41.
|
|
|
42.
|
Modeling and metrological analysis of an X-ray diffractometer for crystal-assisted collimation in particle accelerator
/ Arpaia, Pasquale (Naples U.) ; Gargiulo, Simone (CERN ; Naples U.) ; Gavrikov, Yury (Kurchatov Inst., Moscow) ; Masi, Alessandro (CERN) ; Scandale, Walter (CERN)
A FEM model of a double-crystal diffractometer and its metrological analysis is proposed for a complete characterization of bent crystals involved in the process of particles collimation in the Large Hadron Collider at CERN, in terms of miscut, bending and torsion angles. The model reproduces the laboratory measurement procedure based mainly on a 2D scanning algorithm and a π rad flip of the crystal under test. [...]
2018 - 5 p.
- Published in : J. Phys.: Conf. Ser. 1065 (2018) 072045
Fulltext: PDF;
In : 22nd World Congress of the International Measurement Confederation, Belfast, United Kingdom, 3 - 6 Sep 2018, pp.072045
|
|
|
43.
|
|
|
Crystal Collimation Tests with Pb Ion Beams
/ D'Andrea, Marco (Universita e INFN, Padova (IT)) ; Mirarchi, Daniele (University of Manchester (GB)) ; Redaelli, Stefano (CERN) ; Fomin, Alex (NSC Kharkiv Institute of Physics and Technology (UA)) ; Belli, Eleonora (CERN) ; Salvachua Ferrando, Belen Maria (CERN) ; Nevay, Laurence James (University of London (GB)) ; Rossi, Roberto (Sapienza Universita e INFN, Roma I (IT)) ; Scandale, Walter (CERN) ; Montesano, Simone (Universita e INFN, Bologna (IT)) et al.
During MD4168, performed on November 27th 2018, silicon crystals for a crystal-assisted collimation system were tested. [...]
CERN-ACC-NOTE-2019-0024.
-
2019.
Full text
|
|
|
44.
|
|
|
Operational Aspects of Crystal Collimation with Proton Beams
/ D'Andrea, Marco (Universita e INFN, Padova (IT)) ; Mirarchi, Daniele (University of Manchester (GB)) ; Redaelli, Stefano (CERN) ; Salvachua Ferrando, Belen Maria (CERN) ; Nevay, Laurence James (University of London (GB)) ; Rossi, Roberto (Sapienza Universita e INFN, Roma I (IT)) ; Scandale, Walter (CERN) ; Montesano, Simone (Universita e INFN, Bologna (IT)) ; Galluccio, Francesca (Universita e sezione INFN di Napoli (IT)) ; Serrano Galvez, Pablo (Universidad de Oviedo (ES)) et al.
During MD4167, performed on September 12th 2018, silicon crystals for a crystal-assisted collimation system were tested, with particular focus on operational aspects such as evaluation of cleaning performances and deployment during dynamical phases of the machine. [...]
CERN-ACC-NOTE-2019-0023.
-
2019.
Full text
|
|
|
45.
|
|
|
Crystal Collimation Tests with Proton Beams
/ D'Andrea, Marco (Universita e INFN, Padova (IT)) ; Mirarchi, Daniele (University of Manchester (GB)) ; Redaelli, Stefano (CERN) ; Salvachua Ferrando, Belen Maria (CERN) ; Nevay, Laurence James (University of London (GB)) ; Rossi, Roberto (Sapienza Universita e INFN, Roma I (IT)) ; Scandale, Walter (CERN) ; Montesano, Simone (Universita e INFN, Bologna (IT)) ; Galluccio, Francesca (Universita e sezione INFN di Napoli (IT)) ; Serrano Galvez, Pablo (Universidad de Oviedo (ES)) et al.
During MD3327, performed in two steps on June 14th and July 27th 2018, silicon crystals for a crystal-assisted collimation system were tested, with particular focus on the newly installed crystal on the horizontal plane of Beam 2. [...]
CERN-ACC-NOTE-2019-0022.
-
2019.
Full text
|
|
|
46.
|
Results on Multiple Coulomb Scattering from 12 and 20 GeV electrons on Carbon targets
/ MUonE Collaboration
Multiple scattering effects of 12 and 20 GeV electrons on 8 and 20 mm thickness carbon targets have been studied with high-resolution silicon microstrip detectors of the UA9 apparatus at the H8 line at CERN. Comparison of the scattering angle between data and GEANT4 simulation shows excellent agreement in the core of the distributions leaving some residual disagreement in the tails..
arXiv:1905.11677.-
2020-01-16 - 15 p.
- Published in : JINST 15 (2020) P01017
Fulltext: PDF;
|
|
|
47.
|
|
|
48.
|
Commissioning and operation of the Cherenkov detector for proton Flux Measurement of the UA9 Experiment
/ Addesa, F.M. (INFN, Rome) ; Burmistrov, L. (Orsay, LAL) ; Breton, D. (Orsay, LAL) ; Cavoto, G. (INFN, Rome ; Rome U.) ; Chaumat, V. (Orsay, LAL) ; Dubos, S. (Orsay, LAL) ; Esposito, L. (CERN) ; Galluccio, F. (INFN, Naples) ; Garattini, M. (CERN ; Imperial Coll., London) ; Iacoangeli, F. (INFN, Rome) et al.
The UA9 Experiment at CERN-SPS investigates channeling processes in bent silicon crystals with the aim to manipulate hadron beams. Monitoring and characterization of channeled beams in the high energy accelerators environment ideally requires in-vacuum and radiation hard detectors. [...]
arXiv:1904.06178.-
2019-12-01 - 25 p.
- Published in : Nucl. Instrum. Methods Phys. Res., A 946 (2019) 162513
Fulltext: PDF;
|
|
|
49.
|
A smart adjustable Inelastic Nuclear Interactions counter based on compact Arduino control system and readout
/ Iacoangeli, F (INFN, Rome) ; Natochii, A (CERN) ; Gavrikov, Y (St. Petersburg, INP) ; Garattini, M (CERN) ; Cavoto, G (INFN, Rome) ; Addesa, F (INFN, Rome) ; Montesano, S (CERN) ; Scandale, W (CERN)
We realized an embedded system, easy to install and to calibrate, remote controlled and adjustable in order to equip an extracted beam line of a precise Inelastic Nuclear Interactions (INI) counter. The system made up of the Nuclear Interaction Detector (NID) and of a motorized, two arms, translation stage which allows precise positioning and scan of different inelastic nuclear scattering angles. [...]
2018 - 4 p.
- Published in : 10.1109/NSSMIC.2017.8532668
In : 2017 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC 2017), Atlanta, Georgia, USA, 21 - 28 Oct 2017, pp.8532668
|
|
|
50.
|
Characterization of the quartz surface quality with $\beta$-source
/ Natochii, A (Taras Shevchenko U. ; Orsay, LAL) ; Addesa, F (INFN, Rome) ; Bezshyyko, O (Taras Shevchenko U.) ; Breton, D (Orsay, LAL) ; Burmistrov, L (Orsay, LAL) ; Chaumat, V (Orsay, LAL) ; Cavoto, G (INFN, Rome) ; Dubos, S (Orsay, LAL) ; Garattini, M (CERN) ; Gavrikov, Y (CERN) et al.
We present a method for characterizing the quality of the Cherenkov quartz radiator. It is based on the scanning with $^{90}$Sr radioactive source (standard deviation is 1.17 mm) of the radiator surface and measurements of the Cherenkov light rate and amplitude, detected by the PMT attached to the quartz bars. [...]
2018 - 3 p.
- Published in : 10.1109/NSSMIC.2017.8532945
In : 2017 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC 2017), Atlanta, Georgia, USA, 21 - 28 Oct 2017, pp.8532945
|
|