Finite element simulation study on wear under pantograph-catenary system with electric current
Y Lin, M Wu, X Ju, W Lin, DR Ma… - 2020 IEEE International …, 2020 - ieeexplore.ieee.org
The pantograph and the contact line constitute a pair of special friction pairs, between which
there are mechanical wear caused by friction and electrical wear under the action of strong …
there are mechanical wear caused by friction and electrical wear under the action of strong …
Research of RBF-PID control in maglev system
D Ma, M Song, P Yu, J Li - Symmetry, 2020 - mdpi.com
Control of the maglev system is one of the most significant technologies of the maglev train.
The common proportion integration differentiation (PID) method, which has fixed control …
The common proportion integration differentiation (PID) method, which has fixed control …
Classification of partial discharge severities of ceramic insulators based on texture analysis of UV pulses
D Ma, L Jin, J He, K Gao - High Voltage, 2021 - Wiley Online Library
Inspection of partial discharge before contamination flashover is of great importance for
preventing exterior insulation accidents. In this study, a new method for identification of …
preventing exterior insulation accidents. In this study, a new method for identification of …
Analysis of Ultraviolet Characteristics of Partial Discharge for Insulators
D Ma, K Gao, H Jin, T Jiang, Y Lin… - 2020 IEEE International …, 2020 - ieeexplore.ieee.org
Partial discharge detection before insulator flashover plays a significant role in external
insulation fault diagnosis. Ultraviolet (UV) detection has the advantages of non-contact …
insulation fault diagnosis. Ultraviolet (UV) detection has the advantages of non-contact …
On some congruences involving Apéry-like numbers Sn
GS Mao, D Li, X Ma - Journal of Difference Equations and …, 2023 - Taylor & Francis
In this paper, we mainly prove some congruences involving Apéry-like numbers S n = ∑ k =
0 n ( n k ) ( 2 k k ) ( 2 n − 2 k n − k ) : Let p>3 be a prime. Then S p ≡ S 1 + ( − 1 ) ( p − 1 ) / 2 …
0 n ( n k ) ( 2 k k ) ( 2 n − 2 k n − k ) : Let p>3 be a prime. Then S p ≡ S 1 + ( − 1 ) ( p − 1 ) / 2 …
Evaluation of Surface Discharge of Polluted Insulator Based on Optical Emission Spectroscopy Measurements
L Jin, D Ma, Z Yuan, G Zhou… - IEEE Transactions on …, 2023 - ieeexplore.ieee.org
The detection of polluted insulator discharge in humid environments is crucial for power
system examination. In this article, we propose novel classification and evaluation methods by …
system examination. In this article, we propose novel classification and evaluation methods by …
Research on operational state monitoring of maglev train based on machine learning
D Ma, Y Peichang, J Li - 2019 Chinese Automation Congress …, 2019 - ieeexplore.ieee.org
Maglev train is a modern rail vehicle with low energy consumption, low noise and high
comfort. Due to the monitoring of the running state of the train during the operation and …
comfort. Due to the monitoring of the running state of the train during the operation and …
Discrimination of Insulator Discharge Phenomena Based on Characteristics of UV Pulse
D Ma, X Qiao, H Jin, L Jin… - 2018 28th International …, 2018 - ieeexplore.ieee.org
With the gradual deterioration of atmospheric environment, pollution accumulation causes
the increase in flashover accidents, which seriously threatens the safety and stability of power …
the increase in flashover accidents, which seriously threatens the safety and stability of power …
Analysis of factors influencing the internal insulation performance of gis equipment based on multiphysics coupling
K Gao, X Qiao, W Dai, D Ma… - 2018 28th International …, 2018 - ieeexplore.ieee.org
Internal overheating and excessive micro-water content can lead to the degradation of insulation
performance in gas insulated switchgear (GIS) air chamber and cause faults. In order to …
performance in gas insulated switchgear (GIS) air chamber and cause faults. In order to …
Fault Diagnosis of Contaminated Insulators Based on Heterologous Entropy Feature Fusion
K Gao, T Wu, Z Hu, J Deng, D Ma… - 2022 IEEE 5th …, 2022 - ieeexplore.ieee.org
Pollution flashover of insulators is one of the common faults in the field of power transmission
and transformation. In order to improve the reliability of non-contact detection of insulator …
and transformation. In order to improve the reliability of non-contact detection of insulator …