo anterior cruciate ligament elongation in response to axial tibial loads.","volume":"14","author":"Hosseini","year":"2009","journal-title":"Journal of Orthopaedic Science Official Journal of the Japanese Orthopaedic Association"},{"issue":"(10)","key":"r54","doi-asserted-by":"crossref","first-page":"pp.1019","DOI":"10.1016\/j.clinbiomech.2011.06.010","article-title":"Relationship of knee shear force and extensor moment on knee translations in females performing drop landings: A biplane fluoroscopy study.","volume":"26","author":"Torry","year":"2011","journal-title":"Clinical Biomechanics"},{"issue":"(5)","key":"r55","doi-asserted-by":"crossref","first-page":"pp.719","DOI":"10.1007\/s00167-010-1336-5","article-title":"In vivo length patterns of the medial collateral ligament during the stance phase of gait.","volume":"19","author":"Liu","year":"2011","journal-title":"Knee Surgery Sports Traumatology Arthroscopy"},{"issue":"(4)","key":"r56","first-page":"pp.881","article-title":"Mechanical loads at the knee joint during deep flexion.","volume":"20","author":"Takeo","year":"2010","journal-title":"Journal of Orthopaedic Research"},{"key":"r57","article-title":"Biomechanics study of the knee joint under high flexion.","volume-title":"Chinese People's Liberation Army Medical College, Doctoral Dissertation.","author":"Qi","year":"2013"},{"issue":"(11)","key":"r58","first-page":"pp.16221627","article-title":"In vivo cartilage contact deformation in the healthy human tibiofemoral joint.","volume":"47","author":"Bingham","year":"2008","journal-title":"Rheumatology"},{"issue":"(7)","key":"r59","first-page":"pp.909916","article-title":"In-vivo time-dependent articular cartilage contact behavior of the tibiofemoral joint.","volume":"18","author":"Hosseini","year":"2010","journal-title":"Osteoarthritis & Cartilage"},{"issue":"(1)","key":"r60","first-page":"pp.1","article-title":"Function of anterior talofibular and calcaneofibular ligaments during in-vivo motion of the ankle joint complex.","volume":"4","author":"De Asla","year":"2009","journal-title":"Journal of Orthopaedic Surgery & Research"},{"issue":"(1)","key":"r61","doi-asserted-by":"crossref","first-page":"pp.128","DOI":"10.1016\/j.jbiomech.2007.07.006","article-title":"Determination of real-time in-vivo cartilage contact deformation in the ankle joint.","volume":"41","author":"Li","year":"2008","journal-title":"Journal of Biomechanics"},{"issue":"(5)","key":"r62","doi-asserted-by":"crossref","first-page":"pp.1019","DOI":"10.1002\/jor.20142","article-title":"Six DOF in vivo kinematics of the ankle joint complex: Application of a combined dual-orthogonal fluoroscopic and magnetic resonance imaging technique.","volume":"24","author":"De Asla","year":"2006","journal-title":"Journal of Orthopaedic Research"},{"key":"r63","doi-asserted-by":"crossref","first-page":"pp.262268","DOI":"10.1016\/j.gaitpost.2019.07.377","article-title":"In vivo kinematics of functional ankle instability patients during the stance phase of walking.","volume":"73","author":"Cao","year":"2019b","journal-title":"Gait Posture"},{"issue":"(11)","key":"r64","first-page":"pp.18171826","article-title":"In vivo 3-dimensional analysis of scapular and glenohumeral kinematics: Comparison of symptomatic or asymptomatic shoulders with rotator cuff tears and healthy shoulders.","volume":"24","author":"Kijima","year":"2015","journal-title":"Journal of Shoulder & Elbow Surgery"},{"issue":"(7)","key":"r65","doi-asserted-by":"crossref","first-page":"pp.1013","DOI":"10.1007\/s00586-009-0936-6","article-title":"Segmental in vivo vertebral motion during functional human lumbar spine activities.","volume":"18","author":"Li","year":"2009","journal-title":"European Spine Journal"},{"issue":"(3)","key":"r66","first-page":"pp.1","article-title":"Six degree-of-freedom knee joint kinematics in obese individuals with knee pain during gait.","volume":"12","author":"Li","year":"2017","journal-title":"Plos One"},{"issue":"(11)","key":"r67","doi-asserted-by":"crossref","first-page":"pp.1236","DOI":"10.1177\/1071100717723128","article-title":"Application of high-speed dual fluoroscopy to study in vivo tibiotalar and subtalar kinematics in patients with chronic ankle instability and asymptomatic control subjects during dynamic activities.","volume":"38","author":"Roach","year":"2017","journal-title":"Foot & Ankle International"},{"issue":"(11)","key":"r68","doi-asserted-by":"crossref","first-page":"pp.2647","DOI":"10.1016\/j.jbiomech.2014.05.016","article-title":"Effects of footwear on threedimensional tibiotalar and subtalar joint motion during running.","volume":"47","author":"Peltz","year":"2014","journal-title":"Journal of Biomechanics"},{"issue":"(1)","key":"r69","doi-asserted-by":"crossref","first-page":"pp.21","DOI":"10.1080\/19424280.2013.834981","article-title":"Do high-top shoes reduce ankle inversion? A dynamic X-ray analysis of aggressive cutting in a high-top and low-top shoe.","volume":"6","author":"Bishop","year":"2014","journal-title":"Footwear Science"}],"container-title":["Journal of Medical Imaging and Health Informatics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ingentaconnect.com\/content\/asp\/jmihi\/2021\/00000011\/00000008\/art00005","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,7,10]],"date-time":"2021-07-10T05:14:34Z","timestamp":1625894074000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ingentaconnect.com\/content\/10.1166\/jmihi.2021.3579"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,8,1]]},"references-count":69,"journal-issue":{"issue":"8","published-print":{"date-parts":[[2021,8,1]]}},"alternative-id":["2156-7018(20210801)11:8L.2067;1-"],"URL":"https:\/\/doi.org\/10.1166\/jmihi.2021.3579","relation":{},"ISSN":["2156-7018"],"issn-type":[{"value":"2156-7018","type":"print"}],"subject":[],"published":{"date-parts":[[2021,8,1]]}}}