A novel coordinated control strategy for frequency regulation of MMC-HVDC connecting offshore wind farms

S Jiang, H Wang, G Li, Y Xin, L Wang… - IEEE Transactions on …, 2023 - ieeexplore.ieee.org
To solve the problems of weak inertia support and poor frequency regulation capability of
power system, a novel coordinated control strategy for frequency regulation of MMC-HVDC …

A novel DC fault ride-through method for wind farms connected to the grid through bipolar MMC-HVDC transmission

S Jiang, Y Xin, G Li, L Wang - IEEE Transactions on Power …, 2020 - ieeexplore.ieee.org
Modular multilevel converter based high voltage direct current (MMC-HVDC) transmission
is the prospective technology for large-scale wind farms integration. In this paper, a …

Research on frequency stability of power system with high penetration renewable energy: A review

LI Guoqing, LIU Xianchao, XIN Yechun… - High Voltage …, 2024 - epjournal.csee.org.cn
As a key carrier of the" dual-carbon" strategic goal, the power system with high penetration
renewable energy is characterized by low inertia level, poor frequency regulation capability, …

Design of MMC hardware-in-the-loop platform and controller test scheme

G Li, D Zhang, Y Xin, S Jiang… - CPSS Transactions on …, 2019 - ieeexplore.ieee.org
The hardware-in-the-loop (HIL) simulation is an effective method to verify the overall
function of the flexible HVDC transmission control and protection device. With this method, …

Short-circuit current calculation method for FHMMC-HVDC transmission systems with zero DC voltage control

X Yechun, L Yi, J Shouqi, W Weiru… - Power System …, 2022 - epjournal.csee.org.cn
The half and full bridge hybrid modular multilevel converter (FHMMC) limits the DC-side
fault current through the zero-voltage control. To accurately analyse and calculate the post-fault …

Coordinated control strategy of receiving-end fault ride-through for DC grid connected large-scale wind power

S Jiang, Y Xu, G Li, Y Xin… - IEEE Transactions on …, 2021 - ieeexplore.ieee.org
This article proposes a comprehensive coordinated suppression strategy for DC overvoltage
to achieve the receiving-end fault ride-through of DC grid connected large-scale wind power…

AC fault ride-through coordinated control strategy of LCC-MMC hybrid DC transmission system connected to passive networks

Y Xin, W Lou, G Li, S Jiang, T Wang, Y Yang - International Journal of …, 2021 - Elsevier
The LCC-MMC hybrid DC transmission system can combine the economic advantages of LCC
and the technical advantages of MMC, and has broad application prospects for supplying …

[HTML][HTML] Study on multi-type flexible load control method of active distribution network based on dynamic time-sharing electricity price

J Cui, Z Ran, W Shen, Y Xin - Applied Energy, 2024 - Elsevier
Accurate load control is the basis of safe operation and optimal dispatching in active distribution
network, and the demand response system of flexible electricity price mechanism and …

Simplified calculation method of fault current in different topological structures of DC grid considering the influence of transition resistance

X Yechun, L Xin, W Tuo, W Yanxu… - Power System …, 2022 - epjournal.csee.org.cn
Fault current calculation is the basis for equipment selection, parameter designing and
protection setting of DC power grids. However, it is difficult for present methods of fault current …

Feature extraction and classification method for switchgear faults based on sample entropy and cloud model

J Cui, Q Zheng, Y Xin, C Zhou… - IET Generation …, 2017 - Wiley Online Library
This study proposes a fault diagnosis method for extracting and classifying the fault features
of switchgears in accordance with the monitoring data of three‐phase voltage and current, …