Notifications
You must be signed in to change notification settings - Fork 343
/
DOWN-TELEMETRY_PROGRAM.agc
466 lines (438 loc) · 17.9 KB
/
DOWN-TELEMETRY_PROGRAM.agc
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
### FILE="Main.annotation"
## Copyright: Public domain.
## Filename: DOWN_TELEMETRY_PROGRAM.agc
## Purpose: Part of the source code for Colossus, build 249.
## It is part of the source code for the Command Module's (CM)
## Apollo Guidance Computer (AGC), for Apollo 9.
## Assembler: yaYUL
## Reference: Starts on p. 1063.
## Contact: Ron Burkey <info@sandroid.org>.
## Website: www.ibiblio.org/apollo.
## Mod history: 08/28/04 RSB. Adapted from corresponding Luminary 131 file.
## 2010-10-24 JL Indentation fixes.
## 2017-01-06 RSB Page numbers now agree with those on the
## original harcopy, as opposed to the PDF page
## numbers in 1701.pdf.
## 2017-01-07 RSB Cross-diff'd comment text (not whitespace)
## vs the already-proofed corresponding Colossus
## 237 and Comanche 55 source-code files
## and corrected errors found.
## 2017-03-15 RSB Comment-text fixes identified in 5-way
## side-by-side diff of Luminary 69/99/116/131/210.
## The contents of the "Colossus249" files, in general, are transcribed
## from a scanned copy of the program listing. Notations on this
## document read, in part:
##
## Assemble revision 249 of AGC program Colossus by NASA
## 2021111-041. October 28, 1968.
##
## This AGC program shall also be referred to as
## Colossus 1A
##
## Prepared by
## Massachusetts Institute of Technology
## 75 Cambridge Parkway
## Cambridge, Massachusetts
## under NASA contract NAS 9-4065.
##
## Refer directly to the online document mentioned above for further information.
## Please report any errors (relative to the scanned pages) to info@sandroid.org.
##
## In some cases, where the source code for Luminary 131 overlaps that of
## Colossus 249, this code is instead copied from the corresponding Luminary 131
## source file, and then is proofed to incorporate any changes.
## Page 1063
# PROGRAM NAME- DOWN TELEMETRY PROGRAM
# MOD NO.- 0 TO COMPLETELY REWRITE THE DOWN TELEMETRY PROGRAM AND DOWNLINK ERASABLE DUMP PROGRAM FOR THE
# PURPOSE OF SAVING APPROXIMATELY 150 WORDS OF CORE STORAGE.
# THIS CHANGE REQUIRES AN ENTIRELY NEW METHOD OF SPECIFYING DOWNLINK LISTS. REFER TO DOWNLINK
# LISTS LOG SECTION FOR MORE DETAILS. HOWEVER THIS CHANGE WILL NOT AFFECT THE GROUND PROCESSING
# OF DOWN TELEMETRY DATA.
# MOD BY- KILROY, SMITH, DEWITT
# DATE- 02 OCT 67
# AUTHORS- KILROY, SMITH, DEWITT, DEWOLF, FAGIN
# LOG SECTION- DOWN-TELEMETRY PROGRAM
#
# FUNCTIONAL DESCRIPTION- THIS ROUTINE IS INITIATED BY TELEMETRY END
# PULSE FROM THE DOWNLINK TELEMETRY CONVERTER. THIS PULSE OCCURS
# AT 50 TIMES PER SEC (EVERY 20 MS) THEREFORE DODOWNTM IS
# EXECUTED AT THESE RATES. THIS ROUTINE SELECTS THE APPROPRIATE
# AGC DATA TO BE TRANSMITTED DOWNLINK AND LOADS IT INTO OUTPUT
# CHANNELS 34 AND 35. THE INFORMATION IS THEN GATED OUT FROM THE
# LGC IN SERIAL FASHION.
#
# THIS PROGRAM IS CODED FOR A 2 SECOND DOWNLIST. SINCE DOWNRUPTS
# OCCUR EVERY 20 MS AND 2 AGC COMPUTER WORDS CAN BE PLACED IN
# CHANNELS 34 AND 35 DURING EACH DOWNRUPT THE PROGRAM IS CAPABLE
# OF SENDING 200 AGC WORDS EVERY 2 SECONDS.
#
# CALLING SEQUENCE- NONE
# PROGRAM IS ENTERED VIA TCF DODOWNTM WHICH IS EXECUTED AS A
# RESULT OF A DOWNRUPT. CONTROL IS RETURNED VIA TCF RESUME WHICH
# IN EFFECT IS A RESUME.
#
# SUBROUTINES CALLED- NONE
#
# NORMAL EXIT MODE- TCF RESUME
#
# ALARM OR ABORT EXIT MODE- NONE
#
# RESTART PROTECTION:
# ON A FRESH START AND RESTART THE 'STARTSUB' SUBROUTINE WILL INITIALIZE THE DOWNLIST POINTER (ACTUALLY
# DNTMGOTO) TO THE BEGINNING OF THE CURRENT DOWNLIST (I.E. CURRENT CONTENTS OF DNLSTADR). THIS HAS THE
# EFFECT OF IGNORING THE REMAINDER OF THE DOWNLIST WHICH THE DOWN-TELEMETRY PROGRAM WAS WORKING ON WHEN
# THE RESTART (OR FRESH START) OCCURRED AND RESUME DOWN TELEMETRY FROM THE BEGINNING OF THE CURRENT
# DOWNLIST.
#
# ALSO OF INTEREST IS THE FACT THAT ON A RESTART THE AGC WILL ZERO DOWNLINK CHANNELS 13, 34 AND 35.
#
# DOWNLINK LIST SELECTION:
# THE APPROPRIATE DOWNLINK LISTS ARE SELECTED BY THE FOLLOWING:
# 1. FRESH START
# 2. V37EXXE WHERE XX = THE MAJOR MODE BEING SELECTED.
# 3. UPDATE PROGRAM (P27)
# 4. NON-V37 SELECTABLE TYPE PROGRAMS (E.G. AGS INITIALIZATION (SUNDANCE, LUMINARY) AND P61-P62
# TRANSITION (COLOSSUS) ETC.).
#
# DOWNLINK LIST RULES AND LIMITATIONS:
# READ SECTION(S) WHICH FOLLOW 'DEBRIS' WRITEUP.
#
# OUTPUT- EVERY 2 SECONDS 100 DOUBLE PRECISION WORDS (I.E. 200 LGC
# COMPUTER WORDS) ARE TRANSMITTED VIA DOWNLINK.
#
# ERASABLE INITIALIZATION REQUIRED- NONE
# 'DNTMGOTO' AND 'DNLSTADR' ARE INITIALIZED BY THE FRESH START PROGRAM.
#
# DEBRIS (ERASABLE LOCATIONS DESTROYED BY THIS PROGRAM)-
# LDATALST, DNTMBUFF TO DNTMBUFF +21D, TMINDEX, DNQ.
## Page 1064
## No source on this page of the original assembly listing.
## Page 1065
# DODOWNTM IS ENTERED EVERY 20 MS BY AN INTERRUPT TRIGGERED BY THE
# RECEIPT OF AN ENDPULSE FROM THE SPACECRAFT TELEMETRY PROGRAMMER.
#
# NOTES REGARDING DOWNLINK LISTS ASSOCIATED WITH THIS PROGRAM:
# 1. DOWNLISTS. - DOWNLISTS MUST BE COMPILED IN THE SAME BANK AS THE
# DOWN-TELEMETRY PROGRAM. THIS IS DONE FOR EASE OF CODING, FASTER
# EXECUTION.
# 2. EACH DOWNLINK LIST CONSISTS OF A CONTROL LIST AND A NUMBER OF
# SUBLISTS.
# 3. A SUBLIST REFERS TO A SNAPSHOT OR DATA COMMON TO THE SAME OR OTHER
# DOWNLINK LISTS. ANY SUBLIST CONTAINING COMMON DATA NEEDS TO BE
# CODED ONLY ONCE FOR THE APPLICABLE DOWNLINK LISTS.
# 4. SNAPSHOT SUBLISTS REFER SPECIFICALLY TO HOMOGENOUS DATA WHICH MUST BE
# SAVED IN A BUFFER DURING ONE DOWNRUPT.
# 5. THE 1DNADR FOR THE 1ST WORD OF SNAPSHOT DATA IS FOUND AT THE END
# OF EACH SNAPSHOT SUBLIST, SINCE THE PROGRAM CODING SENDS THIS DP WORD
# IMMEDIATELY AFTER STORING THE OTHERS IN THE SNAPSHOT BUFFER.
# 6. ALL LISTS ARE COMBINATIONS OF CODED ERASABLE ADDRESS CONSTANTS
# CREATED FOR THE DOWNLIST PROGRAM.
# A. 1DNADR 1-WORD DOWNLIST ADDRESS.
# SAME AS ECADR, BUT USED WHEN THE WORD ADDRESSED IS THE LEFT
# HALF OF A DOUBLE-PRECISION WORD FOR DOWN TELEMETRY.
# B. 2DNADR - 6DNADR N-WORD DOWNLIST ADDRESS, N = 2 - 6.
# SAME AS 1DNADR, BUT WITH THE 4 UNUSED BITS OF THE ECADR FORMAT
# FILLED IN WITH 0001-0101. USED TO POINT TO A LIST OF N DOUBLE-
# PRECISION WORDS, STORED CONSECUTIVELY, FOR DOWN TELEMETRY.
# C. DNCHAN DOWNLIST CHANNEL ADDRESS.
# SAME AS 1DNADR, BUT WITH PREFIX BITS 0111. USED TO POINT TO
# A PAIR OF CHANNELS FOR DOWN TELEMETRY.
# D. DNPTR DOWN TELEMETRY SUBLIST POINTER.
# SAME AS CAF BUT TAGGED AS A CONSTANT. USED IN CONTROL LIST TO POINT TO A SUBLIST.
# CAUTION --- A DNPTR CANNOT BE USED IN A SUBLIST.
# 7. THE WORD ORDER CODE IS SET TO ZERO AT THE BEGINNING OF EACH DOWNLIST (I.E. CONTROL LIST) AND WHEN
# A '1DNADR TIME2' IS DETECTED IN THE CONTROL LIST (ONLY).
# 8. IN THE SNAPSHOT SUBLIST ONLY, THE DNADR'S CANNOT POINT TO THE FIRST WORD OF ANY EBANK.
#
# DOWNLINK LIST RESTRICTIONS:
# (THE FOLLOWING POINTS MAY BE LISTED ELSEWHERE BUT ARE LISTED HERE SO IT IS CLEAR THAT THESE THINGS CANNOT BE
# DONE)
# 1. SNAPSHOT DOWNLIST:
# (A) CANNOT CONTAIN THE FOLLOWING ECADRS (I.E. 1DNADR'S): 0, 400, 1000, 1400, 2000, 2400, 3000, 3400.
# (B) CAN CONTAIN ONLY 1DNADR'S
# 2. ALL DOWNLINKED DATA (EXCEPT CHANNELS) IS PICKED UP BY A <DCA<SO DOWNLINK LISTS CANNOT CONTAIN THE
# EQUIVALENT OF THE FOLLOWING ECADRS (I.E. IDNADRS): 377, 777, 1377, 1777, 2377, 27777, 3377, 3777.
# (NOTE: THE TERM EQUIVALENT ' MEANT THAT THE IDNADR TO 6DNADR WILL BE PROCESSED LIKE 1 TO 6 ECADRS)
# 3. CONTROL LISTS AND SUBLISTS CANNOT HAVE ENTRIES = OCTAL 00000 OR OCTAL 77777
## Page 1066
# 4. THE '1DNADR TIME2' WHICH WILL CAUSE THE DOWNLINK PROGRAM TO SET THE WORDER CODE TO 3 MUST APPEAR IN THE
# CONTROL SECTION OF THE DOWNLIST.
# 5. 'DNCHAN 0' CANNOT BE USED.
# 6. 'DNPTR 0' CANNOT BE USED.
# 7. DNPTR CANNOT APPEAR IN A SUBLIST.
#
# EBANK SETTINGS
# IN THE PROCESS OF SETTING THE EBANK (WHEN PICKING UP DOWNLINK DATA) THE DOWN TELEMETRY PROGRAM PUTS
# 'GARBAGE' INTO BITS15-12 OF EBANK. HUGH BLAIR-SMITH WARNS US THAT BITS15-12 OF EBANK MAY BECOME
# SIGNIFICANT SOMEDAY IN THE FUTURE. IF/WHEN THAT HAPPENS, THE PROGRAM SHOULD INSURE (BY MASKING ETC.)
# THAT BITS 15-12 OF EBANK ARE ZERO.
#
# INITIALIZATION REQUIRED- TO INTERRUPT CURRENT LIST AND START A NEW ONE..
# 1. ADRES OF DOWNLINK LIST INTO DNLSTADR
# 2. NEGONE INTO SUBLIST
# 3. NEGONE INTO DNECADR
BANK 22
SETLOC DOWNTELM
BANK
EBANK= DNTMBUFF
COUNT 05/DPROG
DODOWNTM TS BANKRUPT
EXTEND
QXCH QRUPT # SAVE Q
CA BIT7 # SET WORD ORDER CODE TO 1. EXCEPTION- AT
EXTEND # THE BEGINNING OF EACH LIST THE WORD
WOR CHAN13 # CODE WILL BE SET BACK TO 0.
TC DNTMGOTO # GOTO APPROPRIATE PHASE OF PROGRAM
DNPHASE1 CA NEGONE # INITIALIZE ALL CONTROL WORDS
TS SUBLIST # WORDS TO MINUS ONE
TS DNECADR
CA LDNPHAS2 # SET DNTMGOTO =O ALL SUBSEQUENT DOWNRUPTS
TS DNTMGOTO # GO TO DNPHASE2
TCF NEWLIST
DNPHASE2 CCS DNECADR # SENDING OF DATA IN PROGRESS
DODNADR TC FETCH2WD # YES - THEN FETCH THE NEXT 2 SP WORDS
MINTIME2 -1DNADR TIME2 # NEGATIVE OF TIME2 1DNADR
TCF +1 # (ECADR OF 3776 + 74001 = 77777)
CCS SUBLIST # IS THE SUBLIST IN CONTROL
## Page 1067
TCF NEXTINSL # YES
DNADRDCR OCT 74001 # DNADR COUNT AND ECADR DECREMENTER
CHKLIST CA CTLIST
EXTEND
BZMF NEWLIST # IT WILL BE NEGATIVE AT END OF LIST
TCF NEXTINCL
NEWLIST INDEX DNLSTCOD
CA DNTABLE # INITIALIZE CTLIST WITH
TS CTLIST # STARTING ADDRESS OF NEW LIST
CS DNLSTCOD
TCF SENDID +3
NEXTINCL INDEX CTLIST
CA 0
CCS A
INCR CTLIST # SET POINTER TO PICK UP NEXT CTLIST WORD
TCF +4 # ON NEXT ENTRY TO PROG. (A SHOULD NOT =0)
XCH CTLIST # SET CTLIST TO NEGATIVE AND PLACE(CODING)
COM # UNCOMPLEMENTED DNADR INTO A. (FOR LA)
XCH CTLIST # (ST IN )
+4 INCR A # (CTLIST)
TS DNECADR # SAVE DNADR
AD MINTIME2 # TEST FOR TIME2 (NEG. OF ECADR)
CCS A
TCF SETWO +1 # DON'T SET WORD ORDER CODE
MINB1314 OCT 47777 # MINUS BIT 13 AND 14 (CAN'T GET HERE)
TCF SETWO +1 # DON'T SET WORD ORDER CODE
SETWO TC WOZERO # GO SET WORD ORDER CODE TO ZERO.
+1 CA DNECADR # RELOAD A WITH THE DNADR.
+2 AD MINB1314 # IS THIS A REGULAR DNADR?
EXTEND
BZMF FETCH2WD # YES. (A MUST NEVER BE ZERO)
AD MINB12 # NO- IS IT A POINTER (DNPTR) OR A
EXTEND # CHANNEL(DNCHAN)
BZMF DODNPTR # IT'S A POINTER. (A MUST NEVER BE ZERO)
DODNCHAN TC 6 # (EXECUTED AS EXTEND) IT S A CHANNEL
INDEX DNECADR
INDEX 0 -4000 # (EXECUTED AS READ)
TS L
TC 6 # (EXECUTED AS EXTEND)
INDEX DNECADR
INDEX 0 -4001 # (EXECUTED AS READ)
TS DNECADR # SET DNECADR
CA NEGONE # TO MINUS
XCH DNECADR # WHILE PRESERVING A.
TCF DNTMEXIT # GO SEND CHANNELS
WOZERO CS BIT7
EXTEND
## Page 1068
WAND CHAN13 # SET WORD ORDER CODE TO ZERO
TC Q # RETURN TO CALLER
DODNPTR INDEX DNECADR # DNECADR CONTAINS ADRES OF SUBLIST
0 0 # CLEAR AND ADD LIST ENTRY INTO A.
CCS A # IS THIS A SNAPSHOT SUBLIST
CA DNECADR # NO, IT IS A REGULAR SUBLIST.
TCF DOSUBLST # A MUST NOT BE ZERO.
XCH DNECADR # YES, IT IS A SNAPSHOT SUBLIST.
TS SUBLIST # C(DNECADR) INTO SUBLIST
CAF ZERO # A INTO A
XCH TMINDEX # (NOTE.. TMINDEX = DNECADR)
# THE FOLLOWING CODING (FROM SNAPLOOP TO SNAPEND) IS FOR THE PURPOSE OF TAKING A SNAPSHOT OF 12 DP REGISTERS.
# THIS IS DONE BY SAVING 11 DP REGISTERS IN DNTMBUFF AND SENDING THE FIRST DP WORD IMMEDIATELY.
# THE SNAPSHOT PROCESSING IS THE MOST TIME CONSUMING AND THEREFORE THE CODING AND LIST STRUCTURE WERE DESIGNED
# TO MINIMIZE TIME. THE TIME OPTIMIZATION RESULTS IN RULES UNIQUE TO THE SNAPSHOT PORTION OF THE DOWNLIST.
# THESE RULES ARE ......
# 1. ONLY 1DNADR'S CAN APPEAR IN THE SNAPSHOT SUBLIST
# 2. THE 1DNADR'S CANNOT REFER TO THE FIRST LOCATION IN ANY BANK.
SNAPLOOP TS EBANK # SET EBANK
MASK LOW8 # ISOLATE RELATIVE ADDRESS
EXTEND
INDEX A
EBANK= 1401
DCA 1401 # PICK UP 2 SNAPSHOT WORDS.
EBANK= DNTMBUFF
INDEX TMINDEX
DXCH DNTMBUFF # STORE 2 SNAPSHOT WORDS IN BUFFER
INCR TMINDEX # SET BUFFER INDEX FOR NEXT 2 WORDS.
INCR TMINDEX
SNAPAGN INCR SUBLIST # SET POINTER TO NEXT 2 WORDS OF SNAPSHOT
INDEX SUBLIST
0 0 # = CA SSSS (SSSS = NEXT ENTRY IN SUBLIST)
CCS A # TEST FOR LAST TWO WORDS OF SNAPSHOT.
TCF SNAPLOOP # NOT LAST TWO.
LDNPHAS2 GENADR DNPHASE2
TS SUBLIST # YES, LAST. SAVE A.
CA NEGONE # SET DNECADR AND
TS DNECADR # SUBLIST POINTERS
XCH SUBLIST # TO NEGATIVE VALUES.
TS EBANK
MASK LOW8
EXTEND
INDEX A
EBANK= 1401
## Page 1069
DCA 1401 # PICK UP FIRST 2 WORDS OF SNAPSHOT.
EBANK= DNTMBUFF
SNAPEND TCF DNTMEXIT # NOW GO SEND THEM.
FETCH2WD CA DNECADR
TS EBANK # SET EBANK
MASK LOW8 # ISOLATE RELATIVE ADDRESS
TS L
CA DNADRDCR # DECREMENT COUNT AND ECADR
ADS DNECADR
EXTEND
INDEX L
EBANK= 1400
DCA 1400 # PICK UP 2 DATA WORDS
EBANK= DNTMBUFF
TCF DNTMEXIT # NOW GO SEND THEM.
DOSUBLST TS SUBLIST # SET SUBLIST POINTER
NEXTINSL INDEX SUBLIST
0 0 # = CA SSSS (SSSS = NEXT ENTRY IN SUBLIST)
CCS A # IS IT THE END OF THE SUBLIST
INCR SUBLIST # NO-
TCF +4
TS SUBLIST # SAVE A.
CA NEGONE # SET SUBLIST TO MINUS
XCH SUBLIST # RETRIEVE A.
+4 INCR A
TS DNECADR # SAVE DNADR
TCF SETWO +2 # GO USE COMMON CODING (PROBLEMS WOULD
# OCCUR IF THE PROGRAM ENCOUNTERED A
# DNPTR NOW)
DNTMEXIT EXTEND # DOWN-TELEMETRY EXIT
WRITE DNTM1 # TO SEND A + L TO CHANNELS 34 + 35
CA L # RESPECTIVELY
TMEXITL EXTEND
WRITE DNTM2
TMRESUME TCF RESUME # EXIT TELEMETRY PROGRAM VIA RESUME.
MINB12 EQUALS -1/8
DNECADR EQUALS TMINDEX
CTLIST EQUALS LDATALST
SUBLIST EQUALS DNQ
## Page 1070
# SUBROUTINE NAME- DNDUMP
#
# FUNCTIONAL DESCRIPTION - TO SEND(DUMP) ALL ERASABLE STORAGE 'N' TIMES.(N = 1 TO 4). BANKS ARE SENT ONE AT A TIME
# EACH BANK IS PRECEEDED BY AN ID WORD, SYNCH BITS, ECADR AND TIME1 FOLLOWED BY THE 256D WORDS OF EACH
# EBANK. EBANKS ARE DUMPED IN ORDER(I.E. EBANK 0 FIRST, THEN EBANK1 ETC.)
#
# CALLING SEQUENCE- THE GROUND OR ASTRONAUT BY KEYING V74E CAN INITIALIZE THE DUMP.
# AFTER KEYING IN V74E THE CURRENT DOWNLIST WILL BE IMMEDIATELY TERMINATED AND THE DOWNLINK ERASABLE DUMP
# WILL BEGIN.
#
# ONCE INITIATED THE DOWNLINK ERASABLE DUMP CAN BE TERMINATED (AND INTERRUPTED DOWNLIST REINSTATED) ONLY
# BY THE FOLLOWING:
#
# 1. A FRESH START
# 2. COMPLETION OF ALL DOWNLINK DUMPS REQUESTED (ACCORDING TO BITS SET IN DUMPCNT). NOTE THAT DUMPCNT
# CAN BE ALTERED BY A V21N01.
# 3. AND INVOLUNTARILY BY A RESTART.
#
# NORMAL EXIT MODE- TCF DNPHASE1
#
# ALARM OR ABORT MODE- NONE
#
# *SUBROUTINES CALLED- NONE.
#
# ERASABLE INITIALIZATION REQUIRED-
# DUMPCNT OCT 20000 IF 4 COMPLETE ERASABLE DUMPS ARE DESIRED
# DUMPCNT OCT 10000 IF 2 COMPLETE ERASABLE DUMPS ARE DESIRED
# DUMPCNT OCT 04000 IF 1 COMPLETE ERASABLE DUMP IS DESIRED
#
# DEBRIS- DUMPLOC, DUMPSW, DNTMGOTO, EBANK AND CENTRAL REGISTERS
#
# TIMING- TIME (IN SECS) = ((NO.DUMPS)*(NO.EBANKS)*(WDSPEREBANK + NO.IDWDS)) / NO.WDSPERSEC
# TIME (IN SECS) = ( 4 )*( 8 )*( 256 + 4 ) / 100
# THUS TIME (IN SECS TO SEND DUMP OF ERASABLE 4 TIMES VIA DOWNLINK) = 83.2 SECONDS
#
# STRUCTURE OF ONE EBANK AS IT IS SENT BY DOWNLINK PROGRAM-
# (REMINDER- THIS ONLY DESCRIBES ONE OF THE 8 EBANKS X 4 (DUMPS) = 32 EBANKS WHICH WILL BE SENT BY DNDUMP)
#
# DOWNLIST W
# WORD TAKEN FROM CONTENTS OF EXAMPLE O COMMENTS
# 1 ERASID 0177X 0 DOWNLIST I.D. FOR DOWNLINK ERASABLE DUMP (X=7 CSM, 6 LM)
# 2 LOWIDCOD 77340 1 DOWNLINK SYNCH BITS. (SAME ONE USED IN ALL OTHER DOWNLISTS)
# 3 DUMPLOC 13400 1 (SEE NOTES ON DUMPLOC) 1 = 3RD ERAS DUMP, 3400=ECADR OF 5TH WD
# 4 TIME1 14120 1 TIME IN CENTISECONDS
# 5 FIRST WORD OF EBANK X 03400 1 IN THIS EXAMPLE THIS WORD = CONTENTS OF E7,1400 (ECADR 3400)
# 6 2ND WORD OF EBANK X 00142 1 IN THIS EXAMPLE THIS WORD = CONTENTS OF E7,1401 (ECADR 3401)
# 7 3RD WORD OF EBANK X 00142 1 IN THIS EXAMPLE THIS WORD = CONTENTS OF E7,1402 (ECADR 3402)
# . 1
# . 1
# . 1
# 260D 256TH WORD OF EBANK X 03777 1 IN THIS EXAMPLE THIS WORD = CONTENTS OF E7,1777 (ECADR 3777)
#
# NOTE- DUMPLOC CONTAINS THE COUNTER AND ECADR FOR EACH WORD BEING SENT.
# THE BIT STRUCTURE OF DUMPLOC IS FOLLOWS---
# X = NOT USED
# X ABC EEE RRRRRRRR ABC = ERASABLE DUMP COUNTER (I.E. ABC = 0,1,2 OR 3 WHICH MEANS THAT
# COMPLETE ERASABLE DUMP NUMBER 1,2,3 OR 4 RESPECTIVELY IS IN PROGRESS)
# EEE = EBANK BITS
# RRRRRRRR = RELATIVE ADDRESS WITHIN AN EBANK.
## Page 1071
DNDUMPI CA ZERO # INITIALIZE DOWNLINK
TS DUMPLOC # ERASABLE DUMP
+2 TC SENDID # GO SEND ID AND SYNCH BITS
CA LDNDUMP1 # SET DNTMGOTO
TS DNTMGOTO # TO LOCATION FOR NEXT PASS
CA TIME1 # PLACE TIME1
XCH L # INTO L
CA DUMPLOC # AND ECADR OF THIS EBANK INTO A
TCF DNTMEXIT # SEND DUMPLOC AND TIME1
LDNDUMP ADRES DNDUMP
LDNDUMP1 ADRES DNDUMP1
DNDUMP CA TWO # INCREMENT ECADR IN DUMPLOC
ADS DUMPLOC # TO NEXT DP WORD TO BE
MASK LOW8 # DUMPED AND SAVE IT.
CCS A # IS THIS THE BEGINNING OF A NEW EBANK
TCF DNDUMP2 # NO- THEN CONTINUE DUMPING
CA DUMPLOC # YES- IS THIS THE END OF THE
MASK DUMPCNT # N TH(N = 1 TO 4) COMPLETE ERASABLE
MASK PRIO34 # DUMP(BIT14 FOR 4, BIT13 FOR 2 OR BIT12
CCS A # FOR 1 COMPLETE ERASABLE DUMP(S)).
TCF DNPHASE1 # YES- START SENDING INTERRUPTED DOWNLIST
# AGAIN
TCF DNDUMPI +2 # NO- GO BACK AND INITIALIZE NEXT BANK
DNDUMP1 CA LDNDUMP # SET DNTMGOTO
TS DNTMGOTO # FOR WORDS 3 TO 256D OF CURRENT EBANK
DNDUMP2 CA DUMPLOC
TS EBANK # SET EBANK
MASK LOW8 # ISOLATE RELATIVE ADDRESS.
TS Q # (NOTE: MASK INSTRUCTION IS USED TO PICK
CA NEG0 # UP ERASABLE REGISTERS SO THAT EDITING
TS L # REGISTERS 20-23 WILL NOT BE ALTERED.)
INDEX Q
EBANK= 1400 # PICK UP LOW ORDER REGISTER OF PAIR
MASK 1401 # OF ERASABLE REGISTERS.
XCH L
INDEX Q # PICK UP HIGH ORDER REGISTER OF PAIR
MASK 1400 # OF ERASABLE REGISTERS.
EBANK= DNTMBUFF
TCF DNTMEXIT # GO SEND THEM
SENDID EXTEND # ** ENTRANCE USED BY ERASABLE DUMP PROG. **
QXCH DNTMGOTO # SET DNTMGOTO SO NEXT TIME PROG WILL GO
CAF ERASID # TO LOCATION FOLLOWING :TC SENDID:
TS L # ** ENTRANCE USED BY REGULAR DOWNLINK PG **
## Page 1072
TC WOZERO # GO SET WORD ORDER CODE TO ZERO
CAF LOWIDCOD # PLACE SPECIAL ID CODE INTO L
XCH L # AND ID BACK INTO A
TCF DNTMEXIT # SEND DOWNLIST ID CODE(S).